1 Fan coil units Model DEO - heating - cooling - ventilation

2 Fan coil units omfortable indoor climate In buildings, pleasant working and living conditions are to a large degree determined by the indoor climate. comfortable climate in a room will not go by unnoticed by staff and visitors and will give them a pleasant feeling. dded to that, a comfortable working climate will reduce the absenteeism rate among your employees and increase both their productivity and your ultimate return on investment. The iddle fan coil unit, model DEO, gives you optimum control of the indoor climate by heating, cooling and/or ventilating the room to your own liking. The DEO can be applied in refurbishment or new build projects, in offices, public buildings and similar. High quality climate The Sint-Janslyceum school in s Hertogenbosch uses free-hanging Stylish models. iddle fan coil units come as standard with components of very high quality, which help create an optimum indoor climate in each individual room. The DEO proves that a comfortable living climate and a low noise level can go very well together. The unit is positioned in the room in such a way that the discharged air stream is distributed evenly across the room without causing a nuisance to the people in it. Individual control enefits model DEO High quality climate Low sound level Individual control Various controls Wide scope of application Directional heating and cooling Many models and colours Easy installation and maintenance 5-years warranty People like to control the climate in their working environments themselves. Everyone has his or her own preference for air temperature and quality. iddle fan coil units perfectly anticipate the need to control the climate per room. Users may simply regulate the room temperature and the fresh air supply themselves. Wide scope of application The fan coil units are highly suitable for use in refurbished or newly built offices, meeting rooms, hotels, schools, care centres, hospitals, server rooms and retail outlets. The DEO model is available in a very large number of types and designs, so it can be applied in many, many situations. The free-standing usiness model fits in very well with the interior of msterdambased NS onsultants. 2

3 Optional accessories: various controls The unit can incorporate an airside controller or a combined air- and waterside controller, either option having the corresponding easy-to-use control panel. The controller provides for efficient heating and cooling at the lowest possible noise level. The controller comes standard with a weekly timer and a room thermostat and can also be combined with, for instance, a O 2 sensor, (see page 7). With a O 2 sensor the volume of fresh air can be tailored to the use of the room. omfort where you need it djustable outlet grille The air is discharged directionally, max.: 20 sideward, 10 backward and 30 forward. The iddle fan coil unit features an innovative adjustable discharge grille (Multi Vector Technology), which is made up of a number of stacked sheets with a hole pattern. Using this discharge grille, the direction of the air can be regulated. To cool a room, the air is blown into the room differently than when heating it. The grille enables the user to direct the air to or from the place where he or she is working, thus providing comfort where you need it. References N mro allast Nedam elastingkantoor ijenkorf Gasunie Research Het rsenaal (Jan des ouvrie) ING ank Heineken KPN Ned. Forensisch Instituut Novotel Mediapark Philips Radboud Ziekenhuis Sportstad Heerenveen UM Utrecht Unilever Universiteit Utrecht Easy to install and maintain ll fan coil units that have an airside or combined controller are delivered ready to use, so they are fast and easy to install. ll models come standard with a removable G2 filter. This filter prevents dust in the inlet air from settling on the battery or fans. The filter is hidden from view using a filter frame, which is easy to remove. The filter is fast and easy to clean with a vacuum cleaner. The filter can be withdrawn from the front of the unit. 3

4 Various models People prefer climate control equipment that is unobtrusive and fits in with its surroundings. That s why iddle has devoted much attention to the outward appearance of the fan coil unit, so it will fit in with any interior. s each room asks for a solution of its own, iddle offers a wide and complete range of fan coil units (± variants). eiling model (usiness) Model with casing This model is available either as a wall model (F) or as a ceiling model () and can be freely standing or suspended. The next units are available: 1. Stylish model (S): with curved plastic side covers 2. usiness model (): with straight metal side covers Recessed model The recessed model (R) is easy to integrate into the wall (F) or ceiling void (). Standard colour combinations Recessed floor model Fan coil units with casing are available in three colour combinations. Next to the conventional white colour, the unit is available in the colour titanium and in a combination of different grey tones. Unless the customer requests a specific colour, the unit comes standard in white. Other colours or colour combinations are of course available at an extra charge. Titanium (usiness) Grey tones (Stylish) White (usiness) asing Side covers Filter frame Stylish (S) RL 9002 = greyish white RL 7032 = pebble grey RL 9007 = grey aluminium RL 9010 = white RL 9010 = white RL 9006 = white aluminium usiness () Polydrox = titanium Polydrox = titanium Polydrox = titanium RL 9010 = white RL 9010 = white RL 9006 = white aluminium 4

5 Typecode DEO 75-H13-R-FS12 Unit size 50 = m 3 /h 75 = m 3 /h 100 = m 3 /h 125 = m 3 /h 150 = m 3 /h oil type H1, H2, H4 = Water heating 2, 3, 4 = Water cooling H13 = Water heating and - cooling HE = electric heating (1,2,3,4 = number of rows) Water connections R = right L = left HE = electrical connection on the left side. Model type FS = floor model: stylish F = floor model: business S = ceiling model: stylish = ceiling model: business FR = recessed Floor model R = recessed ceiling model 2-12 = see figure 1: model types Many options asic models The fan coil unit is available in 5 unit sizes: DEO 50, DEO 75, DEO 100, DEO 125 and DEO 150. The air flow rates of these types range from m³/h. Model DEO can heat, cool or ventilate the room. The unit is available in different models (see figure 1). Figuur 1: model types Free-standing Floor model (FS or F) Free-hanging eiling model (S or ) Recessed Floor model (FR) Recessed eiling model (R) FS2 F2 S2 2 Recirculation Ventilation Recirculation/Ventilation F4 S6 6 S 8 8 S10 10 S12 12 R2 R4 R6 R8 R10 R12 * ll models are available as top discharge types. Only the recessed model has the possibility of a discharge plenum for front discharge. FS6 F6 FS8 F8 FS10 F10 FS12 F12 FR2 FR4 FR6 FR8 FR10 FR12 = inspection side = air direction Floor model (Stylish) 5

6 Standard delivery Units with casing come with: adjustable discharge grille removable air filter integrated condensate draining pump (only in ceiling model with cooling mode) integrated frost-protection device and damper control (only in ventilation model) condensate tray (only in models with cooling mode) Recessed units come with: removable air filter frost-protection device (only in ventilation model) condensate tray (only in models with cooling mode) djustable discharge grille ccessories The following control accessories are available (see page 7): air side controller air- and waterside controller control panel O 2 sensor low-voltage cables (different lengths) ventilation module for coupling to an exhaust fan O 2 sensor Wall grille lso the following accessories are available. (see page 23-27): sound - damping air inlet section wall sleeve wall grate roof cap discharge plenum for recessed models flexible connection sleeves with or without duct connecting flange adjustable discharge grille wall and ceiling grilles condensate draining pump (standard in encased ceiling model with cooling mode, optional in floor model) iddle and customer may agree on custom alterations or modifications to the unit. Weights of various models The weights of the various fan coil models are represented below (in kg). Model Type DEO 50 DEO 75 DEO 100 DEO 125 DEO 150 With casing recirculation stylish ventilation (type FS and S) recirculation/ventilation With casing recirculation business ventilation (type F and ) recirculation/ventilation Recessed recirculation (type FR and R) ventilation recirculation/ventilation

7 ontrol options Model DEO is available with two types of control: an airside control and a combined air- and waterside control. The control panel allows the user to easily set the indoor climate to a comfortable level. 1. irside control This controller regulates the fan speed (3 speeds) to achieve the desired room temperature. 2. ombined air- and waterside controller This controller regulates both the fan speed and the discharge air temperature to achieve the desired room temperature. The ventilation unit is delivered with the combined controller. ontroller with LD display Waterside connection (H13) The control panel has various soft-touch keys and a clear LD display. The desired room temperature can be set using the control panel, after which you can choose to have the controller regulate the climate either automatically or using one of the three fan speeds. Next to this functionality, the control panel features an integrated weekly timer, which can be used to switch the unit automatically on and off each day of the week. The keys of the control panel can be blocked using a key lock to prevent unwanted use. One single control panel allows the user to interconnect and operate a maximum of ten units. The maximum length of the control cables within a control system is 100 metres. The control panel offers menus for different purposes, including operation, installation and service menus as well as a menu for setting the weekly timer. utomatic or manual operation The control panel allows the user to select either automatic or manual operation of the DEO. Weekly timer The DEO comes standard with a weekly timer, which allows the user to automatically switch the unit on and off per day of the week. The control panel is inclusive room thermostat. O 2 sensor The ventilation units can be equipped with a sensor to read the O 2 level in the room. The sensor ensures that the O 2 value preset in the control panel is maintained by automatically increasing or reducing the supply of fresh air. Integrated frost protection and air valve control The ventilation units have a controller-integrated frost protection thermostat and air valve control. The frost protection reduces the risk of the battery freezing (preset at 5 ). In the event of a power interruption or failure, the air valve automatically switches to the recirculation mode. Ready to use Units with an airside or combined controller are delivered ready to use. The power cable, which has a moulded-on, earthed plug, is connected to the terminal box in the side of the unit. Via the connector plate and the interfaces in the box, components such as slave units, control panel and in- and outputs can be connected to the P. Plug & play 7

8 Technical data DEO 50 Installation data electric supply V ; ph ; Hz 230 ; 1 ; 50 max. running current 0.35 max. consumed power W 90 General selection data speed tapping voltage V power consumption, fans input power, fans W air discplacement m³/h sound level d() Heating H1 LPHW 80/60 H2 LPHW 80/60 H4 LPHW 50/30 speed air displacement m³/h air inlet temperature º heating capacity kw air outlet temperature º water flow rate l/h water pressure loss kpa air inlet temperature º heating capacity kw air outlet temperature º water flow rate l/h water pressure loss kpa air inlet temperature º heating capacity kw air outlet temperature º water flow rate l/h water pressure loss kpa air inlet temperature º heating capacity kw air outlet temperature º water flow rate l/h water pressure loss kpa ooling 2 LPW 6/12º 3 LPW 6/12º 4 LPW 6/12º speed air displacement m³/h air inlet temperature º relative humidity % cooling capacity total kw cooling capacity sensible kw air outlet temperature º water flow rate l/h water pressure loss kpa * The control system limits the air discharge temperature to 50. This limitation is not included in the selection data. ** Water pressure loss, exclusive three- or two- way valve. For sft-values of three- or two-way valve, see page 22.

9 Technical data DEO 75 Installation data electrical supply V ; ph ; Hz 230 ; 1 ; 50 max. running current 0.82 max. consumed power W 180 General selection data speed tapping voltage V power consumption, fans input power, fans W air discplacement m³/h sound level d() Heating H1 LPHW 80/60 H2 LPHW 80/60 H4 LPHW 50/30 speed air displacement m³/h air inlet temperature º heating capacity kw air outlet temperature º water flow rate l/h water pressure loss kpa air inlet temperature º heating capacity kw air outlet temperature º water flow rate l/h water pressure loss kpa air inlet temperature º heating capacity kw air outlet temperature º water flow rate l/h water pressure loss kpa air inlet temperature º heating capacity kw air outlet temperature º water flow rate l/h water pressure loss kpa ooling 2 LPW 6/12º 3 LPW 6/12º 4 LPW 6/12º speed air displacement m³/h air inlet temperature º relative humidity % cooling capacity total kw cooling capacity sensible kw air outlet temperature º water flow rate l/h water pressure loss kpa * The control system limits the air discharge temperature to 50. This limitation is not included in the selection data. ** Water pressure loss, exclusive three- or two- way valve. For sft-values of three- or two-way valve, see page 22. 9

10 Technical data DEO 100 Installation data electrical supply V ; ph ; Hz 230 ; 1 ; 50 max. running current 0.82 max. consumed power W 180 General selection data speed tapping voltage V power consumption, fans input power, fans W air discplacement m³/h sound level d() Heating H1 LPHW 80/60 H2 LPHW 80/60 H4 LPHW 50/30 speed air displacement m³/h air inlet temperature º heating capacity kw air outlet temperature º water flow rate l/h water pressure loss kpa air inlet temperature º heating capacity kw air outlet temperature º water flow rate l/h water pressure loss kpa air inlet temperature º heating capacity kw air outlet temperature º water flow rate l/h water pressure loss kpa air inlet temperature º heating capacity kw air outlet temperature º water flow rate l/h water pressure loss kpa ooling 2 LPW 6/12º 3 LPW 6/12º 4 LPW 6/12º speed air displacement m³/h air inlet temperature º relative humidity % cooling capacity total kw cooling capacity sensible kw air outlet temperature º water flow rate l/h waterzijdig drukverlieswater pressure loss 10 * The control system limits the air discharge temperature to 50. This limitation is not included in the selection data. ** Water pressure loss, exclusive three- or two- way valve. For sft-values of three- or two-way valve, see page 22.

11 Technical data DEO 125 Installation data electrical supply V ; ph ; Hz 230 ; 1 ; 50 max. running current 1.2 max. consumed power W 270 General selection data speed tapping voltage V power consumption, fans input power, fans W air discplacement m³/h sound level d() Heating H1 LPHW 80/60 H2 LPHW 80/60 H4 LPHW 50/30 speed air displacement m³/h air inlet temperature º heating capacity kw air outlet temperature º water flow rate l/h water pressure loss kpa air inlet temperature º heating capacity kw air outlet temperature º water flow rate l/h water pressure loss kpa air inlet temperature º heating capacity kw air outlet temperature º water flow rate l/h water pressure loss kpa air inlet temperature º heating capacity kw air outlet temperature º water flow rate l/h water pressure loss kpa ooling 2 LPW 6/12º 3 LPW 6/12º 4 LPW 6/12º speed air displacement m³/h air inlet temperature º relative humidity % cooling capacity total kw cooling capacity sensible kw air outlet temperature º water flow rate l/h water pressure loss kpa * The control system limits the air discharge temperature to 50. This limitation is not included in the selection data. ** Water pressure loss, exclusive three- or two- way valve. For sft-values of three- or two-way valve, see page

12 Technical data DEO 150 Installation data electrical supply V ; ph ; Hz 230 ; 1 ; 50 max. running current 1.2 max. consumed power W 270 General selection data speed tapping voltage V power consumption, fans input power, fans W air discplacement m³/h sound level d() Heating H1 LPHW 80/60 H2 LPHW 80/60 H4 LPHW 50/30 speed air displacement m³/h air inlet temperature º heating capacity kw air outlet temperature º water flow rate l/h water pressure loss kpa air inlet temperature º heating capacity kw air outlet temperature º water flow rate l/h water pressure loss kpa air inlet temperature º heating capacity kw air outlet temperature º water flow rate l/h water pressure loss kpa air inlet temperature º heating capacity kw air outlet temperature º water flow rate l/h water pressure loss kpa ooling 2 LPW 6/12º 3 LPW 6/12º 4 LPW 6/12º speed air displacement m³/h air inlet temperature º relative humidity % cooling capacity total kw cooling capacity sensible kw air outlet temperature º water flow rate l/h water pressure loss kpa * The control system limits the air discharge temperature to 50. This limitation is not included in the selection data. ** Water pressure loss, exclusive three- or two- way valve. For sft-values of three- or two-way valve, see page 22.

13 Technical data DEO HE Installation data DEO 50 DEO 100 DEO 150 electrical supply 400 V; 3 ph; 50 Hz 400 V; 3 ph; 50 Hz 400 V; 3 ph; 50 Hz max. running current max. consumed power kw heating* * With electric heating, the heating capacity is 5% lower than the installed power. General selection data DEO 50 DEO 100 DEO 150 speed tapping voltage V power consumption, fans input power, fans W air displacement m 3 /h sound level d() Electrical heating DEO 50 DEO 100 DEO 150 HE 400V HE 400V HE 400V speed air displacement m³/h air inlet temperature º available heating cap. 1 kw air outlet temperature º real heating capacity kw power consumption per fase air inlet temperature º available heating cap. 1 kw air outlet temperature º real heating capacity kw power consumption per fase air inlet temperature º available heating cap. 1 kw air outlet temperature º real heating capacity kw power consumption per fase air inlet temperature º available heating cap. 1 kw air outlet temperature º real heating capacity kw power consumption per fase t some fan speeds, the available heating capacity may be higher than the real heating capacity, as the control system limits the outlet air temperature tot 50. * The DEO-75 and DEO-125 are not available as electrically heated units. 13

14 Explanation The correction coefficients are for the capacities listed in the tables on page 8 to 12. They give an indication of the capacity at deviating water temperatures and air conditions. For exact data, please seek the advice of a iddle employee. orrection coefficients for heating capacities of the battery types H1 and H2. Explanation of technical data orrection coefficients- heating capacity The heating capacities for the coil types H1 and H2 listed in the tables on pages 8 to 12 are based on a water temperature range of 80/60. The heating capacities for the coil type H4 are based on a water temperature range of 50/30. If water temperatures differ, the heating capacity is to be multiplied by the coefficients from the below tables. These coefficients are applicable to the heating capacities from the tables on pages 8 to 12 at an inlet air temperature of 20. The first table lists the correction coefficients for the coil types H1 and H2. The correction coefficients for the coil type H4 are listed in the second table. H1 and H2 LPHW ir inlet temperature -10 º 0 º 10 º 20 º 90/70 º /60 º /50 º /40 º /30 º orrection coefficients for heating capacity of the battery type H4. LPHW ir inlet temperature -10 º 0 º 10 º 20 º 90/70 º /60 º /50 º /40 º /30 º H4 orrection coefficients - cooling capacity The cooling capacities for the coil types 2, 3 and 4 listed in the tables on pages 8 to 12 are based on a water temperature range of 6/12 and on an inlet air temperature of 24 at 50% R.H. If water temperatures and inlet air conditions differ, the cooling capacity is to be multiplied by coefficients from the table on page

15 orrection factors cooling capacity coil types 2, 3 and 4. Explanation of technical data 2, 3 and 4 LPW ir inlet Relative humidity temp. 40% R.V. 50% R.V. 60% R.V. Q t Q v Q t Q v Q t Q v 6/ / / Q t = total cooling capacity Q v = sensible cooling capacity Water flow rate m w = water flow rate [l/h] Q = capacity [kw] (page 14) ρ w = density of water [kg/l] pw = specific (= 4.18) [kj/kg ] T w = temperature difference water [ ] The water flow rates listed in the tables on pages 8 to 12 are based on a water temperature range of 80/60, 50/30 or 6/12. If water flow rates differ from those listed in the tables on pages 8 to 12, the water flow rate may be roughly calculated using the opposite formula. efore doing so, the heating capacity must first be recalculated (see page 14). m w = Q ρ w pw T w 3600 [ l/h] Water pressure loss p w2 = water pressure loss [kp] p w1 = water pressure loss, table values [kp] m w1 = water flow rate, table values [l/h] m w2 = water flow rate calculated using formula [l/h] Il water temperatures differ from those listed in the tables on pages 8 to 12, then the water pressure loss may be roughly calculated using the formula below. To do so, the water flow rate must first be calculated (see above). p w2 = p w1 m ( w2 ) 2 m w1 [kpa] 15

16 Explanation of Technical data Sound In the tables on pages 8 to 13, a sound level in the reverberation field is listed for all six speeds. These sound level values are based on the use of one fan coil unit in a reference room. Unit size Reference room DEO m 3 DEO m 3 DEO m 3 DEO m 3 DEO m 3 Reference room For each type of fan coil unit, a room has been taken for expressing the noise level. The reference room (Vo) is chosen dependent on the size of the unit, such that the air circulation ratio in the room is equal to 2 at fan speed 4. The reference room is stated in the opposite table. s many offices have sound-absorbing ceilings, an average reverberation time of 0.5 second has been assumed. Deviating room and multiple units Lp = sound pressure [d()] T = reverberation value in deviating room [s] T 0 = reverberation value is 0.5 s V = volume of deviating room [m 3 ] V 0 = volume reference room [m 3 ] (see table) n = number of units If a unit is used in a deviating room or if multiple units are used in a single room, the sound level must be recalculated. This can be done using the below formula, whereby the relevant table value can be retrieved from the tables on pages 8 to 13 (general selection data per speed). Lp = table value + 10 log -10 log V +10 log (n) [d()] Sample calculation T ( ( ) ) T 0 ( V 0 ) Wanted: the noise level in the reverberation field if three DEO-75 fan coil units are used at speed 3 in a room featuring a reverberation time of 0.6 second and a volume of 600 m log -10 log +10 log (n) = 34 + ( ) = 35,9 d() ( ( ) ( ) ) 16

17 Explanation of technical data Overview of sound data Unit size Sound pres- Sound power level** sure level* in d() Per octave band in the medium frequency in d (ref 1 x W) in d() Type Speed Lp 63 Hz 125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz 4000 Hz 8000 Hz Lw DEO DEO DEO DEO DEO * The noise levels are based on the reverberation field in a reference room (see page 16). ** The value <0 indicates that the relevant value is below the threshold of hearing. 17

18 Explanation of Technical data Sound-damping air inlet section To reduce the noise, a sound-damping air inlet section can be installed in units that feature outside-air inlet. The section reduces both the outside noise coming in, such as traffic noise, and the inside noise going out, such as bar noise. The inner side of the sound-damping inlet section is finished with a sound-absorbing open-cell foam coat. The sound damping values have been measured according to NEN at the laboratory of the Groningen-based firm Van Dorsser V (The Netherlands). Damping value - sound power level [d] Mode D n *, referenced to 10 m 2 per octave band in the medium frequence Total 125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz 4000 Hz LW Damper actuator in ventilation mode Damper actuator in recirculation mode * D n is damping valve Damping value, - sound level differential per octave Ventilation Recirculation 40 D n [d] Hz 250 Hz 500 Hz 1000 Hz 2000 Hz 4000 Hz The values from the table below can be used for a simplified calculation. Damping value - sound power level [d()] Mode R,netto * DEO 50 DEO 75 DEO 100 DEO 125 DEO 150 Damper actuator in ventilation mode Damper actuator in recirculation mode wall duct [m 2 ] * R,netto is the sound reduction per type of sound-damping air inlet section. 18

19 Recirculation FS2 Dimensional sketches of stylish model (S) urved plastic side covers urved plastic side covers urved plastic side covers Ventilation Recirculation/ Ventilation Floor model, Floor model, urved plastic ceiling model also available ceiling model also available side covers Floor model, ceiling model also available FS6 FS8 FS10 FS12 Floor model, ceiling model also available Depicted model DEO 50-HI3-R-FS10 djustable discharge grille djustable discharge grille djustable discharge grille djustable discharge grille S2 S6 S8 S10 See page 5, figure 1 = inspection side = air direction Filter frame S12 Filter frame Filter frame Filter frame Inlet grille Inlet grille Inlet grilleinlet grille Removable to lead lines through Removable to lead Removable lines through to lead lines through Removable to lead lines through * * 5-20* 5-20* djusting foot djusting foot 127 djusting 20 foot djusting foot Unit size DEO DEO DEO DEO DEO Notes: ll dimensions in mm. * djusting size for adjusting feet. Only the floor model comes with adjusting feet. 19

20 Recircltaion Ventilation Straight Straight metal metal side side covers covers Floor Floor model, model, ceiling ceiling model model also also available available Recirculation/ Ventilation Dimensional sketches djustable of business djustable discharge discharge grille grille model () Depicted model DEO 50-HI3-R-F10 Straight metal side covers djustable discharge grille F2 F4 F6 F8 F10 Filter Filter frame frame F12 Floor model, ceiling model also available See page 5, figure 1 = inspection side = air direction Filter frame Inlet Inlet grille grille Inlet grille Removable Removable to to lead lead lines lines through through Removable to lead lines through ** 5-20* F4 F ** 5-20* 650 F4 djusting djusting foot foot djusting foot Unit size DEO DEO DEO DEO DEO Notes: ll dimensions in mm. * djusting size for adjusting feet. Only the floor model comes with adjusting feet. ** pplies only for encased floor model for recirculation, type F4. The minimum distance between floor and unit will then be 120 mm.

21 Floor model, Floor model, ceiling model also ceiling available model also available Dimensional sketches of ondensate discharge ondensate discharge recessed model (R) Depicted model DEO 50-HI3-L-FR10 onnector plate onnector plate Recirculation Ventilation Recirculation/ Ventilation Floor model, ceiling model also available ontrol system s FR2 FR4 FR6 FR8 FR10 FR12 onnector plate ondensate discharge R2 R4 R6 R8 R10 R12 See page 5, figure 1 = inspection side = air direction Valve motor Valve motor ontrol system Valve motor Filter ** ** Filter ** Filter Filter 612 R4 FR4 Filter 612 R4 FR * * Unit size DEO Filter R4 DEO FR DEO DEO DEO Notes: ll dimensions in mm. 253 * djusting size for adjusting feet. Only the floor model comes with adjusting feet. ** pplies only for recessed models for recirculation, types FR4 and R4. The minimum distance between floor and unit will then be 120 mm *

22 Straight side covers (model usiness) Dimensional sketches urved side covers water (model Stylish) connections Depicted model DEO 50-HI3-L-FR6 Straight side covers (model usiness) Unit size DEO DEO DEO DEO DEO urved side covers (model Stylish) oil types H1, H2, H4, H Hole in bottom to lead lines through Key holes for mounting Return Hole in bottom to lead lines through Supply Heating for 4-pipes H Squeezed joints 213 ooling for 4-pipes H13 ooling or heating for 2-pipes ondensate discharge ø 15 mm 5-20** 58*** *** Unit size oil types H1 H2 H Kvs* DN Kvs* DN Kvs* DN Kvs* DN Kvs* DN Kvs* DN DEO DEO DEO / / / / DEO / / / / DEO / / / Notes: ll dimensions in mm. With sizes and, minor deviations of 5mm at the most may occur. * Kvs values for 3- and 2-way valves. Where values vary, the 3-way valve is mentioned first, followed by the 2-way valve. ** djusting size for adjusting feet. Only the floor model comes with adjusting feet. *** Size for H1-connection if H13 is used. - pipe diameter squeezed joint DN 15: 15 mm, DN 20: 22 mm. - pipe connection can be made to both the left- and the right-hand side of the unit.

23 x x Dimensional sketches of attenuated air inlet section Depicted DEO x x Unit size DEO DEO DEO DEO DEO Notes: ll dimensions in mm. vailable for ceiling and floor models The key holes for wall mounting are identical to the back of the unit (see page 22). 23

24 Removable cover Wire grid Dimensional sketches wall and roof ducts Depicted model DEO 50 Roof cap and roof duct Material: 1.5 mm aluminium sheet 530 Removable cover Wire grid 50 Threaded Threaded connection, connection, to be drilled to be drilled after removal after removal of rain cap of rain cap rchitectural roof upstand finished with roofing Threaded connection, to be drilled after removal Wall duct and wall grate of rain cap Material: zinc coated plate steel 530 Unit Size DEO DEO DEO DEO DEO ll dimensions in mm Top view rchitectural 139 roof upstand 46 finished with 200 roofing. 206 Wall grate D E Wall grate Wall duct Wall duct Wall duct Outside of Inside Unit size D E DEO DEO DEO DEO DEO ll dimensions in mm Side view

25 Dimensional sketches discharge section Depicted recessed model DEO 50 Discharge section Material: zinc coated plate steel Possibility to install flexible sleeve and/or grille Possibility to install flexible sleeve and/or grille Unit size DEO DEO DEO DEO DEO Notes: ll dimensions are in mm. The discharge section is used in recessed models to switch from top discharge to front discharge. The discharge section may be used in conjunction with a flexible connection sleeve (see page 26) or a grille (see page 27). ir discharge spigots (Ø 125, Ø 160 and Ø 180mm) are also available. These are directly mounted to the unit. 25

26 inw Dimensional sketches flexible connection sleeves Depicted for model DEO 50 Flexible connection sleeve without duct connecting inw. flange* (for air in- and outlet sides) inw Strips and screws are included separately Unit side inw. Unit size Inlet side Outlet side D D DEO DEO DEO DEO DEO ll dimensions are in mm inw. Unit size Inlet side Outlet side DEO DEO DEO DEO DEO ll dimensions are in mm. Flexible connection sleeve with duct connecting flange* (for air in- and outlet sides) Unit side D D Notes: * Material: PV-coated polyester tissue (bisonyl). vailable with or without duct connecting flange made of zinc plated sheet steel. onnection sleeves are delivered unit-mounted. 26 D

27 206.5 djustable discharge grille Material: painted zinc plated sheet steel Dimensional sketches of wall and ceiling grilles Depicted for model DEO 50 Fin grilles Material: natural-coloured, extruded, anodised aluminium, includes a fixing frame with recessed holes. vailable in three types: Double adjustable grille Unit size DEO DEO DEO DEO DEO ll dimensions are in mm. Unit size DEO DEO DEO DEO DEO ll dimensions are in mm Single adjustable grille Unit size DEO DEO DEO DEO DEO ll dimensions are in mm. 3. Fixed grille Unit size DEO DEO DEO DEO DEO ll dimensions are in mm. Notes: These grilles can be used for both in- and outlet sides. On the outlet side, 6 the grille is mounted onto the unit using a flange. 27

28 Specifications asing The casing is made up of a front plate and side covers, and is available in different colours. The front plate is made of zinc plated sheeting with a hard epoxy polyester powder coating. The round sides are made of plastic, the straight sides of zinc plated sheeting. The structural parts are made of galvanised sheeting with extra strengthening to minimise distortion and vibrations. Where necessary, the models are insulated to reduce sound and heat transmission. Fan/Motor assembly One or more (depending on type) dual-inlet, vibration-free suspended centrifugal fans, driven by a rotor motor on ball bearings. The fan casing and the impeller are made of zinc coated plate steel. The motor is manufactured according to DIN 40050, Protection lass IP44, and Insulation lass. The motors have, as a standard, thermal contacts in the windings. These thermal contacts will break the circuit when the maximum permissible motor temperature is exceeded. Heating (LPHW) / ooling (LPW) coils The high-efficiency coils are made up of 3/8" copper pipes and aluminium fins. The coils are available with 2 or 4 rows of pipes. The maximum operating pressure is 6 bar at 120. To mount the water control unit, compression fittings are used. Then, a maximum operating pressure of 10 bar at 90 applies. Electric heating battery The electric heating battery is made up of aluminium fins. The power is controlled by the electronic control unit, which is fitted with an overload protection system. When the unit is switched off, the fans will continue to rotate until the fins have cooled off sufficiently. 28 Subject to change. iddle bv P.O. ox 15 NL-9288 ZG Kootstertille The Netherlands tel fax export@biddle.nl internet DEO.EX-G pdf 1043

Individual climate control. Fan coil units Model DECO

Individual climate control. Fan coil units Model DECO Individual climate control Fan coil units Model DECO Fan coil units Comfortable indoor climate In buildings a pleasant work and living environment are, to a large degree, determined by the quality of the

More information

Modular fan coil unit model PS

Modular fan coil unit model PS Modular fan coil unit model PS Flexible air conditioning system Modular fan coil units For the perfect indoor climate A pleasant indoor environment is largely determined by the room's climate. People often

More information

Multi directional heating. Air heaters Model NOZ

Multi directional heating. Air heaters Model NOZ Multi directional heating Air heaters Model NOZ Air heaters The ideal heat source for large buildings Air heaters are used for the heating and ventilation of large industrial buildings. New industrial

More information

COMFORT AIR CURTAIN. SensAir

COMFORT AIR CURTAIN. SensAir COMFORT AIR CURTAIN SensAir SensAir comfort air curtain Revolutionary climate separation The SensAir comfort air curtain sets a new standard in the field of climate separation. The highest level of comfort

More information

COMFORT AIR CURTAIN. SensAir

COMFORT AIR CURTAIN. SensAir COMFORT AIR CURTAIN SensAir SensAir comfort air curtain A new wave in climate separation SensAir air curtains are the ideal solution for retailers and other end-users to combat the issue of climate separation

More information

COMFORT AIR CURTAIN. SensAir

COMFORT AIR CURTAIN. SensAir COMFORT AIR CURTAIN SensAir SensAir comfort air curtain A new wave in climate separation SensAir air curtains are the ideal solution for retailers and other end-users to combat the issue of climate separation

More information

Highline 260i EC Waterside Fan Coil Unit

Highline 260i EC Waterside Fan Coil Unit Features: Electronically Commutated (EC) fan motor Specific Fan Power of 0.16 to 0.34 at NR Insignificant fan heat gain Designed to operate below NR at External Static Pressures of up to 50Pa Variable

More information

KLIMA Active Chilled Beams

KLIMA Active Chilled Beams KLIMA 2 600 Active Chilled Beams 0 Index Subject Page Index 1 Introduction 2 General description 3-4 Product features 5-6 Dimensions 7 Performance data 8-11 Selection example 12 Guide specifications 13

More information

UTA STANDARD. Ductable units. Range. Air handling unit with high available static pressure. NEW Eco-Design Filter. V3000 control Fresh air management

UTA STANDARD. Ductable units. Range. Air handling unit with high available static pressure. NEW Eco-Design Filter. V3000 control Fresh air management Ductable units NEW Eco-Design Filter Air handling unit with high available static pressure V3000 control Fresh air management The range of air handling units is designed for suspended ceiling heating and

More information

MAJOR 2 NCH. Ductable units. High pressure and high capacity ductable units RANGE NCH Y NCH NCH I COADIS COMBI. Motor optional

MAJOR 2 NCH. Ductable units. High pressure and high capacity ductable units RANGE NCH Y NCH NCH I COADIS COMBI. Motor optional Y + U I COADIS COMBI High pressure and high ductable units Motor optional is a non independent air conditioning terminal unit for heating and cooling offices and hotels. With reduced dimensions and designed

More information

CMTE. Tangential Fan Coil Series with Electronic Controlled Motor

CMTE. Tangential Fan Coil Series with Electronic Controlled Motor Tangential Fan Coil Series with Electronic Controlled Motor Designed by Very Low Electric Energy Consumption High Efficiency Extremely Low Noise Level Infra Red Remote Control Step-less Fan Speed Control

More information

42AM. Air heaters. product selection. the best solution for heating large spaces. ensures buildings warm up ultra-fast

42AM. Air heaters. product selection. the best solution for heating large spaces. ensures buildings warm up ultra-fast product selection the best solution for heating large spaces ensures buildings warm up ultra-fast excellent diffusion via patented JET+ double deflection technology ir heaters 4M Translation of the original

More information

GigaBox centrifugal fans Product specific information

GigaBox centrifugal fans Product specific information GigaBox centrifugal fans Product specific information GigaBox and accessories Wall bracket GB-WK (ccessories) Outdoor cover hood GB-WSD (ccessories) Included in delivery: a) Flexible sleeve b) Outlet spigot,

More information

The World Leading Air-conditioning Company

The World Leading Air-conditioning Company The World Leading Air-conditioning Company Table of Contents DESCRIPTIONS Model Number Nomenclature Features & Benefits Physical Dimension Fan Performance Curve (4 Row) - 40LMA024 with AC Motor - 40LMA040

More information

Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Water terminals SYSCOIL. Centrifugal fan coil units

Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Water terminals SYSCOIL. Centrifugal fan coil units Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Water terminals SYSCOIL Centrifugal fan coil units SYSCOIL Fan coil units Compact, slim fan coil units. Available

More information

Features: Available in horizontal and vertical units

Features: Available in horizontal and vertical units Features: Available in horizontal and vertical units Ideal for Shopping Malls, Retail Outlets and Office Receptions Can be supplied in a large range of colours and finishes Numerous mounting bracket arrangements

More information

Centriflow Plus EC. Technical data

Centriflow Plus EC. Technical data Technical data Centriflow Plus CTLOGUE Contents General description...3 General survey chart...4 Design description Fan Impeller...5 Inlet cone and supporting frame...5 EC motor...5 ir flow sensor...6

More information

CENTRIFUGAL FAN COIL UNIT VCE

CENTRIFUGAL FAN COIL UNIT VCE CENTRIFUGAL FAN COIL UNIT VCE 0,51 kw 11,00 kw 0,85 kw 23,75 kw 129 m 3 /h 2003 m 3 /h VCE DESIGN QUALITY COMFORTRELIABILITY 3VERSION12 SIZE DESIGN VCEx0 vertical with cabinet Air intake: bottom vertical

More information

Fan coil units MAJOR 2 CV/CH

Fan coil units MAJOR 2 CV/CH CH 41 D CV 1 D MAJOR 2: Design and performance HEE impeller for increased performance Motor optional MAJOR 2 is a non-independant chilled and/or hot water supplied air conditioning Comfort unit for the

More information

Chassis Access Fans Motors Speed Control Coils The Condensate Tray Insulation Spigots Controls Enclosure Control Valves Filters Rev A

Chassis Access Fans Motors Speed Control Coils The Condensate Tray Insulation Spigots Controls Enclosure Control Valves Filters Rev A Chassis panelwork is all In House manufactured from nominally 1.2mm Galvanised steel. Where at all possible, flanges are formed inward facing to prevent exposure to bare metal edges. Sufficient forms and

More information

Modular Air Handling. Up to 3,500 Litres / sec. Low profile & Plant room application. Draft. Version. Second Edition A-. AirDesign 2015 AirDesign 2016

Modular Air Handling. Up to 3,500 Litres / sec. Low profile & Plant room application. Draft. Version. Second Edition A-. AirDesign 2015 AirDesign 2016 Modular Air Handling U n i t R a n g e Up to 3,500 Litres / sec Low profile & Plant room application AirDesign 2015 AirDesign 2016 Second Edition Draft Version A-. Air Design is a proud Australian based

More information

NEW. Wall controls. YFCN Fan Coil Units. Technical Guide - for internal distribution only

NEW. Wall controls. YFCN Fan Coil Units.     Technical Guide - for internal distribution only NEW Wall controls Fan Coil Units www.euroventcertification.com www.certiflash.com Technical Guide for internal distribution only CONTENTS Construction Page 4 s Page 5 Dimension, Weight, Water content Page

More information

Features: Concealed installation. Compact design. Available in electric, LPHW or ambient.

Features: Concealed installation. Compact design. Available in electric, LPHW or ambient. Features: Concealed installation. Compact design. Available in electric, LPHW or ambient. Grille can be supplied in a large range of colours. Energy saving controls option available. Application The Diffusion

More information

Engineering Data Manual. New : available with EC motor. High Static Pressure Ductable Fan Coil Unit. Models 07 to to 4650 m 3 /h

Engineering Data Manual. New : available with EC motor. High Static Pressure Ductable Fan Coil Unit. Models 07 to to 4650 m 3 /h Engineering Data Manual New : available with EC motor VH High Static Pressure Ductable Fan Coil Unit Models 07 to 27 800 to 4650 m 3 /h General Characteristics Presentation On model VH 07, coils have 4

More information

Fan Coil Units. Technical Data. Conceiled ceiling unit ECDEN FWB-BT

Fan Coil Units. Technical Data. Conceiled ceiling unit ECDEN FWB-BT Fan Coil Units Technical Data Conceiled ceiling unit ECDEN10-400 FWB-BT Fan Coil Units Technical Data Conceiled ceiling unit ECDEN10-400 FWB-BT TABLE OF CONTENTS FWB-BT 1 Features.............................................................

More information

AHPHX Compact. Heat Recovery Air Handling Unit. BIM & REVIT Engineering Solutions. Acoustic Testing Laboratory College of Science & Technology

AHPHX Compact. Heat Recovery Air Handling Unit. BIM & REVIT Engineering Solutions. Acoustic Testing Laboratory College of Science & Technology HANDLERS LTD AHPHX Compact Heat Recovery Air Handling Unit 1262 Acoustic Testing Laboratory College of Science & Technology BIM & REVIT Engineering Solutions The Company Air Handlers has been trading since

More information

AHTW Compact. Heat Recovery Air Handling Unit. BIM & REVIT Engineering Solutions. Acoustic Testing Laboratory College of Science & Technology

AHTW Compact. Heat Recovery Air Handling Unit. BIM & REVIT Engineering Solutions. Acoustic Testing Laboratory College of Science & Technology HANDLERS LTD AHTW Compact Heat Recovery Air Handling Unit 1262 Acoustic Testing Laboratory College of Science & Technology BIM & REVIT Engineering Solutions The Company Air Handlers has been trading since

More information

Hydropac. Waterside Control Fan Coil Units For Horizontal and Vertical Applications. June Hydropac. Features

Hydropac. Waterside Control Fan Coil Units For Horizontal and Vertical Applications. June Hydropac. Features June 2003 Hydropac Hydropac Waterside Control Fan Coil Units For Horizontal and Vertical Applications Features Flush panel extra rigid construction. Low noise levels. Eleven speed transformer. Full acoustic

More information

PVHRU Max Quiet. Engineering Solutions. Packaged Void Heat Reclaim Unit. Acoustic Testing Laboratory College of Science & Technology

PVHRU Max Quiet. Engineering Solutions. Packaged Void Heat Reclaim Unit. Acoustic Testing Laboratory College of Science & Technology AIR HANDLERS LTD PVHRU Max Quiet Packaged Void Heat Reclaim Unit 1262 Acoustic Testing Laboratory College of Science & Technology Engineering Solutions The Company Air Handlers has been trading since May

More information

Duct Fans - ESTOC EC Range. Estoc EC Features. Electrical Supply. Sizes 355, 400, 450, 500, 560 and 630. Product Code

Duct Fans - ESTOC EC Range. Estoc EC Features. Electrical Supply. Sizes 355, 400, 450, 500, 560 and 630. Product Code Tubes and ox Fans Duct Fans - ESTOC EC Range Features Sizes from 55 to 6 mm diameter ir flow 19, m /h (4. m /s) Static pressures up to 84 Pa Maximum temperature up to 6 C Controllable external rotor motors

More information

Fan coil unit NBS 100/150

Fan coil unit NBS 100/150 Fan coil unit /150 Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telephone +49 (0) 74 63-980 - 0 Fax +49 (0) 74 63-980 - 200 info@schako.de www.schako.de Contents Description...3 Advantages...3

More information

Submittal. RBHR Horizontal Low Profile Concealed with Plenum FCU-RBHR Top View (Drain Pan Omitted) Bottom View. Front View.

Submittal. RBHR Horizontal Low Profile Concealed with Plenum FCU-RBHR Top View (Drain Pan Omitted) Bottom View. Front View. Horizontal Low Profile oncealed with Plenum FU-RBHR-1.0 05-11-17 Top View (rain Pan Omitted) Left hand unit shown. ll dimensions are inches [millimeters]. [8] 26 [6] 21 [533] 27 [686] 31 [787] 41 [1041]

More information

CENTRIFLOW 3D WITH EC MOTOR >> Technical catalogue

CENTRIFLOW 3D WITH EC MOTOR >> Technical catalogue CENTRIFLOW 3D Plug Fan WITH EC MOTOR >> Technical catalogue air comfort CentriFlow 3D 2 GMEC CentriFlow 3D - Technical Catalogue Contents GENERL Description and survey chart pplication... 3 General Survey

More information

Cert. n 0545 Carisma CRC Fan Coil Unit The Ultra Quiet Fan Coil TECHNICAL GUIDE

Cert. n 0545 Carisma CRC Fan Coil Unit The Ultra Quiet Fan Coil TECHNICAL GUIDE Cert. n 0545 www.euroventcertification.com Carisma Fan Coil Unit The Ultra Quiet Fan Coil TECHNCAL GUDE Carisma CONTENTS Construction Page 4 s Page 5 Dimension, Weight, Water content Page 6 EUROENT certification

More information

Ocelot vertical fan coil unit

Ocelot vertical fan coil unit Ocelot vertical fan coil unit 250mm Deep vertical Waterside control Cased unit DUNHAM BUSH OCELOT VERTICAL CASED FAN COIL UNIT The Dunham Bush Ocelot fan coil unit is a fully cased vertical unit suitable

More information

Swegon PACIFIC. Integrated climate beam

Swegon PACIFIC. Integrated climate beam Swegon Integrated climate beam www.eurovent-certification.com www.certiflash.com climate beam The is a high performance climate beam for installation in false ceilings. With high built-in flexibility,

More information

Swimming Pool CSR2 Heat Recovery Equipment

Swimming Pool CSR2 Heat Recovery Equipment Swimming Pool CSR2 Heat Recovery Equipment LIFETIME WARRANTY OVER 90% HEAT RECOVERY LOW CARBON British manufacturing at its best EcoAir Box is a trademark of IPT +44 (01527) 492770 www.ecoairbox.co.uk

More information

Fan Coil Units. Technical Data ECDEN FWL-DT/DF

Fan Coil Units. Technical Data ECDEN FWL-DT/DF Fan Coil Units Technical Data ECDEN10-400 FWL-DT/DF Fan Coil Units Technical Data ECDEN10-400 FWL-DT/DF TABLE OF CONTENTS FWL-DT/DF 1 Features.............................................................

More information

Total comfort control

Total comfort control Total comfort control YORK ACTIVE CHILLED BEAM WITH PERFORATED RETURN DIFFUSER Table of contents Concept & Technology Air Distribution & Facade Orientation Product Features Dimensions Performance Data

More information

HIGH EFFICIENCY ROTARY WHEEL - HELPING TO SAVE ENERGY AND REDUCE CARBON EMISSIONS.

HIGH EFFICIENCY ROTARY WHEEL - HELPING TO SAVE ENERGY AND REDUCE CARBON EMISSIONS. XBOXER THERMAL WHEEL HEAT RECOVERY UNITS HIGH EFFICIENCY ROTARY WHEEL - HELPING TO SAVE ENERGY AND REDUCE CARBON EMISSIONS. 118 029 2085 8200 XBOXER THERMAL WHEEL BENEFITS HIGH EFFICIENCY Up to 85% efficient

More information

Ductable Modular Fan Coil Unit VPX. Technical Brochure TM VPX-W.2GB Date : May 2004 Supersedes : TM VPX-W.1GB/08.03

Ductable Modular Fan Coil Unit VPX. Technical Brochure TM VPX-W.2GB Date : May 2004 Supersedes : TM VPX-W.1GB/08.03 Ductable Modular Fan Coil Unit VPX Technical Brochure TM VPX-W.2GB Date : May 2004 Supersedes : TM VPX-W.1GB/08.03 Design Features Presentation The VPX fan coil unit has been specially designed to meet

More information

Chiller, Close control and Water terminals. Air Conditioning. Light Commercial, Commercial and Industrial

Chiller, Close control and Water terminals. Air Conditioning. Light Commercial, Commercial and Industrial Chiller, Close control and Water terminals Air Conditioning Light Commercial, Commercial and Industrial Water Terminals 133 Water Terminals Fan coils & Cassette Centrifugal fan-coil SYSCOIL Ductable fan-coil

More information

Systempac. Fan Coil Unit / Acoustic Flex / Diffuser System Package. Systempac. January Features and Design Guide

Systempac. Fan Coil Unit / Acoustic Flex / Diffuser System Package. Systempac. January Features and Design Guide January 2002 Systempac Features and Design Guide Specifically Designed for Design and Build Projects. Complete package including Waterside Control Fan Coil Unit / Controls / Flexible Ducting / Plenum Box

More information

ERP 2015 Regulation (EU) Compliant with. No. 327/2011. Cert. n Heating. Meltemi Door Curtains

ERP 2015 Regulation (EU) Compliant with. No. 327/2011. Cert. n Heating. Meltemi Door Curtains Compliant with ERP 015 Regulation (EU) No. 7/011 Cert. n 0545 Heating Door Curtains The range of SBIN door curtains offers imum flexibility in the protection of doors and open access compartments. By connecting

More information

Ceiling swirl diffusers

Ceiling swirl diffusers X X testregistrierung Ceiling swirl diffusers Type Horizontal swirling air discharge Vertical air discharge Protective cage For high rooms, with adjustable air control blades Square ceiling swirl diffusers,

More information

OptimAir NF. Active Chilled Beam OptimAir NF. Nov

OptimAir NF. Active Chilled Beam OptimAir NF. Nov OptimAir NF Active Chilled Beam OptimAir NF Functions The OptimAir active chilled beam is a two-way induction type air-conditioningunit that is designed for integrated installation, mounted directly in

More information

TECHNICAL DOCUMENTATION WOLF AIR HEATERS LH-EC / LH. 30m 3 /h

TECHNICAL DOCUMENTATION WOLF AIR HEATERS LH-EC / LH. 30m 3 /h TECHNICAL DOCUMENTATION WOLF AIR HEATERS LH-EC / LH 30m 3 /h THE EXTENSIVE EQUIPMENT RANGE from system supplier WOLF offers the ideal solution for commercial and industrial buildings, new build and modernisation

More information

TECHNICAL MANUAL ESTRO BLDC ESTRO BLDC FAN COILS - BRUSHLESS TECHNOLOGY. 1.5 kw kw

TECHNICAL MANUAL ESTRO BLDC ESTRO BLDC FAN COILS - BRUSHLESS TECHNOLOGY. 1.5 kw kw GB TECHNICAL MANUAL ESTRO BLDC ESTRO BLDC FAN COILS - BRUSHLESS TECHNOLOGY 1.5 kw - 9.0 kw TABLE OF CONTENTS 1 Generalities... 3 2 Models and constructive components...4-5 3 Accessories available... 6

More information

BRIZA 22 HYBRID HEATING & COOLING

BRIZA 22 HYBRID HEATING & COOLING BRIZA 22 HYBRID HEATING & COOLING Built-in Ceiling: BABC/BT BABC/FT Built-in Wall: BABW/BT BABW/BF BABW/FT BABW/FF INFO SHEET BRIZA 22 HYBRID, COMPACT FANCOIL With EC Greentech EBM-PAPST technology Europe

More information

HEAT-RECOVERY UNITS WITH ENTHALPY/ROTARY HEAT EXCHANGER TECHNICAL MANUAL

HEAT-RECOVERY UNITS WITH ENTHALPY/ROTARY HEAT EXCHANGER TECHNICAL MANUAL UT REC - R HEAT-RECOVERY UNITS WITH ENTHALPY/ROTARY HEAT EXCHANGER TECHNICAL MANUAL 1 CONTENTS GENERAL FEATURES... 3 Scope of the unit... 3 Available configurations... 3 Description of the components...

More information

fåçìëíêá~ä=~áê=åççäéêë=qvo pí~åç~êç=åççäéêë=ïáíü=ëí~áåäéëë=ëíééä=íìäáåö

fåçìëíêá~ä=~áê=åççäéêë=qvo pí~åç~êç=åççäéêë=ïáíü=ëí~áåäéëë=ëíééä=íìäáåö fåçìëíêá~ä=~áê=åççäéêë= pí~åç~êç=åççäéêë=ïáíü=ëí~áåäéëë=ëíééä=íìäáåö O `çåíéåíë= page Model indication..................................2 Eurovent.......................................2 Capacities......................................2

More information

Versatility. Features. By installing the SILENT MV, you will never experience the disturbance of noisy ventilation again. Benefits

Versatility. Features. By installing the SILENT MV, you will never experience the disturbance of noisy ventilation again. Benefits Ultra quiet and low profile helicocentrifugal in-line fans suitable for a wide range of domestic and commercial applications. Fitted with sound absorbent insulation and manufactured with an adjustable

More information

Chiller Close Control Water terminals SYSCASSETTE. Water cassette units

Chiller Close Control Water terminals SYSCASSETTE. Water cassette units Chiller Close Control Water terminals SYSCASSETTE Water cassette units SYSCASSETTE Water cassette Available accessories Available in 8 different sizes and 2 versions. Due to its square design these units

More information

DATA & FACTS Decentral Systems Comfort - Fan Coil Units Flex-Geko Comfort Edition. Flexible solution for any requirement

DATA & FACTS Decentral Systems Comfort - Fan Coil Units Flex-Geko Comfort Edition. Flexible solution for any requirement DT & FTS Decentral Systems omfort - Fan oil Units Flex-Geko omfort Edition Flexible solution for any requirement Flex-Geko omfort Edition opyright note Disclosing, copying, distributing or taking any action

More information

Carisma The Ultra Quiet Fan Coil

Carisma The Ultra Quiet Fan Coil Carisma The Ultra Quiet Fan Coil Air Conditioning Carisma / CRR Fan Coil Units Quality management systems SO 900 Cert. n 0545/4 www.euroventcertification.com www.certiflash.com CONTENTS Construction ()

More information

MegaBox Product-specific information

MegaBox Product-specific information MegaBox Product-specific information Application Noise-encapsulating centrifugal fans with retractable motor impeller unit and motor located outside the air flow Suitable for rough operating conditions

More information

Innovative, High Performance, Quiet Units.

Innovative, High Performance, Quiet Units. Fan Coil Units Innovative, High Performance, Quiet Units. Technical Brochure TM AQF-A.4GB Date : January 2006 Supersedes : TM AQF-A.3GB/04.04 Quality, efficiency and reliability, built into every unit...

More information

^áêëçåâ=ìåáí=åççäéêë=qvoj^ pí~åç~êç=åççäéêë=ïáíü=pí~áåäéëë=píééä=íìäáåö

^áêëçåâ=ìåáí=åççäéêë=qvoj^ pí~åç~êç=åççäéêë=ïáíü=pí~áåäéëë=píééä=íìäáåö ^áêëçåâ=ìåáí=åççäéêë= pí~åç~êç=åççäéêë=ïáíü=pí~áåäéëë=píééä=íìäáåö O `çåíéåíë= page Model indication................................ 2 Eurovent...................................... 2 Capacities.....................................

More information

AHN 064 to 304 EHN/CHN 064 to 304

AHN 064 to 304 EHN/CHN 064 to 304 u Horizontal Packaged and Split Air Conditioners AHN 64 to 34 EHN/CHN 64 to 34 6. to 29.2 kw 6.4 to 29.4 kw Engineering Data Manual EDM AECHN-A.1GB Date : June 28 Supersedes : None Technical Description

More information

Küba SG industrial

Küba SG industrial 66 Küba Blue Line : Specific advantages The is a master of customisation. No matter how great the demand for power, the is the answer. Its versatility allows the Küba SG industrial to master the most complex

More information

CCE - Adaptable active chilled beam for exposed installation. Halton CCE. Adaptable active chilled beam for exposed installation

CCE - Adaptable active chilled beam for exposed installation. Halton CCE. Adaptable active chilled beam for exposed installation Halton CCE Adaptable active chilled beam for exposed installation Combined cooling, heating, and supply air unit for exposed installation Ideal solution for applications where good indoor environment,

More information

technical data air conditioning systems Round Flow Cassette FXFQ-P9VEB

technical data air conditioning systems Round Flow Cassette FXFQ-P9VEB technical data Round Flow Cassette FXFQ-P9VEB air conditioning systems technical data Round Flow Cassette FXFQ-P9VEB air conditioning systems TABLE OF CONTENTS FXFQ-P9VEB 1 Specifications.......................................................

More information

Product Catalogue ARMONIA Providing indoor climate comfort

Product Catalogue ARMONIA Providing indoor climate comfort Product Catalogue ARMONIA Providing indoor climate comfort ARMONIA 1,3-11 kw Water cassette Main applications Light commercial buildings Offi ces Shops General description Why this choice? Silent operation

More information

ULTRA LOW ENERGY. VHR Void Series W/I/s TOTAL SFP Typical. Made in the UK. VHR Void Mounted Heat Recovery Units VHR PERFORMANCE OVERVIEW:

ULTRA LOW ENERGY. VHR Void Series W/I/s TOTAL SFP Typical. Made in the UK. VHR Void Mounted Heat Recovery Units VHR PERFORMANCE OVERVIEW: VHR Void Mounted Heat Recovery Units TM.72 W/I/s TOTAL SFP Typical General: Units shall be manufactured from high quality galvanized sheet steel with stainless steel drain trays, acoustic, non-hygroscopic

More information

Manual Comfort air curtain Model CITY

Manual Comfort air curtain Model CITY Manual Comfort air curtain Model CITY Version of Guide: 4.6 R a Copyright and trademarks All the information and draings in this manual are the property of Biddle and may not be used (other than for the

More information

CENTRIFLOW 3D WITH AC MOTOR >> Technical catalouge

CENTRIFLOW 3D WITH AC MOTOR >> Technical catalouge CENTRIFLOW 3D plug fan WITH AC MOTOR >> Technical catalouge air comfort Centriflow 3D 2 GMEB CentriFlow 3D - Technical Catalouge Contents GENERAL Description and survey chart Application... 3 General Survey

More information

Guide Specifications. General. Casing. Coil/Drain pan. Fan/Motor

Guide Specifications. General. Casing. Coil/Drain pan. Fan/Motor Guide Specifications General CR-A series ducted concealed chilled water fan coil units have an air flow range from 45 to 3060 cubic meters per hour with a capacity range from kw up to 9 kw. The CR-A series

More information

Silent centrifugal air heater hot water supply

Silent centrifugal air heater hot water supply Large range : 5 to 120 Flows : 900 to 14000 m 3 /h Numerous accessories Design integrating perfectly in public buildings USE Operation in zones ES and S Extra silent and silent Forced air heating for premises

More information

Warning. Document ref: A October 2015

Warning. Document ref: A October 2015 Sentry Door Curtain Installation, Operation & Maintainance Instructions Dunham-Bush Ltd, Downley Road, Havant, Hampshire, P09 2JD Tel. 023 9247 7700 Email. info@dunham-bush.co.uk Document ref: 128-000-001-A

More information

Exhaust Fans CATALOGUE 2013 / 14

Exhaust Fans CATALOGUE 2013 / 14 Exhaust Fans CTLOGUE 2013 / 14 We are proud to introduce the first models of our new series ETMSTER. Our new design has successfully exceeded the excellent efficiency of the ETLINE series and we have improved

More information

ROOF MOUNTED FANS MIXVENT-TH Series Mixed Flow Fans MIXVENT-TH. Roof mounted fans. Flame retardant terminal box. Circular spigot coupling

ROOF MOUNTED FANS MIXVENT-TH Series Mixed Flow Fans MIXVENT-TH. Roof mounted fans. Flame retardant terminal box. Circular spigot coupling MIXVENT-TH ROOF MOUNTED FNS MIXVENT-TH Series Mixed Flow Fans Range of roof mounted mixed flow fans supplied as standard for extract operation. The models 500 and 800 are manufactured from high strength

More information

SILENT MV Ultra Quiet In-line Fans

SILENT MV Ultra Quiet In-line Fans Ultra Quiet In-line Fans 5 IP44 2 YEAR GUARANTEE Ultra quiet and low profile helicocentrifugal in-line fans suitable for a wide range of domestic and commercial applications. Fitted with sound absorbent

More information

Centrifugal performance characteristics with axial flow pattern: RADAX VAR

Centrifugal performance characteristics with axial flow pattern: RADAX VAR High pressure in-line mixed-flow fans RADAX VAR Centrifugal performance characteristics with axial flow pattern: RADAX VAR COMPACT PRESSURE-RESISTANT UNIVERSAL In their compact casing, the RADAX VAR impellers

More information

Linear Slot Diffusers Model Slot 20 & Model Slot 25

Linear Slot Diffusers Model Slot 20 & Model Slot 25 Model Slot & Model Slot 25 Contents Introduction!!!!!! Page 3 Di"user Specification!!!! Page 4 Air Patterns!!!!!! Page 5 Flange Styles!!!!!! Page 6 Corner Sections!!!!! Page 7 Selection Procedure!!!! Page

More information

Total cooling capacity kw Total heating capacity kw Features

Total cooling capacity kw Total heating capacity kw Features Room Fan Coils Idrofan Quality Management Systems 42N Total cooling capacity 0.75-6.35 kw Total heating capacity 0.60-9.50 kw The new generation 42N_S product range combines aesthetic and attractive design

More information

Air Curtains for Revolving Doors

Air Curtains for Revolving Doors Air Curtains for Revolving Doors Air curtains for revolving doors ROTOWIND The design of buildings with revolving doors that integrate with the environment is a common solution when the entrance has adverse

More information

Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE C 30 C 35 C 40 C 45 C LWB C. Sens Cap KW

Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE C 30 C 35 C 40 C 45 C LWB C. Sens Cap KW R410a Refrigerant SHS1 Split Ducted Model INDOOR COIL ENTERING AIR TEMP DB WB 21 23 2 27 29 31 Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE 30 3 40 4 17 14.0 9.1 9.8 13.2 8.8 9.0 12. 8. 12.9

More information

BACKWARD CURVE CENTRIFUGAL FANS KABB / KABT Series

BACKWARD CURVE CENTRIFUGAL FANS KABB / KABT Series Cabinet fans manufactured from galvanised steel sheet with double thickness side panels lined with 17 mm thickness of fireproof fibreglass acoustic insulation (M0). Circular duct connection flange on the

More information

BRIZA EC 12 HYBRID. World s slimmest fan coil HEATING AND COOLING

BRIZA EC 12 HYBRID. World s slimmest fan coil HEATING AND COOLING World s slimmest fan coil wall and ceiling installation 2-or 4-Pipe system heating and / or cooling with or without enclosure easy installation 24VDC EC motor silent, powerful, economical, sustainable

More information

fåçìëíêá~ä=~áê=åççäéêë=qelo pí~åç~êç=åççäéêë=ïáíü=`ì=íìäáåö

fåçìëíêá~ä=~áê=åççäéêë=qelo pí~åç~êç=åççäéêë=ïáíü=`ì=íìäáåö = pí~åç~êç=åççäéêë=ïáíü=`ì=íìäáåö O `çåíéåíë= page Model indication..................................2 Eurovent.......................................2 Capacities......................................2

More information

CONFIGURABLE HIGH-EFFICIENCY HEAT RECOVERY UNITS CADB/T-HE PRO-REG Series

CONFIGURABLE HIGH-EFFICIENCY HEAT RECOVERY UNITS CADB/T-HE PRO-REG Series False-ceiling models CADB/T-HE 4 to 33 Heat Recovery Compact heat recovery unit with high-efficiency (up to 93%) counter-flow heat exchanger, EUROVENT certified. The casing is made from plasticised galvanised

More information

ROOF MOUNTED FANS TH-MIXVENT Series Mixed Flow Fans TH-MIXVENT. Roof mounted fans. Flame retardant terminal box. Circular spigot coupling

ROOF MOUNTED FANS TH-MIXVENT Series Mixed Flow Fans TH-MIXVENT. Roof mounted fans. Flame retardant terminal box. Circular spigot coupling ROOF MOUNTED FNS Series Mixed Flow Fans P P L I T I O N S Workshops ommercial premises Offices Restaurants and cafes Wine cellars asements Range of roof mounted mixed flow fans supplied as standard for

More information

MTD Silent Series MIXED FLOW IN-LINE DUCT FAN

MTD Silent Series MIXED FLOW IN-LINE DUCT FAN MT Silent Series MIX LOW IN-LIN UT N Mixed low In-Line uct an MT Silent Series MT Silent 100/2~200/2 MT Silent 250~315 Low profile Mixed-flow fans with sound- absorbent insulation. xtreme ly quiet. General

More information

TECHNICAL GUIDE R410a SPLIT SYSTEM 1.5 to 5.0 NOMINAL TONS

TECHNICAL GUIDE R410a SPLIT SYSTEM 1.5 to 5.0 NOMINAL TONS Version.MDT-2016.T3.103 TECHNICAL GUIDE R410a SPLIT SYSTEM 1.5 to 5.0 NOMINAL TONS FEATURES AND BENEFITS COMPRESSOR: Compressors are protected with internal temperature and current overloads. An internal

More information

OTHER PRODUCTS FROM THE TURNBULL & SCOTT RANGE

OTHER PRODUCTS FROM THE TURNBULL & SCOTT RANGE OTHER PRODUCTS FROM THE TURNBULL & SCOTT RANGE THERMOLIER UNIT HEATERS TRENCH HEATING DADO HEATING RAIL HEAT EXCHANGERS GILLED TUBING RADIANT STRIP BLAST COOLERS RADIANT PANELS SKIRTING HEATING BOILER

More information

BRIZA Super slim and powerful heating, cooling

BRIZA Super slim and powerful heating, cooling BRIZA 2018.EX BRIZA Super slim and powerful heating, cooling Briza is a climate unit with a dual personality: a Hybrid that provides comfortable heat in winter and refreshing cooling in summer. It provides

More information

ACTIVENT System. Specifications. Product code example ACTA

ACTIVENT System. Specifications. Product code example ACTA Activent is a ventilation system for supplying and distributing air. The system has been proven to function effectively in both small and large areas and is used in all types of premises ranging from offices

More information

BRIZA Brochure UK 2013

BRIZA Brochure UK 2013 BRIZA Brochure UK 2013 BRIZA Super slim and powerful heating, cooling and ventilation Briza is a climate unit with a dual personality: a Hybrid that provides comfortable heat in winter and refreshing cooling

More information

Resolair 64 and 68. Comfort air conditioning unit with highly efficient regenerative heat storage packages. AIR VOLUME FLOW: 3,900 23,100 m³/h

Resolair 64 and 68. Comfort air conditioning unit with highly efficient regenerative heat storage packages. AIR VOLUME FLOW: 3,900 23,100 m³/h Comfort air conditioning unit with highly efficient regenerative heat storage packages 68 10 01 - simplified illustration Automatically selects the most economical operating mode! 64 and 68 AIR OLUME FLOW:

More information

EURUS / EURUS-I. Conditioning your ambient, maximising your comfort.

EURUS / EURUS-I. Conditioning your ambient, maximising your comfort. EURUS / EURUS-I Centrifugal fan coils for surface mounting or recessed installation. Cooling capacities from 0,6 to 7,6 and heating capacity from 0,8 to 9. Air folw from 0 to 0 m /h. Conditioning your

More information

BASTONE (dual) fancoil Units

BASTONE (dual) fancoil Units BASTONE (dual) fancoil Units Technical information manual Western Airconditioning B.V. Tel. +31 (0) 33 247 78 00 www.western.nl 1-INTRODUCTION..3 2- WORKING CONDITION LIMITS...3 3- COANDA EFFECT 3 4- KEY

More information

EC Motor MultiZone Fan Coil Units. IXDL-Y Series l/s

EC Motor MultiZone Fan Coil Units. IXDL-Y Series l/s EC Motor MultiZone Fan Coil Units IXDL-Y Series 00 000 l/s Company Profile Temperzone Limited is a leading manufacturer and distributor of quality air conditioning and ventilation products throughout the

More information

NR series. Circular CAV air volume control terminals with system powered mechanical regulator

NR series. Circular CAV air volume control terminals with system powered mechanical regulator series Circular CAV air volume control terminals Table of contents Description Page Type designation 1 Technical data - General 2 - Specification 3 - Installation instruction 3 overview / dimensions 4-5

More information

42GW. Hydronic Cassette Fan Coil Units PRODUCT SELECTION DATA INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS EASY INSTALLATION

42GW. Hydronic Cassette Fan Coil Units PRODUCT SELECTION DATA INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS EASY INSTALLATION PRODUCT SELECTION DATA EASY INSTALLATION INSTALLATION, OPERATION AND CENTRAL AIR DIFFUSION MAINTENANCE INSTRUCTIONS LOW ENERGY CONSUMPTION IMPROVED COMFORT ELEGANT AIR INLET GRILLE EXTREMELY QUIET OPERATION

More information

LOW STATIC FAN COIL UNITS District Cooling Chilled Water Application

LOW STATIC FAN COIL UNITS District Cooling Chilled Water Application STATIC FAN COIL UNITS District Cooling Chilled Water Application CLASSIFIED INSULATION & FILTER MEDIA GFC LD Series Cooling Capacity Range 9,690 yo 46,064 BTU/HR (4 ROWS ) GFC-LD-TC-10-13 3 General Specifications

More information

air handling units YAH

air handling units YAH air handling units YAH Air Handing Units YAH Series YORK YAH series ceiling-mounted air handling units are terminal points of central air-conditioning systems. They are designed for fresh air units or

More information

CODE MODEL 1RC9020 REC PRO 90 S RC9021 REC PRO 90 S RC9022 REC PRO 90 S RC9023 REC PRO 90 S

CODE MODEL 1RC9020 REC PRO 90 S RC9021 REC PRO 90 S RC9022 REC PRO 90 S RC9023 REC PRO 90 S REC PRO 9S High efficiency Heat Recovery Units Non residential applications EFFICIENCY 9% Comply with ErP Directive 125/29/CE and EU Regulation 1253/214. Classification: Non Residential Ventilation Unit

More information

DRAFT. Technical Data OPA Ducted Three Phase Packaged Air Conditioners. 47 kw 96 kw

DRAFT. Technical Data OPA Ducted Three Phase Packaged Air Conditioners. 47 kw 96 kw DRAFT Ducted Three Phase Packaged Air Conditioners Technical Data 96 Twin System Enables Staging Extra Long Life Epoxy Coated Outdoor Coil OPTION TZT-71 Controller & Digital Scroll Compressor for close

More information

AKOR-HR NEW HIGH EFFICIENCY HEAT RECOVERY UNIT. Heat Recovery AKOR-HR. Easy maintenance. EN AKOR-HR 14/1/08 13:01 Página 599

AKOR-HR NEW HIGH EFFICIENCY HEAT RECOVERY UNIT. Heat Recovery AKOR-HR. Easy maintenance. EN AKOR-HR 14/1/08 13:01 Página 599 EN 599-604 AKOR-HR 14/1/08 13:01 Página 599 HIGH EFFICIENCY HEAT RECOVERY UNIT AKOR-HR NEW Heat Recovery unit with casing manufactured from expanded polypropylene. Outlet and inlet duct conectors Ø150.

More information

Everest XV. ErP. High Efficiency HRV Fan Unit READY