ISTEC MAGNETIC METERS

Size: px
Start display at page:

Download "ISTEC MAGNETIC METERS"

Transcription

1 ISTEC MAGNETIC METERS MEASURE ANY CONDUCTIVE LIQUIDS OR SLURRIES (EVEN ABRASIVE OR CORROSIVE) WITH THE NEW MICROPROCESSOR-BASED MAGNETIC METER -- A QUALITY PRODUCT - SIMPLE - RELIABLE - AT AN AFFORDABLE PRICE. VISCOSITY, DENSITY AND PRESSURE DO NOT EFFECT THE ACCURACY AND PERFORMANCE. THESE METERS CAN BE INSTALLED HORIZONTALLY OR VERTICALLY, EVEN NEXT TO ELBOWS. THE IDEAL CHOICE FOR A NON-RESTRICTIVE FLOWMETER ADVANCED ENGINEERING DEPENDABILITY HIGH ACCURACY WIDE FLOW RANGE LOW PRICE - GREAT VALUE ANOTHER FINE PRODUCT WITH THE ISTEC TRADEMARK Our Magnetic Meter Line Includes: Series 6000 Flowmeters Series 6100 Flowmeters Series 6200 Flowmeters Series 6300 Flowmeters Series 6400 Flowmeters Series 6910 Converters Series 6920 Converters Series 6930 Converters

2 TECHNICAL SPECIFICATIONS Electromagnetic Flowmeter 6000 Series Description Ideal for measurement of liquids with electrical conductivity and characterized by high accuracy (± ¼%) over a user selectable flow range, simple installation, long service life and ease of maintenance. The meter s accuracy is unaffected by the liquid s physical characteristics (density, temperature, viscosity, ph, etc.) The 6000 Series Electromagnetic Meters Feature: 1/8", ¼", 3/8", ½", and ¾" sizes for flows from 0.1 gpm to 50 gpm The standard pressure is compatible for 225 PSIG services at ambient temperatures or less Designed for liquid temperatures up to 300 F 316 Stainless Steel male NPT threaded ends. NPT Hastelloy or tri-clamp ends optional PTFE liner in stainless steel flow tube Electrode material choices including: 316 stainless steel (standard), Hastelloy B, Hastelloy C, Titanium, Tantalum and Platinum Polished 304 stainless steel coil housing offers excellent water resistance, even when immersed Remote converter installation Converter/ Readout The 6000 Series meters may be coupled with either the 6910 (standard,) 6911, 6920, 6930 or 6931 converter in a remote configuration to power the meter s coils and process created voltage, converting voltage into flow data. The 6930 series is a full featured unit incorporating multiple alarms and multiple output signal choices. The lower cost 6920 is a multi-feature unit including the most customerdesired features, including display, alarm and output choices. Both the 6930 series and 6920 converters incorporate a programmable keypad and on-unit LCD

3 Display. The economical 6910 series converter offers a single choice output with local or remote reading and with or without display. Calibration and Measurement The 6000 meters are Group B1, ISO devices. Every meter is wet calibrated by either a traceable device or primary standard. The maximum accuracy error is given by the following choices: ±.25% when flows are in the user-set 10:1 range of 3 ft/sec to 36 ft/sec ±.50% outside the 10:1 range, for flows between 1 ½ ft/sec and 36 ft/sec Typical Applications Pacing additive chemicals, most acids, strong bases, pharmaceuticals, food and beverage, or most other conductive liquids Series Operating Characteristics and Dimensions Pipe Size (A below) Characteristic/Dimension 1/8" 1/4" 3/8" 1/2" 3/4" Maximum Flow [Qmax] (gpm) at Vmax 36 ft/s Standard Weight (lbs) Standard Length 5 1/8" 5 1/8" 5 1/8" 5 1/8" 5 1/8" Standard Width 3 3/8" 3 3/8" 3 3/8" 3 3/8" 3 3/8" Standard Height 4 ¾" 4 ¾" 4 ¾" 4 ¾" 4 ¾" Connecting NPT Thread Size (NPT) ¼" 3/8" ½" ¾" 1 Overall Dimensions

4 SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE. TECHNICAL SPECIFICATIONS Electromagnetic Flowmeter 6100 Series 6100-Series Electromagnetic Flowmeter Description Ideal for measurement of liquids with electrical conductivity and characterized by high accuracy (± ¼%) over a user selectable flow range, simple installation, long service life and ease of maintenance. The meter s accuracy is unaffected by the liquid s physical characteristics (density, temperature, viscosity, ph, etc.) The 6100 Meter features: 1 ½" to 12" sizes for flows from 8 gpm to 12,700 gpm. Standard pressure compatible with ANSI 150 Ratings. Designed for either rated pressures up to 300 PSI (at ambient temperatures) or liquid temperatures up to 356 F ma Output. Choice of Converters, including 6910 (standard). The 6911, 6930 and 6931 Converters are also available for use with this meter. Choice of Grounding Rings, including 316 SS Grounding Rings (Standard). Hastelloy Grounding rings are also optional with this meter. A PTFE liner in Stainless Steel flow tube. Electrode material choices, including 316 stainless steel (standard), Hastelloy B, Hastelloy C, titanium, tantalum and platinum. Epoxy, double coated coil housing for excellent water resistance, even when immersed. Converter installation options. Reduced dimensions allowing for use with flanges of ANSI 150 and ANSI 300 to 6". Priced below flanged designs. Converter/ The 6100 Series is coupled with a 6910 Converter with a single choice output unit,

5 Readout Installation Requirements Calibration and Measurement available for either local or remote reading. The 6911 converter is also available, with a display. The 6920 and 6930-Series Converters are also available with this meter. These converters are full-featured, incorporating alarms, multiple output signal choices, password protected external keypad and on-unit Liquid Crystal Display. The 6100 Series has no flanges and is installed between pipe flanges and tightened with all-thread rods or long bolts. The 6100 Series is a Group B1, ISO device. Every meter is wet calibrated by either a traceable device or a primary standard. The maximum accuracy error is given by the following choices: ±.25% when flows are in the user-set 10:1 range of 3ft/sec to 36 ft/sec ±.50%, outside the 10:1 range. For flows between 1 ½ ft/sec and 36 ft/sec Typical Applications Raw water, waste water, low concentration slurries, abrasive liquids, pulp & paper, food beverage or most other conductive liquids. Meter Operating Characteristics and Dimensions Pipe Size (D Below) Characteristic/Dimension 1 1/2" 2" 3" 4" 6" 8" 10" 12" Maximum Flow [Qmax](gpm) at Vmax 36ft/s ,400 3,175 5,300 8,800 12,700 Standard Weight (for ANSI 150) (lbs.) Standard Length (for ANSI 150) [A Below] 3.94" 3.94" 5.91" 5.91" 7.09" 7.87" 9.84" 11.81" Standard Width (for ANSI 150) [B Below] 3.5" 4.1" 5.4" 6.2" 8.4" 11.2" 12.8" 14.8" Local Converter Mount [C Below] 1.4" 1.4" 1.4" 1.8" 1.8" 3.3" 3.3" 3.3"

6 Overall Dimensions 6100 Configured for Remote Converter 6100 with Local 6910 Converter 6100 with Local 6920/6931 Converter Horizontal Mounting Vertical Mounting SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE.

7 TECHNICAL SPECIFICATIONS Electromagnetic Flowmeter 6200 Series 6200-Series Electromagnetic Flowmeter Configured for remote reading Description Cost-effective, high accuracy (± ¼%) measurement, over a user-selected flow range, of conductive liquids compatible with the unit s polypropylene liner. The Electromagnetic Flowmeter is characterized by simplified installation, long service life and ease of maintenance. The meter s accuracy is unaffected by the liquid s physical characteristics (density, temperature, viscosity, ph, etc.) The 6200 Series Electromagnetic Flowmeters Feature: 1 ½", 2", 3", 4", and 6" sizes for flows from 8 gpm to 3200 gpm Standard pressure compatible with ANSI 150 ratings Polypropylene (PP) liner in stainless steel flow tube Standard third electrode for liquid grounding Electrode material choices including 316 stainless steel (standard), Hastelloy B, Hastelloy C, titanium, tantalum and platinum Epoxy, double-coated coil housing for excellent water resistance, even when immersed Converter installation options: 6910 (standard), 6911, 6920, 6930 and ma output Reduced dimensions allowing for use with ANSI 150 flanges Full forward and reverse flow capability

8 Priced well below flanged designs Converter/ Readout Installation Requirements Calibration and Measurement The 6200-Series meters may be coupled with 6910 (standard), 6911, 6920, 6930 or 6931 converter in either a local or remote version to power meter and process the created voltage, converting the voltage into flow data. The 6930-Series Converters are full-featured, incorporating multiple alarms, multiple output signal choices, programmable password-protected external keypad and on-unit LCD display. The 6920 Series are multi-featured, including the most user-desired features, including display, alarm and output choices. The lower cost 6910 Series is a single choice output unit. The 6200 Series have no flanges and are installed between the pipe flanges and tightened with all-thread rods or long bolts. The 6200 Series is a Group B1, ISO device. Every meter is wet calibrated by either a traceable device or a primary standard. The maximum accuracy error is given by the following choices: ±.25% when flows are in the user-set 10:1 range of 3 ft/sec to 36 ft/sec ±.50%, outside the 10:1 range, for flows between 1½ ft/sec and 36 ft/sec Typical Applications Raw water, waste water, low concentration slurries, mildly abrasive liquids, and many other conductive liquids compatible with the polypropylene liner. Electromagnetic Flowmeter Operating Characteristics and Dimensions Pipe Size (D below) Characteristic/Dimension 1 ½" 2" 3" 4" 6" Maximum Flow [Qmax] (gpm) at Vmax 36 ft/s Standard Weight (for ANSI 150) (lbs.) Standard Length (for ANSI 150) [A below] Standard Width (for ANSI 150) [B below] 3.9" 3.9" 5.9" 5.9" 7.1" 3.5" 4.1" 5.4" 6.2" 8.4" Converter Stand-off [C below] 1.4" 1.4" 1.4" 1.8" 1.8" Recommended Mating Flanges 2" X 1 1/2" Reducing 3" X 2" Reducing 4" X 3" Reducing 4" ANSI 150 6" ANSI 150 Overall Dimensions 6200 Configured for Remote Converter 6200 with Local 6910 Converter

9 6200 with Local 6920/6931 Converter Horizontal Mounting Vertical Mounting SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE.

10 TECHNICAL SPECIFICATIONS Electromagnetic Flowmeter 6300 Series 6200-Series Electromagnetic Flowmeter Configured for remote reading Description Ideal for measurement of liquids with electrical conductivity and characterized by high accuracy (± ¼%) over a user selected flow range, simple installation, long service life and ease of maintenance. Th meter s accuracy is unaffected by the liquid s physical characteristics (density, temperature, viscosity, ph, etc.) The 6300 Series Electromagnetic Flowmeters feature: 10", 12", 14", 16", 18", 20", 24", 30", 36" and 42" sizes for flows from 490 gpm to 155,000 gpm Standard pressure compatible with ANSI 150 ratings Designed for rated pressures up to 300 PSI (at ambient temperatures) or liquid temperatures up to 200 F Epoxy coated carbon steel or optional 304 stainless steel flanges to 16" diameter Hard rubber liner in stainless steel flow tube Electrode material choices including 316 stainless steel (standard), Hastelloy B, Hastelloy C, titanium, tantalum and platinum Epoxy, double coated coil housing offering excellent water resistance, even when immersed for short periods of operation Flexible converter installation 4 20 ma output Full bi-directional flow capacity Converter/ Readout The 6300 Series may be coupled with our 6910 (standard), 6911, 6920, 6930 or 6931 converters in either a local or a remote version. These converters power the meter coils and process created voltage, converting voltage into flow data. The 6930 Series converters are full featured units incorporating multiple alarms and output signal choices. The lower cost 6920 converter is a multi-feature unit including the most customer-desired features, including display, alarm and output choices. Both

11 the 6930 Series and 6920 converters incorporate a programmable external keypad and on-unit LCD Display. The economical 6910 Series converters offer a single choice of output with on-unit or remote programming and with or without display. Installation Requirements Calibration and Measurement When installed in an insulating pipe the two grounding rings provided should be inserted between the gasket surfaces and pipe flanges both upstream and downstream. The 6300 Series meters are Group B1, ISO devices. Every meter is wet calibrated by either a traceable device or primary standard. The maximum accuracy error is given by the following choices: ±.25% when flows are in the user-set 10:1 range of 3 ft/sec to 36 ft/sec ±.50% outside the 10:1 range, for flows between 1 ½ft/sec and 36 ft/sec Typical Applications Raw water, waste water, low concentration slurries, abrasive liquids, pulp & paper, food & beverage, or most other conductive liquids. Electromagnetic Flowmeter Operating Characteristics and Dimensions Pipe Size (C below) Characteristic/Dimension 10" 12" 14" 16" 18" 20" 24" 30" 36" 42" Maximum Flow [Qmax] at Vmax 36 ft/sec Coil Housing Width [A below] 14.0" 17.5" 18.7" 20.7" 24.2" 26.2" 32.6" 41.3" 43.9" 48.4" Coil Housing Height [B below] 16.1" 18.5" 20.9" 23.0" 24.6" 27.8" 32.6" 41.3" 43.9" 48.4" ANSI 150PSI Flanges Flange Diameter [D below] 15.6" 17.5" 19.9" 22.2" 24.2" 26.4" 30.7" 40.0" 43.9" 48.4" Length [E below 11.8" 11.8" 19.8" 15.7" 17.7" 19.7" 23.6" 31.5" 35.4" 39.4" Weight (pounds) Number of Bolts ANSI 300 PSI Flanges Flange Diameter [D below] 16.7" 19.1" 21.9" 24.4" 26.4" 28.7" 33.3" NA NA NA Length [E below] 11.8" 13.8" 15.7" 21.7" 23.6" 23.6" 23.6" NA NA NA Weight (pounds) NA NA NA Number of Bolts NA NA NA

12 Overall Dimensions 6300 Series Configure d for Remote Reading 6300 Series with Local 6910 Converter SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE.

13 TECHNICAL SPECIFICATIONS Electromagnetic Flowmeter 6400 Series 6400-Series with 6910 Converter Description Ideal for measurement of liquids with electrical conductivity and characterized by high accuracy (± 1/4%) over a user selectable range, simple installation, long service life and ease of maintenance. The meter s accuracy is unaffected by the liquid s physical characteristics (density, temperature, viscosity, ph, etc.) The 6400-Series Electromagnetic Flowmeter features: 1", 1 ½", 2", 3", 4", 6" and 8" sizes for flows from 5 GPM to 5300 GPM The standard pressure is compatible with ANSI 150ratings Designed for rated pressures up to 900 PSI (at ambient temperatures) or liquid temperatures up to 356 F Epoxy coated carbon steel or optional 304 stainless steel flanges PTFE liner in a stainless steel flow tube (8" standard with hard rubber liner) Electrode material choices: 316 stainless steel (standard), Hastelloy B, Hastelloy C, titanium, tantalum and platinum Double coated epoxy coil housing offers excellent water resistance, even when immersed Converter installation options: 6910(standard), 6911, 6920, 6930 and 6931 Converter/ Readout Installation Requirements The 6400-Series may be coupled with either the 6910(standard), 6911, 6920, 6930 or Readout 6931 converter in either a local or a remote version. The 6930 converter is full-feaured; Incorporating multiple alarms and output signal choices. The lower cost 6920 converter is a multi-feature unit including the most customer-desired features, including display, alarm and output choices. Both the 6920 and 6931 converters incorporate a programmable external keypad and on-unit LCD Display. The 6911 converter is very economical and offers the same features as the 6910 converter, but with a display. When installed in an insulating pipe, the meter should either be ordered with the optional third grounding electrode or two liquid grounding rings should be inserted

14 between the gasket surfaces and pipe flanges, both upstream and downstream. Calibration and Measurement The 6400 meters are Group B1, ISO devices. Every meter is wet calibrated by either a traceable device or a primary standard. The maximum accuracy error is given by the following choices: ±.25% when flows are in the user-set 10:1 range of 3ft/sec to 36 ft/sec ±.50%, outside of the 10:1 range, for flows between 1 ½ ft/sec and 36 ft/sec Typical Applications Raw water, waste water, low concentration slurries, abrasive liquids, pulp & paper, food & beverage or most other conductive liquids Series - Operation Characteristics and Dimensions Pipe Size (C below) Characteristic Dimension 1" 1 1/2" 2" 3" 4" 6" 8" Maximum Flow [Qmax] (GPM) at Vmax36ft/s Standard Weight (for ANSI 150) (lbs.) Standard Length (for ANSI 150) [A below] 7.9" 7.9" 7.9" 10.6" 10.6" 11.8" 11.8" Standard Width (for ANSI 150) [B below] 4.6" 6.5" 6.5" 8.8" 8.8" 12.3" 13.6" Number of Bolts (for ANSI 150)

15 Local Meter Version with 6920/6931 Converter Remote Meter Version Vertical Mounting Horizontal Mounting SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE.

16 TECHNICAL SPECIFICATIONS Electromagnetic Flowmeter 6910 Series Converters Remote 6911 Converter Description: The 6910-Series Converters are minimum feature, cost-effective converters that power the Electromagnetic Flowmeter and process created voltage, converting the voltage into flow data. Flow data is then either transmitted to another device (6910/6911) or displayed on the unit with Liquid Crystal Display (6911.) 6910-Series Converter Features: Compatible with all of our Electromagnetic Flowmeters Local Models for liquid temperatures up to 200 F. Remote converter for use with meter configurations up to 356 F Programmable choice of single output including totalization, scaleable 0 1 khz frequency, maximum or minimum flow alarm, empty pipe alarm, hardware failure alarm, automatic scale change or direct or reverse flow rate ma output RS485 interface for network connections Designed for use in ambient temperatures ranging from -4 F to 140 F Pressure die-cast aluminum case featuring IP65 protection Local or Remote mounting choices LCD Display available on 6911 models

17 6910 Series Dimensions SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE.

18 TECHNICAL SPECIFICATIONS Electromagnetic Flowmeter 6920 Series Converters Remote 6920 Converter Description: The 6920 Converter is a multi-feature, multiple output, user-programmable converter incorporating the most common user-preferred features and output. The 6920 Converter powers the Electromagnetic Flowmeter Sensor coils and processes created voltage, converting that voltage into flow data. Flow data can be transmitted to another device and/or displayed on the unit. Standard 6920 Converter Features: Compatible with all of our Electromagnetic Flowmeters Available for either local or remote reading Temperature range: -4 F to 140 F ambient Accuracy (Maximum): ± 0.50%, at a range of 10:1, for flows between 1 ½ ft/sec to 36 ft/sec Repeatability: ± 0.1% Die-cast aluminum IP67-rated case Display: Two line 16-Character display Keypad: Easy access 6-key front panel for programming and display control Data Display Flow rate: Engineering units or Percent or Full Scale Volume: total forward flow, total reverse and partial forward and reverse flows (partial totalizers can be used to determine net forward and reverse flows. Alarms, choice of one: Empty pipe, overflow, underflow, hardware problems Flow direction Programming Levels View only: no configuration or alarm changes Level 1(basic configuration): password protected configuration changes Level 2: password protected changes to all configuration parameters and alarms Outputs Flow rate: 4-20 ma output to a maximum load of 1000 ohms or Frequency

19 Hz Volume: 24 VDC pulse output, user scaled to standard measurement Power Supply 90 to 264 volt, 45/66 Hz keyboard-selected or 16 to 28 VAC, Hz, or VDC Power consumption: 3 to 17 watts, depending on Electromagnetic Flowmeter size SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE.

20 TECHNICAL SPECIFICATIONS Electromagnetic Flowmeter 6930 Series Converters Remote 6931 Converter Description The 6930 Converters are full-featured, multiple-output, user-programmable converters that feature second-generation micro-electronics for lower power operation and enhanced capability. The 6930 Converters power the Electromagnetic Flowmeter coils and process created voltage, converting that voltage into flow data. Flow data can be transferred to another device and/or displayed on the unit. Standard features of the 6930 Converter include: Available for either local or remote reading Designed for use in ambient temperatures ranging from -4 F to 140 F Maximum accuracy error is given by the following: ± 0.25% when flows are in the user-set 10:1 range of 3 ft/sec to 36 ft/sec. ± 0.50%, outside the 10:1 range, for flows between 1 ½ ft/sec. And 36 ft/sec. Automatic flow range adjustment providing maximum accuracy through full available flow range Automatic empty pipe detection and totalizer cut-off Standard choice of one output alarm: minimum or maximum flow rate, empty pipe, reverse flow or overflow/automatic scale change alarm User set low flow cut-off from 0 to 25% of full scale value 4-20 ma output to a maximum load of 1000 ohms Configurable choice of khz digital output Galvanically insulated outputs

21 SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE.

Electromagnetic Flowmeters. Product Overview.

Electromagnetic Flowmeters. Product Overview. Electromagnetic Flowmeters Product Overview www.lcmeter.com Premier products, premier performance Liquid Controls offers a broad selection of electromagnetic (Mag) flow meters for industrial and water

More information

Product Data Sheet 2012 Rev 5 FLOWMETRIX SA SAFMAG Electromagnetic Flowmeter Doc Date

Product Data Sheet 2012 Rev 5 FLOWMETRIX SA SAFMAG Electromagnetic Flowmeter Doc Date FLOWMETRIX SA Doc Date 17.07.2012 PERFORMANCE * 0,5% of rate (Standard) * 0,25% of rate (Optional) * 1000 : 1 operable flow range * Excellent repeatability * Optional Bi-directional measurement * Advanced

More information

TEK-F LUX 1400A. Electromagnetic Flowmeter. Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys FLOW

TEK-F LUX 1400A. Electromagnetic Flowmeter.  Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys FLOW Technology Solutions TEK-F LUX 1400A Electromagnetic Flowmeter FLOW www.tek-trol.com Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys Introduction Electromagnetic flowmeters are also

More information

Magnetic-inductive flow meter EPS / UMF2. Technical data sheet

Magnetic-inductive flow meter EPS / UMF2. Technical data sheet Magnetic-inductive flow meter EPS / UMF2 Technical data sheet high accuracy: 0.3 % of actual maintenance-free no pressure drop numerous lining materials numerous electrode materials low-cost grounding

More information

Electromagnetic Flow Meter Owner s Manual HARDWARE

Electromagnetic Flow Meter Owner s Manual HARDWARE Electromagnetic Flow Meter Owner s Manual HARDWARE Compact Magnetic Flowmeter (Flange Connection) Sanitary Magnetic Flowmeter (Tri clamp Connection) Part No. 910000 Rev.C Content 1. GENERAL INFORMATION...2

More information

Flow Measurement & Control Solutions

Flow Measurement & Control Solutions BTU Meters Flow Meters Remote Displays Radiator Valves Balancing Valves Flow Measurement & Control Solutions TABLE OF CONTENTS BTU Meters 4000 Series...3 Chip Card System 5000 Series...4 Super Jet Water

More information

Magnetic Inductive Flowmeter EP / UMF2 (B)

Magnetic Inductive Flowmeter EP / UMF2 (B) Magnetic Inductive Flowmeter EP / UMF2 (B) High accuracy 0.3 % of reading No maintenance required no pressure drop different lining materials different electrode materials inexpensive earthing electrode

More information

F-1500 SERIES INSERTION TURBINE FLOW METER FEATURES Belcher Road South, Largo, FL USA Tel +1 (727) Fax +1 (727)

F-1500 SERIES INSERTION TURBINE FLOW METER FEATURES Belcher Road South, Largo, FL USA Tel +1 (727) Fax +1 (727) F-1500 SERIES INSERTION TURBINE FLOW METER Insertion turbine flow meters are ideal for use in larger steam lines where downsizing the line size to improve flow measurement is not desirable. In these applications,

More information

Electromagnetic flowmeters Series FLOMID Electromagnetic flowmeter for conductive liquids

Electromagnetic flowmeters Series FLOMID Electromagnetic flowmeter for conductive liquids Electromagnetic flowmeters Series FLOMID Electromagnetic flowmeter for conductive liquids Flow rate measurement is independent of density, temperature, viscosity and pressure Pulsed coil excitation to

More information

F-2700 SERIES INSERTION VORTEX FLOW METER

F-2700 SERIES INSERTION VORTEX FLOW METER F-2700 SERIES INSERTION VORTEX FLOW METER CALIBRATION Every ONICON flow meter is wet calibrated in a flow laboratory against standards that are directly traceable to N.I.S.T. A certificate of calibration

More information

The Polaris MA1 is the first liquid flow meter offered by Magnetrol, expanding the already diverse level and flow measurement portfolio that has been

The Polaris MA1 is the first liquid flow meter offered by Magnetrol, expanding the already diverse level and flow measurement portfolio that has been The Polaris MA1 is the first liquid flow meter offered by Magnetrol, expanding the already diverse level and flow measurement portfolio that has been established over the last 80 years. The electromagnetic

More information

F-2700 SERIES INSERTION VORTEX FLOW METER

F-2700 SERIES INSERTION VORTEX FLOW METER F-2700 SERIES INSERTION VORTEX FLOW METER APPLICATIONS Saturated steam Hot water to 500 F (260 C) standard 750 F (400 C) optional Applications with optional pressure sensor Superheated steam to 500 F (260

More information

유량계전문제조업체. Electro Magnetic FLOWMETER

유량계전문제조업체. Electro Magnetic FLOWMETER 유량계전문제조업체 w w w. f c k o r e a i n s. c o m Electro Magnetic FLOWMETER ELECTRO-MAGNETIC FLOW METER Contents Principle of Operation 04 Grounding Method 05~07 Piping Installation 08 CN-400 CNT-2 Flanged

More information

Magnetic-inductive flow meter for hazardous areas

Magnetic-inductive flow meter for hazardous areas Magnetic-inductive flow meter for hazardous areas Technical Datasheet EPX / UMF3 high accuracy: 0.3 % of actual maintenance-free no pressure drop numerous lining materials numerous electrode materials

More information

F-1500 SERIES INSERTION TURBINE FLOW METER

F-1500 SERIES INSERTION TURBINE FLOW METER F-1500 SERIES INSERTION TURBINE FLOW METER APPLICATIONS Saturated steam Hot water to 450 F (232 C) standard 850 F (454 C) optional Applications with optional pressure sensor Superheated steam to 450 F

More information

Field IT Electro-Magnetic Flowmeters Sensors

Field IT Electro-Magnetic Flowmeters Sensors Data Sheet Field IT Electro-Magnetic Flowmeters Sensors MagMaster MFE Unrivalled flow performance ±0.2% accuracy. Pulsed DC Technology Incorporates Benefits of AC Systems Operable flow range of 1000:1.

More information

ABB Instrumentation. MagMaster MFE Series Electromagnetic Sensors. Specifications. MagMaster - bringing unsurpassed flowmetering performance

ABB Instrumentation. MagMaster MFE Series Electromagnetic Sensors. Specifications. MagMaster - bringing unsurpassed flowmetering performance Specifications MagMaster MFE Series Electromagnetic Sensors nn Unrivalled flow performance ±0.2% accuracy. nn Pulsed DC Technology Incorporates Benefits of AC Systems nn Operable flow range of 1000:1.

More information

EPS / UMF2. Magnetic Inductive Flowmeter for Conductive Liquids

EPS / UMF2. Magnetic Inductive Flowmeter for Conductive Liquids Magnetic Inductive Flowmeter for Conductive Liquids measuring monitoring analyzing EPS / UMF2 High Accuracy: 0.3 % of Actual Flow Maintenance-free No Pressure Drop Wide Variety of Lining and Electrode

More information

Rosemount 8750WA Magnetic Flowmeter System For Water and Wastewater Industries

Rosemount 8750WA Magnetic Flowmeter System For Water and Wastewater Industries Product Data Sheet January 214 813-1-475, Rev FA Rosemount 875WA Magnetic Flowmeter System For Water and Wastewater Industries THE 875WA MAGNETIC FLOWMETER Rosemount reliability in a customized offering

More information

RCM - Direct Reading Flowmeters

RCM - Direct Reading Flowmeters Compact Design Easy to Install Horizontal or Vertical Installation Flow Rates up to 3000 GPM (Liquid) or 20000 SCFM (Gas) Low Pressure Drop Optional Alarms and Output Signals Accuracy: ± 3% of full scale

More information

G2 Industrial Grade Meters

G2 Industrial Grade Meters G2 Industrial Grade Meters The unique modular approach of the Industrial Grade Meter line allows you to section 2: g2 industrial grade meters design a meter to match your specific application. Turbine

More information

F-2600 SERIES INLINE VORTEX FLOW METER

F-2600 SERIES INLINE VORTEX FLOW METER F-2600 SERIES INLINE VORTEX FLOW METER APPLICATIONS Saturated steam Hot water to 500 F (260 C) standard 750 F (400 C) optional Applications with optional pressure sensor Superheated steam to 500 F (260

More information

Isoil Industria a worldwide supplier of electromagnetic flowmeters Total flow control. Accurate to the drop.

Isoil Industria a worldwide supplier of electromagnetic flowmeters Total flow control. Accurate to the drop. www.isomag.eu Isoil Industria a worldwide supplier of electromagnetic flowmeters Total flow control. Accurate to the drop. 1 THE IDEAL FLOWMETERS FOR ANY APPLICATION from DN03 to DN2400 wide range of process

More information

UniMag DT Series Electromagnetic Flow Tubes

UniMag DT Series Electromagnetic Flow Tubes Description Spirax Sarco s UniMag DT Magnetic Flow Meter System consists of the patented UniMag Flow Tube and EFT10 Flow Transmitter. UniMag sensors are unique because they do not require a liner and can

More information

Electro-Magnetic Flowmeters Sensors MagMaster MFE

Electro-Magnetic Flowmeters Sensors MagMaster MFE Data Sheet (US) Electro-Magnetic Flowmeters Sensors MagMaster MFE Unrivalled flow performance ±0.2% accuracy. Pulsed DC Technology Incorporates Benefits of AC Systems Operable flow range of 1000:1. Two-year

More information

EGM1100C MAGMAX. Compact Electromagnetic Flowmeter GENERAL FEATURES STANDARD SPECIFICATION. General Specification

EGM1100C MAGMAX. Compact Electromagnetic Flowmeter GENERAL FEATURES STANDARD SPECIFICATION. General Specification EGMC Compact Electromagnetic Flowmeter GENERA MAGMAX EGMC is the compact type electromagnetic flowmeter with a converter EGC mounted integrally on a primary head EGS lined with fluorocarbon resin PFA.

More information

Options guide. Electromagnetic flowmeters. M9xx

Options guide. Electromagnetic flowmeters. M9xx Options guide Electromagnetic flowmeters M9xx Ordering codes Model Description M 910 -V0 0 0 0 DN50 PN16 Example Sensor M Basic Ex Ex certified (remote version only) Transmitter 910E Economic version 910

More information

MEASURE TODAY. ENSURE TOMORROW. SpireMag Series T-MAG Electromagnetic BTU Meter

MEASURE TODAY. ENSURE TOMORROW. SpireMag Series T-MAG Electromagnetic BTU Meter MEASURE TODAY. ENSURE TOMORROW. SpireMag Series T-MAG Features The T-MAG BTU meter is the latest addition to the SpireMag series for accurate thermal energy measurement. It utilizes a high accuracy electromagnetic

More information

ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products Rev PK KMS501W & KMS502F- TW. Electromagnetic TRADEWASTE Flowmeters FEATURES:

ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products Rev PK KMS501W & KMS502F- TW. Electromagnetic TRADEWASTE Flowmeters FEATURES: KMS501W & KMS502F- TW FEATURES: Fitted with Sydney Water Tradewaste plugs (Sampler and ma outputs). For waste water, bore water and irrigation ( upto 10% solids). Unsurpassed accuracy to ±0.5% 0.5 m/s

More information

Appendix. Clearance. Skewed profiles. Application Schematics

Appendix. Clearance. Skewed profiles. Application Schematics Appendix Application Schematics The purpose of the application schematics is to show different applications and the best sensor location for a particular application. Clearance Because the sensor will

More information

PanaFlow MV80. In-line Multivariable Flowmeter for Mass, Temperature, and Pressure. GE Sensing. Applications. Key Benefits

PanaFlow MV80. In-line Multivariable Flowmeter for Mass, Temperature, and Pressure. GE Sensing. Applications. Key Benefits Key Benefits Multivariable vortex flowmeter for measuring volumetric flow, temperature, pressure, density, and mass flow using a single meter Measures most gases, liquids and steam without the need to

More information

Full Profile Insertion

Full Profile Insertion FPI Mag Meter Full Profile Insertion High Performance Electromagnetic Flow Meter Municipal Market Product Presentation Manufactured exclusively by McCrometer, Inc. Hemet, CA USA 55+ Years of Experience

More information

DW PADDLE-BELLOWS FLOWMETER & SWITCH

DW PADDLE-BELLOWS FLOWMETER & SWITCH DW PADDLE-BELLOWS FLOWMETER & SWITCH Flow Pressure Level Temperature measurement monitoring control S3 Accuracy: ±3% Full Scale Excellent for Highly Contaminated Media Orientation Independent Brass or

More information

SHENITECH, LLC

SHENITECH, LLC SHENITECH, LLC Features and Benefits 100-H Tower Office Park, Woburn, MA 01801 Mag888 Electromagnetic Flow Converter The Mag888 flow converter is used together with the Mag888 flow sensor to form a complete

More information

DW PADDLE-BELLOWS FLOWMETER & SWITCH

DW PADDLE-BELLOWS FLOWMETER & SWITCH DW PADDLE-BELLOWS FLOWMETER & SWITCH Flow Pressure Level Temperature measurement monitoring control Accuracy: ±% Full Scale Excellent for Highly Contaminated Media Orientation Independent Brass or Stainless

More information

DW PADDLE-BELLOWS FLOWMETER & SWITCH

DW PADDLE-BELLOWS FLOWMETER & SWITCH DW PADDLE-BELLOWS FLOWMETER & SWITCH Flow Pressure Level Temperature measurement monitoring control S3 Accuracy: ±3% Full Scale Excellent for Highly Contaminated Media Orientation Independent Brass or

More information

Abridged Specifications: 10D1477 Electrodeless Sensor with 50XM1000 Transmitter

Abridged Specifications: 10D1477 Electrodeless Sensor with 50XM1000 Transmitter Abridged Specifications: 10D1477 Electrodeless Sensor with 50XM1000 Transmitter The 10D1477 electrodeless ceramic lined wafer sensors and 50XM1000 transmitters are pulsed DC magnetic flowmeters. These

More information

Rosemount 8750WB Magnetic Flowmeter System

Rosemount 8750WB Magnetic Flowmeter System Rosemount 8750WB Magnetic Flowmeter System for Utility, Water, and Wastewater Applications Product Data Sheet 00813-0200-4750 Rev AA THE 8750W MAGNETIC FLOWMETER Rosemount reliability customized for Water,

More information

EGM5300C MAGMAX. Compact Electromagnetic Flowmeter GENERAL FEATURES STANDARD SPECIFICATION. General Specification

EGM5300C MAGMAX. Compact Electromagnetic Flowmeter GENERAL FEATURES STANDARD SPECIFICATION. General Specification MAGMAX EGM53C Compact Electromagnetic Flowmeter GENERAL MAGMAX EGM53C is a combination of EGS5 primary head with Ceramic measuring tube and high performance converter EGC3. EGM53C with high durability

More information

Electromagnetic flowmeters Series FLOMAT Insertion electromagnetic flowmeter for conductive liquids

Electromagnetic flowmeters Series FLOMAT Insertion electromagnetic flowmeter for conductive liquids Electromagnetic flowmeters Series FLOMAT Insertion electromagnetic flowmeter for conductive liquids For use in large diameter pipes as an economical solution for flow measurement Flow rate measurement

More information

SITRANS F M flow sensors 711/A and 711/911E

SITRANS F M flow sensors 711/A and 711/911E s flow sensors 711/A and 711/911E flow sensors 711/A and 711/911E Introduction Application Mode of operation, operation Mode of operation All electromagnetic flow measurements are based on Faraday s Law

More information

From. McCROMETER, INC WEST STETSON AVENUE HEMET, CA Phone (951) Toll Free (800) Fax (951)

From. McCROMETER, INC WEST STETSON AVENUE HEMET, CA Phone (951) Toll Free (800) Fax (951) SPI Mag MODEL 282L SINGLE POINT INSERTION ELECTROMAGNETIC FLOW METER 2 SENSOR SUBMITTAL PACKAGE From McCROMETER, INC. 3255 WEST STETSON AVENUE HEMET, CA 92545 Phone (951) 652-6811 Toll Free (800) 220-2279

More information

PMG MAGNETIC FLOWMETER

PMG MAGNETIC FLOWMETER PMG MAGNETIC FLOWMETER Flow Pressure Level Temperature measurement monitoring control Flow Ranges 0.015-0.5 Through 350-10600 GPM 1/2 to 12 Sizes Accuracy ±0.5% or ±0.25% of Reading Viscosity and Density

More information

PROCESSAUTOMATIC MAGNETIC FLOWMETER

PROCESSAUTOMATIC MAGNETIC FLOWMETER PROCESSAUTOMATIC MAGNETIC FLOWMETER SWEDEN The PROCESSAUTOMATIC magnetic flowmeter is suitable for most hygienic applications as all wetted parts are made of food grade stainless steel or teflon and most

More information

A1 Commercial Grade Meters

A1 Commercial Grade Meters A1 Commercial Grade Meters Commercial Grade Meters are designed as self-contained, battery powered units. These indicating meters come in Aluminum or Nylon only. A1 Meters are not field serviceable like

More information

Pro-V Multivariable Flowmeter Model M24 In-line Vortex

Pro-V Multivariable Flowmeter Model M24 In-line Vortex Pro-V Multivariable Flowmeter Model M24 In-line Vortex Pro-V TM Advantage: VorTek Instruments Pro-V multivariable flowmeters utilize three primary sensing elements a vortex shedding velocity sensor, an

More information

Electromagnetic amplifier Primo Advanced for all detectors

Electromagnetic amplifier Primo Advanced for all detectors Electromagnetic amplifier Primo dvanced for all detectors Features ccuracy ±0,25% Flow range 0,03 12 m/s 6 2000 LC display Power supply 85 2 VC / 24 VC escription imensions The amplifier type Primo dvanced

More information

Models ADMAG AXF and ADMAG CA Sanitary 3A Compliant Integral and Remote Magnetic Flowmeters

Models ADMAG AXF and ADMAG CA Sanitary 3A Compliant Integral and Remote Magnetic Flowmeters General Specifications Models and ADMAG CA Sanitary 3A Compliant Integral and Remote Magnetic Flowmeters ADMAG and ADMAG CA 3A & FDA compliant magnetic flowmeters are dependable and reliable instruments

More information

Vortex In Line Flow Meter

Vortex In Line Flow Meter Principles of Operation Vortices are created when a fluid passes around a bluff body as shown below. Vortices are alternately shed on each side of the body, 0 degrees out of phase to each other, resulting

More information

E M F. Description. Principle of Operation. Introduction for EMF Series of Electromagnetic Flowmeters

E M F. Description. Principle of Operation. Introduction for EMF Series of Electromagnetic Flowmeters EMF Series ELECTROMAGNETIC FLOWMETER Description Introduction for EMF Series of Electromagnetic Flowmeters The Electromagnetic Flowmeters(EMF) can be used to accurately measure the flowrate of liquids,

More information

RCM. Direct Reading Flowmeter. for Liquids or Gases

RCM. Direct Reading Flowmeter. for Liquids or Gases Direct Reading Flowmeter for Liquids or Gases measuring monitoring analyzing RCM Compact Design Easy to Install Horizontal or Vertical Installation Flow Rates up to 3000 GPM (Liquid) or 20000 SCFM (Gas)

More information

METAL VAREA-METER STRAIGHT THROUGH TYPE ROTAMETER

METAL VAREA-METER STRAIGHT THROUGH TYPE ROTAMETER TECHNICAL INFORMATION METAL VAREA-METER STRAIGHT THROUGH TYPE ROTAMETER Electronic Transmitter INTRODUCING THE METAL TUBE VAREA-METER U.S. Filter/Wallace & Tiernan Products straight through metal tube

More information

SENSOR MUT2300. Electromagnetic flowmeter. The electromagnetic flowmeter designed for the toughest applications DS401-1-USA

SENSOR MUT2300. Electromagnetic flowmeter. The electromagnetic flowmeter designed for the toughest applications DS401-1-USA SENSOR MUT2300 Electromagnetic flowmeter The electromagnetic flowmeter designed for the toughest applications DS401-1-USA Sensor MUT2300 The MUT2300 sensors represent the state of the art of Euromag International

More information

mass flowmeter for compressed air

mass flowmeter for compressed air mass flowmeter for compressed air VARIOMASS LC pressure and temperature compensated flowmeter easy and cost effective installation of the senor no pressure loss caused by the sensor no moving parts, i.e.

More information

mass flowmeter for compressed air

mass flowmeter for compressed air mass flowmeter for compressed air VARIOMASS ECO pressure and temperature compensated easy and cost effective installation of the sensor no pressure loss caused by the sensor no moving parts, i.e. maintenance

More information

VIM20 Vortex Insertion Flowmeter

VIM20 Vortex Insertion Flowmeter VIM20 Principle of Operation Vortex flowmeters measure flows of liquid, gas and steam by detecting the frequency at which vortices are alternately shed from a bluff body. According to proven laws of physics,

More information

F-2600 SERIES INLINE VORTEX FLOW METER

F-2600 SERIES INLINE VORTEX FLOW METER F-2600 SERIES ININE VORTEX FOW METER APPICATIONS Saturated steam Hot water to 500 F (260 C) standard 750 F (400 C) optional Applications with optional pressure sensor Superheated steam to 500 F (260 C)

More information

Models ADMAG AXF and ADMAG CA Sanitary 3A Compliant Integral and Remote Magnetic Flowmeters

Models ADMAG AXF and ADMAG CA Sanitary 3A Compliant Integral and Remote Magnetic Flowmeters General Specifications Models and ADMAG CA Sanitary 3A Compliant Integral and Remote Magnetic Flowmeters ADMAG and ADMAG CA 3A & FDA compliant magnetic flowmeters are dependable and reliable instruments

More information

TYPE MP OSCILLATING PISTON FLOWMETER

TYPE MP OSCILLATING PISTON FLOWMETER TS-150 (G) TYPE MP OSCILLATING PISTON FLOWMETER Flow Rates of 3.8 to 1,140 Liters/Min. (1 to 300 gpm) Accuracy of ±0.5% of Rate ±0.1% Repeatability Magnetically Coupled Output Shaft Proven Reliable Oscillating

More information

Time Delta S Fixed Transit-Time Flow Meter System

Time Delta S Fixed Transit-Time Flow Meter System Fixed Transit-Time Flow Meter System Key Features Dynamic flow correction Simple configuration Digital outputs Enhanced anti-bubble measurement technology (ABM) Rugged and reliable Maintenance free The

More information

KDM ARMORED FLOW METER & SWITCH

KDM ARMORED FLOW METER & SWITCH KDM ARMORED FLOW METER & SWITCH Flow Pressure Level Temperature measurement monitoring control S2 Short Installation Length SS, PTFE or Hastelloy Wetted Parts Analog Output Available 110 F to + 390 F Temperature

More information

ProcessAutomatic EZ-Mag

ProcessAutomatic EZ-Mag ProcessAutomatic EZ-Mag THE EZ-CHOICE Robust Design: The highly robust and compact EZ-Mag is designed to be able to cope with tough environments. Whether installed in-house or on a vehicle, you can be

More information

HG5 Series. Metal Tube Rotameter CATALOG MAIN FEATURES TECHNICAL PARAMETERS

HG5 Series. Metal Tube Rotameter CATALOG MAIN FEATURES TECHNICAL PARAMETERS H5 Series Metal Tube Rotameter H5 series metal tube rotameter (also called variable area flow meter) is a kind of measuring meter which the flow rate is changing along with the area and is widely used

More information

SENSOR MUT2400EL. Electromagnetic flowmeter. The electromagnetic flowmeter designed for food industry DS200-1-ENG

SENSOR MUT2400EL. Electromagnetic flowmeter. The electromagnetic flowmeter designed for food industry DS200-1-ENG The electromagnetic designed for food industry DS200-1-ENG The is specifically designed for use in the food processing industry. It is made of materials approved by international regulations, compatible

More information

Armstrong In-Line and Insertion Vortex Flow Meters

Armstrong In-Line and Insertion Vortex Flow Meters Armstrong In-Line and Insertion Vortex Flow Meters Designs, materials, weights and performance ratings are approximate and subject to change without notice. Visit for up-to-date information. 1 In-Line

More information

Electromagnetic amplifier type ModMAG M10 for all detectors

Electromagnetic amplifier type ModMAG M10 for all detectors Badger Meter Europa GmbH Nürtinger Str. 76 72639 Neuffen (Germany) Tel. +49-7025-9208-0 Fax +49-7025-9208-15 www.badgermeter.de badger@badgermeter.de Electromagnetic amplifier type ModMG M10 for all detectors

More information

FLS F6.60 MAGMETER FLOW SENSOR INSERTION FLOW SENSORS APPLICATIONS MAIN FEATURES

FLS F6.60 MAGMETER FLOW SENSOR INSERTION FLOW SENSORS APPLICATIONS MAIN FEATURES FLS F6.60 MAGMETER FLOW SENSOR The new F6.60 and F6.63 are flow meters without moving mechanical parts which can be applied for the measurement of dirty liquids so long as they are conductive and homogeneous.

More information

VersaFlow Vortex 100 Vortex Flow Meter Specifications

VersaFlow Vortex 100 Vortex Flow Meter Specifications VersaFlow Vortex 100 Vortex Flow Meter Specifications 34-VF-03-05 May 2011 The All-In-One Solution The VERSAFLOW is the only vortex flowmeter with integrated and temperature compensation in 2- wire technology.

More information

Paddle-wheel flow controller for On/Off control

Paddle-wheel flow controller for On/Off control Paddle-wheel flow controller for On/Off control Type 803 can be combined with... Indication, monitoring, transmitting and On/Off control in one device Programmable s (transistor or relay) Automatic-calibration:

More information

EM101 LOW FLOW MAGNETIC FLOWMETER INSTRUCTIONS

EM101 LOW FLOW MAGNETIC FLOWMETER INSTRUCTIONS Spec Tech Industrial 203 Vest Ave. Valley Park, MO 63088 Phone: 888 SPECTECH Email: sales@spectechind.com www.spectechind.com EM101 EM101 LOW FLOW MAGNETIC FLOWMETER INSTRUCTIONS LOW FLOW MAGNETIC FLOWMETER

More information

WaterMAG. Electromagnetic Flowmeter for Water Applications. Model MCB10A OVERVIEW APPLICATIONS FEATURES. No. SS2-MCB

WaterMAG. Electromagnetic Flowmeter for Water Applications. Model MCB10A OVERVIEW APPLICATIONS FEATURES. No. SS2-MCB WaterMAG Electromagnetic Flowmeter for Water Applications OVERVIEW The WaterMAG is an electromagnetic flowmeter for water measurement applications based on field proven Azbil Corporation's technologies.

More information

MagneW Neo+ Two-wire Electromagnetic Flowmeter Integral type TIIS Explosion-protected Apparatus

MagneW Neo+ Two-wire Electromagnetic Flowmeter Integral type TIIS Explosion-protected Apparatus MagneW Neo+ Two-wire Electromagnetic Flowmeter Integral type TIIS Explosion-protected Apparatus OVERVIEW The MagneW Neo+ is a high performance two wired electromagnetic flowmeter based on field proven

More information

F-2500 SERIES VORTEX METER

F-2500 SERIES VORTEX METER F-500 SERIES VORTEX METER APPLICATIONS Saturated steam Hot water to F (0 C) Applications with optional pressure sensor Superheated steam to F (0 C) Compressed air Industrial gases CALIBRATION Each meter

More information

Vortex In Line Flow Meter

Vortex In Line Flow Meter Vortex In Line Flow Meter Principles of Operation Vortices are created when a fluid passes around a bluff body as shown below. Vortices are alternately shed on each side of the body, 0 degrees out of phase

More information

Sentinel Panametrics Custody Transfer Gas Ultrasonic Flowmeter

Sentinel Panametrics Custody Transfer Gas Ultrasonic Flowmeter GE Measurement & Control Sentinel Panametrics Custody Transfer Gas Ultrasonic Flowmeter Applications The Sentinel flowmeter is a complete ultrasonic flowmeter system for the measurement of natural gas

More information

Flowmeter MDW 500. description. 230 VAC (50/60 Hz), 24 VAC/VDC with polarity reversal protection, 110VAC(60Hz) on request

Flowmeter MDW 500. description. 230 VAC (50/60 Hz), 24 VAC/VDC with polarity reversal protection, 110VAC(60Hz) on request description - industrial inductive flow meter with display unit - innovative and compact connection head design - measurement of different liquids in a variety of sectors - various process connections

More information

A1 Commercial Grade Meters

A1 Commercial Grade Meters A1 Commercial Grade Meters Commercial Grade Meters are designed as self-contained, battery powered units. These indicating meters come in Aluminum or Nylon only. A1 Meters are not field serviceable like

More information

Insertion Flow Meters. Municipal Market Customer Presentation

Insertion Flow Meters. Municipal Market Customer Presentation Insertion Flow Meters Municipal Market Customer Presentation Topics for Discussion Product Description Product Offering Product Name Principal of Operation Why the New FPI Mag? Development Team Comparison

More information

GRUNDFOS PRODUCT GUIDE DMH. Dosing pumps

GRUNDFOS PRODUCT GUIDE DMH. Dosing pumps GRUNDFOS PRODUCT GUIDE Dosing pumps Contents Features and benefits 3 Performance range 4 Pump selection options 36 Pumped liquids List of pumped liquids 39 Identification Type key 7 Functions Functional

More information

Positive Displacement Flowmeters

Positive Displacement Flowmeters Positive Displacement Flowmeters SRZ series Helical screw positive displacement flowmeters Positive Displacement Flowmeters Two highly accurate cycloid-shaped screw spindles mesh and rotate inside a cylindrical

More information

RIM20 Rotor Insertion Flowmeter

RIM20 Rotor Insertion Flowmeter Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without

More information

The readings you need, right where you need them. AX Series Vortex Meters

The readings you need, right where you need them. AX Series Vortex Meters The readings you need, right where you need them. AX Series Vortex Meters Multivariable function from a single meter Vortex multivariable meters from Azbil North America employ three sensing elements in

More information

Sentinel. Panametrics Custody Transfer Gas Ultrasonic Flowmeter. GE Sensing. Applications. Features

Sentinel. Panametrics Custody Transfer Gas Ultrasonic Flowmeter. GE Sensing. Applications. Features Applications The Sentinel flowmeter is a complete ultrasonic flowmeter system for the measurement of natural gas flow applications such as: Custody transfer Transmission and distribution Underground storage

More information

MFM220 & MFM220DC Plastic-Bodied Magmeter

MFM220 & MFM220DC Plastic-Bodied Magmeter APPLICATIONS Usage monitoring, such as: Industrial wastewater discharge monitoring Cooling tower deduct metering Heap leach mining discharge monitoring Well monitoring Turf and landscape water monitoring

More information

Why measure viscosity in-line?

Why measure viscosity in-line? BROOKFIELD _ WHY MEASURE VISCOSITY IN-LINE Why measure viscosity in-line? Why Measure Viscosity In-Line? Practical application of viscosity measurement data often leads to the need for in-process control

More information

OMP POSITIVE DISPLACEMENT FLOWMETERS

OMP POSITIVE DISPLACEMENT FLOWMETERS OMP POSITIVE DISPLACEMENT FLOWMETERS Flow Pressure Level Temperature measurement monitoring control Flow Ranges from 0.53 to 26 GPH to 4 to 92 GPM Handles Viscosities to 1,000,000 cps Pressure Ratings

More information

INDUSTRIAL DYNAMICS CO

INDUSTRIAL DYNAMICS CO TS-150 Rev. B MP Oscillating Piston Flowmeter: 12.7 mm (1/2" Type MP) 25.4 mm (1" Type MP) 50.8 mm (2" Type MP) 76.2 mm (3" Type MP) TYPE MP OSCILLATING PISTON FLOWMETER 2 " Type MP with 800 Series Register,

More information

F6700 ELECTROMAGNETIC METER

F6700 ELECTROMAGNETIC METER EETROMAGNETI FOW TRANSMITTER Special Features: F6700 Full Bore type Simple and ost effective onstruction Absolutely Maintenance free Suitable for all conductive liquids and slurries Outstanding Accuracy

More information

A1 SERIES COMMERCIAL GRADE METERS A1 SERIES COMMERCIAL GRADE METERS

A1 SERIES COMMERCIAL GRADE METERS A1 SERIES COMMERCIAL GRADE METERS COMMERCIAL GRADE METERS Look for the silver label! Look for the silver label! COMMERCIAL GRADE METERS Commercial Grade Meters are designed as self-contained, battery powered units. These indicating meters

More information

Mobrey MSM400 Ultrasonic sludge density measurement system

Mobrey MSM400 Ultrasonic sludge density measurement system Technical specification sheet IP257 October 2008 Mobrey MSM400 Ultrasonic sludge density measurement system Level Features Measuring range up to 50% solids Simple keypad operation HMI menu based programming

More information

Low Profile Insertion Vortex

Low Profile Insertion Vortex Low Profile Insertion Vortex Product Features The same insertion meter can measure Steam, Gases or Liquids. Standardize on an insertion bar that can measure line sizes 2 24 Heavy Duty & Maintenance Free

More information

Electromagnetic flowmeter EMKO E

Electromagnetic flowmeter EMKO E Electromagnetic flowmeter EMKO E - Quality design - High corrosion resistance - Reliable measurement principle Doc. no.: 70, en_cat_emkoe, 8/2015 Description Electromagnetic Flowmeter EMKO E consists of

More information

Technical Data Sheet IFS 4000 KC (ENVIROMAG) Electromagnetic flowmeters. ... for water and wastewater measurements

Technical Data Sheet IFS 4000 KC (ENVIROMAG) Electromagnetic flowmeters. ... for water and wastewater measurements Technical Data Sheet KROHNE 05/2004 GR/PRINTO IFS 4000 KC (ENVIROMAG) Electromagnetic flowmeters... for water and wastewater measurements short inlet and outlet runs unaffected by contamination, solids,

More information

AMI. American Magnetics, Inc. Excellence in Magnetics and Cryogenics

AMI. American Magnetics, Inc. Excellence in Magnetics and Cryogenics Cryogenic Liquid Level Instruments Versatile Reliable Affordable AMI American Magnetics, Inc. Excellence in Magnetics and Cryogenics A Versatile Level Measurement System... A Variety of Liquids Nitrogen

More information

Ensuring Premium Performance with Foxboro I/A Series Pulsed dc Magnetic Flowmeters

Ensuring Premium Performance with Foxboro I/A Series Pulsed dc Magnetic Flowmeters Ensuring Premium Performance with Foxboro I/A Series Pulsed dc Magnetic Flowmeters 8000A/8300/9300A/9100A/9200A SERIES S Perfect for municipal water & wastewater applications 1.6 to 900 mm (1/16 to 36

More information

Metal tube variable area flowmeter for gases, liquids and steam

Metal tube variable area flowmeter for gases, liquids and steam Metal tube variable area flowmeter for gases, liquids and steam Metallic or plastic tube with a robust construction Indication by means of magnetic coupling Scales calibrated in l/h, m 3 /h, kg/h, t/h,

More information

Plastic tube variable area flowmeter for liquids and gases

Plastic tube variable area flowmeter for liquids and gases Plastic tube variable area flowmeter for liquids and gases Low cost, excellent readability and light weight Simple installation (flanged, threaded or socket ends for solvent or fusion welding connections)

More information

SENSOR MUT2300. Electromagnetic flowmeter. The electromagnetic flowmeter designed for the toughest applications DS401-1-ENG

SENSOR MUT2300. Electromagnetic flowmeter. The electromagnetic flowmeter designed for the toughest applications DS401-1-ENG SENSOR MUT2300 Electromagnetic flowmeter The electromagnetic flowmeter designed for the toughest applications DS401-1-ENG Sensor MUT2300 The MUT2300 sensors represent the state of the art of Euromag International

More information

ELECTROMAGNETIC FLOWMETERS INSTALLATION, OPERATION AND MAINTENANCE MANUAL

ELECTROMAGNETIC FLOWMETERS INSTALLATION, OPERATION AND MAINTENANCE MANUAL ELECTROMAGNETIC FLOWMETERS INSTALLATION, OPERATION AND MAINTENANCE MANUAL 30119-03 Rev. 4.8 April, 2013 TABLE OF CONTENTS Section Page 1. INTRODUCTION...1 1.1 Description...1 1.2 Uncrating...1 1.3 Serial

More information

FIELD DEVICES - FLOW PSS 1-6F9 A. Product Specifications

FIELD DEVICES - FLOW PSS 1-6F9 A. Product Specifications FIELD DEVICES - FLOW Product Specifications Logo 9100A Series Magnetic Flowtubes with Ebonite Liners 1 to 78 in (25 to 2000 mm) Nominal Flowtube Sizes The Foxboro brand 9100A Series Magnetic Flowtube together

More information