LOW STATIC FAN COIL UNITS District Cooling Chilled Water Application
|
|
- Wilfred Gaines
- 5 years ago
- Views:
Transcription
1 STATIC FAN COIL UNITS District Cooling Chilled Water Application CLASSIFIED INSULATION & FILTER MEDIA GFC LD Series Cooling Capacity Range 9,690 yo 46,064 BTU/HR (4 ROWS ) GFC-LD-TC-10-13
2
3 3
4
5 General Specifications of STATIC Chilled Water Fan Coil Units Structure: Made from 0.8 mm thick (22gauge) galvanized (G90) steel sheet. All parts in direct contact with the treated air are insulated thermally and acoustically with 6 mm thick closed c ell foam insulation. The insulation is UL listed Drain pan: Made from 0.8 mm thick galvanized (G90) steel sheet, polyester powder coated for corrosion resistance as standard. Stainless steel drain pan can be provided as an option. Drain connection is ¾ steel pipe without thread for all units. Drain pipe can be left or right side of the unit looking at the air outlet. Drain pan is extended outside the cabinet and is insulated with 6mm closed cell foam insulation Heat Exchanger: Made from 3/8 " plain copper tubes, mechanically expanded into saw type aluminium fins. Heat Exchangers are specifically designed for district cooling chilled water application by properly differentiating the coil circuits. Heat Exchangers are leak tested at 450 psi and maximum working pressure should be 250psi. Heat Exchangers are 4Rows provided with manual air vent. Headers are made from copper with brass MPT for water connection. Water connections can be left (left coil) or right (right coil) of the unit looking at the air outlet. As standard the drain and water connections are on the same side, unless otherwise specified. Fan: Fans are double inlet double width (DIDW), centrifugal type, forward curved, statically and dynamically balanced, horizontally oriented with glavanized steel impeller in galvanized steel casing. Fan Motor: Motors are of PSC type, with built-in thermal overload cut out and permanently sealed and lubricated ball bearings. Motors are provided with 5-speeds. Factory pre-selected and pre-wired to the junction are 3 speeds for high, medium and low. The selection must not be changed without consulting the factory and considering the actual operating ESP. The insulation class B and IP 23 Air Filter: The filters are factory installed aluminum type, 12.5mm thick, permanent and washable. The filter media is UL Listed The Units are constructed with special design for low height application above the false ceiling and the flanged air outlet is properly sized to reduce noise. Units are manufactured with Ceiling anchoring slots for easy fixing and leveling of the unit. The bottom panel at the fan deck side can be removed for easy access and maintenance of motor and blowers. Performance data are based on actual working conditions considering the extra pressure drop from the wet coil and aluminium filter. The Maximum face velocity (at 0 ESP and high fan speed) is below 2 m/s for low noise and low pressure drop purposes. 5
6 TECHNICAL DATA 4 ROWS COIL NOMINAL VALUES SYSTEM CURVE ESP-25 Pa at Medium Speed AIR INLET (DBT/WBT) (27.0 C/19.0 C) (80.6 F/66.2 F) WATER INLET/OUTLET (5.5 C / 14.5 C) (41.9 F/58.1 F) UNIT MODEL GFC-300-LD GFC-400-LD GFC-500-LD GFC-600-LD m 3 /h cfm AIR F m 3 /h cfm m 3 /h cfm kw btu/h kw btu/h kw btu/h kw btu/h kw btu/h kw btu/h kpa ft.w.g WATER kpa PRESSURE ft.w.g DROP kpa ft.w.g TUBE SIZE Inch/mm COPPER (3/8") / (9.53) OD FIN MATERIAL ALUMINIUM COIL DATA LENGTH mm HEIGHT mm ROWS / FPI No. 4/11 4/11 4/12 4/12 QTY No FAN TYPE FORWARD CURVED CENTRIFUGAL SIZE (DIA x W) mm 150/ / / /200 QTY No FAN MOTOR TYPE/IP/CLASS PSC / IP23 / B POWER SUP. V/PH/HZ / 1 / 50 RPM H / M / L 1150/1000/ /1150/ /1050/ /1200/1050 CAPACITOR μf MAX POWER INPUT watt F L A Amps SHAFT POWER watt INPUT POWER watt LENGTH NET WIDTH mm DIMENSIONS HEIGHT LENGTH SHIPPING WIDTH mm DIMENSIONS HEIGHT WEIGHT Net/Shipping kgr 28/33 32/38 38/44 41/48 CONNECTIONS WATER 3/4" MPT BRASS DRAIN 3/4" GI AIR FILTER TYPE 1/2" THICK, PERMANENTLY WASHABLE ALUMINIUM MEDIA NOTES: 1. DUE TO OUR CONTINUOUS IMPROVEMENT, SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE. 2. DATA ARE BASED ON WET COIL CONDITIONS. AIR F DATA REFERENCED TO STANDARD CONDITIONS 6
7 TECHNICAL DATA 4 ROWS COIL NOMINAL VALUES SYSTEM CURVE ESP-25 Pa at Medium Speed AIR INLET (DBT/WBT) (27.0 C/19.0 C) (80.6 F/66.2 F) WATER INLET/OUTLET (5.5 C / 14.5 C) (41.9 F/58.1 F) UNIT MODEL GFC-800-LD GFC-1000-LD GFC-1200-LD GFC-1400-LD m 3 /h cfm AIR F m 3 /h cfm m 3 /h cfm kw btu/h kw btu/h kw btu/h kw btu/h kw btu/h kw btu/h kpa ft.w.g WATER kpa PRESSURE ft.w.g DROP kpa ft.w.g TUBE SIZE Inch/mm COPPER (3/8") / (9.53) OD FIN MATERIAL ALUMINIUM COIL DATA LENGTH mm HEIGHT mm ROWS / FPI No. 4/12 4/11 4/11 4/12 QTY No FAN TYPE FORWARD CURVED CENTRIFUGAL SIZE (DIA x W) mm 160/200J 160/200J 160/200J 160/200J QTY No FAN MOTOR TYPE/IP/CLASS PSC / IP23 / B POWER SUP. V/PH/HZ / 1 / 50 RPM H / M / L 1300/1200/ /1050/ /1050/ /1050/930 CAPACITOR μf 5 2X5 2X5 2X5 MAX POWER INPUT watt 279 2X175 2X175 2X249 F L A Amps 1.3 2X0.82 2X0.82 2X SHAFT POWER watt INPUT POWER watt LENGTH NET WIDTH mm DIMENSIONS HEIGHT LENGTH SHIPPING WIDTH mm DIMENSIONS HEIGHT WEIGHT Net/Shipping kgr 47/54 65/73 68/75 73/81 CONNECTIONS WATER 3/4" MPT BRASS DRAIN 3/4" GI AIR FILTER TYPE 1/2" THICK, PERMANENTLY WASHABLE ALUMINIUM MEDIA NOTES: 1. DUE TO OUR CONTINUOUS IMPROVEMENT, SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE. 2. DATA ARE BASED ON WET COIL CONDITIONS. AIR F DATA REFERENCED TO STANDARD CONDITIONS 7
8 4 ROWS COIL PERFORMANCE DATA AIR INLET (DBT/WBT) (27.0 C/19.0 C) (80.6 F/66.2 F) WATER INLET/OUTLET (5.5 C / 14.5 C) (41.9 F/58.1 F) ESP - 25 pa at Medium speed UNIT MODEL GFC-300-LD GFC-400-LD GFC-500-LD GFC-600-LD m 3 /h cfm AIR F m 3 /h cfm m 3 /h cfm kw btu/h kw btu/h kw btu/h kw btu/h kw btu/h kw btu/h ESP - 0 pa AIR F ESP - 15 pa at Medium speed m 3 /h cfm m 3 /h cfm m 3 /h cfm kw btu/h kw btu/h kw btu/h kw btu/h kw btu/h kw btu/h m 3 /h cfm AIR F m 3 /h cfm m 3 /h cfm kw btu/h kw btu/h kw btu/h kw btu/h kw btu/h kw btu/h NOTE: DATA ARE BASED ON WET COIL CONDITIONS. AIR F DATA REFERENCED TO STANDARD CONDITIONS 8
9 4 ROWS COIL PERFORMANCE DATA AIR INLET (DBT/WBT) (27.0 C/19.0 C) (80.6 F/66.2 F) WATER INLET/OUTLET (5.5 C / 14.5 C) (41.9 F/58.1 F) ESP - 25 pa at Medium speed UNIT MODEL GFC-800-LD GFC-1000-LD GFC-1200-LD GFC-1400-LD m 3 /h cfm AIR F m 3 /h cfm m 3 /h cfm kw btu/h kw btu/h kw btu/h kw btu/h kw btu/h kw btu/h ESP - 0 pa AIR F ESP - 15 pa at Medium speed m 3 /h cfm m 3 /h cfm m 3 /h cfm kw btu/h kw btu/h kw btu/h kw btu/h kw btu/h kw btu/h m 3 /h cfm AIR F m 3 /h cfm m 3 /h cfm kw btu/h kw btu/h kw btu/h kw btu/h kw btu/h kw btu/h NOTE: DATA ARE BASED ON WET COIL CONDITIONS. AIR F DATA REFERENCED TO STANDARD CONDITIONS 9
10 4 ROWS COIL PERFORMANCE DATA AIR INLET (DBT/WBT) (24.4 C/17.2 C) (76 F/63 F) WATER INLET/OUTLET (5.5 C / 14.5 C) (41.9 F/58.1 F) ESP - 25 pa at Medium speed UNIT MODEL GFC-300-LD GFC-400-LD GFC-500-LD GFC-600-LD m 3 /h cfm AIR F m 3 /h cfm m 3 /h cfm kw btu/h kw btu/h kw btu/h kw btu/h kw btu/h kw btu/h ESP - 0 pa AIR F ESP - 15 pa at Medium speed m 3 /h cfm m 3 /h cfm m 3 /h cfm kw btu/h kw btu/h kw btu/h kw btu/h kw btu/h kw btu/h m 3 /h cfm AIR F m 3 /h cfm m 3 /h cfm kw btu/h kw btu/h kw btu/h kw btu/h kw btu/h kw btu/h NOTE: DATA ARE BASED ON WET COIL CONDITIONS. AIR F DATA REFERENCED TO STANDARD CONDITIONS 10
11 4 ROWS COIL PERFORMANCE DATA AIR INLET (DBT/WBT) (24.4 C/17.2 C) (76 F/63 F) WATER INLET/OUTLET (5.5 C / 14.5 C) (41.9 F/58.1 F) ESP - 25 pa at Medium speed UNIT MODEL GFC-800-LD GFC-1000-LD GFC-1200-LD GFC-1400-LD m 3 /h cfm AIR F m 3 /h cfm m 3 /h cfm kw btu/h kw btu/h kw btu/h kw btu/h kw btu/h kw btu/h ESP - 0 pa AIR F ESP - 15 pa at Medium speed m 3 /h cfm m 3 /h cfm m 3 /h cfm kw btu/h kw btu/h kw btu/h kw btu/h kw btu/h kw btu/h m 3 /h cfm AIR F m 3 /h cfm m 3 /h cfm kw btu/h kw btu/h kw btu/h kw btu/h kw btu/h kw btu/h NOTE: DATA ARE BASED ON WET COIL CONDITIONS. AIR F DATA REFERENCED TO STANDARD CONDITIONS 11
12 SOUND DATA (4 ROWS) STATIC FAN COIL UNITS (DISTRICT COOLING CHILLED WATER APPLICATION) MODEL SPEED SPECTRUM ANALYSIS SOUND PRESSURE GFC 300-LD Hz db(a) db(a) db(a) db(a) 36 GFC 400-LD GFC 500-LD GFC 600-LD GFC 800-LD GFC 1000-LD GFC 1200-LD GFC 1400-LD Hz db(a) db(a) db(a) db(a) Hz db(a) db(a) db(a) db(a) Hz db(a) db(a) db(a) db(a) Hz db(a) db(a) db(a) db(a) Hz db(a) db(a) db(a) db(a) Hz db(a) db(a) db(a) db(a) Hz db(a) db(a) db(a) db(a) 48 DATA GIVEN ARE SOUND PRESSURE LEVEL ADJUSTED FOR m FROM THE FAN COIL UNIT IN OPEN FIELD THE FAN COIL IS OPERATING AT THE FOLING CONDITIONS AIR INLET TEMPERATURE 27 0 C DB / 19 0 C WB COLD WATER TEMPERATURE C IN AND C OUT SYSTEM CURVE SO AS WE HAVE 25 pa ESP AVAILABLE AT SPEED IMPORTANT NOTICE: SOUND DATA WILL BE DIFFERENT AT DIFFERENT OPERATING CONDITIONS 12
13 DIMENSIONAL DRAWINGS GFC -300-LD GFC -400-LD 13
14 GFC-500-LD GFC -600-LD GFC -800-LD DIMENSIONAL DRAWINGS 14
15 GFC LD GFC LD GFC LD DIMENSIONAL DRAWINGS 15
16 16
17 CONVERSION FACTORS TO OBTAIN MULTIPLY BY BTU Kilo Calories BTU Watts BTU/lb kj/kg 0.43 Centimeters inches 2.54 CFM Cubic Meters Per Hour Cubic Feet 1 Liter Cubic Feet Per Minute Cubic Meters Per Minute Cubic Meters 1 Cubic Foot Cubic Meters Per Hour CFM Cubic Meters Per Hour Liters Per Second 3.57 Cubic Feet Per Min Liters Per Second Degrees Celsius Degrees Farenheit (F-32/)1.8 Feet Meters Feet Per Minute Meters Per Hour Feet Per Minute Meters Per Second Feet Per Second Meters Per Second 3.28 Fins Per Millimeter Fins Per Inch Spacing 25.4 Gallons (U.K) (IMP) 1 Gallon (U.S) Gallons (U.K) (IMP) 1 Liter Gallons (U.K)/Minute Liters Per Second Gallons (U.S) 1 Gallon (U.K) (IMP) 1.2 Gallons (U.S) 1 Liter Gallons (U.S)/Minute Liters Per Second GPM (U.S) GPM Water Flow (U.K) (IMP) 1.2 Horse Power Kilowatts (kw) Inches Meters Inches of Mercury Pa or N/m Inches of Mercury kpa Inches of Water Gauge Feet of Water Gauge (Water Pressure Drop) 12 Inches of WG Kilo Pascals (kpa) Kilo Calories Per Hour BTU Per Hour Kilo Calories Per Hour Watts Kilo Pascal Feet of Water gauge (Water Pressure Drop) 2.99 Kilo Pascal PSI (Pounds Per Square Inch) Kilo Pascals (kpa) Inches of Water Gauge (Air Pressure) Kilo Pascals (kpa) 1 Meter Water Gauge Kilograms Pounds Kilograms/Sq Cm PSI (Pounds Per Square Inch) 0.07 Kilowatts BTU Per Hour Kilowatts Horsepower Liter 1 Cubic Foot Liter 1 Cubic Meter 1000 Liters 1 Gallon (U.S) Liters 1 Gallon (U.K) (IMP) Liters Per Second CFM Liters Per Second Cubic Meters Per Hour Liters Per Second GPM Water Flow (U.S) Liters Per Second GPM Water Flow (U.K) IMP Meter WG Kilo Pascals (kpa) Meters Feet Meters Inches Meters Per Hour Feet Per Minute Meters Per Hour Meters Per Second Millimeters Inches 25.4 Pascals Inches of Water Gauge (Air Pressure) Pounds 1 Kilogram Pounds Per Square Inch Kilograms Per Square CM PSI BAR 14.5 PSI ATM PSI kpa or N 2 /m Square Feet Square Meters Square Meters Square Feet Tons Cooling Kilowatts W/ft 2 W/m Watts BTU Per Hour Watts Kilo Calories EQUIVALENTS 3/8 Inch Equals 9.53 Millimeters (mm) 1/2 Inch Eqauls Millimeters (mm) 5/8 Inch Equals Millimeters (mm) 3/4 Inch Equals Millimeters (mm) 1 Inch Equals Millimeters (mm) 17
18
19
20 P.O. Box : 28131, ICAD-1, Mussafah, Abu Dhabi UAE Tel : Fax : info@gami.ae Website: Specifications in this catalogue are subject to change without notice in order that may bring latest innovations to the customers. GULF AIRCONDITIONING MANUFACTURING INDUSTRIES L.L.C.
HIGH STATIC FAN COIL UNITS
STATIC FAN COI UNITS District Cooling Chilled Water Application TECNICA CATAOGUE (DUCTED TYPE) GFC - D SERIES COOING CAPACITY RANGE: 10,407 TO 66,329 BTU/R CASSIFIED INSUATION & FITER EDIA GFC-D-TC-10-13
More informationDECORATIVE FAN COIL UNIT DECORATIVE FAN COIL UNIT SPECIFICATIONS
DECORATIVE FAN COIL SPECIFICATIONS UNIT CABINET Single skin or double skin casing (inner perforated sheet or flat sheet) made of powder coated galvanized steel assembled in aluminum extrusion profiles,
More informationAddress: VTS Clima L.L.C.
Address: VTS Clima L.L.C. Business Bay, Churchill Tower, Office 2409, P.O.Box#76849 Dubai, UAE phone: +971 (4) 443 91 20 fax: +971 (4) 443 96 20 e-mail: dubai@vtsgroup.com www.uae.vtsgroup.com Index VTS
More information36CWA4-HW 4-Pipe Chilled & Hot Water Air Handler (120V) 4-Pipe Heat & Cool Fan Coil 36,000 BTUH
36CWA4-HW 4-Pipe Chilled & Hot Air Handler (120V) 4-Pipe Heat & Cool Fan Coil 36,000 BTUH Rev. 1.2 HVAC Guide Specifications Chilled & Hot Multi-Position Fan Coil 4-Pipe Nominal Size: 36,000 BTUH Multiaqua
More information48CWA2-00 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 48,000 BTUH
48CWA2-00 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 48,000 BTUH Rev. 1.3 HVAC Guide Specifications Chilled or Hot Water with Optional Electric Heat Multi-Position
More information24CWA4-HW 4-Pipe Chilled & Hot Water Air Handler (120V)
24CWA4-HW 4-Pipe Chilled & Hot Air Handler (120V) 4-Pipe Heat & Cool Fan Coil 24,000 BTUH Rev. 1.2 HVAC Guide Specifications Chilled & Hot Multi-Position Fan Coil 4-Pipe Nominal Size: 24,000 BTUH Multiaqua
More informationFan Coil Units POWERED BY KLIMAK ITALY
Fan Coil Units POWERED BY KLIMAK ITALY Index Chilled Water Fan Coil Unit Decorative Fan Coil... Concealed Ducted Fan Coil Unit (Low ESP)...11 Concealed Ducted Fan Coil Unit (Medium ESP)...1 Concealed
More informationMODULAR AIR HANDLING UNITS GAH SERIES
MODULAR AIR HANDLING UNITS GAH SERIES 15 Models with Air Flows from 2,250 Cu.m/hr upto 77,800 Cu.m/hr Suitable for both Standard and District Cooling Applications GAH-TC-10-13 CONTENTS Design 2 Various
More informationChilled Water FCU. Horizontal Fan Coil 50hz CFM. A Series.
Chilled Water FCU A Series 3-25 CFM Horizontal Fan Coil 5hz www.windind.com CONTENTS GENERAL CONSTRUCTION... 3 MODEL NUMBER NOMENCLA TURE... 4 DIMENSIONS... 5 FAN PERFORMANCE DATA... 7 GENERAL SPECIFICATIONS...
More informationMH1WC4W-08-1-B Chilled/Hot Water 1-Way Cassette Fan Coil
MH1WC4W-08-1-B Chilled/Hot Water 1-Way Cassette Fan Coil 4-Pipe Heat / Cool Fan Coil 24,000 BTUH Rev. 1.11 HVAC Guide Specifications Chilled and Hot Water Cassette Fan Coil 4-Pipe Nominal Size: 24,000
More informationMHWW-24-H-1 Chilled/Hot Water Hi-Wall Fan Coil. Heat / Cool Fan Coil 24,000 BTUH. Rev. 1.3
MHWW-24-H-1 Chilled/Hot Water Hi-Wall Fan Coil Heat / Cool Fan Coil 24,000 BTUH Rev. 1.3 HVAC Guide Specifications Chilled and Hot Water Hi-Wall Fan Coil 2-Pipe Nominal Size: 24,000 BTUH Multiaqua Model
More informationTechnical Sales Guide # 040 YDFC 0 1 Page 2
17-18 Technical Sales Guide # 040 YDFC 0 1 Page 2 Technical Sales Guide # 040 YDFC 0 1 Page 3 York China Fan Coil Unit Model Type ST - Standard DC - District Cooling Number of rows 3: 3 Rows 4: 4 Rows
More informationA Division of Nailor International Inc. ECONOMY AIR HANDLERS
A Division of Nailor International Inc. MODEL : ECONOMY AIR HANDLERS Thermal Model Standard Specification MODEL 800-4000 CFM AIR HANDLERS Description Model air handlers are designed for efficient and economical
More informationGuide Specifications. General. Casing. Coil/Drain pan. Fan/Motor
Guide Specifications General CR-A series ducted concealed chilled water fan coil units have an air flow range from 45 to 3060 cubic meters per hour with a capacity range from kw up to 9 kw. The CR-A series
More informationThe World Leading Air-conditioning Company
The World Leading Air-conditioning Company Table of Contents DESCRIPTIONS Model Number Nomenclature Features & Benefits Physical Dimension Fan Performance Curve (4 Row) - 40LMA024 with AC Motor - 40LMA040
More informationPrecision Cooling For Business-Critical Continuity. Liebert CW. System Design Manual kW, 50 & 60Hz
Precision Cooling For Business-Critical Continuity Liebert CW System Design Manual - 26-181kW, 50 & 60Hz TABLE OF CONTENTS LIEBERT CW MODEL NUMBER NOMENCLATURE....................................1 1.0
More information42CET/ 42CED Series Chilled Water Fan Coil Unit Furred-in Ceiling Model 300 to 1400 cfm Electric heater option
42CET/ 42CED Series Chilled Water Fan Coil Unit Furred-in Ceiling Model 0 to 10 cfm Electric heater option 42DC/ 42DCD Series Chilled Water Fan Coil Unit Furred-in Ceiling Model 0 to 00 cfm Electric heater
More informationHBC SERIES-PSC MOTOR HBCX SERIES-ECM MOTOR
PRODUCT SPECIFICATIONS *HBC(X) *PHBC(X) *RHBC(X) *CHBC(X) Chilled Water/Hot Water 2-pipe/4-Pipe HBC SERIES- HBCX SERIES-ECM MOTOR Ceiling Concealed Horizontal -1 CFM Ceiling Concealed Ceiling Recessed
More informationINTRODUCTION CP 06 F C - A 4 L - F GENERAL DESCRIPTION DESIGN PARAMETER DUCTED CONCEALED WITH PLENUM. F - c/w Filter
INTRODUCTION GENERL DESCRIPTION Ducted Direct Drive Fan Coil ir Conditioners are designed to fulfill the air conditioning requirements of today s living. These requirements include dependable trouble-free
More informationCommercial Blower Coil Air Handlers
Commercial Blower Coil Air Handlers MODEL : BDH(V)B - 048, 065, 080 7400 CMH - 14300 CMH 30 kw - 125 kw BCXB-PRC001-E4 Contents Model Number Description General Specification Standard Features Unit Configuration
More informationCFFWA Chilled/Hot Water Universal Mount Fan Coil 2-Pipe Heat / Cool Fan Coil 12,000-60,000 BTUH
CFFWA Chilled/Hot Water Universal Mount Fan Coil 2-Pipe Heat / Cool Fan Coil 12,000-60,000 BTUH 207 CFFWA NOMENCLATURE BREAKDOWN 2-Pipe Heat/Cool Universal Mount Fan Coil CFFWA- XX - 1 - U 2-Pipe Heat/Cool
More informationCHILLED WATER DUCTED FAN COIL
SD CHILLED WATER DUCTED AN A Series B Series (Double Skin) General abricated with a rigid galvanized steel casing. The DIDW centrifugal fans have balanced, galvanized steel, and forward curved blades.
More informationFCVC Series VERTICAL FAN COILS
VERTICAL FAN COILS The FCVC is designed for concealed, wall mounted installations with flexible heating/ cooling loads and minimal duct requirements. With a variety of options, such as fiber free insulation,
More informationCHILLED WATER FAN-COIL UNITS
40LM - PRODUCT DATA DIGEST CHILLED WATER FAN-COIL UNITS QUALITY SYSTEM MALAYSIA MS ISO 001 REG. NO: AR 023 1 Any room, every room flexibility in an air conditioning system FEATURES: Chilled Water Furred-in
More informationChiller, Close control and Water terminals. Air Conditioning. Light Commercial, Commercial and Industrial
Chiller, Close control and Water terminals Air Conditioning Light Commercial, Commercial and Industrial Water Terminals 133 Water Terminals Fan coils & Cassette Centrifugal fan-coil SYSCOIL Ductable fan-coil
More informationHigh Static Fan Coil Units YDFC
Static Fan Coil Units YDFC Contents contents Product information...3 Nomenclature & features...4 Features & benefits...4 Product details...5 Technical specifications...6 Unit dimensions ST type...7 Unit
More informationPHCD-Series. Catalog
PCD-Series Catalog odel: PCD Introduction PCD fan coil unit is designed for a fully concealed ceiling installation. The external static pressure(esp) is up to 75Pa. Owing to its low static and low noise,
More informationDIRECT-DRIVE BLOWER FAN COIL AIR CONDITIONER ENGINEERING GUIDE
DIRECT-DRIVE BLOWER FAN COIL AIR CONDITIONER ENGINEERING GUIDE Model: YSHW-DD 00784VIP Introduction YORK DIRECT DRIVE FAN COIL UNITS The YORK Fan Coil Unit is designed for many exposed and concealed applications.
More informationHBC SERIES-PSC MOTOR HBCX SERIES-ECM MOTOR
PRODUCT SPECIFICATIONS *HBC(X) *PHBC(X) *RHBC(X) *CHBC(X) Chilled Water/Hot Water 2-pipe/4-Pipe HBC SERIES- HBCX SERIES-ECM MOTOR Ceiling Concealed Horizontal -1 CFM Ceiling Concealed Ceiling Recessed
More information42C/D SERIES Ducted Chilled Water Fan Coil Unit With District Cooling Application
42C/D SERIES Ducted Chilled Water Fan Coil Unit With District Cooling Application MAXIMIZING PERFORMANCE, ENERGY SAVINGS & COMFORT MODEL NUMBER NOMENCLATURE 4 2 C E T 0 0 3 4 7 0 1 2 5 42 series CISB Code
More informationVertical Floor Fan Coil Unit (Model FW)
Technical Bulletin Issue Date March 24, 2005 Vertical Floor Fan Coil Unit (Model FW) Figure 1: Model FWX Vertical Exposed Model FW Vertical Floor fan coil units are designed to maximize flexibility of
More informationProduct Data. FS3QX Slim Line Ducted Fan Coil With Plenum Sizes 018 thru 060 SLIM LINE DUCTED FAN COIL WITH PLENUM ON/OFF DISPLAY TEMP
FS3QX Slim Line Ducted Fan Coil With Plenum Sizes 018 thru 060 Product Data A114 SLIM LINE DUCTED FAN COIL WITH PLENUM Installation Ease S Factory installed 24 volt transformer and relay S High and low
More informationSPECIFICATIONS AND DESIGN ARE SUBJECT TO CHANGE WITHOUT PRIOR NOTICE. EDITION 11
AIR HANDLING UNIT (DOUBLE SKIN) MODEL: DS-CW/DX-AHU-H (Chilled Water or Direct Expansion) CAPACITY: 3.3 to 125 Nominal Tons 39,000 to 1,500,000 BtuH 11.4 to 439.5 KW 1,300 to 50,000 CFM Benefits Horizontal
More information42HS Fan Coil Unit (High Static Pressure)
42S Fan Coil Unit (igh Static Pressure) Air Volume: 1360~3400m3/h Turn To The Experts Founded by the inventor of modern air conditioning, Carrier is the world s leader in high-technology heating, air-conditioning
More informationGENERAL ELECTRIC CONCEALED CHILLED WATER FAN COIL UNITS
GENERAL ELECTRIC CONCEALED CHILLED WATER FAN COIL UNITS ACWL Series ACWL0 thru ACWL4 00 CFM thru 400 CFM GE_ACWL_series.indd 3// : PM CONTENTS Model decoding 3 Unit features 3 Standard specifications 3-4
More informationtechnical sales guide - 60Hz Ducted Split Units HIGH AMBIENT OPERATION 52 UPTO
technical sales guide - 60Hz Taurus R Ducted Split Units UPTO HIGH AMBIENT OPERATION 52 O C Page CONTENTS Nomenclature.. 2 Description. 3 Features.. 3 Product Data. 4 Condensing Unit Cooling Performance
More informationProduct Data. Features/Benefits. 42BH System Fan Coil. 800 to 4000 Cfm
Product Data 42BH System Fan Coil 800 to 4000 Cfm Satisfy All Your Design Requirements with Carrier s Versatile 42BH Fan Coil Unit A selection of 6 sizes covers capacities from 800 to 4000 cfm Choice of
More informationËÕߪ Õ» ç åé. 50BY/BL Series. Single-Package Cooling Units 90, ,500 BTUH. World's No.1 Air Conditioning Expert
ËÕߪ Õ» ç åé BY/BL Series Single-Package Cooling Units 90,000-895,0 BTUH World's No.1 Air Conditioning Expert www.carrier.co.th BY/BL Series Features Commercial or Industrial Applications Single- or Multiple-Unit
More informationPrepared By : Checked By : Approved By : Page 1 out of 6
Software Name Carrier AHU - Version 1.0, Patch R1.1X UNIT MODEL GENERAL SPECIFICATIONS GENERAL LOCATION / WEIGHT UNIT DIMENSION Configuration : Quick Selection Wizard Unit Orientation : Horizontal Box
More informationVertical Hi-Rise Fan Coil Unit (Model FS)
Technical Bulletin Issue Date March 1, 2005 Vertical Hi-Rise Fan Coil Unit (Model FS) Model FS Vertical Hi-Rise fan coil units are designed to maximize flexibility of selection and installation. The units
More informationIndoor Air Handling Unit (Model AMI)
Technical Bulletin Issue Date December 15, 2004 Indoor Air Handling Unit (Model AMI) Model AMI Indoor Air Handling Units are designed to maximize flexibility of selection and installation, enabling you
More informationDAIKIN INDUSTRIES, LTD. Ceiling Concealed Chilled Water Fan Coil Unit (50Hz/60Hz)
Engineering Data ED-FWW-201501 Ceiling Concealed Chilled Water Fan Coil Unit (50Hz/60Hz) Models: FWW200 FWW300 FWW400 FWW600 FWW800 FWW1000 FWW1200 FWW1400 FWW1600 FWW1800 Air Flow: 360-3020m 3 /h DAIKIN
More informationHigh Performance Fan Coils FCHG Genesis Series Horizontal
Dimensional Data 5 7 /8 (150) D 14 (356) 2 (51) Diverter - Slides Into Discharge Ductwork Optional: Second Drain Pan Connection E Coil Section X Dimensional Data - IP (in.) / SI [mm] Unit Fan Outlet Duct
More informationSINGLE PACKAGE AIR CONDITIONING WATER COOLED
MODELS: CU060-300 5-25 TONS VERTICAL SINGLE PACKAGE AIR CONDITIONING WATER COOLED MODELS: CH060-5-10 TONS HORIZONTAL FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE TABLE OF CONTENTS
More informationAnd ASEAN EAW WATER) Head. Office : Ruko
The Winner of INDONESIA ENERGY AWARD 2013 And ASEAN ENERGY AWARD 2004 2012 AIR HANDLING UNIT (AHU CHILLED WATER) 1.600 M³/ /hr. 52.000 M³/hr EAW CHILLED WATER PT. METROPOLITAN BAYU INDUSTRI A member of
More informationTECHNICAL GUIDE R410a SPLIT SYSTEM 1.5 to 5.0 NOMINAL TONS
Version.MDT-2016.T3.103 TECHNICAL GUIDE R410a SPLIT SYSTEM 1.5 to 5.0 NOMINAL TONS FEATURES AND BENEFITS COMPRESSOR: Compressors are protected with internal temperature and current overloads. An internal
More informationGENERAL ELECTRIC FAN COIL UNITS
GENERAL ELECTRIC FAN COIL S Chilled Water System CFM thru CFM GE_AWHE_series.indd 3/6/ 3:3 PM GE_AWHE_series.indd 3/6/ 3:3 PM CONTENTS Outstanding features 4 Model decoding 5 A pplications 5 Physical data
More informationHighline 260i EC Waterside Fan Coil Unit
Features: Electronically Commutated (EC) fan motor Specific Fan Power of 0.16 to 0.34 at NR Insignificant fan heat gain Designed to operate below NR at External Static Pressures of up to 50Pa Variable
More informationDuctable Modular Fan Coil Unit VPX. Technical Brochure TM VPX-W.2GB Date : May 2004 Supersedes : TM VPX-W.1GB/08.03
Ductable Modular Fan Coil Unit VPX Technical Brochure TM VPX-W.2GB Date : May 2004 Supersedes : TM VPX-W.1GB/08.03 Design Features Presentation The VPX fan coil unit has been specially designed to meet
More information5 to 100 Ton Capacity Custom Capacities Available
COIL COMPANY 5 to 100 Ton Capacity Custom Capacities Available LRC s remote Air Cooled Fluid Coolers (AFC) provide optimum heat transfer efficiency and are manufactured for years of dependable service.
More informationFAN POWERED SERIES FCI-600 CONSTANT VOLUME FAN TERMINAL UNIT SPECIFIABLE FEATURES
FAN TERMINAL UNIT SPECIFIABLE FEATURES Galvanized steel casing, mechanically sealed for low leakage construction NEMA TYPE 1 rated hinged control enclosure with standoff to prevent penetration of casing
More informationAPARTMENT FAN COILS AVAILABLE WITH FACTORY INSTALLED 5, 7, & 11 kw ELECTRIC HEAT, or NO HEAT R-410A and R-22 SYSTEMS
FSA Product Specifications APARTMENT FAN COILS AVAILABLE WITH FACTORY INSTALLED 5, 7, & 11 kw ELECTRIC HEAT, or NO HEAT R-410A and R-22 SYSTEMS 1½ THRU 3 TONS FEATURES TXV metering device factory installed
More informationFCX TECHNICAL BOOKLET
FAN COIL FCX US FCX USPO This document is based on AERMEC s FCX US, USP, USPO Technical and Installa on Booklet but reflects only those sizes and configura ons currently offered by Phoenix Energy Supply.
More informationNEW Acoustic In-Line Fans (ACQ)
NEW Acoustic In-Line Fans (ACQ) Acoustically treated housing, Class O rated, sandwich construction selected for maximum noise absorption Motors protected to IP44 Motor insulation Class B Maximum operating
More information42CHS-W Series. Chilled Water Fan Coil Unit Ceiling Concealed - Duct Type. Nominal: 400-2,000 CFM. World's No.1 Air Conditioning Expert QMS 001
42CHS-W Series Chilled Water Fan Coil Unit Ceiling Concealed - Duct Type Nominal: 400-2,000 CFM QMS 001 World's No.1 Air Conditioning Expert www.carrier.co.th 42CHS-W Series Furred-in ceiling model 400-2000
More informationLK-FCTB August 2010 (Replaces LK-FCTB,April 2007) FPO. Direct Drive Fluid Coolers Technical Guide. Models PFG & RF6
LK-FCTB August 010 (Replaces LK-FCTB,April 007) FPO Direct Drive Fluid Coolers Technical Guide Models PFG & Table of Contents Overview...................................................................................
More informationChassis Access Fans Motors Speed Control Coils The Condensate Tray Insulation Spigots Controls Enclosure Control Valves Filters Rev A
Chassis panelwork is all In House manufactured from nominally 1.2mm Galvanised steel. Where at all possible, flanges are formed inward facing to prevent exposure to bare metal edges. Sufficient forms and
More informationCENTRIFUGAL FAN COIL UNIT VCE
CENTRIFUGAL FAN COIL UNIT VCE 0,51 kw 11,00 kw 0,85 kw 23,75 kw 129 m 3 /h 2003 m 3 /h VCE DESIGN QUALITY COMFORTRELIABILITY 3VERSION12 SIZE DESIGN VCEx0 vertical with cabinet Air intake: bottom vertical
More informationAPARTMENT FAN COILS AVAILABLE WITH FACTORY INSTALLED 5, 7, & 11 kw ELECTRIC HEAT, or NO HEAT R -22 SYSTEMS
COMMERCIAL FSA Product Specifications APARTMENT FAN COILS AVAILABLE WITH FACTORY INSTALLED 5, 7, & 11 kw ELECTRIC HEAT, or NO HEAT R -22 SYSTEMS 1½ THRU 3 TONS FEATURES S TXV metering device factory installed
More informationBAC / BHC Product Specifications
COMMERCIAL AIR HANDLERS (3 PHASE) 6 to 20 TON / Product Specifications REFRIGERATION CIRCUIT Standard factory-installed thermostatic expansion valves (TXVs) on units; units include TXVs and check valves
More informationLow Static Pressure Duct(V shape evaporator)
Low Static Pressure Duct (V shape evaporator) 1. Features... 116 2. Specifications... 118 3. Dimensions... 121 4. Service Spaces... 123 5. Piping Diagrams... 124 7.Fan Performance... 126 8.Capacity Tables...
More informationCeiling Concealed Chilled Water Fan Coil Unit
Technical Manual MODELS: ACW200 ACW300 ACW400 ACW600 ACW800 ACW1000 ACW1200 Air Flow: 112~2040 m 3 /h ACW - C/F/H - 2009-001 Ceiling Concealed Chilled Water Fan Coil Unit Contents Nomenclature... 2 Features...
More informationFan coil units. HFCE, HFXE, VFCE, VFXE series Sizes 03 to to 3400 m3/h UNT-PRC007-E4
Fan coil units HFCE, HFXE, VFCE, VFXE series Sizes 03 to 20-300 to 3400 m3/h 2012 Trane Contents Features and Benefits 4 Model Nomenclature 5 Performance Data 7 Capacities 9 Dimensional data 19 Typical
More informationBAC / BHC SERIES 6 to 20 Ton Air Handlers
/ SERIES 6 to 20 Ton Air Handlers COMMERCIAL SPLIT SYSTEM AIR HANDLER FEATURES CONSTRUCTION Die-formed galvanizedsteel casingsprovide durabilityand structuralintegrity. HIGH STATIC DESIGN High static design
More informationProduct Data. 42D Ducted Fan Coil Air Conditioners cfm
Product Data 42D Ducted Fan Coil Air Conditioners 600-2000 cfm Carrier s 42D series ducted fan coil units offer design and equipment location flexibility Choice of 5 models, each available in 8 sizes For
More informationDriving and Connecting Globally. Fan Coil Unit. Model : PHW-K Size : 510CMH~2720CMH. Made in Taiwan
Driving and Connecting Globally Fan Coil Unit : PHW-K Size : 510CMH~2720CMH Made in Taiwan Features Superior low-height design. Stainless steel drain pan for condensate and corrosion protection. Flexibe-reverse
More informationHigh Static Pressure Duct Fan Coil Unit
MCAC-KTSM-2012-03 High static pressure ducted FCU High Static Pressure Duct Fan Coil Unit 1. Introduction... 2 2. Nomenclature... 2 3. Product Schedule... 3 4. External Appearance... 3 5. Features... 4
More informationComplete HVAC Capability
Air Handling Units Brochure 1110 January 2006 Complete HVAC Capability MEA Horizontal Draw-Thru to Size 65 Vertical Draw-Thru to Size 50 1000 to 60,000 CFM Forward Curved or Airfoil Wheels Inlet Vane Option
More informationPHB SERIES 7-1/2 and 10 TON
PHB SERIES 7-1/2 and 10 TON COMMERCIAL SINGLE PACKAGE HEAT PUMPS COMMERCIAL PACKAGE HEAT PUMP FEATURES Representative photo only, some models may vary in appearance. Rated in accordance with ARI Standard
More informationBAC / BHC SERIES 6 to 20 Ton Air Handlers
/ SERIES 6 to 20 Ton Air Handlers COMMERCIAL SPLIT SYSTEM AIR HANDLER FEATURES CONSTRUCTION Die-formed galvanizedsteel casingsprovide durabilityand structuralintegrity. HIGH STATIC DESIGN High static design
More informationThe Premium Quality Fan Coil Units for Horizontal Application Hydronic or Electric Heat
Producing Quality Heating & Cooling Equipment For Over 50 Years CEA SERIES CEILING EPOSED HORIZONTAL FAN COIL UNITS The Premium Quality Fan Coil Units for Horizontal Application Hydronic or Electric Heat
More information40LAS-W Series. 40LAS-W Series. 40LAS Series ITEM NO. 492X0013
40LAS-W Series 40LAS-W Series 40LAS Series ITEM NO. 492X0013 Physical Data Description Commercial Air-Cooled Condensing Unit Packaged Chilled Fan Coil Unit Model 40RR010 40RR015 40RR020 40RR025 40RR030
More informationMGE4 FEATURES REFRIGERANT SYSTEM HEAT EXCHANGER CABINET BLOWER
GAS HEATING / ELECTRIC COOLING PACKAGED UNITS FORM NO. -100 (07/2017) FEATURES Up to 10.0 EER cooling efficiency Less than 2% cabinet air leakage Completely self-contained heating and cooling package No
More informationFluid Cooling Mobile AOHM / AOVHM Series
Fluid Cooling Mobile Series 0916 Performance Notes AO/AOVH Series with hydraulic motor Adjustable louvers (manual) High heat removal Heavy duty construction Wide flow range Heat removal up to 210,000 BTU/HR
More informationD M S 760 C01 A A 1 1
CONTENTS Description Features Options Available Selection Method Product Data Cooling Performance Data (85 F Ambient Cooling Performance Data (95 F Ambient) Cooling Performance Data (105 F Ambient)..............................
More informationIf center column value is F, the C equivalent is to the left. If center column value is C, the F equivalent is to the right.
-40.00-40 -40.0-39.44-39 -38.2-38.89-38 -36.4-38.33-37 -34.6-37.78-36 -32.8-37.22-35 -31.0-36.67-34 -29.2-36.11-33 -27.4-35.56-32 -25.6-35.00-31 -23.8-34.44-30 -22.0-33.89-29 -20.2-33.33-28 -18.4-32.78-27
More informationSPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H2CA300, 360, 480 & THRU 50 NOMINAL TONS
550.13-TG1Y(98) SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS HCA300, 360, 80 & 600 5 THRU 50 NOMINAL TONS HCA80 DESCRIPTION These units are completely assembled, piped and wired at the factory to provide one-piece
More informationHi-Performance Series Fan Coil Technical Catalog
Hi-Performance Series Fan Coil Technical Catalog HYB Horizontal Hideaway Furred-in with galvanized finish for ducted/high static applications in drop-ceilings or over-closets. (600-2000 CFM) HGC Horizontal
More informationVERTICAL SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING WITH HOT WATER OR ELECTRIC HEAT
VERTICAL SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING WITH HOT WATER OR ELECTRIC HEAT SIZES FROM 600 TO 4,000 All Technical Specifications are Subject to Change without Notice.
More informationPA95 12 SEER FEATURES 2 THRU 4 TON SINGLE PACKAGE
PACKAGE AIR CONDITIONER PA95 12 SEER C 2 THRU 4 TON SINGLE PACKAGE FEATURES CONSTRUCTED FOR DURABILITY All panels made from galvanized steel pre--coated inside and out -- using a polyester top coat, on
More informationBHH Product Specifications
BHH Product Specifications HORIZONTAL BELT DRIVE DIRECT EXPANSION BLOWER COIL UNITS ALL S 3, 4, and 5 Ton 208/230 3 60 and 460 3 60 supply voltage Units are ETL listed to U.S. and Canadian safety standards
More informationCHP
Packaged Unit Heat Pump CHP16-024-030-036-048-060 2-5 Ton Cooling 23,000-57,500 Btuh Heating 12,800-85,300 Btuh (5-25 kw) Optional Electric Heating FEATURES Designed for outdoor rooftop or ground level
More informationMAJOR 2 NCH. Ductable units. High pressure and high capacity ductable units RANGE NCH Y NCH NCH I COADIS COMBI. Motor optional
Y + U I COADIS COMBI High pressure and high ductable units Motor optional is a non independent air conditioning terminal unit for heating and cooling offices and hotels. With reduced dimensions and designed
More informationV33B High Efficiency 360 Cassette Indoor Models - 60HZ
PRODUCT SPECIFICATIONS Low-sound, high efficiency cassette, encased in galvanized steel offers 360 airflow for immediate, equal distribution of wide-range cooling and heating. Cassette has motor-driven
More informationVHIA High-Static Ducted Indoor Units - 60HZ
PRODUCT SPECIFICATIONS Compact design for limited space requirements. Installs out of sight between the drop ceiling and ceiling slab with ducted distribution to the indoor space. All models have three-stage
More informationMEDIUM SILHOUETTE UNIT COOLERS AIR AND ELECTRIC DEFROST MODELS
1 Catalog KM-MCD-0818A Replaces KM-CSA-101A, KM-DSA-101A, KM-MSA-1213A, KM-CSE-101A and KM-MSE-101A DSA, CSA, MSA, CSE, AND MSE SERIES MEDIUM SILHOUETTE UNIT COOLERS AIR AND ELECTRIC DEFROST MODELS MEDIUM
More informationSquare Mixed Flow Fans (MFQ)
Square Mixed Flow Fans (MFQ) Features and Benefits Motors protected to IP44 Motor insulation Class B Maximum operating temperature +40 C Standard Thermal Overload Protection Sizes 400 to 500 3 phase are
More informationV33A Standard/High Efficiency 360 Cassette Indoor Models - 60HZ
PRODUCT SPECIFICATIONS Low-sound, standard or high efficiency cassette, encased in galvanized steel offers 360 airflow for immediate, equal distribution of wide-range cooling and heating. Cassette has
More informationFans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Water terminals SYSCOIL. Centrifugal fan coil units
Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Water terminals SYSCOIL Centrifugal fan coil units SYSCOIL Fan coil units Compact, slim fan coil units. Available
More information42CLS-W Series Chilled Water Fan Coil Unit Ceiling Concealed - Duct Type Nominal: 400-2,000 CFM
42CLS-W Series Fan Coil Unit Ceiling Concealed - Duct Type Nominal: 400-2,000 CFM World's No.1 Air Conditioning Expert www.carrier.co.th 42CLS-W Series Furred-in ceiling model 400-0 cfm The low silhouette
More informationPackage Air Conditioners
MODEL: RACA14 Package Air Conditioners FORM NO. SSC-969 REV. 1 Sure Comfort RACA14 Package Air Conditioners RACA14 14 SEER Nominal Sizes 2-5 Tons [7.0-17.6 kw] Proper sizing and installation of equipment
More information50 Hz AIR - COOLED SPLIT SYSTEM. Products That Perform...By People Who Care AIR CONDITIONERS WITH SCROLL COMPRESSORS
R FORM NO: MS0305F Products That Perform...By People Who Care AIR - COOLED SPLIT SYSTEM AIR CONDITIONERS WITH SCROLL COMPRESSORS 50 Hz COOLING CAPACITY- 60 MBH TO 1360 MBH ACCS SERIES HEB-D, EB-D SERIES
More informationMEDIUM PROFILE UNIT COOLERS Technical Guide. Models HMA Air Defrost HME/HML Electric Defrost HMG/HMF Hot Gas Defrost.
CH-MPTB June 2015 Replaces CH-MPTB Nov 2010 MEDIUM PROFILE UNIT COOLERS Technical Guide s HMA Air Defrost HME/HML Electric Defrost HMG/HMF Hot Gas Defrost heatcraftrpd.com Table of Contents Nomenclature...2
More informationODYSSEY Product Catalogue Light Commercial Split System 5-20 Tons TTA/TTH/TWE Models 50 Hz
ODYSSEY Product Catalogue Light Commercial Split System 5-20 Tons TTA/TTH/TWE Models 50 Hz Condensing Models TTK 060 KD TTA 075 RD TTA 100 RD TTA 120 RD TTA 150 RD TTA 180 RD TTA 200 RD TTA 240 RD Air
More informationP6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6, 7½ and 10 Ton Packaged Electric Cooling Units EER Commercial System Units
TECHNICAL SPECIFICATIONS P6SP Series Rev A 6, 7½ and 10 Ton Packaged Electric Cooling Units 11.2 EER Commercial System Units These units are designed specifically for retrofit applications and compatibility
More informationBVX SERIES VERTICAL DIRECT EXPANSION BLOWER COIL UNITS
BVX SERIES VERTICAL DIRECT EXPANSION BLOWER COIL UNITS MAGIC AIRE BVX SERIES FAN COILS ARE ETLC LISTED IN ACCORDANCE WITH UL 1995 AND ARE ASSEMBLED TO ORDER FOR COMPETITIVE DELIVERY. UNITED ELECTRIC COMPANY,
More informationS5BP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS
TECHNICAL SPECIFICATIONS S5BP Series Split System Air Conditioner 71/2 Ton Energy Star rated at 11.7 EER and 11.8 IEER 10 Ton rated at 11.2 EER and 11.5 IEER R-410A Refrigerant The S5BP Series of air conditioners
More informationDIRECT EXPANSION COMMERCIAL PACKAGED AIR HANDLING UNITS, 6 25 TONS
Product Specifications DIRECT EXPANSION COMMERCIAL PACKAGED AIR HANDLING UNITS, 6 25 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE Multi position design for horizontal or vertical installation without
More informationCeiling Concealed Series FDMRN-AV1K. 50Hz. Preliminary
Ceiling Concealed Series FDMRN-AV1K 50Hz Nomenclature Main Benefits Engineering and Physical Data Electrical Data Capacity Tables Outline and Dimensions Electrical Connection Refrigerant Piping Nomenclature
More informationMEDIUM PROFILE UNIT COOLERS Technical Guide
BN-MPTB August 2016 Replaces BN-MPTB, June 2015 MEDIUM PROFILE UNIT COOLERS Technical Guide s BMA Air Defrost BME/BML Electric Defrost BMG/BMF Hot Gas Defrost heatcraftrpd.com Table of Contents Nomenclature...2
More information