1 Wisconsin Public Utility Institute June 28, 2017 Minimum Distribution Charges Larry Vogt Director, Rates Mississippi Power 1

2 Costs of Service vs. Cost Recovery Residential Service Example Assuming that all defined customerrelated costs are recovered through the Customer Charge. 2

3 Principal Cost-of-Service Study Cost Components The classification step of the cost-of-service study assigns all of the functionalized cost elements to the fundamental cost-causation components of Energy, Demand, and Customer. Energy-related costs variable costs which are dependent on kwh energy requirements. Demand-related costs fixed costs which are dependent on kw load requirements. Customer-related costs fixed costs which are independent of load or energy requirements. 3

4 Classification of Functional Costs Fuel Energy Costs: VARIABLE Demand Costs: FIXED Minimum Distribution System (MDS) Customer Costs: FIXED 4

5 Distribution System Lines and Facilities Costs FERC Description 360 Land and Land Rights 361 Structures 362 Station Equipment S MCM ACSR SUB M R N.C. 363 Storage Battery Equipment 364 Poles, Towers & Fixtures 365 OH Conductors & Devices Switches 4/0 CU NO. 2 AL C/N 75 N.C. N.C. 1,500 ckvar Reclosers & Sectionalizers 366 UG Conduit 367 UG Conductors & Devices Line Transformers Regulators Capacitors Cutouts 15 1/0 CU Arresters 369 Services 370 Meters N.O. 373 Street Lighting 5

6 Distribution System O&M Costs FERC Description Operation Maintenance Distribution Expenses (Excluding Substations) Customer Account Expenses - Operation Customer Assistance Expenses Operation Sales Expenses Operation Administrative and General (A&G) Expenses (Allocated portion) Operation 935 Maintenance 6

7 Cumulative 1-Phase Residential Customer Cost Components Revenue Requirement per Customer per Month MDS Customer Costs Minimal Customer Costs 7

8 Minimum Distribution System What is MDS? MDS is an analysis module of the cost-of-service study in which primary and secondary voltage distribution system investment and O&M costs are classified between demandrelated and customer-related cost components. Why is MDS important? MDS quantifies those fixed costs that are independent of load or energy usage and thus provides a cost-justification basis for inclusion in the Customer Charge portion of the rate structure. 8

9 The Access Function Of The Distribution System All primary and secondary voltage customers are connected to a distribution voltage source, i.e., a local substation. SUB There is a physical path which brings voltage to the customer s premise. Maintaining the voltage path ensures customer access to electrical power. 9

10 The Capacity Function Of The Distribution System Primary and secondary distribution system facilities and lines must be sized to adequately handle the customers demand for power. Electric service facilities are rated in terms of kva capacity (conductors rated in terms of ampacity). Customer Load Feeder Load 10

11 Objective of the Minimum Distribution System Analysis To assess each device utilized in the distribution system in terms of its mission in order to determine if its function is: Dependent on kw load requirements and therefore demand related, or Independent of kw load requirements and therefore customer related. 11

12 Customer or Demand? 12

13 Capacitor-Based Voltage Control MW SUB FEEDER 132 V +10% 120 V 108 V 10% TIME DISTANCE 13

14 Customer or Demand? 14

15 Protection Scheme Temporary Fault Condition SUB CB R 15

16 Protection Scheme Permanent Fault Condition SUB CB R 16

17 Protection Scheme Permanent Fault Condition No Load SUB CB R 17

18 Customer or Demand? 18

19 Classification of Distribution Plant for the Cost-of-Service Demand Customer Distribution Substations X Primary Lines* X X Line Transformers* X X Secondary Lines* X X Other Line Equipment* X X Service Lines Meters X X * Minimum Distribution System facilities. 19

20 Zero-Intercept Methodology Applied to: Line Transformers Conductors Poles THE Y-AXIS INTERCEPT UNIT COSTS IS THE UNIT COST OF ZERO CAPACITY COST OF A STANDARD SIZE UNIT CAPACITY 20

21 Line Transformers 21

22 Zero-Intercept Example Single-Phase Overhead Transformers 1. ZERO-INTERCEPT: $ /transformer Based on various kva sizes of 7.2 kv - 120/240 V, single bushing, polemount transformers 2. TOTAL NUMBER OF OVERHEAD TRANSFORMERS: 98,278 CUSTOMER COMPONENT = $ ,728 = $45,807, TOTAL OVERHEAD TRANSFORMER COST: $109,960,813 DEMAND COMPONENT = $109,960,813 - $45,807,307 = $64,153,506 CUSTOMER COMPONENT = 41.7% DEMAND COMPONENT = 58.3% 22

23 Primary and Secondary Conductors and Poles PRIMARY NEUTRAL SECONDARY 23

24 UNDERGROUND PRIMARY CABLE CONCENTRIC NEUTRAL CONDUCTOR 24

25 CONDUIT FOR UNDERGROUND CABLES RIGID PVC FLEXIBLE 25

26 Distribution Poles Types Of Materials 100% 90% 80% 70% 60% 50% 40% 30% 20% 10% 1.0% 0.9% 0.8% 0.7% 0.6% 0.5% 0.4% 0.3% 0.2% 0.1% 0.0% ALUMINUM CONCRETE FIBERGLASS STEEL 0% ALUMINUM CONCRETE FIBERGLASS STEEL WOOD 26

27 Pole Heights Relative Frequency Distribution 40% 35% 30% 25% 20% 15% 10% 5% 0% 30' 35' 40' 45' 50' 55' 60' 65' 70' 75' 80' 85' 90' 95' POLE HEIGHTS 27

28 Clearance Requirements Poles lines must be designed to ensure proper safety clearances, such as specified in the National Electric Safety Code (NESC), Section 23. The NESC provides specific minimum clearances of power lines located over: Roadways, parking lots, driveways, pedestrian areas, railroad track rails, water ways, etc. Other electric conductors and services, trolley/electric train cables, communications cables, etc. 28

29 Pole Line Grading IMPROPER GRADING: POLES ALL HAVE THE SAME HEIGHT PROPER GRADING: POLES WITH VARYING HEIGHTS 29

30 Distribution Pole Classification Conclusion On Pole Height Pole height requirements are mainly a function of clearances and line grading, which are related to safety and mechanical design. In some situations, a pole height may need to be increased (e.g., from a 40 to a 45 ) to accommodate some facilities. Overall, pole height is not a predominant function of load. 30

31 Pole Class 31

32 Standard Pole Classes Example: 35 Wood Pole No No No No No No No MINIMUM CIRCUMFERENCE OF SOUTHERN YELLOW PINE POLES (@ GROUND LINE) 32

33 Pole Class Requirements Based On Transformer Capacity 0 TRANSFORMER kva POLE CLASS TRANSFORMER 2 TRANSFORMERS 3 TRANSFORMERS 33

34 Distribution Pole Classification Conclusion On Pole Class The physical sizes and weights of line transformers and conductors are related to their current carrying capabilities. Pole class must be increased in order to carry heavy mechanical loads caused by large line transformers and conductors. Overall, pole class is a predominant function of load. 34

35 Example MDS Analysis Results Poles, Transformers, and Conductors Customer Demand Poles Wood 66.4% 33.6% Concrete 47.3% 52.7% Steel 57.5% 42.5% Transformers 1Φ OH* 41.7% 58.3% 1Φ UG** 61.5% 38.5% 3Φ UG** 34.2% 65.8% Customer Demand Conductors Primary Bare ACSR OH 21.0% 79.0% 15 kv CN UG* 57.4% 42.6% Secondary WP AL OH 38.4% 61.6% Duplex OH 31.4% 68.6% 1-Conductor UG* 60.7% 39.3% * Basis for classifying transformer vaults ** Basis for classifying transformer pads * Basis for classifying conduit 35

36 Example MDS Analysis Results Distribution Line Devices Primary Secondary Customer Demand Customer Demand Regulators & Capacitors 100% Reclosers and Sectionalizers 100% Cutouts & Arresters Line Transformers (OH) 41.7% 58.3% Regulators & Capacitors 100% Reclosers & Sectionalizers 100% Line Protection 100% Bypass Switches Regulators 100% Reclosers & Sectionalizers 100% OH Line Switches* 21.0% 79.0% UG Line Switches* 57.4% 42.6% * Based on conductors 36

37 Example Cost-of-Service Results For Three Low Voltage Customer Classes 37

38 Q&A Larry Vogt 38

39 Appendix Materials 39

40 Weighted Linear Regression For Distribution Line Transformers m N nxy nxny 2 N nx nx 2 SLOPE N = Total number of all transformers of a given type, e.g., 59, kv - 120/240 V, single-bushing, polemount units n = Number of a given size transformer, e.g., 9, kva b y INTERCEPT ny m N nx N X = Transformer size in kva, e.g., 5, 7.5, 10, 15, etc. Y = Transformer unit cost in $ per unit, e.g., $ (cost of a 15 kva unit) 40

41 Zero-Intercept Analysis The Problem With Vintage Costs $2,000 $1,800 $1,600 $1,400 Analysis of Pad-Mount Line Transformers Based on Booked Installed Costs Unit Cost $1,200 $1,000 $800 $600 $400 $200 3Φ 1Φ $ kva 41

42 Zero-Intercept Analysis Utilizing Current Costs $15,000 Analysis of Pad-Mount Line Transformers Based on Rebuild Costs $13,500 $12,000 3Φ Unit Cost $10,500 $9,000 $7,500 $6,000 $4,500 $3,000 $1,500 1Φ $ kva 42

43 Zero-Intercept Example Primary Overhead Conductor 1. ZERO-INTERCEPT: $0.396/ft Based on various MCM sizes of bare ACSR conductors 2. TOTAL LENGTH OF PRIMARY CONDUCTORS: 15,708,000 ft PRIMARY CIRCUIT LENGTH: 15,708,000 2 = 31,416,000 ft CUSTOMER COMPONENT = $ ,898,000* = $11,827,081 * Minimum Distribution System Length 3. TOTAL PRIMARY CONDUCTOR COST: $56,416,253 DEMAND COMPONENT = $56,416,253 - $11,827,081 = $44,589,172 CUSTOMER COMPONENT = 21.0% DEMAND COMPONENT = 79.0% 43

44 Determination Of Overhead Circuit Lengths For The MDS TOTAL POLE MILES PRIMARY SUB PRIMARY NEUTRAL COMMON NEUTRAL SECONDARY NEUTRAL SECONDARY UNDERBUILD SECONDARY TAPS 44

45 Weighted Linear Regression For Distribution Conductors m N nxy nxny 2 N nx nx 2 SLOPE N = Total feet of all conductors of a given type, e.g., 47,557,568 ft of ACSR conductors n = Number of feet of a given size conductor, e.g., 26,194,939 ft of #2 ACSR b y INTERCEPT ny m N nx N X = Conductor size in MCM (a #2 wire is MCM), e.g., 26.24, 41.74, 52.62, 66.36, etc. Y = Conductor unit cost in $ per feet, e.g., $0.659/ft (cost of a #2 ACSR conductor) 45

46 Pole Capacity Poles have no electrical capacity component, but they do have a mechanical capacity (strength) component that can be viewed as a proxy for electrical loading. Pole class (or circumference) can represent loading capability for wood poles, but it does not work for steel or concrete poles since different classes can have the same physical dimensions. Ground line moment capacities do differ by class for all poles. Example: 35 5-C Pole Transverse Wind Load of 1,200 lb GLMC = 33,000 ft-lbs = 33 kips 46

47 Weighted Linear Regression For Distribution Poles m N nxy nxny 2 N nx nx 2 SLOPE N = Total feet of all poles of a given type, e.g., 55,642 ft of 40 ft wood poles n = Number of feet of a given size pole based on its GLMC, e.g., 21,137 ft of kilopounds (kips) poles b y INTERCEPT ny m N nx N X = Ground Line Moment Capacity in kips, e.g., 48.0, 60.8, 76.8, 96.0, etc. Y = Pole unit cost in $ per feet, e.g., $12.05/ft (cost of a 76.8 kips pole) 47

48 Zero-Intercept Example Wood Poles 1. ZERO-INTERCEPT: $7.883/ft Based on various kip ratings of 40 southern pine poles 2. TOTAL LINEAR FEET OF WOOD POLES: 5,579,390 ft CUSTOMER COMPONENT = $ ,579,390 = $43,982, TOTAL WOOD POLE COST: $66,254,744 DEMAND COMPONENT = $66,254,744 - $43,982,773 = $22,271,971 CUSTOMER COMPONENT = 66.4% DEMAND COMPONENT = 33.6% 48

49 Differentiated Cost Allocation Based on Voltage Magnitude & Phase 49

50 3-Phase vs. 1-Phase Customers Cost-of-Service Weighted Allocators CUSTOMER VOLTAGE CLASS 1Φ LV 3Φ LV 1Φ HV 3Φ HV 1Φ OH Line Transformers L 1 L 3 3 Services: 1Φ Lines L 1 3Φ Lines L 3 Meters: Watt-hour (non-demand) LN 1 1Φ Demand LD 1 H 1 3Φ Demand L 3 H 3 LV CT LD 1 L 3 3 LV VT LD 1 L 3 3 HV CT H 1 H 3 3 HV VT H 1 H 3 3 L 1 = # of 1Φ LV customers (LN 1 +LD 1 ); L 3 = # of 3Φ LV customers H 1 = # of 1Φ HV customers; H 3 = # of 3Φ HV customers 50

MINIMUM DISTRIBUTION SYSTEM CONCEPTS AND APPLICATIONS. Larry Vogt. Manager, Rates

MINIMUM DISTRIBUTION SYSTEM CONCEPTS AND APPLICATIONS. Larry Vogt. Manager, Rates MINIMUM DISTRIBUTION SYSTEM CONCEPTS AND APPLICATIONS Larry Vogt Manager, Rates Minimum Distribution System What is MDS? MDS is an analysis module of the cost-of-service study in which distribution investment

More information

TEN YEAR PLANNING GUIDE SHASTA LAKE ELECTRIC UTILITY

TEN YEAR PLANNING GUIDE SHASTA LAKE ELECTRIC UTILITY TEN YEAR PLANNING GUIDE SHASTA LAKE ELECTRIC UTILITY 2011-2020 P+ PowerPlus Engineering A Department of STAR Energy Services, LLC TEN YEAR PLANNING GUIDE 2011-2020 SHASTA LAKE ELECTRIC UTILITY CITY OF

More information

9. Non-Residential Services (Commercial, Industrial, and Agricultural)

9. Non-Residential Services (Commercial, Industrial, and Agricultural) Section 9 2016 Electric Service Requirements, 3rd Edition Section 9 Non-Residential Services Directory Page 9.1 General Requirements 68 9.2 Direct-Connect Metering, Single Installations 69 9.3 Direct-Connect

More information

BUSINESS PROCEDURE. January 1, 2015

BUSINESS PROCEDURE. January 1, 2015 PURPOSE To provide uniform charges and standard estimating unit charges for electric supply and service to all classes of customers as required and supported by other NB policies. SCOPE This pricing policy

More information

Methodology of Cost Allocation

Methodology of Cost Allocation Methodology of Cost Allocation Robin Kliethermes May 17, 2013 1 Purpose of Cost Allocation Determine whether each class of customers is providing the utility with a reasonable level of revenue necessary

More information

AMENDMENT ELECTRIC SERVICE MANUAL 2014

AMENDMENT ELECTRIC SERVICE MANUAL 2014 AMENDMENT (Pages 20,43,50,72,74,,76,78,83,86,99) ELECTRIC SERVICE MANUAL 2014 Effective April 1, 2015 18-7 6.0 SERVICE AND SERVICE ENTRANCES (General), Continued Conductor Sizing It is recommended that

More information

34.00 METERING GENERAL LABELING MULTIPLE METER ENCLOSURES ON A SINGLE PREMISE

34.00 METERING GENERAL LABELING MULTIPLE METER ENCLOSURES ON A SINGLE PREMISE 4. METERING GENERAL LABELING MULTIPLE METER ENCLOSURES ON A SINGLE PREMISE 4.-4 4. SELF-CONTAINED METERING, SINGE-PHASE INSTALLATION DETAILS /4 VOLT SINGLE-PHASE UNDERGROUND RESIDENTIAL SERVICE AND METER

More information

FROM B.C. HYDRO ENCLOSURE (SEE NOTE 4) RIGID CONDUITS (SEE NOTE 8) ALTERNATIVE TO LOAD BARRIER (SEE NOTE 7) SERVICE ENTRANCE ENCLOSURE

FROM B.C. HYDRO ENCLOSURE (SEE NOTE 4) RIGID CONDUITS (SEE NOTE 8) ALTERNATIVE TO LOAD BARRIER (SEE NOTE 7) SERVICE ENTRANCE ENCLOSURE FROM B.C. HYDRO FOR OVERHEAD INSTALLATION ONLY DUCT SEAL (SEE NOTE 8) PULL BOX (SEE NOTE 5) PULL BOX (SEE NOTE 5) FROM B.C. HYDRO 7- REVISED NOTES & TABLES ON PAGES,3,4,5,.MARCH AJ - GENERAL REV.MA 08

More information

WPS SERVICE MANUAL. Section 7 Clearances. 7-1 Basic Electric Clearances - Services Miscellaneous Clearances Antenna Clearances...

WPS SERVICE MANUAL. Section 7 Clearances. 7-1 Basic Electric Clearances - Services Miscellaneous Clearances Antenna Clearances... Revised 03/2016 Section 7 CLEARANCES Page 1 of 9 Section 7 Clearances 7-1 Basic Electric Clearances - Services... 2 7-2 Miscellaneous Clearances... 7 7-3 Antenna Clearances... 9 Revised 03/2016 Section

More information

10 Commercial, Industrial, Agricultural Services

10 Commercial, Industrial, Agricultural Services 10 Commercial, Industrial, Agricultural Services This section describes the Power Company requirements for commercial, industrial, and agricultural services. This section covers single phase and three

More information

SYSTEM PROTECTION SYSTEM PROTECTION. Underground Electric Distribution Standards I. FUSE COORDINATION

SYSTEM PROTECTION SYSTEM PROTECTION. Underground Electric Distribution Standards I. FUSE COORDINATION I. FUSE COORDINATION I.1. GENERAL I.1.1. The purpose of protective coordination is to provide isolation of a fault as close to the fault as possible so that a minimum of customers will be affected. The

More information

Max value Max life Range from. ($000) (Years) Pole Type

Max value Max life Range from. ($000) (Years) Pole Type Draft Handbook Vector Asset Description 1 Unit Maximum Maximum Life Max value Max life Max Asset Life Max Asset Life Range from Submitters Max Asset Life ($000) SUBTRANSMISSION Concrete Wood Concrete Wood

More information

Transmission & Distribution Glossary of Electrical Terms

Transmission & Distribution Glossary of Electrical Terms Transmission & Distribution Glossary of Electrical s Breaker Panel Bushing Circuit Circuit Breaker Conductor Conduit Consumption Current Distribution Electricity (Static vs. Current) Electron Feeder The

More information

Jefferson County PUD Pole Attachment Rate Model Assumptions Exhibit A

Jefferson County PUD Pole Attachment Rate Model Assumptions Exhibit A Jefferson County PUD Assumptions Exhibit A Utility: Jefferson PUD Date Prepared: December 3, 2014 Prepared By: EES Consulting Assumptions Expense Allocation Basis FCC Telecom Rate APPA Rate Net Plant Gross

More information

AGRICULTURAL UNDERGROUND SERVICE 500 HP OR LESS

AGRICULTURAL UNDERGROUND SERVICE 500 HP OR LESS Prepared by: ABB1 AGRICULTURAL UNDERGROUND SERVICE 500 HP OR LESS 05619 Asset Type: Electric Metering Function: Design and Construction Issued by: Lisseth Villareal (LDV2) Date: 07-31-15 Rev. #10: This

More information

TABLE OF CONTENTS. Important Notices Underground Plant Protection Information. Commercial/Industrial Information Sheet

TABLE OF CONTENTS. Important Notices Underground Plant Protection Information. Commercial/Industrial Information Sheet DRAWING NUMBER INTRODUCTORY INFORMATION Important Notices Underground Plant Protection Information Code Clearances Commercial/Industrial Information Sheet Work Management Customer Projects Engineering

More information

OEB's Appendix 2-B: Fixed Asset Continuity Schedule

OEB's Appendix 2-B: Fixed Asset Continuity Schedule Page 1 of 11 OEB's Appendix 2-B: Fixed Asset Continuity Schedule Table 1: Fixed Asset Continuity Schedule - Actuals 2008 N/A 1805 Land NA 2.2 - (0.0) 2.2 0 - - - - 2.2 CEC 1806 Land Rights 2.0% 1.6 0.1-1.7

More information

Customer Requirements Clearance Requirements for Overhead Joint Utility Construction

Customer Requirements Clearance Requirements for Overhead Joint Utility Construction Application This standard establishes the clearances that are required on utility pole structures between electrical supply facilities owned and operated by Tacoma Power and communication facilities owned

More information

WPS SERVICE MANUAL. Section Amp and Smaller - Common

WPS SERVICE MANUAL. Section Amp and Smaller - Common Revised 01/2017 Section 2 200 AMP AND SMALLER - COMMON Page 1 of 17 Section 2 200 Amp and Smaller - Common 2-0 General Metering Requirements... 2 2-1 Basic Calculations... 4 2-2 100-200 Amp Single-Phase

More information

Transmission and Distribution Substation Projects. Operating Company: Entergy Gulf States - Texas. Customer: PID # 202

Transmission and Distribution Substation Projects. Operating Company: Entergy Gulf States - Texas. Customer: PID # 202 Transmission and Distribution Substation Projects Operating Company: Entergy Gulf States - Texas Customer: PID # 202 Funding Project Number: F4PPGS0386 Facility Study for PID # 202: Study for 146 MW Revision

More information

SECTION 300 OVERHEAD SERVICE

SECTION 300 OVERHEAD SERVICE SECTION 300 OVERHEAD SERVICE 300.01 General Company provides, installs, and maintains service drop to point of delivery approved by Company. Customer provides point of attachment which is acceptable to

More information

SPECIFICATIONS FOR COMMERCIAL CONSTRUCTION

SPECIFICATIONS FOR COMMERCIAL CONSTRUCTION Roseville Electric SPECIFICATIONS FOR COMMERCIAL CONSTRUCTION REVISED 06/28/18 Commercial Construction Specifications Revision List REVISION Date Page No. Description 03/01/00 4.2-4.3 Changed leveling

More information

Approved Meter Sockets and Cabinets

Approved Meter Sockets and Cabinets Single Unit Residential Guide 1 PHASE, 120/240 VOLT SERVICES SERVICE CAPACITY OWNED METERING (Metering sockets and cabinets are supplied by Customer). Outdoor meter mounting height is 1730 mm ( 5 8 ) to

More information

Pretest Module 29 High Voltage Unit 1

Pretest Module 29 High Voltage Unit 1 Pretest Module 29 High Voltage Unit 1 1. Is a person qualified to work on high-voltage installations when this module is completed? 2. What is the code definition of high-voltage? 3. What is the IEEE definition

More information

Revised: April 2018 ¹ SERVICE TO WIRELESS DEVICE ANTENNA ATTACHMENTS ON CUSTOMER SERVICE POLES (SHEET 1) CUSTOMER: 1. An overcurrent protective device including a disconnect switch shall

More information

ELECTRIC SERVICE RULES DISTRIBUTED GENERATION Issued Jan 2016

ELECTRIC SERVICE RULES DISTRIBUTED GENERATION Issued Jan 2016 DISTRIBUTED GENERATION CHAPTER 5 500. SCOPE This chapter includes distributed or customer-owned generation connected in parallel and operating with Alliant Energy s electric distribution system. For all

More information

Item Code Description Unit Qty Total

Item Code Description Unit Qty Total UNDP ELECTRICITY SECTOR NORTHERN GOVERNORATES Phase XI Item Code Description Unit Qty Total 04-02-00001 Service Pole - 6m, 75mm dia GS Pipe 11250 04-02-00002 9m Tubular Steel Poles complete with all Accessories

More information

Approved Contractor Construction e-guide Residential Commercial

Approved Contractor Construction e-guide Residential Commercial Approved Contractor Construction e-guide Residential Commercial Clark Public Utilities PO Box 8900 Vancouver, WA 98668 (PAGE 2) TABLE OF CONTENTS PAGE Trenching 3 Wire 8 Single-Phase Transformer Set 13

More information

$ homes in a subdivision. The Fee includes an S-1 Pedestal. $ homes in a subdivision. The Fee includes an S-2 Pedestal.

$ homes in a subdivision. The Fee includes an S-1 Pedestal. $ homes in a subdivision. The Fee includes an S-2 Pedestal. ELECTRIC, GAS AND WATER Sche edulee of Charges 2017 MEMPHIS LIGHT, GAS AND WATER DIVISION MEMPHIS, TENNESSEE MEMPHIS LIGHT, GAS AND WATER DIVISION ELECTRIC SCHEDULE OF CHARGES Effective JANUARY 2017 A.

More information

Customer Requirements Downtown Secondary Network Service

Customer Requirements Downtown Secondary Network Service Application This standard describes the limitations and requirements for receiving service from the Tacoma Power secondary network system within the City of Tacoma downtown core area. In This Standard

More information

LIST OF EDD DESCRIPTION/ SPECIFICATION AS 19 TH OCTOBER 2016

LIST OF EDD DESCRIPTION/ SPECIFICATION AS 19 TH OCTOBER 2016 No Description/ Specification Amendment 1 EDD 1 :2008 11/0.415 kv Distribution Transformer, Oil Filled - 2 ED 2 :1987 The Galvanization of Iron and Steel, Articles Other Than Steel Wire - 3 ED 3 :1979

More information

Pretest Module 24 Three-phase Service Entrance

Pretest Module 24 Three-phase Service Entrance Pretest Module 24 Three-phase Service Entrance 1. What is the most widely used three-phase service entrance system? 2. What are the three most common voltage combinations for three-phase, four-wire systems?

More information

SPECIFICATIONS FOR RESIDENTIAL CONSTRUCTION

SPECIFICATIONS FOR RESIDENTIAL CONSTRUCTION Roseville Electric SPECIFICATIONS FOR RESIDENTIAL CONSTRUCTION REVISED 04/25/18 Specifications for Residential Construction Revision List REVISION Date Page No. Description 03/20/00 6.1-6.2 Added Armorcast

More information

Associated equipment As related to metering equipment: such as the current transformers, CT wiring and test switches.

Associated equipment As related to metering equipment: such as the current transformers, CT wiring and test switches. APPENDIX Glossary Approval Acceptable to the authority having jurisdiction. Assessor s Parcel Number (APN) Identifying number assigned by the county assessor s office to each taxable building lot in the

More information

Pentahead bolts See note 2. Conduit run as specified. Company facility. Refer to drawing SS8.6-2 or SS8.6-3 STANDARD SERVICE INSTALLATION

Pentahead bolts See note 2. Conduit run as specified. Company facility. Refer to drawing SS8.6-2 or SS8.6-3 STANDARD SERVICE INSTALLATION PULL BOX F SECONDARY SYSTEM Typical grade Pentahead bolts See note 2 Conduit run as specified Plastic or fiberglass for grass areas or Polymer concrete for light duty areas (see notes 2, 3, & 4) Company

More information

2. DEFINITIONS. 2.3 APPROVED Acceptable to the authority enforcing the National Electric Code

2. DEFINITIONS. 2.3 APPROVED Acceptable to the authority enforcing the National Electric Code 2. DEFINITIONS 2.1 ACCEPTABLE Acceptable to the Company. 2.2 ADVANCED METER A meter that is capable of remote reading, and is capable of storing electric consumption data at specified time intervals of

More information

COMMERCIAL QUICK REFERENCE

COMMERCIAL QUICK REFERENCE COMMERCIAL QUICK REFERENCE PROVO CITY POWER STANDARDS ELECTRICAL ENGINEERING UPDATED: 2016 SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTIFICATION. 18" MIN. OF TAIL. (NEUTRAL CONDUCTOR MUST BE WHITE OR

More information

Commercial Electric Policy

Commercial Electric Policy Commercial Electric Policy 7/19/16 1 Table of Contents General Information..3 Construction.3 Ownership.4 Multi-Unit/Multi-Service Buildings....4 Secondary Termination Enclosures.4 Meter Bases.5 Temporary

More information

Index Section 103 Joint Use. General Requirements for Installation of Attachments on Oncor Poles

Index Section 103 Joint Use. General Requirements for Installation of Attachments on Oncor Poles 103 09-17 103 Index Section 103 Joint Use Title Date Number General Requirements for Installation of Attachments on Oncor Poles... 103-100 Supply and Communication Space... 103-105 Communication Lines

More information

STOUGHTON UTILITIES ELECTRIC SERVICE RULES AND INFORMATION

STOUGHTON UTILITIES ELECTRIC SERVICE RULES AND INFORMATION CHAPTER 1 - GENERAL INFORMATION 100. Purpose 101. Codes and rules 102. Continuity of service 103. Frequency, Voltage, and Amperage Limitations 104. High voltages 105. Unusual capacity requirements 106.

More information

New Commercial Service Request-Job Process

New Commercial Service Request-Job Process New Commercial Service Request-Job Process HILCO Electric Cooperative, Inc. thanks you for the opportunity to be your electric provider. We are committed in providing you the best electric service promptly

More information

Service Requirements

Service Requirements Service Requirements General Contact Idaho Power before beginning work on any new service. All meter installations must meet current electrical code requirements and display the proper electrical permit.

More information

ELECTRIC SERVICE RULES UTILITY/CATV SERVICES Issued Jan 2016

ELECTRIC SERVICE RULES UTILITY/CATV SERVICES Issued Jan 2016 UTILITY/CATV SERVICES CHAPTER 9 900. GENERAL A. Alliant Energy receives many requests for electric service from other utilities; telephone, telecommunications companies, cable television, the Department

More information

3.1 Overview of ATCO Electric s URD System Design

3.1 Overview of ATCO Electric s URD System Design Page: 3-1 3.0 URD DESIGN GUIDELINES 3.1 Overview of ATCO Electric s URD System Design The power supply to all single lot underground residential services is through front lot service. Single phase transformers

More information

Spring Test 10 due 05/11/2013

Spring Test 10 due 05/11/2013 Spring Test 10 due 05/11/2013 Multiple Choice Identify the letter of the choice that best completes the statement or answers the question. 1. When installed in an agricultural building that houses livestock

More information

CONDUCTOR CONDUCTOR. Overhead Electric Distribution Standards INTRODUCTION

CONDUCTOR CONDUCTOR. Overhead Electric Distribution Standards INTRODUCTION INTRODUCTION 1. In order to ensure safety, certain minimum clearances shall be maintained between various circuits of an overhead distribution system. Proper clearances from joint-use utilities, railroads,

More information

Electric Service Rules

Electric Service Rules 2017 Electric Service Rules GENERAL INFORMATION TEMPORARY SERVICES OVERHEAD SERVICES UNDERGROUND SERVICES DISTRIBUTED GENERATION METERING HUD MANUFACTURED HOMES FARM SERVICES UTILITY/CATV SERVICES PRIMARY

More information

201 S. Anaheim Blvd. Page No Anaheim, CA RULE NO. 2 DESCRIPTION OF SERVICE

201 S. Anaheim Blvd. Page No Anaheim, CA RULE NO. 2 DESCRIPTION OF SERVICE 201 S. Anaheim Blvd. Page No. 3.2.1 A. GENERAL 1. The character of electric service available at any particular location should be ascertained by inquiry at the City's Electrical Engineering Division office.

More information

7. Residential Single-Family and Duplex Buildings (Dwellings)

7. Residential Single-Family and Duplex Buildings (Dwellings) Sin g le -F a mily a n d Du p le x Bu ild in g s 2016 Electric Service Requirements, 2 nd Edition Section 7 Section 7 Residential Single-Family and Duplex Buildings (Dwellings) Directory Page 7.1 General

More information

SINGLE PHASE WIRING SPECIFICATIONS

SINGLE PHASE WIRING SPECIFICATIONS SINGLE PHASE WIRING SPECIFICATIONS 1-866-MEC-ELEC (1-866-632-3532) Office Locations: Hondo Office 237 Hwy 173 N Hondo, TX 78661-0370 Fax 830.426.3335 Dilley Office 1718 W. FM 117 Dilley, TX 78017 Fax 830.965.1425

More information

See NT POWERCOS , Classification Based On Service Size.

See NT POWERCOS , Classification Based On Service Size. Newmarket-Tay Power Distribution Ltd. Conditions of Service Number: NT POWER COS 310 01 Issue Date: July, 2007 Next Review Date: February, 2020 Residential 1. Preamble This section covers all items that

More information

RATE APPLICATION MANUAL. Kansas City Board of Public Utilities

RATE APPLICATION MANUAL. Kansas City Board of Public Utilities RATE APPLICATION MANUAL Kansas City Board of Public Utilities APPROVED BY THE BPU BOARD February 1, 2017 RATES EFFECTIVE January 1, 2018 RATE APPLICATION MANUAL BOARD OF PUBLIC UTILITIES PAGE TABLE OF

More information

THREE PHASE WIRING SPECIFICATIONS

THREE PHASE WIRING SPECIFICATIONS THREE PHASE WIRING SPECIFICATIONS 1-866-MEC-ELEC (1-866-632-3532) Office Locations: Hondo Office 237 Hwy 173 N Hondo, TX 78661-0370 Fax 830.426.3335 Dilley Office 1718 W. FM 117 Dilley, TX 78017 Fax 830.965.1425

More information

Table of Contents. Electrical Service Requirements. 1. General Requirements

Table of Contents. Electrical Service Requirements. 1. General Requirements Table of Contents 1. General Requirements 1.1 General Definition.................................................... 1 1 1.2 Booklet Purpose and Organization....................................... 1-1

More information

DYNAMIC LOAD FLOW STUDIES OF DISTRIBUTION FEEDS IN THE SAN JOAQUIN VALLEY REGION

DYNAMIC LOAD FLOW STUDIES OF DISTRIBUTION FEEDS IN THE SAN JOAQUIN VALLEY REGION DYNAMIC LOAD FLOW STUDIES OF DISTRIBUTION FEEDS IN THE SAN JOAQUIN VALLEY REGION INTERIM REPORT AS OF JULY 21, 2016 PRESENTED JULY 21, 2016 1 TABLE OF CONTENTS Section Introduction Advanced Inverter Approach

More information

DS-1 (Residential) Customer Charge Per electric service account $ 8.23 $ 8.23 $ 8.23 Meter Charge Per electric service account $ 6.06 $ 6.06 $ 6.

DS-1 (Residential) Customer Charge Per electric service account $ 8.23 $ 8.23 $ 8.23 Meter Charge Per electric service account $ 6.06 $ 6.06 $ 6. Page 1 of 6 DS-1 (Residential) Customer Charge Per electric service account $ 8.23 $ 8.23 $ 8.23 Meter Charge Per electric service account $ 6.06 $ 6.06 $ 6.06 Distribution Delivery Charge (per kwh) Summer

More information

SPECIFICATIONS FOR RESIDENTIAL CONSTRUCTION

SPECIFICATIONS FOR RESIDENTIAL CONSTRUCTION Roseville Electric SPECIFICATIONS FOR RESIDENTIAL CONSTRUCTION REVISED 10/03/17 Specifications for Residential Construction Revision List REVISION Date Page No. Description 8/18/09 T.O.C., 8.1-8.1.5 &

More information

SECTION 27 - PAD-MOUNTED TRANSFORMERS TABLE OF CONTENTS

SECTION 27 - PAD-MOUNTED TRANSFORMERS TABLE OF CONTENTS CABLE AND CONDUIT ENTRANCE SINGLE-PHASE PAD-MOUNTED TRANSFORMER INSTALLATION 100 KVA AND LARGER (CONCRETE PADS ONLY) 27.05-01 CABLE AND CONDUIT ENTRANCE SINGLE-PHASE PAD-MOUNTED TRANSFORMER INSTALLATION

More information

Underground Distribution Construction Manual

Underground Distribution Construction Manual Underground Distribution Construction Manual Section E7 Earthing Approved by: A Smith de Perez Energex Limited 2014 ABN 40 078 849 055 MANUAL 00305 1. INSTALLATION Detailed earthing information may be

More information

UGI UTILITIES, INC. ELECTRIC DIVISION

UGI UTILITIES, INC. ELECTRIC DIVISION BOOK IX UGI UTILITIES, INC. ELECTRIC DIVISION BEFORE THE PENNSYLVANIA PUBLIC UTILITY COMMISSION Information Submitted Pursuant to Section 53.51 et seq of the Commission s Regulations UGI ELECTRIC EXHIBIT

More information

320A Single Phase URD Meter Loop Installations

320A Single Phase URD Meter Loop Installations 320A Single Phase URD Meter Loop Installations Location: The meter loop shall be mounted on the side of the pedestal facing the consumer's lot. (The side being one of the four flat surfaces of the pedestal

More information

Engineering Service Specifications. Commercial Single-Phase Current Transformer Metering Schemes

Engineering Service Specifications. Commercial Single-Phase Current Transformer Metering Schemes Engineering Service Specifications Commercial Single-Phase Current Transformer Metering Schemes Specifications for Commercial Underground Current Transformer Metering Requirements for a Single-Phase Customer

More information

Meter Installation. -and- Padmount Transformer Guide

Meter Installation. -and- Padmount Transformer Guide Meter Installation -and- Padmount Transformer Guide Feb. 2016 METERING REQUIREMENTS The following information shall be used as a guide for installing metering equipment. A self-contained meter has all

More information

WIRING DESIGN & PROTECTION REQUIREMENTS CHECKLIST

WIRING DESIGN & PROTECTION REQUIREMENTS CHECKLIST WIRING DESIGN & PROTECTION REQUIREMENTS CHECKLIST Use & Identification of Grounded and Grounding Conductors YES NO N/A Grounded conductors are identifiable and distinguishable from all other conductors.

More information

Volume 2 Charts, Formulas, and Other Useful Information

Volume 2 Charts, Formulas, and Other Useful Information Volume 2 Charts, Formulas, and Other Useful Information Aluminum Conductor Conductor Terminations 61 Compact Aluminum (Conduit Fill Tables) 68-79 Ampacity Dwelling Services 48 1-phase Loads on a 3-phase

More information

Niagara Mohawk Power Corporation d/b/a National Grid

Niagara Mohawk Power Corporation d/b/a National Grid Niagara Mohawk Power Corporation d/b/a National Grid PROCEEDING ON MOTION OF THE COMMISSION AS TO THE RATES, CHARGES, RULES AND REGULATIONS OF NIAGARA MOHAWK POWER CORPORATION FOR ELECTRIC AND GAS SERVICE

More information

ENTRANCE EQUIPMENT ER D PAGE 1 OF 5

ENTRANCE EQUIPMENT ER D PAGE 1 OF 5 PAGE 1 OF 5 USE: Requirements for entrance equipment. PREVIOUS REVISION 07-01-98 ORIGINATED 03-94 PREVIOUS NUMBER ER 100 (12-01-81) LATEST REVISION: Updated meter socket labeling specification and instrument

More information

PWC SCHEDULE OF DEPOSITS, FEES AND CHARGES. Table of Contents

PWC SCHEDULE OF DEPOSITS, FEES AND CHARGES. Table of Contents PWC SCHEDULE OF DEPOSITS, FEES AND CHARGES Table of Contents I. DEFINITIONS... 2 II. DEPOSITS... 3 A. Establishment of Credit... 3 B. Deposit Refunds... 4 III. CUSTOMER SERVICE FEES AND CHARGES... 4 A.

More information

SECTION 500 METERING AND ASSOCIATED EQUIPMENT

SECTION 500 METERING AND ASSOCIATED EQUIPMENT SECTION 500 METERING AND ASSOCIATED EQUIPMENT 500.0 General Meter sockets shall be provided, installed and maintained by Customer. When the ratings of meter sockets are exceeded, transockets shall be used.

More information

Installing or Rebuilding Your Electric Service

Installing or Rebuilding Your Electric Service Installing or Rebuilding Your Electric Service 2 3 Contents Policies for New and Rebuilt Electric Service 2-4 Paperwork and fees...2 Five-year policy...3 Proposed route location and conditions...3 Construction

More information

Scale of Inspection Fees of Electrical Inspectorate Schedule. I. Fees for Initial Inspections:

Scale of Inspection Fees of Electrical Inspectorate Schedule. I. Fees for Initial Inspections: PART 7 Scale of Inspection Fees of Electrical Inspectorate Schedule I. Fees for Initial Inspections: SCALE A For an inspection or test of any generating station, receiving station or other places in which

More information

Wheeler Ridge Junction Substation Project Description and Functional Specifications for Competitive Solicitation

Wheeler Ridge Junction Substation Project Description and Functional Specifications for Competitive Solicitation Wheeler Ridge Junction Substation Project Description and Functional Specifications for Competitive Solicitation 1. Description In the 2013-2014 Transmission Planning Cycle, the ISO approved the construction

More information

PWC SCHEDULE OF DEPOSITS, FEES AND CHARGES. Table of Contents

PWC SCHEDULE OF DEPOSITS, FEES AND CHARGES. Table of Contents PWC SCHEDULE OF DEPOSITS, FEES AND CHARGES Table of Contents I. DEFINITIONS... 2 II. DEPOSITS... 3 A. Establishment of Credit... 3 B. Deposit Refunds... 4 III. CUSTOMER SERVICE FEES AND CHARGES... 4 A.

More information

TEMPORARY ELECTRIC WIRING FOR CARNIVALS, CONVENTIONS, EXHIBITIONS, FAIRS AND SIMILAR USES

TEMPORARY ELECTRIC WIRING FOR CARNIVALS, CONVENTIONS, EXHIBITIONS, FAIRS AND SIMILAR USES INFORMATION BULLETIN / PUBLIC - ELECTRICAL CODE REFERENCE NO.: LAMC 93.0230 Effective: 3-24-69 DOCUMENT NO. P/EC 2002-006 Revised: 11-17-00 Previously Issued As: RGA #7-69 TEMPORARY ELECTRIC WIRING FOR

More information

PUBLIC UTILITY DISTRICT NO. 1 OF LEWIS COUNTY METERING SPECIFICATIONS

PUBLIC UTILITY DISTRICT NO. 1 OF LEWIS COUNTY METERING SPECIFICATIONS PUBLIC UTILITY DISTRICT NO. 1 OF LEWIS COUNTY METERING SPECIFICATIONS 1. General Metering Requirements a. Interpretation The District s metering requirements shall not be interpreted to conflict with the

More information

SERVICE ATTACHMENT ON A BUILDING WITH BUS DUCT SERVICE ENTRANCE AND INDOOR METERING

SERVICE ATTACHMENT ON A BUILDING WITH BUS DUCT SERVICE ENTRANCE AND INDOOR METERING SERVICE ATTACHMENT ON A BUILDING WITH BUS DUCT SERVICE ENTRANCE AND INDOOR METERING Obtain acceptance and specific details from the local Company office. 1. Service entrance duct (see Note 1). Company

More information

Clark Public Utilities Commercial Electric Service Handbook. This page left blank intentionally.

Clark Public Utilities Commercial Electric Service Handbook. This page left blank intentionally. This page left blank intentionally. 38 Chapter 4: Commercial Metering / January 2011 APPENDIX Glossary Approval Acceptable to the authority having jurisdiction. Associated equipment As related to metering

More information

7 Single Family Service

7 Single Family Service 7 Single Family Service 7. General The location of the service entrance on the Customer s premises is an important consideration. For clearance and location information see section 5 (Clearances). Consult

More information

PUBLIC UTILITY DISTRICT NO. 1 OF CHELAN COUNTY

PUBLIC UTILITY DISTRICT NO. 1 OF CHELAN COUNTY Fees and Charges PUBLIC UTILITY DISTRICT NO. 1 OF CHELAN COUNTY 1 SECTION TABLE OF CONTENTS Fees and Charges PAGE TABLE OF CONTENTS... 2 DELEGATED AUTHORITY... 3 ELECTRICAL FEES AND CHARGES... 4 SERVICE

More information

JACKSON ELECTRIC COOP METER LOOP CONSTRUCTION SPECIFICATIONS JUNE 2018

JACKSON ELECTRIC COOP METER LOOP CONSTRUCTION SPECIFICATIONS JUNE 2018 JACKSON ELECTRIC COOP METER LOOP CONSTRUCTION SPECIFICATIONS JUNE 2018 GANADO OFFICE PHYSICAL ADDRESS: 8925 State Highway 111 E Ganado, TX 77962 Phone: (361)771-4400 BAY CITY OFFICE PHYSICAL ADDRESS: 100

More information

Demand Charges to Deal With Net Energy Metering: Key Considerations

Demand Charges to Deal With Net Energy Metering: Key Considerations Demand Charges to Deal With Net Energy Metering: Key Considerations Amparo Nieto Vice President Presented at EUCI Residential Demand Charges Symposium Calgary, Canada December 1, 2015 Key Rate Design Principles

More information

SERVICE REQUIREMENTS COMMERCIAL & INDUSTRIAL CUSTOMERS

SERVICE REQUIREMENTS COMMERCIAL & INDUSTRIAL CUSTOMERS ENERGY SERVICES ENGINEERING 840 Northgate Drive Telephone (509) 942-7403 Fax (509) 942-7405 P.O. Box 190 Richland, WA 99352 www.ci.richland.wa.us SERVICE REQUIREMENTS COMMERCIAL & INDUSTRIAL CUSTOMERS

More information

CHAPTER V RESIDENTIAL WIRING

CHAPTER V RESIDENTIAL WIRING CHAPTER V RESIDENTIAL WIRING 5.1. THE SERVICE ENTRANCE Buildings and other structures receive the electrical energy through the service entrance. In residential wiring, the electric company supply this

More information

Service Requirements

Service Requirements Service Requirements General Contact Idaho Power before beginning work on any new service. All meter installations must meet current electrical code requirements and display the proper electrical permit.

More information

New Service. From... BARRON. Spooner Office: P.O. Box 261 Spooner, WI Barron Office: P.O. Box 40 Barron, WI

New Service. From... BARRON. Spooner Office: P.O. Box 261 Spooner, WI Barron Office: P.O. Box 40 Barron, WI New Service Guidelines and Diagrams From... BARRON www.barronelectric.com email: janderson@barronelectric.com Barron Office: P.O. Box 40 Barron, WI 54812-0040 Spooner Office: P.O. Box 261 Spooner, WI 54801-0261

More information

RESIDENTIAL SUBDIVISION SERVICE REQUIREMENTS SECTION VI RESIDENTIAL SUBDIVISION SERVICE REQUIREMENTS

RESIDENTIAL SUBDIVISION SERVICE REQUIREMENTS SECTION VI RESIDENTIAL SUBDIVISION SERVICE REQUIREMENTS SECTION VI SERVICE REQUIREMENTS This section discusses the requirements for establishing electric service to new residential subdivisions in Palo Alto. Subdivisions are normally constructed on dedicated

More information

For Conduit Inspections

For Conduit Inspections Underground Conduit Standards - Table of Content 5/8/2017 Section S22 Underground Conduit Standard Index: Description: 00 Table of Content 01 General Notes 02 Definition of Terms 03 Primary Riser Conduit

More information

SOUTHWEST LOUISIANA ELECTRIC MEMBERSHIP COORPORATION COMMERCIAL SERVICE REQUIREMENTS

SOUTHWEST LOUISIANA ELECTRIC MEMBERSHIP COORPORATION COMMERCIAL SERVICE REQUIREMENTS SOUTHWEST LOUISIANA ELECTRIC MEMBERSHIP COORPORATION COMMERCIAL SERVICE REQUIREMENTS November 17, 2016 Engineering Service Specifications Table of Contents Commercial Service Requirements SLEMCO Commercial

More information

TELL CITY ELECTRIC DEPARTMENT RATES AND CHARGES

TELL CITY ELECTRIC DEPARTMENT RATES AND CHARGES TELL CITY ELECTRIC DEPARTMENT RATES AND CHARGES As per Ordinances of the Common Council of the City of Tell City, Indiana 04/07/2008 Ordinance 993 05/05/2008 Ordinance 995 07/07/2008 Ordinance 1000 08/03/2009

More information

PJM SRTEP Meeting Questions Pertaining to Proposed Projects & Scopes AEP: Ambler Ridge:

PJM SRTEP Meeting Questions Pertaining to Proposed Projects & Scopes AEP: Ambler Ridge: PJM SRTEP Meeting 2-13-2018 Questions Pertaining to Proposed Projects & Scopes AEP: Ambler Ridge: The problem statement states two 138kV CB s will be installed at Ambler Ridge, however the potential solution

More information

Corrections most seen on plan review October 18, 2017 David Rankin Seattle Department of Construction and Inspections

Corrections most seen on plan review October 18, 2017 David Rankin Seattle Department of Construction and Inspections Corrections most seen on plan review October 18, 2017 David Rankin Seattle Department of Construction and Inspections One-Line / Riser Diagrams Drawings are not reviewed prior to submission. Because of

More information

CIS-IEEE 2017 Conference Renewable Energy Session Renewable Energy s Impact of Power Systems

CIS-IEEE 2017 Conference Renewable Energy Session Renewable Energy s Impact of Power Systems CIS-IEEE 2017 Conference Renewable Energy Session Renewable Energy s Impact of Power Systems Ben Huckaba, P.E. President & Principal Engineer 317-273-9841 benh@alphaeng.us Indiana University Bloomington,

More information

Customer Substation Manual

Customer Substation Manual Customer Substation Manual Table of Contents Section Page 2 of 81 Description 0 Preface 010.00 General 010.10 Information Required for the Review of New Customer Substations 010.20 New Customer Substation

More information

Parkland Light & Water Co. ELECTRIC SERVICE REQUEST AND METER STANDARDS

Parkland Light & Water Co. ELECTRIC SERVICE REQUEST AND METER STANDARDS Parkland Light & Water Co. ELECTRIC SERVICE REQUEST AND METER STANDARDS Revised: January, 2017 Contents SERVICE REQUEST FORMS RECEIPT OF ELECTRIC SERVICE REQUEST AND METER STANDARDS ELECTRIC SERVICE REQUEST

More information

TADP 548 Transmission Line Design- Electrical Aspects

TADP 548 Transmission Line Design- Electrical Aspects TADP 548 Transmission Line Design- Electrical Aspects Presentation 3.3 Electrical Design Clearances Part 6 Transmission & Distribution Program Parvez Rashid & Dr. Prasad Yenumula Electrical Design Clearances

More information

CHAPTER 3. Basic Considerations and Distribution System Layout

CHAPTER 3. Basic Considerations and Distribution System Layout CHAPTER 3 Basic Considerations and Distribution System Layout Utility Load Classifications The electrical power distribution system is that portion of the electrical system that connects the individual

More information

Transformer Protection

Transformer Protection Transformer Protection Course No: E01-006 Credit: 1 PDH Andre LeBleu, P.E. Continuing Education and Development, Inc. 9 Greyridge Farm Court Stony Point, NY 10980 P: (877) 322-5800 F: (877) 322-4774 info@cedengineering.com

More information

Generator Interconnection Facilities Study For SCE&G Two Combustion Turbine Generators at Hagood

Generator Interconnection Facilities Study For SCE&G Two Combustion Turbine Generators at Hagood Generator Interconnection Facilities Study For SCE&G Two Combustion Turbine Generators at Hagood Prepared for: SCE&G Fossil/Hydro June 30, 2008 Prepared by: SCE&G Transmission Planning Table of Contents

More information

ACTEWAGL DISTRIBUTION SCHEDULE OF ELECTRICITY NETWORK CHARGES

ACTEWAGL DISTRIBUTION SCHEDULE OF ELECTRICITY NETWORK CHARGES ACTEWAGL DISTRIBUTION SCHEDULE OF ELECTRICITY NETWORK CHARGES. The following charges will apply from 1 July 2016. Accounts issued on or after this date will be charged on a pro-rata basis. The charges

More information

TEMPORARY ELECTRICAL SERVICE

TEMPORARY ELECTRICAL SERVICE ENERGY SERVICES ENGINEERING 840 Northgate Drive Telephone (509) 942-7403 Fax (509) 942-7405 P.O. Box 190 Richland, WA 99352 www.ci.richland.wa.us/energyservices TEMPORARY ELECTRICAL SERVICE A. INTRODUCTION

More information