Guying - Insulator Dimensional Requirements ** Lightning Protection & Grounding - Grounds
|
|
- Nathaniel Merritt
- 5 years ago
- Views:
Transcription
1 Standard Description ** Configurations - Single Phase, 4 to 15kV ** Configurations - Two or Three Phase Tangent or Angle on Wood Crossarm, 4 to 15 kv ** Configurations - Two or Three Phase Floating and 90 o Angles, 4 to 15 kv ** Configurations Two or Three Phase Buck Arm - 90⁰ Angle, 4 to 15 kv ** configurations - Two or Three Phase Loopovers, 4 to 15 kv ** Configurations - Single Circuit 34kV or 69 kv, Tangent ** Configurations - Double Circuit 34kV or 69 kv, Tangent Wildlife Protection - 25 kv and below, Cutout Cover ** Wildlife Protection - 25kV and below, Conductor Cover Single Pin ** Wildlife Protection - 25kV and below, Conductor Cover Double Pin ** Wildlife Protection - 25kV and below, Conductor Cover Deadend ** Inuslators and Supports- Pin and Insulator, Single Pin, 12 kv and Static ** Insulators and Supports - Deadends on Pole, 12 kv ** Inuslators and Supports- Horizontal Post Insulators, 69kV ** Fuses and Switches - Single Phase Sectionalizing Amp, 4 or 12 kv ** Fuses & Switches - Three Phase Sectionallizing, Amp, 4 or 12 kv ** Fuses and Switches - Three Phase Sectionalizing. 600 Amp, 4 or 12 kv ** Fuses & Switches - Single Phase Tap from Single Phase, 4 or 12 kv ** Fuses & Switches - Single Phase Tap from Three Phase, 4 or 12 kv ** Fuses & Switches - Two or Three Phase Tap, Crossarm Construction, 4 or 12 kv Guying - Insulator Dimensional Requirements ** Lightning Protection & Grounding - Grounds Transformers - 15kV and below-grounded Wye, 1-167kVa, Single Phase ** Transformers - 15kV and below-grounded Wye, Three Single Phase Cluster Mounted ** Cable Terminals - 15kV and Below Single Phase, #2 through 4/ ** Cable Terminals - 15kV and Below Three Phase, #2 through 4/0 Revision Date
2 CONFIGURATIONS Single Phase 4 to 15 kv ** Sheet 1 of 4 C1 D1 E1 F1 G1 B1 H1 A1 FACE OF POLE Tangent, Single Pin Tangent, Double Pin A,D Angle, Single Pin Angle, Double Pin Guy Pole Top Pin 1. See DCS for angle and span length limitations. 2. See DCS for unguyed composite pole application. 3. Composite pole has factory installed (internal) pole ground in quadrant B1, wood pole may require pole ground based on application. 4. See DCS ** for neutral configuration. 5. Use Pole eye plate Stk # on composite pole. 6. Double coil washer is not required on composite pole. Stnd. / Stk. No. Description ** A Insulator, Pole Top, Sgl Pin Insulator, Pole Top, Dbl Pin 1 1 D TT*W Single Top Tie ST*W Single Side Tie 1 DDT*W Double Top Tie 1 DST*W Doudle Side Tie 1 3.@ I Grounding Unit, Wood Pole Grounding Unit, Composite Pole @ J ** Guying Unit 1 1 K Neutral, Thru @ Neutral, Thru w/extension ENG: MJ REV. NO: 8 REV. DATE: 09/14/15
3 CONFIGURATIONS Single Phase 4 to 15 kv ** Sheet 2 of 4 C1 D1 E1 F1 G1 B1 H1 A1 FACE OF POLE B J 5 F 2 4 J 3 I Floating Angle 1 NOTES: 1. See DCS for angle limitations. 2. See DCS for unguyed composite pole application. 3. Composite pole has factory installed (internal) pole ground in quadrant B1. Wood pole may require pole ground based on application. 4. See DCS ** for neutral configuration. 5. Use pole eye plate Stk # on composite pole. Stnd. / Stk. No. Description ** 04 B Insulator, Floating Angle F SC*W Clamp, Suspension 1 3.@ I Grounding Unit, Wood Pole Grounding Unit, Composite Pole 1 5.@ J ** Guying Unit 2 4.@ K Neutral, Thru Neutral, Thru w/extension 1 ENG: MJ REV. NO: 8 REV. DATE: 09/14/15
4 CONFIGURATIONS Single Phase 4 to 15 kv ** Sheet 3 of 4 8 H C E G 8 C Guy Guy Guy W/FG Extension W/O FG Extension Deg. Angle W/FG Extension W/O FG Extension Deadend D D or H H G H 22 A E 22 5 B G I 3 I W/FG Extension W/O FG Extension Loopover W/FG Extension W/O FG Extension Tap ENG: MJ REV. NO: 8 REV. DATE: 09/14/15
5 CONFIGURATIONS Single Phase 4 to 15 kv ** Sheet 4 of 4 NOTES: 1. Use FG extension if application requires. 2. See DCS for unguyed composite pole application. 3. Composite pole has factory installed (internal) pole ground in quadrant B1. Wood pole may require pole ground based on application. 4. See DCS ** for neutral configuration. 5. Use pole eye plate Stk # on composite pole. 6. Double coil washer is not required on composite pole. Stnd. / Stk. No. Description ** A Pole Top, Loopover w/fg Extension Pole Top, Loopover w/o FG Extension C Deadend w/fg Extension Deadend w/o FG Extension 1 2 D TT*W Top Tie E DEC*W Clamp, Deadend G PG* See DCS H PLW*W Wire, Poly Covered, (ft.) I Grounding Unit, Wood Pole Grounding Unit, Composite Pole J ** Guying Unit K Neutral, Thru Neutral, Deadend Neutral, Corner Neutral, Thru w/tap 1 1 ENG: MJ REV. NO: 8 REV. DATE: 09/14/15
6 CONFIGURATIONS Two or Three Phase Tangent Or Angle On Wood Crossarm 4 to 15 kv ** Sheet 1 of 3 C, D B 12 A Guy 6 Tangent 8 Sgle. Arm Angle 8 Sgle. Arm Tangent 10 Sgle. Arm Angle 10 Sgle. Arm NOTES: 1. See DCS for angle and span length limitations. 2. See DCS ** for arm detail. 3. For 2 phase configuration, eliminate the center phase position. 4. See DCS for unguyed composite pole application. 5. Composite pole has factory installed pole ground; wood pole may require pole ground based on application. 6. See DCS ** for neutral configuration ft. crossarm available AmerenMO only. Stnd. / Stk. No. Description ** A Crossarm, 8 Sgl Crossarm, 10 Sgl B Insulator, Arm, Sgl C Insulator, Pole Top, Sgl D TT*W Sgl Top Tie ST*W Sgl Side Tie ENG: MJ REV. NO: 9 REV. DATE: 1/06/12
7 CONFIGURATIONS Two or Three Phase Tangent Or Angle On Wood Crossarm 4 to 15 kv ** Sheet 2 of 3 G A TANGENT 10 SGLE. ARM ANGLE 10 SGLE. ARM UNDERBUILD 3 2 NOTES: 1. See DCS for angle and span length limitations. 2. Underbuild cover available AmerenIL only. Stnd. / Stk. No. Description ** A Crossarm, 10 Sgle C Insulator, Arm E TT*W Top Tie, Sgl Pin 3 2 ST*W Side Tie, Sgl Pin 3 2 2@ G Cover Single Pin 1 1 ENG: MJ REV. NO: 9 REV. DATE: 1/06/12
8 CONFIGURATIONS Two or Three Phase Tangent Or Angle On Wood Crossarm 4 to 15 kv ** Sheet 3 of 3 D C,F B Guy TANGENT 8 SGLE. ARM ANGLE 8 SGLE. ARM ANGLE DBLE. ARM SIDE ARM NOTES: 1. See DCS for angle and span length limitations ft. alley arm available AmerenMO only. 3. Cover available AmerenIL only. Stnd./ Stk. No. Description ** B Sidearm, 8 Sgle Sidearm, 8 Dble. 1 1 C Insulator, Arm D Insulator, Pole Top E TT*W Top Tie 3 2 ST*W Side Tie 3 2 DST*W Double Side Tie 3 2 3@ F Cover Single Pin 1 1 ENG: MJ REV. NO: 9 REV. DATE: 1/06/12
9 CONFIGURATIONS Two or Three Phase Floating and 90 o Angles 4kV to 15kV ** Sheet 1 of 2 B F W/O EXTENSION W/EXTENSION J J K I 3 2 Floating Angle Deadend w/fg Extension Deadend w/o FG Extension ENG: MJ REV. NO: 6 REV. DATE: 10/19/11
10 CONFIGURATIONS Two or Three Phase Floating and 90 o Angles 4kV to 15kV ** Sheet 2 of 2 NOTES: 1. Use pole eye plate Stk # on composite poles. 2. See DCS for design limitations. 3. See DCS for unguyed composite pole application. 4. Composite pole has factory installed pole ground. Wood pole may require pole ground based on application. 5. See DCS ** for neutral configuration. 6. Guy attachment should be centered between phases and between phase and neutral. Stnd. / Stk. No. Description ** Ph 2 Ph A Insulator, Floating Angle 3 2 B Deadend w/fg Extension Deadend w/o FG Extension 2 D PG* See Std E DEC*W Deadend Clamp F SC*W Suspension Clamp 3 G PLW*W Wire, Poly covered, (Ft.) I Grounding Unit, Grounding Unit, Composite Pole J ** 5@ K Neutral, Corner Neutral, Tangent/Angle or 260 Install Connector or Jumper ENG: MJ REV. NO: 6 REV. DATE: 10/19/11
11 CONFIGURATIONS Two or Three Phase Buck Arm 90 o Angle 4 to 15kV ** Sheet 1 of 2 F F D E,G J D 2 3 E,G J D C 4 F D F D W/O EXTENSION D 1 E W/EXTENSION C J 1 0 D I H FG Arm, Pole w/o Ext FG Arm, Pole w/ext FG Arm, Pole w/o Ext FG Arm, Pole w/ext ENG: MJ REV. NO: 8 REV. DATE: 02/17/12
12 CONFIGURATIONS Two or Three Phase Buck Arm 90 o Angle 4 to 15kV ** Sheet 2 of 2 NOTES: 1. See DCS for arm strength. 2. Attach guy to bracket of fiberglass arm. 3. Use 10 deadend arm with F/G extension on pole for underbuild application. 4. For 2 phase construction, eliminate the center phase position. 5. See DCS for unguyed composite pole application. 6. Composite pole has factory (internal) installed pole ground; wood pole may require pole ground based on application, and underbuild uses existing pole ground crossarm available AmerenMo only. 8. Deadend on pole w/o fiberglass extension available AmerenMo only. 9. See DCS ** for neutral configuration. Stnd. / Stk. No. Description ** A Deadend Assy., F/G, Deadend Assy., F/G, C Deadend w/fg Extension Deadend w/o FG Extension 1 2 D Deadend on Arm E Insulator on Arm F PG* See Std G TT*W Top Tie, Sgl Pin DEC*W Clamp, Deadend @ H Neutral Deadend I Neutral PG Clamp J PLW*W Lead Wire,Poly Covered, Ft @ K Grounding Unit, Grounding Unit, Composite Pole @ L ** Guying 252 or 260 Install Connector or Jumper ENG: MJ REV. NO: 8 REV. DATE: 02/17/12
13 CONFIGURATIONS Two or Three Phase Loopovers 4 to 15kV ** Sheet 1 of 5 POLE TOP F/G ARM F C 7 C P W/EXTENSION C W/O EXTENSION G D A 8 K Deadend 8 Arm, Pole w/ext. Deadend 8 Arm, Pole w/o Ext. Deadend 10 Arm, Pole w/ext. Deadend 10 Arm, Pole w/o Ext. 5 I NOTES: 1. See DCS for arm strength. 2. Attach guy to center bracket of fiberglass arm for difference in tension. 3. For 2 phase construction, eliminate the center phase position 4. Contact Standards using unguyed composite pole for difference in conductor tension application. 5. Composite pole has factory (internal) installed pole ground; wood pole may require pole ground based on application crossarm available AmerenMO only. 7. Deadend on pole w/o fiberglass extension available AmerenMO only. 8. See DCS ** for neutral configuration. ENG: MJ REV. NO: 9 REV. DATE: 2/17/12
14 CONFIGURATIONS Two or Three Phase Loopovers 4 to 15kV ** Sheet 2 of 5 Dist. Std. Or Stk. No. Description ** A Deadend Assy. FG, Deadend Assy. FG, C Loopover w/fg Extension, Pole Top Loopover w/o FG Extension, Pole Top 1 1 D Loopover, Sgl Arm F DEC*W Clamp, Deadend G TT*W Top Tie, Sgl Pin I Grounding Unit, Wood Pole Grounding Unit, Composite Pole J PG* See Std @ K Neutral, Thru P PLW*W Lead Wire, Poly covered, Ft or 260 Install jumper ENG: MJ REV. NO: 9 REV. DATE: 2/17/12
15 CONFIGURATIONS Two or Three Phase Loopovers 4 to 15kV ** Sheet 3 of 5 P P J P P G G 8 8 C E C E W/EXTENSION W/O EXTENSION Pole Top w/o Extension Pole Top w/extension Underbuild Dist. Std. Or Stk. No. Description ** C Pole Top Loopover w/extension Pole Top Loopover w/o Extension 1 1 E Looparound, Pole F DEC*W Clamp, Deadend G TT*W Top Tie, Sgl Pin J PG* See Std P PLW*W Lead Wire, Poly covered, Ft or 260 Install jumper ENG: MJ REV. NO: 9 REV. DATE: 2/17/12
16 CONFIGURATIONS Two or Three Phase Loopovers 4 to 15kV ** Sheet 4 of 5 P J C L J 1 D G D 2 K DE Assy. 10 Arm UNDERBUILD F/G ARM 8 Arm SIDEARM NOTES: 1. Wildlife cover required for AmerenIL only. ENG: MJ REV. NO: 9 REV. DATE: 2/17/12
17 CONFIGURATIONS Two or Three Phase Loopovers 4 to 15kV ** Sheet 5 of 5 Dist. Std. Or Stk. No. Description ** C Pole Top Loopover 1 1 D Loopover Arm E Looparound F DEC*W Deadend Clamp G TT*W Top Tie I Crossarm, DE Assy., 10 1 J PG* See Std P PLW*W Lead Wire, Poly covered, Ft K Sidearm, Double, @ L Wildlife Cover DE 252 or 260 Install jumper ENG: MJ REV. NO: 9 REV. DATE: 2/17/12
18 CONFIGURATIONS ** Single Circuit 34kV or 69kV Tangent Structure for Line Angle < 1 o Sheet 1 of 3 AA SHIELDED 6 1 MIN. A AA 180º 135º 225º 90º 270º 45º 315º 0º WOOD FACE OF POLE SHIELDED 6 MIN. 1 RAKE 1 0 A BB BB MIN. MIN. B or C 4 F KV INS KV INS. BB 0 SECTION AA AA º BB MIN. MIN. CL E 10 34KV INS KV INS MIN. 0 º SECTION BB BB MIN. 1 F 3 B or C IL & MO 69 KV IL & MO 69 KV MO 34 KV MO 34 KV Stnd./Stk. No. Description ** A Static Support w/susp. Clamp B Insul., 34kV, Horz., Sgl Post w/clamp Top 3 C Insul., 69kV, Horz., Sgl Post w/clamp Top Insul., 69kV, Horz., Sgl Post w/susp. Clamp 3 E TC*W Clamp, Top, Tang/Ang, Cond SC*W Clamp, Susp, Tang/Ang, Cond. 3 F Grounding, Wood Pole Grounding, Composite Pole ENG: KR REV. NO: 3 REV. DATE: 01/22/2016
19 CONFIGURATIONS ** Single Circuit 34kV or 69kV Tangent Structure for Line Angle < 1 o Sheet 2 of 3 6 AA MIN. 6 MIN. BB 7 6 MIN. B 1 A AA C E 1 180º 135º 225º 90º 45º 0º 270º 315º WOOD FACE OF POLE BB SECTION AA AA 0 º AA 6 MIN. D MIN. BB MIN. A 1 4 AA 1 0 BB C E 1 Ë ËËË Ë ËË MIN. 0º 03 SECTION BB BB 04 Stnd./Stk. No. Description ** A Static Support w/susp. Clamp 1 B Insul., 69 kv, Horz. Sgl Post w/clamp Top Insul., 69 kv, Horz., Sgl Post w/susp. Clamp C Insul., 69 kv, Horz., Dbl Post w/clamp Top Insul., 69 kv, Horz., Dbl Post w/susp. Clamp 1 D TC*W Clamp, Top, Tang/Ang, Cond. 1 3 SC*W Clamp, Susp., Tang/Ang, Cond. 1 E Grounding, Wood Pole Grounding, Composite Pole 1 F Insul, 138 kv, Horz.,Dbl Post w/susp. Clamp ENG: KR REV. NO: 3 REV. DATE: 01/22/2016
20 CONFIGURATIONS ** Single Circuit 34kV or 69kV Tangent Structure for Line Angle < 1 o Sheet 3 of 3 NOTES: 1. Install pole ground on wood pole as shown on configuration. Composite pole is pre assembled with #2 Str. Cu. Pole ground at 45 degree quadrant. See DCS or for grounding detail. 2. A taller pole shall be selected to replace existing 4 spacing and also to provide adequate ground clearance. If taller pole does not provide adequate ground clearances, consider utilizing Standard This standard is to be used where a future second circuit is anticipated or where constrained by horizontal clearance requirements or right of way issues. 4. Modify configuration 01 to 03 for additional clearance or use 138kV insulator to maintain additional horizontal separation if galloping is a concern. 5. If future circuits are anticipated reposition back to back insulator arrangement to upper position to 03 if strength requirements and shielding angle are met. 6. Use 7 6 spacing for tangent structure and 7 0 spacing for deadend structure. (use top bolt of fiberglass arm) 7. Install ground clamp above grade on wood and below grade on composite pole. See DCS **. 8. Use composite pole for storm structure as existing maintenance replacement or new line installation. See DCS for storm pole selection. ENG: KR REV. NO: 3 REV. DATE: 01/22/2016
21 CONFIGURATIONS ** 34kV or 69kV Tangent Structure for Line Angle <1 o Sheet 1 of 2 LIMITED USE STANDARD 6 2 B BB 0 12 BB D,F BB D,F BB 0 12 Ë Ë 7 6 MIN. 3 Ë ËËË Ë SECTION BB BB 7 6 MIN. 3 ËË Ë 69 KV KV KV Stnd./Stk. No. Description ** B Ins., 34 kv, Vert. Tie Top F Neck w/tie Ins., 69 kv, Vert. Tie Top N Neck w/tie D Insul., 69 kv, Horz., Dbl Post w/clamp Top Insul., 69 kv, Horz., Dbl Post w/susp. Clamp 1 3 F TC*W Clamp, Top, Tang/Ang, Cond SC*W Clamp, Susp., Tang/Ang, Cond. 2 6 G Grounding, Wood Pole Grounding, Composite Pole 1 1 H ** Arrester Assy. 1 1 L Insul, 138 kv, Horz., Dbl Post w/susp. Clamp ENG: KR REV. NO: 5 REV. DATE: 01/14/2016
22 CONFIGURATIONS ** 34kV or 69kV Tangent Structure for Line Angle <1 o Sheet 2 of 2 NOTES: 1. A taller pole should be selected to replace existing 4 phase spacing and also to provide adequate ground clearance. 2. See Dist. Std for lighting arresters application and construction. 3. Use 7 6 distance to tangent and 7 0 to deadend crossarm (top bolt on FG arm) hole. 4. Use 138kV insulator to maintain horizontal separation if galloping is a concern. ENG: KR REV. NO: 5 REV. DATE: 01/14/2016
23 WILDLIFE PROTECTION 25kV & Below Cutout Cover Sheet 1 of 1 The cutout live parts cover shown in this standard shall be used on the Ameren Distribution System to prevent circuit outage from wildlife contact. The cover is not intended for personal protection. CAUTION: AT TEMPERTURES BELOW 0 O F THE CUTOUT COVERS BECOME RIGID AND LOSE THEIR FLEXIB- ILITY. INSTALLING THE COVERS WITH A HOTSTICK MAY CAUSE THE COVERS TO BREAK. NOTES: 1. Can be installed with live line tools. 2. Refer to Dist. Std ** for cutout installation. 3. The cover is intended for wildlife outage only. 4. Install the cutout cover from the front side. Push the cutout cover around the conductors. Pull the cover down until the interior fingers fully engage the sleet hood. Stnd. / Stk. No. Description ** 01 A Cover, Cutout 1 B 111 Cutout cover Installation 1 ENG:JWC REV. NO: 1 REV. DATE: 10/21/15
24 WILDLIFE PROTECTION 25kV & Below Conductor Cover Single Pin ** Sheet 1 of 1 The conductor and insulator cover shown in this standard shall be used on Ameren Distribution System to prevent avian outage from distribution facilities where horizontal conductor spacing is less than five feet. The cover is not intended for personal protection. B A 01 NOTES: 1. The cover is intended for wildlife outage only. 2. The cover can be installed with live line tools. 3. Cover fits #6 to 556 conductor on 55 5 pin, and 56 1 pin. 4. Install two covers on two interior positions when existing arm has four conductor configuration. 4 Stnd. / Stk. No. Description ** A Cover, Single Pin Configuration 1 2 B Cover, Extension Arm 2 4 C 111 Wildlife cover Installation 1 2 ENG: MJ REV. NO: 1 REV. DATE: 09/29/11
25 WILDLIFE PROTECTION 25kV & Below Conductor Cover Double Pin ** Sheet 1 of 1 The wire and insulator cover shown in this standard shall be used on Ameren Distribution System to prevent avian outage from distribution facilities where horizontal conductor spacing is less than five feet. The cover is not intended for personal protection. B A 01 NOTES: 1. The cover is intended for wildlife outage only. 2. The cover can be installed with live line tools. 3. Install two covers on two interior position when existing arm has four conductor configuration. 3 Stnd. / Stk. No. Description ** A Cover, Double pin configuration 1 2 B Cover, Extension arm 1 4 C 111 Wildlife Cover Installation 1 2 ENG: MJ REV. NO: 1 REV. DATE: 09/29/11
26 WILDLIFE PROTECTION 25kV & Below Deadend Cover ** Sheet 1 of 1 The conductor and insulator covers shown in this standard shall be used on the Ameren Distribution System to prevent wildlife outages on distribution facilities where horizontal conductor spacing is less than five feet. The cover is not intended for personal protection. C B A The cover is intended for wildlife protection only. 2. Item A can be installed using live line tools if required. 3. If configuration has four cross arms, use standard Item B is required if the jumper is bare conductor. Stnd. / Stk. No. Description ** A Cover, DE 2 4 4@ B Cover, Loopover, up to 0.5 Cond. Diameter Cover, Loopover, 0.5 to Cond. Diameter C Tape, Insulating 1 1 D 111 Wildlife cover Installation 1 2 ENG: JC REV. NO: 2 REV. DATE: 03/07/17
27 INSULATORS AND SUPPORTS Pin and Insulator 12kVandStatic ** Sheet1of1 A A A F C K F F F SglPinandInsulator -- WoodArm H G,H,K DblPinandInsulator -- FGArm K H Sgl Pin and Insulator--FG Arm A A A B B 8 8 D,E,H D,E 8 8 D,E,H D,E E SglPoleTopPin&Ins. E DblPoleTopPin&Ins. Notes: 1. The2 washerreceivedwiththepinshouldbeusedafterthewashertoeliminatethecoilwasherfromsliding inside the washer. XA Pole Top Stnd./ Stk. No. Description ** A Insulator, Pin Type B Pin,PoleTop,2 1 2 C Plate, Dbl Pin 1 D Bolt,Mach.,5/8 x E Washer, Curved, 3/ 4 2 F Pin, Insulator, Long Shank Pin, Insulator, Short Shank 2 G Bolt,Mach.,5/8 x6 1 H Washer, Lock, Galvanized, 5/8 dbl coil type K Washer,Flat,Sq.,x,w13/16 hole 1 2 ENG: KP REV.NO:12 REV. DATE: 9/11/2017
28 INSULATORS AND SUPPORTS Deadends on Pole 12 kv ** Sheet 1 of 2 D M C D C F,G F,G W/FG EXTENSION J WO/FG EXTENSION J STRAIGHT DEADEND D C F,G H FLOATING ANGLE K C M E D M F,G J DOUBLE DEADEND W/FG EXTENSIONS J E D C F,G J DOUBLE DEADEND WO/FG EXTENSIONS J ENG: WYW REV. NO: 7 REV. DATE: 09/04/14
29 INSULATORS AND SUPPORTS Deadends on Pole 12 kv ** Sheet 2 of 2 B A M E 8 D 8 M C F,G J W/FG Extension J A B E 8 D 8 C F,G J WO/FG Extension POLE TOP LOOPOVER J Stnd. / Stk. No. Description ** A Pin, Pole Top 1 1 B Ins., Pin Type 1 1 C Ins., Suspension, 15 kv D Eyelet, 3/ E Eyenut, 3/ F Bolt, Mach., 3/ x G Washer, Square, ¾ H Shackle, Deadend J DEC*W Conductor Deadend clamp K SC*W Suspension Clamp 1 M Insulator, Guy Strain, F/G, 26, 15k UTS N Nut, Lock, Square, Galv, ¾ ENG: WYW REV. NO: 7 REV. DATE: 09/04/14
30 INSULATORS AND SUPPORTS Horizontal Post Insulators 69 kv ** Sheet 1 of 2 K,H,G,F C A E 2500 lbs. 5 o 10 or 12 C 1,250 lbs. working load K,H,G,F POLYMER INSULATOR W/TRUNNION CLAMP SINGLE DOUBLE K,H,G F K,H,G B 5,000 lbs. 10 or 12 D L M D 1,250 lbs. working load K,H,G K,H,G POLYMER INSULATORS W/SUPENSION CLAMP SINGLE DOUBLE NOTES: 1. Reverse bolt position if guy wire is attached to bottom bolt. 2. Longer bolts are for use on larger diameter poles. ENG: MJ REV. NO. 4 REV. DATE: 09/10/13
31 INSULATORS AND SUPPORTS Horizontal Post Insulators 69 kv ** Sheet 2 of 2 Stnd. / Stk. No. Description ** A Insulator, Horiz. Post, 69 kv, Polymer, Trunnion Clamp 1 2 B Insulator, Horiz. Post, 69 kv, Polymer, Suspension Clamp 1 C Bolt, Mach., 3/ x Bolt, Mach., 3/ x 16 2 D Bolt, DA, 3/ x Bolt, DA, 3/ x 18 2 E TC*W Clamp, Trunnion 1 2 F Washer, Square, for 3/ Bolt, 3 x3, Galvanized 2 2 G Washer, Lock, 3/ Dbl Coil Type H Nut, Square, 3/ x 10 TPI, Galvavized * * * * K Nut, Locking, 3/, Galvanized L Wye Clevis Eye, 11/16 hole, 5/8 Thick, 3/ Pin Dia. 1 M SC*W Clamp, Suspension 1 2 * Furnished with DA bolts (4) or machine bolts (1). ENG: MJ REV. NO. 4 REV. DATE: 09/10/13
32 FUSES AND SWITCHES Single Phase Sectionalizing All Construction Amp 4 or 12 kv ** Sheet 1 of AMP FUSED 200 AMP FUSED 300 AMP SOLID BLADE K M 2 C,D N L F F 8 12 A,P B 40 to 72 J NOTES: 1. Use DCS for ground coil application on new pole installation. 2. Double deadend on pole w/o FG extension available AmerenMO only. ENG: WYW REV. NO: 10 REV. DATE: 06/29/16
33 FUSES AND SWITCHES Single Phase Sectionalizing All Construction Amp 4 or 12 kv ** Sheet 2 of 2 Stnd. / Stk. No. Description ** A Switch, Fuse, 100A, 15kV Switch, Fuse, 200A, 15kV Switch, Solid Blade, 300A, 15kV 1 B Bracket, Fiberglass, Switch and Arrester C Bolt, Mach., 5/8 x D Washer, Square, 5/8 2 2 F PLW*P Wire, CU, Poly, SD, (ft.), DCS @ J Grounding Unit Ground Rod Grounding Unit Ground Coil 1 1 K PG* Clamp, Parallel Groove, DCS @ M Dbl Deadend on Pole w/ FG Extension Dbl Deadend on Pole w/o FG Extension 1 1 N DEC*W or DEA*W Clamp, Deadend, DCS O Link, Fuse ( Sized by Engineer ) P Cover, Cutout ENG: WYW REV. NO: 10 REV. DATE: 06/29/16
34 FUSES AND SWITCHES Three Phase Sectionalizing Amp 4 or 12 kv ** Sheet 1 of 2 MISSOURI ONLY ÄÄ ÄÄ 100 AMP. FUSED 200 AMP. FUSED 300AMP. SOLID BLADE TURN SWITCHES TOWARD POLE A, P, O E 4 H K SOURCE LOAD F D 3 C A,N I L M MIN. D Q O B M G 2 ENG: WYW REV. NO: 6 REV. DATE: 06/30/16
35 FUSES AND SWITCHES Three Phase Sectionalizing Amp 4 or 12 kv ** Sheet 2 of 2 NOTES: 1. This installation is permissible for existing installation in Missouri. For new installations, arresters are not required for normally closed switch installations. Where switches are normally open, install arresters on adjacent poles. Refer to DCS for arresters selection. 2. Use DCS for ground coil application on new pole installation. 3. Double deadend on pole w/o FG extension available AmerenMO only. 4. Underbuild construction requires deadend on pole w/fg extension. Stnd. / Stk. No. Description ** A Switch, Fuse, 100A., 15kV Switch, Fuse, 200A., 15kV Switch, Solid Blade, 300A., 15kV 3 1@ B Arrester, 10kV w/protective Cap Arrester, 3kV w/protective Cap 3 3 C Crossarm, Deadend, FG, Crossarm, Deadend, FG, D Crossarm, Sgl, Wood, 10 (use only 1/2 of V Brace) Crossarm, Sgl, Wood, 8 (use only 1/2 of V Brace) @ E Dbl Deadend on Pole w/ FG Extension Dbl Deadend on Pole w/o FG Extension F Double Deadend on Arm G Grounding Unit Ground Rod 1 1 H DEC*W or DEA*W Clamp, Deadend 6 6 I PLW*W Wire, Poly covered, S.D. (ft.) J PG* Clamp, Parallel Groove ( See Std ) HLC*W Clamp, Hot Line 3 3 K PG* Clamp, Parallel Groove (See Std L Clamp, Hot Line M Wire, Poly Covered, #6 Cu., (Ft.) N Link, Fuse ( Sized by Designer ) 3 3 O Bracket, Mounting Switch, Arrester P Cover Cutout Q Connector, Split Bolt ENG: WYW REV. NO: 6 REV. DATE: 06/30/16
36 FUSES AND SWITCHES Three Phase Sectionalizing Crossarm Pole Top Construction 600 Amp 4 or 12 kv ** Sheet 1 of 3 MISSOURI ONLY ALTERNATIVE K F N K C A E J J C 6 G ENG: WYW REV. NO: 8 REV. DATE: 06/30/16
37 FUSES AND SWITCHES Three Phase Sectionalizing Crossarm Pole Top Construction 600 Amp 4 or 12 kv ** Sheet 2 of 3 ALTERNATIVE MISSOURI ONLY K F N K C G A E J J L M D C 6 D 6 D B 1 M 2 0 MIN G ENG: WYW REV. NO: 8 REV. DATE: 06/30/16
38 FUSES AND SWITCHES Three Phase Sectionalizing Crossarm Pole Top Construction 600 Amp 4 or 12 kv ** Sheet 3 of 3 NOTES: 1. Alternative 2 is permissible for existing installation in Missouri. For new installation, both Illinois and Missouri, arresters are not required for normally closed switch installations; where switches are normally open, install both sets of arresters on adjacent poles. Refer to DCS for arresters selection. 2. If insulators are not at least 2 from switch base using a single eye clevis, install one additional eye clevis in each deadend. On angle poles, a shackle may also be necessary to obtain clearances. 3. When required, switch number tag shall be installed here crossarm available AmerenMO only. 5. Double deadend on pole w/o FG extension available Missouri only. Stnd. / Stk. No. Description ** A Switch, Dis., 600A, 15kV 3 3 1@ B Arrester, 10kV Arrester, 3kV 3 4@ C Crossarm, Dbl, Wood 10 ( use only 1/2 of V brace ) Crossarm, Dbl, Wood 8 ( use only 1/2 of V brace ) 1 1 4@ D Crossarm, Sgl, Wood 10 ( use only 1/2 of V brace ) Crossarm, Sgl, Wood 8 ( use only 1/2 of V brace ) 1 2 E Double Deadend on Arm 2 F DEC*W Clamp, Deadend, DCS G Grounding Unit on Existing Pole Ground Rod Grounding Unit on New Pole Ground Coil 1 J PLW*W Wire, Poly covered, (ft.), DCS K PG* Clamp, Parallel Groove, DCS L Clamp, Hot Line 3 M Wire, Poly, #6 Cu., Ft. 15 5@ N Dbl Deadend on Pole w/ FG Extension Dbl Deadend on Pole w/o FG Extension 1 1 ENG: WYW REV. NO: 8 REV. DATE: 06/30/16
39 FUSES AND SWITCHES Single Phase Tap From Single Phase All Construction Amp. 4 or 12 kv ** Sheet 1 of 1 E H G H 100 AMP. FUSED 200 AMP. FUSED 300 AMP. SOLID BLADE G F O C,D B G A N M 40 to 72 F K Stnd. / Stk. No. Description ** A Switch, Fuse, 100A, 15 kv Switch, Fuse, 200A, 15kV Switch, Solid Blade, 300A, 15kV 1 B Bracket, Switch, Arr. and Deadend C Bolt, Mach., 5/8 x D Washer, Square, 5/ E Ins., Suspension, 12kV 1 1 F DEC*W or DEA*W Clamp, Deadend 1 1 G PLW*W Wire, Poly Covered (ft.), DCS H PG* Clamp, Parallel Groove DCS K Grounding Unit New Pole Ground Coil Grounding Unit Existing Pole Ground Rod 1 1 N Link, Fuse (Sized by Engineer) 1 1 O Cutout Cover ENG: WYW REV. NO: 12 REV. DATE: 12/15/15
40 FUSES AND SWITCHES Single Phase Tap From Three Phase All Construction Amp. 4 & 12kV ** Sheet 1 of Amp Fused Amp Fused Amp Solid Blade H H H 2 P R H M,Q H ENG: WYW REV. NO: 11 REV. DATE: 03/21/17
41 FUSES AND SWITCHES Single Phase Tap From Three Phase All Construction Amp. 4 & 12kV ** Sheet 2 of 2 Std. /Stk. No. Description ** A Switch, Fuse, 100A, 15 KV Switch, Fuse, 200A, 15 KV Switch, Solid Blade, 300A, 15 KV 1 B Bracket NEMA, Switch and Dead End C Bolt, Mach., ⅝ x D Washer, Square, ⅝ E Ins., Suspension, 15 KV 1 1 F DEC*W Clamp, Deadend DCS G PLW*W Wire, Poly Covered (ft.) DCS & H PG* Clamp, Parallel Groove or Split Bolt or Two Bolt. See I Shackle, Deadend @ K Grounding Unit New Pole Ground Coil Grounding Unit Existing Pole Ground Rod M Washer, SQ, ¾ N Link, Fused, (sized by Engineer) O Cover, Cutout P Eyelet, ¾ 1 1 R SDEA*W Deadend, Automatic, Secondary. See Q Bolt, Machine ¾ x @ S ** ** Guy Unit NOTES: 1. Use DCS for ground coil application on new pole installation. 2. This distance may be reduced to 40 inches if approved by engineering. Center the guy attachment between the primary and neutral if this distance is reduced. ENG: WYW REV. NO: 11 REV. DATE: 03/21/17
42 FUSES AND SWITCHES Two or Three Phase Tap Crossarm Construction Amp 4 or 12kV ** Sheet 1 of 2 K K Near Phase Far Phase J F C 4 0 R C D TURN SWITCHES TOWARD POLE A,P,B I H 2 PHASE 3 PHASE 100 AMP FUSED AMP FUSED AMP SOL. BL ENG: WYW REV. NO: 11 REV. DATE: 06/01/17
43 FUSES AND SWITCHES Two or Three Phase Tap Crossarm Construction Amp 4 or 12kV ** Sheet 2 of 2 Notes: 1. Use DCS for ground coil application on new pole installation crossarm available AmerenMO only. Stnd / Stk. Description ** 2 PHASE 3 PHASE A Switch, Fused, 100A, 15 kv Switch, Fused, 200A, 15 kv Switch, Solid Blade, 300A, 15 kv 2 3 B Bracket NEMA, Switch @ C Crossarm, Deadend, F/G, Crossarm, Deadend, F/G, D Deadend on Pole w/fg Extension E Deadend on Single Arm F Insulator and X Arm Pin G DEC*W or DEA*W Clamp, Deadend @ H Grounding Unit Existing Pole Ground Rod Grounding Unit New Pole Ground Coil I Neutral Deadend J PLW*W Wire, Poly covered, S.D.(ft.) DCS K PG* Clamp, Parallel Groove DCS P Link, Fused (Sized By Designer) R Cover Cutout ENG: WYW REV. NO: 11 REV. DATE: 06/01/17
44 ING Insulator Dimensional Requirements Sheet 1 of 8 Single Phase 4 to 15kV ËËË Ë COMM. 45 COMM Loopover Tap COMM. 45 COMM Pole Top Pin Floating Angle ENG: DDG REV. NO: 2 REV. DATE: 03/01/2016
45 ING Insulator Dimensional Requirements Sheet 2 of 8 8 Single Phase 4 to 15kV COMM. 45 COMM Degree Angle Deadend One, Two or Three Phase Angle on Wood Crossarm 4 to 15kV COMM. COMM. 45 TANGENT 30/ 20/ Preferred Avian Angle 10 Sgle. Arm Angle 8 Sgle. Arm UNDERBUILD 30 / 20 / 10/ Angle 8 Sgle. Arm Angle 8 Dble. Arm Angle 10 Sgle. Arm Angle 10 Dble. Arm ENG: DDG REV. NO: 2 REV. DATE: 03/01/2016
46 ING Insulator Dimensional Requirements Sheet 3 of 8 One, Two or Three Phase Angle on Wood Crossarm 4 to 15kV COMM. Deadend Arm Pole Top or Underbuild SIDEARM 66 30/ 20/ Tangent 8 Sgle. Arm Angle 8 Sgle. Arm Angle 8 Dble. Arm COMM. 30 / 20 / 10/ DE Assy 8 Arm DE Assy 10 Arm ENG: DDG REV. NO: 2 REV. DATE: 03/01/2016
47 ING Insulator Dimensional Requirements Sheet 4 of 8 Two or Three Phase Floating and 90 Angle 4 to 15kV COMM VERTICAL FLOATING ANGLE / / COMM VERTICAL 90 DEGREE ANGLE With FG Ext. W/o FG Ext. 30 / / : ENG: DDG REV. NO: 2 REV. DATE: 03/01/2016
48 ING Insulator Dimensional Requirements Sheet 5 of 8 Two or Three Phase Buck Arm 90 Angle 4 to 15kV o COMM / 30 / 20/ W/Ext. W/o Ext. (NOT SHOWN) 8 F.G. ARMS F.G. ARMS ENG: DDG REV. NO: 2 REV. DATE: 03/01/2016
49 ING Insulator Dimensional Requirements Sheet 6 of 8 Two or Three Phase Vertical Tap 4 to 12 kv COMM ENG: DDG REV. NO: 2 REV. DATE: 03/01/2016
50 ING Insulator Dimensional Requirements Sheet 7 of 8 3 to 100kVA Deadend or L Corner ÈÍ Ë ÈÍ Ê On L corners, where a guy can only be installed below the transformer, a Class 4 or heavier pole shall be used. A class 4 pole will provide adequate strength for deadending 1 1/0 bare AAAC at 1,360 lbs. Max. Tension (non standard intermediate span urban construction). For conductor tension greater than this, contact Distribution Standards for determination of pole class ENG: DDG REV. NO: 2 REV. DATE: 03/01/2016
51 ING Insulator Dimensional Requirements Sheet 8 of 8 Transformer, 1PH, T Corner ENG: DDG REV. NO: 2 REV. DATE: 03/01/2016 :
52 LIGHTNING PROTECTION AND GROUNDING Grounds ** Sheet1of5 Connectors positioned above ground with a staple above and below the connector I BELOW GRADE - NEW CONSTRUCTION 1 EXCAVATED EARTH 6 EXISTING Connectors positioned above ground with a staple above and below the connector I K 6 SOIL ROCK APPROX.1-0 Connectors positioned above ground with a staple above and below the connector I 6 1 EXCAVATED EARTH AA AA APPROX. 6 AUGER SIZE 6 1 EXCAVATED EARTH EXISTING SOIL ROCK BACKFILL EXISTING SOIL K EARTH AUGER SIZE K FOAM AA AUGER SIZE AA APPROX. 6 EXCAVATED EARTH BACKFILL AA AA APPROX. * * 6 AUGER SIZE **12-0 MIN.COIL SECTION AA-AA #10 CW Pole Ground/Ground Coil 15kV&Below #2CuPoleGround/GroundCoil15kV&Below #10CWPoleGround/GroundCoil34&69kV CompositePole12kV CompositePole34&69kV FOAM BACKFILL NOTES: 1. Trainbelowgradegroundwireapproximately8 abovegroundlinetolineupwithpolegroundwireabovegrade. Avoid making sharp bends. 2. See DCS 02 for pole setting depth, reinforcement, and backfill detail. ENG:JMW REV.NO:20 REV. DATE: 09/20/17
53 LIGHTNING PROTECTION AND GROUNDING Grounds ** Sheet2of5 BELOW GRADE - EXISTING CONSTRUCTION Non-Tension Sleeve Reducer - connect pole ground wirewith#2solidcubareto7#10cwandposition above ground against pole with a staple above and below the connector I K F E 1 6 Min. 6 Min #10CWPoleGround/GroundRod12kV&Below #10CWPoleGround/GroundRod34&69kV #2CuPoleGround/GroundRod NOTES: 1. Groundresistancewillnormallybelessthan25ohmswithonecoiloronerod. Inrockyorsandysoilwhereexperience indicates ground resistance may exceed 25 ohms, install additional coil or rods spaced not less than 6 apart. Doublingthenumberofrodsorcoilsordoublingthelengthoftherodreducesgroundresistanceby40%. If additional grounding is needed: a) terminalpoles -- a#2barecucounterpoisewire longmaybeplacedinthecabletrenchand connected to the ground lead. b) inrockysoilwheredrivingarodisdifficult -- acounterpoise,asstatedina),maybeplacedinatrenchatleast 18 deep. ENG:JMW REV.NO:20 REV. DATE: 09/20/17
54 LIGHTNING PROTECTION AND GROUNDING Grounds ** Sheet3of5 ABOVEGRADE - WOODPOLE 5 A NEUTRAL G G 7 B APPROX B 4 C kV &04 -Newinstallation &03 - Existing Pole Installation AddStaples AddGroundMolding/Staples 34kV&69kV New-7#10CW Pole Ground/Field Formed Coil-34&69kV Existing-7#10CW Pole Ground/Ground Rod 34&69kV Replacement-Add Staples NOTES: 1. Thegroundwireshallberuninasstraightalinedownthepolewithoutmakingsharpbendsinsuchamanneras to clear hardware by at least 2 inches. Avoid damaging ground wire when installing staples. 2. According to an NESC subcommittee s interpretation, metal brackets and straps used to support non--conductive conduits do not need to be grounded. However, conductive material conduits that enclose electrical supply lines or are exposed to contact with open supply conductors must be effectively grounded. 3. Refer to DCS Section 03 for proper grounding position on different structure configuration. 4. Staplesaretobespaced3 onpolegroundwireand1 --6 fromtopofthepoleon34kvand69kvline. 5. SeeDCS060011**forstaticsupportassemblyandDCS123401**and123402**forlightningarresterconnection. 6. Reconnectexistinggroundwirewith7#10CWifpolegroundwireismissingusingDCS Installplasticmoldingonanexistingbarewirepolegroundwhenre--framinganexistingpoleusingDCS ENG:JMW REV.NO:20 REV. DATE: 09/20/17
55 LIGHTNING PROTECTION AND GROUNDING Grounds ** Sheet4of5 ABOVE GRADE- COMPOSITE POLE A G G 6 NEUTRAL kV CompositePole 34kV&69kV CompositePole Notes: 1. Factory installed#2 Cu pole ground. ENG:JMW REV.NO:20 REV. DATE: 09/20/17
56 LIGHTNING PROTECTION AND GROUNDING Grounds ** Sheet5of5 Stnd./Stk. No Description ** A Wire, 7#10, CW Poly Covered(ft.) @ Wire,#2Cu.Polycovered (ft.) B Molding -- Grd.Wire,3/x8 Long 1 C Staple,GroundWire,Serrated,CuClad D Staple, for 3/ Plastic Molding, Zn Plated Stl E Rod,Ground,5/8 x8 CuBond F Clamp,Grd.Rod,5/8 for#8 -- 1/ G Clamp, PG.#6 -- 1/ I Non--Tension Sleeve Reducer, Compression -- #2Cu,Solto7#10CWor#2Cu,Str K Wire,#2BareCu,Sol(ft.) @ L Non--Tension Sleeve, Compression, 7#10 CW OP 301 Install Below Grade Ground Coil OP 302 Install Above Grade Pole Ground OP 401 Install Pole Ground/Ground Rod Note: 1. Use the appropriate connector for the ground wire size being replaced. Non--tension sleeve stock# can beusedfor7#10cwconnections,reducingnon--tensionsleevestock# canbeusedfor#2solidcuto 7#10CWor#2strandedCuconnections,andsplit--boltstock# canbeusedformostotherconnections. 2. When an underbuild circuit is added, the conductor from the static neutral to the distribution neutral and ground mustbe#2cupolyorlarger. ENG:JMW REV.NO:20 REV. DATE: 09/20/17
57 TRANSFORMERS 15 kv and Below Grounded Wye Primary System KVA Single Phase Protected Sheet 1 of 3 FOR CSP TRANSFORMER INSTALLATION SEE NOTE 7 FOR TRANSFORMER WITHOUT TANK MOUNTED ARRESTER SEE NOTE B TURN SWITCH TOWARD POLE. K N, D J SEE ARRESTER MOUNTING DETAIL 9 8 S 30 5 A A PRIMARY NEUTRAL H 1 L,M F T C,D 12 50kVA & Smaller or kVA SEE DCS FOR 120/240 OR 240/480 V 3 WIRE SEE DCS FOR 120 OR 240 VOLT 2 WIRE G A 6 10 NOTE: TRANSFORMERS MAY BE RECEIVED WITH THE LA MOUNTED BESIDE EITHER THE H1 OR H2 BUSHING. BOTH POSITIONS ARE ACCEPTABLE. POSITION THE SWITCH FOR EASY CONNECTION TO THE BUSHING HAVING THE LA ATTACHED. 13 R #2 Cu H.D. FOR LA CONNECTION S 16 P Q TO LINE R 16 S MAY BE ROTATED FOR SECONDARY CLEARANCE SECTION AA WITH CUTOUT COVER SWITCH DETAIL 8 O SEE SWITCH DETAIL TO GROUND TO TRANSFORMER ARRESTER MOUNTING DETAIL FOR TRANSFORMER WITHOUT TANK MOUNTED ARRESTER ENG: DG REV. NO: 12 REV. DATE: 11/17/15
58 TRANSFORMERS 15 kv and Below Grounded Wye Primary System KVA Single Phase Protected Sheet 2 of 3 Stnd. / Stk. No. Description A ** Grounding Unit B HLC*W Hot Line Clamp 1 T C Bolt, Mach., 5/8 x 12 (50 kva & smaller) OR Bolt, Mach., 3/ x 12 ( kva) 2 T D Washer, Square, 5/8 (50 kva & smaller) OR Washer, Curved, 3/ ( kva) 2 T F Secondary Leads (Ft.) (See ) 12 T G PG* See H Transformer (see ) 1 T9 J Wire, Trans. Riser, #4, S.D. Poly covered (FT.) 12 K Bracket, Cutout 1 5, 7 L Switch, Fused, Open Type M Link, Fuse 1 N Bolt,, Mach, 5/8 x 12 O Bracket, 3 Position, Equipment Mount P Arrester, Lightning (see ) Q Wire, #6Cu, S.D. R Clamp, Hotline, #6 to 2/0 1 NOTES: S Cover Cutout 1 T T Wire, #4 Cu, S.D., Covered Arrester may be shifted to most convenient side of tank on two bushing transformers. 2. Deadend construction Deadend primary one span past transformer pole if there is another pole in the lead. If not, see DCS Measure distance between mounting slots and drill so that transformer rests evenly on both bolts. 4. See DCS for fuse selections. 5. Switch may be mounted on either side of pole or on the crossarm. If the switch is mounted on the crossarm, it should be positioned 12 from the pin insulator or from the pole. The transformer may be raised 12 to 2 when the switch is located on the crossarm. Omit items K and N. 6. See DCS ** for secondary support and DCS ** for secondary configurations. 7. If installing a CSP transformer, a fused switch shall be installed as shown. Exception: If existing pole space does not allow for installation of a fused switch and the number of customers affected by transformer failure is deemed acceptable, then items K, L, M, N, and S may be omitted and connect the transformer primary lead to the overhead conductor. 8. If installing a transformer that does not have a tank mounted lightning arrester use items O, P, Q, and R and install the appropriate lightning arrester on the bracket beside the switch. Keep arrester leads as short as possible. See note 16 for avian protection requirements /4160Y transformer may have side wall or cover mounted HV bushings. If side wall mounted bushings: a. Build according to this DCS except use 2.5kV primary lead wire stock # , or b. If pole is congested, 2.5kV primary lead wire stock # in conduit similar to DCS may be used. 10. Use DCS for ground coil application on new pole installation. Use DCS for ground rod application on existing pole installation. ENG: DG REV. NO: 12 REV. DATE: 11/17/15
59 TRANSFORMERS 15 kv and Below Grounded Wye Primary System KVA Single Phase Protected Sheet 3 of This dimension is to top bolt position if FG crossarm is used. 12. Use DCS for existing structure modification or DCS for pin cover in area with eagle population. 13. If pole is NOT truck accessible, make secondary connections on the climbing side of the pole. 14. Use DCS ** for new pole installation. 15. On single phase pole lines where future addition of crossarm for adding additional phases is not reasonably expected, this dimension can be reduced to 6 (i.e., total of 36 from the pole top to the top bolt of the cutout bracket). 16. For all of Illinois and locations in Missouri where additional avian protection is needed, omit the piece of #2 copper wire and hotline clamp R. Connect the #6 copper poly covered arrester wire Q directly to the fused switch connector. ENG: DG REV. NO: 12 REV. DATE: 11/17/15
60 TRANSFORMERS Three Single Phase Cluster Mounted 15 kv and Below Grounded Wye Primary Systems ** Sheet 1 of 2 GROUNDED WYE PRIMARY CONNECTION TO FUSED CUTOUTS AND COMMON NEUTRAL R,S HIGH VOLTAGE NEUTRAL CONNECT TO SYSTEM NEUTRAL TO LINE E TO TRANSFORMER #2 Cu H.D. FOR LA CONNECTION P 8 SWITCH DETAIL TO GROUND 9 Q TO LINE TO TRANSFORMER LIMITED USE SEE SWITCH DETAIL ARRESTER ON ARM E 18 E D A B 30 5 TURN SWITCHES TOWARD POLE. 9 P D Q 7 B TO SYSTEM NEUTRAL D R,S 4 ÉÉ G 1 6 L ÉÉ SEE DCS SEE DCS L 50 kva & Smaller kva kVA kva & Smaller kva ENG: DG REV. NO: 7 REV. DATE: 09/02/15
61 TRANSFORMERS Three Single Phase Cluster Mounted 15 kv and Below Grounded Wye Primary Systems ** Sheet 2 of 2 NOTES: Stnd. / Stk. No. Description ** A Crossarm 10 w/ 60 V Brace B Switch, Fused, 100A, 15kV T10 D Primary Leads (ft.) (See ) E HLC*W Hot Line Clamp F Mounting Unit 3 Pos. Light ( Up To Three 50 KVA Trans. ) Mounting Unit 3 Pos. Heavy (Three KVA Trans. ) Mounting Unit 3 Pos. Xtra Hvy (Three KVA) G Transformer H Secondary Leads (Ft.) (See ) T K PG* See L ** Grounding Unit N Link, Fuse O Tag, Banked Transformer P Bracket, Crossarm, Heavy Duty Q Cover Cutout R Bolt, Mach., 3/ x S Washer, Curved, 3/ See DCS ** for secondary support and DCS ** for secondary configurations. 2. Use only one V Brace. Keep the extra brace for future use. 3. See DCS for fuse selection. 4. Use tag, Stock # to identify transformers that have been rewired internally for 120/208Y service. The tag should be attached to the secondary bushing that is no longer connected internally. See DCS These dimensions may be reduced to 2 and 48 for installation on existing pole. 6. Use DCS for ground coil application on new pole installation. Use DCS for ground rod application on existing pole installation. 7. For transformer banks greater than 500 KVA on 4KV circuits, substitute 200A fused switches stock # For all of Illinois and locations in Missouri where additional avian protection is required, omit #2 CU HD wire and hot line clamps and connect #6 CU poly covered arrester lead wire directly to the fused switch connector. 9. ONLY FOR INSTALLATION WHERE ARRESTERS CANNOT BE MOUNTED ON THE TRANSFORMER TANKS, substitute crossarm bracket with stock # and mount arresters on crossarm back to back with the fused switches. See note 8 for avian protection /4160Y transformers may have side wall or cover mounted HV bushings. If side wall mounted bushings: a. Build according to this DCS except use 2.5 KV primary lead wire per Table 2.2 of DCS , or b. If pole is congested, 2.5KV primary lead wire in conduit similar to DCS ENG: DG REV. NO: 7 REV. DATE: 09/02/15
62 CABLE TERMINALS 15 kv & Below Single Phase #2 Through 4/ ** Sheet 1 of 3 01 #2 Direct Buried or In 2 Conduit/Duct 02 4/0 Direct Buried or In 2 Conduit/Duct 03 #2 Direct Buried or In 3 Conduit/Duct 04 4/0 Direct Buried or In 3 Conduit/Duct TO LINE Z 3 #2 Cu H.D. FOR LA CONNECTION MOUNTING LIMITED TO 300 A B DO NOT GROUND BRACKET Use #4 Cu Line Lead w/ 100A Barrel Use #1/0 Cu Line Lead w/ 200A Barrel Use #1/0 Cu Line Lead w/ 300A Barrel 3 BRACKET DETAIL #2 Cu H.D. FOR GROUNDING CONNECTION TO TERMINATOR SWITCH DETAIL Ë Ë 12 Ë Ë ËËË ËË ËË U,W ËË 1 G V ËËË ËË TOP BOLT CONDUIT MUST EXTEND A MINIMUM OF 40 ABOVE THE HIGHEST COMMUNICATION ATTACHMENT AND TO THE NEUTRAL. TO LINE 11 BB TO LA F Q BB T C 11 E X 10 Z S Ë Ë Ë Y D DD SEE BRACKET DETAIL 8 J,K,L,M,P H 4 MINIMUM 8 TO LOWEST BRACKET 6 CC SWITCH DETAIL W/COVER SWEEP INSTALLED AS A PART OF CONDUIT INSTALLATION AA 7 DIRECT BURIED ENG:HLH REV. NO:21 REV. DATE: 12/16/15
63 CABLE TERMINALS 15 kv & Below Single Phase #2 Through 4/ ** Sheet 2 of 3 Stnd. / Stk. No. Description ** B Bracket,Fiberglass, 3 Position Mounting C Switch, Fused, 100A, 15kV @ D Arrester, Lightning, 9kV Arrester, Lightning, 3kV Arrester, Lightning, 10kV E Grounding Unit F Wire, Cu., #4 S.D. Covered Wire, Cu., 1/0 S.D. Covered G Conduit, Plastic, 2, SCH Conduit, Plastic, 3, SCH H Conduit, 2 SCH Conduit, 3 SCH @ J Bracket, Standoff Bracket, Standoff K Bolt, Double Arming 5/8 x M Strap. Conduit Strap. Conduit N Clamp, PG, 1/0 350 kcmil P Nut, Jam 5/ Q PG* See HLC*W Clamp, Hot line S Clamp, PG, 1/0 # T Fuse Sized By Engineer U Bolt, Mach., 5/8 x V Cable, 15kV, # Cable, 15kV, 4/ W Washer, Square, 5/ X Termination, 15kV, #2 Al Termination, 15kV, 4/0 1 1 Y Wire, #6 Cu, S.D. Covered Z Clamp, Hotline, #6 to 2/ AA Shield, Duct, Cable BB Cover Cutout, 100A Fused CC Stirrup Grounding, ½ x DD Cover Conduit OP278 Install Cable Up Pole ENG:HLH REV. NO:21 REV. DATE: 12/16/15
64 CABLE TERMINALS 15 kv & Below Single Phase #2 Through 4/ ** Sheet 3 of 3 NOTES: 1. Keep arrester ground lead as short as possible. 2. On 13 kv terminal poles use 10 kv lightning arrester, Stock # Insert a piece of #2 H.D. Cu for LA and grounding attachments. See note 11 for avian protection requirements. 4. See DCS for standoff bracket placement and grounding requirements. 5. Some standoff brackets require that one of the nuts on the double arming bolt be replaced with a jam nut. The jam nut should then be inserted into the 5/8 slot on the standoff bracket. If the nut on the double arming bolt will fit into the 5/8 slot on the bracket Do Not Use the jam nut. 6. On the front of the 20 standoff bracket, the following conduits may be mounted: 4 2 conduits, 3 2 1/2 conduits, 3 3 conduits, 3 conduits, 2 5 conduits. Various combinations of conduits may also be mounted. On the front of the 12 standoff bracket, the following conduits may be mounted: 2 2 conduits, 2 2 1/2 conduits, 1 3 & 1 2 conduits, 1 3 and 1 2 1/2 conduit, 1 conduit, and 1 5 conduit. 7. To prevent damage to direct buried cables, install a cable shield (Stk# ) at the conduit entry and increase the quantity of cable shields shown in the Materials List by Install a conduit cover at the top end of the conduit to prevent cable damage. 9. Use DCS for ground coil application on new pole installation. 10. Always connect the metallic shields of the riser cables to the system neutral with at least a #2 stranded copper wire. Be aware that the bare and/or covered 7 strand #10 copperweld ground wire may look like stranded #2 copper wire. Never substitute the copperweld ground wire for the #2 stranded copper wire when constructing the primary neutral buss. 11. For all of Illinois and locations in Missouri where additional avian protection is needed, omit the piece of #2 bare copper wire and hot line clamp Z. Connect the #6 copper poly covered arrester wire Y directly to the fused switch connector. 12. More than one single phase riser can be ona pole. Generally, installing three to four single phase risers on a pole will require the use of a crossarm. Refer to DCS ** for proper spacing of cutouts. ENG:HLH REV. NO:21 REV. DATE: 12/16/15
65 CABLE TERMINALS 15kV & Below Three Phase #2 Through 4/ ** Sheet 1 of 3 #2 3C #2 1C /0 3C /1 1C TO LINE THROUGH POLE OR DEADEND Z 3 11 #2 Cu H.D. FOR LA CONNECTION MOUNTING LIMITED TO 300 AMPS FF To Line To LA 11 AA Use #4 Cu w/ 100A Barrel Use #1/0 Cu w/ 200A Barrel Use #1/0 Cu w/ 300A Barrel #2 Cu H.D. 3 FOR GROUNDING CONNECTION SWITCH DETAIL W/COVER TO TERMINATOR SWITCH DETAIL C P G Y 2 B A X FF SEE SWITCH DETAIL DO NOT GROUND MOUNTING HARDWARE W 10 GG 12 S F,H,T,D CONDUIT MUST EXTEND A MINIMUM OF 40 ABOVE THE HIGHEST COMMUNICATION ATTACHMENT AND UP TO THE NEUTRAL N RISER TO BE LOCATED ON PROPERTY SIDE OF POLE 8 J 6 6 U SWEEP INSTALLED AS A PART OF CONDUIT INSTALLATION ENG: HLH REV. NO: 17 REV. DATE: 11/24/15 U DIRECT BURIED
Poles - General Unguyed Single Phase Composite Poles Poles - General Unguyed Three Phase Composite Poles
Standard Description 2 4 2 Poles - General Unguyed Single Phase Composite Poles 2 4 3 Poles - General Unguyed Three Phase Composite Poles 3 3 Structural Elements - Design Limits 3 1 1 Configurations -
More informationCABLE TERMINALS
14 00 00 01 Sheet 1 of 1 TABLE OF CONTENTS LOCATION & PLACEMENT OF RISERS ON JOINT USE POLES STANDOFF BRACKET PLACEMENT AND GROUNDING ONE RISER WITH U GUARD, 2, 3, 4, & 5 SPLIT CONDUIT OR SCHEDULE 40 0
More informationWILDLIFE PROTECTION
05 00 00 01 TABLE OF CONTENTS GENERAL INFORMATION INSTALLATION OF CRITTER LINE GUARDS INSTALLATION OF TANK MOUNTED LIGHTNING ARRESTER BRACKET GUARDS 25KV & BELOW EXISTING STRUCTURE MODIFICATION 05 00 00
More informationCONFIGURATIONS TABLE OF CONTENTS PHASE LOCATIONS (PREFERRED LOCATIONS) STRUCTURAL ELEMENTS DESIGN LIMITS
3 1 Sheet 1 of TLE OF CONTENTS NEUTRL LOCTIONS PHSE LOCTIONS PHSE LOCTIONS (PREFERRED LOCTIONS) STRUCTURL ELEMENTS DESIGN LIMITS NEUTRL 3 1 3 1 1 3 1 3 3 3 1 1 ** NEUTRL TP CONNECTION TO SUTRNSMISSION
More informationLABOR OPERATIONS
17 00 00 01 TABLE OF CONTENTS RECONDUCTORING 4KV LOOPOVER AND SWITCH POLE RECONDUCTORING CROSSARM OR ARMLESS 1, 2, AND 3 PHASE RECONDUCTORING ANGLE OR DEADEND RECONDUCTORING FLOATING ANGLE RECONDUCTORING
More informationTABLE OF CONTENTS GUY PLACEMENT PERPENDICULAR TO LINE PARALLEL TO LINE GUYING INSULATOR DIMENSIONAL REQUIREMENTS MINIMUM CLEARANCES GUY TO CONDUCTOR
11 00 00 01 TALE OF ONTENTS Sheet 1 of 1 GENERAL GUY PLAEMENT PERPENDIULAR TO LINE PARALLEL TO LINE GUYING INSULATOR DIMENSIONAL REQUIREMENTS MINIMUM LEARANES GUY TO ONDUTOR HART FOR SELETION OF GUY STRAND
More informationMETER INSTALLATIONS
25 00 00 01 TALE OF CONTENTS Sheet 1 of 2 SECTION INDEX 25 00 00 01 OUTDOOR POLE MOUNTED PRIAMRY METERING STRUCTURE 25 00 01 01 CUSTOMER OWNED UNMETERED D/D LIGHT INSTALLATION 25 01 05 00 PRIMARY METERING
More informationSECTION 3 - PRIMARY CONSTRUCTION OVERHEAD TABLE OF CONTENTS
03.00 GENERAL CONSTRUCTION NOTES PRIMARY CONSTRUCTION PRIMARY CONSTRUCTION PIN INSULATOR INSTALLATION 03.00-02 03.00-04 03.00-20 03.02 CONNECTORS AUTOMATIC SPLICE INSTALLATION 03.02-01 INSTALLATION GUIDE
More informationSOUTHWEST LOUISIANA ELECTRIC MEMBERSHIP COORPORATION COMMERCIAL SERVICE REQUIREMENTS
SOUTHWEST LOUISIANA ELECTRIC MEMBERSHIP COORPORATION COMMERCIAL SERVICE REQUIREMENTS November 17, 2016 Engineering Service Specifications Table of Contents Commercial Service Requirements SLEMCO Commercial
More informationSERVICE ATTACHMENT ON A BUILDING WITH BUS DUCT SERVICE ENTRANCE AND INDOOR METERING
SERVICE ATTACHMENT ON A BUILDING WITH BUS DUCT SERVICE ENTRANCE AND INDOOR METERING Obtain acceptance and specific details from the local Company office. 1. Service entrance duct (see Note 1). Company
More informationCONSTRUCTION STANDARD ELECTRIC OPERATIONS ORGANIZATION
Page 1 of 11 R1 ****This Standard Supercedes CE Macros MPR1S, MUR1S, MPR3S & MUR3S and portions of BECo Standards CS2.7-1.1, CS2.7-1.5 & CS2.7-1.7**** PRIMARY URD RISER CONSTRUCTION TABLE OF CONTENTS Page
More informationSYSTEM PROTECTION - PLATING
INTRODUCTION 1. Plates F1 thru F10 supply only the material required for one-phase. Therefore, for threephase construction, you will be required to call for the specified plate three times at that station.
More informationAMENDMENT ELECTRIC SERVICE MANUAL 2014
AMENDMENT (Pages 20,43,50,72,74,,76,78,83,86,99) ELECTRIC SERVICE MANUAL 2014 Effective April 1, 2015 18-7 6.0 SERVICE AND SERVICE ENTRANCES (General), Continued Conductor Sizing It is recommended that
More informationOUTDOOR LIGHTING
15 00 00 01 Sheet 1 of 1 TABLE OF CONTENTS GENERAL INFORMATION HID LAMPS PHOTOCONTROLS LUMINAIRE COMPONENTS HID NEMA HEAD LUMINAIRE COMPONENTS HID HORIZONTAL LUMINAIRE COMPONENTS LED BRACKET MOUNT LUMINAIRES
More informationEngineering Service Specifications. Commercial Single-Phase Current Transformer Metering Schemes
Engineering Service Specifications Commercial Single-Phase Current Transformer Metering Schemes Specifications for Commercial Underground Current Transformer Metering Requirements for a Single-Phase Customer
More informationCustomer Requirements Clearance Requirements for Overhead Joint Utility Construction
Application This standard establishes the clearances that are required on utility pole structures between electrical supply facilities owned and operated by Tacoma Power and communication facilities owned
More informationSECTION 8 - SWITCHES AND PROTECTIVE DEVICES TABLE OF CONTENTS
08.00 GENERAL DISTRIBUTION SURGE ARRESTERS 08.00-0 CUTOUTS AND ARRESTERS GENERAL 08.00-03 08.0 CUTOUTS AND ARRESTERS METAL OXIDE ARRESTERS WITH POLYMER HOUSINGS 08.0-0 APPLICATION OF DIRECT CONNECTED ARRESTERS
More informationIndex Section 103 Joint Use. General Requirements for Installation of Attachments on Oncor Poles
103 09-17 103 Index Section 103 Joint Use Title Date Number General Requirements for Installation of Attachments on Oncor Poles... 103-100 Supply and Communication Space... 103-105 Communication Lines
More informationFor mounting. cutouts, power fuses, arresters, capacitors, terminations, conduit EQUIPMENT MOUNTS
For mounting cutouts, power fuses, arresters, capacitors, terminations, conduit EQUIPMENT Index Introduction.... 1 Typical Installation.... 2 Aluminum Three Phase Cutout & Arrester Mounts.... 3 Aluminum
More informationWhen power interruptions happen.
When power interruptions happen. We know it s never a good time to have your power go out, so we work all year pruning trees and investing in our system to cut down on problems before they start. Outage
More informationOVERHEAD SERVICE. Items to consider
OVERHEAD SERVICE Items to consider The maximum length of the service wire from the ComEd pole to the point of attachment on your residence is 150 feet, if practical. Your service wire installation must
More information1100 OVERHEAD TRANSFORMERS
00 OVEHEAD TANSFOMES //00 ~ F Pole Type - Transformer Fuse Schedule ~ T Transformer Field Stenciling Code ~ TA Transformer Coding for Material Mgmt System C T,TH Pole Mounted Transformer and Cutout on
More information34.00 METERING GENERAL LABELING MULTIPLE METER ENCLOSURES ON A SINGLE PREMISE
4. METERING GENERAL LABELING MULTIPLE METER ENCLOSURES ON A SINGLE PREMISE 4.-4 4. SELF-CONTAINED METERING, SINGE-PHASE INSTALLATION DETAILS /4 VOLT SINGLE-PHASE UNDERGROUND RESIDENTIAL SERVICE AND METER
More informationIndex. Aluma Form, ALUMA-FORMEQUIPMENT MOUNTS Inc. WORLD S MOST COMPLETE LINE
Aluma Form, Index ALUMA-FORMEQUIPMENT MOUNTS Inc. Introduction.............................. 3 Typical Installation......................... 4 Aluminum Three Phase Cutout & Arrester Mounts..........................
More informationUG FEEDING OH UG FEEDING OH. Electric Distribution Standards I. INTRODUCTION
I. INTRODUCTION Electric Distribution Standards Design, Construction & Material Standards formed a special committee to establish some basic design guidelines for construction alternatives to be used for
More informationItem Code Description Unit Qty Total
UNDP ELECTRICITY SECTOR NORTHERN GOVERNORATES Phase XI Item Code Description Unit Qty Total 04-02-00001 Service Pole - 6m, 75mm dia GS Pipe 11250 04-02-00002 9m Tubular Steel Poles complete with all Accessories
More informationURD Mini Pillar Installation Guide. UDS Universal Pillar Installation Guide. Cable to LV Isolators, Crossarm and Cable Detail
Part 5 LV Underground Drawing Register Number U8 U9 Description URD Mini Pillar Installation Guide UDS Universal Pillar Installation Guide U10-1 UDS Universal Pillar Double Link Unit Drilling Detail U10-2
More informationSingle phase pole mounted. 11kV. Electrical Engineer KEU ID#:
Single phase pole mounted Distribution Transformers 11kV Prepared by: ARY SAIDAHMED SHEKSAEED Electrical Engineer KEU ID#: 4252 Email: ary.sayd@hotmail.com 1 S # Contents Page # 1 Introduction 3 2 Type
More information7 Single Family Service
7 Single Family Service 7. General The location of the service entrance on the Customer s premises is an important consideration. For clearance and location information see section 5 (Clearances). Consult
More informationWildlife Power Outage Protection Products
Wildlife Power Outage Protection Products BirdguarD Line www.kaddas.com KADDAS Enterprises Inc. Avian Protection Plan (APP) Your Total Wildlife Outage Protection Solution An Avian Protection Plan is a
More information10 Commercial, Industrial, Agricultural Services
10 Commercial, Industrial, Agricultural Services This section describes the Power Company requirements for commercial, industrial, and agricultural services. This section covers single phase and three
More informationUNDERGROUND SERVICES - SECONDARY
UNDERGROUND SERVICES - SECONDARY Contents - Underground Services... U-1 General Requirements for Underground Service...U-2 Names of Parts for Underground Service... U-3 Service Termination in a Service
More informationWPS SERVICE MANUAL. Section Amp and Smaller - Common
Revised 01/2017 Section 2 200 AMP AND SMALLER - COMMON Page 1 of 17 Section 2 200 Amp and Smaller - Common 2-0 General Metering Requirements... 2 2-1 Basic Calculations... 4 2-2 100-200 Amp Single-Phase
More informationD9-3. No. WIRING DIAGRAM CONNECTIONS FOR UNDERGROUND SELF CONTAINED METERS JRH JED krich95 LINE LINE ABCN SOURCE SOURCE GROUND GROUND STUD STUD SOURCE
SOURCE 20V 240V STUD (PER NEC) A customer supplied and installed teaser wire is required from the neutral lug to a 5th terminal mounted on the left side of the meter block between the line and load terminals.
More informationRISER POLES RISER POLES. Overhead Electric Distribution Standards INTRODUCTION
INTRODUCTION. For proper fuse coordination, refer to the SYSTEM PROTECTION section to select the appropriate fuse for underground risers.. Terminators or Potheads and their mounting brackets are included
More informationAGRICULTURAL UNDERGROUND SERVICE 500 HP OR LESS
Prepared by: ABB1 AGRICULTURAL UNDERGROUND SERVICE 500 HP OR LESS 05619 Asset Type: Electric Metering Function: Design and Construction Issued by: Lisseth Villareal (LDV2) Date: 07-31-15 Rev. #10: This
More informationCatalog 14A January 2013
Catalog 14A January 2013 Page 1 January 2013 Type AR (Automation-Ready) Switch 14.4kV, 25kV or 34.5kV 900 Amperes Continuous/Interrupt Description The Hubbell unitized Type AR switch is a distribution-level,
More informationCAT-1 Series 3. Installation Guide. The Valley Group, Inc. 871 Ethan Allen Hwy. Suite 104 Ridgefield, CT 06877
CAT-1 Series 3 Installation Guide The Valley Group, Inc. 871 Ethan Allen Hwy. Suite 104 Ridgefield, CT 06877 (203) 431-0262 (203) 431-0296 FAX tvg@cat-1.com Installation of Load Cells for CAT-1 Systems
More informationTEMPORARY ELECTRIC WIRING FOR CARNIVALS, CONVENTIONS, EXHIBITIONS, FAIRS AND SIMILAR USES
INFORMATION BULLETIN / PUBLIC - ELECTRICAL CODE REFERENCE NO.: LAMC 93.0230 Effective: 3-24-69 DOCUMENT NO. P/EC 2002-006 Revised: 11-17-00 Previously Issued As: RGA #7-69 TEMPORARY ELECTRIC WIRING FOR
More informationPART NUMBER POLE DIAMETER RANGE CARTON QTY " to 5" " to 6 3 4" " to 7 3 4" " to 8 3 4" 10
PH1 Offset Pole Band Bands Single Double Offset Pole Bands are used for dead-ending, guying, and mounting secondary racks on metal poles, pipe masts, or conduit. Each Pole Band Assembly contains two 1
More informationUNDERGROUND SERVICE ENTRANCE LOCATION. No meter base or entrance should be installed before an KREMC engineer has checked the proposed location.
UNDERGROUND SERVICE No meter base or entrance should be installed before an KREMC engineer has checked the proposed location. Entrance cabinet must be directly through wall or directly under meter in basement.
More informationDisconnect & ByPass Switches
Disconnect & ByPass Switches Disconnect & Oil Circuit Recloser Bypass Switches; Regulator & Current Transformer Bypass Switches Electrical Apparatus K-SEC 060 & 090 Contents Type D-73 Distribution Class
More informationUNDERGROUND SERVICE ENTRANCE LOCATION. No meter base or entrance should be installed before an KREMC engineer has checked the proposed location.
UNDERGROUND SERVICE No meter base or entrance should be installed before an KREMC engineer has checked the proposed location. Entrance cabinet must be directly through wall or directly under meter in basement.
More information12. ILLUSTRATIONS 12.1 GENERAL
12. ILLUSTRATIONS 12.1 GENERAL Illustrations of typical service equipment and installations are shown in this section as an aid to interpretation of these Electric Service Requirements. The illustrations
More informationPentahead bolts See note 2. Conduit run as specified. Company facility. Refer to drawing SS8.6-2 or SS8.6-3 STANDARD SERVICE INSTALLATION
PULL BOX F SECONDARY SYSTEM Typical grade Pentahead bolts See note 2 Conduit run as specified Plastic or fiberglass for grass areas or Polymer concrete for light duty areas (see notes 2, 3, & 4) Company
More information/1-141 ///_=///E ///_=//47/1_=//
NOTES: 1. Ground wire to be located on same side as neutral conductor and in quadrant opposite climbing space or pole top pin. 2. Staples on ground wire shall be 2'.-0 apart except for a distance of 8'
More informationSteel Fabrications Equipment Brackets
April 2004 Page 25 of 43 H. R. Steel; Each bracket includes (2) 1/2 x 1 hex bolts, flat washers, and special retaining clips as well as (1) 1/2 x 2 captive carriage bolt, shake proof washer, lockwasher,
More informationBRACKETS, MOUNTS & HARDWARE
HIGH VOLTAGE SWITCHGEAR & AUTOMATION EQUIPMENT SECTION 6 Brackets, Mounts & Misc. Hardware CAT. NO: 040930G May, 2008 INERTIA Engineering & Machine Works, INC. Fax: (209) 931-8186 6665 Hardaway Road, Stockton,
More informationTM OUR PRODUCTS INDIA Accurate, reliable and free from any defect, we provide the best quality Electrical Porcelain and Polymer Insulators, Hardware Fittings and protection Switches at an economical price.
More informationJumpers & Load Pickup Tools
Jumpers & Load Pickup Tools Catalog 2300 May 2016 Jumpers & Load Pickup Tools 2300 May 2016 Page 2301 All Chance Insulated Jumpers meet ASTM F 2321 Standard Specification. G4758 15kV 5 5 / 8 " G4765 25kV
More informationCustomer Substation Manual
Customer Substation Manual Table of Contents Section Page 2 of 81 Description 0 Preface 010.00 General 010.10 Information Required for the Review of New Customer Substations 010.20 New Customer Substation
More informationMCM CABLE 3/15/2010
00 000 MCM CABLE //00 C UEE Elbow Enclosure - Deadend C UEE Elbow Enclosure - Feed-Through C UP 000 MCM Cable iser ~ UP 000MCM Power Cable iser Grounding Detail N UP 000 MCM Cable iser with Ø Switch N
More informationTYPE BLT DISCONNECT SWITCHES
TYPE BLT DISCONNECT SWITCHES OUTDOOR-HOOK OPERATED 8.3KV through 38KV A & A Current Furnished with hooks for loadbreak tool REA/RUS approved S M C O 1 BLT PARALLEL BLADE DISTRIBUTION CLASS DISCONNECT SWITCH
More information9. Non-Residential Services (Commercial, Industrial, and Agricultural)
Section 9 2016 Electric Service Requirements, 3rd Edition Section 9 Non-Residential Services Directory Page 9.1 General Requirements 68 9.2 Direct-Connect Metering, Single Installations 69 9.3 Direct-Connect
More informationSECTION 27 - PAD-MOUNTED TRANSFORMERS TABLE OF CONTENTS
CABLE AND CONDUIT ENTRANCE SINGLE-PHASE PAD-MOUNTED TRANSFORMER INSTALLATION 100 KVA AND LARGER (CONCRETE PADS ONLY) 27.05-01 CABLE AND CONDUIT ENTRANCE SINGLE-PHASE PAD-MOUNTED TRANSFORMER INSTALLATION
More informationM-Force three-phase switch
Switches and Disconnects CA008004EN Supersedes May 2015 COOPER POWER SERIES M-Force three-phase switch Description Eaton's Cooper Power series M-Force switch is a distribution-class, gang-operated, factory
More informationFor Conduit Inspections
Underground Conduit Standards - Table of Content 5/8/2017 Section S22 Underground Conduit Standard Index: Description: 00 Table of Content 01 General Notes 02 Definition of Terms 03 Primary Riser Conduit
More informationGAINESVILLE REGIONAL UTILITIES APPROVED ELECTRIC SYSTEM MATERIALS MANUAL Page 1 ACTIVE MATERIAL INDEXED ALFHABETICALLY. Rev.
Page 1 ACTIVE MATERIAL INDEXED ALFHABETICALLY ANCHOR, DROP-IN FOR 1/2" BOLT 18564-7 A-11.00 11/2/2016 ANCHOR, DROP-IN FOR 3/9" BOLT 18549-3 A-11.00 11/2/2016 ANCHOR, NO-WRENCH: 10" X 96" 01558-6 A-5.00
More informationCustomer Requirements Pole Attachment Requirements for Telecommunications (non-rf)
Application This standard establishes the attachment requirements to utility pole structures owned and operated by Tacoma Power and communication facilities owned and operated by others. This standard
More informationSpecifications. S&C Type XS Fuse Cutouts. Outdoor Distribution (4.16 kv through 25 kv)
Outdoor Distribution (4.16 through 25 ) Specifications Conditions of Sale STANDAD: Seller s standard conditions of sale set forth in Price Sheet 153 apply, except as modified under WAANTY QUALIFICATIONS
More informationType L Cutouts. UltraSIL Polymer-Insulated and Porcelain Type L Open Distribution Cutout. Description
Type L Cutouts UltraSIL Polymer-Insulated and Porcelain Type L Open Distribution Cutout Electrical Apparatus 327-30 Description Cooper Power Systems has set a new standard of excellence for polymer distribution
More informationCABINET - CURRENT TRANSFORMER Indoor - Outdoor 240 Volts Amperes Maximum
PAGE 1 OF 5 USE: 1. For commercial and industrial installations purchased and installed by the Customer. 2. For use on the following services: 1 phase 3 wire 240 volts, 3 phase 3 wire 240 volts, 3 phase
More information7. Residential Single-Family and Duplex Buildings (Dwellings)
Sin g le -F a mily a n d Du p le x Bu ild in g s 2016 Electric Service Requirements, 2 nd Edition Section 7 Section 7 Residential Single-Family and Duplex Buildings (Dwellings) Directory Page 7.1 General
More informationSentinel Field Satellite Controller Metal Pedestal, Plastic Pedestal and Wall Mount Models Installation Instructions
WARNING HIGH VOLTAGE 115V 4 M AP Sentinel Field Satellite Controller Metal Pedestal, Plastic Pedestal and Wall Mount Models Installation Instructions Important: For your protection and the safety of the
More informationALUMA FORM LIGHT WEIGHT MOUNTS FOR TRANSFORMERS
PRIMARY METERING MOUNT CATALOG ALUMA FORM LIGHT WEIGHT MOUNTS FOR TRANSFORMERS ALUMA-FORMprimary metering mounts All aluminum, light weight construction for mounting current and potential transformers
More informationList of materials for 1Km. Of L.T line 1-Ph., 2-Wire AB cable (1 X 25+1X16) sq.mm using 8M X 200 KG. PSC Pole
List of materials for 1Km. Of L.T line 1-Ph., 2-Wire AB cable (1 X 25+1X16) sq.mm using 8M X 200 KG. PSC Pole 1 L.T Stay set Complete Set 5 2 7/12 GI stay wire kg 50 3 Concreting of stay NO 5 4 Stay clamp
More informationSTRAIN LINK STICK ROLLER LINK STICK ADJUSTABLE STRAIN POLES SPIRAL LINK STICK TRANSMISSION TOOLS
172 Phone: 800-323-6606 Fax: 847-488-1285 www.hilineco.com STRAIN LINK STICK Used as insulation between rope blocks and a hot line wire grip For deadend structures and running corners Attached to conductor
More informationType M3 Hookstick Disconnect Switches Up to 38kV 600 or 900 Amp 40kA Momentary
14B-2 Type M3 Hookstick Disconnect Switches Up to 38kV 0 or 900 Amp 40kA Momentary Application The Chance Type M3 Disconnect Switch is a single-phase hookstick operated switch. It is for manual switching
More informationTHE DAYTON POWER AND LIGHT COMPANY Original Sheet No. 15 DPL Building Courthouse Plaza Southwest Dayton, Ohio P.U.C.O. NO. 1
THE DAYTON POWER AND LIGHT COMPANY Original Sheet No. 15 SCHEDULE 1 Schedule of fees and charges used for determining sacrifice value, excess height and/or strength and sale costs of poles. Year % Set
More informationTechnical Specification for Pole Mounted Capacitor Rack
Technical Specification for Pole Mounted Rack Page 1 1. Scope and Function a) Pole mounted capacitor racks shall be installed on a distribution feed as an economical means of applying capacitor units to
More informationLight Weight Mounts for Transformers PRIMARY METERING MOUNTS
Light Weight Mounts for Transformers PRIMARY All aluminum, light weight construction for mounting current and potential transformers for primary metering hookups. Mount comes as shown ready to be made
More informationMK IV OVERHEAD DOOR REPLACEMENT PARTS BOOK
MK IV OVERHEAD DOOR REPLACEMENT PARTS BOOK JAMISON DOOR COMPANY P.O. BOX 70 HAGERSTOWN, MARYLAND 21740 1-800-532-3667 301-733-3100 INTERNET: http://www.jamisondoor.com E-MAIL: contact@jamisondoor.com ECN
More informationStandard Compression Dead End for ACSR and ACSS Conductor CAUTION: ACSR Dead Ends Cannot Be Used on ACSS HT Conductor
INS-ACA089 Installation Instructions Standard Compression Dead End for ACSR and ACSS Conductor CAUTION: ACSR Dead Ends Cannot Be Used on ACSS HT Conductor 1. Mark the conductor a distance of 3 /4 the length
More informationM-Force three-phase switch
Supersedes K-SEC 926 December 2012 M-Force three-phase switch Description The M-Force switch from Eaton's Cooper Power Systems is a distribution-class, gangoperated, factory unitized three-phase overhead
More informationMINIMUM DISTRIBUTION SYSTEM CONCEPTS AND APPLICATIONS. Larry Vogt. Manager, Rates
MINIMUM DISTRIBUTION SYSTEM CONCEPTS AND APPLICATIONS Larry Vogt Manager, Rates Minimum Distribution System What is MDS? MDS is an analysis module of the cost-of-service study in which distribution investment
More informationJUMPERS & SWITCHING TOOLS
INSULATED JUMPER SETS 368 INSULATED JUMPER SETS FOR 15 KV, 25KV AND 35 KV Used for bypassing work areas when upgrading lines and when making temporary or emergency repairs Continuous-current ratings for
More informationT & D Inventory Items Bidder Price List Group 1: 120V/240V Pole Mounted Transformers ASPA ITEM NO.
T & D Inventory Items Bidder Price List Group 1: 120V/240V Pole Mounted Transformers No ASPA ITEM NO. 1 69361525 2 69361537 3 69361550 Group 2: Poles DESCRIPTION Make/Model Cat/Spec QTY UNIT MEASURE UNIT
More informationSECTION LOW VOLTAGE DISTRIBUTION EQUIPMENT
SECTION 16400 LOW VOLTAGE DISTRIBUTION EQUIPMENT A. General 1. The University does not accept Series-Rated equipment for power distribution switchboards, distribution panels and branch circuit panelboards.
More informationSPECIFICATIONS FOR COMMERCIAL CONSTRUCTION
Roseville Electric SPECIFICATIONS FOR COMMERCIAL CONSTRUCTION REVISED 06/28/18 Commercial Construction Specifications Revision List REVISION Date Page No. Description 03/01/00 4.2-4.3 Changed leveling
More informationCOOPER POWER SERIES. UltraSIL polymer-insulated D-73P disconnect switches installation instructions. Switches MN008004EN
Switches MN008004EN Effective April 2016 Supersedes S328-10-1 June 2013 COOPER POWER SERIES UltraSIL polymer-insulated D-73P disconnect switches installation instructions DISCLAIMER OF WARRANTIES AND LIMITATION
More informationCABINET - CURRENT TRANSFORMER Indoor - Outdoor 240 Volts Amperes Maximum
PAGE 1 OF 5 USE: 1. For commercial and industrial installations, purchased and installed by customer. 2. For use on the following services: 1 phase 3 wire 240 volts, 3 phase 3 wire 240 volts, 3 phase 4
More informationService Requirements
Service Requirements General Contact Idaho Power before beginning work on any new service. All meter installations must meet current electrical code requirements and display the proper electrical permit.
More informationProduct Specifications for Phase Over Phase GOABS(r)
1. General a) This specification covers the design, manufacture, and shipment of phase-over-phase, 1-way, 2-way, 3-way, and 4-way, gang-operated disconnecting switches, both air-break and load-break, for
More informationDistribution Arresters
Heavy Duty & Riser Pole Ÿ Tested to the latest IEEE C62.11 standards Ÿ High Strength Fiberglass Isolator Brackets Ÿ Ground Lead Disconnect will operate with a minimum of 1 amp Ÿ Protective Cap RUS APPROVED
More informationK-Limiter high ampere Companion II fuse
Fusing Equipment Catalog Data CA132059EN Supersedes February 2016 COOPER POWER SERIES K-Limiter high ampere Companion II fuse General Eaton designs its Cooper Power series K-Limiter fuse to be conveniently
More informationCHAPTER V RESIDENTIAL WIRING
CHAPTER V RESIDENTIAL WIRING 5.1. THE SERVICE ENTRANCE Buildings and other structures receive the electrical energy through the service entrance. In residential wiring, the electric company supply this
More informationCLARK PUBLIC UTILITIES TECHNICAL SPECIFICATIONS THREE-PHASE PADMOUNTED TRANSFORMERS
CLARK PUBLIC UTILITIES TECHNICAL SPECIFICATIONS THREE-PHASE PADMOUNTED TRANSFORMERS Originated 1/85 Revised 6/95 Revised 6/02 Revised 11/05 Revised 4/08 Revised 11/09 Revised 1/12 Revised 11/12 Revised
More informationTransmission Tools. Catalog 2250 May Transmission Tools Phone: Web: hubbellpowersystems.
Transmission Tools Catalog 2250 May 2016 Transmission Tools 2250 May 2016 Page 2251 STRAIN LINK STICK Tested per OSHA & ASTM F711 Used as insulation between rope blocks and a hot line wire grip For deadend
More informationCOMMERCIAL QUICK REFERENCE
COMMERCIAL QUICK REFERENCE PROVO CITY POWER STANDARDS ELECTRICAL ENGINEERING UPDATED: 2016 SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTIFICATION. 18" MIN. OF TAIL. (NEUTRAL CONDUCTOR MUST BE WHITE OR
More informationSYSTEM PROTECTION SYSTEM PROTECTION. Underground Electric Distribution Standards I. FUSE COORDINATION
I. FUSE COORDINATION I.1. GENERAL I.1.1. The purpose of protective coordination is to provide isolation of a fault as close to the fault as possible so that a minimum of customers will be affected. The
More informationUPPCO SERVICE MANUAL
Revised 01/2015 Section 6 ELECTRIC SERVICE - GENERAL Page 1 of 10 Section 6 Electric Service - General 6-1 Number of Services and Voltages / Meter... 2 6-2 Energy Conversion Factors... 7 6-3 Lightning
More informationENTRANCE EQUIPMENT ER D PAGE 1 OF 5
PAGE 1 OF 5 USE: Requirements for entrance equipment. PREVIOUS REVISION 07-01-98 ORIGINATED 03-94 PREVIOUS NUMBER ER 100 (12-01-81) LATEST REVISION: Updated meter socket labeling specification and instrument
More informationCustomer Requirements Downtown Secondary Network Service
Application This standard describes the limitations and requirements for receiving service from the Tacoma Power secondary network system within the City of Tacoma downtown core area. In This Standard
More informationRevised: April 2018 ¹ SERVICE TO WIRELESS DEVICE ANTENNA ATTACHMENTS ON CUSTOMER SERVICE POLES (SHEET 1) CUSTOMER: 1. An overcurrent protective device including a disconnect switch shall
More informationMK IV HORIZONTAL SLIDING DOOR REPLACEMENT PARTS BOOK
MK IV HORIZONTAL SLIDING DOOR REPLACEMENT PARTS BOOK BI-PARTING DOOR SHOWN-SINGLE DOOR SIMILAR JAMISON DOOR COMPANY P.O. BOX 70 HAGERSTOWN, MARYLAND 21740 1-800-532-3667 301-733-3100 INTERNET: http://www.jamisondoor.com
More informationEasy-On II Terminations
Features Class 1 (outdoor) termination as defined in IEEE 48 standard. For use on all extruded dielectric cables, concentric neutral, metal tape shielded or wire shielded cables without need for additional
More informationMATERIAL FOR FIBRE OPTIC LINES. General C-bracket HSU trunnion type, forged, for aluminium based OPGW conductors...
153 Contents General.................................................................................................. 154 C-bracket.................................................................................................
More informationELECTRIC SERVICE RULES UTILITY/CATV SERVICES Issued Jan 2016
UTILITY/CATV SERVICES CHAPTER 9 900. GENERAL A. Alliant Energy receives many requests for electric service from other utilities; telephone, telecommunications companies, cable television, the Department
More informationGAINESVILLE REGIONAL UTILITIES APPROVED ELECTRIC SYSTEM MATERIALS MANUAL Page 1 ACTIVE MATERIAL INDEXED ALFHABETICALLY. Rev.
Page 1 ACTIVE MATERIAL INDEXED ALFHABETICALLY ANCHOR, DROP-IN FOR 1/2" BOLT 18564-7 A-11.00 9/12/2011 ANCHOR, DROP-IN FOR 3/9" BOLT 18549-3 A-11.00 9/12/2011 ANCHOR, NO-WRENCH: 10" X 96" 01558-6 A-5.00
More informationTRI-SERVICE ELECTRICAL WORKING GROUP (TSEWG) 03/05/09 TSEWG TP-11: UFC N BEST PRACTICES
TSEWG TP-11: UFC 3-500-10N BEST PRACTICES UFC 3-500-10N was developed by NAVFAC and was used as the starting point for the tri-services development of UFC 3-500-10, Design: Electrical Engineering. UFC
More information