1 Catalog HY15-352/US Contents SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. LPM/GPM BAR/PSI PRESSURE RELIEVING AP1B2YP... 2G... Increase /Increase Current...5.3/ / AP2B2YP... C Increase /Increase Current...5.3/ / AP4G2YP... C Increase /Increase Current...45/ / AP1B2YR... 2G... Decrease /Increase Current...5.3/ / AP2B2YR... C Decrease /Increase Current...5.3/ / AP4G2YR... C Decrease /Increase Current...95/ / PRESSURE REDUCING GP Reducing Valve...1.9/ / GTP C Reducing Valve...19/ / GTP X... Reducing Valve...3/ / FLOW CONTROLS, 2-Way DF122C... C Control, N.C....53/ / DF161C... C Control, N.C....15/ / DF21C... C Control, N.C / / HP2C... 2X... Control, N.C....23/ / JP2C... C Control, N.C....23/ / HP4C... C Control, N.C....36/ / JP4C X... Control, N.C....36/ / DFA125C21*... C12-3L... Control, N.C / / *The DFA125C21 will be available January 1, 211. HP2P... 2X... Control, N.O....19/ / JP2P... C Control, N.O....19/ / HP4P... C Control, N.O....3/ / JP4P... 3X... Control, N.O....36/ / DF122N... C Control, N.O....53/ / FLOW CONTROLS, 3-WAY JP4C C... Priority Control, N.C....3/ / DFA125C31... C12-4L... Priority Control, N.C / / s & DIRECTIONAL CONTROL GP C Way, 3 Pos - Closed Center...21/ / GP C Way, 3 Pos - Float Center...17/ / DSP15C1... C Way, 3 Pos - Closed Center...32/ / DSP15C4... C Way, 3 Pos - Float Center...32/ /

2 Catalog HY15-352/US Tips Control INTRODUCTION This technical tips section is designed to help familiarize you with the Parker line of. In this section we present common options, technical terms, as well as a brief synopsis of the operation and applications of the various products offered in this section. The intent of this section is to help you in selecting the best products for your application. s & COMMON OPTIONS As you will see, Parker offers a variety of Valve products. As such, some of the options mentioned below may not be available on all valves. Consult the model coding and dimensions for each valve for specifics. Here are some of the common options available. Seals: The majority of the products are available in Nitrile or Fluorocarbon Seals. The Winner s Circle products feature a standard 431 Polyurethane D -Ring. The D -Ring eliminates the need for backup rings. You should match the seal compatibility to the temperature and fluid being used in your application. TECHNICAL TERMS To help in applying our proportional valve line of product, we have listed some technical terms below, as well as some helpful hints in applying our valves. Ohm s Law: Electrical current is generated as a result of the relationship between input voltage and the resistance to the flow of electrical current. It is represented in equation form by I = V/R (or V=IR), where I is current, V is voltage and R is resistance. This is an important relationship to remember when dealing with any electrically operated valves. valves allow varying control of flow or pressure, dependant on the current signal provided. As coils heat up, their resistance rises. This means a higher voltage must be available to maintain the same amount of pressure or flow. Thus, the application needs to be designed such that the full on position is about 7% of the initial current draw. On the individual catalog pages a maximum control current is specified to help in applying our proportional valves. PWM: Pulse Width Modulation (PWM) is the preferred signal for controlling electrical current. PWM is on / off voltage in a square wave form. The percent on time or duty cycle provides the average voltage. The valve driver adjusts the duty cycle to obtain current control. We recommend valve drivers with current control for optimum performance. PWM signals also usually provide dither for the proportional valve. Dither is a Overrides: Overrides are standard on many of the Parker proportional valves. The override is generally a push type that is flush with the end of the tube. Consult the individual catalog pages for more details. small back and forth movement of the valve spool around its set position. This rapid movement reduces the friction of the valve and leads to faster, more accurate response. PWM Frequency: The frequency of a PWM signal is the rate at which the signal is turned on and off. Parker s analog proportional valves are designed to work with low frequency responses between 1-4 Hz. The performance curves on our catalog pages were performed with a PWM signal at 2 Hz. Hysteresis: Due to various factors, the performance of a proportional valve will show a slightly different performance when the current signal is increasing than it will when the signal is being decreased. This difference is usually expressed as a percentage of total input change and is referred to as the hysteresis of the valve. Deadband: Cracking or deadband refers to the amount of the control signal that is needed to produce any movement of the spool. Thus, a 2% deadband means that 2% of the control signal is needed before the spool will move. 1

3 Catalog HY15-352/US Tips Control s & PRODUCT TYPES / APPLICATIONS valves are nothing more than electrically adjustable hydraulic valves. They give the operator nearly infinite adjustment control and flexibility. Parker Hannifin offers various types of proportional flow control, pressure reducing, and relief valves. Control Valve flow control valves provide pseudo pressure compensation and are used on systems requiring variable electronic control of flow. They allow the operator to vary the control signal to accelerate or decelerate an actuator. A compensator valve can be added to the circuit for enhanced compensation. Some typical applications would include the hoist control for a lift, or the speed control for a winch circuit. Parker offers both normally closed and normally open versions of proportional flow controls. Normally Closed Control OPERATION - With the solenoid coil de-energized, the spool is held in a closed position by the spring force. When the solenoid coil is energized, the amperage of the signal moves the spool into an open position. The spool is held in this position by a balance between spring force and electrical force. As the current increases, the spools opens further; allowing more flow. As the current decreases, the spool begins closing; allowing less flow. Pseudo compensation is obtained by the pressure drop across the orifices in the spool. Normally Open Control OPERATION - With the solenoid coil de-energized, the spool is held in an open position by spring force; allowing full flow to pass. As the solenoid coil is energized, the spool begins to move away from a full open position; allowing less flow to pass. Once a full electronic signal is given, the spool is held in a closed position; allowing no flow to pass. As the electronic signal is then reduced, the spool begins to open; allowing flow to pass again. Once a constant electronic signal is given, the spool is held in that position by a balance between electronic force and spring force. Pseudo compensation is obtained by the pressure drop across the orifices in the spool. Normally Closed Needle Valve The proportional needle valves are electronic controlled variable needle valves. They are designed specifically for bleed off or unloading circuits as back pressure will affect performance. Port Is Not Used OPERATION - With the solenoid de-energized, the main Inlet poppet is held in the closed position by spring force. When the solenoid is energized, the sensing spool moves into a partially open position relative to the percentage of rated current flowing through the coil. This action allows the main poppet to move away from the valve seat to a degree that corresponds to sensing spool position. The valve will maintain a fixed amount of opening as long as the electrical current remains constant and will vary proportionally with an increase or decrease in current. In Outlet Out 2

4 Catalog HY15-352/US Tips Control Priority Bypass Control Bypass Inlet Reg. The proportional priority bypass (4) flow controls allow electronic Not Used control of the flow setting for the priority flow circuit. The priority flow remains constant regardless of changes in load or pressure. The excess inlet flow is diverted or bypassed to tank. The bypass port must not have any restrictions or performance will be hindered. OPERATION - enters the valve through port 3. With the coil de-energized, flow is bypassed to port 2. When the coil is energized, the internal orifice is increased allowing pressure compensated flow to the priority port (port 4). The excess flow is bypassed to port 2. As input current is increased, the priority flow increases and the bypass flow decreases. As the current is decreased, priority flow decreases and bypass flow is increased. Direct Acting, Normally Closed Reducing Valve T Direct acting, normally closed proportional pressure reducing valves are used to electronically reduce the inlet pressure to one leg of a hydraulic circuit. This valve is used Act. P when a fixed regulated pressure is required regardless of the inlet pressure. This valve could be used as a clutch control for power shift transmissions and PTO, or as a pilot control for directional control valves. OPERATION - With the solenoid coil de-energized, the spool is held in a closed position by spring force. In this mode, the regulated pressure port is open to tank and the pressure inlet is blocked. As current is applied to the solenoid coil, the spool will begin to travel to a position where the pressure inlet port is connected to the regulated pressure port. At this point, reduced pressure becomes a function of the current signal. As long as the current signal is constant, the reduced pressure at the regulated pressure port will remain fixed regardless of any changes in inlet flow or inlet pressure. As the current signal increases or decreases, the reduced pressure at the regulated pressure port will change with respect to the changes in signal. Once the coil is fully energized, the reduced pressure of the regulated pressure port will be at the maximum reduced pressure for that valve. s & 3

5 Catalog HY15-352/US Tips Control s & Normally Closed Reducing / Relieving Valve Normally Closed Reducing/Relieving are used to electronically reduce the inlet pressure to one leg of a hydraulic circuit. In addition these valves act as a relief valve, relieving any shocks or surges that occur between its regulating port and the actuator. Parker offers direct acting and pilot operated versions of this valve. The direct acting valves are faster responding and generally have lower hysteresis, but are limited to smaller reduced pressures (generally below 8 psi depending on the valve.) Pilot operated are generally slower on response due to the two stage performance, but can have a reduced pressure as high as 3 psi. Direct Acting OPERATION - With the solenoid coil de-energized, the spool is held in a closed position by spring force. In this mode, the regulated pressure port is open to tank and the pressure inlet port is blocked. As an electronic signal is applied to the solenoid coil, the spool will begin to travel to a position where the pressure inlet port is connected to the regulated pressure port. At this point, reduced pressure becomes a function of the voltage signal. As long as the electronic signal is constant, the reduced pressure at the regulated pressure port will remain fixed regardless of any changes in inlet flow or inlet pressure. As the electronic signal increases or decreases, the reduced pressure at the regulated port will change with respect to the change in electronic signal. Once a full signal is given, the reduced pressure of the regulated pressure port will be at the maximum reduced pressure for that valve. Reg. Tank Pilot Operated OPERATION - With the solenoid coil de-energized, the pilot dart is held open by the spring force. This allows the main spool to close and restricts flow from going from the inlet port to the regulated port. As the electronic signal is applied to the coil, the pilot dart is moved towards the pilot seat restricting pilot flow. This restriction raises the effective pressure inside the chamber between the spool and the pilot seat, allowing the spool to travel away from the pilot seat to a position where the pressure at inlet is connected to the regulated pressure port. At this point, reduced pressure becomes a function of the electronic signal. As long as the electronic signal is constant, the reduced pressure at the regulated pressure port will remain fixed regardless of any changes in inlet flow or inlet pressure. As the electronic signal increases or decreases, the reduced pressure at port will change with respect to the change in the electronic signal. Reg. In Tank 4

6 Catalog HY15-352/US Tips Control Normally Closed Relief Valve Normally closed proportional relief valves are used to electronically control the system pressure. These valves are ideal for circuits with varying system pressures demands. A small flow pilot version of the normally closed proportional relief is also offered for piloting a larger logic element or vented relief valve. The normally closed relief defaults to a maximum pressure setting (i.e. 3 psi) when there is no current applied. OPERATION - With the solenoid coil de-energized, the pilot dart is held closed by the spring. As current is applied to the coil, the pilot dart is moved creating less restriction of the pilot flow. As this restriction is reduced with the increasing current, the pressure setting also decreases. Once a constant electronic signal is given, the pilot dart is held in a given position, holding the pressure setting. This is maintained by the balance between the electronic spring force and the inlet pressure. s & Normally Open Relief Valve Normally open proportional relief valves are used to electronically control the system pressure. These valves are ideal for circuits with varying system pressure demands. A small flow pilot version of the normally open proportional relief is also offered for piloting a larger logic element or vented relief valve. The normally open relief defaults to minimum system pressure (i.e. 15 psi) when there is no current applied. Normally closed versions are also available upon request. OPERATION - With the solenoid coil de-energized, the pilot dart is held open by the spring. This allows the main spool to open at minimum pressure 1.4 Bar (15 psi). As current is applied to the coil, the pilot dart is moved towards the pilot seat restricting pilot flow. This restriction raises the effective pressure setting of the valve. Once a constant electronic signal is given, the pilot dart is held in a given position, holding the pressure setting. This is maintained by a balance between electronic spring force and inlet pressure. As the electronic signal is reduced, the pilot dart is moved away from the pilot seat. This lowers the effective pressure setting of the valve. 5

7 Catalog HY15-352/US Notes Tips Control s & 6

8 Catalog HY15-352/US Information General Description Relief Valve. Increasing With Increasing Current. For additional information see Tips on pages 1-6. Relief Valve Series AP1B2YP 7C, 14C, 21C, 35C Features Analog Relief Valve regulates pressure proportionally to the solenoid current Direct acting poppet design One piece cartridge housing ensures internal concentricity : Waterproof, hermetically sealed, requires no O Rings; Symmetrical coil can be reversed without affecting performance. s & Specifications Rated 7C 5.3 LPM (1.4 GPM) (At 7 PSI P) 14C 3.4 LPM (.9 GPM) 21C 3. LPM (.8 GPM) 35C 1.3 LPM (.35 GPM) Max. At 7C 7 Bar (1 PSI) Port 75% 14C 14 Bar (2 PSI) Input Current 21C 21 Bar (3 PSI) 35C 35 Bar (5 PSI) 5% 2 Hz PWM Cracking 7C.7 Bar (1 PSI) 14C.14 Bar (2 PSI) 21C.21 Bar (3 PSI) 35C.35 Bar (4 PSI) Cartridge Material Operating Temp. Range/Seals Fluid Compatibility/ Viscosity All parts steel. All operating parts hardened steel. -4 C to C (Nitrile) (-4 F to +2 F) C to C (Fluorocarbon) (-25 F to +25 F) Mineral-based or synthetic with lubricating properties at viscosities of 45 to 2 SSU (6 to 42 cst) Filtration ISO Code 16/13, SAE Class 4 or better Approx. Weight Cavity.6 kg (.14 lbs.) 2G (See Section for more details) Performance Curves PWM Current Regulator Recommended Drop vs. Drop ( P) vs. Input Signal (Current) PSI Bar PSI Bar LPM GPM (Q) Measured at De-energized coil Hydraulic Oil 15 1 F (32 cst) Hydraulic Oil 15 1 F (32 cst) Measured at coil stabilized temperature and nominal flow Current (%)

9 Catalog HY15-352/US s & Information Dimensions Millimeters (Inches) Relief Valve Series AP1B2YP 7C, 14C, 21C, 35C 75.7 (2.98) 39.6 (1.56) 17.9 (.7) PAT.XXXXXXX MADEINU.S.A. XXV XXW CCX XXX H 5/8 Hex. 4.1 Nm (3 lb. ft.) See Super 1/2" I.D. Information For Terminal Connectors 3/4 Hex. 24 Nm (18 lb. ft.) 5/8-18 UNF 62.7 (2.47) 19.8 (.78) 33.8 (1.33) 12.7 (.5) NOTE: Requires 2G Cavity Ordering Information AP1B2YP THIRD-ANG PROJECTION 8 Size Relief Valve Style Code Style (Maximum Relief ) 7C 7 Bar (1 PSI) 14C 14 Bar (2 PSI) 21C 21 Bar (3 PSI) 35C 35 Bar (5 PSI) Custom pressure setting available. Consult factory. Seals Type Code Seals / Kit No. N Nitrile / Buna-N (Std.) (SK3129N-1) V Fluorocarbon / (SK3129V-1) E Ethylene Propylene Voltage Termination Code Type Omit Without SP Super - 19 Watts Code Voltage Omit Without D12 12 V D24 24 V Code Termination Omit Without D DIN Plug Face A Amp Jr. Timer* L Dual Lead Wire* LS Sealed Lead Wire* H Molded Deutsch* See Super 1/2 I.D. * Only Order Bodies Separately LB1 Line Body Porting Body Material Code Porting Code Body Material 324 1/4 SAE A Aluminum 325 1/4 BSP S Steel 8

10 Catalog HY15-352/US Information General Description Relief Valve. Increasing With Increasing Current. For additional information see Tips on pages 1-6. Features Analog Relief Valve regulates pressure proportionally to the solenoid current Direct acting poppet design One piece cartridge housing ensures internal concentricity : Waterproof, hermetically sealed, requires no O Rings; Symmetrical coil can be reversed without affecting performance. NOTE: This valve will be available January 1, 211. Relief Valve Series AP2B2YP 7C, 14C, 21C, 35C s & Specifications Rated 7C 5.3 LPM (1.4 GPM) (At 7 PSI P) 14C 3.4 LPM (.9 GPM) 21C 3. LPM (.8 GPM) 35C 1.3 LPM (.35 GPM) Max. At 7C 7 Bar (1 PSI) Port 75% 14C 14 Bar (2 PSI) Input Current 21C 21 Bar (3 PSI) 35C 35 Bar (5 PSI) 5% 2 Hz PWM Cracking 7C.7 Bar (1 PSI) 14C.14 Bar (2 PSI) 21C.21 Bar (3 PSI) 35C.35 Bar (4 PSI) Cartridge Material Operating Temp. Range/Seals Fluid Compatibility/ Viscosity All parts steel. All operating parts hardened steel. -4 C to C (Nitrile) (-4 F to +2 F) C to C (Fluorocarbon) (-25 F to +25 F) Mineral-based or synthetic with lubricating properties at viscosities of 45 to 2 SSU (6 to 42 cst) Filtration ISO Code 16/13, SAE Class 4 or better Approx. Weight.6 kg (.14 lbs.) Cavity C8-2 (See Section for more details) Performance Curves PWM Current Regulator Recommended Drop vs. Drop ( P) vs. Input Signal (Current) PSI Bar PSI Bar LPM GPM (Q) Measured at De-energized coil Hydraulic Oil 15 1 F (32 cst) Hydraulic Oil 15 1 F (32 cst) Measured at coil stabilized temperature and nominal flow Current (%)

11 Catalog HY15-352/US Information Dimensions Millimeters (Inches) Relief Valve Series AP2B2YP 7C, 14C, 21C, 35C 85.8 (3.38) 39.5 (1.56) PAT.XXXXXXX MADEINU.S.A. XXV XXW CCX XXX H 5/8 Hex. 4.1 Nm (3 lb. ft.) See Super 1/2" I.D. Information For Terminal Connectors 7/8 Hex. 3 Nm (22 lb. ft.) 62.7 (2.47) 19.8 (.78) 33.8 (1.33) 27.8 (1.1) 3/4-16 UNF-2A Thread Ø12.6 (.5) s & Ordering Information AP2B2YP 8 Size Relief Valve Code Style (Maximum Relief ) 7C 7 Bar (1 PSI) 14C 14 Bar (2 PSI) 21C 21 Bar (3 PSI) 35C 35 Bar (5 PSI) Style Custom pressure setting available. Consult factory. Seals Type Code Seals / Kit No. Omit D -Ring / (SK8-2) N Nitrile / Buna-N (Std.) (SK8-2N) V Fluorocarbon / (SK8-2V) Code Type Omit Without SP Super - 19 Watts Voltage Termination Code Voltage Omit Without D12 12 V D24 24 V Code Termination Omit Without D DIN Plug Face A Amp Jr. Timer* L Dual Lead Wire* LS Sealed Lead Wire* H Molded Deutsch* See Super 1/2 I.D. * Only Body Material Port Size Code Port Size Body Part No. Omit Cartridge Only 4T SAE-4 (B8-2-*4T) 6T SAE-6 (B8-2-*6T) 6B 3/8 BSPG (B8-2-*6B) THIRD-ANG PROJECTION NOTE: This valve will be available January 1, 211. Code Body Material Omit Steel A Aluminum * Add A for aluminum, omit for steel. 1

12 Catalog HY15-352/US Information General Description Relief Valve. Increasing With Increasing Current. For additional information see Tips on pages 1-6. Features Pilot operated spool-type design fits industry common cavity (1-2) Relieving pressure output is proportional to current input Precise setting of factory preset pressure in energized mode One piece cartridge housing ensures internal concentricity : Waterproof, hermetically sealed, requires no O Rings; Symmetrical coil can be reversed without affecting performance. Relief Valve Series AP4G2YP 1C, 21C, 35C s & Specifications Rated (At 3 PSI P) When is Fully De-Energized 95 LPM (25 GPM) Factory Set Relief 1C 13 Bar (15 PSI) When 21C 21 Bar (3 PSI) De-Energized 35C 35 Bar (5 PSI) Measured at 45 LPM (12 GPM) < 7% 25 Hz PWM of Maximum Setting Response Time At To Unload 1ms 75% of Nominal To Load Voltage Change 1C 45 ms (Measured To 9% 21C 6 ms of Press. Change) 35C 8 ms Cartridge Material Operating Temp. Range/Seals Fluid Compatibility/ Viscosity All parts steel. All operating parts hardened steel. -4 C to C (Nitrile) (-4 F to +2 F) C to C (Fluorocarbon) (-25 F to +25 F) Mineral-based or synthetic with lubricating properties at viscosities of 45 to 2 SSU (6 to 42 cst) Filtration ISO Code 16/13, SAE Class 4 or better Approx. Weight.14 kg (.31 lbs.) Cavity C1-2 (See Section for more details) Performance Curves PWM Current Regulator Recommended Relief Performance Drop ( P) PSI Bar LPM GPM (Q) vs. Input Current PSI Bar V 24V Hydraulic Oil 15 1 F (32 cst) Fully Energized De-Energized Hydraulic Oil 15 1 F (32 cst) Measured at coil stabilized temperature and nominal flow Current, Amp

13 Catalog HY15-352/US Information Dimensions Millimeters (Inches) Relief Valve Series AP4G2YP 1C, 21C, 35C 97.6 (3.84) 39.6 (1.56) 1. (.4) 31.8 (1.25) PAT.XXXXXXX MADEINU.S.A. XXV XXW CCX XXX H 5/8 Hex. 4.1 Nm (3 lb. ft.) See Super 1/2" I.D. Information For Terminal Connectors 1 Hex. 34 Nm (25 lb. ft.) 7/8-14 UNF 62.7 (2.47) 19.8 (.78) 33.8 (1.33) s & 15.8 (.62) Ordering Information AP4G2YP THIRD-ANG PROJECTION 1 Size Relief Valve Code Style (Maximum Relief ) 1C 14 Bar (15 PSI) 21C 21 Bar (3 PSI) 35C 35 Bar (5 PSI) Code Seals / Kit. No. N Nitrile / Buna-N (Std.) (SK353N-1) V Fluorocarbon / (SK353V-1) Style Custom pressure setting available. Consult factory. Seals Code Voltage Omit Without D12 12 V D24 24 V Type Code Type Omit Without SP Super - 19 Watts Voltage Termination Code Termination Omit Without D DIN Plug Face A Amp Jr. Timer* L Dual Lead Wire* LS Sealed Lead Wire* H Molded Deutsch* See Super 1/2 I.D. * Only Body Material Port Size Code Body Material Omit Steel A Aluminum Code Port Size Body Part No. Omit Cartridge Only 4P 1/4 NPTF (B1-2-*4P) 6P 3/8 NPTF (B1-2-*6P) 8P 1/2 NPTF (B1-2-*8P) 6T SAE-6 (B1-2-*6T) 8T SAE-8 (B1-2-*8T) T8T SAE-8 (B1-2-T8T) 6B 3/8 BSPG (B1-2-*6B) * Add A for aluminum, omit for steel. Steel body only. 12

14 Catalog HY15-352/US Information General Description Relief Valve. Decreasing With Increasing Current. For additional information see Tips on pages 1-6. Relief Valve Series AP1B2YR 7A, 14A, 21A, 35A Features Analog Relief Valve regulates pressure proportionally to the input solenoid current Direct acting poppet design One piece cartridge housing ensures internal concentricity : Waterproof, hermetically sealed, requires no O Rings; Symmetrical coil can be reversed without affecting performance. s & Specifications Rated 7A 5.3 LPM (1.4 GPM) (At 7 PSI P) 14A 3.4 LPM (.9 GPM) 21A 3. LPM (.8 GPM) 35A 1.9 LPM (.5 GPM) Factory Set Relief 7A 7 Bar (1 PSI) When 14A 14 Bar (2 PSI) De-Energized 21A 21 Bar (3 PSI) (±5% -Std. 35A 35 Bar (5 PSI) ±2% - Low Variation) < 1% 2 Hz PWM Cartridge Material Operating Temp. Range/Seals Fluid Compatibility/ Viscosity All parts steel. All operating parts hardened steel. -4 C to C (Nitrile) (-4 F to +2 F) C to C (Fluorocarbon) (-25 F to +25 F) Mineral-based or synthetic with lubricating properties at viscosities of 45 to 2 SSU (6 to 42 cst) Filtration ISO Code 16/13, SAE Class 4 or better Performance Curves PWM Current Regulator Recommended Relief Performance Relief PSI Bar Hydraulic Oil 15 1 F (32 cst) -35A -21A -14A -7A LPM GPM (Q) vs. Input Current PSI Bar Hydraulic Oil 15 1 F (32 cst) Measured at coil stabilized temperature and nominal flow Approx. Weight Cavity.9 kg (.19 lbs.) 2G (See Section for more details) Input Current (%)

15 Catalog HY15-352/US s & Information Dimensions Millimeters (Inches) Relief Valve Series AP1B2YR 7A, 14A, 21A, 35A 25.4 Dia (1.) Finger Tight 66.5 (2.62) 22. (.86) 84. (3.32) 5. (1.97) 26. (1.2) PAT.XXXXXXX MADEINU.S.A. XXV XXW CAX XXX H See Super 5/8" I.D. Information For Terminal Connectors 3/4 Hex. 15 Nm (11 lb. ft.) 5/8-18 UNF 36. (1.43) 12.7 (.5) NOTE: Requires 2G Cavity THIRD-ANG PROJECTION Ordering Information AP1B2YR 8 Size Relief Valve Style Code Style (Maximum Relief ) 7AL 7 Bar (1 PSI) 14AL 14 Bar (2 PSI) 21AL 21 Bar (3 PSI) 35AL 35 Bar (5 PSI) Custom pressure setting available. Consult factory. Seals Type Code Seals / Kit. No. N Nitrile / Buna-N (Std.) (SK3129N-1) V Fluorocarbon / (SK3129V-1) E Ethylene Propylene Voltage Termination Code Type Omit Without SP Super - 28 Watts Code Voltage Omit Without D12 12 V D24 24 V Code Termination Omit Without D DIN Plug Face A Amp Jr. Timer* L Dual Lead Wire* LS Sealed Lead Wire* H Molded Deutsch* See Super 5/8 I.D. * Only Order Bodies Separately LB1 Line Body Porting Body Material Code Porting Code Body Material 324 1/4 SAE A Aluminum 325 1/4 BSP S Steel 14

16 Catalog HY15-352/US Information General Description Relief Valve. Decreasing With Increasing Current. For additional information see Tips on pages 1-6. Relief Valve Series AP2B2YR 7A, 14A, 21A, 35A Features Analog Relief Valve regulates pressure proportionally to the input solenoid current Direct acting poppet design One piece cartridge housing ensures internal concentricity : Waterproof, hermetically sealed, requires no O Rings; Symmetrical coil can be reversed without affecting performance. s & Specifications Rated 7A 5.3 LPM (1.4 GPM) (At 7 PSI P) 14A 3.4 LPM (.9 GPM) 21A 3. LPM (.8 GPM) 35A 1.9 LPM (.5 GPM) Factory Set Relief 7A 7 Bar (1 PSI) When 14A 14 Bar (2 PSI) De-Energized 21A 21 Bar (3 PSI) (±5% -Std. 35A 35 Bar (5 PSI) ±2% - Low Variation) < 1% 2 Hz PWM Cartridge Material Operating Temp. Range/Seals Fluid Compatibility/ Viscosity All parts steel. All operating parts hardened steel. -4 C to C (Nitrile) (-4 F to +2 F) C to C (Fluorocarbon) (-25 F to +25 F) Mineral-based or synthetic with lubricating properties at viscosities of 45 to 2 SSU (6 to 42 cst) Filtration ISO Code 16/13, SAE Class 4 or better Performance Curves PWM Current Regulator Recommended Relief Performance Relief PSI Bar Hydraulic Oil 15 1 F (32 cst) -35A -21A -14A -7A LPM GPM (Q) vs. Input Current PSI Bar Hydraulic Oil 15 1 F (32 cst) Measured at coil stabilized temperature and nominal flow Approx. Weight.9 kg (.19 lbs.) Cavity C8-2 (See Section for more details) Input Current (%)

17 Catalog HY15-352/US Information Dimensions Millimeters (Inches) Relief Valve Series AP2B2YR 7A, 14A, 21A, 35A 25.4 Dia (1.) Finger Tight 66.5 (2.62) 22. (.86) 93.3 (3.67) 5. (1.97) PAT.XXXXXXX MADEINU.S.A. XXV XXW CAX XXX H See Super 5/8" I.D. Information For Terminal Connectors 36. (1.43) 34.2 (1.35) 3/4 Hex. 15 Nm (11 lb. ft.) 3/4-16 UNF s & Ordering Information AP2B2YR THIRD-ANG PROJECTION 8 Size Relief Valve Code Seals / Kit. No. N Nitrile / Buna-N (Std.) (SK36N-1) V Fluorocarbon / (SK36V-1) E Ethylene Propylene Style Code Style (Maximum Relief ) 7AL 7 Bar (1 PSI) 14AL 14 Bar (2 PSI) 21AL 21 Bar (3 PSI) 35AL 35 Bar (5 PSI) Custom pressure setting available. Consult factory. Seals Code Voltage Omit Without D12 12 V D24 24 V Type Code Type Omit Without SP Super - 28 Watts Voltage Termination Code Termination Omit Without D DIN Plug Face A Amp Jr. Timer* L Dual Lead Wire* LS Sealed Lead Wire* H Molded Deutsch* See Super 5/8 I.D. * Only Body Material Port Size Code Body Material Omit Steel A Aluminum Code Port Size Body Part No. Omit Cartridge Only 4P 1/4 NPTF (B8-2-*4P) 6P 3/8 NPTF (B8-2-*6P) 4T SAE-4 (B8-2-*4T) 6T SAE-6 (B8-2-*6T) 6B 3/8 BSPG (B8-2-*6B) * Add A for aluminum, omit for steel. 16

18 Catalog HY15-352/US Information General Description Relief Valve. Decreasing With Increasing Current. For additional information see Tips on pages 1-6. Relief Valve Series AP4G2YR 1C, 21C, 35C s & Features Pilot operated spool-type design Precise setting of factory preset pressure in de-energized mode One piece cartridge housing ensures internal concentricity : Waterproof, hermetically sealed, requires no O Rings; Symmetrical coil can be reversed without affecting performance. Specifications Rated (At 3 PSI P) When is Fully Energized 95 LPM (25 GPM) Factory Set Relief 1C 13 Bar (15 PSI) When 21C 21 Bar (3 PSI) De-Energized 35C 35 Bar (5 PSI) Measured at 45 LPM (12 GPM) < 7% 25 Hz PWM of Maximum Setting Response Time At To Unload 45ms 75% of Nominal To Load 25ms Voltage Change (Measured To 9% of Press. Change) Cartridge Material Operating Temp. Range/Seals Fluid Compatibility/ Viscosity All parts steel. All operating parts hardened steel. -4 C to C (Nitrile) (-4 F to +2 F) C to C (Fluorocarbon) (-25 F to +25 F) Mineral-based or synthetic with lubricating properties at viscosities of 45 to 2 SSU (6 to 42 cst) Filtration ISO Code 16/13, SAE Class 4 or better Approx. Weight.14 kg (.3 lbs.) Cavity C1-2 (See Section for more details) Performance Curves PWM Current Regulator Recommended Relief Performance Relief PSI Bar Hydraulic Oil 15 1 F (32 cst) De-Energized -1 Fully Energized 3 21 LPM GPM (Q) vs. Input Current PSI Bar Hydraulic Oil 15 1 F (32 cst) Input Current (%) 17

19 Catalog HY15-352/US Information Dimensions Millimeters (Inches) Relief Valve Series AP4G2YR 1C, 21C, 35C 3/4 Hex. 4.1 Nm (3 lb. ft.) 62.7 (2.47) 19.8 (.78) 89.7 (3.53) 39.6 (1.56) 1. (.4) PAT.XXXXXXX MADEINU.S.A. XXV XXW CCX XXX H See Super 1/2" I.D. Information For Terminal Connectors 33.8 (1.33) 1 Hex. 34 Nm (25 lb. ft.) 31.8 (1.25) s & 15.8 (.62) 7/8-14 UNF THIRD-ANG PROJECTION Ordering Information AP4G2YR 1 Size Relief Valve Code Seals / Kit. No. N Nitrile / Buna-N (Std.) (SK353N-1) V Fluorocarbon / (SK353V-1) Style Code Style (Maximum Relief ) 1C 14 Bar (15 PSI) 21C 21 Bar (3 PSI) 35C 35 Bar (5 PSI) Custom pressure setting available. Consult factory. Seals Code Voltage Omit Without D12 12 V D24 24 V Type Code Type Omit Without SP Super - 19 Watts Voltage Termination Code Termination Omit Without D DIN Plug Face A Amp Jr. Timer* L Dual Lead Wire* LS Sealed Lead Wire* H Molded Deutsch* See Super 1/2 I.D. * Only Body Material Port Size Code Body Material Omit Steel A Aluminum Code Port Size Body Part No. Omit Cartridge Only 4P 1/4 NPTF (B1-2-*4P) 6P 3/8 NPTF (B1-2-*6P) 8P 1/2 NPTF (B1-2-*8P) 6T SAE-6 (B1-2-*6T) 8T SAE-8 (B1-2-*8T) T8T SAE-8 (B1-2-T8T) 6B 3/8 BSPG (B1-2-*6B) * Add A for aluminum, omit for steel. Steel body only. 18

20 Catalog HY15-352/US Information General Description 3 Way, 2 Position, Reducing Valve. Bottom Cylinder Port. For additional information see Tips on pages 1-6. Reducing Valve Series GP13 s & Features Designed for pilot control of directional valves Low Hysteresis One piece cartridge housing ensures internal concentricity : Waterproof, hermetically sealed, requires no O Rings; Symmetrical coil can be reversed without affecting performance. Specifications Rated 1.9 LPM (.5 GPM) (At 7 PSI P) Max. Regulated 75% 17 Bar (25 PSI) Current High 22 Bar (32 PSI) Max. Input Press. 21 Bar (3 PSI) At Port 1 Max. Tank Press. 3 Bar (44 PSI) Max. Drainage 5 cc/min. When De-Energized In Regulating 2 cc/min. In Regulating Zone Zone At 68 Bar (1 PSI) Input 2% 2 Hz PWM Dead End t on = 3 ms Response Time t off = 1 ms At Step Signal To 75% of Nominal Voltage Cartridge Material All parts steel. All operating parts hardened steel. Operating Temp. -4 C to C (Nitrile) Range/Seals (-4 F to +2 F) C to C (Fluorocarbon) (-25 F to +25 F) Fluid Mineral-based or synthetic with Compatibility/ lubricating properties at viscosities Viscosity of 45 to 2 SSU (6 to 42 cst) Filtration ISO Code 16/13, SAE Class 4 or better Approx. Weight.8 kg (.17 lbs.) Cavity 54-1 (See Section for more details) Performance Curves PWM Current Regulator Recommended Port 1 vs. Input Current 2 1 PSI Bar PSI Bar Drop vs. PSI Bar LPM GPM Port 1 vs. Input Current V 24V V 24V Hydraulic Oil 15 1 F (32 cst) With 12 Hz PWM Hydraulic Oil 15 1 F (32 cst) With 12 Hz PWM Tank Inlet Reducing Hydraulic Oil 15 1 F (32 cst).6.3 AMP.8.4 AMP to 1 Energized to 3 De-Eenergized

21 Catalog HY15-352/US s & Information Dimensions Millimeters (Inches) Reducing Valve Series GP (3.36) 9.7 (.38) 12.4 (.49) 39.6 (1.56) 5.6 (.22) 27.8 (1.9) PAT.XXXXXXX MADEINU.S.A. XXV XXW CCX XXX H Override Finger Tight See Super 1/2" I.D. Information For Terminal Connectors 13/16 Hex. 27 Nm (2 lb. ft.) M18X (2.47) 19.8 (.78) 33.8 (1.33) 11.9 (.47) NOTE: Requires 54-1 Cavity Ordering Information GP1 3 THIRD-ANG PROJECTION 8 Size Valve Code Style 3 Standard ( SS ) 3 High ( SP ) Code Override Option Omit If No M.O. 1 Override Style Override Option Filter Screen Code Filter Screen Omit Not Required F 6 Mesh Screen on Inlet Port Code Seals / Kit No. N Nitrile / Buna-N (Std.) (SK3122N-1) V Fluorocarbon / (SK3122V-1) Seals Type Voltage Code Type Omit Without SS Super - 14 Watts SP Super - 19 Watts Code Voltage Omit Without D12 12 V D24 24 V Termination Code Termination Omit Without D DIN Plug Face A Amp Jr. Timer* L Dual Lead Wire* LS Sealed Lead Wire* H Molded Deutsch* See Super 1/2 I.D. * Only Order Bodies Separately LB1 Line Body Porting Body Material Code Porting Code Body Material 591 1/4 SAE A Aluminum S Steel 2

22 Catalog HY15-352/US Information General Description 3 Way, 2 Position, Reducing Valve. Side Cylinder Port. For additional information see Tips on pages 1-6. Reducing Valve Series GTP234 s & Features Minimal Hysteresis One piece cartridge housing ensures internal concentricity : Waterproof, hermetically sealed, requires no O Rings; Symmetrical coil can be reversed without affecting performance. Nonmagnetic spool and housing assembly Specifications Rated 19 LPM (5 GPM) (At 7 PSI P) Max. Regulated 2 12/17 Bar (18/24 75% 3 19/26 Bar (27/375 PSI) Current 5 31/4 Bar (45/58 PSI) (Using SP ) 6 41/51 Bar (6/74 PSI) 9 65/79 Bar (94/114 PSI) /145 Bar (165/21 PSI) Max. Input Press. 21 Bar (3 PSI) At Port 3 Max. Drainage 1 cc/min. When De-Energized In Regulating 75 cc/min. In Regulating Zone Zone At 21 Bar (3 PSI) Input 3.5% 1 Hz PWM Dead End 1 ms At Step Signal Response Time To 75% of Nominal Voltage Cartridge Material All parts steel. All operating parts hardened steel. Operating Temp. -4 C to C (Nitrile) Range/Seals (-4 F to +2 F) C to C (Fluorocarbon) (-25 F to +25 F) Fluid Mineral-based or synthetic with Compatibility/ lubricating properties at viscosities Viscosity of 45 to 2 SSU (6 to 42 cst) Filtration ISO Code 16/13, SAE Class 4 or better Approx. Weight.8 kg (.17 lbs.) Cavity C8-3 (See Section for more details) Inlet Reducing Tank Performance Curves PWM Current Regulator Recommended Drop vs. Drop Control PSI Bar Hydraulic Oil 15 1 F (32 cst) 3 to 2 2 to 1 LPM GPM Port 2 vs. Input Current PSI Bar V 12V.1.2 Hydraulic Oil 15 1 F (32 cst) With 1 Hz PWM Current Amps.5 1. GTP234 6 GTP234 3 GTP

23 Catalog HY15-352/US s & Information Dimensions Millimeters (Inches) Reducing Valve Series GTP (3.69) (.52) 39.6 (1.56) 5.59 (.22) 4.21 (1.58) PAT.XXXXXXX MADEINU.S.A. XXV XXW CCX XXX H Override (Infinite Control) 3/4 Hex. 4.1 Nm (3 lb. ft.) See Super 1/2" I.D. Information For Terminal Connectors 7/8 Hex. 27 Nm (2 lb. ft.) 3/4-16 UNF 62.7 (2.47) 19.8 (.78) 33.8 (1.33) 14.2 (.56) Ordering Information GTP234 8 Size Valve Code Override Option Not Required 5 Detented M.O. Style Code Style (Maximum Regulated Range - SP COIL) 2 12/17 Bar (18/24 PSI) 3 19/26 Bar (27/375 PSI) 5 31/4 Bar (45/58 PSI) 6 41/51 Bar (6/74 PSI) 9 65/79 Bar (94/114 PSI) /145 Bar (165/21 PSI) Override Option 1 Filter Screen Seals Code Filter Screen 1 6 Mesh Screen on Inlet Port Code Seals / Kit No. N Nitrile / Buna-N (Std.) (SK381N-1) V Fluorocarbon / (SK381V-1) Code Type Omit Without SS Super - 14 Watts SP Super - 19 Watts Type Voltage Code Voltage Omit Without D12 12 V D24 24 V Code Termination Omit Without D DIN Plug Face A Amp Jr. Timer* L Dual Lead Wire* LS Sealed Lead Wire* H Molded Deutsch* See Super 1/2 I.D. * Only Termination Body Material Port Size Code Body Material Omit Steel A Aluminum Code Port Size Body Part No. Omit Cartridge Only 4P 1/4 NPTF (B8-3-*4P) 4T SAE-4 (B8-3-*4T) 6T SAE-6 (B8-3-*6T) 6B 3/8 BSPG (B8-3-*6B) * Add A for aluminum, omit for steel. THIRD-ANG PROJECTION 22

24 Catalog HY15-352/US Information General Description 3 Way, 2 Position, Reducing Valve. Side Cylinder Port. For additional information see Tips on pages 1-6. Reducing Valve Series GTP434 s & Features Minimal Hysteresis One piece cartridge housing ensures internal concentricity : Waterproof, hermetically sealed, requires no O Rings; Symmetrical coil can be reversed without affecting performance. Nonmagnetic spool and housing assembly Specifications Rated 3 LPM (8 GPM) (At 7 PSI P) Max. Regulated 2 14/17 Bar (2/24 75% 3 21/27 Bar (3/39 PSI) Current 5 29/38 Bar (42/55 PSI) (Using SP ) 9 56/74 Bar (81/18 PSI) Max. Input Press. 21 Bar (3 PSI) At Port 3 Max. Drainage 25 cc/min. When De-Energized In Regulating 8 cc/min. In Regulating Zone Zone At 21 Bar (3 PSI) Input 3.5% 2 Hz PWM Dead End 4 ms At Step Signal Response Time To 75% of Nominal Voltage Cartridge Material All parts steel. All operating parts hardened steel. Operating Temp. -4 C to C (Nitrile) Range/Seals (-4 F to +2 F) C to C (Fluorocarbon) (-25 F to +25 F) Fluid Mineral-based or synthetic with Compatibility/ lubricating properties at viscosities Viscosity of 45 to 2 SSU (6 to 42 cst) Filtration ISO Code 16/13, SAE Class 4 or better Approx. Weight.13 kg (.28 lbs.) Cavity 3X (See Section for more details) Inlet Reducing Tank Performance Curves PWM Current Regulator Recommended Drop vs. Drop Control PSI Bar Hydraulic Oil 15 1 F (32 cst) to 1 3 to 2 LPM GPM Port 2 vs. Input Current PSI Bar V 12V Hydraulic Oil 15 1 F (32 cst) With 1 Hz PWM Current Amps GTP4 349 GTP4 345 GTP4 343 GTP

25 Catalog HY15-352/US Information Dimensions Millimeters (Inches) Reducing Valve Series GTP (.52) Override (Infinite Control) 66.5 (2.62) 22. (.86) 3/4 Hex. 4.1 Nm (3 lb. ft.) 36. (1.43) (4.44) 5. (1.97) 5.54 (.22) PAT.XXXXXXX MADEINU.S.A. XXV XXW CAX XXX H See Super 5/8" I.D. Information For Terminal Connectors 1 Hex. 3 Nm (22 lb. ft.) (1.92) 7/8-14 UNF 17.4 (.69) NOTE: Requires 3X Cavity THIRD-ANG PROJECTION Ordering Information GTP Size Valve Style Code Style (Maximum Regulated Range - SP ) 2 14/17 Bar (2/24 PSI) 3 21/27 Bar (3/39 PSI) 5 29/38 Bar (42/55 PSI) 9 56/74 Bar (81/18 PSI) Contact factory for other regulated pressure to 124 Bar (18 PSI) Order Bodies Separately LB1 Line Body Code Porting 553 1/2 SAE 554 3/8 BSP Porting Override Option Body Material Code Body Material A Aluminum S Steel Filter Screen Code Override Option Not Required 5 Detented M.O. Seals Code Filter Screen 1 6 Mesh Screen on Inlet Port Type Voltage Code Seals / Kit No. N Nitrile / Buna-N (Std.) (SK381N-1) V Fluorocarbon / (SK381V-1) Code Type Omit Without SS Super - 18 Watts SP Super - 28 Watts Termination Code Voltage Omit Without D12 12 V D24 24 V Code Termination Omit Without D DIN Plug Face A Amp Jr. Timer* L Dual Lead Wire* LS Sealed Lead Wire* H Molded Deutsch* See Super 5/8 I.D. * Only s & 24

26 Catalog HY15-352/US Information General Description Normally Closed Control Valve. For additional information see Tips on pages 1-6. N.C. Control Valve Series DF122C Features On-off type solenoids Low hysteresis PWM signal preferred override standard All external parts zinc plated In Specifications Performance Curves Out s & Rated 53 LPM (14 GPM) Valve Fully Open Maximum Inlet 21 Bar (3 PSI) Hysteresis 2 Hz PWM Cracking 2% - 3% of Input Signal (Dead band) Frequency 1-4 Hz (2 Hz Preferred) Maximum Control 12 V 24V Current 2.45A 1.23A Cartridge Material All parts steel. All operating parts hardened steel. Operating Temp. -4 C to C (Nitrile) Range/Seals (-4 F to +2 F) C to C (Fluorocarbon) (-25 F to +25 F) Fluid Mineral-based or synthetic with Compatibility/ lubricating properties at viscosities Viscosity of 45 to 2 SSU (6 to 42 cst) Filtration ISO Code 16/13, SAE Class 4 or better Approx. Weight.32 kg (.7 lbs.) Cavity C12-2 (See Section for more details) Form Tool Rougher None Finisher NFT12-2F Drop ( P) (Q) (Q) PSI Bar Drop 1% Control Current Hydraulic Oil 15 1 F (32 cst) LPM GPM (Q) vs. 1% Control Current Hydraulic Oil 15 1 F (32 cst) Bar PSI Inlet vs. Input Signal (Current) Hydraulic Oil 15 1 F (32 cst) Percent of Maximum Control Current

27 Catalog HY15-352/US s & Information Dimensions Millimeters (Inches) N.C. Control Valve Series DF122C 161. (6.33) 17 (.66) 56. (2.2) See DS 1" I.D. Information For Terminal Connectors Finger Tight 6. (2.35) 48. (1.9) 1-1/4" Hex. 29 Nm (21 lb. ft.) 41.3 (1.63) 1-1/16-12 UNF-2A Thread Ø 22.2 (.87) THIRD-ANG PROJECTION Ordering Information DF122C14 12 Size Normally Closed Control Valve Override Options Seals Voltage Wattage Termination Body Material Port Size Code Override Options Omit Push Type with Extended Rod Code Seals / Kit. No. Omit Nitrile / (SK12-2) V Fluorocarbon / (SK12-2V) Code Voltage Omit Cartridge without D12 12 V D24 24 V Code Wattage Omit Cartridge without H High Watt Code Termination Omit Cartridge without D DIN P Dual Spade W Dual Wire See DS 1 I.D. Code Body Material Omit Steel A Aluminum Code Port Size Body Part No. 12P 3/4 NTPF (B12-2-*12P) 8T SAE - 8 (B12-2-*8T) 12T SAE - 12 (B12-2-*12T) * Add A for aluminum, omit for steel. 26

28 s & Catalog HY15-352/US Information General Description Normally Closed Needle Valve. This valve is designed specifically for bleed off or unloading circuits. Back pressure will affect performance. For additional information see Tips on pages 1-6. Features On-off type solenoids Low hysteresis PWM signal preferred All external parts zinc plated Specifications Rated High Watt Valve Fully Open 15 LPM (4 GPM) Maximum Inlet 21 Bar (3 PSI) Leakage at 125 cc/min. (7.6 in 3 /min.) 15 SSU (32 cst) Hysteresis 2 Hz PWM Cracking 2% - 3% of Input Signal (Dead band) Frequency 1-4 Hz (2 Hz Preferred) Maximum Control 12 V 24V Current High Watt 2.45A 1.23A Cartridge Material All parts steel. All operating parts hardened steel. Operating Temp. -4 C to C (Nitrile) Range/Seals (-4 F to +2 F) C to C (Fluorocarbon) (-25 F to +25 F) Fluid Mineral-based or synthetic with Compatibility/ lubricating properties at viscosities Viscosity of 45 to 2 SSU (6 to 42 cst) Filtration ISO Code 16/13, SAE Class 4 or better Approx. Weight.34 kg (.75 lbs.) Cavity C16-2 (See Section for more details) Form Tool Rougher None Finisher NFT16-2F N.C. Needle Valve Series DF161C Performance Curves Drop ( P) (Q) PSI Bar Outlet Hydraulic Oil 15 1 F (32 cst) vs. Input Signal (Current) Hydraulic Oil 15 1 F (32 cst) Inlet Drop 1% Current LPM GPM (Q) High 34.5 Bar (5 PSI) A Current in Amps High Watt High 27 Bar (3 PSI) 27

29 Catalog HY15-352/US Information Dimensions Millimeters (Inches) N.C. Needle Valve Series DF161C 56. (2.2) 4.1 Nm (3 lb. ft.) See DS 1" I.D. Information For Terminal Connectors 59.8 (2.35) 48.1 (1.9) (5.38) 1-1/2" Hex. 54 Nm (4 lb. ft.) 44.4 (1.75) 1-5/16-12 UN-2A Thread Inlet Ø 28.5 (1.12) Outlet THIRD-ANG PROJECTION s & Ordering Information DF161C4 16 Size Normally Closed Control Valve Seals Voltage Termination Body Material Port Size Code Seals / Kit. No. Omit Nitrile / (SK16-2) V Fluorocarbon / (SK16-2V) Code Voltage Omit Cartridge without D12 12 V D24 24 V Code Termination Omit Cartridge without D DIN P Dual Spade W Dual Wire See DS 1 I.D Code Body Material Omit Steel A Aluminum Code Port Size Body Part No. 12P 3/4 NTPF (B16-2-*12P) 16P 1 NTPF (B16-2-*16P) 8T SAE - 8 (B16-2-*8T) 12T SAE - 12 (B16-2-*12T) 16T SAE - 16 (B16-2-*16T) 12B 3/4 BSPG (B B) 16B 1 BSPG (B16-2-*16B) * Add A for aluminum, omit for steel. Steel body only. 28

30 Catalog HY15-352/US Information General Description Normally Closed Needle Valve. This valve is designed specifically for bleed off or unloading circuits. Back pressure will affect performance. For additional information see Tips on pages 1-6. Features On-off type solenoids Low hysteresis PWM signal preferred All external parts zinc plated N.C. Needle Valve Series DF21C Inlet Outlet s & Specifications Rated Low Watt 18 LPM (48 GPM) Valve Fully Open High Watt 227 LPM (6 GPM) Maximum Inlet 21 Bar (3 PSI) Leakage at 125 cc/min. (7.6 in 3 /min.) 15 SSU (32 cst) Hysteresis 2 Hz PWM Cracking 2% - 3% of Input Signal (Dead band) Frequency 1-4 Hz (2 Hz Preferred) Maximum Control 12 V 24V Current Low Watt 1.75A.91A High Watt 2.45A 1.23A Cartridge Material All parts steel. All operating parts hardened steel. Operating Temp. -4 C to C (Nitrile) Range/Seals (-4 F to +2 F) C to C (Fluorocarbon) (-25 F to +25 F) Fluid Mineral-based or synthetic with Compatibility/ lubricating properties at viscosities Viscosity of 45 to 2 SSU (6 to 42 cst) Filtration ISO Code 16/13, SAE Class 4 or better Approx. Weight.34 kg (.75 lbs.) Cavity C2-2 (See Section for more details) Form Tool Rougher None Finisher NFT2-2F Performance Curves Drop ( P) (Q) PSI Bar Drop 1% Current Hydraulic Oil 15 1 F (32 cst) vs. Input Signal (Current) Hydraulic Oil 15 1 F (32 cst) Low 27 Bar (3 PSI) Low Watt 2 75 Low 34.5 Bar (5 PSI) 1 38 High 34.5 Bar (5 PSI) A Current in Amps High Watt LPM GPM (Q) High 27 Bar (3 PSI) 29

31 Catalog HY15-352/US s & Information Dimensions Millimeters (Inches) N.C. Needle Valve Series DF21C 56. (2.2) 4.1 Nm (3 lb. ft.) See DS 1" I.D. Information For Terminal Connectors 6.5 (2.38) 48.3 (1.9) (5.6) 1-7/8" Hex. 113 Nm (83 lb. ft.) 55.1 (2.17) 1 5/8-12 UN-2A Thread Inlet Ø 36.8 (1.45) Outlet THIRD-ANG PROJECTION Ordering Information DF21C6 2 Size Normally Closed Control Valve Seals Voltage Wattage Termination Body Material Port Size Code Seals / Kit. No. Omit Nitrile / (SK2-2) V Fluorocarbon / (SK2-2V) Code Voltage Omit Cartridge without D12 12 V D24 24 V Code Wattage Omit Cartridge without L Low Watt H High Watt Code Termination Omit Cartridge without D DIN P Dual Spade W Dual Wire See DS 1 I.D. Code Body Material Omit Steel A Aluminum Code Port Size Body Part No. 2T SAE - 2 (B2-2-*2T) 2B 1-1/4 BSPG (B2-2-*2B) * Add A for aluminum, omit for steel. 3

32 s & Catalog HY15-352/US Information General Description 2 Way, Normally Closed, Regulator Valve. Partially Compensated. For additional information see Tips on pages 1-6. Features Analog Partially Compensated Regulator regulates flow proportionally to the input solenoid current. A low cost valve designed to be used in applications where fine pressure compensation is not required. One piece cartridge housing ensures internal concentricity : Waterproof, hermetically sealed, requires no O Rings; Symmetrical coil can be reversed without affecting performance. Nonmagnetic spool and housing assembly Factory-adjusted low variation option (Model L ) is available for applications where low variation of flow from valve to valve is essential at a given current or when an external pressure compensator is used. Specifications Standard ( SS ) 21 Bar (3 PSI) 2 to LPM (3.5 GPM) 1 to LPM (2.5 GPM) High ( SP ) 2 to LPM (6. GPM) 1 to LPM (4. GPM) Preferable Input Port 1 Port For Best Hysteresis <1% 1 Hz PWM Cracking 25% of Input Current Variation of Standard 35% of Rated Up To ±2% Of Rated Current & Constant Model L P Maintained By ±7% Of Rated Compensator Cartridge Material All parts steel. All operating parts hardened steel. Operating Temp. -4 C to C (Nitrile) Range/Seals (-4 F to +2 F) C to C (Fluorocarbon) (-25 F to +25 F) Fluid Mineral-based or synthetic with Compatibility/ lubricating properties at viscosities Viscosity of 45 to 2 SSU (6 to 42 cst) Filtration ISO Code 16/13, SAE Class 4 or better Approx. Weight.8 kg (.17 lbs.) Cavity 2X (See Section for more details) Regulator Valve Series HP2C 21 Performance Curves PWM Current Regulator Recommended vs. Input Current Regulation (Measured at 75% of Rated Current) Bar PSI 35 5 Hydraulic Oil 15 1 F (32 cst) Input Current (%) Hydraulic Oil 15 1 F (32 cst) 1 to 2 ('SP' ) 2 to 1 ('SP' ) 2 to 1 ('SP' ) 2 to 1 ('SS' ) 1 to 2 ('SS' ) to 1 ('SS' ) 1 to 2 ('SS' ) 8 1 to 2 ('SP' )

33 Catalog HY15-352/US Information Dimensions Millimeters (Inches) Regulator Valve Series HP2C (.52) Override (Infinite Control) 62.7 (2.47) 19.8 (.78) 82.4 (3.23) 39.6 (1.56) 5.59 (.22) PAT.XXXXXXX MADEINU.S.A. XXV XXW CCX XXX H 3/4 Hex. 4.1 Nm (3 lb. ft.) See Super 1/2" I.D. Information For Terminal Connectors 7/8 Hex. 2 Nm (27 lb. ft.) 33.8 (1.33) 28.5 (1.12) 3/4-16 UNF 15.9 (.63) NOTE: Requires 2X Cavity Ordering Information HP2C 21 THIRD-ANG PROJECTION 8 Size Valve Style Code Style (Maximum Regulated ) 21 Standard ( SS ) 13.3 LPM (3.5 GPM) 21 High ( SP ) 22.8 LPM (6. GPM) Code Override Option Not Required 5 Detented M.O. (Infinite Control) Order Bodies Separately LB1 Line Body Code Porting 513 3/8 SAE 515 1/4 BSP Porting Override Option Body Material Filter Screen Code Filter Screen Not Available Code Seals / Kit No. N Nitrile / Buna-N (Std.) (SK376N-1) V Fluorocarbon / (SK376V-1) Code Body Material A Aluminum S Steel Seals Variation Type Voltage Code Variation Omit Standard Up to ±2% of Rated L Low Variation (±7% of Rated ) Code Type Omit Without SS Super - 14 Watts SP Super - 19 Watts Termination Code Voltage Omit Without D12 12 V D24 24 V Code Termination Omit Without D DIN Plug Face A Amp Jr. Timer* L Dual Lead Wire* LS Sealed Lead Wire* H Molded Deutsch* See Super 1/2 I.D. * Only s & 32

34 Catalog HY15-352/US Information General Description 2 Way, Normally Closed, Regulator Valve. Compensated. For additional information see Tips on pages 1-6. Features One piece cartridge housing ensures internal concentricity : Waterproof, hermetically sealed, requires no O Rings; Symmetrical coil can be reversed without affecting performance. Nonmagnetic spool and housing assembly Factory-adjusted low variation option (Model L ) is available for applications where low variation of flow from valve to valve is essential at a given current. Regulator Valve Series JP2C 2, 21 Port Is Not Used s & Specifications Rated LPM (2 GPM) Low ( SS ) LPM (4 GPM) Standard ( SS ) LPM (6 GPM) High ( SP ) Maximum Input 21 Bar (3 PSI) At Port 2 Minimum Bar (15 PSI) Low Differential Bar (2 PSI) Standard Bar (3 PSI) High Maximum Internal 57 cc (35 cu. in.) 21 Bar (3 PSI) <1% (Low and Standard) 1 Hz PWM <3% (High ) Cracking 25% of Input Signal Variation of Standard 35% of Rated Current Up To ±2% Of Rated Model L ±7% Of Rated Cartridge Material All parts steel. All operating parts hardened steel. Operating Temp. -4 C to C (Nitrile) Range/Seals (-4 F to +2 F) C to C (Fluorocarbon) (-25 F to +25 F) Fluid Mineral-based or synthetic with Compatibility/ lubricating properties at viscosities Viscosity of 45 to 2 SSU (6 to 42 cst) Filtration ISO Code 16/13, SAE Class 4 or better Approx. Weight.8 kg (.17 lbs.) Cavity C8-3 (See Section for more details) Performance Curves PWM Current Regulator Recommended vs. Input Current Drop vs. PSI Bar Hydraulic Oil 15 1 F (32 cst) Bar PSI 6.9 LPM GPM 35 5 Measured when valve is fully 75% of rated current Hydraulic Oil 15 1 F (32 cst) 7 1 JP2C 2 ('SS' ) JP2C 21 ('SP' ) Input Current (%) Regulation (Measured 75% of Rated Current) Hydraulic Oil 15 1 F (32 cst) JP2C 21 ('SS' ) JP2C 21 ('SS' ) 8 JP2C 21 ('SP' ) JP2C 21 ('SS' ) JP2C 2 ('SS' ) JP2C 2 ('SS' ) JP2C 21 ('SP' )

35 Catalog HY15-352/US s & Information Dimensions Millimeters (Inches) Regulator Valve Series JP2C 2, (.52) Override (Infinite Control) 62.7 (2.47) 19.8 (.78) 39.6 (1.56) 5.54 (.22) PAT.XXXXXXX MADEINU.S.A. XXV XXW CCX XXX H 3/4 Hex. 4.1 Nm (3 lb. ft.) See Super 1/2" I.D. Information For Terminal Connectors 33.8 (1.33) 96.4 (3.78) 42.5 (1.67) 7/8 Hex. 27 Nm (2 lb. ft.) 3/4-16 UNF 14.2 (.56) THIRD-ANG PROJECTION Ordering Information JP2C 8 Size Valve Style Code Style (Maximum Regulated ) 2 Low ( SS ) 7.5 LPM (2 GPM) 21 Standard ( SS ) 15 LPM (4 GPM) 21 High ( SP ) 23 LPM (6 GPM) Code Override Option Not Required 5 Detented M.O. (Infinite Control) Code Filter Screen Not Available 1 6 Mesh Screen on Port 2 Override Option Filter Screen Seals Code Seals / Kit No. N Nitrile / Buna-N (Std.) (SK315N-1) V Fluorocarbon / (SK315V-1) Code Variation Omit Standard Up to ±2% of Rated L Low Variation (±7% of Rated ) Code Type Omit Without SS Super - 14 Watts SP Super - 19 Watts Variation Type Code Voltage Omit Without D12 12 V D24 24 V Code Termination Omit Without D DIN Plug Face A Amp Jr. Timer* L Dual Lead Wire* LS Sealed Lead Wire* H Molded Deutsch* See Super 1/2 I.D. * Only Voltage Termination Body Material Code Body Material Omit Steel A Aluminum Port Size Code Port Size Body Part No. Omit Cartridge Only 4P 1/4 NPTF (B8-3-*4P) 4T SAE-4 (B8-3-*4T) 6T SAE-6 (B8-3-*6T) 6B 3/8 BSPG (B8-3-*6B) * Add A for aluminum, omit for steel. 34

36 s & Catalog HY15-352/US Information General Description 2 Way, Normally Closed, Regulator Valve. Partially Compensated. For additional information see Tips on pages 1-6. Features Analog Partially Compensated Regulator regulates flow proportionally to the input solenoid current. A low cost valve designed to be used in applications where fine pressure compensation is not required. One piece cartridge housing ensures internal concentricity : Waterproof, hermetically sealed, requires no O Rings; Symmetrical coil can be reversed without affecting performance. Nonmagnetic spool and housing assembly Factory-adjusted low variation option (Model L ) is available for applications where low variation of flow from valve to valve is essential at a given current or when an external pressure compensator is used. Specifications Rated Standard ( SS ) 2 to 3 LPM (8 GPM) 21 Bar (3 PSI) High ( SP ) 36 LPM (9.5 GPM) Preferable Input Port 1 Port For Best Hysteresis <1% 1 Hz PWM Cracking 21% of Rated Current (Standard) 17% of Rated Current (High ) Variation of Standard 35% of Rated Up To ±5% Of Rated Current & Constant Model L P Maintained By ±2% Of Rated Compensator Cartridge Material All parts steel. All operating parts hardened steel. Operating Temp. -4 C to C (Nitrile) Range/Seals (-4 F to +2 F) C to C (Fluorocarbon) (-25 F to +25 F) Fluid Mineral-based or synthetic with Compatibility/ lubricating properties at viscosities Viscosity of 45 to 2 SSU (6 to 42 cst) Filtration ISO Code 16/13, SAE Class 4 or better Approx. Weight.12 kg (.26 lbs.) Cavity C1-2 (See Section for more details) Regulator Valve Series HP4C 21 Performance Curves PWM Current Regulator Recommended vs. Input Current Regulation Bar PSI 35 5 Hydraulic Oil 15 1 F (32 cst) Input Current (%) 'SP' 'SS' Hydraulic Oil 15 1 F (32 cst) Measured 75% of rated current with 'SP' to 1 1 to

37 Catalog HY15-352/US s & Information Dimensions Millimeters (Inches) Regulator Valve Series HP4C (.54) 5. (1.97) 7.88 (.31) 5.6 (.22) 4. Stroke (.16) PAT.XXXXXXX MADEINU.S.A. XXV XXW CAX XXX H Override (Infinite Control) 3/4 Hex. 4.1 Nm (3 lb. ft.) See Super 5/8" I.D. Information For Terminal Connectors 66.5 (2.62) 22. (.86) 36. (1.43) 96.5 (3.8) 33.3 (1.31) 1 Hex. 3 Nm (22 lb. ft.) 7/8-14 UNF 15.8 (.62) Ordering Information HP4C 21 THIRD-ANG PROJECTION 1 Size Valve Code Filter Screen Not Available Style Code Style (Maximum Regulated ) 21 Standard ( SS ) 3 LPM (8 GPM) 21 High ( SP ) 36 LPM (9.5 GPM) Code Override Option Not Required 5 Detented M.O. (Infinite Control) Override Option Filter Screen Seals Code Seals / Kit No. N Nitrile / Buna-N (Std.) (SK353N-1) V Fluorocarbon / (SK353V-1) Code Variation Omit Standard Up to ±5% of Current L Low Variation (±2% of Current ) Code Type Omit Without SS Super - 18 Watts SP Super - 28 Watts Opening Point Variation Code Voltage Omit Without D12 12 V D24 24 V Type Code Termination Omit Without D DIN Plug Face A Amp Jr. Timer* L Dual Lead Wire* LS Sealed Lead Wire* H Molded Deutsch* See Super 5/8 I.D. * Only Voltage Termination Code Body Material Omit Steel A Aluminum Body Material Code Port Size Body Part No. Omit Cartridge Only 4P 1/4 NPTF (B1-2-*4P) 6P 3/8 NPTF (B1-2-*6P) 8P 1/2 NPTF (B1-2-*8P) 6T SAE-6 (B1-2-*6T) 8T SAE-8 (B1-2-*8T) T8T SAE-8 (B1-2-T8T) 6B 3/8 BSPG (B1-2-*6B) * Add A for aluminum, omit for steel. Steel body only. Port Size 36

38 Catalog HY15-352/US Information General Description 2 Way, Normally Closed, Regulator Valve. Compensated. For additional information see Tips on pages 1-6. Regulator Valve Series JP4C 21 Features One piece cartridge housing ensures internal concentricity : Waterproof, hermetically sealed, requires no O Rings; Symmetrical coil can be reversed without affecting performance. Nonmagnetic spool and housing assembly Factory-adjusted low variation option (Model L ) is available for applications where low variation of flow from valve to valve is essential at a given current. Port Is Not Used s & Specifications Rated 21 3 LPM (8 GPM) Standard ( SS ) LPM (9.5 GPM) High ( SP ) Maximum Input 21 Bar (3 PSI) At Port 2 Minimum Bar (2 PSI) Standard Differential Bar (3 PSI) High Maximum Internal 78 cc (46 cu. in.) 21 Bar (3 PSI) 7% 1 Hz PWM Cracking 25% of Input Signal Variation of Standard 35% of Rated Current Up To ±2% Of Rated Model L ±7% Of Rated Cartridge Material All parts steel. All operating parts hardened steel. Operating Temp. -4 C to C (Nitrile) Range/Seals (-4 F to +2 F) C to C (Fluorocarbon) (-25 F to +25 F) Fluid Mineral-based or synthetic with Compatibility/ lubricating properties at viscosities Viscosity of 45 to 2 SSU (6 to 42 cst) Filtration ISO Code 16/13, SAE Class 4 or better Approx. Weight.13 kg (.28 lbs.) Cavity 3X (See Section for more details) Performance Curves PWM Current Regulator Recommended vs. Input Signal Drop vs. PSI Bar Hydraulic Oil 15 1 F (32 cst) GPM LPM LPM GPM 35 5 Measured when valve is fully 75% of rated current Hydraulic Oil 15 1 F (32 cst) Input Current (%) 'SS' "SP" "SS" Regulation (Measured 75% of Rated Current) Bar PSI 'SP' Hydraulic Oil 15 1 F (32 cst) JP4C 21 ("SP" ) JP4C 21 ("SS" )

39 Catalog HY15-352/US Information Dimensions Millimeters (Inches) Regulator Valve Series JP4C (.52) Override (Infinite Control) 66.5 (2.62) 22. (.86) 3/4 Hex. 4.1 Nm (3 lb. ft.) 36. (1.43) (4.55) 5. (1.97) 5.51 (.22) (2.4) PAT.XXXXXXX MADEINU.S.A. XXV XXW CAX XXX H See Super 5/8" I.D. Information For Terminal Connectors 1 Hex. 3 Nm (22 lb. ft.) 7/8-14 UNF 17.4 (.68) NOTE: Requires 3X Cavity THIRD-ANG PROJECTION Ordering Information JP4C 21 1 Size Valve Style Code Style (Maximum Regulated ) 21 Standard ( SS ) 3 LPM (8 GPM) 21 High ( SP ) 36 LPM 9.5 GPM) Code Override Option Not Required 5 Detented M.O. (Infinite Control) Order Bodies Separately LB1 Line Body Code Porting 553 1/2 SAE 554 3/8 BSP Porting Override Option Body Material Filter Screen Code Filter Screen Not Required 1 6 Mesh Screen on Port 2 Code Seals / Kit No. N Nitrile / Buna-N (Std.) (SK316N-1) V Fluorocarbon / (SK316V-1) Code Body Material A Aluminum S Steel Seals Variation Type Voltage Code Variation Omit Standard Up to ±2% of Rated L Low Variation (±7% of Rated ) Code Type Omit Without SS Super - 18 Watts SP Super - 28 Watts Termination Code Voltage Omit Without D12 12 V D24 24 V Code Termination Omit Without D DIN Plug Face A Amp Jr. Timer* L Dual Lead Wire* LS Sealed Lead Wire* H Molded Deutsch* See Super 5/8 I.D. * Only s & 38

40 Catalog HY15-352/US Information Regulator Valve Series DFA125C21 General Description 2 Way, Normally Closed, Regulator Valve. Compensated. For additional information see Tips on pages 1-6. Features One piece cartridge housing ensures internal concentricity : Waterproof, hermetically sealed, requires no O Rings; Symmetrical coil can be reversed without affecting performance. s & NOTE: This valve will be available January 1, 211. Specifications 75% of Rated Current Maximum Input At Port 2 Minimum Differential Maximum Internal Leakage >15% 1 Hz PWM Cartridge Material Operating Temp. Range/Seals Fluid Compatibility/ Viscosity 56.8 LPM (15 GPM) Requires ( SP ) 21 Bar (3 PSI) 2.7 Bar (3 PSI) 568 cc (35 cu. 21 Bar (3 PSI) All parts steel. All operating parts hardened steel. -4 C to C (Nitrile) (-4 F to +2 F) C to C (Fluorocarbon) (-25 F to +25 F) Mineral-based or synthetic with lubricating properties at viscosities of 45 to 2 SSU (6 to 42 cst) Filtration ISO Code 16/13, SAE Class 4 or better Approx. Weight Cavity.4 kg (.89 lbs.) C12-3L (See Section for more details) Performance Curves PWM Current Regulator Recommended vs. Input Current Differential PSI Bar Port Is Not Used Compensation of Regulated Bar PSI Hydraulic Oil 15 1 F (32 cst) Hydraulic Oil 15 1 F (32 cst) 25 5 Input Current (%) Drop vs. (Through cartridge only) Hydraulic Oil 15 1 F (32 cst) % of Rated Current Load LPM GPM (Q)

41 XXV XXW CAX XXX H PAT.XXXXXXX MADEINU.S.A. Catalog HY15-352/US Information Dimensions Millimeters (Inches) 15.7 (.62) 8.7 (.34) 2.5 (.1) Regulator Valve Series DFA125C21 Override (Infinite Control) 66.5 (2.62) 22. (.86) Finger Tight to 4.1 Nm (3 lb. ft.) Max. 36. (1.43) 99.5 (3.92) 5. (1.97) See Super 5/8" I.D. Information For Terminal Connectors (6.92) 76.2 (3.) 4.8 (.19) 19.1 (.75) 1-1/4" Hex. 74 Nm (55 lb. ft.) 1-1/16-12UN-2A Thread Ordering Information DFA125C 12 Size Valve 21 Style S Override Option 22.2 (.87) Seals Type Voltage Termination THIRD-ANG PROJECTION NOTE: This valve will be available January 1, 211. Code Style (Maximum Regulated ) 21 High ( SP ) 56.8 LPM (15 GPM) Code Override Option Omit Not Available S Standard M.O. (Infinite Control) Order Bodies Separately Code Seals / Kit No. N Nitrile / Buna-N (Std.) (SK12-3LN) V Fluorocarbon / (SK12-3LV) Code Type Omit Without SP Super - 28 Watts Code Voltage Omit Without D12 12 V D24 24 V Code Termination Omit Without D DIN Plug Face A Amp Jr. Timer* S Dual Spade* L Dual Lead Wire* LS Sealed Lead Wire* H Molded Deutsch* See Super 5/8 I.D. * Only s & B12 3L A 12T 12 Size 3-Way Long Cavity Body Material Port Size Code Body Material A Aluminum Code Port Size 12T SAE

42 Catalog HY15-352/US Information Regulator Valve Series HP2P 21 General Description 2 Way, Normally Open, Regulator Valve. Partially Compensated. For additional information see Tips on pages 1-6. Features Analog Partially Compensated Regulator regulates flow proportionally to the input solenoid current The valve is designed to be used in applications where fine pressure compensation is not required and an economical solution is important One piece cartridge housing ensures internal concentricity : Waterproof, hermetically sealed, requires no O Rings; Symmetrical coil can be reversed without affecting performance. Nonmagnetic spool and housing assembly Factory-adjusted low variation option (Model L ) is available for applications where low variation of flow from valve to valve is essential at a given current or when an external pressure compensator is used. Specifications 2 to 1 19 LPM (5 GPM) 21 Bar (3 PSI) Preferable Input Port 1 Port For Best Hysteresis <1% 1 Hz PWM Performance Curves PWM Current Regulator Recommended vs. Input Current Hydraulic Oil 15 1 F (32 cst) 2 to 1 OR 1 to 2 s & Variation 35% of Rated Current & Constant P Maintained By Compensator Cartridge Material Standard Model Up To ±2% Of Rated Model L ±7% Of Rated All parts steel. All operating parts hardened steel. Operating Temp. -4 C to C (Nitrile) Range/Seals (-4 F to +2 F) C to C (Fluorocarbon) (-25 F to +25 F) Fluid Mineral-based or synthetic with Compatibility/ lubricating properties at viscosities Viscosity of 45 to 2 SSU (6 to 42 cst) Filtration ISO Code 16/13, SAE Class 4 or better Approx. Weight.8 kg (.17 lbs.) Input Current (%) Regulation (Measured at De-Energized ) 2 to 1 1 to 2 8 Hydraulic Oil 15 1 F (32 cst) 1 Cavity 2X (See Section for more details) Bar PSI

43 Catalog HY15-352/US Information Dimensions Millimeters (Inches) Regulator Valve Series HP2P (.52) Override (Infinite Control) 62.7 (2.47) 19.8 (.78) 82.4 (3.23) 39.6 (1.56) 5.59 (.22) PAT.XXXXXXX MADEINU.S.A. XXV XXW CCX XXX H 3/4 Hex. 4.1 Nm (3 lb. ft.) See Super 1/2" I.D. Information For Terminal Connectors 7/8 Hex. 27 Nm (2 lb. ft.) 33.8 (1.33) 28.5 (1.12) 3/4-16 UNF 15.9 (.63) NOTE: Requires 2X Cavity Ordering Information HP2P 21 THIRD-ANG PROJECTION 8 Size Valve Style Code Style (Maximum Regulated ) 21 High ( SP ) 19 LPM (5 GPM) Code Override Option Not Required 5 Detented M.O. (Infinite Control) Order Bodies Separately LB1 Line Body Code Porting 513 3/8 SAE 515 1/4 BSP Porting Override Option Body Material Filter Screen Code Filter Screen Not Available Code Seals / Kit No. N Nitrile / Buna-N (Std.) (SK376N-1) V Fluorocarbon / (SK376V-1) Code Body Material A Aluminum S Steel Seals Variation Type Voltage Code Variation Omit Standard Up to ±2% of Rated L Low Variation (±7% of Rated ) Code Type Omit Without SP Super - 19 Watts Termination Code Voltage Omit Without D12 12 V D24 24 V Code Termination Omit Without D DIN Plug Face A Amp Jr. Timer* L Dual Lead Wire* LS Sealed Lead Wire* H Molded Deutsch* See Super 1/2 I.D. * Only s & 42

44 Catalog HY15-352/US Information General Description 2 Way, Normally Open, Regulator Valve. Compensated. For additional information see Tips on pages 1-6. Regulator Valve Series JP2P 2, 21 Features One piece cartridge housing ensures internal concentricity : Waterproof, hermetically sealed, requires no O Rings; Symmetrical coil can be reversed without affecting performance. Nonmagnetic spool and housing assembly Factory-adjusted low variation option (Model L ) is available for applications where low variation of flow from valve to valve is essential at a given current. Port Is Not Used s & Specifications Rated LPM (2.5 GPM) Standard ( SS ) LPM (5 GPM) High ( SP ) Maximum Input 21 Bar (3 PSI) At Port 2 Minimum Bar (15 PSI) Standard Differential Bar (3 PSI) High Maximum Internal 57 cc (35 cu. in.) 21 Bar (3 PSI) <3% 1 Hz PWM Variation of Standard 35% of Rated Current Up To ±2% Of Rated Model L ±7% Of Rated Cartridge Material All parts steel. All operating parts hardened steel. Operating Temp. -4 C to C (Nitrile) Range/Seals (-4 F to +2 F) C to C (Fluorocarbon) (-25 F to +25 F) Fluid Mineral-based or synthetic with Compatibility/ lubricating properties at viscosities Viscosity of 45 to 2 SSU (6 to 42 cst) Filtration ISO Code 16/13, SAE Class 4 or better Approx. Weight.8 kg (.17 lbs.) Cavity C8-3 (See Section for more details) Performance Curves PWM Current Regulator Recommended vs. Input Current Regulation (Measured 75% of Rated Current) Bar PSI LPM GPM Hydraulic Oil 15 1 F (32 cst) Hydraulic Oil 15 1 F (32 cst) 7 1 JP2P 21 JP2P Input Current (%) 15 JP2P 21 JP2P Drop vs. PSI Bar Hydraulic Oil 15 1 F (32 cst) Measured at de-energized coil JP2P 2 JP2P

45 Catalog HY15-352/US s & Information Dimensions Millimeters (Inches) Regulator Valve Series JP2P 2, (3.78) (.52) 39.6 (1.56) 5.54 (.22) 42.5 (1.67) PAT.XXXXXXX MADEINU.S.A. XXV XXW CCX XXX H Override (Infinite Control) 3/4 Hex. 4.1 Nm (3 lb. ft.) See Super 1/2" I.D. Information For Terminal Connectors 7/8 Hex. 27 Nm (2 lb. ft.) 3/4-16 UNF 62.7 (2.47) 19.8 (.78) 33.8 (1.33) 14.2 (.56) THIRD-ANG PROJECTION Ordering Information JP2P 8 Size Valve Style Code Style (Maximum Regulated ) 2 Standard ( SS ) 9.5 LPM (2.5 GPM) 21 High ( SP ) 19 LPM (5 GPM) Code Override Option Not Required 5 Detented M.O. (Infinite Control) Code Filter Screen Not Required 1 6 Mesh Screen on Port 2 Override Option Filter Screen Seals Code Seals / Kit No. N Nitrile / Buna-N (Std.) (SK315N-1) V Fluorocarbon / (SK315V-1) Code Variation Omit Standard Up to ±2% of Rated L Low Variation (±7% of Rated ) Code Type Omit Without SS Super - 14 Watts SP Super - 19 Watts Variation Code Voltage Omit Without D12 12 V D24 24 V Type Code Termination Omit Without D DIN Plug Face A Amp Jr. Timer* L Dual Lead Wire* LS Sealed Lead Wire* H Molded Deutsch* See Super 1/2 I.D. * Only Voltage Termination Code Body Material Omit Steel A Aluminum Body Material Code Port Size Body Part No. Omit Cartridge Only 4P 1/4 NPTF (B8-3-*4P) 4T SAE-4 (B8-3-*4T) 6T SAE-6 (B8-3-*6T) 6B 3/8 BSPG (B8-3-*6B) * Add A for aluminum, omit for steel. Port Size 44

46 Catalog HY15-352/US Information Regulator Valve Series HP4P 21 General Description 2 Way, Normally Open, Regulator Valve. Partially Compensated. For additional information see Tips on pages 1-6. Features Analog Partially Compensated Regulator regulates flow proportionally to the input solenoid current The valve is designed to be used in applications where fine pressure compensation is not required and an exonomical solution is important One piece cartridge housing ensures internal concentricity : Waterproof, hermetically sealed, requires no O Rings; Symmetrical coil can be reversed without affecting performance. Nonmagnetic spool and housing assembly Factory-adjusted low variation option (Model L ) is available for applications where low variation of flow from valve to valve is essential at a given current or when an external pressure compensator is used. Specifications 21 Bar (3 PSI) <1% 1 Hz PWM Closing Point Variation of Closing Point Cartridge Material Operating Temp. Range/Seals 23 LPM (6 GPM) 65% of Rated Current Standard Model Up To ±5% Of Rated Current Model L ±2% Of Rated Current All parts steel. All operating parts hardened steel. -4 C to C (Nitrile) (-4 F to +2 F) C to C (Fluorocarbon) (-25 F to +25 F) Performance Curves PWM Current Regulator Recommended vs. Input Current Regulation Hydraulic Oil 15 1 F (32 cst) Input Current (%) 8 Hydraulic Oil 15 1 F (32 cst) Measured at de-energized coil 1 s & Fluid Compatibility/ Viscosity Mineral-based or synthetic with lubricating properties at viscosities of 45 to 2 SSU (6 to 42 cst) Filtration ISO Code 16/13, SAE Class 4 or better Approx. Weight.12 kg (.26 lbs.) Cavity C1-2 (See Section for more details) Bar PSI Differential

47 Catalog HY15-352/US s & Information Dimensions Millimeters (Inches) Regulator Valve Series HP4P (.52) 5. (1.97) 8.38 (.33) PAT.XXXXXXX MADEINU.S.A. XXV XXW CAX XXX H Override (Infinite Control) 3/4 Hex. 4.1 Nm (3 lb. ft.) See Super 5/8" I.D. Information For Terminal Connectors 66.5 (2.62) 22. (.86) 36. (1.43) 97.3 (3.83) 5.59 (.22) 1 Hex. 3 Nm (22 lb. ft.) 7/8-14 UNF 15.8 (.62) Ordering Information HP4P 21 THIRD-ANG PROJECTION 1 Size Valve Code Filter Screen Not Available Style Code Style (Maximum Regulated ) 21 High ( SP ) 3 LPM (8 GPM) Code Override Option Not Required 5 Detented M.O. (Infinite Control) Override Option Filter Screen Seals Code Seals / Kit No. N Nitrile / Buna-N (Std.) (SK353N-1) V Fluorocarbon / (SK353V-1) Code Variation Omit Standard Up to ±5% of Current L Low Variation (±2% of Current ) Code Type Omit Without SP Super - 28 Watts Opening Point Variation Code Voltage Omit Without D12 12 V D24 24 V Type Code Termination Omit Without D DIN Plug Face A Amp Jr. Timer* L Dual Lead Wire* LS Sealed Lead Wire* H Molded Deutsch* See Super 5/8 I.D. * Only Voltage Termination Code Body Material Omit Steel A Aluminum Body Material Code Port Size Body Part No. Omit Cartridge Only 4P 1/4 NPTF (B1-2-*4P) 6P 3/8 NPTF (B1-2-*6P) 8P 1/2 NPTF (B1-2-*8P) 6T SAE-6 (B1-2-*6T) 8T SAE-8 (B1-2-*8T) T8T SAE-8 (B1-2-T8T) 6B 3/8 BSPG (B1-2-*6B) * Add A for aluminum, omit for steel. Steel body only. Port Size 46

48 Catalog HY15-352/US Information General Description 2 Way, Normally Open, Regulator Valve. Compensated. For additional information see Tips on pages 1-6. Regulator Valve Series JP4P 21 Features One piece cartridge housing ensures internal concentricity : Waterproof, hermetically sealed, requires no O Rings; Symmetrical coil can be reversed without affecting performance. Nonmagnetic spool and housing assembly Factory-adjusted low variation option (Model L ) is available for applications where low variation of flow from valve to valve is essential at a given current. Port Is Not Used s & Specifications Rated 36 LPM (9.5 GPM) High ( SP ) Maximum Input 21 Bar (3 PSI) At Port 2 Minimum 14 Bar (2 PSI) Differential Maximum Internal 78 cc (46 cu. in.) 21 Bar (3 PSI) 7% 1 Hz PWM Variation of Standard 35% of Rated Up To ±2% Of Rated Current Model L ±7% Of Rated Cartridge Material All parts steel. All operating parts hardened steel. Operating Temp. -4 C to C (Nitrile) Range/Seals (-4 F to +2 F) C to C (Fluorocarbon) (-25 F to +25 F) Fluid Mineral-based or synthetic with Compatibility/ lubricating properties at viscosities Viscosity of 45 to 2 SSU (6 to 42 cst) Filtration ISO Code 16/13, SAE Class 4 or better Approx. Weight.13 kg (.28 lbs.) Cavity 3X (See Section for more details) Performance Curves PWM Current Regulator Recommended vs. Input Current Regulation Bar PSI LPM GPM Hydraulic Oil 15 1 F (32 cst) Drop vs. PSI Bar Hydraulic Oil 15 1 F (32 cst) Measured at de-energized coil Hydraulic Oil 15 1 F (32 cst) Input Current (%)

49 Catalog HY15-352/US Information Dimensions Millimeters (Inches) Regulator Valve Series JP4P (.52) Override (Infinite Control) 66.5 (2.62) 22. (.86) 3/4 Hex. 4.1 Nm (3 lb. ft.) 36. (1.43) (4.55) 5. (1.97) 5.51 (.22) PAT.XXXXXXX MADEINU.S.A. XXV XXW CAX XXX H See Super 5/8" I.D. Information For Terminal Connectors 1 Hex. 3 Nm (22 lb. ft.) (2.4) 7/8-14 UNF 17.4 (.68) NOTE: Requires 3X Cavity THIRD-ANG PROJECTION Ordering Information JP4P 21 1 Size Valve Style Code Style (Maximum Regulated ) 21 High ( SP ) 36 LPM 9.5 GPM) Code Override Option Not Required 5 Detented M.O. (Infinite Control) Order Bodies Separately LB1 Line Body Code Porting 553 1/2 SAE 554 3/8 BSP Porting Override Option Body Material Filter Screen Code Filter Screen Not Required 1 6 Mesh Screen on Port 2 Code Seals / Kit No. N Nitrile / Buna-N (Std.) (SK316N-1) V Fluorocarbon / (SK316V-1) Code Body Material A Aluminum S Steel Seals Variation Type Voltage Code Variation Omit Standard Up to ±2% of Rated L Low Variation (±7% of Rated ) Code Type Omit Without SP Super - 28 Watts Termination Code Voltage Omit Without D12 12 V D24 24 V Code Termination Omit Without D DIN Plug Face A Amp Jr. Timer* L Dual Lead Wire* LS Sealed Lead Wire* H Molded Deutsch* See Super 5/8 I.D. * Only s & 48

50 Catalog HY15-352/US Information General Description Normally Open Control Valve. For additional information see Tips on pages 1-6. N.O. Control Valve Series DF122N Features On-off type solenoids Low hysteresis PWM signal preferred override standard All external parts zinc plated Out Specifications Performance Curves In s & Rated 53 LPM (14 GPM) Valve Fully Open Maximum Inlet 21 Bar (3 PSI) Hysteresis 2 Hz PWM Frequency 1-4 Hz (2 Hz Preferred) Maximum Control 12 V 24V Current 2.45A 1.23A Cartridge Material All parts steel. All operating parts hardened steel. Operating Temp. -4 C to C (Nitrile) Range/Seals (-4 F to +2 F) C to C (Fluorocarbon) (-25 F to +25 F) Fluid Mineral-based or synthetic with Compatibility/ lubricating properties at viscosities Viscosity of 45 to 2 SSU (6 to 42 cst) Filtration ISO Code 16/13, SAE Class 4 or better Approx. Weight.32 kg (.7 lbs.) Cavity C12-2 (See Section for more details) (Q) Drop ( P) Drop No Current PSI Bar Hydraulic Oil 15 1 F (32 cst) LPM GPM (Q) vs. No Current Hydraulic Oil 15 1 F (32 cst) Bar PSI 1 2 Inlet vs. Input Signal (Current) Hydraulic Oil 15 1 F (32 cst) Form Tool Rougher None Finisher NFT12-2F Note: 4.1 Bar (6psi) is required at port 1 to fully return override. (Q) Percent of Maximum Control Current 1 49

51 Catalog HY15-352/US s & Information Dimensions Millimeters (Inches) N.O. Control Valve Series DF122N 161. (6.33) 17 (.66) 56. (2.2) See DS 1" I.D. Information For Terminal Connectors Finger Tight 6. (2.35) 48. (1.9) 1-1/4" Hex. 29 Nm (21 lb. ft.) 41.3 (1.63) 1-1/16-12 UNF-2A Thread Ø 22.2 (.87) THIRD-ANG PROJECTION Ordering Information DF122N14 12 Size Normally Open Control Valve Override Options Seals Voltage Wattage Termination Body Material Port Size Code Override Options Omit Push Type with Extenden Rod Code Seals / Kit. No. Omit Nitrile / (SK12-2) V Fluorocarbon / (SK12-2V) Code Voltage Omit Cartridge without D12 12 V D24 24 V Code Wattage Omit Cartridge without H High Watt Code Termination Omit Cartridge without D DIN P Dual Spade W Dual Wire See DS 1 I.D. Code Body Material Omit Steel A Aluminum Code Port Size Body Part No. 12P 3/4 NTPF (B12-2-*12P) 8T SAE - 8 (B12-2-*8T) 12T SAE - 12 (B12-2-*12T) * Add A for aluminum, omit for steel. 5

52 s & Catalog HY15-352/US Information General Description 3 Way, Normally Closed, Regulator Valve. Compensated. For additional information see Tips on pages 1-6. Features Analog proportional pressure compensated flow control valve regulates flow proportionally to the input solenoid current One piece cartridge housing ensures internal concentricity : Waterproof, hermetically sealed, requires no O Rings; Symmetrical coil can be reversed without affecting performance. Nonmagnetic spool and housing assembly Factory-adjusted low variation option (Model L ) is available for applications where low variation of flow from valve to valve is essential at a given current. Specifications Rated Inlet 6 LPM (16 GPM) Rated Regulated LPM (7 GPM) Standard ( SS ) 31 3 LPM (8 GPM) High ( SP ) Maximum Input 21 Bar (3 PSI) At Port 3 Minimum Bar (2 PSI) Standard Differential Bar (3 PSI) High Maximum Internal 78 cc (46 cu. in.) 21 Bar (3 PSI) 7% 1 Hz PWM Opening Point Standard 21% of Nominal Amperage High 17% of Nominal Amperage Variation of Standard Model Opening Point Up To ±5% Of Amperage Model L ±2% Of Amperage Cartridge Material All parts steel. All operating parts hardened steel. Operating Temp. -4 C to C (Nitrile) Range/Seals (-4 F to +2 F) C to C (Fluorocarbon) (-25 F to +25 F) Fluid Mineral-based or synthetic with Compatibility/ lubricating properties at viscosities Viscosity of 45 to 2 SSU (6 to 42 cst) Filtration ISO Code 16/13, SAE Class 4 or better Approx. Weight.14 kg (.31 lbs.) Cavity 4C (See Section for more details) Regulator Valve Series JP4C 31 * (4) *Always connect Port to Port (4) through.39" orifice. Reg. (4) Inlet Bypass Not Used Performance Curves PWM Current Regulator Recommended Compensation of Regulated (Port 4) Drop vs. at Fully Energized PSI Bar Hydraulic Oil 15 1 F (32 cst) Regulated vs. Input Current Stabilized Bar 21 PSI LPM GPM By-Pass Load Higher Than Regulated Hydraulic Oil 15 1 F (32 cst) 7 1 Hydraulic Oil 15 1 F (32 cst) Input Current (%) * Regulated Load Higher Than By-Pass

53 XXV XXW CAX XXX H PAT.XXXXXXX MADEINU.S.A. Catalog HY15-352/US Information Dimensions Millimeters (Inches) Regulator Valve Series JP4C (.52) 8.38 (.33) Override (Infinite Control) (Screw Adjust) 66.5 (2.62) 22. (.86) (5.25) 5. (1.97) 5.59 (.22) Reg. (4) 3/4 Hex. 4.1 Nm (3 lb. ft.) See Super 5/8" I.D. Information For Terminal Connectors 1 Hex. 3 Nm (22 lb. ft.) 7/8-14 UNF 36. (1.43) In Byp (.62) Ext. Pilot NOTE: Requires 4C Cavity THIRD-ANG PROJECTION Ordering Information JP4C 1 Size Valve Style Code Style (Maximum Regulated ) 31 Standard ( SS ) 26 LPM (7 GPM) 31 High ( SP ) 3 LPM (8 GPM) Code Override Option Not Required 5 Screw Adjust Order Bodies Separately LB1 Line Body Code Porting 562 1/2 SAE 563 3/8 BSP 31 Porting Override Option Body Material Filter Screen Code Filter Screen Not Available Code Seals / Kit No. N Nitrile / Buna-N (Std.) (SK382N-1) V Fluorocarbon / (SK382V-1) Code Body Material A Aluminum S Steel Seals Variation Type Voltage Code Variation Omit Standard Up to ±5% of Opening Amps L Low Variation (±2% of Opening Amps) Code Type Omit Without SS Super - 18 Watts SP Super - 28 Watts Termination Code Voltage Omit Without D12 12 V D24 24 V Code Termination Omit Without D DIN Plug Face A Amp Jr. Timer* L Dual Lead Wire* LS Sealed Lead Wire* H Molded Deutsch* See Super 5/8 I.D. * Only s & 52

54 s & Catalog HY15-352/US Information General Description 3 Way, Normally Closed, Regulator Valve. Compensated. For additional information see Tips on pages 1-6. Features Analog proportional pressure compensated flow control valve regulates flow proportionally to the input solenoid current One piece cartridge housing ensures internal concentricity : Waterproof, hermetically sealed, requires no O Rings; Symmetrical coil can be reversed without affecting performance. Specifications Rated Inlet Rated Regulated Maximum Input At Port 3 Minimum Differential Maximum Internal Leakage >15% 1 Hz PWM Cartridge Material Operating Temp. Range/Seals Fluid Compatibility/ Viscosity 75 LPM (2 GPM) 56.8 LPM (15 GPM) Requires ( SP ) 21 Bar (3 PSI) 13.8 Bar (2 PSI) 568 cc (35 cu. 21 Bar (3 PSI) All parts steel. All operating parts hardened steel. -4 C to C (Nitrile) (-4 F to +2 F) C to C (Fluorocarbon) (-25 F to +25 F) Mineral-based or synthetic with lubricating properties at viscosities of 45 to 2 SSU (6 to 42 cst) Filtration ISO Code 16/13, SAE Class 4 or better Approx. Weight Cavity.45 kg (1. lbs.) C12-4L (See Section for more details) Regulator Valve Series DFA125C31 * (4) *Always connect Port to Port (4) through.39" orifice. Reg. (4) Inlet Bypass Not Used Performance Curves PWM Current Regulator Recommended Compensation of Regulated (Port 4) Regulated vs. Input Current Stabilized By-Pass Load Higher Than Regulated Bar 21 PSI PSI Bar Hydraulic Oil 15 1 F (32 cst) Hydraulic Oil 15 1 F (32 cst) 25 5 Input Current (%) Drop vs. (Through cartridge only) Hydraulic Oil 15 1 F (32 cst) LPM GPM (Q) * Regulated Load Higher Than By-Pass

55 XXV XXW CAX XXX H PAT.XXXXXXX MADEINU.S.A. Catalog HY15-352/US Information Regulator Valve Series DFA125C31 Dimensions Millimeters (Inches) 15.7 (.62) 8.7 (.34) 2.5 (.1) Override (Infinite Control) 66.5 (2.62) 22. (.86) Finger Tight to 4.1 Nm (3 lb. ft.) Max. 36. (1.43) 99.5 (3.92) 5. (1.97) See Super 5/8" I.D. Information For Terminal Connectors 2.3 (7.88) 4.8 (.19) 19.1 (.75) Reg. (4) 1-1/4" Hex. 74 Nm (55 lb. ft.) 1-1/16-12UN-2A Thread 1.6 (3.96) In Byp. Ext. Pilot THIRD-ANG PROJECTION Ordering Information DFA125C 31 S 12 Size Valve Code Override Option Omit Not Available S Standard M.O. (Infinite Control) Style Code Style (Maximum Regulated ) 31 High ( SP ) 56.8 LPM (15 GPM) Code Seals / Kit No. N Nitrile / Buna-N (Std.) (SK12-4LN) V Fluorocarbon / (SK12-4LV) Override Option Code Type Omit Without SP Super - 28 Watts Code Voltage Omit Without D12 12 V D24 24 V Seals Type Voltage Code Termination Omit Without D DIN Plug Face A Amp Jr. Timer* S Dual Spade* L Dual Lead Wire* LS Sealed Lead Wire* H Molded Deutsch* See Super 5/8 I.D. * Only Termination Order Bodies Separately B12 12 Size Code Body Material A Aluminum 4L A 12T 4-Way Long Cavity Body Material Code Port Size 12T SAE - 12 Port Size s & 54

56 s & Catalog HY15-352/US Information General Description 4 Way, 3 Position, Control Valve. Closed Center Spool. For additional information see Tips on pages 1-6. Features One piece cartridge housing ensures internal concentricity : Waterproof, hermetically sealed, requires no O Rings; Symmetrical coil can be reversed without affecting performance. Specifications Operating Ports 2, 3 and 4 35 Bar (5 PSI) Port 1 21 Bar (3 PSI) <6% 1 Hz PWM Cracking 25% to 3% of Input Signal Variation of 75% of Nominal Current and Constant P Maintained by Compensator Port to Port 1 cu. 3 PSI Leakage Step Response On 5 ms Time at 75% of Off 4 ms Amps Cartridge Material All parts steel. All operating parts hardened steel. Operating Temp. -4 C to C (Nitrile) Range/Seals (-4 F to +2 F) C to C (Fluorocarbon) (-25 F to +25 F) Fluid Mineral-based or synthetic with Compatibility/ lubricating properties at viscosities Viscosity of 45 to 2 SSU (6 to 42 cst) Filtration ISO Code 16/13, SAE Class 4 or better Approx. Weight.15 kg (.34 lbs.) Cavity C8-4 Typical Performance SPOOL TYPE AND FLOW 51L Low 51 Standard 52 High RATED FLOW AT 75% OF NOMINAL CURRENT LPM - (GPM) a SONOID PU P to A, B to T b SONOID PULL P to B, A to T SUPER COIL TYPE PU PULL Compensator P Bar (PSI) (1.4) (1.4) SP SP 1 (15) (.9) (.9) SS SS 5 (75) (3.5) 17 - (4.5) SP SP 15 (22) (3.) (4.) SS SS 15 (22) 21 - (5.5) 17 - (4.5) SP SP 2 (29) (4.5) 13 - (3.5) SP SP 15 (22) Control Valve Series GP2 51, 51L, 52 (4) Performance Curves PWM Current Regulator Recommended 51L With 5 Bar, 75 PSI Compensator 51 With 15 Bar, 22 PSI Compensator and SS V.6 12V 1.2 1% 51L vs. Load Bar PSI PU 'a' % % % (4) Current Amps Hydraulic Oil 15 1 F (32 cst) % % Hydraulic Oil 15 1 F (32 cst) P to A, B to T P to B, A to T 28 4 PULL 'b' % 52 With 2 Bar, 29 PSI Compensator and SP V.8 12V 1.6 1% % Hydraulic Oil 15 1 F (32 cst) PU 'a'.4.8 5% % Current Amps % PULL 'b' % % 51L P to B, A to T % P to A, B to T Not Compensated Compensated With Hydrostat P = 25 psi %

57 Catalog HY15-352/US s & Information Dimensions Millimeters (Inches) Control Valve Series GP2 51, 51L, (3.71) 39.6 (1.56) b PAT.XXXXXXX MADEINU.S.A. XXV XXW CCX XXX H 3/4 Hex. 4.1 Nm (3 lb. ft.) 27. (1.8) 6. (.25) Stroke M.O. Option (Unlatch and Pull or Push) Latching Sleeve 62.7 (2.47) 19.8 (.78) 33.8 (1.33) 53. (2.1) 39.6 (1.56) (4) a 7/8 Hex. 3 Nm (22 lb. ft.) See Super 1/2" I.D. Information For Terminal Connectors Sample Application Circuit (Closed Center) 3 2(A) 2 4(B) 1 Ordering Information GP2 8 Size Valve Style 12.7 (.5) Override Option Seals Type THIRD-ANG PROJECTION Voltage Termination Body Material Port Size Compensator (R4H3) 3 3(P) 1 2 1(T) Code Style - Closed Center ( and Performance) 51 Standard 51L Low 52 High Code Override Option Omit Not Required 1 Override 2 Detented M.O. Code Seals / Kit No. N Nitrile / Buna-N (Std.) (SK378N-1) V Fluorocarbon / (SK378V-1) Code Type Omit Without SS Super - 14 Watts SP Super - 19 Watts Code Voltage Omit Without D12 12 V D24 24 V Code Termination Omit Without D DIN Plug Face A Amp Jr. Timer* L Dual Lead Wire* LS Sealed Lead Wire* H Molded Deutsch* See Super 1/2 I.D. * Only Code Body Material Omit Steel A Aluminum Code Port Size Body Part No. Omit Cartridge Only 4T SAE-4 (B8-4-*4T) 6T SAE-6 (B8-4-*6T) 6B 3/8 BSPG (B8-4-*6B) * Add A for aluminum, omit for steel. 56

58 s & Catalog HY15-352/US Information General Description 4 Way, 3 Position, Control Valve. Floating Center Spool. For additional information see Tips on pages 1-6. Features One piece cartridge housing ensures internal concentricity : Waterproof, hermetically sealed, requires no O Rings; Symmetrical coil can be reversed without affecting performance. Specifications Operating Ports 2, 3 and 4 35 Bar (5 PSI) Port 1 21 Bar (3 PSI) <6% 1 Hz PWM Cracking 25% to 3% of Input Signal Variation of 75% of Nominal Current and Constant P Maintained by Compensator Port to Port 1 cu. 3 PSI Leakage Step Response On 5 ms Time at 75% of Off 4 ms Amps Cartridge Material All parts steel. All operating parts hardened steel. Operating Temp. -4 C to C (Nitrile) Range/Seals (-4 F to +2 F) C to C (Fluorocarbon) (-25 F to +25 F) Fluid Mineral-based or synthetic with Compatibility/ lubricating properties at viscosities Viscosity of 45 to 2 SSU (6 to 42 cst) Filtration ISO Code 16/13, SAE Class 4 or better Approx. Weight.15 kg (.34 lbs.) Cavity C8-4 Typical Performance SPOOL TYPE AND FLOW 53L Low 53 Standard 54 High RATED FLOW AT 75% OF NOMINAL CURRENT LPM - (GPM) a SONOID PU P to A, B to T b SONOID PULL P to B, A to T SUPER COIL TYPE PU PULL Compensator P Bar (PSI) (1.4) 5 - (1.4) SP SP 1 (15) 4 - (1.) 4 - (1.) SS SS 5 (75) 14 - (3.8) 15 - (4.) SP SP 1 (15) 9 - (2.5) 1 - (2.7) SS SS 5 (75) 17 - (4.5) 19 - (5.) SP SP 2 (29) 15 - (4.) 15 - (4.) SS SS 15 (22) Control Valve Series GP2 53, 53L, 54 (4) Performance Curves PWM Current Regulator Recommended 53 and 53L With 5 Bar, 75 PSI Compensator and SS L 24V.6 12V 1.2 1% PU 'a' % PU 'a'.3.6 5% % (4) Current Amps Hydraulic Oil 15 1 F (32 cst) %.3.6 5% PULL 'b' % 54 With 2 Bar, 29 PSI Compensator and SP 24V.8 12V 1.6 1% vs. Load Bar PSI % Hydraulic Oil 15 1 F (32 cst).4.8 5% % 14 Current Amps % % Hydraulic Oil 15 1 F (32 cst) P to A, B to T P to B, A to T 28 4 PULL 'b' % 53L P to B, A to T % % P to A, B to T Not Compensated Compensated With Hydrostat P = 25 psi

59 Catalog HY15-352/US s & Information Dimensions Millimeters (Inches) Control Valve Series GP2 53, 53L, (3.71) 39.6 (1.56) b PAT.XXXXXXX MADEINU.S.A. XXV XXW CCX XXX H 3/4 Hex. 4.1 Nm (3 lb. ft.) 27. (1.8) 6. (.25) Stroke M.O. Option (Unlatch and Pull or Push) Latching Sleeve 62.7 (2.47) 19.8 (.78) 33.8 (1.33) 53. (2.1) 39.6 (1.56) (4) a 7/8 Hex. 3 Nm (22 lb. ft.) See Super 1/2" I.D. Information For Terminal Connectors Sample Application Circuit (Floating Center) 3 2(A) 2 4(B) 1 Ordering Information GP2 8 Size Valve Style 12.7 (.5) Override Option Seals Type THIRD-ANG PROJECTION Voltage Termination Body Material Port Size Compensator (R4H3) 3 3(P) 1 2 1(T) Code Style - Floating Center ( and Performance) 53 Standard 53L Low 54 High Code Override Option Omit Not Required 1 Override 2 Detented M.O. Code Seals / Kit No. N Nitrile / Buna-N (Std.) (SK378N-1) V Fluorocarbon / (SK378V-1) Code Type Omit Without SS Super - 14 Watts SP Super - 19 Watts Code Voltage Omit Without D12 12 V D24 24 V Code Termination Omit Without D DIN Plug Face A Amp Jr. Timer* L Dual Lead Wire* LS Sealed Lead Wire* H Molded Deutsch* See Super 1/2 I.D. * Only Code Body Material Omit Steel A Aluminum Code Port Size Body Part No. Omit Cartridge Only 4T SAE-4 (B8-4-*4T) 6T SAE-6 (B8-4-*6T) 6B 3/8 BSPG (B8-4-*6B) * Add A for aluminum, omit for steel. 58

60 Catalog HY15-352/US Information General Description 4 Way, 3 Position, Control Valve. Closed Center or Floating Center Spool. For additional information see Tips on pages 1-6. Control Valve Series DSP15C1, C4 s & Features One piece cartridge housing ensures internal concentricity : Waterproof, hermetically sealed, requires no O Rings; Symmetrical coil can be reversed without affecting performance. All external parts zinc plated Specifications Operating <6% 1 Hz PWM Cracking Variation of Port to Port Leakage 21 Bar (3 PSI) 25% to 3% of Input Signal 75% of Nominal Current and Constant P Maintained by Compensator 1 cu. 3 PSI Step Response On 5 ms Time at 75% of Off 4 ms Amps Cartridge Material Operating Temp. Range/Seals Fluid Compatibility/ Viscostiy All parts steel. All operating parts hardened steel. -45 C to C ( D -Ring) (-5 F to +2 F) C to C (Fluorocarbon) (-25 F to +25 F) Mineral-based or synthetic with lubricating properties at viscosities of 45 to 2 SSU (6 to 42 cst) Filtration ISO Code 16/13, SAE Class 4 or better Approx. Weight Cavity C kg (.57 lbs.) CLOSED NTER (4) FLOATING NTER (4) Sample Application Circuit Closed Center Compensator (R4H3-15.) Floating Center Compensator (R4H3-15.) (A) 3(P) 1 2 2(A) 3(P) (B) 1(T) 4(B) 1(T) (4) PSI Valve is recommended in Tank Line 1 PSI Valve is recommended in Tank Line 59

Catalog HY /US SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. LPM/GPM BAR/PSI

Catalog HY /US SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. LPM/GPM BAR/PSI Catalog HY15-351/US Contents SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. LPM/GPM BAR/PSI PRESSURE RELIEVING AP1B2YP... 2G... Increase /Increase Current...5.3/1.4... 35/5... 7-8 AP2A2... C8-2... Increase

More information

P.C. Priority Flow Control Valve Series J02D3. General Description

P.C. Priority Flow Control Valve Series J02D3. General Description CV Catalog HY15-352/US General Description Needle Type, Compensated Regulator Valve. For additional information see Tips on pages 1-4. P.C. Priority Control Valve Series J2D3 Features Good adjustment from

More information

Pressure Control Valves

Pressure Control Valves Catalog HY15-351/US Contents RELIEF VALVES SEQUEN VALVES Control SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. /GPM BAR/ DIRECT ACTING RDH42... C4-2... Direct Acting Relief, Poppet Type... 3.8/1...

More information

DMH085** Series will be available January 1, Catalog HY /US SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO.

DMH085** Series will be available January 1, Catalog HY /US SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. Catalog HY-/US Contents SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. /GPM BAR/PSI DL8... C8-... Position, Way, N.C. Poppet,... Pull to Open.../8... /... DL... C-... Position, Way, N.C. Poppet,... Pull

More information

CVH103P. Check Valve Series CVH103P. Technical Information. General Description

CVH103P. Check Valve Series CVH103P. Technical Information. General Description Catalog HY-351/US Information Cartridge Style Valve. For additional information see Tips on pages 1-4. Valve Series H13P Spherical poppet for low leakage D -Ring eliminates back-up rings Dual sense paths

More information

Pressure Control Valves

Pressure Control Valves Control Valves DR8- Reducing/Relieving, Direct Acting, Spool Type 4 gpm (5 l/min) 6 psi (4 bar) Description A screw-in cartridge, direct acting, spool type, pressure reducing/relieving valve with internal

More information

Proportional Valves. Proportional solenoid valves for pressure and flow control B-1.A. An Eaton Brand

Proportional Valves. Proportional solenoid valves for pressure and flow control B-1.A. An Eaton Brand Proportional Valves Proportional solenoid valves for pressure and flow control An Eaton rand -.A Proportional Valves Valve Locator/Section Contents Note: Proportional valve solenoid coils and electronic

More information

Pressure Control Valves

Pressure Control Valves CV Catalog HY15-3501/US Contents RELIEF VALVES SEQUEN VALVES Control SERIES CAVITY DESCRIPTION FLOW PRESSURE LPM/GPM BAR/PSI DIRECT ACTING RDH042... C04-2... Direct Acting Relief, Poppet Type... 3.8/1...

More information

Hydraulic Screw-in Cartridge Valves (SiCV) Proportional valves Proportional solenoid valves for pressure and flow control

Hydraulic Screw-in Cartridge Valves (SiCV) Proportional valves Proportional solenoid valves for pressure and flow control Hydraulic Screw-in Cartridge Valves (SiCV) Proportional valves Proportional solenoid valves for pressure and flow control Proportional valves PROPORTIONAL VALVES... - PFRH... -8 EPV...- EPV6...- EPV6A...-7

More information

Directional Control Valves

Directional Control Valves Overview HYDAC offers several functions of the Directional Control Cartridges. HYDAC Manually operated position, - way normally closed, spring return, directional valve features poppet design. It offers

More information

Solenoid Valves. Poppet and Spool type solenoid actuated valves for applications up to 350 bar (5000 psi) and 227 L/min (60 USgpm) A-1.

Solenoid Valves. Poppet and Spool type solenoid actuated valves for applications up to 350 bar (5000 psi) and 227 L/min (60 USgpm) A-1. Solenoid Valves Poppet and Spool type solenoid actuated valves for applications up to 5 bar (5 psi) and 7 L/min (6 USgpm) n Eaton Brand ETON Screw-In Cartridge Valves E-VLSC-MC-E November 9 -. Solenoid

More information

Proportional Valves MODEL DESCRIPTION FLOW CAVITY 4/3 PROPORTIONAL DIRECTIONAL VALVE 8 GPM C1040 PDFC-4M PDFC-4L

Proportional Valves MODEL DESCRIPTION FLOW CAVITY 4/3 PROPORTIONAL DIRECTIONAL VALVE 8 GPM C1040 PDFC-4M PDFC-4L Proportional Valves MODEL DESCRIPTION FLOW CAVITY 4 b a PDFC-4M 4/3 PROPORTIONAL DIRECTIONAL VALVE 8 GPM C040 4 3 b a PDFC-4L 3 3 EPRR-0 PROPORTIONAL PRESS. REDUCING/RELIEVING GPM C030 EPRT-08 PROPORTIONAL

More information

Proportional Valves. Proportional solenoid valves for pressure and flow control

Proportional Valves. Proportional solenoid valves for pressure and flow control Proportional Valves Proportional solenoid valves for pressure and flow control EATON Vickers Screw-In Cartridge Valves V-VLOV-MC-E4 September, 7 - Electro- Proportional Valves Section Contents Typical

More information

Solenoid valves. Poppet and Spool type solenoid actuated valves for applications up to 350 bar (5000 psi) and 227 L/min (60 USgpm)

Solenoid valves. Poppet and Spool type solenoid actuated valves for applications up to 350 bar (5000 psi) and 227 L/min (60 USgpm) Hydraulic Screw-in Cartridge Valves (SiCV) Solenoid valves Poppet and Spool type solenoid actuated valves for applications up to 5 bar (5 psi) and 7 L/min (6 USgpm) Solenoid valves SOLENOID VLVES...- SV5-8-C/CM

More information

Logic elements. Differential pressure sensing elements for applications up to 350 bar (5000 psi) and 400 L/min (100 USgpm)

Logic elements. Differential pressure sensing elements for applications up to 350 bar (5000 psi) and 400 L/min (100 USgpm) Hydraulic Screw-in Cartridge Valves (SiCV) Logic elements Differential pressure sensing elements for applications up to 50 bar (5000 psi) and 400 L/min (00 USgpm) Logic elements LOGC ELEMENTS... -4 APPLCATON

More information

Catalog HY /US Flow Control Valves SERIES CAVITY DESCRIPTION FLOW PRESSURE LPM/GPM BAR/PSI

Catalog HY /US Flow Control Valves SERIES CAVITY DESCRIPTION FLOW PRESSURE LPM/GPM BAR/PSI Contents SERIES CAVITY DESCRIPTION FLOW PRESSURE LPM/GPM BAR/PSI NEED VALVES J02A2... C08-2... Needle Valve, Cartridge Type...45/12... 420/6000... NVH081... C08-2... Needle Valve, Cartridge Type...38/10...

More information

Pressure Control Valves. General Description. Specifications. Ordering Information

Pressure Control Valves. General Description. Specifications. Ordering Information Catalog HY14-3000/US Technical Information Control Valves Series RCP General escription Series RCP in-line pressure control valves are chiefly used as remote control valves. They limit system pressure

More information

SERIES Waterman* DESCRIPTION FLOW PRESSURE PAGE NO.

SERIES Waterman* DESCRIPTION FLOW PRESSURE PAGE NO. Contents SERIES Waterman* DESCRIPTION FLOW PRESSURE PAGE NO. NVH081...12CNVH1...Needle Valve...10 GPM... 5500 PSI... FC5-FC6 NVH101...15CNVH1...Needle Valve...16 GPM... 5500 PSI... FC7-FC8 NV162...21CNV2...Needle

More information

Pressure Compensator Valves Series R5P (SAE Flange Mounted) General Description. Features

Pressure Compensator Valves Series R5P (SAE Flange Mounted) General Description. Features Technical Information General Description Series R5P direct operated, 3-way pressure compensators can be combined with any type of fixed or adjustable flow resistor (throttle) to provide a load compensated

More information

Large Electronically Adjustable Proportional Pressure Compensated Flow Control Engineering & Manufacturing Solutions

Large Electronically Adjustable Proportional Pressure Compensated Flow Control Engineering & Manufacturing Solutions Engineering & Manufacturing Solutions LEFC Specifications: See flow chart for capacity. Max. 3000 psi cartridge input pressure. Nominally Rated for 3000 psi (207 bar). Tank Port - #4 SAE (10 psi (0.69

More information

DRV2-080 Adjustable, Direct-Acting Relief Valve

DRV2-080 Adjustable, Direct-Acting Relief Valve SOLENOID DRV2-080 Adjustable, Direct-Acting Relief Valve SERIES 8 CHECK MOTION FLOW USASI / ISO ➁ ➀ DESCRIPTION An adjustable, direct-acting poppet cartridge valve designed to limit pressure in hydraulic

More information

Colorflow and Ball Valves. Industrial Flow Control, Check, Gauge Control. Catalog HY /US

Colorflow and Ball Valves. Industrial Flow Control, Check, Gauge Control. Catalog HY /US Colorflow and Industrial Flow Control, Check, Gauge Control Catalog HY14-3300/US Colorflow and Fully guided poppets are used on Colorflow valves rather than the less durable ball-check type construction.

More information

Vickers. Proportional Valves. EPV10 Series. Proportional Flow Controls. Released 6/95

Vickers. Proportional Valves. EPV10 Series. Proportional Flow Controls. Released 6/95 Vickers Proportional Valves EPV1 Series Proportional Flow Controls Released 6/95 715 Table of Contents Features and Benefits..............................................................................

More information

GPM PSI LPM BAR MODEL CAVITY PAGE IF-S3A special IF-S3D special IG-S4A special 198

GPM PSI LPM BAR MODEL CAVITY PAGE IF-S3A special IF-S3D special IG-S4A special 198 Transmission & Brake Spool Valves Screw-in style GPM PSI LPM BAR MODEL CAVITY PAGE 2 1000 8 70 TC-S3A 5/8-18 186 6 1000 23 70 TF-S3A 7/8-14 188 6 1000 23 70 TF-S3D 7/8-14 190 5 1000 20 70 TG-S4A 7/8-14

More information

DOUBLE, P.O. CHECK VALVES (PRE-ENGINEERED BLOCKS)

DOUBLE, P.O. CHECK VALVES (PRE-ENGINEERED BLOCKS) DOUBLE, P.O. CHECK VALVES (PRE-ENGINEERED BLOCKS) SERIES DOUBLE PILOT OPERATED CHECK VALVE... HS3 Page HD1 Page HD2 SERIES DOUBLE PILOT OPERATED CHECK VALVE GPM PSI LPM BAR CAVITY MODEL PAGE 5 3500 19

More information

Check valves Direct and pilot operated check valve functions for applications up to 350 bar (5000 psi) and 227 L/min (60 USgpm)

Check valves Direct and pilot operated check valve functions for applications up to 350 bar (5000 psi) and 227 L/min (60 USgpm) Hydraulic Screw-in Cartridge Valves (SiCV) Check valves Direct and pilot operated check valve functions for applications up to 5 bar (5 psi) and 7 L/min (6 USgpm) Check valves CHECK VALVES... -4 FPR -

More information

LOAD SENSE SECTIONS. Series 20. Directional Control Valves NEED NEW PIC VALVES STANDARD FEATURES SPECIFICATIONS

LOAD SENSE SECTIONS. Series 20. Directional Control Valves NEED NEW PIC VALVES STANDARD FEATURES SPECIFICATIONS Directional Control Valves LOAD SENSE SECTIONS NEED NEW PIC Series 20 STANDARD FEATURES Control and reduced Dead Band (20I) and Tie Rod Kits SPECIFICATIONS Pressure Rating Foot Mounting Maximum Operating

More information

Series PVP Variable Volume Piston Pumps

Series PVP Variable Volume Piston Pumps Series PVP Variable Volume Piston Pumps Catalog HY28-2661-CD/US zp2 hpm12-1.p65, lw, jk 1 Notes Series PVP hpm12-1.p65, lw, jk 2 Introduction Series PVP Series Sizes 6-14 Phased Out For Reference Only

More information

3-Way heavy duty flow control, with pressure compensated, solenoid and load sensing controlled priority flow

3-Way heavy duty flow control, with pressure compensated, solenoid and load sensing controlled priority flow 3-Way heavy duty flow control, with pressure compensated, solenoid and load sensing controlled priority flow A-VRFC3C-VEI-VS-LS 0M.43.21.80 - Y - Z RE 18309-63 Edition: 03.2018 Replaces: 03.2016 Technical

More information

PRESSURE CONTROLS TECNORD

PRESSURE CONTROLS TECNORD Pressure Reducing / Relieving Valves GPM PSI LPM BAR MODEL PAGE 1 4 38 276 DF-PRP 174 2 3 76 27 SK-PRP 176 1 4 38 276 DF-PWP 178 Typical Schematic Typical application for the PRP and PWP is multi-system

More information

unrestricted; preferably with coil at bottom (auto. air bleed) 12 or 24 Volt DC from an electronic controller Deutsch plug - IP67

unrestricted; preferably with coil at bottom (auto. air bleed) 12 or 24 Volt DC from an electronic controller Deutsch plug - IP67 3 Technical data General characteristics Design Flow direction Seals De-energized position Mounting attitude Description, value, unit line mounting P A controlled P R surplus flow discharge (models shown

More information

BW0511FP. ByWire Elements BW0511FP Flow Sharing Element Interface IBW0511

BW0511FP. ByWire Elements BW0511FP Flow Sharing Element Interface IBW0511 ywire Elements Flow Sharing Element Interface IW05 efore use, carefully read the GENERL INSTRUCTIONS FOR USE OF DIRECTIONL CONTROL VLVES Technical data Nominal flow Nominal pressure 35 l/min - P=8 bar

More information

Flow Control Valve. 1 Description. 2 Symbols. Series SRCA General. 1.2 Application examples way flow control way flow control

Flow Control Valve. 1 Description. 2 Symbols. Series SRCA General. 1.2 Application examples way flow control way flow control Flow Control Valve Series SRC.. plug-in coil for easy coil change flow rates are unaffected by changes in temperature or load compact design reduced p ZnNi coating (>70h DIN EN ISO 97 NSS) Description.

More information

Delta Power Company 4484 Boeing Drive - Rockford, IL 61109

Delta Power Company 4484 Boeing Drive - Rockford, IL 61109 4484 Boeing Drive - Rockford, IL 6119 SECTION/Description Pages Logic Elements 4 Page 43 Page 44 4484 Boeing Drive - Rockford, IL 6119 Logic Elements GPM PSI LPM BAR MODEL PAGE 4 3 14 241 SL-PLA 46 4 3

More information

Flow Control Valve. 1 Description. 2 Symbols. Series SRCA General. 1.2 Application examples way flow control way flow control

Flow Control Valve. 1 Description. 2 Symbols. Series SRCA General. 1.2 Application examples way flow control way flow control Flow Control Valve Series SRC.. plug-in coil for easy coil change flow rates are unaffected by changes in temperature or load. compact reduced p ZnNi coating (>70h DIN EN ISO 97 NSS) Description. General

More information

Proportional Directional Control Cartridge Valves: PSV10-34 & PSV12-34

Proportional Directional Control Cartridge Valves: PSV10-34 & PSV12-34 Control Cartridge Valves: PSV10-34 & PSV12-34 SCHEMATIC PRESSURE* FLOW CAVITY COIL Page 2 PSV10-34-02 250 BAR 3600 PSI 22 LPM 6 GPM SDC10-4 M16-26W R16-20W Page 4 PSV12-34-02 260 BAR 3770 PSI 50 LPM 13

More information

Pressure Reducing Valves

Pressure Reducing Valves 5 Pressure Reducing Valves MODEL DESCRIPTION FLOW CAVITY PAGE NO. 3 PRPS-0 PRESSURE REDUCING VALVE GPM C030 5-0.0 3 PRRS-08 PRRS-0 PRRS- 6 GPM GPM 4 GPM C0830 C030 C30 5-0.0 5-0.0 5-03.0 Reference: 50-P-050000-EN-00/09.05

More information

Proportional Flow-Control Cartridges, Size 5

Proportional Flow-Control Cartridges, Size 5 Proportional Flow-Control Cartridges, Size Q max = l/min, p max = bar, Q N = l/min at p bar Leak free, load compensated, two stage Description Series MVRPLSA two-stage proportional flow-control cartridges

More information

ELECTRIC CARTRIDGES ELECTRO-PROPORTIONAL VALVES

ELECTRIC CARTRIDGES ELECTRO-PROPORTIONAL VALVES ELECTRIC CARTRIDGES ELECTRO-PROPORTIONAL VALVES 6. 9 ELECTRO-PROPORTIONAL VALVES ELECTRIC CARTRIDGES ELECTRO-PROPORTIONAL VALVES In the follow of this chapter, NEM presents the electro-proportional flow

More information

Flow Control Valves Check Valves Gauge Control Valves. Colorflow Valves

Flow Control Valves Check Valves Gauge Control Valves. Colorflow Valves Check Valves Gauge Control Valves Colorflow Valves Colorflow and Ball Valves Industrial Flow Control, Check, Gauge Control Catalog HY14-3300/US Colorflow and Ball Valves Fully guided poppets are used on

More information

EFC. Electronically Adjustable Proportional Pressure Compensated Flow Control

EFC. Electronically Adjustable Proportional Pressure Compensated Flow Control Engineering & Manufacturing Solutions Specifications: See flow chart for capacity. 3000 psi (207 bar) rating. Weighs 8-1/2 lbs. (3.9 kg). Standard Port size #12SAE (1-1/16 12). 10-Micron Filtration Recommended.

More information

Catalog HY /US SERIES DESCRIPTION PAGE NO. SUPER COILS CC... 1/2 Solenoid Tubes... CE3-CE4 CA... 5/8 Solenoid Tubes...

Catalog HY /US SERIES DESCRIPTION PAGE NO. SUPER COILS CC... 1/2 Solenoid Tubes... CE3-CE4 CA... 5/8 Solenoid Tubes... Contents Coils and SERIES DESCRIPTION PAGE NO. SUPER COILS CC... 1/2 Tubes... 3-4 CA... 5/8 Tubes... 5-6 STANDARD COILS Unicoil... 1/2 Tubes... 7-8 Unicoil... 5/8 Tubes... 9-10 DS... 1/2 Tubes... 11-12

More information

Catalog HY /NA. Catalog HY /NA. Parker Hannifin Corporation Hydraulic Pump Division Marysville, Ohio USA

Catalog HY /NA. Catalog HY /NA. Parker Hannifin Corporation Hydraulic Pump Division Marysville, Ohio USA Catalog HY28-6/NA PV, PVT Series Piston Pumps Variable Volume Catalog HY28-6/NA 1 Catalog HY28-6/NA Notes Series PV 2 Catalog HY28-6/NA Introduction Series PV Quick Reference Data Chart Pump Delivery Approx.

More information

PRPM2-A. = 5.5 Nm (4.1 lb.-ft.) (qual. 8.8 Nm (6.5 lb.-ft.) for socket cap screws. = 50 Nm (36.9 lb.-ft.) for cartridges

PRPM2-A. = 5.5 Nm (4.1 lb.-ft.) (qual. 8.8 Nm (6.5 lb.-ft.) for socket cap screws. = 50 Nm (36.9 lb.-ft.) for cartridges Technical Information General Description proportional pressure reducing valves keep a constant pressure p red on the secondary, or regulated, side, independent of pressure fluctuations on the primary

More information

Pressure Control Valves Series R. General Description. Specifications. Flow Data

Pressure Control Valves Series R. General Description. Specifications. Flow Data Catalog Y14-2502/US Technical Information Series R General Description Series R direct relief valves limit system pressure by opening to tank when system pressure reaches the valve setting. Specifications

More information

NG6. Proportional adjustment. Manifold mounting acc. to ISO External drain. Main stage spool type valve. Pilot stage seated type valve.

NG6. Proportional adjustment. Manifold mounting acc. to ISO External drain. Main stage spool type valve. Pilot stage seated type valve. Catalog HY14-255/US Technical Information Series VY*K General Description Series VY*K pilot operated sequence valves feature proportional adjustment and an external drain. The external drain allows application

More information

CLS100 Proportional Load Sensing Mobile Valve

CLS100 Proportional Load Sensing Mobile Valve Mobile Valves Proportional - Load Sensing Model CLS100 350 bar 100 L/min Up to 10 sections Eaton Pro-FX TM Compliant CLS100 Proportional Load Sensing Mobile Valve Overhaul manual / Trouble shooting guide

More information

Cartridge Valves Technical Information Directional Valves DCV 03

Cartridge Valves Technical Information Directional Valves DCV 03 OVERVIEW DCV 03 directional control valves consist of: housing (1), control spool (5), with two centering springs (4), and cylindrical operating solenoids (2, 3). The three-position directional valves

More information

Publ. 3-EN 2950-A. DENISON HYDRAULICS Pressure Relief Valve R6V

Publ. 3-EN 2950-A. DENISON HYDRAULICS Pressure Relief Valve R6V Publ. 3-EN 2950-A DENISON HYDRAULICS Pressure Relief Valve R6V FEATURES, SYMBOL FEATURES High Performance: R6V valves are designed for a maximum pressure of 350 bar and a flow capacity up to 650 l/min.

More information

PILOT OPERATED PRESSURE CONTROLS - FLANGED TYPE VR5 Series

PILOT OPERATED PRESSURE CONTROLS - FLANGED TYPE VR5 Series PILOT OPERTED PRESSURE CONTROLS FLNGED TPE VR5 Series Veljan Flanged type, Valves Series VR5V ( Relief ), VR5U (Unloader) and VR5S (Sequence ) are pilot controls. These range of valves are suitable for

More information

Directional Control Valve Series D3W (Parker), 4D02 (Denison)

Directional Control Valve Series D3W (Parker), 4D02 (Denison) Characteristics Series D3W (Parker), 4D0 (Denison) The direct operated directional control valve size NG10 is available with both Parker (series D3W) and Denison (series 4D0) model codes. Both series are

More information

Available manual, pneumatic, and hydraulic spool control kits.

Available manual, pneumatic, and hydraulic spool control kits. Fitted with a main pressure relief valve and a load check valve on every working section. Available with parallel circuit. Optional carry-over Variety of port valves (auxiliary valves) Available manual,

More information

Sectional Directional Control Valve RSQ 240

Sectional Directional Control Valve RSQ 240 Sectional Directional Control Valve RSQ 0 Key valve features RSQ 0 is a sectional open center valve, designed for max. operating pressures up to 50 bar and max. pump flows up to 00 l/min. It is available

More information

3-Way heavy duty flow control, with pressure compensated and solenoid controlled priority flow

3-Way heavy duty flow control, with pressure compensated and solenoid controlled priority flow 3-Way heavy duty flow control, with pressure compensated and solenoid controlled priority flow A-VRFC3C-VEI-VS 0M.43.20.80 - Y - Z RE 18309-3 Edition: 03.2018 Replaces: 03.2016 Technical data Description

More information

Chapter 5: Flow Valves

Chapter 5: Flow Valves Catalogue HY11-300/UK Contents Chapter : Flow Valves Series Description Size Mounting Page Parker Standard DIN / ISO 1/4 3/8 1/2 3/4 1 06 10 16 Throttle valves, manual adjustment MVI -2 NS -4 FS With free

More information

Super Charged Piston Pumps Variable Displacement For Open Circuits. PAVC Medium Pressure

Super Charged Piston Pumps Variable Displacement For Open Circuits. PAVC Medium Pressure aerospace climate control electromechanical filtration fluid & gas handling hydraulics pneumatics process control sealing & shielding PAVC Medium Pressure Super Charged Piston Pumps Variable Displacement

More information

Post-Compensated Proportional Valve CV2000LS

Post-Compensated Proportional Valve CV2000LS www.nimco-controls.com Post-Compensated Proportional Valve CV2000LS Smart Solutions... for the Future Contents Page 5 Page 6 Page 7 Page 8 Page 9 Page 10 Page 11 Page 12 Page 13 Page 14 Page 15 Page 16

More information

NG06. General Size NG6 NG10 Design

NG06. General Size NG6 NG10 Design Catalog HY14-255/US Series VY*K General Series VY*K pilot operated sequence valves feature proportional adjustment and an external drain. The external drain allows application as both a sequence valve

More information

Industrial Hydraulic Valves. Directional Control, Pressure Control, Sandwich, Subplates & Manifolds, Accessories. Catalog HY /US

Industrial Hydraulic Valves. Directional Control, Pressure Control, Sandwich, Subplates & Manifolds, Accessories. Catalog HY /US Industrial Hydraulic Valves irectional Control, Pressure Control, Sandwich, Subplates & Manifolds, Accessories Catalog HY14-25/US Industrial Hydraulic Valves WARNING USER RESPONSIBILITY FAILURE OR IMPROPER

More information

4 WAY DIRECTIONAL CONTROL VALVE AO

4 WAY DIRECTIONAL CONTROL VALVE AO B Certificate 4 WAY DIRECTIONAL CONTROL VALVE AO ISO 91:2 WITH DESIGN #2.2.1 AO12O4LS B A P T AO12T4JRD FEATURES: SMALL AND COMPACT to fit your design requirements. POSITIVE METERING in either direction

More information

Mobile Directional Valve. Product Catalog MDG for Mobile Equipment Flows to 60 I/min (15.8 USgpm)

Mobile Directional Valve. Product Catalog MDG for Mobile Equipment Flows to 60 I/min (15.8 USgpm) Mobile Directional Valve Product Catalog MDG for Mobile Equipment Flows to 60 I/min (15.8 USgpm) Table of Contents General Information...3 Model code Valve Section...4 Valve Assembly...5 Spool Data...6

More information

Directional Control Valve Series 4D01 (DENISON)

Directional Control Valve Series 4D01 (DENISON) Characteristics The Denison series 4D01 is a solenoid operated directional control valve size NG06 in -chamber design. It is direct operated by wet pin solenoids. The 4D01 is available with a Soft Shift

More information

Super Charged Piston Pumps Variable Displacement For Open Circuits. PAVC Medium Pressure

Super Charged Piston Pumps Variable Displacement For Open Circuits. PAVC Medium Pressure aerospace climate control electromechanical filtration fluid & gas handling hydraulics pneumatics process control sealing & shielding PAVC Medium Pressure Super Charged Piston Pumps Variable Displacement

More information

VALVES RANGE FOR OPEN LOOPS T E C H N I C A L C A T A L O G

VALVES RANGE FOR OPEN LOOPS T E C H N I C A L C A T A L O G VALVES RANGE FOR OPEN LOOPS T E C H N I C A L C A T A L O G Valves range for open loop 2 18/07/2017 Valves range for open loop CONTENT CHECK VALVES 5 Direct operated valves 7 Pilot operated valves 11 Counterbalance

More information

SV9A-10-E - Solenoid Valve 4-way, 3-position spool type solenoid valve Up to 36 L/min (9.5 USgpm) 210 bar (3000 psi)

SV9A-10-E - Solenoid Valve 4-way, 3-position spool type solenoid valve Up to 36 L/min (9.5 USgpm) 210 bar (3000 psi) SV9--E - Solenoid Valve -way, -position spool type solenoid valve Up to 6 L/min (9.5 USgpm) bar ( psi) () () (P) (T) In the de-energized position all ports are closed. When solenoid '' is energized flow

More information

Directional Control Valve Series D3W Soft Shift

Directional Control Valve Series D3W Soft Shift Characteristics The D3W is a 3-chamber, electrically controlled 4/3 or 4/ way directional control valve. It is activated directly by solenoids with screwed in wet pin armature. The soft shifting of this

More information

LogSplitterPlans.Com

LogSplitterPlans.Com Hydraulic Pump Basics LogSplitterPlans.Com Hydraulic Pump Purpose : Provide the Flow needed to transmit power from a prime mover to a hydraulic actuator. Hydraulic Pump Basics Types of Hydraulic Pumps

More information

3-Way heavy duty flow control, with pressure compensated and solenoid controlled priority flow

3-Way heavy duty flow control, with pressure compensated and solenoid controlled priority flow 3-Way heavy duty flow control, with pressure compensated and solenoid controlled priority flow A-VRFC3C-VEI-VS 0M.43.20.80 - Y - Z RE 18309-3 Edition: 03.2016 Replaces: 06.2010 Technical data Description

More information

PVX-11 VANE PUMPS. See pages 12 thru 14 for PVX-11 dimensions. VARIABLE DISPLACEMENT, PRESSURE COMPENSATED PERFORMANCE SPECIFICATIONS

PVX-11 VANE PUMPS. See pages 12 thru 14 for PVX-11 dimensions. VARIABLE DISPLACEMENT, PRESSURE COMPENSATED PERFORMANCE SPECIFICATIONS PVX-11 VANE PUMPS VARIABLE DISPLACEMENT, COMPENSATED NOTE: See pages thru 14 for PVX-11 dimensions. PERFORMANCE SPECIFICATIONS Displacement (Nominal) 1.5 in 3 /rev. (25 cm 3 /rev.) Displacement (Actual)

More information

Chapter 6: Check Valves

Chapter 6: Check Valves Contents Chapter : Check Valves Series Description Size Mounting Page Parker Standard DIN / ISO 1/8 1/4 3/8 1/2 3/4 1 0 10 1 25 32 Subplate Screw-in Slip-in Shuttle valves SSR -2 Check valves, direct operated

More information

High Speed Hydraulic Motors. Catalog HY /NA zm16 zm17

High Speed Hydraulic Motors. Catalog HY /NA zm16 zm17 High Speed Hydraulic Motors Catalog HY13-20-0-001/NA zm16 zm17 223 Introduction High Speed Features High Starting Torque typically 90% of running torque. Smooth Output Torque throughout the entire speed

More information

DC Series. 4-Way Directional Control Valve With Or Without Flow Control PDC16T4PBS PDCF16TM454LF

DC Series. 4-Way Directional Control Valve With Or Without Flow Control PDC16T4PBS PDCF16TM454LF Engineering & Manufacturing Solutions Specifications: Rated for 0-45 gpm (0-170 lpm) Rated for 3000 psi (207 bar) Std. port sizes (Consult factory for others) - 3/4 NPT all ports - #16 SAE (1-5/16-12)

More information

Full Range Pressure Compensating Variable Flow Control

Full Range Pressure Compensating Variable Flow Control Engineering & Manufacturing Solutions Specifications: See flow chart for capacity. Rated for 3000 psi (207 bar). Weighs 7- ¾ lbs. (3.52 kg). 30-Micron Filtration Recommended. Torque to turn side lever

More information

CLS180 Proportional Load Sensing Mobile Valve

CLS180 Proportional Load Sensing Mobile Valve Mobile valves Proportional Load Sensing, Model CLS180 350 bar 180 L/min Up to 10 sections Eaton Pro-FX TM Ready CLS180 Proportional Load Sensing Mobile Valve Overhaul manual / Trouble shooting guide Contents

More information

Chapter 6: Check Valves

Chapter 6: Check Valves Contents Chapter : Check Valves Series Description Size Mounting Page Parker Standard DIN / ISO 1/8 1/4 3/8 1/2 3/4 1 0 10 1 25 32 Subplate Screw-in Slip-in SSR RK / RB CS SPZBE SPV / SPZ C4V CPS C4V D4S

More information

Cartridge Valves. Proportional Valves Screw-in Cartridge Valves. Vickers. Maximum Pressure 280 bar (4000 psi) - Maximum Flow 160 l/min (42 USgpm)

Cartridge Valves. Proportional Valves Screw-in Cartridge Valves. Vickers. Maximum Pressure 280 bar (4000 psi) - Maximum Flow 160 l/min (42 USgpm) Vickers Cartridge Valves Proportional Valves Screw-in Cartridge Valves Maximum Pressure 8 bar (4 psi) - Maximum Flow 6 l/min (4 USgpm) Revised 7/ 76 Contents MODEL DESCRIPTION TYPICL PPLICTION PRESSURE

More information

VSD10M DIRECTIONAL CONTROL VALVES SOLENOID ACTUATED, PILOT OPERATED

VSD10M DIRECTIONAL CONTROL VALVES SOLENOID ACTUATED, PILOT OPERATED NFPA SIZE D10 TYPICAL PERFORMANCE SPECIFICATIONS Performance is measured on a four-way circuit (full circuit). Performance may be reduced from that shown if a three-way circuit (half circuit) is used,

More information

VER03MP CONTINENTAL HYDRAULICS PROPORTIONAL PRESSURE RELIEF VALVES PILOT OPERATED VER03MP - PROPORTIONAL PRESSURE RELIEF VAVLES PILOT OPERATED

VER03MP CONTINENTAL HYDRAULICS PROPORTIONAL PRESSURE RELIEF VALVES PILOT OPERATED VER03MP - PROPORTIONAL PRESSURE RELIEF VAVLES PILOT OPERATED CONTINENTAL HYDRAULICS VER03MP PROPORTIONAL PRESSURE RELIEF VALVES PILOT OPERATED VER03MP - PROPORTIONAL PRESSURE RELIEF VAVLES PILOT OPERATED 5505 WEST 123RD STREET SAVAGE, MN 55378-1299 / PH: 952.895.6400

More information

High Speed Hydraulic Motors

High Speed Hydraulic Motors High Speed Hydraulic Motors Catalog HY13-20-0-001/NA C C225 Introduction High Speed Features High Starting Torque typically 90% of running torque. Smooth Output Torque throughout the entire speed range

More information

Chapter 10: Valves for Pipe Mounting

Chapter 10: Valves for Pipe Mounting Contents Chapter : Valves for Pipe Mounting Series Description Size Body Page DIN / ISO 1/8 1/4 3/8 1/2 3/4 1 1¼ 1½ 2 L-port T-port Pressure valves, manual operation R4V R4R Pressure relief function Pressure

More information

Pilot Operated Pressure Relief Valve Series R5V (Denison)

Pilot Operated Pressure Relief Valve Series R5V (Denison) Characteristics Pilot operated pressure relief valves series R5V have a similar design to the subplate mounted R4V series. The SAE flanges allow to mount the valves directly on the outlet flanges of pumps

More information

Directional Control Valve Series D1VW

Directional Control Valve Series D1VW Characteristics The NG6 directional control valve series D1VW provides high functional limits up to 8 l/min in combination with a very low, energy-saving pressure drop. A wide variety of spool options

More information

Sandwich Valves Series CP

Sandwich Valves Series CP Technical Information General Description. pilot operated check valves are designed for maximum flow rates. The valves are typically used in combination with spool type directional control valves to ensure

More information

Série D3 Válvula Direcional CETOP 5 e NG 10. Catálogo HY /US

Série D3 Válvula Direcional CETOP 5 e NG 10. Catálogo HY /US Série D3 Válvula Direcional CETOP 5 e NG 10 Catálogo HY14-2502/US Catalog HY14-2502/US Introduction pplication Series D3 hydraulic directional control valves are high performance, direct operated 4-way

More information

Proportional pressure reducing valve, pilot operated

Proportional pressure reducing valve, pilot operated Proportional pressure reducing valve, pilot operated RE 29177/07.05 1/10 Type DRE6X Nominal size 6 Unit series 1X Maximum working pressure P 315 bar, T 250 bar Maximum flow rate 40 l/min List of Contents

More information

MONOBLOCK DIRECTIONAL CONTROL VALVES

MONOBLOCK DIRECTIONAL CONTROL VALVES MONOBLOCK DIRECTIONAL CONTROL VALVES CONTENTS: RM0...... RM5...... RM40P...... RM80...... RMD90...... MRP70... Page 1/19&/19 /19...5/19 6/19...10/19 11/19...15/19 16/19&17/19 18/19&19/19 MONOBLOCK DIRECTIONAL

More information

Mobile Valves Proportional - Load Sensing

Mobile Valves Proportional - Load Sensing Mobile Valves Proportional - Load Sensing Model CML60 325 bar 60 L/min Up to 8 sections Eaton F(x) Compliant Table of Contents General Information... 3 Model Code Valve Section... 4 Valve Assembly... 5

More information

Directional Seat Valve Series D4S (Denison)

Directional Seat Valve Series D4S (Denison) Characteristics Seat valves series D4S are designed for directional control functions. A large variety of poppets, springs and covers - including shuttle valves, stroke limiters, solenoid valves (VV01)

More information

Directional Control Valves Series D111VW. General Description. Features. Performance Curves

Directional Control Valves Series D111VW. General Description. Features. Performance Curves Technical Information General valves are piloted by a D1VW valve. The valves can be ordered with position control. The minimum pilot pressure must be ensured for all operating conditions of the directional

More information

Vickers Pressure Relief Solenoid Operated, Two-Stage Directional Control Valve DG5S4-02 Flows to 115 l/min (30 USgpm) Pressure to 210 bar (3000 psi)

Vickers Pressure Relief Solenoid Operated, Two-Stage Directional Control Valve DG5S4-02 Flows to 115 l/min (30 USgpm) Pressure to 210 bar (3000 psi) Vickers Pressure Relief Solenoid Operated, Two-Stage Directional Control Valve DG5S4-02 Flows to 115 l/min (30 USgpm) Pressure to 210 bar (3000 psi) Revised 2/93 GB C 2037 Table of Contents Model Code...................................................................................................

More information

VED*M PROPORTIONAL PILOT OPERATED DIRECTIONAL CONTROL VALVES

VED*M PROPORTIONAL PILOT OPERATED DIRECTIONAL CONTROL VALVES CONTINENTAL HYDRAULICS VED*M PROPORTIONAL PILOT OPERATED DIRECTIONAL CONTROL VALVES 5505 WEST 123RD STREET SAVAGE, MN 55378-1299 / PH: 952.895.6400 / WWW.CONTINENTALHYDRAULICS.COM TOUGH VED*M PROPORTIONAL

More information

ANTI-SHOCK DIRECTIONAL CONTROL VALVES

ANTI-SHOCK DIRECTIONAL CONTROL VALVES ACTUATED, DIRECT OPERATED TYPICAL PERFORMANCE SPECIFICATIONS Performance is measured on a four-way circuit (full circuit). Performance may e reduced from that shown if a three-way circuit (half circuit)

More information

Vickers. Proportional Valves. EPV16 Series Valvistor Proportional Flow Controls

Vickers. Proportional Valves. EPV16 Series Valvistor Proportional Flow Controls Vickers Proportional Valves EPV6 Series Valvistor Proportional Flow Controls Vickers, Incorporated, 998 All rights reserved Features and Benefits The EPV (Electro Proportional Valve) series of poppet valves

More information

Sectional Directional Control Valve RS 220

Sectional Directional Control Valve RS 220 Sectional Directional Control Valve RS 0 RS 0 is a sectional open center valve designed for max. operating pressures up to 00 bar and max. pump flows up to 0 l/min. Technical data Pressure and flow values*

More information

Flow Control Valve. 1 Descriptions. 2 Symbols. Series SRCB Generals. 1.2 Application examples way flow control way flow control

Flow Control Valve. 1 Descriptions. 2 Symbols. Series SRCB Generals. 1.2 Application examples way flow control way flow control Flow Control Valve Series SRC.. plug-in solenoid for easy coil change flow rates are unaffected by temperature change or when the higher load pressure alternates between the outlet ports energy - optimised

More information

* Optional PRESSURE COMPENSATOR - FLANGED TYPE B A X 2.2. Typical application VR5P with flow control valve

* Optional PRESSURE COMPENSATOR - FLANGED TYPE B A X 2.2. Typical application VR5P with flow control valve * Veljan 3 ports pressure compensator Valve are designed for improved operation safety and reduced mountg cost. These valves are used to mata a constant pressure drop External PD, External PP Internal

More information

Nominal sizes 08 to 10, special cavities

Nominal sizes 08 to 10, special cavities Nominal sizes 08 to 10, special cavities RE 18301-91 Edition: 05.2016 Replaces: 07.2012 Contents Relief, direct acting guided poppet type Common cavity, Size 10 2 Relief, direct acting guided poppet type

More information

Chapter 13: Application of Proportional Flow Control

Chapter 13: Application of Proportional Flow Control Chapter 13: Application of Proportional Flow Control Objectives The objectives for this chapter are as follows: Review the benefits of compensation. Learn about the cost to add compensation to a hydraulic

More information

SD2E-A3. Functional Description. 3/2 Way Solenoid Operated Directional Control Valves Spool Type HA /2013. Replaces HA /2012

SD2E-A3. Functional Description. 3/2 Way Solenoid Operated Directional Control Valves Spool Type HA /2013. Replaces HA /2012 3/2 Way Solenoid Operated Directional Control Valves Spool Type SD2E-A3 3/4-6 UNF p max 350 bar (5076 PSI) Q max 30 L/min (7.9 GPM) HA 404 /203 Replaces HA 404 07/202 Hardened and precision working parts

More information

Directional Control Valve

Directional Control Valve Characteristics The NG6 directional control valve series D1VW provides high functional limits up to 8 l/min in combination with a very low, energy-saving pressure drop. wide variety of spool options allows