SYSCOIL 2. Range of fan coil units. Chillers & Heat Pumps Water terminals Roof tops Close control Water source heat pumps Direct expansion

Size: px
Start display at page:

Download "SYSCOIL 2. Range of fan coil units. Chillers & Heat Pumps Water terminals Roof tops Close control Water source heat pumps Direct expansion"

Transcription

1 Chillers & Heat Pumps Water terminals Roof tops Close control Water source heat pumps Direct expansion SYSCOIL 2 Range of fan coil units from 0.5 to 9.1 kw from 0.8 to 12.6 kw

2 SYSCOIL 2 Innovation for an optimum comfort Easy to install, improvement of sound levels/performances and Aqu@Net electronic control are the key developments carried on our new fan coil units. The SysCoil 2 units range is issued from that development striving to meet customers wishes and advices. The design of the grille, associated with a refined casing allows a harmonious and smart integration of the fan coil units in every kind of interiors. They are the ideal solution to air-condition agreeably and efficiently, flats, hotels, hospitals, offices and other premises, all year long. VC Vertical console HC Ceiling exposed Air flow from 95 to1397 m 3 /h Capacity from 0.5 to 9.1 kw for cooling Capacity from 0.8 à 12.6 kw for heating Very low sound level VN Vertical concealed HN Available with EC motor Ceiling concealed A design adapted to your comfort A design dedicated to your needs Systemair Products aim to be tuned to the market and costumers wishes. Thus, each product is designed and conceived to answer to your needs. Dedicated design for vertical installation Dedicated design for horizontal installation Robust design, easy installation Systemair offers you a range with a robust design for an easy and safe installation. A design dedicated to energy savings Full range available with EC fans High efficiency EC motors with low electrical consumption for significant energy savings Fitted with ECospeed 3 interface card (supplied as standard) for a 3-speed optimized running Energy label up to A class Very large working range External drain pan included as a standard Monobloc painted drain pan for better robustness

3 Quick selection guide 4 models : VC, HC, VN, HN 8 sizes : from 10 to 80 (air flow from 95 to 1397 m 3 /h) 3 versions : 2 pipes, 2 pipes/2 wires or 4 pipes 2 types of fans : AC (Syscoil 2 STD) or EC (Syscoil 2 EC) Configurations : with or without cabinet / Vertical or Horizontal SysCoil 2 STD - 2 pipes Sizes Capacities at middle speed (kw) Acoustic (at middle speed) Air flow Pressure 10 0,9 1,3 NR m³/h 0-30 Pa 20 1,1 1,4 NR m³/h 0-30 Pa 30 1,9 2,4 NR m³/h 0-30 Pa 40 2,1 2,7 NR m³/h 0-30 Pa 50 3,1 3,9 NR m³/h 0-40 Pa 60 4,2 4,0 NR m³/h 0-40 Pa 70 5,8 7,4 NR m³/h 0-40 Pa 80 6,6 9,2 NR m³/h 0-40 Pa Other models of water terminals KOG LN 9-18 (Cassette) kw kw EC Motor Ductys kw kw EC Motor KOG LN (cassette) kw kw EC Motor VH kw kw Hawair kw kw

4 Innovative components & control range High performance components Fans Available with AC and EC fan High quality 100% of the units are factory tested Coils 2 or 3 rows according to the mode Individually tested for leakage at 30 bars Valves 2 ways or 3 ways + bypass Innovative control range Aqu@net Electronic control Units provided with an ergonomic and discrete remote control that can be loose or integrated on the fan coil unit. All settings are made in the factory, so there is no needs to set anything on site. This innovating control offers, as a standard, a master/slave function up to 15 units from one single remote control. Other features like window contact, occupied/unoccupied, antifreeze modes are integrated without any additional cost. RCL remote control An elegant design to be integrated in every kind of environment The Syscoil 2 range is designed to be integrated in a harmonious and smart way into: Offices Hotels Administrations Industries Sysoft, the online selection tool by SYSTEMAIR AC Thanks to our online selection tool named Sysoft, select and dimension precisely and quickly, by yourself, THE water terminal you need.

5 Technical data SysCoil 2 STD (AC fans) Sizes Capacities - 2 Pipes S1 / S3 / S5 S1 / S3 / S5 S1 / S3 / S5 S1 / S3 / S5 S1 / S3 / S5 S1 / S3 / S5 S1 / S3 / S5 S1 / S3 / S5 Cooling (1) Total cooling capacity W 590/930/ 1290 Sensible capacity W 470/750/ 1050 Water flow l/h 102/161/ 222 Water pressure drop kpa 2.9/6.6/ 11.9 Heating (2) Heating capacity W 810/1300/ 1810 Capacities - 4 Pipes Total cooling capacity W 490/800/ 1110 Cooling (1) Heating (3) Sensible capacity W 390/640/ 900 Water flow l/h 85/137/ 192 Water pressure drop kpa 2.1/4.9/ 9.1 Heating capacity W 830/1240/ 1650 Water flow l/h 71/107/ 142 Water pressure drop kpa 1/1.9/ /1100/ /830/ /189/ /3.3/ /1390/ /950/ /720/ /163/ /2.6/ /1380/ /118/ /2.1/ /1950/ /1710/ /335/ /9.9/ /2360/ /1760/ /1550/ /303/ /8.3/ /2/ /192/ 3.8/6.6/ /2140/ /1620/ /368/ /14/ /2710/ /1900/ /1440/ /327/ /11.5/ /2660/ /229/ /10.1/ /3070/ /2160/ /528/ /13/ /3940/ /2790/ /1970/ /480/ /10.9/ /3760/ /324/ /16.8/ /4180/ /2960/ /721/ /25.2/ /3970/ /3830/ /2700/ /660/ /21.3/ /3580/ /308/ /18.5/ /5840/ /4280/ /1006/ /13.9/ /7370/ /5260/ /3840/ /906/ /11.3/ /5900/ /508/ /41.1/ /6650/ /4930/ /1146/ /22.6/ /9250/ /6490/ /4790/ /1117/ /21.7/ /9440/ /813/ /31.9/ 48.1 Sound Levels - 2 Pipes Sound power level db(a) 33/41/47 32/44/51 31/45/53 29/46/53 36/48/57 40/52/58 46/59/63 52/57/66 Sound pressure level (4) db(a) 17/25/31 16/28/35 15/29/37 13/30/37 20/32/41 24/36/42 30/43/47 36/41/50 NR (4) db(a) 11/16/22 6/21/26 9/23/31 6/23/27 11/23/31 16/29/34 22/34/36 27/34/45 Sound Levels - 4 Pipes Sound power level db(a) 33/41/47 32/44/51 31/45/53 29/46/53 36/48/57 40/52/58 46/59/63 52/57/66 Sound pressure level (4) db(a) 17/25/31 16/28/35 15/29/37 13/30/37 20/32/41 24/36/42 30/43/47 36/41/50 NR (4) db(a) 11/16/22 6/21/26 9/23/31 6/23/27 11/23/31 16/29/34 22/34/36 27/34/45 Fans Number Airflow - 2 Pipes m³/h 111/190/ /179/ /388/ /356/ /486/ /640/933 Airflow - 4 Pipes m³/h 95/168/253 89/161/ /366/ /333/ /466/ /614/ /893/ /859/ /936/ /905/ 1370 Electrical Data - 230V / 1~ / 50Hz - 230V / 1~ / 60Hz Fan consumption - 2 pipes W 14/24/36 14/23/35 24/50/81 18/39/59 33/57/80 39/76/111 60/114/161 90/112/188 Fan consumption - 4 pipes W 14/24/36 14/23/34 24/50/80 18/39/58 33/56/78 39/75/110 60/113/159 90/112/188 Fan consumption - 2 pipes (EC fans) W 8/14/41 8/15/41 6/19/46 2/12/43 2/24/46 2/30/54 12/45/77 23/42/108 Fan consumption - 4 pipes (EC fans) W 8/14/39 8/15/40 6/18/45 2/12/41 2/23/44 2/28/52 12/44/74 22/41/116 Electrical heater (max) W / / / / / /3000 Water connections Type Gas female threaded Cooling coil inches 1/2 1/2 1/2 1/2 1/2 1/2 3/4 1/2 Heating coil inches 1/2 Dimensions (LxWxH) VN HN mm mm VC mm HC mm 677 x x x 430 x 766 x x 477 x x x x 430 x 766 x x 477 x x x x 430 x 951 x x 477 x x x x 430 x 1136 x x x x x 430 x 1321 x x x x x 430 x 1506 x x x x x 530 x 1321 x x x x x 530 x 1508 x x 578 Weight VC / HC - 2 pipes kg , VC / HC - 4 pipes kg , VN / HN - 2 pipes kg , VN / HN - 4 pipes kg , (1) According to Eurovent standard. Air: 27 C DB/19 C WB, Water in: 7 C/12 C. (2) According to Eurovent standard. Air: 20 C, Water in: 50 C, same water flow as in cooling. (3) According to Eurovent standard. Air: 20 C, Water in: 70 C/60 C. (4) Informative data, considering a sound attenuation of the room and installation of 16dBA.

6 Systemair AC SAS Route de Verneuil Tillières-sur-Avre France Tel Fax Systemair srl Via XXV Aprile, Barlassina (MB) Italy Tel Fax Systemair AC SAS LEAF SYSCOIL 2-6P-S-1GB(07.16)

Water terminals From 360 to 1598 m 3 /h. From 1.3 to 9.6 kw. SysQuare. Chilled water cassettes. From 1.1 to 14.0 kw

Water terminals From 360 to 1598 m 3 /h. From 1.3 to 9.6 kw. SysQuare. Chilled water cassettes. From 1.1 to 14.0 kw Water terminals From 360 to 1598 m 3 /h SysQuare Chilled water cassettes From 1.3 to 9.6 kw From 1.1 to 14.0 kw SysQuare The best way to combine low noise and energy savings 6 sizes (20, 30, 40, 50, 60

More information

Water terminals from 91 to 1548 m 3 /h. from 0,5 to 9,6 kw. SysCoil Comfort. Floor and ceiling fan coil units. from 0,6 to 13,6 kw

Water terminals from 91 to 1548 m 3 /h. from 0,5 to 9,6 kw. SysCoil Comfort. Floor and ceiling fan coil units. from 0,6 to 13,6 kw Water terminals from 91 to 1548 m 3 /h SysCoil Comfort Floor and ceiling fan coil units from 0,5 to 9,6 kw from 0,6 to 13,6 kw SysCoil Comfort Innovation for an optimum comfort ErP 2018 TERTIAIRY H 3 /h

More information

SysCoil 2. Fan Coil Units Models SVC, SVN, SHC, SHN to 8.75kW to 4.90kW. 94 to /h

SysCoil 2. Fan Coil Units Models SVC, SVN, SHC, SHN to 8.75kW to 4.90kW. 94 to /h SysCoil Fan Coil Units Models SVC, SVN, SHC, SHN 0.79 to 8.75kW 0.49 to 4.90kW 94 to 930 3 /h SysCoil Quality, efficiency and reliability Vertical console units with cabinet, SVC type SVC vertical console

More information

Air Conditioning Selection Guide

Air Conditioning Selection Guide Fans Air Handling Units Air Distribution Products Air Conditioning Fire Safety Air Curtains and Heating Products Tunnel Fans Air Conditioning Selection Guide Light Commercial, Commercial and Industrial

More information

Chiller Close Control Water terminals SYSCASSETTE. Water cassette units

Chiller Close Control Water terminals SYSCASSETTE. Water cassette units Chiller Close Control Water terminals SYSCASSETTE Water cassette units SYSCASSETTE Water cassette Available accessories Available in 8 different sizes and 2 versions. Due to its square design these units

More information

Total cooling capacity kw Total heating capacity kw Features

Total cooling capacity kw Total heating capacity kw Features Room Fan Coils Idrofan Quality Management Systems 42N Total cooling capacity 0.75-6.35 kw Total heating capacity 0.60-9.50 kw The new generation 42N_S product range combines aesthetic and attractive design

More information

Engineering Data Manual. New : available with EC motor. High Static Pressure Ductable Fan Coil Unit. Models 07 to to 4650 m 3 /h

Engineering Data Manual. New : available with EC motor. High Static Pressure Ductable Fan Coil Unit. Models 07 to to 4650 m 3 /h Engineering Data Manual New : available with EC motor VH High Static Pressure Ductable Fan Coil Unit Models 07 to 27 800 to 4650 m 3 /h General Characteristics Presentation On model VH 07, coils have 4

More information

Innovative, High Performance, Quiet Units.

Innovative, High Performance, Quiet Units. Fan Coil Units Innovative, High Performance, Quiet Units. Technical Brochure TM AQF-A.4GB Date : January 2006 Supersedes : TM AQF-A.3GB/04.04 Quality, efficiency and reliability, built into every unit...

More information

Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Water terminals SYSCOIL. Centrifugal fan coil units

Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Water terminals SYSCOIL. Centrifugal fan coil units Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Water terminals SYSCOIL Centrifugal fan coil units SYSCOIL Fan coil units Compact, slim fan coil units. Available

More information

42N. Room Fan Coils PRODUCT SELECTION DATA. MAINTENANCE INSTRUCTIONS Simpified installation & large options choice

42N. Room Fan Coils PRODUCT SELECTION DATA. MAINTENANCE INSTRUCTIONS Simpified installation & large options choice PRODUCT SELECTION DATA Extremely quiet operation INSTALLATION, OPERATION AND Low Energy Consumption MAINTENANCE INSTRUCTIONS Simpified installation & large options choice Self regulated PTC electrical

More information

Chiller, Close control and Water terminals. Air Conditioning. Light Commercial, Commercial and Industrial

Chiller, Close control and Water terminals. Air Conditioning. Light Commercial, Commercial and Industrial Chiller, Close control and Water terminals Air Conditioning Light Commercial, Commercial and Industrial Water Terminals 133 Water Terminals Fan coils & Cassette Centrifugal fan-coil SYSCOIL Ductable fan-coil

More information

42GW. Hydronic Cassette Fan Coil Units PRODUCT SELECTION DATA INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS EASY INSTALLATION

42GW. Hydronic Cassette Fan Coil Units PRODUCT SELECTION DATA INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS EASY INSTALLATION PRODUCT SELECTION DATA EASY INSTALLATION INSTALLATION, OPERATION AND CENTRAL AIR DIFFUSION MAINTENANCE INSTRUCTIONS LOW ENERGY CONSUMPTION IMPROVED COMFORT ELEGANT AIR INLET GRILLE EXTREMELY QUIET OPERATION

More information

Residential comfort unit OperatiOn 2 models. new builds or existing properties. 5 operating modes COnfOrmity COmpOnents

Residential comfort unit OperatiOn 2 models. new builds or existing properties. 5 operating modes COnfOrmity COmpOnents Residential HEE motor Silent operation Heating capacity: 200 W to 4 kw Cooling capacity: 100 W to 3 kw Operation is CIAT's residential. This vertical cased unit, designed for heating and cooling, is available

More information

Chiller. VLC 524 to Air Cooled Condensing Units Engineering Data Manual. 154 to 347 kw

Chiller. VLC 524 to Air Cooled Condensing Units Engineering Data Manual. 154 to 347 kw Chiller VLC 524 to 1204 Air Cooled Condensing Units Engineering Data Manual 154 to 347 kw Outstanding Strength Points Units with R410A refrigerant (it will be the real replacement of R22). As near azeotropic

More information

Compresseur scroll. Refrigerant R410A SYSAQUAC. Air Cooled Condensing Units Models 25 to to 136.0kW

Compresseur scroll. Refrigerant R410A SYSAQUAC. Air Cooled Condensing Units Models 25 to to 136.0kW Compresseur scroll Refrigerant R410A SYSAQUAC Air Cooled Condensing Units Models 25 to 125 32.0 to 136.0kW SYSAQUA Condensation 1 Key Points R410A refrigerant, Units are optimized for partial load operation,

More information

Chiller. AQSL 2612 to Air Cooled Chillers With or without total heat recovery Engineering Data Manual. 602 to 908 kw

Chiller. AQSL 2612 to Air Cooled Chillers With or without total heat recovery Engineering Data Manual. 602 to 908 kw Chiller AQSL 2612 to 4212 Air Cooled Chillers With or without total heat recovery Engineering Data Manual 602 to 908 kw Features & Strength Points Sturdy structure, vibration tests and FEM structural analysis.

More information

CENTRIFUGAL FAN COIL UNIT VCE

CENTRIFUGAL FAN COIL UNIT VCE CENTRIFUGAL FAN COIL UNIT VCE 0,51 kw 11,00 kw 0,85 kw 23,75 kw 129 m 3 /h 2003 m 3 /h VCE DESIGN QUALITY COMFORTRELIABILITY 3VERSION12 SIZE DESIGN VCEx0 vertical with cabinet Air intake: bottom vertical

More information

Guide Specifications. General. Casing. Coil/Drain pan. Fan/Motor

Guide Specifications. General. Casing. Coil/Drain pan. Fan/Motor Guide Specifications General CR-A series ducted concealed chilled water fan coil units have an air flow range from 45 to 3060 cubic meters per hour with a capacity range from kw up to 9 kw. The CR-A series

More information

Air conditioning. Residential and Light Commercial

Air conditioning. Residential and Light Commercial Fans Air Handling Units Air Distribution Products Air Conditioning Fire Safety Air Curtains and Heating Products Tunnel Fans Air conditioning Residential and Light Commercial Systemair Trust We consider

More information

42C/D SERIES Ducted Chilled Water Fan Coil Unit With District Cooling Application

42C/D SERIES Ducted Chilled Water Fan Coil Unit With District Cooling Application 42C/D SERIES Ducted Chilled Water Fan Coil Unit With District Cooling Application MAXIMIZING PERFORMANCE, ENERGY SAVINGS & COMFORT MODEL NUMBER NOMENCLATURE 4 2 C E T 0 0 3 4 7 0 1 2 5 42 series CISB Code

More information

Midea 50Hz AC Fan Coil Unit 2-Pipe Floor-standing Series Technical Service Manual

Midea 50Hz AC Fan Coil Unit 2-Pipe Floor-standing Series Technical Service Manual Midea 50Hz AC Fan Coil Unit 2-Pipe Floor-standing Series Technical Service Manual Midea reserves the right to discontinue, or change specification or designs at any time without notices and without incurring

More information

NEW. Wall controls. YFCN Fan Coil Units. Technical Guide - for internal distribution only

NEW. Wall controls. YFCN Fan Coil Units.     Technical Guide - for internal distribution only NEW Wall controls Fan Coil Units www.euroventcertification.com www.certiflash.com Technical Guide for internal distribution only CONTENTS Construction Page 4 s Page 5 Dimension, Weight, Water content Page

More information

Fan Coil Units. Technical Data ECDEN FWL-DT/DF

Fan Coil Units. Technical Data ECDEN FWL-DT/DF Fan Coil Units Technical Data ECDEN10-400 FWL-DT/DF Fan Coil Units Technical Data ECDEN10-400 FWL-DT/DF TABLE OF CONTENTS FWL-DT/DF 1 Features.............................................................

More information

Flex Series. Modular Air-cooled Chillers and Heat Pumps Cooling Capacity kw Heating Capacity kw

Flex Series. Modular Air-cooled Chillers and Heat Pumps Cooling Capacity kw Heating Capacity kw Flex Series Modular Air-cooled Chillers and Heat Pumps Cooling Capacity 38-329 kw Heating Capacity 47-354 kw 1 Trane Flex Series Modular air/water chillers and heat pumps units with axial fans and scroll

More information

High Static Pressure Duct Fan Coil Unit

High Static Pressure Duct Fan Coil Unit MCAC-KTSM-2012-03 High static pressure ducted FCU High Static Pressure Duct Fan Coil Unit 1. Introduction... 2 2. Nomenclature... 2 3. Product Schedule... 3 4. External Appearance... 3 5. Features... 4

More information

Product Catalogue ARMONIA Providing indoor climate comfort

Product Catalogue ARMONIA Providing indoor climate comfort Product Catalogue ARMONIA Providing indoor climate comfort ARMONIA 1,3-11 kw Water cassette Main applications Light commercial buildings Offi ces Shops General description Why this choice? Silent operation

More information

air handling units YAH

air handling units YAH air handling units YAH C: 380 5V-3Ph-50Hz D: 0V-3Ph-0Hz E: 380V-3Ph-0Hz F: 30V-3Ph-0Hz None:380V-3Ph-50Hz 3 If the unit has TiO, evaporative humidifier or split coil (cooling+ing) option, the external

More information

BASTONE (dual) fancoil Units

BASTONE (dual) fancoil Units BASTONE (dual) fancoil Units Technical information manual Western Airconditioning B.V. Tel. +31 (0) 33 247 78 00 www.western.nl 1-INTRODUCTION..3 2- WORKING CONDITION LIMITS...3 3- COANDA EFFECT 3 4- KEY

More information

42CET/ 42CED Series Chilled Water Fan Coil Unit Furred-in Ceiling Model 300 to 1400 cfm Electric heater option

42CET/ 42CED Series Chilled Water Fan Coil Unit Furred-in Ceiling Model 300 to 1400 cfm Electric heater option 42CET/ 42CED Series Chilled Water Fan Coil Unit Furred-in Ceiling Model 0 to 10 cfm Electric heater option 42DC/ 42DCD Series Chilled Water Fan Coil Unit Furred-in Ceiling Model 0 to 00 cfm Electric heater

More information

Fan coil units MAJOR 2 CV/CH

Fan coil units MAJOR 2 CV/CH CH 41 D CV 1 D MAJOR 2: Design and performance HEE impeller for increased performance Motor optional MAJOR 2 is a non-independant chilled and/or hot water supplied air conditioning Comfort unit for the

More information

Midea Air Handling Unit

Midea Air Handling Unit Midea Air Handling Unit Floor mounted 3000CFM ---25000CFM Vertical mounted 3000CFM ---25000CFM Ceiling suspended 1000CFM ---9000CFM Midea reserves the right to improve the product and technology without

More information

Carisma The Ultra Quiet Fan Coil

Carisma The Ultra Quiet Fan Coil Carisma The Ultra Quiet Fan Coil Air Conditioning Carisma / CRR Fan Coil Units Quality management systems SO 900 Cert. n 0545/4 www.euroventcertification.com www.certiflash.com CONTENTS Construction ()

More information

VLH 504 to Air-to-Water Reverse Cycle Heat Pumps. 126 to 294 kw. 133 to 307 kw

VLH 504 to Air-to-Water Reverse Cycle Heat Pumps. 126 to 294 kw. 133 to 307 kw Air-to-Water Reverse Cycle Heat Pumps VLH 504 to 1204 126 to 294 kw 133 to 307 kw Technical Brochure TM VLH-N.3GB Date : June 2005 Supersedes : TM VLH-N.2GB/07.04 Specifications Advantages Range extension

More information

TECHNICAL MANUAL SOFFIO Ducted units

TECHNICAL MANUAL SOFFIO Ducted units TECHNICAL MANUAL SOFFIO Ducted units Page 1 INDEX 1-INTRODUCTION... 4 2-OPERATING LIMITS... 4 3- KEY TO READING CODES... 5 4-TECHNICAL SPECS... 6 5-TECHNICAL DATA (AC motors)... 7 5.1-Unit 2 pipes with

More information

Driving and Connecting Globally. Fan Coil Unit. Model : PHW-K Size : 510CMH~2720CMH. Made in Taiwan

Driving and Connecting Globally. Fan Coil Unit. Model : PHW-K Size : 510CMH~2720CMH. Made in Taiwan Driving and Connecting Globally Fan Coil Unit : PHW-K Size : 510CMH~2720CMH Made in Taiwan Features Superior low-height design. Stainless steel drain pan for condensate and corrosion protection. Flexibe-reverse

More information

Fan coil units. Why choose Daikin fan coil units? 540 Products overview 542. Options & accessories 560. Round flow cassette 544 FWC-BT/BF 544

Fan coil units. Why choose Daikin fan coil units? 540 Products overview 542. Options & accessories 560. Round flow cassette 544 FWC-BT/BF 544 Fan coil units Why choose Daikin fan coil units? 540 Products overview 542 Round flow cassette 544 FWC-BT/BF 544 4-way blow ceiling mounted cassettes 545 FWG-AT/AF 545 FWF-BT/BF 546 FWF-CT 547 Floor standing

More information

Cert. n 0545 Carisma CRC Fan Coil Unit The Ultra Quiet Fan Coil TECHNICAL GUIDE

Cert. n 0545 Carisma CRC Fan Coil Unit The Ultra Quiet Fan Coil TECHNICAL GUIDE Cert. n 0545 www.euroventcertification.com Carisma Fan Coil Unit The Ultra Quiet Fan Coil TECHNCAL GUDE Carisma CONTENTS Construction Page 4 s Page 5 Dimension, Weight, Water content Page 6 EUROENT certification

More information

Performance Data. Fan Performance Curves - FDCLP2 with ECM. Unit Size Unit Size FDCLP2 Fan Curves-1 v001

Performance Data. Fan Performance Curves - FDCLP2 with ECM. Unit Size Unit Size FDCLP2 Fan Curves-1 v001 Fan Performance Curves - FDCLP2 with ECM Unit Size 1 1 2 3 4 5 6 7 8 9 1 11 Unit Size 2 1 2 3 4 5 6 7 8 9 1 11 12 No Coil 1 Row 2 Row FDCLP2 Fan Curves-1 v1 Fan Performance Curves - FDCLP2 with ECM Unit

More information

MAJOR 2 NCH. Ductable units. High pressure and high capacity ductable units RANGE NCH Y NCH NCH I COADIS COMBI. Motor optional

MAJOR 2 NCH. Ductable units. High pressure and high capacity ductable units RANGE NCH Y NCH NCH I COADIS COMBI. Motor optional Y + U I COADIS COMBI High pressure and high ductable units Motor optional is a non independent air conditioning terminal unit for heating and cooling offices and hotels. With reduced dimensions and designed

More information

PRODUCT CATALOGUE CHILLED WATER CASSETTE CWC

PRODUCT CATALOGUE CHILLED WATER CASSETTE CWC PRODUCT CATALOGUE CHILLED WATER CASSETTE CWC English/09-2003 CHILLED WATER CASSETTE! INTRODUCTION TO THE RANGE The units are available in the following versions:! 2 pipes! 2 pipes - 2 wires (electrical

More information

Capacity Tables. Cooling Capacity: Cooper&Hunter Wall Mounted FCU

Capacity Tables. Cooling Capacity: Cooper&Hunter Wall Mounted FCU Cooling Capacity: Remark: EWT: Enter Water Temp. ( ); Δt: Temperature Difference ( ) DB: Dry Bulb Temp. ( ); WB: Wet Bulb Temp. ( ); TC: Total Cooling Capacity (kw); SC: Sensible Cooling Capacity (kw);

More information

CMTE. Tangential Fan Coil Series with Electronic Controlled Motor

CMTE. Tangential Fan Coil Series with Electronic Controlled Motor Tangential Fan Coil Series with Electronic Controlled Motor Designed by Very Low Electric Energy Consumption High Efficiency Extremely Low Noise Level Infra Red Remote Control Step-less Fan Speed Control

More information

Chilled Water Vertical Fan Coils

Chilled Water Vertical Fan Coils PRODUCT MANUAL Chilled Water Vertical Fan Coils Models: FWMW-C FWMW-H FWCW-C FWCW-H INDEX Vertical Fan Coil page 2 General Characteristics page 3 Technical data page 7 Sound Level page 9 Operating Limits

More information

Air Curtains for Revolving Doors

Air Curtains for Revolving Doors Air Curtains for Revolving Doors Air curtains for revolving doors ROTOWIND The design of buildings with revolving doors that integrate with the environment is a common solution when the entrance has adverse

More information

42NL & 42NH. Hydronic Ducted Fan Coil Units PRODUCT SELECTION DATA. Modular Horizontal ducted unit. Extremely quiet operation. Low Energy Consumption

42NL & 42NH. Hydronic Ducted Fan Coil Units PRODUCT SELECTION DATA. Modular Horizontal ducted unit. Extremely quiet operation. Low Energy Consumption PRODUCT SELECTION DATA Modular Horizontal ducted unit Extremely quiet operation Low Energy Consumption Flexibility for simplified installation Improved comfort Efficient Indoor Air Quality Hydronic Ducted

More information

Chiller assembly line Testing Lab. Painting line CNC machine

Chiller assembly line Testing Lab. Painting line CNC machine Shandong Vicot Air Conditioning Co., Ltd. is one of the major players in the Chinese air conditioning industry, specialized in central air conditioning products. Its new industrial park covers a total

More information

42NL & 42NH. Hydronic Ducted Fan Coil Units PRODUCT SELECTION DATA. Modular Horizontal ducted unit. Extremely quiet operation

42NL & 42NH. Hydronic Ducted Fan Coil Units PRODUCT SELECTION DATA. Modular Horizontal ducted unit. Extremely quiet operation PRODUCT SELECTION DATA Modular Horizontal ducted unit Extremely quiet operation Low Energy Consumption Flexibility for simplified installation Improved comfort Effcient Indoor Air Quality Hydronic Ducted

More information

Modular Air Handling. Up to 3,500 Litres / sec. Low profile & Plant room application. Draft. Version. Second Edition A-. AirDesign 2015 AirDesign 2016

Modular Air Handling. Up to 3,500 Litres / sec. Low profile & Plant room application. Draft. Version. Second Edition A-. AirDesign 2015 AirDesign 2016 Modular Air Handling U n i t R a n g e Up to 3,500 Litres / sec Low profile & Plant room application AirDesign 2015 AirDesign 2016 Second Edition Draft Version A-. Air Design is a proud Australian based

More information

NEW Slimpak EC Box Fan (SLPT EC)

NEW Slimpak EC Box Fan (SLPT EC) NEW Slimpak EC Box Fan (SLPT EC) Compact low profile design Duct Sizes 100 500mm Performance - Airflow 0.01 to 1.2m 3 /s, Pressure up to 650Pa Latest energy saving EC/DC motors Internal mounting IPX2 Manufactured

More information

Air-Cooled Liquid Chiller with integrated hydraulic module

Air-Cooled Liquid Chiller with integrated hydraulic module Air-Cooled Liquid Chiller with integrated hydraulic module Cooling only: CGAN 200-250 - 300-400 - 450-490 - 500-600 - 700-800 - 900-925 Reversible: CXAN 200-250 - 300-400 - 450-490 - 500-600 - 700-800

More information

New standard decorative generation

New standard decorative generation SMART Air Curtain SMART New standard decorative generation Based on the range of standard WINDBOX series and incorporating the contemporary elegance and rounded shapes of DECO air curtains, it comes the

More information

Chiller. AQL/AQH 40 to 75. Air Cooled Water Chillers Cooling Only and Heat Pump Engineering Data Manual to 77.2 kw to 75.

Chiller. AQL/AQH 40 to 75. Air Cooled Water Chillers Cooling Only and Heat Pump Engineering Data Manual to 77.2 kw to 75. Chiller AQL/ to 75 Air Cooled Water Chillers Only and Heat Pump Engineering Data Manual.0 to 75.8 kw 39.9 to 77.2 kw Outstanding Strength Points R410A Refrigerant. New simpler refrigerant circuit layout.

More information

Fan Coil Units. Technical Data. Conceiled ceiling unit ECDEN FWB-BT

Fan Coil Units. Technical Data. Conceiled ceiling unit ECDEN FWB-BT Fan Coil Units Technical Data Conceiled ceiling unit ECDEN10-400 FWB-BT Fan Coil Units Technical Data Conceiled ceiling unit ECDEN10-400 FWB-BT TABLE OF CONTENTS FWB-BT 1 Features.............................................................

More information

HRS. Very high efficiency heat recovery units. from 300 to m³/h >90 % WITH HIGH EFFICIENCY HEAT RECOUPERATOR

HRS. Very high efficiency heat recovery units. from 300 to m³/h >90 % WITH HIGH EFFICIENCY HEAT RECOUPERATOR 4 Lmf Clima 6 FERRARO GROUP HRS Very high efficiency heat recovery units WITH HIGH EFFICIENCY HEAT RECOUPERATOR from 3 to 4. m³/h Air-handling unit designed and manufactured for nonresidential applications,

More information

VLS (Cooling Only) VLH (Heat Pump Version) VLR (Total Heat Recovery Version)

VLS (Cooling Only) VLH (Heat Pump Version) VLR (Total Heat Recovery Version) R u Air Cooled Water Chillers VLS (Cooling Only) VLH (Heat Pump Version) VLR (Total Heat Recovery Version) Models 524 to 1204 137 to 308 kw 150 to 336 kw Engineering Data Manual EDM VL410-W.2GB Date :

More information

Maestro. High Pressure Fan Coil Unit with Asynchronous Motor

Maestro. High Pressure Fan Coil Unit with Asynchronous Motor Maestro High Pressure Fan Coil Unit with Asynchronous Motor The Maestro high pressure fan coils are produced in 5 sizes. Designed and built for concealed installations, they have small dimensions, are

More information

Water Source Heat Pump P 34 P 35. Features. Optional. Instruction of model. Water-Cooled Screw Chiller

Water Source Heat Pump P 34 P 35. Features. Optional. Instruction of model. Water-Cooled Screw Chiller Source Heat Pump -Cooled Screw Chiller R410a Product type LSSR10 LSSR14 LSSR16 LSSR20 LSSR28 Rated cooling capacity kw/btu/h 10.5 35836.5 14 47782 15.5 52902 21 71673 28 95564 Rated heating capacity kw/btu/h

More information

Air Cooled Water Chillers. CLS 182 to to 150 kw. Technical Brochure TM CLS-W.3GB Date : October 2004 Supersedes : TM CLS-W.2GB/07.

Air Cooled Water Chillers. CLS 182 to to 150 kw. Technical Brochure TM CLS-W.3GB Date : October 2004 Supersedes : TM CLS-W.2GB/07. Air Cooled Water Chillers CLS 182 to 602 41 to 150 kw Technical Brochure TM CLS-W.3GB Date : October 2004 Supersedes : TM CLS-W.2GB/07.04 R Specifications General characteristics The CLS air cooled water

More information

Vent-Axia Roof Units Range Energy Recovery Ventilation (ERV) Range

Vent-Axia Roof Units Range Energy Recovery Ventilation (ERV) Range CI/SfB (57.7) 1st Edition from Vent-Axia Vent-Axia Roof Units Range Energy Recovery Ventilation (ERV) Range Energy Recovery Ventilation (ERV) Range Building on the success of the Sentinel Totus 2 range

More information

Product Brochure Fan coil units for suspended ceilings HyPower-Geko. Energy efficient Powerful Hygienic Low noise

Product Brochure Fan coil units for suspended ceilings HyPower-Geko. Energy efficient Powerful Hygienic Low noise Product Brochure Fan coil units for suspended ceilings HyPower-Geko Energy efficient Powerful Hygienic Low noise Optimal climate: Hygienic. Efficient. Sustainable. The HyPower-Geko fan coil units generate

More information

BUILDING EFFICIENCY Energy Efficient Variable Speed EC Motor Fan Coil Unit Solutions Model YECFC

BUILDING EFFICIENCY Energy Efficient Variable Speed EC Motor Fan Coil Unit Solutions Model YECFC BUILDING EFFICIENCY Energy Efficient Variable Speed EC Motor Fan Coil Unit Solutions Model YECFC Product Introduction INTRODUCTION Johnson Controls YORK YECFC fan coil units are high efficiency, low profile,

More information

Fan coils with Inverter Brushless motor (EC) Concealed installation

Fan coils with Inverter Brushless motor (EC) Concealed installation FCZI P Fan coils with Inverter Brushless motor (EC) Concealed installation Aermec is participating in the EUROVENT Program : FCH The related products can be found at the website www.eurovent-certification.com

More information

UTA STANDARD. Ductable units. Range. Air handling unit with high available static pressure. NEW Eco-Design Filter. V3000 control Fresh air management

UTA STANDARD. Ductable units. Range. Air handling unit with high available static pressure. NEW Eco-Design Filter. V3000 control Fresh air management Ductable units NEW Eco-Design Filter Air handling unit with high available static pressure V3000 control Fresh air management The range of air handling units is designed for suspended ceiling heating and

More information

Fan coil unit NBS 100/150

Fan coil unit NBS 100/150 Fan coil unit /150 Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telephone +49 (0) 74 63-980 - 0 Fax +49 (0) 74 63-980 - 200 info@schako.de www.schako.de Contents Description...3 Advantages...3

More information

Cassette 4 Ways FCU DC Service manual

Cassette 4 Ways FCU DC Service manual Cassette Ways FCU DC Service manual MUCS-W7 www.mundoclima.com CL022 to CL02 English Two-pipe Four-way Cassette DC Fan Coil Unit 1. External Appearance... 2 2. Features... 2. Product lineup.... Accessories....

More information

Technical Service Manual

Technical Service Manual Technical Service Manual 60 Hz Low/Mid Pressure Duct Units 7 48 MBH Units 96 MBH Unit June 2009 VRF-SVM21A-EN Low and Mid Pressure Duct Units 1. Features......... 2 2. Specifications......... 3 3. Dimensions.........

More information

NEW Acoustic In-Line Fans (ACQ)

NEW Acoustic In-Line Fans (ACQ) NEW Acoustic In-Line Fans (ACQ) Acoustically treated housing, Class O rated, sandwich construction selected for maximum noise absorption Motors protected to IP44 Motor insulation Class B Maximum operating

More information

Air Conditioning Technical Data FXDQ-A3 > FXDQ15A3VEB > FXDQ20A3VEB > FXDQ25A3VEB > FXDQ32A3VEB > FXDQ40A3VEB > FXDQ50A3VEB > FXDQ63A3VEB

Air Conditioning Technical Data FXDQ-A3 > FXDQ15A3VEB > FXDQ20A3VEB > FXDQ25A3VEB > FXDQ32A3VEB > FXDQ40A3VEB > FXDQ50A3VEB > FXDQ63A3VEB Air Conditioning Technical Data FXDQ-A3 > FXDQ15A3VEB > FXDQA3VEB > FXDQ25A3VEB > FXDQ32A3VEB > FXDQ40A3VEB > FXDQ50A3VEB > FXDQ63A3VEB TABLE OF CONTENTS FXDQ-A3 1 Features.............................................................

More information

PRODUCT CATALOGUE CHILLER ECOMAX

PRODUCT CATALOGUE CHILLER ECOMAX PRODUCT CATALOGUE CHILLER ECOMAX English/02-2005 AIR COOLED CHILLER INTRODUCTION TO THE RANGE The simple and robust design of the Ecomax range brings real benefits in terms of savings in investment, operation

More information

indoor air quality and energy saving TECHNICAL DATA HRE-TOP EC VENTILATION UNIT WITH HEAT RECOVERY FOR COMMERCIAL AND INDUSTRIAL BUILDINGS

indoor air quality and energy saving TECHNICAL DATA HRE-TOP EC VENTILATION UNIT WITH HEAT RECOVERY FOR COMMERCIAL AND INDUSTRIAL BUILDINGS indoor air quality and energy saving TECHNICAL DATA HRE-TOP EC VENTILATION UNIT WITH HEAT RECOVERY FOR COMMERCIAL AND INDUSTRIAL BUILDINGS HRE-TOP EC Non-residential ventilator unit ith dual flo and high

More information

Ductable Modular Fan Coil Unit VPX. Technical Brochure TM VPX-W.2GB Date : May 2004 Supersedes : TM VPX-W.1GB/08.03

Ductable Modular Fan Coil Unit VPX. Technical Brochure TM VPX-W.2GB Date : May 2004 Supersedes : TM VPX-W.1GB/08.03 Ductable Modular Fan Coil Unit VPX Technical Brochure TM VPX-W.2GB Date : May 2004 Supersedes : TM VPX-W.1GB/08.03 Design Features Presentation The VPX fan coil unit has been specially designed to meet

More information

LSE kw. Outdoor packaged unit. Air/water chillers and heat pumps LSE PLUS

LSE kw. Outdoor packaged unit. Air/water chillers and heat pumps LSE PLUS Air/water chillers and heat pumps LSE Outdoor packaged unit LSE 60-00 kw Multi-scroll solutions for reliability and high efficiency at partial loads Scroll compressor PLUS R-0A R-0A refrigerant Cooling

More information

TECHNICAL MANUAL ESTRO BLDC ESTRO BLDC FAN COILS - BRUSHLESS TECHNOLOGY. 1.5 kw kw

TECHNICAL MANUAL ESTRO BLDC ESTRO BLDC FAN COILS - BRUSHLESS TECHNOLOGY. 1.5 kw kw GB TECHNICAL MANUAL ESTRO BLDC ESTRO BLDC FAN COILS - BRUSHLESS TECHNOLOGY 1.5 kw - 9.0 kw TABLE OF CONTENTS 1 Generalities... 3 2 Models and constructive components...4-5 3 Accessories available... 6

More information

NFCC Hydronic Terminal. Unit Description. Availale Models

NFCC Hydronic Terminal. Unit Description. Availale Models 202 1003 Professional fan coils Power from 1,4 to 9,7 kw Unit Description Availale Models Hydronic Terminal are the Climaveneta professional fan coils. The low-speed centrifugal fan, with its simple and

More information

Technical Support Division GD CHIGO HEATING & VENTILATION EQUIPMENT CO., LTD.

Technical Support Division GD CHIGO HEATING & VENTILATION EQUIPMENT CO., LTD. Technical Support Division 2012.10 1 1. External appearance 2. Nomenclature 3. Specifications 4. Dimensions 5. Service space 6. Piping diagram 7. Wiring diagram 8. Capacity tables 9. Electric characteristics

More information

CHENGUAN MACHINHEY & FREEZING TECHNOLOGIES

CHENGUAN MACHINHEY & FREEZING TECHNOLOGIES CHENGUAN MACHINHEY & FREEZING TECHNOLOGIES Donguan street, Shangyu City, Zhejiang Prov,China Tel:+86-575-82566722 Mobile:+86-13867501690 www.syfreezer.com E-mail:ring@syfreezer.com Unit Coolers Efficient

More information

Resolair 64 and 68. Comfort air conditioning unit with highly efficient regenerative heat storage packages. AIR VOLUME FLOW: 3,900 23,100 m³/h

Resolair 64 and 68. Comfort air conditioning unit with highly efficient regenerative heat storage packages. AIR VOLUME FLOW: 3,900 23,100 m³/h Comfort air conditioning unit with highly efficient regenerative heat storage packages 68 10 01 - simplified illustration Automatically selects the most economical operating mode! 64 and 68 AIR OLUME FLOW:

More information

CGAM. Air-cooled scroll chiller. Accessories. Customer benefits. Tracer CH530 Control. Main features. Energy saving options.

CGAM. Air-cooled scroll chiller. Accessories. Customer benefits. Tracer CH530 Control. Main features. Energy saving options. CGAM Air-cooled scroll chiller Customer benefits Life cycle effectiveness Efficiency and sound level without compromise All year round operation Extreme reliability and durability Wide application flexibility

More information

Fan Coil Units. Technical Data. Flexi type unit ECDEN FWD-AT/AF

Fan Coil Units. Technical Data. Flexi type unit ECDEN FWD-AT/AF Fan Coil Units Technical Data Flexi type unit ECDEN11-400 Fan Coil Units Technical Data Flexi type unit ECDEN11-400 Table of Contents 3 I Flexi type unit FWD-AT... 3 FWD-AF... 33 1 2 Fan coil Indoor unit

More information

IN-LINE CENTRIFUGAL FANS FOR INDUSTRIAL / COMMERCIAL USE

IN-LINE CENTRIFUGAL FANS FOR INDUSTRIAL / COMMERCIAL USE IN-LINE CENTRIFUGAL FANS FOR INDUSTRIAL / COMMERCIAL USE CIL - Centrifugal In-Line Fans SBAF - Slimbox Acoustic Fans ACF - Acoustic Cabinet Fans - Direct Drive ACFS - Super-Silent Acoustic Cabinet Fans

More information

Hydropac. Waterside Control Fan Coil Units For Horizontal and Vertical Applications. June Hydropac. Features

Hydropac. Waterside Control Fan Coil Units For Horizontal and Vertical Applications. June Hydropac. Features June 2003 Hydropac Hydropac Waterside Control Fan Coil Units For Horizontal and Vertical Applications Features Flush panel extra rigid construction. Low noise levels. Eleven speed transformer. Full acoustic

More information

Technical Catalogue. Cassette Fan Coils Climmy Comfort 3

Technical Catalogue. Cassette Fan Coils Climmy Comfort 3 Technical Catalogue Cassette Fan Coils Climmy Comfort 3 CONTENTS INTRODUCTION Version Fan Coil Page 3 Page 4 Page 6 Page 7 Page 8 Page 12 Page 13 Page 15 Page 16 Page 18 Page 19 Page 20 Page 22 -ECM Version

More information

GENERAL ELECTRIC CONCEALED CHILLED WATER FAN COIL UNITS

GENERAL ELECTRIC CONCEALED CHILLED WATER FAN COIL UNITS GENERAL ELECTRIC CONCEALED CHILLED WATER FAN COIL UNITS ACWL Series ACWL0 thru ACWL4 00 CFM thru 400 CFM GE_ACWL_series.indd 3// : PM CONTENTS Model decoding 3 Unit features 3 Standard specifications 3-4

More information

Accessories. Series REC

Accessories. Series REC Accessories Series REC 5-7-9 ACCESSORIES REC Series RBA BAF RBE CV3 PC3 SRE PSD CSA GIU TPA O. REC 5 REC 5-6 - 5BT11 5BT6 1CO71 1CO73 1SE96 5PR 1KR6 5SU137 5TE1 REC 5-12 5BT12 5BT122 5BT121 1CO71 1CO73

More information

Commercial Blower Coil Air Handlers

Commercial Blower Coil Air Handlers Commercial Blower Coil Air Handlers MODEL : BDH(V)B - 048, 065, 080 7400 CMH - 14300 CMH 30 kw - 125 kw BCXB-PRC001-E4 Contents Model Number Description General Specification Standard Features Unit Configuration

More information

Service manual MIV V4+ Indoor units

Service manual MIV V4+ Indoor units Service manual MIV V4+ Indoor units Floor Standing MVF22A-VA1 MVF28A-VA1 MVF36A-VA1 MV5A-VA1 MVF56A-VA1 MVF71A-VA1 MVF80A-VA1 MVB22A-VA1 MVB28A-VA1 MVB36A-VA1 MVB45A-VA1 MVB56A-VA1 MVB71A-VA1 MVB80A-VA1

More information

Reversible air-to-water heat pump HEAT PUMP HEATING (30/35 C 40/45 C)

Reversible air-to-water heat pump HEAT PUMP HEATING (30/35 C 40/45 C) Simple, reliable efficient heat pump! Equipped with µconnect controller HFC R410A CERTITA CERTIFIED * Cooling capacity: 5 to 16.5 kw Heating capacity: 6 to 19 kw *except 75HT OPTION HEAT PUMP HEATING (30/35

More information

Sapphire Horizontal Waterside Control Fan Coil Units

Sapphire Horizontal Waterside Control Fan Coil Units Sapphire Horizontal Waterside Control Fan Coil Units Introduction The Quartz SAPPHIRE series is a compact, high output fan coil unit capable of meeting exacting heating and cooling requirements whilst

More information

Making refrigeration greener KELVION KME COMMERCIAL AIR COOLER

Making refrigeration greener KELVION KME COMMERCIAL AIR COOLER Making refrigeration greener KELVION KME COMMERCIAL COOLER Kelvion a tribute to Lord Kelvin Lord Kelvin (1824 1907) formulated the laws of thermodynamics 70 branches and sales partners worldwide More

More information

AQWL/AQWH/AQWR 1404 to 2406

AQWL/AQWH/AQWR 1404 to 2406 Chiller AQWL/AQWH/AQWR 1404 to 2406 Air Cooled Water Chillers Only, Heat Pump and Total Heat Recovery Engineering Data Manual 380 to 634 kw 418 to 702 kw Features & Strength Points A more "slim and light"

More information

Modular fan coil unit model PS

Modular fan coil unit model PS Modular fan coil unit model PS Flexible air conditioning system Modular fan coil units For the perfect indoor climate A pleasant indoor environment is largely determined by the room's climate. People often

More information

V33A Standard/High Efficiency 360 Cassette Indoor Models - 60HZ

V33A Standard/High Efficiency 360 Cassette Indoor Models - 60HZ PRODUCT SPECIFICATIONS Low-sound, standard or high efficiency cassette, encased in galvanized steel offers 360 airflow for immediate, equal distribution of wide-range cooling and heating. Cassette has

More information

HRH. High efficiency heat recovery units. from 300 to m³/h >70 % WITH HIGH EFFICIENCY HEAT RECOUPERATOR

HRH. High efficiency heat recovery units. from 300 to m³/h >70 % WITH HIGH EFFICIENCY HEAT RECOUPERATOR 4 Lmf Clima 6 HRH High efficiency heat recovery units WITH HIGH EFFICIENCY HEAT RECOUPERATOR from 3 to 4.3 m³/h The HRH units have been designed for non-residential applications for which a forced and

More information

HPR. Heat recovery units. from 700 to m³/h R410A HIGH EFFICIENCY WITH ENTHALPY EXCHANGER AND BUILT-IN HEAT PUMP SYSTEM

HPR. Heat recovery units. from 700 to m³/h R410A HIGH EFFICIENCY WITH ENTHALPY EXCHANGER AND BUILT-IN HEAT PUMP SYSTEM 1 Lmf Clima 216 FERRARO GROUP HPR Heat recovery units HIGH EFFICIENCY WITH ENTHALPY EXCHANGER AND BUILT-IN HEAT PUMP SYSTEM from 7 to 23. m³/h Supporting structure in extruded aluminium profiles and curtain

More information

FCVC Series VERTICAL FAN COILS

FCVC Series VERTICAL FAN COILS VERTICAL FAN COILS The FCVC is designed for concealed, wall mounted installations with flexible heating/ cooling loads and minimal duct requirements. With a variety of options, such as fiber free insulation,

More information

PHCD-Series. Catalog

PHCD-Series. Catalog PCD-Series Catalog odel: PCD Introduction PCD fan coil unit is designed for a fully concealed ceiling installation. The external static pressure(esp) is up to 75Pa. Owing to its low static and low noise,

More information

High Performance Fan Coils FCHG Genesis Series Horizontal

High Performance Fan Coils FCHG Genesis Series Horizontal Dimensional Data 5 7 /8 (150) D 14 (356) 2 (51) Diverter - Slides Into Discharge Ductwork Optional: Second Drain Pan Connection E Coil Section X Dimensional Data - IP (in.) / SI [mm] Unit Fan Outlet Duct

More information

INDEX. The technical and dimensional data reported in this manual may be modified in view of any product improvement.

INDEX. The technical and dimensional data reported in this manual may be modified in view of any product improvement. Ceiling-mounted fan heaters TECHNICAL MANUAL GB INDEX 1 MAIN FEATURES... 2 2 RATED TECHNICAL DATA... 3 3 HEATING CAPACITIES... 4 3.1 Heating capacity with water operation... - 11 4 STEAM OPERATION... 12

More information

something new in the air Technical Bulletin

something new in the air Technical Bulletin something new in the air Technical Bulletin 2 Air Leaf 2 Air Leaf 3 Innova is a company operating in the renewable energy sector and develops advanced climatic comfort systems for every season. The technological

More information

Horizontal Series Fan Coil Technical Catalog

Horizontal Series Fan Coil Technical Catalog Horizontal Series Fan Coil Technical Catalog HCY Horizontal Hideaway 200 CFM to 200 CFM The Horizontal Hideaway (HCY) fan coil unit is designed specifically to meet the many varied requirements for a ceiling

More information