CDT1000 Series QUICK FLOW. Digital Flowmeter for Air Conditioning Application OUTLINE FEATURES STANDARD SPECIFICATION

Size: px
Start display at page:

Download "CDT1000 Series QUICK FLOW. Digital Flowmeter for Air Conditioning Application OUTLINE FEATURES STANDARD SPECIFICATION"

Transcription

1 QUICK FLOW CDT1 Series Digital Flowmeter for Air Conditioning Application OUTLINE CDT1 is a new series of flowmeter which combines a multidigital indicator with a pitot tube. CDT1 detects the differential pressure exerted by flow velocity in the pitot tube inserted in the pipe and outputs flow rate with digital indication. Applicable sizes range from 2mm to 4mm dia. The principal applications are for hot and cooling water lines for air conditioning in apartment and office buildings and other facilities. FEATURES Easy installation Installation simply by making a 5mm dia. hole and welding 2mm (/4") socket at measuring point of existing pipes. This is most convenient for renewal use when additional flow sensor is required on the line. Low pressure drop Wide measuring range Measuring range selectable depending on application Applicable for both horizontal and vertical pipes. Various indicator functions selectable from the following: Battery type, Current Output type (2wire 4 to 2mA), Alarm Output type, and LonWorks type Indicator parts are interchangeable. Easy to see because of large LCD display Compact size and lightweight Quick delivery STANDARD SPECIFICATION Measuring Fluid : Water, Cold water, Hot water Max. Pressure : 2MPa Max. Allowable Differential Pressure : 2kPa (Bias pressure) Temperature and Relative Humidity Fluid temperature : 1 to 7 o C Ambient Temp. : 1 to o C < 85%RH Storage Temp. : 2 to 6 o C < 85%RH (Without icing, without condensation) Process pipe size : 2mm(/4") to 4mm(18") Adaptation pipe : Carbon steel pipe for piping (JIS G 452) [1MPa class] Carbon steel pipe for pressure piping (JIS G 454 Sch4) [2MPa class] Note : If pipe other than above is required, special calibration may be necessary. Consult factory for details. Accuracy : 5% F.S. [std.] Accuracy is guaranteed for fluid temperature range 7 to 6 o C Measuring range : Flow rate from 1 to 1% of full scale Protection class : IP65 (JIS C 92) (Except for the air introduction port at the bottom of housing.) Mass : Approx. 2kg Indicator type function (All types with indicator) Type Battery type Current output type Alarm output type LonWorks Type Function Battery drive, Indication only 42mA DC (2wire) 2 points 42mA DC Applicable to LON communication network Indication function Flow rate indication 1/2 digits LCD (Height 18mm) : to 1999 (FFF appears in case of out of range) 11 segment bar graph Totalizer indication 71/2 digits LCD (Height 5mm): to Indication interval : 1s (Sampling.5 sec) Filter :,2,4,8,16,2s (Moving average) LCD back light : Continue 1s after operation (Except current output type) Material of Pitot tube parts : Refer to [OUTLINE DIMENSION] and [MATERIAL] Material of wetted parts of indicator Diaphragm : 16L SS Body : 16SS : Fluorine rubber (JIS Class4D) Drain hole sealing : Alumina ceramics Material of indicator body: Aluminium alloy Painting : Melamine resin painting (Indicator housing) Painting color Front : Wine red (Munsell 1RP/8) Rear : Light gray (Munsell N7.5) Process connection : R/4" (M) Installation posture : Front vertical installation TGF9762E May. 2K

2 CDT1 QUICK FLOW for Air Conditioning Application Digital Flowmeter Standard full scale range [SGP,STPG(4~4mm)pipe] Process pipe size Full scale range [L/min] Inside dia. (mm) mm inch Code MPa 2MPa 2 /4 7 1 (26) Refer to (4) following 2 11/ (4) table 4 11/ / Standard full scale range [2MPa version = 2~2mm] Process pipe size Full scale range [L/min] Inside dia. mm inch Code 1 2 (mm) 2 / / Standard full scale range [PVC lined pipe] Process pipe size Full scale range [L/min] Inside dia. mm inch Code (mm) / / / Note 1) The inside diameter of pipe size 2 to 2mm in 1MPa is based on threeway socket (JIS B 21). (It is possible to attach threeway socket as option.) 2) The inside diameter of pipe size 2 to 2mm in 2MPa is based on threeway socket (Sch.4). (Supplied by customer.) ) 4mm or more, the inside diameter of in 1MPa specification is based on Carbon steel tube for ordinary piping SGP (JIS G452), and the inside diameter of in 2MPa specification is based on Carbon steel pipes for pressure piping STPG (JIS G 454 Sch4). 4) Scale range of PVC lining is based on the inside diameter of the upper table. In the case of inside diameter other than the upper table, special calibration is required. Consult after checking L and D size of the figure in page 6. 2) Current output type Power supply :24V DC 1% Output :42mA DC (2wire) Max. load :6Ω Output accuracy :.5% F.S. at 2 o C Response :Less than 2 s (At filter setting ) ) Alarm output type Power Supply :24V DC 1% Power Consumption :Less than 25mA Alarm Output :Open Collector x 2 (Independent) Load :Less than V DC / 8mA Response :Less than 2 s (At Filter setting ) Alarm setting :Selectable (high / Low), Reset Span: Adjustable / Min. 1digit Output : 42mA DC Max. load :6Ω Output Accuracy :.5%F.S.at 2 o C 4) LonWorks type Applicable to Lon communication network. Communication with network devices by FTT1A Transceiver. Power Supply :24V AC 1% /, 6Hz Power Consumption :Less than 8mA Transmission LON Value :Flowrate and differential pressure (Convert the Indication value to LON value) Response :Less than 2 s (At Filter setting ) The communication of each device is in accordance with definite procedure related to its LON value. FTT1A can be connected by free topology and multi drop connection. Refer to [Function Profile] for detailed information Cable entry Type Cable entry L Cable entry R Battery type Current output type Alarm output type LonWorks type Acceptable cable outside diameter 8mm OPTION (Factory set) Totalizing indication Selection of totalizer function OPTION (Others) Refer to L CODE CODE : /TLZ : Yes : No Specification and function of each type 1) Battery type Battery Battery life :Alkali battery (LR6) x 2 pcs. :Approx. 2 years at 2 o C Auto power off mode selectable Low Battery monitor as standard 2 TOKYO KEISO CO., LTD. TGF9762E

3 l CDT1 QUICK FLOW for Air Conditioning Digital Flowmeter WIRING DIAGRAM [Current output type] [Alarm output type] Alarm output (1)/(2) : Open collector Load: Less than V DC/8mA (each) [LonWorks Type] 42mA DC24V Receiver ANA OUT DC24V Alarm output (1) Alarm output (2) 42mA Receiver Black Red White blue ~ AC24V NETB NETA Host device MATERIAL and OUTLINE DIMENSION CDT12 9 (.5) (184) (84) (1) l ADJ. Ao f f O U T 1 O U T 2 LRZ.kPa UNI T m / h cm / h o C (95) (9) (9) R/4 (Refer to approval drawing for the dimension I.) (21) Drain hole Cable entry L 21 CDT Cable entry R 5 (91.5) (84) 1 (14) Socket (CFSW) 9 /4 4.5 [OPTION] 8 SGP threeway socket (JIS B 21/CFTW) Rc/4 A A 1 O U T 1 O U T 2 UNI T m / h Air vent screw B 2d cm / h Aof f LRZ.kPa o C 72 Dimension of threeway socket Size d A B 2mm Rc/4 25mm Rc mm Rc11/ (199) 2 No. Part Description Material (41) (47) (127) (66.5) 4 Indicator body Aluminum alloy Isolation valve SCS 14 Valve Shaft SUS 16 NBR 5 Vent valve SUS 16 Cap nut SCS1 R/4 6 Fittings BC6 Pitot tube SUS 16 Socket SS 4*1 8 Threeway socket FCMB*1,2 *1 It is possible to attach standard material for socket (SS4 or FCMB) if requested, but material besides these materials shall be provided by customer when needed. *1,2 For the 2 MPa rating, the parts made of proper material such as S25C be selected and provided by customers considering pipe sch4. TGF9762E TOKYO KEISO CO., LTD.

4 1 o 1 1 o C cm/h o CDT1 QUICK FLOW for Air Conditioning Application Digital Flowmeter CONSTURUCTION CDT12 Vent valve (4pcs) Equalizing pressure valve with (P4) Bolt, Washer M5 x 2(4pcs) (S4) Vent plug (4pcs) (P8) (P8) Cap nut (S1.5) Pitot tube SCS14 Isolation valve Socket Fittings Screwing Welding Blind plug Piping Indicator Aoff LRZ kpa UNIT m/h cm/h Hexagon socket head cap screws M4 x 14(4pcs) C CDT14 Hexagon socket head cap screws M4 x 14(4pcs) Indicator Aoff LRZ kpa UNIT m/h cm/h [Option] Protection cover (For indicator protection) CODE : /HGC CAUTIONS ON INSTALLATION Avoid direct rays and equip with a protection cover or install in the place which a direct rainstorm does not splash. (If protection cover is used, it may be difficult to read the display.) Protection cover Equalizing pressure valve with (P4) (S4) Isolation valve Screwing Fittings Socket Blind plug Vent valve (2pcs) Vent plug (2pcs) Bolt, Washer M5 x 2(4pcs) (P8) (P8) Pitot tube (S1.5) Cap nut Welding Aoff UNIT m/h C Piping 4 TOKYO KEISO CO., LTD. TGF9762E

5 CDT1 QUICK FLOW for Air Conditioning Digital Flowmeter L CODE CDT1 L A / Description Installation 2 Horizontal type type 4 Perpendicular type 1 1MPa class Pressure rating 2 2MPa class 2 2mm 25 25mm 2 2mm 4 4mm mm 65 65mm 8 8mm 1 1mm Main pipe size mm 1 1mm 2 2mm 2 2mm mm mm 4 4mm 4 4mm 5 1 Full scale range Flow rate range 2 4 Battery type 5 Current output type 6 Alarm output type Indicator type 9 LonWorks type Application L For liquid Version A Version code /TLZ Totalization indicator With protection cover /HGC at display part Option* Threeway socket for /CFT piping (CFTW) /CFS Welding sockt (CFSW) /PL PVC lined pipe specification Blank Not provided Additional function /Z Provided Note Standard type Vertical type Carbon steel pipe for piping (JIS G 452) Carbon steel pipe for pressure piping (JIS G 454 Sch4) Nominal diameter for installation pipe Select for the code of Standard full scale range Battery drive 42mA DC (2wire) 2 points 42mA DC LonWorks available Attachment is possible in case of the quality of the material FCMB and 1MPa specification Available only for SS4 Inform us L and D dimension of figure in page 6. Not necessary if abovementioned code is available. Consult about the details of the pipe material or Pitottube length. *Note) Insert / between each code when the plural codes are selected. Code example 1: [In case optional code is not selected] Horizontal installation, Connection size mm, 1MPa class, Full scale flow rate code[1], Battery drive type Model code: CDT12114LA Code example 2: [In case all of the possible optional codes are selected] Vertical installation, Connection size 1mm, 1MPa class, Full scale flow rate code[5], Current output type, Totalization indicator, indication, With protection cover at display part, With welding socket Model code: CDT141155LA/TLZ/HGC/CFS Code example : [In case piping type specification] Horizontal installation, Connection size 8mm, Pipe material SUS4TPD, 1MPa class, Full scale flow rate code[2], Current output type, Totalization indicator, With welding socket Model code: CDT121825LA/TLZ/CFS/Z When the piping type is specified as seen in the above Code example, it will be additional function. Moreover, in case socket and threeway socket are prepared by customer, Pitot tube length may be changed by installation dimension. This will be an additional function. Accordingly the last letter of model code will be /Z in case of such special specification as not mentioned in the above mode code. TGF9762E TOKYO KEISO CO., LTD. 5

6 CDT1 QUICK FLOW for Air Conditioning Application Digtal Flowmeter INSTALLATION 1) Keep the upstream and downstream straight runs as required. 2) To install the flowmeters, Drill a hole of 5mm diameter into the pipe having more than or equal to 4mm diameter. Use the threeway socket for the pipe having less than or equal to 2 mm diameter. ) Select and drill the hole at right place so that the final fixed posture of indicator should be horizontal. 4) Weld the socket to the drilled hole. The centerline of the socket must be in line with the one of the pipe. 5) Screw the CDT1 into the welded socket to complete the installation. SUGGESTIONS The model CDT 12(4) 1 flowmeter is calibrated based on the inside diameter of JIS G452 SGP. For the model CDT 12(4) 2, calibrated JIS G454 Sch.4. Consult TOKYO KEISO if pipes are different from above. Specific calibration is required. Straight length for upstream and downstream is required for accurate measurement as shown in the following table, Size Upstream Downstream 2mm 1D 5D 4mm 5D D Note) D : Inside diameter of main pipe. Piping CDT12 CDT14 Threeway socket (2 to 2mm) Threeway socket Rc/4 Rc/4 Threeway socket Run the fluid fully in the pipe. Otherwise it could not be measured. Vent the air before measurement. See CDT1 Instruction Manual for further details. LINING AND OTHER PIPING In case of PVC lining piping, prepare bushing (25mm x 2mm) for the main pipe in more than 2mm and for branch tube in 25mm. Available for other piping. Inform of the types of piping and dimension of L and D of the following figure. Refer to the table for full scale flow rate. Straight piping ( 4mm) /4 /4 9 ØD 2mm L Bushing (R1 x Rc/4) ØD L Rc/4 Ø5 Ø5 Lining piping (PVC) Other piping 9 ORDERING INFORMATION Indicator 1. Model code 2. Quantity * Specification is subject to change without notice. Head Office : Shiba Toho Building, Shibakoen, Minatoku, Tokyo Tel : (KEY) ; Fax : overseas.sales@tokyokeiso.co.jp ; URL : 6 TGF9762E

CDT1000 series QUICK FLOW. Digital Flowmeter for Air Conditioning Application OUTLINE FEATURES STANDARD SPECIFICATION

CDT1000 series QUICK FLOW. Digital Flowmeter for Air Conditioning Application OUTLINE FEATURES STANDARD SPECIFICATION QUICK FLOW CDT1 series Digital Flowmeter for ir Conditioning pplication OUTLINE CDT1 is a new series of flowmeter which combines a multidigital indicator with a pitot tube. CDT1 detects the differential

More information

HDT1000 series ORIFLO METER. Multi-function Digital Flowmeter OUTLINE STANDARD SPECIFICATION FEATURES MAIN APPLICATIONS INDICATOR SPECIFICATION

HDT1000 series ORIFLO METER. Multi-function Digital Flowmeter OUTLINE STANDARD SPECIFICATION FEATURES MAIN APPLICATIONS INDICATOR SPECIFICATION ORIFO METER HDT series Multifunction Digital Flowmeter OUTINE HDT is a new series Oriflo meter combining orifice plate with multidigital indicator. HDT detects differential pressure exerted by flow velocity

More information

STANDARD SPECIFICATIONS

STANDARD SPECIFICATIONS CFW1000 C C C C CFW1000 CFW1 Description Installation 2 Horizontal type 4 Vertical Indicator 1 20 C water calibration 2 7 C and 60 C water, double scale 1 Scale range 1 See right table Scale range 2 Scale

More information

STK2000/7400 Series. Flapper-type Flowmeter OUTLINE FEATURES PRINCIPLE STANDARD SPECIFICATIONS. Specifications of the metal measuring tube

STK2000/7400 Series. Flapper-type Flowmeter OUTLINE FEATURES PRINCIPLE STANDARD SPECIFICATIONS. Specifications of the metal measuring tube STK2000/7400 Series Flapper-type Flowmeter OUTLINE The STK2000 and STK7400 are high-accuracy, high-performance, flapper-type flowmeters. The STK2000 is a local indication type, and the STK7400 is a local

More information

O-1000 Series ORIFLOMETER MOST COST EFFECTIVE FLOW MEASUREMENT GENERAL STANDARD SPECIFICATIONS TYPES AND FUNCITON

O-1000 Series ORIFLOMETER MOST COST EFFECTIVE FLOW MEASUREMENT GENERAL STANDARD SPECIFICATIONS TYPES AND FUNCITON MOST COST EFFECTIVE FLOW MEASUREMENT O-1000 Series ORIFLOMETER GENERAL O-1000 series ORIFLO METER is a flow meter consisting of an orifice plate and a metal tube variable area flow meter. Since the flow

More information

SRT1000 Series THERMAL FLOWMETER

SRT1000 Series THERMAL FLOWMETER High-performance gas flowmeter SRT1000 Series THERMAL FLOWMETER OUTLINE Based on the long experienced know-how on the TOKYO KEISO's thermal flowmeters, SRT1000 series has enhanced its performance such

More information

R-101-E GLASS TUBE FLOWMETER BEST COST PERFORMANCE GENERAL STANDARD SPECIFICTION. Max. fluid press. MPa Meter size.

R-101-E GLASS TUBE FLOWMETER BEST COST PERFORMANCE GENERAL STANDARD SPECIFICTION. Max. fluid press. MPa Meter size. BEST COST PERFORMANCE R-1-E GLASS TUBE FLOWMETER GENERAL R-1-E is a glass tube type variable area flowmeter. The flow rate is indicated by the position of float and the graduation engraved on the glass

More information

O-180/780 Series ORIFLO METER COST EFECTIVE FLOW MEASUREMENT FOR LIQUIDS AND GASES GENERAL FEATURES MAIN APPLICATIONS

O-180/780 Series ORIFLO METER COST EFECTIVE FLOW MEASUREMENT FOR LIQUIDS AND GASES GENERAL FEATURES MAIN APPLICATIONS COST EFECTIVE FLOW MEASUREMENT FOR LIQUIDS AND GASES O-18/78 Series ORIFLO METER GENERAL O Series ORIFLO METER is a By-pass Orifice type flowmeter. Small sized variable flowmeter is installed onto measuring

More information

ORIFLO CONTENTS COST EFECTIVE FLOW MEASUREMENT FOR LIQUIDS AND GASES INTEGRATED ORIFICE FLOWMETERS GENERAL FEATURES MAIN APPLICATIONS

ORIFLO CONTENTS COST EFECTIVE FLOW MEASUREMENT FOR LIQUIDS AND GASES INTEGRATED ORIFICE FLOWMETERS GENERAL FEATURES MAIN APPLICATIONS COST EFECTIVE FLOW MEASUREMENT FOR LIQUIDS AND GASES ORIFLO INTEGRATED ORIFICE FLOWMETERS GENERAL O series ORIFLO METER is a By-pass Orifice type flowmeter. Small sized variable flowmeter is installed

More information

UL6300 SONICMAX. Ultrasonic Clamp-on Flowmeter OUTLINE FEATURES STANDARD SPECIFICATION. Common specification

UL6300 SONICMAX. Ultrasonic Clamp-on Flowmeter OUTLINE FEATURES STANDARD SPECIFICATION. Common specification SONICMAX UL63 Ultrasonic Clamp-on Flowmeter OUTLINE SONICMAX UL63 is the ultrasonic flowmeter of the time flight system which combined the highly efficient converter (UFC3) with the clamp-on sensor (UFS6).

More information

EGM5300C MAGMAX. Compact Electromagnetic Flowmeter GENERAL FEATURES STANDARD SPECIFICATION. General Specification

EGM5300C MAGMAX. Compact Electromagnetic Flowmeter GENERAL FEATURES STANDARD SPECIFICATION. General Specification MAGMAX EGM53C Compact Electromagnetic Flowmeter GENERAL MAGMAX EGM53C is a combination of EGS5 primary head with Ceramic measuring tube and high performance converter EGC3. EGM53C with high durability

More information

O-180/780 Series ORIFLO METER COST EFECTIVE FLOW MEASUREMENT FOR LIQUIDS AND GASES GENERAL FEATURES MAIN APPLICATIONS

O-180/780 Series ORIFLO METER COST EFECTIVE FLOW MEASUREMENT FOR LIQUIDS AND GASES GENERAL FEATURES MAIN APPLICATIONS COST EFECTIVE FLOW MEASUREMENT FOR LIQUIDS AND GASES O-18/78 Series ORIFLO METER GENERAL O Series ORIFLO METER is a By-pass Orifice type flowmeter. Small sized variable flowmeter is installed on measuring

More information

EGM1100C MAGMAX. Compact Electromagnetic Flowmeter GENERAL FEATURES STANDARD SPECIFICATION. General Specification

EGM1100C MAGMAX. Compact Electromagnetic Flowmeter GENERAL FEATURES STANDARD SPECIFICATION. General Specification EGMC Compact Electromagnetic Flowmeter GENERA MAGMAX EGMC is the compact type electromagnetic flowmeter with a converter EGC mounted integrally on a primary head EGS lined with fluorocarbon resin PFA.

More information

O-100 Series GLASS TUBE TYPE ORIFLOMETER BEST COST EFFECTIVE FLOW MEASUREMENT EVEN FOR LARGE SIZE LINES GENERAL STANDARD SPECIFICATION MODEL CODE

O-100 Series GLASS TUBE TYPE ORIFLOMETER BEST COST EFFECTIVE FLOW MEASUREMENT EVEN FOR LARGE SIZE LINES GENERAL STANDARD SPECIFICATION MODEL CODE BEST COST EFFECTIVE FLOW MESUREMENT EVEN FOR LRGE SIZE LINES O-0 Series GLSS TUBE TYPE ORIFLOMETER GENERL O-0 series ORIFLO METER is a flow meter consisting of a orifice plate and a GLSS TUBE type variable

More information

UL350 ULTRASONIC FLOWMETER CLAMP-ON TYPE OUTLINE FEATURES MEASUREMENT PRINCIPLE

UL350 ULTRASONIC FLOWMETER CLAMP-ON TYPE OUTLINE FEATURES MEASUREMENT PRINCIPLE CLMP-ON TYPE UL350 ULTRSONIC FLOWMETER OUTLINE Our clamp-on type Ultrasonic Flowmeter UL350 has enabled applications to piping in various kinds by enhancing the permeation property of ultrasonic wave.

More information

The Multivariable Air Flow Meter

The Multivariable Air Flow Meter The Multivariable Air Flow Meter Model MVC10A/MVC10F OVERVIEW The Multivariable Mass Flow Meter model MVC10A/ MVC10F, a compact has all function necessary to measure nitrogen (N 2 ) gas, carbon dioxcide

More information

UL6300 SONICMAX. Ultrasonic Clamp-on Flowmeter OUTLINE FEATURES MEASURING PRINCIPLE

UL6300 SONICMAX. Ultrasonic Clamp-on Flowmeter OUTLINE FEATURES MEASURING PRINCIPLE SONICMAX UL63 Ultrasonic Clamp-on Flowmeter OUTLINE SONICMAX UL63 is the ultrasonic flowmeter of the time flight system which combined the highly efficient converter (UFC3) with the clamp-on sensor (UFS6).

More information

The Multivariable Air Flow Meter

The Multivariable Air Flow Meter No. SS2-MVC200-0100 OVERVIEW The Multivariable Mass Flow Meter AIRcube, a compact has all function necessary to measure nitrogen (N 2 ) gas, carbon dioxcide (CO 2 ) gas and air. The model MVC10A/MVC10F

More information

WaterMAG. Electromagnetic Flowmeter for Water Applications. Model MCB10A OVERVIEW APPLICATIONS FEATURES. No. SS2-MCB

WaterMAG. Electromagnetic Flowmeter for Water Applications. Model MCB10A OVERVIEW APPLICATIONS FEATURES. No. SS2-MCB WaterMAG Electromagnetic Flowmeter for Water Applications OVERVIEW The WaterMAG is an electromagnetic flowmeter for water measurement applications based on field proven Azbil Corporation's technologies.

More information

AM-2000 series HYBRID FLOWMETER

AM-2000 series HYBRID FLOWMETER AM- series HYBRID FLOWMETER OUTLINE AM- series is a new all metal type flowmeter. AM- series integrates formerly separate functional devices to facilitate mounting in restricted spaces. Suitable for liquid,

More information

General Specifications

General Specifications General Specifications Model DT450G Dust Monitor GENERAL Powder is used in many industries including ceramics,cement, chemicals, pharmaceutical and food. In their processes, powder is collected in order

More information

VFM4070C SWIRLMAX. Vortex Flowmeter OUTLINE FEATURES OPERATING PRINCIPLE STANDARED SPECIFICATION. General Specification. Sensor Specification

VFM4070C SWIRLMAX. Vortex Flowmeter OUTLINE FEATURES OPERATING PRINCIPLE STANDARED SPECIFICATION. General Specification. Sensor Specification SWIRMAX VFM4070C Vortex Flowmeter OUTINE SWIRMAX is 2-wire, all-in-one type vortex flowmeter with both temperature and pressure sensors integrally mounted into the housing. It allows temperature and pressure

More information

FT-1000/FP-1000 FLOAT TYPE TANK GAUGES SIMPLE, RELIABLE, COST EFFECTIVE. The FT-1000 or FP-1000 series is a mechanical level gauge with a float.

FT-1000/FP-1000 FLOAT TYPE TANK GAUGES SIMPLE, RELIABLE, COST EFFECTIVE. The FT-1000 or FP-1000 series is a mechanical level gauge with a float. SIMPLE, RELIABLE, COST EFFECTIVE FT-1000/FP-1000 FLOAT TYPE TANK GAUGES The FT-1000 or FP-1000 series is a mechanical level gauge with a float. The FT-1000 is a conventional float-tape level gauge with

More information

FLOW METER ULTRASONIC-VOLTEX FLOW METER ASUSV SERIES IMPELLER FLOW METER ASIP80 SERIES IMPELLER FLOW METER ASSPX SERIES

FLOW METER ULTRASONIC-VOLTEX FLOW METER ASUSV SERIES IMPELLER FLOW METER ASIP80 SERIES IMPELLER FLOW METER ASSPX SERIES FLOW METER P.193 P.195 P.196 P.197 P.198 P.198 P.198 P.199 P.199 P.200 P.200 P.200 P.200 ULTRASONIC-VOLTEX FLOW METER ASUSV SERIES IMPELLER FLOW METER ASIP80 SERIES IMPELLER FLOW METER ASSPX SERIES INSERTION

More information

MASSMAX 1000 Series Straight twin tube Coriolis Mass Flowmeter

MASSMAX 1000 Series Straight twin tube Coriolis Mass Flowmeter MASSMAX Series Straight twin tube Coriolis Mass Flowmeter OUTLINE MASSMAX series is the coriolis mass flowmeters developed on the theme of the straight tube model which is excellent in cost performance.

More information

UCM -04A/06A RoHS compliance

UCM -04A/06A RoHS compliance Converter integrate type ultrasonic flowmeter -4A/6A RoHS compliance ULTRASONIC COMPACT METER LE The -4A/6A is the converter integrate type ultrasonic flowmeter for small flow that offers precise an stable

More information

AM9000 Series GENERAL FEATURES METAL TUBE VARIABLE AREA FLOWMETER

AM9000 Series GENERAL FEATURES METAL TUBE VARIABLE AREA FLOWMETER METAL TUBE VARIABLE AREA FLOWMETER AM9000 Series GENERAL The AM9000 series metal tube variable area flowmeters have the unified face-to-face dimension mm. Having developed the current well-accepted AM7000

More information

2-Color Display High-Precision Digital Pressure Switch

2-Color Display High-Precision Digital Pressure Switch 2-Color Display High-Precision Digital Pressure Switch Series ZSE3/ISE3 2-color digital display allows you to choose the setting according to your application requirements. 4 different display settings

More information

유량계전문제조업체. Electro Magnetic FLOWMETER

유량계전문제조업체. Electro Magnetic FLOWMETER 유량계전문제조업체 w w w. f c k o r e a i n s. c o m Electro Magnetic FLOWMETER ELECTRO-MAGNETIC FLOW METER Contents Principle of Operation 04 Grounding Method 05~07 Piping Installation 08 CN-400 CNT-2 Flanged

More information

OBE (On-Board Electronics) Type Direct Operated Linear Servo Valves (Size: 01 & 03) LSVG-01-EH-*-**-**-10, LSVG-03EH-*-**-**-10/1006

OBE (On-Board Electronics) Type Direct Operated Linear Servo Valves (Size: 01 & 03) LSVG-01-EH-*-**-**-10, LSVG-03EH-*-**-**-10/1006 NO. 10 01E September 1, 2010 Public Relations Group Products Publicity Section Sales Administration Department Hamamatsucho Seiwa Bdg., 4-8, Shibadaimon 1-chome, Minato-ku, Tokyo 105-0012, Japan Tel: +81-3-3432-2113

More information

Series ZSE30/ISE30. High Precision, 2-color Display Digital Pressure Switch. With One-touch fittings are newly introduced. PSE

Series ZSE30/ISE30. High Precision, 2-color Display Digital Pressure Switch. With One-touch fittings are newly introduced. PSE High Precision, 2-color Display Digital Pressure Switch Series SE30/ISE30 SE ISE PSE I SE3 PS I SE 1 2 SP ISA2 IS SM PF2 IF Data With One-touch fittings are newly introduced. Straight type Elbow type 16-2-1

More information

Digital display Pressure range ON/OFF output Linear output Model

Digital display Pressure range ON/OFF output Linear output Model Slim Digital Pressure Sensor E8CB/ CSM_E8CB DS_E 1 with Built-in Microcomputer and Digital Display Withstands a of 9 kpa and highly reliable. Incorporates a two-turn adjuster ensuring easy setting. Be

More information

Thermal Gas Mass Flowmeter Series TMF-300

Thermal Gas Mass Flowmeter Series TMF-300 Thermal Gas Mass Flowmeter Series TMF-300 Technical Superiorities a true mass flow meter which could measure the gas flow conveniently and accurately without compensation for temperature or pressure. Mass

More information

Electric Top-Guided Single-Seated Control Valves

Electric Top-Guided Single-Seated Control Valves No. SS2-AGV200-0300 CV3000 Alphaplus series Electric Top-Guided Single-Seated Control Valves Model AGVB / AGVM OVERVIEW The CV3000 Alphaplus range of top-guided single-seat control valves features a compact

More information

NO ENTRY No entry for Models 605, 610 or 620. Enter maximum flow rate for Model 600 with external flow sensor

NO ENTRY No entry for Models 605, 610 or 620. Enter maximum flow rate for Model 600 with external flow sensor Precise programmable control of liquid flow rate from 0.5 5, 1 10 or 2 20 L/min Useable to 60 C, 60 psi Integrated axial-flow turbine flowmeter Fast, responsive PID controller rotates vane to maintain

More information

Micro-differential Pressure High-precision Digital Pressure Sensor For Gas DP-M SERIES

Micro-differential Pressure High-precision Digital Pressure Sensor For Gas DP-M SERIES MODE 729 Micro-differential Pressure High-precision Digital Pressure Sensor For Gas SERIES Related Information General terms and conditions... F-3 Glossary of terms... P.1563~ guide... P.699~ General precautions...

More information

HN B G1/US B G2/US B G3

HN B G1/US B G2/US B G3 HN B G/US B G/US B G Compact direct acting, port solenoid valve air, water,, low vacuum (. x 0 Pa (abs)) CONTENTS Safety precautions port solenoid valve HNB NC (normally closed) type USB NC (normally closed)

More information

Paddle-wheel flow controller for On/Off control

Paddle-wheel flow controller for On/Off control Paddle-wheel flow controller for On/Off control Type 803 can be combined with... Indication, monitoring, transmitting and On/Off control in one device Programmable s (transistor or relay) Automatic-calibration:

More information

INSTRUCTION MANUAL VISCOTESTER VT-05 / VT-06 PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION

INSTRUCTION MANUAL VISCOTESTER VT-05 / VT-06 PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION INSTRUCTION MANUAL VISCOTESTER VT-05 / VT-06 PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION 3, Hagavish st. Israel 58817 Tel: 972 3 5595252, Fax: 972 3 5594529 mrc@mrclab.com MRC.4.17 Organization

More information

Micro-differential Pressure High-precision Digital Pressure Sensor For Gas DP-M SERIES

Micro-differential Pressure High-precision Digital Pressure Sensor For Gas DP-M SERIES MODE 751 Micro-differential Pressure High-precision Digital Pressure Sensor For Gas SERIES Related Information General terms and conditions... F-7 Glossary of terms... P.1469 ~ Sensor selection guide...

More information

Electro-Pneumatic Regulator/Electronic Vacuum Regulator

Electro-Pneumatic Regulator/Electronic Vacuum Regulator Electro-Pneumatic Regulator/Electronic Vacuum Regulator Series Stepless control of air pressure proportional to an electrical signal // series are compatible with various input specifications, including

More information

Internet For latest information, PDF catalogs and operation manuals

Internet  For latest information, PDF catalogs and operation manuals EcoRich Features Achieves a % or greater energy saving (in the pressure retained mode, comparison with Daikin products) Drastic energy savings are realized by reducing the motor rotation speed in pressure

More information

Insertion magnetic inductive flowmeter

Insertion magnetic inductive flowmeter Insertion magnetic inductive flowmeter Sensor without moving parts Flowmeter with On/Off control Application related calibration by Teach-In function Clean in place (CIP) FDA-compliant materials Type 8041

More information

Smart Pressure Transmitter

Smart Pressure Transmitter DOC. NO.: C3500L-E16A Smart Pressure Transmitter with Diaphragm Seal MODEL APT3500L 298-29, GONDAN-RO, GUNPO-SI, GYEONGGI-DO, KOREA 15809 Tel : +82-31-3-6100 Fax : +82-31-29-7200 E-mail: autrol@duon.co.kr,

More information

Series 10-ZSE40A(F)/10-ISE40A

Series 10-ZSE40A(F)/10-ISE40A Series 10-ZSEA(F)/10-ISEA RoHS 2-Color Display High Precision Digital Pressure Switch How to Order For positive pressure Clean series For vacuum/ compound pressure 01 N01 W1 10 Rated pressure range ISEA

More information

Pressure measurements can easily be taken any time, anywhere. POWER LIGHT

Pressure measurements can easily be taken any time, anywhere. POWER LIGHT Compact Manometer Pressure measurements can easily be taken any time, anywhere. RoHS Compact and lightweight Portable type with a lightweight of only about 00 g (unit 50 g, battery 50 g) can also be held

More information

Differential Pressure Sensor

Differential Pressure Sensor Differential Pressure Sensor "Cube" Type Differential Pressure Sensor with LED Display Offers High Precision Sensing 31 (1.) x 3 (1.18) x 3 (1.18) mm compact-cube style saves mounting space Easy-to-read

More information

4 Note 1) Value for communications type. (PROFIBUS DP)

4 Note 1) Value for communications type. (PROFIBUS DP) Electro-Pneumatic Regulator/Electronic Vacuum Regulator Series Stepless control of air pressure proportional to an electrical signal Series // are compatible with various input specifications, including

More information

Paddle-wheel flow controller for On/Off control

Paddle-wheel flow controller for On/Off control Paddle-wheel flow controller for On/Off control Type 8032 can be combined with... Indication, monitoring, transmitting and On/Off control in one device Programmable outputs (transistor or relay) Automatic-calibration:

More information

General Specifications

General Specifications eneral Specifications Model TB Surface Scattering Light Meter S 12E04A02-01E eneral There have been increasing demands for both industrial use and portable water of good quality because of rapid industrial

More information

To avoid injury, death of personnel ordamage to instrument, the operator must refer to an explanation in the User smanual.

To avoid injury, death of personnel ordamage to instrument, the operator must refer to an explanation in the User smanual. www.malema.com VF-3000 Flow Sensor M-1500 INSTRUCTION MANUAL Non-invasive Inline 1. NOTICE 1) This manual should be passed on to the installer and the operator of this product. 2) Please read this manual

More information

FP-4000 Series FLOAT LEVEL SWITCH OUTLINE MAIN APPLICATIONS STANDARD SPECIFICATION

FP-4000 Series FLOAT LEVEL SWITCH OUTLINE MAIN APPLICATIONS STANDARD SPECIFICATION FOR MULTIPOINT LEVEL ALARM ETECTION BY ONE UNIT FP- Series FLOAT LEVEL SWITC OUTLINE The FP- series is a float level switch, which is installe through the tank nozzle on tanks an/or pits. Level alarm etection

More information

Pressure Transmitter

Pressure Transmitter FCO318 Differential Pressure Transmitter Accuracy 0.25% of reading Ultra low pressure measurement Wide span adjustment 2-wire ma, 3-wire or 4-wire voltage output Two configurable relays and bi-colour LED

More information

A superb way to save energy when using compressed air or nitrogen. Air Flow Meter CP-PC-1474E

A superb way to save energy when using compressed air or nitrogen. Air Flow Meter CP-PC-1474E CP-PC-4E superb way to save energy when using compressed air or nitrogen. ir Flow Meter www.azbil.com Please read the "Terms and Conditions" from the following URL before ordering or use: http://www.azbil.com/products/bi/order.html

More information

ATi Max Series. Pressure Independent Control Valves 2 Way 2-1/2-6

ATi Max Series. Pressure Independent Control Valves 2 Way 2-1/2-6 The Auto Touch Independent Max (ATiMX) valve brings pressure independent control technology to valves up to 6 and flow rates up to 468 GPM. It is a state-of-the-art control valve combining a high quality/

More information

2-Color Display Digital Flow Switch

2-Color Display Digital Flow Switch -Color Display Digital Flow Switch Series Flow rate range:, 5, 5, l/min. Minimum unit setting:. l/min. (. l/min when the flow rate range is 5, 5, l/min.) Repeatability: ±%F.S. or less Grease-free Flow

More information

Model Pressure range ON/OFF output Linear output

Model Pressure range ON/OFF output Linear output Digital Sensor Sensor with Easy-to-Read LED Display status can be checked at a glance from the red digital pressure value and analog bar displays. Measurement pressure is averaged by the chattering prevention

More information

1 Pneumatics. Transmitters VR4151 VR4152 VR1210 VR1220 VR1210F VR1220F VR1211F VR VR3200 VR3201 VR3100 VR3110

1 Pneumatics. Transmitters VR4151 VR4152 VR1210 VR1220 VR1210F VR1220F VR1211F VR VR3200 VR3201 VR3100 VR3110 Best 1 Pneumatics Transmitters Relay valve P. 1900 Side piping: 30 x 53 x 91 Bottom piping: 30 x 8 x 91 VR151 VR152 Effective area (mm 2 ) Number of ports Function 7 5 Metal Spool Shuttle valve P. 1902

More information

Smart Electromagnetic Flowmeter Detector for Sanitary use

Smart Electromagnetic Flowmeter Detector for Sanitary use MagneW3000 PLUS Smart Electromagnetic Flowmeter Detector for Sanitary use Model MGS28U OVERVIEW The MagneW3000 PLUS Smart Electromagnetic Flowmeter for Sanitary use is a high-performance and highly-reliable

More information

2-colour display. Digital Pressure Switch. Stainless diaphragm Oil-free (Single-layer diaphragm structure) IP65 compliant

2-colour display. Digital Pressure Switch. Stainless diaphragm Oil-free (Single-layer diaphragm structure) IP65 compliant -Colour Display Digital Pressure Switch Stainless diaphragm Oil-free (Single-layer diaphragm structure) Sensor parts: Stainless steel 6 Fitting parts: Stainless steel 4 The sensor and fitting parts can

More information

Electro-Pneumatic Regulator Electronic Vacuum Regulator

Electro-Pneumatic Regulator Electronic Vacuum Regulator Electro-Pneumatic Regulator Electronic Vacuum Regulator New Stepless control of air pressure proportional to an electrical signal Added Fieldbus compliant specifications to Series ITV//! Reduced wiring

More information

HG5 Series. Metal Tube Rotameter CATALOG MAIN FEATURES TECHNICAL PARAMETERS

HG5 Series. Metal Tube Rotameter CATALOG MAIN FEATURES TECHNICAL PARAMETERS H5 Series Metal Tube Rotameter H5 series metal tube rotameter (also called variable area flow meter) is a kind of measuring meter which the flow rate is changing along with the area and is widely used

More information

1000 Series MASSMAX. Coriolis Mass Flowmeter Straight Twin Tube OUTLINE FEATURES STANDARD SPECIFICATIONS. Fluid Specifications

1000 Series MASSMAX. Coriolis Mass Flowmeter Straight Twin Tube OUTLINE FEATURES STANDARD SPECIFICATIONS. Fluid Specifications MSSMX Series Coriolis Mass Flowmeter Straight Twin Tube OUTLINE MSSMX series is the coriolis mass flowmeters developed on the theme of the straight tube model which is excellent in cost performance. The

More information

TL RELAYS. TYPICAL APPLICATIONS Head lamp, Fog lamp, Fan motor, etc. ORDERING INFORMATION TYPES. High Load Relay for Smart Junction Box ACTL.

TL RELAYS. TYPICAL APPLICATIONS Head lamp, Fog lamp, Fan motor, etc. ORDERING INFORMATION TYPES. High Load Relay for Smart Junction Box ACTL. High Load Relay for Smart Junction Box TL RELAYS High heat-resistant type: Sealed Pin in Paste compliant type: Flux tight New 14.4.7 11.433 1.3 FEATURES Large capacity switching

More information

Series ZSE30/ISE30. High Precision, 2-color Display Digital Pressure Switch 25 M ISE30 01 ZSE M. How to Order. For positive pressure

Series ZSE30/ISE30. High Precision, 2-color Display Digital Pressure Switch 25 M ISE30 01 ZSE M. How to Order. For positive pressure High Precision, Series SE30/ISE30 How Order Option 1 Without lead wire Lead wire with connecr (Lead wire length: 2 m) L For positive pressure For vacuum/low pressure ISE30 01 SE30 01 25 M 25 M 01 R 1/8

More information

MIDDLE LOAD RELAY FOR SMART J/B

MIDDLE LOAD RELAY FOR SMART J/B MIDDLE LOAD RELAY FOR SMART J/B CN-M RELAYS (ACNM) New Compliance with RoHS Directive FEATURES. Best space savings in its class.. Compact and high-capacity A load switching.. Full line up (High heat-resistant

More information

TC RELAYS. TYPICAL APPLICATIONS Head lamp, Fog lamp, Fan motor, Defogger, Seat heater, etc. ORDERING INFORMATION. High Load Relay for Smart J/B ACTC

TC RELAYS. TYPICAL APPLICATIONS Head lamp, Fog lamp, Fan motor, Defogger, Seat heater, etc. ORDERING INFORMATION. High Load Relay for Smart J/B ACTC High Load Relay for Smart J/B TC RELAYS /High heat-resistant type: Sealed Pin in Paste compliant type: Flux tight FEATURES Large capacity switching despite small size. Can replace

More information

INSERTION flowmeter with paddle wheel, ELEMENT design

INSERTION flowmeter with paddle wheel, ELEMENT design INSERTION flowmeter with paddle wheel, design Up to PN, size of measurement pipes: DN to DN400 Configurable outputs: one or two transistor output(s) and single or dual 4... ma analog output(s) Removable

More information

Miniature Regulator Series ARJ310

Miniature Regulator Series ARJ310 Miniature Regulator Series 30 Compact and lightweight (Main body 65 g) 8.3 Improved flow characteristics 0. 0. 0 00 00 300 400 500 Allows smaller mounting pitch 8.8mm 0-M5 30-0 Inlet pressure: MPa Accommodates

More information

Temperature Indicating Controller

Temperature Indicating Controller \ KF Series Temperature Indicating Controller Model KFT OVERVIEW The KF Series instruments are field-installed type of pneumatic indicating controllers which are used to measure and control the various

More information

2-Color Display High-Precision Digital Pressure Switch

2-Color Display High-Precision Digital Pressure Switch 2-Color Display High-Precision Digital Pressure Switch Settings can be copied to up to 1 slave sensors at once. The settings of the master sensor can be copied to the slave sensors. Reduced setting efforts

More information

COMPACT SIZE HIGH PRECISION POWER ON-DELAY TIMERS. 10 position

COMPACT SIZE HIGH PRECISION POWER ON-DELAY TIMERS. 10 position PMH Timers COMPACT SIZE HIGH PRECISION POWER ON-DELAY TIMERS PMH RoHS compliance Features Using a dedicated IC, the operation time variance is.5%. Using the slide, time range switching is easy. Meover,

More information

SS Concentration Analyzer

SS Concentration Analyzer SS Concentration nalyzer Model : SSD-6 (for Low Concentration Measurement) SSD-6 (for Medium Concentration Measurement) n SS concentration analyzer is an optically based measurement instrument for continuously

More information

Pressure Drop (Reference (typical)) 0.19 kpa 0.48 kpa Operating Temperature

Pressure Drop (Reference (typical)) 0.19 kpa 0.48 kpa Operating Temperature MEMS Mass Flow Sensor D6F-P A Compact, High-performance Flow Sensor with Dust Segregation Structure. Built in Dust Segregation System (DSS) with cyclone flow structure, diverts particulates from sensor

More information

COMPACT FLAT SIZE FOR AUTOMOTIVE

COMPACT FLAT SIZE FOR AUTOMOTIVE PACT FLAT SIZE FOR AUTOMOTIVE RELAYS RoHS compliant FEATURES Compact flat type Flat size enables it to be built-in switch units. PC board terminal type: 9.5 mm.374 inch Surface-mount terminal

More information

Differential Pressure Gauges (701P Series)

Differential Pressure Gauges (701P Series) Applications Equipped two Process Connections Indicating low and high pressure Measuring differential pressure as well as liquid or flow levels Recommended to use 3-way & 5-way valve manifold Pressure

More information

TOWA SEIDEN INDUSTRIAL CO., LTD.

TOWA SEIDEN INDUSTRIAL CO., LTD. INSTRUCTION MANUAL SOUNDING LEVEL METER MODEL: TLX-120AP/200AP Meanings of indications for safety used in this Instruction Manual are as follows. WARNING: Indicates that improper handling assumes the risk

More information

Digital Flow Switch (Sensor Part) Operation Manual

Digital Flow Switch (Sensor Part) Operation Manual Digital Flow Switch (Sensor Part) Operation Manual For Air PF2A 50/5 Series PF2A 5/ 52/ 55 Series For Water PF2W /520/50 Series PF2W 5 Series For Water (High Temperature Fluid Type) PF2W T/520T/50T Series

More information

Low Profile Insertion Vortex

Low Profile Insertion Vortex Low Profile Insertion Vortex Product Features The same insertion meter can measure Steam, Gases or Liquids. Standardize on an insertion bar that can measure line sizes 2 24 Heavy Duty & Maintenance Free

More information

Detector (for water measurement applications)

Detector (for water measurement applications) WaterMAG Smart Electromagnetic Flowmeter Detector (for water measurement applications) Model MGW18 OVERVIEW The WaterMAG electromagnetic flowmeter detector is a high performance, highly reliable flowmeter

More information

COMPACT FLAT SIZE FOR AUTOMOTIVE

COMPACT FLAT SIZE FOR AUTOMOTIVE PACT FLAT SIZE FOR AUTOMOTIVE RELAYS RoHS compliant FEATURES Compact flat type Flat size enables it to be built-in switch units. PC board terminal type: 9.5 mm.374 inch Surface-mount terminal

More information

* E8MS-N1 is only 1-channel pressure sensor controller. E80-C2 can be used. For more details, please refer to E80 catalogue.

* E8MS-N1 is only 1-channel pressure sensor controller. E80-C2 can be used. For more details, please refer to E80 catalogue. Authorised Distributors:- ASH & ALAIN INDIA PVT LTD S-, F.I.E.E., Okhla Industrial Area, Phase-ii, New Delhi-(India) Tel : -7977 Fax : -7977 E-mail : sales@ashalain.com Sensor Four-Input-Channel Sensor

More information

Smart Pressure Transmitter

Smart Pressure Transmitter DOC. NO.: C3100L-E16B Smart Pressure Transmitter with Diaphragm Seal MODEL APT3100L DUON System Co., Ltd. 298-29, GONDAN-RO, GUNPO-SI, GYEONGGI-DO, KOREA 15809 Tel : +82-31-3-6100 Fax : +82-31-29-7200

More information

Transmitters: Relay Valve VR4151/4152

Transmitters: Relay Valve VR4151/4152 Relay Valve VR4151/4152 Appropriate output sequences are affected according to the signal received from the mechanical valve. VR4151 VR4152 Precautions Be sure to read before handling. Refer to pages 5-11-2

More information

Electro-Pneumatic Regulators. Electronic Vacuum Regulators

Electro-Pneumatic Regulators. Electronic Vacuum Regulators Electro-Pneumatic Regulator Electronic Vacuum Regulator Stepless control of air pressure proportional to an electrical signal Added Fieldbus compliant specifications to New Series Reduced wiring Series

More information

10 AMP POWER RELAY. Breakdown voltage* 2. Operate time* 3 (at nominal voltage) Shock resistance. Vibration resistance. Unit weight

10 AMP POWER RELAY. Breakdown voltage* 2. Operate time* 3 (at nominal voltage) Shock resistance. Vibration resistance. Unit weight VDE 2c, 3c AMP POWER RELAY RELAYS 2. 1.72 FEATURES Interchangeable with existing models Long life and high reliability High contact capacity up to A 20 Available with plug-in/solder and quick-connect terminals

More information

Types E2 and D2. Types Q and L. Including products with: Digital Precision Pressure Gauges

Types E2 and D2. Types Q and L. Including products with: Digital Precision Pressure Gauges JJ Types E-Ex and D-Ex JJ Types E2 and D2 JJ Type J JJ Type P JJ Types Q and L Including products with: Digital Precision Pressure Gauges DS_Digital_Precision_Pressure_gauges 01/2016 Digital precision

More information

Electro-Pneumatic Regulators. Electronic Vacuum Regulators

Electro-Pneumatic Regulators. Electronic Vacuum Regulators Electro-Pneumatic Regulator Electronic Vacuum Regulator New Reduced wiring Applicable Fieldbus protocols Compact & light Weight: g Note ) (ITV) Power consumption: 4 W Note ) or less Electro-Pneumatic Regulators

More information

display on the wall or in a panel away from the inline sensor SE30 for easy meter reading.

display on the wall or in a panel away from the inline sensor SE30 for easy meter reading. Analogue Flow Rate Indicator, DN 15...; PN 1...16 Advantages / Benefits Reduced costs of ownership up to 6% Economic integration in pipe systems without any additional piping Shows flow rate with a large

More information

1. Preface For best results, please refer to this manual before using this product. 2. Safety precautions Model Precautions DFS-1 The maximum pressure

1. Preface For best results, please refer to this manual before using this product. 2. Safety precautions Model Precautions DFS-1 The maximum pressure PB97001E-A 2011/06/28 INSTRUCTION MANUAL FOR DIGITAL FLOW SENSOR DFS-*-O/W 1. Preface 2. Safety precautions 3. Installation tips Contents 4. Necessary considerations 5. Description of Model-No. 6. Wiring

More information

STEEMCO Flowmeter for Steam

STEEMCO Flowmeter for Steam STEEMCO Flowmeter for Steam Typical Applications The STEEMCO flow meters measure the flow of saturated and superheated steam within the process industries, including chemical, petro-chemical, pharmaceutical

More information

/OVAL OPERATION MANUAL. Eggs DELTA Pulse. Vortex Flow Monitor MODEL : FLP? L A G 1 2 FLP? L?

/OVAL OPERATION MANUAL. Eggs DELTA Pulse. Vortex Flow Monitor MODEL : FLP? L A G 1 2 FLP? L? Vortex Flow Monitor /OVAL Eggs DELTA Pulse OPERATION MANUAL MODEL : FLP? L A G 1 2 FLP? L? SA G 1 2 FLP? L? G 1 2 P N A Every Sparling/OVAL vortex flow monitor Eggs DELTA Pulse is fabricated and shipped

More information

Time Delta S Fixed Transit-Time Flow Meter System

Time Delta S Fixed Transit-Time Flow Meter System Fixed Transit-Time Flow Meter System Key Features Dynamic flow correction Simple configuration Digital outputs Enhanced anti-bubble measurement technology (ABM) Rugged and reliable Maintenance free The

More information

Liquid Turbine Flow Meter OwnerÊs Manual

Liquid Turbine Flow Meter OwnerÊs Manual Liquid Turbine Flow Meter OwnerÊs Manual Manual LWGY-G Rev.1.0 Content 1.0 GENERAL INFORMATION... 1 2.0 SPECIFICATIONS... 2 3.0 OPERATION CONDITIONS... 3 4.0 CAUTIONS FOR INSTALLATION... 4 5.0 DIMENSION...

More information

SL40 Flow Rate Measurement

SL40 Flow Rate Measurement SL40 Flow Rate Measurement ESS3271 Lecture V-notch weir Pump Rotameter Vortex Shedding Optical sensing Electro-magnetic sensing V-Notch Weir (1) (2) Rotameter Very commonly used Drag force = weight + buoyancy

More information

10 switches simultaneously. The settings of the master sensor (source of copy) can be copied to the slave sensors. Reducing setting labor

10 switches simultaneously. The settings of the master sensor (source of copy) can be copied to the slave sensors. Reducing setting labor 2-Color Display High-Precision Digital Pressure Switch ZSE ISE RoHS ZSE ISE IP65 ZSE40 ISE40 M8 connector type ZSE10 ISE10 ISE70 ZSE80 ISE80 PS ISA3 ISA2 ISE35 Applicable Air, Non-corrosive gas, Non-flammable

More information

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate 1 919 1919P01 QBM65/C, QBM75-1U/C Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate Highly accurate measurements with calibration certificate Simple and quick

More information

Pressure sensor for liquid and gaseous media QBE620-P...

Pressure sensor for liquid and gaseous media QBE620-P... 1 904 Pressure sensor for liquid and gaseous media QBE620-P... Pressure sensor for the measurement of positive pressure in HVAC applications. Piezo-resistive system of measurement DC 0...10 V output signal

More information

Rotary Actuator. New RoHS. New. Vane Type 10, 15, 20, 30, 40. Many combinations available! Series CRB 2. Standard type/series CRB2

Rotary Actuator. New RoHS. New. Vane Type 10, 15, 20, 30, 40. Many combinations available! Series CRB 2. Standard type/series CRB2 Rotary Actuator Vane Type 1, 15, 2, 3, 4 Standard Type Free Mount Type Many combinations available! Standard type/series Piping ports are located on the flat surface. Fittings can be secured firmly, piping

More information

ST3000 Series 900 Smart Transmitter Differential Pressure Transmitters

ST3000 Series 900 Smart Transmitter Differential Pressure Transmitters ST3000 Series 900 Smart Transmitter Differential Pressure Transmitters Model STD910/STD920/STD930/STD960/STD921/STD931/STD961 OVERVIEW The ST3000 Smart Transmitter is a microprocessor-based smart transmitter

More information