CT SEPARATOR SYSTEM OPERATION & MAINTENANCE MANUAL
|
|
- Augustus Baldwin
- 5 years ago
- Views:
Transcription
1 CT SEPARATOR SYSTEM OPERATION & MAINTENANCE MANUAL PLEASE RECORD THE FOLLOWING DATA (Information is located on the product label or packing slip) Model Number: Date Code: Installation Date: Installation Location / Application: The above information will help when ordering replacement parts for your Wingert Purge System. J.L. WINGERT MANUFACTURED PRODUCTS Mixers, Bypass Feeders, Filter Feeders, Bromine Feeders, Sample Coolers, Sludge Traps, Separators, Clean Tower Separator Systems, Tank Stands, Tank Package Systems, Glycol Feed Systems, Coupon Racks, Control Stations, NEMA Enclosures, Custom Packaged Systems and Specialty Welding P.O. Box 6207 Garden Grove, CA / 800 Monarch St. Garden Grove, CA Phone (74) Fax (74) Northern California Region (50) Southwest Region (602) customerservice@jlwingert.com O&M Manual INT0522.D /08
2 CONTENTS: PAGE.0 INTRODUCTION 2.0 WARRANTY 3.0 UNPACKING 4.0 MODEL NUMBER VERIFICATION LOCATION AND ENVIRONMENT INSTALLATION 3 6. BASIN CLEANSING SIDE STREAM CLEANSING ELECTRICAL START-UP AND OPERATION MAINTENANCE & SERVICING 5 9. CHECKING FOR LEAKS AND WEAR SERVICING THE RECOVERY TANK SERVICING THE MOTORIZED PURGE KIT PARTS LISTING 7.0 INTRODUCTION Wingert CT Series Separator System are self contained and designed to remove solids from sump basins or closed loop systems. The system includes a pump, pump strainer, separator, recovery tank, control panel and all necessary interconnecting plumbing. Standard flow rates from 38 to 200 GPM at 90 TDH allow for use in basins small and large. When coupled with the tower basin eductors, this systems is ready to clean even the toughest of applications. 2.0 WARRANTY Wingert CT Systems are warranted against manufacturing defects in material and workmanship for one year from the date of shipment. Applications outside the service for which the product is designed will automatically void any warranty. J.L. Wingert Co. will repair or replace a defective unit when returned to the factory with transportation prepaid. Final determination will be made upon inspection at receipt. J.L. Wingert Co. assumes no liability for labor and/or other expenses in making repairs or adjustments. All replacements will be F.O.B. factory. There are no other implied or expressed warranties. Motors and gear reducers are not manufactured by J.L. Wingert Co. and thus are warranted by the original manufacturer. Repair or replacement is contingent upon inspection and determination by the original manufacturer. Their findings are final and beyond our control. 3.0 UNPACKING Wingert CT Systems are assembled and ready for installation. Systems are shipped from the factory bolted to a shipping pallet. Inspect shipment upon receipt for any physical damage. The factory must be notified within 3 days after receipt of any discrepancies. If any product is damaged due to freight handling, contact the freight carrier to register a claim and contact the factory immediately for further assistance. NOTE: Most freight carriers only allow 3-5 days after receipt of goods to file a freight claim. Page
3 4.0 MODEL NUMBER VERIFICATION CT / (460) OPTIONS (460) MPK 460V, 3 phase, 60 hertz main power supply - in place of standard 230, 3 phase, 60 hertz Motorized purge kit in place of standard recovery tank FLOW RATE & SIZE TDH, " separator, 2HP pump TDH, /4" separator, 3HP pump TDH, /2" separator, 5HP pump TDH, 2 /2" separator, 7.5HP pump TDH, 3" separator, 7.5HP pump TDH, 3" separator, 0HP pump TDH, 4" separator, 5HP pump TDH, 4" separator, 20HP pump TDH, 5" separator, 30HP pump TDH, 6" separator, 40HP pump MODEL CT Clean Tower Separator, Pump and Recovery Tank System 5.0 LOCATION AND ENVIRONMENT Wingert Clean Tower Systems are designed to be placed outdoors, but consideration should be taken for any adverse conditions. When these conditions arise, the separator package should be placed under an awning or covered with a shed. Page 2
4 6.0 INSTALLATION Wingert Clean Tower Systems come pre-plumbed with the inlet and outlet isolation valves. Locate the system near the basin or line to be cleaned. Suction and discharge piping should be kept as short as possible. The CT system should be placed on a firm, level surface that will not degrade or collapse over time. There are three main types of installations that can be done. Follow the diagrams to install the plumbing in an orderly fashion, avoiding high and low piping configurations, long runs and multiple bends or elbows. 6. BASIN CLEANING When cleaning the basin, the pump suction and discharge are very critical. Because the suction can very rarely be flooded, a small high point should be plumbed preceding the pump suction. This is done to ensure that the pump will prime when started. Then the discharge should be plumbed to an appropriate opposing side to aid in sweeping the settled debris to the suction plumbing. This installation can be completed by using Wingert Tower Basin Eductors. Page 3
5 6.2 SIDE STREAM CLEANSING INSTALLATION # The preferred method for side stream cleaning is acheived by installing the separator system across the recirculation pump. This type of installation allows for maximum pressure drop through the separator. The diagram to the right depicts this type of installation. INSTALLATION #2 Another acceptable installation is the return to the system flow line. This type of installation only allows for the pressure drop that the separator system pump can provide. Although this is sufficient for separation, the greater the pressure drop - the better the separation. The diagram to the left depicts this type of installation. Page 4
6 7.0 ELECTRICAL BE SURE THAT POWER IS DISCONNECTED BEFORE SERVICING Once you are sure that the control power has been disconnected, open the control panel, and located behind the front door in RED letters is the main power supply. Consult factory if this is not the desired or available voltage. Have qualified personnel or an electrician place the power supply to the first three terminals (follow diagram located in control panel). Optionally the CT system can be wired to initiate with a remote or automatic signal. This signal is a switch closure of 0V, phase, 60 hertz and less than 5 amps. This can be done by placing a hot wire to terminal strip #2 pole #3 and the control wire to terminal strip #2 pole #4. Once the circuit is closed and maintained, the system will operate in an automatic fashion. Additionally, a service indicator remote signal or motorized purge signal can be wired to a control booth such that maintenance personnel can be alerted when service is needed or when the package is doing a blow down. This signal is also 5V, phase, 60 hertz and less than 5 amps. To get this signal to the control booth or external alarm, place a wire for neutral to terminal strip #2 pole # and a hot lead to terminal strip #2 pole #2. This connection needs to ground to the box or to the control booth panels. When finished with wiring, close and secure the control panel. Make sure all electrical connections are in compliance with local codes and that outdoor installations have no open exposures. 8.0 START-UP AND OPERATION Before starting the system up, check that all valves are open, all latches on the recovery tank and the pump strainer are secure. When ready, turn the main power switch to ON and the green indicator light will then come on. To prime the system and remove the air, turn the system switch to H or hand. The pump will energize and the system will begin to flow. Visually check all components for leaks that may have developed in shipment. Once flow has been establish for a few minutes and there is no sign of leaks, begin to remove the air from the system via the air release valves on the pump strainer and recovery tank. 9.0 MAINTENANCE & SERVICING Once in operation, the only maintenance that is needed for the Clean Tower Systems that have the standard recovery tank is a periodic check for leaks, wear, and a cleaning of the recovery tank and pump inlet strainer. When you service the recovery tank, it is always best to clean the pump pre-strainer although this is not a requirement. Page 5
7 9. CHECKING FOR LEAKS AND WEAR Checking the system at the threaded and flanged fittings for leaks is essential to the performance of any piping system. Leaks can cause external corrosion when the system is not in use and allow air pockets to develop. When the system has been installed and is running, it will develop a pressure drop. A pressure drop is the systems way of settling the solids through the separation chamber. Typically the first item to show wear will be the pump impeller. Once the pump impeller starts to wear, the pressure drop will start to recede. To monitor this, mark the pressure gauges where the pressure drop has been established in the system. After doing this, any deviations noted from these markings either means that the impeller is wearing, that the recovery tank needs servicing or that the separator has become clogged. 9.2 SERVICING THE RECOVERY TANK The required servicing is indicated on the control panel by the service light. This means that the recovery tank has become full and needs to be cleaned out. Once this light has come on there are two types of servicing. ) The recovery tank can be serviced, while in operation, by closing the isolation valves, opening the drain valve and the air release valve. Once the recovery tank is empty, the four (4) securing clamps can be opened and the lid removed. Remove the basket and filter by the basket handles. Discard and rinse out solids collected. Replace and return the recovery basket and filter. Secure the four hook latches and close the drain valve. Open the isolation valves and close the air release valve after purging the air from the recovery tank. At this point the service light should go off. 2) (RECOMMENDED) Once the recovery tank has become full, it is assumed that the pump strainer should have caught some, if not a lot, of large debris. To service the recovery tank and pump strainer, the systems power needs to be turned off and the system isolation valves need to be closed. The system can then be drained by opening the strainer drain valve and the recovery tank drain valve. Opening both of the air release valves aids in this process. Once the system has been drained, open the strainer and recovery tank latches and clean the strainer. Once cleaned, replace the strainer and filter, secure the latches and close the drain valves. Open the isolation valves and turn the system power on. Once flow has been established, close the air release valves after the air has been purged from the system. 9.3 SERVICING THE MOTORIZED PURGE KIT The required servicing for the motorized purge kit will have to be on a maintenance schedule. The amount of dirt in the environment dictates how often the valve will need to checked for wear and how it is sealing. Because the dirt and system water is being discarded, the trap or waste filter will have to be checked or installed so that the plumbing does not clog. Page 6
8 0.0 SYSTEM PARTS MODEL CT RT XTI CT RT XTI-025 CT RT XTI CT RT XTI-0250 CT RT XTI-0300 CT RT XTI-0300 CT RT XFD-0400 CT RT XFD-0400 CT RT XFD-0500/6 CT RT XFD through comes wired for 230/3/60. Add "-460" for wiring on 460/3/60 2 Add "-MPK" to the end of the control panel part number for motorized purge kit controls. 3 Consult factory for replacement parts on motorized purge kits. 0. RECOVERY TANK PARTS MODEL 2 3 4* RT PE RT PE RT PE * Sold individually 0.2 PUMP STRAINER PARTS MODEL 2 3* * Sold individually Page 7
SAMPLE COOLER and SLUDGE TRAP OPERATION & MAINTENANCE MANUAL
SAMPLE COOLER and SLUDGE TRAP OPERATION & MAINTENANCE MANUAL PLEASE RECORD THE FOLLOWING DATA (Information is located on the product label or packing slip) Product: Model No: Serial No: Installation Date:
More informationSEPARATOR PURGE KIT OPERATION & MAINTENANCE MANUAL
SEPARATOR PURGE KIT OPERATION & MAINTENANCE MANUAL PLEASE RECORD THE FOLLOWING DATA (Information is located on the product label or packing slip) Model Number: Service: Code: Installation Date: Installation
More informationCOMPACT GLYCOL FEED SYSTEMS OPERATION & MAINTENANCE MANUAL
COMPACT GLYCOL FEED SYSTEMS OPERATION & MAINTENANCE MANUAL Model Number: Service: Serial Number: Installation Date: Installation Location / Application: PLEASE RECORD THE FOLLOWING DATA (Information is
More informationGENERAL PURPOSE MIXERS
GENERAL PURPOSE MIXERS OPERATION & MAINTENANCE MANUAL PLEASE RECORD THE FOLLOWING DATA (Information is located on the product label or packing slip) Model Number: Code: Installation Date: Installation
More informationGLYCOL FEED SYSTEMS OPERATION & MAINTENANCE MANUAL
GLYCOL FEED SYSTEMS OPERATION & MAINTENANCE MANUAL PLEASE RECORD THE FOLLOWING DATA (Information is located on the product label or packing slip) Model Number: Date Code: Installation Date: Installation
More informationSeparator Systems Operations & Maintenance Manual
Separator Systems Operations & Maintenance Manual Record Your Model, Serial Number and Other Information on the back of this document. Manufacturing: Bypass & Filter Feeders, Glycol Feed Packages, Separators
More informationCentrifugal Separator Operations & Maintenance Manual
Centrifugal Separator Operations & Maintenance Manual Record Your Model, Serial Number and Other Information on the back of this document. Manufacturing: Bypass & Filter Feeders, Glycol Feed Packages,
More informationBypass / Filter Feeders Operations & Maintenance Manual
Bypass / Filter Feeders Operations & Maintenance Manual Record Your Model, Serial Number and Other Information on the back of this document. Manufacturing: Bypass & Filter Feeders, Glycol Feed Packages,
More informationCorrosion Coupon Rack Operations & Maintenance Manual
Corrosion Coupon Rack Operations & Maintenance Manual Record Your Model, Serial Number and Other Information on the back of this document. Manufacturing: Bypass & Filter Feeders, Glycol Feed Packages,
More informationProFlo FatBoy
The Standard For Professional Grade Diaphragm Pumps. ProFlo 3300 5500 FatBoy Operational and Installation Guidelines, Repair & Parts Contents 3300 5500 Fatboy Operational and Installation Guidelines...2
More informationS003 LIQUID LEVEL FLOAT SWITCH. Single or Multi-Point, Vertically-Mounted, Liquid Level Float Switch INSTALLATION AND OPERATIONS MANUAL
S003 LIQUID LEVEL FLOAT SWITCH INSTALLATION AND OPERATIONS MANUAL Single or Multi-Point, Vertically-Mounted, Liquid Level Float Switch READ THIS MANUAL PRIOR TO INSTALLATION This manual provides information
More informationStormPro BA Series Sump Pump
Page 1 of 8 Marks & Meanings DANGER: Keep the pump equipment out of the reach of children! Warns that the failure to follow the directions given could cause serious risk to individuals or objects. WARNING:
More informationREAD THIS MANUAL CAREFULLY BEFORE USING THE PUMP
OWNER S MANUAL Pond Pump READ THIS MANUAL CAREFULLY BEFORE USING THE PUMP Important Notice: This manual contains important information about the installation, operation and safe use of this product. This
More informationIndustrial Gly-Pack Feed Systems Operations & Maintenance Manual
Industrial Gly-Pack Feed Systems Operations & Maintenance Manual Record Your Model, Serial Number and Other Information on the back of this document. Manufacturing: Bypass & Filter Feeders, Glycol Feed
More informationESE Series Cast Iron Sewage Pumps
Owner s Manual ESE Series Cast Iron Sewage Pumps TABLE OF CONTENTS General Safety.................... 2 Specifications..................... 3 Installation.................... 4 & 5 Troubleshooting...................
More informationQUICK START GUIDE OWNER S MANUAL AL50 SERIES SAND FILTRATION TECHNOLOGY PLEASE CALL DO NOT RETURN TO STORE
QUICK START GUIDE OWNER S MANUAL SAFETY, INSTALLATION, OPERATION & PARTS AL50 SERIES SAND FILTRATION TECHNOLOGY PLEASE CALL 877-278-2797 DO NOT RETURN TO STORE! WARNING This equipment must be installed
More informationAccess Riser Fits PRO370 and PRO380 Series
Installation Manual 7171000D Access Riser Fits PRO370 and PRO380 Series Contents 1.) General Information 2.) Installation 3.) Optional 2 Installation Kits 4.) Typical Installation Diagram 5.) Junction
More informationL-Series: LIQUID LEVEL FLOAT SWITCH. Single-Point, Vertically-Mounted Liquid Level Float Switch INSTALLATION AND OPERATIONS MANUAL
L-Series: L001, L002, L003, L170, L175, L176, L177, L178, L180, L190 AND L195 LIQUID LEVEL FLOAT SWITCH INSTALLATION AND OPERATIONS MANUAL Single-Point, Vertically-Mounted Liquid Level Float Switch L001
More informationPowerFLO 7800 Series 12 Volt DC Motor-Driven Diaphragm Pumps
Installation Operation Repair Parts PowerFLO 7800 Series 12 Volt DC Motor-Driven Diaphragm Pumps Specifications Motor Type: 12 VDC, permanent magnet, totally enclosed, non-ventilated Leads: 14 AWG, 12
More informationJET METER INSTRUCTIONS
UNPACKING Please open and inspect your package upon receipt. Your package was packed with great care and all the necessary packing materials to arrive to you undamaged. If you do find an item that is broken
More informationPUMP VAULT S.T.E.P. SYSTEM
Installation and Service Manual PUMP VAULT S.T.E.P. SYSTEM NOTE! To the installer: Please make sure you provide this manual to the owner of the equip ment or to the responsible party who maintains the
More informationModel 8309WC Barrier Free Shower & Eye/Face Wash
INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS 1455 Kleppe Lane Sparks, NV 89431-6467 (775) 359-4712 Fax (775) 359-7424 E-mail: haws@hawsco.com website: www.hawsco.com Model 8309WC Barrier Free Shower
More informationMatala. VersiFlow Series. Instruction and Maintenance Manual
VersiFlow Series High Flow Multi-Purpose "Versatile " Pump V-3200 1/5HP 150W / Discharge 2 V-3900 1/3HP 250W / Discharge 2 V-4700 1/2HP 400W / Discharge 2 V-5600 1HP 750W / Discharge 2 Instruction and
More informationModel 8309WC Barrier Free Shower & Eye/Face Wash
INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS 1455 Kleppe Lane Sparks, NV 89431-6467 (775) 359-4712 Fax (775) 359-7424 E-mail: haws@hawsco.com website: www.hawsco.com No. 2067461(15) Model 8309WC
More informationPowerFLO 5800/5900 Series
PowerFLO 5800/5900 Series 5830/5930: 3.0 GPM 5836/5936: 3.6 GPM Inches (mm) Bypass Models Demand Models Switch 1.87 (47.5) 7.58 (192.5) 7.58 (192.5) 9.08 (230.6) 5840/5940: 4.0 GPM 5850/5950: 5.0 GPM Inches
More informationSurface Mounted Bottle Fillers
BF & BF6 Series Surface Mount Bottle Fillers BF Series BF6 Series TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER:.800.9.960 Technical Assistance Fax:.66.8.89 NOTES TO INSTALLER:. Please leave this documentation
More informationOwner s Manual SMT PORTABLE SERIES IMPORTANT DOCUMENT - DO NOT DISCARD 600PE 1100PE 1100HC. SprayMasterTech.com. Date Manufactured: / / 600PE 1100PE
SMT PORTABLE SERIES 600PE 1100PE 1100HC SprayMasterTech.com Owner s Manual You have just purchased one of the best spray washers on the market today. It incorporates the very latest in technological advances.
More informationNECO Pumping Systems
INSTALLATION OPERATION & MAINTENANCE INSTRUCTIONS For Your NECO Pumping Systems PACKAGED CIRCULATING SYSTEM THIS COMPLETELY ASSEMBLED, TESTED, PACKAGED CIRCULATING SYSTEM IS OF THE HIGHEST QUALITY AND
More informationL007 LIQUID LEVEL FLOAT SWITCH. Side-Mounted Liquid Level Float Switch INSTALLATION AND OPERATIONS MANUAL
L007 LIQUID LEVEL FLOAT SWITCH INSTALLATION AND OPERATIONS MANUAL Side-Mounted Liquid Level Float Switch READ THIS MANUAL PRIOR TO INSTALLATION This manual provides information on the L007 Side- Mounted
More informationPRE-PLUMBED SEWAGE SYSTEM
PRE-PLUMBED SEWAGE SYSTEM Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. MODEL #1910-0009 Español p. 13 ATTACH YOUR RECEIPT HERE Serial Number Purchase Date Questions, problems,
More informationCondensate Pump. Installation and Safety Instructions CP-22 CP CP-22LP CP-22LP-230
Condensate Pump Installation and Safety Instructions CP-22 CP-22-230 CP-22LP CP-22LP-230 CP-22 CP-22LP CP-22T CP-22LPT CP-22-230 CP-22LP-230 CP-22T-230 CP-22LPT-230 Rated Voltage 120 Volts / 60 Hz 220
More informationCondensate Pump. Installation and Safety Instructions CP-22 CP CP-22LP CP-22LP-230
Condensate Pump Installation and Safety Instructions CP-22 CP-22-230 CP-22LP CP-22LP-230 CP-22 CP-22LP CP-22T CP-22LPT CP-22-230 CP-22LP-230 CP-22T-230 CP-22LPT-230 Rated Voltage 120 Volts / 60 Hz 220
More informationSEWAGE PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 14
SEWAGE PUMP Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. MODEL #1261-0001 Español p. 14 ATTACH YOUR RECEIPT HERE Serial Number Purchase Date Questions, problems, missing parts?
More informationDRAIN PUMP SYSTEMS MODELS 104*, 105, 110, 115, 120, 131
Notice to Installer: Instructions must remain with installation. Product information presented here reflects conditions at time of publication. Consult factory regarding discrepancies or inconsistencies.
More informationUSER S MANUAL FOR F & Q. Submersible Sewage Pumps
USER S MANUAL FOR F & Q Submersible Sewage Pumps 50WQ Series The F&Q pumps are carefully inspected and tested to ensure operating performance and safety. However, failure to follow the instructions and
More informationAir Curtain. Installation, Operating and Maintenance Instructions
Installation, Operating and Maintenance Instructions Save this manual for future reference. Air Curtain Model Numbers: ES026, ES036, ES042, ES048, ES060, ES072 READ THIS OWNER S MANUAL CAREFULLY BEFORE
More informationPressurized Bead Filters
Pressurized Bead Filters Installation Instructions Table of Contents Safety Information Installation Assembly Start Up Maintenance Troubleshooting Warranty Safety Information: 1. Installation should be
More informationInstallation Manual. D3600- Series Duplex Grinder Systems. Contents
Installation Manual 7353000E D3600- Series Duplex Grinder Systems Features: 36 Diameter Fiberglass Tank Available in 48, 60, 72, 84, and 96 heights LSG Single or LSGX 2 Stage 2HP Grinder Pumps Factory
More informationInstallation, Operation and Maintenance Manual
Installation, Operation and Maintenance Manual Manual Polymer Makedown Systems Manufacturers of Quality Pumps, Controls, and Systems Standard Product Operations 27101 Airport Rd., Punta Gorda, FL 33982
More informationUSER S MANUAL FOR F & Q. Submersible Sewage Pumps
USER S MANUAL FOR F & Q Submersible Sewage Pumps 100WQ Series The F&Q pumps are carefully inspected and tested to ensure operating performance and safety. However, failure to follow the instructions and
More informationF-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide
F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide 11451 Belcher Road South, Largo, FL 33773 USA Tel +1 (727) 447-6140 Fax +1 (727) 442-5699 1054-7 / 34405 www.onicon.com sales@onicon.com
More informationManual for 12 Sand Filter/ Pump Combo Unit.
Manual for 12 Sand Filter/ Pump Combo Unit. MODELS: CC2013/CC2015 SAFETY INFORMATION 1. The sand filters are designed to work with water at temperature>than 0 and
More information2460 / 2472 / Series Simplex Grinder Systems
Installation Manual 5651000I 2460 / 2472 / 2484 - Series Simplex Grinder Systems Features: LSG or LSGX Series 2HP Grinder Pump 24 dia. Basin available in 60, 72, or 84 depths Guide Rail System Preassembled
More informationD-Series Blowers and Exhausters
Operation and Maintenance Manual D-Series MONOXIVENT - SOURCE CAPTURE SYSTEMS - info@ Oct. - 2015 MONOXVENT BLOWERS AND EXHAUSTERS D05-1 D05-3 D10-1 D10-3 D15-1 D15-3 D20-1 D20-3 D30-1 D30-3 ½ HP TEFC
More informationGeyserMax-Flow Series
GeyserMax-Flow Series 115V/60Hz Waterfall Pump GM-3900 1/5HP 150W / Discharge 1-1/2 GM-4700 1/3HP 250W / Discharge 2 GM-5400 1/2HP 400W / Discharge 2 GM-6200 3/4HP 750W / Discharge 2 230V/50Hz GM-3800
More informationPPM EO-100 TM. Operation Manual
PPM EO-100 TM Open Loop Electric Prewet Power Module Operation Manual Rev A Page 1 2/23/2010 Copyright 2008 by Cirus Controls, LLC. All Rights Reserved. No part of this material may be reproduced in any
More informationStormPro BCV400 Sewage Ejector Pump
Page 1 of 8 Marks & Meanings DANGER: Keep the pump equipment out of the reach of children! Warns that the failure to follow the directions given could cause serious risk to individuals or objects. WARNING:
More informationTECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER TECHNICAL ASSISTANCE FAX:
ACORN SAFETY P.O. BOX CITY OF INDUSTRY, CA -0 UNITED STATES OF AMERICA WWW.ACORNSAFETY.COM INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS EYEWASH / FACEWASH Models S00 / S00 / S00 / S00-CS-SSE /
More informationDRAIN PUMP SYSTEM MODEL 105 (Korean) INSTALLATION INSTRUCTIONS PREINSTALLATION CHECKLIST
Notice to Installer: Instructions must remain with installation. Your Peace of Mind is Our Top Priority Product information presented here reflects conditions at time of publication. Consult factory regarding
More informationFor a 25 Amp Circuit with a 10% Voltage Drop, we recommend the following [but please follow all local electrical codes]: 50 [15.2] 8 [8.
SHURFLO 5000 Series Pumps SHURflo offers various pumps models for different applications. The information outlined by this manual is general, and not specific to all 5000 series pumps. Contact SHURFLO
More informationInstallation Manual. Q Series Quadplex Grinder Systems. Contents
Installation Manual 7759000A Q4800 - Series Quadplex Grinder Systems Features: 48 Diameter Fiberglass Tank Available in 84, 96, and 120 heights LSG Single or LSGX 2 Stage 2 HP Grinder Pumps Factory Installed
More informationModel No. LG55-3PT 55 Gallon Sprayer 3 Point Lawn & Garden Sprayer Model No. LG27-3PT 25 Gallon Sprayer GENERAL INFORMATION
5300587 Model No. LG27-3PT 25 Gallon Sprayer 5300576 Model No. LG55-3PT 55 Gallon Sprayer 3 Point Lawn & Garden Sprayer Join the center boom to the carrier frame with the two u-bolts, and flange locknuts.
More informationManual Transfer Switch
Manual Transfer Switch Instruction Manual 30 1200 Amp 2, 3 & 4 Pole Page 1 WARNING Before Installation READ THIS MANUAL carefully to learn how to properly install, operate and maintain this unit. Personal
More informationOWNER S MANUAL. Model: LG-30-TRL ( ) (30 Gallon Lawn & Garden Trailer Sprayer)
OWNER S MANUAL Model: LG-30-TRL (5302317) (30 Gallon Lawn & Garden Trailer Sprayer) Technical Specifications 30 Gal. Corrosion-Resistant Polyethylene Tank 12 Volt Diaphragm Pump, 2.1 g.p.m. 60 psi 15 Ft.
More informationGeneral Installation Instructions for Valves and Gates
General Installation Instructions for Valves and Gates Thank you for your purchase of a Lorenz valve. We appreciate your business! Please read this installation manual and follow recommended safety precautions.
More informationTITAN FLOW CONTROL, INC.
PREFACE: TITAN FLOW This manual contains information concerning the installation, operation, and maintenance of Titan Flow Control (Titan FCI)Full Body Swing Check Valves. To ensure efficient and safe
More informationWestell FUSE PANEL. Technical Practice N Position Type VDC Floating
530-101760 REV C 0808-03C December 7, 2012 Westell FUSE PANEL Technical Practice 180108-N-0808 8 Position Type 70 130 VDC Floating FEATURES Single floating input distributing power via Type-70 fuses each
More informationModel 8346/8346CRP Shower & Eye/Face Wash
INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS 1455 Kleppe Lane Sparks, NV 89431-6467 (775) 359-4712 Fax (775) 359-7424 E-mail: haws@hawsco.com website: www.hawsco.com No. 2080177(15) Model 8346/8346CRP
More informationUser s Manual D-Series Blowers and Exhausters
User s Manual D-Series Blowers and Exhausters D05-1 ½ HP TEFC 115/230 VOLTS, 1 PH D05-3 ½ HP TEFC 208/230/460 VOLTS, 3 PH D10-1 1 HP TEFC 115/230 VOLTS, 1 PH D10-3 1 HP TEFC 208/230/460 VOLTS, 3 PH D15-1
More informationDilution Control Systems. 2-Button Station Model OPERATION SERVICE PARTS CARE
Dilution Control Systems 2-Button Station Model 421090 OPERATION SERVICE PARTS CARE Note: 2-Button Station comes in two separate cartons identified as Carton 1 and Carton 2. Revised 1/02 2-Button Station
More informationTALCO FIRE SYSTEMS. LSF Start-Up Instructions. 1) IMPORTANT: Inspect the unit for damage. Report any damage to the freight carrier immediately.
LSF Start-Up Instructions 1) IMPORTANT: Inspect the unit for damage. Report any damage to the freight carrier immediately. 2) PRE-START-UP: Be sure there is water in the pump. Bleed air at all high points
More informationOWNER S MANUAL. Model: FSUTL60-12V ( ) Technical Specifications. Assembly Instructions
OWNER S MANUAL Model: FSUTL60-12V (5301421) (60 Gallon Lawn & Garden Utility Sprayer - Boom-Ready) Technical Specifications 60 Gal. Corrosion-Resistant Polyethylene Tank Deluxe Pistol-Grip Handgun 25 Ft.
More informationOWNER S MANUAL. Model: FSUTL40-12V ( ) Technical Specifications. Assembly Instructions
OWNER S MANUAL Model: FSUTL40-12V (5301420) (60 Gallon Lawn & Garden Utility Sprayer - Boom-Ready) Technical Specifications 40 Gal. Corrosion-Resistant Polyethylene Tank Deluxe Pistol-Grip Handgun 25 Ft.
More informationInstallation, Operation, Repair and Parts Manual
Self-Priming Adaptor Form L-1516 (3-08) Installation, Operation, Repair and Parts Manual Description Self-priming adaptor (SPA) is a low pressure tank that provides air separation from the liquid being
More informationA171 Series Barrier Free, Wall Mounted Fountain
Series Barrier Free, Wall Mounted Fountain 100F / 400F / 100S / 400S TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER: 1.800.591.9360 Technical Assistance Fax: 1.626.855.4894 NOTES TO INSTALLER: 1. Please
More informationMODEL 900 IMPELLER-TYPE FLOW METER
MODEL 900 IMPELLER-TYPE FLOW METER - For Water Applications - INSTALLATION & INSTRUCTION MANUAL 8635 Washington Avenue Racine, Wisconsin 53406 Toll Free: 800.235.1638 Phone: 262.639.6770 Fax: 262.417.1155
More informationGLYCOL SYSTEM MONITOR (GSM)
GLYCOL SYSTEM MONITOR (GSM) The Future of Beer System Diagnostics Glycol cooling systems are typically overlooked by most resturaunts. However, when the unit(s) are performing poorly or there is a component
More informationOWNER S MANUAL EVOLUTION 3500, 4500, 5500, & 8500 SERIES PUMPS
OWNER S MANUAL EVOLUTION 3500, 4500, 5500, & 8500 SERIES PUMPS IMPORTANT SAFETY INSTRUCTIONS When installing and using this electrical equipment, basic safety precautions should always be followed, including
More informationTITAN FLOW CONTROL, INC.
PREFACE: This manual contains information concerning the installation, operation, and maintenance of Titan Flow Control (Titan FCI) Wafer Style, Dual Plate Check Valves. To ensure efficient and safe operation
More informationOwner s Manual Drill and Light Weight Portable Utility Pumps
Owner s Manual Drill and Light Weight Portable Utility Pumps PUP61 Light Weight Utility Pump PUP62 Drill Pump with Kit PUP63 Drill Pump PUP61DC Light Weight Utility Pump LIMITED WARRANTY This pump is warranted
More informationINSTALLATION AND OPERATION MANUAL
INSTALLATION AND OPERATION MANUAL Models S120U & S240U Read all instructions before assembling or using the SunHeater system. Retain this manual for future use. TABLE OF CONTENTS Important Safety Information...2
More informationManual. Economy Glycol Feeder. Installation Maintenance Repair Manual
Manual Economy Glycol Feeder Installation Maintenance Repair Manual Advantage Controls P.O. Box 1472 Muskogee, OK 74402 Phone: 800-743-7431 Fax: 888-686-6212 www.advantagecontrols.com email: support@advantagecontrols.com
More informationSand Filtration System
Sand Filtration System Owners Manual Installation, Operation, and Parts SHOW FILTRATION SYSTEM SAVE THIS INSTRUCTION MANUAL Note: Use only High Rate Sand No. 20 Silica Sand (.45mm -.55) specifically manufactured
More informationSeries: PFUEG 1/12HP, 5000 RPM, 60 Hz Utility Pumps
INSTALLATION MANUAL Series: 1/12HP, 5000 RPM, 60 Hz ISP No: - 6/09 General Safety Information Before installation, read the following instructions carefully. Failure to follow instruction and Safety information
More informationFord Meter Box Test Bench Installation Instructions
DQS Inc. 12/12/18 THE FORD METER BOX COMPANY, INC. CERTIFIED TO ISO 9001:2015 10004466 Ford Meter Box Test Bench Installation Instructions Table of Contents Installation Instructions for Standard, Akron
More informationPreSoak System (NonFoaming) DU PS1-HP DU PS6-HP
PreSoak System (NonFoaming) DU PS1-HP DU PS6-HP Serial Number: Owner s Manual #0786 040810 Installation Date: Please read and u n d e r s t a n d t h i s manual. Store in safe location for future reference.
More informationWELDING FUME EXHAUSTERS & ARMS
WELDING FUME EXHAUSTERS & ARMS The Ace 75 Series is our flexible and effective line of welding fume exhausters and extraction arms for shops that elect to exhaust their weld fumes outdoors instead of through
More informationSEPTIC TANK PUMP VAULT FILTER SYSTEM PUMP VAULT INSTALLATION AND SERVICE MANUAL
SEPTIC TANK PUMP VAULT FILTER SYSTEM PUMP VAULT INSTALLATION AND SERVICE MANUAL NOTE! To the installer: Please make sure you provide this manual to the owner of the equip ment or to the responsible party
More informationRapid Digestor Fume Removal System
Rapid Digestor Fume Removal System Model 23500-20 Designed for 20 Place Block Digestors Model 23500-25 Designed for Rapid Digestor 25 Place Model 23540 Designed for Rapid Digestor 4 Place INSTRUCTION MANUAL
More informationHQZ & RBM MODEL LIFT & TRANSFERS
Technical Documentation HQZ & RBM MODEL LIFT & TRANSFERS Each serial number is unique to that specific conveyor and provides mk North America with complete order details. The conveyor serial number is
More informationHALLMARK INDUSTRIES INC
Performance Part No. HP. CONVERTIBLE JET PUMP USER S MANUAL GPH of Water @ Total Discharge Pressure of 40 psi Max. Pressure Max suction (shallow well) Max Suction (deep well) Max GPM (@0 head) Max Discharge
More informationInstallation Manual. Omnivore Grinder Pump Retrofit Unit LSG202-RE. LSGX202-RE 2Hp, V, 1 phase, Automatic LSG202-REX
Installation Manual 5672000E Omnivore Grinder Pump Retrofit Unit FOR E-ONE* GP200, GP2000 AND EXTREME SERIES Models to replace GP200 and GP2000: LSG202-RE 2Hp, 208/230V, 1 phase, Automatic LSGX202-RE 2Hp,
More information2 INLET / HIGH HEAD DRAIN PUMP SYSTEMS MODELS , INSTALLATION INSTRUCTIONS PREINSTALLATION CHECKLIST
Product information presented here reflects conditions at time of publication. Consult factory regarding discrepancies or inconsistencies. MAIL TO: P.O. BOX 1637 Louisville, KY 06-037 SHIP TO: 369 Cane
More informationModel 8300 & 8300CRP Shower/Eyewash
INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS 1455 Kleppe Lane Sparks, NV 89431-6467 (775) 359-4712 Fax (775) 359-7424 HAWS AG Bachweg 3 CH-3401 Burgdorf Switzerland Haws Mfg. Pte Lt. 2A Sungei Kadet
More informationPR 20/20. WARNING Buyer/User assumes all responsability for safety and proper use not in accordance with the directions and sately labels.
WARNING Buyer/User assumes all responsability for safety and proper use not in accordance with the directions and sately labels. Equipped ready to use Variable flow water pump Intake and output tubing
More informationUniversal Bevel Drives Service Manual
Engineering Service Bulletin #SB241202 Universal Bevel Drives Service Manual Cautions Following are some general cautions. All personnel shall use safe and sound practices and take all necessary precautionary
More informationTECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER TECHNICAL ASSISTANCE FAX:
ACORN SAFETY P.O. BOX 3527 CITY OF INDUSTRY, CA 91744-0527 UNITED STATES OF AMERICA WWW.ACORNSAFETY.COM INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS COMPACT RECESSED EYEWASH/FACEWASH MODELS S0560
More informationFUNNEL CAKE FRYER Instruction Manual Models: 8078 / FC-4, 8082 / FC-6, and 8090 / FC-4
Part No. 89784 Revised: December 2005 FUNNEL CAKE FRYER Instruction Manual Models: 8078 / FC-4, 8082 / FC-6, and 8090 / FC-4 Cincinnati, OH 45241-4807 USA GAS SAFETY PRECAUTIONS INSTALLATION INSTRUCTIONS
More informationInstallation, Operation and Maintenance Manual SCP/SFP SELF PRIMING PUMPS
Installation, Operation and Maintenance Manual SCP/SFP SELF PRIMING PUMPS IMPORTANT - WARRANTY CLAUSE ROTECH PUMPS: Pumps manufactured & assembled by Rotech, are covered by warranty for free of manufacturing
More informationREAD THIS MANUAL CAREFULLY BEFORE USING THE PUMP
OWNER S MANUAL Swimming Pool Pump READ THIS MANUAL CAREFULLY BEFORE USING THE PUMP Important Notice: This manual contains important information about the installation, operation and safe use of this product.
More informationTECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER TECHNICAL ASSISTANCE FAX:
ACORN SAFETY P.O. BOX 3527 CITY OF INDUSTRY, CA 91744-0527 UNITED STATES OF AMERICA WWW.ACORNSAFETY.COM INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS DECK MOUNTED EYE/FACEWASH Model S0730 / S0740
More informationItems # and #
D I S P E N S E R T E C H N I C A L M A N U A L Items #91160-00 and #91161-00 1. System Description... 1 2. Equipment Included with the Green Earth II XL System... 2 3. Components Included with Green Earth
More informationInstallation & Operating Manual
Installation & Operating Manual 25IPCC-M 7/08 Edition PC Series C E N T R I F U G A L Congratulations On Your Choice In Purchasing This Webtrol Pump Its Quality is unsurpassed in material and workmanship
More informationAqua Ultraviolet Sunami Series Pumps 1/3HP, 3/4HP, 3HP, 4HP, 5HP
TM 42371 Avenida Alvarado Temecula, CA 92590 TOLL FREE (800) 454-2725 TEL (951) 296-3480 FAX (951) 296-3490 www.aquauv.com Aqua Ultraviolet Sunami Series Pumps 1/3HP, 3/4HP, 3HP, 4HP, 5HP Sunami Warranty
More informationOWNER S MANUAL Spa & Jetted Bathtub Pump
OWNER S MANUAL Spa & Jetted Bathtub Pump READ THIS MANUAL CAREFULLY BEFORE USING THE SPECK PUMP Important Notice: This manual contains important information about the installation, operation and safe use
More informationMODEL NO. SK-61-12V 12 VOLT SKID MOUNTED LAWN & GARDEN SPRAYER ASSEMBLY / OPERATION INSTRUCTIONS / PARTS
5301304 MODEL NO. SK-61-12V 12 VOLT SKID MOUNTED LAWN & GARDEN SPRAYER ASSEMBLY / OPERATION INSTRUCTIONS / PARTS ASSEMBLY The sprayer is fully assembled at the factory. The only assembly necessary is to
More informationARAG Modular Electric Valve Operating Instructions and Parts Manual
ARAG Modular Electric Valve Operating Instructions and Parts Manual Description Form L-1479 (11/12) California Proposition 65 Warning -- This product and related accessories contain chemicals known to
More informationME3H/ME3F SERIES. Automatic and manual models. Single phase power only 115 or 230 volt.
ME3H SUMP/EFFLUENT PUMP ME3F SUMP/EFFLUENT PUMP ME3H/ME3F SERIES SUBMERSIBLE SUMP AND EFFLUENT PUMPS INSTALLATION AND SERVICE MANUAL Automatic and manual models. Single phase power only 115 or 230 volt.
More informationQWIK JON ULTIMA 204 SYSTEMS INSTALLATION INSTRUCTIONS PREINSTALLATION CHECKLIST
NOTICE TO INSTALLER: Instructions must remain with installation. SECTION: 6.10.065 Your Peace of Mind is Our Top Priority Product information presented here reflects conditions at time of publication.
More information100 Gallon Skid Sprayer
100 Gallon Skid Sprayer Model #: KS100P17 User Manual Read this manual for complete instructions Model #: KS100P17 Table of Contents Warranty... 3 General Safety Information... 3 Hazardous Substance Alert...
More information