VFM4070C SWIRLMAX. Vortex Flowmeter OUTLINE FEATURES OPERATING PRINCIPLE STANDARED SPECIFICATION. General Specification. Sensor Specification
|
|
- Amy Cobb
- 6 years ago
- Views:
Transcription
1 SWIRMAX VFM4070C Vortex Flowmeter OUTINE SWIRMAX is 2-wire, all-in-one type vortex flowmeter with both temperature and pressure sensors integrally mounted into the housing. It allows temperature and pressure compensation of steam and gas flow measurement without additional sensors. It is best suited for energy management of steam and gas flow. FEATURES Wide variety of fluids can be measured: steam, gases, and liquids services. Temperature compensation of saturated steam included as standard The flowmeter has a temperature sensor and amplifier where density table of saturated steam is memorized. It outputs the flow rate of saturated steam compensated by actual temperature. Thus, it gives mass flow rate as standard. Pressure sensor provided as an option A pressure sensor can be installed as an option. The flowmeter could compensate pressure and temperature changes of steam and gas without providing extra sensors and compensation unit. Corrosion resistant all stainless steel construction All wet parts made of welded stainless steel construction is robust and corrosion/heat resistant. Diameter reduced version now available for Flange version Constricted meter size of measuring part is available to make measurement of low flow rate possible. Thereby diameter reduction up to two sizes is possible. Stable reading by Intelligent Signal Processing (ISP) The unique ISP gives stable and reliable readings by compensating external disturbances. Reliable construction Reliable and maintenance free flowmeter with no moving parts. ATEX and TIIS explosionproof versions are available. OPERATING PRINCIPE An object in the flowing fluid generates Karman vortexes in regular cycle, alternatively at each side of the object downstream. The generated vortex frequency is proportional to the flow velocity. The frequency of Karman vortex, detected by a piezoelectric element in flow sensing unit of VFM4070C, is converted to the flow rate for output signal. The flow sensing unit, having a Pt1000Ω temperature sensor and saturated steam table, gives automatic temperature compensation of steam flow rate by sensing the fluid temperature. Furthermore, it provides automatic temperature and pressure compensation of gases and superheated steam by equipping with a pressure sensor as an option. STANDARED SPECIFICATION v b S v f = b f : Vortex frequency v : Flow velocity Pressure sensor S : Constant of proportion i.e. Strouhal number b : Width of vortex generating object Vortex sensor Vortex generator b General Specification Meter size Flange type : 15, 25, 40,, 80, 100, 1, 200, 2, 300mm Wafer type : 15, 25, 40,, 80, 100mm Protection class : IP66 / 67 (IEC 529) Ambient temperature : 40 to +85 C *Refer to Explosionproof specifications for the ambient temperature. Sensor Specification Wetted parts : Stainless steel (Equivalent to 316) [Metering tube, Flange, Vortex sensor, Gasket for vortex sensor] Process connection : Flange or Wafer connection Flange : JIS10K/20K ASME class 1/300/0 Temperature sensor : Resistance temperature sensor Pt1000Ω integrated (Standard) Pressure sensor : Pressure sensor integrated (Option)
2 Fluid Specification Fluid : Gas, Steam, iquid Temperature : 40 to +240 C * Refer to "Explosionproof specifications" for the fluid temperature. Pressure : Flange rating pressure or less (Max.10MPa) Viscosity : < 10 mpa s Reynolds number : to Converter Specification ousing material : Aluminium alloy Painting : Siloxane coating Color : Grey (Converter ousing) Jade green (Converter cover) Cable entry : G1/2 female screw, 1/2NPT or M20 watertight glands Power supply : 24V DC (14 to 36V DC) * Refer to "Explosionproof specifications" for the power supply. Display : CD 2 lines Selectable indication of flow rate, total flow, temperature, vortex frequency value, pressure (option). Output Current output Output : 2-wire 4 to 20mA DC Allowable load resistance : R = (E-14) / 0.022Ω E; Power voltage (V) Pulse output Output type : Open collector (Normal closed) Pulse rate : Max. 0.5z Pulse width : Min.2ms oad rating : Max. 36V DC, 10 to 100mA Note: Secure minimum current 10mA when the contact is ON to make proper operation. * Refer to "Explosionproof specifications" for the maximum load rating. Flow rate compensation operation function : Compensation for temperature function of saturated steam (Standard function) Temperature and pressure compensation function of saturated steam and Gas (Option) ART communication : Standard Damping time constant : 0 to 20s (Variable) Test function : Equipped with simulated current output and pulse output functions. Burnout : Either 22 ma or 3.55 ma current can be output at error mode. Accuracy (Based on the standard condition) Re : ±0.75% of R.D. (iquid) ±1% of R.D. (Gas, Steam) < Re < : ±2% of R.D. (iquid, Gas, Steam) [With temperature and pressure compensation] Re : ±1.5% of R.D. (Gas, Steam) < Re < : ±2.5% of R.D. (Gas, Steam) * Accuracy is expressed as % of the readings. * The figure of ±0.05% of full scale shall be added to above figures to get total accuracy of current output. Explosionproof specifications ATEX : II 2G Ex d ia [ia] IIC T6 TIIS : Ex d ia [ia] IIC T4 for converter : Ex ia IIC T4 for terminal box and detector For further details refer to Explosionproof specifications on page 11. Measurable Flow Range Measurable minimum and maximum flow velocity [ρ: Fluid density (Unit : kg/m 3 )] iquid Gas, Steam Min. velocity The biggest fi gure of given results from following calculations. Flow velocity given from the value 0.5 (998 /ρ) 0.5 Flow velocity when Reynolds number is 10, m/s The biggest fi gure of given results from following calculations. Flow velocity given from the value 6 (1.29 /ρ) 0.5 Flow velocity when Reynolds number is 10,000 2m/s (15mm: 3m/s) Measurable flow range for water [Temperature: 20 C] Size Flow range (m 3 /h) 0.46 to to to to to to to to to to 1781 Max. velocity The smallest fi gure of given results from following calculations. Flow velocity given from the value 7 (998 /ρ) m/s The smallest fi gure of given results from following calculations. Flow velocity given from the value 7 (998 /ρ) m/s (15mm : 45m/s) (25mm : 70m/s) Note 1) The fi gures in ( ) mean the minimum fl ow rate when the accuracy is ±1.5%. Other fi gures mean the minimum and maximum fl ow rate when the accuracy is 0.75%. 2 TOKYO KEISO CO., TD. TG-EM166E-7
3 Measurable flow range for Air [Temperature: 0 C] Meter size Flow range (m 3 /h(nor)) 0 MPa 0.1 MPa 0.2 MPa 0.3 MPa 0.4 MPa 0.5 MPa 0.6 MPa 0.8 MPa 1.0 MPa 1.5 MPa 2.0 MPa (6.1) 12.1 (6.2) 12.1 (7.5) 12.1 (8.7) 12.1 (10.8) (9.8) 18.1 (13.8) 18.1 (16.9) (24.5) Note 1) The figures in ( ) mean the minimum flow rate when the accuracy is ±2.0% at ordinary case and ±2.5% at temperature/pressure compensation case. Other figures mean the minimum and maximum flow rate when the accuracy is ±1.0% at ordinary case and ±1.5% at temperature/pressure compensation case. TG-EM166E-7 TOKYO KEISO CO., TD. 3
4 Measurable flow range for Saturated steam Meter size Flow range (kg/h)) 0.1 MPa 0.2 MPa 0.3 MPa 0.4 MPa 0.5 MPa 0.6 MPa 0.8 MPa 1.0 MPa 1.5 MPa 2.0 MPa (5.9) 11.8 (6.4) 12.2 (7.3) 12.5 (8.1) 12.8 (8.9) 13.0 (9.5) 13.2 (10.7) 13.5 (12.3) (11.8) 17.7 (14.3) 18.3 (16.4) 18.8 (18.2) Note 1) The figures in ( ) mean the minimum flow rate when the accuracy is ±2.0% at ordinary case and ±2.5% at temperature/pressure compensation case. Other figures mean the minimum and maximum flow rate when the accuracy is ±1.0% at ordinary case and ±1.5% at temperature/pressure compensation case. 4 TOKYO KEISO CO., TD. TG-EM166E-7
5 PRESSURE OSS ΔP = C ρ 10 4 ΔP : Pressure loss (kpa) ρ: Density (kg/m 3 ) 1000 Relationship between pressure loss and flow rate DN15 DN25 DN40 DN DN80 DN100 DN1 DN200 Pressure loss coefficient (C) Flow rate for liquid (m 3 /h) ΔP = C ρ 10 4 ΔP : Pressure loss (kpa) ρ: Density (kg/m 3 ) Relationship between pressure loss and flow rate DN15 DN25 DN40 DN DN80 DN100 DN1 DN200 Pressure loss coefficient (C) Flow rate for Gas and Steam (m 3 /h) Note) The above data are the pressure losses for the same connection size and meter size. If you require pressure loss of the Diameter reduced version, please contact us or your local representative. TG-EM166E-7 TOKYO KEISO CO., TD. 5
6 DIMENSIONS Flange Type Wafer Type Without pressure sensor Without pressure sensor 107 (26) (26) D With pressure sensor 107 (26) l 85 With pressure sensor 107 (26) l 85 D Size (mm) Dimensions (mm) Weight (Approx. kg) *1 l *1: Weight is for JIS10K flange type. Size (mm) Dimensions (mm) D l Weight (Approx. kg) TOKYO KEISO CO., TD. TG-EM166E-7
7 MOUNTING POSITION OF CONVERTER AND DISPAY With pressure sensor Without pressure sensor Version A (Standard) Version B Version A (Standard) Version B Version C Version D Version C Version D * The arrow indicates the flow direction. * The arrow indicates the flow direction. * The mounting position of pressure sensor of Version B and D is the opposite side of display. WIRING Power supply and current output Power supply Receiver Current output (2-wire, 4 to 20mA) When pulse output is required A A + B B + STANDARD ACCESSORIES Centering ring : 2 (Wafer type) Magnet for data setting : 1 Data sheet for setting : 1 Instruction manual : 1 OPTION G1/2 watertight glands for cable entry: 1 set [Symbol : WG] No converter data (parameter) setting [Symbol : NS] The instrument is delivered after standard setting by Tokyo Keiso Co., td. The customers are kindly requested to set as necessary for example measuring flow range. Power Receiver supply Current output (2-wire, 4 to 20mA) Pulse output (Open collector) + oad rating : Max. 36 VDC, 10 to 100mA Note : Secure minimum current 10mA when the contact is ON to make proper operation. When used as intrinsically safe circuit A A + B B + ORDERING INSTRUCTIONS 1. Model and spec. code Example : Model : VFM4070C Spec. code : VG1742N Flow rate (Full scale) (Unnecessary when option is NS.) 3. Mounting position of converter and display (Version A/B/C/D: Refer to page 7.) 4. Option (Specify if necessary.) Specify the symbol with reference to the option. 5. Fluid name, Temperature, Pressure, Density, Viscosity Non-hazardous area azardous area Power supply and current output, 24V DC Safety Receiver barrier (4-20mA) Safety barrier Pulse output, Transistor contact output A A+ B B+ Install an intrinsic safety barrier when VFM4070C is used as the intrinsically safe circuit. Comply with the requirements of the intrinsic safety barrier. When an isolation barrier is used, check if the power supply meets the requirements of the isolation barrier. TG-EM166E-7 TOKYO KEISO CO., TD. 7
8 MODE CODE Model : VFM4070C (Flange type) Spec. code VG174 A Description Standard 2 15mm / 1/2" 4 25mm / 1" 6 40mm / 1-1/2" 7 mm / 2" A 80mm / 3" Connection size B 100mm / 4" D 1mm / 6" E 200mm / 8" F 2mm / 10" G 300mm / 12" A ASME class 1 B ASME class 300 Flange D ASME class 0 M JIS20K N JIS10K *1 Type A Flange Meter size Metering tube / Gasket for vortex sensor / Gasket for press sensor 2 15mm / 1/2" 4 25mm / 1" 6 40mm / 1-1/2" 7 mm / 2" A 80mm / 3" B 100mm / 4" D 1mm / 6" E 200mm / 8" F 2mm / 10" G 300mm / 12" 1 SS316 / SS316 / FPM *2 3 SS316 / SS316 / FFKM *3 Selectable two diameter sizes reducted from a connection size ousing material 0 Aluminium alloy With temp. compensation function (for saturated steam), 0 non-compensation function (for gas and liquid) Version 1 With temp. and press. compensation function (for superheated steam) *5 2 With temp. and press. compensation function (for gas) *5 Type 1 Integrated 0 General type (Non Ex-proof) Explosionproof specifi cation 1 ATEX 9 TIIS 0 None 3 Pressure sensor Max. 0.4MPa 4 Pressure sensor Max. 0.6MPa 5 Pressure sensor Max. 1MPa 6 Pressure sensor Max. 1.6MPa 7 Pressure sensor Max. 2.5MPa 8 Pressure sensor Max. 4MPa A Pressure sensor Max. 6MPa Pressure sensor B Pressure sensor Max. 10MPa C Pressure sensor, With valve Max. 0.4MPa D Pressure sensor, With valve Max. 0.6MPa E Pressure sensor, With valve Max. 1MPa F Pressure sensor, With valve Max. 1.6MPa G Pressure sensor, With valve Max. 2.5MPa Pressure sensor, With valve Max. 4MPa K Pressure sensor, With valve Max. 6MPa Pressure sensor, With valve Max. 10MPa Display 1 With CD display 1 1/2" NPT Cable entry 2 G1/2 3 M20 with watertight glands (Fixed code) always Special feature (Blank) None / Z Involved *4 *1 JIS20K fl anges are used as standard in common with JIS10K fl anges for both connection sizes between 15mm and 40mm. *2 FPM (Fluorocarbon rubber) *3 FKKM (Perfl uoroelastomer) *4 The special requirements not specifi ed by above codes shall be described concretely by adding code "/z" at the end of code designation. *5 Selectable if with press. sensor. 8 TOKYO KEISO CO., TD. TG-EM166E-7
9 Mode l: VFM4070C (Wafer type) Spec. code VG Description Standard 2 15mm / 1/2" 4 25mm / 1" 6 40mm / 1-1/2" Connection size 7 mm / 2" A 80mm / 3" B 100mm / 4" A ASME class 1 B ASME class 300 Flange D ASME class 0 M JIS20K N JIS10K Type 0 Wafer 2 15mm / 1/2" Meter size Metering tube / Gasket for vortex sensor / Gasket for press sensor 4 25mm / 1" 6 40mm / 1-1/2" 7 mm / 2" A 80mm / 3" B 100mm / 4" 1 SS316 / SS316 / FPM *1 3 SS316 / SS316 / FFKM *2 The same size as a connection size can be chosen. ousing material 0 Aluminium alloy With temp. compensation function (for saturated steam), 0 non-compensation function (for gas and liquid) Version 1 With temp. and press. compensation function (for superheated steam) *4 2 With temp. and press. compensation function (for gas) *4 Type 1 Integrated 0 General type (Non Ex-proof) Explosionproof specifi cation 1 ATEX 9 TIIS 0 None 3 Pressure sensor Max. 0.4MPa 4 Pressure sensor Max. 0.6MPa 5 Pressure sensor Max. 1MPa 6 Pressure sensor Max. 1.6MPa 7 Pressure sensor Max. 2.5MPa 8 Pressure sensor Max. 4MPa A Pressure sensor Max. 6MPa Pressure sensor B Pressure sensor Max. 10MPa C Pressure sensor, With valve Max. 0.4MPa D Pressure sensor, With valve Max. 0.6MPa E Pressure sensor, With valve Max. 1MPa F Pressure sensor, With valve Max. 1.6MPa G Pressure sensor, With valve Max. 2.5MPa Pressure sensor, With valve Max. 4MPa K Pressure sensor, With valve Max. 6MPa Pressure sensor, With valve Max. 10MPa Display 1 With CD display 1 1/2" NPT Cable entry 2 G1/2 3 M20 with water tight glands (Fixed code) always Special feature (Blank) None / Z Involved *3 *1 FPM (Fluorocarbon rubber) *2 FKKM (Perfl uoroelastomer) *3 The special requirements not specifi ed by above codes shall be described concretely by adding code "/z" at the end of code designation. *4 Selectable if with press. sensor. TG-EM166E-7 TOKYO KEISO CO., TD. 9
10 REQUIRED STRAIGT ENGT <Upstream> Upstream piping arrangement Required upstream straight length More than 20D One reducer More than 20D One elbow More than 30D Two elbows in same plane More than 40D Two elbows in different planes More than D Control valve More than 20D Fully opened on-off valve Note 1) "D" means meter size. <Downstream> Downstream piping arrangement Required downstream straight length More than 5D One elbow or control valve or reducer More than 5 to 6D Measuring tap Measuring tap Note 1) "D" means meter size. 10 TOKYO KEISO CO., TD. TG-EM166E-7
11 Explosionproof specifications Certified by TIIS Model : VFM4070C-JEx Type of protection and class : Ex d ia [ia] IIC T4 for converter : Ex ia IIC T4 for terminal box and detector Certification No. : TC19097 Ambient temperature :-20 to C Fluid temperature :-40 to C Power supply : 24V DC (14 to 30V) Pulse output load rating : Max. 30V DC, 10 to 100mA Note: Secure minimum current 10mA when the contact is ON to make proper operation. Intrinsically safe circuit rating : Current output terminal A+ and A, Pulse output terminal B+ and B Max. voltage for intrinsically safe circuit (Ui) = 30V Max. Current for intrinsically safe circuit (Ii) = 100mA Max. Power consumption for intrinsically safe circuit (Pi) = 1W Capacitance inside intrinsically safe circuit (Ci) = 15nF Inductance intrinsically safe circuit (i) = 0μ Certified by ATEX Model : VFM4070C Type of protection and class : II2 G Ex d ia [ia] IIC T6 Ambient temperature :-25 C to the temperature as shown below table Fluid temperature :-40 C to the temperature as shown below table [C] T6 T5 T4 Temperature class T3 T2, T1 Ambient temperature size 15mm, 25mm * 125* 235* 180* 125* 40mm, mm mm, 100mm mm * 240* 190* 130* * Use heat resistance cable suitable for 80 C or more for field wiring. Power supply : 24V DC (14 to 30V) Pulse output load rating : Max. 30V DC, 10 to 100mA Note: Secure minimum current 10mA when the contact is ON to make proper operation. Intrinsically safe circuit rating :Current output terminal A+ and A, Pulse output terminal B+ and B Max. voltage for intrinsically safe circuit (Ui) = 30V Max. Current for intrinsically safe circuit (Ii) = 100mA Max. Power consumption for intrinsically safe circuit (Pi) = 1W Capacitance inside intrinsically safe circuit (Ci) = 15nF Inductance intrinsically safe circuit (i) = 0μ When this product is used as the intrinsically safe circuit, the safety barrier must be installed at the non-hazardous area in the 2-wire loop. One barrier for each current and pulse output is required. One barrier for current output is required when the pulse output is not used. Recommended barriers below, if required, are available as an option. For current output : Intrinsically safe isolation barrier Model KFD2-STC4-Ex1 made by P&F For pulse output : Intrinsically safe zener barrier Model Z728 made by P&F * Specification is subject to change without notice. ead Office : Shiba Toho Building, Shibakoen, Minato-ku, Tokyo Tel : (KEY) ; Fax : overseas.sales@tokyokeiso.co.jp ; UR : TG-EM166E-7 TOKYO KEISO CO., TD. 11
EGM5300C MAGMAX. Compact Electromagnetic Flowmeter GENERAL FEATURES STANDARD SPECIFICATION. General Specification
MAGMAX EGM53C Compact Electromagnetic Flowmeter GENERAL MAGMAX EGM53C is a combination of EGS5 primary head with Ceramic measuring tube and high performance converter EGC3. EGM53C with high durability
More informationEGM1100C MAGMAX. Compact Electromagnetic Flowmeter GENERAL FEATURES STANDARD SPECIFICATION. General Specification
EGMC Compact Electromagnetic Flowmeter GENERA MAGMAX EGMC is the compact type electromagnetic flowmeter with a converter EGC mounted integrally on a primary head EGS lined with fluorocarbon resin PFA.
More informationUL6300 SONICMAX. Ultrasonic Clamp-on Flowmeter OUTLINE FEATURES MEASURING PRINCIPLE
SONICMAX UL63 Ultrasonic Clamp-on Flowmeter OUTLINE SONICMAX UL63 is the ultrasonic flowmeter of the time flight system which combined the highly efficient converter (UFC3) with the clamp-on sensor (UFS6).
More informationAM-2000 series HYBRID FLOWMETER
AM- series HYBRID FLOWMETER OUTLINE AM- series is a new all metal type flowmeter. AM- series integrates formerly separate functional devices to facilitate mounting in restricted spaces. Suitable for liquid,
More informationO-1000 Series ORIFLOMETER MOST COST EFFECTIVE FLOW MEASUREMENT GENERAL STANDARD SPECIFICATIONS TYPES AND FUNCITON
MOST COST EFFECTIVE FLOW MEASUREMENT O-1000 Series ORIFLOMETER GENERAL O-1000 series ORIFLO METER is a flow meter consisting of an orifice plate and a metal tube variable area flow meter. Since the flow
More informationMASSMAX 1000 Series Straight twin tube Coriolis Mass Flowmeter
MASSMAX Series Straight twin tube Coriolis Mass Flowmeter OUTLINE MASSMAX series is the coriolis mass flowmeters developed on the theme of the straight tube model which is excellent in cost performance.
More informationAM9000 Series GENERAL FEATURES METAL TUBE VARIABLE AREA FLOWMETER
METAL TUBE VARIABLE AREA FLOWMETER AM9000 Series GENERAL The AM9000 series metal tube variable area flowmeters have the unified face-to-face dimension mm. Having developed the current well-accepted AM7000
More informationUL6300 SONICMAX. Ultrasonic Clamp-on Flowmeter OUTLINE FEATURES STANDARD SPECIFICATION. Common specification
SONICMAX UL63 Ultrasonic Clamp-on Flowmeter OUTLINE SONICMAX UL63 is the ultrasonic flowmeter of the time flight system which combined the highly efficient converter (UFC3) with the clamp-on sensor (UFS6).
More informationDigital Vortex Flowmeter. digitalyewflo. Digital Vortex Flowmeter. Series
Digital Vortex meter digitalyewflo Digital Vortex meter Series Unrivaled Performance, Functionality and Ease of Use Series Standard Type / Multi-variable Type High Temperature / Cryogenic Type Reduced
More informationVLM20 In-line Vortex Flowmeter
ocal regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without
More information1000 Series MASSMAX. Coriolis Mass Flowmeter Straight Twin Tube OUTLINE FEATURES STANDARD SPECIFICATIONS. Fluid Specifications
MSSMX Series Coriolis Mass Flowmeter Straight Twin Tube OUTLINE MSSMX series is the coriolis mass flowmeters developed on the theme of the straight tube model which is excellent in cost performance. The
More informationArmstrong In-Line and Insertion Vortex Flow Meters
Armstrong In-Line and Insertion Vortex Flow Meters Designs, materials, weights and performance ratings are approximate and subject to change without notice. Visit for up-to-date information. 1 In-Line
More informationSRT1000 Series THERMAL FLOWMETER
High-performance gas flowmeter SRT1000 Series THERMAL FLOWMETER OUTLINE Based on the long experienced know-how on the TOKYO KEISO's thermal flowmeters, SRT1000 series has enhanced its performance such
More informationVortex Flowmeters VFM 3100 F-T VFM 3100 W-T
KROHNE 10/2001 7.02313.23.00 GR/OP Vortex Flowmeters F-T W-T Variable area flowmeters Vortex flowmeters Flow controllers Electromagnetic flowmeters Ultrasonic flowmeters Mass flowmeters Level measuring
More informationHDT1000 series ORIFLO METER. Multi-function Digital Flowmeter OUTLINE STANDARD SPECIFICATION FEATURES MAIN APPLICATIONS INDICATOR SPECIFICATION
ORIFO METER HDT series Multifunction Digital Flowmeter OUTINE HDT is a new series Oriflo meter combining orifice plate with multidigital indicator. HDT detects differential pressure exerted by flow velocity
More informationVersaFlow Vortex 100 Vortex Flow Meter Specifications
VersaFlow Vortex 100 Vortex Flow Meter Specifications 34-VF-03-05 May 2011 The All-In-One Solution The VERSAFLOW is the only vortex flowmeter with integrated and temperature compensation in 2- wire technology.
More informationR-101-E GLASS TUBE FLOWMETER BEST COST PERFORMANCE GENERAL STANDARD SPECIFICTION. Max. fluid press. MPa Meter size.
BEST COST PERFORMANCE R-1-E GLASS TUBE FLOWMETER GENERAL R-1-E is a glass tube type variable area flowmeter. The flow rate is indicated by the position of float and the graduation engraved on the glass
More informationDigital Vortex Flowmeter. digitalyewflo. Digital Vortex Flowmeter. Series. Bulletin 01F06A02-00E.
Digital Vortex meter digitalyewflo Digital Vortex meter Series Bulletin 01F06A02-00E www.yokogawa.com/ Series Simple body construction for easy installation and high level of safety 2 3 Standard Type /
More informationVORTEX FLOW METTER DVH. Despriction. Advantages of the DVH Vortex Flow Meter
R VORTEX FLOW METTER DVH Measuring range: 3-8... 3 057-280 187 m3n/h Accuray: ± 0,7 % of reading (liquids) ± 1 % of reading (gases and steam) P m a x : 100 bar abs; tm ax : 400 C Connection: ANSI ½ up
More informationSTK2000/7400 Series. Flapper-type Flowmeter OUTLINE FEATURES PRINCIPLE STANDARD SPECIFICATIONS. Specifications of the metal measuring tube
STK2000/7400 Series Flapper-type Flowmeter OUTLINE The STK2000 and STK7400 are high-accuracy, high-performance, flapper-type flowmeters. The STK2000 is a local indication type, and the STK7400 is a local
More informationOPTISWIRL 4070 Technical Datasheet
OPTISWIRL 4070 Technical Datasheet Vortex flowmeter Integrated pressure and temperature compensation Temperature compensation for saturated steam included as standard All OPTISWIRL versions in 2-wire technology
More informationMultivariable Vortex Flow Meter
Multivariable Vortex Flow Meter DVH Sensor Design w/o sealing Fully welded sensor Integrated temperature and pressure measurement (optional) Calculation of mass and density possible High temperature version
More informationVortex Flowmeter. digitalyewflo. Vortex Flowmeter. Series. Bulletin 01F06A02-00E.
Vortex meter digitalyewflo Vortex meter Series Bulletin 01F06A02-00E www.yokogawa.com/fld Series Simple body construction for easy installation and high level of safety 2 Standard Type / Multi-variable
More informationF-2600 SERIES INLINE VORTEX FLOW METER
F-2600 SERIES INLINE VORTEX FLOW METER APPLICATIONS Saturated steam Hot water to 500 F (260 C) standard 750 F (400 C) optional Applications with optional pressure sensor Superheated steam to 500 F (260
More informationF-2700 SERIES INSERTION VORTEX FLOW METER
F-2700 SERIES INSERTION VORTEX FLOW METER APPLICATIONS Saturated steam Hot water to 500 F (260 C) standard 750 F (400 C) optional Applications with optional pressure sensor Superheated steam to 500 F (260
More informationVersaFlow Vortex 100 Vortex Flow Meter Technical Datasheet. Specification. The all-in-one solution. Highlights. Industries.
VersaFlow Vortex 100 Vortex Flow Meter Technical Datasheet 34-VF-03-05 September 3rd, 2008 Specification The all-in-one solution The VERSAFLOW is the only vortex flowmeter with integrated pressure and
More informationOPTISWIRL 4070 Technical Datasheet
OPTISWIRL 4070 Technical Datasheet Vortex flowmeter Integrated pressure and temperature compensation Temperature compensation for saturated steam included as standard All OPTISWIRL versions in 2-wire technology
More informationF-1500 SERIES INSERTION TURBINE FLOW METER
F-1500 SERIES INSERTION TURBINE FLOW METER APPLICATIONS Saturated steam Hot water to 450 F (232 C) standard 850 F (454 C) optional Applications with optional pressure sensor Superheated steam to 450 F
More informationMultivariable Vortex Flow Meter
Multivariable Vortex Flow Meter DVH Sensor Design w/o sealing Fully welded sensor Integrated temperature and pressure measurement (optional) Calculation of mass and density possible High temperature version
More informationSatellite photo of cloud vortices caused by a mountain (Courtesy of our friends at NASA) tekvorx Operation Showing Simplified Construction
Sensing the pulse of industry tekvorx TV01 Multivariable Vortex flow Sensors Vortex flow sensors derive their name from a natural phenomenon of fluid dynamics. When a gas or relatively low viscosity liquid
More informationF-2600 SERIES INLINE VORTEX FLOW METER
F-2600 SERIES ININE VORTEX FOW METER APPICATIONS Saturated steam Hot water to 500 F (260 C) standard 750 F (400 C) optional Applications with optional pressure sensor Superheated steam to 500 F (260 C)
More informationMetal tube flowmeters. Series SC250. Metal Tube Flow Meters. Series SC250. Variable area flowmeter for liquids, gases and steam
Metal tube flowmeters Variable area flowmeter for liquids, gases and steam Metallic or plastic tube with a robust construction Indication by means of magnetic coupling Scales calibrated in l/h, m 3 /h,
More informationF-2700 SERIES INSERTION VORTEX FLOW METER
F-2700 SERIES INSERTION VORTEX FLOW METER CALIBRATION Every ONICON flow meter is wet calibrated in a flow laboratory against standards that are directly traceable to N.I.S.T. A certificate of calibration
More informationSITRANS FX300 4/289. System Overview. Overview
Siemens G 2008 SITRNS F flowmeters Overview System Overview Version Single transmitter Dual transmitter Options Standard Pressure sensor Flange Pressure sensor and isola- Standard tion valve Sandwich vortex
More informationF-2500 SERIES VORTEX METER
F-500 SERIES VORTEX METER APPLICATIONS Saturated steam Hot water to F (0 C) Applications with optional pressure sensor Superheated steam to F (0 C) Compressed air Industrial gases CALIBRATION Each meter
More informationMetal tube variable area flowmeter for gases, liquids and steam
Metal tube variable area flowmeter for gases, liquids and steam Metallic or plastic tube with a robust construction Indication by means of magnetic coupling Scales calibrated in l/h, m 3 /h, kg/h, t/h,
More informationF-1500 SERIES INSERTION TURBINE FLOW METER FEATURES Belcher Road South, Largo, FL USA Tel +1 (727) Fax +1 (727)
F-1500 SERIES INSERTION TURBINE FLOW METER Insertion turbine flow meters are ideal for use in larger steam lines where downsizing the line size to improve flow measurement is not desirable. In these applications,
More informationVersaFlow Vortex 100 Vortex Flow Meter Specifications
VersaFlow Vortex 100 Vortex Flow Meter Specifications 34-VF-03-05 May 2011 The All-In-One Solution The VERSAFLOW is the only vortex flowmeter with integrated pressure and temperature compensation in 2-
More informationTurbine flowmeters Series TM
Turbine flowmeters Series TM Suitable for liquids Possibility of installation in all flow directions Special design for high pressure available Excellent relationship flow range / flowmeter size Low pressure
More informationINLINE Flow sensor for hazardous area II 1 G/D - II 2 D - II 3 GD - I M1
INLINE Flow sensor for hazardous area II G/D - II D - II GD - I M Type SE0 Ex can be combined with... Flow meter with NAMUR or NPN/PNP output signal Mounting, dismounting of electronics by a Quarter-Turn
More informationVortex Flow Meter Model DVH
Vortex Flow Meter measuring monitoring analysing DVH Measuring range: 3-8... 3057-280187 Nm³/h Accuracy: ± 0,7 % of reading (liquids) ± 1 % of reading (gases and steam) p max : 100 bar abs; t max : 400
More informationDVH. Vortex Flowmeter. Measuring range: Nm³/h. Accuracy: ± 0,7% of reading (liquids) ± 1% of reading (gases and steam) p max
Vortex Flowmeter measuring monitoring analysing DVH Measuring range: 3-8... 3057-280187 Nm³/h Accuracy: ± 0,7% of reading (liquids) ± 1% of reading (gases and steam) p max : 100 bar abs; t max : 400 C
More informationVIM20 Vortex Insertion Flowmeter
VIM20 Principle of Operation Vortex flowmeters measure flows of liquid, gas and steam by detecting the frequency at which vortices are alternately shed from a bluff body. According to proven laws of physics,
More informationFlow Measurement SITRANS F X SITRANS FX300 4/365
Siemens AG 200 Overview vortex flowmeters provide accurate volumetric and mass flow measurement of steam, gases and liquids as an all-in-one solution with integrated temperature and pressure compensation.
More informationSITRANS F X SITRANS FX300 3/355
Siemens AG 204 Flow Measurement Overview vortex flowmeters provide accurate volumetric and mass flow measurement of steam, gases and liquids as an all-in-one solution with integrated temperature and pressure
More informationO-100 Series GLASS TUBE TYPE ORIFLOMETER BEST COST EFFECTIVE FLOW MEASUREMENT EVEN FOR LARGE SIZE LINES GENERAL STANDARD SPECIFICATION MODEL CODE
BEST COST EFFECTIVE FLOW MESUREMENT EVEN FOR LRGE SIZE LINES O-0 Series GLSS TUBE TYPE ORIFLOMETER GENERL O-0 series ORIFLO METER is a flow meter consisting of a orifice plate and a GLSS TUBE type variable
More informationBFS-10-O G1/4: BFS-10-O G1/2: BFS-10-O G1: Contact rating: BFS-10-O G1/4
Flow Switches Index: B / 923-1838 BFS-10-N / BFS-10-O for monitoring liquids, with or without optical display Features set point continuously adjustable rugged, low hysteresis, any mounting position, high
More informationVortex Flowmeter Model DVE
Vortex Flowmeter Multi-Parameter measuring monitoring analysing DVE Measuring range Liquids: 5.2-157... 284-85371 m³/h Air: 89-1463... 26915-2467081 Nm 3 /h (20 C, 0 bar rel) Saturated steam: 81-938...
More informationMetal tube flowmeters Series M21 Variable area flowmeter for low flows of liquids, gases and steam
Metal tube flowmeters Series M21 Variable area flowmeter for low flows of liquids, gases and steam Metallic tube with a robust construction Indication by means of magnetic coupling Scales calibrated in
More informationORIFLO CONTENTS COST EFECTIVE FLOW MEASUREMENT FOR LIQUIDS AND GASES INTEGRATED ORIFICE FLOWMETERS GENERAL FEATURES MAIN APPLICATIONS
COST EFECTIVE FLOW MEASUREMENT FOR LIQUIDS AND GASES ORIFLO INTEGRATED ORIFICE FLOWMETERS GENERAL O series ORIFLO METER is a By-pass Orifice type flowmeter. Small sized variable flowmeter is installed
More informationSeries 8000 Vortex Flow Meter
VFM Series 8000 Vortex Flow Meter Operating Principle The operation of the VFM 8000 is based on the Karman Vortex Street. Vortices are formed as the fluid flows around the shedder body which are alternately
More informationUL350 ULTRASONIC FLOWMETER CLAMP-ON TYPE OUTLINE FEATURES MEASUREMENT PRINCIPLE
CLMP-ON TYPE UL350 ULTRSONIC FLOWMETER OUTLINE Our clamp-on type Ultrasonic Flowmeter UL350 has enabled applications to piping in various kinds by enhancing the permeation property of ultrasonic wave.
More informationSATRON VT Pressure Transmitter
SATRON VT pressure transmitter belongs to the series V-transmitters. SATRON VT is used for 0-1.4 kpa...0-100 MPa ranges. It is a 2-wire transmitter with HART standard communication. In pressure measuring
More informationVORTEX IN-LINE FLOW METERS
VORTEX IN-LINE FLOW METERS Principles of Operation Vortices are created when a fluid passes around a bluff body as shown below. Vortices are alternately shed on each side of the body, degrees out of phase
More informationGlass tube flowmeters Series 6000 Variable area flowmeter for liquids and gases
Glass tube flowmeters Series 6000 Variable area flowmeter for liquids and gases Easy installation Local indication by means of direct reading Low pressure drop Scales directly in l/h, m 3 /h, kg/h, l/min,
More informationOPTISWIRL 4200 Technical Datasheet
OPTISWIRL 4200 Technical Datasheet Vortex flowmeter Integrated pressure and temperature compensation Gross and net heat measurement for hot water and steam Stable measurements even under demanding process
More informationFlow switches Series AD/VH
Flow switches Series AD/VH Flow switch and indicator for liquids and gases Suitable for clear, opaque or turbid liquids (series AD & VH), and for gases (series AD) Flow switching by means of magnetic coupling,
More informationSTEEMCO-MAS Flowmeter for Steam
STEEMCO-MAS Flowmeter for Steam Typical Applications The STEEMCO-MAS flow meters measure the mass flow of superheated steam within the process industries, including chemical, petro-chemical, pharmaceutical
More informationPro-V Multivariable Flowmeter Model M24 In-line Vortex
Pro-V Multivariable Flowmeter Model M24 In-line Vortex Pro-V TM Advantage: VorTek Instruments Pro-V multivariable flowmeters utilize three primary sensing elements a vortex shedding velocity sensor, an
More informationVortex Flowmeter FV4000 (TRIO-WIRL V) Swirl Flowmeter FS4000 (TRIO-WIRL S) For flow rate and volume measurement of liquids, gases and steam
Vortex Flowmeter FV4000 (TRIO-WIRL V) Swirl Flowmeter FS4000 (TRIO-WIRL S) For flow rate and volume measurement of liquids, gases and steam Cost savings due to high accuracy Low investment cost through
More informationFlange connection type vortex flowmeter. Flange card type vortex flowmeter. Temperature-pressure compensation type. Insertion type vortex flowmeter
Exectromagetic flowmeter Tu bin f o m U a onic f o m Th o ing d vic Ro am LUGB-2 Flange connection type vortex flowmeter Flange card type vortex flowmeter Temperature-pressure compensation type Insertion
More informationVIM20 Vortex Insertion Flowmeter
Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without
More informationVortex Eggs Delta Flowmeter
Product Data Sheet PDS-FLM Vortex Eggs Delta Flowmeter Technical Specifications (Liquid, Gas & Air) Easy to read Free positioning EEPROM DESCRIPTION The unique sensor body and transmitter design makes
More informationFT-1000/FP-1000 FLOAT TYPE TANK GAUGES SIMPLE, RELIABLE, COST EFFECTIVE. The FT-1000 or FP-1000 series is a mechanical level gauge with a float.
SIMPLE, RELIABLE, COST EFFECTIVE FT-1000/FP-1000 FLOAT TYPE TANK GAUGES The FT-1000 or FP-1000 series is a mechanical level gauge with a float. The FT-1000 is a conventional float-tape level gauge with
More informationCATALOG KVFN. Vortex Flowmeter
CATALOG KVFN Vortex Flowmeter Main Features of KVFN Intelligent Vortex Flow Transducer Best of KVFN Intelligent Vortex Flow Transducer is piezocrystal built in bluff body to avoid fluid turbulence caused
More informationLow Profile Insertion Vortex
Low Profile Insertion Vortex Product Features The same insertion meter can measure Steam, Gases or Liquids. Standardize on an insertion bar that can measure line sizes 2 24 Heavy Duty & Maintenance Free
More informationHot Tap Insertion Vortex
Hot Tap Insertion Vortex Product Features The same insertion meter can measure Steam, Gases or Liquids. Standardize on an insertion bar that can measure line sizes 2 48 Heavy Duty & Maintenance Free Design
More informationType 2511/12. Type Type 2030 Cable plug. ASI cable plug. Dosing control. General technical data Orifice Type 6518
3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics Type 658 standard standard High flow-rate capacity Reduced power consumption Single or manifold mounting Standard-, EEx m and EEx i versions
More informationO-180/780 Series ORIFLO METER COST EFECTIVE FLOW MEASUREMENT FOR LIQUIDS AND GASES GENERAL FEATURES MAIN APPLICATIONS
COST EFECTIVE FLOW MEASUREMENT FOR LIQUIDS AND GASES O-18/78 Series ORIFLO METER GENERAL O Series ORIFLO METER is a By-pass Orifice type flowmeter. Small sized variable flowmeter is installed onto measuring
More informationVIM20 Vortex Insertion Flowmeter
Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without
More informationRelative pressure transmitter type 522 for shipbuilding
Relative pressure transmitter type 522 for shipbuilding Pressure range 0... 2.5 600 bar The compact type 522 pressure transmitter for shipbuilding is based upon the Huba Control developed thick film technology
More information3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics
/-, 5/- 5/-way Solenoid Valves for process pneumatics Type 658 stard High flow-rate capacity Reduced power consumption Single or manifold mounting stard Type 658/659 can be combined with... Stard-, EEx
More informationThermal Gas Mass Flowmeter Series TMF-300
Thermal Gas Mass Flowmeter Series TMF-300 Technical Superiorities a true mass flow meter which could measure the gas flow conveniently and accurately without compensation for temperature or pressure. Mass
More informationThe Multivariable Air Flow Meter
The Multivariable Air Flow Meter Model MVC10A/MVC10F OVERVIEW The Multivariable Mass Flow Meter model MVC10A/ MVC10F, a compact has all function necessary to measure nitrogen (N 2 ) gas, carbon dioxcide
More informationCATALOG KTLU. Vortex Flowmeter
CATALOG KTLU Vortex Flowmeter Technical Features No moving parts, high reliability and durability Convenient installation and maintenance Sensor not contact with the measured fluids directly, stable performance
More informationCATALOG KVFN. Vortex Flowmeter
CATALOG KVFN Vortex Flowmeter Main Features of KVFN Intelligent Vortex Flow Transducer Best of KVFN Intelligent Vortex Flow Transducer is piezocrystal built in bluff body to avoid fluid turbulence caused
More informationThe Multivariable Air Flow Meter
No. SS2-MVC200-0100 OVERVIEW The Multivariable Mass Flow Meter AIRcube, a compact has all function necessary to measure nitrogen (N 2 ) gas, carbon dioxcide (CO 2 ) gas and air. The model MVC10A/MVC10F
More informationCDT1000 Series QUICK FLOW. Digital Flowmeter for Air Conditioning Application OUTLINE FEATURES STANDARD SPECIFICATION
QUICK FLOW CDT1 Series Digital Flowmeter for Air Conditioning Application OUTLINE CDT1 is a new series of flowmeter which combines a multidigital indicator with a pitot tube. CDT1 detects the differential
More informationRIM20 Rotor Insertion Flowmeter
Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without
More informationThe readings you need, right where you need them. AX Series Vortex Meters
The readings you need, right where you need them. AX Series Vortex Meters Multivariable function from a single meter Vortex multivariable meters from Azbil North America employ three sensing elements in
More information3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics
/2-, 5/2-5/-way Solenoid Valves for process pneumatics Type 658 stard High flow-rate capacity Reduced power consumption Single or manifold mounting stard Type 658/659 can be combined with... Stard-, EEx
More informationPanaFlow MV80. In-line Multivariable Flowmeter for Mass, Temperature, and Pressure. GE Sensing. Applications. Key Benefits
Key Benefits Multivariable vortex flowmeter for measuring volumetric flow, temperature, pressure, density, and mass flow using a single meter Measures most gases, liquids and steam without the need to
More informationDifferential Pressure Gauges Cryo Gauge Model , Cu-alloy Model , Stainless Steel Series
Differential Pressure Gauges Cryo Gauge Model 712.15.160, Cu-alloy Model 732.15.160, Stainless Steel Series Mechanical Pressure Measurement WIKA Data Sheet PM 07.30 Applications Level measurement in closed
More informationSTEEMCO Flowmeter for Steam
STEEMCO Flowmeter for Steam Typical Applications The STEEMCO flow meters measure the flow of saturated and superheated steam within the process industries, including chemical, petro-chemical, pharmaceutical
More informationRosemount 8800D Series Vortex Flowmeter
Product Data Sheet HART AND FOUNDATION FIELDBUS PROTOCOLS Available with optional MultiVariable output and temperature compensated mass flow for saturated steam. Available in wafer, flanged, dual, reducer
More informationModel 8800C Vortex Flowmeter
Vortex Flowmeter Start Step 1: Mount the Flowmeter Step 2: Consider Housing Rotation Step 3: Set the Jumpers Step 4: Connect the Wiring and Power Up Step 5: Review Flowmeter Configuration Product Certifications
More informationSIGNET 7002 Vortex Flow Sensor ENGLISH
SIGNET 7002 Vortex Flow Sensor ENGLISH 3-7002.090 C-7/02 English SAFETY INSTRUCTIONS 1. Do not remove from pressurized lines. 2. Never install sensor without O-Rings. 3. Confirm chemical compatibility
More informationBGN. All Metal Variable Area Flow Meter. Technical Data Sheet
All Metal Variable Area Flow Meter BGN Technical Data Sheet Extremely robust through star guiding system instead of guiding rod Flow metering of liquids, gases and steam Available up to nominal size of
More informationFP-4000 Series FLOAT LEVEL SWITCH OUTLINE MAIN APPLICATIONS STANDARD SPECIFICATION
FOR MULTIPOINT LEVEL ALARM ETECTION BY ONE UNIT FP- Series FLOAT LEVEL SWITC OUTLINE The FP- series is a float level switch, which is installe through the tank nozzle on tanks an/or pits. Level alarm etection
More informationOrifice plate flowmeters Series PR By-pass flowmeter for liquids, gases and steam
Orifice plate flowmeters Series PR By-pass flowmeter for liquids, gases and steam By-pass flowmeter with orifice plate (compact system PRC and separate system PR) for big flow ranges Flow indication by
More informationKDM ARMORED FLOW METER & SWITCH
KDM ARMORED FLOW METER & SWITCH Flow Pressure Level Temperature measurement monitoring control S2 Short Installation Length SS, PTFE or Hastelloy Wetted Parts Analog Output Available 110 F to + 390 F Temperature
More informationGA 24 Heavy-duty variable area flowmeter
KROHNE 10/99 D 11 GA24 01 E GR Heavy-duty variable area flowmeter Variable area flowmeters Vortex flowmeters Flow controllers Electromagnetic flowmeters Ultrasonic flowmeters Mass flowmeters Level measuring
More informationVortex In Line Flow Meter
Vortex In Line Flow Meter Principles of Operation Vortices are created when a fluid passes around a bluff body as shown below. Vortices are alternately shed on each side of the body, 0 degrees out of phase
More informationWaterMAG. Electromagnetic Flowmeter for Water Applications. Model MCB10A OVERVIEW APPLICATIONS FEATURES. No. SS2-MCB
WaterMAG Electromagnetic Flowmeter for Water Applications OVERVIEW The WaterMAG is an electromagnetic flowmeter for water measurement applications based on field proven Azbil Corporation's technologies.
More informationLevel switches Series LC40 Float level switch for liquids
Level switches Series LC40 Float level switch for liquids Simple and robust construction Versatile and easily adaptable to the different control positions of the industrial processes Side or top of the
More information4-20mA, pulse with HART or pulse with RS485 are selectable. No moving parts, no abrasion, non-wearing parts inside, fully welded SS304
VORTEX FLOW METER Vortex Flowmeter Advantages: Integrated pressure and temperature compensation. 4-20mA, pulse with HART or pulse with RS485 are selectable. Wide temperature range up to highest temperature
More informationDetector (for water measurement applications)
WaterMAG Smart Electromagnetic Flowmeter Detector (for water measurement applications) Model MGW18 OVERVIEW The WaterMAG electromagnetic flowmeter detector is a high performance, highly reliable flowmeter
More informationThe readings you need, right where you need them. AX Series Vortex Meters
The readings you need, right where you need them. AX Series Vortex Meters Multivariable function from a single meter Principles of Operation Vortex multivariable meters from Azbil North America employ
More informationGeneral Specifications
General Specifications Model RAGG Rotameter This type of Rotameter is designed for measurement of liquids and gases. The conical glass metering tube has a free rotating float. This float is mounted in
More informationThe EPSILON is based on the principle of measuring velocity in the pipe line, therefore the flow measurement is volumetric.
Typical Applications EPSILON Flowmeter The EPSILON flow meters measure the flow of most liquids and gases within the process industries, including chemical, petro-chemical, pharmaceutical and the power