Air Preparation Units General Line, QIX, High Efficiency Filters, Dial & Precision Regulators. Catalog 0303

Size: px
Start display at page:

Download "Air Preparation Units General Line, QIX, High Efficiency Filters, Dial & Precision Regulators. Catalog 0303"

Transcription

1 ir Preparation Units General Line, QIX, High Efficiency Filters, ial & Precision Regulators Catalog

2 Catalog Compressed ir Treatment! CUTION: Polycarbonate bowls, being transparent and tough, are ideal for use with Filters and Lubricators. They are suitable for use in normal industrial environments, but should not be located in areas where they could be subjected to direct sunlight, an impact blow, nor temperatures outside of the rated range. s with most plastics, some chemicals can cause damage. Polycarbonate bowls should not be exposed to chlorinated hydro-carbons, ketones, esters and certain alcohols. They should not be used in air systems where compressors are lubricated with fire-resistant fluids such as phosphate ester and di-ester types. Metal bowls are recommended where ambient and/or media conditions are not compatible with polycarbonate bowls. Metal bowls resist the action of most such solvents, but should not be used where strong acids or bases are present or in salt laden atmospheres. Consult the factory for specific recommendations where these conditions exist. TO CLEN POLYCRONTE OWLS USE MIL SOP N WTER ONLY! O NOT use cleansing agents such as acetone, benzene, carbon tetrachloride, gasoline, toluene, etc., which are damaging to this plastic. Metal bowl guards are recommended for all applications.! CUTION: REGULTOR PRESSURE JUSTMENT The working range of knob adjustment is designed to permit outlet pressures within their full range. Pressure adjustment beyond this range is also possible because the knob is not a limiting device. This is a common characteristic of most industrial regulators, and limiting devices may be obtained only by special design. WRNING FILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE PROUCTS N/OR SYSTEMS ESCRIE HEREIN OR RELTE ITEMS CN CUSE ETH, PERSONL INJURY N PROPERTY MGE. This document and other information from Parker Hannifin Corporation, its subsidiaries and authorized distributors provide product and/or system options for further investigation by users having technical expertise. It is important that you analyze all aspects of your application including consequences of any failure, and review the information concerning the product or system in the current product catalog. ue to the variety of operating conditions and applications for these products or systems, the user, through its own analysis and testing, is solely responsible for making the final selection of the products and systems and assuring that all performance, safety and warning requirements of the application are met. The products described herein, including without limitation, product features, specifications, designs, availability and pricing, are subject to change by Parker Hannifin Corporation and its subsidiaries at any time without notice. Offer of Sale The items described in this document are hereby offered for sale by Parker Hannifin Corporation, its subsidiaries or its authorized distributors. This offer and its acceptance are governed by the provisions stated on the separate page of this document entitled Offer of Sale. Copyright, Parker Hannifin Corporation. ll Rights Reserved.!

3 Catalog Table of Contents Compressed ir Treatment General Information - Particulate & Coalescing Filters... - General Purpose Filters Standard Filters Coalescing Filter esiccant ryers General Information - Regulators... - General Purpose Regulators... - Standard Regulators Pilot Operated Regulators ial Regulators... - Precision Regulators General Information - Lubricators General Purpose Lubricators... - Standard Series Lubricators Mist Lubricators General Purpose Filter Regulators Standard Combinations QIX Modular FRL System QIX Particulate & Coalescing Filters QIX Regulators QIX Lubricators QIX Filter / Regulators QIX Combinations...7 QIX ccessories...7 In-Line ronze Filters...76 Tank rains...77 WMPS Pressure Sensor Offer of Sale...8

4 Catalog General Information Compressed ir Treatment Particulate and Coalescing Filters Particulate and Coalescing Filters Filtration The average -hp compressor handles four million cubic inches of air per hour. This air can contain billions of contaminating particles. t high concentration and high speed, these particles can be extremely harmful. They block orifices, erode components, and clog clearances between moving parts. In addition, when ambient air is drawn into a compressor, it can, depending on weather conditions, have relative humidity up to percent. s air is compressed and cooled, some water vapor condenses out as free water, and even with a compressor aftercooler, some moisture is swept downstream into the air system. This may result in rusted pneumatic tools and components, contaminated lubricants, and frozen air lines during low temperature periods. Other types of foreign matter in air lines include: impurities generated within the air line, such as wear particles, pipe scale and rust; construction and assembly debris; and contaminants introduced into the air system during maintenance or through leakage passages. ll these contaminants, which are of a size to cause air stream problems, should be removed by the filter. Water vapor, which is a gas, is not a contaminant in pneumatic systems until it condenses. How to Select the Proper Filter Filter element rating is the prime selection criterion. This rating must match the requirements of all downstream components. Next, the flow capacity and pressure rating of the filter should be considered. Finally, port size should match system piping to avoid unnecessary pressure drops through restricting adapters. owl material and the type of drain for the application are other choices to be made. The first step in choosing a filter is to determine the filtration requirements of the most critical components used in that system. Contamination particle size is measured in micrometers. micrometer is one millionth of a meter or.9 inches. Frequently, micrometer is abbreviated as micron or symbolized by the Greek letter µ. Particle-removing filter elements are rated according to the particle size they will trap. For most industrial applications, filter elements rated at microns are adequate. When necessary, filtration as low as microns or finer can be provided. Remember, however, that finer filtration increases the pressure drop through the element. s micron size rating varies, so does the size and type of filter. Most oils entrained in a compressed air stream are in the form of tiny mist or aerosol droplets which can pass through a standard industrial filter element. If it is necessary to remove these aerosols, an oil-removal type coalescing filter can be used. The sub-micron oil particles which escape an oil-removal filter should have no detrimental effect on industrial pneumatic components. ut if these particles must be removed for applications such as spray painting, a coalescing type element should be used. The inexact nominal filter element rating indicates that most particles that size or larger will be trapped. The absolute rating indicates that all particles that size or larger will be trapped. Filter Construction Most pneumatic filters consist of two basic elements: a diecast body, into which the inlet and outlet piping is connected, and a sealed removable bowl which contains collected contaminants. The bowl is fitted with a drain mechanism to remove liquids before they rise to the baffle level. The drain system usually operates while the filter is under pressure, but the unit must be exhausted to remove the bowl for cleaning and element service. The piping need not be disturbed Generally a transparent bowl is the most convenient because it provides easy visual inspection of the sump level. However, hostile environment, higher pressure, or higher temperature may require a metal bowl for safety. The most common plastic used for bowls is polycarbonate. This material performs satisfactorily for air pressures below PSIG and temperatures between and F. Watts offers polyethylene bowl guards for added safety. s the pressure or temperature requirement increases, you may have to specify a metal bowl with sight gauge. For extreme conditions, it is recommended that the sight gauge be eliminated. (Please refer to the individual model descriptions for specifications on bowls.) Thus, the environment determines the choice of bowl. Polycarbonates offer great strength and visibility, but can be attacked by certain chemicals. Metal bowls offer the highest pressure and temperature rating, and provide superior protection when installed in an environment containing chemicals that are incompatible with polycarbonate. Filter Operation When pressurized air enters a typical filter body. The curved inlet and deflector direct the incoming air in a downward whirling pattern. Centrifugal force hurls the larger solid and liquid water particles outward where they collect on the inner surface of the filter bowl. The particles spiral down past a baffle into a quiet chamber. The baffle prevents turbulent air in the upper bowl from re-entraining liquid contaminants and carrying them downstream. Then the dry, cleaner air follows a convoluted path through the filter element, where finer solid particles are filtered out. Finally, filtered air passes up the center of the element and out the discharge port.

5 Catalog General Information Compressed ir Treatment Particulate and Coalescing Filters Particulate and Coalescing Filters Warning! The plastic material used to manufacture the plastic bowls, and the sight gau on metal bowls, may be attacked by certain chemicals. o not use this filter on systems with air supplied by a compressor lubricated with synthetic oils or oils containing phosphate esters or chlorinated hydrocarbons. These oils can carry over into the air lines and chemically attack and possibly rupture the bowl or sight glass. lso, do not expose the bowl or sight glass to materials such as carbon tetrachloride, trichlorethylene, acetone, paint thinner, cleaning fluids, or other harmful materials, for they too will cause the plastic to craze and/or rupture. For use in environments where these, or any, chemicals may be present, consult the factory for approval. Sight Gauge ody Flange Ring O-Ring eflector Retaining Rod Filter Element Pressure Plate affle ssembly owl ssembly Coalescing Filters These high-efficiency filters operate on a somewhat different principle than particulate air filters. The key difference is in the element, where a fiber network is narrowly spaced to trap smaller contaminants. The special fibers hold any liquid particle which contacts them. Pre-filtered ( particulate filter must be used prior to a coalescing filter) air enters the cylindrical element at the center. s it flows through the element, particles are captured by three different mechanisms: direct interception as particles impinge on the fibers; inertial impaction as particles are thrown against fibers by the turbulent air stream; and diffusion as smaller particles vibrate with rownian movement to collide with fibers and other particles. s a result, coalescing elements can capture particles smaller than the nominal size of the flow passages through the element. Collected liquid migrates to the crossing points of the fibers where larger drops form or coalesce. Pressure differential through the element then forces these drops to the downstream surface of the element where they gravitate downward to the sump. The filtered air then exits through the outlet port. It is very important that the air be pre-filtered, as larger contaminants tend to block the passages between fibers, reducing the efficiency of the coalescing element. Sight Gauge Particulate Filters rain Pop-Up Indicator Plug ody Flange Ring O-Ring Retaining Rod Filter Element affle ssembly owl ssembly utomatic rain Coalescing Filters

6 Catalog F6 Series General Purpose Filters / & /8 Inch Ports F6 General Purpose Filters Manual rain utomatic rain Features Excellent Water Removal Efficiency For Heavy uty pplications with Minimum Pressure rop Requirement Unique eflector Plate that Creates Swirling of the ir Stream Ensuring Maximum Water and irt Separation F Large Filter Element Surface Guarantees Low Pressure rop and Increased Element Life Micron Filter Element Standard, Micron vailable E Metal owl with Sight Gauge Standard Twist rain as Standard, Optional uto rain Large owl Capacity C High Flow: /" - SCFM /8" - 68 SCFM SCFM = Standard cubic feet per minute at PSIG inlet, and PSIG pressure drop with micron element. NPT SPP Port Size Manual Internal Manual Internal Twist rain uto rain Twist rain uto rain Polycarbonate owl / Plastic Guard /" F6-J F6-JR F6GJ F6GJR /8" F6-J F6-JR F6GJ F6GJR Metal owl / Sight Gauge /" F6-WJ F6-WJR F6GWJ F6GWJR /8" F6-WJ F6-WJR F6GWJ F6GWJR Standard part numbers shown bold. For other models refer to ordering information below. F6 Filter imensions C E F F6-, F (7) () () (6) () (7) F6-W, F6-W (7) (6) () (6) () (7) inches (mm) Ordering Information F 6 W J /** Port Threads Port Size owl Elements rains and Options Engineering Change esignator NPT G SPP / Inch /8 Inch Polycarbonate with Plastic owl Guard W Metal with Sight Gauge G Micron J Micron lank Manual Twist rain R Internal uto rain S utomatic Pulse rain (For Polycarbonate owls [] Only) Will be entered at factory. X No Internal Parts NOTE: OL OPTIONS RE STNR.

7 Catalog (Revised //6) Technical Specifications F6 F6 Series General Purpose Filters Technical Information Pressure rop - bar... Pressure rop - PSIG Primary Pressure - bar Primary Pressure - PSIG 7 F6-J /-inch Port 6 Pressure rop - bar Pressure rop - PSIG 8 6 Primary Pressure - bar Primary Pressure - PSIG 7 F6-J /8-inch Port 6 8 Flow - dm n /s Flow - dm n /s F6 Filter Kits & ccessories owl Kits Metal with Sight Gauge (W)... K6WY Polycarbonate ()... K6Y rain Kits Internal uto (ll)... S6M Manual Twist (ll)... S6Y7- utomatic Pulse ()... RK6SY Semi-utomatic Overnight rain... S67 (rains automatically under zero pressure) Filter Element Kits Micron (,W)... EK6VY Micron (,W)... EK6Y Mounting racket Kit... (ll) SF6-7 Repair Kits eflector, Secondary affle, Primary affle, and Retaining Rod (,W)... RK6Y Internal uto rain (ll)... RK6M Metal owl with Sight Gauge (W)... RK6WY ( ) = owl Type Specifications owl Capacity... Ounces Port Threads... /, /8 Inch Pressure & Temperature Ratings Polycarbonate owl... to PSIG ( to. bar) F to F (. C to C) Metal owl... to PSIG ( to 7. bar) F to F (. C to 6.6 C) (With Internal uto rain to 7 PSIG (. to.9 bar) Weight Polycarbonate owl.... lb. (.68 kg) / Unit 8 lb. (8.6 kg) / -Unit Master Pack Metal owl....8 lb. (.8 kg) / Unit lb. (9.98 kg) / -Unit Master Pack Materials of Construction ody... Zinc owls ()... Polycarbonate Polycarbonate (W)... Metal (Zinc) with Sight Gauge owl Guards... Plastic rain Manual Twist & Overnight... rass Internal uto & Piston... cetal Filter Elements Micron (Standard)... Polypropylene Micron (Optional)... Polypropylene Seals... una N Sight Gauge... Nylon

8 Catalog F6 Series General Purpose Filters / Inch Ports F6 General Purpose Filters Manual rain utomatic rain Features Excellent Water Removal Efficiency For Heavy uty pplications with Minimum Pressure rop Requirement Unique eflector Plate that Creates Swirling of the ir Stream Ensuring Maximum Water and irt Separation IN OUT F Large Filter Element Surface Guarantees Low Pressure rop and Increased Element Life Micron Filter Element Standard, Micron vailable E Metal owl with Sight Gauge Standard Twist rain as Standard, Optional uto rain Large owl Capacity C Optional High Capacity owl(s) vailable High Flow: /" - 9 SCFM SCFM = Standard cubic feet per minute at PSIG inlet, and PSIG pressure drop with micron element. NPT SPP Port Size Manual Internal Manual Internal Twist rain uto rain Twist rain uto rain Polycarbonate owl / Plastic Guard /" F6-J F6-JR F6GJ F6GJR Metal owl / Sight Gauge /" F6-WJ F6-WJR F6GWJ F6GWJR luminum owl 6 oz. without Sight Gauge /" F6-EJ F6-EJR F6GEJ F6GEJR Standard part numbers shown bold. For other models refer to ordering information below. F6 Filter imensions C E F F (96) () (67) (8) () (8) F6-E (96) (6) () (8) () (8) F6-W (96) (6) (7) (8) () (8) inches (mm) Ordering Information F 6 W J /** Port Threads Port Size owl Elements rains and Options Engineering Change esignator NPT G SPP / Inch 8 oz. Polycarbonate with Plastic owl Guard E 6 oz. Large Capacity without Sight Gauge G Micron J Micron lank Manual Twist rain Q External Heavy uty uto rain R Internal uto rain Will be entered at factory. W 8 oz. Metal with Sight Gauge NOTE: OL OPTIONS RE STNR. 6

9 Catalog (Revised //6) Technical Specifications F6 F6 Series General Purpose Filters Technical Information Pressure rop - bar... Pressure rop - PSIG Primary Pressure - bar Primary Pressure - PSIG 7 F6-J /-inch Port 6 8 Flow - dm /s n Q Option External Heavy uty uto rain S6 / S6 For heavy duty applications where the filter is being used to remove large volumes of liquid and/or particulate matter from the airstream, the external automatic drain ( Q option) should be used. F6 Filter Kits & ccessories owl Kits luminum (E)... K6 Metal with Sight Gauge (W)... K6W Polycarbonate with Plastic owl Guard ()... K6 rain Kits External uto (,W)... S6 External uto (E)... S6 Internal uto (ll)... S6M Manual Twist (ll)... S6Y7- Semi-utomatic Overnight rain... S67 (rains automatically under zero pressure) Filter Element Kits Micron (ll)... EK6V Micron (ll)... EK6 Mounting racket Kit... (ll) SF6-7 Repair Kits eflector, affle ssembly, and Retaining Rod (ll)... RK6 External uto rain (ll)... RK6 Internal uto rain (ll)... RK6M Metal owl with Sight Gauge (W)... RK6W Specifications owl Capacity (, W)... 8 Ounces (E)... 6 Ounces Port Threads... / Inch ( ) = owl Type rain (/" NPTF) Float (Inside owl) Connection Through owl (/8" NPSM) Manual Push utton rain (Outside owl) Pressure & Temperature Ratings Polycarbonate owl ()... to PSIG ( to. bar) F to F (. C to C) Metal owl (W)... to PSIG ( to 7. bar) F to F (. C to 6.6 C) luminum owl (E)... to PSIG ( to. bar) F to F (. C to 6.6 C) With Internal uto rain (R)... to 7 PSIG (. to.9 bar) F to F (. C to C) With External uto rain (Q)... to PSIG ( to 7. bar) F to F (. C to 6.6 C) (Except with Polycarbonate owl - See bowl limits) Weight Polycarbonate owl ().... lb. (.9 kg) / Unit 9 lb. (8.6 kg) / 8-Unit Master Pack Metal owl (W)....8 lb. (.7 kg) / Unit lb. (9.98 kg) / 8-Unit Master Pack luminum owl (E)....6 lb. (.6 kg) / Unit 9 lb. (. kg) / 8-Unit Master Pack Materials of Construction ody... Zinc owls ()... Polycarbonate Polycarbonate (W)... Metal (Zinc) (E)...luminum owl Guards... Plastic rain Manual Twist & Overnight... rass Internal uto... cetal Filter Elements Micron (Standard)... Polypropylene Micron (Optional)... Polypropylene Seals... Nitrile Sight Gauge... Nylon 7

10 Catalog F6 Series Standard Filters / & Inch Ports F6 Standard Filters Manual rain utomatic rain Features Excellent Water Removal Efficiency For Heavy uty pplications with Minimum Pressure rop Requirement Unique eflector Plate that Creates Swirling of the ir Stream Ensuring Maximum Water and irt Separation Large Filter Element Surface Guarantees Low Pressure rop and Increased Element Life Micron Filter Element Standard, Micron vailable Metal owl with Sight Gauge Standard Twist rain as Standard, Optional uto rain Large owl Capacity Optional High Capacity owl(s) vailable High Flow: /" - SCFM, " - SCFM IN OUT F E C SCFM = Standard cubic feet per minute at PSIG inlet, and PSIG pressure drop with micron element. NPT SPP Port Size Manual Internal Manual Internal Twist rain uto rain Twist rain uto rain Metal owl / Sight Gauge /" F6-6WJ F6-6WJR F6G6WJ F6G6WJR " F6-8WJ F6-8WJR F6G8WJ F6G8WJR luminum owl oz. without Sight Gauge /" F6-6EJ F6-6EJR F6G6EJ F6G6EJR " F6-8EJ F6-8EJR F6G8EJ F6G8EJR Standard part numbers shown bold. For other models refer to ordering information below. F6 Filter imensions C E F F6-6W, F6-8W () () () () () (6) F6-6E, F6-8E () (8) () () () (6) inches (mm) Ordering Information F 6 6 W J /** Port Threads Port Size owl Elements rains and Options Engineering Change esignator NPT G SPP 6 / Inch 8 Inch E oz. Large Capacity without Sight Gauge W 6 oz. Metal with Sight Gauge G Micron J Micron lank Manual Twist rain Q External Heavy uty uto rain R Internal uto rain Will be entered at factory. NOTE: OL OPTIONS RE STNR. 8

11 Catalog (Revised //6) Technical Specifications F6 F6 Series Standard Filters Technical Information Pressure rop - bar... Pressure rop - PSIG Primary Pressure - bar Primary Pressure - PSIG 7 F6-6WJ /-inch Port Pressure rop - bar... Pressure rop - PSIG Primary Pressure - bar Primary Pressure - PSIG 7 F6-8WJ -inch Port 6 8 Flow - dm /s n Flow - dm /s n Q Option External Heavy uty uto rain S6 / S6 For heavy duty applications where the filter is being used to remove large volumes of liquid and/or particulate matter from the airstream, the external automatic drain ( Q option) should be used. rain (/" NPTF) Float (Inside owl) Connection Through owl (/8" NPSM) Manual Push utton rain (Outside owl) F6 Filter Kits & ccessories owl Kits Metal with Sight Gauge (W)... K6W luminum (E)... K6 rain Kits External uto (W)... S6 External uto (E)... S6 Internal uto (ll)... S6M Manual (ll)... S6Y7- Semi-utomatic Overnight rain... S67 (rains automatically under zero pressure) Filter Element Kits Micron (ll)... EK6 Micron (ll)... EK6V Mounting racket Kit (Pair or Kits of Pipe Mounted rackets needed) (/" Unit)... SW7 (" Unit)... SCW7 Repair Kits eflector, affle ssembly, and Retaining Rod (E,W)... RK6 External uto rain (ll)... RK6 Internal uto rain (ll)...rk6m Metal owl with Sight Gauge (W)... RK6W Specifications owl Capacity Metal owl (W)... 6 Ounces Metal owl (E)... Ounces Port Threads... /, Inch ( ) = owl Type Pressure & Temperature Ratings Metal owl (W)... to PSIG ( to 7. bar) F to F (. C to 6.6 C) luminum owl (E)... to PSIG ( to. bar) F to F (. C to 6.6 C) With Internal uto rain (R)... to 7 PSIG (. to.9 bar) F to F (. C to C) With External uto rain (Q)... to PSIG ( to 7. bar) F to F (. C to 6.6 C) Weight Metal owl (W) lb. (.86 kg) / Unit Metal owl (E)... lb. (. kg) / -Unit Master Pack luminum owl... 7 lb. (.8 kg) / Unit 8 lb. (.7 kg) / -Unit Master Pack Materials of Construction ody... Zinc owls Metal owl (W)... Zinc with Sight Gauge Metal owl (E)... luminum without Sight Gauge rain Manual Twist & Overnight... rass Housing R... cetal Housing Q... ronze Filter Elements Micron (Standard)... Polypropylene Micron (Optional)... Polypropylene Seals... Nitrile Sight Gauge... Nylon 9

12 Catalog F6 Series Standard Filters -/ & -/ Inch Ports F6 Standard Filters Manual rain utomatic rain Features Excellent Water Removal Efficiency For Heavy uty pplications with Minimum Pressure rop Requirement Unique eflector Plate that Creates Swirling of the ir Stream Ensuring Maximum Water and irt Separation IN OUT F Large Filter Element Surface Guarantees Low Pressure rop and Increased Element Life Micron Filter Element Standard, Micron vailable E Metal owl with Sight Gauge Standard Twist rain as Standard, Optional uto rain Large owl Capacity C Optional High Capacity owl(s) vailable High Flow: -/" - 9 SCFM -/" - SCFM SCFM = Standard cubic feet per minute at PSIG inlet, and PSIG pressure drop with micron element. NPT SPP Port Size Manual Internal Manual Internal Twist rain uto rain Twist rain uto rain Metal owl / Sight Gauge -/" F6-WJ F6-WJR F6GWJ F6GWJR -/" F6-WJ F6-WJR F6GWJ F6GWJR luminum owl oz. without Sight Gauge -/" F6-EJ F6-EJR F6GEJ F6GEJR -/" F6-EJ F6-EJR F6GEJ F6GEJR Standard part numbers shown bold. For other models refer to ordering information below. F6 Filter imensions C E F F6-W, F6-W () (8) () () (.) (6.) F6-E, F6-E () (9) () () (.) (6.) inches (mm) Ordering Information F 6 W J /** Port Threads Port Size owl Elements rains and Options Engineering Change esignator NPT G SPP -/ Inch -/ Inch E oz. Large Capacity without Sight Gauge W 6 oz. Metal with Sight Gauge G Micron J Micron lank Manual Twist rain Q External Heavy uty uto rain R Internal uto rain Will be entered at factory. NOTE: OL OPTIONS RE STNR.

13 Catalog (Revised //6) Technical Specifications F6 F6 Series Standard Filters Technical Information Primary Pressure - bar Primary Pressure - PSIG 7 Primary Pressure - bar Primary Pressure - PSIG 7. Pressure rop - bar.. Pressure rop - PSIG F6-WJ -/-inch Port Flow - dm n /s Pressure rop - bar... Pressure rop - PSIG F6- WJ -/-inch Port Flow - dm n /s Q Option External Heavy uty uto rain S6 / S6 For heavy duty applications where the filter is being used to remove large volumes of liquid and/or particulate matter from the airstream, the external automatic drain ( Q option) should be used. rain (/" NPTF) Float (Inside owl) Connection Through owl (/8" NPSM) Manual Push utton rain (Outside owl) F6 Filter Kits & ccessories owl Kits Metal with Sight Gauge (W)... K6W luminum (E)... K6 rain Kits External uto (W)... S6 External uto (E)... S6 Internal uto (ll)... S6M Manual (ll)... S6Y7- Semi-utomatic Overnight rain... S67 (rains automatically under zero pressure) Filter Element Kits Micron (ll)... EK6 Micron (ll)... EK6V Repair Kits eflector, affle ssembly, and Retaining Rod (ll)... RK6C External uto rain (ll)... RK6 Internal uto rain (ll)... RK6M Metal owl with Sight Gauge (W)... RK6W Specifications owl Capacity Metal (W)... 6 Ounces luminum (E)... Ounces Port Threads... -/, -/ Inch ( ) = owl Type Pressure & Temperature Ratings Metal owl (W)... to PSIG ( to 7. bar) F to F (. C to 6.6 C) luminum owl (E)... to PSIG ( to. bar) F to F (. C to 6.6 C) With Internal uto rain (R)... to 7 PSIG (. to.9 bar) F to F (. C to C) With External uto rain (Q)... to PSIG ( to 7. bar) F to F (. C to 6.6 C) Weight Metal owl (W)... 7 lb. (.8 kg) / Unit 8 lb. (.7 kg) / -Unit Master Pack luminum owl (E) lb. (.9 kg) / Unit lb. (.6 kg) / -Unit Master Pack Materials of Construction ody... Zinc owls (W)... Metal (Zinc) with Sight Gauge (E)... luminum without Sight Gauge rain Manual Twist & Overnight... rass Housing R... cetal Housing Q... ronze Filter Elements Micron (Standard)... Polypropylene Micron (Optional)... Polypropylene Seals... Nitrile Sight Gauge... Nylon

14 Catalog F6 Series Standard Filters & -/ Inch Ports F6 Standard Filters Manual rain utomatic rain Features Excellent Water Removal Efficiency For Heavy uty pplications with Minimum Pressure rop Requirement Unique eflector Plate that Creates Swirling of the ir Stream Ensuring Maximum Water and irt Separation Large Filter Element Surface Guarantees Low Pressure rop and Increased Element Life Micron Filter Element Standard, Micron vailable Metal owl with Sight Gauge Standard Twist rain as Standard, Optional uto rain F E C Large owl Capacity Optional High Capacity owl(s) vailable High Flow: " & -/" - SCFM SCFM = Standard cubic feet per minute at PSIG inlet, and PSIG pressure drop with micron element. NPT SPP Port Size Manual Internal Manual Internal Twist rain uto rain Twist rain uto rain Metal owl / Sight Gauge " F6-6WJ F6-6WJR F6G6WJ F6G6WJR -/" F6-WJ F6-WJR F6GWJ F6GWJR luminum owl oz. without Sight Gauge " F6-6EJ F6-6EJR F6G6EJ F6G6EJR -/" F6-EJ F6-EJR F6GEJ F6GEJR Standard part numbers shown bold. For other models refer to ordering information below. F6 Filter imensions C E F F6-6W, F6-W (6) (8) () (6) (8.7) (6.) F6-6E, F6-E (6) (6) () (6) (8.7) (6.9) inches (mm) Ordering Information F 6 6 W J /** Port Threads Port Size owl Elements rains and Options Engineering Change esignator NPT G SPP 6 Inch -/ Inch E oz. Large Capacity without Sight Gauge W 6 oz. Metal with Sight Gauge J Micron lank Manual Twist rain Q External Heavy uty uto rain R Internal uto rain Will be entered at factory. NOTE: OL OPTIONS RE STNR.

15 Catalog (Revised //6) Technical Specifications F6 F6 Series Standard Filters Technical Information Primary Pressure - bar Primary Pressure - PSIG 7. Pressure rop - bar.. Pressure rop - PSIG F6-6/ -inch Port Flow - dm n /s Q Option External Heavy uty uto rain S6 / S6 For heavy duty applications where the filter is being used to remove large volumes of liquid and/or particulate matter from the airstream, the external automatic drain ( Q option) should be used. rain (/" NPTF) Float (Inside owl) Connection Through owl (/8" NPSM) Manual Push utton rain (Outside owl) F6 Filter Kits & ccessories owl Kits Metal with Sight Gauge (W)... K6W luminum (E)... K6 rain Kits External uto (W)... S6 External uto (E)... S6 Internal uto (ll)... S6M Manual (ll)... S6Y7- Semi-utomatic Overnight rain... S67 (rains automatically under zero pressure) Filter Element Kits... Micron (ll) EK6G Repair Kits eflector, affle ssembly, and Retaining Rod (ll)... RK6G External uto rain (ll)... RK6 Internal uto rain (ll)... RK6M Metal owl with Sight Gauge (W)... RK6W Specifications owl Capacity Metal (W)... 6 Ounces luminum (E)... Ounces Port Threads..., -/ Inch ( ) = owl Type Pressure & Temperature Ratings Metal owl (W)... to PSIG ( to 7. bar) F to F (. C to 6.6 C) luminum owl (E)... to PSIG ( to. bar) F to F (. C to 6.6 C) With Internal uto rain (R)... to 7 PSIG (. to.9 bar) F to F (. C to C) With External uto rain (Q)... to PSIG ( to 7. bar) F to F (. C to 6.6 C) Weight Metal owl (W) lb. (. kg) / Unit 9 lb. (7.69 kg) / -Unit Master Pack luminum owl (E).... lb. (.67 kg) / Unit lb. (.99 kg) / -Unit Master Pack Materials of Construction ody...luminum owls (W)... Metal (Zinc) with Sight Gauge (E)... luminum without Sight Gauge rain Manual Twist & Overnight... rass Housing R... cetal Housing Q... ronze Filter Elements Micron (Standard)... Polypropylene Seals... una N Sight Gauge... Nylon

16 Catalog F7 Series (Revised //6) Coalescing Filters /, /8, /, / & Inch Ports F7 Coalescing Filters Features Removes Liquid erosols and Sub-micron Particles Protects Pneumatic Systems from Contamination that Standard Particulate Filters Will Not Catch Two ifferent Grade Elements vailable ifferential Pressure Pop-up Indicator Standard ifferential Pressure Gauge Optional High Flow esign Note: ll coalescing filters should be protected by a particulate filter (i.e., F6, or other) installed upstream. F E C Grade 6 Grade Port Flow Part Flow Part Size (SCFM)* Number (SCFM)* Number /" F7-WP 6 F7-W7P /8" F7-WP 6 F7-W7P /" F7-WP 6 F7-W7P /" F7-EP 88 F7-E7P /8" F7-EP 88 F7-E7P /" F7-EP 88 F7-E7P /" 9 F7-6EP 8 F7-6E7P /" 7 F7-6LP 8 F7-6L7P " 9 F7-8EP 8 F7-8E7P " 7 F7-8LP 8 F7-8L7P * ry media flow. For wet media info see table to right F7 Coalescing Filter imensions owl Port Size Capacity C E /, /8, / Inch (W) 8 oz (96) () (8) (8) () /, /8, / Inch (E) 6 oz (96) (8) (6) (8) () /, Inch (E) oz (6) (99) () () () /, Inch (L) oz (6) () (7) () () G ifferential Pressure Gauge add.(.8) to C & E. Q External uto rain add.7 (.) to & C. inches (mm) Ordering Information F 7 W P T /** Port Threads Port Size owl Elements NPT / Inch E Metal without Grade 6 G SPP /8 Inch Sight Gauge 7 Grade / Inch W Metal with 6 / Inch Sight Gauge 8 Inch L* High Capacity Metal owl without Sight Gauge * / & " Only NOTE: OL OPTIONS RE STNR. / & / Only Element Service Indicator lank None P Pop-up Style G ifferential Pressure Gauge owl rains lank Manual Twist rain T Internal utomatic rain Q External uto rain Engineering Change esignator Will be entered at factory.

17 Catalog (Revised //) Technical Specifications F7 F7 Series Coalescing Filters Element Selection Element Grade pplications 6 General air coalescing applications when total removal of liquid aerosols and suspended fines is required in all pressure ranges. Protection of air dryers, air gauging, air logic, modulating systems, critical air conveying, most breathing air systems, etc. Precoalescer or prefilter for Grade 6 to remove gross amounts of water and oil, or tenacious aerosols which are difficult to remove. Upgrading existing particulate equipment to coalescing without increase in pressure drop. Element Specifications Pressure rop (PSI) Rated Flow r Coalescing a Efficiency Maximum Media d. to.6 Micron Oil Carryover Media Wet with Particulate e Particles PPM w/w ry - wt. Oil Micron Rating % % Tested per CS 869 at ppm inlet. dd dry + wet for total pressure drop. Primary Pressure - PSIG F7-W* F7-W* F7-W* F7-E* F7-E* F7-E* F7-6E* F7-8E* F7-6L* F7-8L* Flow - dm n /s F7 Filter Kits & ccessories Mounting racket Port Size /, /8, / (Mounts to Filter Head)... SF6-7 / (Pair of Pipe Mounted rackets)... SW7 (Pair of Pipe Mounted rackets)... SCW7 owl Kit Port Size /, /8, / Inch (W)... K6W /, /8, / Inch (E)... K6 /, Inch (E)... K6 /, Inch (L)... K6C ifferential Pressure Pop Up Indicator Repair Kit... RK7P (only works with originally equipped units) ifferential Pressure Gauge... P76-P (only works on units without pop-up indicator) rain Kits Internal utomatic rain - High Pressure (T)... S7M Manual Twist rain... S6Y7- Filter Element Kits Port Size Grade 6 /, /8, / Inch (W)... F7-C-77 /, /8, / Inch (E)... F7-C-77 /, Inch (E)... F7-C-77 /, Inch (L)... F7-C-77 Port Size Grade /, /8, / Inch (W)... F7-C7-77 /, /8, / Inch (E)... F7-C7-77 /, Inch (E)... F7-C7-77 /, Inch (L)... F7-C7-77 Specifications Operation Maximum Recommended Pressure rop... PSIG (element should be replaced) Normal Operating Pressure rop (ry)... PSIG Normal Operating Pressure rop (Wet)... PSIG ( ) = owl Type Minimum Recommended Flow... % of Rated Flow Maximum Pressure (With Manual rains) /, /8, / Inch (W)... to PSIG (-7 bar) /, /8, / Inch (E)... to PSIG (- bar) / Inch (E)... to PSIG (- bar) Inch (L)... to PSIG (- bar) Maximum Pressure (With utomatic rains) R rain... 7 PSIG ( bar) T rain... PSIG (7 bar) Q rain... PSIG (7 bar) Maximum Temperature... F to F ( C to 6 C) Maximum temperature with T, R, or Q rains... F ( C) Weight /, /8, / Inch (W 8 oz.).... lb. /, /8, / Inch (E 6 oz.).... lb. / Inch (E oz.)... lb. Inch (L oz.)... 8 lb. Materials of Construction ody & Flange Ring... Zinc owl Metal owl (W)... Zinc with Nylon Sight Gauge Metal owl (E) (L)... luminum rains utomatic Float rain Housing R, T... cetal Housing Q... ronze Manual Twist rain... rass Seals & Float... una N Springs... Stainless Steel Elements (Media)... orosilicate Fibers & Felt Element End Caps... Urethane Seals... una N

18 Catalog (Revised /6/6) Main Line F, F, F Series F, F, F Series -/,, -/ & Inch Ports F, F, F Coalescing Filters Main Line Features Removes Liquid erosols and Sub-micron Particles Liquids Gravitate to the ottom of the Element and Will Not Re-enter the irstream Oil Free ir For Critical pplications, such as ir Gauging and Pneumatic Instrumentation and Controls ifferential Pressure Indicator Standard High Flow: Port Size Model Sump Capacity SCFM -/" F.8 Oz. " F8 7.9 Oz. " F8L.9 Oz. 6 -/" F9 9.7 Oz. 8 " FN 9.7 Oz. SCFM = Standard cubic feet per minute at 9 PSIG inlet and PSIG pressure drop. C E istance Required To Remove ll owls F Regardless Of rain Option Port Size Metal owl without Sight Gauge Twist rain -/" F7ECP " F8ECP " F8LECP -/" F9LECP " FNLECP Standard part numbers shown bold, with Grade 6 Elements (for Grade Elements, replace E with H in the 6th position). For other models refer to ordering information below. F7 F77 F8 F8L F87 F8M F9L F9M FNL FNM Inches (mm) Main Line Coalescing Filter imensions C E F () () (6) (6) () () () () (6) () (6) () () () (6) (99) (66) (89) () () (6) (76) (79) (6) () () (6) (9) (69) (89) () () (6) (7) (76) (6) () (9) (8) (88) (96) (7) () (9) (8) (87) (99) (7) () (9) (8) (88) (96) (7) () (9) (8) (87) (99) (7) Ordering Information F 7 E C P Engineering Port Size owl Options Elements Level Options F 7. -/ Inch F 8. Inch F 9. -/ Inch N. Inch Twist rain. Short owl (F, F) L. Long owl (F, F) Metal owl with utomatic Float rain 7. Short owl (F, F) M. Long owl (F, F) NOTE: OL OPTIONS RE STNR. E. Grade 6 H. Grade C. Current P. Pressure ifferential Indicator 6

19 Catalog (Revised /6/6) Technical Specifications F, F, F F, F, F Series Coalescing Filters Technical Information F7E* F8E* F8LE* F9LE* FNLE* Primary Pressure - bar 6 Primary Pressure - PSIG Rated 9 Flow - dm /s n F, F, F Coalescing Filter Kits & ccessories owl Kit Metal / Twist rain F... 68P F P F8L... 6P F... 6P PI Replacement Kit F, F8, F8L, F... P ifferential Pressure Indicating Gauge F, F8, F8L, F... P rain Kits utomatic Float rain F, F8, F8L, F... PS6P Filter Element Kits Grade 6 (Standard) F xP F xP F8L xP F xP Grade (Optional) F xP F xP F8L xP F xP 7 Specifications Sump Port Model Capacity Threads Weight F....8 Oz.... -/"....9 lb. (. kg) F Oz....".... lb. (6. kg) F8L....9 Oz...."....9 lb. (7. kg) F Oz.... -/".... lb. (.9 kg) FN Oz....".... lb. (. kg) Operation Normal Operating Pressure rop... PSIG Maximum Recommended Pressure rop... PSIG (Element should be replaced) Minimum Recommended Flow... % Pressure & Temperature Ratings... to PSIG ( to 7. bar) F to 7 F ( C to 8 C) Materials of Construction ody... luminum owl... luminum without Sight Gauge rains Twist rain... rass Petcock utomatic Float rain Housing, Float... Plastic Seals... una N Springs, Push Rod... Stainless Steel Filter Element orosilicate & felt glass fibers 99.97% OP efficiency Largest erosol Particle Passed (Grade 6)....7 Microns Largest Solid Particle Passed (Grade 6).... Microns Seals... Nitrile

20 Catalog (Revised //7) esiccant ryers Series Series /", /8", /", /", " esiccant ryers Features These esiccant ryers are a Convenient and Cost Effective Means of Ensuring Your Sensitive Pneumatic pplications are Never Exposed to amaging Moisture Compact Size for Point-of-Use pplications rying Efficiency own to - F Pressure ew Point Easily and Quickly Serviced Sightglass in owl to Monitor esiccant uilt-in Particulate after Filter Prevents ownstream ust No Electricity Needed Low Pressure rop No Purge ir Lost as with Other ryer Types C E pplications Paint Spraying Instrument ir Laboratory Instruments Control ir Systems ir lanketing Performance The rated flow capacities are nominal ratings provided for reference. These capacities are recommended for minimal pressure drop and average desiccant life. supply of low flow / low humidity air will provide longer desiccant life: whereas, high flow / high humidity air will require more frequent desiccant changes. Installed in an application with intermittent flow, these desiccant dryers will typically dry air for weeks before the silica gel desiccant requires replacement or regeneration. esiccant ryer imensions C * E () () () () () () (7) () () (9) () (78) () () (768) * imension does not include reducer bushings for /", /8", /" versions inches (mm) Ordering Information Port Size SCFM SCFM 6 SCFM esiccant Capacity¹. lb¹ lb.¹ lb.¹ /" ² - N/ N/ /8" ² - N/ N/ /" ² /" " N/ Notes:. esiccant must be ordered separately.these units supplied with reducer bushings 8

21 Catalog Technical Specifications Series s the wet compressed air enters through the inlet, the air travels down through the bed of desiccant which adsorb the water vapor and aerosols. The silica gel desiccant beads will reduce the humidity down to a - F pressure dew point. fter the moisture has been removed, the dry air passes through a sintered bronze filter element (eliminating dust downstream), up the tube and out the outlet port. s the desiccant becomes saturated with moisture, the dew point will begin to rise. This is evident when the blue silica gel desiccant beads in the sight gauge change to pink, indicating the need for desiccant replacement. Simply remove the flange and bowl and replace with new desiccant or regenerate saturated desiccant by heating to 7 F. Wet ir In ry ir Out Series esiccant ryers Installation Tips lways place a moisture separator/particulate filter (i.e., F6) to remove bulk moisture and a coalescing filter (i.e., F7) to remove oil upstream of desiccant dryer. esiccant coated with oil will not adsorb oil. utomatic drains should be used in prefilters spring ball check valve should be installed at the dryer inlet to maximize the life of the desiccant. ir Compressor ftercooler & rain Trap Stage Stage Stage F6 Particulate Filter F7 Coalescing Filter Check Valve esiccant ryer uick Remove Flange Silica Gel siccant t Glass ir Preparation Stages Function Served in Stage Type of Filter Example Compressed ir System Particulate / F6 Removes bulk moisture Moisture & particulate matter ¹ Removal Filters Coalescing F7, F, F Removes fine particulate Filters matter, moisture droplets and aerosols, but NOT vapor² esiccant ryer,, 6 Removes moisture vapor³ Notes:. Removes approx 7% of moisture. Removes approx 99.97% efficient in removing oil & water aerosols >. micron. Provides pressure dew point of - F with unsaturated desiccant esiccant ryers Kits & ccessories esiccant - Silica Gel % Indicating lb. Can... SGM- Four - lb. Cans... SGM- Flow Tube Repair Kit (Tube, Filter Element(s), daptor)... RK RK RK6--8 Mounting rackets (Recommended for & only) / Inch Pipe Size (Pair of Pipe Mounted rackets)... SYW7 Inch Pipe Size (Pair of Pipe Mounted rackets)... SCW7 Spring Check Valve for Inlet ( PSIG max.) (Maximizes Life of esiccant) / Inch NPT... 9 /8 Inch NPT... 9 / Inch NPT... 9 / Inch NPT... 9 Specifications esiccant Capacity (esiccant must be ordered separately).... lb.... lb lb. Filter Element Rating,... 9 micron 6... micron Pressure & Temperature Ratings Optimum working temperature... elow F Pressure Range... to PSIG Temperature Range... F to 8 F Weight (Housing Only) (add. lb for weight full)... 8 lb. (add lb for weight full)... lb. 6 (add lb for weight full)... lb. Materials of Construction owl,... luminum 6... Steel Flow Tube... CPVC Filter Elements... Sintered ronze Head & Flange Ring... Zinc Other Hardware... rass Seals... una-n Sight Glass... Glass & Steel 9

22 Catalog General Information Compressed ir Treatment Regulators Regulators Regulation n air regulator is a specialized control valve. It reduces upstream supply pressure level to a specified constant downstream pressure. Pneumatic equipment that is operated at higher-thanrecommended pressure wastes the energy to generate that pressure. It creates a potential safety hazard, and probably will wear out prematurely. Operating below specified pressure can cause the machine to fail to meet design performance specifications. Therefore, precise air pressure control is essential to efficient operation of air-powered equipment. How to Select the Proper Regulator While regulator bodies are generally constructed of die-cast metal, other external parts may be either metal or plastic. Remember that all-metal construction is best for tough applications, where abuse is likely to occur, but plastic construction is generally lower in cost. For normal industrial applications, either construction is suitable. Inlet pressure rating and downstream controlled range, as well as flow capacity, must be determined before selecting a regulator. Port size should match piping size. Required response time, relieving capability, and type of adjustment are other considerations. Highly sensitive, lightweight diaphragm sensors vs. the slower, but often more durable, piston sensors. Self-relieving vs. non-relieving regulators. T-Handles or knobs as the adjustment mechanism, or air pilot operated regulator which offer remote adjustment. Other choices to be made include gauge, panel mount and other special options. Regulator Construction Regulators are generally constructed using a die-cast metal body. Other external parts, such as the spring cage and bottom plug, may be either metal or plastic. ll-metal construction offers more durability in tough applications where abuse is likely to occur, while the plastic construction offers lower cost. For normal industrial applications (temperature range of to F and supply pressure to PSIG), either construction will serve well. Lightweight diaphragm sensors offer quick response and high sensitivity to air pressure changes. Piston sensors are somewhat slower but may be more durable. Where downstream pressure requirements change rapidly enough to cause regular chatter, slower response may be an advantage. If the self-relieving feature is not needed for an application, simpler non-relieving regulators are available. For regulators with an adjustment spring, a -T-Handle or knob provides the external link to the spring on various models. Pilot-operated regulators substitute air pressure in the chamber above the sensor to provide the reference force. Remote adjustment through a separate pilot regulator thus becomes possible, or the pilot signal can be fed back from a downstream location for precise control. The balanced inner valve design exposes both sides of the inner valve to essentially the same pressure. This eliminates much of the effect that changes in inlet pressure might have on inner valve position and orifice opening. Regulator Operation In a typical regulator, an inner valve sets the size of an orifice which connects inlet port to outlet port. The sensing element, often a diaphragm or piston mechanically linked to the inner valve, reacts to downstream pressure and a reference force to position the inner valve. The reference force can be a spring, or an air pilot chamber. The valve is normally open. High pressure air enters and flows through the orifice toward the outlet. ownstream pressure is connected through an aspirator tube to the bottom of the diaphragm. s downstream pressure increases, the diaphragm is forced upward, compressing the adjustment spring. When the diaphragm moves, the inner valve spring pushes the inner valve disc upward to throttle the orifice. If downstream pressure exhausts, the mechanical sequence reverses and the inner valve disc opens the orifice until the set pressure is reached again. The arrangement of separate diaphragm chamber and aspirator tube accomplishes two purposes. First, the diaphragm is moved out of the potentially abrasive air stream. Second, and more important, if the downstream system calls for high flow, this flow generates a low pressure venturi effect at the end of the aspirator tube and into the diaphragm chamber. The diaphragm therefore reacts more quickly to open the orifice via the inner valve, thereby improving response time to high flow demands. Some circuits may be subject to downstream-generated high pressure (from high temperatures or heavy vertical loads on cylinders, for example). This high pressure is reduced by a self-relieving feature built into the regulator. The inner valve stem normally blocks a relieving orifice in the center of the diaphragm. If excessive pressure lifts the diaphragm off the stem, air bleeds through the orifice and out the spring cage vent until the system returns to the set pressure.

23 8 6 psi 6 Catalog (Revised //) General Information Compressed ir Treatment Regulators Regulators Regulator Comparison Chart Precision Standard High Precision Regulators Regulator Regulator Examples > R R R R6 R, R, R9 Repeatability / Sensitivity Regulator s ability to return to a set. PSIG. PSIG. PSIG. to to pressure after inducing flow. /8" Water Column /8" Water Column /" Water Column. PSIG PSIG Reduced This refers to the regulator s ability est est etter Good verage Pressure to maintain a consistent output Variation pressure when faced with variables such as time, cycling, temperature, supply pressure, flow, etc. Input Pressure Unregulated air pressure going PSIG Max. PSIG Max. PSIG Max. Varies Varies into the regulator Effect of Supply Reduced / set pressure variation. PSIG. PSIG. PSIG PSIG pprox. Pressure Variation when input pressure changes by - 6 PSIG on Regulated Pressure PSIG Reduced Pressure Reduced pressure ranges available - PSIG - PSIG - PSIG Varies Varies Range - PSIG - PSIG -6 PSIG - PSIG Flow Capacity Regulator s flow capacity SCFM SCFM 8 SCFM Varies Varies Exhaust (Relief) Capacity Regulator s exhaust/relief flow SCFM SCFM SCFM Low Low rating when backpressure is introduced from downstream Overpressure to Relieve Regulator s sensitivity to relieve est est etter Good verage *Key in cylinder applications excess downstream pressure over (. PSIG) (. PSIG) (. PSIG) ( PSIG) (- PSIG) the set pressure. Constant leed oes the regulator constantly bleed Yes Yes Yes Varies No air to the atmosphere to maintain accuracy? Size Constraints Overall size of regulator." H x.6" W." H x.6" W." H x " W Varies Varies Mounting Constraints Mounting options Panel, Pipe, Panel, Pipe, Panel, Pipe, Panel, Pipe, Varies or racket or racket or racket racket, or Modular Port Size Inlet / Outlet port size /" /" /" or /8" Varies Varies T-handle djusting Screw Lock Nut Use This Gauge For Setting Reduced Pressure Spring utton Control Spring Spring Cage IN OUT Pilot Regulator pplication Pilot Port iaphragm ssembly iaphragm ssembly IN Innervalve ssembly OUT ody Spring, ottom ottom Plug IN Innervalve ssembly OUT ody Spring, ottom ottom Plug Standard Regulator Pilot Operated Regulator

24 E N T Catalog R / R Series (Revised //) General Purpose Regulators /, /8 & / Inch Ports R / R General Purpose Regulators Features High Flow Performance Featuring Rugged esign for the Most emanding pplications iaphragm Operated esign with alanced Poppet esign for Quick and ccurate Regulation ccurate Pressure Regulation Panel Mountable High Flow: /" - 8 SCFM /8" - 8 SCFM /" - SCFM R: Push-to-Lock, Pull-to-djust. djusting Lock is engaged when Knob is Removed Rendering Unit Tamper Resistant R: Heavy uty Tee Handle djustment SCFM = Standard cubic feet per minute at PSIG inlet, 7 PSIG no flow secondary setting, and PSIG pressure drop. Port Size R NPT R NPT Relieving Relieving Without Gauge - PSIG Reduced Pressure /" R-C R-C /8" R-C R-C /" R-C R-C With Gauge - PSIG Reduced Pressure /" R-CG R-CG /8" R-CG R-CG /" R-CG R-CG Standard part numbers shown bold. For other models refer to ordering information below. N R C E P T P - U L L R Regulator imensions C E N R (7) (6) (86) (9) () () R (7) (6) () (9) (6) () inches (mm) NOTE:.7 ia. (mm) hole required for panel mounting.! WRNING o not connect regulator to bottled gas. o not exceed maximum primary pressure rating. Product rupture can cause serious injury. + K L O C N R C E Ordering Information R C /** Series Tamper Resistant, Snap Lock, Removable Knob T Handle djustment CUTION: Port Threads NPT G SPP Port Size / Inch /8 Inch / Inch REGULTOR PRESSURE JUSTMENT The working range of knob adjustment is designed to permit outlet pressures within their full range. Pressure adjustment beyond this range is also possible because the knob is not a limiting device. This is a common characteristic of most industrial regulators, and limiting devices may be obtained only by special design. NOTE: OL OPTIONS RE STNR. Reduced Pressure Range - PSIG -6 PSIG C - PSIG - PSIG Options G Gauge K Non-Relieving P Panel Mount Nut X6 Fluorocarbon O-Rings and iaphragm N Panel Mount Threads at Top of onnet (R Only) X8 rass ody Engineering Change esignator Will be entered at factory.

25 Catalog (Revised //6) Technical Specifications R / R R / R Series General Purpose Regulators Technical Information Secondary Pressure - bar 6 Secondary Pressure - PSIG 7 R-C / R-C / & /8 Inch Ports PSIG (6.9 bar) Primary Pressure Secondary Pressure - bar 6 Secondary Pressure - PSIG 7 R-C / Inch Ports PSIG (6.9 bar) Primary Pressure Rated 6 8 Rated Flow - dm n /s Flow - dm n /s R / R Regulator Kits & ccessories Control Knob (R)... RY Tee Handle (R)... S6Y Gauges " ial Size, /" ack Connection to 6 PSIG ( to kpa)... KN6 " ial Size, /" ack Connection to 6 PSIG ( to kpa)... KN6 " ial Size, /" ack Connection to PSIG ( to 68 kpa)... KN Mounting racket Kit... SRY7 Panel Mount Nut Plastic... RX-P luminum... RX- Repair Kits Non-Relieving... RKRKY Non-Relieving (Viton)...RKRKYX6 Relieving... RKRY Relieving (Viton)... RKRYX6 Cage Kit R... CKRY R... CKRY Specifications Gauge Ports ().../ Inch Port Threads.../, /8, / Inch Supply Pressure... PSIG Maximum (. bar) Temperature Rating... F to F (. C to C) Weight.... lb. (.9 kg) / Unit lb. (. kg) / -Unit Master Pack Materials of Construction djusting Knob R... cetal R (Tee Handle)... Steel ody...zinc ottom Plug... rass Elastomers... una N Spring Case R... cetal R...Zinc

26 Catalog R9 Series Standard Regulators /, /8 & / Inch Ports R9 Standard Regulators Features High Flow Performance Featuring Rugged esign for the Most emanding pplications IN OUT Ideal for Those Installations Calling for Constant Pressure with Wide Variation in Flow X8 Reverse Flow Option iaphragm Operated esign with alanced Poppet esign for Quick and ccurate Regulation Secondary spiration Plus alanced Poppet Provides Quick Response and ccurate Pressure Regulation Heavy uty Tee Handle djustment Reverse Flow Version vailable Panel Mount Version vailable High Flow: /" - SCFM /8" - SCFM /" - SCFM SCFM = Standard cubic feet per minute at PSIG inlet, 7 PSIG no flow secondary setting, and PSIG pressure drop..6 ia.,8 Ø Panel Mount Version N C E Port Size NPT SPP Relieving Relieving Without Gauge - PSIG Reduced Pressure /" R9-C R9GC /8" R9-C R9GC /" R9-C R9GC With Gauge - PSIG Reduced Pressure /" R9-CG /8" R9-CG /" R9-CG Standard part numbers shown bold. For other models refer to ordering information below. R9 Regulator imensions C E N R9-C, R9-C (76) () (7) (7) () () R9-C (9) () () (8) (7) () inches (mm)! WRNING o not connect regulator to bottled gas. o not exceed maximum primary pressure rating. Product rupture can cause serious injury. Ordering Information R 9 C /** Port Threads NPT G SPP Port Size / Inch /8 Inch / Inch NOTE: OL OPTIONS RE STNR. Reduced Pressure Range - PSIG -6 PSIG C - PSIG - PSIG CUTION: REGULTOR PRESSURE JUSTMENT The working range of knob adjustment is designed to permit outlet pressures within their full range. Pressure adjustment beyond this range is also possible because the knob is not a limiting device. This is a common characteristic of most industrial regulators, and limiting devices may be obtained only by special design. Options G Gauge K Non-Relieving P Panel Mount Version X6 Fluorocarbon O-Rings and iaphragm X8 Reverse Flow* * Reverse flow for use downstream of control valves. Engineering Change esignator Will be entered at factory.

27 Catalog (Revised //) Technical Specifications R9 R9 Series Standard Regulators Technical Information Secondary Pressure - bar 6 Secondary Pressure - PSIG 8 6 R9-C / Inch Ports PSIG (6.9 bar) Primary Pressure Secondary Pressure - bar 6 Secondary Pressure - PSIG 7 R9-C /8 Inch Ports PSIG (6.9 bar) Primary Pressure 6 8 Flow - dm n /s Secondary Pressure - bar 6 Secondary Pressure - PSIG 7 R9-C Flow - dm n /s / Inch Ports PSIG (6.9 bar) Primary Pressure Flow - dm n /s R9 Regulator Kits & ccessories Gauges " ial Size, /" ack Connection to 6 PSIG ( to kpa)... 7Y6S " ial Size, /" ack Connection to 6 PSIG ( to kpa)... 7Y6S " ial Size, /" ack Connection to PSIG ( to 68 kpa)... 7YS Mounting racket Kit /", /8"... SY7 /" Panel Mount Conversion Kit /", /8"... /"... Repair Kits Non-Relieving iaphragm, Valve ssembly (/", /8"; ll PSIG)... RK8Y Relieving iaphragm, Valve ssembly (/", /8"; ll PSIG)... RK9Y Non-Relieving iaphragm, Valve ssembly (/";, 6, PSIG)... RK8 Non-Relieving iaphragm, Valve ssembly (/"; PSIG)... RK8 Relieving iaphragm, Valve ssembly (/";, 6, PSIG)... RK9 Relieving iaphragm, Valve ssembly (/"; PSIG)... RK9 For Fluorocarbon Repair Kits, add X6 to Kit Number suffix. Specifications Gauge Ports ()... / Inch Port Threads... /, /8, / Inch Reduced Pressure Range... to PSIG (. to 8. bar) Supply Pressure... PSIG Maximum (. bar) Temperature Rating... F to F (. C to C) Weight R9-, R lb. (.8 kg) / Unit 6 lb. (.79 kg) / -Unit Master Pack R lb. (. kg) / Unit 7 lb. (. kg) / 8-Unit Master Pack Materials of Construction djusting Screw, Springs... Steel ody, Spring Cage... Zinc ottom Plug, Innervalve... rass Seals... una N

28 Catalog R9 Series Standard Regulators /,, -/ & -/ Inch Ports R9 Standard Regulators Features High Flow Performance Featuring Rugged esign for the Most emanding pplications Ideal for Those Installations Calling for Constant Pressure with Wide Variation in Flow iaphragm Operated esign with alanced Poppet esign for Quick and ccurate Regulation Secondary spiration Plus alanced Poppet Provides Quick Response and ccurate Pressure Regulation Heavy uty Tee Handle djustment Reverse Flow Version vailable High Flow: /" - SCFM " - SCFM -/" & -/" - SCFM SCFM = Standard cubic feet per minute at PSIG inlet, 7 PSIG no flow secondary setting, and PSIG pressure drop. IN X8 Reverse Flow Option N C OUT E NPT SPP Port Size Relieving Relieving Without Gauge - PSIG Reduced Pressure /" R9-6C R9G6C " R9-8C R9G8C -/" R9-C R9GC -/" R9-C R9GC With Gauge - PSIG Reduced Pressure /" R9-6CG " R9-8CG -/" R9-CG -/" R9-CG Standard part numbers shown bold. For other models refer to ordering information below. R9 Regulator imensions C E N R9-6C, R9-8C (9) (7) (7) () () () R9-C, R9-C () (6) (7) () (6) (.6) inches (mm)! WRNING o not connect regulator to bottled gas. o not exceed maximum primary pressure rating. Product rupture can cause serious injury. Ordering Information R 9 6 C /** Port Threads NPT G SPP Port Size 6 / Inch 8 Inch -/ Inch Reduced Pressure Range C - PSIG - PSIG -/ Inch CUTION REGULTOR PRESSURE JUSTMENT The working range of knob adjustment is designed to permit outlet pressures within their full range. Pressure adjustment beyond this range is also possible because the knob is not a limiting device. This is a common characteristic of most industrial regulators, and limiting devices may be obtained only by special design. NOTE: OL OPTIONS RE STNR. 6 Options G Gauge K Non-Relieving X6 Fluorocarbon O-Rings and iaphragm X8 Reverse Flow* * Reverse flow for use downstream of control valves. Engineering Change esignator Will be entered at factory.

29 Catalog (Revised //) Technical Specifications R9 R9 Series Standard Regulators Technical Information Secondary Pressure - bar 6 Secondary Pressure - PSIG 7 R9-6C / Inch Ports PSIG (6.9 bar) Primary Pressure Flow - dm n /s Secondary Pressure - bar 6 Secondary Pressure - PSIG 7 R9-8C Inch Ports PSIG (6.9 bar) Primary Pressure Flow - dm n /s Secondary Pressure - bar 6 Secondary Pressure - PSIG 7 R9-C -/ Inch Ports PSIG (6.9 bar) Primary Pressure Secondary Pressure - bar 6 Secondary Pressure - PSIG 7 R9-C -/ Inch Ports PSIG (6.9 bar) Primary Pressure 8 6 Flow - dm n /s 8 6 Flow - dm n /s R9 Regulator Kits & ccessories Gauges " ial Size, /" ack Connection to 6 PSIG ( to kpa)... 7Y6S " ial Size, /" ack Connection to 6 PSIG ( to kpa)... 7Y6S " ial Size, /" ack Connection to PSIG ( to 68 kpa)... 7YS Mounting racket Kit Repair Kits Non-Relieving iaphragm, Valve ssembly (/", ")... RK8 Non-Relieving iaphragm, Valve ssembly (-/", -/")... RK8 Relieving iaphragm, Valve ssembly (/", ")... RK9 Relieving iaphragm, Valve ssembly (-/", -/")... RK9 For Fluorocarbon Repair Kits, add X6 to Kit Number suffix. Specifications Gauge Ports ()... / Inch Port Threads... /,, -/, -/ Inch Reduced Pressure Range... to PSIG (. to 8. bar) Supply Pressure... PSIG Maximum (. bar) Temperature Rating... F to F (. C to C) Weight R9-6, R lb. (.8 kg) / Unit lb. (. kg) / -Unit Master Pack R9-, R lb. (.7 kg) / Unit 9 lb. (. kg) / -Unit Master Pack Materials of Construction djusting Screw, Springs... Steel ody, Spring Cage... Zinc ottom Plug, Innervalve... rass Seals... una N 7

30 Catalog R9 Series Pilot Operated Regulators /, /8 & / Inch Ports R9 Pilot Operated Regulators Features dapted for Control by a Remote or istant Small Pilot Regulator. Ideal for Maximum Capacity Requirements in pplications where Units are Not Readily ccessible High Flow Performance Featuring Rugged esign for the Most emanding pplications Ideal for Those Installations Calling for Constant Pressure with Wide Variation in Flow iaphragm Operated esign with alanced Poppet and Constant leed Pilot for Quick and ccurate Regulation. Secondary spiration Plus alanced Poppet Provides Quick Response and ccurate Pressure Regulation Reverse Flow vailable High Flow: /" - SCFM /8" - SCFM /" - SCFM SCFM = Standard cubic feet per minute at PSIG inlet, 7 PSIG no flow secondary setting, and PSIG pressure drop. N C E NPT SPP Port Size Relieving Relieving Without Gauge - PSIG Reduced Pressure /" R9-J R9GJ /8" R9-J R9GJ /" R9-J R9GJ Standard part numbers shown bold. For other models refer to ordering information below. R9 Regulator imensions C E N R9-J, R9-J (76) () () (7) (88) () R9-J (9) () (9) (8) (98) (9) inches (mm)! WRNING o not connect regulator to bottled gas. o not exceed maximum primary pressure rating. Product rupture can cause serious injury. Ordering Information R 9 J /** Port Threads NPT G SPP Port Size / Inch /8 Inch / Inch Reduced Pressure Range J ir Pilot Operated Options K Non-Relieving X6 Fluorocarbon O-Rings and iaphragm X7 Non-leed Pilot (For use with Electronic Controllers) Engineering Change esignator Will be entered at factory. NOTE: OL OPTIONS RE STNR. 8

31 Catalog (Revised //) Technical Specifications R9 R9 Series Pilot Operated Regulators Technical Information Secondary Pressure - bar 6 Secondary Pressure - PSIG 7 R9-J / Inch Ports PSIG (6.9 bar) Primary Pressure Secondary Pressure - bar 6 Secondary Pressure - PSIG 7 R9-J /8 Inch Ports PSIG (6.9 bar) Primary Pressure 6 8 Flow - dm n /s Secondary Pressure - bar 6 Secondary Pressure - PSIG 7 R9-J Flow - dm n /s / Inch Ports PSIG (6.9 bar) Primary Pressure Flow - dm n /s R9 Regulator Kits & ccessories Gauges " ial Size, /" ack Connection to 6 PSIG ( to kpa)... 7Y6S " ial Size, /" ack Connection to 6 PSIG ( to kpa)... 7Y6S " ial Size, /" ack Connection to PSIG ( to 68 kpa)... 7YS Repair Kits Non-Relieving iaphragm, Valve ssembly (/")... RK8X Non-Relieving iaphragm, Valve ssembly (/", /8")... RK8XY Relieving iaphragm, Valve ssembly (/")... RK9X Relieving iaphragm, Valve ssembly (/", /8")... RK9XY For Fluorocarbon Repair Kits, add X6 to Kit Number suffix. 9 Specifications Gauge Ports ()... / Inch Port Threads... /, /8, / Inch Reduced Pressure Range djustable to within to 7 PSIG of Supply Pressure Supply Pressure... PSIG Maximum (. bar) ir Consumption Constant bleed from air pilot chamber: approx..7 SCFM ( SCFH) Temperature Rating... F to F (. C to C) Weight R9-J, R9-J....6 lb. (.7 kg) / Unit 9 lb. (8.6 kg) / -Unit Master Pack R9-J....6 lb. (.8 kg) / Unit lb. (9. kg) / 8-Unit Master Pack Materials of Construction ody, Ring, Top Plate... Zinc ottom Plug, Innervalve... rass Seals... una N

32 Catalog R9 Series Pilot Operated Regulators /,, -/ & -/ Inch Ports R9 Pilot Operated Regulators Features dapted for Control by a Remote or istant Small Pilot Regulator. Ideal for Maximum Capacity Requirements in pplications where Units are Not Readily ccessible High Flow Performance Featuring Rugged esign for the Most emanding pplications Ideal for Those Installations Calling for Constant Pressure with Wide Variation in Flow iaphragm Operated esign with alanced Poppet and Constant leed Pilot for Quick and ccurate Regulation. Secondary spiration Plus alanced Poppet Provides Quick Response and ccurate Pressure Regulation Reverse Flow Version vailable High Flow: /", " - SCFM, -/" & -/" - 8+ SCFM SCFM = Standard cubic feet per minute at PSIG inlet, 7 PSIG no flow secondary setting, and PSIG pressure drop. N E C NPT Port Size Relieving Without Gauge - PSIG Reduced Pressure SPP Relieving /" R9-6J R9G6J " R9-8J R9G8J -/" R9-J R9GJ -/" R9-J R9GJ Standard part numbers shown bold. For other models refer to ordering information below. R9 Regulator imensions C E N R9-6J, R9-8J () (7) (7) () () (6) R9-J, R9-J () (6) (8) () () (7) inches (mm)! WRNING o not connect regulator to bottled gas. o not exceed maximum primary pressure rating. Product rupture can cause serious injury. Ordering Information R 9 6 J /** Port Threads NPT G SPP Port Size 6 / Inch 8 Inch -/ Inch -/ Inch Reduced Pressure Range J ir Pilot Operated Options K Non-Relieving X6 Fluorocarbon O-Rings and iaphragm X7 Non-leed Pilot (For use with Electronic Controllers) Engineering Change esignator Will be entered at factory. NOTE: OL OPTIONS RE STNR.

33 Catalog (Revised //) Technical Specifications R9 R9 Series Pilot Operated Regulators Technical Information Secondary Pressure - bar 6 Secondary Pressure - PSIG 7 R9-6J / Inch Ports PSIG (6.9 bar) Primary Pressure Secondary Pressure - bar 6 Secondary Pressure - PSIG 7 R9-8J Inch Ports PSIG (6.9 bar) Primary Pressure Flow - dm n /s Flow - dm n /s Secondary Pressure - bar 6 Secondary Pressure - PSIG 7 R9-C -/ Inch Ports PSIG (6.9 bar) Primary Pressure Secondary Pressure - bar 6 Secondary Pressure - PSIG 7 R9-C -/ Inch Ports PSIG (6.9 bar) Primary Pressure 8 6 Flow - dm n /s 8 6 Flow - dm n /s R9 Regulator Kits & ccessories Gauges " ial Size, /" ack Connection to 6 PSIG ( to kpa)... 7Y6S " ial Size, /" ack Connection to 6 PSIG ( to kpa)... 7Y6S " ial Size, /" ack Connection to PSIG ( to 68 kpa)... 7YS Repair Kits Non-Relieving iaphragm, Valve ssembly (/", ")... RK8X Non-Relieving iaphragm, Valve ssembly (-/", -/")... RK8X Relieving iaphragm, Valve ssembly (/", ")... RK9X Relieving iaphragm, Valve ssembly (-/", -/")... RK9X For Fluorocarbon Repair Kits, add X6 to Kit Number suffix. Specifications Gauge Ports ()... / Inch Port Threads... /,, -/, -/ Inch Reduced Pressure Range djustable to Within to 7 PSIG of Supply Pressure Supply Pressure... PSIG Maximum (. bar) ir Consumption Constant bleed from air pilot chamber: approx.7 SCFM ( SCFH) Temperature Rating... F to F (. C to C) Weight R9-6J, R9-8J.... lb. (.6 kg) / Unit lb. (9. kg) / 8-Unit Master Pack R9-J, R9-J....6 lb. (. kg) / Unit 6 lb. (.87 kg) / 8-Unit Master Pack Materials of Construction ody, Ring, Top Plate... Zinc ottom Plug, Innervalve... rass Seals... una N

34 Catalog R9 Series (Revised //) Pilot Operated Regulators & -/ Inch Ports R9 Pilot Operated Regulators Features dapted for Control by a Remote or istant Small Pilot Regulator. Ideal for Maximum Capacity Requirements in pplications where Units are Not Readily ccessible High Flow Performance Featuring Rugged esign for the Most emanding pplications Ideal for Those Installations Calling for Constant Pressure with Wide Variation in Flow Piston Operated esign with alanced Poppet and ual Constant leed for Quick and ccurate Regulation High Flow: " & -/" - + SCFM SCFM = Standard cubic feet per minute at PSIG inlet, 7 PSIG no flow secondary setting, and PSIG pressure drop. C E NPT Port Size Relieving Without Gauge - PSIG Reduced Pressure SPP Relieving " R9-6J R9G6J -/" R9-J R9GJ Standard part numbers shown bold. For other models refer to ordering information below. R9 Regulator imensions C E R9-6J, R9-J (68) (79) (7) (8) (76) inches (mm)! WRNING o not connect regulator to bottled gas. o not exceed maximum primary pressure rating. Product rupture can cause serious injury. Ordering Information R 9 6 J Port Threads NPT G SPP Port Size 6 Inch -/ Inch Reduced Pressure Range J ir Pilot Operated NOTE: Non-Relieving Not vailable. NOTE: OL OPTIONS RE STNR.

35 Catalog (Revised //) Technical Specifications R9 R9 Series Pilot Operated Regulators Technical Information Secondary Pressure - bar 6 Secondary Pressure - PSIG 7 R9-6J, R9-J Inch Ports PSIG (6.9 bar) Primary Pressure Flow - dm n /s R9 Regulator Kits & ccessories Gauges " ial Size, /" ack Connection to 6 PSIG ( to kpa)... 7Y6S " ial Size, /" ack Connection to 6 PSIG ( to kpa)... 7Y6S " ial Size, /" ack Connection to PSIG ( to 68 kpa)... 7YS Repair Kits Piston Type Regulation (", -/")... RK9G Specifications Gauge Ports ()... / Inch (Can be used for Full Flow) High Pressure Outlet for Pilot (Not seen in photo)... / Inch Port Threads..., -/ Inch Reduced Pressure Range djustable to Within to 7 PSIG of Supply Pressure Supply Pressure... PSIG Maximum (. bar) ir Consumption Constant leed from ir Pilot Chamber: pprox..7scfm (SCFM) Constant leed from Reduced Pressure: pprox..7scfm (SCFM) Temperature Rating... F to F (. C to C) Weight R9-6J, R9-J... lb. (6.8 kg) / Unit lb. (6.8 kg) / -Unit Master Pack Materials of Construction ody, Piston... luminum Seals... una N Innervalve... rass & Stainless

36 Catalog WR Series (Revised 8--6) ial Regulators / Inch Ports WR ial Regulator Relieving Features Pressure Reference Indicating ial Face Non-rising, Pressure-adjustment Knob Self-relieving Full Pressure djustment in Less than One Full Turn Recommended for Pilot-air pplications Flow Capacity: /".7 SCFM SCFM = Standard cubic feet per minute at PSIG inlet, 9 PSIG no flow secondary setting, and PSIG pressure drop. H C H. ia. (.6mm) G J K E Standard Pressure Low Pressure Port Size to 6 PSIG (, to bar) to PSIG (, to bar) /" WR6R WRR Standard part numbers shown; for other models refer to ordering information below.! WRNING o not connect regulator to bottled gas. o not exceed maximum primary pressure rating. Product rupture can cause serious injury. WR Regulator imensions C (7) (66) (66) E G...6 () () (9.6) H J K...8 (6) (.8) (.6) inches (mm) Ordering Information WR 6 R Port Size / Inch Springs to PSIG 6 to 6 PSIG djustment R Relieving Engineering Level Current Thread Type NPT SPP CUTION: REGULTOR PRESSURE JUSTMENT The working range of knob adjustment is designed to permit outlet pressures within their full range. Pressure adjustment beyond this range is also possible because the knob is not a limiting device. This is a common characteristic of most industrial regulators, and limiting devices may be obtained only by special design. NOTE: OL OPTIONS RE STNR.

37 Catalog Technical Specifications WR WR Series ial Regulators Technical Information 7, WR6R Secondary Pressure - ar 6,,,,,,, Secondary Pressure - PSIG 8 6 / Inch Ports Primary Pressure PSIG (6.9 bar) ir Flow Rate - dm n /s WR Regulator Kits & ccessories djustment ial Knob... RRP-6--8 O-ring, Repair Kit...GRP Piston and onnet Repair Kit... RRP Spring, Regulation, elleville Washer to PSIG (76 kpa)... RRP to 6 PSIG ( kpa)... RRP Tamper Resistant Kit... RRP Valve, Pilot with O-ring and Valve Spring... RRP Specifications djusting Range Pressure... to PSIG ( to 76 kpa) to 6 PSIG ( to kpa) leed Rate.... SCFM Maximum Operating Temperature... F (6. C) Maximum Supply Pressure... PSIG (68 kpa) Port Threads... /" Weight.... lb. (. kg) Materials of Construction ody... Zinc onnet... Zinc / rass Piston... cetal Seals... Nitrile Springs... Steel Valve ssembly... rass / Nitrile / cetal

38 Catalog WR Series (Revised 8--6) ial Regulators /, /8, / & / Inch Ports WR ial Regulator Relieving Features alanced Poppet esign Non-rising, Pressure-adjusting ial High-relief Flow (/6" Relief Orifice) Two /" Gauge Ports H. ia. (.6mm) Piston Operated Flow Capacity: /" 7 SCFM /8" 8 SCFM /" 9 SCFM /" SCFM SCFM = Standard cubic feet per minute at PSIG inlet, (/, / & /) 9 PSIG, (/8) 8 PSIG no flow secondary setting, and PSIG pressure drop. C H G L K J E F High Flow Low Pressure Port Size to 6 PSIG (, to bar) to PSIG (, to bar) /" WR6R WRR /8" WR6R WRR /" WR6R WRR /" WR6R WRR Standard part numbers shown; for other models refer to ordering information below.! WRNING o not connect regulator to bottled gas. o not exceed maximum primary pressure rating. Product rupture can cause serious injury. Ordering Information WR Regulator imensions C...6 () (8) (66) E F.9.6. () (7) (9) G H J.7..8 (69) (6) (.8) K L.8.7 (.6) (.6) inches (mm) WR 6 R Port Size / Inch /8 Inch / Inch / Inch Springs to PSIG 6 to 6 PSIG djustment R Relieving Engineering Level Current Thread Type NPT SPP CUTION: REGULTOR PRESSURE JUSTMENT The working range of knob adjustment is designed to permit outlet pressures within their full range. Pressure adjustment beyond this range is also possible because the knob is not a limiting device. This is a common characteristic of most industrial regulators, and limiting devices may be obtained only by special design. NOTE: OL OPTIONS RE STNR. 6

39 Catalog Technical Specifications WR WR Series ial Regulators Technical Information Secondary Pressure - ar 7, 6,,,,,,, Secondary Pressure - PSIG 8 6 WR6R / Inch Ports Primary Pressure PSIG (6.9 bar) 6 8 Secondary Pressure - ar 7, 6,,,,,, Secondary Pressure - PSIG 8 6 WR6R /8 Inch Ports Primary Pressure PSIG (6.9 bar) ir Flow Rate - dm n /s ir Flow Rate - dm n /s Secondary Pressure - ar 7, 6,,,,,, Secondary Pressure - PSIG 8 6 WR6R / Inch Ports Primary Pressure PSIG (6.9 bar) Secondary Pressure - ar 7, 6,,,,,, Secondary Pressure - PSIG 7 WR6R / Inch Ports Primary Pressure PSIG (6.9 bar) 7 ir Flow Rate - dm n /s 7 ir Flow Rate - dm n /s WR Regulator Kits & ccessories djustment ial Knob... RRP-6--8 O-ring, Repair Kit...GRP Piston ottom and O-ring Seal... RRP Pistons and onnet Repair Kit... RRP Spring, Regulation, elleville Washer to PSIG Range... RRP to 6 PSIG Range... RRP Tamper Resistant Kit... RRP Valve, Main with U-Cup Seal & ottom Plug... RRP Valve, Main with U-Cup Seal... RRP-9--8 Valve, Pilot with O-ring and Valve Spring... RRP Specifications djusting Range Pressure... to PSIG ( to 76 kpa) to 6 PSIG ( to kpa) leed Rate.... SCFM Gauge Ports... Two Ports /" (Can be used as additional High Flow / Inch Outlet Ports) Maximum Operating Temperature... F (6. C) Maximum Supply Pressure... PSIG (68 kpa) Port Threads... /", /8", /", /" Weight.... lb. (. kg) Materials of Construction ody... Zinc onnet... Zinc / rass Piston... cetal Seals... Nitrile Springs... Steel Valve ssembly... rass / Nitrile / cetal 7

40 Catalog WR Series (Revised 8--6) ial Regulators /, & -/ Inch Ports WR ial Regulator Relieving Features alanced Poppet esign H. ia. (.6mm) Non-rising, Pressure-adjusting ial. High-relief Flow (/6" Relief Orifice) H Two /" Gauge Ports Piston Operated. C G Flow Capacity: /" SCFM " 6 SCFM -/" 7 SCFM SCFM = Standard cubic feet per minute at PSIG inlet, 9 PSIG no flow secondary setting, and PSIG pressure drop. E F J High Flow Low Pressure Port Size to 6 PSIG (. to bar) to PSIG (. to bar) /" WR6R WRR " WR6R WRR -/" WR66R WR6R Standard part numbers shown; for other models refer to ordering information below.! WRNING o not connect regulator to bottled gas. o not exceed maximum primary pressure rating. Product rupture can cause serious injury. WR Regulator imensions C...6 () (9) (66) E F.7.. () () (9) G H J... (76) (6) () inches (mm) Ordering Information WR 6 R Port Size / Inch Inch 6 -/ Inch Springs to PSIG 6 to 6 PSIG djustment R Relieving Engineering Level Current Thread Type NPT SPP CUTION: REGULTOR PRESSURE JUSTMENT The working range of knob adjustment is designed to permit outlet pressures within their full range. Pressure adjustment beyond this range is also possible because the knob is not a limiting device. This is a common characteristic of most industrial regulators, and limiting devices may be obtained only by special design. NOTE: OL OPTIONS RE STNR. 8

41 Catalog Technical Specifications WR WR Series ial Regulators Technical Information Secondary Pressure - ar 7, 6,,,,,,, Secondary Pressure - PSIG 8 6 WR6R / Inch Ports Primary Pressure PSIG (6.9 bar) Secondary Pressure - ar 7, 6,,,,,,, Secondary Pressure - PSIG 8 6 WR6R Inch Ports Primary Pressure PSIG (6.9 bar) ir Flow Rate - dm 6 8 n /s ir Flow Rate - dm n /s Secondary Pressure - ar 7, 6,,,,,, Secondary Pressure - PSIG 8 6 WR66R -/ Inch Ports Primary Pressure PSIG (6.9 bar) ir Flow Rate - dm n /s WR Regulator Kits & ccessories djustment ial Knob... RRP-6--8 O-ring, Repair Kit... GRP Piston, ottom and O-ring Seal... RRP Pistons and onnet Repair Kit... RRP Spring, Regulation, elleville Washer to PSIG Range... RRP to 6 PSIG Range... RRP Tamper Resistant Kit... RRP Valve, Main with O-ring Seal... RRP-9--8 Valve, Pilot with O-ring and Valve Spring... RRP Specifications djusting Range Pressure... to PSIG ( to 76 kpa) to 6 PSIG ( to kpa) leed Rate.... SCFM Gauge Ports... Two Ports /" (Can be used as additional High Flow / Inch Outlet Ports) Maximum Operating Temperature... F (6. C) Maximum Supply Pressure... PSIG (68 kpa) Port Threads... /", ", -/" Weight.... lb. (.8 kg) Materials of Construction ody... Zinc onnet... Zinc / rass Piston... cetal Seals... Nitrile Springs... Steel Valve ssembly... rass / Nitrile / cetal 9

42 Catalog WR Series (Revised 8--6) ial Regulators -/ & Inch Ports WR ial Regulator Relieving Features alanced Poppet esign Non-rising, Pressure-adjusting ial High-relief Flow (/6" Relief Orifice) Two /" Gauge Ports Piston Operated Flow Capacity: -/",6 SCFM ",6 SCFM E G C SCFM = Standard cubic feet per minute at PSIG inlet, 9 PSIG no flow secondary setting, and PSIG pressure drop. F High Flow Low Pressure Port Size to 6 PSIG (. to bar) to PSIG (. to.8 bar) -/" WR76R WR7R " WR86R WR8R Standard part numbers shown; for other models refer to ordering information below.! WRNING o not connect regulator to bottled gas. o not exceed maximum primary pressure rating. Product rupture can cause serious injury. WR Regulator imensions C (7) () (9) E F.8..8 (7) (9) (89) G. () inches (mm) Ordering Information WR 7 6 R Port Size 7 -/ Inch 8 Inch Springs to PSIG 6 to 6 PSIG djustment R Relieving Engineering Level Current Thread Type NPT SPP CUTION: REGULTOR PRESSURE JUSTMENT The working range of knob adjustment is designed to permit outlet pressures within their full range. Pressure adjustment beyond this range is also possible because the knob is not a limiting device. This is a common characteristic of most industrial regulators, and limiting devices may be obtained only by special design. NOTE: OL OPTIONS RE STNR.

43 Catalog Technical Specifications WR WR Series ial Regulators Technical Information Secondary Pressure - ar 7, 6,,,,,, Secondary Pressure - PSIG 8 6 WR76R -/ Inch Ports Primary Pressure PSIG (6.9 bar) ir Flow Rate - dm n /s Secondary Pressure - ar 7, 6,,,,,, Secondary Pressure - PSIG 8 6 WR86R Inch Ports Primary Pressure PSIG (6.9 bar) ir Flow Rate - dm n /s WR Regulator Kits & ccessories djustment ial Knob... RRP-6--8 O-ring, Repair Kit... GRP Piston, ottom and O-ring Seal... RRP Pistons and onnet Repair Kit... RRP Spring, Regulation, elleville Washer to PSIG Range... RRP to 6 PSIG Range... RRP Spring, Main Valve... RRP-9--8 Tamper Resistant Kit... RRP Valve, Main with O-ring Seal... RRP-9--8 Valve, Pilot with O-ring and Valve Spring... RRP Specifications djusting Range Pressure... to PSIG ( to 76 kpa) to 6 PSIG ( to kpa) leed Rate.... SCFM Gauge Ports... Two Ports /" (Can be used as additional High Flow / Inch Outlet Ports) Maximum Operating Temperature... F (6. C) Maximum Supply Pressure... PSIG (68 kpa) Port Threads... -/", " Weight... 9 lb. (. kg) Materials of Construction ody... Zinc onnet... Zinc / rass Piston... Zinc Seals... Nitrile Springs... Steel Valve ssembly... rass / Nitrile / cetal

44 Catalog R6 Series Precision Regulators / & /8 Inch Ports R6 Precision Regulators Features High Flow Performance Featuring Rugged esign for the Most emanding pplications Ideal for Those Installations Calling for Constant Pressure with Wide Variation in Flow iaphragm Operated with Large Surface rea and spirator for Quick and Precise Regulation Heavy uty Tee Handle djustment Panel Mount Version vailable High Flow: /" & /8" - SCFM SCFM = Standard cubic feet per minute at PSIG inlet, 7 PSIG no flow secondary setting, and PSIG pressure drop., C, & N E.688 ia. 7, Ø Max. Panel Thickness. (6,) /8" Gauge Port Port Size NPT SPP Relieving Relieving T-Handle, Without Gauge - PSIG Reduced Pressure /" R6-F R6GF /8" R6-F R6GF Hand Wheel Knob, Without Gauge - PSIG Reduced Pressure /" R6-FP R6GFP /8" R6-FP R6GFP Standard part numbers shown bold. For other models refer to ordering information below. R6 Regulator imensions C E N R6-F, R6-F (8) (.6) (8) (8) () (.) R6-FP, R6-FP (8) (.6) (8) (8) () (.) inches (mm)! WRNING o not connect regulator to bottled gas. o not exceed maximum primary pressure rating. Product rupture can cause serious injury. Ordering Information R 6 F /** Port Threads NPT G SPP CUTION: Port Size / Inch /8 Inch Reduced Pressure Range E -8 PSIG F - PSIG H - PSIG REGULTOR PRESSURE JUSTMENT The working range of knob adjustment is designed to permit outlet pressures within their full range. Pressure adjustment beyond this range is also possible because the knob is not a limiting device. This is a common characteristic of most industrial regulators, and limiting devices may be obtained only by special design. Options K Non-Relieving P Panel Mount with Knob Engineering Change esignator Will be entered at factory. NOTE: OL OPTIONS RE STNR.

45 Catalog (Revised //) Technical Specifications R6 R6 Series Precision Regulators Technical Information Secondary Pressure - bar.... Secondary Pressure - PSIG R6 / & /8 Inch Ports PSIG (6.9 bar) Primary Pressure Flow - dm n /s R6 Regulator Kits & ccessories Round Plastic Knob... 8Y Panel Mount Conversion Kit (Spring Cage, Knob, Hardware)... 6 Repair Kits Non-Relieving iaphragm, Valve ssembly (/", /8")... RK6KY Relieving iaphragm, Valve ssembly (/", /8")... RK6Y Specifications Gauge Port ()... /8 Inch Port Threads... /, /8 Inch Reduced Pressure Range... to PSIG (. to. bar) Supply Pressure... PSIG Maximum (. bar) Temperature Rating... F to F (. C to C) Weight.... lb. (. kg) / Unit 8 lb. (8.6 kg) / 8-Unit Master Pack Materials of Construction ody, Spring Cage... Zinc ottom Plug... rass Seals... una N

46 Catalog R / R Series Precision Regulators / Inch Ports R / R High Precision Regulator Features ccurate Pressure Regulation Controls Output Pressure to within.% ccuracy Multi-Stage Regulation for Maximum Control and Stability Two Full Flow Gauge Ports Super Sensitive Relief. ownstream Pressure uildup, own to. PSIG bove the Set Pressure, is utomatically Vented through Internal Relief Valve R has High Exhaust Relief Capacity C The R / R are high precision, multi-stage pressure regulators. This pressure controller provides the highest level of regulation accuracy and repeatability available and is ideal for applications that call for the utmost in control and maximum stability under variable operating conditions. stainless steel measuring capsule is used as a sensing element to activate the high gain servo balanced control mechanism in which the main valve is controlled by a pilot valve. This allows for greater accuracy and eliminates many of the problems associated with conventional regulators using range springs and diaphragms. pplications The R and R regulators are well suited for any process that requires very precise regulation of air pressure in pipes and vessels. These regulators are often used, but not limited to the following applications: ir Gauging Gas Mixing Calibration Standards ir Hoists Web Tensioning Gate ctuators Roll Loading Valve Operators Cylinder Loading R / R Regulator imensions C.6..8 () () (97). (.) inches (mm)! WRNING o not connect regulator to bottled gas. o not exceed maximum primary pressure rating. Product rupture can cause serious injury. Ordering Information Reduced Pressure Range (PSIG) Relieving to to to High Relief In / Out Ports /" R- R-C R-C

47 Catalog (Revised //) Technical Specifications R / R R / R Series High Precision Regulators Technical Information to PSIG Range Supply 9 PSIG. 9.9 Output PSIG to PSIG Range Supply 9 PSIG Flow SCFM 9.6 ().7 (.9).9 (). () ia. Thru.66 (6.8) ia. Thru () Places.9 ().8 (7).9 ().9 ()..6 () (6) Mounting racket: R / R Regulator Kits & ccessories Mounting racket Kits Pipe Mounting (Pair)... SYW7 Right ngle Mounting Service Kits - PSIG... RKR* - PSIG... RKRC* - PSIG (High Relieving)... RKRC* * Parts in Kit: iaphragms, Gasket, leed Orifice Specifications Constant leed Rate... Less than.8 SCFM (.m /hr) (Equals leed Rate plus other consumption) Total ir Consumption... 6 SCFH (.m /hr.) Effect of Supply Pressure Variation of PSIG (.7 bar) on outlet:... Less than. PSIG (. bar) Exhaust (Relief) Capacity t PSIG (. bar) above PSIG (.8 bar) Setpoint Standard Model... SCFM (.m /hr) High-Relief Model... SCFM (7m /hr) Flow Capacity t PSIG (6.89 bar) Supply, PSIG (.8 bar) Outlet... SCFM (m /hr) Gauge Ports... /" NPTF (Can be used as additional full flow /" outlet ports) Operating Pressure Range: PSIG bar PRIMRY Maximum. SECONRY Spring Pressure PSIG Minimum. Maximum.76 PSIG Minimum. Maximum 8.7 Operating Temperature Range C * to 6 C ( F* to F) * Temperatures below C ( F) require moisture free air. Repeatability / Sensitivity.... PSIG (. bar) Inches of Water Column = /8" Weight.... lb (.6 kg) Materials of Construction djusting Stem & Capsule...Stainless Steel ody... Zinc Control Knob... Plastic iaphragm(s)... una-n Seals... una-n Springs... Stainless Steel Valve Poppet... Stainless Steel

48 Catalog R Series Precision Regulators / & /8 Inch Ports R High Flow Precision Regulator Features djusting Knob. iaphragm esign for Good Repeatability, Response and Sensitivity alanced Poppet Two Full Flow Gauge Ports Precise Regulation. Will Sense a ecrease in ownstream Pressure as Small as /" of Water Column (. PSIG) High Fow Capacity. Flows of 8 SCFM ttainable with Minimal rop Stable Output. ampening ction of spiration Tube makes Regulator Insensitive to Changes in Flow On-line Maintenance. Can be Serviced Without Removal of ir Line Mounting Holes E C The R is designed for applications that require high flow capacity and accurate process control. poppet valve which is balanced by utilizing a rolling diaphragm, insures a constant output pressure even during wide supply pressure variations. Stability of regulated pressure is maintained under varying flow conditions through the use of an aspirator tube which adjusts the air supply in accordance with the flow velocity. pplications The R regulators are an ideal choice for any application that calls for accurately maintained output pressure under high flow conditions. This includes, but is not limited to such applications as: Test Equipment Gas Mixing Valve Operators Positioning Cylinders Laboratory Equipment Web Tensioning Clutch & rake Controls Roll Loading Test Panels ctuators R Regulator imensions C..8. (76) () (86) E 6.6. () (7) inches (mm)! WRNING o not connect regulator to bottled gas. o not exceed maximum primary pressure rating. Product rupture can cause serious injury. Ordering Information Reduced Pressure Range (PSIG) Relieving to to to 6 to /" R-E R- R-C R- In / Out Ports /8" N/ R- R-C R- 6

49 Catalog (Revised //) Technical Specifications R R Series High Flow Precision Regulators Technical Information Output PSIG (kpa) 8 () 7 (7) 7 (8) 6 (8) 6 () (79) () () (76) () (7) (7) () PSI Supply to PSIG ( to kpa) /8 NPT to 6 PSIG (7 to kpa) / NPT to PSIG ( to kpa) / NPT () (69) to PSIG ( to kpa) / NPT () () (8.) (7) (.) () (.) () (9.) to PSIG ( to kpa) / NPT 6 7. (8.7) ia. Thru () Places. () R.7 (6.9) ia. Thru () Places (68) Flow SCFM (m/hr) (76) (9.) (.) (7.) (8) () (9) (6).. (7) (76).7 (9). (9 ).67..C. (76) Mounting racket: ().8 () R Regulator Kits & ccessories Mounting racket Kit Service Kits Relieving to PSIG... RKRE* to PSIG... RKR* to 6 PSIG... RKRC* to PSIG... RKR* * Parts in Kit: iaphragm, Poppet, O-ring Specifications Constant leed Rate.... to. SCFH (epending upon output pressure) Gauge Ports... Two Ports /" (Can be used as additional Full Flow / Inch Outlet Ports) Effect of Supply Pressure Variation Less than. PSIG for PSIG (6.89 bar) change Exhaust (Relief) Capacity SCFM with downstream pressure PSIG above set pressure. Exhaust commences at. PSIG above set pressure. Flow Capacity t PSIG (6.89 bar) Supply, 8 PSIG (. bar) Outlet... 8 SCFM (7.8 dm /s) 7 Operating Temperature Range... - C to 7 C (- F to 6 F) Operating Pressure Range PSIG bar PRIMRY Maximum 7 Port Threads... /" Exhaust (Relief) Capacity.... SCFM (ownstream pressure PSI above set pressure) Repeatability / Sensitivity... ±. PSIG (±.68 bar) Inches of Water Column = /" Response... ms The valve will open to full flow and fill a volume of cm Weight... lb. oz. (.7 kg) Materials of Construction djusting Stem & Spring... Steel iased Spring... Stainless Steel ody, onnet... luminum Control Knob... Plastic iaphragm... una-n Elastomer and Polyester Fabric Seals... una-n Valve Poppet... rass Valve Poppet Seat... una-n

50 Catalog General Information Compressed ir Treatment Lubricators Lubricators Lubrication Many pneumatic system components and most pneumatic tools require oil lubrication for proper operation and long service life. This lubricant is typically carried by the air stream. Too little oil can cause excessive wear and premature failure. Too much oil is wasteful and can become a contaminant, particularly when carried over with the air exhaust. Intermittent lubrication may be the worst situation because the oil film can dry out to form sludges and varnishes on internal surfaces. ir line lubricators meter oil from a reservoir into the moving air stream. In general terminology, the oil droplets are usually termed a fog. For best results, the lubricator should be located as close as possible to the point where lubrication is required. How to Select the Proper Lubricator Use of proper lubricator can greatly extend the life of expensive downstream pneumatic equipment. Lubricators often are selected according to pipe size. Other selection factors are type of bowl material, bowl size, and refilling system capability. owls are available in both polycarbonate and metal. Polycarbonate offers the advantage or transparency, for simplified inspection of oil level and condition. However, caution must be exercised when using polycarbonate bowls in any area where certain chemicals are used. (Please read the warning carefully.) In addition to choice of bowls, minimum and maximum flow rates and pressure requirements should also be considered. e sure to check the pressure drop curves, to make certain the selected model will not create a higher pressure drop than the system design can tolerate. Lubricator Construction owls are available in polycarbonate and metal, subject to the same constraints discussed in the Filter Section. Transparent polycarbonate simplifies inspection of the oil level and checking for dirt and liquid condensate in the oil. Note that the system must be exhausted before removing the bowl. In some models, the system must also be exhausted before opening the fill plug to recharge the lubricator. Other designs automatically bypass the air during refilling.! Warning The plastic material used to manufacture the plastic bowls, and the sight gauge on metal bowls, may be attacked by certain chemicals. o not use this lubricator on systems with air supplied by a compressor lubricated with synthetic oils or oils containing phosphate esters or chlorinated hydrocarbons. These oils can carry over into the air lines and chemically attack and possibly rupture the bowl or sight gauge. lso, do not expose the bowls or sight gauge to materials such as carbon tetrachloride, trichlorethylene, acetone, paint thinner, cleaning fluids, or other harmful materials, for they too will cause the plastic to craze and/or rupture. For use in environments where these, or any, chemicals may be present, consult the factory for approval. Lubricator Installation The lubricators listed in this catalog should be placed before any valving and stay pressurized before, during, and after machine tool cycles. These lubricators should be placed no farther away than feet from the desired point of lubrication. 8

51 Catalog General Information Compressed ir Treatment Lubricators Lubricators Lubrication Operation Most lubricator designs include a high-velocity venturi section in the air flow path which creates a low-pressure area to draw oil from the reservoir through a capillary tube to the point of injection. There, the air stream breaks up the oil into droplets. In a typical lubricator, filtered and regulated air enters the lubricator housing and is channeled in either of two directions depending on flow rate. t low flow rates, all the air passes through the venturi where it mixes with metered oil droplets. Under higher flow conditions, the spring-loaded bypass valve opens and the excess flow bypasses the venturi, then blends with the lubricated air at a downstream point. manual adjustment (needle valve) in the housing sets the oil drip-rate into the air stream; a sight gauge allows that rate to be monitored. Fill plugs at the lubricator top provide access to refill the reservoir with oil. The bowl is removable for cleaning. djusting Knob Needle Valve ssembly Valve Seat O-ring Sight ome O-ring IN OUT ody O-ring Collar ip Tube Sight Gauge owl 9

52 o N T 7 9 U S Catalog L66 Series General Purpose Lubricators / & /8 Inch Ports L66 General Purpose Lubricators Features Metal owl with Sight Gauge - Standard Polycarbonate Sight ome owl can be Filled while ir Line is Under Pressure Proportional Oil elivery Over a Wide Range of ir Flows Large Capacity owl Precision Needle Valve ssures Repeatable Oil elivery and Provides Simple djustment of elivery Rate P 8 F 6 9 C High Flow: /" - SCFM /8" - 7 SCFM SCFM = Standard cubic feet per minute at PSIG inlet, and PSIG pressure drop. E Port Size NPT SPP No rain No rain Polycarbonate owl / Plastic Guard /" L66- L66G /8" L66- L66G Metal owl / Sight Gauge /" L66-W L66GW /8" L66-W L66GW Standard part numbers shown bold. For other models refer to ordering information below. L66 Lubricator imensions C E F L66-, L (76) () (6) (6) (77) (8) L66-W, L66-W (76) () (6) (6) (77) (8) inches (mm) Ordering Information L 66 W /** Port Threads NPT G SPP Port Size / Inch /8 Inch owl Polycarbonate with Plastic owl Guard - oz. W Metal with Sight Gauge - oz. Options H utton Head Fill Fitting X9 Manual Twist rain (Increases Product Length by 9/6 Inch) Engineering Change esignator Will be entered at factory. NOTE: OL OPTIONS RE STNR.

53 Catalog (Revised //) Technical Specifications L66 L66 Series General Purpose Lubricators Technical Information Pressure rop - bar... Pressure rop - PSIG Primary Pressure - bar Primary Pressure - PSIG 7 F66- /-inch Port 6 Pressure rop - bar... Pressure rop - PSIG Primary Pressure - bar Primary Pressure - PSIG 7 F66- /8-inch Port Flow - dm n /s Flow - dm n /s L66 Lubricator Kits & ccessories djusting Knob... 66Y7 owl Kits Polycarbonate with Plastic owl Guard ()... K66Y Zinc with Sight Gauge (W)... K69WY utton Head Fill Fitting (9/6- male thread)... S66C9 ip Tube Kit... TK66 rip Spout Kit... RK66SY Mounting racket... SF6-7 Repair Kits Needle Valve ssembly (,W)... RK66Y Sight Gauge for W owl... RK6WY Specifications owl Capacity... Ounces Port Threads... /, /8 Inch Pressure & Temperature Ratings Polycarbonate owl... to PSIG ( to. bar) F to F (. C to C) Metal owl... to PSIG ( to 7. bar) F to F (. C to 6.6 C) Weight Polycarbonate owl....8 lb. (.8 kg) / Unit lb. (6.8 kg) / 8-Unit Master Pack Metal owl.... lb. (. kg) / Unit 7.6 lb. (7.98 kg) / 8-Unit Master Pack Materials of Construction ody... Zinc owls Polycarbonate... Polycarbonate with Polyethylene Guard Metal... Zinc with Polyurethane Sight Gauge rain... rass Seals... una N Sight Gauge... Nylon

54 7 Catalog L66 Series General Purpose Lubricators / Inch Ports L66 General Purpose Lubricators Features Metal owl with Sight Gauge - Standard Polycarbonate Sight ome owl can be Filled while ir Line is Under Pressure Proportional Oil elivery Over a Wide Range of ir Flows Large Capacity owl Optional High Capacity owl(s) vailable Precision Needle Valve ssures Repeatable Oil elivery and Provides Simple djustment of elivery Rate utomatic Fill Optional (Requires External Pressurized Oil Supply) F 9 C E High Flow: /" - SCFM SCFM = Standard cubic feet per minute at PSIG inlet, and PSIG pressure drop. Port Size NPT SPP No rain No rain Polycarbonate owl / Plastic Guard /" L66- L66G Zinc owl / Sight Gauge /" L66-W L66GW luminum owl 6 oz. without Sight Gauge /" L66-E L66GE luminum owl 6 oz. with Sight Gauge /" L66-G L66GG Standard part numbers shown bold. For other models refer to ordering information below. L66 Lubricator imensions C E F L (96) (8) (9) (8) 97) (97) L66-W (96) () (9) (8) () (8) L66-E (96) (8) (9) (8) (97) (8) L66-G (7) () (6) () (6) (6) inches (mm) Ordering Information L 66 W /** Port Threads NPT G SPP Port Size / Inch owl owl Capacity escription Size 8 oz. Polycarbonate with /" Plastic owl Guard E 6 oz. Large Capacity /" without Sight Gauge G 6 oz. Large Capacity /" with Sight Gauge W 8 oz. Metal with /" Sight Gauge Options H utton Head Fill Fitting J utomatic Fill evice X9 Manual Twist rain (Increases Product Length by 9/6 Inch) Engineering Change esignator Will be entered at factory. NOTE: OL OPTIONS RE STNR.

55 8 7 Catalog (Revised //) Technical Specifications L66 L66 Series General Purpose Lubricators Technical Information 9 6 Primary Pressure - bar Primary Pressure - PSIG C Pressure rop - bar.. Pressure rop - PSIG F66-W /-inch Port 6 8 E 6 Flow - dm n /s L66-G L66 Lubricator Kits & ccessories djusting Knob... 66Y7 owl Kits luminum (E)... K6 luminum with Sight Gauge (G)... K66X Polycarbonate with Plastic owl Guard ()... K66 Zinc with Sight Gauge (W)... K69W utton Head Fill Fitting (9/6- male thread)... S66C9 ip Tube Kit... TK66 rip Spout Kit...RK66SY Mounting racket... SF6-7 Repair Kits djusting Knob (ll)... 66Y7 Needle Valve ssembly (ll)... RK66Y Sight Gauge owl Repair Kit (W)... RK6W Sight Gauge owl Repair Kit (G)... RK66X Specifications utomatic Fill Option (J) (Only available factory installed) Requires remote oil - PSIG above air pressure in bowl owl Capacity luminum (E)... 6 Ounces luminum with Polycarbonate Sight Gauge (G)... 6 Ounces Polycarbonate with Polyurethane owl Guard ()... 8 Ounces Zinc with Nylon Sight Gauge (W)... 8 Ounces Port Threads... / Inch Pressure & Temperature Ratings luminum owl (E)... to PSIG ( to. bar) F to F (. C to 6.6 C) luminum owl with Polycarbonate Sight Gauge (G)... to PSIG ( to. bar) F to F (. C to C) Polycarbonate owl with Polyurethane owl Guard ()... to PSIG ( to. bar) F to F (. C to C) Zinc owl with Nylon Sight Gauge (W)... to PSIG ( to 7. bar) F to F (. C to 6.6 C) Weight luminum owl (E).... lb. (.9 kg) / Unit 7.8 lb. (.6 kg) / 8-Unit Master Pack luminum owl with Polycarbonate Sight Gauge (G) lb. (. kg) / Unit 7.6 lb. (. kg) / -Unit Master Pack Polycarbonate owl with Polyurethane owl Guard ().... lb. (. kg) / Unit. lb. (9. kg) / 8-Unit Master Pack Zinc owl with Nylon Sight Gauge (W).... lb. (. kg) / Unit 6. lb. (.97 kg) / 8-Unit Master Pack Materials of Construction ody... Zinc owls ()... Polycarbonate with Polyurethane Guard (E)... luminum (G)... luminum with Polycarbonate Sight Gauge (W)... Zinc with Nylon Sight Gauge Seals... una N

56 8 7 Catalog L66 Series Standard Lubricators / & Inch Ports L66 Standard Lubricators Features Metal owl with Sight Gauge - Standard Polycarbonate Sight ome F owl can be Filled while ir Line is Under Pressure 9 6 Proportional Oil elivery Over a Wide Range of ir Flows Large Capacity owl Optional High Capacity owl(s) vailable Precision Needle Valve ssures Repeatable Oil elivery and Provides Simple djustment of elivery Rate utomatic Fill Optional (Requires External Pressurized Oil Supply) High Flow: /" - 6 SCFM " - SCFM C E SCFM = Standard cubic feet per minute at PSIG inlet, and PSIG pressure drop. Port Size NPT SPP No rain No rain Zinc owl / Sight Gauge /" L66-6W L66G6W " L66-8W L66G8W luminum owl oz. without Sight Gauge /" L66-6E L66G6E " L66-8E L66G8E luminum owl 6 oz. with Sight Gauge /" L66-6G L66G6G " L66-8G L66G8G Standard part numbers shown bold. For other models refer to ordering information below. L66 Lubricator imensions C E F L66-6W, L66-8W (6) (8) (66.7) () () (6.) L66-6E, L66-8E (6) (7) (66.7) () () (6.) L66-6G, L66-8G (7) (9) (66) () () (6) inches (mm) Ordering Information L 66 6 W /** Port Threads NPT G SPP Port Size 6 / Inch 8 Inch owl owl Capacity escription Size E oz. Large Capacity /" & " without Sight Gauge G 6 oz. Large Capacity /" & " with Sight Gauge W 6 oz. Metal with /" & " Sight Gauge Options H utton Head Fill Fitting J utomatic Fill evice X9 Manual Twist rain (Increases Product Length by 9/6 Inch) Engineering Change esignator Will be entered at factory. NOTE: OL OPTIONS RE STNR.

57 8 7 Catalog (Revised //) Technical Specifications L66 L66 Series Standard Lubricators Technical Information Primary Pressure - bar Primary Pressure - PSIG F 9 C Pressure rop - bar... Pressure rop - PSIG F66-6W /-inch Port Flow - dm n /s E Primary Pressure - bar Primary Pressure - PSIG 7 L66-8G Pressure rop - bar... Pressure rop - PSIG F66-8W -inch Port Flow - dm n /s L66 Lubricator Kits & ccessories djusting Knob... 66Y7 owl Kits luminum (E)... K6 luminum with Sight Gauge (G)... K66X Zinc with Sight Gauge (W)... K69W utton Head Fill Fitting (9/6- male thread)... S66C9 ip Tube Kit... TK66 rip Spout Kit... RK66SY Mounting racket / Inch units ( required per unit)... SW7 Inch units ( required per unit)... SCW7 Repair Kits Needle Valve ssembly (ll)... RK66Y Sight Gauge owl Repair Kit (W)... RK6W Sight Gauge owl Repair Kit (G)... RK66X Specifications utomatic Fill Option (J) (Only available factory installed) Requires remote oil - PSIG above air pressure in bowl owl Capacity luminum (E)... Ounces luminum with Polycarbonate Sight Gauge (G)... 6 Ounces Zinc with Nylon Sight Gauge (W)... 6 Ounces Port Threads... /, Inch Pressure & Temperature Ratings luminum owl (E)... to PSIG ( to. bar) F to F (. C to 6.6 C) luminum owl with Polycarbonate Sight Gauge (G)... to PSIG ( to. bar) F to F (. C to C) Zinc owl with Nylon Sight Gauge (W)... to PSIG ( to 7. bar) F to F (. C to 6.6 C) Weight luminum owl (E).... lb. (.9 kg) / Unit. lb. (. kg) / -Unit Master Pack luminum owl with Polycarbonate Sight Gauge (G) lb. (.7 kg) / Unit 8.8 lb. (.6 kg) / -Unit Master Pack Zinc owl with Nylon Sight Gauge (W).... lb. (.9 kg) / Unit 6.6 lb. (7. kg) / -Unit Master Pack Materials of Construction ody... Zinc owls (E)... luminum (G)... luminum with Polycarbonate Sight Gauge (W)... Zinc with Nylon Sight Gauge Seals... una N

58 8 7 Catalog L66 Series Standard Lubricators -/ & -/ Inch Ports L66 Standard Lubricators Features Metal owl with Sight Gauge - Standard Polycarbonate Sight ome owl can be Filled while ir Line is Under Pressure Proportional Oil elivery Over a Wide Range of ir Flows Large Capacity owl Optional High Capacity owl(s) vailable Precision Needle Valve ssures Repeatable Oil elivery and Provides Simple djustment of elivery Rate utomatic Fill Optional (Requires External Pressurized Oil Supply) F 9 C E High Flow: -/" - SCFM -/" - SCFM SCFM = Standard cubic feet per minute at PSIG inlet, and PSIG pressure drop. Port Size NPT SPP No rain No rain Zinc owl / Sight Gauge -/" L66-W L66GW -/" L66-W L66GW luminum owl oz. without Sight Gauge -/" L66-E L66GE -/" L66-E L66GE luminum owl 6 oz. with Sight Gauge -/" L66-G L66GG -/" L66-G L66GG Standard part numbers shown bold. For other models refer to ordering information below. L66 Lubricator imensions C E F L66-W, L66-W (6) (9) (7.) () (66) (6.) L66-E, L66-E (6) (8) (7.) () () (6.) L66-G, L66-G (7) () (7.) () () (6) inches (mm) Ordering Information L 66 W /** Port Threads NPT G SPP Port Size -/ Inch -/ Inch owl owl Capacity escription Size E oz. Large Capacity -/" & -/" without Sight Gauge G 6 oz. Large Capacity -/" & -/" with Sight Gauge W 6 oz. Metal with -/" & -/" Sight Gauge Options H utton Head Fill Fitting J utomatic Fill evice X9 Manual Twist rain (Increases Product Length by 9/6 Inch) Engineering Change esignator Will be entered at factory. NOTE: OL OPTIONS RE STNR. 6

59 8 7 Catalog (Revised //) Technical Specifications L66 L66 Series Standard Lubricators Technical Information Primary Pressure - bar Primary Pressure - PSIG F 9 C Pressure rop - bar... Pressure rop - PSIG L66-W -/-inch Port Flow - dm n /s E Primary Pressure - bar Primary Pressure - PSIG 7 L66-G Pressure rop - bar... Pressure rop - PSIG L66-W -/-inch Port L66 Lubricator Kits & ccessories djusting Knob... 66Y7 owl Kits luminum (E)... K6 luminum with Sight Gauge (G)... K66X Zinc with Sight Gauge (W)... K69W utton Head Fill Fitting (9/6- male thread)... S66C9 ip Tube Kit... TK66 rip Spout Kit... RK66SY Repair Kits Needle Valve ssembly (ll)... RK66Y Sight Gauge owl Repair Kit (W)... RK6W Sight Gauge owl Repair Kit (G)... RK66X Specifications utomatic Fill Option (J) (Only available factory installed) Requires remote oil - PSIG above air pressure in bowl owl Capacity luminum (E)... Ounces luminum with Polycarbonate Sight Gauge (G)... 6 Ounces Zinc with Nylon Sight Gauge (W)... 6 Ounces Port Threads... -/, -/ Inch Flow - dm n /s Pressure & Temperature Ratings luminum owl (E)... to PSIG ( to. bar) F to F (. C to 6.6 C) luminum owl with Polycarbonate Sight Gauge (G)... to PSIG ( to. bar) F to F (. C to C) Zinc owl with Nylon Sight Gauge (W)... to PSIG ( to 7. bar) F to F (. C to 6.6 C) Weight luminum owl (E) lb. (.76 kg) / Unit. lb. (.6 kg) / -Unit Master Pack luminum owl with Polycarbonate Sight Gauge (G)... lb. (. kg) / Unit lb. (8. kg) / -Unit Master Pack Zinc owl with Nylon Sight Gauge (W) lb. (. kg) / Unit 8. lb. (.79 kg) / -Unit Master Pack Materials of Construction ody... Zinc owls (E)... luminum (G)... luminum with Polycarbonate Sight Gauge (W)... Zinc with Nylon Sight Gauge Seals... una N 7

60 PRESS TURN Catalog Hi-Flow 9L Series Hi-Flow Mist Lubricators Inch Ports 9L Mist Lubricators Hi-Flow Features Metal owl with Sight Gauge and Manual rain Standard F Polycarbonate Sight ome for 6 Visibility owl can be Filled while ir Line is Under Pressure Proportional Oil elivery Over a Wide Range Of ir Flows High Flow: SCFM C C E E Port Size NPT Metal owl / Sight Gauge Quart " 9L8 Metal owl / Sight Gauge Quart " 9L8P Standard part numbers shown bold. For other models refer to ordering information below. SCFM = Standard cubic feet per minute at 9 PSIG inlet and PSIG pressure drop. 9L Lubricator imensions C E F Qt () (6) (67) () C E Qt () () (67) () (7) (8) Inches (mm) Ordering Information 9L 8 Engineering Port Port Size owl Options Options Level Type 8. Inch Metal owl. Quart Sight Gauge / Manual Twist rain P. Quart Sight Gauge / Manual Twist rain. Without Tamperproof Cap. Current lank. NPT NOTE: OL OPTIONS RE STNR. 8

61 Catalog Technical Specifications 9L 9L Series Mist Lubricators Technical Information Primary Pressure - bar Primary Pressure - PSIG 6 9 Pressure rop - bar... Pressure rop - PSIG 9L8P Inch Ports Flow - dm /s n 9L Lubricator Kits & ccessories Fill Cap Kit... PS6P Lubricator Service Kit... PS67P Metal owl Sight Gauge / Twist rain... PS6P* Oil Gal.... F Quart Case... F Gallon Case... F Sight ome Kit... PS6P * Quart owl Specifications owl Capacity... Qt. (Standard) Qt. (Optional) owl... Metal with Sight Gauge rain... Manual Twist rain Port Threads... Inch Pressure & Temperature Rating... to PSIG ( to. bar) F to F ( C to 66 C) Suggested Lubricant... F Oil Petroleum based oil of to SSU viscosity at F and an aniline point greater than F (O NOT USE OILS WITH ITIVES, COMPOUNE OILS CONTINING SOLVENTS, GRPHITE, ETERGENTS, OR SYNTHETIC OILS.) Weight Qt.... lb. (.6 kg) Qt....7 lb. (6. kg) Materials of Construction ody... Zinc lloy, ie Cast 9

62 E N T Catalog (Revised //) / Series General Purpose Filter / Regulators /", /8", /" Ports / General Purpose Filter / Regulators Features High Flow Performance iaphragm Operated esign Excellent Water Removal Efficiency Metal owl with Sight Gauge, Twist rain and Micron Element Standard Panel Mountable High Flow: /" - 7 SCFM /8" - 7 SCFM /" - 8 SCFM : Push-to-Lock, Pull-to-djust. djusting Lock is engaged when Knob is Removed Rendering Unit Tamper Resistant : Heavy uty Tee Handle djustment SCFM = Standard cubic feet per minute at PSIG inlet, 7 PSIG no flow secondary setting, and PSIG pressure drop. NOTE:.7 ia. (mm) hole required for panel mounting. N C E P - P T U L L C L O + K N C E Port Size NPT NPT Manual Manual Twist rain uto rain Twist rain uto rain Zinc owl / Sight Gauge /" -WJC -WJCR -WJC -WJCR /8" -WJC -WJCR -WJC -WJCR /" -WJC -WJCR -WJC -WJCR Standard part numbers shown bold. For other models refer to ordering information below. / Integral Filter / Regulator imensions C E N (9) (6) (86.) (6) () (.8) (9) (6) (9) (6) (9) (.8) inches (mm)! WRNING o not connect regulator to bottled gas. o not exceed maximum primary pressure rating. Product rupture can cause serious injury. Ordering Information W J C /** Series Tamper Resistant, Snap Lock, Removable Knob T-handle CUTION: Port Threads NPT G SPP Port Size / Inch /8 Inch / Inch owl Metal without Sight Gauge W Metal with Sight Gauge REGULTOR PRESSURE JUSTMENT The working range of knob adjustment is designed to permit outlet pressures within their full range. Pressure adjustment beyond this range is also possible because the knob is not a limiting device. This is a common characteristic of most industrial regulators, and limiting devices may be obtained only by special design. NOTE: OL OPTIONS RE STNR. 6 Elements G Micron J Micron Reduced Pressure Range - PSIG -6 PSIG C - PSIG - PSIG Options G Gauge K Non-Relieving R Internal uto rain S utomatic Pulse rain X6 Fluorocarbon O-Rings and iaphragm Engineering Change esignator Will be entered at factory.

63 Catalog (Revised //) Technical Specifications / / Series General Purpose Filter / Regulators Technical Information Secondary Pressure - bar 6 Secondary Pressure - PSIG 7 -J /-inch Ports PSIG (6.9 bar) Primary Pressure 6 8 Rated Secondary Pressure - bar 6 Secondary Pressure - PSIG 7 / / & /8 Inch Ports PSIG (6.9 bar) Primary Pressure 6 8 Rated 6 Flow - dm n /s 6 Flow - dm n /s / Integral Filter / Regulator Kits & ccessories owl Kits Zinc ()... KFY Zinc with Sight Gauge (W)...KFWY Cage Kits... CKRY... CKRY rain Kits Internal uto rain (Max. Press. = 7 PSIG; Max. Temp. = F)... S6M utomatic Pulse rain (Maximum Pressure = 7 PSIG)... Filter Element Kits Micron (ll)... EKFY Micron (ll)... EKFVY Gauges " ial Size, /" ack Connection to 6 PSIG ( to kpa)... 7Y6S " ial Size, /" ack Connection to 6 PSIG ( to kpa)... 7Y6S " ial Size, /" ack Connection to PSIG ( to 68 kpa)... 7YS Mounting racket Kit... SRY7 Panel Mount Nut Plastic... RX-P luminum... RX- Repair Kits Non-Relieving iaphragm, Valve ssembly* (ll)... RKRKY Relieving iaphragm, Valve ssembly* (ll)... RKRY Internal uto rain Repair Kit... RK6M Specifications owl Capacity... Ounces Gauge Ports ()... / Inch Port Threads... /, /8, / Inch Supply Pressure Zinc owl ()... PSIG Maximum (. bar) Zinc owl with Sight Gauge (W)... PSIG Maximum (7. bar) with uto rain... 7 PSIG Maximum (. bar) Temperature Rating Zinc owl... F to F (. C to 6.6 C) Zinc owl with uto rain... F to F (. C to C) Weight.... lb. (.9 kg) / Unit. lb. (.6 kg) / 8-Unit Master Pack Materials of Construction djusting Knob... cetal (Tee Handle)... Steel ody... Zinc owls Without Sight Gauge... Zinc With Nylon Sight Gauge... Zinc Seals... una N * Specify same model / revision number for repair kit as for filter/regulator. For example, -JC/M uses RKRYM. 6

64 7 6 9 Catalog Model Numbers and imensions C / C Series Standard Combinations Standard Combinations C & C Series See individual component pages for details. Gauges included on combinations. Two & Three-Unit Combo 76 9 C F E F C E Filter / Regulator Filter, Regulator Series Port with Lubricator Lubricator /" C-LWJCW C-FRLWJCW C /8" C-LWJCW C-FRLWJCW /" C-LWJCW C-FRLWJCW /" C-LWJCW C-FRLWJCW C /8" C-LWJCW C-FRLWJCW /" C-LWJCW C-FRLWJCW For other models, refer to ordering information below. C E F C-L, C-L, C-L (77) () (86) (68) (9) (8) C-FRL, C-FRL, C-FRL (78) () (6) (68) () (8) Inches (mm) ll dimensions nominal. Ordering Information C FRL W J C W Regulator djustment Knob Tee Handle Port Size / Inch /8 Inch / Inch Combination L -Unit FRL -Unit Filter owl Options owl escription Polycarbonate / Plastic owl Guard (Filter Only) Metal wo/sight Gauge (-Unit Only) W Metal w/sight Gauge CUTION: REGULTOR PRESSURE JUSTMENT The working range of knob adjustment is designed to permit outlet pressures within their full range. Pressure adjustment beyond this range is also possible because the knob is not a limiting device. This is a common characteristic of most industrial regulators, and limiting devices may be obtained only by special design. NOTE: OL OPTIONS RE STNR. Elements G Micron J Micron Regulator Reduced Pressure Range C - PSIG - PSIG owl W rains and Options H utton Head Fill Fitting (Lubricator) K Non-Relieving Regulator R Internal uto rain (Filter) X9 Manual Twist rain on Lubricator (Increases Product Length by 9/6 Inch) Lubricator owl Options escription Polycarbonate / Plastic owl Guard Metal w/sight Gauge 6

65 7 6 9 Catalog Model Numbers and imensions C68 Series Standard Combinations Standard Combinations C68 Series See individual component pages for details. Gauges included on combinations. Three-Unit Combo F C E C68-FRLWJCW Shown Series Port Model Numbers /" C68-FRLWJCW /8" C68-FRLWJCW /" C68-FRLWJCW C68 /" C68-6FRLWJCW " C68-8FRLWJCW -/" C68-FRLWJCW -/" C68-FRLWJCW For other models, refer to ordering information below. C E F C68-FRL, C68-FRL () (7) (7) (67) (9) (8) C68-FRL (7) (6) (6) (7) (6) (8) C68-6FRL, C68-8FRL () (97) () (89) () (6) C68-FRL, C68-FRL (9) (6) () (98) (9) (67) Inches (mm) ll dimensions nominal. Ordering Information C 68 FRL W J C W Port Size Filter owl Options Elements rains and Options / Inch /8 Inch / Inch 6 / Inch 8 Inch -/ Inch -/ Inch owl Capacity escription Size oz. Polycarbonate w/plastic owl Guard /" & /8" 8 oz. Polycarbonate w/plastic owl Guard /" E 6 oz. Large Capacity wo/sight Gauge /" E oz. Large Capacity wo/sight Gauge /" thru -/" W oz. Metal w/sight Gauge /" & /8" W 8 oz. Metal w/sight Gauge /" W 6 oz. Metal w/sight Gauge /" thru -/" G J Micron Micron Regulator Reduced Pressure Range C - PSIG - PSIG H utton Head Fill Fitting (Lubricator) K Non-Relieving Regulator Q External Heavy uty uto rain (Filter) R Internal uto rain (Filter) X9 Manual Twist rain on Lubricator (Increases Product Length by 9/6 Inch) CUTION: REGULTOR PRESSURE JUSTMENT The working range of knob adjustment is designed to permit outlet pressures within their full range. Pressure adjustment beyond this range is also possible because the knob is not a limiting device. This is a common characteristic of most industrial regulators, and limiting devices may be obtained only by special design. NOTE: OL OPTIONS RE STNR. Lubricator owl Options owl Capacity escription Size oz. Polycarbonate w/plastic owl Guard /" & /8" 8 oz. Polycarbonate w/plastic owl Guard /" E 6 oz. Large Capacity wo/sight Gauge /" E oz. Large Capacity wo/sight Gauge /" thru -/" W oz. Metal w/sight Gauge /" & /8" W 8 oz. Metal w/sight Gauge /" W 6 oz. Metal w/sight Gauge /" thru -/" 6

66 Catalog General Information Compressed ir Treatment QIX Modular FRL System QIX Modular FRL System QIX is the Premium FRL System for the emanding, High Performance Manufacturer ddressing the needs of the production-oriented plant more than a decade ago, WTTS Fluidir pioneered a break through in FRL technology. The QIX Series of high flow, generously sized filters, regulators lubricators and accessories. esigned around the parameters of one inch pipe, every QIX component is manufactured with wide open internal porting for maximum efficiency and optimum performance at flow rates up to SCFM. QIX Means Less owntime Qix is short for Quick Insert exchange. y means of removable connector -inserts, any QIX unit easily adapts to a variety of pipe sizes ranging from " down to /". Each time you change pipe size or units, you change only the insert - not the filter, regulator, or lubricator. Pull two pins with a pair of pliers and your change is made in seconds. QIX Means Less Inventory Plus Simplified Specification, Ordering and Service The QIX concept enables you to stock one basic size filter, regulator or lubricator module along with an assortment of economical insert kits. You save as much as % on inventory. Working with fewer part numbers, you simplify engineering specs, lessen purchasing efforts and improve overall service. Inserts ll QIX components connect using inserts, o-rings and pins. Pins are easily removed using standard pliers. No special tools are required. Threaded end inserts, /" through ", make it easy to replace a complete FRL in seconds without breaking pipe connections. lso allows you to stock only one FRL for all your /" through " plant needs. Shut-Off Valves (IKV) Isolate downstream equipment with three-way lockable shutoff valve, Complies with OSH Standard 9 CFR Part 9. Vented to relieve downstream pressure in off position. utomatic Float rain Optional automatic float drain removes condensate as required. Manual drain is standard. Pressure Switch Low cost miniature pressure switch easily integrates into your QIX system via a porting block. The switch provides an electric signal when set pressure is achieved. Porting lock Insert style porting blocks are available with /" NPT branch lines. They allow the mounting of a pressure switch or branching off a non-lubricated line. urable Textured Finish ll QIX components are powder coated to ensure a hard, durable finish. Particulate Filters (F) eflector plate insures maximum water removal while micron element eliminates damaging particulate mater. Oil-removing coalescing filters (F) are also available. One-piece rugged metal bowls with sight gauge and bright liquid level indicating float are standard on all filters and lubricators. Regulators (R) ccurate high-flow regulators are equipped with positive snap lock, push / pull adjusting knobs for easy operation. ayonet style spring cage is removed with only the push of a button. Piston and o-ring is replaceable in seconds, using standard pliers. Lubricators (L) ypass valve system provides consistent lubrication under variable flow conditions. Removable adjusting knob renders the lubricator tamperproof (standard). QIX lubricators are fillable under pressure. 6

67 Catalog General Information Compressed ir Treatment QIX Modular FRL System QIX Modular FRL System Quick Insert Xchange Inserts O-rings Pressure Switch Shut-Off Valves Porting lock Lubricators Particulate Filters Pressure Gauges utomatic Float rain Regulators 6

68 Catalog F, F Series QIX Filters /, /8, /, / & Inch Ports F & F QIX Particulate & Coalescing Filters Manual rain utomatic rain Features Unique Interchangeable QIX Inserts llow One Module to ccommodate Port Sizes /", /8" /", /", " F For Heavy uty pplications with Minimum Pressure rop Requirement Excellent Water Removal Efficiency vailable in oth Particulate (F) and Coalescing (F) Configurations C Metal owl with Sightgauge Standard Manual rain Standard. utomatic Float rain Optional High Flow - 8 SCFM for /" & " Sizes (F) SCFM (F Coalescing) E F & F Filter imensions C * ** E F (7) (7) (9) (89) () (9) () inches (mm) * / thru / Inch Port Insert Size ** Inch Port Insert Size Ordering Information F W J /** Port Threads Port Size Elements rains and Options Engineering Change esignator NPT G* SPP * If ordering SPP Port Inserts Separately - Order - Unit No Port Inserts / Inch /8 Inch / Inch 6 / Inch 8 Inch J F Micron G F Micron J* F. Micron Coalescing * Only vailable with F R Internal uto Float rain S utomatic Pulse rain Will be entered at factory. NOTE: OL OPTIONS RE STNR. 66

69 Catalog (Revised //) Technical Specifications F, F QIX Series Particulate & Coalescing Filters Technical Information Pressure rop - bar... Pressure rop - PSIG F Flow Chart /" /8" /" /" & " F Standard Micron Filter Flow - dm /s n F Flow: PSIG QIX F & F Kits & ccessories utomatic Float rain... S6M utomatic Pulse rain... owl Kit... KFW owl Sightgauge Repair Kit... RK6W Combination Connector... IKCC (Connects QIX units together) Combination Porting lock... IKCP (same as IKCC, except with /8" top branch outlet) Element Kits Particulate (F) micron...ekf Particulate (F) micron... EKFV Coalescing (F). micron... EKF6J Mounting brackets (pair)... MK- (Mounts directly to port inserts) Port Insert Kits (includes o-rings & pins) NPT /" Port Size... IKY /8" Port Size... IKX /" Port Size... IK /" Port Size... IK " Port Size... IKC Shut-off Valve w/lockout (for inlet)... IKV Specifications owl Capacity... oz. Filter Element Rating J (F particulate)... micron G (F particulate)... Micron J (F coalescing).... Micron Maximum Pressure... PSIG With utodrain... 7 PSIG Port Threads / Inserts... No Port Inserts... /"... /8"... /" 6... /" 8... " Temperature Range... F to F (. C to 6.6 C) With uto rain... F to F (. C to C) Weight.... lb (For total weight add. lb for port inserts) Materials of Construction ody... Zinc owl... Zinc rain... rass Filter Element Particulate... Polypropylene Coalescing... orosilicate Fibers Thread Inserts... Zinc Seals... una-n Sightgauge... Nylon 67

70 6 9 Catalog R, R Series QIX Regulators, / & Inch Ports R & R QIX Regulators Features Unique Interchangeable QIX Inserts llow One Module to ccommodate Port Sizes /", /8" /", /", " Piston Operated for High Flow Performance Secondary spiration Plus alanced Poppet Provides Quick Response and ccurate Pressure Regulation Panel Mountable High Flow: SCFM for /" & " Port Sizes R Features Push-to-Lock, Pull-to-djust, Remove-for- Tamper-Resistant Knob Feature R Features Heavy uty Tee Handle djustment PT E NT P - + U L L L 7 K O C C E R Regulator imensions C * ** E (77) (86) (9) (89) () () R Regulator imensions C * ** E..7.. (77) (86) () (89) () () inches (mm) * / thru / Inch Port Insert Size ** Inch Port Insert Size Ordering Information R C /** djustment Type Knob Tee-Handle CUTION: Port Threads NPT G* SPP * If ordering SPP Port Inserts Separately - Order G Unit Port Size No Port Inserts / Inch /8 Inch / Inch 6 / Inch 8 Inch Reduced Pressure -6 PSIG C - PSIG - PSIG REGULTOR PRESSURE JUSTMENT The working range of knob adjustment is designed to permit outlet pressures within their full range. Pressure adjustment beyond this range is also possible because the knob is not a limiting device. This is a common characteristic of most industrial regulators, and limiting devices may be obtained only by special design. NOTE: OL OPTIONS RE STNR. Options P Panel Mount Nut (Plastic) G Gauge K Non-Relieving Engineering Change esignator Will be entered at factory. 68

71 Catalog (Revised //) Technical Specifications R, R QIX Series Regulators Technical Information R / R Supply Pressure PSI Secondary Pressure - bar Secondary Pressure - PSIG 7 /" /" /" /8" /8" /8 /" /" /" /" & " /" & " /" & " Flow - dm n /s QIX R & R Kits & ccessories Combination Connector... IKCC (Connects QIX units together) Combination Porting lock... IKCP (same as IKCC, except with /8" top branch outlet) Mounting brackets (pair)... MK- (Mounts directly to port inserts) Wall Mounting racket... SR7 (Uses panel mount threads - includes plastic panel mount nut) Panel Mount Nut Plastic... RX-P luminum... RX- Port Insert Kits (includes o-rings & pins) NPT /" Port Size... IKY /8" Port Size... IKX /" Port Size... IK /" Port Size... IK " Port Size... IKC Repair Kit - Internal Parts (Piston, Innervalve, Seals) Relieving... RKR Non-Relieving (K)... RKRK Spring Cage Kit R... CKR R... CKRY Shut-off Valve w/lockout (for inlet)... IKV 69 Specifications Gauge Ports... () /" Maximum Pressure... PSIG Port Threads / Inserts... No Port Inserts... /"... /8"... /" 6... /" 8... " Reduced Pressure Range PSIG C... - PSIG... - PSIG Temperature Range... F to F Weight....6 lb (For total weight add. lb for port inserts) Materials of Construction djusting Knob... (R/ ) cetal djusting Screw (all)... Steel ody... Zinc ottom Plug... rass Innervalve... rass Piston... Nylon Seals... una-n Spring Cage... Zinc Springs... Steel Thread Inserts... Zinc

72 Catalog L Series QIX Lubricators /, /8, /, / & Inch Ports L QIX Lubricators Features Unique Interchangeable QIX Inserts llow One Module to ccommodate Port Sizes /", /8" /", /", " High Flow Venturi and y-pass Valve to Minimize Pressure rop and Ensure Consistant Lubrication at ll Rated Flows Excellent Water Removal Efficiency F C Tamper Resistant Removable rip Control Knob Manual rain Standard High Flow: SCFM for /" & " Port Sizes E L Filter imensions C * ** E F (8) (7) () (89) () (8) () inches (mm) * / thru / Inch Port Insert Size ** Inch Port Insert Size Ordering Information L W /** Port Threads Port Size Options Engineering Change esignator NPT G* SPP * If ordering SPP Port Inserts Separately - Order - Unit No Port Inserts / Inch /8 Inch / Inch 6 / Inch H utton Head Fill Fitting Will be entered at factory. 8 Inch NOTE: OL OPTIONS RE STNR. 7

73 Catalog Technical Specifications L QIX Series Lubricators Technical Information /" /8" /" / & "" Pressure rop - bar... Pressure rop - PSIG L Supply Pressure PSIG 6 8 Flow - dm n /s QIX L Kits & ccessories owl Kit... KFW owl Sightgauge Repair Kit... RK6W utton Head Fill Fitting... S66C9 (9/6- male thread) Combination Connector... IKCC (Connects QIX units together) rip Control Repair Kit... RKL Internal y-pass Repair Kit... RKL Mounting rackets (pair)... MK- Port Insert Kits (includes o-rings & pins) NPT /" Port Size... IKY /8" Port Size... IKX /" Port Size... IK /" Port Size... IK " Port Size... IKC Shut-off Valve w/lockout (for inlet)... IKV Specifications owl Capacity... oz. Maximum Pressure... PSIG Port Threads / Inserts... No Port Inserts... /"... /8"... /" 6... /" 8... " Temperature Range... F to F Weight.... lb (For total weight add. lb for port inserts) Materials of Construction ody... Zinc owl... Zinc rain... rass rip Control... Polyurethane Seals... una-n Sightgauge... Nylon Thread Inserts... Zinc 7

74 6 9 Catalog & Series QIX Filter / Regulators /, /8, /, / & Inch Ports & QIX Filter / Regulators Features PT E Unique Interchangeable QIX Inserts llow One Module to ccommodate Port Sizes /", /8" /", /", " Piston Operated Regulator for High Flow Performance Excellent Water Removal Efficiency Secondary spiration Plus alanced Poppet Provides Quick Response and ccurate Pressure Regulatorion Excellent Water Removal Efficiency Manual rain Standard utomatic rain Optional Panel Mountable High Flow: SCFM for /" & " Port Sizes Features Push-to-Lock, Pull-to-djust, Remove-for-Tamper Resistant Knob Feature Features Heavy uty Tee Handle djustment Filter / Regulator imensions C * ** E (77) (7) () (89) () (86) Filter / Regulator imensions C * ** E (77) (86) () (89) () () inches (mm) * / thru / Inch Port Insert Size ** Inch Port Insert Size NT P U L L L K O C C E Ordering Information W J C /** djustment Type Knob Tee Handle CUTION: Port Threads NPT G* SPP * If ordering SPP Port Inserts Separately - Order G Unit Port Size No Port Inserts / Inch /8 Inch / Inch 6 / Inch 8 Inch Elements G Micron J Micron Reduced Pressure Range -6 PSIG C - PSIG - PSIG rains and Options G Gauge K Non-Relieving P Panel Mount Nut (Plastic) R Internal uto Float rain S utomatic Pulse rain Engineering Change esignator Will be entered at factory. REGULTOR PRESSURE JUSTMENT The working range of knob adjustment is designed to permit outlet pressures within their full range. Pressure adjustment beyond this range is also possible because the knob is not a limiting device. This is a common characteristic of most industrial regulators, and limiting devices may be obtained only by special design. NOTE: OL OPTIONS RE STNR. 7

75 Catalog (Revised //) Technical Specifications & QIX Series Filter / Regulators Technical Information 8 / Supply Pressure PSIG / & " Pressure rop - bar... Pressure rop - PSIG 6 /" /" /8" /8" /" /8" /" / & " /" /" / & " 6 8 Flow - dm n /s QIX L Kits & ccessories utomatic Float rain... S6M utomatic Pulse rain... owl Kit... KFW owl Sightgauge Repair Kit... RK6W Combination Connector... IKCC (Connects QIX units together) Combination Porting lock... IKCP (same as IKCC, except with /8" top branch outlet) Element Kits Particulate (F) micron... EKF Particulate (F)... micron EKFV Mounting rackets (pair)... MK- Panel Mount Nut Plastic... RX-P luminum... RX- Port Insert Kits (includes o-rings & pins) NPT /" Port Size... IKY /8" Port Size... IKX /" Port Size... IK /" Port Size... IK " Port Size... IKC Repair kit - internal parts (piston, innervalve, seals) Relieving... RKR Non-Relieving (K)... RKRK Spring Cage Kit R... CKR R... CKRY Wall Mounting racket... SR 7 (uses panel mount threads - includes plastic panel mount nut) Specifications owl Capacity... oz. Filter Element Rating J (particulate)... micron G (particulate)... Micron 7 Gauge Ports ()... /" Maximum Pressure... PSIG With uto rain... 7 PSIG Port Threads / Inserts... No Port Inserts... /"... /8"... /" 6... /" 8... " Reduced Pressure Range PSIG C... - PSIG... - PSIG Temperature Range... F to F (. C to 6.6 C) With uto rain... F to F (. C to C) Weight.... lb (For total weight add. lb for port inserts) Materials of Construction djusting Knob (R/ )... cetal djusting Screw (all)... Steel ody... Zinc ottom Plug... rass owl... Zinc rain... rass Filter Element (particulate)... Polypropylene Innervalve... rass Piston... Nylon Seals... una-n Sightgauge... Nylon Spring Cage... Zinc Springs... Steel Thread Inserts... Zinc

76 8 6 psi psi 6 Catalog Model Numbers and imensions QIX Series Two & Three Unit Combinations QIX Combinations C / C Series See individual component pages for details. Gauges included on combinations. Three-Unit Combo F F G G G G G G C C E E C-FRL imensions C * ** () (7) () (69) (7) (8) E F G G G (9) (6) () (6) (9) (6) C-L imensions C * ** () (7) () (86) (88) (9) E F G G G (86) () (6) (9) (6) inches (mm) * / thru / Inch Port Insert Size ** Inch Port Insert Size Ordering Information C FRL L W J C W /** djustment Type Knob Tee Handle Port Threads NPT G* SPP * If ordering SPP Port Inserts Separately - Order G Unit CUTION: REGULTOR PRESSURE JUSTMENT The working range of knob adjustment is designed to permit outlet pressures within their full range. Pressure adjustment beyond this range is also possible because the knob is not a limiting device. This is a common characteristic of most industrial regulators, and limiting devices may be obtained only by special design. NOTE: OL OPTIONS RE STNR. Port Size / Inch /8 Inch / Inch 6 / Inch 8 Inch Combination L -Unit FRL -Unit Elements G Micron J Micron Regulator Reduced Pressure Range -6 PSIG C - PSIG - PSIG rains and Options K Non-Relieving R Internal uto Float rain S utomatic Pulse rain Engineering Change esignator Will be entered at factory. 7

77 Catalog (Revised //) Features & Ordering Information QIX Series ccessories QIX ccessories QIX Port Insert Kits & ccessories Port Insert Kits (includes o-rings & pins) NPT SPP Port Size NPT SPP /" IKY IKYG /8" IKX IKXG /" IK IKG /" IK IKG " IKC IKCG Combination IKCC IKCC Connector (connects QIX units together) Combination IKCP IKGCP Porting lock (same as IKCC, except with /" top branch outlet) IKCP PST Porting lock and 98 Pressure Switch Insert O-ring QIX IKV Shut-Off Valve This modular, -way ball valve attaches between the port insert and the inlet side of any QIX component. This valve shuts off the air pressure and vents the downstream pressure through a /8" NPTF port in the bottom of the valve. The valve comes standard with a lockout feature as required by OSH Standard 9.7 Valve adds." to width of system. Pressure Switch P98 Green Red (Normally Closed) (Normally Open) Ø. (8) lack (Common) Pin.8 (.).8 (.8) /" NPT QIX MK Mounting rackets Part Number: MK- Kit contains brackets and screws Port Insert ssembly.6 (6).8 (6).69 () Features: Inline Mounting amp Rated Snap ction Micro Switch rass ody Compact Size Flying Leads Electrical Connection Specifications IP6 Rated Field djustable - PSIG +/- % Repeatability Single Pole / ouble Throw Switch Electrical... MP, /VC, /VC Maximum Inlet Pressure... PSIG ( bar) Mechanical Life... x 6 at 7 PSIG ( bar) Electrical Connection... 8" Flying Leads Electrical Protection... IP6 Pressure ifferential ead and to PSIG (. to.9 bar) Repeatability... ±% at 7 F ( C) mbient Temperature Range... - F to 8 F (- C to 8 C) Weight.... lb. (. Kg) Materials of Construction iaphragm... Nitrile Housing... rass 7

78 Catalog 7 Series (Revised //) ccessories In-Line ronze Filters Inline ronze Filters C Features 7 ll ronze Unit esigned for pplications where Fine Straining of ir is Required Porous ronze Element Strains Out Particles Larger than 9 Microns (. Inch) C 7 9 Micron Element* With Manual Port Size No rain Petcock rain /" 7-7- /8" 7-7- /" 7-7- * dd V Suffix for Micron Element. In-Line ronze Filters C With No rain (66.7) (6) (.7) (9.) With Manual Twist rain (66.7) (8) (6.8) (9.) inches (mm) Replacement Elements Micron... 7Y77-9 Micron... RK7Y Specifications Maximum Pressure... PSIG Performance Pressure rop (PSIG) at Various Conditions Flow Supply Pressure PSIG Supply Pressure PSIG Weight /" & /8"....9 lb. (. kg) / Unit lb. (9.96 kg) / 8-Unit Master Pack /".... lb. (.9 kg) / Unit lb. (.9 kg) / 8-Unit Master Pack 76 Materials of Construction ody... ronze Element Standard... 9 Micron Porous ronze Optional... Micron Porous ronze Seals... una N

79 Catalog (Revised //) Features and imensions ccessories Tank rains - Tank rain Features Metal owl without Sight Glass Port Size / Inch NPTF ody Zinc owl Zinc. (9). () ia. Minimum Supply Pressure PSIG Maximum Supply Pressure 7 PSIG Max. Operating Temperature F ( C) Seals una-n owl Capacity oz. Weight per Unit lb. Master Pack Quantity Master Pack Weight lbs..7 () -W Tank rain Features Metal owl with Sight Glass ody Zinc. (9). () ia. Port Size / Inch NPTF owl Zinc Minimum Supply Pressure PSIG Maximum Supply Pressure 7 PSIG Max. Operating Temperature F ( C) Seals una-n owl Capacity oz. Weight per Unit lb. Master Pack Quantity Master Pack Weight lbs.. (6).7 () 68- Tank rain Features Polycarbonate owl with Polyethylene owl Guard Port Size / Inch NPTF Minimum Supply Pressure PSIG Maximum Supply Pressure PSIG Max. Operating Temperature F ( C) ody luminum owl Polycarbonate Seals una-n owl Capacity 8 oz. Weight per Unit lb. Master Pack Quantity 8 Master Pack Weight 7 lbs. UTO-RIN.76 (96) 7.7 (97) 68-W Tank rain Features Metal owl with Sight Glass ody luminum.76 (96) Port Size / Inch NPTF owl Zinc Minimum Supply Pressure PSIG Maximum Supply Pressure PSIG Max. Operating Temperature F ( C) Seals una-n owl Capacity 8 oz. Weight per Unit lb. Master Pack Quantity 8 Master Pack Weight 7 lbs. UTO-RIN 7.8 (99) 77

F20 & F21 QIX Particulate & Coalescing Filters

F20 & F21 QIX Particulate & Coalescing Filters F2, F21 Series QIX Filters 1/4, 3/8, 1/2, 3/4 & 1 Inch Ports F2 & F21 QIX Particulate & oalescing Filters Manual rain utomatic rain Unique Interchangeable QIX Inserts llow One Module to ccommodate Port

More information

PDE2611TCUK-ca Air Preparation. Miniature FRL series. Miniature FRL Series. Parker Hannifin Corporation Pneumatic Division - Europe

PDE2611TCUK-ca Air Preparation. Miniature FRL series. Miniature FRL Series. Parker Hannifin Corporation Pneumatic Division - Europe P26TUK-ca ir Preparation Miniature RL series Miniature RL Series 49 Parker Hannifin orporation Pneumatic ivision - urope P26TUK-ca ir Preparation Miniature RL series - /8", /4" asic /8" ody 4 ilters -

More information

Stainless Steel FRLs

Stainless Steel FRLs Stainless steel FRLs Stainless Steel FRLs Units 205 Stainless steel FRLs - PF504 Series - 1/4 Inch Ports PF504 Filter Miniature Features Stainless steel construction handles most corrosive environments

More information

FRL/AirCare Air Controls & Accessories

FRL/AirCare Air Controls & Accessories FRL/irare ir ontrols & ccessories Lincoln Regulators, Filters & Lubricators well-planned compressed air system ensures minimum pressure loss in the system, and the removal of contaminants: water, compressor

More information

IC3A, IC3D, IC4A and IC4D ISO Spirax-Monnier International Ultraclean Compressed Air Filters

IC3A, IC3D, IC4A and IC4D ISO Spirax-Monnier International Ultraclean Compressed Air Filters Page 1 of 5 ert. No. LRQ 0963008 Manual rain TI-P501-01 H Issue 5 I3, I3, I4 and I4 ISO 9001 Spirax-Monnier International Ultraclean ompressed ir Filters uto rain International Symbol escription The Spirax-Monnier

More information

Model Model 815

Model Model 815 Model 600004 Model 600204 Model 85387 Model 600104 Model 815 ir line products and accessories ir couplers and nipples............................... 196 low guns, tire inflators and siphon sprayers.............

More information

Air Line Modulars Each component is engineered to connect easily modular FRL assemblies manual shut off

Air Line Modulars Each component is engineered to connect easily modular FRL assemblies manual shut off Air Line Modulars Each component is engineered to connect easily without the use of inserts and special tools. Standard buttonhead screws are used to join components, combined with the new modular design

More information

AIR PREPARATION PRODUCTS. Table of Contents

AIR PREPARATION PRODUCTS. Table of Contents AIR PREPARATION PRODUCTS Table of Contents Page Air Filters................................................. 5-7 Oil Removal Filters......................................... 8-9 Regulators..............................................

More information

Parker Global Air Preparation System

Parker Global Air Preparation System Parker Global System Parker Global System A complete air preparation system 7 Parker Global System Parker Global Air Preparation System Global. Economical. Modular. Performance you need, wherever you need

More information

VALVES. Wilkerson. Filters, Regulators & Lubricators. dixonvalve.com Customer Service:

VALVES. Wilkerson. Filters, Regulators & Lubricators. dixonvalve.com Customer Service: FACTURING QUALITY SERVICE MANUFACTURING QUALITY SERVICE MANUFACTURING QUALITY SERVICE MANUFACTURI VALVES Wilkerson Filters, Regulators & Lubricators dixonvalve.com Customer Service: 877.963.4966 Filters

More information

MIS SERIES. Mist Eliminator. Installed differential pressure gauge and optional zero air-loss drain valve. Air or Water Cooled Aftercooler

MIS SERIES. Mist Eliminator. Installed differential pressure gauge and optional zero air-loss drain valve. Air or Water Cooled Aftercooler MIS SERIES Mist Eliminator The ircel MIS Mist Eliminator (300-8000 scfm) provides a full line of mist eliminators to effectively remove oil, solids and water from your compressed air system. In addition,

More information

Pneumatic. Prep-Air II 05 Series Air Preparation Units Filter, Regulator, Lubricator, and Modular Accessories Catalog 0708/USA

Pneumatic. Prep-Air II 05 Series Air Preparation Units Filter, Regulator, Lubricator, and Modular Accessories Catalog 0708/USA Prep-ir II 5 Series ir Preparation Units Filter, Regulator, Lubricator, and Modular ccessories atalog 78/US WRNING FILUR OR IMPROPR SLTION OR IMPROPR US OF TH PROUTS N/OR SYSTMS SRI HRIN OR RLT ITMS N

More information

50 SERIES FILTER F50B Series F50B-04 pictured Application ANSI SYMBOL Primary air filters are designed to separate liquid, water, rust, pipe scale, an

50 SERIES FILTER F50B Series F50B-04 pictured Application ANSI SYMBOL Primary air filters are designed to separate liquid, water, rust, pipe scale, an FRL Products and Accessories High Flow FRL Series 50 Series Filters 44 50 Series Regulators 45 50 Series Pilot Operated Regulators 46 50 Series Lubricators 48 50 Series Filter/Regulator/Lubricator Combinations

More information

Models P, P, P, , DANGER

Models P, P, P, , DANGER Installation and maintenance guide Air filter Models 600104P, 600106P, 600108P, 600112, 600116 Date of issue January 2015 Form number 404646B Section G10 Page 31B DANGER Read manual prior to installation

More information

26 SERIES FILTER Operating Instructions and Parts List

26 SERIES FILTER Operating Instructions and Parts List 90-400* (revised 01/05) Questions regarding this form should be directed to the following: 732-390-8480 26 SERIES FILTER Operating Instructions and Parts List Application: The 26 Series Filter is rugged,

More information

CORRECT SELECTION OF COMPRESSED AIR PROCESSING EQUIPMENT

CORRECT SELECTION OF COMPRESSED AIR PROCESSING EQUIPMENT CORRECT SELECTION OF COMPRESSED AIR PROCESSING EQUIPMENT Most SHAVO units are available in port sizes from 1/8 to 2 and there is a wide choice of filter elements and regulating and relief spring ranges

More information

F64G. Typical flow with 40 µm element at 90 psig (6.3 bar) inlet pressure and a 5 psig (0.35 bar) pressure drop. F64G- N - D 1/4 2 3/8 3 1/2 4 3/4 6

F64G. Typical flow with 40 µm element at 90 psig (6.3 bar) inlet pressure and a 5 psig (0.35 bar) pressure drop. F64G- N - D 1/4 2 3/8 3 1/2 4 3/4 6 Olympian Plus eneral Purpose Filter F, FE eneral purpose filters Olympian Plus plug in system Effective liquid removal and positive solid particle filtration Large filter element area provides minimum

More information

ZTF. Compressed Air Filters scfm INNOVATIVE COMPRESSED AIR SOLUTIONS FILTER ASSEMBLIES ELEMENT OPTIONS SPECIFICATIONS ACCESSORIES

ZTF. Compressed Air Filters scfm INNOVATIVE COMPRESSED AIR SOLUTIONS FILTER ASSEMBLIES ELEMENT OPTIONS SPECIFICATIONS ACCESSORIES INNOVATIVE COMPRESSED AIR SOLUTIONS COMPRESSED AIR SOLUTIONS Compressed Air Filters 15-1600 scfm FILTER ASSEMBLIES ELEMENT OPTIONS SPECIFICATIONS ACCESSORIES Z E K S Z T F C O M P R E S S E D A I R F I

More information

74 Series Combination Filter/Regulator and Lubricator Unit, featuring an in-line shut-off valve, and Quikclamp system.

74 Series Combination Filter/Regulator and Lubricator Unit, featuring an in-line shut-off valve, and Quikclamp system. NCA-33 January 1998 Supersedes November 199 EXCELON Series System Features...2 EXCELON Series Product Features... Filters F72G General Purpose Filters... F73G General Purpose Filters...8 F7G General Purpose

More information

Parker Global Air Preparation System. A complete air preparation system

Parker Global Air Preparation System. A complete air preparation system Parker Global Air Preparation System A complete air preparation system Catalogue 0750-UK September 2010 DECLARATIO OF COMPLIACE (ROHS) European Directive 2002/95/EC - RoHS (Restriction of use of certain

More information

LUBRICATORS. Lubricators 44

LUBRICATORS. Lubricators 44 LURITORS Most pneumatically operated equipment such as valves, cylinders, and air tools, require some form of lubrication to reduce equipment maintenance and prolong life. ir driven devices can be lubricated

More information

Air Filtration CLEARPOINT. energy saving compressed air filtration. Truth in Compressed Air.

Air Filtration CLEARPOINT. energy saving compressed air filtration. Truth in Compressed Air. Air Filtration CLEARPOINT energy saving compressed air filtration Truth in Compressed Air. At a Glance CLEARPOINT Filters uring compressed air generation and distribution, contaminants are introduced to

More information

COMPRESSED AIR FILTERS

COMPRESSED AIR FILTERS VALUE THROUGH PERFORMANCE D SERIES COMPRESSED AIR FILTERS Combining Advanced Technology with Traditional Deltech Quality D Series Filters D Series Benefits Easy element changeout Bowl is hand-threaded

More information

Filters, Gauges, Regulators

Filters, Gauges, Regulators Filters, s, Regulators SCFM = Cubic ft/min at Ambient Condition s Sold Separately s...1/4" Flow SCFM...21 s...1/4" Flow SCFM...15 Filters - Construction Mini 1/4" 3000 Regulators Without Mini 1/4" 3100

More information

Flow Controls & Accessories

Flow Controls & Accessories Flow ontrols & ccessories Section Flow ontrol Valves SPF Series...2 337 Series...3 3250 Series... 4-5 Right ngle Series... 6-9 Needle Valves SPN Series...10 338 Series...11 SP Series heck Valve...12 339

More information

INSTRUCTION MANUAL FLUID POWER DIVISION Miniature Series. F300, R160, R260, R2424 & L180 Mini Particulate Filter Regulator Lubricator...

INSTRUCTION MANUAL FLUID POWER DIVISION Miniature Series. F300, R160, R260, R2424 & L180 Mini Particulate Filter Regulator Lubricator... INSTRUCTION MANUAL FLUID POWER DIVISION Miniature Series Pages 2-3 F300, R160, R260, R2424 & L180 Mini Particulate Filter Regulator Lubricator..................... F500 Mini Coalescing Filter.....................................................................

More information

AIR TREATMENT ACCESSORIES

AIR TREATMENT ACCESSORIES 6 AIR TREATMENT ACCESSORIES AIR FILTERS- Watts Removes water condensate, and particulates from air stream. Removal rating: 40 microns Part# WATTS # SIZE BOWL S1105 F602-02BJ 1/4" plastic 51.01 S1099 F602-03BJ

More information

ARO-FLO SERIES FILTERS, REGULATORS AND LUBRICATORS

ARO-FLO SERIES FILTERS, REGULATORS AND LUBRICATORS ARO-FLO SERIES FILTERS, REGULATORS AND LUBRICATORS For more than years, Ingersoll Rand ARO has been an industry leader in the design and ARO-Flo Series manufacture of compressors, pneumatic tools, and

More information

F200 Series. Compressed Air and Gas Filters. Heavy duty cast aluminum housings. Maximum working pressure 250 PSIG. Nine filtration grades

F200 Series. Compressed Air and Gas Filters. Heavy duty cast aluminum housings. Maximum working pressure 250 PSIG. Nine filtration grades F200 Series Compressed Air and Gas s FEATURES Heavy duty cast aluminum housings Maximum working pressure 250 PSIG Nine filtration grades Push on filter elements BENEFITS OF THE F200 SERIES Rugged construction

More information

Sliding Seal & Brass Poppet Valves

Sliding Seal & Brass Poppet Valves Sliding Seal & rass Poppet Valves anually Operated Section PL / VL Series... 2-3 HV Valve... 4-5 Hand Operated Valves,... 6-7 utton Operated Valves...8 Hand / Cam utton Valves...9 leed Valve...10 old text

More information

Installation & Service Instructions

Installation & Service Instructions 49124597 Revision A August 2015 PacE Flow Controller, Replacement Kit Installation & Service Instructions Save These Instructions Table of contents INTRODUCTION...........................................................................

More information

F200 Series. Compressed Air and Gas Filters FEATURES. Heavy duty cast aluminum housings. Maximum working pressure 250 PSIG. Nine filtration grades

F200 Series. Compressed Air and Gas Filters FEATURES. Heavy duty cast aluminum housings. Maximum working pressure 250 PSIG. Nine filtration grades F200 Series Compressed Air and Gas s FEATURES Heavy duty cast aluminum housings Maximum working pressure 250 PSIG Nine filtration grades Push on filter elements BENEFITS OF THE F200 SERIES Rugged construction

More information

Flow Controls & Accessories

Flow Controls & Accessories Flow ontrols & ccessories Section V V Flow ontrol Valves SPF Series...2 337 Series...3 3250 Series... 4-5 Miniature Right ngle...6 3251 Series...7 FM701 & FM703 Series...8 F701, F702, FS701 Series...9

More information

Air Preparation Products. For Low Temperature Service. Parker Hannifin Corporation Pneumatic Division Richland, Michigan

Air Preparation Products. For Low Temperature Service. Parker Hannifin Corporation Pneumatic Division Richland, Michigan Air Preparation Products For Low Temperature Service Catalog -E Miniature R Series R Regulators Miniature Miniature Regulators /8", /" Basic /8" Body R-C Non- R-MC Features Diaphragm operated for fast

More information

12 Series Miniature FRLs

12 Series Miniature FRLs 12 Miniature FRLs www.numatics.com Table of Contents 12 Features and Benefits 3 Particulate Filter 4 Coalescing Filter 5 Regulator 6 Particulate Filter/Regulator 7 Coalescing Filter/Regulator 8 Lubricator

More information

Filters, regulators, and lubricators

Filters, regulators, and lubricators Filters, regulators, and lubricators 28 filters 3/8", 1/2", and 3/4" Ports Technical data Polycarbonate bowl Polycarbonate bowl guard Metal bowl Metal bowl sight glass Filter body Manual drain Auto drain

More information

Your Plant Deserves Pure-Aire!

Your Plant Deserves Pure-Aire! Your Plant Deserves Pure-Aire! PF Series High Efficiency Filters High Technology Filter Elements The Pure-Aire PF Series High Efficiency Unique Push-Fit, Double O-Ring Seal filter-to-head chamfered connection

More information

Manufacturers of Premium Pneumatic Controls since 1921 ROSS CONTROLS ROSS CONTROLS ROSS CONTROLS

Manufacturers of Premium Pneumatic Controls since 1921 ROSS CONTROLS ROSS CONTROLS ROSS CONTROLS Manufacturers of Premium Pneumatic Controls since 1921 ROSS CONTROLS ROSS CONTROLS ROSS CONTROLS New Product Introduction 400 PSI High Pressure Regulator Ports: 1/8, 1/4, 3/8 Problem: Most spring activated

More information

Inside. Introducing GROZ Air - air control units. Air Regulators 05. Air Lubricators - Metal Bowl 09. Filter Regulator Combination 10.

Inside. Introducing GROZ Air - air control units. Air Regulators 05. Air Lubricators - Metal Bowl 09. Filter Regulator Combination 10. Introducing GROZ Air - air control units ALUMINIUM DIE CAST BODY 01 02 WALL MOUNTING BRACKET FILTER UNIT 05 06 SINTERED BRONZE FILTERING ELEMENT (inside) 03 BUILT IN PIPING ADAPTERS PRESS TYPE MANUAL DRAIN

More information

Modulating Water Valves and Bulb Wells

Modulating Water Valves and Bulb Wells Modulating Water Valves and ulb Wells PPLITION: These modulating valves regulate the flow of water to the heat exchanger to maintain a desired exiting oil temperature. They open automatically when temperature

More information

I-4057-F CleanAir Air Control Equipment. Accessories for superior spray finishing. Filters Regulators Gauges Valves WATERBORNE COMPATIBLE

I-4057-F CleanAir Air Control Equipment. Accessories for superior spray finishing. Filters Regulators Gauges Valves WATERBORNE COMPATIBLE I-4057-F 2-01 CleanAir Air Control Equipment Accessories for superior spray finishing. Filters Regulators Gauges Valves WATERBORNE COMPATIBLE Air control equipment for today s spray finishing challenges.

More information

BERMAD Waterworks. Pressure Relief/Sustaining Valve. Model: WW Series. Features and Benefits. Major Additional Features

BERMAD Waterworks. Pressure Relief/Sustaining Valve. Model: WW Series. Features and Benefits. Major Additional Features Pressure Relief/Sustaining Valve Prioritizing pressure zones Ensuring controlled pipeline fill-up Preventing pipeline emptying Pump overload & cavitation protection Safeguarding pump minimum flow Excessive

More information

AFM20-A AFD20-A. (ANR) ( 0.8 ppm) MAX 0.1 mg/m 3 (ANR) (Before saturated with oil 0.01 mg/m 3 Note 2) Note 3) Semi-standard (Steel) 0.

AFM20-A AFD20-A. (ANR) ( 0.8 ppm) MAX 0.1 mg/m 3 (ANR) (Before saturated with oil 0.01 mg/m 3 Note 2) Note 3) Semi-standard (Steel) 0. ist Separator Series F2- to F4- icro ist Separator Series F2- to F4- Standard Specifications ote 1) Conditions: Inlet pressure:.7 Pa; The rated flow varies depending on the inlet pressure. Keep the air

More information

Flow Control Valves Check Valves Gauge Control Valves. Colorflow Valves

Flow Control Valves Check Valves Gauge Control Valves. Colorflow Valves Check Valves Gauge Control Valves Colorflow Valves Colorflow and Ball Valves Industrial Flow Control, Check, Gauge Control Catalog HY14-3300/US Colorflow and Ball Valves Fully guided poppets are used on

More information

DWS 41. Installation Data 44 Performance Specs DWS & DW-PRV Series

DWS 41. Installation Data 44 Performance Specs DWS & DW-PRV Series IRRIGATION Title Description Details Page Intro 3 2000 Series 4 Model 2000 Solenoid 1 3 12 Model 2000 Solenoid 4 8 15 Model 2030 Low Power Solenoid 1 3 17 Model 2030 Low Power Solenoid 4 8 19 Model 2160

More information

Breathers: VentGuards Basic protection from moisture and particulate contamination in lubricant and equipment

Breathers: VentGuards Basic protection from moisture and particulate contamination in lubricant and equipment Breathers: VentGuards Basic protection from moisture and particulate contamination in lubricant and equipment Applications: Gearboxes Low-Flow High-Humidity Washdown The Overview Standard Breathers: Typical

More information

FLEXIBLOK FRL Series

FLEXIBLOK FRL Series FRL Products and Accessories FLEXIBLOK FRL Series STOCKBLOK & MODUBLOK Combinations 14 14/22/32 Series Particulate Filters 20 14/22/32 Series Coalescing Filters 22 14/22/32 Series Regulators 24 14 Series

More information

RAZOR. RAZOR HVLP Spray Guns

RAZOR. RAZOR HVLP Spray Guns RAZOR RAZOR HVLP Spray Guns Provides generous material flow that helps you get the job done quickly Offers exceptional atomization rate Promotes a superior finish Proven effective for clear coat, base

More information

Breathers: VentGuards Basic protection from moisture and particulate contamination in lubricant and equipment

Breathers: VentGuards Basic protection from moisture and particulate contamination in lubricant and equipment Breathers: VentGuards Basic protection from moisture and particulate contamination in lubricant and equipment Des-Case Corporation 675 N. Main St. Goodlettsville, TN 37072 (615) 672-8800 Fax (615) 672-0701

More information

3000 Series filters 3/4" and 1" Ports

3000 Series filters 3/4 and 1 Ports 38 filters 3/4" and 1" Ports Technical data Metal bowl Metal bowl sight glass Filter body Manual drain Auto drain Standard filter Coalescing filter Seals Filter baffle Aluminum Nylon Aluminum Brass + nitrile

More information

Air Service Units Filter pressure regulator + Lubricator - Size 1. Series Technical characteristics. Construction and working characteristics

Air Service Units Filter pressure regulator + Lubricator - Size 1. Series Technical characteristics. Construction and working characteristics ir Service Units Filter pressure regulator + Lubricator - Size Series 00 Construction and working characteristics - Zinc alloy body or reinforced technopolymer body with threaded brass insert connections.

More information

Introduction to Inline Lubrication. Master Pneumatic

Introduction to Inline Lubrication. Master Pneumatic Introduction to Inline Lubrication Master Pneumatic What is the purpose of Inline Lubrication? Sentry Introduce atomized oil into the compressed air line to lubricate: Air Motors Cylinders Gears Sliding

More information

PRESSURE REGULATORS. GUIDE to REGULATORS and SERVO VALVES

PRESSURE REGULATORS. GUIDE to REGULATORS and SERVO VALVES Master Pneumatic regulators are made in a wide range of sizes to suit nearly all industrial requirements for pneumatic pressure regulation. Good pressure regulation is essential to the efficient use of

More information

Section: D Alternative Fuel

Section: D Alternative Fuel Section: D Alternative Fuel aerospace climate control electromechanical filtration fluid & gas handling hydraulics pneumatics process control sealing & shielding C Alternative Fuel Table of Contents Alternative

More information

Sinclair Collins. Process Control Valves. For Steam, Hot and Cold Liquids -40 to 450 F up to 500 psi. Catalog SCV-100/USA April 2001

Sinclair Collins. Process Control Valves. For Steam, Hot and Cold Liquids -40 to 450 F up to 500 psi. Catalog SCV-100/USA April 2001 Sinclair Collins Process Control Valves For Steam, Hot and Cold Liquids -40 to 450 F up to 500 psi April 2001 The Diaphragm Operated Valves on the following pages are designed for directing, diverting

More information

AIR LINE ACCESSORIES 372

AIR LINE ACCESSORIES 372 372 Series AIRPRO IN-LINE FILTERS Compressed air may contain impurities which will cause improper operation of equipment, and in some cases equipment failure. In-line filters will reduce downtime and prevent

More information

Air Preparation Products 652 Series Filter Regulator (FR) for Process Industry Applications

Air Preparation Products 652 Series Filter Regulator (FR) for Process Industry Applications Air Preparation Products Series Filter Regulator (FR) for Process Industry Applications www.asconumatics.eu Table of Contents Series Particulate Filter/Regulator 2 Particulate Filter 5 Regulator 8 Kits

More information

Air Preparation Units Filters, Regulators and Lubricators

Air Preparation Units Filters, Regulators and Lubricators ulletin 1300-703-2/US Filtration ir Preparation Units Filters, Regulators and Lubricators FRL pplications Filtration ircraft ealers ircraft Servicing musement Parks utomation Systems utomobile ody Repairing

More information

Lubricator Series Functional explanation / Dimensions

Lubricator Series Functional explanation / Dimensions 00E/00E Series Lubricator / utofill type Only installing oil tank enables lubrication to multiple lubricator. : Rc/ to Rc JIS symbol ir uto. drain Specifications escriptions 00E///V 00E/8V ompact lean

More information

Page General Purpose Filter Replacement Filter Elements Bowl Assemblies Accessories & Optional Extras

Page General Purpose Filter Replacement Filter Elements Bowl Assemblies Accessories & Optional Extras New Comprehensive Accessory & Maintenance Kit Listing Page.009 General Purpose Filter Replacement Filter Elements Assemblies Accessories & Optional Extras Page.05 Relief Valve Accessories and Optional

More information

A-4000 Series Oil Removal and Pressure-Reducing Stations and Air Compressor Accessories

A-4000 Series Oil Removal and Pressure-Reducing Stations and Air Compressor Accessories A-4000 Series Oil Removal and Pressure-Reducing Stations and Air Compressor Accessories Installation Applications The A-4000 Series Oil Removal and Pressure-Reducing Stations (see Figure 1, Figure 2, Figure

More information

Air Preparation Products

Air Preparation Products Air Preparation Products Series Series Filter Regulator Lubricator (FRL) www.asco.com Table of Contents / Series Product Overview 2 Particulate Filter 4 Coalescing Filter 8 Adsorber Activated Carbon 8

More information

P31EB 2 E N P. Element. 5µ Element E. Poly bowl with bowl guard Metal bowl without sight gauge. Height mm (inches) Max. bar (psig)

P31EB 2 E N P. Element. 5µ Element E. Poly bowl with bowl guard Metal bowl without sight gauge. Height mm (inches) Max. bar (psig) Series ini Filter / Regulator - Symbols Integral /" ports (NT & BS) High efficiency micron element as standard Excellent water removal efficiency Robust but lightweight aluminum construction ositive bayonet

More information

Soft Start-up Valve. AV2000/3000/4000/5000 Series

Soft Start-up Valve. AV2000/3000/4000/5000 Series Soft Start-up Valve V000/000/000/000 Series [Option] C- R- W- C R - W - Start-up valve for low speed air supply to gradually raise initial pressure in an air system and for quick exhaust by cutting off

More information

1 6 / 2 6 S E R I E S C O M P A C T & S T A N D A R D M O D U L A R A I R P R E P A R A T I O N S Y S T E M S

1 6 / 2 6 S E R I E S C O M P A C T & S T A N D A R D M O D U L A R A I R P R E P A R A T I O N S Y S T E M S 16/26 SRIS O M P T & S T N R M O U L R I R P R P R T I O N S Y S T M S WILKRSON FILTRS, RGULTORS N LUBRITORS R26 Regulator F26 Filter L26 Lubricator M16 oalescing Filter B6 Filter/Regulator w/ Optional

More information

Air Preparation Products. Air Preparation Products. Section E. Air Preparation Products. Catalog PDN1000-3US Parker Pneumatic

Air Preparation Products. Air Preparation Products. Section E. Air Preparation Products. Catalog PDN1000-3US Parker Pneumatic Section 1 Catalog PDN1000-3US (Revised 05-15-14) Pictorial Index - www.parker.com/pneu/airprep Pictorial Index Global FRL s 3 size: 1/4 through 3/4 inch Maximum supply pressure: 300 PSIG Operating temperature:

More information

Introduction Parker Series spring return (AC/AO) or double acting (AD) rack and pinion actuators are compact, simply designed devices that are quality

Introduction Parker Series spring return (AC/AO) or double acting (AD) rack and pinion actuators are compact, simply designed devices that are quality Pneumatic Actuators Catalog 4123-PA Revised, April 22 Introduction Parker Series spring return (AC/AO) or double acting (AD) rack and pinion actuators are compact, simply designed devices that are quality

More information

Power Valve Precision Regulator

Power Valve Precision Regulator Power Valve Precision Regulator VEX Series High precision, large capacity relief regulator port large exhaust capacity pressure reducing valve which utilizes a nozzle flapper mechanism available as air

More information

Type FL Pressure Reducing Regulators

Type FL Pressure Reducing Regulators ulletin 71.2 D103067X012 Type FL January 2017 Type FL Pressure Reducing Regulators Features No tmospheric leed Eliminates nuisance and wasteful bleed gas to atmosphere by utilizing a self-contained control

More information

A-4000 Series Oil Removal and Pressure Reducing Stations & Air Compressor Accessories

A-4000 Series Oil Removal and Pressure Reducing Stations & Air Compressor Accessories Pneumatic Air Supply Manual 718 Filter Stations Section Product Bulletin Issue Date 0907 A-4000 Series Oil Removal and Pressure Reducing Stations & Air Compressor Accessories Oil Removal and Pressure Reducing

More information

Fluid Power Accessories

Fluid Power Accessories Fred C. Gilbert Co. 106 Norris Road Bakersfield, Ca. 93308 661-399-9569 fax 661-393-9654 PNEUMATIC EXHAUST MUFFLERS Breather Vents 2,3 Exhaust Mufflers 2-5 Reclassifiers / Mufflers 6,7 BREATHER VENTS Speed

More information

Catalog 080-/USA Notes Vacuum Control Valves

Catalog 080-/USA Notes Vacuum Control Valves Vacuum Control Valves Section Catalog 080-/USA Notes Vacuum Control Valves Catalog 080-/USA Index Vacuum Control Valves VA0 Vacuum Control Valves for Centralized Vacuum Systems VA0PSV & VA0PSP, -Port,

More information

Booster Pump Control Valve

Booster Pump Control Valve MODEL 60-7 660-7 ooster Pump Control Valve Simple Hydraulic Operation Low Head Loss Horizontal or Vertical Mounting uilt-in Check Valve Proven Reliable Design The Cla-Val Model 60-7/660-7 ooster Pump Control

More information

Air Filter Outdoor Series FW4000/FW8000-W Series Outdoor types now developed into a series. Port size: 1/4 to 1 JIS symbol Specifications Description

Air Filter Outdoor Series FW4000/FW8000-W Series Outdoor types now developed into a series. Port size: 1/4 to 1 JIS symbol Specifications Description ir Filter Outdoor Series FW4000/FW8000-W Series Outdoor types now developed into a series. : 1/4 to 1 JIS symbol Specifications FW4000-W FW8000-W Working fluid ompressed air Max. working pressure MPa 1.0

More information

Super Charged Piston Pumps Variable Displacement For Open Circuits. PAVC Medium Pressure

Super Charged Piston Pumps Variable Displacement For Open Circuits. PAVC Medium Pressure aerospace climate control electromechanical filtration fluid & gas handling hydraulics pneumatics process control sealing & shielding PAVC Medium Pressure Super Charged Piston Pumps Variable Displacement

More information

Crispin Valves Operating Guide. Crispin

Crispin Valves Operating Guide. Crispin Crispin Valves Operating Guide Crispin Since 1905 Crispin Multiplex Manufacturing Co. 600 Fowler Avenue Berwick, PA 18603 1-800-AIR-VALV T: (570) 752-4524 F: (570) 752-4962 www.crispinvalve.com sales@crispinvalve.com

More information

Master Pneumatic Detroit, Inc. Micro-Lubrication Specialists. Precision Lubrication Systems for Air Tools, Hoists, and Air Motors

Master Pneumatic Detroit, Inc. Micro-Lubrication Specialists. Precision Lubrication Systems for Air Tools, Hoists, and Air Motors Master Pneumatic Detroit, Inc. Micro-Lubrication Specialists Precision Lubrication Systems for Air Tools, Hoists, and Air Motors Master Pneumatic delivers The critical nature of precision lubrication of

More information

Flow Controls & Accessories

Flow Controls & Accessories ontrols & ccessories Section Y ontrol Valves SPF Series... 2 337 Series... 3 3250 Series... 4-5 Miniature Right ngle... 6 3251 Series... 7 FM701 & FM703 Series... 8 F701, F702, FS701 Series... 9 Needle

More information

Ready for outdoor use too!

Ready for outdoor use too! Filter/regulator assured for outdoor use New Product Filter/regulator series First in the industry FILTER REGULATOR FOR DOOR USE Ready for outdoor use too! Improved outdoor durability due to the exterior

More information

PRESSURE REDUCING VALVE

PRESSURE REDUCING VALVE Schematic Throttles to reduce high upstream pressure to constant lower downstream pressure Closes quickly when downstream pressure exceeds reduced pressure setpoint 3 PRESSURE REDUCING VALVE with SURGE

More information

Racor 75500FGX Turbine Series fuel

Racor 75500FGX Turbine Series fuel Installation Instructions 75500FGX Fuel Filter Racor 75500FGX Turbine Series fuel filter/water separator assemblies are designed to be installed on the vacuum side of the fuel transfer pump for best efficiency

More information

Type MR108 Direct-Operated Backpressure Regulators

Type MR108 Direct-Operated Backpressure Regulators July 2016 Type MR108 Direct-Operated Backpressure Regulators P1202_1 P1203_1 Type mr108 with low-pressure Actuator Type mr108 with high-pressure actuator Figure 1. Type MR108 Direct-Operated Backpressure

More information

WARCO CHEMAG SERIES GH FILTERS

WARCO CHEMAG SERIES GH FILTERS WARCO CHEMAG SERIES GH FILTERS High Performance Pleated & Bag Type Filtration Systems INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS Thank you for your purchase of a WARCO Series GH Filtration System.

More information

Compressed Air Filters

Compressed Air Filters ompressed ir s Operating pressure onnection thread Device age max. bar bronze In-Line- 21 G¼ - G½ 137.02 In-Line- 0,3 μm 9 nipple Ø 4. 6 mm F400.02 Miniature -Series 21 G 1 8 and G¼ F504.03 made of plastic

More information

ACHL Series Pump. Operation and Maintenance Manual Air Driven, Hand Operated High Pressure Liquid Pump

ACHL Series Pump. Operation and Maintenance Manual Air Driven, Hand Operated High Pressure Liquid Pump ACHL Series Pump Operation and Maintenance Manual Air Driven, Hand Operated High Pressure Liquid Pump Catalog: 02-9245ME February 2013 Model # Serial # Drawing # Order # Mfg. Date Table of Contents page

More information

To ensure proper installation, digital pictures with contact information to before startup.

To ensure proper installation,  digital pictures with contact information to before startup. Check List for Optimal Filter Performance? There should be no back-pressure on the flush line. A 1 valve should have a 2 waste line, and 2 valve should have a 3 waste line. Do not use rubber hosing or

More information

Filters for Compressed Air

Filters for Compressed Air Fine Filtration Systems for Industry Product Information Filters for Compressed Air Tel: +49 (0) 6232 24021 Fax: +49 (0) 6232 24025 Email: info@headlinefilters.de Website: www.headlinefilters.de COALESCING

More information

Air Filter. Best Pneumatics 4. Equipment. Air Line

Air Filter. Best Pneumatics 4. Equipment. Air Line est Pneumatics Air Filter Air Filter: AF000 to 6000 P..- Mist Separator: AFM000/000/00 P..-6 Micro Mist Separator: AF000/000/00 P..-9 Large Flow Air Filter: AF00/0 P..- Air Line Equipment.-0 Modular Style

More information

Model Model Model

Model Model Model Filter Separators Model 9003 Model 9004 Model 9001 & 9032 Model 9002 EXAIR's Filter Separators remove water, dirt and rust from your compressed air system. They prevent these contaminants from plugging

More information

MOISTURE MEETS ITS MATCH

MOISTURE MEETS ITS MATCH Donaldson Delivers T.R.A.P. Breather Technology For Hydraulic and Lube Oil Reservoirs MOISTURE MEETS ITS MATCH Donaldson T.R.A.P. breathers collect and expel the moisture out of reservoirs, which means

More information

Rotary Plug Valves (PR Series) Catalog 4126-PR Revised, July 2003

Rotary Plug Valves (PR Series) Catalog 4126-PR Revised, July 2003 Rotary Plug Valves (PR Series) Catalog 4126-PR Revised, July 2003 PR Series Rotary Plug Valves Introduction Parker PR Series Plug Valves provide positive leak tight shut-off, high flow capacity, and quick

More information

Colorflow and Ball Valves. Industrial Flow Control, Check, Gauge Control. Catalog HY /US

Colorflow and Ball Valves. Industrial Flow Control, Check, Gauge Control. Catalog HY /US Colorflow and Industrial Flow Control, Check, Gauge Control Catalog HY14-3300/US Colorflow and Fully guided poppets are used on Colorflow valves rather than the less durable ball-check type construction.

More information

A Filtration Primer. Filter Elements. High Pressure Filters. Tank-Mounted, Return Line and Medium Pressure Filters. Water Service Filters

A Filtration Primer. Filter Elements. High Pressure Filters. Tank-Mounted, Return Line and Medium Pressure Filters. Water Service Filters A Filtration Primer Filter Elements High Pressure Filters Tank-Mounted, Return Line and Medium Pressure Filters Water Service Filters Section 6 Reservoir Accessories SCHROEDER INDUSTRIES 259 Principles

More information

Marine Turbine Series

Marine Turbine Series 1000MA Water-in-fuel sensor and indicator. All Racor filter materials and seals are compatible with ultra-low sulphur diesel (ULSD) fuel and B2 to B20 Biodiesel. See Racor bulletin 7679. The complete Primer

More information

PRESSURE REDUCING VALVE

PRESSURE REDUCING VALVE Schematic Throttles to reduce high upstream pressure to constant lower downstream pressure Low Flow By-Pass controls at low flows 4 PRESSURE REDUCING VALVE with LOW-FLOW BY-PASS FEATURE Main Line valve

More information

All Racor filter materials and seals are compatible with ultra-low sulphur diesel (ULSD) fuel and B2 to B20 Biodiesel. See Racor bulletin 7679.

All Racor filter materials and seals are compatible with ultra-low sulphur diesel (ULSD) fuel and B2 to B20 Biodiesel. See Racor bulletin 7679. 000MA Water-in-fuel sensor and indicator. MA units have shielded see-thru bowls; MAM bowls are all-metal. UL-listed drain valve and water sensor probe options are available. Turbine Series Electric Primer

More information

Super Charged Piston Pumps Variable Displacement For Open Circuits. PAVC Medium Pressure

Super Charged Piston Pumps Variable Displacement For Open Circuits. PAVC Medium Pressure aerospace climate control electromechanical filtration fluid & gas handling hydraulics pneumatics process control sealing & shielding PAVC Medium Pressure Super Charged Piston Pumps Variable Displacement

More information

VB-9313 Series. Application. Features. Applicable Literature

VB-9313 Series. Application. Features. Applicable Literature V-9313 Series 2-1/2" and 3" Screwed NPT 2-1/2" to 6" 125 Lb. Flanged Three-Way Mixing s General Instructions pplication V-9313 series three-way mixing valves control hot or chilled water in heating or

More information

Air Control Kit INSTRUCTIONS-PARTS LIST. Table of Contents HIGH VOLUME. 250 psi (1.7 MPa, 17.2 bar) Maximum Air Inlet Pressure

Air Control Kit INSTRUCTIONS-PARTS LIST. Table of Contents HIGH VOLUME. 250 psi (1.7 MPa, 17.2 bar) Maximum Air Inlet Pressure INSTRUCTIONS-PARTS LIST INSTRUCTIONS This manual contains important warnings and information. READ AND KEEP FOR REFERENCE. 308 648 Rev. B Supersedes A HIGH VOLUME Air Control Kit 250 psi (.7 MPa, 7.2 bar)

More information

Product Information ROSS CONTROLS

Product Information ROSS CONTROLS Product Information Minimize Hose Whip Flow Diffuser AIR-FUSE 19 Series ROSS CONTROLS AIR-FUSE Flow Diffusers Minimize Hose Whip 19 Series The ROSS AIR-FUSE Flow Diffuser automatically reduces air flow

More information