Table of contents. General new. New master schedule. Report on the first 5 weeks of LS2 in the PS. Works foreseen for the next 3 weeks

Size: px
Start display at page:

Download "Table of contents. General new. New master schedule. Report on the first 5 weeks of LS2 in the PS. Works foreseen for the next 3 weeks"

Transcription

1 PS Planning

2 Table of contents General new New master schedule Report on the first 5 weeks of LS2 in the PS Works foreseen for the next 3 weeks 2

3 Introduction - Organisation Activity Technical Coordinator B269 Activities Stephane Reignier B355 EPC Activities Frederic Daligault Facility Coordinator s Fernando Pedrosa David Hay (Deputy) Site Coordination Nicolas Mornand EROS Jordi Bossy Integration Jean-Pierre Corso Antoine Kosmicki Configuration / Layout DB Thomas Birtwistle Blanca Vazquez de Prada B365 TE-EPC Activities Nicolas David Main Units refurbishment Aniello Russo Facility coordination support: Nicolas Mornand Oliver Hans New BTP line Mike Hourican LINAC4 connection Simon Mataguez New F61 line Sebastien Evrard 3

4 Central ring access restrictions Issue / Possible issue Cars parked in non parking places create problems to maneuver with the transport equipment (observed already during the YETS); Big amount of activities requiring transport Suggestion Block the road GOWARD at the level of B.131 Block the 6 parking places in front of B.353 Block the 5 parking places in front of B.587 Allow the passage only for the RP team and any loading and unloading activity (transport but also others) Status: Barriers already installed, and from next Monday we will apply the restriction at the level of the route GOWARD 4

5 Central ring access restrictions Please use the fencing parking places to deliver your container and as buffer zone for nonradioactive material NOTE: as for any other buffer zone the equipment should not stay there more than 1 week 5

6 Master schedule v.1.3 Main changes with respect to the previous version: TE-EPC is trying to do what they can to have POPS ready by the 11 th May 2020, so the new schedule considers that we have 2 weeks of POPS tests and 1 week magnet tests before we close the PS SWY This translates to: PS closed for 3 weeks from the 11 th May 2020 PS SWY closed from the 11 th May 2020

7 INST. OF PALLETS PA26 cut the rails CV on-site insp. Cleaning the access points Lockouts for TE-MSC (priority to POPS + B8) INST. OF PALLETS PA26 Cut the rails Removal of the magnet covers (MUs and Aux) Installation of the EN-EL distribution boxes TT2 RP survey PS + PS SWY RP sur. Lockouts for TE-MSC (priority to POPS + B8) PA26 Cut the rails + TT2 buffer zone SMB drilling test Installation of the remote in PR219 Removal of the magnet covers (MUs and Aux) Installation of the EN-EL distribution boxes PA26 Cut the rails Installation of the remote in PR219 Removal of the magnet covers (MUs and Aux) Installation of the EN-EL distribution boxes PA26 Cut the rails Installation of the remote in PR219 Week 50 - planning Activity not performed Material left in the middle of the passage for a long period of time

8 Week 51 Remove the lockout of POPS + B8 + PFW Test N/S Recovery of the systems need for the MSC tests Issue discovered during the HV More time needed for investigation Main Units Diagnostic tests Magnet HV test Lockout POPS + B8 + PFW for LS2

9 Cabling inst. Between 245 and 269 Removal of the PS SWY magnet covers + Re-installation of the AUX magnet covers Cabling inst. Between 245 and 269 Remove the blocks on the SWY side Cabling inst. Between 245 and 269 Remove the PS SWY concrete chicane Cabling inst. Between 245 and 269 Week 2 Activities not performed Remove the lockout on the TT2 PCs MUs preparation Vent vacuum sector PR80 + remove SS73 equipment + remove SS75 Wire Scanner + Pump down KFA71 and KFA79 + Remove BLMs in MU73, MU24, MU27, MU44 and MU22 Additional Remov Magnet HV test period al to of investigate the the problem TT2 encountered during the magnet 21 st December 2018 covers tests TT2 magnet tests Lockout the TT2 PCs for LS2

10 14 th January 2019 PS SWY transfer lines magnet tests Remove the lockout for the test of the PS SWY magnets MU73 Incl. SS74 Disconnect MU73 and remove SS74 14/Jan/2019 Removal of the covers of the PS SWY transfer lines was done only this day SS75 was removed at the same time as SS73 and SS74 to allow to keep the KFA71 and KFA79 under vacuum 10

11 15th January 2019 SMH57 PS SWY transfer lines magnet tests Extract MU73 from the ring and transport to B.151 MU73 Remove SMH57 Delays to start the tests due to different reasons Technical problems with the hydraulic system and the locomotive 11

12 16th January 2019 MU73 Lockout all the PS SWY transfer line magnets for LS2 Technical problems with the hydraulic system and the locomotive Extract MU73 from the ring and transport to B.151 Disconnect MU24 and remove SS24 Remove SMH16 CV works not started due to a pending decision with integration Installation of a scaffolding for the installation of the water pipes in the SWY Disconnect the RF longitudinal damper and identification of cables for the decabling Disconnect the end of zone door New CV pipes MU24 Disc. + SS24 Remove SMH16 End zone door SS02 damper GENERAL ACCESS to the PS and TT2 Modification to the planning: Keep the SMH42 in the ring until the 21 st January 12

13 17th January 2019 MU73 in B.151 by lunch time MU27 Disc. SS27 MU24 D11/11 MU73 Extract MU73 from the ring and transport to B.151 Technical problems with the hydraulic system and the locomotive Disconnect MU27 and remove SS27 Installation of the water pipes in the SWY De-cabling (BWS)(D11/11) CV works not started Light + emergency light + sockets upgrade due to a pending 51 to 64 outer side (15 days)(o) decision with Disconnect integration the RF longitudinal damper and identification of cables for the decabling EN-EL LV consolidation not installation B Cut and remove the chamber from started MU73 in the foreseen date NO LIGHT on the outer side of the ring between SS51 and SS64 New CV pipes SS02 damper Inner side of the ring + gallery 3 and 5 close for the de-cabling NO ACCESS from B.151 PSR side 13

14 18th January 2019 MU27 Disc. SS27 MU24 New CV pipes SS02 damper D11/11 Why after the decabling campaign we still have this amount of cables identified with purple tap in the area? Extract MU24 from the ring and transport to B.151 Technical problems with the hydraulic system and the locomotive Disconnect MU27 and remove SS27 Installation of a scaffolding for the installation of the water pipes in the SWY CV works not started due to a pending De-cabling (BWS)(D11/11) Light + emergency light + sockets decision with upgrade 51 to integration 64 outer side (15 days)(o) Disconnect the RF longitudinal damper and EN-EL identification LV of cables for the decabling consolidation not started in the foreseen date installation NO LIGHT on the outer side of the ring between SS51 and SS64 Inner side of the ring + gallery 3 and 5 close for the de-cabling 14

15 PS SWY access restriction The PS SWY is closed until the 12 th February 2019 for the CV pipes installation NO other activities are authorized New CV pipes 15

16 PSR=151 and Gallery 1 access restriction Entrance through PSR=151 closed until the 15/February/20 19 Pipes Gallery 1 and part of the central ring blocked for the CV pipes 16

17 PSR=151 and Gallery 1 access restriction B.352 and outer side of the ring from SS51 to SS64 are closed until the 6/Feb/2019 for the general services consolidation 17

18 21st January 2019 Extract MU27 from the ring and transport to B.151 Disconnect MU44 and remove SS44 MU44 Disc. SS44 SMH42 MU27 Removal D11/11 Installation of the new demineralized water pipes in the PS SWY Removal of the pipes for the asbestos De-cabling (BWS)(D11/11) Light + emergency light + sockets upgrade 51 to 64 outer side (15 days)(o) installation RF water cooling manifold installation in SS91 SMH42 MU24 RF Cooling NO LIGHT on the outer side of the ring between SS51 and SS64 New CV pipes Pipes Inner side of the ring + gallery 3 and 5 close for the de-cabling PS SWY closed for the CV works Access PSR=151 closed for installation and CV works 18

19 22nd January 2019 Extract MU27 from the ring and transport to B.151 Disconnect MU44 and remove SS44 Installation of the new demineralized water pipes in the PS SWY Removal of the pipes for the asbestos MU44 Disc. SS44 MU27 Removal Pipes De-cabling (Damper)(D9/11) Light + emergency light + sockets upgrade 51 to 64 outer side (15 days)(o) installation RF water cooling manifold installation in SS91 MU24 RF Cooling New CV pipes D9/11 19

20 23nd January 2019 MU44 Removal Extract MU44 for the probe insertion Disconnect MU22 and remove SS22 Installation of the new demineralized water pipes in the PS SWY Removal of the pipes for the asbestos Light + emergency light + sockets upgrade 51 to 64 outer side (15 days)(o) installation Pipes RF water cooling manifold installation in SS91 MU22 Disc. SS22 RF Cooling New CV pipes 20

21 24th January 2019 MU44 Removal Extract MU44 for the probe insertion Disconnect MU22 and remove SS22 Installation of the new demineralized water pipes in the PS SWY Removal of the pipes for the asbestos Light + emergency light + sockets upgrade 51 to 64 outer side (15 days)(o) installation Pipes RF water cooling manifold installation in SS96 MU22 Disc. SS22 New CV pipes RF Cooling 21

22 Ring restrictions KFA45 test KFA45 test Ring closed from SS42 to SS47 due to the KFA45 tests Restriction from the 25 to the 28/Jan/

23 25th January 2019 Extract MU22 from the ring and transport to B.151 Disconnect MU29 and remove SS29 Installation of the new demineralized water pipes in the PS SWY Removal of the pipes for the asbestos KFA45 test Light + emergency light + sockets upgrade 51 to 64 outer side (15 days)(o) MU29 dis. + SS29 Pipes installation RF water cooling manifold installation in SS96 Test the existing KFA45 before MU22 New CV pipes RF Cooling 23

24 28th January 2019 Extract MU22 from the ring and transport to B.151 Disconnect MU29 and remove SS29 Installation of the new demineralized water pipes in the PS SWY Removal of the pipes for the asbestos KFA45 test Light + emergency light + sockets upgrade 51 to 64 outer side (15 days)(o) installation MU29 dis. + SS29 Pipes C11/23 RF water cooling manifold installation in SS96 Test the existing KFA45 before Cabling (C11/23) New CV pipes MU22 RF Cooling Outer side of the ring closed for the cabling campaign between SS02 and SS67 24

25 29th January 2019 Extract MU29 from the ring and transport to B.151 Installation of the new demineralized water pipes in the PS SWY Removal of the pipes for the asbestos Light + emergency light + sockets upgrade 51 to 64 outer side (15 days)(o) installation MU29 Pipes C11/23 RF water cooling manifold installation in SS11 Cabling (C11/23) Outer side of the ring closed for the cabling campaign between SS02 and SS67 New CV pipes RF Cooling 25

26 30th January 2019 Extract MU29 from the ring and transport to B.151 Installation of the new demineralized water pipes in the PS SWY Removal of the pipes for the asbestos MU29 Pipes Light + emergency light + sockets upgrade 51 to 64 outer side (15 days)(o) installation RF water cooling manifold installation in SS11 Cabling (C11/23) C11/23 Outer side of the ring closed for the cabling campaign between SS02 and SS67 New CV pipes RF Cooling 26

27 31th January 2019 Remove KFA45 Remove KFA45 and SMH31 Installation of the new demineralized water pipes in the PS SWY Removal of the pipes for the asbestos Light + emergency light + sockets upgrade 51 to 64 outer side (15 days)(o) installation RF water cooling manifold installation in SS11 Remove SMH31 Sector door Pipes Cabling (C11/23) C11/23 Outer side of the ring closed for the cabling campaign between SS02 and SS67 New CV pipes RF Cooling 27

28 1st February 2019 Remove KFA45 Remove the KFA45 Installation of the new demineralized water pipes in the PS SWY Removal of the pipes for the asbestos Light + emergency light + sockets upgrade 51 to 64 outer side (15 days)(o) installation RF water cooling manifold installation in SS11 Sector door Pipes Cabling (C11/23) C11/23 Outer side of the ring closed for the cabling campaign between SS02 and SS67 New CV pipes RF Cooling 28

29 Remove the KFA45 4th February 2019 Installation of the new demineralized water pipes in the PS SWY RF Cooling Remove KFA45 Asbestos + false floor opening Light + emergency light + sockets upgrade 51 to 64 outer side (15 days)(o) installation RF water cooling manifold installation in SS36 Cabling (C9/23) Asbestos + False floor opening in the central ring Outer side of the ring closed for the cabling campaign between SS02 and SS67 New CV pipes C9/23 Same restrictions in gallery 1 + PSR access + central ring as for the pipes 29

30 Remove the KFA45 5th February 2019 Installation of the new demineralized water pipes in the PS SWY RF Cooling Remove KFA45 Asbestos + false floor opening Light + emergency light + sockets upgrade 51 to 64 outer side (15 days)(o) installation RF water cooling manifold installation in SS36 Cabling (C9/23) Asbestos + False floor opening in the central ring Outer side of the ring closed for the cabling campaign between SS02 and SS67 New CV pipes C9/23 Same restrictions in gallery 1 + PSR access + central ring as for the pipes 30

31 Remove the KFA45 6th February 2019 Installation of the new demineralized water pipes in the PS SWY RF Cooling Remove KFA45 Asbestos + false floor opening Light + emergency light + sockets upgrade 51 to 64 outer side (15 days)(o) installation RF water cooling manifold installation in SS46 Cabling (C9/23) Asbestos + False floor opening in the central ring No access in the area affected by the cabling New CV pipes C9/23 Same restrictions in gallery 1 + PSR access + central ring as for the pipes 31

32 7th February 2019 RF Cooling MU32 Dis. + SS33 Asbestos + false floor opening MU73 Incl. SS74 reinstallation MU73 re-installation + SS74 Disconnect MU32 and remove SS33 Installation of the new demineralized water pipes in the PS SWY Light + emergency light + sockets upgrade 64 to 76 outer side (15 days)(o) installation RF water cooling manifold installation in SS46 Cabling (C9/23) Asbestos + False floor opening in the central ring No access in the area affected by the cabling New CV pipes C9/23 No access to the outer side of the ring between SS64 and SS76 Same restrictions in gallery 1 + PSR access + central ring as for the pipes 32

33 8th February 2019 RF Cooling MU32 Dis. + SS33 Asbestos + false floor opening MU73 Incl. SS74 reinstallation MU73 re-installation + SS74 Disconnect MU32 and remove SS33 Installation of the new demineralized water pipes in the PS SWY Light + emergency light + sockets upgrade 64 to 76 outer side (15 days)(o) installation RF water cooling manifold installation in SS46 Cabling (C9/23) Asbestos + False floor opening in the central ring No access in the area affected by the cabling New CV pipes C9/23 No access to the outer side of the ring between SS64 and SS76 Same restrictions in gallery 1 + PSR access + central ring as for the pipes 33

34 11th February 2019 RF Cooling MU73 connection MU32 Installation of the new demineralized water pipes in the PS SWY BTP dis. Asbestos + false floor opening MU73 connection Light + emergency light + sockets upgrade 64 to 76 outer side (15 days)(o) installation RF water cooling manifold installation in SS51 MU32 Cabling (C9/23) New CV pipes C9/23 Asbestos + False floor opening in the central ring BTP equipment disconnection No access in the area affected by the cabling No access to the outer side of the ring between SS64 and SS76 Same restrictions in gallery 1 + PSR access + central ring as for the pipes 34

35 12th February 2019 RF Cooling MU73 connection MU32 Installation of the new demineralized water pipes in the PS SWY BTP dis. Asbestos + false floor opening MU73 connection Light + emergency light + sockets upgrade 64 to 76 outer side (15 days)(o) installation RF water cooling manifold installation in SS51 MU32 Cabling (C9/23) New CV pipes C9/23 Asbestos + False floor opening in the central ring BTP equipment disconnection No access in the area affected by the cabling No access to the outer side of the ring between SS64 and SS76 Same restrictions in gallery 1 + PSR access + central ring as for the pipes 35

36 13th February 2019 RF Cooling MU24 re-installation + SS24 Disconnect MU13 and remove SS14 Light + emergency light + sockets upgrade 64 to 76 outer side (15 days)(o) BTP dis. Asbestos + false floor opening installation RF water cooling manifold installation in SS51 Cabling (C9/23) Asbestos + False floor opening in the central ring MU24 Incl. SS24 reinstallation BTP equipment disconnection No access in the area affected by the cabling MU13 dis. + SS14 C9/20 No access to the outer side of the ring between SS64 and SS76 Same restrictions in gallery 1 + PSR access + central ring as for the pipes 36

37 14th February 2019 RF Cooling MU24 re-installation + SS24 Disconnect MU13 and remove SS14 Light + emergency light + sockets upgrade 64 to 76 outer side (15 days)(o) BTP dis. Asbestos + false floor opening installation RF water cooling manifold installation in SS56 Cabling (C9/23) Asbestos + False floor opening in the central ring MU24 Incl. SS24 reinstallation BTP equipment disconnection No access in the area affected by the cabling MU13 dis. + SS14 C9/20 No access to the outer side of the ring between SS64 and SS76 Same restrictions in gallery 1 + PSR access + central ring as for the pipes 37

38 15th February 2019 BTP dis. RF Cooling MU24 connection MU13 Light + emergency light + sockets upgrade 64 to 76 outer side (15 days)(o) installation RF water cooling manifold installation in SS56 MU24 Connectio n Cabling (C9/23) Asbestos + False floor opening in the central ring BTP equipment disconnection No access in the area affected by the cabling MU13 C9/20 No access to the outer side of the ring between SS64 and SS76 Same restrictions in gallery 1 + PSR access + central ring as for the pipes 38

39 TT2 Report Temporary buffer zone created Line is still under vacuum BTV cameras removed Ventilation units maintenance Coming activities Drilling between TT2 and the PS SWY (29/Jan to 26/Feb)

40 B.151 Report All magnet covers in the PS bridge MU73 in the magnet workshop MU24 in the vacuum workshop MU27 ready to be transferred to B.150 Coming activities Main Units work

41 B.255 CV dismantling work ongoing

42 B.269 Report Disconnection and cable identification ongoing Cabling campaign for the smoke detection performed in the slot foreseen Coming activities Disconnection until end of January (up to 30/Jan/2019) Smoke detection (31/Jan/2019) Outside transformers (4/Feb/2019) Internal structure dismantling (1/Feb/2019 to the 19/Feb/2019)

43 B.355 Report Some cable pulling between the new switch room and the ring are ongoing Coming activities Disconnection until February (up to 5/Feb/2019) Power converters (31/Jan to 4/Feb/2019) Installation of the new water pipes for the TFB racks and the new power converters (5/Feb to 01/Mar)

44 B.359 Report RF tests ongoing?? Coming activities Cabling campaign for the EN-EL controls (last minute request)

45 B.362 Report KFA28 equipment ongoing Coming activities

46 B.365 Report Works not started Coming activities Disconnection and cables identification

47 Question? 47

Integration issues in the tunnel and Impact on general LHC systems

Integration issues in the tunnel and Impact on general LHC systems 28 January 2010 1 LHC Performance workshop Chamonix 2010 Integration issues in the tunnel and Impact on general LHC systems Space requirements Radiation levels Existing/missing infrastructure and associated

More information

Fixing the Line s Canarsie Tunnel. Manhattan CB6 11/5/2018

Fixing the Line s Canarsie Tunnel. Manhattan CB6 11/5/2018 Fixing the Line s Canarsie Tunnel Manhattan CB6 11/5/2018 Interborough Bus Service 80+ buses in the peak hour in the peak direction over the Williamsburg Bridge Projected to carry 17% of riders 1 Bus Priority

More information

September 2008 TEC, INTELLIGENT MONITORING SYSTEM

September 2008 TEC, INTELLIGENT MONITORING SYSTEM September 2008 TEC, INTELLIGENT MONITORING SYSTEM ABB BU Transformers - 1-10/9/2008 TEC, philosophy ABB BU Transformers - 2 - TEC was launched by ABB in year 2002 to improve transformers performance. More

More information

ILC. CFS update for Europe (CERN): Cross Sections 3d Layout and BDS tunnel diameters CERN Resources. LCWS10 and ILC10 - Beijing

ILC. CFS update for Europe (CERN): Cross Sections 3d Layout and BDS tunnel diameters CERN Resources. LCWS10 and ILC10 - Beijing ILC CFS update for Europe (CERN): Cross Sections 3d Layout and BDS tunnel diameters CERN Resources John Osborne March 2010 LCWS10 and ILC10 - Beijing Cross section for Europe (CERN) 5.2m diameter for Kly

More information

PETRA III Damping Sections

PETRA III Damping Sections PETRA III Damping Sections Markus Tischer, HASYLAB 05.05.06 Damping wiggler sections BINP / DESY cooperation on Damping wiggler Vacuum system Absorber M. Tischer PETRA III Damping Sections (MAC meeting,

More information

Mobile Diesel Heaters GRY-D / GRY-I Service Training Course

Mobile Diesel Heaters GRY-D / GRY-I Service Training Course Mobile Diesel Heaters GRY-D / GRY-I Service Training Course 1 Rev. No. 3 January 24, 2011 GRY-I Indirect-fired Diesel Heaters GRY-I 15 WU GRYP 50 AP GRY-I 25 WU GRYP 90 AP GRY-I 40 WU GRYP 135 AP 2 GRY-D

More information

Commuter Rail Performance. October

Commuter Rail Performance. October Commuter Rail Performance October 31 2016 1 Background - overall performance Year To Date: 89.67% YTD 125,629 trains North: 90.79% YTD 48,426 trains South: 89.07% YTD 77,203 trains 2 Background - overall

More information

Digitrip Retrofit System for ITE K-3000, K-3000 S, K-4000 and K-4000 S Breakers

Digitrip Retrofit System for ITE K-3000, K-3000 S, K-4000 and K-4000 S Breakers Supersedes IL 33-858-4 Dated 05/02 Digitrip Retrofit System for ITE K-3000, K-3000 S, K-4000 and K-4000 S Breakers Digitrip Retrofit System for ITE K-3000, Digitrip Retrofit System for ITE K-3000, K-3000

More information

Inventory Levels - All Prices. Inventory Levels - By Price Range

Inventory Levels - All Prices. Inventory Levels - By Price Range Inventory Levels - All Prices Idaho Falls Bonneville Total 3-Mar-17 152 108 260 2-Mar-18 109 78 187-28% Inventory Levels - By Price Range 3-Mar-17 2-Mar-18 0-100,000 41 6 100,001-125,000 19 8 125,001-150,000

More information

Build a Simple Handheld Throttle for the Digitrax Zephyr

Build a Simple Handheld Throttle for the Digitrax Zephyr Build a Simple Handheld Throttle for the Digitrax Zephyr Here is a way to build a simple three button throttle for use with the Digitrax popular Zephyr. This handheld throttle is designed work with the

More information

WARNING. Murphy W-Series Engine Panels General Installation Instructions. Installation Accessories

WARNING. Murphy W-Series Engine Panels General Installation Instructions. Installation Accessories Murphy W-Series Engine Panels General Installation Instructions WS-93002N Revised 04-06 Section 30 (00-02-0191) Read the following information before installing. These installation instructions are typical

More information

South Gloucestershire Challenge Fund and Cycle Ambition Fund

South Gloucestershire Challenge Fund and Cycle Ambition Fund South Gloucestershire Challenge Fund and Cycle Ambition Fund The Challenge Fund A4174 scheme is coordinated and delivered by South Gloucestershire Council who were awarded 14 million pounds from the Department

More information

WARNING. Murphy W-Series Engine Panels General Installation Instructions. Installation Accessories

WARNING. Murphy W-Series Engine Panels General Installation Instructions. Installation Accessories Murphy W-Series Engine Panels General Installation Instructions WS-93002N Revised 08-02 Section 30 (00-02-0191) Read the following information before installing. These installation instructions are typical

More information

Scope and results of hardware commissioning to 3.5 TeV and lessons learnt

Scope and results of hardware commissioning to 3.5 TeV and lessons learnt Scope and results of hardware commissioning to 3.5 TeV and lessons learnt Preconditions for operating at 5 TeV in 2010 Session 1-25 th January 2010 M.Solfaroli BE/OP Contents Commissioning to 1.18TeV Efficiency

More information

Purple Line Extension Updates on La Cienega and Rodeo Stations December 13, 2017

Purple Line Extension Updates on La Cienega and Rodeo Stations December 13, 2017 Purple Line Extension Updates on La Cienega and Rodeo Stations December 13, 2017 1 Agenda Project Overview Section 1 Construction Updates Wilshire/La Cienega Station La Cienega Decking Decking Overview

More information

CATALOG OF REPLACEMENT PARTS

CATALOG OF REPLACEMENT PARTS CATALOG OF REPLACEMENT PARTS VC4G & VC6G GAS CONVECTION OVENS VULCAN-HART DIVISION OF ITW FOOD EQUIPMENT GROUP, LLC 3600 NORTH POINT BLVD., BALTIMORE, MD 21222 FORM 43031 Rev. L (January 2018) F-43031

More information

POLARSTART PS-3025 SH Multi-Channel Remote Starter System for AUTOMATIC Transmissions

POLARSTART PS-3025 SH Multi-Channel Remote Starter System for AUTOMATIC Transmissions POLARSTART PS-3025 SH Multi-Channel Remote Starter System for AUTOMATIC Transmissions USER GUIDE INTRODUCTION...2 BASIC REMOTE OPERATION...2 REMOTE-STARTING YOUR VEHICLE...2 DRIVING OFF...2 IDLE MODE...2

More information

Status of the DARHT 2 nd Axis Accelerator at Los Alamos National Laboratory

Status of the DARHT 2 nd Axis Accelerator at Los Alamos National Laboratory Status of the DARHT 2 nd Axis Accelerator at Los Alamos National Laboratory R.D. Scarpetti, S. Nath, J. Barraza, C. A. Ekdahl, E. Jacquez, K. Nielsen, J. Seitz Los Alamos National Laboratory, Los Alamos,

More information

WESCO INDUSTRIAL PRODUCTS, INC. Heavy Duty Semi Electric Pallet Truck. Part Number:

WESCO INDUSTRIAL PRODUCTS, INC. Heavy Duty Semi Electric Pallet Truck. Part Number: WESCO INDUSTRIAL PRODUCTS, INC Heavy Duty Semi Electric Pallet Truck Part Number: 273289 Note: Operator MUST read and understand these operating instructions before using this Hand Pallet Truck. Table

More information

Fuel Management in EWN

Fuel Management in EWN Fuel Management in EWN Fuel Management in EWN Dr. Helmut Förtsch, EWN GmbH Eberhard Thurow, EWN GmbH Fuel Management in EWN Part 1: Status in 1990 Part 2: Spent nuclear fuel strategy of EWN Part 3: Technical

More information

Artesis MCM Case Studies. March 2011

Artesis MCM Case Studies. March 2011 Artesis MCM Case Studies March 2011 Case 1 Automotive Company: Automobile Manufacturer A Equipment: Pump Stator Isolation Breakdown Decreasing current unbalance level Case 1 Automotive Company: Automobile

More information

Engine Dismantle and Assemble ( )

Engine Dismantle and Assemble ( ) Engine Dismantle and Assemble ( 34 8) Special Tools 5 053 Slide hammer 47 Vibration damper remover 47 5053 00 Splined head socket, cylinder head bolts 87 Mounting stand with geared drive 00 059C Installer

More information

Horseshoe Bay Terminal Open House

Horseshoe Bay Terminal Open House Horseshoe Bay Terminal Open House July 5, 2007 Welcome Aboard The purpose of this Open House is to provide you with information and to receive your input for consideration on the Horseshoe Bay Terminal

More information

PELICAN Ceiling HF. Square extract air diffuser QUICK FACTS

PELICAN Ceiling HF. Square extract air diffuser QUICK FACTS Square extract air diffuser QUICK FACTS Perforated air diffuser front face Manages large extract airflows Flush design Designed for modular suspended ceilings Quick Access front face Can be combined with

More information

Product manual Extraction arm KUA

Product manual Extraction arm KUA Product manual Extraction arm KUA Table of contents: Page: Technical description...2 Delivery...2 Advantages...2 Technical data...2 Components and operation...2 Handling...2 Hood operation...2 Mounting

More information

Toll Free Phone, (US & Canada): (800) Toll Free Fax, (US & Canada): (800)

Toll Free Phone, (US & Canada): (800) Toll Free Fax, (US & Canada): (800) Toll Free Phone, (US & Canada): (800) 427-6668 Toll Free Fax, (US & Canada): (800) 361-7745 http://www.garland-group.com MODEL: MCO-GS/GD-10 MU - CE UNITS Oven Manufactured Up To May 29, 2008 DESCRIPTION

More information

The Life of a Lifter, Part 2

The Life of a Lifter, Part 2 Basics Series: The Life of a Lifter, Part 2 -Greg McConiga Last time we looked at some complicated dynamics and compared flats to rollers. Now for the hands-on. 6 FEATURE This off-the-shelf hydraulic lifter

More information

The Status of SSRF Survey and Alignment System. ChenghaoYu, Hanwen Du Lixin Yin

The Status of SSRF Survey and Alignment System. ChenghaoYu, Hanwen Du Lixin Yin The Status of SSRF Survey and Alignment System ChenghaoYu, Hanwen Du Lixin Yin Content I. Introduction II. Design of SSRF survey and alignment system III. Implementation Introduction Shanghai Synchrotron

More information

TECHNICAL SERVICE BULLETIN

TECHNICAL SERVICE BULLETIN TECHNICAL SERVICE BULLETIN To: Minuteman Dealers and Customers From: Minuteman Technical Support Date: 1/12/2011 Subject: TSB for the KIT # K-FRSPEEDSWT. For the FR17115, FR17220, FR20115 and FR20220 models.

More information

Implementation of Safety Initiatives

Implementation of Safety Initiatives Klipspruit Dragline Refurbishment Implementation of Safety Initiatives Vernon Carter Section Engineer, BHPBilliton Klipspruit Colliery 21 January 2009 Contents / Dragline History / Shutdown Statistics

More information

AUDI UK - Mandatory Workshop Equipment List - From March 31st 2012

AUDI UK - Mandatory Workshop Equipment List - From March 31st 2012 From arch 31st 2012 : Diagnostic machines -1 per 3 techs (excluding apprentices), VAS 5051B or VAS 5052A / VAS 6150 plus a VAS 6356 Test Box Wing Front Protectors, Steering Wheel Seat Covers - 1 per 1

More information

CATALOG OF REPLACEMENT PARTS

CATALOG OF REPLACEMENT PARTS CATALOG OF REPLACEMENT PARTS GAS CONVECTION OVEN SG4 ML-126610 SG6 ML-126612 VULCAN-HART DIVISION OF ITW FOOD EQUIPMENT GROUP, LLC 3600 NORTH POINT BLVD., BALTIMORE, MD 21222 FORM 45395 Rev. D (June 2017)

More information

PS24/AC Volt AC 16 Amp

PS24/AC Volt AC 16 Amp ALTERNATING CURRENT POWER SUPPLY PS24/AC-6 24 Volt AC 6 Amp FEATURES: Mains Fail Relay Output and Indicator. Fuse blow indication and relay output. 6 fused outlets DESCRIPTION: SPECIFICATIONS: Inputs Voltage-

More information

Science Applications International Corporation

Science Applications International Corporation February 7, 2011 Ms. Sharon R. Fisher 1425 Eden Road York, PA 17402 Re: 2010 Summary of Operation for North Building 4 Soil Vapor Extraction System SAIC Project 4501020172 / 5000 / 100 Dear Sharon: Science

More information

Public Meeting: Metropolitan Washington Airports Authority (MWAA) TNC (Transportation Network Company) Lot on S. Eads Street

Public Meeting: Metropolitan Washington Airports Authority (MWAA) TNC (Transportation Network Company) Lot on S. Eads Street Public Meeting: Metropolitan Washington Airports Authority (MWAA) TNC (Transportation Network Company) Lot on S. Eads Street Department of Environmental Services, Transportation Division Sept. 27, 2018

More information

A manufacturer s view of bushing reliability, testing and analysis. Lars Jonsson Håkan Rudegard

A manufacturer s view of bushing reliability, testing and analysis. Lars Jonsson Håkan Rudegard A manufacturer s view of bushing reliability, testing and analysis By Lars Jonsson Håkan Rudegard 1 A manufacturer s view of bushing reliability, testing and analysis Lars Jonsson Håkan Rudegard ABB Sweden

More information

CATALOG OF REPLACEMENT PARTS GAS CONVECTION OVENS MODELS

CATALOG OF REPLACEMENT PARTS GAS CONVECTION OVENS MODELS CATALOG OF REPLACEMENT PARTS GAS CONVECTION OVENS MODELS VC4GS VC4GD VC4GC VC6GS VC6GD VC6GC ML-126610 ML-126611 ML-136494 ML-126612 ML-126613 ML-136495 For additional information on Vulcan-Hart or to

More information

ADAPTTM. Sphere. Active communicative, supply air diffuser for the WISE system. Quick Selection

ADAPTTM. Sphere. Active communicative, supply air diffuser for the WISE system. Quick Selection ADAPTTM Sphere Active communicative, supply air diffuser for the WISE system Quick facts Supply air diffuser with an active damper Pressure-dependent and cleanable Integrated sensor module Simple wiring,

More information

TECHNICAL SUPPORT AND CONTACT US

TECHNICAL SUPPORT AND CONTACT US EXHAUST GAS TEMPERATURE SAFETY SWITCH (U.S. patent pending 60/865,147) Congratulations, you have just purchased the world s only exhaust gas temperature safety switch from a leader in high performance

More information

AUTOMATIC PARKING SYSTEMS

AUTOMATIC PARKING SYSTEMS AUTOMATIC PARKING SYSTEMS Find your Solution! CARS ARE FIRST PLACED ONTO MOTORISED MONODIRECTIONAL OR BI-DIRECTIONAL PLATFORMS AND THEN TRANSFERRED TO THE NEAREST AVAILABLE PARKING SPACE. LIFTING SYSTEMS

More information

STI Supply air valve. Specifications. Quick Selection. Product code example Supply air valve STI-160-C

STI Supply air valve. Specifications. Quick Selection. Product code example Supply air valve STI-160-C STI Supply air valve STI supply air valve for wall mounting covers a wide air volume area from 5 to 70 l/s, for duct sizes 100-200 mm. The valve can be quickly installed directly into the duct without

More information

MAKE OF AUTOMOBILE: MODEL YEAR: 2010 SYSTEM APPROVAL NUMBER ( R115 ) BOOT SET NUMBER 947/

MAKE OF AUTOMOBILE: MODEL YEAR: 2010 SYSTEM APPROVAL NUMBER ( R115 ) BOOT SET NUMBER 947/ MAKE OF AUTOMOBILE: FORD TYPE: MONDEO TANK CAPACITY: 61 Liter WvM toroidal TANK LOCATION SPARE WHEEL ROOM MODEL YEAR: 2010 SYSTEM APPROVAL NUMBER ( R115 ) R115-0000** BOOT SET NUMBER 947/1810501 NUMBER:

More information

FALCON Ceiling. Circular ceiling air diffuser for supply air QUICK FACTS

FALCON Ceiling. Circular ceiling air diffuser for supply air QUICK FACTS Circular ceiling air diffuser for supply air QUICK FACTS Manages large supply airflows Horizontal or vertical distribution pattern Provision for motorised adjustment of the distribution pattern Suitable

More information

Service Bulletin 1988 PRELUDE. RECALL: 1988 Prelude Power Steering Supply Hose

Service Bulletin 1988 PRELUDE. RECALL: 1988 Prelude Power Steering Supply Hose Service Bulletin Model Applicable To File Under Bulletin No. 1988 PRELUDE See VEHICLES AFFECTED ENGINE 88-014 Issue Date APRIL 20, 1988 RECALL: 1988 Prelude Power Steering Supply Hose PROBLEM When subjected

More information

Technical Specifications (In-Cash Procurement)

Technical Specifications (In-Cash Procurement) IDM UID VLHSLE VERSION CREATED ON / VERSION / STATUS 12 Feb 2018 / 1.2 / Approved EXTERNAL REFERENCE / VERSION Technical Specifications (In-Cash Procurement) Technical Summary for BOP-Group 6 Installation

More information

Sheet metal work. Mechanisms and accessories

Sheet metal work. Mechanisms and accessories Sheet metal work GENERAL LOWER STRUCTURE UPPER SIDE STRUCTURE UPPER REAR STRUCTURE TOP OF BODY Mechanisms and accessories EXTERIOR PROTECTION JE0 AL - JE0 EL - JE0 HL 77 11 196 742 DECEMBER 1997 Edition

More information

CATALOG OF REPLACEMENT PARTS

CATALOG OF REPLACEMENT PARTS CATALOG OF REPLACEMENT PARTS GAS CONVECTION OVENS DGC5 HGC5 HGC5D HGC5X HGC5DX ML-126614 ML-126615 ML-126616 ML-126618 ML-126619 A product of HOBART 701 S. RIDGE AVENUE TROY, OHIO 45374-0001 FORM 34608

More information

Collision Analysis Safety Tables

Collision Analysis Safety Tables Crash Severity Geography of Geography of Time and Date of Crash Conditions Features Features.. Queries Selected: Town(Hartford), Date(Year:All or //05 to 9/7/06), Severity(All), Route Class(Interstate),

More information

Pneumatic actuator. Inspired By Challenge

Pneumatic actuator. Inspired By Challenge Inspired By Challenge Actuation COMPACT actuator ESD system Interfaces Ordering code system Introduction Proven advantage The COMPACT actuator is a quarter-turn rack & pinion pneumatic actuator that doubles

More information

Study of the impact of the remote alignment in the vacuum system

Study of the impact of the remote alignment in the vacuum system Study of the impact of the remote alignment in the vacuum system R. Rego, V. Baglin, J. Hansen CERN, 24 th September 2018 EDMS: 2027649 Outline 1. Introduction 2. Inner triplet area 3. TAXN-D2 area 4.

More information

Tip: Liliput S LED Light for Forward Cabin Locomotive Date:

Tip: Liliput S LED Light for Forward Cabin Locomotive Date: Hi All, I obtained this Liliput locomotive catalogue number L131541-S some time ago and was disappointed that the feature of a steam locomotive with a forward driving cabin didn t have a detailed cabin

More information

Vacuum pumps for the ESRF EBS project Michael Hahn

Vacuum pumps for the ESRF EBS project Michael Hahn 3 rd Rencontres Nationales DU RESEAU TECHNOLOGIES DU VIDE SEVRIER, 10 13 October 2016 Vacuum pumps for the ESRF EBS project Michael Hahn On behalf of the EBS Accelerator Project Team OUTLINE Project definition

More information

Instruments. Instrument layout CHAPTER 19

Instruments. Instrument layout CHAPTER 19 CHAPTER 19 Instruments Instrument layout The dash will come with a carbon fiber insert for the instruments. It is best to start by making a template for the gauge locations. One method is to make a template

More information

Installing a CTS CDS 4.8 into a Chevy Van

Installing a CTS CDS 4.8 into a Chevy Van INSTLLTION PROCUR Installing a CTS CS 4.8 into a Chevy Van Part Numbers ffected: Various ate Changes Take ffect: ugust 2010 ***COMPLTLY R LL INSTRUCTIONS BFOR STRTING INSTLLTION!*** The following is a

More information

CEN TC256 WG01 PROGRESS: SHARING LATEST PROGRESS ON THE WORK DONE BY CEN TC256 WG01 ON THE EUROPEAN STANDARD EN45545

CEN TC256 WG01 PROGRESS: SHARING LATEST PROGRESS ON THE WORK DONE BY CEN TC256 WG01 ON THE EUROPEAN STANDARD EN45545 CEN TC256 WG01 PROGRESS: SHARING LATEST PROGRESS ON THE WORK DONE BY CEN TC256 WG01 ON THE EUROPEAN STANDARD EN45545 IV INTERNATIONAL CONFERENCE MODERN TRENDS OF FIRE PROTECTION IN ROLLING STOCK WARSAW

More information

PARTS LIST. Toll Free Phone, (US & Canada): (800) Toll Free Fax, (US & Canada): (800)

PARTS LIST. Toll Free Phone, (US & Canada): (800) Toll Free Fax, (US & Canada): (800) 1/2 SIZE CONVECTION TJ CINNAMON MCO-E-5 PARTS LIST Toll Free Phone, (US & Canada): (800) 427-6668 Toll Free Fax, (US & Canada): (800) 361-7745 http://www.garland-group.com TJ Cinnamon Oven (Rev 01) Page

More information

Illustrated Parts & Packing List & Instructions 815 Rice Lake Street, Owatonna, MN 55060

Illustrated Parts & Packing List & Instructions 815 Rice Lake Street, Owatonna, MN 55060 Illustrated Parts & Packing List & Instructions 815 Rice Lake Street, Owatonna, MN 55060 Great Plains Part #891-622C (Gandy Part #6245DS-TT) Great Plains Turbo-Till & Turbo-Chopper 2400/3000 Models 45

More information

Purple Line Extension Section 1 Construction Community Meeting January 17, 2019

Purple Line Extension Section 1 Construction Community Meeting January 17, 2019 Purple Line Extension Section 1 Construction Community Meeting January 17, 2019 1 Agenda Section 1 MOW 64 Facility Project Construction Updates: Fossils Project-wide Tunneling Wilshire/Western Wilshire/La

More information

ADAPTTM. Free. Active communicative, supply air diffuser for the WISE system, ADAPT F

ADAPTTM. Free. Active communicative, supply air diffuser for the WISE system, ADAPT F ADAPTTM Free Active communicative, supply air diffuser for the WISE system, ADAPT F Quick facts Supply air diffuser with an active damper Pressure-dependent and cleanable Integrated sensor module Simple

More information

PELICAN Ceiling. Square ceiling air diffuser for supply air and extract air QUICK FACTS

PELICAN Ceiling. Square ceiling air diffuser for supply air and extract air QUICK FACTS Square ceiling air diffuser for supply air and extract air QUICK FACTS Flexible distribution pattern, yet the acoustic data remains the same One K-factor regardless of distribution pattern Designed for

More information

On Board Diagnostics II A PCED

On Board Diagnostics II A PCED Page 1 of 8 HX18 DTC P0446 OR P1450: CHECK FOR VISUAL CAUSES OF EXCESSIVE FUEL TANK VACUUM Continuous Memory Diagnostic Trouble Code (DTC) P0446 or P1450 indicates that Self-Test has detected the Evaporative

More information

Installation Instructions

Installation Instructions Installation Instructions Seal Gard Flowmeter TM Unitized construction Plug resistant float design Tamper resistant valve design Pressure gauge standard Check valve standard 0-20 gph or 0-40 gph standard

More information

SAB 202 Screw compressor units. S pa re parts m an ual

SAB 202 Screw compressor units. S pa re parts m an ual SAB 202 Screw compressor units S pa re parts m an ual en 1 Spare parts list for SAB 202 Pos Designation No Part no Complete compressor LF, aut Vi 4161059 Complete compressor LF, man Vi 4161060 Complete

More information

Engine mechanics. Crankcase ventilation outlet

Engine mechanics. Crankcase ventilation outlet Engine mechanics Crankcase ventilation outlet The gases are drawn out of the crankcase by the vacuum in the intake manifold. The oil is separated from the gases in the labyrinth and in the cyclone oil

More information

Withdrawn Document Uncontrolled When Printed. SP (issue 1).qxd 16/4/03 1:04 pm Page 1. Module SP. GE/RT SP Rule Book. Speeds. Issue 1.

Withdrawn Document Uncontrolled When Printed. SP (issue 1).qxd 16/4/03 1:04 pm Page 1. Module SP. GE/RT SP Rule Book. Speeds. Issue 1. SP (issue 1).qxd 16/4/03 1:04 pm Page 1 GE/RT8000 - SP Rule Book Module SP Speeds Issue 1 June 2003 Comes into force 6 December 2003 SP (issue 1).qxd 16/4/03 1:04 pm Page 2 Issue Date Comments Comes into

More information

SECTION D Engine 6.0L Diesel

SECTION D Engine 6.0L Diesel 303-01D-i Engine 6.0L Diesel 303-01D-i SECTION 303-01D Engine 6.0L Diesel CONTENTS PAGE DESCRIPTION AND OPERATION Engine... 303-01D-2 303-01D-2 Engine 6.0L Diesel 303-01D-2 DESCRIPTION AND OPERATION Engine

More information

CCE - Adaptable active chilled beam for exposed installation. Halton CCE. Adaptable active chilled beam for exposed installation

CCE - Adaptable active chilled beam for exposed installation. Halton CCE. Adaptable active chilled beam for exposed installation Halton CCE Adaptable active chilled beam for exposed installation Combined cooling, heating, and supply air unit for exposed installation Ideal solution for applications where good indoor environment,

More information

powerperfector Voltage Power Optimisation

powerperfector Voltage Power Optimisation powerperfector Voltage Power Optimisation IAN GODDARD powerperfector INTRODUCTION Voltage Power Optimisation is one of Japan s most advanced scientific inventions of recent times. (100V) Principally invented

More information

Underbridge Inspection Units Road Rail Access Technique Tunnel Inspection Units

Underbridge Inspection Units Road Rail Access Technique Tunnel Inspection Units 1 Underbridge Inspection Units Road Rail Access Technique Tunnel Inspection Units Content Introduction................................................... 4 5 Underbridge Inspection Units...........................

More information

WIM #37 was operational for the entire month of September Volume was computed using all monthly data.

WIM #37 was operational for the entire month of September Volume was computed using all monthly data. SEPTEMBER 2016 WIM Site Location WIM #37 is located on I-94 near Otsego in Wright county. The WIM is located only on the westbound (WB) side of I-94, meaning that all data mentioned in this report pertains

More information

Tank Farm Additional Storage Site Layout

Tank Farm Additional Storage Site Layout MONTREAL TRUDEAU INTERNATIONAL AIRPORT MIFFC Fuel Committee Meeting Montreal Airport Marriott Hotel, June 15, 2017 Tank Farm Additional Storage Site Layout 1 Tank Farm Additional Storage - Construction

More information

IMILV12 Remove and replace light vehicle transmission and driveline units and components 1

IMILV12 Remove and replace light vehicle transmission and driveline units and components 1 Overview This NOS is about removing and replacing where dismantling and re-assembly of transmission and driveline systems is required. It is also about evaluating the performance of replaced. The units

More information

Status report / Activity Plan of OBD Task Force

Status report / Activity Plan of OBD Task Force -20-12e Status report / Activity Plan of OBD Task Force 26 th Sep., 2017 Mayumi Sophie Morimoto (JASIC) OBD TF Goal agreed at 1 st OBD TF (15 th Dec. 2016) Develop harmonized OBD GTR by end of 2018*. *Approved

More information

PROFESSIONAL INSTALLATION STRONGLY RECOMMENDED

PROFESSIONAL INSTALLATION STRONGLY RECOMMENDED 100755-2 Installation Instructions PC 4200 PROFESSIONAL INSTALLATION STRONGLY RECOMMENDED Installation Precautions: Roll down window to avoid locking keys in vehicle during installation Avoid mounting

More information

STAFF REPORT INFORMATION ONLY

STAFF REPORT INFORMATION ONLY Insert TTC logo here STAFF REPORT INFORMATION ONLY Presentation: Subway Closures - 2016 Year In Review and 2017 Forecast Date: January 18, 2017 To: From: TTC Board Chief Executive Officer Summary The purpose

More information

HOSHIZAKI ICE DISPENSING BIN MODEL DB-200C (FINAL) PARTS LIST

HOSHIZAKI ICE DISPENSING BIN MODEL DB-200C (FINAL) PARTS LIST NO: 71012 ISSUED: SEPT. 6, 1989 REVISED: FEB. 25, 2002 HOSHIZAKI ICE DISPENSING BIN MODEL DB-200C (FINAL) PARTS LIST J-1 JULY 1989 J-2 OCTOBER 1989 K-1 DECEMBER 1989 K-2 SEPTEMBER 1990 A-0 MARCH 1991 A-1

More information

WIM #41 CSAH 14, MP 14.9 CROOKSTON, MINNESOTA APRIL 2014 MONTHLY REPORT

WIM #41 CSAH 14, MP 14.9 CROOKSTON, MINNESOTA APRIL 2014 MONTHLY REPORT WIM #41 CSAH 14, MP 14.9 CROOKSTON, MINNESOTA APRIL 2014 MONTHLY REPORT In order to understand the vehicle classes and groupings, the MnDOT Vehicle Classification Scheme and the Vehicle Classification

More information

I N S T A L L A T I O N G U I D E

I N S T A L L A T I O N G U I D E I N S T A L L A T I O N G U I D E APPLICATION AMP Part # Jeep Wrangler Unlimited (JK) 2007 2017 78122-01A (4-Door Only) INSTALLATION TIME 3-5 Hours Professional installation recommended SKILL LEVEL 1 2

More information

INSTALLATION INSTRUCTIONS COMMERCIAL ROOM VENTILATORS WITH EXHAUST. For Use with Bard CH Series 3, 4, & 5 Ton Wall Mount Heat Pumps

INSTALLATION INSTRUCTIONS COMMERCIAL ROOM VENTILATORS WITH EXHAUST. For Use with Bard CH Series 3, 4, & 5 Ton Wall Mount Heat Pumps INSTALLATION INSTRUCTIONS COMMERCIAL ROOM VENTILATORS WITH EXHAUST MODEL CHCRV-5 For Use with Bard CH Series 3, 4, & 5 Ton Wall Mount Heat Pumps Bard Manufacturing Company, Inc. Bryan, Ohio 43506 Since

More information

Operating Instructions Pedestrian Turnstile Type MPT 33

Operating Instructions Pedestrian Turnstile Type MPT 33 Operating Instructions Pedestrian Turnstile Type MPT 33 Contents 1. Delivery...2 2. Safety...2 3 Description and operation...3 4. Foundation...4-5 5. Assembly and installation...6-9 6. Electrical connection...10-11

More information

PRODUCT: Install Instructions, MV-1 C/O Std, With Aux Fan RELEASE DATE: 2/28/14 REVISION DATE: 9/30/2014 PART NUMBER: Rev C

PRODUCT: Install Instructions, MV-1 C/O Std, With Aux Fan RELEASE DATE: 2/28/14 REVISION DATE: 9/30/2014 PART NUMBER: Rev C Parts List (1) 01 000 027 Switch, 4 Position Blower (1) 04 000 007 Hose, 1/2 ID Drain, 6 (1) 01 000 087 Harn, Resistor (1) 04 000 078 Tube, Convo 1/2 x 24 (2) 01 000 136 Relay, 40 Amp (1) 04 000 015 Hose,

More information

Inspector's Initials: Tank Owner or Agent Signature: Title: Date:

Inspector's Initials: Tank Owner or Agent Signature: Title: Date: STATE OF TENNESSEE DEPARTMENT OF ENVIRONMENT AND CONSERVATION DIVISION OF UNDERGROUND STORAGE TANKS 4 TH Floor, L & C Tower 401 Church Street Nashville, TN 37243-1541 UST OPERATIONS INSPECTION Mo /Day

More information

A Derailment Investigation Leads to Broken Spikes. Brad Kerchof Research & Tests

A Derailment Investigation Leads to Broken Spikes. Brad Kerchof Research & Tests A Derailment Investigation Leads to Broken Spikes Brad Kerchof Research & Tests 1 Google Earth image of the derailment site Vandergrift, PA, January 2014 8.3 curve, river grade (0.3% descending to 0%)

More information

n Photo may include optional equipment HYUNDAI DIESEL FORKLIFT TRUCKS - Stage IIIB emissionised engine 50/60/70D-7A

n Photo may include optional equipment HYUNDAI DIESEL FORKLIFT TRUCKS - Stage IIIB emissionised engine 50/60/70D-7A n Photo may include optional equipment HYUNDAI DIESEL FORKLIFT TRUCKS - Stage IIIB emissionised engine 50/60/70D-7A 02 n Photo may include optional equipment FORKLIFT Excellent model NEW Diesel Engine

More information

INSTALLATION INSTRUCTIONS MKIV Toyota Supra Manual Rack Conversion

INSTALLATION INSTRUCTIONS MKIV Toyota Supra Manual Rack Conversion INSTALLATION INSTRUCTIONS MKIV Toyota Supra Manual Rack Conversion 1 Removal of Stock Rack 1.1 With your steering wheel centered, remove the pinch bolt from the factory intermediate shaft. This is located

More information

CEO PROGRAM September 2018

CEO PROGRAM September 2018 CEO PROGRAM September 2018 1 Sept 17th: ALL! CEO High Orientation (Kiva 6pm 7:30pm) 2 3 4 5 6 7 8 Sept 18th: ALL! CEO Orientation (Kiva 6pm 7:30pm) 9 10 11 12 13 14 15 *Parents please drop off/pick up

More information

DESCRIPTION & OPERATION

DESCRIPTION & OPERATION DESCRIPTION & OPERATION BRAKE BOOSTER Delco-Moraine Single Diaphragm A combined vacuum-hydraulic unit which uses a combination of intake manifold vacuum and atmospheric pressure to provide power assist.

More information

INSTALLATION MANUAL. BULLET PROOF VK Oil Cooler Kit F-SERIES

INSTALLATION MANUAL. BULLET PROOF VK Oil Cooler Kit F-SERIES INSTALLATION MANUAL BULLET PROOF VK688-100 Oil Cooler Kit 2003-2007 F-SERIES NEAL TECHNOLOGIES, INC. U.S. PATENT 8, 887, 688. OTHER PATENTS PENDING UPDATED 1/2/2018 Read BEFORE You Begin Installation These

More information

P.O BOX 429, NUKU ALOFA, Tel: (676) Fax: (676)

P.O BOX 429, NUKU ALOFA, Tel: (676) Fax: (676) P.O BOX 429, NUKU ALOFA, Tel: (676) 27-390 Fax: (676) 23-047 Email: jvanbrink@tongapower.to 22 October 2012 Lord Dalgety Electricity Commission Tu atakilangi Nuku alofa Dear Lord Dalgety Compliance Reporting

More information

Halton Rex 600 RE6 - Adaptable active chilled beam

Halton Rex 600 RE6 - Adaptable active chilled beam Halton Rex 600 RE6 - Adaptable active chilled beam Halton Rex 600 chilled beam is: Combined cooling, heating, and supply air unit for flush installation within a suspended ceiling. Well suited for spaces

More information

2) Mark wall at 5 10 for center line of bottom bolt-hole in wall brackets on transition box side of floor.

2) Mark wall at 5 10 for center line of bottom bolt-hole in wall brackets on transition box side of floor. IN-BAY INSTALLATION 1) Set up transit or level to determine highest point on the floor. From this point establish a level line from which to mark the bracket height on the walls. 2) Mark wall at 5 10 for

More information

Status of the Nuclotron-M project

Status of the Nuclotron-M project Status of the Nuclotron-M project PAC for Particle Physics, Dubna, 14 Jan 2010 G. Trubnikov for the project team NICA: Nuclotron based Ion Collider facility Nuclotron provides now performance of experiments

More information

Page 1 of 9 303-01C Engine 6.0L Diesel 2004 F-Super Duty 250-550/Excursion DESCRIPTION AND OPERATION Procedure revision date: 08/06/2003 Engine Printable View Engine Description The 6.0L diesel engine

More information

List Price Sheet January 1, 2014

List Price Sheet January 1, 2014 List Price Sheet January 1, 2014 300 Pond St. 781.986.2424 Randolph, MA 02368 Fax 781.986.2029 www.flexconind.com FLEXCON STEEL WELL TANKS Materials of Construction Top and bottom domes: 16 gauge cold

More information

MCset 17.5 kv. Civil engineering guide April Medium Voltage Distribution

MCset 17.5 kv. Civil engineering guide April Medium Voltage Distribution Medium Voltage Distribution MCset 17.5 kv ir insulated switchboard Withdrawable switchgear SF6 or vaccum technology Civil engineering guide pril 2012 Contents General 2 Glossary 2 Dimensions and weights

More information

7 Services Control and monitoring

7 Services Control and monitoring Control and monitoring 7 Services We are the only manufacturer of laboratory equipment who offers you fume cupboards and variable fume cupboard control all from one supplier. Benefit from our know-how

More information

Fruitland 250,370 and 500 Pump Rebuild Procedure

Fruitland 250,370 and 500 Pump Rebuild Procedure Fruitland 250,370 and 500 Pump Rebuild Procedure - Drain oil by removing drain plug and check any contaminations in oil. - Remove the four bolts and aluminum sealing washers that connect the outer cover

More information

Wiring Harness 1. Remove left hand footwell trim panel from driver s footwell. Typically secured by several Philips head screws.

Wiring Harness 1. Remove left hand footwell trim panel from driver s footwell. Typically secured by several Philips head screws. Installation There are four segments to the installation; wiring harness, EDIS and Megajolt, coil pack, and Timing wheel and VR sensor. If the car needs to be driven, install everything except the coil

More information

MAKE OF AUTOMOBILE: GRAND VOYAGER STOW`N GO MODEL YEAR: NUMBER: 076/ Copyright Prins Autogassystemen B.V DATE:

MAKE OF AUTOMOBILE: GRAND VOYAGER STOW`N GO MODEL YEAR: NUMBER: 076/ Copyright Prins Autogassystemen B.V DATE: MAKE OF AUTOMOBILE: CHRYSLER TYPE: GRAND VOYAGER STOW`N GO TANK CAPACITY: 2X 36Liter Stako toroidal TANK LOCATION FRONT SEAT ROOM MODEL YEAR: NUMBER: 076/3211036 Copyright Prins Autogassystemen B.V. 2008

More information

Illinois Safety Program IDOT District ATSSA Workshop

Illinois Safety Program IDOT District ATSSA Workshop Illinois Safety Program IDOT District ATSSA Workshop Roadway Departure & MASH DRAFT IDOT Facilitator: Dave Piper ATSSA Facilitator: Jim Thonn 1 Illinois Emphasis Area Priority Pyramid 2 Fatalities and

More information