Proportional solenoid flow control valves EPF(R)G
|
|
- Malcolm Foster
- 5 years ago
- Views:
Transcription
1 Proportional solenoid flow control valves EPF(R)G his valve is a flow control valve which utilizes a proportional solenoid actuator. proprietary flow adjustment design is incorporated to allow very precise positioning of the main spool. his flow control valve is pilot operated, and the main spool is impervious to effects of flow forces and other disturbances. he EPFRG valve utilizes a bypass type pressure compensator with load sensing function which contributes to energy saving of hydraulic circuits. Functional Symbols EPFG-** EPFG-**-F - EPFRG-**-S EPFRG-**-F-S V V P P Note: EPFRG-/ has no V ports (vent). Model Code E PF( R )G - - -( F )-( E )- -( S ) 7 Proportional solenoid flow control valve (gasket mounting) EPFG: with series type pressure compensator EPFRG: with bypass type pressure compensator Size Refer to Specifications. Max. control flow Refer to Specifications. Position sensor Omit: no position sensor F: with position sensor Pilot Omit: internal pilot with reducing valve E: external pilot with reducing valve Design no. : all except EPFRG- : EPFRG- 7 Control code Omitted for EPFG S: for EPFRG
2 Specifications 形 Model Code 式 EPFG EPFRG 大きさの呼び Size 最高使用圧力 Max. working pressure MPa 7. 最大制御記号 Max. control flow code 最小制御 Min. control flow 最大制御 Max. control flow パイロット圧力 Pilot Pressure MPa.~ パイロット Pilot flow 定 Rated 格 current 電 流 コCoil イresistance ル抵 抗 Ω ディザ周波数 Dither frequency Hz ~ デDither ィcurrent ザ電 流 m rms 9 Current 電流制御形 control ヒステリシス Hysteresis % % 以下 or Less* ソレノイド solenoid 使用の場合 Repeatability 繰返し性 % % 以下 or Less* Position 位置制御形 control ヒステリシス Hysteresis..% % 以下 or Less* ソレノイド solenoid 使用の場合 Repeatability 繰返し性..% % 以下 or Less* 圧 Pressure 力補 compensator 償弁 シリ-ズ形圧力補償弁 Series type* バイパス形圧力補償弁 ypass type* 質 Weight kg Note: *: Value when using controller P-- or equivalent. *: Value when using controller P-Z- or equivalent. *: Valve unit value using special controller and with same working conditions. *: Capacity of EPFRG- pressure compensator is. For flow control above, pressure compensator function will deteriorate if load pressure is below MPa. *: For optimum flow control, maintain valve pressure differential over MPa for size, over. MPa for size, and over MPa for size. Characteristics Curve (at mm /s) (typical examples) Input Current Flow Characteristics EPFG-/EPFRG- EPFG-/EPFRG- EPFG-/EPFRG- 流 EPFG- EPFRG- Input 入力電流 current m m Input Voltage Flow Characteristics 流 EPFRG- Input 入力電圧 voltage VV EPFG- 流 流 EPFG- EPFRG- Input 入力電流 current m m EPFRG- EPFG- Input 入力電圧 voltage VV 流 EPFG- EPFRG- Input 入力電流 current m m EPFG---F/EPFRG---F EPFG---F/EPFRG---F EPFG---F/EPFRG---F 入力電圧 Input voltage V V - Connector EPFG- EPFRG- Connector Solenoid * No polarity for teral, DIN connector pin layout Proportional solenoid electrical wiring diagram
3 Characteristics Curve (at mm /s) (typical examples) Step Response Characteristics Input 入力電流 current EPFRG-.sec Input 入力電流 current EPFRG- 9.sec 7 Input 入力電流 current EPFRG-.sec Input 入力電流 current EPFRG-.sec - Notes on Operation Mounting orientation Valve can be mounted in any direction. However if valve is mounted on the lateral side of the manifold block, and none of the air bleed plugs do not face the ceiling, rotate the proportional solenoid 9 to orient an air bleed plug to the ceiling. Current-flow characteristics may vary slightly (approx..%) according to the mounting direction. ir bleed For stable flow control, loosen the air bleed plug and bleed air completely out of the valve prior to use. Manual operation In case there is no input current to the solenoid during initial adjustment or electric malfunction, press the manual pin for flow control such as Inching. Mounting olts (IS 7, Strength Class.9) Valve 弁形式 Model 六角穴付きボルト Hex Socket olts Metric メ-トルねじ hread Unified ユニファイねじ hread 本数 Qty EPFG- M /-UNC. EPFG- M /-UNC. EPFG- M /-UNC. EPFRG- M 7 /-UNC 9. EPFRG- EPFRG- EPFRG- M M M 9 /-UNC. M 9 M M /-UNC 9. Mounting bolts must be ordered separately. Mounting bolt tightening torque EPFG-, EPFRG-: to N m EPFRG-: 7 to N m EPFG-: 9 to N m EPFRG-, EPF(R)G-: to 9 N m Zero adjustment his is adjusted at factory before shipment. Readjustment is not necessary. Drain piping allowable back pressure is. MPa. Piping should be directly returned to tank. Ensure that end of the piping is always below the fluid level. Valve and actuator piping Care should be paid when the vent line piping is long as the large volume of fluid in the pipes may cause instability (resonation). Piping should be as short as possible. For optimum flow control, differential pressure should be more than or equal to the values shown in the below table. 大きさの呼び Size Valve Differential 弁差圧 Pressure MPa MPa. Subplate Valve 弁形式 Model サブプレ Subplate -ト形式 Connection 接続口径 Port Dia. Rc Rc Valve 弁取付けねじ Mounting hread EPFG- EPFGM-- / EPFGM-Z- EPFGM-- EPFG- EPFGM-- -/ ユニファイねじ Unified thread EPFGM-Z- -/ EPFG- FGM-- -/ FGM-- EPFRG- D-FRGM-- / EPFRG- D-FRGM-- -/ メMetric -トルねじ thread EPFRG- D-FRGM-- -/ Subplate must be ordered separately. Hex socket bolts for mounting valve included (See above table for thread types.) See page R- and R-9 for dimensions.
4 Dimensions EPFG- port (pilot).. Wiring port (DIN connector) Cable gland Pg. Wire diameter φ~9 -M, deep -φ7., 7.9 deep -φ. -φ7 -φ hole φ7. counterbore depth port port Manual override pin φ... indicated by dotted line (φ) ir bleed plug ( locations) (Hex socket bolts,. across flats) pprox... EPFG- -φ7 hole φ counterbore depth port.. 9 port 9 -φ. locating pin φ φ7 79. Manual override pin φ. Wiring port (DIN connector) Cable gland Pg. -M, deep Wire diameter φ~9 -φ., deep port (pilot) -M, deep (for eye-bolt) indicated by dotted line (φ). ir bleed plug ( locations) (Hex socket bolts,. across flats) pprox.. 9 -φ. locating pin
5 Dimensions EPFG- -φ hole φ counterbore depth port port Wiring port (DIN connector) Cable gland Pg. -M, deep Wire diameter φ~9 -φ9., 7.9 deep. -φ M, deep (for eye-bolt). Manual override pin φ port (pilot).. 9 indicated by dotted line (φ) φ. ir bleed plug ( locations) (Hex socket bolts,. across flats). -. -φ9 locating pin.. pprox EPFRG- -φ hole φ7. counterbore depth port (pilot) P port V port (vent) Wiring port (DIN connector) Cable gland Pg., wire diameter φ to 9 -M, deep -φ 7.. ir bleed plug ( locations) indicated by dotted line (φ). (Hex socket bolts,. across flats) 9 -φ7. P V φ Manual override pin φ. port port pprox. 9.
6 Dimensions EPFRG- -φ hole φ counterbore depth port (pilot) 7.. P port Wiring port (DIN connector) Cable gland Pg., wire diameter φ to 9 -M, deep -φ7, deep -φ 7 -φ 7.. Manual override pin φ... port.. V port (vent) port ir bleed plug ( locations) (Hex socket bolts,. across flats) P V Drain pressure acts on area in circle indicated by dotted line (φ). pprox.... -φ locating pin 7 - EPFRG- 9 -φ hole φ counterbore depth port (pilot) 7.. Manual override pin φ port P port Wiring port (DIN connector) Cable gland Pg., wire diameter φ to 9 -M, deep -φ -φ, deep M, deep (for eye-bolt) port. ir bleed plug ( locations) (Hex socket bolts,. across flats) indicated by dotted line (φ). -φ P Note: his model has no V port (vent). Consult okyo Keiki if vent port is required. 7 pprox.. 9 -φ locating pin
7 Dimensions EPFRG- -φ hole φ counterbore depth P port Wiring port (DIN connector) Cable gland Pg., wire diameter ø to 9 -M, deep 7 -φ, deep -φ 9 -φ. port (pilot) port P Manual override pin φ M, deep (for eye-bolt) port ir bleed plug ( locations) (Hex socket bolts,. across flats) Drain pressure acts on area in circle indicated by dotted line (φ7) Note: his model has no V port (vent). Consult okyo Keiki if vent port is required. -7 pprox. Construction EPFG φ locating pin O-ring 照号 No. 部品番号 Part No. Standard 規格 個数 Qty 799 S-(NR,Hs9) 799 S-(NR,Hs9) 799 S-(NR,Hs9) 7977 S-7(NR,Hs7) 799 S-(NR,Hs9) S-(NR,Hs9) 7999 S-9(NR,Hs9) 799 S-(NR,Hs9) S-(NR,Hs9) 799 S-(NR,Hs9) 799 S-(NR,Hs9) 799 S-(NR,Hs9) 7999 S-9(NR,Hs9) 799 S-(NR,Hs9)
8 Construction EPFRG-// EPFRG-/ 7 9 O-ring EPFRG- EPFRG- 照号 No. 部品番号 Part No. Standard 規格 個数 Qty 照号 No. 部品番号 Part No. Standard 規格 個数 Qty 799 S-(NR,Hs9) 799 S-(NR,Hs9) 799 S-(NR,Hs9) 799 S-(NR,Hs9) 799 S-(NR,Hs9) 7979 S-7(NR,Hs9) 799 S-(NR,Hs9) 799 S-(NR,Hs9) 799 S-(NR,Hs9) 799 S-(NR,Hs9) 799 S-(NR,Hs9) 799 S-(NR,Hs9) 799 S-(NR,Hs9) S-(NR,Hs9) S-(NR,Hs9) S-7(NR,Hs7) S-7(NR,Hs7) S-9(NR,Hs9) S-(NR,Hs9) 799 S-(NR,Hs9) 799 S-(NR,Hs9) 7979 S-7(NR,Hs9) 799 S-(NR,Hs9) S-(NR,Hs9) S-(NR,Hs9) EPFRG- 照号 No. 部品番号 Part No. Standard 規格 個数 Qty 799 S-(NR,Hs9) 799 S-(NR,Hs9) 799 S-(NR,Hs9) 7999 S-9(NR,Hs9) 799 S-(NR,Hs9) 799 S-(NR,Hs9) 799 S-(NR,Hs9) S-9(NR,Hs9) S-7(NR,Hs7) 9 9 IS -G 7999 S-9(NR,Hs9) 799 S-(NR,Hs9) S-(NR,Hs9) EPFRG
9 Construction EPFG-/ 7-9 O-ring EPFG- EPFRG O-ring 7 9 EPFG 照号 No. 部品番号 Part No. Standard 規格 個数 Qty 照号 No. 部品番号 Part No. Standard 規格 個数 Qty 799 S-(NR,Hs9) 799 S-(NR,Hs9) 799 S-(NR,Hs9) 799 S-(NR,Hs9) 799 S-(NR,Hs9) 799 S-(NR,Hs9) 799 S-(NR,Hs9) 7979 S-7(NR,Hs9) S-7(NR,Hs7) S-7(NR,Hs7) 799 S-(NR,Hs9) 799 S-(NR,Hs9) 799 S-(NR,Hs9) 799 S-(NR,Hs9) S-7(NR,Hs9) S-(NR,Hs9) 799 S-(NR,Hs9) 799 S-(NR,Hs9) 7999 S-9(NR,Hs9) 799 S-(NR,Hs9) S-7(NR,Hs9) S-(NR,Hs9) 799 S-(NR,Hs9) 799 S-(NR,Hs9) 9 9 照号 No. 部品番号 Part No. Standard 規格 個数 Qty 799 S-(NR,Hs9) 799 S-(NR,Hs9) 799 S-(NR,Hs9) 799 S-(NR,Hs9) 7979 S-7(NR,Hs9) S-(NR,Hs7) S-9(NR,Hs9) 799 S-(NR,Hs9) S-(NR,Hs9) 799 S-(NR,Hs9) 799 S-(NR,Hs9) 799 S-(NR,Hs9) 799 S-(NR,Hs9)
Proportional solenoid relief valves EPCG2-03/06/10
roportional solenoid relief valves ECG-// Functional Symbol X Y his valve utilizes a proportional solenoid actuator to provide proportional control of hydraulic circuit pressure. Model Code - ECG---Y-L-
More informationHigh torque low speed vane motors (multi-torque type) MHT
High torque low speed vane motors (multi-torque type) MHT Functional Symbols Special switching valves enables easy switching from low speed high torque to high speed low torque. alanced type vane motor
More informationSolenoid operated directional control valves with spool position monitoring DG4V-3-SW
Solenoid operted directionl control vlves with spool position monitoring DG4V-3-SW 3- Directionl Control Vlves Model Code DG4V-3-(L)-M-SW---7-(8)-54 3 4 5 6 7 8 9 hese operted directionl control vlves
More informationMiniature solenoid directional valves
Miniture solenoid directionl vlves - Model Code Compct solenoid directionl vlve for use up to mx. M. Resin molded, 5/6 Hz dul frequency, two terminl coils do not require rewiring for differing frequencies.
More informationSolenoid controlled pilot operated directional control valves DG5S-10
Solenoid controlled pilot operted directionl control vlves DGS- - Model Code ( F )- D G S - - A( L )-( )( )-( T )- P - T - - JA - M 7 Hydrulic fluid Omit: minerl oil sed fluid, wter-glycol sed fluid F:
More informationLow noise, high pressure variable displacement piston pumps PH series
1-1 Low noise, high pressure variable displacement piston pumps PH series The PH Series is a low-noise variable displacement piston pump with rated pressure of 28 MPa. This series was developed based on
More informationSolenoid controlled pilot operated directional control valves DG5V-7/DG5V-H8
Solenoid controlled pilot operted directionl control vlves DGV-7/DGV-H8 Solenoid pilot operted directionl vlves incorporte DGV-- design pilot vlves. - Model Code ( F )- D GV - 7 - ( L )-( )-( )-( )- 7
More informationSwitches and sensors. Page
Switches and sensors Pressure Switch, SG1/ST1-0 Pressure Switch, SG-3 Electronic Pressure Switch, ESP Pressure Sensor (Press. Transmitter), ETP Pressure Monitor, TXS Page 4 6 10 1 H 1 SWITCHS CARTRIDGE
More informationSolenoid operated directional control valves DG4V-5, 40
Solenoid operted directionl control vlves DG4V-5, 4 Model Code (F3)-DG4V-5-(L)-M-7L--6-4-(8) 1 3 4 5 6 7 8 9 1 11 1 Hydrulic fluid Omit: minerl oil sed fluid, wter-glycol sed fluid F3: hosphte ester Solenoid
More informationReplacement of Monitor Unit
MU-190/MU-231 (Tabletop Mount or Bracket Mount) Replacement of Monitor Unit The purpose of these instructions is to provide the procedures for the replacement of the monitor unit MU-201C and MU-231C, which
More informationProportional Valve.
Proportional Valve Electro-Hydraulic Proportional Pilot Relief Valve Electro-Hydraulic Proportional Flow & Directional Control Valve Electro-Hydraulic Proportional Relief & Flow Control Valve Electronic
More informationMC-COSR-3/MC-COSR-16
172-65185A-08 ( Multi-control Valve) 20 November 2014 ISO 9001/ ISO 14001 Manufacturer Kakogawa, Japan is approved by LRQA LTD. to ISO 9001/14001 High-precision Multi-control Valve for Steam -3/-16 Actuator:
More informationMax. Reversed Free Flow. Max. Operating. Pressure MPa (PSI) Fine Feed 20 (5.3) 14 (2030) 40 (10.6) ( ) 40 (10.6) (
These valves are the combination of flow control valve, a deceleration valve and a check valve and used mainly for controlling rapid traverse and feed cycles machine tools. Switching from rapid traverse
More informationProportional Electro-Hydraulic Relieving and Reducing Valves
These valves consist of a small size but high performance EH series electro-hydraulic proportional pilot relief valve and reducing valve with relief function. The valves control the system pressure proportionally
More informationCertificate of Accreditation
PERRY JOHNSON LABORATORY ACCREDITATION, INC. Certificate of Accreditation Perry Johnson Laboratory Accreditation, Inc. has assessed the Laboratory of: Toyo Tire Corporation Product Development Division
More informationDirect Operated Type Solenoid Operated Proportional Throttle Valve
Direct Operated ype Solenoid Operated roportional hrottle Valve EM-G EM-G3 EM-G3-X EMS-2 EMS-2 EM-G4 b X EMS-3 Features hese proportional throttle directional control valves perform spool position feedback
More information製品仕様書 PRODUCT SPECIFICATION
KYOCERA Connector Products Corporation 製品仕様書 PRODUCT SPECIFICATION 6806 シリーズ Spec.No.201-03-1148 1. 品名 FPC/FFC CONNECTOR 2. 形式 0.5 mm PITCH FPC/FFC CONNECTOR (Au PLATED) 3. 適用範囲 Scope 本仕様書は 6806 シリーズコネクタの組立製品の仕様に適用する
More informationDirect Operated Type Solenoid Operated Proportional Throttle Valve
efore using the product, please check the For latest information, DF catalogs and operation manuals Direct Operated ype Solenoid Operated roportional hrottle Valve EM-G EM-G3 EM-G3-X EMS-2 EMS-2 EM-G4
More informationSolenoid Pilot Operated Proportional Directional Control Valve
Solenoid Pilot Operated Proportional Directional Control Valve Features hese solenoid pilot operated proportional directional control valves use a nozzle flapper valve as pilot valve and perform spool
More informationPROPORTIONAL ELECTRO-HYDRAULIC CONTROLS
H PROPORTIONAL ELECTRO-HYDRAULIC CONTROLS Hydraulic Controls H-3 H-1 E Series Hydraulic Controls Hydraulic Controls Max. Maximum Flow Types KS Graphic Symbols Operating L/min 1 2 3 5 10 20 30 50 100 200
More informationDAIKIN PMC. Energy-saving Hybrid Hydraulic System SUPER UNIT. Development to General Industrial Machinery
Energy-saving Hybrid Hydraulic System SUPER UNIT Development to General Industrial Machinery Development of Energy-saving Hybrid Hydraulic System to General Industrial Machinery For machining tool market:
More informationHydraulic Fluids. Note: For use with hydraulic fluids other than those listed above, please consult your Yuken representatives in advance.
Hydraulic Fluids Fluid Types Any type of hydraulic fluids listed in the table below can be used. Petroleum base oils Use fluids equivalent to ISO VG 32 or VG 46. Use phosphate ester or polyol ester fluid.
More informationROTARY TYPE TORQUE SENSOR OPERATING INSTRUCTION
ROTARY TYPE TORQUE SENSOR MODEL TCR OPERATING INSTRUCTION To Users To use this product properly and safely, please read this operating instruction carefully before use. If you have any question about the
More information1. 適用範囲 2. 定義 3. 認可申請 4. 認可 5. 第 I 部 : 電気安全に係る車両の要件 6. 第 II 部 : 安全に係る充電式エネルギー貯蔵システム (REESS) の要件 7. 型式認可の変更及び拡大 8. 生産の適合性 9. 生産の不適合に対する罰則 10.
UN-R136-00 (2016.1.20) Regulation No. 136 Uniform provisions concerning the approval of category L with regard to specific requirements for the electric power train Contents Regulation 1. Scope 2. Definitions
More informationPilot Operated Flow Control Valves / Pilot Operated Flow Control and Check Valves
FLOW CONTROLS Flow control of these valves is continuously made by a hydraulically operated pilot piston mechanism which controls opening area of the orifice of the valve. With the use of these valves,
More informationPROPORTIONAL VALVES SERVO VALVES. Maximum operating pressure MPa {kgf/cm 2 } Model [Model No.]
J PROPORTIONAL VALVES SERVO VALVES J Model [Model No.] Solenoid pilot operated proportional relief valve [JRP] Solenoid operated proportional relief valve [JRPL] Type C2 solenoid operated proportional
More informationIntelligent Recharger
Intelligent Recharger ユーザマニュアル User Manual HB-UM-IR-1009-01 Intelligent Recharger User Manual 目次 Table of contents 1. はじめに 2 Introduction 2. 製品概要 3 Board Specification 3. 機能説明 5 Features 4. ボードおよび充電パラメータのプログラミング
More informationA Series Variable Displacement Piston Pumps. A16 Type performance characteristics A16 Type Noise level characteristics.
EIC--12- PISTON PUMPS Series Variable Features High efficiency Under the conditions of pressure 16 Kgf/cm² and speed 18 r/min. volumetric efficiency is over 98% and the overall efficiency is over 9%. Low
More informationProduct List 製品一覧. Surface Mount Type LED. Top Emitting Type. 072 Automotive NJSW170C NEW
Product List 製品一覧 パッケージ Package 色度座標 Chromaticit Coordinate (,) 光度エ v (mcd) 光束 φv (lm) 順電圧 V F Ma. 指向特性 Directivit 2θ1/2 (degree) 熱抵抗逆電流 Rjs エ R Ma. ( /W) (μa) P 1 絶対最大定格 Absolute Maimum Ratings エ R P
More informationProportional Electro-Hydraulic Directional and Flow Control Valves
Proportional Electro-Hydraulic s These valves are double-deck directional and flow control valves employing as their pilot the electro-hydraulic proportional pressure reducing valves with two proportional
More informationAFLAS 400E/ AFLAS 600S High-performance fluoro-elastomer having excellent crosslinking properties AFLAS 400E/ AFLAS 600S
/ AFLAS 600S High-performance fluoro-elastomer having excellent crosslinking properties / AFLAS 600S 1. 1.1. Fig. 1 Fig. 2. Various kinds of Fluoro-elastomers. 1.2. AGC AFLAS Fig. 3 Fig. 1. Positioning
More informationA Series Variable Displacement Piston Pumps
A Series Variable Displacement Piston Pumps A37 A56 A1637 A16 A10 A Series Variable Displacement Piston Pumps Pump Type Graphic Symbol Geometric Displacement cm 3 /rev 1 5 10 0 50 100 00 300 Maximum Operating
More informationPilot Operated Pressure Relief Valve Series R5V (Denison)
Characteristics Pilot operated pressure relief valves series R5V have a similar design to the subplate mounted R4V series. The SAE flanges allow to mount the valves directly on the outlet flanges of pumps
More informationPROPORTIONAL ELECTRO-HYDRAULIC CONTROLS
H PROPORTIONAL ELECTRO-HYDRAULIC CONTROLS Hydraulic Controls H-3 H-1 E Series Hydraulic Controls Hydraulic Controls Max. Maximum Flow Types KS Graphic Symbols Operating L/min 1 2 3 5 10 20 30 50 100 200
More information3 Port Solenoid Valve Direct Operated Poppet Type. Body type. Body ported. Manifold. Valve option
Port Solenoid Valve Direct Operated Poppet ype Series V17 Rubber Seal [Option] Compact yet provides a large flow capacity Dimensions (W x H x D) 45 x 89.5 x 45 (Grommet) C:.6 dm /(s bar) (Passage ) Suitable
More informationEManually Operated Directional Valves
DIRECIONL CONROLS hese valves may be used to manually shift the spool position and change the direction of oil flow. hreaded Connections Sub-late Mounting Specifications DM--C - DM--D - DM--D - DM-- -
More informationディーゼル機関仕様書 ENGINE SPECIFICATIONS. 公式呼称 4LE1(Stage 3A / Interim Tier4) 社内呼称 AV-4LE1NYBW-04 Model No. EXPORT
No. IS-08-017-0 ( 1/9 ) 経歴 Rev. ディーゼル機関仕様書 ENGINE SPECIFICATIONS 0 機関型式 Engine Model 納入先 Customer 搭載機種 Application 公式呼称 4LE1(Stage 3A / Interim Tier4) Base Model 社内呼称 AV-4LE1NYBW-04 Model No. 一般輸出 EXPORT
More informationRS SERIES. Features. RS シリーズは ターミナルサイズが2.3mm で構成されており 各種の制御回路並びに低パワー回路に対応することができます RS 標準タイプコネクタは コネクタの半嵌合が起きにくい慣性ロック方式です ( 慣性ロック方式でないコネクタが一部あります )
RS SERIES Features RS series consists of a 2.3mm type classified according to terminal size, supporting use in a variety of control circuits and low power circuits. The RS-standard type connectors adopt
More informationProportional Electro-Hydraulic Flow Control and Relief Valves
Ω Ω Proportional Electro-ydraulic Flow ontrol and Relief Valves This flow control and relief valve is an energy-saving valve that supplies the minimum pressure and flow necessary for actuator drive. Since
More informationProportional Electro-Hydraulic Pilot Relief Valves
Proportional Electro-Hydraulic This valve consists of a small DC solenoid and a direct-acting relief valve. It serves as a pilot valve for a low flow rate hydraulic system or a proportional electro-hydraulic
More informationCircuit of directional control valve and regulator. Simplifying circuit design. Space saving and piping. work eliminated. Automating pressure control
Port Electro-Pneumatic Proportional Valve Series 000/000 Capable of actuating a cylinder and performing analog control of pressurization alone can be used to switch and actuate a cylinder and to perform
More informationSeries Shockless Type Solenoid Controlled Pilot Operated Directional Valves
Solenoid Controlled ilot Operated Directional Valves Electronic Circuit X Specifications Descriptions G-DSHG-4-3C - - - -/9 G-DSHG-6-3C - - - -/9 Max. Flow /min (U.S.GM) 16 (4.3) (66.1) 1 1 Max. Operating
More informationPubl. 3-EN 2950-A. DENISON HYDRAULICS Pressure Relief Valve R6V
Publ. 3-EN 2950-A DENISON HYDRAULICS Pressure Relief Valve R6V FEATURES, SYMBOL FEATURES High Performance: R6V valves are designed for a maximum pressure of 350 bar and a flow capacity up to 650 l/min.
More informationHigh Pressure, High Flow Rate Modular Valves
High Pressure, High Modular Valves EIC-F-14- MODULR VLVES The modular valves are functional elements with which a hydraulic system can be composed and built easily by stacking them with the mounting bolts.
More informationInstructions for how to fill out the Arai Auto Auction
Instructions for how to fill out the Arai Auto Auction Passenger Vehicle Auction Entry Form (Digital Format Use) As of December, 2016 Note: Please fill in the form in Japanese language only. Other languages,
More informationSeries Proportional Electro-Hydraulic Controls
Proportional Electro-ydraulic Controls Types Graphic Symbols Max. Operating Pressure () Maximum Flow U.S.GPM. 3 3 3 L/min Page Pilot Relief Valves. (3) EDG 67 Relief Valves. (3) EBG 3 6 676 Relieving and
More informationTOWA SEIDEN INDUSTRIAL CO., LTD.
INSTRUCTION MANUAL CAPACITANCE TYPE LEVEL SENSORS MODEL: CA Meanings of indications for safety used in this Instruction Manual are as follows. WARNING: Indicates that improper handling assumes the risk
More informationProportional Electro-Hydraulic Flow Control (and Check) Valves
Proportional Electro-Hydraulic Flow Control (and Check) Valves EH SERIES The system flow rate can be controlled remotely as desired by regulating input voltage. Further, since pressure and temperature
More information"G" SERIES SHOCKLESS TYPE SOLENOID OPERATED DIRECTIONAL VALVES G-DSG-01/03 (1/8, 3/8) "G" SERIES SHOCKLESS TYPE
"G" SRIS SHOCKLSS Y NOID ORD DIRCIL VLVS G-DSG-1/3 (1/, 3/) "G" SRIS SHOCKLSS Y NOID CROLLD ILO ORD DIRCIL VLVS G-DSHG-/ (1/, 3/) Mounting Up to 5 Ma (33 SI), 5 L /m in (.1 U.S.GM) ub. C-5 DIRCIL CROLS
More information協定規則第 19 号動力駆動車両用前部霧灯の認可に関する統一規定目次協定規則緒言適用範囲
Regulation No.19 Uniform provisions concerning the approval of power-driven vehicle front fog lamps contents Contents Regulation Introduction Scope 1. Definitions 2. Application for approval 3. Markings
More informationAirflow Tester. Features. Measurement Functions. Specifications
Airflow Tester Features (Patented as a movable measurement device for measuring device airflow and system impedance) Enables the selection of the optimal fan for a device An optimal fan for a device can
More information3 Port Solenoid Valve Direct Operated Poppet Type 02 1 G VT325. For manifold: Enter VO. Valve option. Nil Standard V For vacuum Option.
3 Port Solenoid Valve Direct Operated Poppet Type Series VT325 Rubber Seal [Option] Note) Applicable only for DIN terminal type. Compact yet provides a large flow capacity Dimensions (W x H x D) 55 x 118
More informationCartridge Valves Technical Information Directional Valves DCV 03
OVERVIEW DCV 03 directional control valves consist of: housing (1), control spool (5), with two centering springs (4), and cylindrical operating solenoids (2, 3). The three-position directional valves
More informationMax. Reversed Free Flow L/min
These Valves are the combination of flow control valve, a deceleration valve and a check valve and used mainly for controlling rapid traverse and feed cycle in machine tools. Switching from rapid traverse
More informationFLOW CONTROLS. Maximum Flow U.S.GPM Maximum Operating Pressure MPa (PSI) Graphic Symbols. Page. Valve Type.
FLOW CONTROLS Valve Type Graphic Symbols Maximum Operating Pressure MPa (PSI) Maximum Flow U.S.GPM 5 5 5 5 5 5 5 Page Flow Control Valves (5) 77 Flow Control and Check Valves (5) 77 Pilot Operated Flow
More informationPilot Operated 2 Port Solenoid Valve for Dry Air
Pilot Operated Port Solenoid Valve for Dry ir VQ0/30 Series Compact and lightweight with large flow capacity [Option] VQ0 Weight (g) 46 80 C [dm 3 /(s bar)].5 (C8) 3.0 (C) Series VQ0 Series VCH VDW SX0
More information29 158/ Proportional Pressure Relief Valve Models DBE and ZDBE, Series 1X. Ordering code DBE 6 1X G24 1/ PSI (315 bar)
RA 29 58/6.98 Proportional Pressure Relief Valve Models DBE and ZDBE, Series X Size 6 (R 3)... 46 PSI (35 bar)... 8 GPM (3 L/min) RA 29 58/6.98 Replaces: 5.94 Valve for limiting system pressure Operation
More informationProportional Electro-Hydraulic Flow Control (and Check) Valves
Ω Proportional Electro-ydraulic Flow Control (and Check) Valves Since the preselected flow rate continuously varies in proportion to the current input to the valve, the system flow rate can be remotecontrolled
More informationNSPB510AS RoHS Compliant
NICHIA CORPORATION SPECIFICATIONS FOR BLUE LED NSPB510AS RoHS Compliant SPECIFICATIONS (1) Absolute Maximum Ratings Item Symbol Absolute Maximum Rating Unit Forward Current I F 35 ma Pulse Forward Current
More information機関部自動化資料 DATA FOR AUTOMATIC AND REMOTE CONTROL OF MACHINERY SYSTEM
DATA-DJ(2004.6) 造船所 : SHIPBUILDER 船番 : HULL NO. 機関部自動化資料 DATA FOR AUTOMATIC AND REMOTE CONTROL OF MACHINERY SYSTEM ディーゼル船 Diesel Ship 日本海事協会 NIPPON KAIJI KYOKAI 記載要領 Summary of Description 1. 各欄の記載に適合する場合のみ
More informationOperation Manual [ECO-RICH R] Hybrid Hydraulic System DAIKIN INDUSTRIES, LTD. Oil Hydraulics Division. PIM [Operation Manual] 1/57
PIM-00051 1 [Operation Manual] 1/57 Hybrid Hydraulic System [ECO-RICH R] EHU15R EHU30R Operation Manual Oil Hydraulics Division PIM-00051 1 [Operation Manual] 2/57 Before using this
More information3 Port Solenoid Valve Direct Operated Poppet Type. Body type. T Body ported O Manifold. Valve option
3 Port Solenoid Valve Direct Operated Poppet Type VT317 Series Rubber Seal [Option] Note) CE-compliant: Electrical entry is applicable only for the DIN terminal. Compact yet provides a large flow capacity
More informationAR Series Variable Displacement Piston Pumps. AR Series Variable Displacement Piston Pumps. AR Series Variable Displacement Piston Pumps
Variable Displacement Piston Pumps AR Series Variable Displacement Piston Pumps Geometric Displacement Maximum cm 3 /rev Operating Pump Type Graphic Symbol Pressure Page 1 2 5 10 20 50 100 150 MPa Variable
More informationVariable Displacement Piston Pumps PISTON PUMP
Variable Displacement Piston Pumps 2 VRIBLE DISPL. - P**V SERIES Model P6V P2V Max. WkgPress MPa Max. Speed Displacement cm 3 /rev Page min - P3V P**V Series P4V 2 8 6 P7V PV P3V The P**V Series high performance
More information製品仕様書 Product Specification ノンシールドシェルストレートタイプキット 103XX-42X0-XXX 103XX-52X0-XXX 部品 106XX-4200-XXX 106XX-5200-XXX 3342-XX.
製品仕様書 Product Specification 3M 印 MR ノンシールドシェルストレートタイプキット 103XX-42X0-XXX 103XX-52X0-XXX 部品 106XX-4200-XXX 106XX-5200-XXX 3342-XX 10600-L0F0-X 3M Brand MR Non-Shielded Shell Straight Type Kit 103XX-42X0-XXX
More informationCompact Proportional Solenoid Valve
Compact Proportional Solenoid Valve Series Repeatability: % or less Hysteresis:1% or less Fluid Flow rate control range Note) Series Air, Inert gas to L/min to L/min Note) Varies depending on the model.
More informationFlow Control Valve. 1 Description. 2 Symbols. Series SRCA General. 1.2 Application examples way flow control way flow control
Flow Control Valve Series SRC.. plug-in coil for easy coil change flow rates are unaffected by changes in temperature or load compact design reduced p ZnNi coating (>70h DIN EN ISO 97 NSS) Description.
More informationSeries VKF300 VV061 V100 S070 VQD VKF VK VT VS
Rubber Seal 3 Port Solenoid Valve Series VKF300 Direct Operated Poppet Type Compact yet provides a large flow capacity Body width 18 mm Various manifold piping directions Output port: Manifold set-up allowing
More informationProportional Valves. Proportional solenoid valves for pressure and flow control
Proportional Valves Proportional solenoid valves for pressure and flow control EATON Vickers Screw-In Cartridge Valves V-VLOV-MC-E4 September, 7 - Electro- Proportional Valves Section Contents Typical
More information"A" Series Piston Pumps Variable Displacement-Single Pumps Electro-Hydraulic Proportional Pressure & Flow Control. Type
Variable Displacement-Single Pumps Electro-Hydraulic Proportional & Flow Type 6 / / 7 / 6 / 7 / 9 / Model Number Designation Safety valve Input Signal for Flow Input Signal for mplifier Proportional Solenoid
More informationEManually Operated Directional Valves
DIRECIONL CONROLS hese valves may be used to manually shift the spool position and change the direction of oil flow. hreaded Connections Sub-late Mounting Specifications DM--C - DM--D - DM--D - DM--B -
More informationディーゼル機関仕様書 ENGINE SPECIFICATIONS. 公式呼称 4JJ1 (Turbocharger) 社内呼称 AJ-4JJ1TYBW-01 Model No. EXPORT
No. IS-08-136-0 ( 1/9 ) 経歴 Rev. ディーゼル機関仕様書 ENGINE SPECIFICATIONS 0 機関型式 Engine Model 納入先 Customer 搭載機種 Application 公式呼称 4JJ1 (Turbocharger) Base Model 社内呼称 AJ-4JJ1TYBW-01 Model No. 一般輸出 EXPORT 一般動力 General
More information10 VQ F. Nil Latching type: Push-locking type (Tool required) B. Nil. Electrical entry
Series 0-VQ00 port solenoid valve How to Order Valves 0 VQ 0 F ir cylinder Clean series Series VQ Compact port valve Type of actuation Normally closed Note) Normally open Note) Normally open type is available
More informationDENISON HYDRAULICS open loop pump controls series P140 A-mod, P260 B-mod service information
DENISON HYDRAULICS open loop pump controls series P10 A-mod, P260 B-mod service information Publ. S1-AM02-A replaces S1-AM02 01-97 CONTENTS typical characteristics-------------------------------------------------------------------------------
More informationINTERLOCK CONNECTOR BOX
INSTRUCTION MANUAL INTERLOCK CONNECTOR BOX MODEL: TSC-MF-S MODEL: TSC-MF-M 4 th Edition August 26 2005 MADOKA SYSTEM CO., LTD. -1- CONTENTS 1. Outline 3 2. Component Units 4 2-1. Product Component Units
More informationSeries SYA3000/5000/7000
Port Air Operated Valve Series SYA000/000/7000 How to Order A, B port size Thread type Thread piping (Inch size) - Rc Symbol Port size Applicable series Symbol Port size Applicable series F G SYA000 N
More informationProportional pressure reducing valve, pilot operated
Proportional pressure reducing valve, pilot operated RE 29178/4.5 Replaces: 11.2 1/1 Types DRE(M) and DRE(M)E Size 32 1) Component series 4X Maximum operating pressure 315 bar Maximum flow 3 L/min H2448
More information" " Series Variable Displacement Piston Pumps
" " Series Variable Displacement Piston Pumps Compensator Type Constant Power (Torque) Control Type Load Sensing Type Pump Type Graphic Symbol Geometric Displacement cu. in./rev...5 5 5 5 5 cm /rev Maximum
More informationProportional pressure reducing valve, 3-way variant, pilot operated
roportional pressure reducing valve, 3-way variant, pilot operated RE 29286/1.1 Replaces: 2.8 1/14 ypes 3DRE(M) and 3DRE(M)E Sizes 1 and 16 Component series 7X Maximum pressure setting 315 bar (size 1)
More informationDirect Operated Type Directional and Flow Control Valves
Specifications igh Response Type Proportional Electro-ydraulic Directional and Flow Control Valves igh response, high precision and high reliability are achieved be a combination of a compact and powerful
More information1.8 w. 3 Port Solenoid Valve. VT307 Series. Direct Operated Poppet Type. Power consumption. A single valve with various valve functions
Port Solenoid Valve VT07 Series Direct Operated Poppet Type Power consumption 4 Standard wtype (Current product: 4.8 W) Energy-saving type.8 w (Current product: 2 W) Vacuum applications 0.2 kpa [Option]
More information0.45 ms. 9mm. High Speed 2 Port Valve. SX10 Series. 2 mounting types
Speed 2 Port Valve Series RoHS speed speed speed response response response 5 ms 9mm Width ±0.05 ms ±0.05 ms type VCH : : 5 ms * The response time is measured based on SMC test conditions. (Not guaranteed
More information4/2- and 4/3-Way Proportional Directional Control Valve Direct Operated, Model 4 WRA (Series 1X) PSI (315 bar) H/A 1768
/- and /-Way roptional Directional Control Valve Direct Operated, Model WR (Series X) Size 6 and... 6 SI ( bar).... GM (9 L/min) R 9 /6.98 R 9 /6.98 Replaces:.9 Characteristics: F the open loop control
More information29 160/ Proportional Pressure Relief Valve Model DBE, (Series 5X) Ordering Code DBE 5X Y G24 1/ PSI (350 bar)
Size 10, 25 Proportional Pressure Relief Valve Model DE, (Series 5X)... 5100 PSI (350 bar)... 106 GPM (400 L/min) R 29 160/06.98 R 29 160/06.98 Replaces: 05.94 Operation by means of proportional solenoid
More informationPROPORTIONAL ELECTRO-HYDRAULIC CONTOROLS
H PROPORTIONAL ELECTRO-HYDRAULIC CONTOROLS -Hybrid Components...Page Proportional Electro-Hydraulic Control Valves...Page 7 Proportional Electro-Hydraulic Controls High-accuracy, simple, convenient realizes
More informationFunctional Symbols and Application Notes
Functional Symbols and pplication Notes Model Types KHDG5V Shown Simplified symbol Model Types KHDG5V Shown K()FDG5V symbols identical, but omit pilot-stage LVDTs Simplified symbol T T Detailed symbol
More information03 SERIES. General Information Mounting Surface : ISO 4401-AC-05-4-A, CETOP-5, NFPA-DO2 Up to 25 MPa (3630 PSI), 70 L /min (18.5 U.S.
3 SERIES General Information Mounting Surface : ISO 44-C--4-, CETO-, N-DO Up to Ma (363 SI), 7 L /min (8. U.S.GM) ub. EC-43 MODULR VLVES The modular valves are functional elements with which a hydraulic
More information4/3 proportional directional control valve, without position control, with on-board electronics (OBE)
4/3 proportional directional control valve, without position control, with on-board electronics (OBE) Type 4WRBAE..E.. /..W.. Nominal size (NG) 6, 10 Unit series 2X Maximum working pressure P, A, B 315
More information10 SERIES MODULAR VALVES. Pub. EC-1405
SERIES General Information Mounting Surface : ISO ----, CETOP-, NP-D Up to 5 MPa (363 PSI), 8 L /m in ( U.S.GPM) Pub. EC-5 The modular valves are functional elements with which a hydraulic system can be
More informationDENISON HYDRAULICS Premier Series. open loop pump controls series P080. service information
DENISON HYDRAULICS Premier Series open loop pump controls series P080 service information Publ. S-AM0 Internet: http://www.denisonhydraulics.com E-mail: denison@ denisonhydraulics.com CONTENTS typical
More informationHigh-Speed Response Non-Isolated POL DC-DC Converter BSV-H Series
is a small (2.0x1.5x4.0mm), light (2.8g), 52.8W output power step-down DC-DC converter. With ultra-low output voltage from 0.8V, it can support the latest DSP, ASIC applications. High efficiency and ultra-high-speed
More informationNugget 40, V08 series
Nugget 0, V0 series Integrally ported 5/ and 5/3 Spool valves Solenoid actuated and pilot operated Ø, Ø mm or High flow from mm body width Wide range of voltages available Low profile fixed length manifolds
More informationE SERIES. Proportional Electro-Hydraulic Relief Valves. Specification. Model Number Designation. Attachment Mounting Bolts
ydraulic Relief s The electro hydraulic relief valve is designed for compactness and high efficiency. The valve provides fast proportional response to the input current. For linear pressure control a special
More information3-way Proportional pressure reducing valve, pilot operated
01/12 3-way roportional pressure reducing valve, pilot operated 6.6 ype 3DRE(M) and 3DRE(M)E Component series L6X NG 10 and 16 Max pressure 315 bar Max flow: 125L/min(size 10) 300L/min(size 16) Contents
More informationType C2 Seat Type Solenoid Pilot Valve
Type C Seat Type Solenoid Pilot Valve JIS graphic symbols for hydraulic system T eatures No hydraulic locking occurs even during long periods of pressurized operation Nomenclature 1 3 5 - - - - - 1 3 5
More informationProportional Pressure Reducing Valve, Size 16 Series DRPSB 5B...
Proportional Pressure Reducing Valve, Size 16 Series DRPSB B... l/min, bar External pilot drain to port 3 Surface protection: Cartridge is chromited, Cr VI free Very stable operation Coil can be changed
More informationNG06. General Size NG6 NG10 Design
Catalog HY14-255/US Series VY*K General Series VY*K pilot operated sequence valves feature proportional adjustment and an external drain. The external drain allows application as both a sequence valve
More informationCoolant Valve. Series VNC. Cylinder actuation by pilot air. Wide selection of port size and variations
Coolant Valve ir Operated/xternal Pilot Solenoid Cylinder actuation by pilot air Wide selection of port and variations hreaded type (6 to ) type (3 to ) Low water hammer or details, refer to page 07. Large
More informationCircuit of directional control valve and regulator. Simplifying circuit design. Space saving and piping. work eliminated. Automating pressure control
Port Electro-Pneumatic Proportional Valve Series VER000/000 Capable of actuating a cylinder and performing analog control of pressurization VER alone can be used to switch and actuate a cylinder and to
More informationIntermittent control timer
Contact our sales office regarding a delivery date or a price since this is a special model. P.G.Information (Specialized Product) SP095X-002E P: NU Intermittent control timer IZE110-X238 SMC CORPORATION
More information