FEATURES SPECIFICATIONS FSV-2, FSS, FLY SERIES ULTRASONIC FLOWMETER < > DATA SHEET. Operational specifications. EDSX6-142b. Flow transmitter (FSV S)

Size: px
Start display at page:

Download "FEATURES SPECIFICATIONS FSV-2, FSS, FLY SERIES ULTRASONIC FLOWMETER < > DATA SHEET. Operational specifications. EDSX6-142b. Flow transmitter (FSV S)"

Transcription

1 SERIES ULTRSONI FLOWMETER < > T SHEET FSV-2, FSS, FL This flowmeter is a clamp-on type ultrasonic flow meter based on transit-time measuring method. Making full use of the latest electronics and digital signal processing technologies, we realized a compact and lightweight design, and improved the accuracy and easiness to use while keeping with anti-bubble performance. The communication function (MOBUS: Option) is also applicable. FETURES. High accuracy The flowmeter is designed for high accurary (better than ±.0% of rate) by dynamic correction of fully-developed flow profile. Reynolds Number is calculated and a meter factor (K) is automatically applied for best accuracy at all flow velocities. Further, the adoption of new sound velocity measurement system permits measurements of fluids of unknown sound velocity. Moreover, affection from fluid temperature and pressure is negligible (uto-temp./ Press. compensation). 2. Excellent resistance against aerated flow Fuji s unique BM feature improves measurement reliability for different flow like slurries, sludge, raw sewage and bubble-contained flow (acceptable up to air bubble of 2% volume at m/s velocity). 3. ompact and light-weight Thanks to the adoption of the latest electronics the flow transmitter size and mass are /3 of our traditional instrument. 4. Full variety of sensors The flowmeter can be used with various types of sensors applicable for wide range of pipe size (ø3 to ø6000mm) and fluid temperature (-40 to +200 ). 5. Quick response With the use of high-speed micro-processor suited for digital signal processing, the fast response time is realized. 6. Multi-lingual The following languages are supported for display: Japanese (Katakana), English, German French, and Spanish. 7. Excellent performance and easy operation L and function keys are allowing easy configuration and trouble shooting. L with back light Easy mounting of sensor Extendable rail type detector up to ø50 to ø200mm Trouble shooting Easy operation with keypad on the front surface of the flow transmitter (FSV S) SPEIFITIONS Flow transmitter (FSV S) etector (FSS) etector (FSS) Operational specifications System configuration: Single-path system of a flow transmitter (Model FSV) and a detector (Model FSS) pplicable fluid: Homogenous liquid where the ultrasonic signal can be transmitted Bubble quantity: 0 to 2vol% (for pipe size 50, water, velocity m/s) Fluid turbidity: 0000mg/L max. Type of flow: Fully-developed turbulent or laminar flow in a full-filled pipe Flow velocity range: 0 to ± ±32m/s Power supply: 00 to 240V +0%/-5%, 50/60Hz; or 20 to 30V ESX6-42b ate Oct. 9, 202

2 FSV-2, FSS, FL Signal cable (between detector and converter): oaxial cable (50m max.) applicable up to 300m depending on the condition. Heat resistance: 80 Installation environment: Non-explosive area without direct sunlight, corrosive gas and heat radiation. mbient temperature: Flow transmitter: -20 to +55 etector: -20 to +60 mbient humidity: Flow transmitter: 95%RH max. etector: 90%RH max. Grounding: lass (00 Ω) rrester: as standard at power supply pplicable piping and fluid temperature: <table > etector Type FSS FSS Pipe size (inner diameter) mm ø25 to ø225 mm ø50 to ø200 pplicable pipe material Plastic (PV, etc.) (Note ) Metal pipe (SS, steel pipe, copper pipe, aluminum pipe, etc.) (Note 2) How to mount and judge the pipe diameter V method ø25 to ø225 V method ø50 to ø600 Z method ø600 to ø200 Fluid temperature range -20 to +00 (Note3) -40 to +20 (Note3) Note) Please select the FSS type if following condition. When pipe material is PP or PVF, limit of pipe wall thickness is 5mm or more for PP, 9mm or more for PVF When pipe material is hard to penetrate the ultrasonic wave such as cast-iron pipe, lining pipe and old carbon steel pipe etc.., Llining material is tar epoxy, mortar and rubber etc.. In case lining is removed from the pipe, Measurement can not be conducted Note2) When silicon grease is used as acoustic coupler, Fluid temperature limit is 0 to 60 no matter what detector is selected. Note3) Heat-resistant shock temperature: for 30 minutes at 50 Note4) Please refer to the item 9 for the specification of the special detector (for small diameter pipe,large diameter pipe and high temperature) Performance specifications Rated accuracy: <table 2> etector Type Pipe size (diameter) mm Flow velocity (m/s) ccuracy Plastic pipe Metal pipe FSS ø25 to ø50 2 to 32m/s ±2.0% of rate 0 to 2m/s ±0.04m/s ø50 to ø225 2 to 32m/s ±.0% of rate ±2.0% of rate 0 to 2m/s ±0.02m/s ±0.04m/s FSS ø50 to ø200 2 to 32m/s ±.5% of rate 0 to 2m/s ±0.03m/s ø200 to ø200 2 to 32m/s ±.0% of rate 0 to 2m/s ±0.02m/s Note) Please refer to the item 9 for the specification of the special detector (for small diameter pipe, large diameter pipe and high temperature) Response time: 0.5s (standard mode) 0.2s as selected (quick response mode) Power consumption: 5V max. ( power supply) 6W max. ( power supply) Functional specifications nalog signal: 4 to 20m ( point) Load resistance: 600Ω max. igital output: Forward total, reverse total, alarm, acting range, flow switch, total switch assignable arbitrarily Transistor contact (isolated, open collector) Outputs: 2 points Normal: ON/OFF selectable ontact capacity: 30V, 50m Output frequency: 000P/s max. (pulse width: 5, 0, 50, 00, 200, 500, 000ms) Serial communication (option): RS-485 (MOBUS), isolated, arrester incorporated onnectable quantity: 3 units Baud rate: 9600, 9200, 38400bps Parity: /Odd/Even selectable Stop bits: or 2 bits selectable able length: km max. ata: Flow velocity, flow rate, forward total, reverse total, status, etc. isplay device: 2-color LE (Normal: green, Extraordinary: red) L with 2 lines of 6 characters and back light Indication language: Japanese (Katakana)/English/French/ German/Spanish (changeable) Flow velocity/flow rate indication: Instantaneous flow velocity, instantaneous flow rate indication (minus indication for reverse flow) Numerals: 8 digits (decimal point is counted as digit) Unit: Metric/Inch system selectable Metric system Inch system Velocity m/s ft/s Flow rate L/s, L/min, L/h, L/d, kl/d, gal/s, gal/min, gal/h, gal/d, ML/d, m 3 /s, m 3 /min, m 3 /d, kgal/d, Mgal/d, ft 3 /s, ft 3 / km 3 /d, Mm 3 /d, BBL/s, min, ft 3 /d, Kft 3 /d, Mft 3 /d, BBL/min, BBL/h, BBL/d, BBL/s, BBL/min, BBL/h, kbbl/d, MBBL/d BBL/d, kbbl/d, MBBL/d Note: The gal means USgal. Total indication: Forward or reverse total value indication (negative indication for reverse direction) Numerals: 8 digits (decimal point is counted as digit) Unit: Metric/Inch system selectable Metric system Inch system Total ml, L, m 3, km 3, Mm 3, mbbl, BBL, KBBL gal, kgal, ft 3, kft 3, Mft 3, mbbl, BBL, kbbl, RE-ft onfiguration: Fully configurable from the 4-key pad (ES,,, ENT) Zero adjustment: Set zero/lear available amping: 0 to 00s (every 0.s) for analog output and flow velocity/flow rate indication Low flow rate cutoff: 0 to 5m/s in terms of flow velocity larm: igital output available for Hardware fault or Process fault Burnout: nalog output: Hold/Overscale/Underscale/Zero selectable 2

3 Flow rate total: Hold/ount selectable Burnout timer: 0 to 00s (every s) Bi-directional range: Forward and reverse ranges configurable independently. Hysteresis: 0 to 0% of working range Working range applicable to digital output uto-2 range: 2 forward ranges configurable independently Hysteresis: 0 to 0% of working range Working range applicable to digital output Flow switch: Lower limit, upper limit configurable independently igital output available for status at actuated point Total switch: Forward total switching point configurable igital output available when actuated External total preset: Preset total settable upon contact input setting Backup of power failure: backup by non-volatile memory Physical specifications Type of enclosure: Flow transmitter: FSV S: IP66 FSV H: IP67 (With large L) etector: FSS, FSS: IP65 (When waterproot BN connector is provided) FSS,FSS: IP65 (When water-proof type connector is fitting) FSS (waterproofing): IP68 (submerged resistant structure for 5days) Mounting method: Flow transmitter: Mounted on wall or by 2B pipe etector: lamped on pipe surface coustic coupler: coustic coupler is a filling between detector and pipe. Type of acoustic coupler: <table 3> Type Fluid temperature Teflon piping Silicone rubber (KE-348W) Silicone grease (G40M) Silicone-free grease (HIGH Z) -40 to to to +60 In case of Teflon piping, use grease. Grease for high temperature (KS62M) -30 to +250 Signal cable: Structure: Heat-resisting high-frequency coaxial cable Sheath: Flame-resisting PV Outer diameter: ø7.3mm Terminal treatment <table 5> able type pplicable detector FL FSS, FSS Terminal of flow transmitter side Rod terminal 2 mplifier terminal (M3) Terminal of detector side BN connector mplifier terminal (M4) Please refer to the item 9 for the specification of the special detector * (for small diameter pipe, large diameter pipe and high temperature) imension, Mass: <table 6> Type imensions Mass.(kg) Flow FSV S (IP66) H70 W42 70mm.5 transmitter FSV H (IP67) H277 W244 96mm 4.5 etctor FSS H50 W348 34mm 0.4 FSS H88 W480 53mm Signal cable FL ø7.3mm 90g/m Please refer to the item 9 for the specification of the special detector * (for small diameter pipe, large diameter pipe and high temperature) External terminal of flow transmitter: plug terminal P Loader software as standard ompatible model is P/T compatible instrument. Operation is undefined for P98 series (NE). Main functions: Software for Main unit parameter setting/ change on P OS: Windows 2000/XP or Windows 7 (Home Premium, Professional) Memory requirement: 25MB min. isk unit: -ROM drive compatible with Windows 2000/ XP or Windows 7 (Home Premium, Professional) Hard disk capacity: Minimum vacant capacity of 52MB or more Note: Optional communication board (specified at the 5 th digit of code symbols). Note: ommunication converter For tne P that supports RS-232 serial interface, RS RS-485 converter is needed for connecting the P and main unit. For the P that does not support RS-232 serial interface, additionally, USB - RS232 converter is also needed. <Recommendation> [RS RS-485 converter] R-770X(manufactured by SSMEX R) [USB - RS-232 converter] USB-VRS9 (manufactured by SNW SUPPL) Material: Flow transmitter: luminum alloy etector: <table 4> etector Type Sensor housing Guide rail FSS PBT SUS304 FSS PBT luminum alloy Please refer to the item 9 for the specification of the special detector * (for small diameter pipe, large diameter pipe and high temperature) 3

4 FSV-2, FSS, FL MESURING PRINIPLE With ultrasonic pulses propagated diagonally between the upstream and downstream sensors, flow rate is measured by detecting the time difference obtained by the flow of fluid. etector θ Flow velocity Upstream sensor ownstream sensor Output signal t t 2 Flow transmitter ONFIGURTION IGRM () Single-path system (V method) etector Signal able Flow transmitter (2) Single path system (Z method) 4 to 20m igital signal (Up to 2 point) MOUNTING OF ETETOR Ultra sonic oscillator Plastic wedge Pipe Lining etector Signal able Flow transmitter 4 to 20m igital signal (Up to 2 point) onditions on straight pipe ( : Inside diameter of pipe) lassification Upstream side ownstream side L 5 90 bend 0 or more L 0 etector Tee 0 or more L 50 L 0 0 or more 0.5 or more L 30 L 5 iffuser.5 L 0 L 50 Reducer L 30 L 0 Various Valve Pump In case that flow control valve exists on upstream side. Stop valve heck valve P In case that flow control valve exists on downstream side. L 50 (Note) The source : JEMIS-032 4

5 OE SMBOL <Flow transmitter> F S V 2 escription E 4 S H B B (estination) (4th digit) Standard (English) (ommunication) (5th digit) RS485 (Use) (6th digit) Single measuring path (Power supply) (7th digit) 00 to 240V 50/60Hz 20 to 30V (ase structure) (9th digit) IP66 IP67 (Wire connection port) (0th digit) Weatherproof gland provided [G/2 and G3/8 (internal threads)] Union (for pilica) with gland [G/2 female screw] (when "H" is specified 9th digit) (ombination with explosion-proof detector) (th digit) (Parameter setting) (2th digit) Setting provided Setting provided + tag Tag (Mounting method) (3th digit) Pipe mount (if the 9th digit is S) Wall mount Pipe mount (if the 9th digit is H) <etector> F S S B escription <Senser type>(4th digits) ø50 to ø200mm <Guide rail>(5th digits) (Extendable rail type) <Mounting belt>(6th digits) *2 Stainless belt (.0m 2) SS belt fasten with screws (.0m 4) Wire ø500mm <coustic coupler> (7th digit) Silicon rubber (KE348) Silicone-free grease (HIGH-Z) Silicone grease (G40M) <Watwe-proof treatment>(9th digit) (with signal cable 0m) <Tag plate> (0th digit) *2) Please refer to the table 8 to serect the mounting belt at 6th digits. [Table 8] How to select at 6th digits. Mounting method ø300mm ø600mm ø200mm V method or Z method Explanation of the extendable rail type detector Unextended condition <etector> F S S B escription <Senser type> (4th digits) ø25 to ø225mm (V method) <Guide rall> (5th digits) <Mounting belt> (6th digits) Stainless belt (.0m 2) <coustic coupler> (7th digit) (Note 2) Sillicon rubber Sillicon-free grease Silicon grease - <Tag plate> (0th digit) available pipe diameter up to ø50 to ø300mm <V method> Extended condition available pipe diameter up to ø600mm <V method> Installation of the supplied rail end. Note : Normally select silicone rubber as acoustic coupler. Silicone rubber in tube (00g) is furnished. If you place an order for several units, tube may suffice for every 5 units. Select silicone-free grease for semiconductor manufacturing equipment or the like that is vulnerable to silicone. The silicone-free grease is water-soluble and, therefore, cannot be used in environment exposed to water or on piping subjected to a condensation. Since the grease does not set, a periodic maintenance (cleaning, refilling every about 6 months at normal temperature) is necessary. available pipe diameter up to ø200mm <Z method> Belt appearance for attachment of the detector. Stainless belt SS belt fasten with screws wire 5

6 FSV-2, FSS, FL F L escription Z Z Z Type of sensor (4th digit) for FSS, FSS, FSS, FSSH able length (5,6 and 7th digit) 5 m 0 m 5 m 20 m 25 m 30 m 35 m 40 m 45 m 50 m 55 m 60 m 65 m 70 m 75 m 80 m 85 m 90 m 95 m 00 m 0 m 20 m 30 m 40 m 50 m Others (contact us) Note) When detector is FSS, length of signal cable is up to 60m. 6

7 ES ENT Ultrasonic Flow Meter OUTLINE IGRM (Unit:mm) U bolt (M8) (option) Mtg. plate Mtg. hole U bolt (M8) (option) Mtg. holes2-ø (233) TIME ELT- 25 Mtg. pipe SS tag (option) able gland Earth terminal (M4) 53 Bracket (option) Mtg. pipe Earth terminal (M4) For sensor cable (PF3/8) For power supply & output cable (PG3.5) Flow transmitter : FSV S (IP66) 39 For power supply & output cable (PF/2) Flow transmitter : FSV H (IP67) For sensor cable (PF/2) 480 ±2 SPING: 0 to 300 SS tag (option) inch mm 348 mm inch 30 (50) Scale (inch) BN ONN. Scale (mm) Lock nut 53 Sensor 54 88max. BN connector Frame Lock clip Rail end Tag plate Name plate Extended rail <Shipment style (V method)> Guide rail (880) Spacing (djustable every 3mm) 700max. 400max. 240 mm inch mm inch etecter : Type FSS Extended rail <Extended style (Longest, V method)> 5.5 ø3.2 L (cable length (m) : specified by order) ø7.3 ø Bar terminal To Flow transmitter To etector Signal cable : Type FL ø4.5 BN connector Rail end (ccessories) <Sepalate style (Z method)> etecter : Type FSS 7

8 FSV-2, FSS, FL ONNETION IGRM <Flow transmitter> <etector> Earth terminal (M4) power supply power supply Option L N FG + FG SG 2 3 B+ G + 00 to 240V 50/60Hz 20 to 30V RS-485 To flow transmitter GN 8 HF 9 0 GN HF2 O TR out O2 TR out Max. 30V, 50m I out SH SH To downstream-side sensor To upstream-side sensor Usable wiring material Wire Gauge: WG20 (0.5mm 2 ) to WG6 (.5mm 2 ) Strip-off length: 0mm WG20 to WG6 0mm Bar terminal Weidmüller 0 ø to.7 SOPE OF ELIVER 6 Flow transmitter (provided with U-bolt and nuts for pipe mount) etector (provided with mounting fixture and acoustic coupler) * The acoustic coupler is option for popular type detectors. Signal cable -ROM (contains instruction manual, loader software) ITEMS ESIGNTE ORERING ø2.6 to 3.5. etector code symbols 2. Flow transmitter code symbols 3. Signal cable code symbols 4. Tag No. as necessary 5. If parameter setting is specified, send back the attached parameter specification table duly filled. OPTIONL ESSORIES Name rawing No. Silicone grease (G40M) ZZP*4523N5 2 Silicone rubber (KE348W) ZZP*45735N2 3 Silicone-free grease (HIGH-Z) ZZP*TK7M098P hecked items before purchase Following conditions may cause failure of the measurement or to reduce the accuracy by this flow meter. Please consult and ask Fuji Electric for checking with actual equipment previously if you have hard to judge the appropriate application. )Fluid If fluid contains a large amount of bubbles (approx. 2vol% or more at m/s flow rate) If fluid has bad turbidity 0000(mg/L) or more, If fluid contains slurry or solid materials (about 5wt%) If flow rate is low Reynolds No.0000 or less, (reference: flow rate 5m 3 /h with ø00mm) If it is circulating oil, liquid medicine of low concentration, waste liquid and hot spring, 2)Pipe If inside pipe is rusty carbon steel pipe, If inside pipe having adhering substances and sediment If outer surface of cast-iron pipe is rough, If pipe wall is tick such as ruinous pipe, (PP material 5mm or more, PVF material 9mm or more) If it is SGPW pipe, If lining pipe is removed from pipe, If it is rubber pipe, 3) Length of the straight pipe For accurate measurement, straight pipes are needed between up and down stream side of the measuring part. Please meet the straight pipe conditions according item4. aution on use ) o not damage the sensor or signal mounted on the pipe. 2) Make sure to fill the fluid inside the pipe to measure. 3) When you use horizontal pipe, it is recommended to install the sensor horizontally. 4) When you use the grease as acoustic coupler to install the sensor for outdoor use, it is recommended to install the waterproof cover to prevent from the degradation. 8

9 etector for special application ) detector for small diameter type Pipe size: ø3 to 00mm Fluid temperature: -40 to 00 Type: FSS - Specification Sensor frequency: 2MHz Mounting method: V method Fluid temperature: -40 to 00 pplicable pipe material: PV, SS, carbon steel pipe, copper pipe, aluminum pipe, etc. [In case lining is removed from the pipe, Measurement can not be conducted] Rated accuracy of combination with the flow transmitter (pplicable piping: plastic, metal pipe) Internal diameter Velocity ccuracy (mm) ø3 ø50 2 to 32m/s ±.5% to ±2.5% of rate 0 to 2m/s ±0.03 to ±0.05m/s ø50 ø00 2 to 32m/s ±.0% of rate 0 to 2m/s ±0.02m/s Mounting belt: according to specified code of symbol. Material: PBT, guide rail: aluminum alloy + plastic Type of enclosure: IP52 coustic coupler: according to specified code of symbol. Mass: 0.6kg OE SMBOL <etector> F S S B escription <Senser type>(4th digits) ø3 to ø00mm <Guide rail>(5th digits) <Mounting belt>(6th digits) Stainless belt (.0m 2) SS belt fasten with screws (.0m 4) <coustic coupler> (7th digit) Silicon rubber (KE348) Silicone-free grease (HIGH-Z) Silicone grease (G40M) <Watwe-proof treatment>(9th digit) <Tag plate> (0th digit) 5.5 OPTIONL ESSORIES Name Sillicon grease (GM40M) Sillicon rubber (KE348W) Sillicon-free grease (HIGH-Z) OUTLINE IGRM (unit: mm) <etector> ø3.2 istance between two sensors 0 to 33 Scale (inch) ursor inch mm 52.5 Scale (mm) 90 max. onnector Lock nut Element holder Small diameter sensor: FSS L (cable length (m) : specified by order) ø7.3 rawing No. ZZP*4523N5 ZZP*45735N2 ZZP*TK7M098P Saddle ø F L escription Z Z Z Type of sensor (4th digit) for FSS, FSS, FSSH, FSS able length (5,6 and 7th digit) 5 m 0 m 5 m 20 m 25 m 30 m 35 m 40 m 45 m 50 m 55 m 60 m 65 m 70 m 75 m 80 m 85 m 90 m 95 m 00 m 0 m 20 m 30 m 40 m 50 m Others (contact us) Scope of delivery etector, acoustic coupler and set of the mounting belt according to specified code of symbol Signal cable according to specified code of symbol 30 Bar terminal To Flow transmitter To etector Signal cable : FL ø4.5 BN connector 9

10 FSV-2, FSS, FL etector for special application 2) detector for high temperature Pipe size: ø50 to 400mm Fluid temperature: -40 to 200 Type: FSSH - Specification Sensor frequency: 2MHz Mounting method: V method (ø50 to 250mm) or Z method (ø50 to 400mm) Fluid temperature: -40 to 200 pplicable pipe material: PV, SS, carbon steel pipe, copper pipe, aluminum pipe,etc. [In case lining is removed from the pipe, Measurement can not be conducted] Rated accuracy of combination with the flow transmitter (pplicable piping: plastic,metal pipe) Internal diameter Velocity ccuracy (mm) ø50 ø300 2 to 32m/s ±.0% of rate 0 to 2m/s ±0.02m/s ø300 ø to 32m/s ±.0% of rate 0 to 0.75m/s ±0.0075m/s Mounting belt: according to specified code of symbol. Material: sensor housing: SUS304 guide rail: SUS304 + aluminum alloy Type of enclosure: IP52 coustic coupler: according to specified code of symbol. Mass:.6kg OPTIONL ESSORIES Name Guide rail for high-temperature sensor (Z method) High-temperature grease(ks62m) OUTLINE IGRM (unit: mm) <etector> Scale(inch) istance between two sensors 0 to 330 onnector Scale(mm) Saddle Name plate Lock nut rawing No. ZZP*TK4J5973 ZZP*TK7G ±2 OE SMBOL <etector> F S S H H escription <Senser type>(4th digits) ø50 to ø400mm (-40 to 200 ) <Guide rail>(5th digits) <Mounting belt>(6th digits) Stainless belt (.0m 2) SS belt fasten with screws (.0m 4) <coustic coupler> (7th digit) High-temperature grease (KS62M) <Watwe-proof treatment>(9th digit) <Tag plate> (0th digit) F L escription Type of sensor (4th digit) for FSS, FSS, FSSH, FSS Z Z Z able length (5,6 and 7th digit) 5 m 0 m 5 m 20 m 25 m 30 m 35 m 40 m 45 m 50 m 55 m 60 m 65 m 70 m 75 m 80 m 85 m 90 m 95 m 00 m 0 m 20 m 30 m 40 m 50 m Others (contact us) ø26 ursor Element holder 33±0.5 90max. 205max. Scope of delivery etector, acoustic coupler and set of the mounting belt according to specified code of symbol Signal cable according to specified code of symbol L (cable length (m) : specified by order) 44± 5.5 ø3.2 ø7.3 ø 0 High-temperature sensor: FSSH 30 Bar terminal To Flow transmitter To etector Signal cable : FL ø4.5 BN connector

11 etector for special application 3) detector for large diameter type Pipe size: ø200 to 6000mm Fluid temperature: -40 to 80 Type: FSSE - Specification Sensor frequency: 0.5MHz Mounting method: V or Z method Fluid temperature: -40 to 80 pplicable pipe material: PV, SS, carbon steel pipe, copper pipe, aluminum pipe,etc. In case lining is removed from the pipe, Measurement * can not be conducted lso applicable to water-proof type according to specified code of symbol (submerged resistant structure for 5days including 0m cable) Rated accuracy of combination with the flow transmitter (pplicable piping: plastic, metal pipe) Internal diameter Velocity ccuracy (mm) ø200 ø300 2 to 32m/s ±.5% of rate 0 to 2m/s ±0.03m/s ø300 ø to 32m/s ±.5% of rate 0 to 0.75m/s ±0.03m/s ø000 ø6000 to 32m/s ±.0% of rate 0 to m/s ±0.02m/s Mounting belt: according to specified code of symbol. Material: Sensor housing PBT, Sensor cover SUS304 Type of enclosure: IP67 (silicon rubber is filled up on the terminal block when connecting work) coustic coupler: according to specified code of symbol. Mass:.2kg OPTIONL ESSORIES Name Wire rope for mounting the sensor Spring Wire rope (up to ø500mm) Wire rope (up to ø000mm) Wire rope (up to ø500mm) Wire rope (up to ø3000mm) Wire rope (up to ø6000mm) Sillicon grease (GM40M) Sillicon rubber (KE348W) Sillicon-free grease (HIGH-Z) OUTLINE IGRM (unit: mm) <etector> Name plate rawing No. ZZP*TK745007P ZZP*TK ZZP*TK ZZP*TK ZZP*TK ZZP*TK ZZP*4523N5 ZZP*45735N2 ZZP*TK7M098P OE SMBOL <etector> F S S E E E B escription <Senser type>(4th digits) ø200 to ø6000mm <Guide rail>(5th digits) <Mounting belt>(6th digits) Wire ø500mm Wire ø6000mm <coustic coupler> (7th digit) Silicon rubber (KE348) Silicone-free grease (HIGH-Z) Silicone grease (G40M) <Watwe-proof treatment>(9th digit) (with signal cable 0m) <Tag plate> (0th digit) F L escription Type of sensor (4th digit) for FSSE Z Z Z able length (5,6 and 7th digit) 5 m 0 m 5 m 20 m 25 m 30 m 35 m 40 m 45 m 50 m 55 m 60 m 65 m 70 m 75 m 80 m 85 m 90 m 95 m 00 m 0 m 20 m 30 m 40 m 50 m Others (contact us) 78± Sensor ø3.2 L (cable length (m) : specified by order) ø7.3 ø 84± 67± 4 Wire rope Mounting spring Scope of delivery etector, acoustic coupler and set of the mounting belt according to specified code of symbol Signal cable according to specified code of symbol ø9 5.5 Large sensor: FSSE Bar terminal To Flow transmitter Signal cable : FL 30 To etector 3-ø4.3 8

12 FSV-2, FSS, FL <Parameter specification table> Setting item Initial value Setting value Setting item Initial value Setting value I No 0000 Total mode Stop Language English Total rate 0m 3 System unit Metric Total preset 0m 3 Flow unit m 3 /h Pulse width 50.0msec Total unit m 3 Burnout (total) Hold Outer diameter 60.00mm Burnout timer 0sec Pipe material PV pipe O output type (Note ) Not used Wall thickness 4.00mm O output actuation ON when actuated Lining material Without lining O2 output type Not used Lining thickness O2 output actuation ON when actuated Kind of fluid Water Operation mode Standard Viscosity m 2 /s Sensor mount V metod Sensor type FSS amping 5.0sec ommunication mode RS-485 ut off 0.50m 3 /h Baud rate 9600bps st line Flow velocity (m/s) Parity Odd st line decimal point position ****.*** Stop bit bit 2nd line Flow rate (m 3 /h) Station No. 2nd line decimal point position ****.*** Range kind Flow rate Range type Single range Full scale 5.000m 3 /h Full scale m 3 /h Range HS. 0.00% Burnout (current) Hold Burnout timer 0sec Output low limit -20% Output high limit 20% Rate limit 0.000m 3 /h Rate limit timer 0sec Measuring conditions Output conditions isplay nalog output Note: When total pulse output has been selected for O, O2 specify total pulse value and total pulse width so that conditions and 2 shown below are satisfies. ommunication Output conditions Total output ondition : Flow span-*[m 3 /s] total pulse value*[m 3 ] 00[Hz] ondition 2 : Flow span-*[m 3 /s] total pulse value*[m 3 ] total pulse width [ms] * In the case of 2 ranges, perform calculations using either flow span- or flow span-2, whichever is greater. aution on Safety *Before using this product, be sure to read its instruction manual in advance. International Sales iv Sales Group Gate ity Ohsaki, East Tower, -2, Osaki -chome, Shinagawa-ku, Tokyo , Japan Phone: , 728 Fax: Information in this catalog is subject to change without notice. Printed in Japan

SERIES ULTRASONIC FLOWMETER

SERIES ULTRASONIC FLOWMETER SERIES ULTRSONIC FLOWMETER < M-Flow PW > DT SHEET FLR-3, FSS, FL This flowmeter is a clamp-on type ultrasonic flow meter based on transit-time measuring method. Making full use of the latest electrics

More information

SERIES ULTRASONIC FLOWMETER

SERIES ULTRASONIC FLOWMETER SERIES ULTRSONIC FLOWMETER < M-Flow PW > DT SHEET FLR-3, FSS/FLS/FL This flowmeter is a clamp-on type ultrasonic flow meter based on transit-time measuring method. Making full use of the latest electrics

More information

ULTRASONIC FLOWMETER <

ULTRASONIC FLOWMETER < ULTRASONIC FLOWMETER < DATA EET F (Flexible Type)> FLH, FLW, FLD 1 SERIES This flowmeter is a fixed type ultrasonic flowmeter based on transit-time measuring method. Thanks to micro-processor based electronics,

More information

ULTRASONIC FLOWMETER < >

ULTRASONIC FLOWMETER < > SERIES ULTRSONI FLOWMETER < > DT SHEET FS, FLS/FSG/FSD This flowmeter is a clamp-on type ultrasonic flow meter based on transit-time measuring method. Making full use of the latest electronics and digital

More information

ULTRASONIC FLOWMETER < >

ULTRASONIC FLOWMETER < > SERIES ULTRSONIC FLOWMETER < > DT SHEET FS, FLS/FLW/FLD This flowmeter is a clamp-on type ultrasonic flow meter based on transit-time measuring method. Making full use of the latest electronics and digital

More information

Applicable pipe diameter is 13mm to 6000mm

Applicable pipe diameter is 13mm to 6000mm TIME DELTA-C Applicable pipe diameter is 13mm to 6000mm High accuracy measurement of fluid flow rate: 1.0% of rate Quick response: 0.2 sec. or less (quick response mode) Minimal Influence by the pressure

More information

PORTABLE TYPE ULTRASONIC FLOWMETER

PORTABLE TYPE ULTRASONIC FLOWMETER PORTABLE TYPE ULTRASONIC FLOWMETER DATA SHEET FLC...2, FLD PORTAFLOW-X is a portable type ultrasonic flowmeter utilizing transit time difference for measuring flow rates in pipes from the outside. It is

More information

ULTRASONIC FLOWMETER TIME DELTA-C

ULTRASONIC FLOWMETER TIME DELTA-C Fuji Instrumentation & Control ULTRASONIC FLOWMETER TIME DELTA-C The latest advance in high performance transit time flow measurement Superior signal processing and best-in-class anti-bubble performance

More information

PORTABLE TYPE ULTRASONIC FLOWMETER

PORTABLE TYPE ULTRASONIC FLOWMETER PORTABLE TYPE ULTRASONIC FLOWMETER DATA SHEET FLC...2, FLD PORTAFLOW-X is a portable type ultrasonic flowmeter utilizing transit time difference for measuring flow rates in pipes from the outside. It is

More information

ULTRASONIC FLOWMETER < S (Standard Type)> DATA SHEET

ULTRASONIC FLOWMETER < S (Standard Type)> DATA SHEET SERIES ULTRASONIC FLOWMETER < S (Standard Type)> DATA EET This flowmeter is a clamp-on type ultrasonic flowmeter based on transit-time measuring method. Thanks to microprocessor based electronics, the

More information

Time Delta S Fixed Transit-Time Flow Meter System

Time Delta S Fixed Transit-Time Flow Meter System Fixed Transit-Time Flow Meter System Key Features Dynamic flow correction Simple configuration Digital outputs Enhanced anti-bubble measurement technology (ABM) Rugged and reliable Maintenance free The

More information

PORTABLE TYPE ULTRASONIC FLOWMETER (PORTAFLOW-C)

PORTABLE TYPE ULTRASONIC FLOWMETER (PORTAFLOW-C) PORTBLE TPE ULTRSONI FLOWMETER (PORTFLOW-) DT SHEET PORTFLOW- is a portable type ultrasonic flowmeter utilizing the transit time measuring method, using a clampon type detector. It is a compact and lightweight

More information

UL350 ULTRASONIC FLOWMETER CLAMP-ON TYPE OUTLINE FEATURES MEASUREMENT PRINCIPLE

UL350 ULTRASONIC FLOWMETER CLAMP-ON TYPE OUTLINE FEATURES MEASUREMENT PRINCIPLE CLMP-ON TYPE UL350 ULTRSONIC FLOWMETER OUTLINE Our clamp-on type Ultrasonic Flowmeter UL350 has enabled applications to piping in various kinds by enhancing the permeation property of ultrasonic wave.

More information

Ultrasonic Flowmeters

Ultrasonic Flowmeters Ultrasonic Flowmeters For Liquids and for Air From Air to Oil Reliable Flow Measurement 21A1-E-0006a Innovative Solutions for Various Applications Spool Piece Ultrasonic Flowmeter for Liquids High accuracy:

More information

Instruction Manual ULTRASONIC FLOWMETER TYPE: UXF1 SX1, PSX2 ULTRASONIC FLOW METER. Dwyer Instruments, Inc. Bulletin F-69

Instruction Manual ULTRASONIC FLOWMETER TYPE: UXF1 SX1, PSX2 ULTRASONIC FLOW METER. Dwyer Instruments, Inc. Bulletin F-69 Instruction Manual ULTRASONIC FLOWMETER TYPE: UXF1 SX1, PSX2 ULTRASONIC FLOW METER Dwyer Instruments, Inc. Bulletin F-69 PREFACE We are grateful for your purchase of Dwyer Instruments ultrasonic flowmeter

More information

ULTRASONIC FLOWMETER M-Flow

ULTRASONIC FLOWMETER M-Flow Instruction Manual ULTRASONIC FLOWMETER M-Flow TYPE: FLR (Converter) FLS (Detector) FLY (Signal cable) PREFACE We thank you very much for purchasing Fuji s ultrasonic flowmeter. The instruction manual

More information

Series TFXL ULTRASONIC CLAMP-ON FLOW METER DIMENSIONAL SPECIFICATIONS PRODUCT INSTALLATION

Series TFXL ULTRASONIC CLAMP-ON FLOW METER DIMENSIONAL SPECIFICATIONS PRODUCT INSTALLATION Series PROUT INSTLLTION Series IMENSIONL SPEIFITIONS MEHNIL IMENSIONS: INHES (MM) Installation onsiderations 1. Select the optimum mounting location on the piping system a full pipe with at least 10 straight

More information

UL6300 SONICMAX. Ultrasonic Clamp-on Flowmeter OUTLINE FEATURES STANDARD SPECIFICATION. Common specification

UL6300 SONICMAX. Ultrasonic Clamp-on Flowmeter OUTLINE FEATURES STANDARD SPECIFICATION. Common specification SONICMAX UL63 Ultrasonic Clamp-on Flowmeter OUTLINE SONICMAX UL63 is the ultrasonic flowmeter of the time flight system which combined the highly efficient converter (UFC3) with the clamp-on sensor (UFS6).

More information

HTTF Transit Time Ultrasonic Flow Meter

HTTF Transit Time Ultrasonic Flow Meter Installation onsiderations imensional Specifications 1. Select the optimum mounting location on the piping system a full pipe with at least 10 straight pipe diameters upstream and 5 pipe diameters downstream

More information

UL6300 SONICMAX. Ultrasonic Clamp-on Flowmeter OUTLINE FEATURES MEASURING PRINCIPLE

UL6300 SONICMAX. Ultrasonic Clamp-on Flowmeter OUTLINE FEATURES MEASURING PRINCIPLE SONICMAX UL63 Ultrasonic Clamp-on Flowmeter OUTLINE SONICMAX UL63 is the ultrasonic flowmeter of the time flight system which combined the highly efficient converter (UFC3) with the clamp-on sensor (UFS6).

More information

EGM1100C MAGMAX. Compact Electromagnetic Flowmeter GENERAL FEATURES STANDARD SPECIFICATION. General Specification

EGM1100C MAGMAX. Compact Electromagnetic Flowmeter GENERAL FEATURES STANDARD SPECIFICATION. General Specification EGMC Compact Electromagnetic Flowmeter GENERA MAGMAX EGMC is the compact type electromagnetic flowmeter with a converter EGC mounted integrally on a primary head EGS lined with fluorocarbon resin PFA.

More information

Ultrasonic Flowmeters

Ultrasonic Flowmeters Ultrasonic Flowmeters For Liquids and for Air From Air to Oil Reliable Flow Measurement 21A1-E-0006 Innovative Solutions for Various Applications Spool Piece Ultrasonic Flowmeter for Liquids High accuracy:

More information

Flow Measurement. SITRANS F US Clamp-on. SITRANS FUP1010 (Portable) 4/318 Siemens FI Overview

Flow Measurement. SITRANS F US Clamp-on. SITRANS FUP1010 (Portable) 4/318 Siemens FI Overview Flow Measurement SITRNS F US lamp-on Siemens G 2011 Overview SITRNS FUP1010 clamp-on non-intrusive ultrasonic flow transmitter offers maximum versatility plus battery power for portable field use. It can

More information

Portable Transit Time Flow Meter for Accurate Flow Measurement from Outside a Pipe

Portable Transit Time Flow Meter for Accurate Flow Measurement from Outside a Pipe Portable Transit Time Flow Meter for Accurate Flow Measurement from Outside a Pipe Portable Ultrasonic Flowmeters Models PT400 & PT500 Measure Flow of Clean Fluids in Full Pipes with Non-contacting Ultrasonic

More information

FLS F6.60 MAGMETER FLOW SENSOR INSERTION FLOW SENSORS APPLICATIONS MAIN FEATURES

FLS F6.60 MAGMETER FLOW SENSOR INSERTION FLOW SENSORS APPLICATIONS MAIN FEATURES FLS F6.60 MAGMETER FLOW SENSOR The new F6.60 and F6.63 are flow meters without moving mechanical parts which can be applied for the measurement of dirty liquids so long as they are conductive and homogeneous.

More information

NCM-603 Hand Held Clamp-on Ultrasonic Transit Time Flowmeter

NCM-603 Hand Held Clamp-on Ultrasonic Transit Time Flowmeter NCM-603 Hand Held Clamp-on Ultrasonic Transit Time Flowmeter Quick Start - Operation Manual Rev 10.01.08 This Quick Start is provided solely to help you get the flowmeter up and running as quickly as possible.

More information

FLOWX3 F3.60M.S Insertion Magmeter

FLOWX3 F3.60M.S Insertion Magmeter FLOWX3 F3.60M.S Insertion Magmeter The FLOWX3 F3.60M.S Insertion Magmeters are suitable to measure flowrate in both metal and thermoplastic pipelines. No moving mechanical parts and the high quality materials

More information

CZ-200P PG500 PCT-300. General Description. Features. Resin Pressure Measuring System CZ-200P. Resin Pressure Sensor CZ-200P

CZ-200P PG500 PCT-300. General Description. Features. Resin Pressure Measuring System CZ-200P. Resin Pressure Sensor CZ-200P 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 P5 P5 5 Resin Pressure Measuring System Z-2P Z-2P P5 PT-3 eneral escription Resin pressure indicator P5 Resin pressure sensor : Z-2P Output converter : PT-3 RK's resin pressure

More information

EASZ-10P Operating Instructions

EASZ-10P Operating Instructions 219 East Main Street Mechanicsburg, PA, USA 17055 Toll Free: 866-EESIFLO Fax: (717) 697-2122 EASZ-10P Operating Instructions Introduction... 2 Sensor Mounting... 2 Keypad.. 4 Battery... 4 Menu System.

More information

HENRI Flowmeter for Pulp Slurry

HENRI Flowmeter for Pulp Slurry MagneW 3000 PLUS Smart Electromagnetic Flowmeter HENRI Flowmeter for Pulp Slurry Model MGH14 (onverter) / MGH18 (Detector) OVERVIEW The MagneW 3000 PLUS HENRI (High-Energy Noise-Resistant Instrument) flowmeter

More information

2-Color Display Digital Flow Switch

2-Color Display Digital Flow Switch -Color Display Digital Flow Switch Series Flow rate range:, 5, 5, l/min. Minimum unit setting:. l/min. (. l/min when the flow rate range is 5, 5, l/min.) Repeatability: ±%F.S. or less Grease-free Flow

More information

SITRANS F flowmeters SITRANS F US. SITRANS FUT1010 Ultrasonic flowmeter. Overview. Application

SITRANS F flowmeters SITRANS F US. SITRANS FUT1010 Ultrasonic flowmeter. Overview. Application Overview SITRANS F flowmeters Application Liquid applications Gas applications Pipelines Custody transfer, allocation, Upstream Production wells, line balance, gathering, separation interface/densitometer

More information

Flow Measurement SITRANS F US Clamp-on

Flow Measurement SITRANS F US Clamp-on Siemens G 2017 SITRS US lamp-on Overview SITRS U1010 clamp-on non-intrusive ultrasonic flow transmitter offers maximum versatility plus battery power for portable field use. It can operate in either Wideeam

More information

ecotrans Lf 01/02 Microprocessor Transmitter / Switching Device for Conductivity

ecotrans Lf 01/02 Microprocessor Transmitter / Switching Device for Conductivity Data Sheet 20.27 Page / ecotrans Lf 0/02 Microprocessor Transmitter / Switching Device for Conductivity Type 2027 Housing for DIN rail mounting (5 x 7.5 mm to EN 0 75 A.) Brief description The JUMO ecotrans

More information

Flow Measurement SITRANS F S Clamp-on

Flow Measurement SITRANS F S Clamp-on Function Operating Principle The SITRANS F S system is a transit-time ultrasonic meter that provides exceptional performance using a non-intrusive clampon approach. Ultrasonic sensors transmit and receive

More information

Zirconia Oxygen Gas Analyzers

Zirconia Oxygen Gas Analyzers Direct insertion type Zirconia Oxygen Gas nalyzers Detector type: ZFK8 / onverter type: ZKM ZKM ZKM ZKM ZFK8 ZFK8 Modular detector design allows easy field replacement of zirconia element nhanced safety

More information

The Multivariable Air Flow Meter

The Multivariable Air Flow Meter The Multivariable Air Flow Meter Model MVC10A/MVC10F OVERVIEW The Multivariable Mass Flow Meter model MVC10A/ MVC10F, a compact has all function necessary to measure nitrogen (N 2 ) gas, carbon dioxcide

More information

INDEX. Introduction. Introduction. Sensor Mounting. Keypad System. Battery. Menu System. Error/Warning Messages. Troubleshooting guide

INDEX. Introduction. Introduction. Sensor Mounting. Keypad System. Battery. Menu System. Error/Warning Messages. Troubleshooting guide Measuring Flow Worldwide INDEX Introduction Sensor Mounting Keypad System Battery Menu System Error/Warning Messages Troubleshooting guide Questions and Answers Introduction The EASZ-10P Flow Meter measures

More information

Portable Ultrasonic Flow Measuring System prosonic flow 92

Portable Ultrasonic Flow Measuring System prosonic flow 92 Technical Information TI 060D/24/ae Portable Ultrasonic Flow Measuring System prosonic flow 92 Temporary volume flow measurement of liquids with Clamp On sensors Features and benefits Portable transmitter,

More information

EGM5300C MAGMAX. Compact Electromagnetic Flowmeter GENERAL FEATURES STANDARD SPECIFICATION. General Specification

EGM5300C MAGMAX. Compact Electromagnetic Flowmeter GENERAL FEATURES STANDARD SPECIFICATION. General Specification MAGMAX EGM53C Compact Electromagnetic Flowmeter GENERAL MAGMAX EGM53C is a combination of EGS5 primary head with Ceramic measuring tube and high performance converter EGC3. EGM53C with high durability

More information

The Multivariable Air Flow Meter

The Multivariable Air Flow Meter No. SS2-MVC200-0100 OVERVIEW The Multivariable Mass Flow Meter AIRcube, a compact has all function necessary to measure nitrogen (N 2 ) gas, carbon dioxcide (CO 2 ) gas and air. The model MVC10A/MVC10F

More information

ph Analyzer (4-wire system transmitter) ORP Analyzer (4-wire system transmitter)

ph Analyzer (4-wire system transmitter) ORP Analyzer (4-wire system transmitter) ph nalyzer (4-wire system transmitter) ORP nalyzer (4-wire system transmitter) HM-6 HM-6 The HM-6/HM-6 is a field installation type ph/orp analyzer (transmitter) that is housed in a robust, die-cast aluminum

More information

Three types of flow range. 0.4 to 4 L/min (PF2D504) 1.8 to 20 L/min (PF2D520) 4.0 to 40 L/min (PF2D540) Swept flow characteristics (reference)

Three types of flow range. 0.4 to 4 L/min (PF2D504) 1.8 to 20 L/min (PF2D520) 4.0 to 40 L/min (PF2D540) Swept flow characteristics (reference) Digital Flow Switch for Deionized Water and Chemical Liquids PFD Series RoHS single controller can monitor the flow rate of different sensors. Body and New PF Tube Super PF Dust generation of particles/cc

More information

SS Concentration Analyzer

SS Concentration Analyzer SS Concentration nalyzer Model : SSD-6 (for Low Concentration Measurement) SSD-6 (for Medium Concentration Measurement) n SS concentration analyzer is an optically based measurement instrument for continuously

More information

tekson TS Series Low Cost Ultrasonic Water Energy Flow Measurement

tekson TS Series Low Cost Ultrasonic Water Energy Flow Measurement Sensing the pulse of industry tekson TS Series Low Cost Ultrasonic Water Energy Flow Measurement tekflo sensors are proud to present their tekson TS Series ultrasonic water energy meter, which uniquely

More information

Spiraflo Steam flowmeters

Spiraflo Steam flowmeters Spiraflo Steam flowmeters Using a Spiraflo steam meter from Spirax Sarco will enable you to measure steam use accurately under all load conditions. It will provide vital information on usage and associated

More information

FH8500. Metering Solution for Custody Transfer Applications. One Step Ahead in Ultrasonic Flowmetering. Main Applications

FH8500. Metering Solution for Custody Transfer Applications. One Step Ahead in Ultrasonic Flowmetering. Main Applications FH85 Metering Solution for Custody Transfer Applications One Step Ahead in Ultrasonic Flowmetering Main Applications Oil Production & Allocation FSO, FPSO Metering Tanker Off-loading Storage Management

More information

Ultrasonic Flowmeter. M-1500 Plus Non-invasive Inline DSP Ultrasonic Flowmeter. Operating Principle. Features

Ultrasonic Flowmeter. M-1500 Plus Non-invasive Inline DSP Ultrasonic Flowmeter. Operating Principle. Features M1500 Plus Noninvasive Inline DSP Ultrasonic Flowmeter Accuracy ± 2% of Reading All wetted parts made of PFA Contamination free from ions or particles Minute flow measurements down to 4 ml/min* Easy configuration

More information

ULTRAFLO 2000 ULTRASONIC LIQUID FLOW AND HEAT/ENERGY METERS FOR PERMANENT INSTALLATION HIGH TEMPERATURE SENSORS AS STANDARD

ULTRAFLO 2000 ULTRASONIC LIQUID FLOW AND HEAT/ENERGY METERS FOR PERMANENT INSTALLATION HIGH TEMPERATURE SENSORS AS STANDARD ULTRASONIC LIQUID FLOW AND HEAT/ENERGY METERS HIGH TEMPERATURE SENSORS AS STANDARD FOR PERMANENT INSTALLATION ULTRASONIC LIQUID FLOW AND HEAT/ENERGY METERS The Ultraflo 2000 is a Transit Time ultrasonic

More information

Related vacuum products

Related vacuum products Vacuum component C O N T E N T S variation 420 Position locking valve () 422 Compact vacuum regulator () 426 Vacuum break unit () 436 Vacuum filter large volume union type (VSFB) 440 Compact vacuum filter

More information

Inline Ultrasonic Flowmeter

Inline Ultrasonic Flowmeter M-1500 Series Installation and Operating Manual The M-1500 series is an inline primary flow sensor and externally mounted controller unit. The flow sensor is a straight through flow tube that uses Transit

More information

UCM -04A/06A RoHS compliance

UCM -04A/06A RoHS compliance Converter integrate type ultrasonic flowmeter -4A/6A RoHS compliance ULTRASONIC COMPACT METER LE The -4A/6A is the converter integrate type ultrasonic flowmeter for small flow that offers precise an stable

More information

SRT1000 Series THERMAL FLOWMETER

SRT1000 Series THERMAL FLOWMETER High-performance gas flowmeter SRT1000 Series THERMAL FLOWMETER OUTLINE Based on the long experienced know-how on the TOKYO KEISO's thermal flowmeters, SRT1000 series has enhanced its performance such

More information

1000 Series MASSMAX. Coriolis Mass Flowmeter Straight Twin Tube OUTLINE FEATURES STANDARD SPECIFICATIONS. Fluid Specifications

1000 Series MASSMAX. Coriolis Mass Flowmeter Straight Twin Tube OUTLINE FEATURES STANDARD SPECIFICATIONS. Fluid Specifications MSSMX Series Coriolis Mass Flowmeter Straight Twin Tube OUTLINE MSSMX series is the coriolis mass flowmeters developed on the theme of the straight tube model which is excellent in cost performance. The

More information

UFM 800 W, C and UFM 800 W Hot Tapping. Ultrasonic flowmeters. for water and wastewater

UFM 800 W, C and UFM 800 W Hot Tapping. Ultrasonic flowmeters. for water and wastewater KROHNE 12/2006 7.02343.22.00 MAR UFM 800 W, C and UFM 800 W Hot Tapping Ultrasonic flowmeter for water and wastewater...with weld-in sensors for metal pipelines...with built-on or built-in sensors for

More information

Range of Ultrasonic Flowmeters.

Range of Ultrasonic Flowmeters. Range of Ultrasonic Flowmeters www.adeptfluidyne.com Ultrasonic Flowmeter Series 6700 Working Principle The Transit Time Flowmeter utilises two transducers that function as both, ultrasonic transmitters

More information

Digital Vortex Flowmeter. digitalyewflo. Digital Vortex Flowmeter. Series

Digital Vortex Flowmeter. digitalyewflo. Digital Vortex Flowmeter. Series Digital Vortex meter digitalyewflo Digital Vortex meter Series Unrivaled Performance, Functionality and Ease of Use Series Standard Type / Multi-variable Type High Temperature / Cryogenic Type Reduced

More information

Appendix. Clearance. Skewed profiles. Application Schematics

Appendix. Clearance. Skewed profiles. Application Schematics Appendix Application Schematics The purpose of the application schematics is to show different applications and the best sensor location for a particular application. Clearance Because the sensor will

More information

Flow Measurement. SITRANS F US Clamp-on. SITRANS FUP1010 (Portable) 4/318 Siemens FI Overview

Flow Measurement. SITRANS F US Clamp-on. SITRANS FUP1010 (Portable) 4/318 Siemens FI Overview Flow Measurement Siemens G 2011 Overview SITRNS FUP1010 clamp-on non-intrusive ultrasonic flow transmitter offers maximum versatility plus battery power for portable field use. It can operate in either

More information

FLOW METER ULTRASONIC-VOLTEX FLOW METER ASUSV SERIES IMPELLER FLOW METER ASIP80 SERIES IMPELLER FLOW METER ASSPX SERIES

FLOW METER ULTRASONIC-VOLTEX FLOW METER ASUSV SERIES IMPELLER FLOW METER ASIP80 SERIES IMPELLER FLOW METER ASSPX SERIES FLOW METER P.193 P.195 P.196 P.197 P.198 P.198 P.198 P.199 P.199 P.200 P.200 P.200 P.200 ULTRASONIC-VOLTEX FLOW METER ASUSV SERIES IMPELLER FLOW METER ASIP80 SERIES IMPELLER FLOW METER ASSPX SERIES INSERTION

More information

Dissolved Oxygen Measurement System with Air Blast Cleaner

Dissolved Oxygen Measurement System with Air Blast Cleaner Product Data Sheet PDS 71-DO-03/04/rev.D August 2004 MODEL DO -03/-04 Dissolved Oxygen Measurement System with Air Blast Cleaner COMPLETE SYSTEM INCLUDES sensor, analyzer, sensor washer head, mounting

More information

CDT1000 series QUICK FLOW. Digital Flowmeter for Air Conditioning Application OUTLINE FEATURES STANDARD SPECIFICATION

CDT1000 series QUICK FLOW. Digital Flowmeter for Air Conditioning Application OUTLINE FEATURES STANDARD SPECIFICATION QUICK FLOW CDT1 series Digital Flowmeter for ir Conditioning pplication OUTLINE CDT1 is a new series of flowmeter which combines a multidigital indicator with a pitot tube. CDT1 detects the differential

More information

3 -color/2-screen display

3 -color/2-screen display -color display -color/-screen display Main screen Sub screen Note ) Main screen Sub screen Note ) ccumulated value New Digital Flow Switch for Water Instantaneous flow rate Set value Note ) Peak/ottom

More information

Low Profile Insertion Vortex

Low Profile Insertion Vortex Low Profile Insertion Vortex Product Features The same insertion meter can measure Steam, Gases or Liquids. Standardize on an insertion bar that can measure line sizes 2 24 Heavy Duty & Maintenance Free

More information

Hot Tap Insertion Vortex

Hot Tap Insertion Vortex Hot Tap Insertion Vortex Product Features The same insertion meter can measure Steam, Gases or Liquids. Standardize on an insertion bar that can measure line sizes 2 48 Heavy Duty & Maintenance Free Design

More information

3 -color/2-screen display

3 -color/2-screen display 3-Color Display Digital Flow Switch for Water Series 3 -color/2-screen display RoHS IP65 Main screen Sub screen Note 3) Main screen Instantaneous flow rate Note ) Sub screen Set value Note 3) Instantaneous

More information

Rosemount 8750WA Magnetic Flowmeter System For Water and Wastewater Industries

Rosemount 8750WA Magnetic Flowmeter System For Water and Wastewater Industries Product Data Sheet January 214 813-1-475, Rev FA Rosemount 875WA Magnetic Flowmeter System For Water and Wastewater Industries THE 875WA MAGNETIC FLOWMETER Rosemount reliability in a customized offering

More information

TRANSIT TIME FLOW METERS

TRANSIT TIME FLOW METERS TRANSIT TIME FLOW METERS TTFM100-F1-NG TTFM100-F2000-NG TTFM100-B-HH-NG TTFM100-F18-NG TTFM200-F3-NG TT100/8812NG RAFALLO PERCALIN CORPORATION Unit 10 MSA Prime Center, Prime St., Madrigal Business Park

More information

Model DFX Doppler ultrasonic flow meter

Model DFX Doppler ultrasonic flow meter Badger Meter Europa GmbH Nürtinger Str. 76 72639 Neuffen (Germany) Tel. +49-7025-9208-0 Fax +49-7025-9208-15 www.badgermeter.de badger@badgermeter.de Model DFX Doppler ultrasonic flow meter Features Badger

More information

How to Order 1 T Z A. r Pressure range. 05 Pressure range 0 to 0.5 MPa 10 Pressure range 0 to 1 MPa 16 Pressure range 0 to 1.6 MPa

How to Order 1 T Z A. r Pressure range. 05 Pressure range 0 to 0.5 MPa 10 Pressure range 0 to 1 MPa 16 Pressure range 0 to 1.6 MPa oolant Valve Series S External pilot solenoid S ir operated S How to Order 0 0 Y 0 0 T Z q w e r t y u i o!0!!!!! q Series S00 S00 S00 w Valve type ormally closed ormally open e Seal material R FKM r Pressure

More information

WaterMAG. Electromagnetic Flowmeter for Water Applications. Model MCB10A OVERVIEW APPLICATIONS FEATURES. No. SS2-MCB

WaterMAG. Electromagnetic Flowmeter for Water Applications. Model MCB10A OVERVIEW APPLICATIONS FEATURES. No. SS2-MCB WaterMAG Electromagnetic Flowmeter for Water Applications OVERVIEW The WaterMAG is an electromagnetic flowmeter for water measurement applications based on field proven Azbil Corporation's technologies.

More information

3-colour / 2-screen display

3-colour / 2-screen display 3-colour display RoHS New Digital Flow Switch for Water IP65 3-colour / 2-screen display Main screen Sub screen Note 3) Main screen Sub screen Note 3) Instantaneous flow rate Set value Note ) ccumulated

More information

PG-30 PRESSURE GAUGES P G R - N MODEL NUMBER DESIGNATION

PG-30 PRESSURE GAUGES P G R - N MODEL NUMBER DESIGNATION INTERNAL STRUCTURE 5 1 marking Compatible with EMC directive 2 6 4 3 Part name Material 1 Pressure sensor P-2000 2 Sensor O ring NBR 3 Adaptor Aluminum Die-casting 4 Case O ring NBR 5 Case PBT (Polybutyleneterephthalate)

More information

Lower maintenance costs: with no moving parts, there is nothing on the DFX to wear down. Wide measuring range: 0.15 to 30 FPS (0.05 to 9 MPS).

Lower maintenance costs: with no moving parts, there is nothing on the DFX to wear down. Wide measuring range: 0.15 to 30 FPS (0.05 to 9 MPS). PRODUCT APPLICATIONS / APPLICATION QUALIFICATION DIMENSIONAL SPECIFICATIONS MECHANICAL DIMENSIONS: INCHES (mm) DOPPLER ULTRASONIC FLOW METER Carbonated liquids Mining slurry Drilling mud Coal-seam water

More information

ISTEC MAGNETIC METERS

ISTEC MAGNETIC METERS ISTEC MAGNETIC METERS MEASURE ANY CONDUCTIVE LIQUIDS OR SLURRIES (EVEN ABRASIVE OR CORROSIVE) WITH THE NEW MICROPROCESSOR-BASED MAGNETIC METER -- A QUALITY PRODUCT - SIMPLE - RELIABLE - AT AN AFFORDABLE

More information

DYNAMETERS SERIES DMTF ULTRASONIC FLOW METER

DYNAMETERS SERIES DMTF ULTRASONIC FLOW METER DYNAMETERS SERIES DMTF ULTRASONIC FLOW METER Advanced Clamp-on Transit-time Ultrasonic Flow meter for Accurate Flow Measurement Features: Cost effective and versatile High accuracy, better than ±1.0% read

More information

General Specifications

General Specifications eneral Specifications Model TB Surface Scattering Light Meter S 12E04A02-01E eneral There have been increasing demands for both industrial use and portable water of good quality because of rapid industrial

More information

Integrated Flow Control Module for Slurries and Chemicals LFC-7000

Integrated Flow Control Module for Slurries and Chemicals LFC-7000 Integrated Flow Control Module for Slurries and Chemicals LFC-7000 Operating Instructions and Quick-Start Guide TABLE OF CONTENTS Introduction 3 Storage and Handling 3 Installation Instructions 4 Operating

More information

An Innovative Flow Sensor

An Innovative Flow Sensor NEW Separate-amplifier type digital flow sensor FD-V7 Series An Innovative Flow Sensor PPS PFA 5 liters 2 liters 5 liters 4 liters 2 liters The debut of an innovative, Ultimate convenience has been separate-amplifier

More information

MASSMAX 1000 Series Straight twin tube Coriolis Mass Flowmeter

MASSMAX 1000 Series Straight twin tube Coriolis Mass Flowmeter MASSMAX Series Straight twin tube Coriolis Mass Flowmeter OUTLINE MASSMAX series is the coriolis mass flowmeters developed on the theme of the straight tube model which is excellent in cost performance.

More information

유량계전문제조업체. Electro Magnetic FLOWMETER

유량계전문제조업체. Electro Magnetic FLOWMETER 유량계전문제조업체 w w w. f c k o r e a i n s. c o m Electro Magnetic FLOWMETER ELECTRO-MAGNETIC FLOW METER Contents Principle of Operation 04 Grounding Method 05~07 Piping Installation 08 CN-400 CNT-2 Flanged

More information

Orifice Flow Meter (Series FKOP/FKOE)

Orifice Flow Meter (Series FKOP/FKOE) Overview FKOP and FKOE series is low-cost flow meter for liquids and gases based on orifice principle. FKOP series combines a variable area flow meter (rotameter) and orifice flow meter principles. A small

More information

PG-30 PRESSURE GAUGES P G R - N FEATURES MODEL NUMBER DESIGNATION

PG-30 PRESSURE GAUGES P G R - N FEATURES MODEL NUMBER DESIGNATION marking Compatible with EMC directive INTERNAL STRUCTURE 5 1 2 6 4 3 Part name Material FEATURES 1 Pressure sensor P-2000 Compact and lightweight general-purpose pressure gauges Innovative general-purpose

More information

Full Profile Insertion

Full Profile Insertion FPI Mag Meter Full Profile Insertion High Performance Electromagnetic Flow Meter Municipal Market Product Presentation Manufactured exclusively by McCrometer, Inc. Hemet, CA USA 55+ Years of Experience

More information

ProSeries NEMA 4X SONIC-PRO. Engineering and Technical Data. Transit Time Ultrasonic Flowmeter. Industries, Ltd. s Ultrasonic Flow Meters

ProSeries NEMA 4X SONIC-PRO. Engineering and Technical Data. Transit Time Ultrasonic Flowmeter. Industries, Ltd. s Ultrasonic Flow Meters ProSeries by Blue-White Industries, Ind. Ltd. Industries, Ltd. s SNIC-PR s SNIC-PR s S4 Transit Time Ultrasonic Flowmeter ½ thru 2 diameter Pipe Sizes Inline spool piece Advanced communications Data logging

More information

JUMO ecotrans Lf 01/02

JUMO ecotrans Lf 01/02 Data Sheet 07 Page /7 JUMO ecotrans Lf 0/0 Microprocessor Transmitter/Switching Device for Conductivity Housing for DIN rail mounting (5 mm 7.5 mm to EN 075 A.) Brief description The JUMO ecotrans Lf 0/0

More information

Model FVP General Specification. Flanged Vortex Plate. Product Features

Model FVP General Specification. Flanged Vortex Plate. Product Features Flanged Vortex Plate Product Features Our Inline meters can measure Steam, Gases or Liquids. Measures two times lower than any other Vortex Meter. Heavy Duty & Maintenance Free Design C&C Machined from

More information

O-1000 Series ORIFLOMETER MOST COST EFFECTIVE FLOW MEASUREMENT GENERAL STANDARD SPECIFICATIONS TYPES AND FUNCITON

O-1000 Series ORIFLOMETER MOST COST EFFECTIVE FLOW MEASUREMENT GENERAL STANDARD SPECIFICATIONS TYPES AND FUNCITON MOST COST EFFECTIVE FLOW MEASUREMENT O-1000 Series ORIFLOMETER GENERAL O-1000 series ORIFLO METER is a flow meter consisting of an orifice plate and a metal tube variable area flow meter. Since the flow

More information

220 Series Innova-Flo o

220 Series Innova-Flo o Smart Vortex Flow Meter Features Volumetric flow monitoring of most gases, liquids and steam Smart electronics extends range down to a Reynolds number of 5000 Insertion style allows installation in any

More information

MagneW 3000 PLUS Smart Electromagnetic Flowmeter

MagneW 3000 PLUS Smart Electromagnetic Flowmeter MagneW 3000 PLUS Smart Electromagnetic Flowmeter Model MG14(onverter with FOUNDTION Fieldbus) / MG18 (Detector)ENRI Flowmeter for Pulp Slurry OVERVIEW The MagneW 3000 PLUS ENRI (igh-energy Noise-Resistant

More information

OPTIONS BLANK = No Options B = BACnet MS/TP D = Internal Transmitter Display (Ref Note 4)

OPTIONS BLANK = No Options B = BACnet MS/TP D = Internal Transmitter Display (Ref Note 4) MOEL COE UCT SHAPE = Round = Rectangular = Flat Oval PROBE MATERIAL = Aluminum/ABS = CPVC & ABS = 0SS = High Temp SS (50 F / C Max) PROBE QUANTITY = = s = s = s SENSORS PER PROBE = Sensor per = Sensors

More information

MEASURE TODAY. ENSURE TOMORROW. SpireMag Series T-MAG Electromagnetic BTU Meter

MEASURE TODAY. ENSURE TOMORROW. SpireMag Series T-MAG Electromagnetic BTU Meter MEASURE TODAY. ENSURE TOMORROW. SpireMag Series T-MAG Features The T-MAG BTU meter is the latest addition to the SpireMag series for accurate thermal energy measurement. It utilizes a high accuracy electromagnetic

More information

ULTRASONIC FLOWMETER / HEATMETER

ULTRASONIC FLOWMETER / HEATMETER TUF-000F SERIES ULTRASONIC FLOWMETER / HEATMETER www.tuf-000. TUF-000F www. tuf- 000. CONTENTS OVER 0 YEARS' EXPERIENCES SPECIALIZED IN ULTRASONIC FLOW METERS PROFILE 1 Fixed Mounted Inline Type Ultrasonic

More information

The readings you need, right where you need them. AX Series Vortex Meters

The readings you need, right where you need them. AX Series Vortex Meters The readings you need, right where you need them. AX Series Vortex Meters Multivariable function from a single meter Vortex multivariable meters from Azbil North America employ three sensing elements in

More information

Compact / Lightweight 2 Port Solenoid Valve

Compact / Lightweight 2 Port Solenoid Valve ompact / Lightweight 2 Port Solenoid Valve /-XF For ir/water ompact / Lightweight resin body (PPS) Weight: 20 g (-XF) RoHS IP65 mm Power consumption 3 W (Standard) 0.5 W (With power-saving circuit) 48

More information

Stepping Motor and Driver Package. High-Efficiency AR Series. DC Power-Supply Input. Built-in Controller Type Pulse Input Type

Stepping Motor and Driver Package. High-Efficiency AR Series. DC Power-Supply Input. Built-in Controller Type Pulse Input Type Stepping Motor Driver Package High-Efficiency R Series DC Power-Supply Input Built-in Type Type The extensive R Series DC Power-Supply Input lineup that utilizes high-efficiency technology. Two types are

More information

To avoid injury, death of personnel ordamage to instrument, the operator must refer to an explanation in the User smanual.

To avoid injury, death of personnel ordamage to instrument, the operator must refer to an explanation in the User smanual. www.malema.com VF-3000 Flow Sensor M-1500 INSTRUCTION MANUAL Non-invasive Inline 1. NOTICE 1) This manual should be passed on to the installer and the operator of this product. 2) Please read this manual

More information

Q1 Q2 Q3. 2 stage performance. 3 stage performance. Suction flow rate. 250% suction flow rate increase. Release flow rate adjusting needle.

Q1 Q2 Q3. 2 stage performance. 3 stage performance. Suction flow rate. 250% suction flow rate increase. Release flow rate adjusting needle. Multistage Ejector 112/212 Series Energy-saving, large flow rate, 3 stage diffuser construction Suction flow rate increased 25% and air consumption reduced 2% with 3 stage diffuser construction (ersus

More information

Accurate measurement of compressed air consumption and detection of leaks. Measuring the individual consumption per customer / cost centre

Accurate measurement of compressed air consumption and detection of leaks. Measuring the individual consumption per customer / cost centre Inline Flowmeter for compressed air and gases DN15 - DN50 / 16 bar The flow meter of the series, based on the measurement principle of thermal mass flow, is ideally suited for the measurement of flow of

More information

Detector (for water measurement applications)

Detector (for water measurement applications) WaterMAG Smart Electromagnetic Flowmeter Detector (for water measurement applications) Model MGW18 OVERVIEW The WaterMAG electromagnetic flowmeter detector is a high performance, highly reliable flowmeter

More information