1 HANDLERS LTD AHPHX Compact Heat Recovery Air Handling Unit 1262 Acoustic Testing Laboratory College of Science & Technology BIM & REVIT Engineering Solutions

2 The Company Air Handlers has been trading since May 1989, and has just celebrated 25 years in business in The Company operates from its 60,000 Sq Ft Factory in Salford Quays which was purpose built in year Product Development... The Company is continually updating its products to comply with changing energy saving technologies, so the introduction of the AHPHX Compact Range of air handling units is based on changes in specific Fan power and heat recovery legislation adopting higher energy saving technology. Compliance... The AHPHX air handling units comply with BS EN 1886 Class L2 Construction Standards. Air handling unit construction and ErP European Directive 2018 for energy recovery efficiencies. Acoustic Performance... Extensive acoustic testing of casework construction has been carried out at both the companies testing facilities, and Salford University Acoustic Testing Laboratory. Acoustic tests were carried out on twenty double skin, composite panel/frame systems, eight different triple and quadruple skin composite panel/frame systems, to BS. EN ISO (2010) which have all been certified as UKAS accredited Acoustic Testing Laboratory College of Science & Technology 2

3 Location Bag Filters AHPHX Compact Package Heat Reclaim Air Handling Units are normally located internally in plantrooms, external to the building or on the roof. Construction Frame Insulated extruded anodised aluminium pentapost sections with solid die cast mechanical fit corners are used to build each frame. The frame is acoustically insulated to prevent noise leakage. Panels Panels are flush fitted into the frame and air sealed with neoprene gaskets. A range of acoustically insulated panels are available to meet the sound reduction required in the space. Access Panels All access panels will be flush mounted in the frame, and constructed as the fixed panels. Fan and control panel access panels will be lockable. Quick release, other access panels will have multi directional handles. Heat Recovery AHPHX Units utilise a diagonal cross flow plate heat exchanger having sealed shaped plates, giving energy recovery efficiencies of up to 85%. Standard plate heat exchangers are constructed from aluminium, but ant-corrosive coatings are available for coastal or aggresive atmospheres. Please contact our sales office for further details. Face and bypass dampers, actuator operated, offer a summer by pass facility. Plate heat exchangers used in the AHPHX air handling unit range are eurovent certified,and out performs Erp 2018 Eco directive 2009/125/EC. Filters Filters are fitted to both the fresh air and return air inlets. G4 grade panel filters are used as standard. Disposable multi pocket bag filters can be offered as an alternative or secondary filter with grades F5, F6, F7 available. Manometers or pressure differential guages factory fitted are available as an option. Heating Coil Low temperature hot water heating coils are contained within the casework on slide rails for the ease of removal. Coils are constructed as standard from copper tubes and headers with aluminium fins. Optional coil construction: Bare tube (frost coils) Wide spaced fins (frost coils) Polyester coated fins. Blygold coated fins. Copper fins. HTM 03 compliant coils. Cooling Coil Options Cooling coil options are available to offer mechanical cooling, direct expansion or chilled water coils constructed from copper tubes and headers with aluminium fins as standard. Optional coil construction: Polyester coated aluminium fins. Blygold coated fins. Copper fins. Copper fins electro tinned. HTM -03 Compliant. Drain trays are fitted to cooling coils and can be fixed or removable, all drain trays have a inbuilt slope. Electric Heaters Cooling Coil Manufactured with sheathed elements, and fitted with a high temperature cut out. Balanced phase elements are arranged for thyristor or step control. 3

4 Motors operate via a 0-10V DC output from the motor, it provides infinitely variable speed control. Backward curved scroll free fans are quiet running with optimised airflow through the impeller, giving significantly reduced tonal noise. Dampers Fans Electric Heater All dampers are constructed from an aerofoil section double skin aluminium blade profile with edge, blade and side seals to offer low leakage. The blade rotation is performed by rigid nylon cogs which operate out of Air Stream. The damper operating mechanism is connected to an optional factory fitted and pre-wired actuator via a square brass drive shaft. Thermal Insulated Dampers Thermally insulated blades can be provided for fresh air and exhaust air shut off dampers which add protection to filters and coil freezing. Thermal Insulated Dampers AHPHX Compact air handling units have supply and return air backward curved centrifugal plug type fans, direct driven by high efficiency EC motors. This method of scroll free fan produces an optimal low loss flow of air through the impeller so there are no longer any drastic cross sectional changes. Multi fan wall arrangements are used to achieve higher air flow performance and efficiency. Fan Inlet Flow grids By fitting an inlet flow grid to the supply fan it is possible to achieve significant noise reduction from the fan. The noise reduction is predominantly low frequency decay (i.e. 63Hz, 125Hz, 250Hz), which can help offer significant sound power loss. This sound power loss is created by the reduction in turbulence hitting the rotating blades, with tonal frequency components, known as impellor noise or tonal noise. Tonal noise consists of the blade passing noise and its harmonics. The frequency of the blade passing noise can be calculated as the sum of the fan speed and the number of blades. A flow-grid fitted to the inlet of the fans will significantly reduce the low frequency noise generated disturbance. The vortex is split when impacting the grille as it is considerably weakened when it flows through the flowgrid. Sound pressure is reduced, particularly the low frequency. The chart below indicates the power loss in octave bands. Flowgrids Freq Hz K Fans Power loss db

5 Baseframes Casework Class Formed 2.5mm galvanised steel baseframes are fitted to all AHPHX Compact air handling units, a standard height of 100mm is included, but optional increased height baseframes are available on request. In the case of HTM - 03 and healthcare projects, the baseframe will be as laid down in the specifications. All baseframes incorporate lifting points in built into the baseframe and designed to suit the specific lifting weight of the air handling unit. Lifting instructions and method statement for securing lifting equipment are issued with OEM information on delivery. Controls AHPHX Compact air handling units can be supplied with an optional in built controls package with weatherproof options. Standard Control Package This option includes for the control panel to be built into the air handling unit casework or mounted directly onto it. All internal components will be pre-wired with isolators, actuators, sensors, thermostats, pressure switches all factory fitted. The control system will incorporate a controller which contains features to act independent or with BMS. Modbus or BACnet facility. Display features can be provided on the controller. The control package includes speed controllers built into the controller to speed regulate the E C fans. Control system options: Trend, Carel or similar controller. Output facility to operate remote condensing unit(s) or heat pump unit(s). Output to operate a thyristor controller (additional) for electric heater 0 < 10 Volt temperature regulation. Internal Control Panel External Weatherproof Control Panel AHPHX Compact air handling units have various types of casework available as detailed below. Standard Casework Standard Casework is constructed from a 30mm anodised aluminium framework with 25mm double skin insulated panels. Standard Casework Panel Options 30/25FG OPTION 1 30/25FG 0.9mm inner skin galvanised sheet metal 1.2 mm outer skin galvanised sheet metal OPTION 2 30/25FG 1.2mm inner skin galvanised sheet metal 0.7mm outer skin plastisol plastic coated steel Sound Reduction Index Frequency Hz K 2K 4K 8K Power Loss db /50FG OPTION 1 50/50FG 0.9mm inner skin galvanised sheet metal 1.2 mm outer skin galvanised sheet metal OPTION 2 50/50FG 1.2mm inner skin galvanised sheet metal 0.7mm outer skin plastisol plastic coated steel Sound Reduction Index Frequency Hz K 2K 4K 8K Power Loss db Acoustic Enhanced Casework Various acoustically enhanced panels are available with different thickness and acoustic insulation composites, frames are constructed from anodised aluminium and acoustically insulated to prevent sound leakage. All acoustic panel options are listed below with their sound reduction index. 30/25AS (Double Skin) OPTION 1 30/25AS 30mm anodised aluminium acoustic insulated frame with 25mm double skin sound barrier insulated panels. Inner Skin 0.9mm inner skin galvanised sheet metal Outer skin 1.2mm outer skin galvanised sheet metal OPTION 2 30/25AS 1.2mm inner skin galvanised sheet metal 0.7mm outer skin plastisol plastic coated steel Sound Reduction Index 50/50 PB (Double Skin) Frequency Hz K 2K 4K 8K Power Loss db

6 30/25PB (Double Skin) OPTION 1 30/25PB 30mm anodised aluminium acoustic insulated frame with 25mm double skin sound barrier insulated panels. Inner Skin 0.9mm inner skin galvanised sheet metal Outer skin 1.2mm outer skin galvanised sheet metal OPTION 2 30/25PB 1.2mm inner skin galvanised sheet metal 0.7mm outer skin plastisol plastic coated steel Sound Reduction Index Frequency Hz K 2K 4K 8K Power Loss db /25TS PB (Triple Skin) OPTION 1 30/25TS PB 30mm anodised aluminium acoustic insulated frame with 25mm double skin sound barrier insulated panels. Inner Skin 0.9mm inner skin galvanised sheet metal Intermediate skin 0.9mm inner skin galvanised sheet metal Outer skin 1.2mm outer skin galvanised sheet metal OPTION 2 30/25TS PB 1.2mm inner skin galvanised sheet metal 1.2mm intermediate skin galvanised sheet metal 0.7mm outer skin plastisol plastic coated steel Sound Reduction Index Frequency Hz K 2K 4K 8K Power Loss db /50FG PB (Double Skin) OPTION 1 50/50FG PB 50mm anodised aluminium acoustic insulated frame with 50mm double skin acoustic composite insulated panels. Inner Skin 0.9mm inner skin galvanised sheet metal Outer skin 1.2mm outer skin galvanised sheet metal OPTION 2 50/50FG PB 1.2mm inner skin galvanised sheet metal 0.7mm outer skin plastisol plastic coated steel Sound Reduction Index Frequency Hz K 2K 4K 8K Power Loss db /50FG TS PB (Triple Skin) OPTION 1 30/25FG TS PB 50mm anodised aluminium acoustic insulated frame with 50mm triple skin acoustic composite panels. Inner Skin 0.9mm inner skin galvanised sheet metal Intermediate skin 0.9mm inner skin galvanised sheet metal Outer skin 1.2mm outer skin galvanised sheet metal OPTION 2 50/50FG TS PB 1.2mm inner skin galvanised sheet metal 1.2mm intermediate skin galvanised sheet metal 0.7mm outer skin plastisol plastic coated steel Sound Reduction Index Frequency Hz K 2K 4K 8K Power Loss db /50AS TS PB (Triple Skin) OPTION 1 50/50AS TS PB 50mm anodised aluminium acoustic insulated frame with 50mm triple skin acoustic composite panels. Inner Skin 0.9mm inner skin galvanised sheet metal Intermediate skins 0.9mm inner skin galvanised sheet metal Outer skin 1.2mm outer skin galvanised sheet metal OPTION 2 50/50AS TS PB 1.2mm inner skin galvanised sheet metal 1.2mm intermediate skin galvanised sheet metal 0.7mm outer skin plastisol plastic coated steel Sound Reduction Index Frequency Hz K 2K 4K 8K Power Loss db /50AS QS PB (Quadrouple Skin) OPTION 1 50/50AS QS PB 50mm anodised aluminium acoustic insulated frame with 50mm quadruple skin acoustic composite insulated panels. Inner Skin 0.9mm inner skin galvanised sheet metal Intermediate skin 2 off 0.9mm intermediate skins galvanised sheet metal Outer skin 1.2mm outer skin galvanised sheet metal OPTION 2 50/50AS QS PB 1.2mm inner skin galvanised sheet metal 2 off 1.2mm intermediate skins galvanised sheet metal 0.7mm outer skin plastisol plastic coated steel Sound Reduction Index Frequency Hz K 2K 4K 8K Power Loss db

7 Certification All acoustic SRI tests are certified by Salford University Test Laboratories to BS EN ISO (2010) Report No s 1429 & Accreditation In partnership with Salford University acoustic testing laboratory a range of composite acoustic panels have been designed and tested. To obtain the true casework noise breakout, the frame and panel assembly have to be tested with a large enough area sample to give a true representation of AHPHX Compact casework. In practice the framework can leak sound which will flank the panels. Therefore the frame must be acoustically insulated to the same standard as the panels. Test set up during testing programme Assembling test frame and panels 7

8 Type AHPHX Compact air handling units are double stacked in configuration, and can contain different components which are described in their individual type and make up of components. The performance charts will relate to the type of AHPHX Compact unit components make up, which allows for individual components maximum pressure drops. Type 1 Components available for selection with type 1 AHPHX Compact Units: Inlet attenuators. Inlet/ exhaust dampers. Mixing box/recirculation section Plate exchanger heat recovery device with face and bypass dampers and drain tray. Panel filters G3/G4 grade on supply and extract. Fan selection containing E.C. backward curved plug fan(s). Discharge attenuators. Type 2 Components available for selection with type 2 AHPHX Compact Units: Inlet attenuators. Inlet/exhaust dampers. Mixing box/recirculation section Plate exchanger heat recovery device with face and bypass dampers and drain tray. Panel filters G3/G4 grade on supply and extract. Electric heater battery. LPHW heating coil. Fan section containing E.C. backward curved plug fan(s). Discharge attenuators. Type 3 Components available for selection with type 3 AHPHX Compact Units: Inlet attenuators. Inlet dampers. Mixing box/recirculation section. Plate exchanger heat recovery device with face and bypass dampers and drain tray. Panel filters G3/G4 grades on supply and extract. Bag filters grade F5/F6/F7 Electric heater battery. LPHW coil. Fan selection containing E.C. backward curved plug fan(s). Cooling coil chilled water or direct expansion heat pump arrangement coil available. Discharge attenuators. Type 4 Components available for selection with type 4 AHPHX Compact Units Inlet attenuators. Inlet dampers. Mixing box/ recirculation section. Rotary thermal wheel heat recovery device. Panel filters G3/G4 grades on supply and extract. Electric heater battery. LPHW coil. Fan section containing E.C. backward curved plug fan(s). Cooling coil chilled water or direct expansion heat pump coil available. Bag filters F5/F6/F7 grade. Discharge attenuators. Note The casework class does not affect the performance value in the selection charts but will affect the dimensions of the unit and its acoustic breakout performance. 8

9 Selection Chart MODEL AHPHX 800/T1/ /1F Performance TYPICAL TYPE 1 COMPONENT CONFIGURATION External Pressure Pascals Airflow (m³/hr) Inlet SWL (db) Outlet SWL (db) Absorbed power (Watts) Airflow (m³/hr) Dry Efficiency % Wet Efficiency % Supply Air Lat C Energy Recovered (Kw) EQUAL FLOWS ECO DIRECTIVE ErP 2016/2018 COMPLIANT 390WATTS 2350RPM EC310/390/1F Plate Heat Exchanger with by pass Model PHX/W /D Casework Class Weight (kg) H1 H2 H3 H4 H5 H6 H7 W1 W2 L1 30/25 FG /25 AS /25 PB /25 TS PB /50 FG /50 FG PB /50 FG TS PB /50 AS TS PB /50 AS QS PB

10 Selection Chart MODEL AHPHX 800/T2/ /1F Performance TYPICAL TYPE 2 COMPONENT CONFIGURATION External Pressure Pascals Airflow (m³/hr) Inlet SWL (db) Outlet SWL (db) Absorbed power (Watts) Airflow (m³/hr) Dry Efficiency % Wet Efficiency % Supply Air Lat C Energy Recovered (Kw) EQUAL FLOWS ECO DIRECTIVE ErP 2016/2018 COMPLIANT 390WATTS 2350RPM EC310/390/1F Plate Heat Exchanger with by pass Model PHX/W /D Electric Heater Data Based on minimum airflow 9Kw single or three phase electric supply. LPHW Coil Data Based on maximum airflow and 82/71 C. Maximum heating output 10Kw. Casework Class Weight (kg) H1 H2 H3 H4 H5 H6 H7 W1 W2 L1 L2 30/25 FG /25 AS /25 PB /25 TS PB /50 FG /50 FG PB /50 FG TS PB /50 AS TS PB /50 AS QS PB NOTE Type 2 (T2) AHPHX Units have a single bottom deck section attached to the type 1 (T1), containing an electric or LPHW Heating Coil as illustrated on the above diagram. 10

11 Selection Chart MODEL AHPHX 800/T3/ /1F Performance TYPICAL TYPE 3 COMPONENT CONFIGURATION 390WATTS 2350RPM EC /1F Plate Heat Exchanger with by pass Model PHX/W /D External Pressure Pascals Airflow (m³/hr) Inlet SWL (db) Outlet SWL (db) Absorbed power (Watts) Airflow (m³/hr) Electric Heater Data Based on maximum airflow 9Kw single or three phase electric supply. LPHW Coil Data Based on maximum airflow and 82/71 C. Maximum heating output 10Kw. Cooling/Heat Pump Coil Data Chilled water/direct expansion coil data based on maximum airflow & chilled 6/12 C or DX 6 C. Max cooling output 9Kw. Dry Efficiency % Wet Efficiency % Supply Air Lat C Energy Recovered (Kw) EQUAL FLOWS ECO DIRECTIVE ErP 2016/2018 COMPLIANT Casework Class Weight (kg) H1 H2 H3 H4 H5 H6 H7 W1 W2 L1 L2 30/25 FG /25 AS /25 PB /25 TS PB /50 FG /50 FG PB /50 FG TS PB /50 AS TS PB /50 AS QS PB NOTE Type 3 (T3) AHPHX Units have a single bottom deck section attached to the type 1 (T1) unit, containing an electric or LPHW heating coil, together with a chilled water or direct expansion cooling coil. A heat pump coil is also available in this section as an option. All as illustrated on the above diagram. 11

12 Selection Chart MODEL AHPHX 800/T4/ /1F Performance TYPICAL TYPE 4 COMPONENT CONFIGURATION 390WATTS 2350RPM EC310/390/1F External Pressure Pascals Airflow (m³/hr) Inlet SWL (db) Outlet SWL (db) Absorbed power (Watts) Airflow (m³/hr) Dry Efficiency % Wet Efficiency % Supply Air Lat C Energy Recovered (Kw) Secondary F7 grade Bag Filters Plate Heat Exchanger with by pass Model PHX/W /D EQUAL FLOWS ECO DIRECTIVE ErP 2016/2018 COMPLIANT Electric Heater Data Based on minimum airflow 9Kw single or three phase electric supply. LPHW Coil Data Based on maximum airflow and 82/71 C. Maximum heating output 10Kw. Cooling/Heat Pump Coil Data Chilled water/direct expansion coil data based on maximum airflow & chilled 6/12 C or DX 6 C. Max cooling output 9Kw. Casework Class Weight (kg) H1 H2 H3 H4 H5 H6 H7 W1 W2 L1 L2 30/25 FG /25 AS /25 PB /25 TS PB /50 FG /50 FG PB /50 FG TS PB /50 AS TS PB /50 AS QS PB NOTE Type 3 (T3) AHPHX Units have a single bottom deck section attached to the type 1 (T1) unit, containing an electric or LPHW heating coil, together with a chilled water or direct expansion cooling coil. A heat pump coil is also available in this section as an option. All as illustrated on the above diagram. Section includes a F5 to F7 grade Bag Filter arranged for side withdrawal. 12

13 Selection Chart MODEL AHPHX 1000/T1/ /1F Performance TYPICAL TYPE 1 COMPONENT CONFIGURATION External Pressure Pascals Airflow (m³/hr) Inlet SWL (db) Outlet SWL (db) Absorbed power (Watts) Airflow (m³/hr) Dry Efficiency % Wet Efficiency % Supply Air Lat C Energy Recovered (Kw) EQUAL FLOWS ECO DIRECTIVE ErP 2016/2018 COMPLIANT 680WATTS 3000RPM EC310/680/1F Plate Heat Exchanger with by pass Model PHX/W1000/D Casework Class Weight (kg) H1 H2 H3 H4 H5 H6 H7 W1 W2 L1 30/25 FG /25 AS /25 PB /25 TS PB /50 FG /50 FG PB /50 FG TS PB /50 AS TS PB /50 AS QS PB

14 Selection Chart MODEL AHPHX 1000/T2/ /1F Performance TYPICAL TYPE 2 COMPONENT CONFIGURATION 680WATTS 3000RPM EC310/680/1F Plate Heat Exchanger with by pass Model PHX/W1000/ Electric Heater Data Based on maximum airflow 18Kw single or three phase electric supply. LPHW Coil Data Based on maximum airflow and 82/71 C. Maximum heating output 20Kw. External Pressure Pascals Airflow (m³/hr) Inlet SWL (db) Outlet SWL (db) Absorbed power (Watts) Airflow (m³/hr) Dry Efficiency % Wet Efficiency % Supply Air Lat C Energy Recovered (Kw) EQUAL FLOWS ECO DIRECTIVE ErP 2016/2018 COMPLIANT Casework Class Weight (kg) H1 H2 H3 H4 H5 H6 H7 W1 W2 L1 L2 30/25 FG /25 AS /25 PB /25 TS PB /50 FG /50 FG PB /50 FG TS PB /50 AS TS PB /50 AS QS PB NOTE Type 2 (T2) AHPHX Units have a single bottom deck section attached to the type 1 (T1), containing an electric or LPHW Heating Coil as illustrated on the above diagram. 14

15 Selection Chart MODEL AHPHX 1000/T3/ /1F Performance TYPICAL TYPE 3 COMPONENT CONFIGURATION 680WATTS 3000RPM EC310/680/1F Plate Heat Exchanger with by pass Model PHX/W /D1175 External Pressure Pascals Airflow (m³/hr) Inlet SWL (db) Outlet SWL (db) Absorbed power (Watts) Cooling/Heat Pump Coil Data Chilled water/direct expansion coil data based on maximum airflow & chilled 6/12 C or DX 6 C. Max cooling output 20Kw. Airflow (m³/hr) Dry Efficiency % Wet Efficiency % Supply Air Lat C Energy Recovered (Kw) EQUAL FLOWS ECO DIRECTIVE ErP 2016/2018 COMPLIANT Electric Heater Data Based on minimum airflow 15Kw single or three phase electric supply. LPHW Coil Data Based on maximum airflow and 82/71 C. Maximum heating output 16Kw. Casework Class Weight (kg) H1 H2 H3 H4 H5 H6 H7 W1 W2 L1 L2 30/25 FG /25 AS /25 PB /25 TS PB /50 FG /50 FG PB /50 FG TS PB /50 AS TS PB /50 AS QS PB NOTE Type 3 (T3) AHPHX Units have a single bottom deck section attached to the type 1 (T1) unit, containing an electric or LPHW heating coil, together with a chilled water or direct expansion cooling coil. A heat pump coil is also available in this section as an option. All as illustrated on the above diagram. 15

16 Selection Chart MODEL AHPHX 1000/T4/ /1F Performance TYPICAL TYPE 4 COMPONENT CONFIGURATION WATTS 3000RPM EC310/680/1F Secondary F7 Bag Filters. Plate Heat Exchanger with by pass Model PHX/W /D1175 External Pressure Pascals Airflow (m³/hr) Inlet SWL (db) Outlet SWL (db) Absorbed power (Watts) Airflow (m³/hr) Dry Efficiency % Wet Efficiency % Supply Air Lat C Energy Recovered (Kw) EQUAL FLOWS ECO DIRECTIVE ErP 2016/2018 COMPLIANT Electric Heater Data Based on maximum airflow 15Kw single or three phase electric supply. LPHW Coil Data Based on maximum airflow and 82/71 C. Maximum heating output 16Kw. Casework Class Weight (kg) H1 H2 H3 H4 H5 H6 H7 W1 W2 L1 Cooling/Heat Pump Coil Data Chilled water/direct expansion coil data based on maximum airflow & chilled 6/12 C or DX 6 C. Max cooling output 20Kw. 30/25 FG /25 AS /25 PB /25 TS PB /50 FG /50 FG PB /50 FG TS PB /50 AS TS PB /50 AS QS PB NOTE Type 3 (T3) AHPHX Units have a single bottom deck section attached to the type 1 (T1) unit, containing an electric or LPHW heating coil, together with a chilled water or direct expansion cooling coil. A heat pump coil is also available in this section as an option. All as illustrated on the above diagram. Section includes a F5 to F7 grade Bag Filter arranged for side withdrawal.

17 Selection Chart MODEL AHPHX 1500/T1/ /2F Performance TYPICAL TYPE 1 COMPONENT CONFIGURATION External Pressure Pascals Airflow (m³/hr) Inlet SWL (db) Outlet SWL (db) Absorbed power (Watts) Airflow (m³/hr) Dry Efficiency % Wet Efficiency % Supply Air Lat C Energy Recovered (Kw) EQUAL FLOWS ECO DIRECTIVE ErP 2016/2018 COMPLIANT 780WATTS 2350RPM EC310/390/2F Plate Heat Exchanger with by pass Model PHX/W /D Casework Class Weight (kg) H1 H2 H3 H4 H5 H6 H7 W1 W2 L1 30/25 FG /25 AS /25 PB /25 TS PB /50 FG /50 FG PB /50 FG TS PB /50 AS TS PB /50 AS QS PB

18 Selection Chart MODEL AHPHX 1500/T2/ /2F Performance TYPICAL TYPE 2 COMPONENT CONFIGURATION External Pressure Pascals Airflow (m³/hr) Inlet SWL (db) Outlet SWL (db) Absorbed power (Watts) Airflow (m³/hr) Dry Efficiency % Wet Efficiency % Supply Air Lat C Energy Recovered (Kw) EQUAL FLOWS ECO DIRECTIVE ErP 2016/2018 COMPLIANT 780WATTS 2350RPM EC310/390/2F Plate Heat Exchanger with by pass Model PHX/W /D Electric Heater Data Based on minimum airflow 24Kw single or three phase electric supply. LPHW Coil Data Based on maximum airflow and 82/71 C. Maximum heating output 26Kw. Casework Class Weight (kg) H1 H2 H3 H4 H5 H6 H7 W1 W2 L1 L2 30/25 FG /25 AS /25 PB /25 TS PB /50 FG /50 FG PB /50 FG TS PB /50 AS TS PB /50 AS QS PB NOTE Type 2 (T2) AHPHX Units have a single bottom deck section attached to the type 1 (T1), containing an electric or LPHW Heating Coil as illustrated on the above diagram. 18

19 Selection Chart MODEL AHPHX 1500/T3/ /2F Performance TYPICAL TYPE 3 COMPONENT CONFIGURATION 780WATTS 2350RPM EC310/390/2F Plate Heat Exchanger with by pass Model PHX/W /D External Pressure Pascals Airflow (m³/hr) Inlet SWL (db) Outlet SWL (db) Absorbed power (Watts) Airflow (m³/hr) Dry Efficiency % Wet Efficiency % Supply Air Lat C Energy Recovered (Kw) Electric Heater Data Based on minimum airflow 24Kw single or three phase electric supply. LPHW Coil Data Based on maximum airflow and 82/71 C. Maximum heating output 26Kw. Cooling/Heat Pump Coil Data Chilled water/direct expansion coil data based on maximum airflow & chilled 6/12 C or DX 6 C. Max cooling output 21Kw. EQUAL FLOWS ECO DIRECTIVE ErP 2016/2018 COMPLIANT Casework Class Weight (kg) H1 H2 H3 H4 H5 H6 H7 W1 W2 L1 L2 30/25 FG /25 AS /25 PB /25 TS PB /50 FG /50 FG PB /50 FG TS PB /50 AS TS PB /50 AS QS PB NOTE Type 3 (T3) AHPHX Units have a single bottom deck section attached to the type 1 (T1) unit, containing an electric or LPHW heating coil, together with a chilled water or direct expansion cooling coil. A heat pump coil is also available in this section as an option. All as illustrated on the above diagram. 19

20 Selection Chart MODEL AHPHX 1500/T4/ /2F Performance TYPICAL TYPE 4 COMPONENT CONFIGURATION WATTS 2350RPM EC310/390/2F External Pressure Pascals Airflow (m³/hr) Inlet SWL (db) Outlet SWL (db) Absorbed power (Watts) Airflow (m³/hr) Secondary F7 grade Bag Filters Plate Heat Exchanger with by pass Mode PHX/W /D790 Dry Efficiency % Wet Efficiency % Supply Air Lat C Energy Recovered (Kw) EQUAL FLOWS ECO DIRECTIVE ErP 2016/2018 COMPLIANT Electric Heater Data Based on minimum airflow 24Kw single or three phase electric supply. LPHW Coil Data Based on maximum airflow and 82/71 C. Maximum heating output 26Kw. Cooling/Heat Pump Coil Data Chilled water/direct expansion coil data based on maximum airflow & chilled 6/12 C or DX 6 C. Max cooling output 21Kw. Casework Class Weight (kg) H1 H2 H3 H4 H5 H6 H7 W1 W2 L1 L2 30/25 FG /25 AS /25 PB /25 TS PB /50 FG /50 FG PB /50 FG TS PB /50 AS TS PB /50 AS QS PB NOTE Type 3 (T3) AHPHX Units have a single bottom deck section attached to the type 1 (T1) unit, containing an electric or LPHW heating coil, together with a chilled water or direct expansion cooling coil. A heat pump coil is also available in this section as an option. All as illustrated on the above diagram. Section includes a F5 to F7 grade Bag Filter arranged for side withdrawal.

21 Selection Chart MODEL AHPHX 1700/T1/ /2F Performance TYPICAL TYPE 1 COMPONENT CONFIGURATION External Pressure Pascals Airflow (m³/hr) Inlet SWL (db) Outlet SWL (db) Absorbed power (Watts) Airflow (m³/hr) Dry Efficiency % Wet Efficiency % Supply Air Lat C Energy Recovered (Kw) EQUAL FLOWS ECO DIRECTIVE ErP 2016/2018 COMPLIANT 1360WATTS 3000RPM EC310/680/2F Plate Heat Exchanger with by pass Model PHX/W /D1390 Casework Class Weight (kg) H1 H2 H3 H4 H5 H6 H7 W1 W2 L1 30/25 FG /25 AS /25 PB /25 TS PB /50 FG /50 FG PB /50 FG TS PB /50 AS TS PB /50 AS QS PB

22 Selection Chart MODEL AHPHX/1700/T2/ /2F Performance TYPICAL TYPE 2 COMPONENT CONFIGURATION 1360WATTS 3000RPM EC310/680/2F Plate Heat Exchanger with by pass Model PHX/W /D1390 Electric Heater Data Based on minimum airflow 33Kw single or three phase electric supply. LPHW Coil Data Based on maximum airflow and 82/71 C. Maximum heating output 36Kw. External Pressure Pascals Airflow (m³/hr) Inlet SWL (db) Outlet SWL (db) Absorbed power (Watts) Airflow (m³/hr) Dry Efficiency % Wet Efficiency % Supply Air Lat C Energy Recovered (Kw) EQUAL FLOWS ECO DIRECTIVE ErP 2016/2018 COMPLIANT Casework Class Weight (kg) H1 H2 H3 H4 H5 H6 H7 W1 W2 L1 L2 30/25 FG /25 AS /25 PB /25 TS PB /50 FG /50 FG PB /50 FG TS PB /50 AS TS PB /50 AS QS PB NOTE Type 2 (T2) AHPHX Units have a single bottom deck section attached to the type 1 (T1), containing an electric or LPHW Heating Coil as illustrated on the above diagram. 22

23 Selection Chart MODEL AHPHX 1700/T3/ F Performance TYPICAL TYPE 3 COMPONENT CONFIGURATION 680WATTS 3000RPM EC310/680/2F Plate Heat Exchanger with by pass Model PHX/W /D1390 External Pressure Pascals Airflow (m³/hr) Inlet SWL (db) Outlet SWL (db) Absorbed power (Watts) Cooling/Heat Pump Coil Data Chilled water/direct expansion coil data based on maximum airflow & chilled 6/12 C or DX 6 C. Max cooling output 36Kw. Airflow (m³/hr) Dry Efficiency % Wet Efficiency % Supply Air Lat C Energy Recovered (Kw) EQUAL FLOWS ECO DIRECTIVE ErP 2016/2018 COMPLIANT Electric Heater Data Based on minimum airflow 33Kw single or three phase electric supply. LPHW Coil Data Based on maximum airflow and 82/71 C. Maximum heating output 36Kw. Casework Class Weight (kg) H1 H2 H3 H4 H5 H6 H7 W1 W2 L1 L2 30/25 FG /25 AS /25 PB /25 TS PB /50 FG /50 FG PB /50 FG TS PB /50 AS TS PB /50 AS QS PB NOTE Type 3 (T3) AHPHX Units have a single bottom deck section attached to the type 1 (T1) unit, containing an electric or LPHW heating coil, together with a chilled water or direct expansion cooling coil. A heat pump coil is also available in this section as an option. All as illustrated on the above diagram. 23

24 Selection Chart MODEL AHPHX 1700/T4/ /2F Performance TYPICAL TYPE 4 COMPONENT CONFIGURATION WATTS 3000RPM EC310/680/2F Secondary F7 Bag Filters. Plate Heat Exchanger with by pass Model PHX/W /D1390 External Pressure Pascals Airflow (m³/hr) Inlet SWL (db) Outlet SWL (db) Absorbed power (Watts) Airflow (m³/hr) Dry Efficiency % Wet Efficiency % Supply Air Lat C Energy Recovered (Kw) EQUAL FLOWS ECO DIRECTIVE ErP 2016/2018 COMPLIANT Electric Heater Data Based on minimum airflow 33Kw single or three phase electric supply. LPHW Coil Data Based on maximum airflow and 82/71 C. Maximum heating output 33Kw. Cooling/Heat Pump Coil Data Chilled water/direct expansion coil data based on maximum airflow & chilled 6/12 C or DX 6 C. Max cooling output 36Kw. Casework Class Weight (kg) H1 H2 H3 H4 H5 H6 H7 W1 W2 L1 L2 30/25 FG /25 AS /25 PB /25 TS PB /50 FG /50 FG PB /50 FG TS PB /50 AS TS PB /50 AS QS PB NOTE Type 3 (T3) AHPHX Units have a single bottom deck section attached to the type 1 (T1) unit, containing an electric or LPHW heating coil, together with a chilled water or direct expansion cooling coil. A heat pump coil is also available in this section as an option. All as illustrated on the above diagram. Section includes a F5 to F7 grade Bag Filter arranged for side withdrawal.

25 Selection Chart MODEL AHPHX 1800/T1/ /3F Performance TYPICAL TYPE 1 COMPONENT CONFIGURATION External Pressure Pascals Airflow (m³/hr) Inlet SWL (db) Outlet SWL (db) Absorbed power (Watts) Airflow (m³/hr) Dry Efficiency % Wet Efficiency % Supply Air Lat C Energy Recovered (Kw) EQUAL FLOWS ECO DIRECTIVE ErP 2016/2018 COMPLIANT 1170WATTS 2350RPM EC310/390/3F Plate Heat Exchanger with by pass Model PHX/W /D Casework Class Weight (kg) H1 H2 H3 H4 H5 H6 H7 W1 W2 L1 30/25 FG /25 AS /25 PB /25 TS PB /50 FG /50 FG PB /50 FG TS PB /50 AS TS PB /50 AS QS PB

26 Selection Chart MODEL AHPHX 1800/T2/ /3F Performance TYPICAL TYPE 2 COMPONENT CONFIGURATION External Pressure Pascals Airflow (m³/hr) Inlet SWL (db) Outlet SWL (db) Absorbed power (Watts) Airflow (m³/hr) Dry Efficiency % Wet Efficiency % Supply Air Lat C Energy Recovered (Kw) EQUAL FLOWS ECO DIRECTIVE ErP 2016/2018 COMPLIANT Rotary Thermal Wheel efficiency based on return air entering at 21 C db/50% relative humidity. Supply air entering at -5 C db/95% relative humidity. 1170WATTS 2350RPM EC310/390/3F Plate Heat Exchanger with by pass Model PHX/W /D Electric Heater Data Based on minimum airflow 33Kw single or three phase electric supply. LPHW Coil Data Based on maximum airflow and 82/71 C. Maximum heating output 36Kw. Casework Class Weight (kg) H1 H2 H3 H4 H5 H6 H7 W1 W2 L1 L2 30/25 FG /25 AS /25 PB /25 TS PB /50 FG /50 FG PB /50 FG TS PB /50 AS TS PB /50 AS QS PB NOTE Type 2 (T2) AHPHX Units have a single bottom deck section attached to the type 1 Unit (T1), containing an electric or LPHW heating coil as illustrated on the above diagram. 26

27 Selection Chart MODEL AHPHX 1800/T3/ /3F Performance TYPICAL TYPE 3 COMPONENT CONFIGURATION 1170 WATTS 2350RPM EC310/390/3F Plate Heat Exchanger with by pass Model PHX/W /D External Pressure Pascals Airflow (m³/hr) Inlet SWL (db) Outlet SWL (db) Absorbed power (Watts) Airflow (m³/hr) Dry Efficiency % Wet Efficiency % Supply Air Lat C Energy Recovered (Kw) Electric Heater Data Based on minimum airflow 33Kw single or three phase electric supply. LPHW Coil Data Based on maximum airflow and 82/71 C. Maximum heating output 36 Kw. Cooling/Heat Pump Coil Data Chilled water/direct expansion coil data based on maximum airflow & chilled 6/12 C or DX 6 C. Max cooling output 36Kw. EQUAL FLOWS ECO DIRECTIVE ErP 2016/2018 COMPLIANT Casework Class Weight (kg) H1 H2 H3 H4 H5 H6 H7 W1 W2 L1 L2 30/25 FG /25 AS /25 PB /25 TS PB /50 FG /50 FG PB /50 FG TS PB /50 AS TS PB /50 AS QS PB NOTE Type 3 (T3) AHPHX Units have a single bottom deck section attached to the type 1 (T1) unit, containing an electric or LPHW heating coil, together with a chilled water or direct expansion cooling coil. A heat pump coil is also available in this section as an option. All as illustrated on the above diagram. 27

28 Selection Chart MODEL AHPHX 1800/T4/ /3F Performance TYPICAL TYPE 4 COMPONENT CONFIGURATION WATTS 2350RPM EC310/390/3F External Pressure Pascals Airflow (m³/hr) Inlet SWL (db) Outlet SWL (db) Absorbed power (Watts) Airflow (m³/hr) Dry Efficiency % Wet Efficiency % Supply Air Lat C Energy Recovered (Kw) Secondary F7 grade Bag Filters Plate Heat Exchanger with by pass Model PHX/W /D Electric Heater Data Based on minimum airflow 21Kw single or three phase electric supply. LPHW Coil Data Based on maximum airflow and 82/71 C. Maximum heating output 25Kw. Cooling/Heat Pump Coil Data Chilled water/direct expansion coil data based on maximum airflow & chilled 6/12 C or DX 6 C. Max cooling output 24Kw. EQUAL FLOWS ECO DIRECTIVE ErP 2016/2018 COMPLIANT Casework Class Weight (kg) H1 H2 H3 H4 H5 H6 H7 W1 W2 L1 L2 30/25 FG /25 AS /25 PB /25 TS PB /50 FG /50 FG PB /50 FG TS PB /50 AS TS PB /50 AS QS PB NOTE Type 3 (T3) AHPHX Units have a single bottom deck section attached to the type 1 (T1) unit, containing an electric or LPHW heating coil, together with a chilled water or direct expansion cooling coil. A heat pump coil is also available in this section as an option. All as illustrated on the above diagram. Section includes a F5 to F7 grade Bag Filter arranged for side withdrawal.

29 Selection Chart MODEL AHPHX 2000/T1/ /3F Performance TYPICAL TYPE 1 COMPONENT CONFIGURATION External Pressure Pascals Airflow (m³/hr) Inlet SWL (db) Outlet SWL (db) Absorbed power (Watts) Airflow (m³/hr) Dry Efficiency % Wet Efficiency % Supply Air Lat C Energy Recovered (Kw) EQUAL FLOWS ECO DIRECTIVE ErP 2016/2018 COMPLIANT 2040WATTS 3000RPM EC310/680/3F Plate Heat Exchanger with by pass Model PHX/W /D Casework Class Weight (kg) H1 H2 H3 H4 H5 H6 H7 W1 W2 L1 30/25 FG /25 AS /25 PB /25 TS PB /50 FG /50 FG PB /50 FG TS PB /50 AS TS PB /50 AS QS PB

30 Selection Chart MODEL AHPHX 2000/T2/ /3F Performance TYPICAL TYPE 2 COMPONENT CONFIGURATION 2040WATTS 3000RPM EC310/680/3F Plate Heat Exchanger with by pass Model PHX/W /D Electric Heater Data Based on minimum airflow 54Kw single or three phase electric supply. LPHW Coil Data Based on maximum airflow and 82/71 C. Maximum heating output 60Kw. External Pressure Pascals Airflow (m³/hr) Inlet SWL (db) Outlet SWL (db) Absorbed power (Watts) Airflow (m³/hr) Dry Efficiency % Wet Efficiency % Supply Air Lat C Energy Recovered (Kw) EQUAL FLOWS ECO DIRECTIVE ErP 2016/2018 COMPLIANT Casework Class Weight (kg) H1 H2 H3 H4 H5 H6 H7 W1 W2 L1 L2 30/25 FG /25 AS /25 PB /25 TS PB /50 FG /50 FG PB /50 FG TS PB /50 AS TS PB /50 AS QS PB NOTE Type 2 (T2) AHPHX Units have a single bottom deck section attached to the type 1 (T1), containing an electric or LPHW Heating Coil as illustrated on the above diagram. 30

31 Selection Chart MODEL AHPHX 2000/T3/ /3F Performance TYPICAL TYPE 3 COMPONENT CONFIGURATION 2040WATTS 3000RPM EC310/680/3F Plate Heat Exchanger with by pass Model PHX/W /D External Pressure Pascals Airflow (m³/hr) Inlet SWL (db) Outlet SWL (db) Absorbed power (Watts) Airflow (m³/hr) Dry Efficiency % Wet Efficiency % Supply Air Lat C Energy Recovered (Kw) EQUAL FLOWS ECO DIRECTIVE ErP 2016/2018 COMPLIANT Electric Heater Data Based on maximum airflow 51Kw single or three phase electric supply. LPHW Coil Data Based on maximum airflow and 82/71 C. Maximum heating output 55Kw. Cooling/Heat Pump Coil Data Chilled water/direct expansion coil data based on maximum airflow & chilled 6/12 C or DX 6 C. Max cooling output 55Kw. Casework Class Weight (kg) H1 H2 H3 H4 H5 H6 H7 W1 W2 L1 L2 30/25 FG /25 AS /25 PB /25 TS PB /50 FG /50 FG PB /50 FG TS PB /50 AS TS PB /50 AS QS PB NOTE Type 3 (T3) AHPHX Units have a single bottom deck section attached to the type 1 (T1) unit, containing an electric or LPHW heating coil, together with a chilled water or direct expansion cooling coil. A heat pump coil is also available in this section as an option. All as illustrated on the above diagram. 31

32 Selection Chart MODEL AHPHX 2000/T4/ /3F Performance TYPICAL TYPE 4 COMPONENT CONFIGURATION WATTS 3000RPM EC310/680/3F Secondary F7 Bag Filters. Plate Heat Exchanger with by pass Model PHX/W /D External Pressure Pascals Airflow (m³/hr) Inlet SWL (db) Outlet SWL (db) Absorbed power (Watts) Airflow (m³/hr) Dry Efficiency % Wet Efficiency % Supply Air Lat C Energy Recovered (Kw) EQUAL FLOWS ECO DIRECTIVE ErP 2016/2018 COMPLIANT Electric Heater Data Based on minimum airflow 42Kw single or three phase electric supply. LPHW Coil Data Based on maximum airflow and 82/71 C. Maximum heating output 46Kw. Cooling/Heat Pump Coil Data Chilled water/direct expansion coil data based on maximum airflow & chilled 6/12 C or DX 6 C. Max cooling output 45Kw. Casework Class Weight (kg) H1 H2 H3 H4 H5 H6 H7 W1 W2 L1 L2 30/25 FG /25 AS /25 PB /25 TS PB /50 FG /50 FG PB /50 FG TS PB /50 AS TS PB /50 AS QS PB NOTE Type 3 (T3) AHPHX Units have a single bottom deck section attached to the type 1 (T1) unit, containing an electric or LPHW heating coil, together with a chilled water or direct expansion cooling coil. A heat pump coil is also available in this section as an option. All as illustrated on the above diagram. Section includes a F5 to F7 grade Bag Filter arranged for side withdrawal.

33 Selection Chart MODEL AHPHX 2100/T1/ /4F Performance TYPICAL TYPE 1 COMPONENT CONFIGURATION External Pressure Pascals Airflow (m³/hr) Inlet SWL (db) Outlet SWL (db) Absorbed power (Watts) Airflow (m³/hr) Dry Efficiency % Wet Efficiency % Supply Air Lat C Energy Recovered (Kw) EQUAL FLOWS ECO DIRECTIVE ErP 2016/2018 COMPLIANT 1560WATTS 2350RPM EC310/390/4F Plate Heat Exchanger with by pass Model PHX/W /D Casework Class Weight (kg) H1 H2 H3 H4 H5 H6 H7 W1 W2 L1 30/25 FG /25 AS /25 PB /25 TS PB /50 FG /50 FG PB /50 FG TS PB /50 AS TS PB /50 AS QS PB

34 Selection Chart AHPHX 2100/T2/ /4F Performance TYPICAL TYPE 2 COMPONENT CONFIGURATION External Pressure Pascals Airflow (m³/hr) Inlet SWL (db) Outlet SWL (db) Absorbed power (Watts) Airflow (m³/hr) Dry Efficiency % Wet Efficiency % Supply Air Lat C Energy Recovered (Kw) EQUAL FLOWS ECO DIRECTIVE ErP 2016/2018 COMPLIANT 1560WATTS 2350RPM EC310/390/4F Plate Heat Exchanger with by pass Model PHX/W /D Electric Heater Data Based on maximum airflow 45Kw single or three phase electric supply. LPHW Coil Data Based on maximum airflow and 82/71 C. Maximum heating output 50Kw. Casework Class Weight (kg) H1 H2 H3 H4 H5 H6 H7 W1 W2 L1 L2 30/25 FG /25 AS /25 PB /25 TS PB /50 FG /50 FG PB /50 FG TS PB /50 AS TS PB /50 AS QS PB NOTE Type 2 (T2) AHPHX Units have a single bottom deck section attached to the type 1 (T1), containing an electric or LPHW Heating Coil as illustrated on the above diagram. 34

35 Selection Chart MODEL AHPHX 2100/T3/ /4F Performance TYPICAL TYPE 3 COMPONENT CONFIGURATION 1560WATTS 2350RPM EC310/390/4F Plate Heat Exchanger with by pass Model PHX/W /D External Pressure Pascals Airflow (m³/hr) Inlet SWL (db) Outlet SWL (db) Absorbed power (Watts) Airflow (m³/hr) Dry Efficiency % Wet Efficiency % Supply Air Lat C Energy Recovered (Kw) Electric Heater Data Based on maximum airflow 42Kw single or three phase electric supply. LPHW Coil Data Based on maximum airflow and 82/71 C. Maximum heating output 46Kw. Cooling/Heat Pump Coil Data Chilled water/direct expansion coil data based on maximum airflow & chilled 6/12 C or DX 6 C. Max cooling output 45Kw. EQUAL FLOWS ECO DIRECTIVE ErP 2016/2018 COMPLIANT Casework Class Weight (kg) H1 H2 H3 H4 H5 H6 H7 W1 W2 L1 L2 30/25 FG /25 AS /25 PB /25 TS PB /50 FG /50 FG PB /50 FG TS PB /50 AS TS PB /50 AS QS PB NOTE Type 3 (T3) AHPHX Units have a single bottom deck section attached to the type 1 (T1) unit, containing an electric or LPHW heating coil, together with a chilled water or direct expansion cooling coil. A heat pump coil is also available in this section as an option. All as illustrated on the above diagram. 35

36 Selection Chart MODEL AHPHX 2100/T4/ /4F Performance TYPICAL TYPE 4 COMPONENT CONFIGURATION WATTS 2350RPM EC310/390/4F External Pressure Pascals Airflow (m³/hr) Inlet SWL (db) Outlet SWL (db) Absorbed power (Watts) Airflow (m³/hr) Dry Efficiency % Wet Efficiency % Supply Air Lat C Energy Recovered (Kw) Secondary F7 grade Bag Filters Plate Heat Exchanger with by pass Model PHX/W /D Electric Heater Data Based on maximum airflow 30Kw single or three phase electric supply. LPHW Coil Data Based on maximum airflow and 82/71 C. Maximum heating output 36Kw. Cooling/Heat Pump Coil Data Chilled water/direct expansion coil data based on maximum airflow & chilled 6/12 C or DX 6 C. Max cooling output 35Kw. EQUAL FLOWS ECO DIRECTIVE ErP 2016/2018 COMPLIANT Casework Class Weight (kg) H1 H2 H3 H4 H5 H6 H7 W1 W2 L1 L2 30/25 FG /25 AS /25 PB /25 TS PB /50 FG /50 FG PB /50 FG TS PB /50 AS TS PB /50 AS QS PB NOTE Type 3 (T3) AHPHX Units have a single bottom deck section attached to the type 1 (T1) unit, containing an electric or LPHW heating coil, together with a chilled water or direct expansion cooling coil. A heat pump coil is also available in this section as an option. All as illustrated on the above diagram. Section includes a F5 to F7 grade Bag Filter arranged for side withdrawal.

37 Selection Chart MODEL AHPHX 2300/T1/ /4F Performance TYPICAL TYPE 1 COMPONENT CONFIGURATION External Pressure Pascals Airflow (m³/hr) Inlet SWL (db) Outlet SWL (db) Absorbed power (Watts) Airflow (m³/hr) Dry Efficiency % Wet Efficiency % Supply Air Lat C Energy Recovered (Kw) EQUAL FLOWS ECO DIRECTIVE ErP 2016/2018 COMPLIANT 2720WATTS 3000RPM EC310/680/4F Plate Heat Exchanger with by pass Model PHX/W /D Casework Class Weight (kg) H1 H2 H3 H4 H5 H6 H7 W1 W2 L1 30/25 FG /25 AS /25 PB /25 TS PB /50 FG /50 FG PB /50 FG TS PB /50 AS TS PB /50 AS QS PB

38 Selection Chart MODEL AHPHX 2300/T2/ /4F Performance TYPICAL TYPE 2 COMPONENT CONFIGURATION 2720WATTS 3000RPM EC310/680/4F Plate Heat Exchanger with by pass Model PHX/W /D Electric Heater Data Based on maximum airflow 75Kw single or three phase electric supply. LPHW Coil Data Based on maximum airflow and 82/71 C. Maximum heating output 85Kw. External Pressure Pascals Airflow (m³/hr) Inlet SWL (db) Outlet SWL (db) Absorbed power (Watts) Airflow (m³/hr) Dry Efficiency % Wet Efficiency % Supply Air Lat C Energy Recovered (Kw) EQUAL FLOWS ECO DIRECTIVE ErP 2016/2018 COMPLIANT Casework Class Weight (kg) H1 H2 H3 H4 H5 H6 H7 W1 W2 L1 L2 30/25 FG /25 AS /25 PB /25 TS PB /50 FG /50 FG PB /50 FG TS PB /50 AS TS PB /50 AS QS PB NOTE Type 2 (T2) AHPHX Units have a single bottom deck section attached to the type 1 (T1), containing an electric or LPHW Heating Coil as illustrated on the above diagram. 38

39 Selection Chart MODEL AHPHX 2300/T3/ /4F Performance TYPICAL TYPE 3 COMPONENT CONFIGURATION 2720WATTS 3000RPM EC310/680/4F Secondary F7 grade Bag Filters. Plate Heat Exchanger with by pass Model PHX/W /D External Pressure Pascals Airflow (m³/hr) Inlet SWL (db) Outlet SWL (db) Absorbed power (Watts) Cooling/Heat Pump Coil Data Chilled water/direct expansion coil data based on maximum airflow & chilled 6/12 C or DX 6 C. Max cooling output 65Kw. Airflow (m³/hr) Dry Efficiency % Wet Efficiency % Supply Air Lat C Energy Recovered (Kw) EQUAL FLOWS ECO DIRECTIVE ErP 2016/2018 COMPLIANT Electric Heater Data Based on maximum airflow 66Kw single or three phase electric supply. LPHW Coil Data Based on maximum airflow and 82/71 C. Maximum heating output 70Kw. Casework Class Weight (kg) H1 H2 H3 H4 H5 H6 H7 W1 W2 L1 L2 30/25 FG /25 AS /25 PB /25 TS PB /50 FG /50 FG PB /50 FG TS PB /50 AS TS PB /50 AS QS PB NOTE Type 3 (T3) AHPHX Units have a single bottom deck section attached to the type 1 (T1) unit, containing an electric or LPHW heating coil, together with a chilled water or direct expansion cooling coil. A heat pump coil is also available in this section as an option. All as illustrated on the above diagram. Section includes a F5 to F7 grade Bag Filter arranged for side withdrawal. 39

40 Selection Chart MODEL AHPHX 2300/T4/ /4F Performance TYPICAL TYPE 4 COMPONENT CONFIGURATION WATTS 3000RPM EC310/680/4F Secondary F7 Bag Filters. Plate Heat Exchanger with by pass Model PHX/W /D External Pressure Pascals Airflow (m³/hr) Inlet SWL (db) Outlet SWL (db) Absorbed power (Watts) Airflow (m³/hr) Dry Efficiency % Wet Efficiency % Supply Air Lat C Energy Recovered (Kw) EQUAL FLOWS ECO DIRECTIVE ErP 2016/2018 COMPLIANT Electric Heater Data Based on maximum airflow 57Kw single or three phase electric supply. LPHW Coil Data Based on maximum airflow and 82/71 C. Maximum heating output 65Kw. Cooling/Heat Pump Coil Data Chilled water/direct expansion coil data based on maximum airflow & chilled 6/12 C or DX 6 C. Max cooling output 60Kw. Casework Class Weight (kg) H1 H2 H3 H4 H5 H6 H7 W1 W2 L1 L2 30/25 FG /25 AS /25 PB /25 TS PB /50 FG /50 FG PB /50 FG TS PB /50 AS TS PB /50 AS QS PB NOTE Type 3 (T3) AHPHX Units have a single bottom deck section attached to the type 1 (T1) unit, containing an electric or LPHW heating coil, together with a chilled water or direct expansion cooling coil. A heat pump coil is also available in this section as an option. All as illustrated on the above diagram. Section includes a F5 to F7 grade Bag Filter arranged for side withdrawal.

41 Performance Graphs 600 AHPHX 800/ /T1&2/1F 700 AHPHX 1000/ /T1&2/1F External Resistance (PA) External Resistance (PA) External Resistance (PA) Airflow (M 3 /Hr) AHPHX 800/ /T3/1F Airflow (M 3 /Hr) AHPHX 800/ /T4/1F External Resistance (PA) External Resistance (PA) External Resistance (PA) Airflow (M 3 /Hr) AHPHX 1000/T1&2/ /1F Airflow (M 3 /Hr) AHPHX 1000/ /T4/1F Airflow (M 3 /Hr) Airflow (M 3 /Hr) 41

42 Performance Graphs AHPHX 1500/ /T1&2/2F 600 External Resistance (PA) External Resistance (PA) External Resistance (PA) Airflow (M 3 /Hr) AHPHX 1500/T3/ /2F Airflow (M 3 /Hr) AHPHX 1500/ /T4/1F External Resistance (PA) External Resistance (PA) AHPHX 1700/T3/ /2F Airflow (M 3 /Hr) AHPHX 1700/T4/ /2F Airflow (M 3 /Hr) Airflow (M 3 /Hr) 42

43 AHPHX 1700/ /T1&2/2F 600 External Resistance (PA) External Resistance (PA) External Resistance (PA) Airflow (M 3 /Hr) AHPHX 1700/ /T3 3F Airflow (M 3 /Hr) AHPHX 1700/ /T4 3F External Resistance (PA) External Resistance (PA) AHPHX 2000/ /T3 3F Airflow (M 3 /Hr) AHPHX 2000/ /T4 3F Airflow (M 3 /Hr) Airflow (M 3 /Hr) 43

44 Performance Graphs AHPHX 1900/ /T1 & T2 4F 700 External Resistance (PA) AHPHX 1900/ /T3 4F Airflow (M 3 /Hr) Airflow (M 3 /Hr) AHPHX 1900/ /T3 4F Airflow (M 3 /Hr) AHPHX 1900/ /T4 4F Airflow (M 3 /Hr) 44

45 Weatherproofing - External Model For externally mounted AHPHX Compact Units, fully weatherproof construction options are provided, incorporating a pent style roof with directional gradient slopes to protect against rain ingress as illustrated below. Type 1 Type 2 Type 3 Type

46 Standard Weather Cowl Standard weather cowls contain louvre blades to give added weather protection. The cowls are constructed from plastisol plastic coated sheet steel. AHPHX REF WEIGHT KG W D H AHPHX 800/390/1F/ AHPHX 800/390/1F/ AHPHX 1000/680/1F/ AHPHX 1000/680/1F/ AHPHX 1500/390/2F/ AHPHX 1500/390/2F/ AHPHX 1700/680/2F/ AHPHX 1700/680/2F/ AHPHX 1800/390/3F/ AHPHX 1800/390/3F/ AHPHX 2000/680/3F/ AHPHX 2000/680/3F/ AHPHX 2100/390/4F/ AHPHX 2100/390/4F/ AHPHX 2300/680/4F/ AHPHX 2300/680/4F/ Standard Louvre Deep seal weather louvres are provided as standard on fresh air intakes and exhaust air outlets, constructed from anodised aluminium with plastisol plastic coated steel frame. H H AHPHX REF WEIGHT KG W D H AHPHX 800/390/1F/ AHPHX 800/390/1F/ AHPHX 1000/680/1F/ AHPHX 1000/680/1F/ AHPHX 1500/390/2F/ AHPHX 1500/390/2F/ AHPHX 1700/680/2F/ AHPHX 1700/680/2F/ AHPHX 1800/390/3F/ AHPHX 1800/390/3F/ AHPHX 2000/680/3F/ AHPHX 2000/680/3F/ AHPHX 2100/390/4F/ AHPHX 2100/390/4F/ AHPHX 2300/680/4F/ AHPHX 2300/680/4F/ D D W W 46

47 Attenuation All attenuators are provided to match the AHPHX Compact unit and can be supplied as an integral or bolt on arrangement. This is recommended to prevent noise flanking the attenuators, or the need to acoustic lag the ductwork. If the attenuators are positioned away from the noise source (i.e. AHPHX Compact), then duct noise breakout will occur, unless the duct is acoustically lagged to the same high standard, as the AHPHX Casework. Attenuator Performance Insertion losses for different attenuator lengths serving atmospheric and system side, for both integral or bolt on style. Option 1 Splitter absorbers inbuilt into the AHPHX Compact unit Casework which provides a uniform casework appearance, as shown on Figures 2 and 3 on page 47. Option 2 Duct style attenuators with bolt on arrangement as shown below. The splitter absorbers are contained within a galvanized flanged sheet steel duct. Purpose designed bolt on type attenuators have mezz or dolby flanges to match the air handling unit frames, and can have optional inlet/outlet fairings. 47

48 Attenuator Performance 600mm long Model Insertion Loss db Frequency Hz K 2K 4K 8K AHPHX 800/1F/ AHPHX 1000/1F/ AHPHX 1500/2F/ AHPHX 1700/2F/ AHPHX 1800/3F/ AHPHX 2000/3F/ AHPHX 2100/4F/ AHPHX 2300/4F/ Attenuator Performance 900mm long Model Insertion Loss db Frequency Hz K 2K 4K 8K AHPHX 800/1F/ AHPHX 1000/1F/ AHPHX 1500/2F/ AHPHX 1700/2F/ AHPHX 1800/3F/ AHPHX 2000/3F/ AHPHX 2100/4F/ AHPHX 2300/4F/ Attenuator Performance 1200mm long Model Insertion Loss db Frequency Hz K 2K 4K 8K AHPHX 800/1F/ AHPHX 1000/1F/ AHPHX 1500/2F/ AHPHX 1700/2F/ AHPHX 2000/3F/ AHPHX 1900/3F/ AHPHX 2100/4F/ AHPHX 2300/4F/ Attenuator Performance 1500mm long Model Insertion Loss db Frequency Hz K 2K 4K 8K AHPHX 800/1F/ AHPHX 1000/1F/ AHPHX 1500/2F/ AHPHX 1700/2F/ AHPHX 1800/3F/ AHPHX 2000/3F/ AHPHX 2100/4F/ AHPHX 2300/4F/

49 Attenuator Performance 1800mm long Model Insertion Loss db Frequency Hz K 2K 4K 8K AHPHX 800/1F/ AHPHX 1000/1F/ AHPHX 1500/2F/ AHPHX 1700/2F/ AHPHX 1800/3F/ AHPHX 2000/3F/ AHPHX 2100/4F/ AHPHX 2300/4F/ Attenuator s... AHPHX REF W H L WEIGHT (Kg) AHPHX 800/1F/ mm 675mm 600mm 44 AHPHX 1000/1F/ mm 675mm 600mm 53 AHPHX 1500/2F/ mm 675mm 600mm 70 AHPHX 1700/2F/ mm 790mm 600mm 97 AHPHX 1800/3F/ mm 870mm 600mm 85 AHPHX 2000/3F/ mm 870mm 600mm 108 AHPHX 2100/4F/ mm 870mm 600mm 108 AHPHX 2300/4F/ mm 870mm 600mm 144 AHPHX 800/1F/ mm 675mm 900mm 66 AHPHX 1000/1F/ mm 675mm 900mm 80 AHPHX 1500/2F/ mm 675mm 900mm 105 AHPHX 1700/2F/ mm 790mm 900mm 145 AHPHX 1800/3F/ mm 870mm 900mm 127 AHPHX 2000/3F/ mm 870mm 900mm 162 AHPHX 2100/4F/ mm 870mm 900mm 162 AHPHX 2300/4F/ mm 870mm 900mm 216 AHPHX 800/1F/ mm 675mm 1200mm 88 AHPHX 1000/1F/ mm 675mm 1200mm 106 AHPHX 1500/2F/ mm 675mm 1200mm 140 AHPHX 1700/2F/ mm 790mm 1200mm 194 AHPHX 1800/3F/ mm 870mm 1200mm 170 AHPHX 2000/3F/ mm 870mm 1200mm 216 AHPHX 2100/4F/ mm 870mm 1200mm 216 AHPHX 2300/4F/ mm 870mm 1200mm 288 AHPHX 800/1F/ mm 675mm 1500mm 110 AHPHX 1000/1F/ mm 675mm 1500mm 132 AHPHX 1500/2F/ mm 675mm 1500mm 175 AHPHX 1700/2F/ mm 790mm 1500mm 242 AHPHX 1800/3F/ mm 870mm 1500mm 212 AHPHX 2000/3F/ mm 870mm 1500mm 270 AHPHX 2100/4F/ mm 870mm 1500mm 270 AHPHX 2300/4F/ mm 870mm 1500mm 360 AHPHX 800/1F/ mm 675mm 1800mm 132 AHPHX 1000/1F/ mm 675mm 1800mm 159 AHPHX 1500/2F/ mm 675mm 1800mm 210 AHPHX 1700/2F/ mm 790mm 1800mm 291 AHPHX 1800/3F/ mm 870mm 1800mm 255 AHPHX 2000/3F/ mm 870mm 1800mm 324 AHPHX 2100/4F/ mm 870mm 1800mm 324 AHPHX 2300/4F/ mm 870mm 1800mm

50 Acoustic Louvre As an option to attenuators or attenuator cowls on the air intake and discharge of external AHPHX air handling units, acoustic louvres can be used as an alternative method of reducing the atmospheric side air noise. Four different depths are available with the noise reduction, dimensions and weights as shown on pages 51 and 52. Figure 1 Acoustic louvres have four depths, offering a different insertion loss for each depth. The chart on page 51 gives the noise reduction for each depth 300mm, 400mm, 500mm, 600mm. External AHPHX compact with inlet and exhaust acoustic louvres on a Type 4 configuration unit (Fig 1). Figure 2 External AHPHX compact with inlet and exhaust acoustic louvres. Also supply and return air integral attenuators on a Type 1 configuration unit (Fig 2). Figure 3 External AHPHX compact with inlet and exhaust acoustic louvres. Also supply and return air integral attenuators on a Type 3 configuration unit (Fig 3). 50

51 Acoustic Louvre Performance, s... Acoustic Louvre Performance Frequency Hz K 2K 4K 8K Insertion Loss db 300mm Insertion Loss db 400mm Insertion Loss db 500mm Insertion Loss db 600mm Dimensions & Weights HEIGHT WIDTH DEPTH SIDE VIEW PLAN VIEW WAY WAY WIDTH FRONT VIEW AHPHX REF WEIGHT (Kg) W D H AHPHX 800/390/1F/ mm AHPHX 800/390/1F/ mm AHPHX 800/390/1F/ mm AHPHX 800/390/1F/ mm AHPHX 800/390/1F/ mm AHPHX 800/390/1F/ mm AHPHX 800/390/1F/ mm AHPHX 800/390/1F/ mm 51

52 AHPHX REF WEIGHT (Kg) W D H AHPHX 1000/680/1F/ mm AHPHX 1000/680/1F/ mm AHPHX 1000/680/1F/ mm AHPHX 1000/680/1F/ mm AHPHX 1000/680/1F/ mm AHPHX 1000/680/1F/ mm AHPHX 1000/680/1F/ mm AHPHX 1000/680/1F/ mm AHPHX 1500/390/2F/ mm AHPHX 1500/390/2F/ mm AHPHX 1500/390/2F/ mm AHPHX 1500/390/2F/ mm AHPHX 1500/390/2F/ mm AHPHX 1500/390/2F/ mm AHPHX 1500/390/2F/ mm AHPHX 1500/390/2F/ mm AHPHX 1700/680/2F/ mm AHPHX 1700/680/2F/ mm AHPHX 1700/680/2F/ mm AHPHX 1700/680/2F/ mm AHPHX 1700/680/2F/ mm AHPHX 1700/680/2F/ mm AHPHX 1700/680/2F/ mm AHPHX 1700/680/2F/ mm AHPHX 1800/390/3F/ mm AHPHX 1800/390/3F/ mm AHPHX 1800/390/3F/ mm AHPHX 1800/390/3F/ mm AHPHX 1800/390/3F/ mm AHPHX 1800/390/3F/ mm AHPHX 1800/390/3F/ mm AHPHX 1800/390/3F/ mm AHPHX 2000/680/3F/ mm AHPHX 2000/680/3F/ mm AHPHX 2000/680/3F/ mm AHPHX 2000/680/3F/ mm AHPHX 2000/680/3F/ mm AHPHX 2000/680/3F/ mm AHPHX 2000/680/3F/ mm AHPHX 2000/680/3F/ mm AHPHX 2100/390/4F/ mm AHPHX 2100/390/4F/ mm AHPHX 2100/390/4F/ mm AHPHX 2100/390/4F/ mm AHPHX 2100/390/4F/ mm AHPHX 2100/390/4F/ mm AHPHX 2100/390/4F/ mm AHPHX 2100/390/4F/ mm AHPHX 2300/680/4F/ mm AHPHX 2300/680/4F/ mm AHPHX 2300/680/4F/ mm AHPHX 2300/680/4F/ mm AHPHX 2300/680/4F/ mm AHPHX 2300/680/4F/ mm AHPHX 2300/680/4F/ mm AHPHX 2300/680/4F/ mm 52

53 HANDLERS LTD AHTW Compact Heat Recovery Air Handling Unit 1262 Acoustic Testing Laboratory College of Science & Technology BIM & REVIT Engineering Solutions 53

54 PVHRU Max Quiet Packaged Void Heat Reclaim Unit Benefits Low profile from 300mm deep. Up to 90% Heat Recovery efficiency. Outperforms ErP Heating Coil options. LPHW or electric. Cooling coil options chilled water or DX. Heat pump coil options. TM52 compliant. On board controls available. Filtration to F7. Summer by pass facility. High sound reduction casework tested to BS EN ISO (2010) UKAS certified. High performance backward curved centrifugal fans with low specific fan power. Meets BB101 and BB93 Feb Bottom access. Envirofresh 73 Quiet Low Energy, Air Source Heat Pump System, Silenced with Acoustic Treatment as used in Hundreds of Projects Envirofresh 73 Quiet Benefits Meets TM52 for Schools Meets BB93 Feb 2015 Renewable Energy Source BMS Controls Installed in Unit Factory Pre-Commissioned Heating and Cooling from One Source 50% Less CO 2 Production than a Gas Boiler Low Energy Consumption Reduced Site Installation Cost No External Condensing Units, Pipework or wiring Low Noise Emissions with Silenced Compressors High Specification UKAS Certified Low Breakout Casework No Loss of Heating Capacity at Low Temperatures Room Heating and Cooling available at Reduced Air Volumes Tempered Air Supply without Defrosting No Increase in Footprint over Standard AHUs More Pleasant External Appearance than Condensing Unit or Chiller Installations Out Performs From 300mm Deep 54

55 PVU Quiet Packaged Void Unit Benefits Ultra low profile from 300mm Option bag filters to F7 grade Optional mixing box Matching attenuators Tonal noise control Speed regulation 0>10 Volts Heating coils - LPHW and electric Bottom and side access Fully integrated packaged controls Fan motor isolator fitted as standard High airflow / pressure performance Low specific fan power E.C. fans backward curved Constant pressure Vari-Vol variable volume system available High sound reduction casework tested to BS EN ISO (2010) Suspension brackets with vibration control available Cooling coils chilled water/dx/heatpump available Series VSI/VTI Single & Twin Low Profile Quiet Extract Fan Units low Profile Unit Acoustic Testing Laboratory College of Science & Technology Single Fan Series VSI Benefits Low SFP Tonal noise control Matching attenuators Weatherproof options Low noise breakout Meets BB 93 Feb 2015 High sound reduction casework tested to BS EN ISO (2010) Backward curved, low speed, EC fans Attenuators/cowls and acoustic louvre options Auto change over control system for duty and stand by operation on VTI units Suspension brackets with vibration control available Fan motor isolators fitted as standard Variable volume control system - Vari Vol Twin Fan Series VTI Speed regulation 0>10 Volts Bottom and side access Acoustic Testing Laboratory College of Science & Technology 55

56 Product Range... Single Cased Extract Unit VSI Twin Fan Extract Units VTI and ITU Classvent Units Packaged Void Units PVU Vertical Air Handling Units AH Series Modular AHU s IDG Series Indirect Gas Fired AHU s DG Series Direct Gas Fired AHU s HOSP Health Care Specification Hygiene AHU s AHW Welded Frame and Stainless Units TWHR Heat Reclaim AHU s containing Thermal Wheels AHR Heat Recovery AHU s containing Recuperators Freshcool Cooling only Packaged Units Envirofresh Packaged Heat Pump Units Attenuators and Anti-vibration Mounts Acoustic Enclosures and Screens Flat Pack Build and Refurbishment Planned Maintenance and Site Repairs Airflow/Acoustic/Leakage Performance Testing Facility Skidpak Fully Packaged Units Auto Cad, BIM and REVIT Air Handlers Northern Ltd. Alfred Procter House Bute Street, Salford Manchester M50 1DU Other Associated Literature... Sound Advice for Ventilation Plant in Schools. By David Pinchbeck Air Handling Units Acoustic Insulation Performance test Report BSRIA Envirofresh Performance Test Report EcoDesign Directive 2016/18 AUTO CAD 3D BIM REVIT Tel: Fax: sales@airhandlers.net Web: The company reserves the right to make any variation in technical specification to the equipment described, or to withdraw or replace products without prior notification or public announcement. Air Handlers Northern Ltd is continually developing and improving its products. All description, illustrations, drawings and specifications in this publication present only general particulars and shall not form part of any contract. All goods are subject to the company s General Conditions of Sale, a copy is available on request.

AHTW Compact. Heat Recovery Air Handling Unit. BIM & REVIT Engineering Solutions. Acoustic Testing Laboratory College of Science & Technology

AHTW Compact. Heat Recovery Air Handling Unit. BIM & REVIT Engineering Solutions. Acoustic Testing Laboratory College of Science & Technology HANDLERS LTD AHTW Compact Heat Recovery Air Handling Unit 1262 Acoustic Testing Laboratory College of Science & Technology BIM & REVIT Engineering Solutions The Company Air Handlers has been trading since

More information

PVHRU Max Quiet. Engineering Solutions. Packaged Void Heat Reclaim Unit. Acoustic Testing Laboratory College of Science & Technology

PVHRU Max Quiet. Engineering Solutions. Packaged Void Heat Reclaim Unit. Acoustic Testing Laboratory College of Science & Technology AIR HANDLERS LTD PVHRU Max Quiet Packaged Void Heat Reclaim Unit 1262 Acoustic Testing Laboratory College of Science & Technology Engineering Solutions The Company Air Handlers has been trading since May

More information

Series VTI Quiet Cased Twin Extract Fan Unit

Series VTI Quiet Cased Twin Extract Fan Unit AIR HANDLERS LTD Series VTI Quiet Cased Twin Extract Fan Unit 1262 Acoustic Testing Laboratory College of Science & Technology Engineering Solutions The Company Air Handlers have been trading since May

More information

HPR. Heat recovery units. from 700 to m³/h R410A HIGH EFFICIENCY WITH ENTHALPY EXCHANGER AND BUILT-IN HEAT PUMP SYSTEM

HPR. Heat recovery units. from 700 to m³/h R410A HIGH EFFICIENCY WITH ENTHALPY EXCHANGER AND BUILT-IN HEAT PUMP SYSTEM 1 Lmf Clima 216 FERRARO GROUP HPR Heat recovery units HIGH EFFICIENCY WITH ENTHALPY EXCHANGER AND BUILT-IN HEAT PUMP SYSTEM from 7 to 23. m³/h Supporting structure in extruded aluminium profiles and curtain

More information

Swimming Pool CSR2 Heat Recovery Equipment

Swimming Pool CSR2 Heat Recovery Equipment Swimming Pool CSR2 Heat Recovery Equipment LIFETIME WARRANTY OVER 90% HEAT RECOVERY LOW CARBON British manufacturing at its best EcoAir Box is a trademark of IPT +44 (01527) 492770 www.ecoairbox.co.uk

More information

Vent-Axia Roof Units Range Energy Recovery Ventilation (ERV) Range

Vent-Axia Roof Units Range Energy Recovery Ventilation (ERV) Range CI/SfB (57.7) 1st Edition from Vent-Axia Vent-Axia Roof Units Range Energy Recovery Ventilation (ERV) Range Energy Recovery Ventilation (ERV) Range Building on the success of the Sentinel Totus 2 range

More information

1 AIR HANDLING UNIT TYPE AIR ACCESS 75

1 AIR HANDLING UNIT TYPE AIR ACCESS 75 SUPPLY 1 AIR HANDLING UNIT TYPE AIR ACCESS 75 Location : EXTERNAL Position : SIDE BY SIDE SLIDING PANELS for COMPLETE ACCESSIBILITY MULTI SERVICE BULKHEAD for HYDRAULIC AND ELECTRICAL CONNECTIONS Self-supporting

More information

HIGH EFFICIENCY ROTARY WHEEL - HELPING TO SAVE ENERGY AND REDUCE CARBON EMISSIONS.

HIGH EFFICIENCY ROTARY WHEEL - HELPING TO SAVE ENERGY AND REDUCE CARBON EMISSIONS. XBOXER THERMAL WHEEL HEAT RECOVERY UNITS HIGH EFFICIENCY ROTARY WHEEL - HELPING TO SAVE ENERGY AND REDUCE CARBON EMISSIONS. 118 029 2085 8200 XBOXER THERMAL WHEEL BENEFITS HIGH EFFICIENCY Up to 85% efficient

More information

ULTRA LOW ENERGY. VHR Void Series W/I/s TOTAL SFP Typical. Made in the UK. VHR Void Mounted Heat Recovery Units VHR PERFORMANCE OVERVIEW:

ULTRA LOW ENERGY. VHR Void Series W/I/s TOTAL SFP Typical. Made in the UK. VHR Void Mounted Heat Recovery Units VHR PERFORMANCE OVERVIEW: VHR Void Mounted Heat Recovery Units TM.72 W/I/s TOTAL SFP Typical General: Units shall be manufactured from high quality galvanized sheet steel with stainless steel drain trays, acoustic, non-hygroscopic

More information

Guide Specifications. General. Casing. Coil/Drain pan. Fan/Motor

Guide Specifications. General. Casing. Coil/Drain pan. Fan/Motor Guide Specifications General CR-A series ducted concealed chilled water fan coil units have an air flow range from 45 to 3060 cubic meters per hour with a capacity range from kw up to 9 kw. The CR-A series

More information

Highline 260i EC Waterside Fan Coil Unit

Highline 260i EC Waterside Fan Coil Unit Features: Electronically Commutated (EC) fan motor Specific Fan Power of 0.16 to 0.34 at NR Insignificant fan heat gain Designed to operate below NR at External Static Pressures of up to 50Pa Variable

More information

Complete HVAC Capability

Complete HVAC Capability Air Handling Units Brochure 1110 January 2006 Complete HVAC Capability MEA Horizontal Draw-Thru to Size 65 Vertical Draw-Thru to Size 50 1000 to 60,000 CFM Forward Curved or Airfoil Wheels Inlet Vane Option

More information

MODULAR AIR HANDLING UNITS GAH SERIES

MODULAR AIR HANDLING UNITS GAH SERIES MODULAR AIR HANDLING UNITS GAH SERIES 15 Models with Air Flows from 2,250 Cu.m/hr upto 77,800 Cu.m/hr Suitable for both Standard and District Cooling Applications GAH-TC-10-13 CONTENTS Design 2 Various

More information

HRS. Very high efficiency heat recovery units. from 300 to m³/h >90 % WITH HIGH EFFICIENCY HEAT RECOUPERATOR

HRS. Very high efficiency heat recovery units. from 300 to m³/h >90 % WITH HIGH EFFICIENCY HEAT RECOUPERATOR 4 Lmf Clima 6 FERRARO GROUP HRS Very high efficiency heat recovery units WITH HIGH EFFICIENCY HEAT RECOUPERATOR from 3 to 4. m³/h Air-handling unit designed and manufactured for nonresidential applications,

More information

AIR HANDLING UNITS. Customisable modular air handling unit, designed and built to suit your project requirements

AIR HANDLING UNITS. Customisable modular air handling unit, designed and built to suit your project requirements AIR HANDLING UNITS Customisable modular air handling unit, designed and built to suit your project requirements PacAir Modular Air Handling Units by are customisable, designed and built for n, New Zealand

More information

AIR VENT T E C H N O L O G Y. infinity. energy efficient - environmentally friendly - economical EC MOTORS - direct drive - CuSTOM built ErP Compliant

AIR VENT T E C H N O L O G Y. infinity. energy efficient - environmentally friendly - economical EC MOTORS - direct drive - CuSTOM built ErP Compliant infinity AIR VENT T E C H N O L O G Y energy efficient - environmentally friendly - economical EC MOTORS - direct drive - CuSTOM built ErP Compliant INDEX Selection Chart Page 3 Internal & External Acoustic

More information

BRIZA 22 HYBRID HEATING & COOLING

BRIZA 22 HYBRID HEATING & COOLING BRIZA 22 HYBRID HEATING & COOLING Built-in Ceiling: BABC/BT BABC/FT Built-in Wall: BABW/BT BABW/BF BABW/FT BABW/FF INFO SHEET BRIZA 22 HYBRID, COMPACT FANCOIL With EC Greentech EBM-PAPST technology Europe

More information

DOUBLE SKIN MODULAR AIR HANDLING UNIT. Round Edge (ADM-AHU)

DOUBLE SKIN MODULAR AIR HANDLING UNIT. Round Edge (ADM-AHU) DOUBLE SKIN MODULAR AIR HANDLING UNIT Round Edge (ADM-AHU) AIR HANDLING UNIT Acson Double Skin Modular Air Handling Unit is designed based on a modular concept, making it suitable for breaking down into

More information

PRODUCT SELECTION DATA. Performance. Flexibility. Intelligence. Energy optimisation. Acoustic optimisation. Drycoolers 09PE

PRODUCT SELECTION DATA. Performance. Flexibility. Intelligence. Energy optimisation. Acoustic optimisation. Drycoolers 09PE PRODUCT SELECTION DATA Performance Flexibility Intelligence Energy optimisation Acoustic optimisation Drycoolers 09PE Translation of the original document N 20030, 02.2017 Use 09PE The 09PE range is particularly

More information

Versatility. Features. By installing the SILENT MV, you will never experience the disturbance of noisy ventilation again. Benefits

Versatility. Features. By installing the SILENT MV, you will never experience the disturbance of noisy ventilation again. Benefits Ultra quiet and low profile helicocentrifugal in-line fans suitable for a wide range of domestic and commercial applications. Fitted with sound absorbent insulation and manufactured with an adjustable

More information

product selection data Performance Flexibility Intelligence Energy optimisation Acoustic optimisation Drycoolers - Air-cooled condensers 09PE

product selection data Performance Flexibility Intelligence Energy optimisation Acoustic optimisation Drycoolers - Air-cooled condensers 09PE product selection data Performance Flexibility Intelligence Energy optimisation Acoustic optimisation Drycoolers - 09PE Translation of the original document N 20030, 03.2015 Use The 09PE range, available

More information

UTA STANDARD. Ductable units. Range. Air handling unit with high available static pressure. NEW Eco-Design Filter. V3000 control Fresh air management

UTA STANDARD. Ductable units. Range. Air handling unit with high available static pressure. NEW Eco-Design Filter. V3000 control Fresh air management Ductable units NEW Eco-Design Filter Air handling unit with high available static pressure V3000 control Fresh air management The range of air handling units is designed for suspended ceiling heating and

More information

Heat Exchangers. Evaporator Catalogue

Heat Exchangers. Evaporator Catalogue Heat Exchangers Evaporator Catalogue Version 30: January 2015 Heat Exchangers Thermocoil Catalogue V30 2015 Evaporators Page 2 INDEX EVAPORATORS PAGE Evaporator Design and Info 4 Quick Find List (Sorted

More information

CONFIGURABLE HIGH-EFFICIENCY HEAT RECOVERY UNITS CADB/T-HE PRO-REG Series

CONFIGURABLE HIGH-EFFICIENCY HEAT RECOVERY UNITS CADB/T-HE PRO-REG Series False-ceiling models CADB/T-HE 4 to 33 Heat Recovery Compact heat recovery unit with high-efficiency (up to 93%) counter-flow heat exchanger, EUROVENT certified. The casing is made from plasticised galvanised

More information

Fan - Powered Terminal Unit Series Flow

Fan - Powered Terminal Unit Series Flow 5/22/M/1 Fan - Powered Terminal Unit Series Flow Type TFP Trox (Malaysia) Sdn Bhd 20 Persiaran Bunga Tanjung 1 Senawang Land Industrial Park 70400 Seremban Negeri Sembilan Darul Khusus Malaysia Telephone

More information

^áêëçåâ=ìåáí=åççäéêë=qvoj^ pí~åç~êç=åççäéêë=ïáíü=pí~áåäéëë=píééä=íìäáåö

^áêëçåâ=ìåáí=åççäéêë=qvoj^ pí~åç~êç=åççäéêë=ïáíü=pí~áåäéëë=píééä=íìäáåö ^áêëçåâ=ìåáí=åççäéêë= pí~åç~êç=åççäéêë=ïáíü=pí~áåäéëë=píééä=íìäáåö O `çåíéåíë= page Model indication................................ 2 Eurovent...................................... 2 Capacities.....................................

More information

VLH 504 to Air-to-Water Reverse Cycle Heat Pumps. 126 to 294 kw. 133 to 307 kw

VLH 504 to Air-to-Water Reverse Cycle Heat Pumps. 126 to 294 kw. 133 to 307 kw Air-to-Water Reverse Cycle Heat Pumps VLH 504 to 1204 126 to 294 kw 133 to 307 kw Technical Brochure TM VLH-N.3GB Date : June 2005 Supersedes : TM VLH-N.2GB/07.04 Specifications Advantages Range extension

More information

HRH. High efficiency heat recovery units. from 300 to m³/h >70 % WITH HIGH EFFICIENCY HEAT RECOUPERATOR

HRH. High efficiency heat recovery units. from 300 to m³/h >70 % WITH HIGH EFFICIENCY HEAT RECOUPERATOR 4 Lmf Clima 6 HRH High efficiency heat recovery units WITH HIGH EFFICIENCY HEAT RECOUPERATOR from 3 to 4.3 m³/h The HRH units have been designed for non-residential applications for which a forced and

More information

fåçìëíêá~ä=~áê=åççäéêë=qvo pí~åç~êç=åççäéêë=ïáíü=ëí~áåäéëë=ëíééä=íìäáåö

fåçìëíêá~ä=~áê=åççäéêë=qvo pí~åç~êç=åççäéêë=ïáíü=ëí~áåäéëë=ëíééä=íìäáåö fåçìëíêá~ä=~áê=åççäéêë= pí~åç~êç=åççäéêë=ïáíü=ëí~áåäéëë=ëíééä=íìäáåö O `çåíéåíë= page Model indication..................................2 Eurovent.......................................2 Capacities......................................2

More information

SILENT MV Ultra Quiet In-line Fans

SILENT MV Ultra Quiet In-line Fans Ultra Quiet In-line Fans 5 IP44 2 YEAR GUARANTEE Ultra quiet and low profile helicocentrifugal in-line fans suitable for a wide range of domestic and commercial applications. Fitted with sound absorbent

More information

NEW Slimpak EC Box Fan (SLPT EC)

NEW Slimpak EC Box Fan (SLPT EC) NEW Slimpak EC Box Fan (SLPT EC) Compact low profile design Duct Sizes 100 500mm Performance - Airflow 0.01 to 1.2m 3 /s, Pressure up to 650Pa Latest energy saving EC/DC motors Internal mounting IPX2 Manufactured

More information

product selection data Slim design Acoustic comfort 40% smaller footprint Drycoolers 09VE

product selection data Slim design Acoustic comfort 40% smaller footprint Drycoolers 09VE product selection data Slim design Acoustic comfort 40% smaller footprint Drycoolers 09VE Translation of the original document N 20033, 03.2015 Drycoolers Use Drycoolers in this range are mainly designed

More information

Sentinel D-Box Twin Fan

Sentinel D-Box Twin Fan Sentinel D-Box Twin Fan Duct Sizes mm Performance - Airflow.1 to 1.3m 3 /s, Pressure up to 65Pa Sentinel demand ventilation fan controller with lockable isolator Latest energy saving EC/DC motors Aluzinc

More information

University of Delaware

University of Delaware SECTION 23 36 00 _ SUMMARY PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Constant/Variable volume supply terminal units. 2. Fan powered terminal units. 3. Exhaust valves B. Related Sections: Section

More information

Twin and Single Inline Fans. Offers a range of flexible installation and application options, including auto-changeover on the Twin range

Twin and Single Inline Fans. Offers a range of flexible installation and application options, including auto-changeover on the Twin range Twin and Single Inline Fans Offers a range of flexible installation and application options, including auto-changeover on the Twin range 2 Version 3.1 Breathing Buildings Inline Box Fans Demand Control

More information

Features: Concealed installation. Compact design. Available in electric, LPHW or ambient.

Features: Concealed installation. Compact design. Available in electric, LPHW or ambient. Features: Concealed installation. Compact design. Available in electric, LPHW or ambient. Grille can be supplied in a large range of colours. Energy saving controls option available. Application The Diffusion

More information

TECHNICAL DOCUMENTATION WOLF AIR HEATERS LH-EC / LH. 30m 3 /h

TECHNICAL DOCUMENTATION WOLF AIR HEATERS LH-EC / LH. 30m 3 /h TECHNICAL DOCUMENTATION WOLF AIR HEATERS LH-EC / LH 30m 3 /h THE EXTENSIVE EQUIPMENT RANGE from system supplier WOLF offers the ideal solution for commercial and industrial buildings, new build and modernisation

More information

technical sales guide - 60Hz Ducted Split Units HIGH AMBIENT OPERATION 52 UPTO

technical sales guide - 60Hz Ducted Split Units HIGH AMBIENT OPERATION 52 UPTO technical sales guide - 60Hz Taurus R Ducted Split Units UPTO HIGH AMBIENT OPERATION 52 O C Page CONTENTS Nomenclature.. 2 Description. 3 Features.. 3 Product Data. 4 Condensing Unit Cooling Performance

More information

HIGH TEMPERATURE TWIN SQUIF FANS

HIGH TEMPERATURE TWIN SQUIF FANS HIGH TEMPERATURE FANS HIGH TEMPERATURE FOR SMOKE EXTRACT CERTIFIED TO EN12101-3-2002. 374 029 2085 8200 BENEFITS QUIET AND POWERFUL SOLUTIONS High performance centrifugal motor/impeller combination providing

More information

AIR HANDLING UNIT. MODEL: PM0809 to PM CFM to CFM

AIR HANDLING UNIT. MODEL: PM0809 to PM CFM to CFM AIR HANDLING UNIT MODEL: PM0809 to PM2738 700CFM to 41000 CFM POWER METAL TECHNOLOGIES (M) SDN BHD Lot 37830, Jalan Bukit Naga, Kampung Bukit Naga, Section 32, 40460 Shah Alam, Selangor Darul Ehsan. Tel:

More information

50 Hz AIR - COOLED SPLIT SYSTEM. Products That Perform...By People Who Care AIR CONDITIONERS WITH SCROLL COMPRESSORS

50 Hz AIR - COOLED SPLIT SYSTEM. Products That Perform...By People Who Care AIR CONDITIONERS WITH SCROLL COMPRESSORS R FORM NO: MS0305F Products That Perform...By People Who Care AIR - COOLED SPLIT SYSTEM AIR CONDITIONERS WITH SCROLL COMPRESSORS 50 Hz COOLING CAPACITY- 60 MBH TO 1360 MBH ACCS SERIES HEB-D, EB-D SERIES

More information

Air Cooled Packaged Units

Air Cooled Packaged Units Air Cooled Packaged Units Technical Data OPA 465, OPA 550, OPA 705, OPA 855, OPA 960 (ECO) Cooling Capacity 44.9kW - 96.0kW Heating Capacity 41.1kW - 90.0kW Contents OPA 465 960 ECO 3 General 3 Applications

More information

Modular Air Handling. Up to 3,500 Litres / sec. Low profile & Plant room application. Draft. Version. Second Edition A-. AirDesign 2015 AirDesign 2016

Modular Air Handling. Up to 3,500 Litres / sec. Low profile & Plant room application. Draft. Version. Second Edition A-. AirDesign 2015 AirDesign 2016 Modular Air Handling U n i t R a n g e Up to 3,500 Litres / sec Low profile & Plant room application AirDesign 2015 AirDesign 2016 Second Edition Draft Version A-. Air Design is a proud Australian based

More information

Sentinel D-Box Single Fan

Sentinel D-Box Single Fan Sentinel D-Box Single Fan Duct size to 5mm Performance - Airflow.1 to 1.6m 3 /s Pressure up to 65Pa Sentinel demand ventilation fan controller with lockable isolator Aluzinc contstruction suitable for

More information

NEW Acoustic In-Line Fans (ACQ)

NEW Acoustic In-Line Fans (ACQ) NEW Acoustic In-Line Fans (ACQ) Acoustically treated housing, Class O rated, sandwich construction selected for maximum noise absorption Motors protected to IP44 Motor insulation Class B Maximum operating

More information

SPECIFICATIONS AND DESIGN ARE SUBJECT TO CHANGE WITHOUT PRIOR NOTICE. EDITION 11

SPECIFICATIONS AND DESIGN ARE SUBJECT TO CHANGE WITHOUT PRIOR NOTICE. EDITION 11 AIR HANDLING UNIT (DOUBLE SKIN) MODEL: DS-CW/DX-AHU-H (Chilled Water or Direct Expansion) CAPACITY: 3.3 to 125 Nominal Tons 39,000 to 1,500,000 BtuH 11.4 to 439.5 KW 1,300 to 50,000 CFM Benefits Horizontal

More information

AHN 064 to 304 EHN/CHN 064 to 304

AHN 064 to 304 EHN/CHN 064 to 304 u Horizontal Packaged and Split Air Conditioners AHN 64 to 34 EHN/CHN 64 to 34 6. to 29.2 kw 6.4 to 29.4 kw Engineering Data Manual EDM AECHN-A.1GB Date : June 28 Supersedes : None Technical Description

More information

ELTAFANTECH Air Handling Unit 700 up to 42,000 CFM

ELTAFANTECH Air Handling Unit 700 up to 42,000 CFM an ELTA GROUP company ELTAFANTECH 700 up to 42,000 CFM INNOVATIVE Design & Performance INTRODUCTION There are 24 standard sizes of optimally engineered s to handle air volumes from 700 CFM to 42,000CFM.

More information

Trench Heating/Cooling. Katherm HK. Tested acc. to: BS EN 16430

Trench Heating/Cooling. Katherm HK. Tested acc. to: BS EN 16430 Trench Heating/Cooling Katherm HK Tested acc. to: BS EN 16430 Improved performance The narrower trench width and shallower trench height of the totally redesigned Katherm HK delivers an optimised output

More information

CODE MODEL 1RC9020 REC PRO 90 S RC9021 REC PRO 90 S RC9022 REC PRO 90 S RC9023 REC PRO 90 S

CODE MODEL 1RC9020 REC PRO 90 S RC9021 REC PRO 90 S RC9022 REC PRO 90 S RC9023 REC PRO 90 S REC PRO 9S High efficiency Heat Recovery Units Non residential applications EFFICIENCY 9% Comply with ErP Directive 125/29/CE and EU Regulation 1253/214. Classification: Non Residential Ventilation Unit

More information

technical catalogue tetris KW Chiller and heat pumps air/water

technical catalogue tetris KW Chiller and heat pumps air/water technical catalogue tetris 110 930 KW Chiller and heat pumps air/water > TETRIS Water chiller > TETRIS /HP Reversible heat pump > TETRIS /ST Water chiller with storage tank and pumps > TETRIS /DC Unit

More information

Chassis Access Fans Motors Speed Control Coils The Condensate Tray Insulation Spigots Controls Enclosure Control Valves Filters Rev A

Chassis Access Fans Motors Speed Control Coils The Condensate Tray Insulation Spigots Controls Enclosure Control Valves Filters Rev A Chassis panelwork is all In House manufactured from nominally 1.2mm Galvanised steel. Where at all possible, flanges are formed inward facing to prevent exposure to bare metal edges. Sufficient forms and

More information

D M S 760 C01 A A 1 1

D M S 760 C01 A A 1 1 CONTENTS Description Features Options Available Selection Method Product Data Cooling Performance Data (85 F Ambient Cooling Performance Data (95 F Ambient) Cooling Performance Data (105 F Ambient)..............................

More information

CLOSE CONTROL UNITS WITH CHILLED WATER COIL

CLOSE CONTROL UNITS WITH CHILLED WATER COIL CLOSE CONTROL UNITS WITH CHILLED WATER COIL COOLING CAPACITY FROM 5 TO 154 kw 230 D 56 The range of chilled water close control units, series, is particularly indicated for use in technological centres,

More information

AQVSL/AQVSH STAR 85 to 140

AQVSL/AQVSH STAR 85 to 140 Chiller QVSL/ STR 85 to 140 ir Cooled Water Chillers Cooling Only and Heat Pump Engineering Data Manual 82 to 157 kw 83 to 168 kw Outstanding Strength Points Units with R410 refrigerant (it will be the

More information

Integreret Combi Cooler system Energieffektiv ventilation og køling. FCUA Fancoil

Integreret Combi Cooler system Energieffektiv ventilation og køling. FCUA Fancoil Integreret Combi Cooler system Energieffektiv ventilation og køling FCUA Fancoil DESCRIPTION The FCU(A,F) fan coil unit is a highperformance, cost-effective and compact solution for the cooling of technical

More information

HIGH EFFICIENCY HEAT RECOVERY UNITS WITH ROTARY WHEEL RHE Series

HIGH EFFICIENCY HEAT RECOVERY UNITS WITH ROTARY WHEEL RHE Series High efficient units up to 88% with rotary wheel, plug-fans with backward curved blades and EC external-rotor motor. Pre-configured control system for easy start-up. The casing is made of 5 mm, self-supporting

More information

MAJOR 2 NCH. Ductable units. High pressure and high capacity ductable units RANGE NCH Y NCH NCH I COADIS COMBI. Motor optional

MAJOR 2 NCH. Ductable units. High pressure and high capacity ductable units RANGE NCH Y NCH NCH I COADIS COMBI. Motor optional Y + U I COADIS COMBI High pressure and high ductable units Motor optional is a non independent air conditioning terminal unit for heating and cooling offices and hotels. With reduced dimensions and designed

More information

Square Mixed Flow Fans (MFQ)

Square Mixed Flow Fans (MFQ) Square Mixed Flow Fans (MFQ) Features and Benefits Motors protected to IP44 Motor insulation Class B Maximum operating temperature +40 C Standard Thermal Overload Protection Sizes 400 to 500 3 phase are

More information

MAJAX-2 GENERAL SPECIFICATION

MAJAX-2 GENERAL SPECIFICATION MAJAX-2 GENERAL SPECIFICATION Majax-2 axial flow fans are manufactured in diameters ranging from 315mm to 2000mm (available in 2250mm on request), and incorporate manually adjustable pitch aluminium bladed

More information

Uniclass L7534. Manufacture controlled to ISO9001

Uniclass L7534. Manufacture controlled to ISO9001 CABINET & TWIN FANS FOR INDUSTRIAL / COMMERCIAL USE "ACFS" - Quiet Duct Centrifugal - Single Fan "DMTSQ" - Quiet Duct Centrifugal - Twin Fan "RMS" - Roof Centrifugal - Single Fan "RMTS" - Roof Centrifugal

More information

VLS (Cooling Only) VLH (Heat Pump Version) VLR (Total Heat Recovery Version)

VLS (Cooling Only) VLH (Heat Pump Version) VLR (Total Heat Recovery Version) R u Air Cooled Water Chillers VLS (Cooling Only) VLH (Heat Pump Version) VLR (Total Heat Recovery Version) Models 524 to 1204 137 to 308 kw 150 to 336 kw Engineering Data Manual EDM VL410-W.2GB Date :

More information

Resolair 64 and 68. Comfort air conditioning unit with highly efficient regenerative heat storage packages. AIR VOLUME FLOW: 3,900 23,100 m³/h

Resolair 64 and 68. Comfort air conditioning unit with highly efficient regenerative heat storage packages. AIR VOLUME FLOW: 3,900 23,100 m³/h Comfort air conditioning unit with highly efficient regenerative heat storage packages 68 10 01 - simplified illustration Automatically selects the most economical operating mode! 64 and 68 AIR OLUME FLOW:

More information

BACKWARD CURVE CENTRIFUGAL FANS KABB / KABT Series

BACKWARD CURVE CENTRIFUGAL FANS KABB / KABT Series Cabinet fans manufactured from galvanised steel sheet with double thickness side panels lined with 17 mm thickness of fireproof fibreglass acoustic insulation (M0). Circular duct connection flange on the

More information

GUIDE SPECIFICATIONS. ES Series R-410A

GUIDE SPECIFICATIONS. ES Series R-410A GUIDE SPECIFICATIONS ES Series R-410A GENERAL Units shall be performance certified to ISO standard 13256-1 for Water Loop Pump, Ground Water Pump and Ground Loop Pump applications. Units shall be Underwriter

More information

R410A. Packaged Air Source Heat Pump AHU. A packaged solution developed with simplicity and energy efficiency in mind.

R410A. Packaged Air Source Heat Pump AHU. A packaged solution developed with simplicity and energy efficiency in mind. Packaged Air Source Heat Pump AHU Heat recovery Integral heating and cooling Direct driven fans with EC motors Digital compressors Integrated control system Compact footprint Air volumes from 0.75m 3 /s

More information

fåçìëíêá~ä=~áê=åççäéêë=qelo pí~åç~êç=åççäéêë=ïáíü=`ì=íìäáåö

fåçìëíêá~ä=~áê=åççäéêë=qelo pí~åç~êç=åççäéêë=ïáíü=`ì=íìäáåö = pí~åç~êç=åççäéêë=ïáíü=`ì=íìäáåö O `çåíéåíë= page Model indication..................................2 Eurovent.......................................2 Capacities......................................2

More information

CS3 Series 50/60Hz. Modular Central Station Air Handling Units Air Volume: 1000 to cfm (1700 to m 3/hr)

CS3 Series 50/60Hz. Modular Central Station Air Handling Units Air Volume: 1000 to cfm (1700 to m 3/hr) CS3 Series 50/60z Modular Central Station Air andling Units Air Volume: 1000 to 56000 cfm (1700 to 90 m 3/hr) Products that perform...by people who care DUNAM-BUS CS3 Series Introduction For more than

More information

CRH RANGE - TECHNICAL DATA CENTRIFUGAL ROOF FANS

CRH RANGE - TECHNICAL DATA CENTRIFUGAL ROOF FANS ge 2 CENTRIFUGAL CRH RANGE - TECHNICAL ROOF DATA FANS FOR INDUSTRIAL / COMMERCIAL USE CRH - Horizontal Discharge CRV - Vertical Discharge CRL - Low Profile Uniclass L7534 Tel: +44 ()1494 522333 Fax: Vectaire

More information

SECTION AIR TERMINAL UNITS

SECTION AIR TERMINAL UNITS SECTION 23 36 00 AIR TERMINAL UNITS PART 1 - GENERAL 1.1 SUMMARY A. Section includes constant volume terminal units, variable volume terminal units, dual duct terminal units, fan powered terminal units,

More information

Hybrid. DUTIES UP TO 0.95 m 3 /s (950 l/s) Ecovent Hybrid part of a complete range of innovative, flexible products from the HVAC experts

Hybrid. DUTIES UP TO 0.95 m 3 /s (950 l/s) Ecovent Hybrid part of a complete range of innovative, flexible products from the HVAC experts Ecovent Hybrid ffmeets BB101 and FOS overheat requirements, through mechanical ventilation mode ffdesigned to meet BB93 requirements ffutilises natural ventilation and has low specific fan power in mechanical

More information

Küba SG industrial

Küba SG industrial 66 Küba Blue Line : Specific advantages The is a master of customisation. No matter how great the demand for power, the is the answer. Its versatility allows the Küba SG industrial to master the most complex

More information

ACOUSTIC CABINET FANS CVB / CVT Series

ACOUSTIC CABINET FANS CVB / CVT Series Cabinet fans manufactured from heavy gauge galvanised steel sheet and internally lined with melamine foam flame retardant acoustic insulation (M1). All models incorporate double inlet single phase direct-drive

More information

Hydropac. Waterside Control Fan Coil Units For Horizontal and Vertical Applications. June Hydropac. Features

Hydropac. Waterside Control Fan Coil Units For Horizontal and Vertical Applications. June Hydropac. Features June 2003 Hydropac Hydropac Waterside Control Fan Coil Units For Horizontal and Vertical Applications Features Flush panel extra rigid construction. Low noise levels. Eleven speed transformer. Full acoustic

More information

VERTICAL SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING WITH HOT WATER OR ELECTRIC HEAT

VERTICAL SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING WITH HOT WATER OR ELECTRIC HEAT VERTICAL SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING WITH HOT WATER OR ELECTRIC HEAT SIZES FROM 600 TO 4,000 All Technical Specifications are Subject to Change without Notice.

More information

HEAT-RECOVERY UNITS WITH ENTHALPY/ROTARY HEAT EXCHANGER TECHNICAL MANUAL

HEAT-RECOVERY UNITS WITH ENTHALPY/ROTARY HEAT EXCHANGER TECHNICAL MANUAL UT REC - R HEAT-RECOVERY UNITS WITH ENTHALPY/ROTARY HEAT EXCHANGER TECHNICAL MANUAL 1 CONTENTS GENERAL FEATURES... 3 Scope of the unit... 3 Available configurations... 3 Description of the components...

More information

PRO Rental Product Range. PRO275-2 (EUIIIa Compliant) KEY FEATURES. Rental Ready Features. Alternator. Integrated Voltage Regulator (IVR) Enclosure

PRO Rental Product Range. PRO275-2 (EUIIIa Compliant) KEY FEATURES. Rental Ready Features. Alternator. Integrated Voltage Regulator (IVR) Enclosure PRO275-2 (EUIIIa Compliant) 50/60Hz Switchable Rating Prime Product 275 kva / 220 kwe KEY FEATURES Rental Ready Features Forklift pockets Fully certified dual point lifting Integrated heavy duty drag bar

More information

SLH 1202 to Air-to-Water Reverse Cycle Heat Pumps. With Screw Compressors. 261 to 775 kw. 287 to 853 kw

SLH 1202 to Air-to-Water Reverse Cycle Heat Pumps. With Screw Compressors. 261 to 775 kw. 287 to 853 kw Air-to-Water Reverse Cycle Heat Pumps SLH 1202 to 3804 With Screw Compressors 261 to 775 kw 287 to 853 kw Technical Brochure TM SLH-A.2GB Date : November 2004 Supersedes : TM SLH-A.1GB/05.04 Design Features

More information

1/11 29/06/2016 CONTENTS 1. GENERAL DUCTS, AIR VENTS, VALVES MONOBLOCK UNITS FILTRATION CONTROL...

1/11 29/06/2016 CONTENTS 1. GENERAL DUCTS, AIR VENTS, VALVES MONOBLOCK UNITS FILTRATION CONTROL... 1/11 29/06/2016 VENTILATION AND Buildings & Technical Services Section AIR-CONDITIONING STANDARD CONTENTS 1. GENERAL... 2 2. DUCTS, AIR VENTS, VALVES... 2 3. MONOBLOCK UNITS... 3 4. FILTRATION... 5 5.

More information

DIRECT-AIR ILB / ILT Series Rectangular duct fans

DIRECT-AIR ILB / ILT Series Rectangular duct fans IN-LINE DUCT FAN Series Rectangular duct fans Range of in-line rectangular duct fan manufactured from galvanised steel sheet and provided with an inspection cover that can be removed to access the motor/impeller

More information

ITEC High Efficiency EC Twin Fan for convenient fitting and full control. Casing constructed from 1.6mm Galvanised sheet steel

ITEC High Efficiency EC Twin Fan for convenient fitting and full control. Casing constructed from 1.6mm Galvanised sheet steel ITEC High Efficiency EC Twin Fan for convenient fitting and full control Casing constructed from 1.6mm Galvanised sheet steel Circular spigot connection Inline for ease of fitting into duct system Single

More information

BRIZA EC 12 HYBRID. World s slimmest fan coil HEATING AND COOLING

BRIZA EC 12 HYBRID. World s slimmest fan coil HEATING AND COOLING World s slimmest fan coil wall and ceiling installation 2-or 4-Pipe system heating and / or cooling with or without enclosure easy installation 24VDC EC motor silent, powerful, economical, sustainable

More information

The Straight Way. Rectangular Cabinet Fan. Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and heating Products Tunnel Fans

The Straight Way. Rectangular Cabinet Fan. Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and heating Products Tunnel Fans Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and heating Products Tunnel Fans The Straight Way Rectangular Cabinet Fan Systemair India Pvt. Ltd. certifies that the Rectangular

More information

PACKAGE UNIT PCA340U TECHNICAL SELECTION DATA. -10 o C UNIT FEATURES SPECIFICATION SUMMARY UNIT OPTIONS CONTROL OPTIONS UNIT COMPLIANCE.

PACKAGE UNIT PCA340U TECHNICAL SELECTION DATA. -10 o C UNIT FEATURES SPECIFICATION SUMMARY UNIT OPTIONS CONTROL OPTIONS UNIT COMPLIANCE. TECHNICAL SELECTION DATA PACKAGE UNIT + o C -10 o C 3 THREE PHASE SCROLL TWO STAGE CENTRIFUGAL LOUVRE LIANT SCROLL RESSOR AXIAL UNIT FEATURES SPECIFICATION SUMMARY Scroll Compressor Multiple Speed Outdoor

More information

42CET/ 42CED Series Chilled Water Fan Coil Unit Furred-in Ceiling Model 300 to 1400 cfm Electric heater option

42CET/ 42CED Series Chilled Water Fan Coil Unit Furred-in Ceiling Model 300 to 1400 cfm Electric heater option 42CET/ 42CED Series Chilled Water Fan Coil Unit Furred-in Ceiling Model 0 to 10 cfm Electric heater option 42DC/ 42DCD Series Chilled Water Fan Coil Unit Furred-in Ceiling Model 0 to 00 cfm Electric heater

More information

VAV TERMINAL BOXES TYPE: BA BT

VAV TERMINAL BOXES TYPE: BA BT Installation dimensions View inlet side View outlet side C G F E ø D A 65 ø8 B 25 Side view Top view 40 150 150 L1 Application ø D 150 Size operating range q (m 3 /h) Min. Max. Nom. 125 90 150-440 500

More information

Select the right heating or cooling coil for your project! Instantly size and cost your chosen coil with the SPC2000 coil-selection program.

Select the right heating or cooling coil for your project! Instantly size and cost your chosen coil with the SPC2000 coil-selection program. www.spcoils.co.uk SPC2000 Coil Selection Program User guide V2.1 Select the right heating or cooling coil for your project! Instantly size and cost your chosen coil with the SPC2000 coil-selection program.

More information

Air-Cooled Liquid Chiller with integrated hydraulic module

Air-Cooled Liquid Chiller with integrated hydraulic module Air-Cooled Liquid Chiller with integrated hydraulic module Cooling only: CGAN 200-250 - 300-400 - 450-490 - 500-600 - 700-800 - 900-925 Reversible: CXAN 200-250 - 300-400 - 450-490 - 500-600 - 700-800

More information

AQVL (Cooling Only Version) AQVH (Heat Pump Version)

AQVL (Cooling Only Version) AQVH (Heat Pump Version) R u Air Cooled Water Chillers (Cooling Only Version) (Heat ump Version) Models 85 to 140 84 to 137 kw 92 to 146 kw Engineering Data Manual EDM AQV-W.1GB Date : November 2009 Supersedes : None High erformance

More information

CHP

CHP Packaged Unit Heat Pump CHP16-024-030-036-048-060 2-5 Ton Cooling 23,000-57,500 Btuh Heating 12,800-85,300 Btuh (5-25 kw) Optional Electric Heating FEATURES Designed for outdoor rooftop or ground level

More information

Shut-off dampers. Type AK-Ex. For low-leakage shut-off of volume flows in potentially. explosive atmospheres (ATEX) PD AK-Ex 1.

Shut-off dampers. Type AK-Ex. For low-leakage shut-off of volume flows in potentially. explosive atmospheres (ATEX) PD AK-Ex 1. X X testregistrierung Shut-off dampers Type ATEX-compliant parts and units For low-leakage shut-off of volume flows in potentially explosive atmospheres (ATEX) Circular shut-off dampers for shutting off

More information

Expert Design...Trusted Power

Expert Design...Trusted Power Expert Design...Trusted Power 350 750 kva Range Performance I Durability I Serviceability A new power standard has arrived. The 350 750 kva range from FG Wilson is designed by our expert engineers to

More information

MAKING REFRIGERATION GREENER

MAKING REFRIGERATION GREENER Searle KME air cooler MAKING RERIGERATION GREENER The Searle KME cooler range from Kelvion is ideally suited to large cold rooms and small warehouses where an efficient cooling solution is required. The

More information

ACOUSTIC CABINET FANS CVAB / CVAT Series

ACOUSTIC CABINET FANS CVAB / CVAT Series Range of in-line cabinet fans, manufactured from galvanised steel sheet with double thickness side panels internally lined with 17 mm thickness of fireproof fibreglass acoustic insulation (M). All models

More information

EC Motor MultiZone Fan Coil Units. IXDL-Y Series l/s

EC Motor MultiZone Fan Coil Units. IXDL-Y Series l/s EC Motor MultiZone Fan Coil Units IXDL-Y Series 00 000 l/s Company Profile Temperzone Limited is a leading manufacturer and distributor of quality air conditioning and ventilation products throughout the

More information

CGAM. Air-cooled scroll chiller. Accessories. Customer benefits. Tracer CH530 Control. Main features. Energy saving options.

CGAM. Air-cooled scroll chiller. Accessories. Customer benefits. Tracer CH530 Control. Main features. Energy saving options. CGAM Air-cooled scroll chiller Customer benefits Life cycle effectiveness Efficiency and sound level without compromise All year round operation Extreme reliability and durability Wide application flexibility

More information

ROOF FAN ROOFMASTER STEC NON-INSULATED VERSION TECHNICAL CATALOGUE

ROOF FAN ROOFMASTER STEC NON-INSULATED VERSION TECHNICAL CATALOGUE ROOF FAN ROOFMASTER STEC NON-INSULATED VERSION TECHNICAL CATALOGUE Roofmaster STEC non-insulated version - Technical Catalogue 3 CONTENTS GENERAL DESCRIPTION Application/specification...4 Features...4

More information

VAHU Vertical Air Handling Unit

VAHU Vertical Air Handling Unit 500 to 5,400 CFM @ up to 6.00" TSP 2" double wall construction, perforated or solid lined 18 gauge G90 galvanized steel cabinet 4 standard cabinet sizes available Internally isolated direct drive plug

More information

VARYCONTROL VAV Dual Duct Terminal Boxes

VARYCONTROL VAV Dual Duct Terminal Boxes 5/2/B/3 VARYCONTROL VAV Dual Duct Terminal Boxes for variable volume systems Type TVM Trox (U.K.) Ltd Caxton Way GB-Thetford Norfolk IP24 3SQ Telephone +44 (0)1842 754545 Telefax +44 (0)1842 7051 www.troxuk.co.uk

More information

BOX BLB Centrifugal Box Fan

BOX BLB Centrifugal Box Fan Centrifugal Box Fan Select models available for next day delivery Product Overview 3 sizes from 260mm to 400mm Air volume flow rates up to 0.751m³/s Static pressures up to 733 Pa Suitable for operating

More information