1 Data Sheet SS/AMAS/E Issue 3 Battery-Powered Flow Transmitter AquaMaster Explorer Widest flow range, highest accuracy measures minimal night and peak day flows Optional integral multi-speed, multichannel, dual-variable logger high precision, high resolution datalogging Sealed for life transmitter all input/outputs via external IP8 plug-and-socket connections Battery operation via external battery pack typically -year life which can be extended even further no power supply required, facilitates installation in remote locations Logged data transmitted via SMS text message facilitates automated handling of logged data from a network of flow meters Automated reporting using SMS text messaging via internal GSM mobile phone Scanreader encoder output fitted as standard (not available on logging versions) Backward-compatible comprehensive range of adaptors for connection to existing AquaMaster sensors AquaMaster Battery-Powered Transmitter combining long battery life with submersibility and easy interconnection as standard
2 Transmitter Comprehensive display Sealed for life - submersible for use in flooded chambers IP8 (NEMA) Resettable or secure totals 8mm high displays for totals (exceeds ISO 44 requirements) Total security: Two user-security levels All connections via Plug & Socket Three outputs (forward & reverse pulse, or pulses & direction and alarm) The AquaMaster Explorer is a new design of battery-powered transmitter for the AquaMaster range of flowmeters. It has a stainless steel housing with a thermoplastic outer and the assembly is sealed-for-life to IP8 as standard. The unit incorporates plug & socket connections for all inputs and outputs. In addition it derives its power from a similarly-sealed external battery pack which provides an extended battery life of typically years, which can be further extended at the cost of a slight deterioration in system performance. The transmitter can be mounted directly onto the AquaMaster sensor or remotely from it. This new design continues to provide the water industry with the most comprehensive range of flow data and information currently available. If all the data is not required, the unit can be configured so that only the required values are displayed, thus ensuring simple reading with no superfluous data. For integrally-mounted units, a new mounting system positions the display such that it is visible from both the top and the side. The AquaMaster s program memory or firmware uses reprogrammable Flash memory technology which has been enhanced to allow this firmware to be upgraded in the field (integral data logger versions only), via a local serial port connection or via GSM, if fitted. This future-proofs AquaMaster, making enhancements or new features available to installed units. Remote Access via Mobile Phone Technology Remote access to logger data over GSM network by SMS text message Remote configuration, status monitoring and preventive maintenance Diagnostics and configuration, via standard GSM mobile phone Automated reporting of metering data via SMS text SMS data accessible via industry-standard SMS Gateways capable of exporting data using Windows DDE, OLE, XML etc. Allows remote software upgrades/enhancements by ABB Fit and Flow No need to match sensor and Transmitter Fast, reliable operation Foolproof, no errors Sensor stores all calibration factors, site setting numbers etc. Volume totalizer and tariff values backed-up every minutes in sensor for total security Multiple, programmable password levels stored for measurement security Standard Tariff Setting AquaMaster incorporates a multiple tariff feature where the accumulated flow volume is routed to one of two 8-digit signed tariffs (tariff A and tariff B), depending on time and date. It is fully programmable by the user for time of day, day of week or date during the year. These user-defined times/dates can be combined in a variety of modes as illustrated in the tables below to produce a variety of tariff regimes. Weekly Cycle Defined Mode Tariff A Tariff B Day time during weekend Yearly Cycle Defined Night time at weekend + day and night during week Day time during week Night time during week + day and night during weekend 3 All day times All night times 4 Night time during weekend Day and night during weekend Day time during weekend + night time during weekend All day times + night time during weekend Day time during weekend + day and night during week Day and night during week Night time during week + day time during weekend Night time during week Mode Tariff A Tariff B Day time during summer Night time during summer + day and night during winter Day time during winter Night time during winter + day and night during summer 3 All day times All night times 4 Night time during summer Day and night during summer Day time during winter + night time during summer All day times + night time during summer Day time during summer + day and night during winter Day and night during winter Night time during winter + day time during summer Night time during winter
3 Easy, Low Cost Installation No matter what the location or installation requirements, AquaMaster provides a cost-effective solution. Both the sensor and the transmitter can be fully submersible, enabling installation in flooded chambers. In addition, the sensor is buriable, thus eliminating the need for a chamber. Installation merely involves excavating to the pipeline, fitting the sensor and back filling the hole, to ensure very fast, low cost installation. The associated Transmitter is then located in the most convenient position for the user. The elimination of bypasses and ancillary items such as strainers, enables the installation cost to be kept to an absolute minimum. These factors, together with the innovative Fit and Flow system, ensure foolproof installation with total user confidence. Specification Transmitter Mounting Directly on sensor or Remote up to m ( ft) Housing IP8 (NEMA P) Stainless steel housing in a Thermoplastic outer cover with window, encapsulated with polyurethane-based resin. Electrical connections IP8 plug & socket Sensor cable ABB cable supplied as standard SWA cable available (via adaptor box) on application External battery pack IP8 (NEMA P) Battery to C (3 to F) typically years Extended life is possible to give, say, years with a small degradation in response time and slightly increased measurement uncertainty (contact ABB for details). Battery life is shorter with GSM, depending on how frequently it is used and for what period. For example, used once per day for SMS automated reporting of data logged at minute intervals, the life of a battery pack would be typically reduced to approximately 4 years. Pulse and alarm outputs Three bidirectional solid state switches with common isolation ±3V DC ma Output Forward only, or forward plus reverse pulses Output Reverse pulses, or direction indicator Output 3 Alarm indicates any problem with measurement or with power Pulse output Hz maximum, % nominal duty cycle Serial data communications Local Port RS3 compatible via ABB lead (Option) Encoder Interface (non-logging versions only) Function Remote reading of totalizer and serial no. Protocol ABB encoder Connections -wire for inductive pads (max. cable length 8m) 3-wire for AMR Compatible readers Severn Trent Services Smart reader ABB or Elster SR and SR Logicon Versaprobe Itron ERT Compatible inductive pads Starpad ABB Telemetry applications using remote serial data communications Internal GSM modem Dual Band GSM; fully programmable schedule for battery operation and Automated Meter Reading Pressure System External Transducer Pressure range bar g or bar Abs Connection Standard quick-fit male probe connector via an adapter cable Operating temperature range (ambient) to C ( 4 to 8 F) Caution. Protect the sample and transducer from freezing. Accuracy (typical) ±.4% of range Thermal error band (typically C [ F]) ±.% span Cable length or m ( or 33 ft) Temperature Ranges Process C (8 F) C (4 F) Ambient C (4 F) C ( 4 F) Storage C (8 F) 3 C ( F) 3
4 Logger details (option) Logger Function Default Settings Table Logger 3 Flow & Pressure Flow & Pressure Forward, Reverse, Tariffs & Net Flow Totals No. of Records Logging Interval to s (adjustable) 4 hours (fixed) Typical Capacity 3 ~ min. year Mode Cyclic Cyclic Cyclic Use ABB LogMaster Use Technolog (PMAC) Use Primayer Primeware Use OSI PI Database/ CBV (WADIS) System Response Time (Programmable) Minimum s (battery-powered) Languages English French German Spanish Italian Dutch Other languages can be added via Windows download Program (contact ABB) GSM Antenna (option) Mounting Integral with transmitter or remote. Antenna environmental IP (NEMA4) waterproof for accidental submersion (Note. The GSM does not operate with integral antenna under water). General advice is to mount the antenna as high as possible, always outside of any metal enclosure and not under the surface of the ground. Configuration Parameter Default European Default North American Pulse Factor Pulse Units m 3 Ugal Totalizer Units m 3 Ugal Full Scale Flow ISO 44 Qn ISO 44 Qn Flow Units m 3 /h MUGD Velocity Units m/s ft/s Date Format from Country Code DDMMYY MMDDYY Flow Response Time (s) 3 3 Display Flow Rate Yes Yes Display Forward Total Yes Yes Display Reverse Total Yes Yes Display Net Total No No Display Date No No Display Velocity No No Output Option Pulse Forward Pulses Forward Pulses Forward Output Option Pulse Reverse Pulses Reverse Pulses Reverse Profile Factor Probe Insertion Factor 4
5 Overall Dimensions Dimensions in mm (in.) (4.) Transmitter Mounted on Sensor Dimensions in mm (in.) Ø. (.3) Ø3 (.) (4.) (.8) (.) AquaMaster 3 (.4) 8 (.) (.) Transmitter Mounted Remote from Sensor
6 Dimensions in mm (in.) 33 (3) 3 (.) 4 (.8) Battery pack External Battery Pack Optional GSM Modem Measurement System Processor Optional RS3 Communication Port Pulse/Alarm Circuits Common Display Local Configuration Adaptor Optional Pressure Transducer Part No. WEBC Electrical Connections
7 Ordering Information AquaMaster Electronic Water Meter AM/E X X X X X X X X Power Supply Remote Battery (supplied) B Logger/Protocol None ABB Logger ABB Logger BVS ABB Logger Technolog ABB Logger Primayer ABB SMS Logger 3 4 Comms Options None GSM Integral Antenna GSM Remote Antenna (m [3. ft] cable) Language English German Spanish French Dutch Italian D E F H I Pressure Span None Bar Gauge Bar Abs Pressure Transducer None m (. ft) Cable m (33 ft) Cable Labelling Standard Approval Standard
8 AquaMaster Explorer ABB has Sales & Customer Support expertise in over countries worldwide The Company s policy is one of continuous product improvement and the right is reserved to modify the information contained herein without notice. Printed in UK (4.) ABB SS/AMAS/E Issue 3 ABB Limited Oldends Lane, Stonehouse Gloucestershire GL 3TA UK Tel: +44 ()43 8 Fax: +44 ()43 89 ABB Inc. E. County Line Road Warminster PA 894 USA Tel: + 4 Fax:
AquaMaster S Electronic Water Meter for Water System Management
Technical Specification Electronic Water Meter for Water System Management Integrated water measurement system Combines flow, pressure and data logging in a single unit Built-in multi-speed, multi-channel,
More informationAquaMaster 3 FET200 Electromagnetic flowmeter. The smart solution for remote applications
Data Sheet DS/FET200-EN Rev. D AquaMaster 3 FET200 The smart solution for remote applications Widest flow range, highest accuracy reduced bore version measures minimal night flows and peak day flows full
More informationInsertion-Type Electromagnetic Probe Flowmeter
Data Sheet SS/AQUAP Issue 7 Insertion-Type Electromagnetic Probe Flowmeter AquaProbe Excellent accuracy over wide operating flow range in both forward and reverse flow directions enables accurate measurement
More informationAquaMaster3 Electromagnetic flowmeter
Data sheet supplement DS/FEW221-EN AquaMaster3 Electromagnetic flowmeter The high value, precision solution for remote water metering and irrigation applications Measurement made easy Battery power supply
More informationAquaProbe FEA200 Insertion-type electromagnetic flow sensor with AquaMaster 3 transmitter
Data sheet DS/FEA200 EN AquaProbe FEA200 Insertion-type electromagnetic flow sensor with AquaMaster 3 transmitter Maximum performance, minimum hassle Suitable for permanent or temporary installation total
More informationFICHA TÉCNICA DE PRODUTO
FICHA TÉCNICA DE PRODUTO PRODUCT DATASHEET HMI Automação e Instrumentação, Lda. Rua dos 5 Caminhos, nº 570 4780-382 Santo Tirso PORTUGAL Web: www.hmi.pt Tel. +351 252 850 501 Fax. +351 300 013 487 Email:
More informationMeasurement Products. WaterMaster electromagnetic flowmeter The perfect fit for all water industry applications
Measurement Products WaterMaster electromagnetic flowmeter The perfect fit for all water industry applications WaterMaster The perfect balance of power, performance, flexibility and control from the Masters
More informationAquaMaster3 Electromagnetic flowmeter
Data Sheet DS/FER200/FEF200/FEV200 EN Rev. S AquaMaster3 The high value, precision solution for remote water metering and irrigation applications Measurement made easy Full range of power supply options
More informationABB MEASUREMENT & ANALYTICS DATA SHEET. Series and Katharometer power supply units
ABB MEASUREMENT & ANALYTICS DATA SHEET Series 4234-500 and 4234-600 Katharometer power supply units 2 SE RIE S 4 23 4-500 AN D 4 23 4-600 K ATHAROME TE R POWE R SU PPLY U NITS DS/4 23 4-E N RE V. F Measurement
More informationKatharometer Power Supply Units
Instruction Manual IM/4234600 Rev. D Katharometer Power Supply Units 4234 600 & 4234 601 ABB The Company EN ISO 9001:1994 We are an established world force in the design and manufacture of instrumentation
More informationRange of Ultrasonic Flowmeters.
Range of Ultrasonic Flowmeters www.adeptfluidyne.com Ultrasonic Flowmeter Series 6700 Working Principle The Transit Time Flowmeter utilises two transducers that function as both, ultrasonic transmitters
More informationZMT & ZFG2 Zirconia Oxygen Analyzer Systems. Superior technology and quality from the world leader in oxygen measurement
Data sheet DS/ZMT/LO EN Rev. J ZMT & ZFG Superior technology and quality from the world leader in oxygen measurement Integral reference-air supply option avoids necessity for additional equipment Dual
More informationElectromagnetic Flowmeters
Instruction Manual BOOK 6 Accessories and Spares IM/MM/BK6_6 Electromagnetic Flowmeters MagMaster TM AquaProbe TM AquaMag ABB The Company We are an established world force in the design and manufacture
More informationPortable Transit Time Flow Meter for Accurate Flow Measurement from Outside a Pipe
Portable Transit Time Flow Meter for Accurate Flow Measurement from Outside a Pipe Portable Ultrasonic Flowmeters Models PT400 & PT500 Measure Flow of Clean Fluids in Full Pipes with Non-contacting Ultrasonic
More informationABB MEASUREMENT & ANALYTICS DATA SHEET. AC200 Series Industrial 2-electrode conductivity cells with rapid temperature response
ABB MEASUREMENT & ANALYTICS DATA SHEET AC00 Series Industrial -electrode conductivity cells with rapid temperature response AC00 SE RIE S I N DUST RI AL -ELE C TRODE CONDU C TIV IT Y C E LLS DS/AC CO-E
More informationField IT Actuators & Positioners Rotary Actuators - Rated Torque 100 Nm (80 ft-lbs) PME 120-AI/AN. Rotary Actuators Rated Torque 100 NM (80 ft-lbs)
Data Sheet Field IT Actuators & Positioners Rotary Actuators - Rated Torque 100 Nm (80 ft-lbs) PME 120-AI/AN Electric actuator for continuous duty modulating or pulse input control. Stall proof without
More informationVortex Flowmeter FV4000 (TRIO-WIRL V) Swirl Flowmeter FS4000 (TRIO-WIRL S) For flow rate and volume measurement of liquids, gases and steam
Vortex Flowmeter FV4000 (TRIO-WIRL V) Swirl Flowmeter FS4000 (TRIO-WIRL S) For flow rate and volume measurement of liquids, gases and steam Cost savings due to high accuracy Low investment cost through
More informationHygienicMaster Electromagnetic Flowmeter. The clean choice for hygienic applications. ABB Instrumentation
HygienicMaster Electromagnetic Flowmeter The clean choice for hygienic applications ABB Instrumentation HygienicMaster The perfect balance of power, performance, flexibility and control from The Masters
More informationGame changing soft starters
Agile soft starters Low Voltage Soft Starters Game changing soft starters 17 66 A Fire Mode Agile soft starters Soft Stopping Current is limited during soft stopping and gives greater control against water
More informationField IT Actuators & Positioners. Intelligent Electric Modulating Actuator. Contrac RHD Intelligent Electric Modulating Actuator
Data Sheet Field IT Actuators & Positioners Intelligent Electric Modulating Actuator Contrac RHD 16000 Electric actuator for continuous duty modulating or pulse input control. Stall proof without the need
More informationSITRANS F flowmeters SITRANS F US. SITRANS FUT1010 Ultrasonic flowmeter. Overview. Application
Overview SITRANS F flowmeters Application Liquid applications Gas applications Pipelines Custody transfer, allocation, Upstream Production wells, line balance, gathering, separation interface/densitometer
More informationElectromagnetic Flowmeters. Product Overview.
Electromagnetic Flowmeters Product Overview www.lcmeter.com Premier products, premier performance Liquid Controls offers a broad selection of electromagnetic (Mag) flow meters for industrial and water
More informationABB Instrumentation. Thermal Mass Flowmeter Sensyflow. Intelligent solutions for accurate gas mass flow measurement
Thermal Mass Flowmeter Sensyflow Intelligent solutions for accurate gas mass flow measurement Direct mass flow measurement Robust design No moving parts High measuring accuracy Wide measuring range ABB
More informationSentinel Panametrics Custody Transfer Gas Ultrasonic Flowmeter
GE Measurement & Control Sentinel Panametrics Custody Transfer Gas Ultrasonic Flowmeter Applications The Sentinel flowmeter is a complete ultrasonic flowmeter system for the measurement of natural gas
More informationAP300 Series Combination ph/redox (ORP) Sensors. Measurement made easy. A reliable economic solution for a wide range of applications
Data sheet DS/AP00 EN Rev. F AP00 Series Measurement made easy A reliable economic solution for a wide range of applications Long life large PTFE junction provides resistance to fouling double junction
More informationAC Induction Motor Controller with VCL
Motor Controllers AC Induction Motor Controller with VCL www.curtisinstruments.com 1 The Ultimate Class III Truck Control System: Superb Performance and Value This new AC induction motor controller (inverter)
More informationCallisto 100. Cold Filter Plugging Point Tester
Callisto 100 Cold Filter Plugging Point Tester Cold Filter Plugging Point The Cold Filter Plugging Point (CFPP) method is used to determine the low-temperature operability of diesel fuel, biodiesel, blends
More informationSentinel. Panametrics Custody Transfer Gas Ultrasonic Flowmeter. GE Sensing. Applications. Features
Applications The Sentinel flowmeter is a complete ultrasonic flowmeter system for the measurement of natural gas flow applications such as: Custody transfer Transmission and distribution Underground storage
More informationTechnical Datasheet. Compact DC Energy Meter. Multi-Function DC Energy Meter
Preliminary Datasheet Technical Datasheet Compact DC Energy Meter RISH EM DC series is specially designed to measure, display and communicate DC Voltage, Current, Power and Energy to monitor and control
More informationABB MEASUREMENT & ANALYTICS DATA SHEET Hydrazine monitor
ABB MEASUREMENT & ANALYTICS DATA SHEET 7835 Hydrazine monitor 2 78 35 H YDR AZ I N E MON I TOR DS / 78 3 5-E N RE V. L Measurement made easy Advanced transmitter Auto-ranging with remote range indication
More informationtprime TM Series 280T
MEASURE TODAY. ENSURE TOMORROW. tprime TM Series 280T Applications Residential submetering Commercial buildings District heating / cooling HVAC Green energy management AMR and Billing Features Wear-free.
More informationOptidew Vision Optical Dew-Point Meter
Optidew Vision Optical Dew-Point Meter Chilled Mirror Instruments A precision hygrometer, combining drift free measurement with the flexibility of a remote sensor. Ideal for laboratory and industrial measurements,
More informationPortable Ultrasonic Flow Measuring System prosonic flow 92
Technical Information TI 060D/24/ae Portable Ultrasonic Flow Measuring System prosonic flow 92 Temporary volume flow measurement of liquids with Clamp On sensors Features and benefits Portable transmitter,
More informationZirconia Oxygen Probe
Data Sheet SS/ZFG Issue Zirconia Oxygen Probe ZFG Series Environmental Certification MCERTS SIRA Certificate MC99000 Combustion monitoring control true wet measurement of net excess oxygen in situ measurement
More informationField IT Electro-Magnetic Flowmeters Sensors
Data Sheet Field IT Electro-Magnetic Flowmeters Sensors MagMaster MFE Unrivalled flow performance ±0.2% accuracy. Pulsed DC Technology Incorporates Benefits of AC Systems Operable flow range of 1000:1.
More informationOptions guide. Electromagnetic flowmeters. M9xx
Options guide Electromagnetic flowmeters M9xx Ordering codes Model Description M 910 -V0 0 0 0 DN50 PN16 Example Sensor M Basic Ex Ex certified (remote version only) Transmitter 910E Economic version 910
More informationDL 01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05
DL 0 Battery Powered for Leak Testing Stainless Steel Sensor class 0.05 Nominal pressure from 0 00 mbar up to 0... 00 bar Special characteristics modular sensor concept data logger graphic display stainless
More informationElectro-Magnetic Flowmeters Sensors MagMaster MFE
Data Sheet (US) Electro-Magnetic Flowmeters Sensors MagMaster MFE Unrivalled flow performance ±0.2% accuracy. Pulsed DC Technology Incorporates Benefits of AC Systems Operable flow range of 1000:1. Two-year
More informationSuperstatic 440. Static Heat Meter, Static Cooling Meter. Application
Superstatic 440 Static Heat Meter, Static Cooling Meter Application Design The Superstatic 440 is a static heat or cooling meter according to standard EN1434 class 2 based on the fluid oscillation principle,
More informationUFM 800 W, C and UFM 800 W Hot Tapping. Ultrasonic flowmeters. for water and wastewater
KROHNE 12/2006 7.02343.22.00 MAR UFM 800 W, C and UFM 800 W Hot Tapping Ultrasonic flowmeter for water and wastewater...with weld-in sensors for metal pipelines...with built-on or built-in sensors for
More informationTechnical Datasheet. Multi-channel support RTC with Data Storage RS485 Output Alarming & Protection Onsite Programmable Load Profile Analysis
Preliminary Datasheet Technical Datasheet Compact DC Energy Meter RISH EM DC series is specially designed to measure, display and communicate DC Voltage, Current, Power and Energy to monitor and control
More informationMagnetic-inductive flow meter EPS / UMF2. Technical data sheet
Magnetic-inductive flow meter EPS / UMF2 Technical data sheet high accuracy: 0.3 % of actual maintenance-free no pressure drop numerous lining materials numerous electrode materials low-cost grounding
More informationDifferential Pressure and Flow meters Accessories for the Media Series
Differential Pressure and Flow meters Accessories for the Media Series 7 8 9 10 11 6 12 Media 5 Media 6 Media 05 1 5 2 4 Media 4 3 Selection and application These accessories upgrade the devices of the
More informationflow x3 flow monitoring
flow x3 flow monitoring The FlowX3 System includes a complete range of paddle wheel flow sensors, instruments and sensor installation fittings. Also included are insertion type electromagnetic flow transmitters.
More informationULTRASONIC HEAT METER
MEASURE TODAY. ENSURE TOMORROW. tprime TM Series 280T Applications Residential submetering Commercial buildings District heating / cooling HVAC Green energy management AMR and Billing Features Wear-free.
More informationActuators & Positioners Pneumatic Actuators Series UP1/2/3/4/5/6
Data Sheet Actuators & Positioners Pneumatic Actuators Series UP1/2/3/4/5/6 Wide Range of Torque Ratings - Six actuator sizes available in ratings from 122 to 6372 Newton meters (90 to 4700 foot-pounds)
More informationUnidrive M400 Fast set-up and diagnostics with real-text display, integrated PLC and safety inputs
Unidrive M400 Fast set-up and diagnostics with real-text display, integrated PLC and safety inputs 0.25 kw - 110 kw (0.33 hp - 150 hp) 100 V 200 V 400 V 575 V 690 V Unidrive M400 features Optional AI-485
More informationDM01. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05
Battery Powered Stainless Steel Sensor class 0.05 Nominal pressure from 0 00 mbar up to 0... 00 bar Special characteristics modular sensor concept data logger graphic display stainless steel housing Ø
More informationMEASURE TODAY. ENSURE TOMORROW. SpireMag Series T-MAG Electromagnetic BTU Meter
MEASURE TODAY. ENSURE TOMORROW. SpireMag Series T-MAG Features The T-MAG BTU meter is the latest addition to the SpireMag series for accurate thermal energy measurement. It utilizes a high accuracy electromagnetic
More informationProSeries NEMA 4X SONIC-PRO. Engineering and Technical Data. Transit Time Ultrasonic Flowmeter. Industries, Ltd. s Ultrasonic Flow Meters
ProSeries by Blue-White Industries, Ind. Ltd. Industries, Ltd. s SNIC-PR s SNIC-PR s S4 Transit Time Ultrasonic Flowmeter ½ thru 2 diameter Pipe Sizes Inline spool piece Advanced communications Data logging
More informationDifferential pressure transmitter PASCAL Ci4 Delta P
Differential pressure transmitter PASCAL Ci4 Delta P for diaphragm seal operation, Type series CI4330 Features Application area General process engineering Chemical and petrochemical industry General process
More informationINTELLITROL. scully. Scully s Intellitrol System. Intellitrol is a state of the art microprocessor based system that provides:
INTELLITROL Overfill Prevention Control Unit with Optional Ground Verification and Vehicle Identification Features. Scully s Intellitrol System is the most advanced terminal overfill prevention and ground
More informationOxiperm 164 D for 30 to 2000 g/h
GRUNDFOS alldos product information Oxiperm 164 D for 30 to 2000 g/h Preparation of chlorine dioxide from diluted solutions Measurements Measurements Standard system Front installation system 164-xxxDFI
More informationStandard Features 200-600V, 50/60Hz input power supply Built-in run rated (AC1) By-pass contactor up to 820 A * Rated 450% current Conformal coated circuit board Voltage ramp or current limit start modes
More informationFPD220 meter 2 di Dual-chamber orifice fitting with double isolation
Data sheet DS/FPD220 EN FPD220 meter 2 di Dual-chamber orifice fitting with double isolation Measurement made easy Safety by design Double isolation with visible proofing mechanism meets HSG253 Category
More informationInline Flow meter for compressed air and gases DN15 (1/2 ) - DN80 (3 )
EE771/EE772 Inline Flow meter for compressed air and gases DN15 (1/2 ) - DN80 (3 ) The inline flow meter EE771/EE772, based on the measurement principle of thermal mass flow, is ideally suited for the
More informationOxiperm 164 C for 150 to 2500 g/h
GRUNDFOS alldos product information Oxiperm 164 C for 150 to 2500 g/h Preparation of chlorine dioxide from concentrated solutions Measurements Measurements A G C1 C B M H E F C2 C K L NaClO 2 H O 2 HCl
More informationDMT PERFORMING UNDER PRESSURE DMT. Pressure Scanner Features. Applications. Description 1/7
Features User Accessible Memory for Test Configuration Management ±0.05% FS System Accuracy EU Throughput Rates of 500 Hz Auto-Negotiating 10/100 BaseT Ethernet with TCP & UDP Protocol Pressure Ranges
More informationEM DC Multi-Function DC Energy Meter
Analogue Meters With Moving - Iron Movement EM DC Compact DC Energy Meter Ziegler EM DC series is specially designed to measure, display and communicate DC Voltage, Current, Power and Energy to monitor
More informationOSC is your electric meter expert. When you have questions or need assistance in selecting the proper meter for the job, call us!
Socket Watthour Meters ASK THE EXPERTS OSC is your electric meter expert. When you have questions or need assistance in selecting the proper meter for the job, call us! NEW METERS OSC offers several different
More informationMono Pumps PSS Eco 1-60
Mono Pumps PSS Eco 1-60 Page 1 of 12 Pump Unit Specification G60 Grifter (grinder pump) Specification Specification Topic Manufacturer Model Nominal flow rate Maximum Head capability Flow at Max. Head
More informationABB Instrumentation. 50T Series Transmitters Model 54G/A gauge/absolute pressure transmitter for sanitary use. Specification sheet
Specification sheet 50T Series Transmitters Model 54G/A gauge/absolute pressure transmitter for sanitary use Ranges : - 100 to 4000 kpa - 1 to 40 bar - 14.5 to 600 psi Base accuracy : 0.2%(BFSL) Piezoresistive
More informationPressure transmitter PASCAL CV4
Pressure transmitter PASCAL CV4 with threaded connection, Type series CV4100 Features Application area Pharmaceutical industry Food industry Biotechnology General process technology Compact case of stainless
More informationOxiperm 164 and 166 GRUNDFOS PRODUCT GUIDE. Automated preparation of chlorine dioxide
Being responsible is our foundation Thinking ahead makes it possible Innovation is the essence GRUNDFOS PRODUCT GUIDE Oxiperm 1 and 1 Automated preparation of chlorine dioxide L-OXI-PG-01 1009 009 Grundfos
More informationMarsh McBirney Flo-Dar
Marsh McBirney Flo-Dar Accurate Flow Measurement Flo-Dar TM provides the user with highly accurate flow measurements under a wide range of flows and site conditions. By measuring the velocity of the fluid
More informationSonoMeter 30 Energy Meters
SonoMeter 30 Energy Meters Description The Danfoss SonoMeter 30 is a range of ultrasonic, compact energy meters intended for measuring energy consumption in heating and cooling applications for billing
More informationAccurate measurement of compressed air consumption and detection of leaks. Measuring the individual consumption per customer / cost centre
Inline Flowmeter for compressed air and gases DN15 - DN50 / 16 bar The flow meter of the series, based on the measurement principle of thermal mass flow, is ideally suited for the measurement of flow of
More informationData sheet MULTICAL 6L2. Data loggers Info loggers Data backup in case of power failure MID-2004/22/EC EN 1434
Data sheet MULTICAL 6L2 Data loggers Info loggers Data backup in case of power failure MID-2004/22/EC EN 1434 M15 0200 Contents Calculator functions 3 Cabinet design 7 Approved meter data 8 Electrical
More informationProduct Data Sheet 2012 Rev 5 FLOWMETRIX SA SAFMAG Electromagnetic Flowmeter Doc Date
FLOWMETRIX SA Doc Date 17.07.2012 PERFORMANCE * 0,5% of rate (Standard) * 0,25% of rate (Optional) * 1000 : 1 operable flow range * Excellent repeatability * Optional Bi-directional measurement * Advanced
More informationAlpha EM DC Multi-Function DC Energy Meter. Technical Datasheet. Compact DC Energy Meter
Alpha EM DC Technical Datasheet Compact DC Energy Meter ALPHA EM DC series is specially designed to measure, display and communicate DC Voltage, Current, Power and Energy to monitor and control the target
More informationUTM10 Series Ultrasonic Transit-time Flowmeters
Page 1 of 5 TI-P197-01 MI Issue 1 UTM10 Series Ultrasonic Transit-time Flowmeters Description UTM10 ultrasonic flow and energy meters clamp onto the outside of pipes and do not make contact with the internal
More informationSHARKY 775 COMPACT ENERGY METER ULTRASONIC
APPLICATION The ultrasonic compact energy meter can be used for measuring the energy consumption in heating / cooling application for billing purposes. FEATURES 4 Approval for ultrasonic meter with dynamic
More informationHUMIDITY / TEMPERATURE TRANSMITTER
HUMIDITY / TEMPERATURE TRANSMITTER SEM161, SEM16 CONFIGURATION USING USB PORT POWERED CONFIGURATOR HUMIDITY, TEMPERATURE, DEW POINT MEASUREMENT INTERCHANGEABLE DIGITAL SENSOR HIGH ACCURACY AND STABILITY
More informationmass flowmeter for compressed air
mass flowmeter for compressed air VARIOMASS LC pressure and temperature compensated flowmeter easy and cost effective installation of the senor no pressure loss caused by the sensor no moving parts, i.e.
More informationCooled incubators (ST), laboratory refrigerators
Cooled incubators (), laboratory refrigerators The version has been designed for those customers who look for professional lab equipment at a very competitive price. The cooled incubators () and refrigerators
More informationVortex Plate. Model VP General Specification. Product Features
Vortex Plate Product Features Our Inline meters can measure Steam, Gases or Liquids. Heavy Duty & Maintenance Free Design C&C Machined from one piece of solid stainless steel Absolutely NO o-rings or seals
More information2006/2007 Product Catalog. The World s Leading SOLAR Controllers
2006/2007 Product Catalog The World s Leading SOLAR Controllers OUR COMPANY Morningstar Corporation, founded in 1993, is the world s leading supplier of photovoltaic (PV) controllers. In 2005 we shipped
More informationmass flowmeter for compressed air
mass flowmeter for compressed air VARIOMASS ECO pressure and temperature compensated easy and cost effective installation of the sensor no pressure loss caused by the sensor no moving parts, i.e. maintenance
More informationCombustion Gas Analysis
Data Sheet DS/AZ EN Issue Combustion Gas Analysis Endura AZ Oxygen Monitor Advanced design and precision manufacturing robust, long-life probe for process temperatures up to 8 C (47 F) proven cell design
More informationRefrigerated incubator with Peltier technology
KT series 53 Incubators and cooling incubators Refrigerated incubator with Peltier technology The KT series combines outstanding performance with impressive energy efficiency and environmental friendliness.
More informationEPS / UMF2. Magnetic Inductive Flowmeter for Conductive Liquids
Magnetic Inductive Flowmeter for Conductive Liquids measuring monitoring analyzing EPS / UMF2 High Accuracy: 0.3 % of Actual Flow Maintenance-free No Pressure Drop Wide Variety of Lining and Electrode
More informationIsoil Industria a worldwide supplier of electromagnetic flowmeters Total flow control. Accurate to the drop.
www.isomag.eu Isoil Industria a worldwide supplier of electromagnetic flowmeters Total flow control. Accurate to the drop. 1 THE IDEAL FLOWMETERS FOR ANY APPLICATION from DN03 to DN2400 wide range of process
More informationEAS822 (Contrac) Power Electronic Unit
Contents Data Sheet Rev. A EAS822 (Contrac) Power Electronic Unit For continuous control of Contrac actuators PME120 AN and LME620 AN Microprocessor-controlled power electronic unit with integrated frequency
More informationOven Tracker. Accessories List DATA LOGGER
Oven Tracker Accessories List DATA LOGGER MP0050 MemoryPaq XL2 Data logger Used with Transducer Interface XL2 TI0060/TI0080. Programmable sampling interval (0.5s to 10mins); SmartPaq process pass/fail
More informationTurbidity and Suspended Solids Transmitter
Data Sheet 5.1 We reserve the right to continuously improve our products and make any change in the stated specifications and dimensions without prior notice. DK: NO: SE: NL: USA: AUS: +45 45 56 06 56
More informationDigital Time Switches
Digital Time Switches Precise time programming for Daily/Weekly/Pulse switching 25 ON/OFF programs Weekend Exclusion (FRI SAT or SAT SUN) and Weekly OFF programming LED Indication of Relay status & 12/24
More informationAppendix. Clearance. Skewed profiles. Application Schematics
Appendix Application Schematics The purpose of the application schematics is to show different applications and the best sensor location for a particular application. Clearance Because the sensor will
More informationSonoMeter 30 Energy Meters
SonoMeter 30 Energy Meters Description MID examination certificate no.: LT-1621-MI004-020 The Danfoss SonoMeter 30 is a range of ultrasonic, compact energy meters intended for measuring energy consumption
More informationMODULAR MELT FLOW: The First Step: Melt Flow Index (Weight Method) According to ASTM D 1238, ISO 1133 Method A and other equivalents
MODULAR MELT FLOW: Plug in as you go: if you need more features as your business grows, simply add them on! For instance: digital encoder for Method B, weight lifting device for automation, automatic cutting
More informationModel FVP General Specification. Flanged Vortex Plate. Product Features
Flanged Vortex Plate Product Features Our Inline meters can measure Steam, Gases or Liquids. Measures two times lower than any other Vortex Meter. Heavy Duty & Maintenance Free Design C&C Machined from
More informationCombination ph/redox (ORP) Sensors
Data Sheet Combination ph/redox (ORP) s Series AP00 User-customizable for Insertion, Flow-through, Immersion, Hot-tap Retractor ideal for Original Equipment Manufacturers and general applications Economical
More informationMicro Motion T-Series Straight-Tube Mass Flow and Density Meters. Product Data Sheet PS July 2001
Micro Motion T-Series Straight-Tube Mass Flow and Density Meters Product Data Sheet PS-00371 July 2001 Micro Motion T-Series Straight-Tube Meters Micro Motion is proud to offer you the first single-straight-tube
More informationReadStar & CapStar Range Torque Readouts & Torque Testers. Crane Electronics Inc The force in torque management
ReadStar & CapStar Range Torque Readouts & Torque Testers Crane Electronics Inc The ReadStar range enables the measurement and collection of torque data. The ReadStar range comprises ReadStar II, ReadStar
More informationCombination ph/redox (ORP) Sensors
Data Sheet SS/AP00_ Combination ph/redox (ORP) s AP00 Series User-customizable for Insertion, Flow-through, Immersion and Hot-tap Retractor ideal for OEMs (Original Equipment Manufacturers) and general
More informationPowerCommand 3300 Control Panel. Our Energy Is Working For You.
PowerCommand 3300 Control Panel. Our Energy Is Working For You. PowerCommand Control Panel. The PowerCommand Control Panel (PCC 3300) is a microprocessor-based Drilling Power Module (DPM) monitoring, metering
More informationAquaMaster 3 Electromagnetic flowmeter. The smart solution for potable applications. Introduction
MODBUS Tables Supplement COI/FET2XX/MOD/TBL EN AquaMaster 3 The smart solution for potable applications Introduction AquaMaster 3 TM is a range of high performance electromagnetic flowmeters for the measurement
More informationJUMO MIDAS S05 Pressure transmitter Type
Data Sheet 40.00 Page /8 JUMO MIDAS S05 Pressure transmitter Type 4000 Brief description The JUMO MIDAS S05 pressure transmitter is available with both relative pressure and absolute pressure measurement
More informationLower maintenance costs: with no moving parts, there is nothing on the DFX to wear down. Wide measuring range: 0.15 to 30 FPS (0.05 to 9 MPS).
PRODUCT APPLICATIONS / APPLICATION QUALIFICATION DIMENSIONAL SPECIFICATIONS MECHANICAL DIMENSIONS: INCHES (mm) DOPPLER ULTRASONIC FLOW METER Carbonated liquids Mining slurry Drilling mud Coal-seam water
More informationDSL-240 MkIII Single Pass Dust Monitor Measures mg/m 3 using DDP
Ideal for monitoring dust levels in the exhaust gas of industrial combustion or air filtration processes. Innovative Dynamic Detection Principle (DDP) measurement technique Immune to gradual reductions
More informationEFS EFS 2000 Electric failsafe actuators
EFS 2000 Electric failsafe actuators EFS 2000 Electric failsafe actuators A world of experience Biffi has been a leading manufacturer of valve actuators for more than 50 years. As one of the few manufacturers
More information