CMTE. Tangential Fan Coil Series with Electronic Controlled Motor

Size: px
Start display at page:

Download "CMTE. Tangential Fan Coil Series with Electronic Controlled Motor"

Transcription

1 Tangential Fan Coil Series with Electronic Controlled Motor Designed by Very Low Electric Energy Consumption High Efficiency Extremely Low Noise Level Infra Red Remote Control Step-less Fan Speed Control Engineering Germany Issued 1/ 2011 Update 1/ 2013

2 It is the most comprehensive range, perfect to meet all air-conditioning requirements of work environments like offices, shops, restaurants and hotel rooms where a very quiet operation is re General Description In line with innovative trends and modern industrial design, the fan coil range meets today's demanding requirements of high performance, size, low acoustics, very low energy consumption, ease of installation and maintenance. The fan coil unit has been designed around a platform of models, versions and accessories. All fan coils with tangential fans are equipped with controlled version with tangential fan Range includes stepless flow rates (from 90 to 1300 m3/h), each equipped with 3 row coil and with the possibility to add a 1 row coil for 4 pipe systems. Construction Casing Made from galvanized and pre-painted steel casing with closed cell insulation. The plastic top grid has fixed louvers and is reversible to distribute the air in 2 directions. Standard colours are: - Lateral corners and grid in Pantone 427C (light grey. - Frontal sheet RAL 9003 (White) - Other colours are against request motors which reduce strong the electrical consumption comparative to previous models, with stepless motor speed as standard offering Filter Polypropylene cellular fabric regenerating filter. The filter frame of galvanized steel is inserted into special plastic sliding guides fastened to the internal structure for easy insertion and removal of the filter. Fan assembly greater flexibility in the selection of products. A full range of control options is available including the wireless control offering greater flexibility in the installation of units, with the The low-noise tangential fan assembly is composed of 2 fan shrouds: an external one with an evolving plastic section; internal one of holed, shaped steel. The fan has an external diameter of 120 mm and is the length of the coil. The fins are concave and are positioned in a special shape along the whole length of the fan.

3 Electric motor Three phase permanent magnet brushless motor that is controlled with current reconstructed according to a alternating current sinusoidal wave. The inverter board that controls the motor operation is powered by 230 Volt, single-phase and with a switching system, it generates a 3 phase frequency modulated wave from power supply. Characteristically saving curve of Electric Energy Heat Exchanger It is manufactured from drawn copper tube and the aluminium fins are mechanically bonded onto the tube by an expansion process. The coil has two 1/2 inch BSP internal connections and 1/8 inch BSP air vent and drain. The coil is not suitable for use in corrosive atmosphere or in environments where aluminium may be subject to corrosion. The connections are on the left hand side looking from the air outlet of the unit (see picture). On request or on site the connections can be moved to the other side. Condensate collection tray Made from plastic with an "L"-shape fitted on the inner casing. The outside diameter of the condensate discharge pipe is 15mm. The electric power supply required for the machine is therefore single-phase with voltage of V and frequency of 50-60Hz. Condensate pump (optional) The motor is fitted on sealed for life bearings and is secured on anti-vibration and selflubricating mountings. Internal thermal protection with automatic reset, protection IP 20, class B. Accessories and Controls See pages

4 General Technical Data General Technical Data 1 Coil 3 rows 2-pipe version Fan Speed Inverter Power Air Flow Cooling Total *1 Sensible Cooling Model step Volt m³/h kw kw kpa kw kpa W db/a db/a Δp Cooling Heating *2 Δp Heating Fan Sound Power LW Sound Pressure Lp 1.3-2T 2.3-2T 3.3-2T 5.3-2T 7.3-2T min ,7 0,5 1,0 0,9 0,3 4, max ,1 0,8 2,3 2,0 0, min ,1 0,7 3,5 1,2 0,7 5, max ,9 1,3 9,1 2,7 2, min ,5 1,1 6,2 1,8 3, max ,8 1,9 18,4 4,2 10, min ,7 1,3 4,7 2,5 10,3 7, max ,4 2,6 14,5 6,2 25, min ,0 2,0 14,0 3,1 7, max ,9 3,4 34,2 8,1 24, Coils 4-pipe version add. 1 row coil Fan Speed Inverter Power Air Flow Cooling Total *1 Sensible Cooling Model step Volt m³/h kw kw kpa kw kpa W db/a db/a Δp Cooling Heating *2 Δp Heating Fan Sound Power LW Sound Pressure Lp 1.3-4T 2.3-4T 3.3-4T 5.3-4T 7.3-4T min ,7 0,5 1,0 0,2 3,5 4, max ,1 0,9 2,3 0,8 7, min ,1 0,7 3,5 0,4 7,7 5, max ,9 1,3 9,1 1,2 19, min ,5 1,1 6,2 0,9 2, max ,8 1,9 18,4 1,9 6, min ,7 1,3 4,7 1,1 2,5 8, max ,4 2,6 14,5 2,8 9, min ,0 2,0 14,0 1,3 16, max ,9 3,4 34,3 3,6 38, *1 Water temperature 7/12 C / Air Entering Temperature + 27 C d.b C w.b. *2 Water temperature +50/40 C / Air Entering Temperature + 20 C

5 Water Pressure drop p kpa 3 - row coil The water drop figures refer to a mean water temperature of 10 C; for different temperatures multiply the pressure drop figures by the correction factors K C K 0,94 0,90 0,86 0,82 0,78 0,74 0,7 Water Flow l/h p kpa 1 row additional coil The water pressure drop figures refer to a mean water temperature of 65 C; For different temperatures multiply the pressure drop figures by the correction factors K C K 1,14 1,08 1,02 0,96 0,9 Water Flow l/h

6 Valve Kits Main Coil 3-way valve Control valve kit: 3-way vlave, on-off, with electric motor and mounting kit with micrometric lockshield valve Model Dimension (mm) Valve Micrometric lockshield valve Code A B C D E DN Ø Kvs DN Ø Kvs fitted not fitted ½ F 1,6 15 ½ F 2 VL 331 VL ¾ F 2,5 15 ½ F 2 VL 332 VL 322 Additional Coil 3 way valve Control valve kit: 3-way valve, on-off with electric motor and mounting kit with micrometric lockshield valve Model Dimension (mm) Valve Micrometric lockshield valve Code A B C D DN Ø Kvs DN Ø Kvs fitted Not fitted ½ 1,6 15 ½ F 2 VL 335 VL 325

7 Valve kits Simplified kit for 3-way valve (NC concealed Models only) 3-way valve, on-off with electric motor and mounting kit. Valve with flat connection without micrometric lockshield valve. Model Dimension (mm) Code Valve Main Valve Additional Valve Main Valve Additional Valve C A1 A2 B1 B2 DN Ø Kvs fitted not fitted fitted not fitted ½ 1,7 VL 311 VL 301 VL 315 VL ¾ 2,8 VL 312 VL 302 VL 315 VL way valve for main and additional coil Control valve kit: 2-way valve, on-off, with electric motor and mounting kit. CODE Model Dimension (mm) Valve Main Valve Additional Valve A C D E H DN Ø Kvs fitted not fitted fitted not fitted ½ 1,7 VL 211 VL 201 VL 211 VL ¾ 2,8 VL 212 VL 202 VL 211 VL 201

8 Accessories CTH Condensate Collection tray Plastic Condensate Drain Pipe PCP for CH, CBV and NC units, HORIZONTAL mounted only Connection Plastic condensate drain pipe with fast connection Type Code side Left CTH-L PCP Code Right CTH-R CTV Condensate Collection tray Feet kit FK Type L (mm) Code for CV / CVB and NC units VERTICAL mounted only CTV Code FK FK FK FK FK for CV units (VERTICAL mounted only) RCH Bottom closing panel Rear closing panel RCV Type Code Type Code 1 RCH RCV RCH RCV RCH RCV RCH RCV RCH RCV HORIZONTAL mounted units VERTICAL mounted units GI Aluminium low intake grid for CV - Model (to be installed with Feet Kit) Front Intake kit Bottom closing panel and Filter sliding guided IF Type Code Type Code 1 GI IF GI IF GI IF GI IF GI IF

9 Accessories Sraight Inlet Flange SIF Type A B C D G Code 1 SIF SIF SIF , SIF SIF , Air Inlet Grid GB Type Dimension B H Code 1 GB x GB x GB x GB x to be connected with the Straight Inlet Flange 7 GB x Straight Outlet Flange SOF Type A B C D 1 SOF SOF SOF , SOF Made of galvanized steel 7 SOF ,5 152 Code Air Outlet Grid OG Double louvre grid to be fitted to the duct, to the straight outlet flange or to the 90 outlet flange Type B Code 1 OG OG OG OG OG Made of anodized aluminium

Carisma The Ultra Quiet Fan Coil

Carisma The Ultra Quiet Fan Coil Carisma The Ultra Quiet Fan Coil Air Conditioning Carisma / CRR Fan Coil Units Quality management systems SO 900 Cert. n 0545/4 www.euroventcertification.com www.certiflash.com CONTENTS Construction ()

More information

NEW. Wall controls. YFCN Fan Coil Units. Technical Guide - for internal distribution only

NEW. Wall controls. YFCN Fan Coil Units.     Technical Guide - for internal distribution only NEW Wall controls Fan Coil Units www.euroventcertification.com www.certiflash.com Technical Guide for internal distribution only CONTENTS Construction Page 4 s Page 5 Dimension, Weight, Water content Page

More information

Cert. n 0545 Carisma CRC Fan Coil Unit The Ultra Quiet Fan Coil TECHNICAL GUIDE

Cert. n 0545 Carisma CRC Fan Coil Unit The Ultra Quiet Fan Coil TECHNICAL GUIDE Cert. n 0545 www.euroventcertification.com Carisma Fan Coil Unit The Ultra Quiet Fan Coil TECHNCAL GUDE Carisma CONTENTS Construction Page 4 s Page 5 Dimension, Weight, Water content Page 6 EUROENT certification

More information

EURUS / EURUS-I. Conditioning your ambient, maximising your comfort.

EURUS / EURUS-I. Conditioning your ambient, maximising your comfort. EURUS / EURUS-I Centrifugal fan coils for surface mounting or recessed installation. Cooling capacities from 0,6 to 7,6 and heating capacity from 0,8 to 9. Air folw from 0 to 0 m /h. Conditioning your

More information

Carisma CRC. Range includes 9 air rates (from 105 to 1500 m 3 /h) It is the most comprehensive range, perfectly suited to meet

Carisma CRC. Range includes 9 air rates (from 105 to 1500 m 3 /h) It is the most comprehensive range, perfectly suited to meet Carisma CRC Fan Coil Unit with Centrifugal Fan with synchronous Motor Range includes 9 air rates (from to 1500 m /h) and 5 models (for wall and ceiling installation, with casing and concealed), each equipped

More information

Technical Catalogue. Cassette Fan Coils Climmy Comfort 3

Technical Catalogue. Cassette Fan Coils Climmy Comfort 3 Technical Catalogue Cassette Fan Coils Climmy Comfort 3 CONTENTS INTRODUCTION Version Fan Coil Page 3 Page 4 Page 6 Page 7 Page 8 Page 12 Page 13 Page 15 Page 16 Page 18 Page 19 Page 20 Page 22 -ECM Version

More information

CENTRIFUGAL FAN COIL UNIT VCE

CENTRIFUGAL FAN COIL UNIT VCE CENTRIFUGAL FAN COIL UNIT VCE 0,51 kw 11,00 kw 0,85 kw 23,75 kw 129 m 3 /h 2003 m 3 /h VCE DESIGN QUALITY COMFORTRELIABILITY 3VERSION12 SIZE DESIGN VCEx0 vertical with cabinet Air intake: bottom vertical

More information

Chiller, Close control and Water terminals. Air Conditioning. Light Commercial, Commercial and Industrial

Chiller, Close control and Water terminals. Air Conditioning. Light Commercial, Commercial and Industrial Chiller, Close control and Water terminals Air Conditioning Light Commercial, Commercial and Industrial Water Terminals 133 Water Terminals Fan coils & Cassette Centrifugal fan-coil SYSCOIL Ductable fan-coil

More information

Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Water terminals SYSCOIL. Centrifugal fan coil units

Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Water terminals SYSCOIL. Centrifugal fan coil units Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Water terminals SYSCOIL Centrifugal fan coil units SYSCOIL Fan coil units Compact, slim fan coil units. Available

More information

Guide Specifications. General. Casing. Coil/Drain pan. Fan/Motor

Guide Specifications. General. Casing. Coil/Drain pan. Fan/Motor Guide Specifications General CR-A series ducted concealed chilled water fan coil units have an air flow range from 45 to 3060 cubic meters per hour with a capacity range from kw up to 9 kw. The CR-A series

More information

Maestro. High Pressure Fan Coil Unit with Asynchronous Motor

Maestro. High Pressure Fan Coil Unit with Asynchronous Motor Maestro High Pressure Fan Coil Unit with Asynchronous Motor The Maestro high pressure fan coils are produced in 5 sizes. Designed and built for concealed installations, they have small dimensions, are

More information

1 AIR HANDLING UNIT TYPE AIR ACCESS 75

1 AIR HANDLING UNIT TYPE AIR ACCESS 75 SUPPLY 1 AIR HANDLING UNIT TYPE AIR ACCESS 75 Location : EXTERNAL Position : SIDE BY SIDE SLIDING PANELS for COMPLETE ACCESSIBILITY MULTI SERVICE BULKHEAD for HYDRAULIC AND ELECTRICAL CONNECTIONS Self-supporting

More information

Fan coil units MAJOR 2 CV/CH

Fan coil units MAJOR 2 CV/CH CH 41 D CV 1 D MAJOR 2: Design and performance HEE impeller for increased performance Motor optional MAJOR 2 is a non-independant chilled and/or hot water supplied air conditioning Comfort unit for the

More information

Chiller. AQL/AQH 40 to 75. Air Cooled Water Chillers Cooling Only and Heat Pump Engineering Data Manual to 77.2 kw to 75.

Chiller. AQL/AQH 40 to 75. Air Cooled Water Chillers Cooling Only and Heat Pump Engineering Data Manual to 77.2 kw to 75. Chiller AQL/ to 75 Air Cooled Water Chillers Only and Heat Pump Engineering Data Manual.0 to 75.8 kw 39.9 to 77.2 kw Outstanding Strength Points R410A Refrigerant. New simpler refrigerant circuit layout.

More information

TECHNICAL MANUAL ESTRO BLDC ESTRO BLDC FAN COILS - BRUSHLESS TECHNOLOGY. 1.5 kw kw

TECHNICAL MANUAL ESTRO BLDC ESTRO BLDC FAN COILS - BRUSHLESS TECHNOLOGY. 1.5 kw kw GB TECHNICAL MANUAL ESTRO BLDC ESTRO BLDC FAN COILS - BRUSHLESS TECHNOLOGY 1.5 kw - 9.0 kw TABLE OF CONTENTS 1 Generalities... 3 2 Models and constructive components...4-5 3 Accessories available... 6

More information

Ductable Modular Fan Coil Unit VPX. Technical Brochure TM VPX-W.2GB Date : May 2004 Supersedes : TM VPX-W.1GB/08.03

Ductable Modular Fan Coil Unit VPX. Technical Brochure TM VPX-W.2GB Date : May 2004 Supersedes : TM VPX-W.1GB/08.03 Ductable Modular Fan Coil Unit VPX Technical Brochure TM VPX-W.2GB Date : May 2004 Supersedes : TM VPX-W.1GB/08.03 Design Features Presentation The VPX fan coil unit has been specially designed to meet

More information

ERP 2015 Regulation (EU) Compliant with. No. 327/2011. Cert. n Heating. Meltemi Door Curtains

ERP 2015 Regulation (EU) Compliant with. No. 327/2011. Cert. n Heating. Meltemi Door Curtains Compliant with ERP 015 Regulation (EU) No. 7/011 Cert. n 0545 Heating Door Curtains The range of SBIN door curtains offers imum flexibility in the protection of doors and open access compartments. By connecting

More information

MAJOR 2 NCH. Ductable units. High pressure and high capacity ductable units RANGE NCH Y NCH NCH I COADIS COMBI. Motor optional

MAJOR 2 NCH. Ductable units. High pressure and high capacity ductable units RANGE NCH Y NCH NCH I COADIS COMBI. Motor optional Y + U I COADIS COMBI High pressure and high ductable units Motor optional is a non independent air conditioning terminal unit for heating and cooling offices and hotels. With reduced dimensions and designed

More information

The World Leading Air-conditioning Company

The World Leading Air-conditioning Company The World Leading Air-conditioning Company Table of Contents DESCRIPTIONS Model Number Nomenclature Features & Benefits Physical Dimension Fan Performance Curve (4 Row) - 40LMA024 with AC Motor - 40LMA040

More information

Residential comfort unit OperatiOn 2 models. new builds or existing properties. 5 operating modes COnfOrmity COmpOnents

Residential comfort unit OperatiOn 2 models. new builds or existing properties. 5 operating modes COnfOrmity COmpOnents Residential HEE motor Silent operation Heating capacity: 200 W to 4 kw Cooling capacity: 100 W to 3 kw Operation is CIAT's residential. This vertical cased unit, designed for heating and cooling, is available

More information

Chiller Close Control Water terminals SYSCASSETTE. Water cassette units

Chiller Close Control Water terminals SYSCASSETTE. Water cassette units Chiller Close Control Water terminals SYSCASSETTE Water cassette units SYSCASSETTE Water cassette Available accessories Available in 8 different sizes and 2 versions. Due to its square design these units

More information

Air Cooled Water Chillers. CLS 182 to to 150 kw. Technical Brochure TM CLS-W.3GB Date : October 2004 Supersedes : TM CLS-W.2GB/07.

Air Cooled Water Chillers. CLS 182 to to 150 kw. Technical Brochure TM CLS-W.3GB Date : October 2004 Supersedes : TM CLS-W.2GB/07. Air Cooled Water Chillers CLS 182 to 602 41 to 150 kw Technical Brochure TM CLS-W.3GB Date : October 2004 Supersedes : TM CLS-W.2GB/07.04 R Specifications General characteristics The CLS air cooled water

More information

Engineering Data Manual. New : available with EC motor. High Static Pressure Ductable Fan Coil Unit. Models 07 to to 4650 m 3 /h

Engineering Data Manual. New : available with EC motor. High Static Pressure Ductable Fan Coil Unit. Models 07 to to 4650 m 3 /h Engineering Data Manual New : available with EC motor VH High Static Pressure Ductable Fan Coil Unit Models 07 to 27 800 to 4650 m 3 /h General Characteristics Presentation On model VH 07, coils have 4

More information

Compresseur scroll. Refrigerant R410A SYSAQUAC. Air Cooled Condensing Units Models 25 to to 136.0kW

Compresseur scroll. Refrigerant R410A SYSAQUAC. Air Cooled Condensing Units Models 25 to to 136.0kW Compresseur scroll Refrigerant R410A SYSAQUAC Air Cooled Condensing Units Models 25 to 125 32.0 to 136.0kW SYSAQUA Condensation 1 Key Points R410A refrigerant, Units are optimized for partial load operation,

More information

R410A TECHNICAL MANUAL. Inverter Single Split Series Air Conditioner. FTK-J, FTXN-J Series. Cooling only & Heatpump [50Hz] TM-5WMY-J-ST-A2

R410A TECHNICAL MANUAL. Inverter Single Split Series Air Conditioner. FTK-J, FTXN-J Series. Cooling only & Heatpump [50Hz] TM-5WMY-J-ST-A2 R410A TECHNICAL MANUAL Inverter Single Split Series Air Conditioner FTK-J, FTXN-J Series Cooling only & Heatpump [50Hz] TM-5WMY-J-ST-A2 Table of Contents Table of Contents Nomenclature...1 Indoor...1 Outdoor...1

More information

Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE C 30 C 35 C 40 C 45 C LWB C. Sens Cap KW

Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE C 30 C 35 C 40 C 45 C LWB C. Sens Cap KW R410a Refrigerant SHS1 Split Ducted Model INDOOR COIL ENTERING AIR TEMP DB WB 21 23 2 27 29 31 Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE 30 3 40 4 17 14.0 9.1 9.8 13.2 8.8 9.0 12. 8. 12.9

More information

NEW. Wall controls. SkyStar SkyStar ECM Cassette Fan Coil Units. Air Conditioning. Cert. n 0545

NEW. Wall controls. SkyStar SkyStar ECM Cassette Fan Coil Units. Air Conditioning.  Cert. n 0545 NEW Wall controls Cert. n 04 www.eurovent-certification.com Air Conditioning ECM Cassette Fan Coil Units CONTENTS Introduction Page 3 Main components Page 4 EUROVENT Certifications Page s Page 6 side pressure

More information

Total cooling capacity kw Total heating capacity kw Features

Total cooling capacity kw Total heating capacity kw Features Room Fan Coils Idrofan Quality Management Systems 42N Total cooling capacity 0.75-6.35 kw Total heating capacity 0.60-9.50 kw The new generation 42N_S product range combines aesthetic and attractive design

More information

Concealed Ducted Split Series R22

Concealed Ducted Split Series R22 Concealed Ducted Split Series R22 24-60 MBH Ducted Split with Hermetic Compressor Tropical 50 Hz For more technical information please visit Table of Contents INTRODUCTION 2 NOMENCLATURE 2 UNIT RATING

More information

VLH 504 to Air-to-Water Reverse Cycle Heat Pumps. 126 to 294 kw. 133 to 307 kw

VLH 504 to Air-to-Water Reverse Cycle Heat Pumps. 126 to 294 kw. 133 to 307 kw Air-to-Water Reverse Cycle Heat Pumps VLH 504 to 1204 126 to 294 kw 133 to 307 kw Technical Brochure TM VLH-N.3GB Date : June 2005 Supersedes : TM VLH-N.2GB/07.04 Specifications Advantages Range extension

More information

The Clima Canal is quiet even at high outputs, making it a discreet and effective heater for almost any situation

The Clima Canal is quiet even at high outputs, making it a discreet and effective heater for almost any situation The is quiet even at high outputs, making it a discreet and effective heater for almost any situation A selection of grilles and finishes are available. Installation is simple and hassle-free due to the

More information

SysCoil 2. Fan Coil Units Models SVC, SVN, SHC, SHN to 8.75kW to 4.90kW. 94 to /h

SysCoil 2. Fan Coil Units Models SVC, SVN, SHC, SHN to 8.75kW to 4.90kW. 94 to /h SysCoil Fan Coil Units Models SVC, SVN, SHC, SHN 0.79 to 8.75kW 0.49 to 4.90kW 94 to 930 3 /h SysCoil Quality, efficiency and reliability Vertical console units with cabinet, SVC type SVC vertical console

More information

SLH 1202 to Air-to-Water Reverse Cycle Heat Pumps. With Screw Compressors. 261 to 775 kw. 287 to 853 kw

SLH 1202 to Air-to-Water Reverse Cycle Heat Pumps. With Screw Compressors. 261 to 775 kw. 287 to 853 kw Air-to-Water Reverse Cycle Heat Pumps SLH 1202 to 3804 With Screw Compressors 261 to 775 kw 287 to 853 kw Technical Brochure TM SLH-A.2GB Date : November 2004 Supersedes : TM SLH-A.1GB/05.04 Design Features

More information

Address: VTS Clima L.L.C.

Address: VTS Clima L.L.C. Address: VTS Clima L.L.C. Business Bay, Churchill Tower, Office 2409, P.O.Box#76849 Dubai, UAE phone: +971 (4) 443 91 20 fax: +971 (4) 443 96 20 e-mail: dubai@vtsgroup.com www.uae.vtsgroup.com Index VTS

More information

PH120. Rooftop Packaged. R410a Refrigerant PERFORMANCE DATA OUTDOOR COIL ENTERING TEMPERATURE 0 C

PH120. Rooftop Packaged. R410a Refrigerant PERFORMANCE DATA OUTDOOR COIL ENTERING TEMPERATURE 0 C PH120 R410a Refrigerant Rooftop Packaged INDOOR COIL ENTERING AIR TEMP 0 c DB WB 21 23 25 27 29 31 PERFORMANCE DATA OUTDOOR COIL ENTERING TEMPERATURE 0 C 30 35 40 45 Cap Cap Cap Cap 17 115.3 70.7 11.5

More information

42CET/ 42CED Series Chilled Water Fan Coil Unit Furred-in Ceiling Model 300 to 1400 cfm Electric heater option

42CET/ 42CED Series Chilled Water Fan Coil Unit Furred-in Ceiling Model 300 to 1400 cfm Electric heater option 42CET/ 42CED Series Chilled Water Fan Coil Unit Furred-in Ceiling Model 0 to 10 cfm Electric heater option 42DC/ 42DCD Series Chilled Water Fan Coil Unit Furred-in Ceiling Model 0 to 00 cfm Electric heater

More information

Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE C 30 C 35 C 40 C 45 C LWB C. Sens Cap KW

Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE C 30 C 35 C 40 C 45 C LWB C. Sens Cap KW R410a Refrigerant SHS25 Split Ducted Model INDOOR COIL ENTERING AIR TEMP DB WB 21 2 25 27 29 1 Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE 0 5 40 45 17 2.4 1.8 11. 22.2 1.4 11.9 21.1 12.9 12.2

More information

SPLIT DUCTED UNIT SCA300C / SCA300E TECHNICAL SELECTION DATA SPECIFICATION SUMMARY UNIT FEATURES CONTROL OPTIONS UNIT COMPLIANCE

SPLIT DUCTED UNIT SCA300C / SCA300E TECHNICAL SELECTION DATA SPECIFICATION SUMMARY UNIT FEATURES CONTROL OPTIONS UNIT COMPLIANCE TECHNICAL SELECTION DATA SPLIT DUCTED UNIT 3 THREE PHASE SCROLL TWO STAGE CENTRIFUGAL LOUVRE AXIAL UNIT FEATURES Scroll Compressor Multiple Speed Outdoor Fans Louvred Outdoor Coil Guard Pre-charged with

More information

LOW STATIC FAN COIL UNITS District Cooling Chilled Water Application

LOW STATIC FAN COIL UNITS District Cooling Chilled Water Application STATIC FAN COIL UNITS District Cooling Chilled Water Application CLASSIFIED INSULATION & FILTER MEDIA GFC LD Series Cooling Capacity Range 9,690 yo 46,064 BTU/HR (4 ROWS ) GFC-LD-TC-10-13 3 General Specifications

More information

Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE C 30 C 35 C 40 C 45 C LWB C. Sens Cap KW

Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE C 30 C 35 C 40 C 45 C LWB C. Sens Cap KW R410a Refrigerant SHS35 Split Ducted Model INDOOR COIL ENTERING AIR TEMP DB WB 21 23 25 27 29 31 Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE 30 35 40 45 17 34.1 21.1 11.4 32.5 20.4 11.7 30.8

More information

FCVC Series VERTICAL FAN COILS

FCVC Series VERTICAL FAN COILS VERTICAL FAN COILS The FCVC is designed for concealed, wall mounted installations with flexible heating/ cooling loads and minimal duct requirements. With a variety of options, such as fiber free insulation,

More information

Driving and Connecting Globally. Fan Coil Unit. Model : PHW-K Size : 510CMH~2720CMH. Made in Taiwan

Driving and Connecting Globally. Fan Coil Unit. Model : PHW-K Size : 510CMH~2720CMH. Made in Taiwan Driving and Connecting Globally Fan Coil Unit : PHW-K Size : 510CMH~2720CMH Made in Taiwan Features Superior low-height design. Stainless steel drain pan for condensate and corrosion protection. Flexibe-reverse

More information

Ceiling Concealed Series FDMRN-AV1K. 50Hz. Preliminary

Ceiling Concealed Series FDMRN-AV1K. 50Hz. Preliminary Ceiling Concealed Series FDMRN-AV1K 50Hz Nomenclature Main Benefits Engineering and Physical Data Electrical Data Capacity Tables Outline and Dimensions Electrical Connection Refrigerant Piping Nomenclature

More information

Air-Cooled Liquid Chiller with integrated hydraulic module

Air-Cooled Liquid Chiller with integrated hydraulic module Air-Cooled Liquid Chiller with integrated hydraulic module Cooling only: CGAN 200-250 - 300-400 - 450-490 - 500-600 - 700-800 - 900-925 Reversible: CXAN 200-250 - 300-400 - 450-490 - 500-600 - 700-800

More information

BRIZA 22 HYBRID HEATING & COOLING

BRIZA 22 HYBRID HEATING & COOLING BRIZA 22 HYBRID HEATING & COOLING Built-in Ceiling: BABC/BT BABC/FT Built-in Wall: BABW/BT BABW/BF BABW/FT BABW/FF INFO SHEET BRIZA 22 HYBRID, COMPACT FANCOIL With EC Greentech EBM-PAPST technology Europe

More information

Product Data. Features/Benefits. 42BH System Fan Coil. 800 to 4000 Cfm

Product Data. Features/Benefits. 42BH System Fan Coil. 800 to 4000 Cfm Product Data 42BH System Fan Coil 800 to 4000 Cfm Satisfy All Your Design Requirements with Carrier s Versatile 42BH Fan Coil Unit A selection of 6 sizes covers capacities from 800 to 4000 cfm Choice of

More information

Innovative, High Performance, Quiet Units.

Innovative, High Performance, Quiet Units. Fan Coil Units Innovative, High Performance, Quiet Units. Technical Brochure TM AQF-A.4GB Date : January 2006 Supersedes : TM AQF-A.3GB/04.04 Quality, efficiency and reliability, built into every unit...

More information

PACKAGE UNIT PCA340U TECHNICAL SELECTION DATA. -10 o C UNIT FEATURES SPECIFICATION SUMMARY UNIT OPTIONS CONTROL OPTIONS UNIT COMPLIANCE.

PACKAGE UNIT PCA340U TECHNICAL SELECTION DATA. -10 o C UNIT FEATURES SPECIFICATION SUMMARY UNIT OPTIONS CONTROL OPTIONS UNIT COMPLIANCE. TECHNICAL SELECTION DATA PACKAGE UNIT + o C -10 o C 3 THREE PHASE SCROLL TWO STAGE CENTRIFUGAL LOUVRE LIANT SCROLL RESSOR AXIAL UNIT FEATURES SPECIFICATION SUMMARY Scroll Compressor Multiple Speed Outdoor

More information

ACOUSTIC CABINET FANS CVB / CVT Series

ACOUSTIC CABINET FANS CVB / CVT Series Cabinet fans manufactured from heavy gauge galvanised steel sheet and internally lined with melamine foam flame retardant acoustic insulation (M1). All models incorporate double inlet single phase direct-drive

More information

Product Catalogue ARMONIA Providing indoor climate comfort

Product Catalogue ARMONIA Providing indoor climate comfort Product Catalogue ARMONIA Providing indoor climate comfort ARMONIA 1,3-11 kw Water cassette Main applications Light commercial buildings Offi ces Shops General description Why this choice? Silent operation

More information

BRIZA EC 12 HYBRID. World s slimmest fan coil HEATING AND COOLING

BRIZA EC 12 HYBRID. World s slimmest fan coil HEATING AND COOLING World s slimmest fan coil wall and ceiling installation 2-or 4-Pipe system heating and / or cooling with or without enclosure easy installation 24VDC EC motor silent, powerful, economical, sustainable

More information

Fan Coil Units. Technical Data ECDEN FWL-DT/DF

Fan Coil Units. Technical Data ECDEN FWL-DT/DF Fan Coil Units Technical Data ECDEN10-400 FWL-DT/DF Fan Coil Units Technical Data ECDEN10-400 FWL-DT/DF TABLE OF CONTENTS FWL-DT/DF 1 Features.............................................................

More information

BACKWARD CURVE CENTRIFUGAL FANS KABB / KABT Series

BACKWARD CURVE CENTRIFUGAL FANS KABB / KABT Series Cabinet fans manufactured from galvanised steel sheet with double thickness side panels lined with 17 mm thickness of fireproof fibreglass acoustic insulation (M0). Circular duct connection flange on the

More information

Midea Air Handling Unit

Midea Air Handling Unit Midea Air Handling Unit Floor mounted 3000CFM ---25000CFM Vertical mounted 3000CFM ---25000CFM Ceiling suspended 1000CFM ---9000CFM Midea reserves the right to improve the product and technology without

More information

something new in the air Technical Bulletin

something new in the air Technical Bulletin something new in the air Technical Bulletin 2 Air Leaf 2 Air Leaf 3 Innova is a company operating in the renewable energy sector and develops advanced climatic comfort systems for every season. The technological

More information

BASTONE (dual) fancoil Units

BASTONE (dual) fancoil Units BASTONE (dual) fancoil Units Technical information manual Western Airconditioning B.V. Tel. +31 (0) 33 247 78 00 www.western.nl 1-INTRODUCTION..3 2- WORKING CONDITION LIMITS...3 3- COANDA EFFECT 3 4- KEY

More information

HBC SERIES-PSC MOTOR HBCX SERIES-ECM MOTOR

HBC SERIES-PSC MOTOR HBCX SERIES-ECM MOTOR PRODUCT SPECIFICATIONS *HBC(X) *PHBC(X) *RHBC(X) *CHBC(X) Chilled Water/Hot Water 2-pipe/4-Pipe HBC SERIES- HBCX SERIES-ECM MOTOR Ceiling Concealed Horizontal -1 CFM Ceiling Concealed Ceiling Recessed

More information

WATER SOURCE HEAT PUMPS

WATER SOURCE HEAT PUMPS HIGH-EFFICIENCY WATER SOURCE HEAT PUMPS AND WATER COOLED AIR CONDITIONERS HORIZONTAL & VERTICAL MODELS 1/2-5 TONS GENERAL All Models 1 2-5 tons ship as factory-charged packages. Horizontal (HWP) units

More information

DAIKIN INDUSTRIES, LTD. Ceiling Concealed Chilled Water Fan Coil Unit (50Hz/60Hz)

DAIKIN INDUSTRIES, LTD. Ceiling Concealed Chilled Water Fan Coil Unit (50Hz/60Hz) Engineering Data ED-FWW-201501 Ceiling Concealed Chilled Water Fan Coil Unit (50Hz/60Hz) Models: FWW200 FWW300 FWW400 FWW600 FWW800 FWW1000 FWW1200 FWW1400 FWW1600 FWW1800 Air Flow: 360-3020m 3 /h DAIKIN

More information

Water terminals From 360 to 1598 m 3 /h. From 1.3 to 9.6 kw. SysQuare. Chilled water cassettes. From 1.1 to 14.0 kw

Water terminals From 360 to 1598 m 3 /h. From 1.3 to 9.6 kw. SysQuare. Chilled water cassettes. From 1.1 to 14.0 kw Water terminals From 360 to 1598 m 3 /h SysQuare Chilled water cassettes From 1.3 to 9.6 kw From 1.1 to 14.0 kw SysQuare The best way to combine low noise and energy savings 6 sizes (20, 30, 40, 50, 60

More information

FCX TECHNICAL BOOKLET

FCX TECHNICAL BOOKLET FAN COIL FCX US FCX USPO This document is based on AERMEC s FCX US, USP, USPO Technical and Installa on Booklet but reflects only those sizes and configura ons currently offered by Phoenix Energy Supply.

More information

CHILLED WATER FAN-COIL UNITS

CHILLED WATER FAN-COIL UNITS 40LM - PRODUCT DATA DIGEST CHILLED WATER FAN-COIL UNITS QUALITY SYSTEM MALAYSIA MS ISO 001 REG. NO: AR 023 1 Any room, every room flexibility in an air conditioning system FEATURES: Chilled Water Furred-in

More information

42N. Room Fan Coils PRODUCT SELECTION DATA. MAINTENANCE INSTRUCTIONS Simpified installation & large options choice

42N. Room Fan Coils PRODUCT SELECTION DATA. MAINTENANCE INSTRUCTIONS Simpified installation & large options choice PRODUCT SELECTION DATA Extremely quiet operation INSTALLATION, OPERATION AND Low Energy Consumption MAINTENANCE INSTRUCTIONS Simpified installation & large options choice Self regulated PTC electrical

More information

42C/D SERIES Ducted Chilled Water Fan Coil Unit With District Cooling Application

42C/D SERIES Ducted Chilled Water Fan Coil Unit With District Cooling Application 42C/D SERIES Ducted Chilled Water Fan Coil Unit With District Cooling Application MAXIMIZING PERFORMANCE, ENERGY SAVINGS & COMFORT MODEL NUMBER NOMENCLATURE 4 2 C E T 0 0 3 4 7 0 1 2 5 42 series CISB Code

More information

technical sales guide - 60Hz Ducted Split Units HIGH AMBIENT OPERATION 52 UPTO

technical sales guide - 60Hz Ducted Split Units HIGH AMBIENT OPERATION 52 UPTO technical sales guide - 60Hz Taurus R Ducted Split Units UPTO HIGH AMBIENT OPERATION 52 O C Page CONTENTS Nomenclature.. 2 Description. 3 Features.. 3 Product Data. 4 Condensing Unit Cooling Performance

More information

technical catalogue tetris KW Chiller and heat pumps air/water

technical catalogue tetris KW Chiller and heat pumps air/water technical catalogue tetris 110 930 KW Chiller and heat pumps air/water > TETRIS Water chiller > TETRIS /HP Reversible heat pump > TETRIS /ST Water chiller with storage tank and pumps > TETRIS /DC Unit

More information

Fan coil units. Why choose Daikin fan coil units? 540 Products overview 542. Options & accessories 560. Round flow cassette 544 FWC-BT/BF 544

Fan coil units. Why choose Daikin fan coil units? 540 Products overview 542. Options & accessories 560. Round flow cassette 544 FWC-BT/BF 544 Fan coil units Why choose Daikin fan coil units? 540 Products overview 542 Round flow cassette 544 FWC-BT/BF 544 4-way blow ceiling mounted cassettes 545 FWG-AT/AF 545 FWF-BT/BF 546 FWF-CT 547 Floor standing

More information

TECHNICAL GUIDE R410a SPLIT SYSTEM 1.5 to 5.0 NOMINAL TONS

TECHNICAL GUIDE R410a SPLIT SYSTEM 1.5 to 5.0 NOMINAL TONS Version.MDT-2016.T3.103 TECHNICAL GUIDE R410a SPLIT SYSTEM 1.5 to 5.0 NOMINAL TONS FEATURES AND BENEFITS COMPRESSOR: Compressors are protected with internal temperature and current overloads. An internal

More information

VLS (Cooling Only) VLH (Heat Pump Version) VLR (Total Heat Recovery Version)

VLS (Cooling Only) VLH (Heat Pump Version) VLR (Total Heat Recovery Version) R u Air Cooled Water Chillers VLS (Cooling Only) VLH (Heat Pump Version) VLR (Total Heat Recovery Version) Models 524 to 1204 137 to 308 kw 150 to 336 kw Engineering Data Manual EDM VL410-W.2GB Date :

More information

DATA & FACTS Unit Heaters MultiMAXX HB. Quick Selection and Fast Delivery

DATA & FACTS Unit Heaters MultiMAXX HB. Quick Selection and Fast Delivery DATA & FACTS Unit Heaters MultiMAXX HB Quick Selection and Fast Delivery Table of Contents MultiMAXX HB Unit Type Code... 3 About this Catalogue... 4 Overview of Capacity... 5 Unit Description... 6 Unit

More information

HBC SERIES-PSC MOTOR HBCX SERIES-ECM MOTOR

HBC SERIES-PSC MOTOR HBCX SERIES-ECM MOTOR PRODUCT SPECIFICATIONS *HBC(X) *PHBC(X) *RHBC(X) *CHBC(X) Chilled Water/Hot Water 2-pipe/4-Pipe HBC SERIES- HBCX SERIES-ECM MOTOR Ceiling Concealed Horizontal -1 CFM Ceiling Concealed Ceiling Recessed

More information

Ceiling Concealed Chilled Water Fan Coil Unit

Ceiling Concealed Chilled Water Fan Coil Unit Technical Manual MODELS: ACW200 ACW300 ACW400 ACW600 ACW800 ACW1000 ACW1200 Air Flow: 112~2040 m 3 /h ACW - C/F/H - 2009-001 Ceiling Concealed Chilled Water Fan Coil Unit Contents Nomenclature... 2 Features...

More information

YFCN Fan Coil Unit centrifugal fan 2 & 4 pipe system A complete range from 1.0 kw to 7.6 kw

YFCN Fan Coil Unit centrifugal fan 2 & 4 pipe system A complete range from 1.0 kw to 7.6 kw Fan Coil Unit centrifugal fan 2 & 4 pipe system complete range from 1.0 kw to 7.6 kw Water Systems Wired controls R Remote three speeds controller TR R + Electronic thermostat and Summer/Winter switch

More information

^áêëçåâ=ìåáí=åççäéêë=qvoj^ pí~åç~êç=åççäéêë=ïáíü=pí~áåäéëë=píééä=íìäáåö

^áêëçåâ=ìåáí=åççäéêë=qvoj^ pí~åç~êç=åççäéêë=ïáíü=pí~áåäéëë=píééä=íìäáåö ^áêëçåâ=ìåáí=åççäéêë= pí~åç~êç=åççäéêë=ïáíü=pí~áåäéëë=píééä=íìäáåö O `çåíéåíë= page Model indication................................ 2 Eurovent...................................... 2 Capacities.....................................

More information

University of Delaware

University of Delaware SECTION 23 36 00 _ SUMMARY PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Constant/Variable volume supply terminal units. 2. Fan powered terminal units. 3. Exhaust valves B. Related Sections: Section

More information

CLOSE CONTROL UNITS WITH CHILLED WATER COIL

CLOSE CONTROL UNITS WITH CHILLED WATER COIL CLOSE CONTROL UNITS WITH CHILLED WATER COIL COOLING CAPACITY FROM 5 TO 154 kw 230 D 56 The range of chilled water close control units, series, is particularly indicated for use in technological centres,

More information

CGA CXA VGA VXA CG-PRC006-E4

CGA CXA VGA VXA CG-PRC006-E4 Cooling Only or Reversible Air Cooled Water Chiller CGA 075-100-120-150-200-240 CXA 075-100-120-150-200-240 VGA 075-100-120-150-200-240 VXA 075-100-120-150-200-240 Designed with your needs in mind TRANE

More information

Commercial Blower Coil Air Handlers

Commercial Blower Coil Air Handlers Commercial Blower Coil Air Handlers MODEL : BDH(V)B - 048, 065, 080 7400 CMH - 14300 CMH 30 kw - 125 kw BCXB-PRC001-E4 Contents Model Number Description General Specification Standard Features Unit Configuration

More information

GUIDE SPECIFICATIONS. ES Series R-410A

GUIDE SPECIFICATIONS. ES Series R-410A GUIDE SPECIFICATIONS ES Series R-410A GENERAL Units shall be performance certified to ISO standard 13256-1 for Water Loop Pump, Ground Water Pump and Ground Loop Pump applications. Units shall be Underwriter

More information

product selection data Slim design Acoustic comfort 40% smaller footprint Drycoolers 09VE

product selection data Slim design Acoustic comfort 40% smaller footprint Drycoolers 09VE product selection data Slim design Acoustic comfort 40% smaller footprint Drycoolers 09VE Translation of the original document N 20033, 03.2015 Drycoolers Use Drycoolers in this range are mainly designed

More information

VORTICENT C E RANGE Centrifugal fans

VORTICENT C E RANGE Centrifugal fans NEW VORTICENT C E RANGE Centrifugal fans Suitable for domestic, commercial and industrial applications: kitchens, bathrooms, offices, laboratories, factories, shops, laundromats, models, restaurants, bars,

More information

Technical Sales Guide # 040 YDFC 0 1 Page 2

Technical Sales Guide # 040 YDFC 0 1 Page 2 17-18 Technical Sales Guide # 040 YDFC 0 1 Page 2 Technical Sales Guide # 040 YDFC 0 1 Page 3 York China Fan Coil Unit Model Type ST - Standard DC - District Cooling Number of rows 3: 3 Rows 4: 4 Rows

More information

TECHNICAL MANUAL SOFFIO Ducted units

TECHNICAL MANUAL SOFFIO Ducted units TECHNICAL MANUAL SOFFIO Ducted units Page 1 INDEX 1-INTRODUCTION... 4 2-OPERATING LIMITS... 4 3- KEY TO READING CODES... 5 4-TECHNICAL SPECS... 6 5-TECHNICAL DATA (AC motors)... 7 5.1-Unit 2 pipes with

More information

PRODUCT SELECTION DATA. Performance. Flexibility. Intelligence. Energy optimisation. Acoustic optimisation. Drycoolers 09PE

PRODUCT SELECTION DATA. Performance. Flexibility. Intelligence. Energy optimisation. Acoustic optimisation. Drycoolers 09PE PRODUCT SELECTION DATA Performance Flexibility Intelligence Energy optimisation Acoustic optimisation Drycoolers 09PE Translation of the original document N 20030, 02.2017 Use 09PE The 09PE range is particularly

More information

PHCD-Series. Catalog

PHCD-Series. Catalog PCD-Series Catalog odel: PCD Introduction PCD fan coil unit is designed for a fully concealed ceiling installation. The external static pressure(esp) is up to 75Pa. Owing to its low static and low noise,

More information

Chiller. VLC 524 to Air Cooled Condensing Units Engineering Data Manual. 154 to 347 kw

Chiller. VLC 524 to Air Cooled Condensing Units Engineering Data Manual. 154 to 347 kw Chiller VLC 524 to 1204 Air Cooled Condensing Units Engineering Data Manual 154 to 347 kw Outstanding Strength Points Units with R410A refrigerant (it will be the real replacement of R22). As near azeotropic

More information

ACOUSTIC CABINET FANS CENTRIBOX CVB/CVT. Acoustic cabinet fans. Circular duct connection flanges. Flame retardant IP55 remote terminal box

ACOUSTIC CABINET FANS CENTRIBOX CVB/CVT. Acoustic cabinet fans. Circular duct connection flanges. Flame retardant IP55 remote terminal box ACOUSTIC CABINET FANS CENTRIBOX CVB / CVT Series Cabinet fans manufactured from heavy gauge galvanised steel sheet and internally lined with melamine foam flame retardant acoustic insulation (M1). All

More information

Chilled Water FCU. Horizontal Fan Coil 50hz CFM. A Series.

Chilled Water FCU. Horizontal Fan Coil 50hz CFM. A Series. Chilled Water FCU A Series 3-25 CFM Horizontal Fan Coil 5hz www.windind.com CONTENTS GENERAL CONSTRUCTION... 3 MODEL NUMBER NOMENCLA TURE... 4 DIMENSIONS... 5 FAN PERFORMANCE DATA... 7 GENERAL SPECIFICATIONS...

More information

DIRECT-AIR ILB / ILT Series Rectangular duct fans

DIRECT-AIR ILB / ILT Series Rectangular duct fans IN-LINE DUCT FAN Series Rectangular duct fans Range of in-line rectangular duct fan manufactured from galvanised steel sheet and provided with an inspection cover that can be removed to access the motor/impeller

More information

Centrifugal fan with highly efficient EC drive motor

Centrifugal fan with highly efficient EC drive motor Centrifugal fan with highly efficient EC drive motor simple and safe application and installation 2 Why HLU? 90 years of experience in the plastics processing market More than 10.000 m² production in Germany

More information

D M S 760 C01 A A 1 1

D M S 760 C01 A A 1 1 CONTENTS Description Features Options Available Selection Method Product Data Cooling Performance Data (85 F Ambient Cooling Performance Data (95 F Ambient) Cooling Performance Data (105 F Ambient)..............................

More information

NH 3. Evaporator. Ammonia Applications Tons MANP

NH 3. Evaporator. Ammonia Applications Tons MANP NH 3 Evaporator Ammonia Applications 12-108 Tons > > Used for medium TO large Industrial Ammonia applications Manufactured with Stainless steel tubes. The Global Leader In Heat Exchange Technology With

More information

NEOSTAR NEW! Condensers. www. 18 kw 1250 kw

NEOSTAR NEW! Condensers. www. 18 kw 1250 kw Condensers NEOSTAR 18 kw 12 kw Friga-Bohn reserves itself the right to make changes at any time without preliminary notice - Photos non-contractual www NEW! The air cooled condenser units of the new NEOSTAR

More information

PVHRU Max Quiet. Engineering Solutions. Packaged Void Heat Reclaim Unit. Acoustic Testing Laboratory College of Science & Technology

PVHRU Max Quiet. Engineering Solutions. Packaged Void Heat Reclaim Unit. Acoustic Testing Laboratory College of Science & Technology AIR HANDLERS LTD PVHRU Max Quiet Packaged Void Heat Reclaim Unit 1262 Acoustic Testing Laboratory College of Science & Technology Engineering Solutions The Company Air Handlers has been trading since May

More information

SINGLE PACKAGE AIR CONDITIONING WATER COOLED

SINGLE PACKAGE AIR CONDITIONING WATER COOLED MODELS: CU060-300 5-25 TONS VERTICAL SINGLE PACKAGE AIR CONDITIONING WATER COOLED MODELS: CH060-5-10 TONS HORIZONTAL FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE TABLE OF CONTENTS

More information

VERTICAL SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING WITH HOT WATER OR ELECTRIC HEAT

VERTICAL SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING WITH HOT WATER OR ELECTRIC HEAT VERTICAL SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING WITH HOT WATER OR ELECTRIC HEAT SIZES FROM 600 TO 4,000 All Technical Specifications are Subject to Change without Notice.

More information

TECHNICAL DOCUMENTATION WOLF AIR HEATERS LH-EC / LH. 30m 3 /h

TECHNICAL DOCUMENTATION WOLF AIR HEATERS LH-EC / LH. 30m 3 /h TECHNICAL DOCUMENTATION WOLF AIR HEATERS LH-EC / LH 30m 3 /h THE EXTENSIVE EQUIPMENT RANGE from system supplier WOLF offers the ideal solution for commercial and industrial buildings, new build and modernisation

More information

HRS. Very high efficiency heat recovery units. from 300 to m³/h >90 % WITH HIGH EFFICIENCY HEAT RECOUPERATOR

HRS. Very high efficiency heat recovery units. from 300 to m³/h >90 % WITH HIGH EFFICIENCY HEAT RECOUPERATOR 4 Lmf Clima 6 FERRARO GROUP HRS Very high efficiency heat recovery units WITH HIGH EFFICIENCY HEAT RECOUPERATOR from 3 to 4. m³/h Air-handling unit designed and manufactured for nonresidential applications,

More information

DXP 100 Air Cooled Condenser

DXP 100 Air Cooled Condenser Air Cooled Condenser Applied for CERTIFY-ALL DX COOLERS PRESENTATION The coolers are designed for outdoor applications. All technical data are based on different mixtures of cooling media i.e.ethylene

More information

product selection data Performance Flexibility Intelligence Energy optimisation Acoustic optimisation Drycoolers - Air-cooled condensers 09PE

product selection data Performance Flexibility Intelligence Energy optimisation Acoustic optimisation Drycoolers - Air-cooled condensers 09PE product selection data Performance Flexibility Intelligence Energy optimisation Acoustic optimisation Drycoolers - 09PE Translation of the original document N 20030, 03.2015 Use The 09PE range, available

More information