W-300-AST Specifications

Size: px
Start display at page:

Download "W-300-AST Specifications"

Transcription

1 W-300-AST Specifications DISTANCE TO REMOVE INTERNAL SOLIDS 5 3/4" 27 1/4" 4.5" 10" TO WATER SUPPLY 0.5" MALE CONNECTOR 25 1/8" 11" CONTAINER, MODEL GC-2, 11.6 QUART CAPACITY 11" FRONT VIEW 9 3/8" 12" 5 1/4" FEATURES BACK VIEW No strainers to empty manually. The Automatic Solids Transfer feature automatically pumps incidental solids around the system. Fully automatic self-cleaning cycle. Removes collected grease/oils from tank without any operator assistance. 3" PIPE / END Constructed of corrosion resistant materials suitable for installation in virtually any location. Comes complete with Grease Collection Container and 24 hour Time Control. * Note: Not intended for use with solids larger than 1" (25 mm) in diameter. The FS-1 or ILS-1 solids strainers are recommended for use ahead of the AST system for sites with solids greater than 1". TECHNICAL INFORMATION Materials: 16 Gauge, 304 Stainless Steel, Bright Finish Electrical: 115 VAC 60 Hz 1500 Watts (13 amps) Maximum Inlet Flow Rate: 30 GPM Number of Skimming Wheels: 2 Skimming Rate: 52.5 Pounds Per Hour Grease Retention Capacity: 60 Pounds Eductor Pump Operation Water Requirements: 5 GPM 7/04 Thermaco, Inc. 646 Greensboro St. Asheboro, N. C., Phone (336)

2 W-300-AST Specifications INSTALLATION INFORMATION 2" DO... READ instruction manual included with system before doing anything. Install unit allowing for the minimum clearances shown. MINIMUM DISTANCE REQUIRED TO SERVICE HEATING ELEMENT 9 3/8" 1 7" 31-1/2" 4.5" INTERNAL FILTER ACCESS COVER SUMP CONTAINER 4" Provide a minimum 5 GPM, 50 PSI water supply for solids pump operation. Make sure the height above the Internal Strainer Access Cover is enough to remove the strainer. Make piping connections with rubber "No Hub" connectors. Keep outlet piping as straight as possible. Use only "sweep" connections. Install vent on outlet piping. Fill the tank with water before energizing the power to the motor and heater. PLAN VIEW DON'T... Install "P" trap on outlet connection of tank. (Note: the unit already has an internal gas trap). Reduce pipe size on outlet piping. Set Programmable Time Controllers for proper operating times. Note: Installations must comply with all applicable local, state, and national codes for your area. Job Specification: Grease and oil separator(s) shall be Thermaco BIG DIPPER automatic grease/oil recovery system with Automatic Solids Transfer as manufactured by Thermaco, Inc., Asheboro, North Carolina as noted on plans. Separator Specifications: Furnish and install Thermaco BIG DIPPER Model No. W-300-AST, bright finish type 304 stainless steel automatic self-cleaning grease and oil recovery separator(s) for floor mounted, partially recessed, or below floor installation, rated at 30 gallons per minute peak flow, 60 pounds of grease capacity and including as an integral part of the unit, 2 rotating gear hydrophobic wheel assemblies for automatic grease/oil removal, an integral flow control device, self-regulating enclosed electric immersion heater, a vessel vent, an integral gas trap, an integral programmable 24 hour multi-event time control, a field reversible grease/oil sump outlet pipe, quick release stainless steel lid clamps, a gasketted and fully removable 304 stainless steel lid with safety switch, a hinged lift out strainer access, one internal stainless steel filter basket for separation of coarse solids, an eductor transfer pump controlled by repeat cycle timer, and a separate grease and oils collection container. Eductor pump shall be supplied with a 0.5" male connector for attachment to facility-supplied water supply. Eductor pump shall be supplied with an integral atmospheric vacuum breaker. Electric assembly shall be tested to comply with pertinent sections of the Standards for Safety ANSI/UL 73 and/or ANSI/UL Skimmer electric motors shall be equipped with thermal overload protection with automatically resettable switch. 2 Thermaco, Inc. 646 Greensboro St. Asheboro, N. C., Phone (336) /04

3 W-500-AST Specifications DISTANCE TO REMOVE 10" INTERNAL SOLIDS 5 3/4" 34" 4 1/2" 12 1/2" CONTAINER, MODEL GC-5, 18 QUART CAPACITY 12 1/2" TO WATER SUPPLY 0.5" MALE CONNECTOR 25 1/8" FRONT VIEW BACK VIEW 9 3/8" 12" 5 1/4" FEATURES No strainers to empty manually. The Automatic Solids Transfer feature automatically pumps incidental solids around the system. Fully automatic self-cleaning cycle. Removes collected grease/oils from tank without any operator assistance. 4" PIPE / END Constructed of corrosion resistant materials suitable for installation in virtually any location. Comes complete with Grease Collection Container and 24 hour Time Control. * Note: Not intended for use with solids larger than 1" (25 mm) in diameter. The FS-1 or ILS-1 solids strainers are recommended for use ahead of the AST system for sites with solids greater than 1". TECHNICAL INFORMATION Materials: 16 Gauge, 304 Stainless Steel, Bright Finish Electrical: 115 VAC 60 Hz 1500 Watts (20 amps) Maximum Inlet Flow Rate: 50 GPM Number of Skimming Wheels: 2 Skimming Rate: 52.5 Pounds Per Hour Grease Retention Capacity: 110 Pounds Eductor Pump Operation Water Requirements: 5 GPM 7/04 Thermaco, Inc. 646 Greensboro St. Asheboro, N. C., Phone (336)

4 W-500-AST Specifications INSTALLATION INFORMATION DO... READ instruction manual included with system before doing anything. 4 5/8" Install unit allowing for the minimum clearances shown. 1 1/2" 14 1/2" 9 3/8" 7" 4 1/2" MINIMUM DISTANCE REQUIRED TO SERVICE HEATING ELEMENT INTERNAL FILTER ACCESS COVER 38 1/4" SUMP CONTAINER 4" Provide a minimum 5 GPM, 50 PSI water supply for solids pump operation. Make sure the height above the Internal Strainer Access Cover is enough to remove the strainer. Make piping connections with rubber "No Hub" connectors. Keep outlet piping as straight as possible. Use only "sweep" connections. Install vent on outlet piping. Fill the tank with water before energizing the power to the motor and heater. PLAN VIEW DON'T... Install "P" trap on outlet connection of tank. (Note: the unit already has an internal gas trap). Reduce pipe size on outlet piping. Set Programmable Time Controllers for proper operating times. Note: Installations must comply with all applicable local, state, and national codes for your area. Job Specification: Grease and oil separator(s) shall be Thermaco BIG DIPPER automatic grease/oil recovery system with Automatic Solids Transfer as manufactured by Thermaco, Inc., Asheboro, North Carolina as noted on plans. Separator Specifications: Furnish and install Thermaco BIG DIPPER Model No. W-500-AST, bright finish type 304 stainless steel automatic self-cleaning grease and oil recovery separator(s) for floor mounted, partially recessed, or below floor installation, rated at 50 gallons per minute peak flow, 110 pounds of grease capacity and including as an integral part of the unit, 2 rotating gear hydrophobic wheel assemblies for automatic grease/oil removal, an integral flow control device, self-regulating enclosed electric immersion heater, a vessel vent, an integral gas trap, an integral programmable 24 hour multi-event time control, a field reversible grease/oil sump outlet pipe, quick release stainless steel lid clamps, a gasketted and fully removable 304 stainless steel lid with safety switch, a hinged lift out strainer access, one internal stainless steel filter basket for separation of coarse solids, a eductor transfer pump controlled by repeat cycle timer, and a separate grease and oils collection container. Eductor pump shall be supplied with a 0.5" male connector for attachment to facility-supplied water supply. Eductor pump shall be supplied with an integral atmospheric vacuum breaker. Electric assembly shall be tested to comply with pertinent sections of the Standards for Safety ANSI/UL 73 and/or ANSI/UL Skimmer electric motors shall be equipped with thermal overload protection with automatically resettable switch. 4 Thermaco, Inc. 646 Greensboro St. Asheboro, N. C., Phone (336) /04

5 W-750-AST Specifications DISTANCE TO REMOVE INTERNAL SOLIDS 9 3/8" 12" 5 1/4" 10" 2" PLUG 15" 1-1/2" DRAIN PLUG CONTAINER, MODEL GC-3, 22 QT CAPACITY 15" 4" PIPE / FRONT VIEW 5 3/4" 48" 4 1/2" END FEATURES 6 3/4" 12 5/8" OPTIONAL SUMP LOCATION BACK VIEW TO WATER SUPPLY 0.5" MALE CONNECTOR 25 1/8" No strainers to empty manually. The Automatic Solids Transfer feature automatically pumps incidental solids around the system. Fully automatic self-cleaning cycle. Removes collected grease/oils from tank without any operator assistance. TECHNICAL INFORMATION Materials: 16 Gauge, 304 Stainless Steel, Bright Finish Electrical: (2) Motor (2) Heaters, VAC 60 Hz 3000 Watts (30 amps) total Maximum Inlet Flow Rate: 75 GPM Number of Skimming Wheels: 6 Skimming Rate: Pounds Per Hour Grease Retention Capacity: 218 Pounds Eductor Pump Operation Water Requirements: 5 GPM Constructed of corrosion resistant materials suitable for installation in virtually any location. Comes complete with Grease Collection Container and 24 hour Time Control. * Note: Not intended for use with solids larger than 1" (25 mm) in diameter. The FS-1 or ILS-1 solids strainers are recommended for use ahead of the AST system for sites with solids greater than 1". 7/04 Thermaco, Inc. 646 Greensboro St. Asheboro, N. C., Phone (336)

6 W-750-AST Specifications INSTALLATION INFORMATION DO /8" 9 3/8" 14 1/2" 1 1/2" 7" 4 1/2" MINIMUM DISTANCE REQUIRED TO SERVICE HEATING ELEMENT INTERNAL FILTER ACCESS COVER DON'T... Install "P" trap on outlet connection of tank. (Note: the unit already has an internal gas trap). CONTAINER PLAN VIEW 52 1/4" 4" SUMP Reduce pipe size on outlet piping. READ instruction manual included with system before doing anything. Install unit allowing for the minimum clearances shown. Provide a minimum 5 GPM, 50 PSI water supply for solids pump operation. Make sure the height above the Internal Strainer Access Cover is enough to remove the strainer. Make piping connections with rubber "No Hub" connectors. Keep outlet piping as straight as possible. Use only "sweep" connections. Install vent on outlet piping. Fill the tank with water before energizing the power to the motor and heater. Set Programmable Time Controllers for proper operating times. Note: Installations must comply with all applicable local, state, and national codes for your area. Job Specification: Grease and oil separator(s) shall be Thermaco BIG DIPPER automatic grease/oil recovery system with Automatic Solids Transfer as manufactured by Thermaco, Inc., Asheboro, North Carolina as noted on plans. Separator Specifications: Furnish and install Thermaco BIG DIPPER Model No. W-750-AST, bright finish type 304 stainless steel automatic self-cleaning grease and oil recovery separator(s) for floor mounted, partially recessed, or below floor installation, rated at 75 gallons per minute peak flow, 218 pounds of grease capacity and including as an integral part of the unit, 6 rotating gear hydrophobic wheel assemblies for automatic grease/oil removal, an integral flow control device, self-regulating enclosed electric immersion heater, a vessel vent, an integral gas trap, an integral programmable 24 hour multi-event time control, a field reversible grease/oil sump outlet pipe, quick release stainless steel lid clamps, a gasketted and fully removable 304 stainless steel lid with safety switch, a hinged lift out strainer access, one internal stainless steel filter basket for separation of coarse solids, an eductor transfer pump controlled by repeat cycle timer, and a separate grease and oils collection container. Eductor pump shall be supplied with a 0.5" male connector for attachment to facility-supplied water supply. Eductor pump shall be supplied with an integral atmospheric vacuum breaker. Electric assembly shall be tested to comply with pertinent sections of the Standards for Safety ANSI/UL 73 and/or ANSI/UL Skimmer electric motors shall be equipped with thermal overload protection with automatically resettable switch. 6 Thermaco, Inc. 646 Greensboro St. Asheboro, N. C., Phone (336) /04

7 W-1000-AST Specifications 10" DISTANCE TO REMOVE INTERNAL SOLIDS 9 3/8" 12" 5 1/4" 2" PLUG 16.5" 1-1/2" DRAIN PLUG CONTAINER, MODEL GC-3, 22 QT CAPACITY 16.5" 4" PIPE / FRONT VIEW END 6 13/1 60" 4 1/2" 6 3/4" 14 1/8" OPTIONAL SUMP LOCATION BACK VIEW TO WATER SUPPLY 0.5" MALE CONNECTOR 26 3/4" FEATURES No strainers to empty manually. The Automatic Solids Transfer feature automatically pumps incidental solids around the system. Fully automatic self-cleaning cycle. Removes collected grease/oils from tank without any operator assistance. TECHNICAL INFORMATION Materials: 16 Gauge, 304 Stainless Steel, Bright Finish Electrical: (2) Motors, VAC 60 Hz 120 Watts (2) Heaters, VAC 60 Hz 1 Ph 2880W. 3000W (30 amps) total Maximum Inlet Flow Rate: 100 GPM Number of Skimming Wheels: 6 Skimming Rate: Pounds Per Hour Grease Retention Capacity: 283 Pounds Eductor Pump Operation Water Requirements: 5 GPM Constructed of corrosion resistant materials suitable for installation in virtually any location. Comes complete with Grease Collection Container and 24 hour Time Control. * Note: Not intended for use with solids larger than 1" (25 mm) in diameter. The FS-1 or ILS-1 solids strainers are recommended for use ahead of the AST system for sites with solids greater than 1". 7/04 Thermaco, Inc. 646 Greensboro St. Asheboro, N. C., Phone (336)

8 W-1000-AST Specifications INSTALLATION INFORMATION DO... READ instruction manual included with system before doing anything. 4 5/8" 9 3/8" 14 1/2" 1 1/2" 7" 4 1/2" MINIMUM DISTANCE REQUIRED TO SERVICE HEATING ELEMENT INTERNAL FILTER ACCESS COVER DON'T... Install "P" trap on outlet connection of tank. (Note: the unit already has an internal gas trap). 65 5/1 4" SUMP CONTAINER PLAN VIEW Reduce pipe size on outlet piping. Install unit allowing for the minimum clearances shown. Provide a minimum 5 GPM, 50 PSI water supply for solids pump operation. Make sure the height above the Internal Strainer Access Cover is enough to remove the strainer. Make piping connections with rubber "No Hub" connectors. Keep outlet piping as straight as possible. Use only "sweep" connections. Install vent on outlet piping. Fill the tank with water before energizing the power to the motor and heater. Set Programmable Time Controllers for proper operating times. Note: Installations must comply with all applicable local, state, and national codes for your area. Job Specification: Grease and oil separator(s) shall be Thermaco BIG DIPPER automatic grease/oil recovery system with Automatic Solids Transfer as manufactured by Thermaco, Inc., Asheboro, North Carolina as noted on plans. Separator Specifications: Furnish and install Thermaco BIG DIPPER Model No. W-1000-AST, bright finish type 304 stainless steel automatic self-cleaning grease and oil recovery separator(s) for floor mounted, partially recessed, or below floor installation, rated at 100 gallons per minute peak flow, 272 pounds of grease capacity and including as an integral part of the unit, 6 rotating gear hydrophobic wheel assemblies for automatic grease/oil removal, an integral flow control device, self-regulating enclosed electric immersion heater, a vessel vent, an integral gas trap, an integral programmable 24 hour multi-event time control, a field reversible grease/oil sump outlet pipe, quick release stainless steel lid clamps, a gasketted and fully removable 304 stainless steel lid with safety switch, a hinged lift out strainer access, one internal stainless steel filter basket for separation of coarse solids, an eductor transfer pump controlled by repeat cycle timer, and a separate grease and oils collection container. Eductor pump shall be supplied with a 0.5" male connector for attachment to facility-supplied water supply. Eductor pump shall be supplied with an integral atmospheric vacuum breaker. Electric assembly shall be tested to comply with pertinent sections of the Standards for Safety ANSI/UL 73 and/or ANSI/UL Skimmer electric motors shall be equipped with thermal overload protection with automatically resettable switch. 8 Thermaco, Inc. 646 Greensboro St. Asheboro, N. C., Phone (336) /04

W-200-IS Specifications

W-200-IS Specifications MOTOR/TIMER ENCLOSURE Big Dipper Point Source Automatic W-200-IS Specifications 1 CLEARANCE REQUIRED FOR STRAINER BASKET & LID REMOVAL 14.75 2 PIPE / 17.5 END VIEW 19.5 GC-6 10.5 GREASE 10.5 6 QUART CAPACITY

More information

GREASE ENFORCER Operation & Maintenance Manual

GREASE ENFORCER Operation & Maintenance Manual Operation & Maintenance Manual Mohegan Sun Casino Uncasville, CT 8/17 88888 88888 88888 Copyright 2017 FOG Enforcer Toll Free: 1-844-235-0369 E-mail: ajetheridgeco@embarqmail.com Online: www.fogenforcer.com

More information

Installation & Operation Instructions For EZ Klear Systems Model EZK-25

Installation & Operation Instructions For EZ Klear Systems Model EZK-25 Installation & Operation Instructions For EZ Klear Systems Model EZK-25 * Conforms to ASME Standard ASME A112.14.3 * Please consult Thermaco, Inc. for specific models tested, certified and/or listed by

More information

www.cmadishmachines.com Table of Contents CMA-44 1. PARTS MANUAL... 4 1.1. Initial Parts Kit (P/N 13996.81)... 4 1.2. Initial Parts Kit (P/N 13996.80)... 5 1.3. Exploded View Drawings... 6 1.3.1. Cabinet

More information

www.cmadishmachines.com Table of Contents CMA-66 1. PARTS MANUAL... 4 1.1. Initial Parts Kit (P/N 13996.81)... 4 1.2. Initial Parts Kit (P/N 13996.80)... 5 1.3. Exploded View Drawings... 6 1.3.1. Cabinet

More information

Auxiliary Equipment. Option #397-12A Single Remote Pumping Unit (with Standard Pump & Motor) Duplex Remote Pumping Unit Option #397-12B

Auxiliary Equipment. Option #397-12A Single Remote Pumping Unit (with Standard Pump & Motor) Duplex Remote Pumping Unit Option #397-12B Auxiliary Equipment Option #397-12A Single Remote Pumping Unit (with Standard Pump & Motor) Duplex Remote Pumping Unit Option #397-12B 230 Fill Station AX-1 REMOTE PUMPING UNIT Option #397-12A Single Remote

More information

MODEL CMA-44 PARTS MANUAL Rev 2.13

MODEL CMA-44 PARTS MANUAL Rev 2.13 MODEL CMA-44 PARTS MANUAL Rev 2.13 CMA DISHMACHINES 12700 KNOTT AVENUE GARDEN GROVE, CALIFORNIA 92841 800-854-6417 FAX 714-895-2141 www.cmadishmachines.com Table of Contents CMA-44 1. PARTS MANUAL... 4

More information

Rev.2.06A www.cmadishmachines.com Table of Contents EST-44 1. PARTS MANUAL... 3 1.1. Initial Parts Kit... 3 1.2. Exploded View Drawings... 4 1.2.1. Cabinet Assembly... 4 1.2.2. Control Box Assembly (3

More information

Rev.2.05 www.cmadishmachines.com Table of Contents EST-44 1. PARTS MANUAL... 3 1.1. Initial Parts Kit... 3 1.2. Exploded View Drawings... 4 1.2.1. Cabinet Assembly... 4 1.2.2. Control Box Assembly... 5

More information

TYPE PC Propeller Condensate Pumps

TYPE PC Propeller Condensate Pumps SHIPPENSBURG PUMP CO. INC. P.O. BOX 279, SHIPPENSBURG, PA 17257 PH 717-532-7321 FAX 717-532-7704 WWW.SHIPCOPUMPS.COM BULLETIN 103 Revised 8/17 TYPE PC Propeller Condensate Pumps with Cast Iron Receivers

More information

CC3060 TYPE 12 COMPACT CABINET COOLER AIR-TO-WATER FLUSH-MOUNT MODEL

CC3060 TYPE 12 COMPACT CABINET COOLER AIR-TO-WATER FLUSH-MOUNT MODEL CC3060 TYPE 12 CC3060 13 lbs 9,300 0.3 1 x 6 30 x 8-3/4 x 4 Efficiency: 68.8 Watts / C T based on average internal cabinet temperature. 2. CC3060 Rated cooling: 2,725 Watts mounted to an uninsulated 72

More information

Packaged Design Day Tank Systems

Packaged Design Day Tank Systems Fuel Supply Systems Packaged Design Day Tank Systems for diesel/fuel oil application providing a reliable fuel source for diesel and turbine engine driven equipment and oil fired boilers model & accessory

More information

SPECIFICATIONS DOUGLAS MODEL LD-20 POT, PAN, AND UTENSIL WASHER

SPECIFICATIONS DOUGLAS MODEL LD-20 POT, PAN, AND UTENSIL WASHER B05D PAN WASHER B05D PAN WASHER xxxxxx Effective: March 1, 2005 SPECIFICATIONS DOUGLAS MODEL LD-20 POT, PAN, AND UTENSIL WASHER CABINET 50 wide x 36 deep x 73 high Clearance Height: 100-3/4 (103-1/2 with

More information

Centro-Matic Automatic Lubrication Systems FlowMaster Hydraulic Pump

Centro-Matic Automatic Lubrication Systems FlowMaster Hydraulic Pump FlowMaster Hydraulic Pump High-performance FlowMaster hydraulic pumps combine rotary-driven pump motors with reciprocating pump tubes and flexible control features that perform in desert heat and arctic

More information

Physical Property Analyzer PPA4100 Series. On-Line RVP Analyzer

Physical Property Analyzer PPA4100 Series. On-Line RVP Analyzer Physical Property Analyzer PPA4100 Series On-Line RVP Analyzer More accurate, on-line measurement of Reid Vapor Pressure will save millions of dollars in gasoline blending... the PPA4100 is more than an

More information

Setting the Global Standard for Quality, Durability and Reliability

Setting the Global Standard for Quality, Durability and Reliability www.greaseguardianusa.com All Stainless Steel Construction Fully Sealed Odorless System Leading Edge Technology ACTIVE AND FULLY AUTOMATIC GREASE REMOVAL SYSTEMS Setting the Global Standard for Quality,

More information

Series CC Condensate Units

Series CC Condensate Units Bulletin S-215F Series CC Condensate Units Simplex or Duplex 1,000 thru 15,000 sq. ft. EDR 250 thru 7,500 lb./hr. Cast Iron Receivers: for years of dependable service; warranted for 20 years from date

More information

PARTS MANUAL. American Dish Service ADS CONVEYOR DISHWASHER MODELS: ADC-66 L-R/R-L EFFECTIVE: MAY, 2011

PARTS MANUAL. American Dish Service ADS CONVEYOR DISHWASHER MODELS: ADC-66 L-R/R-L EFFECTIVE: MAY, 2011 EFFECTIVE: MAY, 2011 ADS CONVEYOR DISHWASHER MODELS: ADC-66 L-R/R-L PARTS MANUAL 900 Blake Street Edwardsville, Kansas 66111 (913)422-3700 05/08 213-0066 L-R / 214-0066 R-L ADC-66 Conveyor Dishwasher 2

More information

MODELS CMA-180/180TALL Including 480V MACHINES PARTS MANUAL Rev 2.08A

MODELS CMA-180/180TALL Including 480V MACHINES PARTS MANUAL Rev 2.08A MODELS CMA-180/180TALL Including 480V MACHINES PARTS MANUAL Rev 2.08A C M A D I S H M A C H I N E S 1 2 7 0 0 K N O T T A V E N U E GARDEN GROVE, CALIFORNIA 92841 800-8 5 4-6 4 1 7 FAX 714-895-2141 www.cmadishmachines.com

More information

The TR-Series are large volume,

The TR-Series are large volume, HYDROSTATIC TEST PUMPS Model TR-Series U p to 5.5GPM 5000PSI HYDRO INC. 3500 Arrowhead Drive Carson City Nevada 89706 web site: www.ricehydro.com e-mail: ricehydro@ricehydro.com Phone: (775) 885-1280 Fax:

More information

Installation, Operation & Service Manual. PPL Bag Filter Housings. Table of Contents Page No. Eaton Filtration, LLC

Installation, Operation & Service Manual. PPL Bag Filter Housings. Table of Contents Page No. Eaton Filtration, LLC Installation, Operation & Service Manual PPL Bag Filter Housings Eaton Filtration, LLC 900 Fairmount Avenue, Elizabeth, NJ 07207 Read all instructions before installation or operation of equipment. Failure

More information

LACT MEASUREMENT. Total Head = Or PSI = S.G. 2.31

LACT MEASUREMENT. Total Head = Or PSI = S.G. 2.31 LACT MEASUREMENT Prepared By: Ken A. Steward. P.E. Linco-Electromatic, Inc. 4580 West Wall Street Midland, Texas 79703 The Operation of L.A.C.T. Units The simplest approach to the understanding of the

More information

07 Oil Change & Diesel Transfer Pumps

07 Oil Change & Diesel Transfer Pumps 064 07 Oil Change & Diesel Transfer Pumps OIL CHAngE PuMPS Porta-Quick The Porta-Quick Portable Oil Changer makes quick, clean and easy oil changes onboard any boat, because it uses the vessel s own power

More information

FLOOD PROTECTION SHUT DOWN VALVE (3 and smaller)

FLOOD PROTECTION SHUT DOWN VALVE (3 and smaller) FLOOD PROTECTION SHUT DOWN VALVE ( and smaller) 01/10 2 6 To Floor Drain L X JB11 4 FS99 5 Installed upstream of Reduced Zone Backflow Preventer. Normally Open Valve - Closes when discharge from RPZ Relief

More information

Foam Supply Kits FOAM EDUCTORS FOAM EDUCTORS FOAM EDUCTORS FOAM SUPPLY KITS

Foam Supply Kits FOAM EDUCTORS FOAM EDUCTORS FOAM EDUCTORS FOAM SUPPLY KITS FOAM SUPPLY KITS Foam Supply Kits Elkhart offers two supply kits. Both kits include: One.75" quarter-turn, inlet valve assembly with elbow Quick-connect female coupling Quick-connect plug with chain Brushed

More information

Custom Shipyard and Military Facility Products

Custom Shipyard and Military Facility Products Custom Shipyard and Military Facility Products Safety Products Designed for Special Applications Respiratory Protection, Confined Space Ventilation and Portable Area Lighting Off the Shelf Or Custom Solutions

More information

Horizontal Circuit Switchers

Horizontal Circuit Switchers > Transformer Protection > CIRCUIT SWITCHERS C A T A L O G B U L L E T I N General Application Southern States Types CSH and CSH-B Horizontal Circuit Switchers provide an economical, versatile, space saving

More information

Smart controls Reliable operation User friendly design Plug and play operation

Smart controls Reliable operation User friendly design Plug and play operation Series H-ID RAINSETS Series H-ID Rainsets manage the distribution and water treatment functions of commercial rainwater system installations. The modular H-ID series is designed for indoor installations

More information

DESIGN, OPERATION & MAINTENANCE OF L.A.C.T. UNITS

DESIGN, OPERATION & MAINTENANCE OF L.A.C.T. UNITS DESIGN, OPERATION & MAINTENANCE OF L.A.C.T. UNITS INTRODUCTION The two most common methods of measuring the volume of petroleum liquids are tank gauging and liquid metering. The problems associated with

More information

Cascade. Aqua-Aire. Standard & Swivel Lift Spas, Optional Reservoir. Parts Breakdown & Assemblies Right, Left, and End Tub Access Door Systems

Cascade. Aqua-Aire. Standard & Swivel Lift Spas, Optional Reservoir. Parts Breakdown & Assemblies Right, Left, and End Tub Access Door Systems Cascade Aqua-Aire Standard & Swivel Lift Spas, Optional Reservoir Parts Breakdown & Assemblies Right, Left, and End Tub Access Door Systems X= Color, L- Left, W= Wide, T= Swivel Lift TUBS: 360010-X, 360010-XL,

More information

MODELS EAH / EC/E TALL/3-Door Parts Manual Revision 1.04A

MODELS EAH / EC/E TALL/3-Door Parts Manual Revision 1.04A MODELS EAH / EC/E TALL/3-Door Parts Manual Revision 1.04A CMA DISHMACHINES 12700 KNOTT STREET GARDEN GROVE, CALIFORNIA 92841 800-854- 6417 FAX 714-895-2141 www.cmadishmachines.com TABLE OF CONTENTS PARTS

More information

Basket Strainers. Applications. Pressures to 3705 PSIG. Temperatures to 800ºF FEATURES MATERIALS OF CONSTRUCTION END CONNECTIONS SIZES RATINGS

Basket Strainers. Applications. Pressures to 3705 PSIG. Temperatures to 800ºF FEATURES MATERIALS OF CONSTRUCTION END CONNECTIONS SIZES RATINGS Applications Process Industry Metals and Mining Power Industry Water & Waste Water Chemical Industry Pulp and Paper Oil and Gas Basket Strainers Pressures to 3705 PSIG FEATURES Temperatures to 800ºF Fabricated

More information

! IMPORTANT: READ BEFORE OPERATING

! IMPORTANT: READ BEFORE OPERATING $15.00 INSTALLATION, OPERATION AND MAINTENANCE MANUAL! IMPORTANT: READ BEFORE OPERATING Recovery and Filtration Systems DMV120 Gas Engine Recovery System GV19 GV23 GV26 TABLE OF CONTENTS INTRODUCTION...

More information

MODEL CMA-180UC PARTS MANUAL Rev 1.19A

MODEL CMA-180UC PARTS MANUAL Rev 1.19A MODEL CMA-180UC PARTS MANUAL Rev 1.19A C M A D I S H M A C H I N E S 1 2 7 0 0 K N O T T A V E N U E GARDEN GROVE, CALIFORNIA 92841 800-8 5 4-6 4 1 7 FAX 714-895-2141 wwwcmadishmachines.com TABLE OF CONTENTS

More information

DME Valve Gate Controls

DME Valve Gate Controls DME ENERGY EFFICIENT, RELIABLE AND COMPACT HYDRAULIC AND PNEUMATIC CONTROLS 30 DME Valve Gate Controller Products and Solutions DME Valve Gate Controller Products and Solutions Solid-state timers and relays

More information

Aqua Ultraviolet Sunami Series Pumps 1/3HP, 3/4HP, 3HP, 4HP, 5HP

Aqua Ultraviolet Sunami Series Pumps 1/3HP, 3/4HP, 3HP, 4HP, 5HP TM 42371 Avenida Alvarado Temecula, CA 92590 TOLL FREE (800) 454-2725 TEL (951) 296-3480 FAX (951) 296-3490 www.aquauv.com Aqua Ultraviolet Sunami Series Pumps 1/3HP, 3/4HP, 3HP, 4HP, 5HP Sunami Warranty

More information

07 Oil Change & Diesel Transfer Pumps

07 Oil Change & Diesel Transfer Pumps 64 07 Oil Change & Diesel Transfer Pumps OIL CHANGE PUMPS Porta-Quick The Porta-Quick Portable Oil Changer makes quick, clean and easy oil changes onboard any boat because it uses the vessel s own power

More information

Hot Water Generator Systems Water to Water Steam to Water. Horizontal or Vertical Jacketed & Insulated

Hot Water Generator Systems Water to Water Steam to Water. Horizontal or Vertical Jacketed & Insulated Horizontal or Vertical Jacketed & Insulated Lochinvar s Hot Water Generator Systems are ideal when boiler capacity is sufficiently sized to cover potable hot water demand and provide source water for hydronic

More information

'G SER1ES. lnstallation & Operation Instructions For G Series Systems. Convenient Compliance for the Removal of Kitehen Grease

'G SER1ES. lnstallation & Operation Instructions For G Series Systems. Convenient Compliance for the Removal of Kitehen Grease --t 'G SER1ES Convenient Compliance for the Removal of Kitehen Grease lnstallation & Operation Instructions For G Series Systems Models G-25-E and G-35-E G-25-E Servicing A Pre-Rinse Sink G-25-E Servicing

More information

Owners Manual: - Pumps

Owners Manual: - Pumps Owners Manual: - Pumps GENERAL SAFETY RULES 1. The products mentioned in this manual are specially designed for the pre-filtering and re-circulation of water in swimming pools and spas. 2. They are designed

More information

MODELS EAH / EC/E TALL/3-Door Parts Manual Revision 1.03B

MODELS EAH / EC/E TALL/3-Door Parts Manual Revision 1.03B MODELS EAH / EC/E TALL/3-Door Parts Manual Revision 1.03B C M A D I S H M A C H I N E S 1 2 7 0 0 K N O T T S T R E E T GARDEN GROVE, CALIFORNIA 92841 800-8 5 4-6 4 1 7 FAX 714-895-2141 www.cmadishmachines.com

More information

HALLMARK INDUSTRIES INC

HALLMARK INDUSTRIES INC Performance Part No. HP. CONVERTIBLE JET PUMP USER S MANUAL GPH of Water @ Total Discharge Pressure of 40 psi Max. Pressure Max suction (shallow well) Max Suction (deep well) Max GPM (@0 head) Max Discharge

More information

CEX-32 LARGE CAPACITY, HEAVY DUTY ENGINE COOLANT EXTRACTION AND RE-FILLING SYSTEM

CEX-32 LARGE CAPACITY, HEAVY DUTY ENGINE COOLANT EXTRACTION AND RE-FILLING SYSTEM CEX-32 LARGE CAPACITY, HEAVY DUTY ENGINE COOLANT EXTRACTION AND RE-FILLING SYSTEM ESOC has developed a unique system that allows for the extraction, storing and re-filling of large capacity engine coolant

More information

ISTEC MAGNETIC METERS

ISTEC MAGNETIC METERS ISTEC MAGNETIC METERS MEASURE ANY CONDUCTIVE LIQUIDS OR SLURRIES (EVEN ABRASIVE OR CORROSIVE) WITH THE NEW MICROPROCESSOR-BASED MAGNETIC METER -- A QUALITY PRODUCT - SIMPLE - RELIABLE - AT AN AFFORDABLE

More information

MODEL CMA-180UC PARTS MANUAL Rev 1.19

MODEL CMA-180UC PARTS MANUAL Rev 1.19 MODEL CMA-180UC PARTS MANUAL Rev 1.19 CMA DISHMACHINES 12700 KNOTT AVENUE GARDEN GROVE, CALIFORNIA 92841 800-854- 6417 FAX 714-895-2141 wwwcmadishmachines.com TABLE OF CONTENTS MODEL CMA-180UC 1. PARTS

More information

MAP Automatic Strainers In-Line Series

MAP Automatic Strainers In-Line Series MAP Automatic Strainers In-Line Series flow rate filtration degrees inlet / outlet diameters min. operating pressure up to 4.500 m 3 /h (19.800 gpm) 5.000 200 micron up to DN800 (32 ) 1 bar (15 psi) Heavy

More information

PARTS MANUAL. American Dish Service MODELS: ADC-44 L-R/R-L ADS CONVEYOR DISHWASHER EFFECTIVE: MAY, 2008

PARTS MANUAL. American Dish Service MODELS: ADC-44 L-R/R-L ADS CONVEYOR DISHWASHER EFFECTIVE: MAY, 2008 EFFECTIVE: MAY, 2008 ADS CONVEYOR DISHWASHER MODELS: ADC-44 L-R/R-L PARTS MANUAL 900 Blake Street Edwardsville, Kansas 66111 (913)422-3700 05/08 211-0044L-R / 212-0044R-L ADC-44 Conveyor Dishwasher 2 211-0044L-R

More information

Updated: October 2012

Updated: October 2012 T: (630) 794-5100 EMERGENCY POWER FUEL SYSTEMS Earthsafe Systems, Inc. 7320 S. Madison Willowbrook, IL 60527 F: (630) 794-5106 info@earthsafe.com www.earthsafe.com Updated: October 2012 The information

More information

Why measure viscosity in-line?

Why measure viscosity in-line? BROOKFIELD _ WHY MEASURE VISCOSITY IN-LINE Why measure viscosity in-line? Why Measure Viscosity In-Line? Practical application of viscosity measurement data often leads to the need for in-process control

More information

Tank Filling Systems for Petroleum Products

Tank Filling Systems for Petroleum Products for Petroleum Products Insight Onsite for Petroleum Products Page 2 What is it used for? Generally used with aboveground storage tanks, although some underground uses as well. What is it? An easy means

More information

W91/W94 Series TEMPERATURE REGULATORS. Self-Operated Temperature Regulators. Design & Operation W91 Non-Indicating W94 Dial Thermometer

W91/W94 Series TEMPERATURE REGULATORS. Self-Operated Temperature Regulators. Design & Operation W91 Non-Indicating W94 Dial Thermometer Design & Operation W91 Non-Indicating W94 Dial Thermometer Watson McDaniel reserves the right to change the designs and/or materials of its products without notice. 2010 Watson McDaniel Company CAPILLARY

More information

CT SEPARATOR SYSTEM OPERATION & MAINTENANCE MANUAL

CT SEPARATOR SYSTEM OPERATION & MAINTENANCE MANUAL CT SEPARATOR SYSTEM OPERATION & MAINTENANCE MANUAL PLEASE RECORD THE FOLLOWING DATA (Information is located on the product label or packing slip) Model Number: Date Code: Installation Date: Installation

More information

STYLE 9300 FLOW/PRESSURE METER INSTALLATION & OPERATING INSTRUCTIONS

STYLE 9300 FLOW/PRESSURE METER INSTALLATION & OPERATING INSTRUCTIONS STYLE 9300 FLOW/PRESSURE METER INSTALLATION & OPERATING INSTRUCTIONS INTRODUCTION The Style 9300 Flow/Pressure Meter from Akron is designed to offer reliable and accurate service with an easy to install,

More information

500 Series DI. 500 Series DI. Materials and Specifications. Magnetic Drive Positive Displacement Disc Meters Sizes 1-1/2 and 2. Features.

500 Series DI. 500 Series DI. Materials and Specifications. Magnetic Drive Positive Displacement Disc Meters Sizes 1-1/2 and 2. Features. Features APPLICATIONS: Measurement of cold water for residential, commercial and industrial applications where water volumes are low, and low flow sensitivity is important. CONFORMANCE TO STANDARDS: Hersey

More information

PACIFIC Recumbent Height-Adjustable Bath System Parts Breakdown and Assembly Manual

PACIFIC Recumbent Height-Adjustable Bath System Parts Breakdown and Assembly Manual PACIFIC Recumbent Height-Adjustable Bath System 9700 Parts Breakdown and Assembly Manual Panel 390010-1 Tubs 390011-1 or 390022-1 390748 Revision H 4/1/2014 PENNER PATIENT CARE, INC Box 523 / 101 Grant

More information

M O D E L S EST- FL PARTS MANUAL Rev 1.00A

M O D E L S EST- FL PARTS MANUAL Rev 1.00A M O D E L S EST- FL PARTS MANUAL Rev 1.00A C M A D I S H M A C H I N E S 1 2 7 0 0 K N O T T S T R E E T GARDEN GROVE, CALIFORNIA 92841 800-8 5 4-6 4 1 7 FAX 714-895-2141 www.cmadishmachines.com TABLE

More information

ADJ200 Smart Skimmer and 2500ES Electronic Controller Single Skimmer Operations Manual

ADJ200 Smart Skimmer and 2500ES Electronic Controller Single Skimmer Operations Manual ADJ200 Smart Skimmer and 2500ES Electronic Controller Single Skimmer Operations Manual Caution: Read rules for safe operation and instructions carefully. 3 YEAR WARRANTY This product is warranted to the

More information

Submersible Effluent Pump

Submersible Effluent Pump ME45 Submersible Effluent Pump INSTALLATION, OPERATION, & PARTS MANUAL SAFETY INFORMATION Carefully read and follow all safety instructions in this manual or on pump. This is the safety alert symbol. When

More information

Includes electric operated valve Pressure gauge with siphon, vacuum breaker and air vent BOILER UNITS

Includes electric operated valve Pressure gauge with siphon, vacuum breaker and air vent BOILER UNITS STEAM / HOT WATER MODELS HWG FEATURES A. O. Smith hot water generators are available for operation with steam or boiler water as the energy source. They are completely assembled with components sized,

More information

This catalog contains the following geothermal accessory products and specification guides:

This catalog contains the following geothermal accessory products and specification guides: f o r r e s i d e n t i a l s y s t e m s Geothermal systems offer an effective way to cut utility costs while ensuring comfort. Heat Controller s line includes two stage and single stage geothermal heat

More information

MultiPort Lubricator. Electric motor-driven, Grease and Oil. General. Technical Data. Motor R3 09/09

MultiPort Lubricator. Electric motor-driven, Grease and Oil. General. Technical Data. Motor R3 09/09 MultiPort Lubricator Electric motor-driven, Grease and Oil General The MultiPort Lubricator is a rugged, motor-driven, electric lubricator, equipped with fixed output pumping elements to discharge grease

More information

Horizontal Circuit Switchers

Horizontal Circuit Switchers > Transformer Protection > CIRCUIT SWITCHERS C A T A L O G B U L L E T I N General Application Southern States Types CSH and CSH-B Horizontal Circuit Switchers provide an economical, versatile, space saving

More information

PRYCO, INC. P. O. BOX 108 Mechanicsburg, IL OPERATIONS AND MAINTENANCE MANUAL For PUMP SETS

PRYCO, INC. P. O. BOX 108 Mechanicsburg, IL OPERATIONS AND MAINTENANCE MANUAL For PUMP SETS PRYCO, INC. P. O. BOX 108 Mechanicsburg, IL 62545 Telephone: 217 / 364-4467 Fax: 217 / 364-4494 OPERATIONS AND MAINTENANCE MANUAL For PUMP SETS WHAT TO DO FIRST Upon receiving your new pump set system

More information

MARFAID Solenoid Valves

MARFAID Solenoid Valves Series 125 2-Way Normally Closed Pilot Operated Diaphragm Type Bronze Construction Wide Variety of Voltages Maximum Temperature 190 F Pressure Range 5-150 psi Horizontal or Vertical Installation 1-15 4"

More information

SERIES WC & WCS. Watchman Series & WCS Condensate Units. Replacement Parts for. Hoffman PARTS LIST DN0436. Hoffman Pump

SERIES WC & WCS. Watchman Series & WCS Condensate Units. Replacement Parts for. Hoffman PARTS LIST DN0436. Hoffman Pump Hoffman PARTS LIST DN06 REVISION B Watchman Series WC Cast Iron Receiver Single or Duplex Replacement Parts for Watchman Series WCS Steel Receiver Single or Duplex Watchman Series WC & WCS Condensate Units

More information

Priming Systems Installation Instructions

Priming Systems Installation Instructions Priming Systems Installation Instructions System Components: Single Priming Pump: Single VAP Valve Systems: Control Panel Activated... 2 Auto Prime (Pressure Switch) Activated... 3 Multiple VAP Valve Systems...

More information

MODEL 10LH SPECIFICATION

MODEL 10LH SPECIFICATION MODEL 10LH SPECIFICATION 1.0 General Specifications There will be furnished one (1) only Grind Hog TM Model 10LH Comminutor as manufactured by G.E.T. Industries, Inc. Rotation shall be in a clockwise (standard)

More information

Sample Specifications 2110_KA.DOC KOBELCO KNW SERIES 1 OF 10 AIR-COOLED, OIL FREE AIR COMPRESSOR Frame 0, 1, HP

Sample Specifications 2110_KA.DOC KOBELCO KNW SERIES 1 OF 10 AIR-COOLED, OIL FREE AIR COMPRESSOR Frame 0, 1, HP KOBELCO KNW SERIES 1 OF 10 1. SPECIFICATIONS SCOPE 1.1 This specification covers the requirement for supply of a packaged oil-free rotary screw air compressor, Kobelco KNW Series model. 1.2 Any and all

More information

Section 9: Centralized Lubrication Systems

Section 9: Centralized Lubrication Systems ALEMITE LUBRICATION EQUIPMENT AND FLUID HANDLING PRODUCTS Oil Mist Systems Introduction Alemite Oil Mist Systems are used to service all types of machine elements that require continuous lubrication, such

More information

CATALOG OF REPLACEMENT PARTS

CATALOG OF REPLACEMENT PARTS CATALOG OF REPLACEMENT PARTS C24GA6 & C24GA10 Gas Convection Steamers C24GA6 ML-136056 C24GA10 ML-136057 C24GA6 ML-136021 C24GA10 ML-136022 VULCAN-HART DIVISION OF ITW FOOD EQUIPMENT GROUP, LLC 3600 NORTH

More information

Compact LTC Oil Filtration System Manual

Compact LTC Oil Filtration System Manual INSTRUCTION MANUAL Compact LTC Oil Filtration System Manual COMPACT LTC OFS-MANUAL 1.4 READ AND UNDERSTAND THIS MANUAL PRIOR TO OPERATING OR SERVICING THIS PRODUCT. TABLE OF CONTENTS General System Description

More information

DC3Training.com N28AA DC-3 Pilot s Handbook

DC3Training.com N28AA DC-3 Pilot s Handbook SECTION 9 FUEL SYSTEM Index General page 2 Operation page 5 Limitations page 6 Troubleshooting page 6 5/15/2012 crew@dc3training.com 1 GENERAL A. Fuel Tanks The dual fuel system has a total capacity of

More information

TOP AND CABINET PARTS For Models: LSQ7030LQ0, LSQ7030LT0 (Designer White) (Biscuit)

TOP AND CABINET PARTS For Models: LSQ7030LQ0, LSQ7030LT0 (Designer White) (Biscuit) TOP AND CABINET PARTS AUTOMATIC WASHER 7 02 Litho in U.S.A. (drd) 1 Part No. TOP AND CABINET PARTS 1 Literature Parts LIT3956025 Installation Instructions LIT3955869 Use & Care Guide LIT3955562 Energy

More information

08 general Purpose Pumps

08 general Purpose Pumps 070 08 general Purpose Pumps InTRODuCTIOn Ballast Pumps Today s Wakeboard and Ski tow boats need to be able to take on water ballast to modify their wake formation. A development of our tried and tested

More information

THE MAGNUM SUCTION SYSTEM

THE MAGNUM SUCTION SYSTEM LARRY HESS AND ASSOCIATES, INC. BLAST-IT-ALL P.O. BOX 1615 SALISBURY, NC 28145 WWW.BLAST-IT-ALL.COM THE MAGNUM SUCTION SYSTEM MANUAL NUMBER: 564 TABLE OF CONTENTS PAGE FIGURE 1 - SET-UP INSTRUCTIONS 2

More information

Suction Spares and Accessories 2009

Suction Spares and Accessories 2009 MUL91600101 Black Rubber Feet for Machined Base Plates, (Pack of 5) MUL8150038 Black Rubber Feet for Machined Base Plates, (Pack of 4) b MUL94004000 Illuminated Green Rocker Switch (L30mm x W25mm x D30mm)

More information

abc CPD7948/075 Rotors, rotor shafts and rotor casings are coated with an anti-corrosive and anti wear coating to prolong element life and efficiency.

abc CPD7948/075 Rotors, rotor shafts and rotor casings are coated with an anti-corrosive and anti wear coating to prolong element life and efficiency. CPD7948/075 Specification Oil-Free, Air Cooled, Rotary Screw Compressors - Dryclon Range Models D75, D90, D110, D132, D150 (50Hz) D55, D75, D90, D110, D150 (60Hz) COMPRESSOR PACKAGE An enclosed two stage

More information

348002K/348012K Manifold Block Style Service Manual 12/2000

348002K/348012K Manifold Block Style Service Manual 12/2000 348002K/348012K Manifold Block Style Service Manual 12/2000 Service Manual 348002K/348012K Manifold Block Style Recovery/Recycling/Recharging Unit For R-12 or R-134a Only TABLE OF CONTENTS: Theory of Operation

More information

SHURFLO HIGH FLOW SYSTEM II 10.0 GPM MARINE FRESH WATER SYSTEM PRODUCT TECHNICAL DATA SHEET

SHURFLO HIGH FLOW SYSTEM II 10.0 GPM MARINE FRESH WATER SYSTEM PRODUCT TECHNICAL DATA SHEET SHURFLO HIGH FLOW SYSTEM II 10.0 GPM MARINE FRESH WATER SYSTEM PRODUCT TECHNICAL DATA SHEET OEM: AFTERMARKET: 4558-153-E75 4558-153-E75 APPLICATION: Multi-fixture Marine fresh water system installation.

More information

Installation & Operating Manual

Installation & Operating Manual Installation & Operating Manual VN Series Non-Clog Pumps Congratulations On Your Choice In Purchasing This Webtrol Pump 10/15 Edition Its Quality is unsurpassed in material and workmanship and has been

More information

THE WARRANTY SET FORTH HEREIN IS GIVEN EXPRESSLY AND IS THE ONLY WARRANTY GIVEN BY THE COMPANY WITH RESPECT TO THE PRODUCT.

THE WARRANTY SET FORTH HEREIN IS GIVEN EXPRESSLY AND IS THE ONLY WARRANTY GIVEN BY THE COMPANY WITH RESPECT TO THE PRODUCT. Series 909 Reduced Pressure Zone Backflow Preventers Sizes: 3 /4" 2" (20 50mm) Installation Service Repair Kits Maintenance No. 1 1 2" shown Patent Number 4,241,752 IMPORTANT: Inquire with governing authorities

More information

Industrial Generator Set Accessories

Industrial Generator Set Accessories Industrial Generator Set Accessories Aluminum and Steel and Subbase Fuel Tank Package All Generator Set,, and Fuel Tank Options are UL 2200 Certified. Available Approvals and Listings - UL 2200 Listing

More information

earth safe Fuel Systems for Critical Power

earth safe Fuel Systems for Critical Power Point Level Sensors S100 Tank Refill Level Sensor 4/5 Point S101 Tank High level Sensor 3 Point S102 Tank Low Level Sensor 1 Point S103 Tank High Level Vent Sensor Level Transmitters S120 Tank Level Transmitter

More information

Automatic Self-Cleaning Strainer/Filter Systems

Automatic Self-Cleaning Strainer/Filter Systems Automatic Self-Cleaning Strainer/Filter Systems The Eliminator 1432 Walnut Street Erie, PA 16502 USA 814.453.5014 - PH 814.452.6573 - FAX www.fluideng.com The Hyper-Jet Engineered Products for Demanding

More information

Model and Series 115 VAC INDUSTRIAL DIAPHRAGM PUMPS. PumpAgents.com - buy pumps and parts online INDUSTRIAL DIAPHRAGM PUMPS

Model and Series 115 VAC INDUSTRIAL DIAPHRAGM PUMPS. PumpAgents.com - buy pumps and parts online INDUSTRIAL DIAPHRAGM PUMPS Model 31801 and 31800 Series 115 VAC INDUSTRIAL DIAPHRAGM PUMPS INDUSTRIAL DIAPHRAGM PUMPS FEATURES Run Dry Ability Self-Priming Thermal Overload Protected Motor Easy Installation Low Amp Draw Compact

More information

ADJ1015L High Performance Smart Skimmer with Extended Travel and 2500ES Electronic Controller Single Skimmer Operations Manual

ADJ1015L High Performance Smart Skimmer with Extended Travel and 2500ES Electronic Controller Single Skimmer Operations Manual ADJ1015L High Performance Smart Skimmer with Extended Travel and 2500ES Electronic Controller Single Skimmer Operations Manual Caution: Read rules for safe operation and instructions carefully. 3 YEAR

More information

Model &

Model & PumpAgents.com - Click here for Pricing/Ordering Model 31765-0092 & 31765-0094 Dual Sensor Max VSD WATER PRESSURE SYSTEM AUTOMATIC TWO STAGE WATER SYSTEM WITH PUMPGARD STRAINERS IDEAL FOR PLEASURE AND

More information

MODEL CMA-181GW PARTS MANUAL Rev 1.00B

MODEL CMA-181GW PARTS MANUAL Rev 1.00B MODEL CMA-181GW PARTS MANUAL Rev 1.00B C M A D I S H M A C H I N E S 1 2 7 0 0 K N O T T A V E N U E GARDEN GROVE, CALIFORNIA 92841 800-8 5 4-6 4 1 7 FAX 714-895-2141 wwwcmadishmachines.com TABLE OF CONTENTS

More information

Foam Supply Kits FOAM EDUCTORS FOAM EDUCTORS FOAM EDUCTORS FOAM SUPPLY KITS

Foam Supply Kits FOAM EDUCTORS FOAM EDUCTORS FOAM EDUCTORS FOAM SUPPLY KITS FOAM SUPPLY KITS Foam Supply Kits Elkhart offers two supply kits. Both kits include: One.75 quarter-turn, inlet valve assembly with elbow Quick-connect female coupling Quick-connect plug with chain Brushed

More information

TStrainers. Applications. Pressures to 3705 PSIG Temperatures to 800ºF FEATURES MATERIALS END CONNECTIONS SIZES RATINGS

TStrainers. Applications. Pressures to 3705 PSIG Temperatures to 800ºF FEATURES MATERIALS END CONNECTIONS SIZES RATINGS Applications Steam, Liquid, Gas and Oil Service Process Equipment Water and Waste Power Industry Pulp and Paper Chemical Industry Metals and Mining TStrainers Pressures to 3705 PSIG Temperatures to 800ºF

More information

INDUSTRIAL GRADE WATER SOFTENERS LWTSF INDUSTRIAL SERIES

INDUSTRIAL GRADE WATER SOFTENERS LWTSF INDUSTRIAL SERIES INDUSTRIAL GRADE WATER SOFTENERS LWTSF INDUSTRIAL SERIES 150,000 TO 1,100,000 GRAINS CAPACITY (Single, Twin, Triple or Quadruple Demand Systems Available) 1 P age Industrial Performance and Proven Reliability

More information

CATALOG OF REPLACEMENT PARTS C24GA6 & C24GA10 GAS CONVECTION STEAMERS PRIOR MLS COVERED IN THIS MANUAL

CATALOG OF REPLACEMENT PARTS C24GA6 & C24GA10 GAS CONVECTION STEAMERS PRIOR MLS COVERED IN THIS MANUAL CATALOG OF REPLACEMENT PARTS C24GA6 & C24GA10 GAS CONVECTION STEAMERS C24GA6 C24GA10 ML-136056 ML-136057 PRIOR MLS COVERED IN THIS MANUAL C24GA6 C24GA10 ML-136021 ML-136022 For additional information on

More information

Self Cleaning Hood System Installation, Operation, and Maintenance Manual

Self Cleaning Hood System Installation, Operation, and Maintenance Manual Self Cleaning Hood System Installation, Operation, and Maintenance Manual RECEIVING AND INSPECTION Upon receiving unit, check for any interior and exterior damage, and if found, report it immediately to

More information

ROGERS MACHINERY COMPANY, INC

ROGERS MACHINERY COMPANY, INC KOBELCO KNW SERIES Sample Specifications AIR-COOLED, OIL-FREE AIR COMPRESSOR Frame 0, 1, 2 50 500 HP ROGERS 2110_KA.doc Effective: 03-24-17 Supersedes: 04-06-15 Page 1 of 9 1. SPECIFICATIONS SCOPE 1.1

More information

BATTERY WASH CABINETS, WASH STATIONS, RECIRCULATION/NEUTRALIZATION SYSTEM

BATTERY WASH CABINETS, WASH STATIONS, RECIRCULATION/NEUTRALIZATION SYSTEM BATTERY WASH CABINETS, WASH STATIONS, RECIRCULATION/NEUTRALIZATION SYSTEM Complete Product Line A cost-effective solution for extending the life of batteries and reducing lift truck electrical problems

More information

TOP AND CABINET PARTS For Models: LSQ8243HQO, LSQ8243HZ0 (White) (Almond)

TOP AND CABINET PARTS For Models: LSQ8243HQO, LSQ8243HZ0 (White) (Almond) TOP AND CABINET PARTS AUTOMATIC WASHER 12-98 Litho in U.S.A. (cre) 1 Part No. TOP AND CABINET PARTS 1 357213 Nut, Push-In (2) 2 Top 3949476 White 3949477 Almond 3 62750 Spacer, Cabinet To Top (4) 5 Cabinet

More information

APPENDIX A GENERAL PURPOSE STEAM TURBINE DATA SHEETS

APPENDIX A GENERAL PURPOSE STEAM TURBINE DATA SHEETS APPENDIX A GENERAL PURPOSE STEAM TURBINE DATA SHEETS 29 JOB NO. GENERAL-PURPOSE STEAM TURBINE PURCHASE ORDER NO. DATA SHEET SPECIFICATION NO. SI UNITS REVISION NO. DATE PAGE 1 OF 3 BY ITEM NO. 1 APPLICABLE

More information

MAINTENANCE SCHEDULE

MAINTENANCE SCHEDULE MAINTENANCE SCHEDULE System Check Item Daily 50 250 500 1000 1500 2000 Grease PTO anti-rotating shields Grease and lubricate ales and PTO bearings Grease fan motor (1 pump) (DO NOT OVER GREASE) Grease/Lube

More information

SELF PRIMING CHEMICAL SERVICE PUMPS

SELF PRIMING CHEMICAL SERVICE PUMPS SELF PRIMING CHEMICAL SERVICE PUMPS INSTALLATION AND OPERATING INSTRUCTIONS This Manual covers: SELF PRIMING MODEL RANGE J50ECX TO J250ECX STAINLESS STEEL*, and NON METALLIC SEAL PUMP MODEL: SERIAL NO:

More information

Marina Power and Lighting, Inc. General Specifications for the Newport Harbor Mate

Marina Power and Lighting, Inc. General Specifications for the Newport Harbor Mate Marina Power and Lighting, Inc. General Specifications for the Newport Harbor Mate All Power Pedestals Must Meet the Following: Part I. General: 1.1 General Requirements- A.) Shall be tested and certified

More information