Smart Lamp Operating System

Size: px
Start display at page:

Download "Smart Lamp Operating System"

Transcription

1 Smart Lamp Operating System 1000 Watt Metal Halide Lamp (Clear) Technical Data Sheet Proprietary to Musco Lighting Physical Characteristics Bulb Size...BT-56 Bulb Finish...Clear Base...Mogul Screw Position Oriented Maximum Overall Length (MOL) " (391mm) Light Center Length (LCL) " (232mm) Arc Tube Lighted Length " (84mm) Arc Tube Material...Fused Silica Maximum Permissible Bulb Temperature C (752 F) Maximum Permissible Base Temperature C (410 F) Ordering Information Ordering Code...LA-10Z ANSI Designation...M47 Description...MH1000 MZ Lamp Type...HID: Metal Halide Photometric Operating Characteristics 1 System Rated Constant Lumens Over Life ,000 Operating Position...Arc Tube Horizontal Lamp Replacement Interval, Hours ,000 Correlated Color Temperature (Approximate) K CIE Chromaticity Coordinates (Approximate)...x-.370, y-.390 Color Rendering Index (R a ) Electrical Data Average Lamp Wattage Over Operating Life Warm-up Time to 80% of Output Minutes Re-strike Time for Hot Lamp Minutes Lamp Operating Current (Max. rms Amps) Ballast Type...ANSI M48 Minimum Starting Temperature C Footnotes: (1) Operating Characteristics are per the Musco Smart Lamp(TM) Operating System on a commercial ballast with arc tube horizontal. Lamp lumen measurements in accordance with IESNA LM Lamp color data in accordance with IESNA LM (2) Lamp starts out at a reduced wattage and increases over life to offset lumen loss as lamp ages. Average wattage over life is 1038 watts. (3) Beyond 12,000 hours is the time when constant lumens are no longer maintained by the Smart Lamp Operating System. Average lamp life before failure is greater than 12,000 hours as tested and defined per IESNA LM with ten hours per start. (4) Does not include ballast losses Musco Lighting Patents Issued & Pending. 800/ lighting@musco.com T-715-1

2 Recommended Warnings, Cautions and Operating Instructions WARNING: These lamps can cause serious skin burn and eye inflammation from short wave ultraviolet radiation if outer envelope of the lamp is broken or punctured. Do not use where people will remain for more than a few minutes unless adequate shielding or other safety precautions are used. Certain lamps that will automatically extinguish when the outer envelope is broken or punctured are commercially available. This lamp complies with FDA radiation performance standard 21 CFR subchapter J. (USA:21CFR Canada:SOR/DORS/80-381) If the outer bulb is broken or punctured, turn off at once and replace the lamp to avoid possible injury from hazardous short wave ultraviolet radiation. Do not scratch the outer bulb or subject it to pressure as this could cause the outer bulb to crack or shatter. A partial vacuum in the outer bulb could cause glass to fly if the envelope is struck. WARNING: The arc-tube of metal halide lamps are designed to operate under high pressure and at temperatures up to 1000 C and can unexpectedly rupture due to internal or external factors such as a ballast failure or misapplication. If the arc-tube ruptures for any reason, the outer bulb may break and pieces of extremely hot glass might be discharged into the surrounding environment. If such a rupture were to happen, THERE IS A RISK OF PERSONAL INJURY, PROPERTY DAMAGE, BURNS AND FIRE. RELAMP FIXTURES AT OR BEFORE THE END OF RATED LIFE. Allowing lamps to operate until they fail is not advised and may increase the possibility of inner arc tube rupture. CAUTION: TO REDUCE THE RISK OF PERSONAL INJURY, PROPERTY DAMAGE, BURNS AND FIRE RESULTING FROM AN ARC TUBE RUPTURE, THE FOLLOWING LAMP OPERATING INSTRUCTIONS MUST BE FOLLOWED. Hg - LAMP CONTAINS MERCURY Manage in Accord with Disposal Laws See or call Lamp Operating Instructions: 1. Turn off lamps at least once a week for at least 15 minutes in systems which are operating on a continuous basis (24 hours/day-7days/week). FAILURE TO TURN OFF LAMPS FOR THE MINIMUM RECOMMENDED TIME MAY INCREASE THE POSSIBILITY OF AN INNER ARC-TUBE RUPTURE. 2. RELAMP FIXTURES AT OR BEFORE THE END OF RATED LIFE. Allowing lamps to operate until they fail is not advised and may increase the possibility of inner arc tube rupture. 3. Before lamp installation/replacement, shut power off and allow lamp and fixture to cool to avoid electrical shock and potential burn hazards. 4. Use only auxiliary equipment meeting Philips and/or ANSI standards. Use within voltage limits recommended by ballast manufacturer. A. Operate lamp only within specified limits of operation. B. For total supply load, refer to ballast manufacturers electrical data. 5. Periodically inspect the outer envelope. Replace any lamps that show scratches, cracks or damage. 6. If a lamp bulb support is used, be sure to insulate the support electrically to avoid possible decomposition of the bulb glass. 7. Protect lamp base, socket and wiring against moisture, corrosive atmospheres and excessive heat. 8. Time should be allowed for lamps to stabilize in color when turned on for the first time. This may require several hours of operation, with more than one start. Lamp color is also subject to change under conditions of excess vibration or shock, and color appearance may vary between individual lamps. 9. Lamps may require 10 to 20 minutes to re-light if there is a power interruption. 10. Take care in handling and disposing of lamps. If an arc tube is broken, avoid skin contact with any of the contents or fragments. 11. Do not use this lamp in a fixture that contains a Pulse Start metal halide ballast and is specifically designed for use with Pulse Start metal halide lamps. 12. Use only in an enclosed fixture capable of withstanding particles of glass having temperatures up to 1000 C.

3 Smart Lamp Operating System Ballast and Capacitor Technical Data Sheet 1000 Watt Metal Halide Lamp 60Hz ANSI Code M47 Constant Wattage Autotransformer (CWA) volts, 60 Hz Input Volts Power Factor (minimum) 90% Regulation 10% Lamp Watts 10% Line Current (Amperes) Operating (min/max) 8.6/ / / / / / /3.6 Open Circuit Starting (max) UL Temperature Ratings Insulation Class H (180 deg. C) Coil Temperature Code 1029 F F B D D B C Min. Ambient Starting Temperature -20 F or -20 F or -30 F or -20 F or -20 F or -20 F or -30 F or -30 C -30 C -35 C -30 C -30 C -30 C -35 C Nominal Open Circuit Voltage Input Voltage at Lamp Dropout Input Watts (nominal) 1121 Fuse Rating (amperes) Testing Procedures High Potential Test (volts) 1 minute 2 seconds Open Circuit Voltage Test (volts) Short-Circuit Current Test (Amps) Secondary Current Input Current Catalog Number Ballast Dimensions 4.38" [111.1mm].25" [6.4mm] Diameter Weight = 31 lbs. [14kg].81" [20.6mm] SC-306 Typical Wiring or SC SC-302 SC-306 Capacitor Rating: 2.2/ Minimum Withstand Voltage 525 E -20 F or -30 C SC " [98.3mm] 4.25" [108mm] Smart Lamp Control Capacitor 2.50 [63.5mm].19" [4.8mm] 6.00" [152.4mm] COM COM Lamp 2.50 [63.5mm] 6.04 [153.4mm] 6.25" max [158.8mm] 4.25" [108mm] Notes: 2008 Musco Lighting T-253-1

4 Luminaire Assembly Left View Aluminum spill and glare light control Stainless steel latch bail Lamp Silicone glass edge seal gasket Silicone O ring rim seal Tempered glass lens Aluminum lens rim Stainless steel chain Aluminum over-center latch handle Luminaire wireway: 2 x 4 inch nominal, 1/8 inch thick, high strength steel tubing Horizontal aiming adjustment (factory set) Die-cast aluminum mounting plate Die-cast aluminum knuckle Mogul lamp socket Geared tilt adjustment Die-cast aluminum lamp cone Teflon centering/sealing ring Silicone O ring seal Joint seal overlap Die-cast aluminum reflector housing 3 /8 activated carbon filter Repositioning stop (factory set) Viton O ring seal Knuckle positioning bolt Silicone O ring seal Right View Lamp leveling gear drive Vertical aiming adjustment/lock (factory set) Luminaire Weight : 13.9 Kg Musco p roducts referenced o r show n are protected by o ne or mo re of the followi ng U. S. Patents: ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; D337168; D353797; D353911; D A ustralia Patents: ; C ana da Patents: 70479; 73755; 74939; 89366; ; ; ; ; ; ; ; ; ; ; EPC P atents: ; Germany P atents: Mexico P atents: ; New Ze aland P atents: ; South Ko rea Patents: Othe r patents pe nding M usco Lighti ng SLA1 800/ us co.com lighti ng@m us co.com

5 Hour meter

6 Poletop Luminaire Assembly Pole cap securing bolt Pole cap Pole cap safety cable Quick connect plug-in Crossarm Luminaire mounting plate Knuckle assembly Reflector housing Lamp Enclosed quick connect matching plug-ins on luminaire assembly and mounting plate (not shown) Snap hook for wire support grip Cone Crossarm wiring Pole shaft Spill and glare control visor Jacking ears Set screw MKT-2583 Musco products referenced or shown are protected by one or more of the following U.S. Patents: ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; D337168; D353797; D353911; D Australia Patents: ; Canada Patents: 70479; 73755; 74939; 89366; ; ; ; ; ; ; ; ; ; ; EPC Patents: ; Germany Patents: Mexico Patents: ; New Zealand Patents: ; South Korea Patents: Other patents pending Musco Lighting SPLA1 800/

Multi-Vapor Metal Halide Lamps

Multi-Vapor Metal Halide Lamps GE Lighting Multi-Vapor Metal Halide Lamps Elliptical Clear 175W, 250W, 400W and 00W Elliptical Diffuse 175W, 250W and 400W High Output Elliptical Clear & Diffuse 250W and 400W DATA SHEET Product information

More information

Protected Spaces Philips TuffGuard Coated Lamps

Protected Spaces Philips TuffGuard Coated Lamps Protected Spaces Philips TuffGuard Coated Lamps Protect your customers, employees, and reputation. Coated lighting is essential to ensure the welfare of your customers, employees, and operation. Philips

More information

MasterColor CDM-R111 70W/830 10D 1CT

MasterColor CDM-R111 70W/830 10D 1CT MasterColor CDM-R111 70W/830 10D 1CT Product family description Philips MasterColor CDM-R111 combines the trendy look of the 111mm aluminum reflector halogen lamps with the long life, high energy efficiency

More information

Lamps CERAMIC METAL HALIDE

Lamps CERAMIC METAL HALIDE s CERAMIC METAL HALIDE CERA ARC EX / Outdoor CERA ARC PRO / Indoor Long up to 24000 hrs Low maintenance s need to be changed less often, therefore saving on maintenance costs, reducing waste, and lessening

More information

AFL FLOODLIGHT SERIES

AFL FLOODLIGHT SERIES AFL FLOODLIGHT SERIES A FL Flood Lighting for Hazardous Locations Class I, Division 2, Groups A, B, C & D UL 844 Hazardous Locations UL 598A Marine Outside Type Zone 2, Groups IIA, IIB & IIC CUL Cast Aluminum

More information

The Double Ended DE Metal Halide lamp types, up to 1800 micromol/s, are available in 1000W, 6000K for Open rated fixtures.

The Double Ended DE Metal Halide lamp types, up to 1800 micromol/s, are available in 1000W, 6000K for Open rated fixtures. HiLux Gro PROFESSIONAL GRADE HORTICULTURE LAMPS Professional growers will not use just any lamps to get just any results. They require specialty-grade lamps to maximize their growth and profits. This is

More information

Areamaster 100 Wide-Beam Floodlights 70 W, 100 W, 150 W HPS; 70 W, 100 W, 150 PSMH For general, marine and hazardous locations.

Areamaster 100 Wide-Beam Floodlights 70 W, 100 W, 150 W HPS; 70 W, 100 W, 150 PSMH For general, marine and hazardous locations. Areamaster 100 Wide-Beam Floodlights NEC CEC V Class II, Divisions I and 2, Groups E, F, G V Class III Applications Highly efficient, all-weather flood-lighting for lower wattage service. Well suited for:

More information

HIGH PRESSURE SODIUM. EYE Lighting Volume 6 Catalogue

HIGH PRESSURE SODIUM. EYE Lighting Volume 6 Catalogue HIGH PRESSURE SODIUM Initial Sunlux ACE - BT & Elliptical Clear For use with Mercury Vapour Control Gear (IEC 60188) 120230 75 Clear Universal NH75-LX/70S 115 0.80 6500 2100 25 20000 86 E27 1 s 120235

More information

A2CO Series. Aktra II Cutoff Floodlight, W HID. Overall Dimensions. Specifications EPA Effective Projected Area.

A2CO Series. Aktra II Cutoff Floodlight, W HID. Overall Dimensions. Specifications EPA Effective Projected Area. Catalog Number: Approvals: - - - - - Series/Source-Wattage Optics Voltage Mounting Options Finish (Reflector) (Factory Installed) Overall Dimensions 16 (40.6 cm) 8.9 (22.5 cm) Weight (maximum) 20.5 (52.07

More information

Areamaster 1000 Floodlights Integrally Ballasted W HID For hazardous locations.

Areamaster 1000 Floodlights Integrally Ballasted W HID For hazardous locations. A, IIB, IIC Applications Powerful, efficient weatherproof lighting for large areas such as: Pulp and paper mills Processing plants Chemical plants Oil refineries Foundries Storage areas Waste and sewage

More information

1000 Watt Metal Halide Flood Light - 110,000 Lumens - Slipfitter Mount - 120~277 Volts AC

1000 Watt Metal Halide Flood Light - 110,000 Lumens - Slipfitter Mount - 120~277 Volts AC 1000 Watt Metal Halide Flood Light - 110,000 Lumens - Slipfitter Mount - 120~277 Volts AC Part #: MHFL-1000W Made in the USA The powerful and efficient MHFL-1000W metal halide light fixture from Larson

More information

ExceLine 1611 Clovis R. Barker Road San Marcos, TX Fax: PT#: EXSP072A0812

ExceLine 1611 Clovis R. Barker Road San Marcos, TX Fax: PT#: EXSP072A0812 Type No. Catalog No. Job. Name WL Series APPLICATIONS Applications include low ceiling applications, light industrial manufacturing facilities, offices, lobbies, conference rooms, food processing plants,

More information

Overall Dimensions. Specifications

Overall Dimensions. Specifications Overall Dimensions EFX B EFX VM Vertical Mount C 13 housing (70-400W) 19 housing (450-1000W) E D H B C D E 13.3 16.8 16.2 7.0 9.8 (33.78cm) (42.67cm) (41.15cm) (17.78cm) (24.89cm) F G H I J 22.2 11.3 6.3

More information

Arcstream Double Ended

Arcstream Double Ended GE Lighting Arcstream Double Ended Metal Halide lamps 7W, 15W and 25W Product Information High brightness, high quality white and coloured light with good colour rendition, excellent colour consistency

More information

OP2 CosmoPolis Series

OP2 CosmoPolis Series Catalog Number: Approvals: - - - - - Series/Source-Wattage Optics E ballast Voltage Mounting Options Finish (Factory Installed) Accessories (Field Installed) Date: Page of 6 Overall Dimensions OP2 arm

More information

EAL Series. Effex Area Luminaire, W HID. Overall Dimensions. Specifications Approvals: Catalog Number: Date: Page 1 of 6

EAL Series. Effex Area Luminaire, W HID. Overall Dimensions. Specifications Approvals: Catalog Number: Date: Page 1 of 6 Catalog Number: Approvals: - - - - - Series/Source-Wattage Optics Voltage Mounting Options Finish (Distribution) (Factory Installed) Accessories (Field Installed) Date: Page 1 of 6 Overall Dimensions EAL

More information

STATE OF NEW JERSEY DEPARTMENT OF TRANSPORTATION TRENTON, NEW JERSEY SPECIFICATIONS FOR HIGH PRESSURE SODIUM LUMINAIRES HIGH MAST TYPE

STATE OF NEW JERSEY DEPARTMENT OF TRANSPORTATION TRENTON, NEW JERSEY SPECIFICATIONS FOR HIGH PRESSURE SODIUM LUMINAIRES HIGH MAST TYPE STATE OF NEW JERSEY DEPARTMENT OF TRANSPORTATION TRENTON, NEW JERSEY 08625 SPECIFICATIONS FOR HIGH PRESSURE SODIUM LUMINAIRES HIGH MAST TYPE N.J. Specification No. Effective Date: July 1, 2001 New Jersey

More information

Catalog Number UPC Number Features. General Lumen Output: 2300 Color Temperature: 5000K Cool White CRI: 70+ Housing Color: Black

Catalog Number UPC Number Features. General Lumen Output: 2300 Color Temperature: 5000K Cool White CRI: 70+ Housing Color: Black Catalog Number 71376 UPC Number 601986713764 Description LED Bullet Flood Light 30 W 2300 Lumens Features Cree CXA LED s, CRI: 70+ Voltage: 120-277VAC Isolated Driver Compartment for Optimal Thermal Management

More information

Overall Dimensions. Specifications

Overall Dimensions. Specifications Overall Dimensions EFI Mastfitter Mount (MA2) (standard) A 70-400W HID unit: 13 Housing A B C 13.3 11.3 23.3 (33.78cm) (28.70cm) (59.18cm) 750-1000W HID and 85-165W QL unit: 19 Housing A B C 19.4 14.9

More information

Catalog Number UPC Number Features. General Lumen Output: 800 Color Temperature: 5000K Cool White CRI: 70+ Housing Color: Black

Catalog Number UPC Number Features. General Lumen Output: 800 Color Temperature: 5000K Cool White CRI: 70+ Housing Color: Black Catalog Number 71372 UPC Number 601986713726 Description LED Bullet Flood Light 1 LED 800 Lumen Features Cree CXA LED s, CRI: 70+ Voltage: 120-277VAC Isolated Driver Compartment for Optimal Thermal Management

More information

220/230/240V Watt High Pressure Sodium - Hazardous Location Lighting - C1D2 - Pole Mount

220/230/240V Watt High Pressure Sodium - Hazardous Location Lighting - C1D2 - Pole Mount 220/230/240V Watt High Pressure Sodium - Hazardous Location Lighting - C1D2 - Pole Mount Part #: HAL-PRM-250W-HPS-220V-PT Page: 1 Made in the USA The efficient HAL-PRM-250W-HPS-220V-PT high pressure sodium

More information

SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE INSTALLATION INSTRUCTIONS SECURITY HID CAUTIONS: DIRECT MOUNTING TO RECESSED BOX (WALL OR CEILING)

SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE INSTALLATION INSTRUCTIONS SECURITY HID CAUTIONS: DIRECT MOUNTING TO RECESSED BOX (WALL OR CEILING) INSTALLATION INSTRUCTIONS SECURITY HID Document: CI308X61R0 Date: 2013-4-18 Created By: TMT DCR#: 2013-138 FIGURE 1 FIGURE 2 CAUTIONS: IMPORTANT SAFEGUARDS When using electrical equipment, basic safety

More information

Altman Stage Lighting Safety Instructions & Warnings UV-250 Blacklight Floodflight

Altman Stage Lighting Safety Instructions & Warnings UV-250 Blacklight Floodflight Altman Stage Lighting Safety Instructions & Warnings UV-250 Blacklight Floodflight UV-250 Safety Instructions WARNING! - TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK, OR INJURY TO PERSONS, FOLLOW THE IMPORTANT

More information

COMMERCIAL DE LIGHT SYSTEM INSTALLATION AND TECHNICAL MANUAL

COMMERCIAL DE LIGHT SYSTEM INSTALLATION AND TECHNICAL MANUAL COMMERCIAL DE LIGHT SYSTEM INSTALLATION AND TECHNICAL MANUAL Thank you for choosing PARsource Lighting Solutions for your installation. Our fixture designs are initiated by grower feedback, and implemented

More information

ExceLine 1611 Clovis R. Barker Road San Marcos, TX Fax: PT#: EXSP038A0712

ExceLine 1611 Clovis R. Barker Road San Marcos, TX Fax: PT#: EXSP038A0712 Type No. Catalog No. Job. Name ILXGHB MasterColor Elite Series APPLICATIONS Applications include industrial facilities, manufacturing plants, retail applications, and gymnasiums. CONSTRUCTION The ILX MasterColor

More information

Product Description. TL-D Standard Colours. Low-pressure mercury discharge lamps with a tubular 26 mm envelope

Product Description. TL-D Standard Colours. Low-pressure mercury discharge lamps with a tubular 26 mm envelope Product Description TL-D Standard Colours Low-pressure mercury discharge lamps with a tubular 26 mm envelope Benefits Create atmospheres from warm white to cool daylight Features Standard colors with moderate

More information

AerolumeTM. Collection. Area Luminaires 3 Fixture Sizes W HID 64/80/120

AerolumeTM. Collection. Area Luminaires 3 Fixture Sizes W HID 64/80/120 Aerolume Collection Area Luminaires Fixture Sizes 70-00W HID 64/80/ Overview Mini-Aerolume Aerolume Aerolume-G 1." (4.9mm) 18" (47.mm) " (84.mm) 6." (16.1mm) 19" (48.6mm) 4" (1.4mm) 8" (0.mm) " (84.mm)

More information

IMPORTANT SAFETY INSTRUCTIONS

IMPORTANT SAFETY INSTRUCTIONS IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION To reduce the risk of death, personal injury or property damage from

More information

Lucalox XO High Pressure Sodium Lamps with improved reliability Lucalox TM XO Tubular Clear 50W, 70W, 100W, 150W, 250W, 400W & 600W

Lucalox XO High Pressure Sodium Lamps with improved reliability Lucalox TM XO Tubular Clear 50W, 70W, 100W, 150W, 250W, 400W & 600W GE Lighting Lucalox XO High Pressure Sodium Lamps with improved reliability Lucalox TM XO Tubular Clear W, W, W, 1W, 2W, W & W DATA SHEE T Lucalox TM XO Elliptical Diffuse W, W, W, 1W, 2W & W Product information

More information

SOURCE TE- Electronic MH. OPTIONS See Below OPTIONS. L = Lamped BLANK = General Purpose Optics A = Asymmetric Optics S = Spot

SOURCE TE- Electronic MH. OPTIONS See Below OPTIONS. L = Lamped BLANK = General Purpose Optics A = Asymmetric Optics S = Spot CATALOG NO. TYPE NO. JOB NAME -8 GP Flood Series Floodlighting GP (Mini) ORDERING INFORMATION Catalog Number: Example: GPA070TEL GP A TE SERIES GP-General Purpose Flood SIZE -Mini ACCESSORIES GPGS = Visor

More information

Lucalox PSL. GE Lighting DATASHEET. Lucalox PSL Tubular Clear 230V 250W, 400W, 600W and 750W Lucalox PSL Tubular Clear 400V 600W and 750W

Lucalox PSL. GE Lighting DATASHEET. Lucalox PSL Tubular Clear 230V 250W, 400W, 600W and 750W Lucalox PSL Tubular Clear 400V 600W and 750W GE Lighting Lucalox PSL Lucalox PSL Tubular Clear 23V 25W, 4W, 6W and 75W Lucalox PSL Tubular Clear 4V 6W and 75W Superb performance and high reliability DATASHEET GE s advanced sodium resistant ceramic

More information

LED Trouble Light / Hand Lamp / Drop Light -10 Watt LED Bulb - 12 Foot SJOW Cord

LED Trouble Light / Hand Lamp / Drop Light -10 Watt LED Bulb - 12 Foot SJOW Cord LED Trouble Light / Hand Lamp / Drop Light -10 Watt LED Bulb - 12 Foot SJOW Cord Part #: WAL-DL-LED-12 Page: 1 Made in the USA The WAL-DL-LED-12 from Larson Electronics is a LED Drop Light / Work Light

More information

136W Wash Down LED Light - 120/277V AC - Food Safe - IP66 Rated - Trunnion Mount

136W Wash Down LED Light - 120/277V AC - Food Safe - IP66 Rated - Trunnion Mount 136W Wash Down LED Light - 120/277V AC - Food Safe - IP66 Rated - Trunnion Mount Part #: WDL-48-400W-LED-TRN-WCM Page: 1 This WDL-48-400W-LED-TRN-WCM Wash Down LED Fixture offers 19,773 lumens of crisp

More information

GE Lighting DATA SHEET. Product information. Features. Applications

GE Lighting DATA SHEET. Product information. Features. Applications GE Lighting Lucalox XO High Pressure Sodium Lamps with improved reliability Lucalox TM XO Tubular Clear 5W, 7W, W, 15W, 25W, 4W & 6W Lucalox TM XO Elliptical Diffuse 5W, 7W, W, 15W, 25W & 4W DATA SHEET

More information

DESCRIPTION & APPLICATION

DESCRIPTION & APPLICATION T5 FME T5 4L - Full Body High Bay DESCRIPTION & APPLICATION The Envirobrite FME T5 fixture is a full body fluorescent high bay ideal for replacing energy devouring HID fixtures. This all aluminum enclosed

More information

Product Description. MASTER HPI-T Plus. Quartz metal halide lamps with clear outer bulb

Product Description. MASTER HPI-T Plus. Quartz metal halide lamps with clear outer bulb Product Description MASTER Plus Quartz metal halide lamps with clear outer bulb Benefits High safety and comfort level, maintained over life Minimal maintenance cost Initial investment saving options with

More information

HID/FLOODLIGHT: NEC/CEC EXPLOSIONPROOF. Applications. Options

HID/FLOODLIGHT: NEC/CEC EXPLOSIONPROOF. Applications. Options Applications UL Listed for Outside Type (Salt Water). Ideal in Class I, Division 1 and 2 installations in refineries, in pipeline transportation facilities, at drilling rigs and in production facilities

More information

STATIC DAYLIGHT PAR 575 VF

STATIC DAYLIGHT PAR 575 VF STATIC LIGHT COMPANY LIMITED Unit 11, Meridian Business Park Fleming Road WALTHAM ABBEY EN9 3BZ www.staticlightcompany.com info@staticlightcompany.com TEL +44 (0) 1992 766 766 THIS INFORMATION IS DESIGNED

More information

ExceLine 1611 Clovis R. Barker Road San Marcos, TX Fax: PT#: EXSP051A0712

ExceLine 1611 Clovis R. Barker Road San Marcos, TX Fax: PT#: EXSP051A0712 Type No. Catalog No. Job. Name PFCB Series APPLICATIONS Applications include assembly areas, industrial facilities, and warehouses. CONSTRUCTION Low profile, heat dissipating die-cast aluminum ballast

More information

Applications. Straight Stanchion-Mount Fixture with Prismatic Glass Refractor and Guard. Pendant Mount Fixture with Prismatic Glass Refractor

Applications. Straight Stanchion-Mount Fixture with Prismatic Glass Refractor and Guard. Pendant Mount Fixture with Prismatic Glass Refractor Mercmaster III HID 50-250 Watt Luminaires Applications Enclosed and gasketed fixtures suitable for use in: Marine and wet locations A wide range of industrial, chemical processing and other areas where

More information

Lighting: Explosionproof Area HID. Applications. Standard Materials

Lighting: Explosionproof Area HID. Applications. Standard Materials Code Master Jr. HID Factory Sealed Luminaires Integrally Ballasted. 50 W, 70 W, 00 W, 50 W HPS; 50 W, 70 W, 00 W, 75 W PSMH. 75 W MH V. Medium Base. For Use with Threaded Metal Conduit. Class I, Division

More information

Standard Grade 14 Inch Reflector. Ordering Information

Standard Grade 14 Inch Reflector. Ordering Information Job Type Dimensions Specifications B A NRTL/C C Damp Location D E Slick- On Quick- On F A B C D E F 9-1/2" 2" 9-1/2" 20-22/32 24-27/32" 9-7/16" 14-1/4" 241 mm 51 mm 241 mm 536-631 mm 240 mm 362 mm 9-1/2"

More information

Light source Power range (W) Up to 125 Input voltage / frequency (v/hz) 230 / 50 Power factor 0.95

Light source Power range (W) Up to 125 Input voltage / frequency (v/hz) 230 / 50 Power factor 0.95 Almas (G17) ɸ 60 ɸ 610 545 Power range () Up to 125 Input voltage / frequency (v/hz) 230 / 50 holder Energy saving lamps / HQL s E27 Bracket holder diameter (mm) ئ 60 Ambient temperature (ºC) 35 Maximum

More information

OkSolar LED Outdoor Luminaires

OkSolar LED Outdoor Luminaires OkSolar 488500 LED Outdoor Luminaires 1.0 PURPOSE The purpose of this specification is to provide the minimum performance requirements for the LED Outdoor Luminaire Fixture. This specification refers to

More information

Lucalox Standard Tubular Clear Product Code * * 11678* LU150/100/ HO/T/E40 LU150 /100/40

Lucalox Standard Tubular Clear Product Code * * 11678* LU150/100/ HO/T/E40 LU150 /100/40 GE Lighting Lucalox Standard High Pressure Sodium lamps Tubular Clear & Elliptical Diffuse 70W, 100W, 150W, 250W, 400W and 1000W DATA SHEET Product information From GE s invention of HPS lighting in 1965

More information

KAD250MR3TBSPD04 Wall Fixture

KAD250MR3TBSPD04 Wall Fixture 8 South Street 796-76, TX Nacogdoches Phone: 96-69-79 Fax: 96-6-68 AllenWatson@elliottelectric.com MRTBSPD Wall Fixture Catalog Number MRTBSPD Manufacturer Description Area Light, Metal Halide Lamp; Lamp

More information

1000 Watt Metal Halide Light - Class 1 Division 2 Groups A-D - T3b Temperature - 110,000 lumens

1000 Watt Metal Halide Light - Class 1 Division 2 Groups A-D - T3b Temperature - 110,000 lumens 1000 Watt Metal Halide Light - Class 1 Division 2 Groups A-D - T3b Temperature - 110,000 lumens Part #: HALPRM-1000WMH Made in the USA The extremely durable Larson Electronics HALPRM-1000WMH metal halide

More information

Lucalox Standard. GE Lighting. Product information. Applications areas

Lucalox Standard. GE Lighting. Product information. Applications areas GE Lighting Lucalox Standard High Pressure Sodium lamps Tubular Clear & Elliptical Diffuse 70W, 100W, 150W, 250W, 400W and 1000W DATA SHEET Product information From GE s invention of HPS lighting in 1965

More information

WPP25 250W MP Wal-Pak Borosilicate Glass Hinged/Removabl

WPP25 250W MP Wal-Pak Borosilicate Glass Hinged/Removabl 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 WPP25 250W MP Wal-Pak Borosilicate Glass Hinged/Removabl Catalog Number Manufacturer Description Weight per unit Product

More information

Applications. Standard Materials

Applications. Standard Materials Code Master Jr. HID Factory Sealed Luminaires Integrally Ballasted. 50 W, 70 W, 00 W, 50 W HPS; 50 W, 70 W, 00 W, 75 W PSMH. 75 W MH V. Medium Base. For Use with Threaded Metal Conduit. Class I, Division

More information

CEC: Class I, Division 1 and 2, Groups B, C, D Class II, Division 1 and 2, Groups E, F, G Class III Type 4X Exd IIB + H 2

CEC: Class I, Division 1 and 2, Groups B, C, D Class II, Division 1 and 2, Groups E, F, G Class III Type 4X Exd IIB + H 2 Integrally Ballasted. 50 W, 70 W, 00 W, 50 W HPS; 75 W PSMH. 75 W MH. Medium Base. For Use with Threaded Metal Conduit. Applications For use in chemical and petrochemical plants, such as manufacturers

More information

14W Linear 2' LED Light Lumens - IP66 - UL 1598A - Stainless Steel Mounting Brackets/Hardware

14W Linear 2' LED Light Lumens - IP66 - UL 1598A - Stainless Steel Mounting Brackets/Hardware 14W Linear 2' LED Light - 1750 Lumens - IP66 - UL 1598A - Stainless Steel Mounting Brackets/Hardware Part #: WDL-24-1L-SS-2X5FT Page: 1 Made in Texas Providing 1,750 lumens of clean, crisp white light

More information

first issue : last change : MSD Platinum 15 R number of pages : 12 LE 2166

first issue : last change : MSD Platinum 15 R number of pages : 12 LE 2166 first issue : 2011-02-07 S FOR MSD Platinum LAMP SYSTEMS last change : 2013-01-11. MSD Platinum 15 R 9281 916 05300 number of pages : 12 Philips Innovative Applications N.V. Specifications subject to change

More information

Saturn Cutoff. Order Code: Pole Order Code: Series Height Finish Options. Customer: Date: Project: Qty: Type: SAC Saturn Cutoff SAC

Saturn Cutoff. Order Code: Pole Order Code: Series Height Finish Options. Customer: Date: Project: Qty: Type: SAC Saturn Cutoff SAC Date: Customer: Project: Type: Qty: Saturn Cutoff Order Code: SAC - - - - - - - - SAC Series SAC Saturn Cutoff Pole Order Code: - - - Series Height Finish Options Optics R Type II Distribution R Type V

More information

SLXP Series ! CAUTION. Cord Plug. Cord Replacement. Installation Instructions

SLXP Series ! CAUTION. Cord Plug. Cord Replacement. Installation Instructions ! CAUTION All wiring should be done by a licensed electrician in accordance with state codes, local codes and National Electric Code (NEC) standards. Improper installation may result in serious injury

More information

TORNADOTM BOLLARD PATENTS PENDING

TORNADOTM BOLLARD PATENTS PENDING TORNADOTM BOLLARD PATENTS PENDING Day Tornado Bollard Unlike any bollard available in today s specification pallet, Tornado offers a new form and character for pedestrian scale lighting. Tornado adds an

More information

HIGH INTENSITY DISCHARGE BALLASTS

HIGH INTENSITY DISCHARGE BALLASTS Philips Advance ballasts are available to operate the wide variety of metal halide, high pressure sodium and low pressure sodium lamps available in today s marketplace. Like fluorescent, lamps are gas

More information

Floodlight. AF1000 Series. Aktra Cutoff Floodlight W HID

Floodlight. AF1000 Series. Aktra Cutoff Floodlight W HID Floodlight AF1000 Series Aktra Cutoff Floodlight 400-1000W HID Unit shown is representative of MAF series with optional marine listing and standard AFS-1000 unit. Project: Location: Cat.No: Type: Lamps:

More information

Product Description. MASTER HPI Plus. Quartz metal halide lamps with opalized outer bulb

Product Description. MASTER HPI Plus. Quartz metal halide lamps with opalized outer bulb Product Description MASTER HPI Plus Quartz metal halide lamps with opalized outer bulb Benefits High safety and comfort level, maintained over life Minimal maintenance cost Initial investment saving options

More information

PGL350P W PS Wallpack

PGL350P W PS Wallpack 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 PGL350P1281 350W PS Wallpack Hubbell Lighting, Inc. Catalog Number Manufacturer Description Weight per unit Product Category

More information

Areamaster LED Flood/High Bay Luminaires

Areamaster LED Flood/High Bay Luminaires Applications Typical applications include: Pulp and paper mills Processing plants Chemical plants Oil refineries Foundries Storage areas Waste and sewage treatment Parking garages Other areas where dust,

More information

LITON FLOOD / SPOT O U T D O O R A D J U S T A B L E L I G H T I N G

LITON FLOOD / SPOT O U T D O O R A D J U S T A B L E L I G H T I N G LITON L I G H T I N G O U T D O O R A D J U S T A B L E FLOOD / SPOT L I G H T I N G ABOVE GRADE O U T D O O R L I G H T I N G The AG-series ground and wall mount luminaires are designed for general landscape

More information

Driver Info. Construction Thermal Management: Superior thermal management with die-cast aluminum heatsink. Ambient Temperature:

Driver Info. Construction Thermal Management: Superior thermal management with die-cast aluminum heatsink. Ambient Temperature: WP3LED55 Project: Type: Prepared By: Date: 82W, 65W and 55W LED wallpacks. Available with up to 9,000 lumens and 121 LPW. Up to 100,000 hour L70 lifespan. 5-Year Warranty. Color: Bronze Weight: 16.8 lbs

More information

Options. Pole and Arm. Suitable for wet locations

Options. Pole and Arm. Suitable for wet locations Catalog number: / / / Mtg. Fixture Electrical Module Finish See page 2 See page 3 Options Pole and Arm Select pole from Kim Arms and Poles Selection Guide. If pole is provided by others indicate O.D. for

More information

Engineering Bulletin. Troubleshooting High Intensity Discharge Lighting Systems Metal Halide, Mercury, and High Pressure Sodium HID011R2

Engineering Bulletin. Troubleshooting High Intensity Discharge Lighting Systems Metal Halide, Mercury, and High Pressure Sodium HID011R2 Engineering Bulletin Troubleshooting High Intensity Discharge Lighting Systems Metal Halide, Mercury, and High Pressure Sodium HID011R2 Introduction This troubleshooting guide is intended to provide the

More information

These new lamps have also yielded many different shapes and sizes of the ballasts, which are required for lamp operation.

These new lamps have also yielded many different shapes and sizes of the ballasts, which are required for lamp operation. Prepared by the Product Administration Group Technical Services Dept. Advance Transformer Co. The High Intensity Discharge (HID) lighting industry has experienced tremendous growth in terms of size, as

More information

Variety of mounting methods. UL, CUL, and CSA listed for general and hazardous locations

Variety of mounting methods. UL, CUL, and CSA listed for general and hazardous locations PREDATOR The Predator floodlight offers versatility, efficiency, and performance, which provides a unique solution to a variety of lighting needs. With the Predator, Holophane continues its legacy of utilizing

More information

SAFJ LED SERIES S A L E D. Hazardous Location Compact LED

SAFJ LED SERIES S A L E D. Hazardous Location Compact LED SAFJ LED SERIES Hazardous Location Compact LED Class I, Division 2, Groups A, B, C, & D Class II, Division 1 & 2, Groups E & F Class III Simultaneous Presence Enclosed & Gasketed Wet Locations NEMA 3R,

More information

LIGHTING: EXPLOSIONPROOF FLOODLIGHT. Applications. Options

LIGHTING: EXPLOSIONPROOF FLOODLIGHT. Applications. Options Code Master 2 HID Factory Sealed Floodlights NEC: Class 1, Division 1 and 2, Groups C, D Marine Type Electric Fixtures Outside Type (Salt Water) CEC: V Class I, Division 1 and 2, Groups B, C, D Class II,

More information

2 LED downlight. Discreet styling, bold performance. RABWEB.COM

2 LED downlight. Discreet styling, bold performance. RABWEB.COM 2 LED downlight Discreet styling, bold performance. RABWEB.COM 888 722-1000 Clean, unobtrusive design delivers smooth and abundant light from an aperture just over 1 inch wide. 8W replaces 50W MR16 with

More information

F Series (available MF Series: Marine Listed with optional hazardous location listing)

F Series (available MF Series: Marine Listed with optional hazardous location listing) Catalog Number: Approvals: Overall Dimensions - - - - Series/Source - Wattage Optics Voltage Options Finish (Include M prefi x to designate ( / (Factory Installed) Marine Listed series) Distribution) E

More information

LEDMPAL15 15 Watt Multi-Purpose LED Area Light

LEDMPAL15 15 Watt Multi-Purpose LED Area Light LEDMPAL15 15 Watt Multi-Purpose LED Area Light Project: Type: Catalog #: STANDARD FEATURES WET 1kV Surge Protection Available in 3000k (warm white), 4000K (neutral white) and 5000K (cool white). * Long-life

More information

Series Mounting Accessory Distribution Source Color Temperature Voltage 10DEG 20DEG 40DEG 60DEG 60X20DEG

Series Mounting Accessory Distribution Source Color Temperature Voltage 10DEG 20DEG 40DEG 60DEG 60X20DEG 700YK1 SMALL YOKE MOUNT 5 7-3/4 (321mm) 700KNL1 KNUCKLE MOUNT 5 7-3/8 (171mm) 6-3/16 (157mm) 6-3/16 (157mm) Construction Rugged die cast aluminum housing with clear tempered glass lens & 100% silicone

More information

Heavy industrial LED lighting Champ Pro PFM LED luminaires. Champ PFM. LED floodlights for heavy industrial areas. Authorized Distributor

Heavy industrial LED lighting Champ Pro PFM LED luminaires. Champ PFM. LED floodlights for heavy industrial areas. Authorized Distributor Heavy industrial LED lighting Champ Pro PFM LED luminaires Champ PFM LED floodlights for heavy industrial areas Authorized Distributor Champ Pro PFM LED floodlights Safe. Reliable. Efficient. Featuring

More information

ConstantColor CMH TD. GE Lighting DATA SHEET. Double Ended Ceramic Metal Halide Lamps 35W, 70W and 150W. Product information.

ConstantColor CMH TD. GE Lighting DATA SHEET. Double Ended Ceramic Metal Halide Lamps 35W, 70W and 150W. Product information. GE Lighting ConstantColor CMH TD Double Ended Ceramic Metal Halide Lamps 35W, 7W and 15W DATA SHEET Product information ConstantColor CMH lamps combine the HPS technology (providing stability, efficiency

More information

Qty: L50 50W. B4 Two 12V 146 Ah. B5 One 12V 176 Ah. P4 150W Double. 4 XXX 4 hours PM 0 hours AM. 5 XXX 6 hours PM 0 hours AM PM4 45 PM6 60.

Qty: L50 50W. B4 Two 12V 146 Ah. B5 One 12V 176 Ah. P4 150W Double. 4 XXX 4 hours PM 0 hours AM. 5 XXX 6 hours PM 0 hours AM PM4 45 PM6 60. Date: Customer: Project: Type: Qty: Avanza 450 LED Solar Order Code: AV4LS - - - - - - - - - - AV4LS Series AV4LS Avanza 450 LED Solar Optics RW Type III Distribution (Wide) RN Type III Distribution (Narrow)

More information

1000W High Intensity LED Crane Light - 110,000 Lumens V AC - Stainless Steel Bracket

1000W High Intensity LED Crane Light - 110,000 Lumens V AC - Stainless Steel Bracket 1000W High Intensity LED Crane Light - 110,000 Lumens - 347-480V AC - Stainless Steel Bracket Part #: GAU-HB-1000W-LED-SS-480V Page: 1 The GAU-HB-1000W-LED-SS-480V from Larson Electronics is an LED Crane

More information

HID/AREA: NEC/CEC EXPLOSIONPROOF. Applications. NEC/CEC Certifications and Compliances

HID/AREA: NEC/CEC EXPLOSIONPROOF. Applications. NEC/CEC Certifications and Compliances Integrally Ballasted. 50 W, 70 W, 100 W, 150 W, 250 W, 400 W HPS; 175 W, 250 W, 320 W, 350 W, 400 W PSMH; 175 W, 250 W, 400 W MH. Applications Ideal for use in chemical and petrochemical plants, such as

More information

Technical Information Guide

Technical Information Guide Revised 09/1/08 Technical Information Guide www.sunlightsupply.com www.nationalgardenwholesale.com IMPORTANT PRODUCT INFORMATION READ IMMEDIATELY KEEP ORIGINAL PACKAGING ALL RETURNS NEED TO BE IN THE ORIGINAL

More information

ConstantColor CMH Supermini Ultra

ConstantColor CMH Supermini Ultra GE Lighting ConstantColor CMH Supermini Ultra New Generation of Single Ended Ceramic Metal Halide Lamps 35W DATA SHEET Product information GE s low watt CMH lamps have opened new possibilities for lighting

More information

150W Explosion Proof Telescoping Anodized Aluminum Pole Mount LED Light Tower ' -Surface Mount

150W Explosion Proof Telescoping Anodized Aluminum Pole Mount LED Light Tower ' -Surface Mount 150W Explosion Proof Telescoping Anodized Aluminum Pole Mount LED Light Tower - 5-12' -Surface Mount Part #: EPL-APM-150LED-RT Page: 1 Made in the USA The EPL-APM-150LED-RT Telescoping Pole Mounted Explosion

More information

G1-24. Applications UL listed for marine type electric fixtures--outside. Ideal in Class I, Div. 1 and 2 installations

G1-24. Applications UL listed for marine type electric fixtures--outside. Ideal in Class I, Div. 1 and 2 installations 1-24 Applications UL listed for marine type electric fixtures--outside type (salt water). Ideal in Class I, Div. 1 and 2 installations in refineries, pipeline transportation facilities; at drilling rigs

More information

C1D1 Explosion Proof 25 Watt High Bay LED Light Fixture - Paint Spray Booth Approved - 2,167 Lumens

C1D1 Explosion Proof 25 Watt High Bay LED Light Fixture - Paint Spray Booth Approved - 2,167 Lumens C1D1 Explosion Proof 25 Watt High Bay LED Light Fixture - Paint Spray Booth Approved - 2,167 Lumens Part #: EPL-HB-25LED-RT Page: 1 The Larson Electronics EPL-HB-25LED-RT Explosion Proof High Bay light

More information

156W Explosion Proof Portable LED 360 Degree Flood Low Profile Light System - 2ft - Tank Cleaning

156W Explosion Proof Portable LED 360 Degree Flood Low Profile Light System - 2ft - Tank Cleaning 156W Explosion Proof Portable LED 360 Degree Flood Low Profile Light System - 2ft - Tank Cleaning Part #: EPL-360-3XLP24-LED-V2-100 Page: 1 Made in Texas The EPL-360-3XLP24-LED-V2-100 Portable Explosion

More information

Applications. Standard Materials. Certifications and Compliances

Applications. Standard Materials. Certifications and Compliances Code Master 2 HID Factory Sealed Luminaires Class I, Division 1 and 2, Groups C, D Class I, Division 1 and 2, Groups B, C, D Applications Ideal for use in chemical and petrochemical plants, such as manufacturers

More information

INDUCTION FLUORESCENT LAMPS are one of the oldest energy saving lighting technologies in

INDUCTION FLUORESCENT LAMPS are one of the oldest energy saving lighting technologies in INDUCTION FIXTURES INDUCTION OVERVIEW INDUCTION FLUORESCENT LAMPS are one of the oldest energy saving lighting technologies in existence with many years of positive field test results and which has recently

More information

ConstantColor CMH Tubular Clear

ConstantColor CMH Tubular Clear GE Lighting ConstantColor CMH Tubular Clear Ceramic Metal Halide Lamps 70W, W and 150W DATA SHEET Product information ConstantColor CMH lamps combine the HPS technology (providing stability, efficiency

More information

LEDMPALPRO LED Area Luminaire

LEDMPALPRO LED Area Luminaire CATALOG NUMBER: NOTES: FIXTURE TYPE: PROJECT: FEATURES DIMENSIONS 2 ¾ 12 ⅝ 1 ⅝ Weight: 8.2 lbs. (8W), 1.8 lbs. (1W) & 11 lbs. (14W) PRODUCT DESCRIPTION The LEDMPALPRO series is a group of premium architectural

More information

Solid State T8 tube is the smart alternative to a

Solid State T8 tube is the smart alternative to a Solid State T8 tube Ideal for decorative and ambient lighting in retail outlets, hotels, restaurants, government buildings, and multi-unit residences L Prize Winner Solid State T8 tube Direct Replacement

More information

31 SERIES Modular area fixtures. Replaces: 1000W HID

31 SERIES Modular area fixtures. Replaces: 1000W HID Replaces: 1000W HID Product Life: 75,000 hours Optic Lens: Borosilicate Glass 31 SERIES Modular area fixtures Neptun's LED parking lot /area fixtures combine architectural form and versatility to make

More information

ConstantColor CMH MR16 Ultra

ConstantColor CMH MR16 Ultra GE Lighting ConstantColor CMH MR16 Ultra New Generation of Reflector Ceramic Metal Halide Lamps 35W DATA SHEET Product information GE s low watt CMH lamps have opened new possibilities for lighting design,

More information

BL7000 SYSTEM OPERATING MANUAL

BL7000 SYSTEM OPERATING MANUAL BL7000 SYSTEM OPERATING MANUAL REV 2.0 208 / 230V COPYRIGHT 1995 Xenotech, Inc. PAGE 1 POWER INPUT CONNECTOR WIRING INSTRUCTIONS THE INPUT POWER REQUIREMENTS FOR A 7 KW POWER SUPPLY ARE AS FOLLOWS. VOLTAGE

More information

Product Description MHN-TD. Benefits. Features. Application. Versions. Double-ended quartz Metal-halide lamp

Product Description MHN-TD. Benefits. Features. Application. Versions. Double-ended quartz Metal-halide lamp Lighting Product Description MHN-TD Double-ended quartz Metal-halide lamp Benefits All types are UV-Block for reduced health and fading risks Features Quartz discharge tube containing high-pressure mercury

More information

HOW IS LIGHT PRODUCED

HOW IS LIGHT PRODUCED HOW IS LIGHT PRODUCED The fluorescent lamp produces light by the passage of an electric current flowing through a vapor of mercury. 1.Electron emitted from electrode collides with mercury atom. 2.Impact

More information

Product Description. MASTER PL-S 2 Pin

Product Description. MASTER PL-S 2 Pin Product Description MASTER PL-S 2 Pin Energy-saving compact fluorescent lamps Compact long-arc low-pressure mercury discharge lamp Envelope consists of 2 parallel narrow fluorescent tubes Benefits Optimal

More information

304 Series LED Recessed Canopy Luminaires

304 Series LED Recessed Canopy Luminaires CAN-304-PS-RS " 6.6" [ 155mm ] [ 169mm ] Notes: 14.0" SQ [ 356mm ] Cut Out Luminaire Clearance Product Family Optic Mounting # of LEDs LED Voltage Color Drive Factory-Installed Options ( x 10 ) Series

More information

Applications. Standard Materials. Certifications and Compliances

Applications. Standard Materials. Certifications and Compliances Code Master 2 HID Factory Sealed Luminaires NEC: Class I, Division 1 and 2, Groups C, D Class II, Division 1 and 2, Groups E, F, G Marine Type Electric Fixtures Outside Type (Salt Water) Class I, Division

More information

ConstantColor CMH Mini G8.5

ConstantColor CMH Mini G8.5 GE Lighting ConstantColor CMH Mini G8.5 Single Ended Ceramic Metal Halide Lamps 2W, and 7W DATASHEE T Product information ConstantColor CMH lamps combine HPS technology (providing stability, efficiency

More information

Super-high output LED high bay. Affordable replacement for up to 400W HID. RAIL RCLIGHTING.CA

Super-high output LED high bay. Affordable replacement for up to 400W HID. RAIL RCLIGHTING.CA Super-high output LED high bay. Affordable replacement for up to 4W HID. RAIL RCLIGHTING.CA 888 7- High Bay RAIL Affordable LED replacement with up to 4W HID equivalency Ideal for large spaces at mounting

More information

Standard Grade 23 Inch Reflector/Refractor. Ordering Information. series wattage source voltage optics color options options BL-LB1

Standard Grade 23 Inch Reflector/Refractor. Ordering Information. series wattage source voltage optics color options options BL-LB1 Job Type Dimensions Specifications B A C NRTL/C Damp Location D Slick-On Quick-On E A B C D E 9-1/2" 2" 9-1/2" 26-11/16" 23-1/8" 241 mm 51 mm 241 mm 678 mm 587 mm 9-1/2" 1-1/8" 8-5/8" 25-13/16" 23-1/8"

More information