Flow Measurement. SITRANS F US Clamp-on. SITRANS FUP1010 (Portable) 4/318 Siemens FI Overview
|
|
- Britton Gardner
- 5 years ago
- Views:
Transcription
1 Flow Measurement Siemens G 2011 Overview SITRNS FUP1010 clamp-on non-intrusive ultrasonic flow transmitter offers maximum versatility plus battery power for portable field use. It can operate in either WideBeam transit time or reflexor (oppler) mode, making it suitable for virtually any liquid, even those with high aeration or suspended solids. SITRNS FUP1010 is available in single and dual channel or dual path configurations, with IP67 weatherproof enclosure. pplication SITRNS FUP1010 is suitable for a wide variety of liquid applications, including the following: Water industry -Raw water -Potable water - hemicals Wastewater industry -Raw sewage - ffluent -Sludges - Mixed liquor - hemicals HV industry - hillers - ondensers - Hot and cold water systems - Thermal energy rate and total Power industry - Nuclear - Fossil - Hydroelectric Processing industry - Process control -Batching - Rate indication - Volumetric and mass measurement Benefits Battery power facilitates field use; the meter is easily transported from one installation to another saving time for surveys, monitoring and temporary installations Weatherproof enclosure can be used outdoors and left in place without concern for rain damage Rugged plastic case enables it to withstand rough treatment that would destroy most other meters Versatility - there is no need to change meters when operating conditions change asy installation; no need to cut pipe or stop flow Minimal maintenance; external sensors do not require periodic cleaning No moving parts to wear or foul No pressure drop or energy loss Wide turn-down ratio hoice of single or dual channel models minimizes total cost ZeroMatic Path automatically sets zero without stopping flow and reduces zero drift, even at low flow Note that the SITRNS FUP1010 flow transmitter is not available with hazardous area approvals esign IP67 Weatherproof / Impact resistant enclosure constructed of mineral reinforced copolymer polypropylene - Single channel - ual channel / dual path Function Integral 33 button keypad and large (128 x 20 pixel) graphic display visible up to 12 m (0 ft) away urrent, voltage, frequency and RS232 outputs (see specification section for details) Optional current, voltage and temperature inputs (see specification section for details) ZeroMatic Path automatically sets zero Bi-directional flow operation 1 MByte data logger with both site and data logger storage nglish, Spanish, German, Italian and French language options /318 Siemens FI
2 Siemens G 2011 Flow Measurement Technical specifications Input Flow range ± 12 m/s (± 0 ft/s), bidirectional Pipe size 6. mm 9.1 m ( ) Inputs, single channel Output Outputs ccuracy ccuracy Batch repeatability Rated operation conditions egree of protection Weatherproof/impact resistant Liquid temperature Standard Optional mbient temperature esign imensions Weight Power supply Power Battery operation Indication and operation ata logger memory Site storage memory isplay Keypad Language options ertificates and approvals Unclassified locations lassified locations urrent: 2x 20 m Voltage: 2 x 0 10 V Temperature: 2 x wire 1 kω RT urrent: 2x 20 m (1 kω at 30 V ) Voltage: 2 x 0 10 V (5 kω minimum) Status larm: x SPT Relays Frequency: 2 x Hz RS232 ± 0.5 % 2 % of flow, for velocities greater than 0.3 m/s (1 ft/s) ± m/s (± ft/s), for velocities less than 0.3 m/s (1 ft/s) ± 0.15 % of flow, for velocities greater than 0.3 m/s (1 ft/s) ± m/s (± ft/s), for velocities less than 0.3 m/s (1 ft/s) IP ( F) ( F) (0 10 F) see "System info and selection guide" see diagrams Internal rechargeable battery 7 hours 1 MByte 50 sites minimum 128 x 20 pixel L with backlight 33 keypad buttons with tactile feedback nglish, Spanish, German, Italian, French UL ULc M irective 200/108/ TX irective 9/9/ Siemens FI /319
3 Flow Measurement Siemens G 2011 Standard MLFB for quick delivery on SITRNS FUP1010 Portable (excluding energy) Selection and Ordering data Order No. Order ode IP67 weatherproof battery powered Number of channels/ultrasonic paths Single channel 1 ual channel/ual path 2 L) 7M Standard flowmeter types and I/O configurations Standard I/O - 2 x m analog in -2xRT input Sensor cables No sensor cable 1 x PV Jacket cable, length 6 m/20 ft B 2 x PV Jacket cable, length 6 m/20 ft 1 x PV Jacket cable, length 15 m/50 ft 2 x PV Jacket cable, length 15 m/50 ft RT temperature Sensor (Mounting hardware & cable included) No RTs 0 1 x standard clamp-on RT, 6 m/20 ft cable 5 2 x standard clamp-on RT with 6 m/20 ft cable 6 1 x standard clamp-on RT with 15 m/50 ft cable 7 2 x standard clamp-on RT with 15 m/50 ft cable 8 Battery charger options No battery charger 0 harger Type for urope (7/7) 1 harger Type G for U.S. (NM 5-15P) 5 Sensor for channel 1 (includes pipe mounting kit and spacer bar for indicated max. outer diameter listed) See "Sensor selection charts" for specifications. no sensor 2 universal Trackmount and straps B B3 universal Trackmount and straps 125 mm (5 ) 3 universal Mounting frame and 300 mm (13 ) 3 universal Mounting frame and 2 universal Mounting frame and F 1H (high precision) Mounting frame and M 2H (high precision) Mounting frame and N 1H (high precision) Mounting frame and P H (high precision) Mounting frame and R oppler to 12" with strap kit S (not for IP65 (NM 7)) 1H High temperature range Z 10 / 220 F HP 2) P 1 P Selection and Ordering data Order No. Order ode IP67 weatherproof battery powered L) 7M Sensor for channel 2 (includes pipe mounting kit and spacer bar for indicated max. outer diameter listed) See "Sensor selection charts" for specifications. no sensor 2 universal Trackmount and straps B B3 universal Trackmount and straps 125 mm (5 ) 3 universal Mounting frame and 300 mm (13 ) 3 universal Mounting frame and 2 universal Mounting frame and F 1H (high precision) Mounting frame and M 2H (high precision) Mounting frame and N 1H (high precision) Mounting frame and P 2H (high precision) Mounting frame and Q oppler to 12" with strap kit S (not for IP65 (NM 7)) 1H High temperature Z Q 1 P range 10 / 220 F HP 2) pprovals: No options (UL, ULc, by default) Standard MLFB product offering represents to 6 weeks delivery time L) Subject to export regulations L: N, N: 3991X /320 Siemens FI
4 Siemens G 2011 Flow Measurement IP67 weatherproof battery powered Number of channels/ultrasonic paths Single channel 1 ual channel/ual path 2 L) 7M3510- Standard flowmeter types and I/O configurations Standard I/O - Reflexor capable - Graphic display - 2 x V -2x...20 m - 2 x pulse outputs - x status logic - 2 x m analog in - 1 x RT per channel Sensor cables (select proper quantity of active channels) No sensor cable IP67 (weatherproof) only 1 x PV-jacket, length 6 m (20 ft) B (for IP67 NM 6) 2) 2 x PV-jacket, length 6 m (20 ft) (for IP67 NM 6) 2) 1 x PV-jacket, length 15 m (50 ft) (for IP67 NM 6) 2) 2 x PV-jacket, length 15 m (50 ft) (for IP67 NM 6) 2) RT temperature sensor (for type 3 meter only, mounting hardware and cable included) No RTs 0 IP67 (weatherproof) only 1 x standard clamp-on RT (NM 6) with 6 m (20 ft) cable 1) 5 2 x standard clamp-on RT (NM 6) with 6 6 m (20 ft) cable 1) 1 x standard clamp-on RT (NM 6) with 7 15 m (50 ft) cable 1) 2 x standard clamp-on RT (NM 6) with 8 15 m (50 ft) cable 1) Battery charger options no battery charger 0 harger Type for urope (7/7) 1 harger Type for ustralia (S3112) 2 harger Type for U.K. (BS1363) 3 harger Type J for Japan (JIS8303) harger Type G for U.S. (NM 5-15P) 5 harger Type L for Switzerland (SV1011) IP67 weatherproof battery powered L) 7M Sensor for channel 1 Including pipe mounting tracks for sizes & B sensors indented for pipe with a O less than 125 mm (5") and mounting frame/spacer bars for sizes, & sensors. Straps provided are for the indicated maximum O listed below. Strap kits are available to accommodate larger pipes (refer to spare part list). Refer to "Sensor Selection harts" for the sensor suitability of pipe size and wall thickness. no sensor 2 universal Trackmount and straps B B3 universal Trackmount and straps 125 mm (5 ) 3 universal Mounting frame and 300 mm (13 ) 3 universal Mounting frame and 2 universal Mounting frame and F For the following 1H to H sensors, temperature range is -0 to 65 (-1 F to 150 F), nominal 21 (70 F): 2H (high precision) Trackmount and straps H 3H (high precision) Trackmount and straps J B1H (high precision) Trackmount and straps K 125 mm (5 ) B2H (high precision) Trackmount and straps L 125 mm (5) 1H (high precision) Mounting frame and M 2H (high precision) Mounting frame and N 1H (high precision) Mounting frame and P 2H (high precision) Mounting frame and Q H (high precision) Mounting frame and R oppler to 12 with chain kit S High temperature sensor size 2 for Z P 1 up to 230 (6 F) (30 to 200 mm diam. (1.18 to 7.67 inch diam.)) High temperature sensor size 3 for Z P 1 B up to 230 (6 F) (150 to 610 mm diam. (5.90 to 2 inch diam.)) High temperature sensor size for Z P 1 up to 230 (6 F) (00 to 1200 mm diam. (15.75 to 7.25 inch diam.)) L) Subject to export regulations L: N, N: 3991X Siemens FI /321
5 Flow Measurement Siemens G 2011 IP67 weatherproof battery powered Sensor for channel 1 (continued) L) 7M For the following B1H to H sensors, temperature range is -1 up to 10 (30 F up to 220 F), nominal 65 (150 F): B1H (high temperature range HP) Z P 1 K B2H (high temperature range HP) Z P 1 L 1H (high temperature range HP) Z P 1 M 2H (high temperature range HP) Z P 1 N 1H (high temperature range HP) Z P 1 P 2H (high temperature range HP) Z P 1 Q H (high temperature range HP) Z P 1 R Sensor for channel 2 (includes pipe mounting kit and spacer bar for indicated max. outer diameter listed) See "Sensor selection charts" for specifications. no sensor 2 universal Trackmount and straps B B3 universal Trackmount and straps 125 mm (5 ) 3 universal Mounting frame and 300 mm (13 ) 3 universal Mounting frame and 2 universal Mounting frame and F For the following 1H to H sensors, temperature range is -0 to 65 (-1 F to 150 F), nominal 21 (70 F): 2H (high precision) Trackmount and straps H 3H (high precision) Trackmount and straps J B1H (high precision) Trackmount and straps K 125 mm (5 ) B2H (high precision) Trackmount and straps L 125 mm (5") 1H (high precision) Mounting frame and M 2H (high precision) Mounting frame and N 1H (high precision) Mounting frame and P 2H (high precision) Mounting frame and Q H (high precision) Mounting frame and R oppler to 12 with chain kit S IP67 weatherproof battery powered Sensor for channel 2 (continued) High temperature sensor size 2 for up to Z Q (6 F) (30 to 200 mm diam. (1.18 to 7.67 inch diam.)) High temperature sensor size 3 for up to Z Q 1 B 230 (6 F) (150 to 610 mm diam. (5.90 to 2 inch diam.)) High temperature sensor size for up to Z Q (6 F) (00 to 1200 mm diam. (15.75 to 7.25 inch diam.)) For the following B1H to H sensors, temperature range is -1 up to 10 (30 F up to 220 F), nominal 65 (150 F): B1H (high temperature range HP) Z Q 1 K B2H (high temperature range HP) Z Q 1 L 1H (high temperature range HP) Z Q 1 M 2H (high temperature range HP) Z Q 1 N 1H (high temperature range HP) Z Q 1 P 2H (high temperature range HP) Z Q 1 Q H (high temperature range HP) Z Q 1 R pprovals: No options (UL, ULc, by default) ( F) ( F) L) Subject to export regulations L: N, N: 3991X. Selection and Ordering data ) Subject to export regulations L: N, N: R99H. L) 7M Order No. Operating Instructions for SITRNS FUP1010 nglish IP67 Weatherproof ) German IP67 Weatherproof ) This device is shipped with a Quick Start Guide and a containing further SITRNS F literature. ll literature is also available for free at: /322 Siemens FI
6 Siemens G 2011 Flow Measurement Selection and Ordering data Further designs Please add "-Z" to Order No. and specify Order code(s). Languages (Meter and ocumentation), nglish (default). ll languages now come standard in all flowmeters Wet flow transfer calibration (priced on request) 6 point calibration 2/water (Price per channel) 2SS0 pipe 3S0 pipe S0 pipe SS0 pipe 6S0 pipe 6SS0 pipe 6S120 pipe 8S0 pipe 8SS0 pipe 8S120 pipe 10S Standard pipe 10S0 pipe 10SS0 pipe 12S Standard pipe 12S0 pipe 1S30 pipe 1S0 pipe 16S Standard pipe 16S0 pipe 18S Standard pipe 20S20 pipe 20S30 pipe 2S Standard pipe 2S20 pipe 2S30 pipe 30S Standard pipe 36S Standard pipe Other pipe, other liquid, additional points, witness 1x Insertion RT with thermowell and lagging 2x Insertion RT with thermowell and lagging Tag name plate Stainless steel tag with 3.2 mm (0.13 inch) character size (68 characters max.) Order code Y28 M1 M1B Y19 1) Supplied spacer bar supports pipes up to 1050 mm (2 inches). For pipes larger than 1050 mm (2 inches) purchase also, spare part 7M3960-0MS0 (1012BN-). 2) Supplied spacer bar supports pipes up to 750 mm (30 inches). For pipes larger than 750 mm (30 inches) purchase also, spare part 7M3960-0MS0 (1012BN-). MLFB example pplication example general survey portable flowmeter is required for pipes sizes ranging from mm (3"... 20") with both cast iron and steel material. oppler may be required as liquid may be moderately aerated. Requires language support for German. MLFB Order No.: 7M3511-2B01-00-Z B10 SITRNS FUP1010 meter 7 M family IP67 weatherproof 1 ual channel 2 Portable Type 3 I/O with oppler capable, temperature 1 x PV-Jacket, length 6 m (20 ft) B No RTs required 0 harger Type for urope 1 (7/7) Sensor for N N 300 ( ) pipes Sensor for N N 600 ( ) pipes German language support B 1 0 Universal sensor selection chart Based on pipe size (pipes other than steel) Pipe size Order Outer diameter ode range (mm) Outer diameter range (inches) min. max. min. max. 2 B 12,7 50, B F High precision sensor selection chart Based on pipe wall thickness (steel pipes only) Pipe Wall Order Pipe Wall [mm] Pipe Wall [inches] ode min. max. min. max. 1H G 0,6 1, H H 1,02 1, H J 1,52 2, B1H K 2,03 3, B2H L 3,05, H M,06 5, H N 5,8 8, H P 8,13 11, H Q 11,18 15, H R 15,75 31, Siemens FI /323
7 Flow Measurement SITRNS FUP1010 Water and Liquid check metering kits Siemens G 2011 Overview There are two check kits available: SITRNS FUP1010 Water check metering kit for water and wastewater applications, and SITRNS FUP1010 Liquid check metering kit for liquid applications other than water. The kits have been developed especially for verifying the accuracy and performance of any brand or type of flowmeter. They can be used to verify the performance of meters based on any existing flow measurement principle: orifice, electromagnetic, ultrasonic, rotary piston, coriolis, etc. In addition, they measure practically all conductive or non-conductive clean or moderately aerated liquids or liquids with suspended solids. Benefits Performance check or verification of any type or brand of flowmeter Field use is facilitated by meter portability and 7 hours or normal battery operation. Weatherproof enclosure withstands even severe weather conditions 1 MByte datalogger capability downloadable to P via included RS232 cable Fast, easy and cost-efficient on-site measurement of any convoluted pipe from 20 to 1200 mm (0.75 to 8 ) elivered as an all inclusive kit in a sturdy rolling case that holds all the equipment needed to conduct performance and verification tests (cables, multiple sensors, flow transmitter etc.) pplication The SITRNS FUP1010 Water and Liquid heck Metering Kits measure practically all conductive or non-conductive clean or moderately aerated liquids or liquids with suspended solids.this basic feature enables the performance check and verification of existing meters used in various water and wastewater applications such as: Raw Water and sewage Potable water hemicals ffluent and sludges Process control Batching Rate indication Hot and cold water systems esign IP67 weatherproof/impact resistant enclosure, constructed of mineral reinforced copolymer polypropylene Single channel Function Integral 33 button keypad and large (128 x 20 pixel) graphic display visible up to 12 m (0 ft) away urrent, voltage, frequency and RS232 outputs (see Technical specification section for details) Optional current, voltage and temperature inputs (see specification section for details) ZeroMatic Path automatically sets zero Bi-directional flow operation 1 MByte data logger with both site and data logger storage nglish, Spanish, German, Italian and French language options Technical specifications Pipe sizes Water heck Metering Kit mm ( ) Liquid heck Metering Kit mm ( ) ccuracy ±0.5 %... ±2.0 % of flow rate Flow range 12 m/s (0 ft/s) bidirectional Media temperature ( F) nclosure ratings IP67 (Weatherproof) See page /319 for complete technical specifications erificates and approvals Unclassified locations UL ULc lassified locations MV irective 200/108/ TX irective 9/9/ /32 Siemens FI
8 Siemens G 2011 Flow Measurement SITRNS FUP1010 Water and Liquid check metering kits Selection and Ordering data Order No. SITRNS FUP1010 Water heck Metering Kit QO:FUPW-WWKIT ) ontent of delivery 1 Single channel portable submersible flow transmitter 1 pair Universal sensor 3 1 pair Universal sensor 2 1 pair oppler sensors 1 pair Mounting zclamp (2 mounting zclamp chains) 1 Ladder chain 1 Battery charger 1 pair 20 ft sensor cable 1 able WP/WP to P 1 PinStop spacer bar (universal) 1 Flow case 1 Flowmeter manual 1 Laminated card set 1 ertificate of intrinsic calibration Selection and Ordering data Order No. SITRNS FUP1010 Liquid heck Metering Kit QO:FUS-LIQKIT ) ontent of delivery 1 Single channel portable submersible transmitter 1 pair Universal sensor B3 1 pair Universal sensor 3 1 pair Universal sensor 3 1 pair Universal sensor 2 1 pair oppler sensors 1 pair Sensor cables 6m (20 ft) 1 pair Mounting track 1 pair Mounting zclamp 1 Spacer bar (portable) 1 Ladder chain 1 Battery charger 1 RS232 cable for P connection 1 Flow case 1 lamp-on flowmeter manual 1 Flowmeter manual 1 Laminated card set 1 ertificate of intrinsic calibration ) Subject to export regulations L: N, N: R99H. Siemens FI /325
9 Flow Measurement Siemens G 2011 Overview pplication SITRNS FU1010 is ideally suited to thermal energy / power industry applications, including: hilled water sub-metering Hot water sub-metering ondenser water Glycol Thermal storage Lake source cooling SITRNS FU1010 is a highly accurate clamp-on non-intrusive ultrasonic flow transmitter for revenue grade thermal energy sub-metering and energy efficiency distribution monitoring, with a real time coefficient of performance (OP) for HV systems. SITRNS FU1010 is available in single and dual channel or dual path configurations, with your choice of IP65 (NM X) dedicated wall mount or IP0 (NM 1) portable enclosures. Benefits Measures energy rate and total consumption with highest accuracy available ccurately measures at both low flow rates and low differential temperatures asy installation; no need to cut pipe or stop flow Minimal maintenance; external sensors do not require periodic cleaning No moving parts to foul or wear No pressure drop or energy loss Wide turn-down ratio hoice of single or dual channel / dual path or dual mode operation: - ual channel operation reduces the cost for the system on a per channel measurement basis and permits measuring hot and chilled water lines at the same time - ual path capability insures high flow measurement accuracy on installations with less than desirable piping runs bility to operate in either Wide-Beam Transit-time or reflexor (oppler) mode for applications with high aeration ZeroMatic Path automatically sets zero without stopping flow and reduces zero drift, even at low flow esign SITRNS FU1010 is available in three configurations: IP65 (NM X) wall mount enclosure constructed of fiberglass reinforced polyester with stainless steel hardware and polyester keypad - Single channel - ual channel / dual path IP0 (NM 1) Portable impact resistant enclosure constructed of mineral reinforced copolymer polypropylene - ual channel / dual path Function Flow transmitter has an integral 33 button keypad and large (128 x 20 pixel) graphic display visible up to 12 m (0 ft) away -wire 1000 Ω platinum RT s for supply and return temperature measurements are precision matched to within 0.01 (0.02 F) Temperature is factory calibrated with built-in field calibrator. Built-in energy/btu mode etection of aeration and cavitation caused by worn or damaged impellers, misaligned shafts, etc. Reverse flow and empty pipe detection hiller efficiency analysis: accepts an independent analog input representing kw usage for calculation of the following functions which can be selected for data logging or output purposes: - ooling load (kw/ton) - oefficient of performance (OP) - nergy efficiency ratio (R) Optional current inputs igital communication options: - MOBUS / Metasys N2 (IP65 (NM X) only) - RS232 Serial digital port (standard) ZeroMatic Path automatically sets zero Bi-directional flow operation 1 MByte data logger with both site and data logger storage nglish, Spanish, German, Italian and French language options /326 Siemens FI
10 Siemens G 2011 Flow Measurement Technical specifications Input Indication and operation Flow range 0 12 m/s (0 0 ft/s), bi-directional Flow sensitivity m/s (0.001 ft/s) Pipe size 6. mm 9.1 m ( ) Inputs per channel urrent: 2x 20 m Voltage: 2 x 0 10 V Temperature: 2 x wire 1 kω RT Totalizer commands (clear/hold) Output Standard outputs urrent: 2x 20 m (1 kω at 30 V ) Voltage: 2 x 0 10 V (5 kω minimum) Status larm: x SPT Relays Mercury wetted relays Frequency: 2 x Hz RS232 Optional outputs xpanded I/Os ( additional m outputs) with form c relays xpanded I/Os with Mercury wetted relays ccuracy ata logger memory isplay Keypad Language options ertificates and approvals edicated enclosures FM and S ratings -TIK TX ratings INMTRO ratings 1 Mbyte of storage 128 x 20 pixel L with backlight 33 keypad buttons with tactile feedback nglish, Spanish, German, Italian, French Transmitter NI lass I, iv 2 S lass II, iv 2 Sensor I.S. lass I, II, iv 1 M irective 200/108/ TX irective 9/9/ Transmitter: x II (1) G [x ia] II x II 3 (1) G x n [ia] II T5 Sensors: x II 1 G x ia II T5 Transmitter: [BR-x ia] II BR-x nc [ia] II T5 ccuracy Batch repeatability ± 0.5 % % of flow, for velocities greater than 0.3 m/s (1 ft/s) ± m/s (± ft/s), for velocities less than 0.3 m/s (1 ft/s) ± 0.15 % of flow, for velocities greater than 0.3 m/s (1 ft/s) ± m/s (± ft/s), for velocities less than 0.3 m/s (1 ft/s) Portable enclosures Sensors: BR-x ia II T5 UL ULc M irective 200/108/ TX irective 9/9/ Rated operation conditions egree of protection Wall mount enclosure: IP65 (NM X) Portable enclosure: IP0 (NM 1) Liquid temperature Standard ( F) Optional ( F) Sensor temperature Standard ( F) Optional ( F) mbient temperature ( F) esign imensions see "System info and selection guide" Weight see diagrams Power supply edicated V, Hz, 30 V or V Portable enclosure Rechargeable battery Siemens FI /327
11 Flow Measurement Siemens G 2012 Standard MLFB for quick delivery on SITRNS FU1010 (nergy system) Selection and Ordering data Order No. Order code L) 7 M esign edicated IP65 (NM X) wall mount 0 K K R 0 2 Portable IP0 (NM 1) Battery powered 2 K K R 0 1 Number of channels/ultrasonic paths edicated meters Single channel 1 Portable meters ual channel/ual path Flowmeter functions and I/O configurations Portable Standard I/O - nergy efficiency OP/R output - 2x -20m analog input edicated Standard I/O - Reflexor apability - nergy efficiency OP/R output - 2x -20m analog input Meter power options V (edicated only) harger Type for urope (7/7) harger Type K for U.S. (NM 5-15P) G No charger J ommunication options RS232 (standard) 0 RT temperature sensor pair No RTs (Note: Temperature input is required for nergy systems) 0 1x Pair Std clamp-on RT (NM X only) 3) 1 2x Pair Std clamp-on RT (For ual hannel NM X only) 3) 2 1x Pair Std clamp-on RT (For NM 12 Portable) 3) 3 2x Pair Std clamp-on RT (For ual hannel NM 1 Portable) 3) 1x Insertion RT with Thermowell and Lagging 2x Insertion RT with Thermowell and Lagging Sensor for channel 1 (includes pipe mounting kit and spacer bar for indicated max. O listed) See "Sensor selection charts" for specifications. no sensor 2 universal Trackmount and 75 mm (3") B B3 universal Trackmount and 125 mm (5") 3 universal Mounting frame and 300 mm (13") 3 universal Mounting frame and 600 mm (2") 2 universal Mounting frame and 1200 mm (8") 1)) F 1H (high precision) Mounting frame and 1200 mm (8") ) M 2H (high precision) Mounting frame and 1200 mm (8") ) N 1H (high precision) Mounting frame and 1200 mm (8") ) P 2H (high precision) Mounting frame and 1200 mm (8") ) Q oppler to 12" with strap kit (not for IP65 (NM7)) S 1H High temperature range 10 /220 F HP 2) Z P 1 P L) Subject to export regulations L: N, N: 3991X. F M 1 M 1 B /328 Siemens FI Modification 3/2012
12 Siemens G 2011 Flow Measurement Selection and Ordering data Order No. Order code L) 7 M Sensor for channel 2 (includes pipe mounting kit and spacer bar for indicated max. O listed) See "Sensor selection charts" for specifications. no sensor 2 universal Trackmount and 75 mm (3") B B3 universal Trackmount and 125 mm (5") 3 universal Mounting frame and 300 mm (13") 3 universal Mounting frame and 600 mm (2") 2 universal Mounting frame and 1200 mm (8") 1)) F 1H (high precision) Mounting frame and 1200 mm (8") ) M 2H (high precision) Mounting frame and 1200 mm (8") ) N 1H (high precision) Mounting frame and 1200 mm (8") ) P H (high precision) Mounting frame and 1200 mm (8") ) R oppler to 12" with strap kit (not for IP65 (NM7)) S 1H High temperature range 10 /220 F HP 2) Z Q 1 P pprovals UL/Portable 0 FM, S,, edicated 1 1) Supplied spacer bar supports pipes up to 1050 mm (2 inches). For pipes larger than 1050 mm (2 inches) purchase also, spare part 7M3960-0MS0 (1012BN-) 2) Supplied spacer bar supports pipes up to 750 mm (30 inches). For pipes larger than 750 mm (30 inches) purchase also, spare part 7M3960-0MS0 (1012BN-) 3) Requires two R** cables per one RT pair ) 600 mm (2") for portable systems only L) Subject to export regulations L: N, N: 3991X. Standard MLFB product offering represents to 6 weeks delivery time For sensor and RT cables for quick delivery see tables at end of section Siemens FI /329
13 Flow Measurement Siemens G 2011 edicated IP65 (NM X) wall mount Portable IP0 (NM 1) Battery powered L) 7M3500- L) 7M Number of channels/ultrasonic paths edicated meter edicated meter Single channel 1 ual channel/ual path 2 Portables ual channel/ual path Flowmeter functions and I/O configurations Portable Standard I/O - Reflexor capability - Graphic display - 2 x V - 2 x m - 2 x pulse output - x status logic - nergy efficiency OP/R output - 2 x m analog input edicated Standard I/O F - Reflexor capability - Graphic display - 2 x V - 2 x m - 2 x pulse output - x relay type - nergy efficiency OP/R output - 2 x m analog input Standard I/O with Mercury wetted relays Z J 1 xtended output adder plus standard inputs Z J 1 B ( additional m outputs) and form relay xtended output adder plus standard inputs Z J 1 ( additional m outputs) and Mercury wetted relays Meter power options V (edicated only) V (edicated only) B harger Type for urope (7/7) harger Type for ustralia (S3112) harger Type for U.K. (BS1363) harger Type J for Japan (JIS8303) F harger Type K for U.S. (NM 5-15P) G harger Type L for Switzerland (SV1011) H No harger J xternal hours battery with US plug for Portable Z K 1 xternal hours battery with uropean plug Z K 1 B for Portable ommunication options RS232 (standard) 0 MOBUS (dedicated only) 1 edicated IP65 (NM X) wall mount L) 7M3500- Portable IP0 (NM 1) Battery powered L) 7M RT temperature sensor (includes mounting hardware for pipes above 1.5 outer diameter) No RTs (Note: temperature input is required 0 for energy system) 1 x pair standard clamp-on RT (NM X only) 3) 1 2 x pair standard clamp-on RT (for dual channel NM X only) 3) 2 1 x pair standard clamp-on RT (NM 1 Portable) 3) 3 2 x pair standard clamp-on RT (for dual channel NM 1 Portable) 3) 1 x Insertion style RT with thermowell and 9 M 1 lagging 3) 2 x Insertion style RT with thermowell and 9 M 1 B lagging 3) Sensor for channel 1 Including pipe mounting tracks for sizes & B sensors indented for pipe with a O less than 125 mm (5") and mounting frame/spacer bars for sizes, & sensors. Straps provided are for the indicated maximum O listed below. Strap kits are available to accommodate larger pipes (refer to spare part list). Refer to "Sensor Selection harts" for the sensor suitability of pipe size and wall thickness. No sensor 2 universal Trackmount and straps B B3 universal Trackmount and straps 125 mm (5 ) 3 universal Mounting frame and 300 mm (13 ) 3 universal Mounting frame and 2 universal Mounting frame and 1200 mm (8 ) 1)) F For the following 1H to H sensors, temperature range is (-1 F F), nominal 21 (70 F): 2H (high precision) Trackmount and straps H 3H (high precision) Trackmount and straps J B1H (high precision) Trackmount and straps 125 mm (5 ) K 1) Supplied spacer bar supports pipes up to 1050 mm (2 inches). For pipes larger than 1050 mm (2 inches) purchase also, spare part 7M3960-0MS0 (1012BN-). 2) Supplied spacer bar supports pipes up to 750 mm (30 inches). For pipes larger than 750 mm (30 inches) purchase also, spare part 7M3960-0MS0 (1012BN-). 3) Requires two R** cables per one RT pair ) 600 mm (2") for portable systems only L) Subject to export regulations L: N, N: 3991X. /330 Siemens FI
14 Siemens G 2011 Flow Measurement edicated IP65 (NM X) wall mount Portable IP0 (NM 1) Battery powered L) 7M3500- L) 7M Sensor for channel 1 (continued) B2H (high precision) Trackmount and straps L 125 mm (5") 1H (high precision) Mounting frame and M 1200 mm (8 ) 3) 2H (high precision) Mounting frame and N 1200 mm (8 ) 3) 1H (high precision) Mounting frame and P 1200 mm (8 ) 2)3) 2H (high precision) Trackmount and straps Q 1200 mm (8 ) 2)3) H (high precision) Trackmount and straps R 1200 mm (8 ) 2)3) oppler to 12 with strap kit S High temperature sensor size 2 for up to 230 Z P 1 (6 F) (30 to 200 mm diam. (1.18 to 7.67 inch diam.)) High temperature sensor size 3 for up to 230 Z P 1 B (6 F) (150 to 610 mm diam. (5.90 to 2 inch diam.)) High temperature sensor size for up to 230 Z P 1 (6 F) (00 to 1200 mm diam. (15.75 to 7.25 inch diam.)) For the following B1H to H sensors, temperature range is -1 up to 10 (30 F up to 220 F), nominal 65 (150 F): B1H (high temperature range HP) Z P 1 K B2H (high temperature range HP) Z P 1 L 1H (high temperature range HP) Z P 1 M 2H (high temperature range HP) Z P 1 N 1H (high temperature range HP) 2) Z P 1 P 2H (high temperature range HP) 2) Z P 1 Q H (high temperature range HP) 2) Z P 1 R Sensor for channel 2 (includes pipe mounting kit for indicated max. outer diameter listed) See "Sensor selection charts" for specifications. no sensor 2 universal Trackmount and straps B B3 universal Trackmount and straps 125 mm (5 ) 3 universal Mounting frame and 300 mm (13 ) 3 universal Mounting frame and 2 universal Mounting frame and F 1200 mm (8 ) 1)3) Sensor for channel 2 (continued) edicated IP65 (NM X) wall mount Portable IP0 (NM 1) Battery powered L) 7M3500- L) 7M For the following 1H to H sensors, temperature range is -0 to 65 (-1 F to 150 F), nominal 21 (70 F): 2H (high precision) Trackmount and straps H 3H (high precision) Trackmount and straps J B1H (high precision) Trackmount and straps K 125 mm (5 ) B2H (high precision) Trackmount and straps L 125 mm (5") 1H (high precision) Mounting frame and M 1200 mm (8 ) 3) 2H (high precision) Mounting frame and N 1200 mm (8 ) 3) 1H (high precision) Mounting frame and P 1200 mm (8 ) 2)3) 2H (high precision) Mounting frame and Q 1200 mm (8 ) 2)3) H (high precision) Mounting frame and R 1200 mm (8 ) 2)3) oppler to 12 with strap kit S High temperature sensor size 2 for up to Z Q (6 F) (30 to 200 mm diam. (1.18 to 7.67 inch diam.)) High temperature sensor size 3 for up to Z Q 1 B 230 (6 F) (150 to 610 mm diam. (5.90 to 2 inch diam.)) High temperature sensor size for up to Z Q (6 F) (00 to 1200 mm diam. (15.75 to 7.25 inch diam.)) For the following B1H to H sensors, temperature range is -1 up to 10 (30 F up to 220 F), nominal 65 (150 F): B1H (high temperature range HP) Z Q 1 K B2H (high temperature range HP) Z Q 1 L 1H (high temperature range HP) Z Q 1 M 2H (high temperature range HP) Z Q 1 N 1H (high temperature range HP) 2) Z Q 1 P 2H (high temperature range HP) 2) Z Q 1 Q H (high temperature range HP) 2) Z Q 1 R pprovals FM/S/ edicated 1 UL/ULc/ Portable 0 1) Supplied spacer bar supports pipes up to 1050 mm (2 inches). For pipes larger than 1050 mm (2 inches) purchase also, spare part 7M3960-0MS0 (1012BN-). 2) Supplied spacer bar supports pipes up to 750 mm (30 inches). For pipes larger than 750 mm (30 inches) purchase also, spare part 7M3960-0MS0 (1012BN-). 3) 600 mm (2") for portable systems only L) Subject to export regulations L: N, N: 3991X. Siemens FI /331
15 Flow Measurement Siemens G 2011 Selection and Ordering data Further designs Please add "-Z" to Order No. and specify Order code(s). able assembly for sensors (add for # of channels) See "Sensor cable selection chart" able assembly for RTs (add for # of RTs) See "RT cable selection chart" able termination kit (for one cable pair) dedicated only Termination for standard, plenum and armored sensor cable Termination for submersible sensor cable Order code K.. R.. T01 T11 MLFB example pplication example dedicated clamp-on energy meter is required for two separate return lines. Both will use clamp-on RTs for the supply and return lines. power is available and data access will be via MOBUS communication. Pipe 1 is a N150 (6") schedule 0 carbon steel line Pipe 2 is a N 300 (12") ductile iron line MLFB Order No.: 7M N0-Z K03 + K05 + R03 + R05 + R02 + R03 RT cable termination kit for standard RT RT cable termination kit for submersible RT Insert RT cable termination kit Wet flow transfer calibration (priced on request) 6 point calibration 2/water (Price per channel) 2SS0 pipe 3S0 pipe S0 pipe SS0 pipe 6S0 pipe 6SS0 pipe 6S120 pipe 8S0 pipe 8SS0 pipe 8S120 pipe 10S Standard pipe 10S0 pipe 10SS0 pipe 12S Standard pipe 12S0 pipe 1S30 pipe 1S0 pipe 16S Standard pipe 16S0 pipe 18S Standard pipe T21 T31 T SITRNS FU1010 meter 7 M family IP65 (NM X) enclosure 0 ual channel 2 edicated Type 1 I/O option V power option MOBUS option 1 2 pairs of clamp-on RTs 2 Sensor code for 6" pipe N Sensor code for 12" pipe No approval required 0 30 m (100 ft) sensor cable for K 0 3 channel 1 61 m (200 ft) sensor cable for K 0 5 channel 1 30 m (100 ft) cable for RT 1 R m (200 ft) cable for RT 2 R m (50 ft) cable for RT 3 R m (100 ft) cable for RT R S20 pipe 20S30 pipe 2S Standard pipe 2S20 pipe 2S30 pipe 30S Standard pipe 36S Standard pipe Other pipe, other liquid, additional points, witness Tag name plate Stainless steel tag with 3.2 mm (0.13 inch) character size (68 characters max.) Y28 Y19 Selection and Ordering data Order code Operating Instructions for SITRNS FU1010 nglish NM X Wall mount ) German NM X Wall mount ) nglish IP0 NM 1 Battery powered German IP0 NM 1 Battery powered This device is shipped with a Quick Start Guide and a containing further SITRNS F literature. ll literature is also available for free at: ) Subject to export regulations L: N, N: R99H. /332 Siemens FI
16 Siemens G 2011 Flow Measurement Universal sensor selection chart Based on pipe size (pipes other than steel) Pipe size Order ode High precision sensor selection chart Sensor cable selection chart Outer diameter range (mm) Outer diameter range (inches) min. max. min. max. 2 B 12,7 50, B F Based on pipe wall thickness (steel pipes only) Pipe Wall Order Pipe Wall [mm] Pipe Wall [inches] ode min. max. min. max. 1H G 0,6 1, H H 1,02 1, H J 1,52 2, B1H K 2,03 3, B2H L 3,05, H M,06 5, H N 5,8 8, H P 8,13 11, H Q 11,18 15, H R 15,75 31, Sensor cable codes for length and type options able length m (ft) Standard (PV jacket) ( F) Submersible 1) (polyethylene jacket) ( F) Plenum Rated (teflon jacket) ( F) rmored 1) Order code 6 (20) K01 2) K11 K21 K31 15 (50) K02 K12 2) K22 K32 2) 30 (100) K03 2) K13 2) K23 K33 6 (150) K0 2) K1 K2 K3 61 (200) K05 K15 K25 K35 91 (300) K06 2) K16 K26 K ( F) 1) Submersible and armored sensor cable is not available for portable versions. 2) Standard MLFB for quick delivery RT cable selection chart RT cable codes for length and type able length m (ft) Standard (teflon wrapped) ( F) Order code 6 (20) R01 2) R21 15 (50) R02 2) R22 30 (100) R03 2) R23 6 (150) R0 R2 61 (200) R05 R25 91 (300) R06 R26 Insert 1) ( F) 1) Submersible RT cable is not available for portable versions. 2) Standard MLFB for quick delivery Siemens FI /333
17 Flow Measurement HV heck metering kit Overview Siemens G 2011 pplication The SITRNS FU1010 heck Metering Kit is a highly accurate clamp-on non-intrusive ultrasonic flow display transmitter or revenue grade thermal energy sub-metering and energy efficiency distribution monitoring, with a real time coefficient of performance (OP) for HV systems. This kit is ideal for applications which include: hilled water sub-metering ondenser water Potable water mmonia and glycol River and lake water Lake source cooling The SITRNS FU1010 dual channel clamp-on check metering kit is an all inclusive HV chilled water kit developed especially for verifying the accuracy and performance of any brand or type of flowmeter. The meter's portability makes it capable of verifying the performance of meters based on any existing flow measurement principle: electromagnetic, vortex, insertion turbine, or ultrasonic. Perfect for areas where no metering exists. Ideal for balancing building performance. It accurately computes flow over an extremely wide range and measures practically all conductive or non-conductive clean or moderately aerated liquids or liquids with suspended solids. ual channel models can measure two separate applications at the same time. Benefits Performance check or verification of any type or brand of flowmeter Measures energy rate and total consumption with highest accuracy available ccurately measures at both low flow rates and low differential temperatures Field use is facilitated by meter portability charge for hours of normal operation 1 MByte datalogger capability downloadable to P via included RS232 cable Performs fast, easy and cost-efficient on-site measurement of any convoluted pipe from 25. mm to 9.1 m (1.0" to 360") elivered as an all inclusive kit with all the equipment needed to conduct performance and verification tests (cables, multiple sensors, flow transmitter etc.) omes in a sturdy rolling case with a telescope handle that holds all the equipment needed to conduct performance and verification tests. esign IP0 (NM 1) Impact resistant enclosure, constructed of flame retardant BS with polycarbonate display and polyester keypad ual channel/dual path Function Integral 33 button keypad and large (128 x 20 pixel) graphic display visible up to 12 m (0 ft) away -wire 1000 Ω platinum RT's for supply and return temperature measurements are precision matched to within 0.01 (0.02 F) hiller efficiency analysis: accepts an independent analog input representing kw usage for calculation of the following functions which can be selected for data logging or output purposes: - ooling load (kw/ton) - oefficient of performance (OP) - nergy efficiency ratio (R) Temperature is factory calibrated with built-in field calibrator Built-in energy/btu mode etection of aeration and cavitation caused by worn or damaged impellers, misaligned shafts, etc. urrent, voltage, frequency and RS232 outputs (see specification section for details) Optional current, voltage and temperature inputs (see specification section for details) ZeroMatic Path automatically sets zero Bi-directional flow operation 1 MByte data logger with both site and data logger storage nglish, Spanish, German, Italian and French language options /33 Siemens FI
18 Siemens G 2011 Flow Measurement heck metering kit Technical specifications Pipe sizes 25. mm to 9.1 m ( ) ccuracy ± 0.5 %... ± 2.0 % of flow rate Flow range 12 m/s (0 ft/s) bidirectional Media temperature ( F) nclosure ratings IP0 (NM 1) impact resistant See page /327 for complete technical specifications erificates and approvals Portable enclosures Unclassified locations lassified locations UL ULc M irective 200/108/ TX irective 9/9/ Selection and Ordering data nergy check metering kit ontent of delivery 1 ual channel portable submersible flow transmitter 1 pair Universal sensors 3 1 pair oppler sensors 1 pair High precision sensors 2 1 pair High precision sensors 1 2 pairs RTs 2 pairs Mounting zclamp ( mounting zclamp chains) 1 Battery charger 2 pairs 6 m (20 ft) sensor cables 1 RS232 cable RT cable 6 m (20 ft) Mountings for RTs 1 Spacer bar (Portable) 2 F connector to BN 1 Flow case 1 Flow meter manual 1 Laminated card set 1 ertificate of intrinsic calibration ) Subject to export regulations L: N, N: R99H. Order No. ) QO:FUHVKIT Siemens FI /335
Flow Measurement. SITRANS F US Clamp-on. SITRANS FUP1010 (Portable) 4/318 Siemens FI Overview
Flow Measurement SITRNS F US lamp-on Siemens G 2011 Overview SITRNS FUP1010 clamp-on non-intrusive ultrasonic flow transmitter offers maximum versatility plus battery power for portable field use. It can
More informationFlow Measurement SITRANS F US Clamp-on
Siemens G 2017 SITRS US lamp-on Overview SITRS U1010 clamp-on non-intrusive ultrasonic flow transmitter offers maximum versatility plus battery power for portable field use. It can operate in either Wideeam
More informationFlow Measurement. SITRANS F US Clamp-on. SITRANS FUP1010 (Portable) 4/318 Siemens FI Overview
Flow Measurement Siemens AG 2011 Overview SITRANS FUP1010 clamp-on non-intrusive ultrasonic flow transmitter offers maximum versatility plus battery power for portable field use. It can operate in either
More informationFlow Measurement. SITRANS F US Clamp-on. SITRANS FUE1010 (Energy) 4/326 Siemens FI Overview
Flow Measurement Siemens AG 2011 Overview Application SITRANS FUE1010 is ideally suited to thermal energy / power industry applications, including: Chilled water sub-metering Hot water sub-metering Condenser
More informationSiemens AG Pulse, relay output. Input Flow range. Digital Inputs. Output. Pulse rate 1) Accuracy. Batch repeatability ± 0.
Flow Measurement Siemens AG 2011 SITRANS FST020 (Basic) Overview SITRANS FST020 offers reliable flow measurement at a much lower cost than other clamp-on ultrasonic flowmeters, with flow rate accuracy
More informationFlow Measurement. SITRANS F US Clamp-on. Accessories/Spare parts. 4/354 Siemens FI Accessories/Spare parts for clamp-on ultrasonic flowmeters
Flow Measurement Siemens AG 2010 for clamp-on ultrasonic flowmeters Universal Portable Sensors Selected generally for portable systems where a wide variety of pipes are to be measured. Since they are selected
More informationSITRANS F US Clamp-on
Siemens AG 2011 Flow Measurement for clamp-on ultrasonic flowmeters Universal Portable Sensors D) 7ME3951-... Selected generally for portable systems where a wide variety of pipes are to be measured. Since
More informationSITRANS F flowmeters SITRANS F US. SITRANS FUT1010 Ultrasonic flowmeter. Overview. Application
Overview SITRANS F flowmeters Application Liquid applications Gas applications Pipelines Custody transfer, allocation, Upstream Production wells, line balance, gathering, separation interface/densitometer
More informationFlow Measurement SITRANS F US Clamp-on
for clamp-on ultrasonic flowmeters Description Description Universal Portable Sensors Selected generally for portable systems where a wide variety of pipes are to be measured. Since they are selected based
More informationFlow Measurement SITRANS F S Clamp-on
Function Operating Principle The SITRANS F S system is a transit-time ultrasonic meter that provides exceptional performance using a non-intrusive clampon approach. Ultrasonic sensors transmit and receive
More informationPortable Transit Time Flow Meter for Accurate Flow Measurement from Outside a Pipe
Portable Transit Time Flow Meter for Accurate Flow Measurement from Outside a Pipe Portable Ultrasonic Flowmeters Models PT400 & PT500 Measure Flow of Clean Fluids in Full Pipes with Non-contacting Ultrasonic
More informationPortable Ultrasonic Flow Measuring System prosonic flow 92
Technical Information TI 060D/24/ae Portable Ultrasonic Flow Measuring System prosonic flow 92 Temporary volume flow measurement of liquids with Clamp On sensors Features and benefits Portable transmitter,
More informationRange of Ultrasonic Flowmeters.
Range of Ultrasonic Flowmeters www.adeptfluidyne.com Ultrasonic Flowmeter Series 6700 Working Principle The Transit Time Flowmeter utilises two transducers that function as both, ultrasonic transmitters
More informationLevel Measurement Point level measurement - Vibrating switches
Siemens G 2018 SITRNS LVS200 Overview SITRNS LVS200 is a vibrating point level switch for high, low, or demand level detection of bulk solids. enefits High resistance to mechanical forces Strong vibration
More informationHTTF Transit Time Ultrasonic Flow Meter
Installation onsiderations imensional Specifications 1. Select the optimum mounting location on the piping system a full pipe with at least 10 straight pipe diameters upstream and 5 pipe diameters downstream
More informationTurbidity and Suspended Solids Transmitter
Data Sheet 5.1 We reserve the right to continuously improve our products and make any change in the stated specifications and dimensions without prior notice. DK: NO: SE: NL: USA: AUS: +45 45 56 06 56
More informationElectromagnetic Flowmeters. Product Overview.
Electromagnetic Flowmeters Product Overview www.lcmeter.com Premier products, premier performance Liquid Controls offers a broad selection of electromagnetic (Mag) flow meters for industrial and water
More informationSeries TFXL ULTRASONIC CLAMP-ON FLOW METER DIMENSIONAL SPECIFICATIONS PRODUCT INSTALLATION
Series PROUT INSTLLTION Series IMENSIONL SPEIFITIONS MEHNIL IMENSIONS: INHES (MM) Installation onsiderations 1. Select the optimum mounting location on the piping system a full pipe with at least 10 straight
More informationtekson TS Series Low Cost Ultrasonic Water Energy Flow Measurement
Sensing the pulse of industry tekson TS Series Low Cost Ultrasonic Water Energy Flow Measurement tekflo sensors are proud to present their tekson TS Series ultrasonic water energy meter, which uniquely
More informationSITRANS F flowmeters SITRANS F US SITRANS FUS880. 4/196 Siemens FI Overview
SITRNS F flowmeters Overview pplication Irrigation systems Irrigation distribution systems Pumping stations Canal laterals On-farm outlets Water well production rip and sprinkler irrigation Center pivot
More informationMarsh McBirney Flo-Dar
Marsh McBirney Flo-Dar Accurate Flow Measurement Flo-Dar TM provides the user with highly accurate flow measurements under a wide range of flows and site conditions. By measuring the velocity of the fluid
More informationSpiraflo Steam flowmeters
Spiraflo Steam flowmeters Using a Spiraflo steam meter from Spirax Sarco will enable you to measure steam use accurately under all load conditions. It will provide vital information on usage and associated
More informationAppendix. Clearance. Skewed profiles. Application Schematics
Appendix Application Schematics The purpose of the application schematics is to show different applications and the best sensor location for a particular application. Clearance Because the sensor will
More informationElectromagnetic amplifier type ModMAG M10 for all detectors
Badger Meter Europa GmbH Nürtinger Str. 76 72639 Neuffen (Germany) Tel. +49-7025-9208-0 Fax +49-7025-9208-15 www.badgermeter.de badger@badgermeter.de Electromagnetic amplifier type ModMG M10 for all detectors
More informationTRANSIT TIME FLOW METERS
TRANSIT TIME FLOW METERS TTFM100-F1-NG TTFM100-F2000-NG TTFM100-B-HH-NG TTFM100-F18-NG TTFM200-F3-NG TT100/8812NG RAFALLO PERCALIN CORPORATION Unit 10 MSA Prime Center, Prime St., Madrigal Business Park
More informationUltrasonic Flowmeters
Ultrasonic Flowmeters For Liquids and for Air From Air to Oil Reliable Flow Measurement 21A1-E-0006a Innovative Solutions for Various Applications Spool Piece Ultrasonic Flowmeter for Liquids High accuracy:
More informationFlow Measurement SITRANS F M. Flow sensor MAG 5100 W. 4/68 Siemens FI Overview
Flow Measurement Siemens G 2010 Overview pplication The main applications of the electromagnetic flow sensors can be found in the following fields: Water abstraction Water treatment Water distribution
More informationFCI ST50 Series Flowmeters Low Cost, Low Maintenance Air, Compressed Air and Nitrogen Flow Measurement for Process and Plant Applications
FCI ST50 Series Flowmeters Low Cost, Low Maintenance ir, Compressed ir and Nitrogen Flow Measurement for Process and Plant pplications Wastewater Treatment eration Control lower and Dryer ir Flow Control
More informationThe readings you need, right where you need them. AX Series Vortex Meters
The readings you need, right where you need them. AX Series Vortex Meters Multivariable function from a single meter Vortex multivariable meters from Azbil North America employ three sensing elements in
More informationEGM1100C MAGMAX. Compact Electromagnetic Flowmeter GENERAL FEATURES STANDARD SPECIFICATION. General Specification
EGMC Compact Electromagnetic Flowmeter GENERA MAGMAX EGMC is the compact type electromagnetic flowmeter with a converter EGC mounted integrally on a primary head EGS lined with fluorocarbon resin PFA.
More informationF-1500 SERIES INSERTION TURBINE FLOW METER FEATURES Belcher Road South, Largo, FL USA Tel +1 (727) Fax +1 (727)
F-1500 SERIES INSERTION TURBINE FLOW METER Insertion turbine flow meters are ideal for use in larger steam lines where downsizing the line size to improve flow measurement is not desirable. In these applications,
More informationIsoil Industria a worldwide supplier of electromagnetic flowmeters Total flow control. Accurate to the drop.
www.isomag.eu Isoil Industria a worldwide supplier of electromagnetic flowmeters Total flow control. Accurate to the drop. 1 THE IDEAL FLOWMETERS FOR ANY APPLICATION from DN03 to DN2400 wide range of process
More informationUTM10 Series Ultrasonic Transit-time Flowmeters
Page 1 of 5 TI-P197-01 MI Issue 1 UTM10 Series Ultrasonic Transit-time Flowmeters Description UTM10 ultrasonic flow and energy meters clamp onto the outside of pipes and do not make contact with the internal
More informationFlow Measurement SITRANS F M
Overview The electromagnetic sensor MAG 1100 F is designed to meet applications in the food and beverage industry. Benefits sizes: 10 to 100 (/8 to 4 ) AISI 16 stainless steel enclosure : Hygienic connection,
More informationUFM 800 W, C and UFM 800 W Hot Tapping. Ultrasonic flowmeters. for water and wastewater
KROHNE 12/2006 7.02343.22.00 MAR UFM 800 W, C and UFM 800 W Hot Tapping Ultrasonic flowmeter for water and wastewater...with weld-in sensors for metal pipelines...with built-on or built-in sensors for
More informationDYNAMETERS SERIES DMTF ULTRASONIC FLOW METER
DYNAMETERS SERIES DMTF ULTRASONIC FLOW METER Advanced Clamp-on Transit-time Ultrasonic Flow meter for Accurate Flow Measurement Features: Cost effective and versatile High accuracy, better than ±1.0% read
More informationLevel Measurement Point level measurement - Rotation paddle switches
Siemens 017 SITRNS LPS00 Overview SITRNS LPS00 is a rotary paddle switch for point level and material detection in bulk solids. enefits Proven paddle switch technology for bulk solids High integrity mechanical
More informationSITRANS FX300 4/289. System Overview. Overview
Siemens G 2008 SITRNS F flowmeters Overview System Overview Version Single transmitter Dual transmitter Options Standard Pressure sensor Flange Pressure sensor and isola- Standard tion valve Sandwich vortex
More informationLevel Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. 5/16 Siemens FI Overview.
Level Measurement Pointek LS200 Standard Siemens A 20 Overview onfiguration Installation Pointek LS200 (standard version) is a versatile inverse frequency shift capacitance level switch with optional rod/cable
More informationDSL-240 MkIII Single Pass Dust Monitor Measures mg/m 3 using DDP
Ideal for monitoring dust levels in the exhaust gas of industrial combustion or air filtration processes. Innovative Dynamic Detection Principle (DDP) measurement technique Immune to gradual reductions
More informationDSL-220 MkIII Single Pass Opacity Monitor Measures 0-100% Opacity
Ideal for monitoring opacity and smoke levels in the exhaust gas of industrial combustion or air filtration processes. In situ measurement directly in exhaust gas flow using the widely accepted light transmission
More informationThe readings you need, right where you need them. AX Series Vortex Meters
The readings you need, right where you need them. AX Series Vortex Meters Multivariable function from a single meter Principles of Operation Vortex multivariable meters from Azbil North America employ
More informationMODEL 106F TEFLON LIQUID FLOW SENSOR
TEFLON LIQUID FLOW SENSOR [ Advanced microturbine design for repeatable results - with no particle shedding & no zero drift [ Compatible with solvents, deionized water, acids, CMP slurries, etc. [ Extremely
More informationElectronic Temperature Sensor
Connection Head Type RTD or Element or RTD Cast Aluminum, Polypropylene or Stainless Steel Head Weather Proof Welded or Spring Loaded TDD TMD Hot Junction: Head Process Connection Conduit Connection 100Ω
More informationThermoPro TM Series TP10
MEASURE TODAY. ENSURE TOMORROW. ThermoPro TM Series TP10 Applications The TP10 thermal energy measurement meter is an ideal choice for a wide range of applications in HVAC, energy production, energy transfer,
More informationLevel Measurement Continuous level measurement Ultrasonic transmitters
Siemens AG 2018 Overview Configuration ultrasonic level transmitter, ideal for level, volume, and volume flow measurements. It works with liquids, slurries, and bulk materials up to 12 m (0 ft). Benefits
More informationWaterMAG. Electromagnetic Flowmeter for Water Applications. Model MCB10A OVERVIEW APPLICATIONS FEATURES. No. SS2-MCB
WaterMAG Electromagnetic Flowmeter for Water Applications OVERVIEW The WaterMAG is an electromagnetic flowmeter for water measurement applications based on field proven Azbil Corporation's technologies.
More informationNC State University Design and Construction Guidelines Division 23 Energy Management
1.1 Purpose A. The following guidelines provide the methodology and requirements to assure that designs meet NC State standards for campus utility metering. 2.1 General Requirements A. Meters shall have
More informationPrinciple of Operation
Turbine Flow Meters Flow Technology Turbine Flow meters are commonly used in mission critical applications demanding superior accuracy, quality and reliability. Ideal for clean liquids and gases, such
More informationFIELD DEVICES - FLOW PSS 1-6F9 A. Product Specifications
FIELD DEVICES - FLOW Product Specifications Logo 9100A Series Magnetic Flowtubes with Ebonite Liners 1 to 78 in (25 to 2000 mm) Nominal Flowtube Sizes The Foxboro brand 9100A Series Magnetic Flowtube together
More informationOnline data sheet FLOWSIC100 VOLUME FLOW MEASURING DEVICES
Online data sheet FLOWSIC100 VOLUME FLOW MESURING DEVICES VOLUME FLOW MESURING DEVICES B C D E F H I J K L M N O P Q R S T 15267 14181 certified certified Ordering information Type FLOWSIC100 Part no.
More informationSMARTLINK METER. Digital Self-checking Thermal Mass Flow Meter
Flow Control Components - SMARTLINK METER 10-30.9-1 SMARTLINK METER Digital Self-checking Thermal Mass Flow Meter Precise, repeatable mass flow measurement for fuel, air and combustion streams Displays
More informationFlow Measurement SITRANS F C. Flow sensor MASS 2100 DI 3 to DI 40. 4/180 Siemens FI
Siemens AG Flow sensor MASS DI 3 to DI 0 Overview MASS DI 3 to DI 0 is suitable for accurate mass flow measurement of a variety of liquids and gases. The sensor offers superior performance in terms of
More informationF-2600 SERIES INLINE VORTEX FLOW METER
F-2600 SERIES INLINE VORTEX FLOW METER APPLICATIONS Saturated steam Hot water to 500 F (260 C) standard 750 F (400 C) optional Applications with optional pressure sensor Superheated steam to 500 F (260
More informationSignet 2551 Magmeter Flow Sensor
Signet 2551 Magmeter Flow Sensor Available in a variety of wetted materials and ideal for pipe sizes up to DN900 (36 in.) Features Test certificate included for -X0, -X1 Patented Magmeter technology No
More informationKROHNE 10/ Optimass 70 & 71 Single Tube Coriolis Mass Flowmeters for the Chemical Industry
KROHNE 10/02 7.02443.21.00 GR Optimass 70 & 71 Single Tube Coriolis Mass Flowmeters for the Chemical Industry Optimass One Tube... Optimass is a brand new family of Coriolis mass flowmeters from KROHNE.
More informationDissolved Oxygen Measurement System with Air Blast Cleaner
Product Data Sheet PDS 71-DO-03/04/rev.D August 2004 MODEL DO -03/-04 Dissolved Oxygen Measurement System with Air Blast Cleaner COMPLETE SYSTEM INCLUDES sensor, analyzer, sensor washer head, mounting
More informationSuperstatic 440. Static Heat Meter, Static Cooling Meter. Application
Superstatic 440 Static Heat Meter, Static Cooling Meter Application Design The Superstatic 440 is a static heat or cooling meter according to standard EN1434 class 2 based on the fluid oscillation principle,
More informationF-1500 SERIES INSERTION TURBINE FLOW METER
F-1500 SERIES INSERTION TURBINE FLOW METER APPLICATIONS Saturated steam Hot water to 450 F (232 C) standard 850 F (454 C) optional Applications with optional pressure sensor Superheated steam to 450 F
More informationMobrey MSM400 Ultrasonic sludge density measurement system
Technical specification sheet IP257 October 2008 Mobrey MSM400 Ultrasonic sludge density measurement system Level Features Measuring range up to 50% solids Simple keypad operation HMI menu based programming
More informationBattery-Powered Flow Transmitter
Data Sheet SS/AMAS/E Issue 3 Battery-Powered Flow Transmitter AquaMaster Explorer Widest flow range, highest accuracy measures minimal night and peak day flows Optional integral multi-speed, multichannel,
More informationFlow Measurement SITRANS F M. Flow sensor MAG 1100 F 4/57
Overview Integration The complete flowmeter consists of a sensor and an associated transmitter MAG 5000, 6000 and 6000 I. The flexible communication concept USM II simplifies integration and update to
More informationSITRANS F flowmeters SITRANS F C
SITRNS F flowmeters Siemens G 2008 Overview is available as a standard version (DN 50 to DN 150 (2 to 6 )) and a hygienic, EHEDG certified version (DN 20 to DN 80 (¾ to 3 )). MC2 and MC2 hygienic are suitable
More informationSITRANS F M. Flow sensor MAG 1100 F 3/59
Overview Integration The complete flowmeter consists of a sensor and an associated transmitter MAG 5000, 6000 and 6000 I. The flexible communication concept USM II simplifies integration and update to
More informationFlow Measurement SITRANS F M
Overview The electromagnetic sensor MAG 1100 F is designed to meet applications in the food and beverage industry. Benefits sizes: 10 to 100 (/8 to 4 ) AISI 16 stainless steel enclosure : Hygienic connection,
More informationF6125HD, 5, 2-Way Butterfly Valve Resilient Seat, 304 Stainless Steel Disc
6125H, 5, 2-Way utterfly Valve Resilient Seat, 304 Stainless Steel isc pplication Valve is designed for use in NSI flanged piping systems to meet the needs of bi-directional high flow HV hydronic applications
More informationPressure Transmitter
FCO318 Differential Pressure Transmitter Accuracy 0.25% of reading Ultra low pressure measurement Wide span adjustment 2-wire ma, 3-wire or 4-wire voltage output Two configurable relays and bi-colour LED
More informationSuperstatic 440. Static Heat- and Cooling Meter. Application
Superstatic 440 Static Heat- and Cooling Meter Application Design The Superstatic 440 is a static heat- and cooling meter according to standard EN1434 class 2 based on the fluid oscillation principle,
More informationSITRANS F flowmeters SITRANS F C MASSFLO MASS MC1. 4/146 Siemens FI Overview
Overview MSS 2100 MC1 DN 50 to DN 150 (2 to 6 ) is suitable for accurate mass flow measurement for all kind of liquids and gases. The sensor offers superior performance in terms of flow accuracy, turn-down
More informationSMARTLINK METER. Digital Self-checking Thermal Mass Flow Meter
Flow Control Components - SMARTLINK METER 10-30.9-1 SMARTLINK METER Digital Self-checking Thermal Mass Flow Meter Precise, repeatable mass flow measurement for fuel, air and combustion streams Displays
More informationMEASURE TODAY. ENSURE TOMORROW. SpireMag Series T-MAG Electromagnetic BTU Meter
MEASURE TODAY. ENSURE TOMORROW. SpireMag Series T-MAG Features The T-MAG BTU meter is the latest addition to the SpireMag series for accurate thermal energy measurement. It utilizes a high accuracy electromagnetic
More informationF6700 ELECTROMAGNETIC METER
EETROMAGNETI FOW TRANSMITTER Special Features: F6700 Full Bore type Simple and ost effective onstruction Absolutely Maintenance free Suitable for all conductive liquids and slurries Outstanding Accuracy
More informationProduct Data Sheet. Flow Monitor. B2800 Series DESCRIPTION OPERATION FEATURES
Flow Monitor 2800 Series SRIPTION The 2800 flow monitor is designed to be comprehensive, user-friendly, flexible and cost efficient. This microprocessor-based display comes pre-calibrated when purchased
More informationF6100HD, 4, 2-Way Butterfly Valve Resilient Seat, 304 Stainless Steel Disc
6100H, 4, 2-Way utterfly Valve Resilient Seat, 304 Stainless Steel isc pplication Valve is designed for use in NSI flanged piping systems to meet the needs of bi-directional high flow HV hydronic applications
More informationF-2700 SERIES INSERTION VORTEX FLOW METER
F-2700 SERIES INSERTION VORTEX FLOW METER CALIBRATION Every ONICON flow meter is wet calibrated in a flow laboratory against standards that are directly traceable to N.I.S.T. A certificate of calibration
More informationVantage 6000 Portable Ultrasonic Flow Meter
Vantage 6000 Portable Ultrasonic Flow Meter Instruction Manual Eastech Badger Flow Technology Group 4250 S. 76 th East Ave. Tulsa OK 74145 800-226-3569 Description The Vantage 6000 portable transit time
More informationFor reliable control of small, large or multi-system-type lubrication systems
LMC 301 controller For reliable control of small, large or multi-system-type lubrication systems Models 86500, 86501 Models 86502, 86503 Designed for use with pumps that have no internal controller, the
More informationLMC 301 controller. For reliable control of small, large or multi-system-type lubrication systems
LMC 301 controller For reliable control of small, large or multi-system-type lubrication systems LMC 301-controlled systems can be configured to verify that lubricant is dispensed LMC 301 controller with
More informationHand held ultrasonic flow meter
Hand held ultrasonic flow meter TDS-100H hand held ultrasonic flow meter is a battery power ultrasonic flow meter,the capability of a full size flow meter. it is carefully designed for portability and
More informationElectromagnetic amplifier Primo Advanced for all detectors
Electromagnetic amplifier Primo dvanced for all detectors Features ccuracy ±0,25% Flow range 0,03 12 m/s 6 2000 LC display Power supply 85 2 VC / 24 VC escription imensions The amplifier type Primo dvanced
More informationLower maintenance costs: with no moving parts, there is nothing on the DFX to wear down. Wide measuring range: 0.15 to 30 FPS (0.05 to 9 MPS).
PRODUCT APPLICATIONS / APPLICATION QUALIFICATION DIMENSIONAL SPECIFICATIONS MECHANICAL DIMENSIONS: INCHES (mm) DOPPLER ULTRASONIC FLOW METER Carbonated liquids Mining slurry Drilling mud Coal-seam water
More informationFLOW METER ULTRASONIC-VOLTEX FLOW METER ASUSV SERIES IMPELLER FLOW METER ASIP80 SERIES IMPELLER FLOW METER ASSPX SERIES
FLOW METER P.193 P.195 P.196 P.197 P.198 P.198 P.198 P.199 P.199 P.200 P.200 P.200 P.200 ULTRASONIC-VOLTEX FLOW METER ASUSV SERIES IMPELLER FLOW METER ASIP80 SERIES IMPELLER FLOW METER ASSPX SERIES INSERTION
More informationFH8500. Metering Solution for Custody Transfer Applications. One Step Ahead in Ultrasonic Flowmetering. Main Applications
FH85 Metering Solution for Custody Transfer Applications One Step Ahead in Ultrasonic Flowmetering Main Applications Oil Production & Allocation FSO, FPSO Metering Tanker Off-loading Storage Management
More informationDetector (for water measurement applications)
WaterMAG Smart Electromagnetic Flowmeter Detector (for water measurement applications) Model MGW18 OVERVIEW The WaterMAG electromagnetic flowmeter detector is a high performance, highly reliable flowmeter
More informationYour Global Source for Today s Most Popular Solenoid Valves
lcon Solenoid Valves Your Global Source for Today s Most Popular Solenoid Valves lcon Solenoid Valves Your Global Source for Today s Most Popular Solenoid Valves lcon Solenoid Valves, a division of International
More informationElectromagnetic flowmeters Series FLOMAT Insertion electromagnetic flowmeter for conductive liquids
Electromagnetic flowmeters Series FLOMAT Insertion electromagnetic flowmeter for conductive liquids For use in large diameter pipes as an economical solution for flow measurement Flow rate measurement
More informationGeneral Specifications
eneral Specifications Model TB Surface Scattering Light Meter S 12E04A02-01E eneral There have been increasing demands for both industrial use and portable water of good quality because of rapid industrial
More informationTECHNICAL SPECIFICATIONS. Measuring Accuracy ±2% of full scale. Repeatability ±0.5% of full scale
TECHNICAL SPECIFICATIONS Measuring Accuracy ±2% of full scale Repeatability ±0.5% of full scale Flow Measuring Range 1/2 porting: 0.5 15 GPM (2 60 LPM) 3/4 1 porting: 1.5 50 GPM (60 200 LPM) Turn Down
More informationFLOWMETERS PRODUCT OVERVIEW
FLOWMETERS PRODUCT OVERVIEW 2018 QSE MAG METER Non-Intrusive (No moving parts) Electromagnetic Flow Meter ELECTROMAGNETIC Turf / Irrigation Agriculture Irrigation Turf Irrigation Systems Micro Irrigation
More informationTime Delta S Fixed Transit-Time Flow Meter System
Fixed Transit-Time Flow Meter System Key Features Dynamic flow correction Simple configuration Digital outputs Enhanced anti-bubble measurement technology (ABM) Rugged and reliable Maintenance free The
More informationModel Q45H/ Residual Chlorine Monitor...
Model Q45H/62-63 Residual Chlorine Monitor... ATI s Model Q45H is designed for on-line monitoring and control of chlorination systems. It is available in two versions: a free chlorine monitor for drinking
More informationExtreme Environment For high pressure, low temperature, and high temperature applications
SENSOR DATA SHEET Extreme Environment For high pressure, low temperature, and high temperature applications 800-552-6267 kamansensors.com measuring@kaman.com Features v For applications requiring high
More informationF-2700 SERIES INSERTION VORTEX FLOW METER
F-2700 SERIES INSERTION VORTEX FLOW METER APPLICATIONS Saturated steam Hot water to 500 F (260 C) standard 750 F (400 C) optional Applications with optional pressure sensor Superheated steam to 500 F (260
More informationAdvanced Force / Torque Indicator
32-1128 Advanced Force / Torque Indicator The 5i advanced digital force / torque indicator is designed to work with a wide range of Mark-10 remote force and torque sensors (see page 3). With exclusive
More informationInsertion Flow Meters. Municipal Market Customer Presentation
Insertion Flow Meters Municipal Market Customer Presentation Topics for Discussion Product Description Product Offering Product Name Principal of Operation Why the New FPI Mag? Development Team Comparison
More informationOptidew Vision Optical Dew-Point Meter
Optidew Vision Optical Dew-Point Meter Chilled Mirror Instruments A precision hygrometer, combining drift free measurement with the flexibility of a remote sensor. Ideal for laboratory and industrial measurements,
More informationF-2600 SERIES INLINE VORTEX FLOW METER
F-2600 SERIES ININE VORTEX FOW METER APPICATIONS Saturated steam Hot water to 500 F (260 C) standard 750 F (400 C) optional Applications with optional pressure sensor Superheated steam to 500 F (260 C)
More informationHENRI Flowmeter for Pulp Slurry
MagneW 3000 PLUS Smart Electromagnetic Flowmeter HENRI Flowmeter for Pulp Slurry Model MGH14 (onverter) / MGH18 (Detector) OVERVIEW The MagneW 3000 PLUS HENRI (High-Energy Noise-Resistant Instrument) flowmeter
More informationModel DFX Doppler ultrasonic flow meter
Badger Meter Europa GmbH Nürtinger Str. 76 72639 Neuffen (Germany) Tel. +49-7025-9208-0 Fax +49-7025-9208-15 www.badgermeter.de badger@badgermeter.de Model DFX Doppler ultrasonic flow meter Features Badger
More informationFlow Measurement SITRANS F C
Flow sensor SITRNS FCS200 Overview Function The flow measuring principle is based on the Coriolis effect. See "System information ". Integration The complete flowmeter consists of the sensor (SITRNS FCS200)
More information