Hydropac. Waterside Control Fan Coil Units For Horizontal and Vertical Applications. June Hydropac. Features

Size: px
Start display at page:

Download "Hydropac. Waterside Control Fan Coil Units For Horizontal and Vertical Applications. June Hydropac. Features"

Transcription

1 June 2003 Hydropac Hydropac Waterside Control Fan Coil Units For Horizontal and Vertical Applications Features Flush panel extra rigid construction. Low noise levels. Eleven speed transformer. Full acoustic and thermal insulation. Various filter options. All types of controls available, fitted and wired. Outputs available up to 6.4kW cooling and 6.9kW heating. Horizontal Hydropac PHW173 Illustrated Designed and Built in Britain Patent Nos. Pending

2 Hydropac PHW230 and PHW170 Series Hydropac (Series PHW) Actionair Hydropac horizontal ceiling void mounted type fan coils are waterside control, suitable for operation against moderate duct resistances, using chilled water cooling medium and low pressure hot water heating medium. Temperature control is by means of modulating 4-port diverting valves on heating and cooling, operated by stand alone or BMS controller with room or return air temperature sensor. Designated PHW, the series consists of standard 230mm (PHW230) deep and slimline 170mm (PHW170) deep versions. Robust construction 1.6mm top panel and fan deck, all other panels 1.2mm galvanised steel. Interchangeable spun steel spigots and insulated blanking plates. High quality EBM Ziehl external rotor motor fans. Fully insulated with Class O open cell thermal and acoustic foam. Quick installation with recessed reinforced slotted mounting points. 2

3 Hydropac Detail Construction Easy filter removal with three filter options: EU3 Filter Media. EU2 Metal Mesh. Commissioning filter (EU2 Metal Mesh + Media Filter.) High performance coils with vents and drains. Circuited to provide full contra flow. Pipe support plate. Insulated removable powder coated drain tray, with connection options. Illuminated on/off switch with 3 speed fan and fine adjustment switches. Giving 9 speeds on exterior of units. Enclosure incorporating 11 speed transformer with 24 volt output for FCU controller. 3

4 Hydropac PHW 230 Series PHW 230 Series Waterside control 230mm deep ceiling void mounted chassis unit Thermal Performance Data 11 C min air off 14 C min air off ChW 6 C flow, 11 C return ChW 10 C flow,14 C return LPHW 82 C flow 72 C return Model Speed Airflow Sensible Total Sensible/Total Cooling Heating Fan Input N.R. Setting (I/s) Cooling Cooling (Watts) (Watts) (Watts) Guide* (Watts) (Watts) PHW PHW PHW232X PHW PHW PHW234X PHW PHW235X The Fan Coil selections are based on the following entering air conditions: Cooling: Summer On-coil air 23 C Dry Bulb, 16 C Wet Bulb. Max Coil Pd = 20kPa Heating: Winter On-coil air temperature 20 C Dry Bulb. Max Coil Pd = 10kPa General: External Resistance 30Pa. Electrical Supply 230 Volts/ 1 phase /50 Hz. Please refer to our Fan Coil Technical Department for alternative conditions. * see page 7 for NR Predictor. 4

5 Hydropac PHW 230 Series PHW 230 Series Dimensions Model Dim A Dim B Weights Spigots PHW kg PHW 232/2X kg PHW kg PHW 234/4X kg PHW 235/5X kg

6 Hydropac PHW 170 Series PHW 170 Series Waterside control 170mm deep ceiling void mounted chassis unit Thermal Performance Data 11 C min air off 14 C min air off ChW 6 C flow, 11 C return ChW 10 C flow,14 C return LPHW 82 C flow 72 C return Model Speed Airflow Sensible Total Sensible/Total Cooling Heating Fan Input N.R. Setting (I/s) Cooling Cooling (Watts) (Watts) (Watts) Guide* (Watts) (Watts) PHW PHW PHW PHW The Fan Coil selections are based on the following entering air conditions: Cooling: Summer On-coil air 23 C Dry Bulb, 16 C Wet Bulb. Max Coil Pd = 20kPa Heating: Winter On-coil air temperature 20 C Dry Bulb. Max Coil Pd = 10kPa General: External Resistance 30Pa. Electrical Supply 230 Volts/ 1 phase /50 Hz. Please refer to our Fan Coil Technical Department for alternative conditions. * see page 7 for NR Predictor. Dimensions Unit Dim A Dim B Dim C Weight SPIGOT OPTIONS PHW kg PHW kg PHW kg PHW kg

7 Hydropac PHW 230 / 170 Series Acoustic Performance Data Typical Horizontal Fan Coil Unit Arrangement Fresh air supply duct. Fan coil unit. Minimum 1 metre length Sonodec 25 acoustic flex. Diffuser plenum. Building structure. Wall/glazing. Return air grille/diffuser (not positioned directly below unit intakes). T Bar grid false ceiling with either 10mm thick fibre board tiles or insulated metal pan tiles. Internal room. * Notes on NR predictions NR predictions quoted are based upon extensive acoustic independent tests to the above arrangement and are intended as a guide to levels which can be expected. The following qualifications must apply:- Units must be mounted correctly, using rubber washers, onto a solid structure. The units should be mounted into a false ceiling of not less than 300mm deep, constructed of a standard T bar grid with 10mm thick fibre board tiles or insulated metal pan tiles. Rooms of open plan or partitioned design should be furnished, carpeted and have no more than 20% glass area with no highly reflective surfaces such as ceramic tiles etc. Where a single unit is serving a room the dimensions should be based upon a cooling load of 120w/sq.m e.g a unit giving 1.2kW total cooling output should be serving a room with a floor area of not less than 10sq.m. In an open plan area units should be mounted at a minimum of 4.5m centres and no closer than 1.5m from a corner. Return air grilles should not be positioned directly below unit intakes. At least 1m of acoustic flexible ducting (Sonodec 25 or similar) is used on each spigot outlet. A maximum air velocity of 3.0m/s per outlet spigot to achieve NR35. The above should give the predicted Lp at 1.5m from the nearest diffuser. For detailed acoustic data of Inlet/Casing Radiated and Discharge Sound Power Levels, please refer to Actionair Sales Office. 7

8 Hydropac PVW230 Series Detail Constru Hydropac (Series PVW) Actionair vertical chassis and cased wall mounted fan coils are waterside control, suitable for free-blow, applications or vertical ducted arrangements operating up to 60 Pa external resistance, using chilled water cooling medium and low pressure hot water medium. Temperature control is by means of modulating 4-port diverting valves on heating and cooling. Designated PVW the series consists of five models 230mm deep, with six non-cased/cased variations. Protected control enclosure. Discharge spigot can be vertical or horizontal. Slide out filters. EBM Ziehl external rotor motor fans. Condensate removal pump when used. Removable front access. 8

9 Hydropac ction PVW 230 Cases Options and Mounting Arrangements Option 1. Low level mounting with front angled grille outlet. Option 2. Low level mounting with front angled grille outlet and front face grille inlet. Option 3. High level mounting as per option 2 but with protection panel on underside. Option 4. High level mounting with front grille outlet and underside grille inlet. 9

10 Hydropac Series PVW 230 PVW 230 Series 230mm deep vertical wall mounted chassis / cased units Thermal Performance Data 11 C min air off 14 C min air off ChW 6 C flow, 11 C return ChW 10 C flow, 14 C return LPHW 82 C flow 72 C return Model Speed Airflow Sensible Total Sensible/Total Cooling Heating Fan Input N.R. Setting (I/s) Cooling Cooling (Watts) (Watts) (Watts) Guide* (Watts) (Watts) PVW PVW PVW PVW PVW The Fan Coil selections are based on the following entering air conditions: Cooling: Summer On-coil air 23 C Dry Bulb, 16 C Wet Bulb. Max Coil Pd = 20kPa Heating: Winter On-coil air temperature 20 C Dry Bulb. Max Coil Pd = 10kPa General: External Resistance 10Pa. Electrical Supply 230 Volts/ 1 phase /50 Hz. * see page 11 for NR Predictor. Chassis Dimensions Unit Dim A Dim B Weight PVW kg PVW kg PVW kg PVW kg PVW kg 10

11 Hydropac Series PVW 230 PVW 230 Series * Notes on NR predictions Case Dimensional Data NR predictions are based upon extensive acoustic independent tests and are intended as a guide to levels which can be expected, when measured at 2.0m. The following qualifications apply:- Units must be mounted correctly, using fixing points provided onto a flat, solid surface, such as concrete or brick wall in such a way that they are not subjected to undue stress and are checked for accuracy of horizontal levelling. Rooms of open plan or partitioned design should be furnished, carpeted and have no more than 20% glass area with no highly reflective surfaces such as ceramic tiles etc. Where a single unit is serving a room the dimensions should be based upon a cooling load of 120w/sq.m e.g a unit giving 1.2kW total cooling output should be serving a room with a floor area of not less than 10sq.m. In an open plan area units should be mounted at a minimum of 3m centres and no closer than 1.5m from a corner. Units installed in accordance with the above should give the predicted N.R. level when measured at a distance of 2.0m from any surrounding flat surface. For detailed acoustic data of Radiated Sound Power Levels, please refer to Technical Sales Office. Option 1 Case Option 2 and 3 Case Option 4 Case Unit Dim A Dim B Weight PVW kg PVW kg PVW kg PVW kg PVW kg 11

12 Actionair Also available NEW Environpac EMC Motor Technology 40% Less Motor Energy 1/3 Less Fan Heat Constant Volume NEW Systempac Fancoil, Ductwork and Diffuser Package Fast Track Delivery Fully Acoustically Tested Sample Design Selection Aeropac Airside Control Fancoil 230mm Deep Horizontal Mounted High Energy Efficiency Technical Support Actionair provide quality products backed by a dedicated team committed to providing the very best in customer service. Specialist response from the Actionair Sales Team, administrative response from the Computerised Sales Office and product maintenance from the Team of Experienced Service Engineers, who understand fully the needs of the industry. Actionair Products For information on our comprehensive range of Fire, Smoke and Air Control Dampers, as well as Application, Technical and Pricing Advice, please refer to the Actionair Sales Office. NO COMPROMISE Quality System Certificate No 017 Assessed to ISO 9001 : 2000 Actionair, South Street, Whitstable, Kent CT5 3DU England Tel: (01227) Fax: (01227) International Code: sales@actionair.co.uk Website: The information contained herein is subject to change without notice due to continuing research and development. PRODUCED BY GRAPHIC PARTNERSHIP Part of Ruskin Air Management Limited

Systempac. Fan Coil Unit / Acoustic Flex / Diffuser System Package. Systempac. January Features and Design Guide

Systempac. Fan Coil Unit / Acoustic Flex / Diffuser System Package. Systempac. January Features and Design Guide January 2002 Systempac Features and Design Guide Specifically Designed for Design and Build Projects. Complete package including Waterside Control Fan Coil Unit / Controls / Flexible Ducting / Plenum Box

More information

Sapphire Horizontal Waterside Control Fan Coil Units

Sapphire Horizontal Waterside Control Fan Coil Units Sapphire Horizontal Waterside Control Fan Coil Units Introduction The Quartz SAPPHIRE series is a compact, high output fan coil unit capable of meeting exacting heating and cooling requirements whilst

More information

Chassis Access Fans Motors Speed Control Coils The Condensate Tray Insulation Spigots Controls Enclosure Control Valves Filters Rev A

Chassis Access Fans Motors Speed Control Coils The Condensate Tray Insulation Spigots Controls Enclosure Control Valves Filters Rev A Chassis panelwork is all In House manufactured from nominally 1.2mm Galvanised steel. Where at all possible, flanges are formed inward facing to prevent exposure to bare metal edges. Sufficient forms and

More information

Highline 260i EC Waterside Fan Coil Unit

Highline 260i EC Waterside Fan Coil Unit Features: Electronically Commutated (EC) fan motor Specific Fan Power of 0.16 to 0.34 at NR Insignificant fan heat gain Designed to operate below NR at External Static Pressures of up to 50Pa Variable

More information

Actionair Control and Shut Off Dampers

Actionair Control and Shut Off Dampers December 2003 Air/Shield (Incorporating Energy/Shield ES35 & ES36) Actionair Control and Shut Off Dampers Air/Shield Aerofoil Air Control Dampers Air/Shield Aeroseal Air Control and Shut-Off Dampers Energy/Shield

More information

Features: Concealed installation. Compact design. Available in electric, LPHW or ambient.

Features: Concealed installation. Compact design. Available in electric, LPHW or ambient. Features: Concealed installation. Compact design. Available in electric, LPHW or ambient. Grille can be supplied in a large range of colours. Energy saving controls option available. Application The Diffusion

More information

The World Leading Air-conditioning Company

The World Leading Air-conditioning Company The World Leading Air-conditioning Company Table of Contents DESCRIPTIONS Model Number Nomenclature Features & Benefits Physical Dimension Fan Performance Curve (4 Row) - 40LMA024 with AC Motor - 40LMA040

More information

Blade Features. AirShield Control and Shut Off Dampers. AirShield

Blade Features. AirShield Control and Shut Off Dampers. AirShield April 2011 AirShield AirShield AirShield Aerofoil Air Control Dampers AirShield Aeroseal Air Control and Shut Off Dampers AirShield Features and Design Guide Opposed blade dampers suitable for systems

More information

NEW. Iris Control Damper (ICD) For adjustment and measuring of airflow. Features. Quick and simple installation and maintenance

NEW. Iris Control Damper (ICD) For adjustment and measuring of airflow. Features. Quick and simple installation and maintenance March 29 Iris Control Damper (ICD) NEW Iris Control Damper (ICD) For adjustment and measuring of airflow Features Quick and simple installation and maintenance Extended spigot connections 1% opening capacity

More information

EnergyShield ES. Air Control and Shut off Dampers. Dampers Controls Fancoils. Ruskin Air Management Limited

EnergyShield ES. Air Control and Shut off Dampers. Dampers Controls Fancoils. Ruskin Air Management Limited April 11 EnergyShield ES EnergyShield ES Air Control and Shut off Dampers Features Dampers suitable for systems requiring air control and low closed blade leakage characteristics. Low torque characteristics.

More information

Actionair A-60 Marine Fire Damper Designed for inclusion in Marine and Offshore Projects

Actionair A-60 Marine Fire Damper Designed for inclusion in Marine and Offshore Projects March 06 A-60 Marine Fire Dampers Tests and Approvals A60 Fire Rated. Lloyds Register of Shipping Approved. Marine Equipment Directive compliant. USCG Approved. Germanischer Lloyds Approved. American Bureau

More information

INHERENTLY QUIET AND POWERFUL 180 MM DEEP SLIMLINE HORIZONTAL WATERSIDE CONTROL IN CEILING

INHERENTLY QUIET AND POWERFUL 180 MM DEEP SLIMLINE HORIZONTAL WATERSIDE CONTROL IN CEILING INHERENTLY QUIET AND POWERFUL 180 MM DEEP SLIMLINE HORIZONTAL WATERSIDE CONTROL IN CEILING The Cougar, manufactured by Dunham-Bush is a high quality, compact, slim-line range of fan coil units, designed

More information

Floor Swirls Models BZD and SZD

Floor Swirls Models BZD and SZD July 09 Floor Swirls Floor Swirls Models BZD and SZD Features Model BZD Circular Floor Swirl Model SZD Circular Step Diffuser Grilles Diffusers Louvres Chilled Beams Ruskin Air Management Limited www.ruskinuk.co.uk

More information

PVHRU Max Quiet. Engineering Solutions. Packaged Void Heat Reclaim Unit. Acoustic Testing Laboratory College of Science & Technology

PVHRU Max Quiet. Engineering Solutions. Packaged Void Heat Reclaim Unit. Acoustic Testing Laboratory College of Science & Technology AIR HANDLERS LTD PVHRU Max Quiet Packaged Void Heat Reclaim Unit 1262 Acoustic Testing Laboratory College of Science & Technology Engineering Solutions The Company Air Handlers has been trading since May

More information

Engineering Data Manual. New : available with EC motor. High Static Pressure Ductable Fan Coil Unit. Models 07 to to 4650 m 3 /h

Engineering Data Manual. New : available with EC motor. High Static Pressure Ductable Fan Coil Unit. Models 07 to to 4650 m 3 /h Engineering Data Manual New : available with EC motor VH High Static Pressure Ductable Fan Coil Unit Models 07 to 27 800 to 4650 m 3 /h General Characteristics Presentation On model VH 07, coils have 4

More information

LINEAR BAR GRILLES T SERIES. Quality and e!ciency without compromise

LINEAR BAR GRILLES T SERIES. Quality and e!ciency without compromise LINEAR BAR GRILLES T SERIES Quality and e!ciency without compromise Weltech Business Centre - Ridgeway - Welwyn Garden City - Hertfordshire AL7 2AA Tel: 01707 871526 - Fax: 01707 871 527 - email sales@jprservices.co.uk

More information

Linear Slot Diffusers Model Slot 20 and Model Slot 25

Linear Slot Diffusers Model Slot 20 and Model Slot 25 December 06 Linear Slot Diffusers Linear Slot Diffusers Model Slot and Model Slot 25 Features 1 to 8 Slots mm or 25mm Slot widths Ceiling or Sidewall Applications Modular or Continuous Lengths Curved Sections

More information

Modular Air Handling. Up to 3,500 Litres / sec. Low profile & Plant room application. Draft. Version. Second Edition A-. AirDesign 2015 AirDesign 2016

Modular Air Handling. Up to 3,500 Litres / sec. Low profile & Plant room application. Draft. Version. Second Edition A-. AirDesign 2015 AirDesign 2016 Modular Air Handling U n i t R a n g e Up to 3,500 Litres / sec Low profile & Plant room application AirDesign 2015 AirDesign 2016 Second Edition Draft Version A-. Air Design is a proud Australian based

More information

Chiller, Close control and Water terminals. Air Conditioning. Light Commercial, Commercial and Industrial

Chiller, Close control and Water terminals. Air Conditioning. Light Commercial, Commercial and Industrial Chiller, Close control and Water terminals Air Conditioning Light Commercial, Commercial and Industrial Water Terminals 133 Water Terminals Fan coils & Cassette Centrifugal fan-coil SYSCOIL Ductable fan-coil

More information

Ocelot vertical fan coil unit

Ocelot vertical fan coil unit Ocelot vertical fan coil unit 250mm Deep vertical Waterside control Cased unit DUNHAM BUSH OCELOT VERTICAL CASED FAN COIL UNIT The Dunham Bush Ocelot fan coil unit is a fully cased vertical unit suitable

More information

Water terminals from 91 to 1548 m 3 /h. from 0,5 to 9,6 kw. SysCoil Comfort. Floor and ceiling fan coil units. from 0,6 to 13,6 kw

Water terminals from 91 to 1548 m 3 /h. from 0,5 to 9,6 kw. SysCoil Comfort. Floor and ceiling fan coil units. from 0,6 to 13,6 kw Water terminals from 91 to 1548 m 3 /h SysCoil Comfort Floor and ceiling fan coil units from 0,5 to 9,6 kw from 0,6 to 13,6 kw SysCoil Comfort Innovation for an optimum comfort ErP 2018 TERTIAIRY H 3 /h

More information

ULTRA LOW ENERGY. VHR Void Series W/I/s TOTAL SFP Typical. Made in the UK. VHR Void Mounted Heat Recovery Units VHR PERFORMANCE OVERVIEW:

ULTRA LOW ENERGY. VHR Void Series W/I/s TOTAL SFP Typical. Made in the UK. VHR Void Mounted Heat Recovery Units VHR PERFORMANCE OVERVIEW: VHR Void Mounted Heat Recovery Units TM.72 W/I/s TOTAL SFP Typical General: Units shall be manufactured from high quality galvanized sheet steel with stainless steel drain trays, acoustic, non-hygroscopic

More information

FlowBar High Capacity Slot Diffuser

FlowBar High Capacity Slot Diffuser October 2016 FlowBar High Capacity Diffuser Model HT (High Throw) Model JT (Jet Throw) Features HT & JT 25mm, 38mm, 51mm, 63mm & 76mm s Ceiling or Sidewall Applications Modular or Continuous s Curved Sections

More information

IrisControlDamper. For Adjustment and Measuring of Airflow.

IrisControlDamper. For Adjustment and Measuring of Airflow. IrisControlDamper For Adjustment and Measuring of Airflow www.actionair.co.uk sales@actionair.co.uk Iris Control Damper (ICD) Quick, silent and efficient is the simple summary of the features of the Actionair

More information

KLIMA Active Chilled Beams

KLIMA Active Chilled Beams KLIMA 2 600 Active Chilled Beams 0 Index Subject Page Index 1 Introduction 2 General description 3-4 Product features 5-6 Dimensions 7 Performance data 8-11 Selection example 12 Guide specifications 13

More information

Features: Available in horizontal and vertical units

Features: Available in horizontal and vertical units Features: Available in horizontal and vertical units Ideal for Shopping Malls, Retail Outlets and Office Receptions Can be supplied in a large range of colours and finishes Numerous mounting bracket arrangements

More information

MAJOR 2 NCH. Ductable units. High pressure and high capacity ductable units RANGE NCH Y NCH NCH I COADIS COMBI. Motor optional

MAJOR 2 NCH. Ductable units. High pressure and high capacity ductable units RANGE NCH Y NCH NCH I COADIS COMBI. Motor optional Y + U I COADIS COMBI High pressure and high ductable units Motor optional is a non independent air conditioning terminal unit for heating and cooling offices and hotels. With reduced dimensions and designed

More information

TransShield Mode 1/2. Transfer Stainless Steel Sliding Plate Fire Dampers.

TransShield Mode 1/2. Transfer Stainless Steel Sliding Plate Fire Dampers. TransShield Mode 1/2 Transfer Stainless Steel Sliding Plate Fire Dampers www.actionair.co.uk sales@actionair.co.uk Introduction The TransShield Modes 1 and 2 stainless steels stainless steel sliding plate

More information

Ductable Modular Fan Coil Unit VPX. Technical Brochure TM VPX-W.2GB Date : May 2004 Supersedes : TM VPX-W.1GB/08.03

Ductable Modular Fan Coil Unit VPX. Technical Brochure TM VPX-W.2GB Date : May 2004 Supersedes : TM VPX-W.1GB/08.03 Ductable Modular Fan Coil Unit VPX Technical Brochure TM VPX-W.2GB Date : May 2004 Supersedes : TM VPX-W.1GB/08.03 Design Features Presentation The VPX fan coil unit has been specially designed to meet

More information

BUILDING EFFICIENCY Energy Efficient Variable Speed EC Motor Fan Coil Unit Solutions Model YECFC

BUILDING EFFICIENCY Energy Efficient Variable Speed EC Motor Fan Coil Unit Solutions Model YECFC BUILDING EFFICIENCY Energy Efficient Variable Speed EC Motor Fan Coil Unit Solutions Model YECFC Product Introduction INTRODUCTION Johnson Controls YORK YECFC fan coil units are high efficiency, low profile,

More information

Cell Ventilation Security Grille

Cell Ventilation Security Grille June 2010 Cell Ventilation Security Grille Cell Ventilation Security Grille Model CV Features Stainless Steel Construction Galvanised Steel/ PPC Construction Supply and Exhaust Tested "Fit For Purpose"

More information

Fan - Powered Terminal Unit Series Flow

Fan - Powered Terminal Unit Series Flow 5/22/M/1 Fan - Powered Terminal Unit Series Flow Type TFP Trox (Malaysia) Sdn Bhd 20 Persiaran Bunga Tanjung 1 Senawang Land Industrial Park 70400 Seremban Negeri Sembilan Darul Khusus Malaysia Telephone

More information

Total comfort control

Total comfort control Total comfort control YORK ACTIVE CHILLED BEAM WITH PERFORATED RETURN DIFFUSER Table of contents Concept & Technology Air Distribution & Facade Orientation Product Features Dimensions Performance Data

More information

HIGH CAPACITY LINEAR SLOT DUFFUSERS

HIGH CAPACITY LINEAR SLOT DUFFUSERS HIGH CAPACITY LINEAR SLOT DUFFUSERS CB SERIES Quality and efficiency without compromise Weltech Business Centre - Ridgeway - Welwyn Garden City - Hertfordshire AL7 2AA Tel: 01707 871526 - Fax: 01707 871

More information

AHTW Compact. Heat Recovery Air Handling Unit. BIM & REVIT Engineering Solutions. Acoustic Testing Laboratory College of Science & Technology

AHTW Compact. Heat Recovery Air Handling Unit. BIM & REVIT Engineering Solutions. Acoustic Testing Laboratory College of Science & Technology HANDLERS LTD AHTW Compact Heat Recovery Air Handling Unit 1262 Acoustic Testing Laboratory College of Science & Technology BIM & REVIT Engineering Solutions The Company Air Handlers has been trading since

More information

High Performance Fan Coils FCHG Genesis Series Horizontal

High Performance Fan Coils FCHG Genesis Series Horizontal Dimensional Data 5 7 /8 (150) D 14 (356) 2 (51) Diverter - Slides Into Discharge Ductwork Optional: Second Drain Pan Connection E Coil Section X Dimensional Data - IP (in.) / SI [mm] Unit Fan Outlet Duct

More information

SINGLE DUCT TERMINAL UNITS

SINGLE DUCT TERMINAL UNITS www.igcaire.com SINGLE DUCT TERMINAL UNITS Direct Digital Control, Pressure Independent FEATURES 22 Gauge Galvanized Steel Casing Construction with a 20 Gauge Casing Option that Provides Strength and Product

More information

Linear Slot Diffusers Model Slot 20 & Model Slot 25

Linear Slot Diffusers Model Slot 20 & Model Slot 25 Model Slot & Model Slot 25 Contents Introduction!!!!!! Page 3 Di"user Specification!!!! Page 4 Air Patterns!!!!!! Page 5 Flange Styles!!!!!! Page 6 Corner Sections!!!!! Page 7 Selection Procedure!!!! Page

More information

Guide Specifications. General. Casing. Coil/Drain pan. Fan/Motor

Guide Specifications. General. Casing. Coil/Drain pan. Fan/Motor Guide Specifications General CR-A series ducted concealed chilled water fan coil units have an air flow range from 45 to 3060 cubic meters per hour with a capacity range from kw up to 9 kw. The CR-A series

More information

BRIZA 22 HYBRID HEATING & COOLING

BRIZA 22 HYBRID HEATING & COOLING BRIZA 22 HYBRID HEATING & COOLING Built-in Ceiling: BABC/BT BABC/FT Built-in Wall: BABW/BT BABW/BF BABW/FT BABW/FF INFO SHEET BRIZA 22 HYBRID, COMPACT FANCOIL With EC Greentech EBM-PAPST technology Europe

More information

UTA STANDARD. Ductable units. Range. Air handling unit with high available static pressure. NEW Eco-Design Filter. V3000 control Fresh air management

UTA STANDARD. Ductable units. Range. Air handling unit with high available static pressure. NEW Eco-Design Filter. V3000 control Fresh air management Ductable units NEW Eco-Design Filter Air handling unit with high available static pressure V3000 control Fresh air management The range of air handling units is designed for suspended ceiling heating and

More information

Product Data. Features/Benefits. 35K Bypass Terminal. 110 to 4400 cfm

Product Data. Features/Benefits. 35K Bypass Terminal. 110 to 4400 cfm Product Data 35K Bypass Terminal 110 to 4400 cfm Carrier s 35K Series bypass terminals offer: 20-gage, galvanized steel casing construction 1/2-in. thick, dual density fiberglass insulation meeting NFPA

More information

Technical Sales Guide # 040 YDFC 0 1 Page 2

Technical Sales Guide # 040 YDFC 0 1 Page 2 17-18 Technical Sales Guide # 040 YDFC 0 1 Page 2 Technical Sales Guide # 040 YDFC 0 1 Page 3 York China Fan Coil Unit Model Type ST - Standard DC - District Cooling Number of rows 3: 3 Rows 4: 4 Rows

More information

Catalogue. FlowBar. High Capacity Slot Diffuser.

Catalogue. FlowBar. High Capacity Slot Diffuser. Catalogue FlowBar High Capacity Slot Diffuser www.air-diffusion.co.uk sales@air-diffusion.co.uk Content Introduction... 4 Diffuser Specification... 5 Air Patterns... 6 Flange Styles... 7 Curved Sections...

More information

500-YVI PARALLEL FAN-POWERED AIR TERMINAL UNIT FORM EG3 (404)

500-YVI PARALLEL FAN-POWERED AIR TERMINAL UNIT FORM EG3 (404) 500-YVI PARALLEL FAN-POWERED AIR TERMINAL UNIT Table of Contents Introduction...3 500-YVI Features...4-5 Dimensional Data...6-7 ARI Rating Points...8 Statement of Standard Test Conformity...8 Motor Amperage

More information

C O L M A N. Air Distribution LINEAR BAR GRILLES T SERIES SERIES

C O L M A N. Air Distribution LINEAR BAR GRILLES T SERIES SERIES C O L M A N Air Distribution E N G I N E E R E D A I R P R O D U C T S LINEAR BAR GRILLES T SERIES T SERIES C O L M A N Air Distribution E N G I N E E R E D A I R P R O D U C T S LINEAR BAR GRILLES T SERIES

More information

AMOUNT IN Rs After adding percentage above or at par or below In In words figures. ESTIMATED COST (IN Rupees) In figures. In words

AMOUNT IN Rs After adding percentage above or at par or below In In words figures. ESTIMATED COST (IN Rupees) In figures. In words Tender for " CONSTRUCTION OF SUPER SPECIALITY HOSPITAL FOR GOVT. RAJAJI MEDICAL COLLEGE, MADURAI, TAMIL NADU HEATING VENTILATION AND AIR CONDITIONING WORKS NIT No. SRO/MKT/TH/289 Dated 02/07/2014 SL. No.

More information

Fan Coil Dimensional Data. ultimate fan coil system

Fan Coil Dimensional Data. ultimate fan coil system Fan Coil Dimensional Data ultimate fan coil system Overview In this literature we aim to provide dimensional data on the main Ability Fan Coil Ranges.. However, Matrix and EVO units are available in other

More information

500-YCI SERIES FAN-POWERED AIR TERMINAL UNIT FORM EG2 (404)

500-YCI SERIES FAN-POWERED AIR TERMINAL UNIT FORM EG2 (404) 500-YCI SERIES FAN-POWERED AIR TERMINAL UNIT Table of Contents General Information...3 500-YCI Features...4-5 Dimensional Data...6-7 ARI Rating Points...8 Statement of Standard Test Conformity...8 Motor

More information

VAV/CAV BOXES COMMERCIAL BUILDINGS INNOVATIVE VENTILATION & HEATING

VAV/CAV BOXES COMMERCIAL BUILDINGS INNOVATIVE VENTILATION & HEATING VAV/CAV BOXES COMMERCIAL BUILDINGS A guide to VAV/CAV, including our unique product range, consultancy service and accessories. INNOVATIVE VENTILATION & HEATING www.pricetwa.co.uk At Price TWA we believe

More information

CENTRIFUGAL FAN COIL UNIT VCE

CENTRIFUGAL FAN COIL UNIT VCE CENTRIFUGAL FAN COIL UNIT VCE 0,51 kw 11,00 kw 0,85 kw 23,75 kw 129 m 3 /h 2003 m 3 /h VCE DESIGN QUALITY COMFORTRELIABILITY 3VERSION12 SIZE DESIGN VCEx0 vertical with cabinet Air intake: bottom vertical

More information

Chilled Water FCU. Horizontal Fan Coil 50hz CFM. A Series.

Chilled Water FCU. Horizontal Fan Coil 50hz CFM. A Series. Chilled Water FCU A Series 3-25 CFM Horizontal Fan Coil 5hz www.windind.com CONTENTS GENERAL CONSTRUCTION... 3 MODEL NUMBER NOMENCLA TURE... 4 DIMENSIONS... 5 FAN PERFORMANCE DATA... 7 GENERAL SPECIFICATIONS...

More information

Perforated Face Ceiling Diffusers

Perforated Face Ceiling Diffusers February 2011 Perforated Face Ceiling Diffusers Perforated Face Ceiling Diffuser Models PD, DFP and DPP Features NEW DROP PLQUE DESIGN 3 Model Types 1, 2, 3 or 4 way ir Patterns Extruded luminium Sections

More information

AHPHX Compact. Heat Recovery Air Handling Unit. BIM & REVIT Engineering Solutions. Acoustic Testing Laboratory College of Science & Technology

AHPHX Compact. Heat Recovery Air Handling Unit. BIM & REVIT Engineering Solutions. Acoustic Testing Laboratory College of Science & Technology HANDLERS LTD AHPHX Compact Heat Recovery Air Handling Unit 1262 Acoustic Testing Laboratory College of Science & Technology BIM & REVIT Engineering Solutions The Company Air Handlers has been trading since

More information

ADJUSTABLE PERFORATED AIR SUPPLY DIFFUSER TYPE: DC560S

ADJUSTABLE PERFORATED AIR SUPPLY DIFFUSER TYPE: DC560S Adjusting options: Construction: diffuser: steel, painted white (RAL 9) deflector plate: steel painted black (RAL 95) plenum: galvanised steel sheet with side entry, insulated or non-insulated only suitable

More information

Waterside Fancoil Units

Waterside Fancoil Units side Fancoil Units Type Horizontal chassis type waterside fancoils for concealed or exposed installations for cooling, heating and fresh air supply applications Nominal sizes 60, 90, 120, 150, 180 & 205

More information

Waterside Fancoil Units

Waterside Fancoil Units side Fancoil Units Type Horizontal chassis type waterside fancoils for concealed or exposed installations side fancoil units for cooling, heating and fresh air supply applications Nominal sizes 60, 90,

More information

LINEAR SLOT DUFFUSERS

LINEAR SLOT DUFFUSERS LINEAR SLOT DUFFUSERS CE SERIES Quality and efficiency without compromise Weltech Business Centre - Ridgeway - Welwyn Garden City - Hertfordshire AL 2AA Tel: 010 12 - Fax: 010 1 2 - email sales@jprservices.co.uk

More information

SDV Vane Swirl Diffusers

SDV Vane Swirl Diffusers SDV Vane Swirl Diffusers SDVSA Square plate vane swirl diffuser (angled slot) SDVCA Circular plate vane swirl diffuser (angled slot) SDVSB Square plate vane swirl diffuser (normal slot) SDVCB Circular

More information

Anti-Ligature Grille. There s a much bigger picture to be found at Ruskin Air Management. Model AL/35 Model AL/24. range available.

Anti-Ligature Grille. There s a much bigger picture to be found at Ruskin Air Management. Model AL/35 Model AL/24. range available. June 2013 Anti-Ligature Grille Model AL/35 Model AL/24 l Cost effective l Robust construction l Supply and exhaust l Complete plenum box range available l Full range of accessories available There s a

More information

Linear Floor Grilles Models FG, F20, F25 and FRO

Linear Floor Grilles Models FG, F20, F25 and FRO April 2010 Linear Floor Grilles Linear Floor Grilles Models FG, F20, F25 and FRO Features Model FG Recessed Linear Floor Grille Model F20 and F25 Flanged Linear Floor Grille Model FRO Roll Out Floor Grille

More information

LINEAR SLOT DIFFUSERS

LINEAR SLOT DIFFUSERS LINEAR SLOT DIFFUSERS MODEL CD Weltech Business Centre - Ridgeway - Welwyn Garden City - Hertfordshire AL7 2AA Tel: 01707 871526 - Fax: 01707 871 527 - email sales@jprservices.co.uk - www.jprservices.co.uk

More information

Precision Cooling For Business-Critical Continuity. Liebert CW. System Design Manual kW, 50 & 60Hz

Precision Cooling For Business-Critical Continuity. Liebert CW. System Design Manual kW, 50 & 60Hz Precision Cooling For Business-Critical Continuity Liebert CW System Design Manual - 26-181kW, 50 & 60Hz TABLE OF CONTENTS LIEBERT CW MODEL NUMBER NOMENCLATURE....................................1 1.0

More information

AKOR-HR NEW HIGH EFFICIENCY HEAT RECOVERY UNIT. Heat Recovery AKOR-HR. Easy maintenance. EN AKOR-HR 14/1/08 13:01 Página 599

AKOR-HR NEW HIGH EFFICIENCY HEAT RECOVERY UNIT. Heat Recovery AKOR-HR. Easy maintenance. EN AKOR-HR 14/1/08 13:01 Página 599 EN 599-604 AKOR-HR 14/1/08 13:01 Página 599 HIGH EFFICIENCY HEAT RECOVERY UNIT AKOR-HR NEW Heat Recovery unit with casing manufactured from expanded polypropylene. Outlet and inlet duct conectors Ø150.

More information

Vent-Axia Roof Units Range Energy Recovery Ventilation (ERV) Range

Vent-Axia Roof Units Range Energy Recovery Ventilation (ERV) Range CI/SfB (57.7) 1st Edition from Vent-Axia Vent-Axia Roof Units Range Energy Recovery Ventilation (ERV) Range Energy Recovery Ventilation (ERV) Range Building on the success of the Sentinel Totus 2 range

More information

COLIBRI Ceiling QUICK FACTS. Square ceiling diffuser with discs for supply air

COLIBRI Ceiling QUICK FACTS. Square ceiling diffuser with discs for supply air Square ceiling diffuser with discs for supply air QUICK FACTS Adjustable discs flexible spread pattern Can be used for vertical air diffusion Swirl function Also available in the Extract air version Designed

More information

FAN POWERED SERIES FCI-600 CONSTANT VOLUME FAN TERMINAL UNIT SPECIFIABLE FEATURES

FAN POWERED SERIES FCI-600 CONSTANT VOLUME FAN TERMINAL UNIT SPECIFIABLE FEATURES FAN TERMINAL UNIT SPECIFIABLE FEATURES Galvanized steel casing, mechanically sealed for low leakage construction NEMA TYPE 1 rated hinged control enclosure with standoff to prevent penetration of casing

More information

to obtain the specified voids due

to obtain the specified voids due ARABIAN THERMAL AIRE INDUSTRIES NEW RANGE OF TESTED & CERTIFIED SOUND ATTENUATORS Arabian Thermal Aire Industries PO Box 1125, Jubail Industrial City, Saudi Arabia -319611 Tel: +966133415857 Fax: +9661334116311

More information

D2-2. Table of Contents RETROFIT/BYPASS TERMINAL UNITS

D2-2. Table of Contents RETROFIT/BYPASS TERMINAL UNITS D2 RETROFIT/YPASS TERMINA UNITS Table of Contents RETROFIT/YPASS TERMINA UNITS RVE This retrofit terminal unit is designed to convert high pressure mechanical constant volume systems to low pressure variable

More information

Innovative, High Performance, Quiet Units.

Innovative, High Performance, Quiet Units. Fan Coil Units Innovative, High Performance, Quiet Units. Technical Brochure TM AQF-A.4GB Date : January 2006 Supersedes : TM AQF-A.3GB/04.04 Quality, efficiency and reliability, built into every unit...

More information

LOW STATIC FAN COIL UNITS District Cooling Chilled Water Application

LOW STATIC FAN COIL UNITS District Cooling Chilled Water Application STATIC FAN COIL UNITS District Cooling Chilled Water Application CLASSIFIED INSULATION & FILTER MEDIA GFC LD Series Cooling Capacity Range 9,690 yo 46,064 BTU/HR (4 ROWS ) GFC-LD-TC-10-13 3 General Specifications

More information

SysCoil 2. Fan Coil Units Models SVC, SVN, SHC, SHN to 8.75kW to 4.90kW. 94 to /h

SysCoil 2. Fan Coil Units Models SVC, SVN, SHC, SHN to 8.75kW to 4.90kW. 94 to /h SysCoil Fan Coil Units Models SVC, SVN, SHC, SHN 0.79 to 8.75kW 0.49 to 4.90kW 94 to 930 3 /h SysCoil Quality, efficiency and reliability Vertical console units with cabinet, SVC type SVC vertical console

More information

High Static Fan Coil Units YDFC

High Static Fan Coil Units YDFC Static Fan Coil Units YDFC Contents contents Product information...3 Nomenclature & features...4 Features & benefits...4 Product details...5 Technical specifications...6 Unit dimensions ST type...7 Unit

More information

something new in the air Technical Bulletin

something new in the air Technical Bulletin something new in the air Technical Bulletin 2 Air Leaf 2 Air Leaf 3 Innova is a company operating in the renewable energy sector and develops advanced climatic comfort systems for every season. The technological

More information

Automatic Roof Door Vents

Automatic Roof Door Vents DATA SHEET Automatic Roof Door Vents Features n UL Listed for use as an automatic smoke vent n FM Approved as an automatic door vent for use in high expansion foam systems n Available in multiple sizes

More information

RERV & RERVX RERVLP. Rotary Energy Recovery Ventilators. Low Profile Indoor Rotary Energy Recovery Ventilators

RERV & RERVX RERVLP. Rotary Energy Recovery Ventilators. Low Profile Indoor Rotary Energy Recovery Ventilators Version: Dec. 01, 2004 RERV & RERVX Rotary Energy Recovery Ventilators Indoor and Outdoor Installations 250 20,000 CFM Capacities RERVLP Low Profile Indoor Rotary Energy Recovery Ventilators Ideal for

More information

HEAT-RECOVERY UNITS WITH ENTHALPY/ROTARY HEAT EXCHANGER TECHNICAL MANUAL

HEAT-RECOVERY UNITS WITH ENTHALPY/ROTARY HEAT EXCHANGER TECHNICAL MANUAL UT REC - R HEAT-RECOVERY UNITS WITH ENTHALPY/ROTARY HEAT EXCHANGER TECHNICAL MANUAL 1 CONTENTS GENERAL FEATURES... 3 Scope of the unit... 3 Available configurations... 3 Description of the components...

More information

Total cooling capacity kw Total heating capacity kw Features

Total cooling capacity kw Total heating capacity kw Features Room Fan Coils Idrofan Quality Management Systems 42N Total cooling capacity 0.75-6.35 kw Total heating capacity 0.60-9.50 kw The new generation 42N_S product range combines aesthetic and attractive design

More information

BRIZA EC 12 HYBRID. World s slimmest fan coil HEATING AND COOLING

BRIZA EC 12 HYBRID. World s slimmest fan coil HEATING AND COOLING World s slimmest fan coil wall and ceiling installation 2-or 4-Pipe system heating and / or cooling with or without enclosure easy installation 24VDC EC motor silent, powerful, economical, sustainable

More information

Panel Floor Grilles Model LDA, MDA, HDA, PFS and F48

Panel Floor Grilles Model LDA, MDA, HDA, PFS and F48 May 2010 Panel Floor Grilles Panel Floor Grilles Model LDA, MDA, HDA, PFS and F48 Features l Model LDA Light Duty Panel Floor Grille l Model MDA Medium Duty Panel Floor Grille l Model HDA Heavy / Extra

More information

CHILLED WATER FAN-COIL UNITS

CHILLED WATER FAN-COIL UNITS 40LM - PRODUCT DATA DIGEST CHILLED WATER FAN-COIL UNITS QUALITY SYSTEM MALAYSIA MS ISO 001 REG. NO: AR 023 1 Any room, every room flexibility in an air conditioning system FEATURES: Chilled Water Furred-in

More information

Fire Dampers. Type FDF. Compliant to SABS (193:2004) SA/6/1/EN/3

Fire Dampers. Type FDF. Compliant to SABS (193:2004) SA/6/1/EN/3 SA/6/1/EN/3 Fire Dampers Type FDF Compliant to SABS (193:2004) TROX (South Africa) (Pty) Ltd. 10 Wigford Road Masons Mill Pietermaritzburg Tel. +27 (0)33 398 1006 Fax. +27 (0)33 398 1100 email : pmb@troxsa.co.za

More information

Ceiling swirl diffusers with perforated face plate

Ceiling swirl diffusers with perforated face plate X X testregistrierung Ceiling swirl diffusers with perforated face plate Type Horizontal swirling air discharge Diffuser face plate with perforated circular face style and exposed discharge nozzle Diffuser

More information

VC Series. Volume Control Dampers M A N U F A C T U R E R S O F A I R, F I R E A N D S M O K E C O N T R O L P R O D U C T S

VC Series. Volume Control Dampers M A N U F A C T U R E R S O F A I R, F I R E A N D S M O K E C O N T R O L P R O D U C T S V41706 VC Series Volume Control Dampers Roll formed steel blades with three material options DW144 compliant Flanged models with 65mm deep mechanically fixed casings Rectangular spigotted models with 85mm

More information

Fire Block and Pressed Steel Grilles

Fire Block and Pressed Steel Grilles September 2010 Fire Block and Pressed Steel Grilles Fire Block FB60 Sodium silicate based intumescent material. Provides the lowest activation temperature of any intumescent material at degrees C. It is

More information

MANUAL INSTALLATION. Active Chilled Beam Linear. ACBL Series. v101 Issue Date: 04/10/ Price Industries Limited. All rights reserved.

MANUAL INSTALLATION. Active Chilled Beam Linear. ACBL Series. v101 Issue Date: 04/10/ Price Industries Limited. All rights reserved. MANUAL INSTALLATION Active Chilled Beam Linear ACBL Series v11 Issue Date: 4/1/18 218 Price Industries Limited. All rights reserved. TABLE OF CONTENTS Product Overview Before You Start...1 Maintenance...1

More information

The Premium Quality Fan Coil Units for Horizontal Application Hydronic or Electric Heat

The Premium Quality Fan Coil Units for Horizontal Application Hydronic or Electric Heat Producing Quality Heating & Cooling Equipment For Over 50 Years CEA SERIES CEILING EPOSED HORIZONTAL FAN COIL UNITS The Premium Quality Fan Coil Units for Horizontal Application Hydronic or Electric Heat

More information

Sidewall Propeller Fans Direct Drive. Exhaust / Supply

Sidewall Propeller Fans Direct Drive. Exhaust / Supply Sidewall Propeller Fans Direct Drive / February 2009 Sidewall Propeller Fans Greenheck s sidewall propeller fan line is the ideal choice for factory and warehouse applications where high volumes of air

More information

Fan coil unit NBS 100/150

Fan coil unit NBS 100/150 Fan coil unit /150 Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telephone +49 (0) 74 63-980 - 0 Fax +49 (0) 74 63-980 - 200 info@schako.de www.schako.de Contents Description...3 Advantages...3

More information

Actionair Smoke/Shield PTC

Actionair Smoke/Shield PTC September 2004 Smoke/Shield PTC Actionair Smoke/Shield PTC Proportional Torque Control Automatic Smoke and Fire Dampers Features and Design Guide Proportional Torque Control for optimised torque performance.

More information

Ductable water unit FWD UNT-PRC002-E4

Ductable water unit FWD UNT-PRC002-E4 Ductable water unit FWD 08-1 - 0-0 - 4 UNT-PRC00-E4 Table of Contents General data... Performance data... 4 Cooling capacities... 4 Heating capacities... Water pressure losses... 6 Available static pressure...

More information

FS Fan-Coil Units Hi-Rise, Vertical

FS Fan-Coil Units Hi-Rise, Vertical FS Fan-Coil Units Hi-Rise, Vertical FSC Concealed Dimensional Data 4-PIPE 2-PIPE TOP VIEWS Page Trims Short (5/8") Here! SIDE VIEW FRONT VIEW Dimensions Unit Size A B Single/Double Supply C D E 03 & 04

More information

Warning. Document ref: A October 2015

Warning. Document ref: A October 2015 Sentry Door Curtain Installation, Operation & Maintainance Instructions Dunham-Bush Ltd, Downley Road, Havant, Hampshire, P09 2JD Tel. 023 9247 7700 Email. info@dunham-bush.co.uk Document ref: 128-000-001-A

More information

Product Data. 35J Single-Duct Retrofit Terminal Units for Variable Air Volume Systems. 40 to 3700 cfm

Product Data. 35J Single-Duct Retrofit Terminal Units for Variable Air Volume Systems. 40 to 3700 cfm Product Data 35J Single-Duct Retrofit Terminal Units for Variable Air Volume Systems 40 to 3700 cfm The 35J retrofit terminal units offer: Unit casing of 22-gage galvanized steel construction (optional

More information

Fan coil units. HFCE, HFXE, VFCE, VFXE series Sizes 03 to to 3400 m3/h UNT-PRC007-E4

Fan coil units. HFCE, HFXE, VFCE, VFXE series Sizes 03 to to 3400 m3/h UNT-PRC007-E4 Fan coil units HFCE, HFXE, VFCE, VFXE series Sizes 03 to 20-300 to 3400 m3/h 2012 Trane Contents Features and Benefits 4 Model Nomenclature 5 Performance Data 7 Capacities 9 Dimensional data 19 Typical

More information

Fan coil units. Why choose Daikin fan coil units? 540 Products overview 542. Options & accessories 560. Round flow cassette 544 FWC-BT/BF 544

Fan coil units. Why choose Daikin fan coil units? 540 Products overview 542. Options & accessories 560. Round flow cassette 544 FWC-BT/BF 544 Fan coil units Why choose Daikin fan coil units? 540 Products overview 542 Round flow cassette 544 FWC-BT/BF 544 4-way blow ceiling mounted cassettes 545 FWG-AT/AF 545 FWF-BT/BF 546 FWF-CT 547 Floor standing

More information

Slot diffusers, Round duct diffusers. IMP Klima

Slot diffusers, Round duct diffusers. IMP Klima , Round duct diffusers 04 Round duct diffusers 176 , Round duct diffusers SLOT DIFFUSERS, ROUND DUCT DIFFUSERS SWIRL DIFFUSERS, VARIABLE SWIRL DIFFUSERS CIRCULAR DIFFUSERS, SQUARE DIFFUSERS VENTILATING

More information

Water terminals From 360 to 1598 m 3 /h. From 1.3 to 9.6 kw. SysQuare. Chilled water cassettes. From 1.1 to 14.0 kw

Water terminals From 360 to 1598 m 3 /h. From 1.3 to 9.6 kw. SysQuare. Chilled water cassettes. From 1.1 to 14.0 kw Water terminals From 360 to 1598 m 3 /h SysQuare Chilled water cassettes From 1.3 to 9.6 kw From 1.1 to 14.0 kw SysQuare The best way to combine low noise and energy savings 6 sizes (20, 30, 40, 50, 60

More information

FN Fan-Coil Units High-Performance, Horizontal

FN Fan-Coil Units High-Performance, Horizontal FN Fan-Coil Units High-Performance, Horizontal Model FNX Exposed-Cabinet Dimensional Data Notes: 1. All dimensions are in inches [mm] and are +/- 1/8" [3 mm]. Metric values are soft conversions. 2. See

More information

FAN POWERED TERMINAL UNITS

FAN POWERED TERMINAL UNITS Benefits: Fan powered terminals are typically used for heating and cooling of perimeter zones. Operating cost savings can be achieved through the use of waste heat recovery from the ceiling plenum and

More information