OUTDOOR LIGHTING

Size: px
Start display at page:

Download "OUTDOOR LIGHTING"

Transcription

1 Sheet 1 of 1 TLE OF CONTENTS GENERL INFORMTION HID LMPS PHOTOCONTROLS LUMINIRE COMPONENTS NEM HED LUMINIRE COMPONENTS HORIZONTL LUMINIRE COMPONENTS LED RCKET MOUNT LUMINIRES LUMINIRE COMPONENTS HID DECORTIVE (POST TOP) LUMINIRE COMPONENTS LED DECORTIVE (POST TOP) LUMINIRES LUMINIRE COMPONENTS HID DIRECTIONL (FLOOD) LUMINIRE COMPONENTS LED DIRECTIONL (FLOOD) LUMINIRES MULTIPLE INSTLLTION ON WOOD POLE MULTIPLE INSTLLTION ON WOOD LINE POLE OVE COMMUNICTIONS MULTIPLE INSTLLTION, ORNMENTL CONCRETE POLE, OVERHED CIRCUIT, DEDEND MULTIPLE INSTLLTION, ORNMENTL CONCRETE POLE, OVERHED CIRCUIT, TNGENT, NGLE MULTIPLE INSTLLTION, ORNMENTL CONCRETE POLE, UG CIRCUIT FIERGLSS POLE, 30 ND 35, UG CIRCUIT FIERGLSS POLE, 30 ND 35, OH CIRCUIT, TNGENT, NGLE OR DE DIRECTIONL FLOOD ON WOOD POLE MULTIPLE CLE TERMINTION RISER FOR DIRECT URIED CIRCUIT POST TOP INSTLLTION ON FIERGLSS POLE STREET LIGHTING POLE/CONDUIT STREET LIGHTING, SPLICE OX INSTLLTION OF UG STREET LIGHT CLE ON WOOD POLE MULTIPLE INSTLLTION, 30 REKWY POLE, UG CIRCUIT OUTDOOR LIGHT TGGING MO ONLY MO ONLY ** ** ** ** ** ** ** ** ** ** ** ** ** ** ** ** ** REV. DTE: 12/26/2017

2 General Information Sheet 1 of General General information concerning outdoor lighting installations is covered in this section. 2.0 Standard Luminaires 2.1 racket Mount (rea) Luminaires ll new installations will be made using Light Emitting Diode (LED) equivalent bracket mount luminaires. The existing High Pressure Sodium (HPS), Pulse-start Metal Halide (PMH), probe-start Metal Halide (MH) and Mercury Vapor (MV) luminaires are no longer available, and may remain in-service until the Luminaire, Lamp or Photocontrol failure. 2.1 Directional (Flood) Luminaires ll new installations will be made using LED equivalent directional (flood) luminaires. The existing HPS, PMH, MH and MV luminaires are no longer available, and may remain in-service until the Luminaire, Lamp or Photocontrol failure. 2.2 Decorative (Post-Top) Luminaires In Missouri all new lighting installations will be made using LED luminaires. The existing HPS, PMH, MH and MV luminaires are no longer available, and may remain in-service until the Luminaire failure. Illinois all new lighting installations will be made using HPS and PMH luminaires. The existing MH and MV luminaires are no longer available, and may remain in-service until the Luminaire failure. The list of available Luminaires: STOCK NUMER STYLE STTE LMP WTTS LED 100 W EQUIVLENT RCKET MOUNT LUMINIRE IES LIGHT PTTERN racket Mount MO LED 39 II, FIG racket Mount MO LED 39 V, FIG racket Mount IL LED 39 II, FIG racket Mount IL LED 39 V, FIG. 3 LED 250 W EQUIVLENT RCKET MOUNT LUMINIRE racket Mount MO LED 137 III, FIG. 2 VOLTS 120V/208V/ 240V/277V 120V/208V/ 240V/277V 120V/208V/ 240V/277V 120V/208V/ 240V/277V 120V/208V/ 240V/277V CORRL. COLOR TEMP. (3) (KELVIN) LUMENS STRT/ OP MPS VOLTGE INPUT RNGE PF % , ±5% 99% , ±5% 99% , ±5% 99% , ±5% 99% , ±5% 99% racket Mount MO LED 137 III, FIG V , ±5% 99% racket Mount IL LED 107 III, FIG V/208V/ 240V/277V , ±5% 99% racket Mount IL LED 107 III, FIG V , ±5% 99% LED 400 W EQUIVLENT RCKET MOUNT LUMINIRE racket Mount MO LED 195 III, FIG. 2 TLE 1. VILLE LUMINIRES 120V/208V/ 240V/277V , ±5% 100% racket Mount MO LED 195 III, FIG V , ±5% 100% ENG: WW REV: 11 REV. DTE: 09/01/2017

3 General Information Sheet 2 of 10 STOCK NUMER STYLE STTE LMP WTTS IES LIGHT PTTERN racket Mount IL LED 190 III, FIG. 2 VOLTS 120V/208V/ 240V/277V CORRL. COLOR TEMP. (3) (KELVIN) LUMENS STRT/ OP MPS VOLTGE INPUT RNGE PF % , ±5% 100% racket Mount IL LED 190 III, FIG V , ±5% 100% LED 250W EQUIVLENT DIRECTIONL/FLOOD LUMINIRE Directional MO LED 98 6X6 120/208/ 240/277V , ±10% 90% Directional MO LED 98 6X V , ±10% 90% Directional IL LED 98 6X6 120/208/ 240/277V , ±10% 90% Directional IL LED 98 6X V , ±10% 90% LED 400W EQUIVLENT DIRECTIONL/FLOOD LUMINIRE Directional MO LED 150 6X6 120/208/ 240/277V , ±10% 90% Directional MO LED 150 6X V , ±10% 90% Directional IL LED 150 6X6 120/208/ 240/277V , ±10% 90% Directional IL LED 150 6X V , ±10% 90% LED 1000W EQUIVLENT DIRECTIONL/FLOOD LUMINIRE Directional MO LED 297 6X Rectangular IL LED 44 III, FIG Rectangular IL LED 136 III, FIG. 2 LED 400W EQUIVLENT RECTNGULR (SHOEOX) LUMINIRE Rectangular IL LED 183 III, FIG /208/ 240/277V 120/208/ 240/277V 120/208/ 240/277V 120/208/ 240/277V , ±10% 90% , ±10% 90% , ±10% 90% , ±10% 90% Rectangular IL LED 183 III, FIG V , ±10% 90% HID DECORTIVE/POST-TOP LUMINIRE TLE 1. VILLE LUMINIRES (CONTINUED) LED 100W EQUIVLENT RECTNGULR (SHOEOX) LUMINIRE LED 250W EQUIVLENT RECTNGULR (SHOEOX) LUMINIRE Early merican IL / MO HPS 100 III, FIG V 1,900K 9, /2.1 ±5% 45% Early merican IL / MO HPS 100 V, FIG V 1,900K 9, /2.1 ±5% 45% (1,2) Early merican IL MH 175 III, FIG V 4,100K 14, /1.75 ±10% 45% (2) Early merican IL PMH 150 III, FIG V 4,100K 12,900 - ±10% 45% corn IL HPS 100 V, FIG V 1,900K 9, /2.1 ±5% 45% (1,2) corn IL MH 175 V, FIG V 4,100K 14, /1.75 ±10% 45% (2) corn IL PMH 150 V, FIG V 4,100K 12, /0.9 ±10% 45% ENG: WW REV: 11 REV. DTE: 09/01/2017

4 General Information Sheet 3 of 10 STOCK NUMER STYLE STTE LMP WTTS IES LIGHT PTTERN VOLTS CORRL. COLOR TEMP. (3) (KELVIN) LUMENS STRT/ OP MPS VOLTGE INPUT RNGE Colonial MO HPS 100 III, FIG V 1,900K 9, /2.1 ±5% 45% Colonial MO HPS 100 V, FIG V 1,900K 9, /2.1 ±5% 45% Contemporary or Traditional Contemporary or Traditional TLE 1. VILLE LUMINIRES (CONTINUED) MO HPS 100 III, FIG V 1,900K 9, /2.1 ±5% 45% MO HPS 100 V, FIG V 1,900K 9, /2.1 ±5% 45% spen MO HPS 100 III, FIG V 1,900K 9, /2.1 ±5% 45% spen MO HPS 100 V, FIG V 1,900K 9, /2.1 ±5% 45% PF % LED 100W EQUIVLENT DECORTIVE/POST-TOP LUMINIRE Early merican MO LED 52 III, FIG Early merican MO LED 52 V, FIG Colonial MO LED 44 III, FIG Colonial MO LED 44 V, FIG Contemporary or Traditional Contemporary or Traditional MO LED 50 III, FIG. 2 MO LED 50 V, FIG spen MO LED 39 III, FIG spen MO LED 39 V, FIG /208/ 240/277V 120/208/ 240/277V 120/208/ 240/277V 120/208/ 240/277V 120/208/ 240/277V 120/208/ 240/277V 120/208/ 240/277V 120/208/ 240/277V , ±10% 88% , ±10% 88% , ±10% 88% , ±10% 88% , ±10% 94% , ±10% 94% , ±10% 96% , ±10% 96% NOTES: 1. Probe-start Metal Halide (MH) luminaires with solid red identification tag are obsolete. These luminaires require MH lamp and may remain in service until Luminaire failure. 2. Pulse-start Metal halide (PMH) Lamps are NOT interchangeable with probe-start Metal Halide (MH) Lamps. If a PMH lamp is installed in the MH luminaire, the lamp will not ignite or will not start. If a MH lamp is installed in the PMH luminaire, the lamp will ignite or start very quickly. The MH lamp is not designed to run on the PMH ballast and will experience a very short lamp life. ecause of the high startup voltage that is delivered across the ballast by the ignitor to the lamp, the lamp is subject to a non-passive end of life and could rupture the lamp arch tube. It is very important to always close the luminaire optical before testing the lamp or starting the MH/PMH luminaire. 3. Correlated Color Temperature (CCT) is the measure of light source color appearance in degrees Kelvin. ENG: WW REV: 11 REV. DTE: 09/01/2017

5 General Information Sheet 4 of Lighting Patterns SIDEWLK STREET OR LLEY SIDEWLK FIGURE 1 Type II - The type II distribution is used for lighting alleys and smaller streets. The light beam is narrow and long. LED 100W EQUIVLENT RCKET MOUNT TYPE II LUMINIRE SIDEWLK STREET SIDEWLK FIGURE 2 Type III - The type III distribution is used for lighting the larger roadways, general parking areas and other areas where a larger area of lighting is required. LED 250W & 400W EQUIVLENT RCKET MOUNT TYPE III LUMINIRE LUMINIRE (TYP.) FIGURE 3 Type V - The type V distribution is used for lighting intersections, center islands of parkway, cul-de-sacs, and fields. The light beam has even intensity at all angles. LED 100W EQUIVLENT RCKET MOUNT TYPE V LUMINIRE ENG: WW REV: 11 REV. DTE: 09/01/2017

6 General Information Sheet 5 of Identification ll luminaires are shipped with the appropriate NEM identification decal. If the decal is not installed it should be re-applied on the fixture so that it can be seen from the ground. NEM DECL 3" MIN. 3" MIN. 101/4" 2" MIN " MIN. 10 TYPE V LED 3" MIN V LED 3/4" MIN V LED TLE 2. IDENTIFYING CODE IDENTIFYING NUMERL LMP WTTGE ND LED EQUIVLENT CKGROUND COLOR LMP TYPE W GOLD HIGH PRESSURE SODIUM (HPS) W *HLF RED/HLF WHITE PULSE-STRT METL HLIDE (PMH) W LUE MERCURY VPOR (MV) W RED PROE-STRT METL HLIDE (MH) W GOLD HIGH PRESSURE SODIUM (HPS) X W RED PROE-STRT METL HLIDE (MH) W EQV. WHITE LIGHT EMITTING DIODE (LED) 10 TYPE V 100 W EQV. WHITE LIGHT EMITTING DIODE (LED) W EQV. WHITE LIGHT EMITTING DIODE (LED) V 250 W EQV. WHITE LIGHT EMITTING DIODE (LED) W EQV. WHITE LIGHT EMITTING DIODE (LED) V 400 W EQV. WHITE LIGHT EMITTING DIODE (LED) X W EQV. WHITE LIGHT EMITTING DIODE (LED) ENG: WW REV: 11 REV. DTE: 09/01/2017

7 General Information Sheet 6 of 10 PROE STRT METL HLIDE MH *HORIZONTL URN PULSE STRT METL HLIDE PMH *VERTICL URN PULSE STRT METL HLIDE PMH * PMH Luminaires label with wattage identification code. The first label on the left is horizontal burn PMH luminaire such as horizontal non-cutoff, horizontal cutoff, and directional flood luminaires. The label on the right is for vertical burn PMH luminaire such as post-top luminaires. 5.0 Luminaire Mounting Heights Post-top luminaires shall be mounted only on fiberglass poles purchased specifically for that purpose. ll other types of luminaires shall be mounted in accordance with the following table. The preferred height should be maintained whenever possible but the minimum heights may be used if this avoids a pole replacement. Mounting height is defined as the height from ground to the bottom of the refractor (glassware) on glass enclosed reflectors and to the bottom of the lamp on open type reflectors. LIGHT EMITTING DIODE (LED) LED 100 W EQUIVLENT RCKET MOUNT LED 250 W EQUIV. DIRECT. LED 400 W EQUIV. DIRECT. LED 250 W EQUIVLENT RCKET MOUNT LED 250 W EQUIVLENT RCKET MOUNT LED 400 W EQUIVLENT RCKET MOUNT LED 400 W EQUIVLENT RCKET MOUNT LED 1000 W EQUIV. DIRECT. 6.0 rackets HIGH PRESSURE SODIUM (HPS) W HPS POST-TOP TLE 3. LUMINIRE MOUNTING HEIGHTS PROE-STRT (MH) ND PULSE-STRT (PMH) METL HLIDE 150 W PMH POST-TOP 175 W MH POST-TOP 100 W HPS OPEN OTTOM 100 W HPS HORIZ. COR HED W HPS DIRECTIONL 250 W MH & PMH DIRECTIONL 400 W HPS DIRECTIONL 400 W MH & PMH DIRECTIONL W MH & PMH HORIZONTL COR HED 250 W HPS HORIZONTL COR HED 400 W HPS HORIZONTL COR HED W MH & PMH HORIZONTL COR HED W MH DIRECTIONL MIN. MTG. HEIGHT [FT.] PREF. MTG. HEIGHT [FT.] Standard installations for area lights shall use the 30 bracket. Standard installations for street lights shall use the 6 bracket. rackets must be ordered as a separate item along with the luminaire and all other components and hard-ware. For special applications, other brackets are available but their usage should be limited as much as possible. The following data is for use in determining bracket locations to provide luminaire mounting heights as specified in the proceeding section. ll upsweep brackets and mast arms are equipped for 1-1/4 slip-fitter mounting of luminaires ENG: WW REV: 11 REV. DTE: 09/01/2017

8 General Information Sheet 7 of 10 C C C L UPPER MEMER 30" ND 6' RCKETS DRWING NOT TO SCLE 15' MST RM DRWING NOT TO SCLE 24" TWO 5/8" DI. THRUOLT C L LOWER MEMER TLE 4. RCKET ND MST RM LENGTH/DIMENSIONS RCKET LENGTH C 30 11" Ornamental concrete pole are no longer meren s standards and they are replaced with fiberglass poles for maintenance. Ornamental concrete pole have a set bracket mounting point. For these concrete poles the height above ground level at the luminaire end of the bracket is per following table: TLE 5. LUMINIRE HEIGHT OVE GROUND LEVEL - CONCRETE POLES CONCRETE POLES STOCK NUMER POLE HIGHT OVE THE GROUNG LUMINIRE HEIGHT T THE END OF THE 6 FT. RCKETS EXISTING - MINTENNCE ONLY 23' 25'-3" EXISTING - MINTENNCE ONLY 28' 30'-3" 6.2 For both horizontal and vertical burning luminaires, the distance from the mounting point to the bottom of the luminaire is approximately 12. For fiberglass mast arm poles per material spec , the height above ground level, at the luminaire end of the bracket is per following table: TLE 6. LUMINIRE HEIGHT OVE GROUND LEVEL - FIERGLSS POLES FIERGLSS POLES STOCK NUMER POLE HIGHT OVE THE GROUNG LUMINIRE HEIGHT T THE END OF THE 6 FT. RCKETS ' 26'-3" ' 28'-3" ' 31'-3" ' 33'-3" ENG: WW REV: 11 REV. DTE: 09/01/2017

9 General Information Sheet 8 of Remote Operated and Multiple Light Control Periodically, light from one luminaire will activate the photocell and shut off another light. For these circumstances, when simply re-aiming the photocell does not resolve the problem, a remote photocell mounting bracket is used. In some circumstances, it is beneficial to operate multiple luminaires from one control. For these circumstances a remote photocell mounting bracket or relay is used. In both of the above situations, the photocell on the luminaire is replaced with a shorting plug. The photocell is rated at 15 while the relay is rated at 30. See Table 1 of this document, for current draw information in order to determine how many luminaires can be controlled by either the photocell or the relay. If multiple luminaires are used on 3-wire, single phase circuits, care should be taken to balance the load between the two phases in order to have the lights operated at the same time. POLE LCK-120V SUPPLY NEUTRL POLE LCK RED-SWITCHED LEG WHITE WHITE RED MULTIPLE LIGHT CONTROL DIGRM * STOCK NUMER STTE MO/IL DESCRIPTION PHOTOCELL, V, 1000 W FIL ON, LCK, NORTH ORIENTED, HEVY DUTY (LONG LIFE, 20+ YERS) MO/IL PLUG, SHORTING, PHOTOELECTRIC CELL MO/IL TLE 7. MULTIPLE LIGHT CONTROL MTERIL PHOTOCELL RCKET ND PHOTOCELL RECEPTCLE SSEMLY MOUNTING ON POLE OR CROSSRM W/RECEPTCLE MO/IL RELY, 120 V, 30 MULTIPLE STREETLIGHTS *For more information on photocontrol see DCS ENG: WW REV: 11 REV. DTE: 09/01/2017

10 General Information Sheet 9 of References Chart Missouri STOCK NUMER LED LUMINIRE TLE 8. LUMINRE EQUIVLENT WTTGES - RCKET MOUNT LUMINIRES - MISSOURI LUMINIRE I.D. LIGHT EMITTING DIODE (LED) MERCURY VPOR (MV) HID FIXTURE WTTGE METL HLIDE (MH) PULSE-STRT (PMH) HIGH PRESS. SODIUM (HPS) VOLTGE MO W 100/150/175/250 W 150 W & 175 W 70 W & 100 W 120/208/240/277 V MO 10 TYPE V 39 W 100/150/175/250 W 150 W & 175 W 70 W & 100 W 120/208/240/277 V MO W 400 W 250 W 250 W 120/208/240/277 V MO V 140 W 400 W 250 W 250 W 480 V MO W 1000 W 400 W 400 W 120/208/240/277 V MO V 195 W 1000 W 400 W 400 W 480 V STOCK NUMER LED LUMINIRE TLE 9. LUMINRE EQUIVLENT WTTGES - DIRECTIONL (FLOOD) LUMINIRES - MISSOURI LUMINIRE I.D. WTTGE LIGHT EMITTING DIODE (LED) MERCURY VPOR (MV) METL HLIDE (MH) PULSE-STRT (PMH) HIGH PRESS. SODIUM (HPS) MO W 400 W 250 W & 400 W (1) 250 W 120/208/240/277 V MO V 98 W 400 W 250 W & 400 W (1) 250 W 480 V MO W 1000 W MO V 150 W 1000 W - HID FIXTURE WTTGE VOLTGE (1) 400 W 120/208/240/277 V (1) 400 W 480 V MO X1 300 W W 1000 W 120/208/240/277 V NOTES: 1. In Missouri only the 400 W Pulse Start Metal Halide (PMH) and probe start Metal Halide (MH) directional (flood) luminaires will be replaced with the LED 250 W equivalent luminaire. ENG: WW REV: 11 REV. DTE: 09/01/2017

11 General Information Sheet 10 of References Chart Illinois STOCK NUMER LED LUMINIRE TLE 10. LUMINRE EQUIVLENT WTTGES - RCKET MOUNT LUMINIRES - ILLINOIS LUMINIRE I.D. LIGHT EMITTING DIODE (LED) MERCURY VPOR (MV) HID FIXTURE WTTGE METL HLIDE (MH) PULSE-STRT (PMH) HIGH PRESS. SODIUM (HPS) VOLTGE IL W 100/150/175/250 W 150 W & 175 W 70 W & 100 W 120/208/240/277 V IL 10 TYPE V 39 W 100/150/175/250 W 150 W & 175 W 70 W & 100 W 120/208/240/277 V IL W 400 W 250 W 250 W 120/208/240/277 V IL V 107 W 400 W 250 W 250 W 480 V IL W 1000 W 400 W 400 W 120/208/240/277 V IL V 190 W 1000 W 400 W 400 W 480 V ENCLOSED COR HED, SEMI CUTOFF 120 V, V ND 480 V ENCLOSED COR HED, CUTOFF 120 V, V ND 480 V OPEN OTTOM/NEM HED 120 V LED 100 W, 250 W ND 400 W EQUIVLENT RCKET MOUNT LUMINIRE STOCK NUMER LED LUMINIRE TLE 11. LUMINRE EQUIVLENT WTTGES - DIRECTIONL (FLOOD) LUMINIRES - ILLINOIS LUMINIRE I.D. WTTGE LIGHT EMITTING DIODE (LED) MERCURY VPOR (MV) HID FIXTURE WTTGE METL HLIDE (MH) PULSE-STRT (PMH) HIGH PRESS. SODIUM (HPS) VOLTGE IL W 400 W 250 W 250 W 120/208/240/277 V IL V 98 W 400 W 250 W 250 W 480 V IL W 1000 W 400 W 400 W 120/208/240/277 V IL V 150 W 1000 W 400 W 400 W 480 V ENG: WW REV: 11 REV. DTE: 09/01/2017

12 HID LMPS Sheet 1 of 2 1. High Pressure Sodium (HPS) Lamps CLER HPS lamps must be used only in luminaires with ballasts designed for HPS lamps. HPS lamps require at least 1 minute to restrike after a power interruption. Standard lamp sizes and types are as follows: vg. Rated Life pprox. Initial Stock No. Lamp Watts Lamp Type (HRS) Lumens Lamp ase HPS 24,000+ 6,300 Mogul HPS 24,000+ 9,500 Mogul HPS 24, ,000 Mogul HPS 24, ,000 Mogul HPS 24, ,000 Mogul HPS 24, ,000 Mogul 2. Probe Start Metal Halide (MH) Lamps (Replacement for the existing probe start metal halide (MH) luminaires) MH lamps must be used only in luminaires ballasts designed for MH lamps. MH lamps require approximately 7 to 12 minutes to restrike after a power interruption. Standard lamp sizes and types are as follows: vg. Rated Life pprox. Initial Stock No. Lamp Watts Lamp Type (HRS) Lumens Lamp ase MH 10,000 14,400 Mogul MH 7,500 20,000 Mogul MH 15,000 32,000 Mogul MH 12, ,800 Mogul 3. Pulse Start Metal Halide Lamps (PMH) (Use in Pulse start metal halide (PMH) luminaire) PMH lamps must be used only in luminaires ballasts designed for PMH lamps. PMH lamps require approximately 5 to 7 minutes to restrike after a power interruption. Standard lamp sizes and types are as follows: vg. Rated Life pprox. Initial Stock No. Lamp Watts Lamp Type (HRS) Lumens Lamp ase PMH 16,000 9,000 Medium PMH 12,000 12,900 Medium PMH 12,000 19,000 Mogul PMH 20,000 40,000 Mogul ENG:WYW REV. NO: NEW REV. DTE: 01/21/10

13 HID LMPS Sheet 2 of 2 4. Mercury Vapor (MV) Lamps (Replacement for existing mercury vapor luminaires only) MV lamps must be used only in luminaires with ballasts designed for MV lamps. MV lamps require at least 6 minutes to restrike after a power interruption. Standard lamp sizes and types are as follows: vg. Rated Life pprox Initial Stock No. Lamp Watts Lamp Type (HRS) Lumens Lamp ase MV 24,000+ 8,500 Mogul MV 24, ,000 Mogul MV 24, ,000 Mogul MV 24, ,000 Mogul IMPORTNT 1. PMH lamps are not interchangeable with MH lamps. 2. If a PMH lamp is placed inside of a MH luminaire, the lamp will not ignite or will not start. 3. If a MH lamp is placed inside of a PMH luminaire, the lamp will ignite or start very quickly. The MH lamp is not designed to run on the PMH ballast and will experience a very short lamp life. ecause of the high start up voltage that is delivered across the ballast by the ignitor to the lamp, the lamp is subject to a non passive end of life and could rupture the lamp arc tube. It is very important to always close the fixture optical before testing the lamp or starting the MH/PMH luminaire. 4. MV and MH/PMH lamps may continue to operate for some time even though the out glass envelope is missing. These lamps should be removed from service as soon as possible since they are a source of ultraviolet radiation when operating in this condition. 5. ll PMH lamps and HPS lamps (not LU/plus) cycle at end of life. ENG:WYW REV. NO: NEW REV. DTE: 01/21/10

14 Photocontrols Sheet 1 of 1 FIGURE 1 FIGURE 2 FIGURE " WLL THICKNESS 2.55" CLER WINDOW 2.47" 1.12" 3.25" 3.16" 3.16" HEVY DUTY LONG LIFE STNDRD DUTY UPWRD LOOKING ILLINOIS ONLY SHORTING COVER STOCK NUMER STTE VOLTGE TLE 1. LIGHT CONTROL MTERIL DESCRIPTION (1,3,4) MO/IL V PHOTOCELL, 1000W; FIL ON (1,3,4) MO/IL 480V PHOTOCELL, 1000W; FIL ON (2,3,4) IL 120V PHOTOCELL, UPWRD LOOKING, 1000W; FIL ON MO/IL - PLUG, SHORTING, PHOTOELECTRIC CELL HOUSING HOUSING COLOR WINDOW TYPE STYLE FIG. NO. LCK NORTH HEVY DUTY ORIENTED (LONG LIFE, 20+ YERS) FIG. 1 YELLOW NORTH HEVY DUTY ORIENTED (LONG LIFE, 20+ YERS) FIG. 1 CLER UPWRD STNDRD DUTY (10+ YERS) FIG TWISTLOCK RECEPTCLE FIG. 3 NOTES: 1. Long life-heavy duty photocell must be used with Light Emitting Diode (LED) luminaire. 2. Upward looking photocontrol to be used ONLY when necessary to prevent mis-operation due to a point source of ambient light entering the photocontrol window. May be needed in area with a large number of lights where the light from one luminaire causes another to turn off. 3. Photocontrol must have instantaneous turn on and 3-5 second turn off delay. 4. See Material Specification for more information. ENG: ZSD REV. NO: 2 REV. DTE: 06/30/2017

15 Luminaire Components, NEM Head ** Sheet 1 of 1 C D Stnd. / Stk. No. Description Lamp HPS 70W Lamp HPS 100W Hood HPS 70W Hood HPS 100W 1 1 C Refl. W/O crylic (III) Refl. W/O crylic (V) 1 1 D Switch 100W PE Cell ENG:WYW REV. NO: 5 REV. DTE: 07/09/10

16 Luminaire Components Horizontal ** Sheet 1 of 3 NON CUTOFF CUTOFF HPS Standard 100W, 120V, Type III, Non Cutoff W, 120V, Type III, Cutoff W, 120V, Type III, Non Cutoff W, 120V, Type III, Cutoff W, 120V, Type III, Non Cutoff W, 120V, Type III, Cutoff Metal Halide Probe Start (MH) (1) (4) Standard 250W, 120V, Type III, Cutoff W, 120V, Type III, Non Cutoff W, 120V, Type III, Cutoff W, 120V, Type III, Non Cutoff Stnd. / Stk. No. Description ** Lamp HPS 100W Lamp, HPS, 250W Lamp, MH, 250W Lamp, HPS, 400W Lamp, MH, 400W Luminaire, 100W, 120V, HPS, NCO Luminaire, 100W, 120V, HPS, CO Luminaire, 250W, 120V, HPS, NCO Luminaire, 250W, 120V, HPS, CO 1 1, Luminaire, 250W, 120V, MH, CO 1 1, Luminaire, 250W, 120V, MH, NCO Luminaire, 400W, 120V, HPS, NCO Luminaire, 400W, 120V, HPS, CO 1 1, Luminaire, 400W, 120V, MH, CO 1 1, Luminaire, 400W, 120V, MH, NCO 1 C Switch, St. Lt., 1000W, 120/240/277V, P.E ENG:WYW REV. NO: 6 REV. DTE: 02/08/11

17 Luminaire Components Horizontal ** Sheet 2 of 3 NON CUTOFF CUTOFF HPS (4) Standard 250W, 480V, Type III, Cutoff W, 480V, Type III, Non Cutoff W, 120/208/240/277, Non Cutoff W, 480V, Type III, Non Cutoff W, 480V,Type III, Cutoff W, 120/208/240/277V, Type III, Type III, Non Cutoff Metal Halide Pulse Start (PMH) (2) (4) Standard 250W, 120V, Type III, Cutoff W, 120V, Type III, Non Cutoff W, 120V, Type III, Cutoff W, 120V, Type III, Non Cuotff Stnd. / Stk. No. Description ** Lamp HPS 250W Lamp, HPS, 400W Lamp PMH 250W Lamp PMH 400W Luminaire, 250W, 480V,HPS, CO Luminaire, 250W, 480V,HPS, NCO Luminaire, 250W, 120/208/240/277V, HPS, NCO Luminaire, 400W, HPS, SCO, 480V Luminaire, 400W, HPS, CO, 480V Luminaire, 400W, 120/208/240/277V, HPS, NCO 1 2, Luminaire, 250W, 120V, PMH, CO 1 2, Luminaire, 250W, 120V, PMH, NCO 1 2, Luminaire, 400W, 120V, PMH, CO 1 2, Luminaire, 400W, 120V, PMH, NCO 1 C Switch, St. Lt., 1000W, 120/240/277V, P.E Switch, St. Lt., 1000W, 480V, P.E ENG:WYW REV. NO: 6 REV. DTE: 02/08/11

18 Luminaire Components Horizontal ** Sheet 3 of 3 NON CUTOFF CUTOFF HPS (lack) (3) Standard 250W, 120V, Type III, Cutoff W, 120V, Type III, Non Cutoff Stnd. / Stk. No. Description ** Lamp HPS 250W Lamp, HPS, 400W Luminaire, 250, 120V,HPS, CO Luminaire, 250, 120V,HPS, NCO 1 C Switch, St. Lt., 1000W, 120/240/277V, P.E. 1 1 Notes: 1. Metal Halide Probe start (MH) Luminaires are no longer available from supplier. 2. Metal Halide Pulse start (PMH) Luminaires are to replace the obsolete MH Luminaires. 3. Stock items are available in MO only. 4. Stock item is available in IL only. ENG:WYW REV. NO: 6 REV. DTE: 02/08/11

19 ** Luminaire Components - LED racket Mount Luminaires Sheet 1 of 1 LED 100W, 250W ND 400W EQUIVLENT RCKET MOUNT LUMINIRE DESCRIPTION: MEREN MO, 4000K STNDRD LED 100W EQ., 120V-277V, TYPE II LED 100W EQ., 120V-277V, TYPE V LED 250W EQ., 120V-277V, TYPE III LED 250W EQ., 480V, TYPE III LED 400W EQ., 120V-277V, TYPE III LED 400W EQ., 480V, TYPE III DESCRIPTION: MEREN IL, 3000K STNDRD LED 100W EQ., 120V-277V, TYPE II LED 100W EQ., 120V-277V, TYPE V LED 250W EQ., 120V-277V, TYPE III LED 250W EQ., 480V, TYPE III LED 400W EQ., 120V-277V, TYPE III LED 400W EQ., 480V, TYPE III STOCK STTE DESCRIPTION NUMER LUMINIRE, LED 100W EQUIV., MO 1 120V-277V, TYPE II, 4000K LUMINIRE, LED 100W EQUIV., MO 1 120V-277V, TYPE V, 4000K LUMINIRE, LED 250W EQUIV., MO 1 120V-277V, TYPE III, 4000K LUMINIRE, LED 250W EQUIV., MO 1 480V, TYPE III, 4000K LUMINIRE, LED 400W EQUIV., MO 1 120V-277V, TYPE III, 4000K LUMINIRE, LED 400W EQUIV., MO 1 480V, TYPE III, 4000K LUMINIRE, LED 100W EQUIV., IL 1 120V-277V, TYPE II, 3000K LUMINIRE, LED 100W EQUIV., IL 1 120V-277V, TYPE V, 3000K LUMINIRE, LED 250W EQUIV., IL 1 120V-277V, TYPE III, 3000K LUMINIRE, LED 250W EQUIV., IL 1 480V, TYPE III, 3000K LUMINIRE, LED 400W EQUIV., IL 1 120V-277V, TYPE III, 3000K LUMINIRE, LED 400W EQUIV., IL 1 480V, TYPE III, 3000K SWITCH, LOD RTING 1000W, MO/IL V-277V, LCK, PE SWITCH, LOD RTING 1000W, MO/IL V, YELLOW, PE ENG: ZSD REV. NO: 1 REV. DTE: 06/30/2017

20 Luminaire Components Post Top Installation ** Sheet 1 of 2,C,C COLONIL ERLY MERICN C C SPEN CONTEMPORRY Notes: 1. Stk # is no longer available from supplier 2. Stk # is to replace Stk # Stock item is available in MO only. 4. Stock item is available in IL only. 5. Position luminaire to facilitate service from the street. 6. Type III, align refractor with street side. 7. Face eye of photo electric cell north. ENG:WYW REV. NO: 3 REV. DTE: 12/21/17

21 Luminaire Components Post Top Installation ** Sheet 2 of 2 Stnd. / Stk. No. Description ** Colonial, 100W, HPS, Type III (MO) Colonial, 100W, HPS, Type V (MO) Early merican, 100W, HPS, Type III Early merican, 100W, HPS, Type V 1, Early merican, 175W, MH, Type lll 2, Early merican, 150W, PMH, Type ll Contemporary, 100W, HPS, Type III Contemporary, 100W, HPS, Type V (LL) 1 (MO) 1 ( IL) 1 ( IL) 1 (MO) 1 (MO) spen, 100W, HPS, Type III (MO) spen, 100W, HPS, Type V (MO) Switch, Photo Electric Cell C Lamp, 100W, HPS Lamp, 175W, MH Lamp, 150W, PMH 1 ENG:WYW REV. NO: 3 REV. DTE: 12/21/17

22 Luminaire Components LED Decorative (Post Top) Luminaires ** Sheet 1 of 1 MISSOURI ONLY ND NEW CONSTRUCTION ONLY 21 1/2 27 1/2 30 1/2 31 COLONIL ERLY MERICN CONTEMPORRY OR TRDITIONL SPEN LED 100W EQUIVLENT DECORTIVE (POST TOP) LUMINIRES DESCRIPTION STNDRD LED 100W EQUIVLENT ERLY MERICN, 120V 277V, TYPE III, 3000K LED 100W EQUIVLENT ERLY MERICN, 120V 277V, TYPE V, 3000K LED 100W EQUIVLENT COLONIL, 120V 277V, TYPE III, 3000K LED 100W EQUIVLENT COLONIL, 120V 277V, TYPE V, 3000K LED 100W EQUIVLENT CONTEMPO/TRDITIONL, V, TYPE III, 3000K LED 100W EQUIVLENT CONTEMPO/TRDITIONL, V, TYPE V, 3000K LED 100W EQUIVLENT SPEN, 120V 277V, TYPE III, 3000K LED 100W EQUIVLENT SPEN, 120V 277V, TYPE V, 3000K STOCK STTE DESCRIPTION NUMER (1) ERLY MERICN, LED 100W EQUIV., MO 1 120V-277V, TYPE III, 3000K ERLY MERICN, LED 100W EQUIV., MO 1 120V-277V, TYPE V, 3000K (1) COLONIL, LED 100W EQUIVLENT, MO 1 120V-277V, TYPE III, 3000K COLONIL, LED 100W EQUIVLENT, MO 1 120V-277V, TYPE V, 3000K (1) CONTEMPORRY OR TRDITIONL, LED MO 1 100W EQUIV.,120V-277V, TYPE III, 3000K CONTEMPORRY OR TRDITIONL, LED MO 1 100W EQUIV.,120V-277V, TYPE V, 3000K (1) SPEN, LED 100W EQUIVLENT, MO V, TYPE III, 3000K SPEN, LED 100W EQUIVLENT, MO V, TYPE V, 3000K (2) PHOTOCONTROL / SWITCH, LOD MO/IL RTING 1000W, 120V-277V, LCK, PE NOTES: 1. lign distribution light pattern TYPE III refractor with street side. 2. Face the eye of the photocell to the north. ENG:WYW REV. NO: 1 REV. DTE: 09/29/17

23 Luminaire Components Directional Flood ** Sheet 1 of 2 HPS Standard 250W, 120V, 6x6 Directional W, 120V, 7x6 Directional W, 480V, 6x6 Directional W, 480V, 7x6 Directional MH(1) 1000 WTT 250W, 120V, 6x6 Directional W, 120V, 6x5 Directional W, 480V, 6x5 Directional W, 120V, 7x6 Directional PMH(2) 250W, 120V, 6x6 Directional W, 120V, 6x5 Directional W, 480V, 6x5 Directional WTT IMING NGLE PROFILE ENG: WYW REV. NO: 3 REV. DTE: 01/21/10

24 Luminaire Components Directional Flood ** Sheet 2 of 2 Stnd. / Stk. No. Description ** Floodlight, HPS 250W, 120V ll Floodlight, HPS 400W, 120V ll 1 1, 4 C Floodlight, MH, 250W, 120V IL 1 1 D Floodlight, MH, 400W, 120V ll , 4 E Floodlight, PMH, 250W, multi IL 1 2 F Floodlight, PMH, 400W, 120V ll 1 3 G Floodlight,MH, 1000W, 120V (MO ONLY) H Lamp, HPS, 250W 1 I Lamp, HPS, 400W 1 1 J Lamp, MH, 250W 1 1 K Lamp, MH, 400W 1 1 L Lamp, PMH 250W 1 M Lamp, PMH 400W 1 1 N Lamp, MH, 1000W 1 O Switch, Photoeletric,120/240/277V P Floodlight, HPS 250W, 480V IL 1 1, 4 Q Floodlight, MH 400W, 480V IL 1 2, 4 R Floodlight, PMH, 400W, 480V IL 1 4 S Floodlight, HPS 400W, 480V IL 1 Notes: T Switch, Photoelectric, 480V Metal Halide Probe start (MH) Luminaires are no longer available from supplier. 2. Metal Halide Pulse start (PMH) Luminaires are to replace the obsolete MH Luminaires with equal wattage. 3. Stock No is available for new installation in MO only. 4. Stock item is available in IL only. ENG: WYW REV. NO: 3 REV. DTE: 01/21/10

25 Luminaire Components - LED Directional (Flood) Luminaires ** Sheet 1 of /2" 26 1/2" IMING FROM -30 TO +60 OFF HORIZON LED 250W EQUIVLENT DIRECTIONL (FLOOD) LUMINIRE LED 400W ND 1000W EQUIVLENT DIRECTIONL (FLOOD) LUMINIRE DESCRIPTION: MEREN MO, 4000K STNDRD LED 250W EQUIV., 120V-277V LED 250W EQUIV., 480V LED 400W EQUIV., 120V-277V LED 400W EQUIV., 480V LED 1000W EQUIV., 120V-277V DESCRIPTION: MEREN IL, 3000K STNDRD LED 250W EQUIV., 120V-277V LED 250W EQUIV., 480V LED 400W EQUIV., 120V-277V LED 400W EQUIV., 480V STOCK STTE DESCRIPTION NUMER LUMINIRE, LED 250W EQUIVLENT, MO 1 120V-277V, 6X6, 4000K LUMINIRE, LED 250W EQUIVLENT, MO 1 480V, 6X6, 4000K LUMINIRE, LED 400W EQUIVLENT, MO 1 120V-277V, 6X6, 4000K LUMINIRE, LED 400W EQUIVLENT, MO 1 480V, 6X6, 4000K LUMINIRE, LED 1000W EQUIVLENT, MO 1 120V-277V, 6X6, 4000K LUMINIRE, LED 250W EQUIVLENT, IL 1 120V-277V, 6X6, 3000K LUMINIRE, LED 250W EQUIVLENT, IL 1 480V, 6X6, 3000K LUMINIRE, LED 400W EQUIVLENT, IL 1 120V-277V, 6X6, 3000K LUMINIRE, LED 400W EQUIVLENT, IL 1 480V, 6X6, 3000K PHOTOCONTROL / SWITCH, LOD MO/IL RTING 1000W, 120V-277V, LCK, PE PHOTOCONTROL / SWITCH, LOD MO/IL RTING 1000W, 480V, YELLOW, PE ENG: ZSD REV. NO: NEW REV. DTE: 06/30/2017

26 Multiple Installation On Wood Pole ** Sheet 1 of 1 ENG: REV. NO: REV. DTE:

27 Multiple Installation On Wood Line Pole bove Communications ** Sheet 1 of MIN. J G,H 6 R. MIN. 3 4 MIN. C,D F K 16 MIN 20 MIN. 20 MIN. 12 MIN. 1 1/4 X 30 RKT. 1 1/4 X 6 RKT. 1 1/4 X 15 RKT Notes: 1. See Dist. Std for correct bracket to use. 2. Face eye of photocell north. Stnd. / Stk. No. Description ** rkt., St. Lt., 1 1/4 x rkt., St. Lt., 1 1/4 x rkt., St. Lt., 1 1/4 x C olt, Mach., 5/8 x D Washer, Square 2 1/ E Screw, Lag 1/2 x F Cable, St. Lt., Twisted (ft.) G Moulding, 1/ H Staple, 5/8 x J Staple, 3/8 x 1 3/4 C.W K Guard Cable, 1/2, Poly 1 1 L ** ** St. Lt. ssembly ENG:WYW REV. NO: 5 REV. DTE: 01/21/10

28 Multiple Installation Ornamental Concrete Pole Overhead Circuit Deadend ** Sheet 1 of 2 2 J N 23 0, 28 0 TO GROUND LINE * 500 lbs 600 lbs 500 lbs MX LODING ON POLE RCKET 28 0 Pole 33 0 Pole 6 racket REINFORCED POLE ROCK, CRUSHED 1 LIMESTONE SCREENINGS NOTE: *Not standard for new installations and replace with a fiberglass pole for maintenance if applicable. ENG:WYW REV. NO: 9 REV. DTE: 07/29/14

29 Multiple Installation Ornamental Concrete Pole Overhead Circuit Deadend ** Sheet 2 of 2 NOTES: 1. Limestone screenings to be wetted and thoroughly tamped to provide solid compaction around pole. 2. Face eye of photo electric switch north. Stnd. / Stk. No. Description ** * Pole, St. Lt., Con., 28 0 O.H./23 M.H * Pole, St. Lt., Con., 33 0 O.H./28 M.H racket, St. Lt., 2 x C Cable, St. Lt., Twisted D Clevis, Secondary 1 1 E Clamp, D.E., Wedge Type 1 1 F and, Pole, Steel, Galv. 1 1 H Rock, Crushed Limestone Screnning Lbs 850 J ** ** St. Lt. ssembly 1 1 L Guard, Cable, 1/2, Poly 2 2 M Insulator, Spool 1 N Connector, PG #6 1/0 WG Main/Tap Connector, Split, #6 WG L Main/#14 WG Cu Tap 2 2 LIMITED USE STNDRD* ENG:WYW REV. NO: 9 REV. DTE: 07/29/14

30 Multiple Installation Ornamental Concrete Pole Overhead Circuit Tangent or ngle ** Sheet 1 of 2 2 K E,H,L F POLE 33 0 POLE 18 6 RCKET C D 23 0, 28 0, or lbs 600 lbs 500 lbs MX LODING ON POLE RCKET * 2 1/2 X 8 WIRING HNDHOLE GROUND LINE TMPED ERTH OR CONCRETE SIDEWLK G 1 20 NOTE: *Not standards for new installations and replace with a fiberglass pole for maintenance if applicable. ENG:WYW REV. NO: 10 REV. DTE: 01/21/10

31 Multiple Installation Ornamental Concrete Pole Overhead Circuit Tangent or ngle ** Sheet 2 of 2 NOTES: 1. Limestone screenings to be wetted and thoroughly tamped to provide solid compaction around pole. 2. Face eye of photocontrol switch north. 3. Connect twisted pair street light cable to supply line using connector, Stock No Stnd. / Stk. No. Description ** * Pole, St. Lt., Con., 28 0 O.H./23 M.H * Pole, St. Lt., Con., 33 0 O.H./28 M.H racket, St. Lt., 2 x C Cable, St. Lt., Twisted D Guard Cable, 1/2, Poly 1 1 E Clevis, Secondary 1 1 F and, Pole, Steel, Galv. 1 1 G Rock, Crushed Limestone Screening Lbs H Wire Tie, #4 l. Poly I Insulator, Spool 1 K ** ** St. Lt. ssembly 1 1 LIMITED USE STNDRD* ENG:WYW REV. NO: 10 REV. DTE: 01/21/10

32 Multiple Installation Ornamental Concrete Pole Underground Circuit ** Sheet 1 of 2 6 RCKET 28 0 POLE 33 0 POLE , 28 0, or 35 0 * 1 NOTE: *Not standard for new installations and Replace with a fiberglass pole for maintenance if applicable. ENG:WYW REV. NO: 7 REV. DTE: 12/11/09

33 Multiple Installation Ornamental Concrete Pole Underground Circuit ** Sheet 2 of 2 NOTES: 1. Limestone screenings shall be wetted and thoroughly tamped as installed. 2. Face eye of photoelectric switch north. Stnd. / Stk. No. Description ** * Pole, St. Lt., Con., 28 0 O.H./23 M.H * Pole, St. Lt., Con., 33 0 O.H./28 M.H racket, St. Lt., 2 x C Cable, St. Lt., Twisted (ft.) D Sealer, Red Pedigree (pint) 1 1 F Connector, olted/set Screw #14 2/0, 3 Pos. 2 2 J Limestone Screenings (lb.) 850 K ** ** St. Lt. ssembly 1 1 LIMITED USE STNDRD* ENG:WYW REV. NO: 7 REV. DTE: 12/11/09

34 Fiberglass Pole 30 and 35 U.G. Circuit ** Sheet 1 of or racket 30 0 Pole (Gray) 35 0 Pole (Gray) Pole (lack) 35 0 Pole (lack) x 12 WIRING HNDHOLE SIDEWLK ENG:WYW REV. NO: 4 REV. DTE: 01/21/10

35 Fiberglass Pole 30 and 35 U.G. Circuit ** Sheet 2 of 2 Notes: 1. Face photocontrol north. 2. Limestone screenings to be wetted and thoroughly tamped to provide solid compaction around pole 3. OK to install second bracket at 180 o if required. 4. * For MO only. Stnd. / Stk. No. Description ** Pole, St. Lt., Fiberglass, 30 O.H Pole, St. Lt., Fiberglass, 35 O.H * Pole, St. Lt., Fiberglass, lack, 30 O.H * Pole, St. Lt., Fiberglass, lack, 35 O.H racket, L * racket, L. lack, C Cable, St. Lt., #10 2 Conductor Ft E Connector, olted/set Screw #14 2/0. 3 Pos F Tape, Rubber 3/ G Rock, crushed, limestone screenings H ** ** Street light assembly ENG:WYW REV. NO: 4 REV. DTE: 01/21/10

36 Fiberglass Pole 30 and 35 O.H. Circuit Tangent, ngle, or Deadend ** Sheet 1 of 2 G E,M F 1 E,M,N J 1 N C L N F J C L DEDEND DEDEND TNGENT or NGLE TNGENT or NGLE 4 x 12 WIRING HNDHOLE 3 18 GROUND LINE TMPED ERTH OR CONCRETE SIDEWLK SIDEWLK /2 x 6 CONDUCTOR ENTRNCE W / GROMMET THRU OTH SIDES ENG: WYW REV. NO: 1 REV. DTE: 07/29/14

37 Fiberglass Pole 30 and 35 O.H. Circuit Tangent, ngle, or Deadend ** Sheet 2 of 2 Notes: 1. Face photocontrol north. 2. Limestone screenings to be wetted and thoroughly tamped to provide solid compaction around pole 3. OK to install second bracket at 180 degree if required. Stnd. / Stk. No. Description ** Pole, St. Lt., Fiberglass, Pole, St. Lt., Fiberglass, racket, L C Cable, St. Lt #10 2 Conductor ft E Clevis, Secondary F and, Pole, Steel, Galv G Clamp, DE Wedge Type 1 N Connector, PG, #6 #10WG Main/Tap Connector, Split, #2 #6WG L Main/#14 WG Cu Tap L Guard, Cable, 1/2, Poly M Insulator, Spool J ** ** St. Lt. ssembly H Rock, Crushed Limestone Screening lbs O Wire Tie, #4l. Poly ENG: WYW REV. NO: 1 REV. DTE: 07/29/14

38 DIRECTIONL OUTDOOR LIGHTING On Wood Pole Directional Flood ** Sheet 1 of 1 SECONDRY OR SERVICE, IF PRESENT 12 MIN. 3 D 1 F 2 FOR MINIMUM ND PREFERRED MOUNTING HEIGHT SEE H G J,K 22 9 TYP. C I 36 Long 20 MIN. 12 MIN. DOULE LUMINIRE MOUNTING GROUND LINE COMMUNICTION, IF PRESENT SINGLE LUMINIRE MOUNTING NOTES: 1. Face photocontrol north, but multiple luminaires at the same location, adjust photocell socket to face control away from nearby light sources. 2. Connect these luminaires to a proper source. 3. Increase this dimension by 4 if open service wires extend directly out over photocell. Stnd. / Stk. No. Description ** ** Luminaire, Directional Flood 1 2 C racket, Floodlight, 18 1 F Staple 3/8 x 1 3/4 C.W. 1 1 G Moulding 1/2 1 1 H Staple 5/8 x I racket, Double Flood Mounting 1 J olt, Mach. 5/8 x 10, Galv. 1 1 K Washer, Square 2 2 L Screw, Lag 1/2 x ENG: WYW REV. NO: 9 REV. DTE: 01/21/10

39 Multiple Cable Termination Riser For Direct uried Circuit Sheet 1 of 1 F 5 G Neutral F G E NOTES: 1. If the customer furnishes the cable, it must be approved by the National Electric Code for direct burial and exposure to sunlight. The customer cable should extend to the base of the pole or to a point designated by meren. (normally 2 0 inside the customer s property line). The customer must provide enough cable to allow the connections to be made on the pole. 2. It is recommended that direct buried cable be installed in conduit under driveways and parking areas. 3. Drive the lag screw into the pole so that the schedule 80 conduit will rest on the head; thus preventing the conduit from sliding down. 4. If triplex cable is used, two fuses are required. dditional fuse sizes are available: 15 MP Stock # MP Stock # MP Stock # Install the fuse parallel to the wire so that the spring loaded indicator can flip open to show that the fuse has blown. 6. Cut the poly strap into one foot lengths. Wrap each section of the strap around the cable and secure the ends to the pole. 24 D 3 2 Stnd. / Stk. No. Description Quantity Conduit Plastic, 2 15 Ft Iron Hanger 10 Ft. C Conduit Plastic, Sch 80, 2 10 Ft. 3 D Screw Lag, 1/2 x E Strap Poly, 2 x ,5 F Fuse Secondary, 30 mp G PG* See Std Operation Code ENG:WYW REV. NO: 4 REV. DTE: 03/12/07 REFFIRMED DTE: 06/28/11

40 Post Top Installation Fiberglass Pole 14 Foot Mounting Height Sheet 1 of 1 3 E NOTES: Limestone screenings to be wetted and thoroughly tamped to provide solid compaction around the pole. 2. Generally only one tag per street light shall be installed. If more than one street light installed on the same pole, one tag per street light is required, and each tag should be installed on the same quadrant of the light. The tag should be installed visibly from the ground level but not reachable from public. See Dist. Std for more details. 3. In Missouri residential developments, the contractor will install 1 1/2 inch conduit to the pole site. meren will install the pole and the cable. 4. For fuse underground streetlight cable at pad mount transformer or pedestal, See Dist. Std **. 2 1/2 X 5 WIRING HNDHOLE F E 1 D 18 TO CENTER OF HNDHOLE 2 0 MIN. 3 0 D C 6 Stnd. / Stk. No. Description Qty. 5 1/2 12 DI Pole FG, lack, w/hand hole 1 Rock, Crushed Limestone Screening 200 C Conduit Poly 1 D Cable Duplex #6 l. E Cable, St. Lt., #10 2 conductor Ft. 17 F Connector, olt/set Screw, #4 2/0,3Pos. 2 ENG:WYW REV. NO: 8 REV. DTE: 01/21/10

41 Street Lighting Pole/Conduit Sheet 1 of 1 HND HOLE FINL GRDE C WIRE CCESS HOLE IN POLE ( REMOVE GROMMET & ENLRGE HOLE 3 0 for 17 Pole 5 0 for Pole MTERIL INSTLLED Y CONTRCTOR Stnd. / Stk. No. Description Qty Plug Conduit 1 1/ Marker uried Conduit 1 C Conduit Reducer 2 to 1 1/2 1 ENG: WYW REV. NO: 1 REV. DTE: 08/17/10

42 Street Lighting / Splice ox Installation Sheet 1 of 1 Customer cut top of conduit bend so 3 stub extends thru bottom of box. Final Grade 12 D Street Light Pole Installed by meren 24 Conduit Depth 3 C Minimum 10 1 Clean Gravel 24 Radius end NOTES: 1. Customer installs meren supplied box. Stnd. / Stk. No. Description Qty Plug Conduit, 1 1/ Marker uried Conduit 1 C Conduit Reducer 2 to 1 1/2 1 1 D Poly Splice ox 9 3/4 (W) x 14 (L) x 12 (D) 1 ENG:WYW REV. NO: NEW REV. DTE: 01/21/10

43 Installation of Underground Street Light Cable on a Wood Pole ** Sheet 1 of 2 NOTE 2 NOTE C 3 60 C 3 E 12 MIN. 24 MIN. 24 MIN. NOTE 1 D 1 1/2 Conduit Direct uried Direct uried (subject to physical damage) In Conduit In Conduit (subject to physical damage) ENG:WYW REV. NO: 6 REV. DTE: 01/21/10

44 Installation of Underground Street Light Cable on a Wood Pole ** Sheet 2 of 2 NOTES: 1. s an underground alternative, where multiple lights are being installed direct bury a T splice per Dist. Std to avoid running the cable up and down the pole. 2. Pole, bracket, and luminaire must be listed separately. 3. If pole is subject to physical damage, use schedule 80 conduit for the first 10 ft. section up to the pole. Stnd./Stk. No. Description ** Cable URD, St. Lt. #6 Duplex, l. s Req. s Req. s Req. s Conduit Plastic, 1 Sch. 40 s Req. s Req Conduit Plastic, 1 Sch. 80 s Req. s C Strap Conduit, 1 1/2 in. 2 Hole s Req. s Req. s Req. s Req. D end 1 1/2, 24 Rad. 1 1 E Reducer 1 1/2 to ENG:WYW REV. NO: 6 REV. DTE: 01/21/10

45 Multiple Installation 30 reakaway Pole Underground Circuit ** Sheet 1 of 2 MO ONLY MO ONLY MO ONLY R P D x 12 WIRING HNDHOLE REKWY JOINT 3 3 N M FIERGLSS POLE 6 RCKET RCKET GLVNIZED STEEL POLE 6 RCKET RCKET EMEDMENT DETIL CLE TERMINTION IN SE ENG: WYW REV. NO: 8 REV. DTE: 01/21/10

46 Multiple Installation 30 reakaway Pole Underground Circuit ** Sheet 2 of 2 NOTES: 1. For U.E. 120 Volt circuit use one fuse in energized line and one fuse slug (# ) in neutral. 2. Wrap plastic tie around wires where they enter bracket. 3. Screenings to be wetted and thoroughly tamped. MO ONLY MO ONLY MO ONLY Stnd. / Stk. No. Description ** Pole, Steel, Galv Pole, Fiberglass, reakaway, ase, Transf. l. 1 1 C Foundation, Steel Pile rkt., St. Lt. 2 x D rkt., St. Lt. 2 x rkt., St. Lt. Fbrgl. Mtg., rkt. St. Lt. Fbrgl. Mtg., 12 1 E Connector, Fusible F Fusetron Cart., 10 mp G Cable, St. Lt. #10 (ft.) J Rod, Ground 5/8 x K Clamp, Ground Rod 5/8, For #8 1/0 1 1 L Wire, S.D., #6.C. (ft.) M Conduit, Poly. 1 (ft.) N Rock, Crushed, Limestone,1/2, Clean (lb) P Tie, Cable 1/2 x 6 Poly. 2 2 Q Concrete Premix 90# 2 R ** ** St. Lt. ssembly ENG: WYW REV. NO: 8 REV. DTE: 01/21/10

OUTDOOR LIGHTING

OUTDOOR LIGHTING 15 00 00 01 Sheet 1 of 1 TABLE OF CONTENTS GENERAL INFORMATION HID LAMPS PHOTOCONTROLS LUMINAIRE COMPONENTS HID NEMA HEAD LUMINAIRE COMPONENTS HID HORIZONTAL LUMINAIRE COMPONENTS LED BRACKET MOUNT LUMINAIRES

More information

CONFIGURATIONS TABLE OF CONTENTS PHASE LOCATIONS (PREFERRED LOCATIONS) STRUCTURAL ELEMENTS DESIGN LIMITS

CONFIGURATIONS TABLE OF CONTENTS PHASE LOCATIONS (PREFERRED LOCATIONS) STRUCTURAL ELEMENTS DESIGN LIMITS 3 1 Sheet 1 of TLE OF CONTENTS NEUTRL LOCTIONS PHSE LOCTIONS PHSE LOCTIONS (PREFERRED LOCTIONS) STRUCTURL ELEMENTS DESIGN LIMITS NEUTRL 3 1 3 1 1 3 1 3 3 3 1 1 ** NEUTRL TP CONNECTION TO SUTRNSMISSION

More information

CABLE TERMINALS

CABLE TERMINALS 14 00 00 01 Sheet 1 of 1 TABLE OF CONTENTS LOCATION & PLACEMENT OF RISERS ON JOINT USE POLES STANDOFF BRACKET PLACEMENT AND GROUNDING ONE RISER WITH U GUARD, 2, 3, 4, & 5 SPLIT CONDUIT OR SCHEDULE 40 0

More information

METER INSTALLATIONS

METER INSTALLATIONS 25 00 00 01 TALE OF CONTENTS Sheet 1 of 2 SECTION INDEX 25 00 00 01 OUTDOOR POLE MOUNTED PRIAMRY METERING STRUCTURE 25 00 01 01 CUSTOMER OWNED UNMETERED D/D LIGHT INSTALLATION 25 01 05 00 PRIMARY METERING

More information

STREET LIGHTING ELECTRIC SERVICE (Governmental Authority) RATE SCHEDULE "SL-30''

STREET LIGHTING ELECTRIC SERVICE (Governmental Authority) RATE SCHEDULE SL-30'' 1 of 9 March 19, 2018 January 1, 2017 APPLICABILITY This rate schedule applies to electric lighting service used by any governmental authority for outdoor lighting requirements including streets, alleys,

More information

MirroStar HOLOPHANE THE MIRROSTAR LUMINAIRE COMBINES SUPERIOR PERFORMANCE WITH EASE OF MAINTENANCE TO PROVIDE A UNIQUE SOLUTION FOR AREA LIGHTING.

MirroStar HOLOPHANE THE MIRROSTAR LUMINAIRE COMBINES SUPERIOR PERFORMANCE WITH EASE OF MAINTENANCE TO PROVIDE A UNIQUE SOLUTION FOR AREA LIGHTING. OLOPNE MirroStar TE MIRROSTR LUMINIRE COMBINES SUPERIOR PERFORMNCE WIT ESE OF MINTENNCE TO PROVIDE UNIQUE SOLUTION FOR RE LIGTING. TIS COMBINTION OF PREMIUM OPTICL PERFORMNCE ND DURBLE CONSTRUCTION MKE

More information

Input Voltage: AC: VAC HC: VAC (50/60Hz) Electrical Ratings: WIDE FROSTED MODEL

Input Voltage: AC: VAC HC: VAC (50/60Hz) Electrical Ratings: WIDE FROSTED MODEL WLL MOUNT INSTLLTION E477827 E477829 PPLICTION RS luminaires are designed for use in hazardous locations, indoors, outdoors, wet location, and areas containing moisture, dirt, corrosion, vibration, and

More information

WPP25 250W MP Wal-Pak Borosilicate Glass Hinged/Removabl

WPP25 250W MP Wal-Pak Borosilicate Glass Hinged/Removabl 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 WPP25 250W MP Wal-Pak Borosilicate Glass Hinged/Removabl Catalog Number Manufacturer Description Weight per unit Product

More information

Electric underground service installation requirements

Electric underground service installation requirements MRCH 0 Electric underground service installation requirements CLL PSE S CUSTOMER CONSTRUCTION S T -888--9 OR VISIT PSE.COM/CUSTOMERCONSTRUCTION FOR MORE INFORMTION. Builder/owner/developer responsibilities

More information

Ballasts For High Intensity Discharge Lamps

Ballasts For High Intensity Discharge Lamps allasts For High Intensity Discharge Lamps Universal Means Higher Expectations In High Intensity Discharge Universal Lighting Technologies ( Universal ) offers a wide array of ballasts for High Intensity

More information

STREET LIGHTING ELECTRIC SERVICE (Governmental Authority) RATE SCHEDULE "SL-29"

STREET LIGHTING ELECTRIC SERVICE (Governmental Authority) RATE SCHEDULE SL-29 1 of 10 January 1, 2017 December 17, 2015 APPLICABILITY This rate schedule applies to electric lighting service used by any governmental authority for outdoor lighting requirements including streets, alleys,

More information

STREET LIGHTING SCHEDULE S L

STREET LIGHTING SCHEDULE S L Baltimore Gas and Electric Company Electric Retail 53 STREET LIGHTING SCHEDULE S L AVAILABILITY: For unmetered street lighting service (defined to include other public area lighting) supplied from overhead

More information

Food Processing Vaportight

Food Processing Vaportight PROJECT DTE TYPE NOTES REV: /5/08 - High Lumen Packages, up to 9,00Lm Delivered - mbient operating temps as Low as -0C(-0F) and as High as +0C(+0F) (Temps Vary by Configuration. Verify in Energy Data Section)

More information

LIGHTING CONSTRUCTION MANUAL CONTROL WIRING

LIGHTING CONSTRUCTION MANUAL CONTROL WIRING CONSTRUCTION MNUL CONTROL WIRING Back to MIN INDEX Go to SECTION INDEX TYPE DESCRIPTION PGE TYPE DESCRIPTION PGE Zellweger Streetlight Relay Bo Layout & Wiring Details 33 Streetlight Contactor Bo Layout

More information

RATE FPL UNMETERED PROTECTIVE LIGHTING

RATE FPL UNMETERED PROTECTIVE LIGHTING 1 of 9 AVAILABILITY Available to all farms, residences, churches, educational facilities, and other commercial and industrial customers for area and protective lighting served directly from existing secondary

More information

CLASSICAL ELEGANCE. COST EFFECTIVE PERFORMANCE.

CLASSICAL ELEGANCE. COST EFFECTIVE PERFORMANCE. O R N A M E N T A L L I G H T I N G K445 SOL-LUX TM ACORN LUMINAIRES CLASSICAL ELEGANCE. COST EFFECTIVE PERFORMANCE. www.kingluminaire.com CLASSICAL ELEGANCE WITH K445 Sol-Lux Luminaire The Sol-Lux luminaire

More information

Overall Dimensions. Specifications

Overall Dimensions. Specifications Overall Dimensions EFX B EFX VM Vertical Mount C 13 housing (70-400W) 19 housing (450-1000W) E D H B C D E 13.3 16.8 16.2 7.0 9.8 (33.78cm) (42.67cm) (41.15cm) (17.78cm) (24.89cm) F G H I J 22.2 11.3 6.3

More information

City of Ottawa Street Lighting. HID Shoebox Style Luminaire

City of Ottawa Street Lighting. HID Shoebox Style Luminaire TITLE: Engineering Specification RECOMMENDED: S. Edey NO: 1 REV: APPROVED: D. O Keefe. LLS0002 OF REV. DATE: 2010-01-07 9 4 City of Ottawa Street Lighting HID Shoebox Style Luminaire For City of Ottawa

More information

HID/FLOODLIGHT: NEC/CEC EXPLOSIONPROOF. Applications. Options

HID/FLOODLIGHT: NEC/CEC EXPLOSIONPROOF. Applications. Options Applications UL Listed for Outside Type (Salt Water). Ideal in Class I, Division 1 and 2 installations in refineries, in pipeline transportation facilities, at drilling rigs and in production facilities

More information

Saturn Cutoff. Order Code: Pole Order Code: Series Height Finish Options. Customer: Date: Project: Qty: Type: SAC Saturn Cutoff SAC

Saturn Cutoff. Order Code: Pole Order Code: Series Height Finish Options. Customer: Date: Project: Qty: Type: SAC Saturn Cutoff SAC Date: Customer: Project: Type: Qty: Saturn Cutoff Order Code: SAC - - - - - - - - SAC Series SAC Saturn Cutoff Pole Order Code: - - - Series Height Finish Options Optics R Type II Distribution R Type V

More information

Morris Products 53 Carey Road, Queensbury, NY 12804

Morris Products 53 Carey Road, Queensbury, NY 12804 Catalog Number 790 UPC Number 60986790 Description Low Profile Emergency Lighting allast 500 Lumen T5 & T8 Fixtures Features For both normal and emergency Flourescent lighting. In the event of a Power

More information

RATE SLM PUBLIC STREET AND HIGHWAY LIGHTING

RATE SLM PUBLIC STREET AND HIGHWAY LIGHTING 1 of 10 AVAILABILITY Available to any county or municipality in which the Company operates the local electric distribution system or to the State of Alabama for service along any highway adjacent to an

More information

KAD250MR3TBSPD04 Wall Fixture

KAD250MR3TBSPD04 Wall Fixture 8 South Street 796-76, TX Nacogdoches Phone: 96-69-79 Fax: 96-6-68 AllenWatson@elliottelectric.com MRTBSPD Wall Fixture Catalog Number MRTBSPD Manufacturer Description Area Light, Metal Halide Lamp; Lamp

More information

A2CO Series. Aktra II Cutoff Floodlight, W HID. Overall Dimensions. Specifications EPA Effective Projected Area.

A2CO Series. Aktra II Cutoff Floodlight, W HID. Overall Dimensions. Specifications EPA Effective Projected Area. Catalog Number: Approvals: - - - - - Series/Source-Wattage Optics Voltage Mounting Options Finish (Reflector) (Factory Installed) Overall Dimensions 16 (40.6 cm) 8.9 (22.5 cm) Weight (maximum) 20.5 (52.07

More information

AFL FLOODLIGHT SERIES

AFL FLOODLIGHT SERIES AFL FLOODLIGHT SERIES A FL Flood Lighting for Hazardous Locations Class I, Division 2, Groups A, B, C & D UL 844 Hazardous Locations UL 598A Marine Outside Type Zone 2, Groups IIA, IIB & IIC CUL Cast Aluminum

More information

MAGNETIC HID BALLASTS

MAGNETIC HID BALLASTS Philips dvance HID ballasts are available to operate the wide variety of metal halide, high pressure sodium and low pressure sodium lamps available in today s marketplace. Like fluorescent, HID lamps are

More information

34.00 METERING GENERAL LABELING MULTIPLE METER ENCLOSURES ON A SINGLE PREMISE

34.00 METERING GENERAL LABELING MULTIPLE METER ENCLOSURES ON A SINGLE PREMISE 4. METERING GENERAL LABELING MULTIPLE METER ENCLOSURES ON A SINGLE PREMISE 4.-4 4. SELF-CONTAINED METERING, SINGE-PHASE INSTALLATION DETAILS /4 VOLT SINGLE-PHASE UNDERGROUND RESIDENTIAL SERVICE AND METER

More information

LIGHTING CONSTRUCTION MANUAL POLE BRACKETS MINOR ROAD

LIGHTING CONSTRUCTION MANUAL POLE BRACKETS MINOR ROAD CONSTRUCTION MNUL POLE BRCKETS MINOR ROD Back to MIN INDEX Go to SECTION INDEX WOOD POLE BRCKETS CONSTRUCTION TYPE Type shown within dashed box appears on relevant construction detail drawings in this

More information

LIGHTING: EXPLOSIONPROOF FLOODLIGHT. Applications. Options

LIGHTING: EXPLOSIONPROOF FLOODLIGHT. Applications. Options Code Master 2 HID Factory Sealed Floodlights NEC: Class 1, Division 1 and 2, Groups C, D Marine Type Electric Fixtures Outside Type (Salt Water) CEC: V Class I, Division 1 and 2, Groups B, C, D Class II,

More information

HOLOPHANE Outdoor Lighting

HOLOPHANE Outdoor Lighting 68 Sign Lighting Signs have two purposesto attract attention and to convey a message. And during nighttime hours, sign lighting must provide visibility and legibility to deliver the appropriate message.

More information

CONSTRUCTION SPECIFICATION FOR THE INSTALLATION OF ROADWAY LUMINAIRES

CONSTRUCTION SPECIFICATION FOR THE INSTALLATION OF ROADWAY LUMINAIRES ONTARIO PROVINCIAL STANDARD SPECIFICATION METRIC OPSS 617 SEPTEMBER 1984 CONSTRUCTION SPECIFICATION FOR THE INSTALLATION OF ROADWAY LUMINAIRES 617.01 SCOPE 617.02 REFERENCES 617.05 MATERIALS TABLE OF CONTENTS

More information

G1-24. Applications UL listed for marine type electric fixtures--outside. Ideal in Class I, Div. 1 and 2 installations

G1-24. Applications UL listed for marine type electric fixtures--outside. Ideal in Class I, Div. 1 and 2 installations 1-24 Applications UL listed for marine type electric fixtures--outside type (salt water). Ideal in Class I, Div. 1 and 2 installations in refineries, pipeline transportation facilities; at drilling rigs

More information

THE CONNECTICUT LIGHT AND POWER COMPANY, DBA EVERSOURCE ENERGY. STREET AND SECURITY LIGHTING RATE 116 Page 1 of 9

THE CONNECTICUT LIGHT AND POWER COMPANY, DBA EVERSOURCE ENERGY. STREET AND SECURITY LIGHTING RATE 116 Page 1 of 9 Page 1 of 9 AVAILABLE for street, highway, off-street and security lighting for dusk to dawn or midnight lighting services as provided below. Excludes service off the public highway except where the fixture

More information

OUTDOOR LIGHTING ELECTRIC SERVICE RATE SCHEDULE "OL-25''

OUTDOOR LIGHTING ELECTRIC SERVICE RATE SCHEDULE OL-25'' 1 of 7 March 19, 2018 January 1, 2017 APPLICABILITY This rate schedule applies to electric lighting service used by one customer for outdoor lighting, or used by one customer, other than a governmental

More information

220/230/240V Watt High Pressure Sodium - Hazardous Location Lighting - C1D2 - Pole Mount

220/230/240V Watt High Pressure Sodium - Hazardous Location Lighting - C1D2 - Pole Mount 220/230/240V Watt High Pressure Sodium - Hazardous Location Lighting - C1D2 - Pole Mount Part #: HAL-PRM-250W-HPS-220V-PT Page: 1 Made in the USA The efficient HAL-PRM-250W-HPS-220V-PT high pressure sodium

More information

WELLGLASS EV.. Series - H.I.D. well glass lighting fixture. Aluminium with low content of copper. O-ring made of Nitrile Rubber (NBR)

WELLGLASS EV.. Series - H.I.D. well glass lighting fixture. Aluminium with low content of copper. O-ring made of Nitrile Rubber (NBR) WELLGLASS EV.. Series - H.I.D. well glass lighting fixture EV.. series well glass lighting fixtures are suitable for hazardous areas of industrial plants for lighting of indoor and outdoor structures,

More information

OUTDOOR LIGHTING ELECTRIC SERVICE RATE SCHEDULE "OL-26''

OUTDOOR LIGHTING ELECTRIC SERVICE RATE SCHEDULE OL-26'' 1 of 7 August 20, 2018 March 19, 2018 APPLICABILITY This rate schedule applies to electric lighting service used by one customer for outdoor lighting, or used by one customer, other than a governmental

More information

KANSAS CITY POWER AND LIGHT COMPANY P.S.C. MO. No. 7 Eleventh Revised Sheet No. 35 Canceling P.S.C. MO. No. 7 Tenth Revised Sheet No.

KANSAS CITY POWER AND LIGHT COMPANY P.S.C. MO. No. 7 Eleventh Revised Sheet No. 35 Canceling P.S.C. MO. No. 7 Tenth Revised Sheet No. P.S.C. MO. No. 7 Eleventh Revised Sheet No. 35 Canceling P.S.C. MO. No. 7 Tenth Revised Sheet No. 35 AVAILABILITY Available for overhead lighting of roadways through a Company-owned Street Lighting system

More information

WILDLIFE PROTECTION

WILDLIFE PROTECTION 05 00 00 01 TABLE OF CONTENTS GENERAL INFORMATION INSTALLATION OF CRITTER LINE GUARDS INSTALLATION OF TANK MOUNTED LIGHTNING ARRESTER BRACKET GUARDS 25KV & BELOW EXISTING STRUCTURE MODIFICATION 05 00 00

More information

Indianapolis Power & Light Company I.U.R.C. No. E-18 Original No. 90 One Monument Circle Indianapolis, Indiana

Indianapolis Power & Light Company I.U.R.C. No. E-18 Original No. 90 One Monument Circle Indianapolis, Indiana Indianapolis Power & Light Company I.U.R.C. No. E-18 Original No. 90 RATE MU-1 (VINTAGE) MUNICIPAL LIGHTING AND OTHER DEVICES APPLICABILITY: For Street and Traffic Lighting of public streets, parkways,

More information

APPENDIX B: LISTS OF APPROVED MATERIALS

APPENDIX B: LISTS OF APPROVED MATERIALS APPENDIX B: LISTS OF APPROVED MATERIALS APPENDIX B: LISTS OF APPROVED MATERIALS B1 Street Lighting MAY 2016 APPENDIX B1 STREETLIGHTING MATERIAL LIST 1.0 LIGHTING 1.1 Electrical Handholes CSA Precast concrete

More information

IMPACT FLOODLIGHT Architectural Flood Luminaire

IMPACT FLOODLIGHT Architectural Flood Luminaire IMPCT FLOODLIGHT rchitectural Flood Luminaire CLSSIC FORM + C O N T E M P O R R Y F E T U R E S ppealing round-back form combined with innovative design features make the Impact Flood series a best in

More information

PGL350P W PS Wallpack

PGL350P W PS Wallpack 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 PGL350P1281 350W PS Wallpack Hubbell Lighting, Inc. Catalog Number Manufacturer Description Weight per unit Product Category

More information

SHEET 1 OF 6

SHEET 1 OF 6 REVISIONS REV DESCRIPTION CHG.NO. PP'D DTE SENSOR WELD NECK MOUNTING FLNGE & WELD FTG. (FCTORY WELDED) VILBLE IN SME B16.5 RF & RTJ, ND EN 1092-1 RF. REFER TO TBLE 1 ON SHEET 2 OR FOR S ND DIMENSIONS NEW

More information

71A D 400W 277V MH Ballast

71A D 400W 277V MH Ballast 3804 South Street 75964-7263, TX acogdoches Phone: 936-569-7941 Fax: 936-560-4685 716031500 400W 277V MH allast Philips dvance Catalog umber 716031500 Manufacturer Philips dvance escription allast, Contents

More information

ORDERING INFORMATION: 120 Volts (120) 208 Volts (208) 240 Volts (240) 277 Volts (277) 480 Volts (480)

ORDERING INFORMATION: 120 Volts (120) 208 Volts (208) 240 Volts (240) 277 Volts (277) 480 Volts (480) Del Mar Corrosion resistant, Weather Tight Unit fabricated from spun Aluminum.080 Thick, Full Gasket Keeps out insects and Water. Lens & Removable Door Assembly: Hinged Door Assembly Formed from One Piece

More information

OP2 CosmoPolis Series

OP2 CosmoPolis Series Catalog Number: Approvals: - - - - - Series/Source-Wattage Optics E ballast Voltage Mounting Options Finish (Factory Installed) Accessories (Field Installed) Date: Page of 6 Overall Dimensions OP2 arm

More information

D9-3. No. WIRING DIAGRAM CONNECTIONS FOR UNDERGROUND SELF CONTAINED METERS JRH JED krich95 LINE LINE ABCN SOURCE SOURCE GROUND GROUND STUD STUD SOURCE

D9-3. No. WIRING DIAGRAM CONNECTIONS FOR UNDERGROUND SELF CONTAINED METERS JRH JED krich95 LINE LINE ABCN SOURCE SOURCE GROUND GROUND STUD STUD SOURCE SOURCE 20V 240V STUD (PER NEC) A customer supplied and installed teaser wire is required from the neutral lug to a 5th terminal mounted on the left side of the meter block between the line and load terminals.

More information

Indianapolis Power & Light Company I.U.R.C. No. E-17 Original No. 90 One Monument Circle Indianapolis, Indiana

Indianapolis Power & Light Company I.U.R.C. No. E-17 Original No. 90 One Monument Circle Indianapolis, Indiana Indianapolis Power & Light Company I.U.R.C. No. E-17 Original No. 90 RATE MU-1 (VINTAGE) MUNICIPAL LIGHTING AND OTHER DEVICES APPLICABILITY: For Street and Traffic Lighting of public streets, parkways,

More information

ROADWAY LIGHTING SYSTEMS (2545)

ROADWAY LIGHTING SYSTEMS (2545) GENERAL LIGHTING MATERIAL REQUIREMENTS General material requirements must be in accordance with MnDOT 2545.2. SERVICE CABINETS 3850 Lighting service cabinets Type L1, Type L2, Type A, Type B, and Type

More information

Telephone Fax

Telephone Fax John C. Frain Director Regulatory Strategy & Revenue Policy P.O. Box 1475 Baltimore, Maryland 21203-1475 Telephone 410.470.1169 Fax 410.470.8022 www.bge.com john.frain@bge.com January 6, 2017 Via Electronic

More information

Laredo Decorative Wallpack Family

Laredo Decorative Wallpack Family Outdoor Lighting Laredo Decorative Wallpack Family NEW Selections Full Cutoff IDA Compliant Laredo Application Guide Compact LCC 6-1ft mounting height The Laredo Family meets the Strictest Lighting Codes

More information

Directional Control Valves. General Description. Features. Specifications

Directional Control Valves. General Description. Features. Specifications echnicl Informtion Generl Description directionl control vlves re high performnce, 5-chmer, direct operted, wet rmture, solenoid controlled, 3 or 4-wy vlves. hey re ville in 2 or 3-position nd conform

More information

ExceLine 1611 Clovis R. Barker Road San Marcos, TX Fax: PT#: EXSP038A0712

ExceLine 1611 Clovis R. Barker Road San Marcos, TX Fax: PT#: EXSP038A0712 Type No. Catalog No. Job. Name ILXGHB MasterColor Elite Series APPLICATIONS Applications include industrial facilities, manufacturing plants, retail applications, and gymnasiums. CONSTRUCTION The ILX MasterColor

More information

A R C H I T E C T U R A L LO W L E V E L F LO O D L I G H T S E R I E S

A R C H I T E C T U R A L LO W L E V E L F LO O D L I G H T S E R I E S T A B L E O F C O N T E N T S A R C H I T E C T U R A L LO W L E V E L F LO O D L I G H T S E R I E S LLF755 - Low Level Flood with Anti-Glare Faceplate C1.1 LLF800 - Low Level Flood with Anti-Glare Faceplate

More information

EL PASO ELECTRIC COMPANY SCHEDULE NO. 08A GOVERNMENTAL STREET LIGHTING AND SIGNAL SERVICE RATE (CITIES)

EL PASO ELECTRIC COMPANY SCHEDULE NO. 08A GOVERNMENTAL STREET LIGHTING AND SIGNAL SERVICE RATE (CITIES) APPLICABILITY This rate is available to any village, town, city, county, state of Texas and Federal facilities for street light, freeway lighting and for traffic signal lights. TERRITORY Municipal limits

More information

DO NOT DISCARD Important information for AIRPORT MAINTENANCE DEPT

DO NOT DISCARD Important information for AIRPORT MAINTENANCE DEPT IRFIELD SIGNS R Installation Instructions for Taxiway & Runway Signs Size, Size, Size 3 & Size 5 DO NOT DISCRD Important information for IRPORT MINTENNCE DEPT To install:. Locate the frangible couplings

More information

Prismalume. Enclosed HOLOPHANE

Prismalume. Enclosed HOLOPHANE HOLOPHANE Prismalume Enclosed PRISMATIC GLASS REFLECTORS WITH TEMPERED GLASS CLOSURES ENSURE A LONG LASTING, DURABLE LIGHTING LUMINAIRE. A FULL RANGE OF WATTAGES AND LAMP TYPES COUPLED WITH AN ASSORTMENT

More information

ORDERING INFORMATION: 120 Volts (120)

ORDERING INFORMATION: 120 Volts (120) Bull38 A weather tight unit fabricated from durable grade die-cast aluminum & fully sealed, gasketed glass lens. Mount: 1/2 threaded adjustable knuckle mount Porcelain medium base socket Thermoset polyester

More information

For Conduit Inspections

For Conduit Inspections Underground Conduit Standards - Table of Content 5/8/2017 Section S22 Underground Conduit Standard Index: Description: 00 Table of Content 01 General Notes 02 Definition of Terms 03 Primary Riser Conduit

More information

Guying - Insulator Dimensional Requirements ** Lightning Protection & Grounding - Grounds

Guying - Insulator Dimensional Requirements ** Lightning Protection & Grounding - Grounds Standard Description 03 12 01 ** Configurations - Single Phase, 4 to 15kV 03 12 05 ** Configurations - Two or Three Phase Tangent or Angle on Wood Crossarm, 4 to 15 kv 03 12 07 ** Configurations - Two

More information

HID/AREA: NEC/CEC EXPLOSIONPROOF. Applications. NEC/CEC Certifications and Compliances

HID/AREA: NEC/CEC EXPLOSIONPROOF. Applications. NEC/CEC Certifications and Compliances Integrally Ballasted. 50 W, 70 W, 100 W, 150 W, 250 W, 400 W HPS; 175 W, 250 W, 320 W, 350 W, 400 W PSMH; 175 W, 250 W, 400 W MH. Applications Ideal for use in chemical and petrochemical plants, such as

More information

Lighting Tables for Existing/Base Equipment 4/15/2011

Lighting Tables for Existing/Base Equipment 4/15/2011 T12 Fluorescent Lamps and Fixtures Lighting Tables for Existing/Base Equipment 4/15/2011 LENGTH WATTS LENGTH WATTS 2' F20T12 1 8000 28 5 F60T12 1 8029 100 2 8001 46 2 8030 135 3 8002 68 F60T12 HO 1 8031

More information

TOP CAP KNOCK-OUTS FOR

TOP CAP KNOCK-OUTS FOR 2 THIS COPY IS PROVIDED ON RESTRICTED SIS ND IS NOT TO E USED IN NY WY DETRIMENTL TO THE INTERESTS OF PNDUIT CORP.. VISIT OUR ON-LINE CTLOG T WWW.PNDUIT.COM FOR LIST OF CURRENT PRTS PPLICLE FOR TOP CP

More information

Eighth Revision of Sheet No I.P.U.C. No. 1 Canceling Seventh Revision of Sheet No ROCKY MOUNTAIN POWER ELECTRIC SERVICE SCHEDULE NO.

Eighth Revision of Sheet No I.P.U.C. No. 1 Canceling Seventh Revision of Sheet No ROCKY MOUNTAIN POWER ELECTRIC SERVICE SCHEDULE NO. Eighth Revision of Sheet No. 12.1 I.P.U.C. No. 1 Canceling Seventh Revision of Sheet No. 12.1 ROCKY MOUNTAIN POWER ELECTRIC SERVICE SCHEDULE NO. 12 STATE OF IDAHO Street Lighting Service Customer-Owned

More information

Areamaster 1000 Floodlights Integrally Ballasted W HID For hazardous locations.

Areamaster 1000 Floodlights Integrally Ballasted W HID For hazardous locations. A, IIB, IIC Applications Powerful, efficient weatherproof lighting for large areas such as: Pulp and paper mills Processing plants Chemical plants Oil refineries Foundries Storage areas Waste and sewage

More information

Prismpack. V Enclosed HOLOPHANE

Prismpack. V Enclosed HOLOPHANE HOLOPHANE Prismpack V Enclosed PRISMPACK ENCLOSED LUMINAIRES ARE DESIGNED FOR THE MOST STRINGENT OF HIGH BAY APPLICATIONS. THE ALUMINUM COVERED GLASS WITH THE GASKETED GLASS BOTTOM IS ESPECIALLY DESIRABLE

More information

13V399AN-DC DRAWN BY DATE CHK SCALE SIZE

13V399AN-DC DRAWN BY DATE CHK SCALE SIZE THIS COPY IS PROVIDED ON RESTRICTED SIS ND IS NOT TO E USED IN NY WY DETRIMENTL TO THE INTERESTS OF PNDUIT CORP. TOP CP 2 KNOCK-OUTS FOR PDU POWER CORD PERFORTED SINGLE HINGE SPLIT DOOR SIDE PNEL IN SOME

More information

GREGORY RD PROPERTY LINE (PPROX.) LEGEND LIGHTING CONTROL CENTER 50W METL HLIDE FLOODLIGHT GROUND MOUNTED JUNCTION BOX PROPERTY LINE (PPROX.) UNDERGROUND CONDUIT WITH CONDUCTOR, SIZE S SHOWN. 50W METL

More information

Understanding Electronic UltraMax HID Ballasts

Understanding Electronic UltraMax HID Ballasts Understanding Electronic UltraMax HID Ballasts GE offers a complete line of electronic ballasts for HID lighting systems. Electronic HID, like electronic fluorescent systems that preceded it, significantly

More information

Baltimore Gas and Electric Company Electric -- Retail 57. Billing Watts Description Rate

Baltimore Gas and Electric Company Electric -- Retail 57. Billing Watts Description Rate Baltimore Gas and Electric Company Electric -- Retail 57 PRIVATE AREA LIGHTING ELECTRIC SCHEDULE P L AVAILABILITY: For unmetered outdoor area lighting of private property. MONTHLY RATES: 1. For supply

More information

Applications. Standard Materials. Certifications and Compliances

Applications. Standard Materials. Certifications and Compliances Code Master 2 HID Factory Sealed Luminaires Class I, Division 1 and 2, Groups C, D Class I, Division 1 and 2, Groups B, C, D Applications Ideal for use in chemical and petrochemical plants, such as manufacturers

More information

INSTALLATION INSTRUCTIONS FOR PART APPLICATIONS. Toyota. Sequoia Tundra

INSTALLATION INSTRUCTIONS FOR PART APPLICATIONS. Toyota. Sequoia Tundra INSTLLTION INSTRUCTIONS FOR PRT 99-807 99-807 KIT FETURES PPLICTIONS Toyota Sequoia 00-007 Tundra 00-006 NOTE: Refer also to the instructions included with the aftermarket radio. DIN Head Unit Provision

More information

THE STATE CORPORATION COMMISSION OF KANSAS SCHEDULE 73 KANSAS CITY POWER & LIGHT COMPANY

THE STATE CORPORATION COMMISSION OF KANSAS SCHEDULE 73 KANSAS CITY POWER & LIGHT COMPANY (Name of Issuing Utility) Replacing Schedule 73 Sheet 1 shall modify the tariff as shown hereon. Sheet 1 of 7 Sheets AVAILABILITY: Schedule ML Available for street lighting service through a Company-owned

More information

STATE OF NEW JERSEY DEPARTMENT OF TRANSPORTATION TRENTON, NEW JERSEY SPECIFICATIONS FOR HIGH PRESSURE SODIUM LUMINAIRES HIGH MAST TYPE

STATE OF NEW JERSEY DEPARTMENT OF TRANSPORTATION TRENTON, NEW JERSEY SPECIFICATIONS FOR HIGH PRESSURE SODIUM LUMINAIRES HIGH MAST TYPE STATE OF NEW JERSEY DEPARTMENT OF TRANSPORTATION TRENTON, NEW JERSEY 08625 SPECIFICATIONS FOR HIGH PRESSURE SODIUM LUMINAIRES HIGH MAST TYPE N.J. Specification No. Effective Date: July 1, 2001 New Jersey

More information

EL PASO ELECTRIC COMPANY SCHEDULE NO. 08 GOVERNMENTAL STREET LIGHTING SERVICE RATE

EL PASO ELECTRIC COMPANY SCHEDULE NO. 08 GOVERNMENTAL STREET LIGHTING SERVICE RATE APPLICABILITY This rate schedule is available to any village, town, city, county, state of Texas and Federal facility for street lighting and freeway lighting service. TERRITORY Texas Service Area MONTHLY

More information

300 Watt LED Pole Top Light Fixture VAC W Metal Halide Equivalent - Slip Fit Yoke

300 Watt LED Pole Top Light Fixture VAC W Metal Halide Equivalent - Slip Fit Yoke 300 Watt LED Pole Top Light Fixture - 120-277VAC - 1000W Metal Halide Equivalent - Slip Fit Yoke Part #: GAU-PT-60X5W-ACS-1227 Page: 1 Made in the USA The GAU-PT-60X5W-ACS-1227 High Output LED Pole Top

More information

6000W Generator - Water Cooled Diesel Engine - 25' Telescoping Tower - (4) 240W LED Fixtures - 129,6

6000W Generator - Water Cooled Diesel Engine - 25' Telescoping Tower - (4) 240W LED Fixtures - 129,6 6000W Generator - Water Cooled Diesel Engine - 25' Telescoping Tower - (4) 240W LED Fixtures - 129,6 Part #: WCDE-4-4X250LTL-LED Page: 1 Made in the USA The WCDE-4-4X250LTL-LED mobile light tower from

More information

Perimaliter Wallpacks

Perimaliter Wallpacks Perimaliter Wallpacks Perimaliter III PVL3 / PGM3 Perimaliter II PGL Solutions for Perimeter/Area Lighting Perimaliter Wallpacks The Perimaliter wallpack has been the design leader in refractor wallpacks

More information

Applications. Standard Materials. Certifications and Compliances

Applications. Standard Materials. Certifications and Compliances Code Master 2 HID Factory Sealed Luminaires NEC: Class I, Division 1 and 2, Groups C, D Class II, Division 1 and 2, Groups E, F, G Marine Type Electric Fixtures Outside Type (Salt Water) Class I, Division

More information

LED DockLight. Sustainable lighting with powerful output. UL listed for wet locations. Standard 5 year warranty

LED DockLight. Sustainable lighting with powerful output. UL listed for wet locations. Standard 5 year warranty Patent # USD0587833 Sustainable lighting with powerful output Industrial luminaire with 15 watt power consumption Rated life of 50,000 hrs to 70% lumen maintenance Highly impact resistant; LED technology

More information

7. Residential Single-Family and Duplex Buildings (Dwellings)

7. Residential Single-Family and Duplex Buildings (Dwellings) Sin g le -F a mily a n d Du p le x Bu ild in g s 2016 Electric Service Requirements, 2 nd Edition Section 7 Section 7 Residential Single-Family and Duplex Buildings (Dwellings) Directory Page 7.1 General

More information

SECTION A-A

SECTION A-A 40.08 D 8 6 5 4 3 2 1 WRNING: IF THERE RE NY DISCREPNCIES ETWEEN THE CD FILE ND THE DRWING, THE DRWING WILL TKE PRECEDENCE. IF IN DOUT, SK. D C 51.1 48 20.25 18 C 23.68 15.12 NOTE: DRWER UNIT NOT INCLUDED,

More information

d/b/a EVERSOURCE ENERGY Cancels M.D.P.U. No. 44 STREET AND SECURITY LIGHTING RATE S-1

d/b/a EVERSOURCE ENERGY Cancels M.D.P.U. No. 44 STREET AND SECURITY LIGHTING RATE S-1 Page 1 of 10 AVAILABILITY Street and security lighting services are available under this rate to public authorities for street, highway, bridge, parkway and adjacent area lighting and flood lighting. Area

More information

RESOLUTION NO

RESOLUTION NO RESOLUTION NO. 28068 RESOLUTION OF THE COUNCIL OF THE CITY OF SANTA ROSA AMENDING RESOLUTION NUMBER 20741 ADOPTING REVISED STREET LIGHT DESIGN STANDARDS WHEREAS, the Council of the City of Santa Rosa,

More information

Applications. Standard Materials

Applications. Standard Materials Code Master Jr. HID Factory Sealed Luminaires Integrally Ballasted. 50 W, 70 W, 00 W, 50 W HPS; 50 W, 70 W, 00 W, 75 W PSMH. 75 W MH V. Medium Base. For Use with Threaded Metal Conduit. Class I, Division

More information

Nema Head We light your world

Nema Head We light your world Nema Head We light your world 03.15.18 THD 80 PF >.95 10kV Surge Protector + 5-40 C~50 C 35,000 Warranty YEAR LED Nema Head 44w/65w Advances in LED technology allow us to create

More information

INSTALLATION GUIDE FOR 30 GALLON SPRAY SYSTEM AERATOR

INSTALLATION GUIDE FOR 30 GALLON SPRAY SYSTEM AERATOR INSTLLTION GUIDE FOR 30 GLLON SPRY SYSTEM ERTOR ES L. T. RICH PRODUCTS TLE OF CONTENTS 1.0 IMPORTNT INFORMTION... 2 1.1 PURPOSE... 2 1.2 PRODUCT OVERVIEW... 2 1.3 MNUL OVERVIEW... 2 1.4 SFETY... 2 1.5

More information

150W Explosion Proof Telescoping Anodized Aluminum Pole Mount LED Light Tower ' -Surface Mount

150W Explosion Proof Telescoping Anodized Aluminum Pole Mount LED Light Tower ' -Surface Mount 150W Explosion Proof Telescoping Anodized Aluminum Pole Mount LED Light Tower - 5-12' -Surface Mount Part #: EPL-APM-150LED-RT Page: 1 Made in the USA The EPL-APM-150LED-RT Telescoping Pole Mounted Explosion

More information

Single Head LED Telescoping Light Tripod to 10 feet Watts - Adjustable U-Bracket

Single Head LED Telescoping Light Tripod to 10 feet Watts - Adjustable U-Bracket Single Head LED Telescoping Light Tripod - 3.5 to 10 feet - 120 Watts - Adjustable U-Bracket Part #: WALTP-P10W-1X120X2ET-1227 Page: 1 Made in the USA The Larson Electronics WALTP-P10W-1X120X2ET-1227 Tripod

More information

DESCRIPTION Galleria's beauty and versatility make it an excellent choice for roadway and general area lighting applications. An aesthetic reveal in the formed aluminum housing gives the Galleria a distinctive

More information

Pentahead bolts See note 2. Conduit run as specified. Company facility. Refer to drawing SS8.6-2 or SS8.6-3 STANDARD SERVICE INSTALLATION

Pentahead bolts See note 2. Conduit run as specified. Company facility. Refer to drawing SS8.6-2 or SS8.6-3 STANDARD SERVICE INSTALLATION PULL BOX F SECONDARY SYSTEM Typical grade Pentahead bolts See note 2 Conduit run as specified Plastic or fiberglass for grass areas or Polymer concrete for light duty areas (see notes 2, 3, & 4) Company

More information

00083FAB-DC DRAWN BY DATE CHK SCALE SIZE

00083FAB-DC DRAWN BY DATE CHK SCALE SIZE D0D/6 THIS COPY IS PROVIDED ON RESTRICTED SIS ND IS NOT TO E USED IN NY WY DETRIMENTL TO THE INTERESTS OF PNDUIT CORP. 0 5/4/8 SPLIT SIDE PNEL JGC TOP CP CURVED PERFORTED SINGLE HINGE DOOR SPLIT SIDE PNEL

More information

Lamps CERAMIC METAL HALIDE

Lamps CERAMIC METAL HALIDE s CERAMIC METAL HALIDE CERA ARC EX / Outdoor CERA ARC PRO / Indoor Long up to 24000 hrs Low maintenance s need to be changed less often, therefore saving on maintenance costs, reducing waste, and lessening

More information

Pole Series. Series Reflector Lens Mounting Lamping Finish Voltage. S w S w S w S w

Pole Series. Series Reflector Lens Mounting Lamping Finish Voltage. S w S w S w S w Type: Qty: QHO Series Reflector Lens Mounting Lamping Finish Voltage QHO Quadro HO R Type II Aluminum reflector R5 Type V Aluminum reflector L S Project: Flat Glass Sagged Glass Series Reflector Lens Mounting

More information

Lighting Tables for New Equipment 7/16/2008

Lighting Tables for New Equipment 7/16/2008 T8 and SUPER T8 Fluorescent Lamps and Fixtures with Electronic Ballasts LENGTH 2' F17T8 1 18 200 9.00 --- --- 2 32 201 9.00 --- --- 3 48 202 15.00 --- --- 4 57 203 15.00 --- --- F17T8 with Reflectors 1

More information

Understanding Electronic UltraMax HID Ballasts

Understanding Electronic UltraMax HID Ballasts Understanding Electronic UltraMax HID Ballasts GE offers a complete line of electronic ballasts for HID lighting systems. Electronic HID, like electronic fluorescent systems that preceded it, significantly

More information

Mercmaster LED Series Luminaires Enclosed and Gasketed Fixtures

Mercmaster LED Series Luminaires Enclosed and Gasketed Fixtures Mercmaster Series Luminaires LIGHTING: ENCLOSED AND GASKETED AREA /INDUCTION Applications Enclosed and gasketed fixtures suitable for use in: Marine and wet locations A wide range of industrial, chemical

More information

16 Watt White LED Strip Light for Hazardous Location Lighting - 24" Surface Mount Bar - C1D2

16 Watt White LED Strip Light for Hazardous Location Lighting - 24 Surface Mount Bar - C1D2 16 Watt White LED Strip Light for Hazardous Location Lighting - 24" Surface Mount Bar - C1D2 Part #: HAL-24-16W-LED-WHT Page: 1 Buy American Compliant The HAL-24-16W-LED-WHT from Larson Electronics is

More information

MNPV6 REV A DISCO 4X FINAL ASSY

MNPV6 REV A DISCO 4X FINAL ASSY NOTES 1) ITEM 2,USR, MUST HVE TWO END SCREWS REMOVED, SO THT ITEM, WHITE INSULTORS, CN E INSTLLED. 2) UNIT SHIPS WITH THE FOLLWING ECH LCK TWO WIRE STRIN RELIEFS, P/N 9--1 ECH LCK STRIN RELIEF NUTS, P/N

More information