Proportional Valves. Proportional solenoid valves for pressure and flow control B-1.A. An Eaton Brand

Size: px
Start display at page:

Download "Proportional Valves. Proportional solenoid valves for pressure and flow control B-1.A. An Eaton Brand"

Transcription

1 Proportional Valves Proportional solenoid valves for pressure and flow control An Eaton rand -.A

2 Proportional Valves Valve Locator/Section Contents Note: Proportional valve solenoid coils and electronic valve drivers are covered in section C of this Catalog. Proportional Valve Cartridges Section Overview...-5 Functional Symbol (In) Flow Typical Model Cavity Rating Pressure Page Proportional bi-directional poppet L/min (USgpm) bar (psi) PFRH A879 8 (5) (3) - (Out) Flow Typical Model Cavity Rating Pressure Page Proportional bi-directional poppet L/min (USgpm) bar (psi) EPV C-- -3 (-8) 35 (5) - EPV6A EPV6 Flow Typical Model Cavity Rating Pressure Page Proportional flow control, NC, poppet L/min (USgpm) bar (psi) EPV6A C-6-35 (undercut) -6 8 (4) - EPV6 C-6-35 (undercut) -6 8 (4) Flow Typical Model Cavity Rating Pressure Page Proportional flow control, NC, poppet L/min (USgpm) bar (psi) ESV-8-C C-8-3 (9) (3) -3 ESV--C C-- 7 (9) (3) -4 ESV--C C-- 4 (7) (3) -5 Flow Typical Model Cavity Rating Pressure Page Proportional flow control, NO, poppet L/min (USgpm) bar (psi) ESV-8-O C-8-3 (9) (3) -6 ESV--O C-- 7 (9) (3) -7 ESV--O C-- 4 (7) (3) -8 Flow Typical Model Cavity Rating Pressure Page Proportional flow control, NC, spool L/min (USgpm) bar (psi) EFV--C C () (3) -9 EFV--C C () (3) - Flow Typical Model Cavity Rating Pressure Page Proportional flow control, NO, spool L/min (USgpm) bar (psi) EFV--O C--3 3 () (3) - EFV--O C--3 4 (8) (3) - -.A An Eaton rand

3 Proportional Valves Valve Locator/Section Contents Functional Symbol Flow Typical Model Cavity Rating Pressure Page Proportional flow L/min (USgpm) bar (psi) PFR4A A67 8 (5) (3) -3 Flow Typical Model Cavity Rating Pressure Page Proportional flow, NC, spool L/min (USgpm) bar (psi) EFV--C C--3 <4 (3) (3) -5 3 Flow Typical Model Cavity Rating Pressure Page Proportional flow, NO, spool L/min (USgpm) bar (psi) EFV--O C--3 <4 (<3) (3) -6 3 Flow Typical Model Cavity Rating Pressure Page Proportional relief L/min (USgpm) bar (psi) PDRA A879.5 (.3) 35 (5) -7 An Eaton rand -3.A

4 Proportional Valves Valve Locator/Section Contents Functional Symbol Flow Typical Model Cavity Rating Pressure Page Proportional inverse relief, poppet L/min (USgpm) bar (psi) IRV- C-- (.5) (3) -8 Flow Typical Model Cavity Rating Pressure Page Proportional relief, spool L/min (USgpm) bar (psi) ERV- C-- <6 (5) (3) -9 ERV-6 C-6- <3 (<39) (3) -3 Flow Typical Model Cavity Rating Pressure Page Proportional reducing/relief, spool L/min (USgpm) bar (psi) PPDA A879 (5) (3) -3 EPRV-8 C () 35 (5) -3 3 Flow Typical Model Cavity Rating Pressure Page Proportional reducing/relief, spool L/min (USgpm) bar (psi) EPRV-6 C () 35 (5) A An Eaton rand

5 Proportional Valves Section Overview This section gives basic specifications for the complete line of Vicker s screw-in proportional control valves. Its purpose is to provide a quick, convenient reference tool when choosing proportional valves or when designing a system using these components. The EPV has several outstanding performance features which give it a unique position in the screwin cartridge valve market. Valve gain linearity, flow force pressure compensation characteristics above bar (3 psi) and low internal leakage. The EPV6 is a proportionally controlled two-way poppet type valve. The main poppet amplifies a small flow through the pilot circuit and is comparable to a transistor. As the transistor uses small currents to control larger currents, the hydraulic valve transistor or VALVISTOR uses the pilot flow to control the main stage flow with servolike response flow to control. The ESV is a proportional two-way, pressure compensated, poppet type flow control valve. The valve is available in 8,, and sizes, both normally open or normally closed in the de-energized position. The EFV is a proportionally controlled two-way, spool type flow control valve. Technically the valve is not pressure compensated, but it is partial flow force pressure compensated. The EFV is a three port, pressure compensated, proportional flow control valve. The valve can be used as a priority flow regulator, with regulated flow being supplied to port 3 and excess flow being by-passed to port. If port is blocked the valve functions as a restrictive, way, pressure compensated flow regulator. The ERV- is an electric, proportionally controlled, internally pilot operated, spool type screw-in relief valve. It is capable of handling flows from 3,8-6, L/min (-5 USgpm) at pressures from 35- bar (5-3 psi). Also available is an ERV-6 which is capable of handling flows from 7,6-3 L/min. (-35 USgpm) at pressures from 35- bar (-5 psi). The ERV- is a low flow electric proportionally controlled relief valve similar to the ERV-. This valve is rated for flows from,-,8 L/min ( USgpm) and pressures up to 35 bar (5 psi). The ERV3- is a low flow electric proportionally controlled relief valve similar to the ERV-. This valve is rated for flows up to,8 L/min (. USgpm) and pressures up to 7 bar (3 psi). The EPRV-8 is an electric, proportionally controlled, direct acting spool type, screw-in pressure reducing/ relieving valve. It is capable of handling flows from -7,6 L/min (- USgpm) at set pressures from - bar (-3 psi). The EPRV- is an electric, proportionally controlled, internally pilot operated, spool type, screw-in pressure reducing/relieving valve. It is capable of handling flows from -7,6 L/min (- USgpm) at set pressures from 4-35 bar (-5 psi). Also available is an ERV-6 which is capable of handling flows from -38 L/min (- USgpm) at set pressures from 4-35 bar (-5 psi). The EPRV3- is an electric, proportionally controlled, internally pilot operated, spool type, screw-in pressure reducing/relieving valve. It is capable of handling flows from -3 L/min (-8 USgpm) at set pressures from 35-7 bar (5-3 psi). Vickers proportional pressure and flow control valves are designed to be easily controlled by the simplest of DC electrical devices such as a volt battery and a potentiometer. Varying the voltage at the coil is one of the simplest means of control available. Any of the Vickers DC coils will work on most of these valves simply by varying the voltage between and 75% of the rated coil voltage. It should be noted that as the operating temperature of a coil increases, the solenoid force decreases. Therefore if the voltage is held constant as the coil heats up then valve pressure (or flow) will change. The IRV is a proportionally controlled poppet type, relief valve, with an inverse function. This valve is capable of handling flows up to L/min (.5 USgpm) and pressures up to bar (3 psi). Electrical current controls with PWM are recommended for all Eaton proportional valves. Closed-loop electrical control with feedback from the parameter to be monitored will provide the most accurate control. Valve Features and enefits Products in this catalog have been fatigue tested to one million cycles at 3% or million cycles at 5% of rated pressure All operating parts are hardened steel, ground and honed for long life and low leakage Designed for maximum flexibility and minimal space requirements All exposed cartridge surfaces are zinc dichromate plated to resist corrosion Reliable, economical and compact Rated flows up to 6 L/min (4 USgpm) Optional nose-in, side-out or side-in, nose out flow direction (EPV6 series) Coil Features and enefits The valves in this catalog are offered with a choice of two or three standard voltages and several types of electrical connections. For other coil ratings and connections, consult your Eaton applications engineer. Variety of voltages and terminations Coils are interchangeable for serviceability on the EPV and EPV6. Coils are interchangeable for serviceability on the ERV-, EPV-6, EPRV- and EPRV-6 Compact, one-piece weather-proof encapsulated design. Eliminates need for extra seals An arc suppression diode molded into the coil is available as a standard option on ERV, EPRV and EFV valves Fluid Cleanliness Proper fluid condition is essential for long and satisfactory life of hydraulic components and systems. Hydraulic fluid must have the correct balance of cleanliness, materials, and additives for protection against wear of components, elevated viscosity, and inclusion of air. WARNING Application of these products beyond published performance specifications may cause valve malfunction which may result in personal injury and/or damage to the machine. WARNING For pressures over bar (3 psi) use steel housing. An Eaton rand -5.A

6 PFRH - Proportional Valve Proportional bi-directional poppet, flow control valve Up to 8L/min (5 USgmp) bar (3 psi) (In) Operation Features (Out) Sectional View In the de-energised position the valve is blocked in both directions. As the current to the coil is increased the valve opens proportionally. There is also an element of compensation as the pressure difference across the valve increases. See performance graphs. High flow capacity with reduced space requirements. Standard valve bodies and common cavities. One-piece encapsulated coil with minimal amperage draw. Oil immersed armature solenoid.. Various coil terminals and voltages. Coil interchangeability with valves of same series. Manual override, seal variations and other options available. Sealed coil arrangement to protect stem from corrosion. Reversible coil without affecting performance. Description This is a proportionally operated way poppet valve. Ideal for use in lowering circuits to give good control to the operator. The valve will compensate as the pressure difference increases to prevent speed increase due to increasing load. Performance Data Ratings and Specifications Performance data is typical with fluid at 3 cst (5 SSU) Max inlet pressure bar (3 psi) Max regulated flow at rated 5 bar L/min (5.3 5 L/min (3.9 L/min (.9 Frequency to 4 Hz - recommended Dead band 38-6% of rated current Response time 8ms Internal leakage Up to.67 ml/min (dpi) bar differential at 3 centistrokes Temperature range (oil) -3 to C (- to 48 F) Cavity A67 (see Section M) Electrical data See coil data sheet Torque cartridge into cavity 3 Nm ( lbs ft) Mounting position Unrestricted Fluids Most general purpose hydraulics fluids Seal material Standard nitrile with PTFE back up rings Filtration S554/4 Class 6/3 (5 micron or better) Nominal viscosity range 5 to 5 cst Standard housing materials Aluminium Coil model code C6-*-*/9 Voltage available, 4 VDC Coil weight.3 kg (.6 lbs) Weight. kg (.44 lbs) Seal kit SK38 (Nitrile) SK38V (Viton ) Viton is a registered trademark of E.I. DuPont Pressure Drop Viscosity = 3 cst (5 SSU) % Flow - L/min 3 3 Pressure - psi 4 7 Pressure - bar Flow - US gpm Performance Curves 5 bar bar 4 3 Flow - L/min Flow - US gpm Pressure differential - bar % of rated amps 6% of rated amps % of rated amps 4 3 Flow - L/min Flow - US gpm % related amps 3 Pressure differential - psi -.A An Eaton rand

7 PFRH - Proportional Valve Proportional bi-directional poppet, flow control valve Up to 8L/min (5 USgmp) bar (3 psi) Model Code PFRH N 6 H 4 3W Function PFRH - Normally closed Seal Material N - Nitrile V - Viton 3 Manual Override 6 - Screw 4 Coil Termination H - DIN4365 F - Flying Lead DM - Deutsch moulded Other terminations available on request. 5 Voltage - VDC 4-4 VDC 6 Port Size Code Port Size Housing Number lank Cartridge only W /4" SP A59 3W 3/8" SP A745 6T 3/8" SAE A9355 Dimensions mm (inch) Cartridge Only Installation Drawing. (.87) 48. (.89) 35.5 (.4) 5. (.97) M/O plate fitted by customer holes Ø6.8 (.7) thro.8 (.53) 98. (3.86) 5. (.97) 6. (.63) 9. (.75) 6. (.4). (.87) 6. (.4) 5.9 (.63) 5.8 (.) 3.8 (.5) 4 A/F 6.5 (.4) 8.9 (.74) 3/4-6-UNF-A Ø5.8 (.6) An Eaton rand -.A

8 EPV - Proportional Valve Proportional uni-directional poppet, flow control valve Up to 3L/min (8 USgmp) 35 bar (5 psi) Operation Features In the de-energized condition, blocked from port to with no reverse flow permitted. When energized, flow is allowed from port to port in direct proportion to the current applied to the solenoid coil. Hardened, ground and honed working parts to limit leakage. IP69K Tough coil compatibility. Continuously rated. Compact design with low pressure drop. Sectional View Description This is a uni-directional proportionally controlled, normally closed poppet valve. It is ideal for lowering circuits controlling the speed of movement with low leakage when closed. Performance Data Ratings and Specifications Performance data is typical with fluid at,8 cst (5 SSU) and 49 C ( F) Typical application pressure (at port ) 35 bar (5 psi) Cartridge fatigue pressure (infinite life) 35 bar (5 psi) Rated flow - 3 L/min ( - 8 USgpm) Operating ambient temperature -3 to 9 C (- to 94 F) Cavity C-- Fluids Anti-wear hydraulic oils with una-n seals (standard) Phosphate esters (non-alkyl) with Viton seals are available by request Viton is a registered trademark of E.I. DuPont Weight cartridge only,78 kg (.7 lbs) Filtration 7 - bar ( - 3 psi) Cleanliness code 7/5/ + bar (3+ psi) Cleanliness code 5/3/ Standard housing materials Aluminum or Steel Typical hysteresis Less than 4% of rated current at bar pressure drop Pulse Width Modulated (PWM) Internal leakage cm 3 4 bar ( psi) and oil viscosity of 3 cst Oil viscosity range - 8 cst Nominal supply voltage or 4 VDC Threshold current Adj from 3-6 ma ( VDC) Adj from 5-3 ma (4 VDC) Coil max flow.7 amps 4 VDC.4 amps VDC Recommended PWM frequency - Hz application dependent, 5 Hz typ Coil C (86 F) V-6.5Ω 4V-5.Ω Power rated current V-.8 watts and C coil temperature 4V-.8 watts Cartridge seal kit (una-n) -.A An Eaton rand

9 EPV - Proportional Valve Proportional uni-directional poppet, flow control valve Up to 3L/min (8 USgmp) 35 bar (5 psi) Model Code EPV * ** ** *** (*) * ** Function EPV - Electro-proportional flow control valve, poppet type Size - Size 3 Valve Housing Material Omit for cartridge only A - Aluminum S - Steel Maximum operating pressure for aluminum housing is bar (3 psi) 5 Seal Material N - una-n V - Viton NF - una-n and 6 mesh filter screen VF - Viton and 6 mesh filter screen Dimensions mm (inch) 4 Port Size Code Port Size Housing Number Aluminium Steel Cartridge only 3G 3/8" SPP H SAE H SAE T SAE T SAE See section J for housing details. 8 Coil/Connector Types Connector lank No Coil VDC 4VDC W Leadwire (DC only) Q Spade terminals (DC only) U DIN Y Metri-Pack 5 male* F Weather-Pack male *Preferred Packard connector. Ø 6,7 (.5) 6 Voltage Rating D - VDC 4D - 4VDC 7 Manual Override Option lank - No manual override M - Pin type S - Screw type Manual override is available in two different configurations, either push pin type is used when system pressure does not exceed bar (3 psi). The screw type can be used at any system pressure. 9 Design Number Cartridge Only Manual override Valve is shown with U coil. See Section C for coil information. Torque cartridge in housing A Nm (35-4 ft. lbs) S Nm (5-55 ft. lbs) Ø 43,5 (.7) Ø 5,8 (.) WARNING WARNING 8,5 (3.7) 3,4 (5.7) 4,9 (.65) The cavity should be machined to the 4,9 (.56) maximum diameter and 36, (.47) maximum depth. See Section M. When using the Screw Type override, care must be taken to return the override back to its neutral position before activating the valve. Failure to take this precaution may result in personal injury or damage to the machine. Opening clearance, (.8) 34, (.34).875"-4 Thd. Ø 5,8 (.6) An Eaton rand -.A

10 EPV - Proportional Flow Control Valve Performance curves Step Response Data Flow response in % of max flow On stroke 35 msec Typical current step to provide 5% flow Off stroke Time - sec Flow vs Current With bar differential between inlet and outlet A - bar (3 psi) pressure drop from Port to Port - bar (5 psi) pressure drop from Port to Port Flow - USgpm A 3 Flow - L/min % Current - ma -.A An Eaton rand

11 EPV - Proportional Flow Control Valve Performance curves Flow vs Pressure Drop Per % of Input Current L/min USgpm Flow Pressure drop - psi 3 A - % of input current - 85% of input current C - 7% of input current D- 57% of input current E - 43% of input current Pressure drop - bar Typical Flow Response For an amplitude of +_ 4% maximum stroke (center to offset) about the 5% position. P = bar (45 psi) -3 A Phase lag - degrees -6.4 Hz Hz Hz Hz A - d - Phase Lag Frequecy Hz An Eaton rand -3.A

12 EPV6 - Proportional Valve Proportional flow control, normally closed, poppet 6L/min (4 USgpm) 8 bar (4 psi) EPV6A EPV6 Operation A style (nose in, side out) - In the de-energized position this valve remains closed from port to port. When current is applied to the coil, a controlled increasing flow will be allowed from port to port, in proportion to the current applied. style (side in, nose out) - in the de-energized position the valve remains closed from port to port. When current is applied to the coil, a controlled increasing flow will be allowed from port to port. In both examples free reverse flow is allowed in the opposite direction. Features Hardened and ground working parts. 8 bar working pressure, very low hysterisis, long life. Sectional View Description This is a way normally closed, pressure compensated, poppet type, electro proportional screw in cartridge valve with a low hysterisis and fine control. The valve is suitable for demanding applications where long life and accuracy is demanded Performance Data Ratings and Specifications Performance data is typical with fluid at,8 cst (5 SUS) and 49 C ( F) Typical application pressure (all ports) 8 bar (4 psi) Cartridge fatigue pressure (infinite life) 8 bar (4 psi) NFPA rated Rated flow to 6 L/min (4 USgpm) Internal leakage EPV6A 5 cm 3 /min, 4 bar ( psi) EPV6 cm 3 /min, 4 bar ( psi) Oil viscosity range -8 cst Nominal supply voltage /4 VDC Threshold current Adj from 35-6 ma ( VDC) Adj from 75-5 ma (4 VDC) Coil current for maximum flow.7 4 VDC.4 VDC Recommended PWM frequency - Hz application dependent, 5 Hz typ Power consumption V-.8 watts 4V-.8 watts Coil resistance v-6.5 /4V-5. Temperature range -3 to 9 C (- to 94 F) Cavity C-6-3S (undercut) Fluids Antiwear hydraulic oils with una-n seals (standard) Phosphate esters (non-alkyl) with Viton Filtration 7- bar (-3 psi) Cleanliness code 7/5/ + bar (3+ psi) Cleanliness code 5/3/ Housing material (standard) Aluminum or steel Typical hysterisis less than 4% of rated bar pressure drop-pulse width modulated (PWM) Weight cartridge only kg (. lbs) Seal kit Viton is a registered trademark of E.I. DuPont (una-n) -.A An Eaton rand

13 EPV6 - Proportional Valve Proportional flow control, normally closed, poppet 6L/min (4 USgpm) 8 bar (4 psi) Pressure Drop Curves Command Current V 4V A- 6 ma 3mA - 7 ma 35mA C- 8 ma 4mA D- 9 ma 45mA E- ma 5mA F- ma 55mA G- ma 6mA H- 3 ma 65mA I- 4 ma 7mA Pressure Differential A- bar 5 psi - bar 3 psi C- 5 bar 7 psi D- bar 5 psi E- bar 3 psi Pressure L/min (3 USgpm) Pressure Drop P On Stroke Off Stroke Delay/Reach 9% Delay/Reach 9% bar (9 psi) 4 ms/35 ms 5 ms/5 ms bar (45 psi) 4 ms/7 ms 5 ms/7 ms An Eaton rand -.A

14 EPV6A Dimensions Dimensions mm (inch) Cartridge Only - EPV6A Valves are shown with U coil. See Section C for coil information. Torque cartridge in aluminum housing 8- Nm (8-9 ft. lbs) Torque cartridge in steel housing Nm (- ft. lbs) Nose-in, side out 7,3 (.7) 9, (5.7) Ø 43,5 (.7) 4,7 (4.9) Note: When stand alone housings are used, the following guidelines apply: EPV6-A: Port 3 is to be plugged. EPV6-: Port 3 is to be connected to port in order to provide the required feedback flow path. 85,3 (7.9) 67,9 (.67) 8, (7.).3" - Thd. Screw type actuator (shown) 3 mm hex socket With manual actuator 38, Hex (.5) Ø 5,4 (.) No manual actuator Installation Drawing (Steel) 9.7 (5.7).5 (.6) 38. (.5) 3. (.9) Port LS SAE 4-Plugged X Ø8.74 (.344).7 (.5) (3.).8 (3.97) 79.4 (3.3).8 (3.97) 3. (.9) 38. (.5) -.A An Eaton rand

15 EPV6 Dimensions Dimensions mm (inch) Cartridge Only - EPV6 For EPV6- (flow to ), Port 3 must be connected to Port externally to the cartridge, either by passages in the cavity block or external plumbing. When purchased with undercut body, this connection is included in the body and Port 3 is not machined. A separate external port connection is not required for EPV6-A (flow to ). Side-in, nose out 7,3 (.7) Ø 43,5 (.7) Required external connection with standard C-6-3S cavity. 9, (5.7) 4,7 (4.9) 85,3 (7.9) 67,9 (.67) 8, (7.) Screw type actuator (shown) 3 mm hex socket 3 3.3"- Thd. 3 38, Hex (.5) Ø 5,4 (.) Ø 8,6 (.) With manual actuator No manual actuator Installation Drawing (Steel) 9.7 (5.7).5 (.6) 63.5 (.5) 3. (.9) 6.33 (.375) Port LS SAE 4-Plugged X Ø8.74 (.344).7 (.5) (3.).8 (3.97) 79. (3.).8 (3.97) 3. (.9) 38. (.5) An Eaton rand -3.A

16 EPV6 - Proportional Valve Dimensions EPV6-A-**-S-5C-**-D-(*)-*- CETOP 5 Interface mm (inch) 76, (.9) Required for removal 9,7 (8.65) 99,5 (3.9).5- UNC x.5" socket head cap screw (olt Kit 55634) M6 x 6 socket head cap screw (olt Kit 68963) 7,6 (.8) 69,5 (.74) 6, (.38) 5, (.) ISO-44-AC-5-4-A (NFPA D5) mounting surface,8 (.89) P? A,7 (.46) Tb Ta P A Ta Tb Ø 6,96/6,85? thru 4 holes EPV6--**-S-5C-**-D-(*)-*- CETOP 5 Interface mm (inch) P A Tb Ta 5, (.) 7,6 (.8) 69,5 (.74) 6, (.38).5- UNC x.5" socket head cap screw (olt Kit 55634) M6 x 6 socket head cap screw (olt Kit 68963) 76, (.9) Required for removal 9,7 (8.65) 99,5 (3.9) ISO-44-AC-5-4-A (NFPA D5) mounting surface,8 (.89) P,7 (.46) Note CETOP 5 Seal Kit Tb? A Ta Ø 6,96/6,85 thru 4 holes -4.A An Eaton rand

17 EPV6 - Proportional Valve Proportional flow control, NC, poppet 6L/min (4 USgpm) 8 bar (4 psi) Model Code EPV 6 * ** * ** ** *** * * ** Function EPV - Solenoid valve Size 6-6 size 3 Flow Direction A - Nose-in, side-out - Side-in, nose-out 4 Rated Flow 4-4 L/min (.5 USgpm) 6-6 L/min (6 USgpm) - L/min (6 USgpm) 6-6 L/min (4 USgpm) 6 Port Size Code Port Size Housing Number Aluminium Steel EPV6-A EPV6- EPV6-A EPV6- Cartridge only 4G /" SPP G 3/4" SPP H SAE H SAE T SAE T SAE C CETOP5 (NFPA D5) Interface (Requires steel body) See section J for housing details. 5 Valve Housing Material Omit for cartridge only A - Aluminum S - Steel Note: Aluminum housings can be used for pressures up to bar (3 psi). Steel housing must be used for operating pressures above bar 3 psi). 7 Seal Material N - una-n V - Viton NF - una-n and 6 mesh filter screen VF - Viton and 6 mesh filter screen 8 Voltage Rating D - VDC 4D - 4VDC 9 Manual Override Option lank - No manual override M - Pin type S - Screw type Manual override is available in two different configurations, either push pin type is used when system pressure does not exceed bar (3 psi). The screw type can be used at any system pressure. Note: When using the Screw Type override, care must be taken to return the override back to its neutral position before activating the valve. Failure to take this precaution may result in personal injury or damage to the machine. Connector Type lank - No coil F - Weatherpack male Q - Spade Terminals (DC only) W - Flying Lead N - Deutsch DT4-P Y - Metripack 5 male* U - DIN 4365 *Preferred Packard connector. For coil part numbers and dimensions see section C. Special Features - None M - Pin type S - Screw type WARNING When using the Screw Type override, care must be taken to return the override back to its neutral position before activating the valve. Failure to take this precaution may result in personal injury or damage to the machine. CAUTION A separate check valve is required down stream to isolate the EPV valve from load forces when the EPV is used to hold a load. An Eaton rand -5.A

18 ESV-8-C - Proportional Valve Proportional flow control, normally closed, poppet Up to 3 L/min (8 USgpm) bar (3 psi) Operation In the de-energized position, this valve blocks flow from port to port and free flow is allowed from port to port. In the energized position, flow from port to port is restricted while free flow is allowed from port to port. The valve flow is proportional to the current applied to the coil. Features Hardened and ground working parts to give long life and very low leakage. IP69K Tough coil compatibility, continuously rated. Compact design with low pressure drop. Sectional View Performance Data Ratings and Specifications Performance data is typical with fluid at,8 cst (5 SUS) and 49 C ( F) Typical application pressure bar (3 psi) Cartridge endurance rating million cycles Cartridge fatigue pressure rating (NFPA/T.6. R-) bar (3 psi) Rated 5 psid, 3 L/min (8.4 gpm) min, 35 L/min (9.3 gpm) nom Leakage (fully closed) 5 drops/min 3 psi Nominal supply voltage /4 VDC Current to open valve ma (V coil), ma (4V coil) Temperature range -3 to 9 C (- to 94 F) Maximum oil temperature C (48 F) Maximum internal oil temperature C (39 F) Cavity C-8- Fluids All general purpose hydraulic fluids such as: MIL-H-566, SAE, SAE, etc. Filtration Cleanliness code 8/6/3 Housing material (standard) Aluminum Hysterisis 3.8 L/min ( Usgpm) with dither Weight cartridge only. kg (.4 lbs) Seal kit (una-n), (Viton ) Viton is a registered trademark of E.I. DuPont Description This is a way position, pilot operated poppet type, normally closed, proportional flow control screw in cartridge valve. Ideal for lowering circuits or in conjunction with pressure compensators to provide proportional flow control to any actuator. Pressure Drop Curves Flow - USgpm Pressure Drop - bar Pressure Drop - PSID Current - Amps Flow - L/min Flow - USgpm Flow - L/min -3.A An Eaton rand

19 ESV-8-C - Proportional Valve Proportional flow control, normally closed, poppet Up to 3 L/min (8 USgpm) bar (3 psi) Model Code ESV 8 * C * ** ** * * * ** ** Function ESV - Proportional flow control Size 8-8 size 3 Seal Material N - una-n V - Viton 4 Style C - Normally open 5 Housing Material lank - Cartridge only A - Aluminum 6 Port Size Coil Series Code Port Size Housing Number lank - No coil S - S Series, W Aluminium For coil part numbers and dimensions Cartridge only see section C. G /4" SPP G 3/8" SPP -678 Coil Special Features 4T SAE lank - No coil 6T SAE No special feature 8T SAE See section J for housing details. 7 Coil Voltage - No coil D - VDC 4D - 4VDC 8 Type of Power lank - No coil D - DC w/o diode - DC w/o diode 9 Connector Type lank - No coil G - ISO 44 DIN 4365 Q - Spade Terminals W - Flying Lead N - Deutsch (DC only) Y - Amp JR (DC only) P - Conduit For coil part numbers and dimensions see section C. Valve Special Features lank - None Dimensions mm (inch) Cartridge Only Installation Drawing 9, HEX (.75) 5.5 (.7) 9. (.75) 5,5 (.7), HEX (.875) 6, (.3) 38. (.5) X (.8) (.) 5.5 (.6) 7,8 (.9),75-6 THD. 3.4 (.3) 44. (.73) 5.8 (.) Ø,6 (.497) Ø 3,8 (.5) An Eaton rand -3.A

20 ESV--C - Proportional Valve Proportional flow control, normally closed, poppet Up to 7 L/min (8.5 USgpm) bar (3 psi) Operation In the de-energized position, this valve blocks flow from port to port and free flow is allowed from port to port. In the energized position, flow from port to port is restricted while free flow is allowed from port to port. The valve flow is proportional to the current applied to the coil. Features Hardened and ground working parts to give long life and very low leakage. IP69K Tough coil compatibility, continuously rated. Compact design with low pressure drop. Sectional View Performance Data Ratings and Specifications Performance data is typical with fluid at,8 cst (5 SUS) and 49 C ( F) Typical application pressure bar (3 psi) Cartridge endurance rating million cycles Cartridge fatigue pressure rating (NFPA/T.6. R-) bar (3 psi) Rated 5 psid, 7 L/min (8.5 gpm) min, 74 L/min (9.4 gpm) nom Leakage (fully closed) 5 drops/min 3 psi Nominal supply voltage /4 VDC Current to open valve 9- ma (V coil), 45-5 ma (4V coil) Temperature range -3 to 9 C (- to 94 F) Maximum oil temperature C (48 F) Maximum internal oil temperature C (39 F) Cavity C-- Fluids All general purpose hydraulic fluids such as: MIL-H-566, SAE, SAE, etc. Filtration Cleanliness code 8/6/3 Housing material (standard) Aluminum Hysterisis 3.8 L/min ( USgpm) with dither Weight cartridge only.3 kg (.8 lbs) Seal kit (una-n), (Viton ) Viton is a registered trademark of E.I. DuPont Description This is a way position, pilot operated poppet type, normally closed, proportional flow control screw in cartridge valve. Ideal for lowering circuits or in conjunction with pressure compensators to provide proportional flow control to any actuator. Pressure Drop Curves Flow - USgpm Pressure Drop At Max Poppet Opening Pressure Drop - PSID Flow - USgpm Flow vs. Current at 5 PSID Current - Amps -4.A An Eaton rand

21 ESV--C - Proportional Valve Proportional flow control, normally closed, poppet Up to 7 L/min (8.5 USgpm) bar (3 psi) Model Code ESV * C * ** *** * * * ** ** Function ESV - Proportional flow control Size - size 3 Seal Material lank - una-n V - Viton 4 Style C - Normally closed 6 Port Size Coil Series Code Port Size Housing Number lank - No coil J - J Series, W Aluminium For coil part numbers and dimensions Cartridge only see section C. 3 3/8" SPP T SAE Coil Special Features 3G 3/8" SPP lank - No coil 6H SAE No special feature 8H SAE See section J for housing details. Valve Special Features lank - None 5 Housing Material lank - Cartridge only A - Aluminum 7 Coil Voltage - No coil D - VDC 4D - 4VDC 8 Type of Power lank - No coil D - DC w/o diode - DC w/o diode 9 Connector Type lank - No coil G - ISO 44 DIN 4365 Q - Spade Terminals W - Flying Lead N - Deutsch (DC only) Y - Amp JR (DC only) P - Conduit For coil part numbers and dimensions see section C. Dimensions mm (inch) Cartridge Only Installation Drawing 9, HEX (.75) 59, (.33) 5.4 (.) 3,7 (.5) 5,4 HEX (.),875-4 THD. 34,6 (.36) X 7. (.8) 9.5 (.37) 63.5 (.5) 9. (.75) 63.5 (.5).8 (.8) Ø 5,8 (.6) Ø 38,9 (.53) An Eaton rand -4.A

22 ESV--C - Proportional Valve Proportional flow control, normally closed, poppet Up to 4 L/min (7.3 USgpm) bar (3 psi) Operation In the de-energized position, this valve blocks flow from port to port and free flow is allowed from port to port. In the energized position, flow from port to port is restricted while free flow is allowed from port to port. The valve flow is proportional to the current applied to the coil. Features Hardened and ground working parts to give long life and very low leakage. IP69K Tough coil compatibility, continuously rated. Compact design with low pressure drop. Sectional View Performance Data Ratings and Specifications Performance data is typical with fluid at,8 cst (5 SUS) and 49 C ( F) Typical application pressure bar (3 psi) Cartridge endurance rating million cycles Cartridge fatigue pressure rating (NFPA/T.6. R-) bar (3 psi) Rated 5 psid, 4 L/min (7.3 gpm) min, L/min (8.9 gpm) nom Leakage (fully closed) 5 drops/min 3 psi Nominal supply voltage /4 VDC Current to open valve 8-9 ma (V coil), 4-45 ma (4V coil) Temperature range -3 to 9 C (- to 94 F) Maximum oil temperature C (48 F) Maximum internal oil temperature C (39 F) Cavity C-- Fluids All general purpose hydraulic fluids such as: MIL-H-566, SAE, SAE, etc. Filtration Cleanliness code 8/6/3 Housing material (standard) Aluminum Hysterisis 3.8 L/min ( USgpm) with dither Weight cartridge only.3 kg (.48 lbs) Seal kit (una-n), (Viton ) Viton is a registered trademark of E.I. DuPont Description This is a way position, pilot operated poppet type, normally closed, proportional flow control screw in cartridge valve. Ideal for lowering circuits or in conjunction with pressure compensators to provide proportional flow control to any actuator. Pressure Drop Curves Flow - USgpm Pressure Drop At Max Poppet Opening Pressure Drop - PSID Flow - USgpm Flow vs. Current at 5 PSID Current - Amps -5.A An Eaton rand

23 ESV--C - Proportional Valve Proportional flow control, normally closed, poppet Up to 4 L/min (7.3 USgpm) bar (3 psi) Model Code ESV * C * **** *** * * * ** ** Function ESV - Proportional flow control Size - size 3 Seal Material lank - una-n V - Viton 4 Style C - Normally closed 5 Housing Material lank - Cartridge only A - Aluminum 6 Port Size 9 Connector Type Code Port Size Housing Number Aluminium Single lank - No coil G - ISO 44 DIN 4365 Q - Spade Terminals 3 Cartridge only W - Flying Lead 4G /" SPP -68 N - Deutsch (DC only) Y - Amp JR (DC only) 4GU /" SPP -66 P - Conduit 6G 3/4" SPP -67 For coil part numbers and dimensions 6GU 3/4" SPP -65 see section C. T SAE -664 TU SAE -664 T SAE TU SAE See section J for housing details. 7 Coil Voltage - No coil D - VDC 4D - 4VDC 8 Type of Power lank - No coil D - DC w/o diode - DC w/o diode Coil Series lank - No coil J - J Series, W For coil part numbers and dimensions see section C. Coil Special Features lank - No coil - No special feature Valve Special Features lank - None Dimensions mm (inch) Cartridge Only Installation Drawing 59, (.87) 9, HEX (.75).7 (.5) 7.9 (.87).7 (.5) 5.4 (.) 44,7 (.76) 3,8 HEX (.5).6 - THD. 34,6 (.36) 88.9 (3.5) 63.5 (.5) 88.9 (3.5) 63.5 (.5) X Ø.3 (.46) 8.7 (.3) Ø 3,75 (.935) Ø 38,9 (.53) An Eaton rand -5.A

24 ESV-8-O - Proportional Valve Proportional flow control, normally open, poppet Up to 3 L/min (8.4 USgpm) bar (3 psi) Operation In the de-energized position, this valve allows free flow from port to port and restricts flow from port to port. In the energized position, flow is blocked from port to port, and free flow is allowed from port to port. The valve flow is proportional to the current applied to the coil. Features Hardened and ground working parts to give long life and very low leakage. IP69K Tough coil compatibility, continuously rated. Compact design with low pressure drop. Sectional View Performance Data Ratings and Specifications Performance data is typical with fluid at,8 cst (5 SUS) and 49 C ( F) Typical application pressure (all ports) bar (3 psi) Cartridge endurance rating million cycles Cartridge fatigue pressure rating (NFPA/T.6. R-) bar (3 psi) Rated 5 psid, 3 L/min (8.4 gpm) min, 35 L/min (9.3 gpm) nom Leakage (fully closed) 5 drops/min, 3 psi Nominal supply voltage /4 VDC Current to fully close valve -5 ma (V coil), ma (4V coil) Temperature range -3 to 9 C (- to 94 F) Maximum oil temperature C (48 F) Maximum internal oil temperature C (39 F) Cavity C-8- Fluids All general purpose hydraulic fluids such as: MIL-H-566, SAE, SAE, etc. Filtration Cleanliness code 8/6/3 Housing material (standard) Aluminum Hysterisis 3.8 L/min ( USgpm) with dither Weight cartridge only. kg (.3 lbs) Seal kit (una-n), (Viton ) Viton is a registered trademark of E.I. DuPont Description This is a way position, pilot operated poppet type, normally open, proportional flow control screw in cartridge valve. Ideal for lowering circuits or in conjunction with pressure compensators to provide proportional flow control to any actuator. Pressure Drop Curves Flow - USgpm Pressure Drop - PSID Flow - USgpm Current - Amps -6.A An Eaton rand

25 ESV-8-O - Proportional Valve Proportional flow control, normally open, poppet Up to 3 L/min (8.4 USgpm) bar (3 psi) Model Code ESV 8 * O * ** *** * * * ** * Function ESV - Proportional flow control Size 8-8 size 3 Seal Material N - una-n V - Viton 4 Style O - Normally open 5 Housing Material lank - Cartridge only A - Aluminum 6 Port Size Coil Series Code Port Size Housing Number Aluminium lank - No coil S - S Series, W For coil part numbers and dimensions Cartridge only see section C. 3G 3/8" SPP T SAE T SAE T SAE See section J for housing details. 7 Coil Voltage - No coil D - VDC 4D - 4VDC 8 Type of Power lank - No coil D - DC w/o diode - DC w/o diode 9 Connector Type lank - No coil G - ISO 44 DIN 4365 Q - Spade Terminals W - Flying Lead N - Deutsch (DC only) Y - Amp JR (DC only) P - Conduit For coil part numbers and dimensions see section C. Coil Special Features lank - No coil - No special feature Valve Special Features lank - None Dimensions mm (inch) Cartridge Only Installation Drawing 9, HEX (.75) 64.3 (.53) 9. (.75) 9. (.75) 64,3 (.53) 7,8 (.9), HEX (.87),75-6 THD 6, (.3) 38. (.5) X (.8) (.) 3.4 (.3) 44. (.73) 5.8 (.) 5.5 (.6) Ø,6 (.497) Ø 3,8 (.5) An Eaton rand -6.A

26 ESV--O - Proportional Valve Proportional flow control, normally open, poppet Up to 7 L/min (8.5 USgpm) bar (3 psi) Operation In the de-energized position, this valve allows free flow from port to port and restricts flow from port to port. In the energized position, flow is blocked from port to port, and free flow is allowed from port to port. The valve flow is proportional to the current applied to the coil. Features Hardened and ground working parts to give long life and very low leakage. IP69K Tough coil compatibility, continuously rated. Compact design with low pressure drop. Sectional View Performance Data Ratings and Specifications Performance data is typical with fluid at,8 cst (5 SUS) and 49 C ( F) Typical application pressure bar (3 psi) Cartridge endurance rating million cycles Cartridge fatigue pressure rating (NFPA/T.6. R-) bar (3 psi) Rated 5 psid, 7 L/min (8.5 gpm) min, 74 L/min (9.4 gpm) nom Leakage (fully closed) 5 drops/min, 3 psi Nominal supply voltage /4 VDC Current to fully close valve - ma (V coil), 5-6 ma (4V coil) Temperature range -3 to 9 C (- to 94 F) Maximum oil temperature C (48 F) Maximum internal oil temperature C (39 F) Cavity C-- Fluids All general purpose hydraulic fluids such as: MIL-H-566, SAE, SAE, etc. Filtration Cleanliness code 8/6/3 Housing material (standard) Aluminum Hysterisis 3.8 L/min ( USgpm) with dither Weight cartridge only.4 kg (.3 lbs) Seal kit (una-n), (Viton ) Viton is a registered trademark of E.I. DuPont Description This is a way position, pilot operated poppet type, normally open, proportional flow control screw in cartridge valve. Ideal for lowering circuits or in conjunction with pressure compensators to provide proportional flow control to any actuator. Pressure Drop Curves Flow - USgpm Current - Amps Pressure Drop - PSID Flow - USgpm -7.A An Eaton rand

27 ESV--O - Proportional Valve Proportional flow control, normally open, poppet Up to 7 L/min (8.5 USgpm) bar (3 psi) Model Code ESV * O * ** *** * * * ** ** Function ESV - Proportional flow control Size - size 3 Seal Material N - una-n V - Viton 6 Port Size Coil Series Code Port Size Housing Number lank - No coil J - J Series, W Aluminium For coil part numbers and dimensions Cartridge only see section C. 3G 3/8" SPP H SAE Coil Special Features 8H SAE lank - No coil See section J for housing details. - No special feature 4 Style C - Normally closed 5 Housing Material lank - Cartridge only A - Aluminum 7 Coil Voltage - No coil - VDC 4-4VDC 8 Type of Power lank - No coil D - DC w/o diode - DC w/o diode 9 Connector Type lank - No coil G - ISO 44 DIN 4365 Q - Spade Terminals W - Flying Lead N - Deutsch (DC only) Y - Amp JR (DC only) P - Conduit For coil part numbers and dimensions see section C. Valve Special Features lank - None Dimensions mm (inch) Cartridge Only Installation Drawing 9, HEX (.75) 7,3 (.77) 5.4 (.) X 7. (.8) 63.5 (.5).8 (.8) 3,7 (.5) 5,4 HEX (.),875-4 THD. 34,6 (.36) 9.5 (.37) 63.5 (.5) 9. (.75) Ø 5,8 (.6) Ø 38,9 (.53) An Eaton rand -7.A

28 ESV--O - Proportional Valve Proportional flow control, normally open, poppet Up to 4 L/min (7.3 USgpm) bar (3 psi) Operation In the de-energized position, this valve allows free flow from port to port and restricts flow from port to port. In the energized position, flow is blocked from port to port, and free flow is allowed from port to port. The valve flow is proportional to the current applied to the coil. Features Hardened and ground working parts to give long life and very low leakage. IP69K Tough coil compatibility, continuously rated. Compact design with low pressure drop. Sectional View Performance Data Ratings and Specifications Performance data is typical with fluid at,8 cst (5 SUS) and 49 C ( F) Typical application pressure bar (3 psi) Cartridge endurance rating million cycles Cartridge fatigue pressure rating (NFPA/T.6. R-) bar (3 psi) Rated 5 psid, 4 L/min (7.3 gpm) min, L/min (8.9 gpm) nom Leakage (fully closed) 5 drops/min 3 psi Nominal supply voltage /4 VDC Current to fully close valve 8-9 ma (V coil), 4-45 ma (4V coil) Temperature range -3 to 9 C (- to 94 F) Maximum oil temperature C (48 F) Maximum internal oil temperature C (39 F) Cavity C-- Fluids All general purpose hydraulic fluids such as: MIL-H-566, SAE, SAE, etc. Filtration Cleanliness code 8/6/3 Housing material (standard) Aluminum Hysterisis 3.8 L/min ( USgpm) with dither Weight cartridge only. kg (.3 lbs) Seal kit (una-n), (Viton ) Viton is a registered trademark of E.I. DuPont Description This is a way position, pilot operated poppet type, normally open, proportional flow control screw in cartridge valve. Ideal for lowering circuits or in conjunction with pressure compensators to provide proportional flow control to any actuator. Pressure Drop Curves Flow - USgpm Pressure Drop - PSID Flow - USgpm Current - Amps -8.A An Eaton rand

29 ESV--O - Proportional Valve Proportional flow control, normally open, poppet Up to 4 L/min (7.3 USgpm) bar (3 psi) Model Code ESV * O * ** ** * * * ** ** Function ESV - Proportional flow control Size - size 3 Seal Material lank - una-n V - Viton 4 Style O - Normally open 5 Housing Material lank - Cartridge only A - Aluminum 6 Port Size 9 Connector Type Code Port Size Housing Number Aluminium lank - No coil G - ISO 44 DIN 4365 Q - Spade Terminals Cartridge only W - Flying Lead 6G 3/4" SPP -67 N - Deutsch (DC only) Y - Amp JR (DC only) 6GU 3/4" SPP -65 P - Conduit T SAE -664 For coil part numbers and dimensions TU SAE -664 see section C. T SAE TU SAE See section J for housing details. 7 Coil Voltage - No coil - VDC 4-4VDC 8 Type of Power lank - No coil D - DC w/o diode - DC w/o diode Coil Series lank - No coil J - J Series, W For coil part numbers and dimensions see section C. Coil Special Features lank - No coil - No special feature Valve Special Features lank - None Dimensions mm (inch) Cartridge Only Installation Drawing 7, (.87) 9, HEX (.75).7 (.5) 7.9 (.87).7 (.5) 5.4 (.) 44,7 (.76) 3,8 HEX (.5).6 - THD. 34,6 (.36) 88.9 (3.5) 63.5 (.5) 88.9 (3.5) 63.5 (.5) X Ø.3 (.46) 8.7 (.3) Ø 3,75 (.935) Ø 38,9 (.53) An Eaton rand -8.A

30 EFV--C - Proportional Valve Proportional flow, normally closed, poppet Up to 38 L/min ( USgpm) bar (3 psi) 3 Sectional View Operation The valve is controlled by current supplied to the coil. At zero current, the valve is fully closed from port 3 to port. At 5 ma (V coil) the valve is considered fully open. This is the maximum intended current level for use in applications. Port is used for pressure balancing the spool and armature and must be blocked in all cases. The maximum intended pressure drop is 3 PSID. At pressure drops above 3 PSID, almost no increase in flow is obtained. The intended flow direction is from port 3 to port. Operation of the valve with flow from port to port 3 will produce flow vs current and flow vs pressure drop curves that are significantly different from those obtained with flow from port 3 to port. Since the spool and armature are pressure balanced, the operating pressure does not affect the operating characteristics of the valve. The operating point of the valve is determined only by current, pressure drop and temperature. Features Hardened and ground working parts to give long life with good control; Compact design with low pressure drop.ip69k Tough coil compatibility, continuously rated. Description 3 This is a way position, pilot operated spool type, normally closed, proportional flow control screw in cartridge valve. Ideal for speed control and in conjunction with pressure compensators to provide proportional pressure compensated flow control to any actuator. Performance Data Ratings and Specifications Performance data is typical with fluid at,8 cst (5 SUS) and 49 C ( F) Typical application pressure Cartridge endurance rating Cartridge fatigue pressure (infinite life) Rated flow bar (3 psi) million cycles bar (3 psi) NFPA rated Flow rating A 5. L/min (4 USgpm) Flow rating 3. L/min (8 USgpm) Flow rating C 37.9 L/min ( USgpm) Internal leakage 97 cm 3 /min (in 3 3 PSID Nominal supply voltage /4 V Current to fully close valve 5-6 ma (V coil), 75-8 ma (4V coil) Recommended PWM frequency -4 Hz Coil resistance 4.7v /V, 9. /4V Mass Cartridge only,37 kg (.8 lb), cartridge with coil and end nut,73 kg (.6 lb) Temperature range -3 to 9 C (- to 94 F) Maximum oil temperature C (48 F) Maximum internal coil temperature C (39 F) Cavity C--3 Fluids All general purpose hydraulics fluids such as: MIL-H-566, SAE, SAE, DTE 4, etc. Filtration Cleanliness code 8/6/3 Housing material (standard) Aluminum or steel Hysterisis USgpm with 4Hz PWM driver Seal kit 995- (una-n), 996- (Viton ) Viton is a registered trademark of E.I. DuPont -9.A An Eaton rand

31 EFV--C - Proportional Valve Proportional flow, normally closed, poppet Up to 38 L/min ( USgpm) bar (3 psi) Pressure Drop Curves Pressure Drop - bar Flow - USgpm Pressure Drop - PSID Flow - L/min Flow - USgpm Pressure Drop - bar Pressure Drop - PSID Flow - L/min Flow - USgpm Pressure Drop - bar Pressure Drop - PSID Note: To determine operating characteristics for the flow rating selected, at a specific differential pressure, first determine maximum flow from upper curve at the differential pressure value. This will be the % flow on the lower curve. Flow - L/min Flow % Current - ma Parameters: 4 Hz PWM An Eaton rand -9.A

32 EFV--C - Proportional Valve Proportional flow, normally closed, poppet Up to 38 L/min ( USgpm) bar (3 psi) Model Code EFV * C * * * *** *****E** Function EFV - Electro proportional flow control valve Size - size 3 Seal Material N - una-n V - Viton 4 Logic C - Normally closed 5 Flow Rating A PSID PSID C - 6 PSID 6 Manual Override Option - No core tube special features S - Screw-in 8 Port Size Code Port Size Housing Number Cartridge only Aluminium Single 3 3/8" SPP * Steel Single 6T SAE * T SAE G /4" SPP G 3/8" SPP H SAE H SAE Note: oth the manifold and port plug are required. See section J for housing details. *Aluminum Light duty. 7 Valve Housing Material lank - Cartridge only A - Aluminum S - Steel 9 Coil Series E - E series coils *These model digits will not be stamped on the valve. For coil part numbers and dimensions see section C. Special Features - None Only required when valve has special features, omitted if. -9.A An Eaton rand

33 EFV--C - Proportional Valve Proportional flow, normally closed, poppet Up to 38 L/min ( USgpm) bar (3 psi) Dimensions mm (inch) Torque cartridge in housing S Nm (5-55 ft lbs) A Nm (35-4 ft lbs) Note: S type manual override shown. DIN 4365 connector shown. Note: Port is unused and must be plugged. Cartridge Only 44, (.74) 3,8 (.9) 3, (.6) 9, (.75) 86,4 (3.4) 8,7 (4.8) 64, (.5) 47, (.86) 3 Installation Drawing (Aluminum) 86.4 (3.4) 4,6 (.97) 5,4 (.) 8,8 (.74) 57. (.5) 3 X7,4 (.8) 34,8 (.37) 75,4 (.97) 5 (.97) 9.5 (.38) 57.5 (.5) 75.4 (.97) An Eaton rand -93.A

34 EFV--C - Proportional Valve Proportional flow, normally closed spool Up to 77 L/min (.6 USgpm) bar (3 psi) 3 Sectional View Operation The valve is controlled by current supplied to the coil. At zero current, the valve is fully closed from port 3 to port. At 5 ma (V coil) the valve is considered fully open. This is the maximum intended current level for use in applications. Port is used for pressure balancing the spool and armature and must be blocked in all cases. The maximum intended pressure drop is 3 PSID. At pressure drops above 3 PSID, almost no increase in flow is obtained. The intended flow direction is from port 3 to port. Operation of the valve with flow from port to port 3 will produce flow vs current and flow vs pressure drop curves that are significantly different from those obtained with flow from port 3 to port. Since the spool and armature are pressure balanced, the operating pressure does not affect the operating characteristics of the valve. The operating point of the valve is determined only by current, pressure drop and temperature. Features Hardened and ground working parts to give long life with good control; Compact design with low pressure drop.ip69k Tough coil compatibility, continuously rated. Description This is a way position, pilot operated spool type, normally closed, proportional flow control screw in cartridge valve. Ideal for speed control and in conjunction with pressure compensators to provide proportional pressure compensated flow control to any actuator. 3 Performance Data Ratings and Specifications Performance data is typical with fluid at,8 cst (5 SUS) and 49 C ( F) Typical application pressure bar (3 psi) Cartridge endurance rating million cycles Cartridge fatigue pressure (infinite life) bar (3 psi) NFPA rated Rated flow Flow rating A 55 L/min (4.3 USgpm) Flow rating 77 L/min (.6 USgpm) Internal leakage (fully closed) cm 3 /min (5-3 in 3 bar (3 PSID) Nominal supply voltage /4 V Current to fully close valve 5-6 ma (V coil), 75-8 ma (4V coil) Recommended dither frequency -4 Hz Coil resistance 4.7v /V, 9. /4V Mass Cartridge only,37 kg (.8 lb), cartridge with coil and end nut,73 kg (.6 lb) Temperature range -3 to 9 C (- to 94 F) Maximum oil temperature C (48 F) Maximum internal coil temperature C (39 F) Cavity C--3 Fluids All general purpose hydraulics fluids such as: MIL-H-566, SAE, SAE, DTE 4, etc. Filtration Cleanliness code 8/6/3 Housing material (standard) Aluminum or steel Hysterisis USgpm with 4Hz PWM driver Seal kit 997- (una-n), 997- (Viton ) Viton is a registered trademark of E.I. DuPont -.A An Eaton rand

35 EFV--C - Proportional Valve Proportional flow, normally closed spool Up to 77 L/min (.6 USgpm) bar (3 psi) Pressure Drop Curves Note: To determine operating characteristics for the flow rating selected, at a specific differential pressure, first determine maximum flow from upper curve at the differential pressure value. This will be the % flow on the lower curve. Parameters: 4 Hz PWM An Eaton rand -.A

36 EFV--C - Proportional Valve Proportional flow, normally closed spool Up to 77 L/min (.6 USgpm) bar (3 psi) Model Code EFV * C * * * *** *****E** Function EFV - Electro proportional flow control valve Size - size 6 Manual Override Option - No core tube special features S - Screw-in 8 Port Size 7 Valve Housing Material lank - Cartridge only A - Aluminum S - Steel 9 Coil Series E - E series coils *These model digits will not be stamped on the valve. For coil part numbers and dimensions see section C. 3 Seal Material N - una-n V - Viton 4 Logic C - Normally closed 5 Flow Rating A PSID PSID Code Port Size Housing Number Cartridge only Aluminium Single Steel Single 4G /" SPP G 3/4" SPP T SAE T SAE Note: oth the manifold and port plug are required. See section J for housing details. Special Features - None Only required when valve has special features, omitted if. -.A An Eaton rand

37 EFV--C - Proportional Valve Proportional flow, normally closed spool Up to 77 L/min (.6 USgpm) bar (3 psi) Dimensions mm (inch) Torque cartridge in steel housing S Nm (- ft lbs) A - 8- Nm (8-9 ft lbs) Note: Port is unused and must be plugged. Note: EFV- with DIN-4365 connector shown. Cartridge Only Installation Drawing (Aluminum) 44, (.74) 3,8 (.9) 9, (.75) 5.4 (.) (.46).7 (.5) 5.4 (.) 86,3 (3.4) 64, (.5) 8.7 (.3) 3 8 (4.5) 8.55 (3.5) 44.5 (.75) 76. (3.) 88.9 (3.5) 5.6 (.3).6 68,6 (.7) 3 An Eaton rand -3.A

38 EFV--O - Proportional Valve Proportional flow, normally open, poppet Up to 38 L/min ( USgpm) bar (3 psi) 3 Operation The valve is controlled by current supplied to the coil. At zero current, the valve is fully open from port to port 3. At 5 to 6 ma (V coil) the valve is fully closed. Port is used for pressure balancing the spool and armature and must be blocked in all cases. The maximum intended pressure drop is 3 PSID. At pressure drops above 3 PSID, almost no increase in flow is obtained. The intended flow direction is from port to port 3. Operation of the valve with flow from port 3 to port will produce flow vs current and flow vs pressure drop curves that are significantly different from those obtained with flow from port to port 3. Since the spool and armature are pressure balanced, the operating pressure does not affect the operating characteristics of the valve. The operating point of the valve is determined only by current, pressure drop and temperature. Features Hardened and ground working parts to give long life with good control; Compact design with low pressure drop.ip69k Tough coil compatibility, continuously rated. Sectional View 3 Performance Data Ratings and Specifications Performance data is typical with fluid at,8 cst (5 SUS) and 49 C ( F) Typical application pressure Cartridge endurance rating Cartridge fatigue pressure (infinite life) Rated flow bar (3 psi) million cycles bar (3 psi) NFPA rated Flow rating A 5. L/min (4 USgpm) Flow rating 3. L/min (8 USgpm) Flow rating C 37.9 L/min ( USgpm) Internal leakage 97 cm 3 /min (in 3 (3 PSID) Nominal supply voltage /4 V Current to fully close valve 5-6 ma (V coil), 75-8 ma (4V coil) Recommended PWM frequency -4 Hz Coil resistance 4.7v /V, 9. /4V Mass Cartridge only,37 kg (.8 lb), cartridge with coil and end nut,73 kg (.6 lb) Temperature range -3 to 9 C (- to 94 F) Maximum oil temperature C (48 F) Maximum internal coil temperature C (39 F) Cavity C--3 Fluids All general purpose hydraulics fluids such as: MIL-H-566, SAE, SAE, DTE 4, etc. Filtration Cleanliness code 8/6/3 Housing material (standard) Aluminum or steel Hysterisis USgpm with 4Hz PWM driver Seal kit 995- (una-n), 996- (Viton ) Viton is a registered trademark of E.I. DuPont Description This is a way position, pilot operated spool type, normally open, proportional flow control screw in cartridge valve. Ideal for speed control and in conjunction with pressure compensators to provide proportional pressure compensated flow control to any actuator. Pressure Drop Curves USgpm Flow Pressure Drop - PSID L/min Flow - USgpm Flow Pressure Drop - PSID L/min Flow - -.A An Eaton rand

39 Flow % EFV--O - Proportional Valve Performance Curves Max. Flow vs Pressure Drop Flow rating "A" (Valve fully open) Max. Flow vs Pressure Drop Flow rating "" (Valve fully open) USgpm Flow - Pressure Drop - bar Pressure Drop - PSID L/min Flow - USgpm Flow - Pressure Drop - bar Pressure Drop - PSID L/min Flow - Max. Flow vs Pressure Drop Flow rating "C" (Valve fully open) Flow vs. Current USgpm Flow - Pressure Drop - bar Pressure Drop - PSID L/min Flow Note: To determine operating characteristics for the flow rating selected, at a specific differential pressure, first determine maximum flow from upper curve at the differential pressure value. This will be the % flow flow on the lower curve. Current - ma Parameters: 4 Hz PWM An Eaton rand -.A

40 EFV--O - Proportional Valve Proportional flow, normally open, poppet Up to 38 L/min ( USgpm) bar (3 psi) Model Code EFV * * * * *** *****E** Function EFV - Electro proportional flow control valve Size - size 3 Seal Material N - una-n V - Viton 4 Logic - Normally open 5 Flow Rating A PSID PSID C - 6 PSID 6 Manual Override Option - No core tube special features S - Screw-in 8 Port Size Code Port Size Housing Number Cartridge only Aluminium Single 3 3/8" SPP * Steel Single 6T SAE * T SAE G 3/8" SPP H SAE H SAE Note: oth the manifold and port plug are required. See section J for housing details. *Aluminum Light duty. 7 Valve Housing Material lank - Cartridge only A - Aluminum S - Steel 9 Coil Series E - E series coils *These model digits will not be stamped on the valve. For coil part numbers and dimensions see section C. Special Features - None Only required when valve has special features, omitted if. -.A An Eaton rand

41 EFV--O - Proportional Valve Proportional flow, normally open, poppet Up to 38 L/min ( USgpm) bar (3 psi) Dimensions mm (inch) Cartridge Only Torque cartridge in housing S Nm (5-55 ft lbs) A Nm (35-4 ft lbs) Note: S type manual override shown. DIN 4365 connector shown. Note: Port is unused and must be plugged. 44, (.74) 3,8 (.9) 3, (.6) 9, (.75) 86,4 (3.4) 8,7 (4.8) 64, (.5) 47, (.86) 3 Installation Drawing (Aluminum) 86.4 (3.4) 4,6 (.97) 5,4 (.) 8,8 (.74) 57. (.5) 3 X7,4 (.8) 34,8 (.37) 75,4 (.97) 5 (.97) 9.5 (.38) 57.5 (.5) 75.4 (.97) An Eaton rand -3.A

42 EFV--O - Proportional Valve Proportional flow, normally open spool Up to 4 L/min (7.5 USgpm) bar (3 psi) 3 Sectional View Operation The valve is controlled by current supplied to the coil. At zero current, the valve is fully open from port to port 3. At 5 to 6 ma (V coil) the valve is fully closed. Port is used for pressure balancing the spool and armature and must be blocked in all cases. The maximum intended pressure drop is 3 PSID. At pressure drops above 3 PSID, almost no increase in flow is obtained. The intended flow direction is from port to port 3. Operation of the valve with flow from port 3 to port will produce flow vs current and flow vs pressure drop curves that are significantly different from those obtained with flow from port to port 3. Since the spool and armature are pressure balanced, the operating pressure does not affect the operating characteristics of the valve. The operating point of the valve is determined only by current, pressure drop and temperature. Features Hardened and ground working parts to give long life with good control; Compact design with low pressure drop.ip69k Tough coil compatibility, continuously rated. Description 3 This is a way position, pilot operated spool type, normally open, proportional flow control screw in cartridge valve. Ideal for speed control and in conjunction with pressure compensators to provide proportional pressure compensated flow control to any actuator. Performance Data Ratings and Specifications Performance data is typical with fluid at,8 cst (5 SUS) and 49 C ( F) Typical application pressure bar (3 psi) Cartridge endurance rating million cycles Cartridge fatigue pressure (infinite life) bar (3 psi) NFPA rated Rated flow Flow rating A 95 L/min (5 USgpm) Flow rating 4 L/min (7.5 USgpm) Internal leakage (fully closed) cm 3 /min (5-3 in 3 bar (3 PSID) Nominal supply voltage /4 V Current to fully close valve 5-6 ma (V coil), 75-8 ma (4V coil) Recommended PWM frequency -4 Hz Coil resistance 4.7v /V, 9. /4V Mass Cartridge only,37 kg (.8 lb), cartridge with coil and end nut,73 kg (.6 lb) Temperature range -3 to 9 C (- to 94 F) Maximum oil temperature C (48 F) Maximum internal coil temperature C (39 F) Cavity C--3 Fluids All general purpose hydraulics fluids such as: MIL-H-566, SAE, SAE, etc. Filtration Cleanliness code 8/6/3 Housing material (standard) Aluminum or steel Hysterisis USgpm with 4Hz PWM driver Seal kit 997- (una-n), 997- (Viton ) Viton is a registered trademark of E.I. DuPont -.A An Eaton rand

43 Flow % EFV--O - Proportional Valve Performance Curves Max. Flow vs Pressure Drop Flow rating A (Zero Current) Max. Flow vs Pressure Drop Flow rating (Zero Current) Flow - USgpm Pressure Drop - bar Flow - L/min Flow - USgpm Pressure Drop - bar Flow - L/min Pressure Drop - PSID Pressure Drop - PSID Flow vs Current Current - ma Note: To determine operating characteristics for the flow rating selected, at a specific differential pressure, first determine maximum flow from upper curve at the differential pressure value. This will be the % flow on the lower curve. Parameters: 4 Hz PWM An Eaton rand -.A

44 EFV--O - Proportional Valve Proportional flow, normally open spool Up to 4 L/min (7.5 USgpm) bar (3 psi) Model Code EFV * * * * *** *****E** Function EFV - Electro proportional flow control valve Size - size 3 Seal Material N - una-n V - Viton 4 Logic - Normally open 5 Flow Rating A PSID PSID 6 Manual Override Option - No core tube special features S - Screw-in 8 Port Size Code Port Size Housing Number Cartridge only Aluminium Single Steel Single 4G /" SPP G 3/4" SPP T SAE T SAE Note: oth the manifold and port plug are required. See section J for housing details. 7 Valve Housing Material lank - Cartridge only A - Aluminum S - Steel 9 Coil Series E - E series coils *These model digits will not be stamped on the valve. For coil part numbers and dimensions see section C. Special Features - None Only required when valve has special features, omitted if. -.A An Eaton rand

45 EFV--O - Proportional Valve Proportional flow, normally open spool Up to 4 L/min (7.5 USgpm) bar (3 psi) Dimensions mm (inch) Cartridge Only Torque cartridge in housing S Nm (-49 ft lbs) A - 8- Nm (8-9 ft lbs) Note: Port is unused and must be plugged. Note: EFV- with DIN-4365 connector shown. 44, (.74) 3,8 (.9) 9, (.75).6 86,3 (3.4) 64, (.5) 68,6 (.7) 3 Installation Drawing (Aluminum) 5.4 (.) (.46).7 (.5) 5.4 (.) 8.7 (.3) 3 8 (4.5) 8.55 (3.5) 5.6 (.3) 44.5 (.75) 76. (3.) 88.9 (3.5) An Eaton rand -3.A

46 PFR4A - Proportional Valve Proportional bi-directional, normally closed poppet 8 L/min at 75% bar (3 psi) Operation Features Sectional View In the de-energized condition the valve is closed. As current is applied to the coil the valve opens proportionally allowing flow from port to port. High flow capacity with reduced space requirements. Standard valve bodies and common cavities. One-piece encapsulated coil with minimal amperage draw. Oil immersed armature solenoid. Various coil terminals and voltages. Coil interchangeability with valves of same series. Manual override, seal variations and other options available. Sealed coil arrangement to protect stem from corrosion. Reversible coil without affecting performance. Description (out) (in) This is a compact ported proportional, pressure compensated, spool type flow regulator. Ideal for speed regulation of actuators in many applications. Performance Data Ratings and Specifications Performance data is typical with fluid at 3 cst (5 SUS) Max inlet pressure bar (3 psi) Rated flow 8 %, 3 85%, 8 L/min@ 75% Hystersis 8% maximum without PWM, 4% maximum with PWM Frequency Hz to 4 Hz - recommended Dead band 5-35% of rated current Response time 3 ms Internal leakage Up to ml/min, bar differential Temperature range -3 to C (- to 48 F) Cavity A67 (see section M) Electrical data See coil data sheet Torque cartridge into cavity 3 Nm ( lbs ft) Mounting position Unrestricted Fluids All general purpose hydraulics fluids such as: MIL-H-566, SAE, SAE, etc Seal Material Standard nitrile with PTFE back up rings Filtration S554/4 Class 6/3 (5 micron or better) Nominal viscosity range 5 to 5 cst Standard housing materials Aluminium alloy Coil Weight.3 kg (.6 lbs) Weight. kg (.44 lbs) Seal kit SK974 (Nitrile) SK974V (Viton ) Viton is a registered trademark of E.I. DuPont Pressure - psi Pressure Drop Curves Flow - L/min Flow - US gpm Pressure - bar Flow - litres/min % rated amps Flow US gpm Flow - US gpm Pressure differential - bar % of rated amps % of rated amps 5 5% of rated amps Pressure - psi Flow - l/min -3.A An Eaton rand

47 PFR4A - Proportional Valve Proportional bi-directional, normally closed poppet 8 L/min at 75% bar (3 psi) Model Code PFR 4A N 6 H 4 3W Function PFR 4A - Cartridge only Seal Material N - Nitrile V - Viton 3 Manual Override 6 - Screw 4 Coil Termination H - DIN4365 F - Flying Lead DM - Deutsch moulded Other terminations available on request. 5 Voltage - VDC 4-4 VDC 6 Port Size Code Port Size Housing Number Aluminium Cartridge only W /4" SP A59 3W 3/8" SP A745 6T 3/8" SAE A9355 See section J for housing details. Dimensions mm (inch) Cartridge Only Installation Drawing 7. (.8) 49. (.9). (.8) 5. A/F. A/F 35.5 (.4) 5. (.97) 9. (3.6) 5. (.97) holes Ø6.8 (.7) thro 6. (.63). (.87) 6. (.4) 6. (.4) 9. (.75).8 (.5) 5.9 (.63) 3.8 (.5) 5.8 (. 4. A/F 7.8 (.9) 6.9 (.66) 3/4-6-UNF-A Ø5.8 (.6) An Eaton rand -3.A

48 EFV--C - Proportional Valve Proportional flow, normally closed spool Up to 4 L/min (3 USgpm) bar (3 psi) Operation Current supplied to the coil controls the valve. At zero current, the valve is fully closed from port to port 3. At 5 to 6 ma (V coil) the valve is fully open. The valve will regulate flow out of port 3 regardless of downstream system pressure. As current is increased to the solenoid the flow out of port 3 will increase. Features Hardened and ground working parts to give long life with good control; Compact design with low pressure drop.ip69k Tough coil compatibility, continuously rated. Sectional View Description 3 Ratings and Specifications 3 This is a three port pressure compensated proportional normally closed flow control screw in cartridge valve. The valve can be used as a priority or a restrictive style valve allowing the valve to control the outlet flow with the option of the excess flow being used for another system. Performance Data Performance data is typical with fluid at,8 cst (5 SUS) and 49 C ( F) Typical application pressure bar (3 psi) Cartridge endurance rating million cycles Cartridge fatigue pressure (infinite life) bar (3 psi) NFPA rated Rated flow A Spool-max regulated flow (by-pass mode): 57 L/min (5 USgpm) max regulated flow ( port mode): 53 L/min (4 USgpm) max input flow (input flow): 4 L/min (3 USgpm) Spool-max regulated flow (by-pass mode): 38 L/min ( USgpm) max regulated flow ( port mode): 3 L/min (8 USgpm) max input flow (input flow): 4 L/min (3 USgpm) Note: Max regulated flow may decrease slightly during compensation. Internal leakage (fully closed) 4 cm 3 /min (5 in 3 3 PSID Nominal supply voltage /4 V Current to fully open valve 6 ma (V coil), 8 ma (4V coil) Current to fully close valve 35 ma (V coil), 75 5 ma (4V coil) Recommended PWM frequency -4 Hz Coil resistance 4.7v /V, 9. /4V Mass Cartridge only,37 kg (.8 lb), cartridge with coil and end nut,73 kg (.6 lb) Temperature range -3 to 9 C (- to 94 F) Maximum oil temperature C (48 F) Maximum internal coil temperature C (39 F) Cavity C--3 Fluids All general purpose hydraulics fluids such as: MIL-H-566, SAE, SAE, DTE 4, etc. Filtration Cleanliness code 8/6/3 Housing material (standard) Aluminum or steel Hysterisis.5 USgpm with 4Hz PWM driver Seal kit 997- (una-n), 997- (Viton ) Viton is a registered trademark of E.I. DuPont -5.A An Eaton rand

49 EFV--C - Proportional Valve Performance Curves Flow is Pressure Drop Flow vs Pressure Drop Excess flow P to P (P3 to Atm) Full current (7 ma on a V Coil) Flow vs Pressure Drop Regulated flow P to P3 (P to Atm) Full current (7 ma on a V Coil) Pressure Drop psi Flow-US gpm 5 3 Pressure Drop - psi A 7.5. Flow-US gpm Flow vs Current A - A spool pressure drop - spool pressure drop Flow (GPM) A Current (ma) y-pass Mode Port Mode Port Mode y-pass Mode A - A spool - spool Regulated Flow vs Pressure Regular to ypass Flow-US gpm E C A 5 G D F 5 Pressure - psi 5 3 A -.3 AMPS -.6 AMPS C -.9 AMPS D -. AMPS E -.5 AMPS F -.8 AMPS G -. AMPS 35 Regulated Flow vs Pressure ypass to Regular Flow-US gpm F D 5 C E G A 5 Pressure - psi 5 3 A -.3 AMPS -.6 AMPS C -.9 AMPS D -. AMPS E -.5 AMPS F -.8 AMPS G -. AMPS 35 Note: Pressure Compensation curves are shown for spool valves. An Eaton rand -5.A

50 EFV--C - Proportional Valve Proportional flow, normally closed spool Up to 4 L/min (3 USgpm) bar (3 psi) Model Code EFV * C * * * *** *****E** Function EFV - Electro proportional flow control valve Size - size 6 Manual Override Option - No core tube special features S - Screw-in 8 Port Size 7 Valve Housing Material - Cartridge only A - Aluminum S - Steel 9 Coil Series E - E series coils *These model digits will not be stamped on the valve. For coil part numbers and dimensions see section C. 3 Seal Material N - una-n V - Viton 4 Logic C - Normally closed 5 Flow Rating A PSID - 8 PSID See specifications Code Port Size Housing Number Cartridge only Aluminium Single Steel Single 4G /" SPP G 3/4" SPP T SAE T SAE Note: oth the manifold and port plug are required. See section J for housing details. Special Features - None Only required when valve has special features, omitted if. -5.A An Eaton rand

51 EFV--C - Proportional Valve Proportional flow, normally closed spool Up to 4 L/min (3 USgpm) bar (3 psi) Dimensions mm (inch) Torque cartridge in housing S Nm (-49 ft lbs) A - 8- Nm (8-9 ft lbs) Note: EFV- with DIN-4365 connector shown. Cartridge Only 44, (.74) 3,8 (.9) 9, (.75).6 86,3 (3.4) 64, (.5) 68,6 (.7) 3 Installation Drawing (Aluminum) 5.4 (.) (.46).7 (.5) 5.4 (.) 8.7 (.3) 3 8 (4.5) 8.55 (3.5) 5.6 (.3) 44.5 (.75) 76. (3.) 88.9 (3.5) An Eaton rand -53.A

52 EFV--O - Proportional Valve Proportional flow, normally open spool Up to 4 L/min (3 USgpm) bar (3 psi) Operation Current supplied to the coil controls the valve. At zero current, the valve is fully open from port to port 3. At 6 ma (V coil) the valve is fully closed. The valve will regulate flow out of port 3 regardless of downstream system pressure. As current is increased to the solenoid the flow out of port 3 will decrease. Features Hardened and ground working parts to give long life with good control; Compact design with low pressure drop.ip69k Tough coil compatibility, continuously rated. 3 Sectional View 3 Performance Data Ratings and Specifications Performance data is typical with fluid at,8 cst (5 SUS) and 49 C ( F) Typical application pressure bar (3 psi) Cartridge endurance rating million cycles Cartridge fatigue pressure (infinite life) bar (3 psi) NFPA rated Rated flow A Spool-max regulated flow (by-pass mode): 53 L/min (4 USgpm) max regulated flow ( port mode): 4 L/min ( USgpm) max input flow (input flow): 4 L/min (3 USgpm) Spool-max regulated flow (by-pass mode): 38 L/min ( USgpm) max regulated flow ( port mode): 3 L/min (8 USgpm) max input flow (input flow): 4 L/min (3 USgpm) Note: Max regulated flow may decrease slightly during compensation. Internal leakage (fully closed) cm 3 /min (5-3 in 3 3 PSID Nominal supply voltage /4 V Current to fully open valve 35 ma (V coil), 8 ma (4V coil) Current to fully close valve 6 ma (V coil), 8 ma (4V coil) Recommended PWM frequency -4 Hz Coil resistance 4.7v /V, 9. /4V Mass Cartridge only,37 kg (.8 lb), cartridge with coil and end nut,73 kg (.6 lb) Temperature range -3 to 9 C (- to 94 F) Maximum oil temperature C (48 F) Maximum internal coil temperature C (39 F) Cavity C--3 Fluids All general purpose hydraulics fluids such as: MIL-H-566, SAE, SAE, DTE 4, etc. Filtration Cleanliness code 8/6/3 Housing material (standard) Aluminum or steel Hysterisis.5 USgpm with 4Hz PWM driver Seal kit 997- (una-n), 997- (Viton ) Viton is a registered trademark of E.I. DuPont Description This is a three port pressure compensated normally open proportional flow control screw in cartridge valve. The valve can be used as a priority or a restrictive style valve allowing the valve to control the outlet flow with the option of the excess flow being used for another system. -6.A An Eaton rand

53 EFV--O - Proportional Valve Performance Curves Pressure Drop Port to Port Pressure Drop Port to Port 3 Pressure Drop (PSI) GPM 5 3 Pressure Drop (PSI) GPM G 7.5 A..5 Flow vs Current - A Spool Flow (GPM) y-pass Mode Port Mode Flow vs Current - Spool 6 4 Flow (GPM) y-pass Mode Port Mode Current (Milli-amps) Current (Milli-amps) Parameters: 4 Hz PWM Regulated Flow vs Pressure Port 3 Pressure > Port Pressure Regulated Flow vs Pressure Port Pressure > Port 3 Pressure GPM 5..5 A. 7.5 C 5. D.5. E F A amps.3 amps C.6 amps D.9 amps E. amps F.5 amps 35 4 PSI GPM 5..5 A. 7.5 C 5. D.5 E. F A amps.3 amps C.6 amps D.9 amps E. amps F.5 amps 35 4 PSI Note: Pressure Compensation curves are shown for spool valves. An Eaton rand -6.A

54 EFV--O - Proportional Valve Proportional flow, normally open spool Up to 4 L/min (3 USgpm) bar (3 psi) Model Code EFV * * * * *** *****E** Function EFV - Electro proportional flow control valve Size - size 6 Manual Override Option - No core tube special features S - Screw-in 8 Port Size 7 Valve Housing Material - Cartridge only A - Aluminum S - Steel 9 Coil Series E - E series coils *These model digits will not be stamped on the valve. For coil part numbers and dimensions see section C. 3 Seal Material N - una-n V - Viton 4 Logic - Normally open 5 Flow Rating A PSID - 8 PSID See specifications Code Port Size Housing Number Cartridge only Aluminium Single Steel Single 4G /" SPP G 3/4" SPP T SAE T SAE Note: oth the manifold and port plug are required. See section J for housing details. Special Features - None Only required when valve has special features, omitted if. -6.A An Eaton rand

55 EFV--O - Proportional Valve Proportional flow, normally open spool Up to 4 L/min (3 USgpm) bar (3 psi) Dimensions mm (inch) Cartridge Only Torque cartridge in housing S Nm (-49 ft lbs) A - 8- Nm (8-9 ft lbs) Note: EFV- with DIN-4365 connector shown. 44, (.74) 3,8 (.9) 9, (.75).6 86,3 (3.4) 64, (.5) 68,6 (.7) 3 Installation Drawing (Aluminum) 5.4 (.) (.46).7 (.5) 5.4 (.) 8.7 (.3) 3 8 (4.5) 8.55 (3.5) 5.6 (.3) 44.5 (.75) 76. (3.) 88.9 (3.5) An Eaton rand -63.A

56 PDRA - Proportional Valve Proportional relief.5 L/min (.3 USgpm) 35 bar (5 psi) Operation Features Sectional View The poppet is held on the seat by a light spring. The force is increased by the application of magnetic force due to the increase in current. This increases the pressure required to lift the poppet of the seat thus controlling the pressure. High flow capacity with reduced space requirements. No dynamic seals. Standard valve bodies and common cavities. One-piece encapsulated coil with minimal amperage draw. Oil immersed armature solenoid. Various coil terminals and voltages. Coil interchangeability with valves of same series. Manual override, seal variations and other options available. Sealed coil arrangement to protect stem from corrosion. Description This is a proportional poppet style pilot relief cartridge. The pressure setting is directly proportional to changes in DC current input. The valve is ideal for the control of larger valves for the control of a pressure within a system. Performance Data Ratings and Specifications Performance data is typical with fluid at,8 cst (5 SUS) and 49 C ( F) Max inlet pressure 35 bar (5 psi) Pressure range = 5-7 bar (7-55 psi), = 4- bar (-3 psi), 35 = -35 bar (3-5 psi) Max press port bar (45 psi) Max flow.5 L/min (.3 US GPM) Hystersis <.5% without PWM Dead band % approx Response time = -93 ms, = ms, 35 = -358 ms Internal leakage <5 ml/min Temperature range -3 to C (- to 48 F) Cavity A879 (see Section M) Electrical data See coil data sheet Torque cartridge into cavity 4 Nm (9.5 lbs ft) Mounting position For best results mount below reservoir oil level. If this is not feasible mount horizontally Fluids All general purpose hydraulics fluids such as: MIL-H-566, SAE, SAE, etc Seal material Standard nitrile with PTFE back up rings Filtration S554/4 Class 8/3 (5 micron or better) Nominal viscosity range 5 to 5 cst Standard housing materials Aluminium Coil Model Code C6-*-*/9 Coil Weight.3 kg (.6 lbs) Weight.5 kg (.55 lbs) Voltage available /4 VDC Seal kit SK9 (Nitrile) SK9V (Viton ) Viton is a registered trademark of E.I. DuPont Pressure - psi Performance Curves Flow - L/min bar 4- bar...3 Flow - US gpm 5-7 bar.4 Pressure - bar Pressure - psi bar 5-7 bar - bar % of rated current Pressure - bar Pressure - psi Flow - L/min bar 4- bar -35 bar 75% 5% 5% 75% 5% 5%...3 Flow - US gpm 5% 5% Pressure - bar -7.A An Eaton rand

57 PDRA - Proportional Valve Proportional relief.5 L/min (.3 USgpm) 35 bar (5 psi) Model Code PDRA N 6 H 4 3W Function PDRA - Normally open Seal Material N - Nitrile V - Viton 3 Pressure Range - 5 to bar - to 4 bar 4 Manual Override 6 - Screw 5 Coil Termination H - DIN4365 F - Flying Lead DM - Deutsch moulded Other terminations available on request. 6 Voltage - VDC 4-4 VDC 7 Port Size Code Port Size Housing Number Aluminium Steel Cartridge only W /4" SP A485 A48 3W 3/8" SP A43 A475 4T /4" SAE A484-6T 3/8" SAE A5676 A4843 Dimensions mm (inch) Cartridge Only Installation Drawing. (.8) 49. (.9) 5. A/F Man override. A/F Man override locknut 35.5 (.4).7 (.5) 8.8 (.3). (3.98) 4. A/F 5. (.97) 6. (.63) 3. (.) 44. (.73) 5. (.97) (.76) (.) holes Ø6.8 (.7) through 5.9 (.63) 3.8 (.5) 9. (.4) 3/4-6 UNF 9.4 (.76) T() Ø.6 (.5) P() An Eaton rand -7.A

58 IRV- - Proportional Valve Proportional inverse relief, poppet L/min (.5 USgpm) bar (3 psi) Operation The IRV- proportional relief is spring biased closed to the highest setting. Increasing current to the coil will proportionally decrease the pressure setting. When the pressure at port (inlet) is enough to overcome the spring force, the poppet lifts and allows flow from port to port (outlet). Features Hardened and ground components for accurate consistent control and a long life. IP69K Tough coil compatibility continuously rated. Sectional View Performance Data Ratings and Specifications Performance data is typical with fluid at,8 cst (5 SUS) and 49 C ( F) Typical application pressure bar (3 psi) Cartridge endurance rating million cycles Cartridge fatigue pressure rating (NFPA/T.6. R-) bar (3 psi) Maximum pressure setting range 35- bar (3 psi) Rated flow L/min, (.5 USgpm) Nominal supply voltage /4 V Temperature range -3 to 9 C (- to 94 F) Maximum oil temperature C (48 F) Maximum internal oil temperature C (39 F) Cavity C-- Fluids All general purpose hydraulic fluids such as: MIL-H-566, SAE, SAE, etc. Filtration Cleanliness code 8/6/3 Housing material (standard) Aluminum Hysterisis psi with dither Weight cartridge only,3 kg (.3 lbs) Seal kit (una-n), (Viton ) Viton is a registered trademark of E.I. DuPont Endurance tested to million cycles at full rated flow and pressure. Description This is a proportionally controlled inverse pilot poppet relief valve. Ideal for use with logic elements to control fan or brush pressure where full speed or force is required under electrical failure. Pressure Drop Pressure (psi) Metering Performance A C 6 4 D 6 E Pressure (bar) Amps Pressure Differential A - 35 psi - 3 psi C - psi D - psi E - 5 psi -8.A An Eaton rand

59 IRV- - Proportional Valve Proportional inverse relief, poppet L/min (.5 USgpm) bar (3 psi) Model Code IRV * ** * ** *** * * * * ** Function IRV - Inverse proportional relief Size - size 3 Seal Material lank - una-n V - Viton 4 Factory Set Pressure User requested in psi increments. Max pressure setting range 5-3 psi Example 5-5 psi 3-3 psi 5 Housing Material lank - Cartridge only A - Aluminum 6 Port Size 9 Connector Type Code Port Size Housing Number lank - No coil G - ISO 44 DIN 4365 Aluminum Single Aluminum Single Q - Spade Terminals Light Duty Fatigue Rated W - Flying Lead Cartridge only N - Deutsch (DC only) Y - Amp JR (DC only) 6T SAE P - Conduit 8T SAE For coil part numbers and dimensions G /4" SPP see section C. 3G 3/8" SPP H SAE H SAE See section J for housing details. 7 Coil Voltage - No coil - VDC - VDC 4-4VDC 8 Type of Power lank - No coil D - DC w/o diode - DC with diode Coil Series lank - No coil J - J Series, W For coil part numbers and dimensions see section C. Coil Special Features lank - No coil - No special feature Valve Special Features lank - No coil Dimensions mm (inch) Cartridge Only Installation Drawing 9, HEX (.75) 7.4 (.85) 5.4 (.) 7,4 (.85) X 7. (.8) 63.5 (.5).8 (.8) 33, (.3) 5,4 HEX (.),875-4 THD. 34,6 (.36) 9.5 (.37) 63.5 (.5) 9. (.75) Ø 5,8 (.6) Ø 38,9 (.53) An Eaton rand -8.A

60 ERV- - Proportional Valve Proportional relief, spool L/min ( - 5 USgpm) 4 bar (35 psi) Operation This valve remains closed between port and until the predetermined pressure setting has been reached at port, overcoming the electrical force and opening the spool to allow flow from port to port. Features Hardened and ground components for accurate consistent control and a long life. Pilot style to give accurate pressure control over varying flows. IP69K Tough coil compatibility continuously rated. Sectional View Performance Data Ratings and Specifications Performance data is typical with fluid at,8 cst (5 SUS) and 49 C ( F) Typical application pressure (all ports) -4 bar (3-35 psi) Cartridge fatigue pressure (infinite life) 4 bar (35 psi) Rated flow 3.8-6, L/min (-5 USgpm) Temperature range -4 to C (-4 to 48 F) Cavity C-- Fluids All general purpose hydraulic fluids such as: MIL-H-566, SAE, SAE etc. Filtration Cleanliness code 8/6/3 Housing material (standard) Aluminum Weight including coil,44 kg (.98 lbs) Seal kit (una-n), (Viton ) Viton is a registered trademark of E.I. DuPont Description This is a proportional internally pilot operated screw in cartridge relief valve. Good control over large flows for the physical size of the cartridge. Ideal for the control of pressure under varying flow conditions. Pressure Drop - psi Pressure Drop Curves Pressure override, energized 3 Performance Curves Cartridges only bar Flow - L/min (,8 cst 49 C) psi Step response Zero outlet pressure Flow - USgpm (5 SUS F) 5 Volts Pressure Drop - bar Pressure override, de-energized Pressure Drop - psi 5 4 Flow - L/min (,8 cst 49 C) Flow - USgpm (5 SUS F) Pressure gain Pressure Drop - bar Pressure Input voltage Pressure - psi Pressure - bar seconds Response time 3 6 9volts Input 5 C (77 F) -9.A An Eaton rand

61 ERV- - Proportional Valve Proportional relief, spool L/min ( - 5 USgpm) 4 bar (35 psi) Model Code ERV (V) ** ** *** * Function ERV - Proportional relief valve Size - size 3 Seal Material lank - una-n V - Viton 4 Maximum Pressure Customer to specify settings in increments of 7 bar ( psi) and coded in hundreds of psi within the 35- bar range (5-3 psi) range. Example: 5-35, (5 psi) 5 Port Size 7 Connector Types Code Port Size Housing Number Aluminum Single lank - No coil G - DIN 4365 Q - Spade Terminals Cartridge only W - Flying Lead 6T SAE * N - Deutsch Y - Amp JR G /4" SPP 8767* For coil part numbers and 3G 3/8" SPP dimensions see section C. 6H SAE H SAE Special Features *Light duty housing. See section J for housing details. - None Only required if valve has special features, omitted if. 6 Voltage Rating - No coil D - VDC 4D - 4VDC - VDC/w diode* 4-4VDC/w diode* *Optional arc suppression diode. Note: This valve uses the standard J series coils, see section C for coil part numbers and specifications. Dimensions mm (inch) Torque cartridge in aluminum housing Nm (35-4 ft lbs) Cartridge Only Installation Drawing Valve is shown with W coil. 9,6 (.6) 73. (.87) 5.4 (.) Ø 38,9 (.53) 9, (.75) Hex X 7. (.8) 63.5 (.5).8 (.8) 73, (.87) 5,4 (.) Hex 9.5 (.37) 63.5 (.5) 9. (.75) 33,3 (.3).875"-4 Thd. Ø 5,8 (.6) WARNING Maintain 5-8 Nm (4-6 ft lbs) maximum torque on valve tube nut. Over tightening may cause valve failure. An Eaton rand -9.A

62 ERV-6 - Proportional Valve Proportional relief, spool Up to 3 L/min (35 USgpm) bar (3 psi) Sectional View Operation This valve remains closed between port and until the predetermined pressure setting has been reached Performance Data Ratings and Specifications at port, overcoming the electrical force and opening the spool to allow flow from port to port. Features Hardened and ground components for accurate consistent control and a long life. Pilot style to give accurate pressure control over varying flows. IP69K Tough coil compatibility continuously rated. Performance data is typical with fluid at,8 cst (5 SUS) and 49 C ( F) Typical application pressure (all ports) 3,5- bar (5-3 psi) Cartridge fatigue pressure (infinite life) bar (3 psi) Rated flow 7,6-3, L/min (-35 USgpm) Temperature range -4 to C (-4 to 48 F) Cavity C-6- Fluids All general purpose hydraulic fluids such as: MIL-H-566, SAE, SAE etc. Filtration Cleanliness code 8/6/3 Housing material (standard) Aluminum Weight including coil,44 kg (.98 lbs) Seal kit 5658 (una-n), (Viton ) Viton is a registered trademark of E.I. DuPont Pressure Drop Curves Pressure override, energized Pressure override, de-energized 3 Flow - L/min (,8 cst 49 C) Flow - L/min (,8 cst 49 C) Description This is a proportional internally pilot operated screw in cartridge relief valve. Good control over large flows for the physical size of the cartridge. Ideal for the control of pressure under varying flow conditions. Pressure - psi Flow - USgpm (5 SUS F) Performance Curves Cartridges only 4 7 Zero outlet pressure Pressure - bar Pressure - psi Flow - USgpm (5 SUS F) Pressure - bar bar psi Step response Volts 36 Pressure gain 8 Pressure Input voltage Pressure - psi Pressure - bar seconds Response time volts Input 5 C (77 F) -3.A An Eaton rand

63 ERV-6 - Proportional Valve Proportional relief, spool Up to 3 L/min (35 USgpm) bar (3 psi) Model Code ERV 6 (V) ** *** *** * Function ERV - Proportional relief valve Size 6-6 size 3 Seal Material lank - una-n V - Viton 4 Maximum Pressure Customer to specify settings in increments of 7 bar ( psi) and coded in hundreds of psi within the 35- bar range (5-3 psi) range. Example: 5-35, (5 psi) 5 Port Size 7 Connector Types Code Port Size Housing Number Aluminum Single lank - No coil G - DIN 4365 Q - Spade Terminals Cartridge only W - Flying Lead T SAE 56649* N - Deutsch Y - Amp JR 4G /" SPP 87676* For coil part numbers and 6G 3/4" SPP dimensions see section C. H SAE H SAE Special Features *Light duty housing. See section J for housing details. - None Only required if valve has special features, omitted if. 6 Voltage Rating - No coil D - VDC 4D - 4VDC - VDC/w diode* 4-4VDC/w diode* *Optional arc suppression diode. Note: This valve uses the standard J series coils, see section C for coil part numbers and specifications. Dimensions mm (inch) Cartridge Only Torque cartridge in aluminum housing 8- Nm (8-9 ft lbs) Installation Drawing 9,6 (.6) 77.9 (3.7) 3.8 (.5) Ø 38,9 (.53) 9, (.75) Hex Torque to 5-8 Nm 88.9 (3.5) X 8.74 (.344) 8.4 (.) 79, (3.).3 (.4) 68.8 (.688) 88.9 (3.5) 38, (.5) Hex 44,4 (.75).3"- Thd. Ø 8,55 (.4) WARNING Maintain 5-8 Nm (4-6 ft lbs) maximum torque on valve tube nut. Over tightening may cause valve failure. An Eaton rand -3.A

64 PPDA - Proportional Valve Proportional Reducing/Relief, Spool L/min (5.4 USgpm) bar (3 psi) Operation Features 3 Sectional View In the de-energized position, pressure inlet port is open to reduced pressure port, return port 3 is closed. As electrical current is increased, the setting of the valve increases allowing pressure at port to increase. If the pressure at port exceeds the setting of the valve, the spool will shift further and relieve to port 3. High flow capacity with reduced space requirements. No dynamic seals. Standard valve bodies and common cavities. One-piece encapsulated coil with minimal amperage draw. Oil immersed armature solenoid. Various coil terminals and voltages. Coil interchangeability with valves of same series. Manual override, seal variations and other options available. Sealed coil arrangement to protect stem from corrosion. 3 (Tank) (Pres) Description (Reg) This is a low pressure proportional direct acting pressure reducing valve with a reverse relief screw in cartridge valve. It is ideal for the control of compensators on a pump or brake and clutch systems on a transmission circuit. Performance Data Ratings and Specifications Performance data is typical with fluid at 3 cst (5 SUS) Max inlet pressure bar (3 psi) Max regulated pressure 9 watt coil 4 bar, 9 watt coil 8 bar Max flow 8.6 L/min (5 USgpm) 9 watt coil L/min (5.4 USgpm) 9 watt coil Hystersis 6% max without PWM Frequency Hz Dead band 9% approx Response time = -93 ms, = ms, 35 = -358 ms Internal leakage Up to 5 ml/min at bar differential Temperature range -3 to C (- to 48 F) Cavity A353 (see Section M) Torque cartridge into cavity 3 Nm ( lbs ft) Mounting position Unrestricted Fluids All general purpose hydraulics fluids such as: MIL-H-566, SAE, SAE, etc Seal material Standard nitrile with PTFE back up rings Filtration S554/4 Class 8/3 (5 micron or better) Nominal viscosity range 5 to 5 cst Standard housing materials Aluminium Coil weight.3 kg (.6 lbs) Weight cartridge only.5 kg (.55 lbs) Seal kit SK9 (Nitrile) SK9V (Viton ) Coil part number C6*-*/9 (PPDA) C6-*-*/9 (PPDH) Voltage available, 4 VDC Viton is a registered trademark of E.I. DuPont Pressure Drop Flow - L/min Pressure - psi Flow - US gpm 4 3 Pressure - bar Performance Curve Pressure - psi 88 PPD AH 6 PPD A % of rated current Pressure - bar -3.A An Eaton rand

65 PPDA - Proportional Valve Proportional Reducing/Relief, Spool L/min (5.4 USgpm) bar (3 psi) Model Code PPDA N H 4 3W Function PPDA - Standard PPDH - Heavy duty Seal Material N - Nitrile V - Viton 3 Coil Termination H - DIN4365 F - Flying Lead DM - Deutsch moulded Other terminations available on request. 4 Voltage - VDC 4-4 VDC 5 Port Size Code Port Size Housing Number Aluminium Single Cartridge only W /4" SP A774 3W 3/8" SP A6684 6T 3/8" SAE 656 See section J for housing details. Dimensions mm (inch) Cartridge Only Installation Drawing 49. (.9) 57. (.5). (.8) 7. (.8) 35.5 (.4) holes Ø7. (.8) thro 8.3 (.). (.44) 4.7 (.58) 9. (3.6) 4. A/F 5. (.97) 8.6 (.3) 4.8 (.9) (.87) 38. (.5).7 (.5) 5.4 (.) 39.8 (.57) 3/4-6-UNF-A 3 (Tank) (Pressure) 6.9 (.67) Ø4. (.56) Ø5.8 (.6) (Regulated) An Eaton rand -3.A

66 EPRV-8 - Proportional Valve Proportional reducing/relief, spool 7.6 L/min ( USgpm) 35 bar (5 psi) 3 Operation In the de-energized position, pressure inlet port is closed and reduced pressure port is open to return port 3. As electrical current is increased, port opens to port and port 3 closes, proportionally increasing pressure at port. If the pressure at port exceeds the setting of the valve, the spool will shift further and relieve to port 3. Features Hardened and ground components for accurate consistent control and a long life. IP69K Tough coil compatibility continuously rated. Sectional View 3 (T) Performance Data Ratings and Specifications Performance data is typical with fluid at,8 cst (5 SUS) and 49 C ( F) Maximum inlet pressure 35 bar (5 psi) Cartridge fatigue pressure (infinite life) 35 bar (5 psi) Reduced pressure range - bar (-3 psi) Maximum operating flow 7,6 L/min ( USgpm) Temperature range -4 to C (-4 to 48 F) Cavity C-8-3 Fluids All general purpose hydraulic fluids such as: MIL-H-566, SAE, SAE etc. Filtration Cleanliness code 8/6/3 Recommended PWM frequency 5 Hz 5 Hz PWM 5% Housing material (standard) Aluminum Weight including coil,9 kg (.64 lbs) Seal kit (una-n), (Viton ) Viton is a registered trademark of E.I. DuPont Description (RP) (P) This is a low pressure proportional direct acting pressure reducing valve with a reverse relief screw in cartridge valve. It is ideal for the control of compensators on a pump or brake and clutch systems on a transmission circuit. Pressure Drop Curves Pressure drop - psi Flow - L/min (,8 cst 49 C) A Flow - USgpm (5 SUS F) Pressure drop - bar Pressure - psi Flow - L/min (,8 cst 49 C) Relieving mode Reducing mode 4 4 Flow - USgpm (5 SUS F) Pressure - bar Reduced pressure bar psi 6 4 Step response Time - sec A - Port to port 3 - Port to port Performance Curves ( VDC)..8.4 Amperage Reduced pressure - psi 4 3 Regulated pressure vs amperage ( VDC) 8 Amperage decreasing Amperage increasing Reduced pressure - bar (4 VDC) -3.A An Eaton rand

67 EPRV-8 - Proportional Valve Proportional reducing/relief, spool 7.6 L/min ( USgpm) 35 bar (5 psi) Model Code EPRV 8 (V) (A) ** *** * * Function EPRV - Proportional reducing/ relieving valve Size 8-8 size 3 Seal Material lank - una-n V - Viton 4 Valve Housing Material Omit for cartridge only A - Aluminum 5 Port Size 7 Connector Types Code Port Size Housing Number Aluminum Single lank - No coil G - DIN 4365 Q - Spade Terminals Cartridge only W - Flying Lead 4T SAE N - Deutsch Y - Amp JR 6T SAE For coil part numbers and G /4" SPP dimensions see section C. 3G 3/8" SPP -674 See section J for housing details. 8 Coil S - S series coils 6 Voltage Rating - No coil D - VDC *Optional arc suppression diode. Note: This valve uses the standard 9 Special Features - None 4D - 4VDC S series coils, see section C for coil Only required if valve has special - VDC/w diode* part numbers and specifications. features, omitted if. 4-4VDC/w diode* Dimensions mm (inch) Torque cartridge in aluminum or steel housing 34-4 Nm (5-3 ft lbs) Cartridge Only Valve is shown with N coil. 6, (.3 ) Installation Drawing 9. (.75) 5.3 (.) 9. (.75) 3,8 (.5 ) 5.5 (.6) 67.3 (.65) 3.4 (.3) (.34) 63.5 (.5) X7.4 (.8) 9.8 (.7) WARNING Maintain 5-8 Nm (4-6 ft lbs) maximum torque on valve tube nut. Over tightening may cause valve failure. An Eaton rand -3.A

68 EPRV-6 - Proportional Valve Proportional reducing/relief, spool 38 L/min ( USgpm) 35 bar (5 psi) 3 Operation This valve remains open from port to port (port 3 must be vented). Once the predetermined pressure is reached at port, the spool shifts to restrict the inlet flow at port, which regulates the pressure at port. If the pressure at port exceeds the setting of the valve, the spool will shift farther and relieve to port 3. Features Hardened and ground components for accurate consistent control and a long life. IP69K Tough coil compatibility continuously rated. Sectional View Performance Data Ratings and Specifications Performance data is typical with fluid at,8 cst (5 SUS) and 49 C ( F) Typical application pressure (all ports) 3,5-35 bar (-5 psi) Cartridge fatigue pressure (infinite life) 35 bar (5 psi) Rated flow -38, L/min (- USgpm) Temperature range -4 to C (-4 to 48 F) Cavity C-6-3 Fluids All general purpose hydraulic fluids such as: MIL-H-566, SAE, SAE etc. Filtration Cleanliness code 8/6/3 Housing material (standard) Aluminum Weight including coil,9 kg (. lbs) Seal kit 5658 (una-n), (Viton ) Viton is a registered trademark of E.I. DuPont 3 Pressure Drop Curves Pressure override, energized Pressure override, de-energized Flow - L/min (8, cst 49 C) Flow - L/min (8, cst 49 C) Pressure - psi Pressure - bar Pressure - psi 5 Pressure - bar 5 5 Flow - USgpm (35 SUS F) 5 5 Flow - USgpm (35 SUS F) Description This is a low pressure proportional pilot operated pressure reducing valve with a reverse relief screw in cartridge valve. It is ideal for the control of compensators on a pump or brake and clutch systems on a transmission circuit. Performance Curves Cartridges only Reduced pressure bar psi 6 4 Step response,,,3,4 Response time Zero outlet pressure volts Input voltage seconds Pressure - psi Pressure gain volts Input 5 C (77 F) Pressure - bar -33.A An Eaton rand

69 EPRV-6 - Proportional Valve Proportional reducing/relief, spool 38 L/min ( USgpm) 35 bar (5 psi) Model Code EPRV 6 (V) ** *** *** * Function EPRV - Proportional reducing/ relieving valve Size 6-6 size 3 Seal Material lank - una-n V - Viton 4 Maximum Pressure Customer to specify settings in increments of 7 bar ( psi) and coded in hundreds of psi within the 4-35 bar range (-5 psi) range. Example: 5-35, (5 psi) 5 Port Size 7 Connector Types Code Port Size Housing Number Aluminum Single lank - No coil G - DIN 4365 Q - Spade Terminals Cartridge only W - Flying Lead 6 3/4" SPP * N - Deutsch Y - Amp JR T SAE 5666* For coil part numbers and 6G 3/4" SPP 8767 dimensions see section C. H SAE 8767 H SAE Special Features *Light duty housing. See section J for housing details. - None Only required if valve has special features, omitted if. 6 Voltage Rating - No coil D - VDC 4D - 4VDC 36D - 36VDC - VDC/w diode* 4-4VDC/w diode* *Optional arc suppression diode. Dimensions mm (inch) Cartridge Only Valve is shown with W coil. Torque cartridge in aluminum housing 8- Nm (8-9 ft lbs) Installation Drawing 3.8 (.5) 77.9 (3.7) 3.8 (.5) 57 (.4) 88.9 (3.5) 4.3 (4.5) (.).3 (.4) (3.688) 4.3 (4.5) X8.74 (.344) WARNING Maintain 5-8 Nm (4-6 ft lbs) maximum torque on valve tube nut. Over tightening may cause valve failure. An Eaton rand -33.A

70 - Additional products, product lines, and services offered by Eaton - For hydropower, it s... Durability. Complete plant control systems for gate operation, turbine governors and balance of plant... including total hydraulic control systems, entire power distribution and control systems, coolant, lubrication and filtration systems. All with the most respected brand name products in the industry, manufactured and warranted by Eaton under a single purchase order. For wind energy, it s... Reliability. Eaton s integrated systems help harvest the inexhaustible green power of wind. In constant use under the harshest conditions, wind turbines demand extreme reliability and durability from every component. Eaton is a world leading manufacturer of those critical hydraulic, electrical and filtration products. For everyone, it s... Sustainability. 8 Eaton Corporation 465 Lone Oak Road Eden Prairie, MN Eaton seeks out and tests the latest environmentally acceptable and biodegradable hydraulic fluids...from all over the world. y leading the way for our customers and their industries, we are working to sustain and safeguard the environment, everywhere our products are at work. -33.A

Hydraulic Screw-in Cartridge Valves (SiCV) Proportional valves Proportional solenoid valves for pressure and flow control

Hydraulic Screw-in Cartridge Valves (SiCV) Proportional valves Proportional solenoid valves for pressure and flow control Hydraulic Screw-in Cartridge Valves (SiCV) Proportional valves Proportional solenoid valves for pressure and flow control Proportional valves PROPORTIONAL VALVES... - PFRH... -8 EPV...- EPV6...- EPV6A...-7

More information

Proportional Valves. Proportional solenoid valves for pressure and flow control

Proportional Valves. Proportional solenoid valves for pressure and flow control Proportional Valves Proportional solenoid valves for pressure and flow control EATON Vickers Screw-In Cartridge Valves V-VLOV-MC-E4 September, 7 - Electro- Proportional Valves Section Contents Typical

More information

Solenoid Valves. Poppet and Spool type solenoid actuated valves for applications up to 350 bar (5000 psi) and 227 L/min (60 USgpm) A-1.

Solenoid Valves. Poppet and Spool type solenoid actuated valves for applications up to 350 bar (5000 psi) and 227 L/min (60 USgpm) A-1. Solenoid Valves Poppet and Spool type solenoid actuated valves for applications up to 5 bar (5 psi) and 7 L/min (6 USgpm) n Eaton Brand ETON Screw-In Cartridge Valves E-VLSC-MC-E November 9 -. Solenoid

More information

Solenoid valves. Poppet and Spool type solenoid actuated valves for applications up to 350 bar (5000 psi) and 227 L/min (60 USgpm)

Solenoid valves. Poppet and Spool type solenoid actuated valves for applications up to 350 bar (5000 psi) and 227 L/min (60 USgpm) Hydraulic Screw-in Cartridge Valves (SiCV) Solenoid valves Poppet and Spool type solenoid actuated valves for applications up to 5 bar (5 psi) and 7 L/min (6 USgpm) Solenoid valves SOLENOID VLVES...- SV5-8-C/CM

More information

Cartridge Valves. Proportional Valves Screw-in Cartridge Valves. Vickers. Maximum Pressure 280 bar (4000 psi) - Maximum Flow 160 l/min (42 USgpm)

Cartridge Valves. Proportional Valves Screw-in Cartridge Valves. Vickers. Maximum Pressure 280 bar (4000 psi) - Maximum Flow 160 l/min (42 USgpm) Vickers Cartridge Valves Proportional Valves Screw-in Cartridge Valves Maximum Pressure 8 bar (4 psi) - Maximum Flow 6 l/min (4 USgpm) Revised 7/ 76 Contents MODEL DESCRIPTION TYPICL PPLICTION PRESSURE

More information

Vickers. Proportional Valves. EPV10 Series. Proportional Flow Controls. Released 6/95

Vickers. Proportional Valves. EPV10 Series. Proportional Flow Controls. Released 6/95 Vickers Proportional Valves EPV1 Series Proportional Flow Controls Released 6/95 715 Table of Contents Features and Benefits..............................................................................

More information

Vickers. Proportional Valves. EPV16 Series Valvistor Proportional Flow Controls

Vickers. Proportional Valves. EPV16 Series Valvistor Proportional Flow Controls Vickers Proportional Valves EPV6 Series Valvistor Proportional Flow Controls Vickers, Incorporated, 998 All rights reserved Features and Benefits The EPV (Electro Proportional Valve) series of poppet valves

More information

Check valves Direct and pilot operated check valve functions for applications up to 350 bar (5000 psi) and 227 L/min (60 USgpm)

Check valves Direct and pilot operated check valve functions for applications up to 350 bar (5000 psi) and 227 L/min (60 USgpm) Hydraulic Screw-in Cartridge Valves (SiCV) Check valves Direct and pilot operated check valve functions for applications up to 5 bar (5 psi) and 7 L/min (6 USgpm) Check valves CHECK VALVES... -4 FPR -

More information

SV9A-10-E - Solenoid Valve 4-way, 3-position spool type solenoid valve Up to 36 L/min (9.5 USgpm) 210 bar (3000 psi)

SV9A-10-E - Solenoid Valve 4-way, 3-position spool type solenoid valve Up to 36 L/min (9.5 USgpm) 210 bar (3000 psi) SV9--E - Solenoid Valve -way, -position spool type solenoid valve Up to 6 L/min (9.5 USgpm) bar ( psi) () () (P) (T) In the de-energized position all ports are closed. When solenoid '' is energized flow

More information

Logic elements. Differential pressure sensing elements for applications up to 350 bar (5000 psi) and 400 L/min (100 USgpm)

Logic elements. Differential pressure sensing elements for applications up to 350 bar (5000 psi) and 400 L/min (100 USgpm) Hydraulic Screw-in Cartridge Valves (SiCV) Logic elements Differential pressure sensing elements for applications up to 50 bar (5000 psi) and 400 L/min (00 USgpm) Logic elements LOGC ELEMENTS... -4 APPLCATON

More information

Catalog HY /US SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. LPM/GPM BAR/PSI

Catalog HY /US SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. LPM/GPM BAR/PSI Catalog HY15-352/US Contents SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. LPM/GPM BAR/PSI PRESSURE RELIEVING AP1B2YP... 2G... Increase /Increase Current...5.3/1.4... 35/5... 7-8 AP2B2YP... C8-2...

More information

Catalog HY /US SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. LPM/GPM BAR/PSI

Catalog HY /US SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. LPM/GPM BAR/PSI Catalog HY15-351/US Contents SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. LPM/GPM BAR/PSI PRESSURE RELIEVING AP1B2YP... 2G... Increase /Increase Current...5.3/1.4... 35/5... 7-8 AP2A2... C8-2... Increase

More information

Proportional Flow-Control Cartridges, Size 5

Proportional Flow-Control Cartridges, Size 5 Proportional Flow-Control Cartridges, Size Q max = l/min, p max = bar, Q N = l/min at p bar Leak free, load compensated, two stage Description Series MVRPLSA two-stage proportional flow-control cartridges

More information

Proportional Valves MODEL DESCRIPTION FLOW CAVITY 4/3 PROPORTIONAL DIRECTIONAL VALVE 8 GPM C1040 PDFC-4M PDFC-4L

Proportional Valves MODEL DESCRIPTION FLOW CAVITY 4/3 PROPORTIONAL DIRECTIONAL VALVE 8 GPM C1040 PDFC-4M PDFC-4L Proportional Valves MODEL DESCRIPTION FLOW CAVITY 4 b a PDFC-4M 4/3 PROPORTIONAL DIRECTIONAL VALVE 8 GPM C040 4 3 b a PDFC-4L 3 3 EPRR-0 PROPORTIONAL PRESS. REDUCING/RELIEVING GPM C030 EPRT-08 PROPORTIONAL

More information

Directional Control Valves

Directional Control Valves Overview HYDAC offers several functions of the Directional Control Cartridges. HYDAC Manually operated position, - way normally closed, spring return, directional valve features poppet design. It offers

More information

DRV2-080 Adjustable, Direct-Acting Relief Valve

DRV2-080 Adjustable, Direct-Acting Relief Valve SOLENOID DRV2-080 Adjustable, Direct-Acting Relief Valve SERIES 8 CHECK MOTION FLOW USASI / ISO ➁ ➀ DESCRIPTION An adjustable, direct-acting poppet cartridge valve designed to limit pressure in hydraulic

More information

Mobile Directional Valve. Product Catalog MDG for Mobile Equipment Flows to 60 I/min (15.8 USgpm)

Mobile Directional Valve. Product Catalog MDG for Mobile Equipment Flows to 60 I/min (15.8 USgpm) Mobile Directional Valve Product Catalog MDG for Mobile Equipment Flows to 60 I/min (15.8 USgpm) Table of Contents General Information...3 Model code Valve Section...4 Valve Assembly...5 Spool Data...6

More information

Directional Control Valve Series D3W Soft Shift

Directional Control Valve Series D3W Soft Shift Characteristics The D3W is a 3-chamber, electrically controlled 4/3 or 4/ way directional control valve. It is activated directly by solenoids with screwed in wet pin armature. The soft shifting of this

More information

DMH085** Series will be available January 1, Catalog HY /US SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO.

DMH085** Series will be available January 1, Catalog HY /US SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. Catalog HY-/US Contents SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. /GPM BAR/PSI DL8... C8-... Position, Way, N.C. Poppet,... Pull to Open.../8... /... DL... C-... Position, Way, N.C. Poppet,... Pull

More information

Pressure Control Valves

Pressure Control Valves Control Valves DR8- Reducing/Relieving, Direct Acting, Spool Type 4 gpm (5 l/min) 6 psi (4 bar) Description A screw-in cartridge, direct acting, spool type, pressure reducing/relieving valve with internal

More information

Vickers Pressure Relief Solenoid Operated, Two-Stage Directional Control Valve DG5S4-02 Flows to 115 l/min (30 USgpm) Pressure to 210 bar (3000 psi)

Vickers Pressure Relief Solenoid Operated, Two-Stage Directional Control Valve DG5S4-02 Flows to 115 l/min (30 USgpm) Pressure to 210 bar (3000 psi) Vickers Pressure Relief Solenoid Operated, Two-Stage Directional Control Valve DG5S4-02 Flows to 115 l/min (30 USgpm) Pressure to 210 bar (3000 psi) Revised 2/93 GB C 2037 Table of Contents Model Code...................................................................................................

More information

Cartridge Valves Technical Information Directional Valves DCV 03

Cartridge Valves Technical Information Directional Valves DCV 03 OVERVIEW DCV 03 directional control valves consist of: housing (1), control spool (5), with two centering springs (4), and cylindrical operating solenoids (2, 3). The three-position directional valves

More information

Proportional Directional Control Cartridge Valves: PSV10-34 & PSV12-34

Proportional Directional Control Cartridge Valves: PSV10-34 & PSV12-34 Control Cartridge Valves: PSV10-34 & PSV12-34 SCHEMATIC PRESSURE* FLOW CAVITY COIL Page 2 PSV10-34-02 250 BAR 3600 PSI 22 LPM 6 GPM SDC10-4 M16-26W R16-20W Page 4 PSV12-34-02 260 BAR 3770 PSI 50 LPM 13

More information

Directional Control Valve Series D1VW

Directional Control Valve Series D1VW Characteristics The NG6 directional control valve series D1VW provides high functional limits up to 8 l/min in combination with a very low, energy-saving pressure drop. A wide variety of spool options

More information

unrestricted; preferably with coil at bottom (auto. air bleed) 12 or 24 Volt DC from an electronic controller Deutsch plug - IP67

unrestricted; preferably with coil at bottom (auto. air bleed) 12 or 24 Volt DC from an electronic controller Deutsch plug - IP67 3 Technical data General characteristics Design Flow direction Seals De-energized position Mounting attitude Description, value, unit line mounting P A controlled P R surplus flow discharge (models shown

More information

Mobile Valves Proportional - Load Sensing

Mobile Valves Proportional - Load Sensing Mobile Valves Proportional - Load Sensing Model CML60 325 bar 60 L/min Up to 8 sections Eaton F(x) Compliant Table of Contents General Information... 3 Model Code Valve Section... 4 Valve Assembly... 5

More information

Chapter 2: Directional Control Valves

Chapter 2: Directional Control Valves Contents Chapter : Directional Control Valves Series Description Direct operated Pilot operated Page DIN / ISO 06 10 16 5 3 10 16 5 3 Seat valves, electrically operated D1SE - Spool valves, electrically

More information

Flow Control Valve. 1 Description. 2 Symbols. Series SRCA General. 1.2 Application examples way flow control way flow control

Flow Control Valve. 1 Description. 2 Symbols. Series SRCA General. 1.2 Application examples way flow control way flow control Flow Control Valve Series SRC.. plug-in coil for easy coil change flow rates are unaffected by changes in temperature or load compact design reduced p ZnNi coating (>70h DIN EN ISO 97 NSS) Description.

More information

Directional Control Valve

Directional Control Valve Characteristics The NG6 directional control valve series D1VW provides high functional limits up to 8 l/min in combination with a very low, energy-saving pressure drop. wide variety of spool options allows

More information

Flow Control Valve. 1 Description. 2 Symbols. Series SRCA General. 1.2 Application examples way flow control way flow control

Flow Control Valve. 1 Description. 2 Symbols. Series SRCA General. 1.2 Application examples way flow control way flow control Flow Control Valve Series SRC.. plug-in coil for easy coil change flow rates are unaffected by changes in temperature or load. compact reduced p ZnNi coating (>70h DIN EN ISO 97 NSS) Description. General

More information

CVH103P. Check Valve Series CVH103P. Technical Information. General Description

CVH103P. Check Valve Series CVH103P. Technical Information. General Description Catalog HY-351/US Information Cartridge Style Valve. For additional information see Tips on pages 1-4. Valve Series H13P Spherical poppet for low leakage D -Ring eliminates back-up rings Dual sense paths

More information

40 l/min (11 GPM) p max

40 l/min (11 GPM) p max Proportional Directional Control Valve, with Analog Control Electronics PRM2-06 Functional Description Size 06 (D03) Q max 40 l/min (11 GPM) p max 350 bar (5100 PSI) Technical Features Direct acting, proportional

More information

P.C. Priority Flow Control Valve Series J02D3. General Description

P.C. Priority Flow Control Valve Series J02D3. General Description CV Catalog HY15-352/US General Description Needle Type, Compensated Regulator Valve. For additional information see Tips on pages 1-4. P.C. Priority Control Valve Series J2D3 Features Good adjustment from

More information

ELECTRIC CARTRIDGES ELECTRO-PROPORTIONAL VALVES

ELECTRIC CARTRIDGES ELECTRO-PROPORTIONAL VALVES ELECTRIC CARTRIDGES ELECTRO-PROPORTIONAL VALVES 6. 9 ELECTRO-PROPORTIONAL VALVES ELECTRIC CARTRIDGES ELECTRO-PROPORTIONAL VALVES In the follow of this chapter, NEM presents the electro-proportional flow

More information

Large Electronically Adjustable Proportional Pressure Compensated Flow Control Engineering & Manufacturing Solutions

Large Electronically Adjustable Proportional Pressure Compensated Flow Control Engineering & Manufacturing Solutions Engineering & Manufacturing Solutions LEFC Specifications: See flow chart for capacity. Max. 3000 psi cartridge input pressure. Nominally Rated for 3000 psi (207 bar). Tank Port - #4 SAE (10 psi (0.69

More information

CLS100 Proportional Load Sensing Mobile Valve

CLS100 Proportional Load Sensing Mobile Valve Mobile Valves Proportional - Load Sensing Model CLS100 350 bar 100 L/min Up to 10 sections Eaton Pro-FX TM Compliant CLS100 Proportional Load Sensing Mobile Valve Overhaul manual / Trouble shooting guide

More information

VSNG10 - SOLENOID OPERATED DIRECTIONAL VALVES

VSNG10 - SOLENOID OPERATED DIRECTIONAL VALVES CONTINENTAL HYDRAULICS VSNG10 SOLENOID OPERATED DIRECTIONAL VALVES 5505 WEST 123RD STREET SAVAGE, MN 55378-1299 / PH: 952.895.6400 / WWW.CONTINENTALHYDRAULICS.COM VSNG10 SOLENOID OPERATED DIRECTIONAL VALVES

More information

20 l/min (5 GPM) p max. Technical Features

20 l/min (5 GPM) p max. Technical Features Proportional Directional Control Valve, with Analogue Control Electronics PRM2-0 Functional Description Size 0 (D02) Q max 20 l/min (5 GPM) p max 320 bar (600 PSI) Technical Features Direct acting, proportional

More information

Directional Control Valve Series 4D01 (DENISON)

Directional Control Valve Series 4D01 (DENISON) Characteristics The Denison series 4D01 is a solenoid operated directional control valve size NG06 in -chamber design. It is direct operated by wet pin solenoids. The 4D01 is available with a Soft Shift

More information

Pilot-Operated Proportional DC Valve Series D*1FH

Pilot-Operated Proportional DC Valve Series D*1FH Characteristics The pilot-operated proportional DC valves series of the D*1FH series are high-performance valves with electronic spool position feedback. These valves are available in sizes NG10 to NG2

More information

Directional Control Valve Series D3W (Parker), 4D02 (Denison)

Directional Control Valve Series D3W (Parker), 4D02 (Denison) Characteristics Series D3W (Parker), 4D0 (Denison) The direct operated directional control valve size NG10 is available with both Parker (series D3W) and Denison (series 4D0) model codes. Both series are

More information

GPM PSI LPM BAR MODEL CAVITY PAGE IF-S3A special IF-S3D special IG-S4A special 198

GPM PSI LPM BAR MODEL CAVITY PAGE IF-S3A special IF-S3D special IG-S4A special 198 Transmission & Brake Spool Valves Screw-in style GPM PSI LPM BAR MODEL CAVITY PAGE 2 1000 8 70 TC-S3A 5/8-18 186 6 1000 23 70 TF-S3A 7/8-14 188 6 1000 23 70 TF-S3D 7/8-14 190 5 1000 20 70 TG-S4A 7/8-14

More information

Proportional Pressure Reducing Valve, Size 16 Series DRPSB 5B...

Proportional Pressure Reducing Valve, Size 16 Series DRPSB 5B... Proportional Pressure Reducing Valve, Size 16 Series DRPSB B... l/min, bar External pilot drain to port 3 Surface protection: Cartridge is chromited, Cr VI free Very stable operation Coil can be changed

More information

D05 Directional Control Valves

D05 Directional Control Valves Engineering D05 Directional Control Valves WFDG4S*4-01, 60 Design Wet Armature Solenoid Operated Max Pressure up to 248 Bar (3600 psi) Same Day Shipments www.fluidynefp.com Table of Contents Basic Characteristicts...2

More information

Pressure Control Valves

Pressure Control Valves Catalog HY15-351/US Contents RELIEF VALVES SEQUEN VALVES Control SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. /GPM BAR/ DIRECT ACTING RDH42... C4-2... Direct Acting Relief, Poppet Type... 3.8/1...

More information

Pilot Operated Directional Control Valves Series D31DW, D41VW - D111VW

Pilot Operated Directional Control Valves Series D31DW, D41VW - D111VW Characteristics The D31, D41, D81, D91 and D111 are electrically controlled 4/3 or 4/ way directional control valves. The valves are pilot operated by an NG6 valve. Pressure and flow of the pilot oil have

More information

SM4-30 Servovalves Flows to 113 l/min (30 USgpm) Pressures to 140 bar (2000 psi)

SM4-30 Servovalves Flows to 113 l/min (30 USgpm) Pressures to 140 bar (2000 psi) Vickers Servo Valves SM4-30 Servovalves Flows to 113 l/min (30 USgpm) Pressures to 140 bar (2000 psi) Released 1/94 653 Introduction Vickers SM4-30 servovalves can provide system closed loop control with

More information

Pilot-Operated Directional Control Valves Series D3 - D11

Pilot-Operated Directional Control Valves Series D3 - D11 Catalogue HY11-500/UK Characteristics The D31, D41, D81, D91 and D111 are electrical controlled 4/3 or 4/ way directional control valves. The valves are pilot-operated by an NG6 valve. Pressure and flow

More information

VER03MP CONTINENTAL HYDRAULICS PROPORTIONAL PRESSURE RELIEF VALVES PILOT OPERATED VER03MP - PROPORTIONAL PRESSURE RELIEF VAVLES PILOT OPERATED

VER03MP CONTINENTAL HYDRAULICS PROPORTIONAL PRESSURE RELIEF VALVES PILOT OPERATED VER03MP - PROPORTIONAL PRESSURE RELIEF VAVLES PILOT OPERATED CONTINENTAL HYDRAULICS VER03MP PROPORTIONAL PRESSURE RELIEF VALVES PILOT OPERATED VER03MP - PROPORTIONAL PRESSURE RELIEF VAVLES PILOT OPERATED 5505 WEST 123RD STREET SAVAGE, MN 55378-1299 / PH: 952.895.6400

More information

Proportional pressure reducing valve, direct operated, increasing characteristic curve Type MHDRE 06 SK (high-performance)

Proportional pressure reducing valve, direct operated, increasing characteristic curve Type MHDRE 06 SK (high-performance) Proportional pressure reducing valve, direct operated, increasing characteristic curve Type MHDRE 6 SK (high-performance) RE 64655 Edition: 7.218 Replaces: 11.216 Size 6 Series 3X Maximum control pressure

More information

LOAD SENSE SECTIONS. Series 20. Directional Control Valves NEED NEW PIC VALVES STANDARD FEATURES SPECIFICATIONS

LOAD SENSE SECTIONS. Series 20. Directional Control Valves NEED NEW PIC VALVES STANDARD FEATURES SPECIFICATIONS Directional Control Valves LOAD SENSE SECTIONS NEED NEW PIC Series 20 STANDARD FEATURES Control and reduced Dead Band (20I) and Tie Rod Kits SPECIFICATIONS Pressure Rating Foot Mounting Maximum Operating

More information

SECTIONAL BODY. Model SV. Directional Control Valves VALVES STANDARD FEATURES SPECIFICATIONS. Parallel or Series Circuit Construction ...

SECTIONAL BODY. Model SV. Directional Control Valves VALVES STANDARD FEATURES SPECIFICATIONS. Parallel or Series Circuit Construction ... Directional Control Valves SECTIONAL BODY Model SV STANDARD FEATURES SPECIFICATIONS Parallel or Series Circuit Construction Foot Mounting Pressure Rating Maximum Operating Temp....... Weight Per Section......

More information

VS6M - SOLENOID OPERATED DIRECTIONAL VALVES

VS6M - SOLENOID OPERATED DIRECTIONAL VALVES CONTINENTAL HYDRAULICS VS6M SOLENOID OPERATED DIRECTIONAL VALVES 5505 WEST 123RD STREET SAVAGE, MN 55378-1299 / PH: 952.895.6400 / WWW.CONTINENTALHYDRAULICS.COM VS6M SOLENOID OPERATED DIRECTIONAL VALVES

More information

SM4-10/12/15 Servovalves Flows to 57 l/min (15 USgpm) Pressures to 210 bar (3000 psi)

SM4-10/12/15 Servovalves Flows to 57 l/min (15 USgpm) Pressures to 210 bar (3000 psi) Vickers Servo Valves SM4-10/12/15 Servovalves Flows to 57 l/min (15 USgpm) Pressures to 210 bar (3000 psi) Released 12/93 651 Introduction Vickers SM4-10/12/15 servovalves can provide system closed loop

More information

VER03M CONTINENTAL HYDRAULICS PROPORTIONAL PRESSURE RELIEF VALVES VER03M - PROPORTIONAL PRESSURE RELIEF VALVES

VER03M CONTINENTAL HYDRAULICS PROPORTIONAL PRESSURE RELIEF VALVES VER03M - PROPORTIONAL PRESSURE RELIEF VALVES CONTINENTAL HYDRAULICS VER03M PROPORTIONAL PRESSURE RELIEF VALVES 5505 WEST 123RD STREET SAVAGE, MN 55378-1299 / PH: 952.895.6400 / WWW.CONTINENTALHYDRAULICS.COM ACCURATE VER03M PROPORTIONAL PRESSURE RELIEF

More information

CLS180 Proportional Load Sensing Mobile Valve

CLS180 Proportional Load Sensing Mobile Valve Mobile valves Proportional Load Sensing, Model CLS180 350 bar 180 L/min Up to 10 sections Eaton Pro-FX TM Ready CLS180 Proportional Load Sensing Mobile Valve Overhaul manual / Trouble shooting guide Contents

More information

Directional Controls

Directional Controls Vickers Directional Controls Wet Armature Solenoid Operated Directional Control Valves Model DGV-, Series Typical Construction of a Spring-Centered DC Valve with Variable Speed Pilot Control passage Speed

More information

PRM7-04. Functional Description HA /2012. Proportional Directional Control Valves. Replaces HA /2009

PRM7-04. Functional Description HA /2012. Proportional Directional Control Valves. Replaces HA /2009 Proportional Directional Control Valves PRM7-6/ Size D () bar (6 PSI) L/min (. GPM ) Replaces /9 Digital control Compact design Operated by proportional solenoids High sensitivity and slight hysteresis

More information

Proportional Valves. Proportional Two-Stage Directional Valves

Proportional Valves. Proportional Two-Stage Directional Valves VICKERS roportional Valves roportional Two-Stage Directional Valves KHDG5V-5/7, 1 Series ressures to 3 bar ( psi) This product has been designed and tested to meet specific standards outlined in the European

More information

DL /118 ED SOLENOID OPERATED DIRECTIONAL CONTROL VALVE COMPACT VERSION SUBPLATE MOUNTING ISO p max 280 bar Q max 50 l/min

DL /118 ED SOLENOID OPERATED DIRECTIONAL CONTROL VALVE COMPACT VERSION SUBPLATE MOUNTING ISO p max 280 bar Q max 50 l/min 41 211/118 ED DL3 SOLENOID OPERATED DIRECTIONAL CONTROL VALVE COMPACT VERSION SUBPLATE MOUNTING ISO 4401-03 p max 280 bar Q max 50 l/min MOUNTING SURFACE OPERATING PRINCIPLE ISO 4401-03-02-0-05 (CETOP

More information

Housings and Miscellaneous Parts

Housings and Miscellaneous Parts Housings and Miscellaneous Parts Standard and Special Valve Housings, Orifice Disks, Orifice Sizing harts, Pilot Pistons, dapters, djustment Kits and Seal Kits ETON Vickers Screw-in artridge Valves V-VLOV-M001-E1

More information

10 FT./lbs. TORQUE FOR SOLENOID NUT MANUAL OVERIDE PIN GREY PLUG (85.3) 3.36 (74.7) SOLENOID "a" "B" PORT END (3.2) LOCATING PIN.

10 FT./lbs. TORQUE FOR SOLENOID NUT MANUAL OVERIDE PIN GREY PLUG (85.3) 3.36 (74.7) SOLENOID a B PORT END (3.2) LOCATING PIN. EDM ELECTRICAL OPTIONS: CODES B, BT or BH NFPA D size (former D) For interface pattern see Mounting Surface section. (.).9 SOL. "b" DIMENSIONS SHOWN : (MILLIMETERS) CHES SOL. "a" /- NPTF -P CONNECTOR OPTION

More information

Flow control valve range

Flow control valve range inspired hydraulics. Flow control valve range FPR102 Functional description Flow control valves of the FPR10 series are used for load independent and stepless adjusting of the operating speed of hydraulic

More information

PROPORTIONAL PRESSURE RELIEF VALVES PILOT OPERATED WITH OBE

PROPORTIONAL PRESSURE RELIEF VALVES PILOT OPERATED WITH OBE CONTINENTAL HYDRAULICS VER03MPG PROPORTIONAL PRESSURE RELIEF VALVES PILOT OPERATED WITH OBE VER03MPG - PROPORTIONAL PRESSURE RELIEF VAVLES PILOT OPERATED WITH OBE 5505 WEST 123RD STREET SAVAGE, MN 55378-1299

More information

Proportional Pressure Reducing Valve PDM08130

Proportional Pressure Reducing Valve PDM08130 Proportional Pressure Reducing Valve PDM08130 up to 80 bar up to 10 l/min Cartridge valves Control electronics Connection housings 486 1. DESCRIPTION 1.1. GENERAL According to DIN-ISO 1219, HYDAC proportional

More information

EFC. Electronically Adjustable Proportional Pressure Compensated Flow Control

EFC. Electronically Adjustable Proportional Pressure Compensated Flow Control Engineering & Manufacturing Solutions Specifications: See flow chart for capacity. 3000 psi (207 bar) rating. Weighs 8-1/2 lbs. (3.9 kg). Standard Port size #12SAE (1-1/16 12). 10-Micron Filtration Recommended.

More information

Directional Control Valves Series D111VW. General Description. Features. Performance Curves

Directional Control Valves Series D111VW. General Description. Features. Performance Curves Technical Information General valves are piloted by a D1VW valve. The valves can be ordered with position control. The minimum pilot pressure must be ensured for all operating conditions of the directional

More information

Proportional pressure relief valve, pilot-operated, with anti-cavitation function, decreasing characteristic curve Type KBVS.2DB

Proportional pressure relief valve, pilot-operated, with anti-cavitation function, decreasing characteristic curve Type KBVS.2DB Proportional pressure relief valve, pilot-operated, with anti-cavitation function, decreasing characteristic curve Type KBVS.2DB RE 18377 Edition: 11.2017 Size 2 Series B Maximum working pressure 420 bar

More information

Pilot Operated Directional Control Valves Series D1VP, D3DP, D4P, D9P, D11P

Pilot Operated Directional Control Valves Series D1VP, D3DP, D4P, D9P, D11P Characteristics Series D1VP, D3DP, D4P, D9P, D11P The D1VP is a hydraulically controlled 4/3 or 4/ way directional control valve. The valve can be operated either by the pilot ports X and Y via the subplate

More information

VED*M PROPORTIONAL PILOT OPERATED DIRECTIONAL CONTROL VALVES

VED*M PROPORTIONAL PILOT OPERATED DIRECTIONAL CONTROL VALVES CONTINENTAL HYDRAULICS VED*M PROPORTIONAL PILOT OPERATED DIRECTIONAL CONTROL VALVES 5505 WEST 123RD STREET SAVAGE, MN 55378-1299 / PH: 952.895.6400 / WWW.CONTINENTALHYDRAULICS.COM TOUGH VED*M PROPORTIONAL

More information

Pressure Compensator Valves Series R5P (SAE Flange Mounted) General Description. Features

Pressure Compensator Valves Series R5P (SAE Flange Mounted) General Description. Features Technical Information General Description Series R5P direct operated, 3-way pressure compensators can be combined with any type of fixed or adjustable flow resistor (throttle) to provide a load compensated

More information

Electronic Controls Proportional Valve Control Power Plugs

Electronic Controls Proportional Valve Control Power Plugs Electronic ontrols Proportional Valve ontrol Power Plugs EHH-AMP-70-D/J/K-* Series For use with valve types: EPV**-D-* EFV-**-0DE* ERV/**-D-* EPRV**-D-* Application Primary applications are in the control

More information

Vickers. Servo Valves. SM4-40 Servovalves. Flows to 151 l/min (40 USgpm) Pressures to 350 bar (5000 psi) Released 1/94

Vickers. Servo Valves. SM4-40 Servovalves. Flows to 151 l/min (40 USgpm) Pressures to 350 bar (5000 psi) Released 1/94 Vickers Servo Valves SM4-40 Servovalves Flows to 151 l/min (40 USgpm) Pressures to 350 bar (5000 psi) Released 1/94 654 Introduction Vickers SM4-40 servovalves can provide system closed loop control with

More information

Proportional pressure reducing valve, direct operated, increasing characteristic curve Type MHDRE 06 FK (high-performance)

Proportional pressure reducing valve, direct operated, increasing characteristic curve Type MHDRE 06 FK (high-performance) Proportional pressure reducing valve, direct operated, increasing characteristic curve Type MHDRE 06 FK (high-performance) RE 64656 Edition: 07.18 Replaces: 11.16 Size 6 Series 3X Maximum control pressure

More information

PRM7-06. Functional Description HA /2006. Proportional Directional Control Valves. Replaces HA /2002

PRM7-06. Functional Description HA /2006. Proportional Directional Control Valves. Replaces HA /2002 Proportional Directional Control Valves PRM7-6 HA 59 /6 Size D (6)...6 PSI ( bar)...6 GPM ( L/min) Replaces HA 57 / Digital control Compact design Operated by proportional solenoids High sensitivity and

More information

PRM7-06. Functional Description HA /2014. Proportional Directional Control Valves. Replaces HA /2013

PRM7-06. Functional Description HA /2014. Proportional Directional Control Valves. Replaces HA /2013 Proportional Directional Control Valves PRM7-6 / Size 6 (D ) bar (76 PSI) L/min (.6 GPM) Replaces HA 7 / Digital control Compact design Operated by proportional solenoids High sensitivity and slight hysteresis

More information

Directional Controls

Directional Controls VICKERS Directional Controls Solenoid Operated Directional Control Valves NF D05, ISO-4401-05 DG4S*-01**-5* ir Gap ype Revised 8/97 671 able of Contents DG4S*-01 Model Code..................................................................................

More information

Proportional Electro-Hydraulic Relieving and Reducing Valves

Proportional Electro-Hydraulic Relieving and Reducing Valves These valves consist of a small size but high performance EH series electro-hydraulic proportional pilot relief valve and reducing valve with relief function. The valves control the system pressure proportionally

More information

Vickers. Piston Motors. Inline Piston Motors. Fixed and Variable Displacement. Revised 5/99 691

Vickers. Piston Motors. Inline Piston Motors. Fixed and Variable Displacement. Revised 5/99 691 Vickers Piston Motors Inline Piston Motors Fixed and Variable Displacement Revised 5/99 691 Table of Contents Introduction........................................................................................

More information

p max (see table of performances) Q max (see table of performances) bar Maximum flow rate from port P to A - B - T l/min

p max (see table of performances) Q max (see table of performances) bar Maximum flow rate from port P to A - B - T l/min 41 400/117 ED E*P4 PILOT OPERATED DISTRIBUTOR SOLENOID OR HYDRAULIC (C*P4) CONTROLLED E4P4 CETOP P05 E4R4 ISO 4401-05 E5 ISO 4401-08 p max (see table of performances) Q max (see table of performances)

More information

Directional Controls

Directional Controls Vickers Directional Controls Mechanical ctuators Directional Control Valves Directional Control Valves 310 bar (4500 psi) Flows to 114 l/min (30 USgpm) NF D05, ISO-4401-05 DG1V4-01**-10 Knob Operated DG17V4-01**-10

More information

Electrically Operated Pressure Relief Cartridge, Size 16 Seated Pilot Stage, Spool Type Main Stage Series WUVPA 1...

Electrically Operated Pressure Relief Cartridge, Size 16 Seated Pilot Stage, Spool Type Main Stage Series WUVPA 1... Electrically Operated Pressure Relief Cartridge, Size 16 Seated Pilot Stage, Spool Type Main Stage Series WUVPA 1... 3 l/min, 420 bar Two pressure valve, ON / OFF or HI / LO With internal pilot drain to

More information

VED05MG CONTINENTAL HYDRAULICS PROPORTIONAL DIRECTIONAL CONTROL VALVES WITH OBE VED05MG - PROPORTIONAL DIRECTIONAL CONTROL VALVES WITH OBE

VED05MG CONTINENTAL HYDRAULICS PROPORTIONAL DIRECTIONAL CONTROL VALVES WITH OBE VED05MG - PROPORTIONAL DIRECTIONAL CONTROL VALVES WITH OBE CONTINENTAL HYDRAULICS VED05MG PROPORTIONAL DIRECTIONAL CONTROL VALVES WITH OBE 5505 WEST 123RD STREET SAVAGE, MN 55378-1299 / PH: 952.895.6400 / FAX: 952.895.6444 / WWW.CONTINENTALHYDRAULICS.COM POWERFUL

More information

ISO 4401 size 07; 315 bar (4500 psi); up to 200 L/min (53 USgpm) General Description

ISO 4401 size 07; 315 bar (4500 psi); up to 200 L/min (53 USgpm) General Description Vickers SystemStak SystemStak Valves ISO 441 size 7; 315 bar (45 psi); up to 2 L/min (53 USgpm) General Description This range of stackable hydraulic controls are designed to be mounted under a size 7

More information

Functional Symbols and Application Notes

Functional Symbols and Application Notes Functional Symbols and pplication Notes Model Types KHDG5V Shown Simplified symbol Model Types KHDG5V Shown K()FDG5V symbols identical, but omit pilot-stage LVDTs Simplified symbol T T Detailed symbol

More information

Série D3 Válvula Direcional CETOP 5 e NG 10. Catálogo HY /US

Série D3 Válvula Direcional CETOP 5 e NG 10. Catálogo HY /US Série D3 Válvula Direcional CETOP 5 e NG 10 Catálogo HY14-2502/US Catalog HY14-2502/US Introduction pplication Series D3 hydraulic directional control valves are high performance, direct operated 4-way

More information

4/2 and 4/3-Way Proportional Directional Control Valve Direct Operated

4/2 and 4/3-Way Proportional Directional Control Valve Direct Operated Electric Drives and Controls Hydraulics Linear Motion and Assembly Technologies Pneumatics Service 4/2 and 4/3-Way Proportional Directional Control Valve Direct Operated Model 4 WRA(E)B Size 6 Series 1X

More information

Electrically Operated Pressure Relief Cartridge, Size 1 Seated Design, Direct Acting Series WUVA 1LO...

Electrically Operated Pressure Relief Cartridge, Size 1 Seated Design, Direct Acting Series WUVA 1LO... Electrically Operated Pressure Relief Cartridge, Size Seated Design, Direct Acting Series WUVA LO....5 l/min, 40 bar Wet armature solenoid with high pressure core tube and slip on coil Coils can be changed

More information

VED05MJ - PROPORTIONAL DIRECTIONAL CONTROL VALVES WITH OBE & POSITION FEEDBACK

VED05MJ - PROPORTIONAL DIRECTIONAL CONTROL VALVES WITH OBE & POSITION FEEDBACK CONTINENTAL HYDRAULICS VED05MJ PROPORTIONAL DIRECTIONAL CONTROL VALVES WITH OBE & POSITION FEEDBACK VED05MJ - PROPORTIONAL DIRECTIONAL CONTROL VALVES WITH OBE & POSITION FEEDBACK 5505 WEST 123RD STREET

More information

Post-Compensated Proportional Valve CV2000LS

Post-Compensated Proportional Valve CV2000LS www.nimco-controls.com Post-Compensated Proportional Valve CV2000LS Smart Solutions... for the Future Contents Page 5 Page 6 Page 7 Page 8 Page 9 Page 10 Page 11 Page 12 Page 13 Page 14 Page 15 Page 16

More information

USA Headquarters. Dynex/Rivett Inc. 770 Capitol Drive Pewaukee, WI U.S.A. Tel: FAX:

USA Headquarters. Dynex/Rivett Inc. 770 Capitol Drive Pewaukee, WI U.S.A. Tel: FAX: SPECIFICATIONS D03 Pattern Directional Control Valves Also refer to "Directional Valve Features, Selection and Operating Recommendations" (dynexdcvoperating.pdf) CONTACT INFORMATION USA Headquarters Dynex/Rivett

More information

Pilot Operated Pressure Relief Valve Series R5V (Denison)

Pilot Operated Pressure Relief Valve Series R5V (Denison) Characteristics Pilot operated pressure relief valves series R5V have a similar design to the subplate mounted R4V series. The SAE flanges allow to mount the valves directly on the outlet flanges of pumps

More information

Sepehr Hydraulic Asia

Sepehr Hydraulic Asia Vickers Solenoid Operated Directional Valves Explosion Proof ATEX, UL, CSA Sepehr Hydraulic Asia DG4V-3S, X4 & X5 DG4V4-1, X5 Table of Contents Introduction General Description... 3 Features and Benefits...

More information

29 158/ Proportional Pressure Relief Valve Models DBE and ZDBE, Series 1X. Ordering code DBE 6 1X G24 1/ PSI (315 bar)

29 158/ Proportional Pressure Relief Valve Models DBE and ZDBE, Series 1X. Ordering code DBE 6 1X G24 1/ PSI (315 bar) RA 29 58/6.98 Proportional Pressure Relief Valve Models DBE and ZDBE, Series X Size 6 (R 3)... 46 PSI (35 bar)... 8 GPM (3 L/min) RA 29 58/6.98 Replaces: 5.94 Valve for limiting system pressure Operation

More information

Pilot Operated Directional Control Valves Series D31DW, D31NW, D*1VW

Pilot Operated Directional Control Valves Series D31DW, D31NW, D*1VW Characteristics The pilot operated valves are available in 4 sizes: D31DW NG10 (standard) D31NW NG10 (high flow) D41VW NG16 D81VW NG5 (for port diameter up to 6 mm) D91VW NG5 (for port diameter up to 3

More information

DSE3B /118 ED DIRECTIONAL VALVE WITH PROPORTIONAL CONTROL SERIES 10 SUBPLATE MOUNTING ISO p max 350 bar Q max 40 l/min

DSE3B /118 ED DIRECTIONAL VALVE WITH PROPORTIONAL CONTROL SERIES 10 SUBPLATE MOUNTING ISO p max 350 bar Q max 40 l/min 83 215/118 ED DSE3B DIRECTIONAL VALVE WITH PROPORTIONAL CONTROL SUBPLATE MOUNTING ISO 4401-03 p max 350 bar Q max 40 l/min MOUNTING INTERFACE OPERATING PRINCIPLE ISO 4401-03-02-0-05 (CETOP 4.2-4-03-350)

More information

29 160/ Proportional Pressure Relief Valve Model DBE, (Series 5X) Ordering Code DBE 5X Y G24 1/ PSI (350 bar)

29 160/ Proportional Pressure Relief Valve Model DBE, (Series 5X) Ordering Code DBE 5X Y G24 1/ PSI (350 bar) Size 10, 25 Proportional Pressure Relief Valve Model DE, (Series 5X)... 5100 PSI (350 bar)... 106 GPM (400 L/min) R 29 160/06.98 R 29 160/06.98 Replaces: 05.94 Operation by means of proportional solenoid

More information

Proportional pressure relief valve, directly operated, rising characteristic curve

Proportional pressure relief valve, directly operated, rising characteristic curve Proportional pressure relief valve, directly operated, rising characteristic curve RE 1139-0/09.07 Replaces: 0.05 1/1 Type KBPS.A (High-Performance) Component series A Maximum operating pressure 0 bar

More information

VER*SP CONTINENTAL HYDRAULICS PROPORTIONAL PILOT RELIEF VALVES VER*SP - PROPORTIONAL PILOT RELIEF VALVES

VER*SP CONTINENTAL HYDRAULICS PROPORTIONAL PILOT RELIEF VALVES VER*SP - PROPORTIONAL PILOT RELIEF VALVES CONTINENTAL HYDRAULICS VER*SP PROPORTIONAL PILOT RELIEF VALVES 5505 WEST 123RD STREET SAVAGE, MN 55378-1299 / PH: 952.895.6400 / WWW.CONTINENTALHYDRAULICS.COM DURABLE VER*SP PROPORTIONAL PILOT RELIEF VALVES

More information

LOGIC POPPET VALVES AND CARTRIDGE MANIFOLD SYSTEMS

LOGIC POPPET VALVES AND CARTRIDGE MANIFOLD SYSTEMS Fluid Power Specialist Since 1948 LOGIC POPPET VALVES AND CARTRIDGE MANIFOLD SYSTEMS Copyright 2018, Almo Manifold & Tool Co. All rights reserved. All attempts have been made to make the information in

More information