SITRANS F M. Flow sensor MAG 1100 F 3/59

Size: px
Start display at page:

Download "SITRANS F M. Flow sensor MAG 1100 F 3/59"

Transcription

1 Overview Integration The complete flowmeter consists of a sensor and an associated transmitter MAG 5000, 6000 and 6000 I. The flexible communication concept USM II simplifies integration and update to a variety of fieldbus systems such as PROFIBUS DP and PA, Modbus RTU/RS 485, HART, FOUNDATION Fieldbus H1, DeviceNet. Pressure/temperature curve; material AISI 16L/ Pressure/temperature curve; material AISI 16L/ bar PN PN 25 PN PN C The electromagnetic sensor MAG 1100 F is designed to meet applications in the food and beverage industry. Benefits sizes: 10 to 100 (/8 to 4 ) AISI 16 stainless steel enclosure : Hygienic connection, A approval and EHEDG certified Sanitary design for CIP / SIP cleaning Conforms to FDA Easy commissioning, the SENSORPROM unit automatically updates settings Hose proof IP67/NEMA 4X enclosure rating Designed that patented in-situ verification can be conducted. Using SENSORPROM fingerprints Application The main applications of the electromagnetic sensors can be found in the following fields: Food industry Beverage industry Pharmaceutical industry Pressure/temperature curve; material AISI 16L/ psi Pressure/temperature curve; material AISI 16L/ PN PN PN PN F For further information on the PED standard and requirements, see page 9/14. Design Unique mechanical design with a wide range of customer specified sanitary connection Compact or remote mounting possible easy "plug & play" field changeable Simple on site upgrade to IP68/NEMA 6P terminal box Ex ATEX 2G D version for hazardous areas (ceramic liner) Mode of operation The flow measuring principle is based on Faraday s law of electromagnetic induction according to which the sensor converts the flow into an electrical voltage proportional to the velocity of the flow. Siemens FI /59

2 Siemens AG 2012 Technical specifications Measuring principle Electromagnetic induction Excitation frequency (¼ 2½ ): (Mains supply: 50 Hz/60 Hz) 12.5 Hz/15 Hz (, 4 ): 6.25 Hz/7.5 Hz Process connection Nominal size (/8" 4") Process connection Hygienic adapters available for: rect welding onto pipe Clamp fitting Threaded fitting Rated operating conditions Ambient conditions Ambient temperature 1) C ( F) Ex sensor C( F) Compact transmitter MAG 5000/6000 2) C( F) Transmitter MAG 6000 I C( F) Compact transmitter C( F) MAG 6000 I Ex de Temperature of medium MAG 1100 F (Ceramic) C ( F) Suitable for steam sterilization C ( F) Suitable for steam steralization at 150 C (02 F) Temperature shock MAG 1100 F Duration 1 min, followed by 10 min rest Operating pressure MAG 1100 F (Ceramic) 10, 15, 25: Max. ΔT 80 C/min (/8, ½, 1 : Max. ΔT 144 F/min) 40, 50, 65: Max. ΔT 70 C/min (1½, 2, 2½ : Max. ΔT 126 F/min) 80, 100: Max. ΔT 60 C/min (, 4 : Max. ΔT 108 F/min) Max. ± 100 C (212 F) momentarily : 40 bar (/8 2½ : 580 psi) 80: 25 bar ( : 6 psi) 100: 25 bar (4 : 6 psi) Vacuum: 1 x 10-6 bar abs (1.5 x 10-5 psi abs ) 20 bar (290 psi) Vacuum: 0.02 bar abs (0. psi abs ) : CO 2 pressure max. 7 bar (101.5 psi) Mechanical load (vibration) Hz random in x, y z, directions for 2 hours according to EN :.17 grms with compact MAG 5000/ 6000 mounted transmitter:.17 gr. with compact MAG 6000 I/MAG 6000 I Ex mounted transmitter: 1.14 grms For compact installation with the MAG 6000 I/MAG 6000 I Ex, transmitter to be supported to avoid tension on sensor part. Enclosure rating IP67 to EN (NEMA 4X), 1mH 2 O for 0 min EMC 2004/108/EC Design Weight See mensional drawings Material Enclosure MAG 1100 F Stainless steel AISI 16L/ Terminal box (remote version only) Standard Fibre glass reinforced polyamide Option Stainless steel AISI 16/1.446 Ex ATEX (remote version only) Stainless steel AISI 16/1.446 Liner MAG 1100 F (Ceramic) Aluminum oxide Al 2 O (ceramics) Reinforced PFA (teflon) (not for Ex) Electrodes MAG 1100 F (Ceramic) Platinum with gold /Titanium brazing alloy (/8"... ½"): Hastelloy C276/ (1"... 4"): Hastelloy C22/ Cable entries Remote installation 2 x M20 or 2x½" NPT Compact installation - MAG 5000/MAG 6000: 4 x M20 or 4 x ½" NPT - MAG 6000 I: 2 x M25 (for supply/output) - MAG 6000 I Ex de: 2 x M25 (for supply/output) Certificates and approvals Calibration Standard Production calibration, Zero-point, 2 x 25 %, 2 x 90 % calibration report shipped with sensor MAG 1100 F (Ceramic) A (sensor with Polyamide terminal box and FKM/FPM or EPDM gaskets), transmitter not part of the approval Ex ATEX approvals for sensor or ATEX 2G D sensor EEx d e ia IIB compact with MAG 6000 I Ex T - T6 with/without FM Class I, v 2 MAG 5000/6000/6000 I A (sensor with Polyamide terminal box with EPDM gasket), transmitter not part of the approval EHEDG certified (use EPDM gasket) ( (1... 4")) FM Class I, v 2 Conforms to PED 97/2/EC ) CRN(PFA) FDA Custody transfer approvals (MAG 5000/6000 CT) Cold water pattern approval PTB (Germany) Hot water pattern approval PTB (Germany) Other media than water pattern approval- OIML R 117 (Ceramic liner)(denmark) 1) Conditions are also dependent on liner characteristics. 2) With compact transmitter MAG 5000 CT/6000 CT C ( F) ) For further information on the PED standard and requirements, see page 9/14. /60 Siemens FI

3 Weld-in adapter for welding onto dairy pipe Tri-Weld, ISO 207, DIN 11850, SMS 008, BS , 15, 25, 40, 50 and 65 PN 40 (600 psi) (/8, ½, 1, 1½, 2 and 2½ ) 80 and 100 (" and 4 ) PN 25 (50 psi) Clamp adapter Tri-Clamp, ISO 2852, DIN 2676, SMS 016, BS , 15, 25, 40 and 50 (/8, ½, PN 16 (200 psi) 1, 1½, and 2 ) 65, 80 and 100 (2½, and 4 ) PN 10 (150 psi) Thread adapter DIN , 15, 25, and 40 (/8, ½, 1, PN 40 (600 psi) and 1½ ) 50, 65, 80 and 100 (2, 2½, PN 25 (50 psi) and 4 ) ISO 285, BS , 15, 25, 40, 50, 65 and 80 PN 16 (200 psi) (/8, ½, 1, 1½, 2, 2½ and ) SMS , 40, 50, 65 and 80 (1, 1½, PN 6 (80 psi) 2, 2½ and ) Design Material Stainless steel AISI 16/1.446 Gasket MAG 1100 F (Ceramic) FKM/FPM with stainless steel insert (AISI 04/1.401) ( C ( F)) EPDM ( C ( F)) EPDM ( C ( F)) NBR ( C ( F)) Note: When combined sensor and adapter, the operating pressure is the lower rated of the pair. Selection and Ordering data MAG 1100 F 7 M E ameter 10 (/8 ) 1 R 15 (½ ) 1 V 25 (1 ) 2 D 40 (1½ ) 2 R 50 (2 ) 2 Y 65 (2½ ) F 80 ( ) M 100 (4 ) T Process connections No adaptors (specials see accessories) A Weld in DIN B ISO 207 (SMS 008) C BS D Tri-Weld E Clamp type DIN 2676 G ISO 2852 (SMS 016) H BS J Tri-Clamp K Threaded type DIN M SMS ) N Liner material PFA (not for Ex) 1 Ceramic 2 Gasket material 1) EPDM flat gasket (FDA, A) 0 FPM/FKM (FDA, A) (only with ceramic liner) 2 EPDM-P gasket (only for PFA) (FDA, EHEDG certified, A) Electrode material Hastelloy C (only with PFA liner) 1 Platinum (only with ceramic liner) 2 Transmitter Standard sensor for remote transmitter (order A transmitter separately), A Ex sensor for remote transmitter (order transmitter B separately) A MAG 6000 I, Alu V DC, V AC C MAG 6000 I, Aluminum V DC, Ex D MAG 6000 I, Aluminum V AC, Ex E MAG 6000, Polyamide, V DC/ V AC H MAG 6000, Polyamide, V AC J MAG 5000, Polyamide, V DC/ K V AC MAG 5000, Polyamide, V AC L Communication No communication, add-on possible A HART B PROFIBUS PA Profile F (only MAG 6000/MAG 6000 I) PROFIBUS DP Profile (not for Ex) G (only MAG 6000/MAG 6000 I) Modbus RTU/RS 485 (not for Ex) E (only MAG 6000/MAG 6000 I) FOUNDATION Fieldbus H1 J (only MAG 6000/MAG 6000 I) 1) SMS 1145 standard is not approved by A Siemens FI /61

4 Siemens AG 2012 Selection and Ordering data MAG 1100 F 7 M E Cable glands/terminal box Metric: Polyamide terminal box or 6000 I compact 1 ½" NPT: Polyamide terminal box or 6000 I compact 2 Metric: SS terminal box (mandatory for Stainless steel MAG 6000 Transmitter) ½" NPT: SS terminal box (mandatory for Stainless 4 steel MAG 6000 Transmitter) Selection and Ordering data Order code Additional information Please add -Z to and specify Order code(s) and plain text. Customer-specific converter setup Y20 Tag name plate, stainless steel fixed with SS wire Y17 (add plain text) Tag name plate, plastic (self adhesive) Y18 Factory certificate according to EN C15 Factory certificate according to EN C14 cables wired (specify cable order no.) Y40 for remote transmitter's junction box potted Y41 with wired cable (specify cable order no.) (not for Ex sensors) Other postproduction requirements (add desired text) Y99 Additional calibrations Matched pair - (Standard production calibration On request 1) where sensor and transmitter is calibrated together) Customer-specified calibration up to 10 points On request 1) Customer-witnessed calibration On request 1) Any of above calibration 1) Ordering "On request" as dedicated information from the customer on the individual sensors is required. Please fill in the calibration form found on and send together with the order. (Size dependent restriction on maximum flow rates may apply Operating instructions for MAG 1100F Description Handbook English A5E This device is shipped with a Quick Start guide and a CD containing further SITRANS F literature. All literature is also available for free at: MAG 5000/6000 transmitters and sensors are packed in separate boxes, the final assembly takes place during installation at the customer's place. MAG 6000 I/MAG 6000 I Ex ATEX 2G D transmitters and sensors are delivered compact mounted from factory. Communication module will be pre-mounted in the transmitter. Please use online Product selector to get latest updates. Product selector link: Description Potting kit for terminal box FDK:085U0220 of flow sensors for IP68/NEMA 6P (not for Ex sensors) /62 Siemens FI Modification 10/2012

5 Weld-in connection fittings for MAG 1100 F with P gaskets for EHEDG Only for sensors with PFA liner. Clamp-type connection fittings for MAG 1100 F with P gaskets for EHEDG Only for sensors with PFA liner. DIN DIN 2676 D 10 2) A5E ) A5E A5E A5E A5E A5E A5E A5E A5E A5E ISO 207 (SMS008) A5E A5E A5E A5E A5E A5E A5E A5E A5E A5E Tri-Weld (BS 485-1) A5E A5E A5E A5E A5E ) A5E A5E ) A5E A5E A5E A5E A5E A5E A5E A5E A5E ISO 2852 (SMS 016, BS 4825-) : outer diameter : inner diameter A5E A5E A5E A5E A5E A5E A5E Tri-Clamp A5E A5E A5E A5E A5E A5E A5E A5E : outer diameter : inner diameter 1) For BS see ISO 207 2) Not EHEDG approved Siemens FI /6

6 Siemens AG 2012 Threaded type connection fittings for MAG 1100 F with P gaskets for EHEDG Only for sensors with PFA liner. DIN Threaded type connection fittings for MAG 1100 F with P gaskets for EHEDG Only for sensors with PFA liner. SMS ) A5E A5E A5E A5E A5E A5E A5E A5E A5E A5E A5E A5E A5E A5E A5E : outer diameter : inner diameter 1) SMS 1145 standard is not approved by A /64 Siemens FI

7 Weld in connection fittings for MAG 1100 F with flat gaskets for A For sensors with ceramic and PFA liner. Clamp-type connection fittings for MAG 1100 F with flat gaskets for A For sensors with ceramic and PFA liner. DIN DIN 2676 D O FDK:08G FDK:08G FDK:08G FDK:08G FDK:08G FDK:08G FDK:08G FDK:08G FDK:08G FDK:08G2125 ISO 207 (SMS008) A5E FDK:08G FDK:08G FDK:08G FDK:08G FDK:08G FDK:08G FDK:08G FDK:08G FDK:08G FDK:08G2105 Tri-Weld (BS ) FDK:08G FDK:08G FDK:08G FDK:08G FDK:08G ) FDK:08G FDK:08G ) FDK:08G FDK:08G FDK:08G FDK:08G FDK:08G FDK:08G FDK:08G2185 ISO 2852 (SMS 016, BS 4825-) : outer diameter : inner diameter FDK:08G FDK:08G FDK:08G FDK:08G FDK:08G FDK:08G FDK:08G2195 Tri-Clamp FDK:08G FDK:08G FDK:08G FDK:08G FDK:08G FDK:08G FDK:08G FDK:08G2295 : outer diameter : inner diameter 1) For BS see ISO 207 Siemens FI /65

8 Siemens AG 2012 Threaded type connection fittings for MAG 1100 F with flat gaskets for A For sensors with ceramic and PFA liner. DIN Threaded type connection fittings for MAG 1100 F with flat gaskets for A For sensors with ceramic and PFA liner. SMS ) FDK:08G FDK:08G FDK:08G FDK:08G FDK:08G FDK:08G FDK:08G FDK:08G FDK:08G FDK:08G2165 ISO FDK:08G FDK:08G FDK:08G FDK:08G FDK:08G2144 : outer diameter : inner diameter 1) SMS 1145 standard is not approved by A FDK:08G FDK:08G FDK:08G FDK:08G FDK:08G2154 BS A5E A5E A5E A5E A5E FDK:08G2145 /66 Siemens FI

9 Spare parts for MAG 1100 F Gaskets (2 pcs., between flow sensor and adapter) - P gaskets Rubber: EPDM (FDA) MAG 1100 F (ceramic) - flat gaskets Rubber: FKM/FPM (FDA) flat gaskets Rubber: EPDM (FDA) Rubber: NBR A5E A5E A5E A5E A5E A5E A5E A5E A5E A5E A5E A5E A5E A5E A5E A5E FDK:08G2206 FDK:08G2207 FDK:08G2209 FDK:08G2211 FDK:08G2212 FDK:08G221 FDK:08G2214 FDK:08G2215 FDK:08G2216 FDK:08G2217 FDK:08G2219 FDK:08G2221 FDK:08G2222 FDK:08G222 FDK:08G2224 FDK:08G2225 Siemens FI /67

10 Siemens AG 2012 mensional drawings MAG 1100 F compact/remote 11 (5.16) 155 (6.10) 218 (8.58) 208 (8.19) 2 x M25 M20 (½"NPT) A1 11 (5.16) A2 B A B1 L D L mensions in mm (inch) Important note: For compact installation with MAG 6000 I/Ex - transmitter to be supported to avoid tension on the sensor part. Size L A ) A 1 B 2) B 1 D Weight 1) (Al 2 O ) PFA [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [kg] Size L A A ) 1 B 2) B 1 D (Al 2 O ) PFA Weight 1) [lb] / ½ ½ ½ ) With transmitter MAG 5000 or MAG 6000 compact, weight is increased by approximately 0.8 kg (1.8 lb) With MAG 6000 I weight is increased with 5.5 kg ( 12.1 lbs) 2) 14.5 mm (0.571 ) shorter when the AISI terminal box is used (always Ex version) ) A 2 is mm (0.12 ) shorter than A 1 /68 Siemens FI

11 MAG 1100 F compact/separate build-in length A L Size A L 1) inch [mm] [mm] 10 / ½ ½ ½ ) The total build-in length L is independent of the adapter type selected. Siemens FI /69

Flow Measurement SITRANS F M

Flow Measurement SITRANS F M Overview The electromagnetic sensor MAG 1100 F is designed to meet applications in the food and beverage industry. Benefits sizes: 10 to 100 (/8 to 4 ) AISI 16 stainless steel enclosure : Hygienic connection,

More information

Flow Measurement SITRANS F M. Flow sensor MAG 1100 F 4/57

Flow Measurement SITRANS F M. Flow sensor MAG 1100 F 4/57 Overview Integration The complete flowmeter consists of a sensor and an associated transmitter MAG 5000, 6000 and 6000 I. The flexible communication concept USM II simplifies integration and update to

More information

Flow Measurement SITRANS F M

Flow Measurement SITRANS F M Overview The electromagnetic sensor MAG 1100 F is designed to meet applications in the food and beverage industry. Benefits sizes: 10 to 100 (/8 to 4 ) AISI 16 stainless steel enclosure : Hygienic connection,

More information

Flow Measurement SITRANS F M. Flow sensor MAG /85. Overview

Flow Measurement SITRANS F M. Flow sensor MAG /85. Overview Siemens AG 2010 low Measurement Overview Design Compact or remote mounting possible Easy plug & play field changeability of transmitter Ex ATEX and M/CSA versions High temperature sensor for applications

More information

Flow Measurement SITRANS F M. Flow sensor MAG 5100 W. 4/68 Siemens FI Overview

Flow Measurement SITRANS F M. Flow sensor MAG 5100 W. 4/68 Siemens FI Overview Flow Measurement Siemens G 2010 Overview pplication The main applications of the electromagnetic flow sensors can be found in the following fields: Water abstraction Water treatment Water distribution

More information

Flow Measurement SITRANS F C. Flow sensor MASS 2100 DI 3 to DI 40. 4/180 Siemens FI

Flow Measurement SITRANS F C. Flow sensor MASS 2100 DI 3 to DI 40. 4/180 Siemens FI Siemens AG Flow sensor MASS DI 3 to DI 0 Overview MASS DI 3 to DI 0 is suitable for accurate mass flow measurement of a variety of liquids and gases. The sensor offers superior performance in terms of

More information

OPTIFLUX 6000 Technical Datasheet

OPTIFLUX 6000 Technical Datasheet OPTIFLUX 6000 Technical Datasheet Electromagnetic flow sensor for hygienic and sanitary applications Robust stainless steel housing for hygienic and aseptic operation Fully suitable for CIP and SIP Typical

More information

SITRANS F C MASSFLO Practical examples of ordering. MASS2100 & MASS6000 IP67 Compact mounted

SITRANS F C MASSFLO Practical examples of ordering. MASS2100 & MASS6000 IP67 Compact mounted SITRNS F C MSSFLO MSS2100 & MSS6000 IP67 Compact mounted Mass 2100 sensor DI 3 - DI 40 MSS 6000 IP67 transmitter. Use ordering code FI 01 Catalogue p. 4/140 MSS system: 7ME4100-2EC21-2D1 FI 01 catalogue

More information

SITRANS F flowmeters SITRANS F C

SITRANS F flowmeters SITRANS F C SITRNS F flowmeters Siemens G 2008 Overview is available as a standard version (DN 50 to DN 150 (2 to 6 )) and a hygienic, EHEDG certified version (DN 20 to DN 80 (¾ to 3 )). MC2 and MC2 hygienic are suitable

More information

Flow Measurement SITRANS F C

Flow Measurement SITRANS F C Overview Benefits It is compact and light, fitting neatly into dense piping arrangements Effective separation of measurement from plant vibration Reliable measurements due to high signal to noise ratio

More information

SITRANS F C. Flow sensor MC2 4/193. Overview

SITRANS F C. Flow sensor MC2 4/193. Overview Siemens G 2011 low Measurement SITNS C Overview The main applications of the Coriolis flowmeter can be found in all industries, such as: Chemical and pharma Detergents, bulk chemicals, pharmaceuticals,

More information

SITRANS F flowmeters SITRANS F C SITRANS F C MC2 4/169. Overview

SITRANS F flowmeters SITRANS F C SITRANS F C MC2 4/169. Overview Siemens G 2009 SITRNS flowmeters SITRNS C SITRNS C MC2 Overview SITRNS C MC2 is available as a standard version (DN 50 to DN 150 (2 to 6 )) and a hygienic, EHEDG-certified version (DN 20 to DN (¾ to 3

More information

Level Measurement Point level measurement - RF Capacitance switches

Level Measurement Point level measurement - RF Capacitance switches Pointek CLS200 - Standard Overview Configuration Installation Pointek CLS200 (standard version) is a versatile inverse frequency shift capacitance level and material detection switch with optional rod/cable

More information

Electromagnetic Flowmeters SITRANS F M MAG 1100 sensor

Electromagnetic Flowmeters SITRANS F M MAG 1100 sensor Introduction 1 Safety notes 2 Description 3 Electromagnetic Flowmeters Operating Instructions Installing/Mounting 4 Connecting 5 Service and maintenance 6 Troubleshooting 7 Technical data 8 Appendix A

More information

Flow Measurement SITRANS F C

Flow Measurement SITRANS F C Overview The complete flowmeter system SITRANS FC40 can be ordered for standard, hygienic or NAMUR service. All versions can be ordered for CT service, according to OIML R 117 (Liquids other than water)

More information

Level instruments. Continuous level measurement - Capacitance transmitters SITRANS LC300. 5/262 Siemens FI Overview.

Level instruments. Continuous level measurement - Capacitance transmitters SITRANS LC300. 5/262 Siemens FI Overview. Overview Configuration is an inverse frequency shift capacitance continuous It is ideal for standard industrial applications in chemical, hydrocarbon processing, food and beverage and mining, aggregate

More information

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. 4/18 Siemens FI Overview.

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. 4/18 Siemens FI Overview. Pointek CLS200 Standard Overview Configuration Installation Pointek CLS200 (standard version) is a versatile inverse frequency shift capacitance level switch with optional rod/cable choices liquids, solids,

More information

VersaFlow Mag 3000 Electromagnetic Flow Sensor Technical Datasheet. Specification

VersaFlow Mag 3000 Electromagnetic Flow Sensor Technical Datasheet. Specification VersaFlow Mag 3000 Electromagnetic Flow Sensor Technical Datasheet 34-VF-03-23 August 27th, 2008 Specification Sanitary and hygienic solution The VersaFlow Mag 3000 is the electromagnetic flow sensor for

More information

SITRANS F M flow sensors 711/A and 711/911E

SITRANS F M flow sensors 711/A and 711/911E s flow sensors 711/A and 711/911E flow sensors 711/A and 711/911E Introduction Application Mode of operation, operation Mode of operation All electromagnetic flow measurements are based on Faraday s Law

More information

SITRANS P measuring instruments for pressure

SITRANS P measuring instruments for pressure Overview Application The pressure transmitter is designed for the special requirements of the food, pharmaceutical and biotechnology industries. The use of high-grade materials guarantees compliance with

More information

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. icenta Controls Ltd

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. icenta Controls Ltd Pointek CLS200 Standard Overview Configuration Installation Pointek CLS200 (standard version) is a versatile inverse frequency shift capacitance level switch with optional rod/cable choices liquids, solids,

More information

Flow Measurement SITRANS F C

Flow Measurement SITRANS F C Siemens G 2014 SITRNS C Overview The main applications of the Coriolis flowmeter can be found in all industries, such as: Chemical and pharma Detergents, bulk chemicals, pharmaceuticals, acids, alkalis

More information

Magnetic-inductive flow meter EPS / UMF2. Technical data sheet

Magnetic-inductive flow meter EPS / UMF2. Technical data sheet Magnetic-inductive flow meter EPS / UMF2 Technical data sheet high accuracy: 0.3 % of actual maintenance-free no pressure drop numerous lining materials numerous electrode materials low-cost grounding

More information

VersaFlow Mag 3000 Electromagnetic Flow Sensor Technical Datasheet. Specification

VersaFlow Mag 3000 Electromagnetic Flow Sensor Technical Datasheet. Specification VersaFlow Mag 3000 Electromagnetic Flow Sensor Technical Datasheet Sanitary and hygienic solution The VersaFlow Mag 3000 is the electromagnetic flow sensor for the food and beverage industry. The 3000

More information

SITRANS FC. Flowmeter SITRANS FC410

SITRANS FC. Flowmeter SITRANS FC410 Siemens AG 2013 Flow Measurement Overview The Coriolis flowmeter 410 consists of a SITRANS FCS400 sensor and a T010 transmitter, always compact mounted. It is based on the latest developments within digital

More information

SITRANS F flowmeters SITRANS F C MASSFLO MASS MC1. 4/146 Siemens FI Overview

SITRANS F flowmeters SITRANS F C MASSFLO MASS MC1. 4/146 Siemens FI Overview Overview MSS 2100 MC1 DN 50 to DN 150 (2 to 6 ) is suitable for accurate mass flow measurement for all kind of liquids and gases. The sensor offers superior performance in terms of flow accuracy, turn-down

More information

Level Measurement. Continuous level measurement - Capacitance transmitters SITRANS LC500. 5/282 Siemens FI Overview.

Level Measurement. Continuous level measurement - Capacitance transmitters SITRANS LC500. 5/282 Siemens FI Overview. SITRANS LC00 Overview Configuration Installation Build up of material or condensation in active shield area does not affect switch operation. SITRANS LC00 is an inverse frequency shift capacitance level

More information

Metal tube variable area flowmeter for gases, liquids and steam

Metal tube variable area flowmeter for gases, liquids and steam Metal tube variable area flowmeter for gases, liquids and steam Metallic or plastic tube with a robust construction Indication by means of magnetic coupling Scales calibrated in l/h, m 3 /h, kg/h, t/h,

More information

SITRANS T measuring instruments for temperature

SITRANS T measuring instruments for temperature for installation in pipelines and tanks Overview The resistance thermometer is designed for installation in tanks and pipelines as well as for the measurement of temperature with hygiene requirements.

More information

INSTRUCTIONS SITRANS F M MAGFLO Electromagnetic flowmeter type MAG 1100 FOOD, DN 10 - DN 100

INSTRUCTIONS SITRANS F M MAGFLO Electromagnetic flowmeter type MAG 1100 FOOD, DN 10 - DN 100 s INSTRUCTIONS SITRANS F M MAGFLO Electromagnetic flowmeter type MAG 1100 FOOD, DN 10 - DN 100 ENGLISH 083R9057 Introduction Siemens Flow Instruments SITRANS F M MAGFLO electromagnetic flowmeters consist

More information

Electromagnetic flowmeters Series FLOMAT Insertion electromagnetic flowmeter for conductive liquids

Electromagnetic flowmeters Series FLOMAT Insertion electromagnetic flowmeter for conductive liquids Electromagnetic flowmeters Series FLOMAT Insertion electromagnetic flowmeter for conductive liquids For use in large diameter pipes as an economical solution for flow measurement Flow rate measurement

More information

Smart Electromagnetic Flowmeter Detector for Sanitary use

Smart Electromagnetic Flowmeter Detector for Sanitary use MagneW3000 PLUS Smart Electromagnetic Flowmeter Detector for Sanitary use Model MGS28U OVERVIEW The MagneW3000 PLUS Smart Electromagnetic Flowmeter for Sanitary use is a high-performance and highly-reliable

More information

Diaphragm seal with sterile connection With clamp connection (Tri-clamp) Models , and

Diaphragm seal with sterile connection With clamp connection (Tri-clamp) Models , and Pressure Diaphragm seal with sterile connection With clamp connection (Tri-clamp) Models 990.22, 990.52 and 990.53 WIKA data sheet DS 99.41 for further approvals see page 7 Applications Sanitary applications

More information

Metal tube flowmeters. Series SC250. Metal Tube Flow Meters. Series SC250. Variable area flowmeter for liquids, gases and steam

Metal tube flowmeters. Series SC250. Metal Tube Flow Meters. Series SC250. Variable area flowmeter for liquids, gases and steam Metal tube flowmeters Variable area flowmeter for liquids, gases and steam Metallic or plastic tube with a robust construction Indication by means of magnetic coupling Scales calibrated in l/h, m 3 /h,

More information

Electromagnetic flowmeters Series FLOMID Electromagnetic flowmeter for conductive liquids

Electromagnetic flowmeters Series FLOMID Electromagnetic flowmeter for conductive liquids Electromagnetic flowmeters Series FLOMID Electromagnetic flowmeter for conductive liquids Flow rate measurement is independent of density, temperature, viscosity and pressure Pulsed coil excitation to

More information

Continuous level measurement Capacitance transmitters

Continuous level measurement Capacitance transmitters Siemens AG 2011 Level Measurement SITRANS LC00 Overview Configuration Installation Build up of material or condensation in active shield area does not affect switch operation. SITRANS LC00 is an inverse

More information

SENSOR MUT2400EL. Electromagnetic flowmeter. The electromagnetic flowmeter designed for food industry DS200-1-ENG

SENSOR MUT2400EL. Electromagnetic flowmeter. The electromagnetic flowmeter designed for food industry DS200-1-ENG The electromagnetic designed for food industry DS200-1-ENG The is specifically designed for use in the food processing industry. It is made of materials approved by international regulations, compatible

More information

DMP 331P. Industrial Pressure Transmitter. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

DMP 331P. Industrial Pressure Transmitter. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm DMP P Industrial Pressure Transmitter Pressure Ports And Process Connections With Flush Welded Stainless Steel accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 % FSO from 0... 00 mbar up

More information

Level Measurement Point level measurement - RF Capacitance switches

Level Measurement Point level measurement - RF Capacitance switches Overview Configuration Installation is an inverse frequency shift capacitance level and material detection switch ideal for detecting interfaces, solids, liquids, toxic, and aggressive chemicals in critical

More information

DMP 331P DMP 331P. Industrial Pressure Transmitter. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

DMP 331P DMP 331P. Industrial Pressure Transmitter. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm DMP P Industrial Pressure Transmitter Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 % FSO Industrial

More information

Food & beverage. Oil & gas. Water & waste water

Food & beverage. Oil & gas. Water & waste water Overview MSS 2100 MC1 DN 50 to DN 150 (2 to 6 ) are suitable for accurate mass flow measurement for all kind of liquids and gases. The sensor offers superior performance in terms of flow accuracy, turn-down

More information

KROHNE 10/ Optimass 70 & 71 Single Tube Coriolis Mass Flowmeters for Food & Beverage Processing

KROHNE 10/ Optimass 70 & 71 Single Tube Coriolis Mass Flowmeters for Food & Beverage Processing KROHNE 10/02 7.02442.21.00 GR Optimass 70 & 71 Single Tube Coriolis Mass Flowmeters for Food & Beverage Processing Optimass One Tube... Optimass is a brand new family of Coriolis mass flowmeters from KROHNE.

More information

JUMO flowtrans MAG Series. Electromagnetic flowmeters for the process industry and for hygienic applications

JUMO flowtrans MAG Series. Electromagnetic flowmeters for the process industry and for hygienic applications JUMO flowtrans MAG Series Electromagnetic flowmeters for the process industry and for hygienic applications Contact Phone: +49 661 6003-715 Email: sensors@jumo.net Dear Reader, Until now, JUMO has relied

More information

Diaphragm seal with sterile connection For sanitary applications Models , , and , threaded connection

Diaphragm seal with sterile connection For sanitary applications Models , , and , threaded connection Diaphragm seals Diaphragm seal with sterile connection For sanitary applications Models 990.18, 990.19, 990.20 and 990.21, threaded connection WIKA data sheet DS 99.40 for further approvals see page 3

More information

KROHNE 10/ Optimass 70 & 71 Single Tube Coriolis Mass Flowmeters for the Pharmaceutical Industry

KROHNE 10/ Optimass 70 & 71 Single Tube Coriolis Mass Flowmeters for the Pharmaceutical Industry KROHNE 10/02 7.02444.21.00 GR Optimass 70 & 71 Single Tube Coriolis Mass Flowmeters for the Pharmaceutical Industry Optimass One Tube... Optimass is a brand new family of Coriolis mass flowmeters from

More information

7000 Series OPTIMASS Mass Flowmeters. Titanium Hastelloy Stainless Steel

7000 Series OPTIMASS Mass Flowmeters. Titanium Hastelloy Stainless Steel KROHNE 04/2004 7.02445.24.00 GR 7000 Series OPTIMASS Mass Flowmeters with single straight measuring tube Titanium Hastelloy Stainless Steel Status: 10/99 Status: 10/99 One tube no limits No limits with

More information

STEEMCO-MAS Flowmeter for Steam

STEEMCO-MAS Flowmeter for Steam STEEMCO-MAS Flowmeter for Steam Typical Applications The STEEMCO-MAS flow meters measure the mass flow of superheated steam within the process industries, including chemical, petro-chemical, pharmaceutical

More information

Point level measurement Capacitance switches

Point level measurement Capacitance switches Pointek CLS300 Standard Overview Configuration Installation Pointek CLS300 (standard version) is an inverse frequency shift capacitance level switch with optional rod/cable choices and configurable output.

More information

OPTIMASS 3000 Technical Datasheet

OPTIMASS 3000 Technical Datasheet OPTIMASS 3000 Technical Datasheet Sensor for mass flow First choice for low flow applications Certified secondary pressure containment A common footprint for all three sizes, in Hastelloy or Stainless

More information

Ultimate Low Flow Coriolis Mass Flowmeter

Ultimate Low Flow Coriolis Mass Flowmeter RHM 015 - Ultimate Low Flow Coriolis Mass Flowmeter The RHM 015 can reliably measure flow rates as low as 1 g/min (0.002 lb/min). With its extremely wide turn-down ratio of 300 to 1, this model is perfect

More information

Magnetic-Inductive Flow Meter FMI

Magnetic-Inductive Flow Meter FMI SENSORS FOR FOOD AND BIO. Product information FMI-C, FMI-R FOOD Magnetic-Inductive Flow Meter FMI Application/Specified usage Magnetic-inductive flowmeter for the measurement of flow rate and volume in

More information

JUMO dtrans p20. Process pressure transmitter. Type Brief description. Key features. Block diagram

JUMO dtrans p20. Process pressure transmitter. Type Brief description. Key features. Block diagram Data Sheet 403025 Page 1/10 JUMO dtrans p20 Process pressure transmitter Brief description The JUMO dtrans p20 pressure transmitter with HART interface combines maximum precision with easy operation. It

More information

Diaphragm seal with sterile connection With union nut (milk thread fitting) Models , , and

Diaphragm seal with sterile connection With union nut (milk thread fitting) Models , , and Pressure Diaphragm seal with sterile connection With union nut (milk thread fitting) Models 990.18, 990.19, 990.20 and 990.21 WIKA data sheet DS 99.40 for further approvals see page 7 Applications Food

More information

Pressure measurement PP20H Fully welded hygienic pressure sensor with flush membrane

Pressure measurement PP20H Fully welded hygienic pressure sensor with flush membrane Product highlights All market typical hygienic connections available EHEDG & 3-A certified versions available Condensate-proof measuring cell IO-Link available Space-saving installations from DN 25 on

More information

Level Measurement Continuous level measurement - Capacitance transmitters

Level Measurement Continuous level measurement - Capacitance transmitters Overview Probe Applications Rod version Rod version with stilling well Cable version PFA coated cable version Extended cable with rod version Conductive liquids, slurries or solids Conductive liquids or

More information

Magnetic Inductive Flow

Magnetic Inductive Flow GHM Messtechnik GmbH Hans-Sachs-Str. 26 93128 Regenstauf Germany Fon +49 (0) 9402-9383 - 0 Fax +49 (0) 9402-9383 - 33 www.ghm-messtechnik.de info@ghm-messtechnik.de Magnetic Inductive Flow Characteristics

More information

Flow Measurement SITRANS F C

Flow Measurement SITRANS F C Flow sensor SITRNS FCS200 Overview Function The flow measuring principle is based on the Coriolis effect. See "System information ". Integration The complete flowmeter consists of the sensor (SITRNS FCS200)

More information

ORIMAS Mass Flowmeter

ORIMAS Mass Flowmeter Typical Applications ORIMAS Mass Flowmeter The ORIMAS mass flow meters measure the mass flow of most liquids and gases within the process industries, including chemical, petro-chemical, pharmaceutical

More information

Pressure Measurement

Pressure Measurement Siemens AG 202 /2 Product overview Transmitters for basic requirements /5 SITRANS P200 for gauge and absolute pressure / SITRANS P20 for gauge pressure /6 SITRANS P220 for gauge pressure /22 SITRANS P250

More information

Vortex Flowmeters VFM 3100 F-T VFM 3100 W-T

Vortex Flowmeters VFM 3100 F-T VFM 3100 W-T KROHNE 10/2001 7.02313.23.00 GR/OP Vortex Flowmeters F-T W-T Variable area flowmeters Vortex flowmeters Flow controllers Electromagnetic flowmeters Ultrasonic flowmeters Mass flowmeters Level measuring

More information

VersaFlow Coriolis 100 Mass Flow Sensor Specifications

VersaFlow Coriolis 100 Mass Flow Sensor Specifications VersaFlow Coriolis 100 Mass Flow Sensor Specifications 34-VF-03-09 May 2011 The Universal Solution for the Process Industry VERSAFLOW is the only sensor for mass flow in its class with secondary pressure

More information

Level Measurement. Point level measurement Capacitance switches. Pointek CLS300 Standard. 5/42 Siemens FI Overview.

Level Measurement. Point level measurement Capacitance switches. Pointek CLS300 Standard. 5/42 Siemens FI Overview. Level Measurement Pointek CLS300 Standard Siemens AG 20 Overview Configuration Installation Pointek CLS300 (standard version) is an inverse frequency shift capacitance level switch with optional rod/cable

More information

Coriolis Mass Flowmeter for low flow measurements

Coriolis Mass Flowmeter for low flow measurements RHM 03 - Flexible Coriolis Mass Flowmeter for low flow measurements The RHM 03 can measure flow rates up to 5 kg/min (11 lb/min) with temperatures in excess of 400 C and pressures to 868 bar. This model

More information

Temperature Measurement Resistance thermometers

Temperature Measurement Resistance thermometers Temperature transmitters for mounting in the connection head The following temperature transmitters are available for mounting in the connection head: SITRANS TH100 Programmable two-wire temperature transmitter

More information

Magnetic-Inductive flow Meter fmi

Magnetic-Inductive flow Meter fmi 1 Product information fmi-c, fmi-r f o o d P H A R M A Magnetic-Inductive flow Meter fmi Application / Specified Usage Certification Magnetic-inductive flowmeter for the measurement of flow rate and volume

More information

The EPSILON is based on the principle of measuring velocity in the pipe line, therefore the flow measurement is volumetric.

The EPSILON is based on the principle of measuring velocity in the pipe line, therefore the flow measurement is volumetric. Typical Applications EPSILON Flowmeter The EPSILON flow meters measure the flow of most liquids and gases within the process industries, including chemical, petro-chemical, pharmaceutical and the power

More information

Level Probes multicap T DC 12 TE multicap T DC 11/16/21/26 TEN/TES

Level Probes multicap T DC 12 TE multicap T DC 11/16/21/26 TEN/TES Technical Information TI 240F/00/en Level Probes multicap T DC 12 TE multicap T DC 11/16/21/26 TEN/TES Compact capacitive level probes (with European certificates). Fully and partially insulated rod and

More information

Glass tube flowmeters Series 6000 Variable area flowmeter for liquids and gases

Glass tube flowmeters Series 6000 Variable area flowmeter for liquids and gases Glass tube flowmeters Series 6000 Variable area flowmeter for liquids and gases Easy installation Local indication by means of direct reading Low pressure drop Scales directly in l/h, m 3 /h, kg/h, l/min,

More information

Electromagnetic Flow Meter Owner s Manual HARDWARE

Electromagnetic Flow Meter Owner s Manual HARDWARE Electromagnetic Flow Meter Owner s Manual HARDWARE Compact Magnetic Flowmeter (Flange Connection) Sanitary Magnetic Flowmeter (Tri clamp Connection) Part No. 910000 Rev.C Content 1. GENERAL INFORMATION...2

More information

STEEMCO Flowmeter for Steam

STEEMCO Flowmeter for Steam STEEMCO Flowmeter for Steam Typical Applications The STEEMCO flow meters measure the flow of saturated and superheated steam within the process industries, including chemical, petro-chemical, pharmaceutical

More information

Proline Promag 10H, 50H, 53H, 55H

Proline Promag 10H, 50H, 53H, 55H Supplementary documentation for the Operating Instructions Supplementary information to following modifications: - New nominal diameters DN 125 to 150 (5 to 6") - New process connections for nominal diameters

More information

SITRANS F X SITRANS FX300 3/355

SITRANS F X SITRANS FX300 3/355 Siemens AG 204 Flow Measurement Overview vortex flowmeters provide accurate volumetric and mass flow measurement of steam, gases and liquids as an all-in-one solution with integrated temperature and pressure

More information

RHM 04 - Universal Coriolis Mass Flowmeter with particular Fast Response

RHM 04 - Universal Coriolis Mass Flowmeter with particular Fast Response RHM 04 - Universal Coriolis Mass Flowmeter with particular Fast Response The RHM 04 can measure flow rates up to 10 kg/min (21 lb/min) with extremely fast response times and excellent repeatability. A

More information

Description Version Enclosure Supply Order No. Symbol SONO 3000 transmitter for compact and wall mounting IP67 (NEMA 4X/6)

Description Version Enclosure Supply Order No. Symbol SONO 3000 transmitter for compact and wall mounting IP67 (NEMA 4X/6) Spare part SONO 3000 transmitter, available standard versions Description Version Enclosure Supply SONO 3000 transmitter for compact and wall mounting IP67 (NEMA 4X/6) Fibre glass reinforced polyamid 115

More information

OPTIFLUX Electromagnetic Flow Sensor

OPTIFLUX Electromagnetic Flow Sensor OPTIFLUX 2000 Technical Datasheet Electromagnetic Flow Sensor Engineered and manufactured for the water and wastewater industry All relevant approvals for potable water Long-term reliability and durability

More information

Metal tube flowmeters Series M21 Variable area flowmeter for low flows of liquids, gases and steam

Metal tube flowmeters Series M21 Variable area flowmeter for low flows of liquids, gases and steam Metal tube flowmeters Series M21 Variable area flowmeter for low flows of liquids, gases and steam Metallic tube with a robust construction Indication by means of magnetic coupling Scales calibrated in

More information

Cleanfit H CPA475. Technical Information. Retractable assembly for ph, ORP measurement under sterile conditions

Cleanfit H CPA475. Technical Information. Retractable assembly for ph, ORP measurement under sterile conditions Technical Information Cleanfit H CPA475 Retractable assembly for ph, ORP measurement under sterile conditions Application Food industry Beverage industry Pharmaceutical industry Drinking water The retractable

More information

SATRON VT Pressure Transmitter

SATRON VT Pressure Transmitter SATRON VT pressure transmitter belongs to the series V-transmitters. SATRON VT is used for 0-1.4 kpa...0-100 MPa ranges. It is a 2-wire transmitter with HART standard communication. In pressure measuring

More information

RHM 12 - Standard 1 inch Coriolis Mass Flowmeter

RHM 12 - Standard 1 inch Coriolis Mass Flowmeter RHM 12 - Standard 1 inch Coriolis Mass Flowmeter The RHM 12 can measure flow rates up to 100 kg/min with temperatures in excess of 400 C and pressures up to 290 bar. This model is truly a versatile solution,

More information

Diaphragm pressure gauge, flush For sanitary applications Model PG43SA-S, NS 100

Diaphragm pressure gauge, flush For sanitary applications Model PG43SA-S, NS 100 Pressure Diaphragm pressure gauge, flush For sanitary applications Model PG43SA-S, NS 100 WIKA data sheet PM 04.16 Applications for further approvals see page 10 Hygienic pressure measurement in sanitary

More information

OPTIMASS 2000 Technical Datasheet

OPTIMASS 2000 Technical Datasheet OPTIMASS 2000 Technical Datasheet Sensor for bulk mass flow Large diameter for bulk measurement and custody transfer of liquids and gases Stainless Steel measuring tubes (NACE Compliant) Modular electronics

More information

Isoil Industria a worldwide supplier of electromagnetic flowmeters Total flow control. Accurate to the drop.

Isoil Industria a worldwide supplier of electromagnetic flowmeters Total flow control. Accurate to the drop. www.isomag.eu Isoil Industria a worldwide supplier of electromagnetic flowmeters Total flow control. Accurate to the drop. 1 THE IDEAL FLOWMETERS FOR ANY APPLICATION from DN03 to DN2400 wide range of process

More information

Level limit switch Series RF 3000 Selection list

Level limit switch Series RF 3000 Selection list Table of content Page Overview P2 Applications P4 ------------------------------------------------------------------------------------------------------------- RF 3100 Standard version P6 -------------------------------------------------------------------------------------------------------------

More information

Resistance thermometer For sanitary applications Model TR22-A, exchangeable sensor

Resistance thermometer For sanitary applications Model TR22-A, exchangeable sensor Electrical temperature measurement Resistance thermometer For sanitary applications Model TR22-A, exchangeable sensor WIKA data sheet TE 60.22 for further approvals see page 14 Applications Sanitary applications

More information

Plastic tube variable area flowmeter for liquids and gases

Plastic tube variable area flowmeter for liquids and gases Plastic tube variable area flowmeter for liquids and gases Low cost, excellent readability and light weight Simple installation (flanged, threaded or socket ends for solvent or fusion welding connections)

More information

JUMO DELOS SI. Precision pressure transmitter with switching contacts and display. Application. Brief description. Key features.

JUMO DELOS SI. Precision pressure transmitter with switching contacts and display. Application. Brief description. Key features. Data sheet 405052 Page 1/10 JUMO DELOS SI Precision pressure transmitter with switching contacts and display Application Food & pharma CIP/SIP systems Machine and system construction Air conditioning and

More information

Resistance thermometer For sanitary applications Model TR22-B, for orbital welding

Resistance thermometer For sanitary applications Model TR22-B, for orbital welding Electrical temperature measurement Resistance thermometer For sanitary applications Model TR22-B, for orbital welding WIKA data sheet TE 60.23 for further approvals see page 11 Applications Sanitary applications

More information

p Additional dimensions see section dimensions.

p Additional dimensions see section dimensions. Hydrostatic pressure sensor Dimensions LHC-M20 with process connection G51 74 LHC-M40 with process connection F76 74 232.5 60 261 G1½ 28 20 Ø22 p Additional dimensions see section dimensions. Function

More information

EPS / UMF2. Magnetic Inductive Flowmeter for Conductive Liquids

EPS / UMF2. Magnetic Inductive Flowmeter for Conductive Liquids Magnetic Inductive Flowmeter for Conductive Liquids measuring monitoring analyzing EPS / UMF2 High Accuracy: 0.3 % of Actual Flow Maintenance-free No Pressure Drop Wide Variety of Lining and Electrode

More information

Magnetic-inductive flow meter for hazardous areas

Magnetic-inductive flow meter for hazardous areas Magnetic-inductive flow meter for hazardous areas Technical Datasheet EPX / UMF3 high accuracy: 0.3 % of actual maintenance-free no pressure drop numerous lining materials numerous electrode materials

More information

RHM 03 a1 - (low stress in welds and increased wall thickness against abrasion) RHM bar APPLICATIONS. Batching Dosing. Injections Filling

RHM 03 a1 - (low stress in welds and increased wall thickness against abrasion) RHM bar APPLICATIONS. Batching Dosing. Injections Filling RHM 03 a1 - RHM 03 0.05 ~ 5 kg/min (11 lb/min), -200 ~ 400 C, APPLICATIONS Batching Dosing Injections Filling FEATURES 868 bar 0.005 kg/min ~ 5 kg/min (11 lb/min) 0.1% 0.05% process connection. ADVANTAGES

More information

SITRANS P measuring instruments for pressure

SITRANS P measuring instruments for pressure Overview Siemens AG 009 Supplementary electronics for 4-wire connection Design Dimensions (W x H x D) in mm (inch) Electrical connection 80 x 10 x 60 (3.15 x 4.7 x.36) Screw terminals (Pg 13.5 cable inlet)

More information

Cleanfit CPA471. Technical Information. Compact retractable assembly for installation of ph, ORP electrodes in tanks or pipelines

Cleanfit CPA471. Technical Information. Compact retractable assembly for installation of ph, ORP electrodes in tanks or pipelines Technical Information Cleanfit CPA471 Compact retractable assembly for installation of ph, ORP electrodes in tanks or pipelines Application Chemical industry Wastewater treatment Plant design Tanks and

More information

VersaFlow Vortex 100 Vortex Flow Meter Specifications

VersaFlow Vortex 100 Vortex Flow Meter Specifications VersaFlow Vortex 100 Vortex Flow Meter Specifications 34-VF-03-05 May 2011 The All-In-One Solution The VERSAFLOW is the only vortex flowmeter with integrated and temperature compensation in 2- wire technology.

More information

RHM 03. Flexible Coriolis Mass Flowmeter for low flow measurements. Applications. Features. Advantages

RHM 03. Flexible Coriolis Mass Flowmeter for low flow measurements. Applications. Features. Advantages RHM 03 Flexible Coriolis Mass Flowmeter for low flow measurements The RHM 03 can measure flow rates up to 5 kg/min (11 lb/min) with temperatures in excess of 400 C and pressures to 868 bar. This model

More information

Resistance Temperature Sensors for Hygienic and Sanitary Applications

Resistance Temperature Sensors for Hygienic and Sanitary Applications Product Data Sheet Resistance temperature sensors for applications in the food and beverage, pharmaceutical and life-science industries Aseptic process connections suitable for CIP and SIP dead-pocked

More information

RHM 80 - Coriolis Mass Flowmeter for large flow applications optional heavy duty version

RHM 80 - Coriolis Mass Flowmeter for large flow applications optional heavy duty version RHM 80 - Coriolis Mass Flowmeter for large flow applications optional heavy duty version The RHM 80 can measure flow rates up to 480 t/hr with the patented Omega shape meter technology manufactured by

More information

In-line diaphragm seal with sterile connection For sanitary applications Model , aseptic connection per DIN 11864

In-line diaphragm seal with sterile connection For sanitary applications Model , aseptic connection per DIN 11864 Diaphragm seals In-line diaphragm seal with sterile connection For sanitary applications Model 981.51, aseptic connection per DIN 11864 WIKA data sheet DS 98.51 Applications For direct, quickly removable

More information

Threaded resistance thermometer Model TR10-C, with fabricated thermowell model TW35

Threaded resistance thermometer Model TR10-C, with fabricated thermowell model TW35 Electrical temperature measurement Threaded resistance thermometer Model TR10-C, with fabricated thermowell model TW35 WIKA data sheet TE 60.03 for further approvals see page 7 Applications Machinery,

More information

Differential Pressure and Flow meters Accessories for the Media Series

Differential Pressure and Flow meters Accessories for the Media Series Differential Pressure and Flow meters Accessories for the Media Series 7 8 9 10 11 6 12 Media 5 Media 6 Media 05 1 5 2 4 Media 4 3 Selection and application These accessories upgrade the devices of the

More information