1000 Series MASSMAX. Coriolis Mass Flowmeter Straight Twin Tube OUTLINE FEATURES STANDARD SPECIFICATIONS. Fluid Specifications
|
|
- Brittany Crawford
- 6 years ago
- Views:
Transcription
1 MSSMX Series Coriolis Mass Flowmeter Straight Twin Tube OUTLINE MSSMX series is the coriolis mass flowmeters developed on the theme of the straight tube model which is excellent in cost performance. The straight measuring tube, designed on the basis of integrated know-how of the field experiences and customer s requirements, allows self-cleaning of the tube and low pressure loss with the high allowable pressure of the outer cylinder. The meter enjoys high-quality, safety and good cost performance. The wetted parts are made of stainless steel and the outer cylinder of the measuring tube has the pressure proof of 6.3MPa. Four sizes from 5 to 5mm in diameter are available. MSSMX series can be applied to wide application from small flow to large flow. FETURES Self-cleaning, low pressure loss and low cost application igh accuracy: ±.% of reading (+ Zero stability) Safe design of stainless steel cylinder with dual structure (Maximum working pressure: 6.3MPa) pplicable to chemical and petrochemical services which require safety. pplicable to the food and pharmaceutical industries with the sanitary ferrule connection (3 approved) One meter can measure the mass flow rate (both instantaneous and totalized), density and temperature at the same time. The converter, either integrated mounted with detector or separately mounted, is available. TEX explosion proof and TIIS* explosion proof types are provided. STNDRD SPECIFICTIONS Measurement principle : Coriolis force : 5, 5, 4, 5mm Measuring range Max. nominal flow rate Min. flow rate kg/h 4,8 48, 6, 6 5, 5 Max. nominal flow rate Min. flow rate kg/min ,,83.83 Dust and waterproof : IP66/67 (IEC 659) mbient temperature : 4 to +55 C (Integrated mounted version) 4 to +6 C (Separately mounted detector and converter itself) * Refer to the SPECIFICTIONS OF EXPLOSION PROOF TYPE for the ambient temperature range of explosion proof type. Fluid Specifications Measuring fluid : Liquids Fluid temperature Connection type Flange type Sanitary ferrule Fluid pressure 5 Temperature 4 to +3 C to +3 C Pressure Fluid temp. C MPa 5 MPa 4 MPa 5 MPa * Pressure means the maximum working pressure of the sensor tube. * Refer to the FLUID PRESSURE-TEMPERTURE TBLE shown on the another page of this guidance for details. * Maximum working pressure must be within the limits of the flange or fitting rating. Fluid density : 4 to 5kg/m 3
2 MSSMX Series Straight Twin Tube / Coriolis Mass Flowmeter Sensor Specifications Process connection Flange ; JISK/K R.F., SME class 5/3 R.F., Others Sanitary fittings ; ISO85 Ferrule, Others (Option) Material Wetted parts : Wetted parts Sensor tube Flow splitter Flange Material Stainless steel (UNS S383) * Equivalent to JIS SUS39J3L Stainless steel (SS36L) Stainless steel (SS36L) Non-wetted parts : Outer cylinder ; Stainless steel (SS34L) Converter mount and Front end housing ; Stainless steel (SS36L) Outer cylinder : 6.3MPa at C (Standard) pressure rating MPa at C (Option) Converter Specifications Cylinder material Painting : luminum alloy (Option: SS36L) : Siloxane coating Color : Grey (Converter housing), Jade green (Converter cover / Terminal box cover) Power supply : to 3V C (85 to 53V) Option; 4V DC (9 to 3V) ( ) indicates voltage range Power supply : 48 to 63 z frequency Power consumption : C ; approx. 8V, DC ; approx. W Grounding : Grounding resistance must be less than Ω for Non-Ex. version Ω for Ex. version Cable Entry : G/ female adapters or / NPT female adapters or G/ Flame proof adapters cable glands (applied for TIIS explosion proof ) * Maximum 3 cable entries are available. Indication and Output Specifications Indicator : Blue, dot matrix LCD (With backlight) 8 64 pixels (59 3mm) Indication function : Changeable from maximum 4 screens The Indication data are displayed in one to three lines on one screen. Contents of indication ; Instantaneous mass flow rate(bar graph display), Totalized mass flow rate, Instantaneous volume flow rate, Totalized volume flow rate, Density, Temperature, Flow rate trend graph (percent representation), Setting data and Self-diagnostic indication, etc. Instantaneous mass flow rate : Unit (kg/h, kg/min, kg/sec, t/h, Others) Flow direction normal or reverse, is displayed by + or. Totalized mass flow rate : Unit (kg, t, g, Others) Totalized flow of normal or reverse direction Density display : Unit (g/cm 3, kg/m 3, Others) Temperature display : Unit ( C, Others) Current output : 4 to m DC (Max. m) When power is supplied internally : Load resistance (Less than ohms) When power is supplied externally : External voltage (Less than 3V DC) Pulse output : Open collector output Load rating : 3V DC, m or less ( kz) m or less ( kz) Output frequency : Max. kz Pulse rate : to 36,, pulse/h (.56z to kz) Pulse width : One of the following selectable ) utomatic ; Pulse width by which duty factor to be 5% at full scale ) Duty factor ; : fixed 3) Free setting ;.5 to m/s : Open collector output Load rating : 3V DC, m or less m or less ( kz) Contents of output : One of the following selectable: ) No status output (Standard factory setting) ) Identification of flow direction 3) Over range 4) Totalization preset 5) Identification of range (For double range measurement) 6) Error / Other various measurement alarms (Flow rate, Density, Temperature, etc.) TOKYO KEISO CO., LTD. TG-EM65E-8
3 MSSMX Series Straight Twin Tube / Coriolis Mass Flowmeter Control input Voltage input : Low ; to.5v DC igh ; 9 to 3V DC Contents : ) No control input (Standard factory setting) ) old output signal 3) Lock output signal to % 4) Reset totalized counter 5) Reset error 6) Select range (For double range measurement) 7) Others Output combination Standard output : Current output 4 to m Pulse output Control input Total - 4 points Option : Current output 4 to m Pulse output Total - 3 points Option : Current output 4 to m 3 Pulse output Total - 4 points Option 3 : Current output 4 to m Pulse output or Pulse output (Selectable at site) Total - 4 points * Refer to Output of converter specification code. Low flow cutoff : Current output, Pulse output, Separate setting per each indication is possible Setting value :. to.% FS Standard setting value: Current output, Pulse output ; ON %, OFF 3% FS Damping time constant : Current output, Pulse output, Separate setting per each indication is possible Setting value :. to. s Standard setting value: Current output, Indicator ; 3 s Pulse output ; s Standard Specifications rbitrary flow measuring units can be set freely as a standard function : The measuring units of mass flow rate, volume flow rate and time can be built up using the maximum 7 letters. Bi-directional flow measurement function : Regular or reverse flow is measurable flow-direction distinction signal is given in status output. Self diagnosis function : The following status of errors and operating conditions are indicated as error message ; Functional diagnosis : CPU, Memory, Software, ard, and Output connection Status diagnosis : Over range, Counter over, and Power fail detection pplication diagnosis : Oscillating balance of sensor tube, Vibrating energy, and Diagnosis of sensor circuit. Memory save function at power failure : Operation parameters and totalized figures are stored for more than years by EEPROM (Non volatile memory). Testing function : Simulating output function for current and pulse is available. Loop check can be made without calibrator. Touch sensor setting function (Infrared radiation) : By four infrared sensors, data setup from exterior is possible without removing cover. TG-EM65E-8 TOKYO KEISO CO., LTD. 3
4 MSSMX Series Straight Twin Tube / Coriolis Mass Flowmeter ccuracy (Calibrated at the factory) Mass flow (Pulse output) ccuracy Zero stability ±.% of reading ±.5% of nominal flow rate * Reference conditions : Fluid; Water, Temp. C, Press..MPa [Measurement error] (ccuracy + Zero stability) Measuring error (±% of reading) % of max. nominal flow rate % 5% % % 5% % Flow rate (% of max. nominal flow rate) Measuring error ( ± of reading) * % or less of the max. nominal flow rate (less than minimal flow rate) is out of prescribed accuracy range. Influence by process condition : Temperature effect ; ±.75% of the maximum nominal flow rate per C Pressure effect ; ±.5% of the maximum nominal flow rate per.mpa The influence of the above shows the case where a process condition changes after zero point adjustment. Density (Indicated value) pplicable meter size 5, 5, 4, 5 Measuring range ccuracy calibrated at the factory * ( 5, 4, 5) ccuracy calibrated at the factory * ( 5) 4 to 5 kg/m 3 kg/m 3 5 kg/m 3 * Calibration at the factory is conducted as customers requests. EXPLOSION PROOF TYPE TIIS (Technology Institute of Industrial Safety in Japan) () Compact type (Integrated type sensor and converter) Model : MMM3C-JEx Type of protection and class : Ex d [ib] llc T3 Sensor : Ex ib llc T3 Converter : Ex d [ib] llc T3 Certified No. : No. TC84 No. TC84 mbient temperature : to +5 C Fluid temperature : to +3 C (T4) TEX [EU TEX directive (94/9/EC)] Compact type Temperature class T4 T3... T T4... T Separate sensor Temperature class T4 T3... T Separate converter Temperature class T4... T Max. fluid temperature mbient temperature 7 C 3 C +5 C 55 C +55 C Max. fluid temperature mbient temperature 89 C 3 C +65 C mbient temperature 4 to +65 C Fluid Pressure Temperature Table Pressure (MPa) Sensor tube and Outer cylinder (Option) DIN636 PN63 Outer cylinder (Standard) DIN636 PN4 JISK JISK Temperature ( C) Temperature (Indicated value) Measuring range ccuracy 4 to +3 C ± C 4 TOKYO KEISO CO., LTD. TG-EM65E-8
5 MSSMX Series Straight Twin Tube / Coriolis Mass Flowmeter NME OF EC PRT PROCESS CONNECTION [Integrated type] Flange connection Cable entry Sensor Standard Semi-standard Option Equiv. to JIS * Equiv. to SME Equiv. to JIS / SME * Power supply Front end 5 5 K /" class5 5 K " class5,3,6 Input / Output ESC Converter 5 5 K " class5 4 K -/" class5,3,6 4 4 K -/" class5 5 K " class5,3,6 5 5 K " class5 8 K 3" class5,3,6 * JISK flange is commonly used for JIS K to K 4 flange as standard. (Installation dimensions of JISK flange are equal to JISK except the flange thickness.) Outer cylinder FLOW RNGE Max. nominal flow rate kg/h kg/min 4,8 8, 333 6,, 5,,83 Flange llowable max. flow rate kg/h kg/min 6,4 4 6, 433 7,,3 6,5,78 Sanitary fitting (Option) 5 Fitting " ISO 85 Ferrule (equivalent to IDF ferrule) 5 -/" ISO 85 Ferrule (equivalent to IDF ferrule) 4 " ISO 85 Ferrule (equivalent to IDF ferrule) 5 3" ISO 85 Ferrule (equivalent to IDF ferrule) SENSOR TUBE DIMENSIONS Material Sensor tube dimensions (mm) Inside diameter Wall thickness 5 S S S S The sensor tube is consisted of a straight twin tubes (two measurement pipes) as shown in the following figure. TG-EM65E-8 TOKYO KEISO CO., LTD. 5
6 MSSMX Series Straight Twin Tube / Coriolis Mass Flowmeter ELECTRICL CONNECTION [Converter Input/Output Terminals] MMC3C/F Current output, Pulse output,, Control input, as standard + B B C C D D N L (L) (L+) Output wire connection figure of optional case Module I/O PCB Converter specification Terminal Polarity Option Option Option 3 Current outputs 3 Current outputs Current outputs Pulse or (68) Pulse or (6) Pulse or (6E) D D + Pulse or Pulse or Pulse or C Current output No. Current output No. Current output No. (Internal power (Internal power (Internal power C + supply) supply) supply) B Current output No. Pulse or (Internal power B + supply) + Current output No. Current output No.3 Current output No. (Internal power (Internal power (Internal power + supply) supply) supply) [Separate Type Sensor Cable] MMSF + MMC3F The protection cover is provided for power supply terminals. Power supply terminal cover Converter MMC3F side B + Terminal connector Shield earth Grip for cable fixing (for Earth) Cable gland Terminal Description L / L+ N / L Terminal L+ (+) L () (C power supply / DC power supply) Grounding Description (standard) Polarity Sensor cable (Exclusive use) 4-cores compound cable :.5mm Finished outer diameter : pprox. mm Maximum Length : 3m D D Pulse output or + C C + B B or Control input + Cable gland Current output + (4 to m DC / Internal + power supply) Current output (4 to m DC / Internal power supply) Current output (4 to m DC / External power supply) + Grip for cable fixing Terminal block B + Detector MMSF side Spring clamp terminal.5 to.5mm applicable cable : 7 to mm Terminal type : Plug-in type screw terminal pplicable electric wire :.5 to.5mm Outer diameter of applicable cable : 7 to mm 6 TOKYO KEISO CO., LTD. TG-EM65E-8
7 MSSMX Series Straight Twin Tube / Coriolis Mass Flowmeter DIMENSIONS Integrated Type (MMM3C) with Flange Connections (G) ϕd 98.5 L Dimensions (mm) L 3 D Weigh (pprox. kg) Dimension L is the length for the flanges of standard specifications.. Dimension and indicate dimensions from the bottom of the outer cylinder. 3. Dimension G Separate Type Converter (MMC3F) (G) ESC 4 inch pipe (Supplied by customers) 6 4 Grounding terminal (M5) 4 (6) R U bolt for inch pipe mount (Supplied by the option) Weight of the converter : pprox. 5.8kg Dimension G TG-EM65E-8 TOKYO KEISO CO., LTD. 7
8 MSSMX Series Straight Twin Tube / Coriolis Mass Flowmeter Separate Type Detector (MMSF) with Flange Connections (6) ϕd L Dimensions (mm) L 3 D Dimension L is the length for the flanges of standard.. Dimension and indicate dimensions from the bottom of the outer cylinder. Weigh (pprox. kg) 8 TOKYO KEISO CO., LTD. TG-EM65E-8
9 MSSMX Series Straight Twin Tube / Coriolis Mass Flowmeter DIMENSIONS Integrated Type (MMM3C) with Sanitary Fittings (G) ϕd L Dimensions (mm) L D Weigh Dimension G Separate Type Detector (MMSF) Sanitary Fittings (6) ϕd L Dimensions (mm) Weigh L 3 D (pprox. kg) TG-EM65E-8 TOKYO KEISO CO., LTD. 9
10 MSSMX Series Straight Twin Tube / Coriolis Mass Flowmeter MODEL ND SPECIFICTION CODE Sensor Tube Material: S (Stainless steel UNS S383) [Standard] Model : Integrated type Separate type detector ; MMSF-S ; MMM3C-S Integrated EX. type ; MMM3C-EEx/JEx-S Separate EX. type detector ; MMSF-EEx/JEx-S Separate type converter ; MMC3F Separate EX. type converter ; MMC3F-EEx/JEx * : code (5... 5) EEx : TEX explosion proof type JEx : TIIS explosion proof type [Detector specification code] Detector spec. code TK Detector code TK (Fixed code) Sensor tube material Sensor tube internal surface finish Process connection (Fixed code) Outer cylinder material eating jacket Type of explosion proof Sanitary approvals Type Calibration Degrease treatment Special feature 4 S Description MMS detector (Twin tube type) always 4 S Stainless steel UNS S383 Standard Polished internal Ra =.8m U 5 JISK Flange V 5 JISK Flange W 4 JISK Flange XG 5 JISK Flange YG 8 JISK Flange KD /" SME class 5 Flange KE /" SME class 3 Flange KF /" SME class 6 Flange LD 3/4" SME class 5 Flange LE 3/4" SME class 3 Flange LF 3/4" SME class 6 Flange MD " SME class 5 Flange ME " SME class 3 Flange MF " SME class 6 Flange ND -/" SME class 5 Flange NE -/" SME class 3 Flange NF -/" SME class 6 Flange PD " SME class 5 Flange PE " SME class 3 Flange PF " SME class 6 Flange RD 3" SME class 5 Flange RE 3" SME class 3 Flange RF 3" SME class 6 Flange MT " ISO85 Ferrule (IDF) NT -/" ISO85 Ferrule (IDF) PT " ISO85 Ferrule (IDF) RT 3" ISO85 Ferrule (IDF) G B Std. : Standard : Semi-standard : Option always Stainless steel 34L Stainless steel 36L Stainless steel 34L llowable pressure: 6.3MPa at C approved by PED Stainless steel 36L llowable pressure: 6.3MPa at C approved by PED Stainless steel 36L llowable pressure: MPa at C approved by PED Nil eating jacket ir purge connection (/ NPT Female) Nil TEX explosionproof TIIS explosionproof Nil EEDG (European ygienic Equipment Design Group) 3 (merican Dairy pproval) SME Bioprocessing Equipment Standard Version Integrated type Separate type (luminum terminal box) Separate type (Stainless terminal box) Calibration Standard (3 points flow calibration) 5 points flow calibration 3 points flow calibration + Density calibration B 5 points flow calibration + Density calibration Nil Degrease treatment for wetted parts (Blank) Nil /Z Involved TOKYO KEISO CO., LTD. TG-EM65E-8
11 MSSMX Series Straight Twin Tube / Coriolis Mass Flowmeter [Converter specification code] MMC3C/F Converter spec. code TK 5 4 Converter code TK 5 MMC3 converter (Fixed code) 4 always 4 Version 4 Power supply Explosionproof pproval Language for indication (fixed code) Converter housing Output and input Sensor cables 9 Cable entries for input and output, and power supply (fixed code) Measuring valuables (fixed code) Special requirements *: In case that special feature are involved, put [/Z] at the end of specification code and specify the details. It is recommended to consult TOKYO KEISO for such availability before ordering. Description Version Integrated type Separate type to 3 V C (85 to 53 V) 4 V DC (9 to 3 V) Nil TEX explosionproof TIIS explosionproof With / NPT female adapter for TEX explosionproof With G/ female adapter M.5 female With G/ flameproof packing adapter for TIIS explosionproof English always luminum alloy Stainless steel SS36L (for integrated type) Stainless steel SS36L (for separate type) always 4 to m, Pulse,, control input to m, Pulse to m, Pulse 6 E 4 to m, Pulse, or Pulse (lternative) Standard (Mass flow rate, Density, Temperature) always Nil (Integrated type or supplied by customer) With m cable (For separate type) With 5m cable (For separate type) 3 With 5m cable (For separate type) (Blank) Nil / Z Involved Std. STNDRD CCESSORIES Instruction manual : * Specification is subject to change without notice. ead Office : Shiba Toho Building, 7 4 Shibakoen, Minato-ku, Tokyo Tel : (KEY) ; Fax : overseas.sales@tokyokeiso.co.jp ; URL : TG-EM65E-8 TOKYO KEISO CO., LTD.
MASSMAX 1000 Series Straight twin tube Coriolis Mass Flowmeter
MASSMAX Series Straight twin tube Coriolis Mass Flowmeter OUTLINE MASSMAX series is the coriolis mass flowmeters developed on the theme of the straight tube model which is excellent in cost performance.
More informationEGM5300C MAGMAX. Compact Electromagnetic Flowmeter GENERAL FEATURES STANDARD SPECIFICATION. General Specification
MAGMAX EGM53C Compact Electromagnetic Flowmeter GENERAL MAGMAX EGM53C is a combination of EGS5 primary head with Ceramic measuring tube and high performance converter EGC3. EGM53C with high durability
More informationEGM1100C MAGMAX. Compact Electromagnetic Flowmeter GENERAL FEATURES STANDARD SPECIFICATION. General Specification
EGMC Compact Electromagnetic Flowmeter GENERA MAGMAX EGMC is the compact type electromagnetic flowmeter with a converter EGC mounted integrally on a primary head EGS lined with fluorocarbon resin PFA.
More informationUL6300 SONICMAX. Ultrasonic Clamp-on Flowmeter OUTLINE FEATURES STANDARD SPECIFICATION. Common specification
SONICMAX UL63 Ultrasonic Clamp-on Flowmeter OUTLINE SONICMAX UL63 is the ultrasonic flowmeter of the time flight system which combined the highly efficient converter (UFC3) with the clamp-on sensor (UFS6).
More informationUL6300 SONICMAX. Ultrasonic Clamp-on Flowmeter OUTLINE FEATURES MEASURING PRINCIPLE
SONICMAX UL63 Ultrasonic Clamp-on Flowmeter OUTLINE SONICMAX UL63 is the ultrasonic flowmeter of the time flight system which combined the highly efficient converter (UFC3) with the clamp-on sensor (UFS6).
More informationVFM4070C SWIRLMAX. Vortex Flowmeter OUTLINE FEATURES OPERATING PRINCIPLE STANDARED SPECIFICATION. General Specification. Sensor Specification
SWIRMAX VFM4070C Vortex Flowmeter OUTINE SWIRMAX is 2-wire, all-in-one type vortex flowmeter with both temperature and pressure sensors integrally mounted into the housing. It allows temperature and pressure
More informationO-1000 Series ORIFLOMETER MOST COST EFFECTIVE FLOW MEASUREMENT GENERAL STANDARD SPECIFICATIONS TYPES AND FUNCITON
MOST COST EFFECTIVE FLOW MEASUREMENT O-1000 Series ORIFLOMETER GENERAL O-1000 series ORIFLO METER is a flow meter consisting of an orifice plate and a metal tube variable area flow meter. Since the flow
More informationSTK2000/7400 Series. Flapper-type Flowmeter OUTLINE FEATURES PRINCIPLE STANDARD SPECIFICATIONS. Specifications of the metal measuring tube
STK2000/7400 Series Flapper-type Flowmeter OUTLINE The STK2000 and STK7400 are high-accuracy, high-performance, flapper-type flowmeters. The STK2000 is a local indication type, and the STK7400 is a local
More informationAM-2000 series HYBRID FLOWMETER
AM- series HYBRID FLOWMETER OUTLINE AM- series is a new all metal type flowmeter. AM- series integrates formerly separate functional devices to facilitate mounting in restricted spaces. Suitable for liquid,
More informationUL350 ULTRASONIC FLOWMETER CLAMP-ON TYPE OUTLINE FEATURES MEASUREMENT PRINCIPLE
CLMP-ON TYPE UL350 ULTRSONIC FLOWMETER OUTLINE Our clamp-on type Ultrasonic Flowmeter UL350 has enabled applications to piping in various kinds by enhancing the permeation property of ultrasonic wave.
More informationR-101-E GLASS TUBE FLOWMETER BEST COST PERFORMANCE GENERAL STANDARD SPECIFICTION. Max. fluid press. MPa Meter size.
BEST COST PERFORMANCE R-1-E GLASS TUBE FLOWMETER GENERAL R-1-E is a glass tube type variable area flowmeter. The flow rate is indicated by the position of float and the graduation engraved on the glass
More informationSRT1000 Series THERMAL FLOWMETER
High-performance gas flowmeter SRT1000 Series THERMAL FLOWMETER OUTLINE Based on the long experienced know-how on the TOKYO KEISO's thermal flowmeters, SRT1000 series has enhanced its performance such
More informationAM9000 Series GENERAL FEATURES METAL TUBE VARIABLE AREA FLOWMETER
METAL TUBE VARIABLE AREA FLOWMETER AM9000 Series GENERAL The AM9000 series metal tube variable area flowmeters have the unified face-to-face dimension mm. Having developed the current well-accepted AM7000
More informationCDT1000 series QUICK FLOW. Digital Flowmeter for Air Conditioning Application OUTLINE FEATURES STANDARD SPECIFICATION
QUICK FLOW CDT1 series Digital Flowmeter for ir Conditioning pplication OUTLINE CDT1 is a new series of flowmeter which combines a multidigital indicator with a pitot tube. CDT1 detects the differential
More informationOPTIMASS 3000 Technical Datasheet
OPTIMASS 3000 Technical Datasheet Sensor for mass flow First choice for low flow applications Certified secondary pressure containment A common footprint for all three sizes, in Hastelloy or Stainless
More informationMicro Motion T-Series Straight-Tube Mass Flow and Density Meters. Product Data Sheet PS July 2001
Micro Motion T-Series Straight-Tube Mass Flow and Density Meters Product Data Sheet PS-00371 July 2001 Micro Motion T-Series Straight-Tube Meters Micro Motion is proud to offer you the first single-straight-tube
More information7000 Series OPTIMASS Mass Flowmeters. Titanium Hastelloy Stainless Steel
KROHNE 04/2004 7.02445.24.00 GR 7000 Series OPTIMASS Mass Flowmeters with single straight measuring tube Titanium Hastelloy Stainless Steel Status: 10/99 Status: 10/99 One tube no limits No limits with
More informationOPTIMASS 2000 Technical Datasheet
OPTIMASS 2000 Technical Datasheet Sensor for bulk mass flow Large diameter for bulk measurement and custody transfer of liquids and gases Stainless Steel measuring tubes (NACE Compliant) Modular electronics
More informationSITRANS F flowmeters SITRANS F C
SITRNS F flowmeters Siemens G 2008 Overview is available as a standard version (DN 50 to DN 150 (2 to 6 )) and a hygienic, EHEDG certified version (DN 20 to DN 80 (¾ to 3 )). MC2 and MC2 hygienic are suitable
More informationLCMass Series Mass Flow Sensor
LCMass 100-140 Series Mass Flow Sensor Technical Data Sheet HIGH ACCURACY The LCMass 100 achieves a ±0.15% accuracy on liquids. COMPACT ECONOMIC DESIGN Straight twin-tube design allows for an overall smaller
More informationSITRANS F C. Flow sensor MC2 4/193. Overview
Siemens G 2011 low Measurement SITNS C Overview The main applications of the Coriolis flowmeter can be found in all industries, such as: Chemical and pharma Detergents, bulk chemicals, pharmaceuticals,
More informationMetal tube flowmeters. Series SC250. Metal Tube Flow Meters. Series SC250. Variable area flowmeter for liquids, gases and steam
Metal tube flowmeters Variable area flowmeter for liquids, gases and steam Metallic or plastic tube with a robust construction Indication by means of magnetic coupling Scales calibrated in l/h, m 3 /h,
More informationSITRANS F flowmeters SITRANS F C SITRANS F C MC2 4/169. Overview
Siemens G 2009 SITRNS flowmeters SITRNS C SITRNS C MC2 Overview SITRNS C MC2 is available as a standard version (DN 50 to DN 150 (2 to 6 )) and a hygienic, EHEDG-certified version (DN 20 to DN (¾ to 3
More informationO-100 Series GLASS TUBE TYPE ORIFLOMETER BEST COST EFFECTIVE FLOW MEASUREMENT EVEN FOR LARGE SIZE LINES GENERAL STANDARD SPECIFICATION MODEL CODE
BEST COST EFFECTIVE FLOW MESUREMENT EVEN FOR LRGE SIZE LINES O-0 Series GLSS TUBE TYPE ORIFLOMETER GENERL O-0 series ORIFLO METER is a flow meter consisting of a orifice plate and a GLSS TUBE type variable
More informationFood & beverage. Oil & gas. Water & waste water
Overview MSS 2100 MC1 DN 50 to DN 150 (2 to 6 ) are suitable for accurate mass flow measurement for all kind of liquids and gases. The sensor offers superior performance in terms of flow accuracy, turn-down
More informationSITRANS F flowmeters SITRANS F C MASSFLO MASS MC1. 4/146 Siemens FI Overview
Overview MSS 2100 MC1 DN 50 to DN 150 (2 to 6 ) is suitable for accurate mass flow measurement for all kind of liquids and gases. The sensor offers superior performance in terms of flow accuracy, turn-down
More informationMetal tube variable area flowmeter for gases, liquids and steam
Metal tube variable area flowmeter for gases, liquids and steam Metallic or plastic tube with a robust construction Indication by means of magnetic coupling Scales calibrated in l/h, m 3 /h, kg/h, t/h,
More informationSITRANS FX300 4/289. System Overview. Overview
Siemens G 2008 SITRNS F flowmeters Overview System Overview Version Single transmitter Dual transmitter Options Standard Pressure sensor Flange Pressure sensor and isola- Standard tion valve Sandwich vortex
More informationVersaFlow Coriolis 100 Mass Flow Sensor Specifications
VersaFlow Coriolis 100 Mass Flow Sensor Specifications 34-VF-03-09 May 2011 The Universal Solution for the Process Industry VERSAFLOW is the only sensor for mass flow in its class with secondary pressure
More informationMicro Motion F-Series Coriolis Flow and Density Meters
Product Data Sheet PS-00603, Rev. F December 2007 Micro Motion F-Series Coriolis Flow and Density Meters Micro Motion F-Series Coriolis meters offer highly accurate mass flow, volume flow, and density
More informationRHM40. Coriolis Mass Flow Meter for Demanding Applications. Features. Applications. Benefits
RHM40 Coriolis Mass Flow Meter for Demanding Applications Features Standard pressure ratings up to 433 bar (6280 psi) Temperature ratings from -196 to 350 C (-320 to 662 F) Mass flow uncertainty down to
More informationRHM30. Coriolis Mass Flow Meter for Plant and Loading Flows. Features. Applications. Benefits
RHM30 Coriolis Mass Flow Meter for Plant and Loading Flows Features Standard pressure ratings up to 798 bar (11574 psi) Temperature ratings from -196 to 350 C (-320 to 662 F) Mass flow uncertainty down
More information유량계전문제조업체. Electro Magnetic FLOWMETER
유량계전문제조업체 w w w. f c k o r e a i n s. c o m Electro Magnetic FLOWMETER ELECTRO-MAGNETIC FLOW METER Contents Principle of Operation 04 Grounding Method 05~07 Piping Installation 08 CN-400 CNT-2 Flanged
More informationRHM 12 - Standard 1 inch Coriolis Mass Flowmeter
RHM 12 - Standard 1 inch Coriolis Mass Flowmeter The RHM 12 can measure flow rates up to 100 kg/min with temperatures in excess of 400 C and pressures up to 290 bar. This model is truly a versatile solution,
More informationSTANDARD SPECIFICATIONS
CFW1000 C C C C CFW1000 CFW1 Description Installation 2 Horizontal type 4 Vertical Indicator 1 20 C water calibration 2 7 C and 60 C water, double scale 1 Scale range 1 See right table Scale range 2 Scale
More informationFlow Measurement SITRANS F C
Siemens G 2014 SITRNS C Overview The main applications of the Coriolis flowmeter can be found in all industries, such as: Chemical and pharma Detergents, bulk chemicals, pharmaceuticals, acids, alkalis
More informationRHM 04 - Universal Coriolis Mass Flowmeter with particular Fast Response
RHM 04 - Universal Coriolis Mass Flowmeter with particular Fast Response The RHM 04 can measure flow rates up to 10 kg/min (21 lb/min) with extremely fast response times and excellent repeatability. A
More informationUltimate Low Flow Coriolis Mass Flowmeter
RHM 015 - Ultimate Low Flow Coriolis Mass Flowmeter The RHM 015 can reliably measure flow rates as low as 1 g/min (0.002 lb/min). With its extremely wide turn-down ratio of 300 to 1, this model is perfect
More informationDigital Vortex Flowmeter. digitalyewflo. Digital Vortex Flowmeter. Series
Digital Vortex meter digitalyewflo Digital Vortex meter Series Unrivaled Performance, Functionality and Ease of Use Series Standard Type / Multi-variable Type High Temperature / Cryogenic Type Reduced
More informationO-180/780 Series ORIFLO METER COST EFECTIVE FLOW MEASUREMENT FOR LIQUIDS AND GASES GENERAL FEATURES MAIN APPLICATIONS
COST EFECTIVE FLOW MEASUREMENT FOR LIQUIDS AND GASES O-18/78 Series ORIFLO METER GENERAL O Series ORIFLO METER is a By-pass Orifice type flowmeter. Small sized variable flowmeter is installed onto measuring
More informationCDT1000 Series QUICK FLOW. Digital Flowmeter for Air Conditioning Application OUTLINE FEATURES STANDARD SPECIFICATION
QUICK FLOW CDT1 Series Digital Flowmeter for Air Conditioning Application OUTLINE CDT1 is a new series of flowmeter which combines a multidigital indicator with a pitot tube. CDT1 detects the differential
More informationProduct Data Sheet PS February Model D and DT. Mass Flow and Density Sensors.
Product Data Sheet PS 00388 February 2002 Model D and DT Mass Flow and Density Sensors www.micromotion.com Model D and DT sensors Micro Motion Model D sensors set the standard for Coriolis flowmeters nearly
More informationWaterMAG. Electromagnetic Flowmeter for Water Applications. Model MCB10A OVERVIEW APPLICATIONS FEATURES. No. SS2-MCB
WaterMAG Electromagnetic Flowmeter for Water Applications OVERVIEW The WaterMAG is an electromagnetic flowmeter for water measurement applications based on field proven Azbil Corporation's technologies.
More informationCoriolis Mass Flowmeter for low flow measurements
RHM 03 - Flexible Coriolis Mass Flowmeter for low flow measurements The RHM 03 can measure flow rates up to 5 kg/min (11 lb/min) with temperatures in excess of 400 C and pressures to 868 bar. This model
More informationFT-1000/FP-1000 FLOAT TYPE TANK GAUGES SIMPLE, RELIABLE, COST EFFECTIVE. The FT-1000 or FP-1000 series is a mechanical level gauge with a float.
SIMPLE, RELIABLE, COST EFFECTIVE FT-1000/FP-1000 FLOAT TYPE TANK GAUGES The FT-1000 or FP-1000 series is a mechanical level gauge with a float. The FT-1000 is a conventional float-tape level gauge with
More informationDesign and application
Design and application The function of the SGM is based on the variable area float principle. In all cases where a dependable device is required for indicating instantaneous values and monitoring the flow
More informationOPTIGAS 4010C Technical Datasheet
OPTIGAS 4010C Technical Datasheet Sensor for gas dispenser applications Compact design for easy istallation High accuracy with wide measuring range Designed to fit existing dispensers The documentation
More informationOPTIGAS 4010C Technical Datasheet
OPTIGAS 4010C Technical Datasheet Sensor for gas dispenser applications Compact design for easy istallation High accuracy with wide measuring range Designed to fit existing dispensers The documentation
More informationUCM -04A/06A RoHS compliance
Converter integrate type ultrasonic flowmeter -4A/6A RoHS compliance ULTRASONIC COMPACT METER LE The -4A/6A is the converter integrate type ultrasonic flowmeter for small flow that offers precise an stable
More informationRHM 04. Universal Coriolis Mass Flowmeter with particular Fast Response. Applications. Features. Advantages
RHM 04 Universal Coriolis Mass Flowmeter with particular Fast Response The RHM 04 can measure flow rates up to 10 kg/min (22 lb/min) with extremely fast response times and excellent repeatability. A true
More informationHDT1000 series ORIFLO METER. Multi-function Digital Flowmeter OUTLINE STANDARD SPECIFICATION FEATURES MAIN APPLICATIONS INDICATOR SPECIFICATION
ORIFO METER HDT series Multifunction Digital Flowmeter OUTINE HDT is a new series Oriflo meter combining orifice plate with multidigital indicator. HDT detects differential pressure exerted by flow velocity
More informationHENRI Flowmeter for Pulp Slurry
MagneW 3000 PLUS Smart Electromagnetic Flowmeter HENRI Flowmeter for Pulp Slurry Model MGH14 (onverter) / MGH18 (Detector) OVERVIEW The MagneW 3000 PLUS HENRI (High-Energy Noise-Resistant Instrument) flowmeter
More informationRHM015. Ultimate Performance Coriolis Mass Flow Meter for Critical Ultra Low Flow Applications. Features. Applications. Benefits
RHM015 Ultimate Performance Coriolis Mass Flow Meter for Critical Ultra Low Flow Applications Features Standard pressure ratings up to 752 bar (10907 psi) Temperature ratings from -196 to 350 C (-320 to
More informationSERIES 454FTB-WGF TECHNICAL SPECIFICATIONS
Complex Technology Made Simple Insertion Flow Meter SERIES 454FTB-WGF TECHNICL SPECIFICTIONS The Kurz WGF single point insertion flow meter for wet gas environments includes the qualities and features
More informationRHM 03. Flexible Coriolis Mass Flowmeter for low flow measurements. Applications. Features. Advantages
RHM 03 Flexible Coriolis Mass Flowmeter for low flow measurements The RHM 03 can measure flow rates up to 5 kg/min (11 lb/min) with temperatures in excess of 400 C and pressures to 868 bar. This model
More informationRHM The world s largest Coriolis Mass Flowmeter for flow rates up to kg/min
RHM 160 - The world s largest Coriolis Mass Flowmeter for flow rates up to 25000 kg/min The RHM 160 can measure flow rates up to 1500 t/hr with the patented Omega shape meter technology manufactured by
More informationSmart Pressure Transmitter
DOC. NO.: C3200L-E16B Smart Pressure Transmitter with Diaphragm Seal MODEL APT3200L DUON System Co., Ltd. 298-29, GONDAN-RO, GUNPO-SI, GYEONGGI-DO, KOREA 15809 Tel : +82-31-3-6100 Fax : +82-31-29-7200
More informationDensity Solution. TDF Series. Direct Insertion Density Meter. Characteristics
Density Solution TDF Series Direct Insertion Density Meter Xi an Tosilon Automation Co., Ltd No.299, Daqing Rd, Lianhu District, Xi'an Shaanxi, China Tel: +86-29-8823 8550 info@tosilon.com; www.tosilon.com
More informationSmart Pressure Transmitter
DOC. O.: C3700-L-E16A Smart Pressure Transmitter with Diaphragm Seal MODEL APT3700-L 298-29, GODA-RO, GUPO-SI, GYEOGGI-DO, KOREA 15809 Tel : +82-31-3-6100 Fax : +82-31-29-7200 E-mail: autrol@duon.co.kr,
More informationRHM08. Versatile Coriolis Mass Flow Meter. Features. Applications. Benefits
RHM08 Versatile Coriolis Mass Flow Meter Features Standard pressure ratings up to 1254 bar (18188 psi) Temperature ratings from -196 to 350 C (-320 to 662 F) Mass flow uncertainty down to 0.10% Repeatability
More informationRHM04. Compact Coriolis Flow Sensor With Enhanced Performance. Features. Applications. Benefits
RHM04 Compact Coriolis Flow Sensor With Enhanced Performance Features Standard high pressure versions up to 1067 bar (15475 psi) Temperature ratings from -196 to 350 C (-320 to 662 F) Mass flow uncertainty
More informationAssembly. 1 Compact version with valve plug 2 Short tube version with cable 3 Compact version with M12 plug 4 Short tube version with M12 plug
Vibration Limit Switch Features Limit switch for liquids External function test with test magnet Onsite function check possible thanks to LED indication Large selection of process connections for hassle-free
More informationSmart Pressure Transmitter
DOC. NO.: C3500L-E16A Smart Pressure Transmitter with Diaphragm Seal MODEL APT3500L 298-29, GONDAN-RO, GUNPO-SI, GYEONGGI-DO, KOREA 15809 Tel : +82-31-3-6100 Fax : +82-31-29-7200 E-mail: autrol@duon.co.kr,
More informationRHM 80 - Coriolis Mass Flowmeter for large flow applications optional heavy duty version
RHM 80 - Coriolis Mass Flowmeter for large flow applications optional heavy duty version The RHM 80 can measure flow rates up to 480 t/hr with the patented Omega shape meter technology manufactured by
More informationRHM 015. Ultimate Low Flow Coriolis Mass Flowmeter. Applications. Features. Advantages
RHM 015 Ultimate Low Flow Coriolis Mass Flowmeter The RHM 015 can reliably measure flow rates as low as 1 g/min (0.002 lb/min). With its extremely wide turn-down ratio of 300 to 1, this model is perfect
More informationORIFLO CONTENTS COST EFECTIVE FLOW MEASUREMENT FOR LIQUIDS AND GASES INTEGRATED ORIFICE FLOWMETERS GENERAL FEATURES MAIN APPLICATIONS
COST EFECTIVE FLOW MEASUREMENT FOR LIQUIDS AND GASES ORIFLO INTEGRATED ORIFICE FLOWMETERS GENERAL O series ORIFLO METER is a By-pass Orifice type flowmeter. Small sized variable flowmeter is installed
More informationFlow Measurement SITRANS F C. Flow sensor MASS 2100 DI 3 to DI 40. 4/180 Siemens FI
Siemens AG Flow sensor MASS DI 3 to DI 0 Overview MASS DI 3 to DI 0 is suitable for accurate mass flow measurement of a variety of liquids and gases. The sensor offers superior performance in terms of
More informationA Higher Level of Performance. Data Sheet. Centurion. Guided Radar. CGR Series. For more information, please visit >
Higher Level of Performance Data Sheet Centurion Guided Radar CGR Series For more information, please visit > www.hawkmeasure.com / Dimensions Centurion Guided Wave Radar Radar Principle of Operation Guided-wave
More informationGS.No.GBN120E 9. Liquid. Gas. High Performance Coriolis Flowmeters GENERAL
iquid Gas High Performance Coriolis Flowmeters GENERA SPECIFICATION GS.No.GBN120E 9 arge sized type ow temperature explosionproof service type High temperature service type Extra low flow type ow flow
More informationRHM Coriolis Mass Flowmeter for high Flow Applications
RHM 100 - Coriolis Mass Flowmeter for high Flow Applications The RHM 100 can measure up to 720 t/hr with the superior and patended Omega shape meter technology manufactured by rheonik, the mass flowmeter
More informationFP-4000 Series FLOAT LEVEL SWITCH OUTLINE MAIN APPLICATIONS STANDARD SPECIFICATION
FOR MULTIPOINT LEVEL ALARM ETECTION BY ONE UNIT FP- Series FLOAT LEVEL SWITC OUTLINE The FP- series is a float level switch, which is installe through the tank nozzle on tanks an/or pits. Level alarm etection
More informationDetector (for water measurement applications)
WaterMAG Smart Electromagnetic Flowmeter Detector (for water measurement applications) Model MGW18 OVERVIEW The WaterMAG electromagnetic flowmeter detector is a high performance, highly reliable flowmeter
More informationRHM 03 a1 - (low stress in welds and increased wall thickness against abrasion) RHM bar APPLICATIONS. Batching Dosing. Injections Filling
RHM 03 a1 - RHM 03 0.05 ~ 5 kg/min (11 lb/min), -200 ~ 400 C, APPLICATIONS Batching Dosing Injections Filling FEATURES 868 bar 0.005 kg/min ~ 5 kg/min (11 lb/min) 0.1% 0.05% process connection. ADVANTAGES
More informationSmart Pressure Transmitter
DOC. NO.: C3100L-E16B Smart Pressure Transmitter with Diaphragm Seal MODEL APT3100L DUON System Co., Ltd. 298-29, GONDAN-RO, GUNPO-SI, GYEONGGI-DO, KOREA 15809 Tel : +82-31-3-6100 Fax : +82-31-29-7200
More informationMicro Motion Model D and DL Coriolis Flow and Density Meters
Product Data Sheet PS-00388, Rev. F April 2013 Micro Motion Model D and DL Coriolis Flow and Density Meters Micro Motion Model D and DL sensors provide flow and density measurement for liquids, gases,
More informationLevel Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. icenta Controls Ltd
Pointek CLS200 Standard Overview Configuration Installation Pointek CLS200 (standard version) is a versatile inverse frequency shift capacitance level switch with optional rod/cable choices liquids, solids,
More informationRHM 06. One of the Most Popular Rheonik Mass Flowmeter Serving Thousands of Worldwide Applications. Applications. Advantages.
RHM 06 One of the Most Popular Rheonik Mass Flowmeter Serving Thousands of Worldwide Applications The RHM 06 can measure flow rates up to 25 kg/min (55 lb/min) with temperatures in excess of 350 C and
More informationRHM 08. One of the most popular Rheonik Mass Flowmeter serving thousands of worldwide applications. Applications. Advantages.
RHM 08 One of the most popular Rheonik Mass Flowmeter serving thousands of worldwide applications The RHM 08 can measure flow rates up to 50 kg/min (110 lb/min) with temperatures in excess of 350 C and
More informationMagneW Neo+ Two-wire Electromagnetic Flowmeter Integral type TIIS Explosion-protected Apparatus
MagneW Neo+ Two-wire Electromagnetic Flowmeter Integral type TIIS Explosion-protected Apparatus OVERVIEW The MagneW Neo+ is a high performance two wired electromagnetic flowmeter based on field proven
More informationLevel Switch MPC2000 MPC2
Technical Information Level Switch MPC2000 MPC2 Displacement Type Level Switch Application MPC series level controllers are displacement type instruments for tank installation. MPC provides 1to 4 control
More informationDifferential pressure transmitter PASCAL Ci4 Delta P
Differential pressure transmitter PASCAL Ci4 Delta P for high static working pressure, PN 160, Type series CI4340 Features Simultaneous display of differential pressure and static pressure Long-term stability
More informationNow available with MVD Technology! ELITE Mass Flow and Density Meters
Product Data Sheet PS-00374 July 2001 Now available with MVD Technology! ELITE Mass Flow and Density Meters Micro Motion ELITE Meters Experience the most accurate Coriolis meters available today. Micro
More informationLevel Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. 4/18 Siemens FI Overview.
Pointek CLS200 Standard Overview Configuration Installation Pointek CLS200 (standard version) is a versatile inverse frequency shift capacitance level switch with optional rod/cable choices liquids, solids,
More informationLevel Measurement Point level measurement - RF Capacitance switches
Pointek CLS200 - Standard Overview Configuration Installation Pointek CLS200 (standard version) is a versatile inverse frequency shift capacitance level and material detection switch with optional rod/cable
More informationRHM 60. Coriolis Mass Flowmeter for Medium Flow also Suited for High Pressure Applications. Applications. Advantages. Features
RHM 60 Coriolis Mass Flowmeter for Medium Flow also Suited for High Pressure Applications The RHM 60 can measure flow rates up to 180 t/hr with the patented Omega shape meter technology, manufactured by
More informationCoriolis Mass Flow Measuring System promass 64
Technical Information TI 038D/06/en No. 50084730 Coriolis Mass Flow Measuring System promass 64 Mass and volumetric measurement for custody transfer procedures (PTB and NMi approvals according to OIML
More informationGeneral Specifications
General Specifications Model UYF200, UYF21 Ultrasonic Vortex meter OVERVIEW When a vortex shedder is installed in a process flow line, the regular Karman vortex street is shed at the downstream of the
More informationPressure transducer DMU 01K Compact version
Pressure transducer DMU 01K Compact version Dimensions (in mm) Wiring diagram 8 Application Special OEM unit. For electronic pressure measurement in industrial or HVAC applications (such as hydraulic,
More informationA Higher Level of Performance. Data Sheet. Centurion. Guided Radar. CGR Series. For more information, please visit >
A Higher Level of Performance Data Sheet Centurion Guided Radar CGR Series For more information, please visit > www.hawkmeasure.com / Dimensions Centurion Guided Wave Radar Radar Principle of Operation
More informationSITRANS F C MASSFLO Practical examples of ordering. MASS2100 & MASS6000 IP67 Compact mounted
SITRNS F C MSSFLO MSS2100 & MSS6000 IP67 Compact mounted Mass 2100 sensor DI 3 - DI 40 MSS 6000 IP67 transmitter. Use ordering code FI 01 Catalogue p. 4/140 MSS system: 7ME4100-2EC21-2D1 FI 01 catalogue
More informationABB Instrumentation. 50T Series Transmitters Model 54G/A gauge/absolute pressure transmitter for sanitary use. Specification sheet
Specification sheet 50T Series Transmitters Model 54G/A gauge/absolute pressure transmitter for sanitary use Ranges : - 100 to 4000 kpa - 1 to 40 bar - 14.5 to 600 psi Base accuracy : 0.2%(BFSL) Piezoresistive
More informationMicro Motion 7827 Digital Viscosity Meter
Product Data Sheet PS-001217, Rev. C April 2013 Micro Motion 7827 Digital Viscosity Meter Micro Motion viscosity meters are built to tackle the most demanding process and control applications. Rugged and
More informationLiquid Turbine Flow Meter OwnerÊs Manual
Liquid Turbine Flow Meter OwnerÊs Manual Manual LWGY-G Rev.1.0 Content 1.0 GENERAL INFORMATION... 1 2.0 SPECIFICATIONS... 2 3.0 OPERATION CONDITIONS... 3 4.0 CAUTIONS FOR INSTALLATION... 4 5.0 DIMENSION...
More informationOptions guide. Electromagnetic flowmeters. M9xx
Options guide Electromagnetic flowmeters M9xx Ordering codes Model Description M 910 -V0 0 0 0 DN50 PN16 Example Sensor M Basic Ex Ex certified (remote version only) Transmitter 910E Economic version 910
More informationMagnetic float switch For vertical installation Model FLS (models with Ex approval: 60, AL-ADF)
Level measurement Magnetic float switch For vertical installation Model FLS (models with Ex approval: 60, AL-ADF) TC Fluid Control WIKA data sheet LM LM 3001 30.01 for further approvals see page 3 Applications
More informationMicro Motion F-Series Coriolis Flow and Density Meters
Product Data Sheet PS-00629, Rev. E May 2007 Micro Motion F-Series Coriolis Flow and Density Meters Micro Motion F-Series Coriolis meters offer highly accurate mass flow, volume flow, and density measurement
More informationMicro Motion T-Series Coriolis Flow and Density Meters
Micro Motion T-Series Coriolis Flow and Density Meters Product Data Sheet PS-00371, Rev K April 2018 Superior flow measurement in a single straight tube flow meter Built-in balance bar provides the best
More informationMicro Motion ELITE High Capacity Coriolis Flow and Density Meters
Product Data Sheet PS-001041, Rev. L April 2013 Micro Motion ELITE High Capacity Coriolis Flow and Density Meters Micro Motion ELITE High Capacity Coriolis meters offer unparalleled flow and density measurement
More informationSatellite photo of cloud vortices caused by a mountain (Courtesy of our friends at NASA) tekvorx Operation Showing Simplified Construction
Sensing the pulse of industry tekvorx TV01 Multivariable Vortex flow Sensors Vortex flow sensors derive their name from a natural phenomenon of fluid dynamics. When a gas or relatively low viscosity liquid
More informationMicro Motion ELITE High Capacity Coriolis Flow and Density Meters
Product Data Sheet PS-001041, Rev. F February 2010 Micro Motion ELITE High Capacity Coriolis Flow and Density Meters Micro Motion ELITE High Capacity Coriolis meters offer unparalleled flow and density
More information