T & D Inventory Items Bidder Price List Group 1: 120V/240V Pole Mounted Transformers ASPA ITEM NO.
|
|
- Chrystal Cameron
- 6 years ago
- Views:
Transcription
1 T & D Inventory Items Bidder Price List Group 1: 120V/240V Pole Mounted Transformers No ASPA ITEM NO Group 2: Poles DESCRIPTION Make/Model Cat/Spec QTY UNIT MEASURE UNIT PRICE TRANSFORMER 25 KVA, POLE MOUNTED, 1 PHASE, 60 Hz, 13.2KV/7.62KV GRD Y PRIMARY, 120/240 VOLT SECONDARY, 2 HV BUSHINGS 35KV 150KV BIL 30" CREEP WITH BIRDGUARDS, 304L STAINLESS STEEL TANK AND COVER, 1X10KV MOV ARRESTOR WITH STAINLESS STEEL BRACKET. Open N/A 3 EACH TRANSFORMER 37.5 KVA, POLE MOUNTED, 1 PHASE, 60 Hz, 13.2KV/7.62KV GRD Y PRIMARY, 120/240 VOLT SECONDARY, 2 HV BUSHINGS 35KV 150KV BIL 30" CREEP WITH BIRDGUARDS, 304L Open N/A 6 EACH STAINLESS STEEL TANK AND COVER, 1X10KV MOV ARRESTOR WITH STAINLESS STEEL BRACKET. TRANSFORMER 50 KVA, POLE MOUNTED, 1 PHASE, 60 Hz, 13.2KV/7.62KV GRD Y PRIMARY, 120/240 VOLT SECONDARY, 2 HV BUSHINGS 35KV 150KV BIL 30" CREEP WITH BIRDGUARDS, 304L STAINLESS STEEL TANK Open N/A 3 EACH AND COVER, 1X10KV MOV ARRESTOR WITH STAINLESS STEEL BRACKET. NOTE 1: ALL TRANSFORMERS TO BE FILLED WITH NON PCB MINERAL OIL NOTE 2: TAP SETTINGS: TAP A: 100% 7620 V, TAP B: 97.50% 7420 V, TAP C: 95% 7230 V, TAP D: 92.50% 7040 V, TAP E: 90% 6850 V POLES 30FT.CLASS 4, SOUTHERN YELLOW PINE or DOUGLAS FIR Group 3: Cable and Conductor SY Pine or Douglas Fir ATTACHED 100 EACH CABLE UNDERGROUND 15KV, 1/0 CU STRANDED MIL 133%, CONCENTRIC NEUTRAL, EPR 3X STEEL DRUMS *(2600FT PER DRUM) Open Per Description 7800 FEET CONDUCTOR,BARE #2-7STR,HD.CU. Open #2-7 HD Cu 20,000 FEET Group 4: Metering METER KWH 240 V.1 PH.3-WIRE.1-STATOR TEST AMPS 30.FORM 2S. NUMERAL TYPE ELSTER TYPE AB1 STYLE 5570C48G EACH METER,RING STAINLESS STEEL.KWH INNERTITE E-S6900H 500 EACH EXTENDED COST
2 Group 5: Underground ELBOW 15KV LOADBREAK 1/0 STR Cu ELASTIMOLD 166LR-B RISER TERMINATION 15KV FOR 1/0 SOLID ALUMINUM ELASTIMOLD PCT /0 21 EACH BUSHING 15KV PARKING. ELASTIMOLD 161SOP 60 EACH 12 NEW JACKET SEALS (OD.80 to 1.50 inches) 200 ECS ELASTIMOLD 200ECS 13 NEW JACKET SEALS (OD 1.28 to 2.30 inches) 600 ECS ELASTIMOLD 600ECS 14 NEW ELBOW SURGE ARRESTOR ELASTIMOLD 167ESA EACH 15 NEW WINDOW OP L/BREAK ELBOW TAP PLUG 15 KV ELASTIMOLD 650ETP 18 EACH 16 NEW STICK OP L/BREAK ELBOW TAP PLUG 15 KV ELASTIMOLD 650LRTPA3 18 EACH 17 NEW STICK OP BUSHING ADAPTER 15 KV ELASTIMOLD 650BEA3 18 EACH 18 NEW GROUNDING ELBOW 15 KV (1/0 AWG x 6ft LEAD) ELASTIMOLD 160GLR 6 EACH ELBOW 15KV LOADBREAK FOR # 2 STRANDED Cu ELASTIMOLD 166LR-B JUNCTION,3-WAY."STAINLLESS STEEL" ELASTIMOLD J164J3BX 36 EACH JUNCTION,4-WAY."STAINLESS STEEL" ELASTIMOLD J164J4BX 36 EACH JUNCTION,3-WAY,"ALUMINUM PLATE" ELASTIMOLD K650-J3BX 12 EACH PULLING TAPE 5/8"X 3000FT BLOWING TWINE 100% POLYESTER ne_blowing.htm ne_blowing.htm PAIL PAIL
3 Group 6: Streetlighting LUMINAIRES,COMPLETE STREETLIGHT 70WATTS GENERAL ELECTRIC GE- SAM07S1N5S4 500 EACH LUMINAIRES,PHOTO ELECTRIC CONTROL FISHER PIERCE 7790B-SSS 1000 EACH LUMINAIRES,STREETLIGHT SHADE YARD TYPE GENERAL ELECTRIC GE SA-V5AL 300 EACH LUMINAIRES,LAMP 250W.120V GENERAL ELECTRIC LU EACH LUMINAIRES,BALLAST.70W/HPS-120V W/O SHAD GENERAL GE- ELECTRIC SAH07S1N2N1 400 EACH LUMINAIRE, BALLAST 250W HPS ROADWAY TYPE COOPER LIGHTING OVZ25SWW2E COUPLINGS BREAKAWAY FOR LIGHTPOLES VALMONT LEXINGTON 6 EACH SKIRT 2 PIECE ALUMINUM FOR LIGHTPOLES VALMONT LEXINGTON 6 EACH LIGHTPOLE ALUMINUM ANCHOR BASE 30FT VALMONT LEXINGTON 6 EACH ALUMINUM,STR.LIGHT ARM 1-1/4"X4 FT HAPCO EACH ALUMINUM ARM 1-1/4"X 2 FT HAPCO EACH
4 Group 7: Connectors CONNECTOR,COMPRESSION #2 RUN #2 BURNDY YC2C EACH CONNECTOR,COMPRESSION #2 RUN #4. BURNDY YC2C EACH CONNECTOR,COMPRESSION #4 RUN #4TAP BURNDY YC4C EACH CONNECTOR,COMPRESSION #4 RUN #6TAP BURNDY YC4C EACH SPLICE, COMPRESSION, #2STR TENSION BURNDY YDS2C 500 EACH SPLICE, COMPRESSION, #4STR TENSION BURNDY YDS EACH LUG COMPRESSION FOR2/0 COPPER BURNDY YA26-2N 100 EACH LUG, COMPRESSION 500 MCM BURNDY YD EACH LUG 2 HOLE COMPRESSION 750 KCMIL BURNDY YA39-2N LUG,TRANSFORMER GROUND 8SOL.2STR BURNDY EQC632C 300 EACH
5 Group 8: Bolts BOLT,CARRIAGE.1/2" X 6" JOSLYN J8646-E 500 EACH BOLT,DOUBLE ARMING 5/8"X18" JOSLYN J8868*E 100 EACH BOLT,DOUBLE ARMING 5/8"X20" JOSLYN J8870*E 100 EACH BOLT,DOUBLE ARMING 5/8"X22" JOSLYN J8872*E 100 EACH BOLT,DOUBLE ARMING 5/8"X24" JOSLYN J8874*E BOLT,DOUBLE ARMING 5/8"X26" JOSLYN J8876*E BOLT,OVAL EYE 5/8"X20" JOSLYN J9420*E 100 EACH BOLT,MACHINE 5/8"X10" JOSLYN J8810*E 500 EACH BOLT,MACHINE 5/8"X12" JOSLYN J8812*E 1000 EACH BOLT,MACHINE 5/8"X14" JOSLYN J8814*E 500 EACH BOLT, MACHINE 5/8"X16" JOSLYN J8816*E 200 EACH WASHER,CURVED 3X3X5/16" 11/16" JOSLYN J EACH WASHER,SQ 2-1/4"X2-1/4"X1/4" 13/16" JOSLYN J EACH NUT,LOCK 5/8" DIAMETER BOLT JOSLYN J8583 (E) 1000 EACH
6 Group 9: Line Hardware BRACKET,CLEVIS W/O INSULATOR JOSLYN J EACH BRACKET,WIREHOLDER PIPE MOUNT. JOSLYN J0588Z 500 EACH BRACKET, POLE TOP JOSLYN J EACH CLAMP,DEADEND STRAIGHT-LINE #6-2/0 ANDERSEN BDE46N 200 EACH STUD,LONG 3/4"POST INS.5/8"X7-9/16" JOSLYN J EACH STUD,SHORT 3/4"POST INS.5/8"X1-3/4" JOSLYN J EACH INSULATOR,SPOOL 3"HIGH 1-3/4"GRV JOSLYN J EACH COMPOUND,JOINT OXIDE,COPPER TO COPPER PENETROX E-8 24 EACH SEALANT,DUCT BARNCO S TAPE,PLASTIC 33+ 3/4"X60FT 3M EACH Group 10: Anchors & Guys ROD,ANCHOR 3/4"X8',TWIN EYE(HDG) JOSLYN J7528*E 200 EACH ANCHOR,EXPANDING 8-WAYS.GALV.STEEL JOSLYN J EACH PREFORMED,GUY GRIP.ALUMOWELD 10M. PLP AWDE EACH GUARDS GUY WIRE,7FT YELLOW HELICAL CHANCE 84FRPM-YEL 300 EACH
7 Group 11: Fusing, Cutouts FUSE,LINK 2-AMPS,T-TYPE (NEW) CHANCE M2TA EACH FUSE,LINK 3-AMPS,T-TYPE CHANCE M3TA EACH FUSE,LINK 4-AMPS,T-TYPE CHANCE M4TA EACH FUSE,LINK 5-AMPS,T-TYPE CHANCE M5TA EACH FUSE,LINK 6-AMPS,R/HEAD T-TYPE CHANCE M6TA EACH FUSE,LINK 8-AMPS,R/H.T-TYPE CHANCE M8TA EACH FUSE,LINK 10-AMPS,R/H,T-TYPE CHANCE M10TA EACH FUSE,LINK 40-AMPS,R/H.T-TYPE CHANCE M40TA EACH FUSE,LINK 50-AMPS,R/H.T-TYPE CHANCE M50TA EACH CUTOUT,FUSE TYPE,100AMPS,15KV.95BIL CHANCE C PB 200 EACH ARRESTER,10KV,DISTR COOPER ENERGY UHG10050A1A1B1 A 60 EACH INSULATOR,25KV F-NECK POST TIE-TOP CHANCE C
8 Group 12: Conduits, Fittings COUPLINGS SCH-40 X 2" OPEN COUPLINGS SCH-40 X 2-1/2" OPEN COUPLINGS SCH-40 X 3" OPEN COUPLINGS SCH-40 X 4" OPEN END CAPS 2-1/2" SCH-40 OPEN END CAPS 5" SCH 40 OPEN END CAPS (BELL TYPE) 2" SCH-40 OPEN END CAPS (BELL TYPE) 2-1/2" SCH-40 OPEN END CAPS (BELL TYPE) 3" SCH-40 OPEN END CAPS (BELL TYPE) 4" SCH-40 OPEN END CAPS (BELL TYPE) 5" SCH-40 OPEN ELBOWS 2" SCH-40 X 90 DEG 30" RADIUS OPEN ELBOW 2-1/2" SCH40 45 DEGREE X 24"RADIUS OPEN ELBOWS 2-1/2" SCH-40 X 90 DEG 30" RADIUS OPEN ELBOWS 3" SCH40 45 DEGREE 24" RADIUS OPEN ELBOWS 3" SCH-40 X 90 DEG 30" RADIUS OPEN ELBOWS 4" SCH40 45 DEGREE 24" RADIUS OPEN ELBOWS 4" SCH-40 X 90 DEG 30" RADIUS OPEN ELBOW 4" SCH40 90 DEG 36" RADIUS OPEN ELBOWS 5" SCH40 45 DEGREE 24" RADIUS OPEN ELBOWS 5" SCH-40 X 90 DEG 30" RADIUS OPEN ELBOWS 5" SCH40 90 DEG 36" RADIUS OPEN 25 EACH 100 EACH
9 Group 13: Vaults CABINET 3 PHASE SECTIONALIZING(F/GLASS) NORDIC FIBERGLASS ND-430-MG W3A 2 EACH SUB TOTAL GRAND TOTAL $0.00 $0.00
11. CABLE SPECIFICATIONS 5kV, 15kV, AND 35kV RUBBER OR PLASTIC INSULATED CABLE
11. CABLE SPECIFICATIONS 5kV, 15kV, AND 35kV RUBBER OR PLASTIC INSULATED CABLE 11.1 GENERAL Only single conductor cables as described in this section are acceptable for connection to PECO Energy Company
More information600A Deadbreak Elbow. K656LR Elbow Connector (with Test Point) Features:
Issue Date: 07/17/2017 Page: 1 of 5 PSS- K656LR Elbow Connector (with Test ) Applications: The Elastimold K656LR (with test point) is designed to provide fully shielded, dead-front submersible cable connections
More information11. CABLE SPECIFICATIONS 5kV, 15kV, AND 35kV RUBBER OR PLASTIC INSULATED CABLE
11. CABLE SPECIFICATIONS 5kV, 15kV, AND 35kV RUBBER OR PLASTIC INSULATED CABLE 11.1 GENERAL Only single conductor cables as described in this section are acceptable for connection to PECO Energy Company
More informationLoadbreak Elbows. 3 Loadbreak Elbows. 200 Amp 5-15 kv Industrial pg Loadbreak Elbows. 200 Amp 25 kv Industrial pg. 254.
3 Loadbreak Elbows 200 Amp 5-15 kv Industrial pg. 252 Loadbreak Elbows 200 Amp 25 kv Industrial pg. 254 Loadbreak Elbows 200 Amp Industrial pg. 255 Loadbreak Elbows Accessories 3 Loadbreak Elbows 3M 200
More information(BUSINESS DAYS) 200A Separable Connectors
DATE October 12, 2018 PAGE 1/11 SUBJECT Cable Accessory Inventory Please refer to the following tables of Cable Accessory inventory which is available for immediate shipment from ABB s Byhalia distribution
More informationSEE PRODUCT GUIDE PG-PC-E FOR SURGE ARRESTER APPLICATIONS THREADED STUD 600 SERIES ELBOW THREADED STUD CONNECTING BUSHING EXTENDER COMPRESSION LUG
ACCESSORIES 600 Series Deadbreak 600 Series deadbreak elbows, straight receptacles, junctions, vault stretchers and accessories are used to connect equipment and cable on primary feeder and network circuits.
More informationMINIMUM DISTRIBUTION SYSTEM CONCEPTS AND APPLICATIONS. Larry Vogt. Manager, Rates
MINIMUM DISTRIBUTION SYSTEM CONCEPTS AND APPLICATIONS Larry Vogt Manager, Rates Minimum Distribution System What is MDS? MDS is an analysis module of the cost-of-service study in which distribution investment
More informationCross Reference Chart CHARDON. PART NUMBER DESCRIPTION Elastimold Cooper Hubbell. Elastimold
Cross Reference Chart CHARDON Elastimold PART NUMBER DESCRIPTION Elastimold Cooper Hubbell 15/25-TB600 15/25 kv, 600A T-Body Connector w/o Test Point K655BLR BT625 625TB 15/25-TB600T 15/25 kv, 600A T-Body
More informationWind Power Solutions. Make Energy Renewable and Reliable!
Wind Power Solutions Make Energy Renewable and Reliable! Reliable Thomas & Betts Products for Clean, Green, Thomas & Betts makes all the products that connect and protect a wind farm and its power distribution
More informationSYSTEM PROTECTION SYSTEM PROTECTION. Underground Electric Distribution Standards I. FUSE COORDINATION
I. FUSE COORDINATION I.1. GENERAL I.1.1. The purpose of protective coordination is to provide isolation of a fault as close to the fault as possible so that a minimum of customers will be affected. The
More informationSECTION 27 - PAD-MOUNTED TRANSFORMERS TABLE OF CONTENTS
CABLE AND CONDUIT ENTRANCE SINGLE-PHASE PAD-MOUNTED TRANSFORMER INSTALLATION 100 KVA AND LARGER (CONCRETE PADS ONLY) 27.05-01 CABLE AND CONDUIT ENTRANCE SINGLE-PHASE PAD-MOUNTED TRANSFORMER INSTALLATION
More informationWisconsin Public Utility Institute. June 28, Minimum Distribution Charges. Larry Vogt. Director, Rates Mississippi Power
Wisconsin Public Utility Institute June 28, 2017 Minimum Distribution Charges Larry Vogt Director, Rates Mississippi Power 1 Costs of Service vs. Cost Recovery Residential Service Example Assuming that
More informationSPECIFICATIONS FOR COMMERCIAL CONSTRUCTION
Roseville Electric SPECIFICATIONS FOR COMMERCIAL CONSTRUCTION REVISED 06/28/18 Commercial Construction Specifications Revision List REVISION Date Page No. Description 03/01/00 4.2-4.3 Changed leveling
More informationTechnical Specification for Pole Mounted Capacitor Rack
Technical Specification for Pole Mounted Rack Page 1 1. Scope and Function a) Pole mounted capacitor racks shall be installed on a distribution feed as an economical means of applying capacitor units to
More informationOutdoor Power Transmission & Distribution
Description: The purpose of the section is to highlight the current applicable UMCP Design Standards and requirements for Outdoor Power Transmission and Distribution, including but not limited to the following:
More informationELECTRICAL MATERIAL BID TABULATION for 2014 CITY OF ST. MARYS WESCO
(1) WATT-HOUR METERS PATH MASTER Item 1 Class 200,V120, Form 12S $59.00 $106.00 Item 2 Class 200, V240, Form 2S $28.00 $90.00 Manufacturer Landis & Gyr Elster (2) WATT-HOUR DEMAND METERS 30 min. demand
More information600 A 35 kv class BT-TAP deadbreak connector
Supersedes 600-55 July 2014 600 A 35 kv class BT-TAP deadbreak connector General Eaton's Cooper Power Systems 600 A 35 kv Class BT-TAP deadbreak connector is used to terminate high-voltage underground
More informationMATERIAL STANDARD ELECTRIC OPERATIONS ORGANIZATION. ****Supercedes BECo Standard E and ComElectric Spec ****
Page 1 of 8 ****Supercedes BECo Standard E2.12-2.14 and ComElectric Spec 7-0895**** THREE-PHASE DEADFRONT PAD-MOUNTED DISTRIBUTION TRANSFORMERS, LOOP & RADIAL FEED DESIGNS 1.0 General Requirements 1.1
More informationSOUTHWEST LOUISIANA ELECTRIC MEMBERSHIP COORPORATION COMMERCIAL SERVICE REQUIREMENTS
SOUTHWEST LOUISIANA ELECTRIC MEMBERSHIP COORPORATION COMMERCIAL SERVICE REQUIREMENTS November 17, 2016 Engineering Service Specifications Table of Contents Commercial Service Requirements SLEMCO Commercial
More informationInstallation Instructions LINK---C
IS---LINK---C Page 1 of 10 Installation Instructions LINK---C DEADBREAK CAM LINK OPERABLE CONNECTOR SYSTEM The is a 600 amp, connector designed to: 1.) provide a fully shielded, fully submersible hot stick
More informationD9-3. No. WIRING DIAGRAM CONNECTIONS FOR UNDERGROUND SELF CONTAINED METERS JRH JED krich95 LINE LINE ABCN SOURCE SOURCE GROUND GROUND STUD STUD SOURCE
SOURCE 20V 240V STUD (PER NEC) A customer supplied and installed teaser wire is required from the neutral lug to a 5th terminal mounted on the left side of the meter block between the line and load terminals.
More information25 kv class fused loadbreak elbow connector
Loadbreak Connectors Catalog Data CA650070EN Supersedes 500-111 July 2012 COOPER POWER SERIES 25 kv class fused loadbreak elbow connector General Eaton combines a fully-shielded and insulated plug-in termination
More informationBRACKETS, MOUNTS & HARDWARE
HIGH VOLTAGE SWITCHGEAR & AUTOMATION EQUIPMENT SECTION 6 Brackets, Mounts & Misc. Hardware CAT. NO: 040930G May, 2008 INERTIA Engineering & Machine Works, INC. Fax: (209) 931-8186 6665 Hardaway Road, Stockton,
More information600 A 25 kv class BT-TAP deadbreak connector
Deadbreak Connectors Catalog Data CA650001EN Supersedes January 2015 600 A 25 kv class BT-TAP deadbreak connector COOPER POWER SERIES General Eaton terminates high-voltage underground cable to transformers,
More information34.00 METERING GENERAL LABELING MULTIPLE METER ENCLOSURES ON A SINGLE PREMISE
4. METERING GENERAL LABELING MULTIPLE METER ENCLOSURES ON A SINGLE PREMISE 4.-4 4. SELF-CONTAINED METERING, SINGE-PHASE INSTALLATION DETAILS /4 VOLT SINGLE-PHASE UNDERGROUND RESIDENTIAL SERVICE AND METER
More informationLoadbreak Apparatus Connectors. 200 A 15 kv Class Loadbreak Elbow Connector with Optional Integral Jacket Seal GENERAL
Loadbreak Apparatus Connectors 200 A 15 kv Class Loadbreak Elbow Connector with Optional Integral Jacket Seal Electrical Apparatus 500-10-7 GENERAL The Cooper Power Systems Loadbreak Elbow Connector is
More informationMEDIUM VOLTAGE
WWW.GENERGYCABLE.COM 800-308-1330 TM MEDIUM VOLTAGE MEDIUM VOLTAGE ASSEMBLIES Type SH Medium Voltage Power Cable Assemblies are designed for heavy-duty MV applications that require temporary or permanent
More information1500 kva Padmount Transformer delta Primary Voltage 208Y/120 Secondary Voltage
1500 kva Padmount Transformer 12470 delta Primary Voltage 208Y/120 Secondary Voltage Cooper Power Systems Proposal Number: BED1096719 Date: January 4, 2010 Revision 00 Item Number: 00001 Item Details Customer
More informationCONSTRUCTION STANDARD ELECTRIC OPERATIONS ORGANIZATION
Page 1 of 11 R1 ****This Standard Supercedes CE Macros MPR1S, MUR1S, MPR3S & MUR3S and portions of BECo Standards CS2.7-1.1, CS2.7-1.5 & CS2.7-1.7**** PRIMARY URD RISER CONSTRUCTION TABLE OF CONTENTS Page
More informationPRODUCT BROCHURE. Elastimold ComboT integral separable connectors
PRODUCT BROCHURE Elastimold ComboT integral separable connectors 2 ELASTIMOLD COMBOT INTEGRAL SEPARABLE CONNECTORS One of the shortest stack heights in the industry works in smaller cabinets and installs
More information600 A 15 kv class T-OP II deadbreak connector
Deadbreak Apparatus Connectors CA650017EN Supersedes 600-12 February 2010 COOPER POWER SERIES 600 A 15 kv class T-OP II deadbreak connector General Eaton terminates high-voltage underground cable to transformers,
More informationJumpers & Load Pickup Tools
Jumpers & Load Pickup Tools Catalog 2300 May 2016 Jumpers & Load Pickup Tools 2300 May 2016 Page 2301 All Chance Insulated Jumpers meet ASTM F 2321 Standard Specification. G4758 15kV 5 5 / 8 " G4765 25kV
More informationyour Green Power WIND POWER SOLUTIONS only Greener
your Green Power WIND POWER SOLUTIONS only Greener WIND POWER SOLUTIONS Thomas & Betts is committed to being your partner in power delivery by leading the industry in innovative wind power solutions and
More informationTable 1. Sample Identification and Comparison Connectors Used in Experiments Sample Conductor Size
Background Information and Purpose Underground cable electrical collection systems have become common in renewable generation system applications (wind farms and solar farms). However, the nature of these
More informationEngineering Service Specifications. Commercial Single-Phase Current Transformer Metering Schemes
Engineering Service Specifications Commercial Single-Phase Current Transformer Metering Schemes Specifications for Commercial Underground Current Transformer Metering Requirements for a Single-Phase Customer
More informationPRODUCT SHEET. Elastimold advanced connection system (shear bolt)
PRODUCT SHEET Elastimold advanced connection system (shear bolt) 2 Elastimold cable accessories The Elastimold advanced connection system - shear bolt is the latest solution to be incorporated into the
More informationJUMPERS & SWITCHING TOOLS
INSULATED JUMPER SETS 368 INSULATED JUMPER SETS FOR 15 KV, 25KV AND 35 KV Used for bypassing work areas when upgrading lines and when making temporary or emergency repairs Continuous-current ratings for
More informationSUBMERSIBLE SECONDARY CONNECTORS SSBC350-4LI. Cond. Range H W L
SUBMERSIBLE SECONDARY CONNECTORS -1- Index TYPE SSBC350-L (Wide-Port Spacing) Rubber Insulated Secondary Connectors SURE-SEAL RUS Approved User friendly wide-port spacing (50% more room for cable training).
More informationElectrical Components
Table of Contents ELECTRICAL COMPONENTS Electrical Components 3 ELECTRICAL COMPONENTS 1 Electrical Cables.... 3-1 - 3-2 Hitch Ball & Grounding Jumpers.... 3-3 Fuses... 3-4 - 3-6 Fuse Packages... 3-7 Cord
More informationGAINESVILLE REGIONAL UTILITIES APPROVED ELECTRIC SYSTEM MATERIALS MANUAL Page 1 ACTIVE MATERIAL INDEXED ALFHABETICALLY. Rev.
Page 1 ACTIVE MATERIAL INDEXED ALFHABETICALLY ANCHOR, DROP-IN FOR 1/2" BOLT 18564-7 A-11.00 11/2/2016 ANCHOR, DROP-IN FOR 3/9" BOLT 18549-3 A-11.00 11/2/2016 ANCHOR, NO-WRENCH: 10" X 96" 01558-6 A-5.00
More informationSECTION 8 - SWITCHES AND PROTECTIVE DEVICES TABLE OF CONTENTS
08.00 GENERAL DISTRIBUTION SURGE ARRESTERS 08.00-0 CUTOUTS AND ARRESTERS GENERAL 08.00-03 08.0 CUTOUTS AND ARRESTERS METAL OXIDE ARRESTERS WITH POLYMER HOUSINGS 08.0-0 APPLICATION OF DIRECT CONNECTED ARRESTERS
More informationWhen power interruptions happen.
When power interruptions happen. We know it s never a good time to have your power go out, so we work all year pruning trees and investing in our system to cut down on problems before they start. Outage
More informationLoadbreak Apparatus Connectors
Loadbreak Apparatus Connectors 200 A 25 kv Class POSI-BREAK Loadbreak Elbow Connector with Optional Integral Jacket Seal* Electrical Apparatus 500-29-7 general The POSI-BREAK Loadbreak Elbow Connector
More informationCABLE TERMINALS
14 00 00 01 Sheet 1 of 1 TABLE OF CONTENTS LOCATION & PLACEMENT OF RISERS ON JOINT USE POLES STANDOFF BRACKET PLACEMENT AND GROUNDING ONE RISER WITH U GUARD, 2, 3, 4, & 5 SPLIT CONDUIT OR SCHEDULE 40 0
More informationPRODUCT BROCHURE. Elastimold advanced connection system (shear bolt)
PRODUCT BROCHURE Elastimold advanced connection system (shear bolt) 2 ELASTIMOLD ADVANCED CONNECTION SYSTEM (SHEAR BOLT) Elastimold cable accessories The Elastimold advanced connection system shear bolt
More informationLine Material Requirements
Invitation to Bid South Hadley Electric Light Line Material Requirements Bid is for a 2 year period. Bidders are to submit two (2) copies of each sealed bid to the Office of the General Manager before
More informationCategory # 1 - Overhead, Primary, & Secondary Conductors
City of Alexandria Bid Proposal # 2214 Open Date - November 27, 2018 Page BF1of BF7 Category # 1 - Overhead, Primary, & Secondary Conductors 1. 2801602110 17,100 LB. CABLE, 477 MCM AAC CONDUCTOR, $ - $
More information200 A 25 kv and 28 kv class loadbreak elbow connector with optional integral jacket seal-canadian Edition
Loadbreak Connector CA650099EN Supersedes 500-28-7C November 2011 COOPER POWER SERIES 200 A 25 kv and 28 kv class loadbreak elbow connector with optional integral jacket seal-canadian Edition General Eaton
More informationTEMPORARY PROTECTIVE GROUNDING EQUIPMENT ACCESSORIES
TEMPORARY PROTECTIVE GROUNDING EQUIPMENT ACCESSORIES TEMPORARY PROTECTIVE GROUNDING EQUIPMENT ACCESSORIES J-2 Grounding Equipment Accessories. www.salisburybyhoneywell.com BALL & SOCKET SYSTEM BALL STUDS
More informationPretest Module 24 Three-phase Service Entrance
Pretest Module 24 Three-phase Service Entrance 1. What is the most widely used three-phase service entrance system? 2. What are the three most common voltage combinations for three-phase, four-wire systems?
More informationAPPENDIX B: LISTS OF APPROVED MATERIALS
APPENDIX B: LISTS OF APPROVED MATERIALS APPENDIX B: LISTS OF APPROVED MATERIALS B1 Street Lighting MAY 2016 APPENDIX B1 STREETLIGHTING MATERIAL LIST 1.0 LIGHTING 1.1 Electrical Handholes CSA Precast concrete
More informationHigh Voltage Joints and Terminations up to 72,5 kv 145 kv
High Voltage Joints and Terminations up to 72,5 kv 145 kv 3M Cold Shrink Termination Kits QT-III and Joint Kits are designed to provide high reliability and save you time and money. They install quickly
More informationCLARK PUBLIC UTILITIES TECHNICAL SPECIFICATIONS THREE-PHASE PADMOUNTED TRANSFORMERS
CLARK PUBLIC UTILITIES TECHNICAL SPECIFICATIONS THREE-PHASE PADMOUNTED TRANSFORMERS Originated 1/85 Revised 6/95 Revised 6/02 Revised 11/05 Revised 4/08 Revised 11/09 Revised 1/12 Revised 11/12 Revised
More information200 A 15 kv class loadbreak elbow connector with optional integral jacket seal
Loadbreak Connectors Catalog Data CA650062EN Supersedes June 2015 COOPER POWER SERIES 200 A 15 kv class loadbreak elbow connector with optional integral jacket seal General Eaton s Cooper Power series
More informationAMENDMENT ELECTRIC SERVICE MANUAL 2014
AMENDMENT (Pages 20,43,50,72,74,,76,78,83,86,99) ELECTRIC SERVICE MANUAL 2014 Effective April 1, 2015 18-7 6.0 SERVICE AND SERVICE ENTRANCES (General), Continued Conductor Sizing It is recommended that
More informationSYSTEM PROTECTION - PLATING
INTRODUCTION 1. Plates F1 thru F10 supply only the material required for one-phase. Therefore, for threephase construction, you will be required to call for the specified plate three times at that station.
More informationInstallation Instructions 15/25/35kV, 600/900 AMPERE
Installation Instructions 15/25/35kV, 600/900 AMPERE Two---, Three--- and Four---Point Deadbreak Junctions IS---600/900A J2,J3,J4 Page 1 of 7 CONTENTS: The contents always include: 1---Deadbreak Junction,
More informationcopper stud. If a 900 A rating is desired, specify a C as the 8th digit when determining your part number (See Table 3, page 3.)
Molded Rub ber Products 600 A 35 kv Class Separable Splices Electrical Ap pa ra tus 700-31 General Cooper Power Systems 600 A, 35 kv Class Deadbreak Separable Splices are used to splice two, three or four
More informationA. Three-phase, oil filled self-cooled, padmounted transformers are installed outdoors on pads in the EWEB distribution system.
1. APPLICATION A. Three-phase, oil filled self-cooled, padmounted transformers are installed outdoors on pads in the EWEB distribution system. 2. REFERENCE STANDARDS A. The transformers supplied shall
More informationItem Code Description Unit Qty Total
UNDP ELECTRICITY SECTOR NORTHERN GOVERNORATES Phase XI Item Code Description Unit Qty Total 04-02-00001 Service Pole - 6m, 75mm dia GS Pipe 11250 04-02-00002 9m Tubular Steel Poles complete with all Accessories
More information200 A 15 kv class loadbreak elbow connector with optional integral jacket seal-canadian Edition
Loadbreak Connectors Catalog Data CA650063EN Supersedes 500-10-7C November 2011 COOPER POWER SERIES 200 A 15 kv class loadbreak elbow connector with optional integral jacket seal-canadian Edition General
More information200 A 25 and 28 kv class POSI-BREAK loadbreak elbow connector with optional integral jacket seal-canadian Edition
Loadbreak Connectors CA650101EN Supersedes 500-29-7C November 2011 COOPER POWER SERIES 200 A 25 and 28 kv class POSI-BREAK loadbreak elbow connector with optional integral jacket seal-canadian Edition
More informationMCM CABLE 3/15/2010
00 000 MCM CABLE //00 C UEE Elbow Enclosure - Deadend C UEE Elbow Enclosure - Feed-Through C UP 000 MCM Cable iser ~ UP 000MCM Power Cable iser Grounding Detail N UP 000 MCM Cable iser with Ø Switch N
More information15 kv Class Fused Loadbreak Elbow Connector with Interchangeable Fuse Capability
15 kv Class Fused Loadbreak Elbow Connector with Interchangeable Fuse Capability Application The Chardon 15 kv Class Fused Loadbreak Elbow Connector combines a fullyshielded and insulated loadbreak elbow
More informationELASTIMOLD UNDERGROUND CABLE ACCESSORIES
ELASTIMOLD UNDERGROUND CABLE ACCESSORIES ELASTIMOLD FEATURES AND BENEFITS The Elastimold brand is recognised as the leading producer of premoulded cable accessory components worldwide. Utilising specially
More informationWILDLIFE PROTECTION
05 00 00 01 TABLE OF CONTENTS GENERAL INFORMATION INSTALLATION OF CRITTER LINE GUARDS INSTALLATION OF TANK MOUNTED LIGHTNING ARRESTER BRACKET GUARDS 25KV & BELOW EXISTING STRUCTURE MODIFICATION 05 00 00
More informationCustomer Requirements Downtown Secondary Network Service
Application This standard describes the limitations and requirements for receiving service from the Tacoma Power secondary network system within the City of Tacoma downtown core area. In This Standard
More information1VAL2401-SG Rev D. Spare parts list for Outdoor Products Reclosers, breakers, & padmount switches
1VAL2401-SG Rev D Spare parts list for Outdoor Products Reclosers, breakers, & padmount switches Reclosers GridShield recloser 12A00736H05 Actuator assist capacitor Single-phase upgrade 15 KV, 800 A, 12.5
More information3.1 Overview of ATCO Electric s URD System Design
Page: 3-1 3.0 URD DESIGN GUIDELINES 3.1 Overview of ATCO Electric s URD System Design The power supply to all single lot underground residential services is through front lot service. Single phase transformers
More informationINSTALLATION PRODUCTION TESTS
Deadbreak Apparatus Connectors 600 A 15/25 kv Class Bol-T Deadbreak Connector Electrical Apparatus 600-10 GENERAL The Cooper Power Systems 600 A, 15/25 kv Class Bol-T Deadbreak Connector is used to terminate
More informationGENERAL INFORMATION POLE MOUNT TRANSFORMER SINGLE PHASE PAD MOUNT TRANSFORMER SINGLE PHASE POLE MOUNT TRANSFORMER THREE PHASE 17
GENERAL INFORMATION SECTION GUIDE SECTION 10 PAGE 1 DESCRIPTION SECTION NUMBER GENERAL INFORMATION... 10 POLE MOUNT TRANSFORMER SINGLE PHASE... 15 PAD MOUNT TRANSFORMER SINGLE PHASE..... 16 POLE MOUNT
More information35-kV Safefront 200 Amp SuperWell Primary Capacitor Station Pad-Mounted Outdoor
Page 1 2016 EPM-PCS-35-320P-R2/ESW-GCM6-2S-SA Three Phase Two Ways per Phase 200 Amp 35 kv Class Eaton's CPS LRTPs 35 kv Elliott Air-Insulated SuperWell Bushings 21.1/36.6 kv Grounded Wye Max Design, 150
More information600 A 35 kv class separable splices
Splices Catalog Data CA650050EN Supersedes 700-31 March 2009 COOPER POWER SERIES General Eaton s Cooper Power series 600 A, 35 kv Class deadbreak separable splices are used to splice two, three or four
More informationADDENDUM No. 1 Prospective Bidders
Page 1 of 1 Attachment to Addendum # 1 Revised Itemized Bid ADDENDUM No. 1 TO: Prospective Bidders FROM: Gregory Tate, Construction Contracts Administrator DATE: January 24, 2019 PROJECT: Traffic Signal
More informationUNDERGROUND SERVICE ENTRANCE LOCATION. No meter base or entrance should be installed before an KREMC engineer has checked the proposed location.
UNDERGROUND SERVICE No meter base or entrance should be installed before an KREMC engineer has checked the proposed location. Entrance cabinet must be directly through wall or directly under meter in basement.
More informationSpecification Pad-Mounted Capacitor Bank with Dual Fusing Integral Load-Interrupter on Line-Side Fuse Mountings
Page 1 Specification Pad-Mounted Capacitor Bank with Dual Fusing Integral Load-Interrupter on Line-Side Fuse Mountings I. General This specification covers the design requirements for a pad-mounted capacitor
More informationRESIDENTIAL SUBDIVISION SERVICE REQUIREMENTS SECTION VI RESIDENTIAL SUBDIVISION SERVICE REQUIREMENTS
SECTION VI SERVICE REQUIREMENTS This section discusses the requirements for establishing electric service to new residential subdivisions in Palo Alto. Subdivisions are normally constructed on dedicated
More informationCATALOG. Underground cable accessories
CATALOG Underground cable accessories 2 ELASTIMOLD UNDERGROUND CABLE ACCESSORIES Choose Thomas & Betts and connect to the power you need For over 100 years, Thomas & Betts has successfully applied innovative
More informationUnderground Primary & Secondary. Cable Installation
TITLE: Technical Specification RECOMMENDED: M. Lamoureux, B.Hazlett NO: 1 REV: APPROVED: C. Malone OF GCS0004 REV. DATE: 2017-04-13 19 4 Underground Primary & Secondary Cable Installation For Hydro Ottawa
More informationDeadbreak Apparatus. connectors. 600 A 15/25 kv Class GENERAL
Deadbreak Apparatus Connectors 600 A 15/25 kv Class BOL-T Deadbreak Connector Electrical Apparatus 600-30 GENERAL The Cooper Power Systems 600 A, 15/25 kv Class BOL-T Deadbreak Connector is used to terminate
More informationUG FEEDING OH UG FEEDING OH. Electric Distribution Standards I. INTRODUCTION
I. INTRODUCTION Electric Distribution Standards Design, Construction & Material Standards formed a special committee to establish some basic design guidelines for construction alternatives to be used for
More informationELB ES. Product Installation Instructions
ELB-25-210-ES 200A 25kV Class Loadbreak Elbow with Integral Jacket Seal for Copper Tape (CT) and Jacketed Concentric Neutral (JCN) cables Product Installation Instructions Safety Instructions When installing
More informationSPECIFICATIONS FOR NEW UNDERGROUND RESIDENTIAL DISTRIBUTION SYSTEMS
Date: 05-MAY-2017 Revision: 7.3 Supersedes: 7.2 SPECIFICATIONS FOR NEW UNDERGROUND RESIDENTIAL DISTRIBUTION SYSTEMS APPENDIX E MATERIAL SPECIFICATIONS Drawing DESCRIPTION Number E.1 PRIMARY UNDERGROUND
More informationJACKSON ELECTRIC COOP METER LOOP CONSTRUCTION SPECIFICATIONS JUNE 2018
JACKSON ELECTRIC COOP METER LOOP CONSTRUCTION SPECIFICATIONS JUNE 2018 GANADO OFFICE PHYSICAL ADDRESS: 8925 State Highway 111 E Ganado, TX 77962 Phone: (361)771-4400 BAY CITY OFFICE PHYSICAL ADDRESS: 100
More informationTRANSMITTAL LETTER. As Builts Change Order Contract Copy of Letter Insurance. For approval Approved as submitted Resubmit copies for approval
Redwood City Electric, Inc. TRANSMITTAL LETTER To: Transworld Construction, Inc. 1178 Folsom Street San Francisco, CA 94103 Date: 05/31/12 Job #: 9340 Regarding: SFO DATA CENTER Attn: Rob Acero We are
More informationSpecifier's Guide COOPER POWER. Line installation and protective equipment master catalog 5 kv - 35 kv electrical distribution systems SERIES
Eaton's Cooper Power series products COOPER POWER SERIES Specifier's Guide Line installation and protective equipment master catalog 5 kv - electrical distribution systems Education and Training OCP CEU-Accredited
More informationPRODUCTS FOR THE RAIL AND UTILITY INDUSTRY
PRODUCTS FOR THE RAIL AND UTILITY INDUSTRY connectorproducts.com 1300 John Tipton Blvd. Pennsauken, NJ 08110 Phone: 856.829.9190 Fax: 856.829.9195 Catalog IX.1 American Design American Made Our success
More informationPolymer Insulators A Better Solution
Polymer Insulators A Better Solution October 2016 LET S CONNECT POLYMER INSULATORS Design derived from PLP s many years of worldwide experience and tested to adhere to ANSI C29.5 and ANSI 29.6 insulator
More information7 Single Family Service
7 Single Family Service 7. General The location of the service entrance on the Customer s premises is an important consideration. For clearance and location information see section 5 (Clearances). Consult
More informationTests are conducted in accordance with IEEE Standard 386. ac 60 Hz 1 Minute Withstand 50
Deadbreak Apparatus Connectors 600 A 35 kv Class Bol-T Deadbreak Connector Electrical Apparatus 600-50 General The Cooper Power Systems 600 A, 35 kv Class Bol-T Deadbreak Connector is used to terminate
More informationUNDERGROUND SERVICE ENTRANCE LOCATION. No meter base or entrance should be installed before an KREMC engineer has checked the proposed location.
UNDERGROUND SERVICE No meter base or entrance should be installed before an KREMC engineer has checked the proposed location. Entrance cabinet must be directly through wall or directly under meter in basement.
More informationNEW Solutions for Underground System Growth
NEW Solutions for Underground System Growth Cooper s Single-Phase Voltage Regulator Improved Power Quality More Economical Improved System Reliability Increased Safety Better Aesthetics Lower Maintenance
More informationSingle-Phase Step Voltage Regulators
Voltage Regulators Catalog Data CA225001EN Supersedes March 2017 COOPER POWER SERIES Single-Phase Step Voltage Regulators Contents GENERAL....2 STANDARD FEATURES....4 OPTIONAL ACCESSORIES...4 ARRESTERS....4
More informationFor Conduit Inspections
Underground Conduit Standards - Table of Content 5/8/2017 Section S22 Underground Conduit Standard Index: Description: 00 Table of Content 01 General Notes 02 Definition of Terms 03 Primary Riser Conduit
More informationGAINESVILLE REGIONAL UTILITIES APPROVED ELECTRIC SYSTEM MATERIALS MANUAL Page 1 ACTIVE MATERIAL INDEXED ALFHABETICALLY. Rev.
Page 1 ACTIVE MATERIAL INDEXED ALFHABETICALLY ANCHOR, DROP-IN FOR 1/2" BOLT 18564-7 A-11.00 9/12/2011 ANCHOR, DROP-IN FOR 3/9" BOLT 18549-3 A-11.00 9/12/2011 ANCHOR, NO-WRENCH: 10" X 96" 01558-6 A-5.00
More informationSAMPLE. Job Name: Anywhere Water District Construction of Reservoir Suggest'd Equipment Rent Total. Suggest'd Material.
Job Name: Anywhere Water District Construction of Reservoir 1500 Anywhere Water District Construction of Reservoir 1500 Electrical Contractor Sub Bid Qty #Elect Hours Unit Underground Conduit Work $60/hr
More informationHigh Voltage Copper, Smooth Aluminum Shield/Sheath
High Voltage Copper, Smooth Aluminum Shield/Sheath XLPE Insulation, HDPE Jacket, 69 kv - 138 kv Features True triple vertical extrusion system for optimum insulation concentricity, and excellent electric
More information1100 OVERHEAD TRANSFORMERS
00 OVEHEAD TANSFOMES //00 ~ F Pole Type - Transformer Fuse Schedule ~ T Transformer Field Stenciling Code ~ TA Transformer Coding for Material Mgmt System C T,TH Pole Mounted Transformer and Cutout on
More informationSingle-phase step voltage regulators
Voltage Regulators Catalog Data CA225001EN Supersedes 225-10 February 2014 COOPER POWER SERIES General Eaton's Cooper Power series VR-32 singlephase step voltage regulators are tap-changing autotransformers.
More informationGrounding equipment COOPER POWER SERIES. Temporary Connections CA325004EN. Contents
Temporary Connections CA325004EN Supersedes November 2016 Grounding equipment COOPER POWER SERIES Contents Description Page Grounding elbow products... 2 Grounding elbow and kit product ratings... 5 200
More information