SHEET 1 OF 6

Size: px
Start display at page:

Download "SHEET 1 OF 6"

Transcription

1 REVISIONS REV DESCRIPTION CHG.NO. PP'D DTE SENSOR WELD NECK MOUNTING FLNGE & WELD FTG. (FCTORY WELDED) VILBLE IN SME B16.5 RF & RTJ, ND EN RF. REFER TO TBLE 1 ON SHEET 2 OR FOR S ND DIMENSIONS NEW RELESE DSI DRV /24/09 SEE TBLE 1 SHEET 2 OR SW (PIPE) SENSOR FLNGE, TYPE ND RTING TO MTCH MOUNTING FLNGE OPPOSITE SIDE SUPPORT: SOCKETWELD FITTING SHOWN REFER TO SHEET 5 FOR PPLICBLILITY ND OTHER OPTIONS. WLL ID INSTRUMENT CONNECTIONS: SHOWN HERE: REMOTE-MOUNT FOR HORIZONTL LINE WITH 1/2" NPT/SOCKETWELD. (REFER TO SHEET 4 FOR OTHER INSTRUMENT CONNECTION OPTIONS) FLOW FLOW BI-DIRECTIONL SEE SHEETS 2 & W (PIPE) NOTES: MHS 7 ODF (1) 1. ROSEMOUNT INC. CERTIFIES THIS DRWING IS IN CCORDNCE WITH ROSEMOUNT ENGINEERING SPECIFICTIONS & CCURTELY REPRESENTS THE EQUIPMENT FURNISHED. 2. LL ORIENTIONS SHOWN FOR REFERENCE ONLY. FOR CTUL RECOMMENDED LOCTION & ORIENTTION OF SENSORS & INSTRUMENT CONNECTIONS REFER TO INSTLLTION INSTRUCTION MNUL &/OR QUICK INSTLLTION GUIDE (QIG) FIELD WELD. REFER TO INSTLLTION INSTRUCTIONS FOR WELD REQUIREMENTS. 4. MXIMUM PRESSURE: NSI CLSS 2500 (NOT VILBLE WITH LL MTERILS ND OPTIONS) CONSULT PRODUCT DT SHEET FOR DDITIONL INFORMTION. 5. MXIMUM TEMPERTURE: 1200 F (NOT VILBLE WITH LL MTERILS ND OPTIONS) CONSULT PRODUCT DT SHEET FOR DDITIONL INFORMTION. 6. FOR MODEL SELECTIONS, REFER TO ROSEMOUNT PRODUCT DT SHEETS. 7 NNUBR PRIMRY FLOW ELEMENT IS CCURTE ONLY WITH CORRECT D, DRILLED, MOUNTING HOLE. NO TORCH CUT LLOWED. SEE TBLE NO.2 / SHEET 2 FOR 'MHS' DIMENSIONS. 8. SEE SHEETS 2 & TBLES 1 & 2 FOR LL 'NMED' DIMENSIONS. NOTE: UNLESS OTHERWISE SPECIFIED LL INFORMTION IS BOTH (TYP) & GENERL TO STNDRD PRODUCT DESIGN LL PIPE SECTIONS SHOWN FOR REFERENCE ONLY *UNLESS OTHERWISE SPECIFIED DIMENSIONS IN INCHES (MM) *LL DIMENSIONS RE NOMINL ND RE FOR REFERENCE ONLY DR. J.PYLOR 2/4/09 DRWING TGGING SPECILS TYPE I PPROVL M.VINELL /24/ FOR HORIZONTL LINES WITH REMOTE-MOUNT INSTRUMENT CONNECTIONS TITLE C DIMENSIONL DRWING, MODEL 585,FLNGED W/OPPOSITE SIDE SUPPORT SCLE: NONE SHEET 1 OF 6

2 SENSOR 11 FLNGE TYPE NSI RF NSI RTJ DIN RF PRESSURE CLSS 00# MOUNTING 1-1/2" S # 1-1/2" XXH 00# 1-1/2" S # 1-1/2" XXH PN16 PN40 PN /2" S80 ODF (1 &/OR 2).88 (98.6) 4.1 (104.9) 4.44 (112.8) 4.94 (125.5) 6.76 (171.7) 6 (10.1) 4.1 (109.5) 4.44 (112.8) 4.94 (125.5) 6.81 (17.0).21 (81.5).88 (98.6) TBLE 1: DIMENSIONL INFORMTION SENSOR (17.5).81 (20.6) (8.1) 2.00 (50.8).88 (22.4) 1.00 (25.4) (8.1) 2.06 (52.).71 (18.0) 1.02 (26.0) (REMOTE- 9.7 (246.4) 10.1 (256.5) 11.6 (294.6) 1.9 (5.1) 10.1 (256.5) 10.5 (266.7) 11.6 (294.6) 1 (55.6) 9.1 (21.1) 10.0 (25) (DIRECT (25) 11.0 (279.4) 10.8 (274.) 11.0 (279.4) 9.4 (28.8) 10. (261.6) (FLNGED (WELDED (NPT (OF FTG.S) 5.6 (142) (127) 5.9 (150) (74).1 (79) 1" 000# (155) (168) 7.0 (178) /2" 8.0 (257) (91) XXH (20).1 (79) (127) 6. (160) " 6.6 (74) (79) 000# (155) (168) 7.0 (178) /2" 8.0 (262) (91) XXH (20) (125) " (150) 5.9 (74) (79) 000# 6.7 (150) (170) SENSOR TBLE 2: SENSOR PROPERTIES SW SENSOR WIDTH MHS ( MOUNTING HOLE) W (WIDTH CCROSS INSTRUMENT CONNECTION) (20) 7/8" (22).8 (97) (0) 1-5/16" (4) 4.1 (104) (58) 2-1/2" (64) 5. (15) SENSOR 22 FLNGE TYPE NSI RF NSI RTJ DIN RF PRESSURE CLSS 00# MOUNTING 2" S # " XXH 00# 2" S # " XXH PN16 PN40 PN100 2" S80 ODF (1 &/OR 2) 4.12 (104.6) 4.8 (111.) 4.75 (120.7) 5.88 (149.4) 9.88 (251.0) 4.1 (109.5) 4.62 (117.) 4.81 (122.2) 5.94 (150.9) (25).40 (86.4).51 (89.2) (109.2) TBLE 1: DIMENSIONL INFORMTION SENSOR (19.1).88 (22.4) 1.25 (1.8) 1.75 (44.5) 2.88 (7.2).94 (2.9) (.) 1.81 (46.0).00 (76.2).71 (18.0).79 (20.1) 1.10 (27.9) (REMOTE (25) 11.1 (281.9) 12.8 (25.1) 17.9 (454.7) 11.0 (279.4) (2) 18.1 (459.7) 9.2 (2.7) 9.4 (28.8) 10.5 (266.7) (DIRECT- 10. (261.6) 11.4 (289.6) (FLNGED (WELDED (NPT (OF FTG.S) (147) (152) (155) /2" (102) (114) 000# (165) (175) 8.8 (224) 8.5 (216) " XXH (6) (104) (05) (152) 11. (170) /2" (102) (114) 000# (165) (294.6) (180) 9.5 (241.) 9.7 (246.4) 10.8 (274.) 8.9 (226) 14.5 (68) (127) 5.2 (12) 6. (160) 4.1 (104) (102) 4.5 (114) 2" XXH 1-1/2" 000# 8.5 (216) 12.0 (05) 6.5 (165) SHEET: 2 of 6

3 SENSOR 44 FLNGE TYPE NSI RF NSI RTJ DIN RF PRESSURE CLSS 00# 900# 1500# 2500# 00# 900# 1500# 2500# PN16 PN40 PN100 MOUNTING " S40 " S40 " S40 ODF (1 &/OR 2) 4.62 (117.4) 0 (127.0) 5.8 (16.7) 8.19 (208.0) 8.56 (217.4) (284.2) 4.81 (122.2) 5.25 (1.4) 5.44 (18.2) 8.25 (209.6) 8.6 (219.2) 11.8 (289.1).84 (97.5) 4.16 (105.7) 4.95 (125.7) TBLE 1: DIMENSIONL INFORMTION SENSOR (2.9) (8.1) 2.00 (50.8) 2.8 (60.5).25 (82.6) (5.1) 1.56 (9.6) 2.06 (52.2) 2.44 (62.0).44 (87.4).79 (20.0).95 (2) 1.26 (2.0) (REMOTE (04.8) 15. (88.6) 1 (408.9) 19.6 (497.8) 11.2 (284.5) 11.8 (299.7) 12.2 (09.9) 15.5 (9.7) 16.2 (411.5) 20.0 (508.0) 9.8 (248.9) 10.2 (259.1) 11. (DIRECT- 1.7 (48.0) 14. (6.2) 1 (81.0) 14.2 (60.7) 14.8 (75.9) 15.2 (8) 12.8 (25.1) 1.2 (5.) 14. (6.2) (FLNGED 6.6 (168) 7.1 (WELDED (NPT (OF FTG.S) 7.5 (191) (180).9 8. " S (99) (211) (201) (295) (292) (15) 6.4 (12) 16.2 (16) 1 (412) (56) (178) (191) 8..9 (211) " S (99) 8. (206) (211) (297) (292) (20) 6.4 (12) 16.6 (16) 1 (422) (56) 5.6 (142) (201) " S80 (155) (99) (18) (21) PIPE XIS FLOW HIGH PRESSURE LOW PRESSURE HIGH PRESSURE LOW PRESSURE PIPE XIS FLOW REMOTE-MOUNT HED FOR HORIZONTL LINES REMOTE-MOUNT HED FOR VERTICL LINES SHEET: of 6

4 7/16 X 2-1/4" LG BOLTS SUPPLIED S STNDRD 8.0 (20).8 (95) DIRECT-MOUNT HED WITH -VLVE OR 5-VLVE MNIFOLD (-VLVE MNIFOLD SHOWN) (CONFIGURTION IDENTICL FOR HORIZONTL ND VERTICL LINES) (VILBLE FOR PRESSURE RTINGS UP TO NSI 600/DIN PN100 ONLY) 12. (12) 6.2 (157) 7/16 X 2-1/4" BOLTS SUPPLIED S STNDRD (128) BI-DIRECTIONL/REDUNDNT DIRECT-MOUNT HED WITHDUL -VLVE MNIFOLD (CONFIGURTION IDENTICL FOR HORIZONTL ND VERTICL LINES) (VILBLE FOR PRESSURE RTINGS UP TO NSI 600/DIN PN100 ONLY) SHEET: 4 of 6

5 ODF (2) FLNGED OPPOSITE SIDE SUPPORT OPTION (FLNGE, RTING & ODF DIMENSION MTCHES THT OF TOPSIDE MOUNTING) WELD CP THREDED/SOCKET WELD SUPPORT PLUG (SOCKET WELD SHOWN) 000# THREDED/SOCKET WELD BRNCH FITTING BUTTWELD BRNCH FITTING WELDED OPPOSITE SUPPORT DETIL (PPLICBLE TO LL SENSOR 44) (PPLICBLE TO SENSOR 11 ND 22 WITH 2500# RTING) THREDED/SOCKET WELD OPPOSITE SUPPORT DETIL (PPLICBLE TO LL SENSOR 11 & 22 IN PRESSURE CLSS 1500# & UNDER) (NOTE: SOCKET WELD VERSION SHOWN) SHEET: 5 of 6

6 .1 ( 78.1) 2.6 (6) NNUBR (SHOWN FOR REFERENCE ONLY) 14 (5) B ROSEMOUNT MODEL 78 RTD W/THERMOWELL & CONNECTION HED 1/2" NPT CONDUIT CONNECTION 12.2 (10) /4" 000# SOCKETWELD FITTING (INCLUDED - MTERIL MTCHES MOUNTING MTERIL).6 (16).82 MIN ( 20.8 MIN.) DRILL THRU ONE WLL ONLY FOR TEMP SENSOR (102).75 ( 19) 4 x ID SEPRTION (MINIMUM) TEMP SENSOR DOWNSTREM OF NNUBR B FLOW REMOTE TEMPERTURE SENSOR (VILBLE FOR UP TO 1500# PRESSURE RTING) SHEET: 6 of 6

VB-7000 Series. Selection Guide. Applications. Applicable Literature. Selection Guide Contents

VB-7000 Series. Selection Guide. Applications. Applicable Literature. Selection Guide Contents V-7000 Series Selection Guide T V-7000 Series 1/2 to 2 Globe Vlves with Fort M400, M800, nd M1500 ctutors pplictions T Fort M400, M800, nd M1500 series liner ctutors mount directly 1 onto 1/2 to 2 V-7xxx

More information

GATE VALVES ALV-1 FORGED STEEL NOMINAL PRESSURE NOMINAL SIZE MATERIALS CONNECTIONS. ANSI Class PN /4-2 DN 8-50.

GATE VALVES ALV-1 FORGED STEEL NOMINAL PRESSURE NOMINAL SIZE MATERIALS CONNECTIONS. ANSI Class PN /4-2 DN 8-50. FORGED STEEL GTE VLVES LV-1 NOMINL PRESSURE NSI Class 150-1500 PN 16-250 NOMINL 1/4-2 DN 8-50 MTERILS Carbon Steel Low lloy Steel Stainless Steel CONNECTIONS Socket Weld Butt Weld Threaded Flanged XELVLVES

More information

Series 250 Type and Type Pneumatic Control Valves Type 3251 Globe Valve

Series 250 Type and Type Pneumatic Control Valves Type 3251 Globe Valve Series 250 Type 3251-1 nd Type 3251-7 Pneumtic Control Vlves Type 3251 Globe Vlve DIN version Appliction Control vlve for process engineering pplictions with high industril requirements Nominl size DN

More information

4/2- and 4/3-way shut-off valve

4/2- and 4/3-way shut-off valve Courtesy of CMA/Flodyne/Hydrdyne Motion Control Hydrulic Pneumtic Electricl Mechnicl (00) 426-540 www.cmfh.com 4/2- nd 4/3-wy shut-off vlve Type Z4WE Size 6 Component series 3X Mximum operting pressure

More information

13V399AN-DC DRAWN BY DATE CHK SCALE SIZE

13V399AN-DC DRAWN BY DATE CHK SCALE SIZE THIS COPY IS PROVIDED ON RESTRICTED SIS ND IS NOT TO E USED IN NY WY DETRIMENTL TO THE INTERESTS OF PNDUIT CORP. TOP CP 2 KNOCK-OUTS FOR PDU POWER CORD PERFORTED SINGLE HINGE SPLIT DOOR SIDE PNEL IN SOME

More information

BIMETAL-POINTER-THERMOMETER

BIMETAL-POINTER-THERMOMETER BIMETA-POINTER-THERMOMETER Chemicl version cc. EN 30 byonet cse IP 6 With or without filling Suitble for chemicl nd petrochemicl industry, food, pulp nd pper industry nd for mchine nd pprtus contruction.

More information

Molded Interior Door Cambridge. Product Detail Sheets Table of Contents

Molded Interior Door Cambridge. Product Detail Sheets Table of Contents Page 1 Molded Interior Door Cambridge Product Detail Sheets Table of Contents Construction Details... 3 6-8 Standard Doors 2-Panel 1-0 thru 1-8...pg. 4 2-Panel 1-10 thru 3-0...pg. 5 6-8 Bi-Fold Doors 2-Panel

More information

TOP CAP KNOCK-OUTS FOR

TOP CAP KNOCK-OUTS FOR 2 THIS COPY IS PROVIDED ON RESTRICTED SIS ND IS NOT TO E USED IN NY WY DETRIMENTL TO THE INTERESTS OF PNDUIT CORP.. VISIT OUR ON-LINE CTLOG T WWW.PNDUIT.COM FOR LIST OF CURRENT PRTS PPLICLE FOR TOP CP

More information

PREFILL AND EXHAUST VALVE PV 100 TO PV 200

PREFILL AND EXHAUST VALVE PV 100 TO PV 200 PREFILL ND EHUST VLVE Ref. No. Relese 08/2006 1 Description Set type construction. llows free flow from it's port to port. Flow from port to port cn e hd y pplying pilot pressure to it's port. The decompression

More information

Installation Instruction

Installation Instruction CIVCON MNIFOLD INSTLLTION MNUL REVISION 5/9/05 PETROLEUM MNIFOLD for TNK TRUCKS Installation Instruction Unit of Knappco, Inc. Phone: 86-74-6600 Fax: 86-74-06 CIVCON MNIFOLD INSTLLTION MNUL REVISION 5/9/05

More information

DIEBOLD 3750 CASH RECYCLER TERMINAL. 13mm ( 2") UL SAFE - 15" OR 19" DISPLAY THROUGH THE WALL 330mm (13") PLAN VIEW FRONT ELEVATION SECTION

DIEBOLD 3750 CASH RECYCLER TERMINAL. 13mm ( 2) UL SAFE - 15 OR 19 DISPLAY THROUGH THE WALL 330mm (13) PLAN VIEW FRONT ELEVATION SECTION L8 CLL -800--600 R DIEBOLD 0 CSH RECYCLER TERMINL mm ( ") UL SFE - " OR " DISPLY THROUGH THE WLL 0mm (") 64 SFE ( 6 ") CONSULT WITH DIEBOLD INSTLLTION/SERVICE BRNCH FOR DDITIONL DETILS ND INFORMTION. PLESE

More information

1 SGI 500XT INVERTER TRANSFORMER WITH OUTDOOR ENCLOSURE CONDUIT, FITTINGS AND CONDUCTORS AS REQUIRED

1 SGI 500XT INVERTER TRANSFORMER WITH OUTDOOR ENCLOSURE CONDUIT, FITTINGS AND CONDUCTORS AS REQUIRED 1. THIS DOCUMENT IS INTENDED TO ILLUSTRTE THE PPLICTION OF 600VC TRNSFORMER WITH OUTDOOR ENCLOSURE WITH SOLECTRI RENEWLES SGI 500XT INVERTER. EXMPLES OF THE FOLLOWING RE GIVEN: - INVERTER TO TRNSFORMER

More information

BERMAD Waterworks. 400 Series. Basic Valve. ??????? WW-400 Basic Valve

BERMAD Waterworks. 400 Series. Basic Valve. ??????? WW-400 Basic Valve Bsic Vlve??????? WW-400 Bsic Vlve The bsic Model WW-400 diphrgm ctuted hydruliclly operted vlve is t the leding edge of control vlve design. It combines simple nd relible construction with superior performnce,

More information

2/2 4/4 Solenoid Directional Seat Valve, ISO Size 03

2/2 4/4 Solenoid Directional Seat Valve, ISO Size 03 2/2 4/4 Solenoid Directionl Set Vlve, ISO Size 03 Q mx = 20 l/min, p mx = 315 r idirectionl set-vlve shut-off, direct cting, electriclly operted 1 Description he W2N / W2 series of 2/2 4/4 solenoid operted

More information

2/2 Solenoid Operated Seat Valve, ISO Size 03

2/2 Solenoid Operated Seat Valve, ISO Size 03 2/2 Solenoid Operted Set Vlve, ISO Size 03 Q mx = 40 l/min (11 gpm), p mx = 315 r (4500 psi) Sndwich design, idirectionl lek-proof shutoff, direct cting, electriclly operted 1 Description 2 echnicl dt

More information

330mm (13") MAXIMUM WALL THICKNESS IN AREA OF UNIT. 330mm (13") MAXIMUM WALL THICKNESS IN AREA OF UNIT TYPICAL ACCESS TO LEVELING 15

330mm (13) MAXIMUM WALL THICKNESS IN AREA OF UNIT. 330mm (13) MAXIMUM WALL THICKNESS IN AREA OF UNIT TYPICAL ACCESS TO LEVELING 15 L CLL -800--600 R DIEBOLD 0 CSH DISPENSER THROUGH 0mm (") MXIMUM WLL 0mm ( 6" ) CEN I, CEN III GS, or CEN IV GS SFES CONSULT WITH DIEBOLD INSTLLTION/SERVICE BRNCH FOR DDITIONL DETILS ND INFORMTION. PLESE

More information

CS 7750 FULL FUNCTION TERMINAL 15" OR 19" DISPLAY - THROUGH THE WALL 330mm (13")

CS 7750 FULL FUNCTION TERMINAL 15 OR 19 DISPLAY - THROUGH THE WALL 330mm (13) L08 CLL -800--600 " OR " DISPLY - THROUGH THE WLL 0mm (") 40mm ( 6") CEN I CONSULT WITH DIEBOLD NIXDORF INSTLLTION/SERVICE BRNCH FOR DDITIONL DETILS ND INFORMTION. PLESE SEE PLNNING ND SITE PREPRTION GUIDE

More information

STANDARD AND FULL HEIGHT - REAR LOAD - WITH 40mm (1 16") CEN I, CEN III GAS or CEN IV GAS SAFES

STANDARD AND FULL HEIGHT - REAR LOAD - WITH 40mm (1 16) CEN I, CEN III GAS or CEN IV GAS SAFES L STNDRD ND FULL HEIGHT - RER LOD - WITH 0mm ( 6") "LL DIMENSIONS ND DESIGN CRITERI PGE OF 8 FRONT - STNDRD HEIGHT SEE PGES and FOR CS 00 STNDRD HEIGHT DETILS FRONT - FULL HEIGHT SEE PGES and FOR CS 00

More information

Section 6. Transformers. Table of Contents. General Purpose, Dry Type, 600 Volts and Below. Industrial Control. Instrument, 600 Volt Class

Section 6. Transformers. Table of Contents. General Purpose, Dry Type, 600 Volts and Below. Industrial Control. Instrument, 600 Volt Class Tble of ontents Section Trnsformers Generl Purpose, Dry Type, 00 Volts nd elow Three-Phse, Energy Efficient Trnsformers -2 Single-Phse, Energy Efficient Trnsformers -2 K-Rted Trnsformers -3 Drive Isoltion

More information

2/2 Solenoid Operated Seat Valve, ISO Size 03

2/2 Solenoid Operated Seat Valve, ISO Size 03 2/2 Solenoid Operted Set Vlve, ISO Size 03 Q mx = 20 l/min (5.3 gpm), p mx = 315 r (4500 psi) Sndwich design, idirectionl lek-proof shutoff, direct cting, with EX-sfty sol. coil Vlve: With crtridge vlve,

More information

3/3, 4/2 and 4/3 directional poppet valve with solenoid actuation

3/3, 4/2 and 4/3 directional poppet valve with solenoid actuation 3/3, 4/2 nd 4/3 directionl poppet vlve with solenoid ctution RE 22035/06.10 Replces: 12.08 1/16 Type SEC Size 6 Component series 1X Mximum operting pressure 420 r [6100 psi] Mximum flow 25 l/min [6.6 US

More information

CV3000 Series Smart-Port Single Seated Control Valves with Steam Jacket Model HLS

CV3000 Series Smart-Port Single Seated Control Valves with Steam Jacket Model HLS No. SS2-8113-0220 CV3000 Series Smrt-Port Single Seted Control Vlves with Stem Jcket Model HLS OVERVIEW Model HLS Smll-Port Single Seted Control Vlves with Stem Jcket re designed for hevy duty service

More information

Y03002/ Prefill Exhaust Valve. Description

Y03002/ Prefill Exhaust Valve. Description Prefill Exhust Vlve 350 r /6 Description The Prefill Exhust Vlve (PV) is hydrulic-pilot operted check vlve with set type construction. It llows free flow from port A to port B. Flow from port B to port

More information

00083FAB-DC DRAWN BY DATE CHK SCALE SIZE

00083FAB-DC DRAWN BY DATE CHK SCALE SIZE D0D/6 THIS COPY IS PROVIDED ON RESTRICTED SIS ND IS NOT TO E USED IN NY WY DETRIMENTL TO THE INTERESTS OF PNDUIT CORP. 0 5/4/8 SPLIT SIDE PNEL JGC TOP CP CURVED PERFORTED SINGLE HINGE DOOR SPLIT SIDE PNEL

More information

Transmission and Driveline. Section 2A - Transmission and Driveline

Transmission and Driveline. Section 2A - Transmission and Driveline Trnsmission nd Driveline Trnsmission nd Driveline Tle of Contents Section 2A - Trnsmission nd Driveline 2 A Generl Informtion...2A-2 Ger Rtio Selection...2A-2 Engine nd Propeller Shft Instlltion Angle...2A-2

More information

DIEBOLD 5550 CASH DISPENSER THROUGH 330mm (13") MAXIMUM WALL PLAN VIEW FRONT ELEVATION SIDE ELEVATION CONSUMER ACCESS DIMENSIONS

DIEBOLD 5550 CASH DISPENSER THROUGH 330mm (13) MAXIMUM WALL PLAN VIEW FRONT ELEVATION SIDE ELEVATION CONSUMER ACCESS DIMENSIONS L0 CLL -800--600 R DIEBOLD 0 CSH DISPENSER THROUGH 0mm (") MXIMUM WLL mm ( " ) UL CONSULT WITH DIEBOLD INSTLLTION/SERVICE BRNCH FOR DDITIONL DETILS ND INFORMTION. PLESE SEE PLNNING ND SITE PREPRTION GUIDE

More information

NET-ACCESS S TYPE VED READY CABINET 600mm WIDE X 1200mm DEEP FAMILY 12V343ST-DC VED TOP CAP FRONT PERFORATED SINGLE HINGE DOOR SPLIT SIDE PANEL

NET-ACCESS S TYPE VED READY CABINET 600mm WIDE X 1200mm DEEP FAMILY 12V343ST-DC VED TOP CAP FRONT PERFORATED SINGLE HINGE DOOR SPLIT SIDE PANEL THIS COPY IS PROVIDED ON RESTRICTED SIS ND IS NOT TO E USED IN NY WY DETRIMENTL TO THE INTERESTS OF PNDUIT CORP. PNEL VED TOP CP PERFORTED SINGLE HINGE PNEL SOLID RER NET-CCESS S TYPE VED REDY CINET 600mm

More information

SEE PAGES 3 AND 4 OF 7 FOR 3700 CASH RECYCLER THROUGH THE WALL WITH VESTIBULE TRIM KIT REFERENCE FRONT EDGE OF BEZEL FOR DEPTH DIMENSIONS

SEE PAGES 3 AND 4 OF 7 FOR 3700 CASH RECYCLER THROUGH THE WALL WITH VESTIBULE TRIM KIT REFERENCE FRONT EDGE OF BEZEL FOR DEPTH DIMENSIONS R DIEBOLD 00 LOBBY CSH RECYCLER- RER LOD L2 CLL -0--600 64 SFE (2 6 ") 40mm ( 6") CEN I SFE - " DISPLY OR " DISPLY WITH DETILS FOR OPTIONL VESTIBULE INSTLLTION CONSULT WITH DIEBOLD INSTLLTION/SERVICE BRNCH

More information

WATERTIGHT AIRTIGHT SPECIAL ACCESS DOORS & HATCHES, PART 1 GENERAL

WATERTIGHT AIRTIGHT SPECIAL ACCESS DOORS & HATCHES, PART 1 GENERAL SECTION 08316 WTERTIGHT IRTIGHT SPECIL CCESS DOORS & HTCHES, PRT 1 GENERL HIGHLIGHTED RES TO BE INSERTED BY SPECIFYING ENGINEER. 1.1 WORK OF THIS SECTION. THE WORK OF THIS SECTION INCLUDES PROVIDING LL

More information

THIS COPY IS PROVIDED ON A RESTRICTED BASIS AND IS NOT TO BE USED IN ANY WAY DETRIMENTAL TO THE INTERESTS OF PANDUIT CORP.

THIS COPY IS PROVIDED ON A RESTRICTED BASIS AND IS NOT TO BE USED IN ANY WAY DETRIMENTAL TO THE INTERESTS OF PANDUIT CORP. THIS COPY IS PROVIDED ON RESTRICTED SIS ND IS NOT TO E USED IN NY WY DETRIMENTL TO THE INTERESTS OF PNDUIT CORP. SIDE PNEL 2 TOP CP PERFORTED SINGLE HINGE KNOCK-OUTS FOR PDU POWER CORD SIDE PNEL RER PERFORTED

More information

Directional Control Valves. General Description. Features. Specifications

Directional Control Valves. General Description. Features. Specifications echnicl Informtion Generl Description directionl control vlves re high performnce, 5-chmer, direct operted, wet rmture, solenoid controlled, 3 or 4-wy vlves. hey re ville in 2 or 3-position nd conform

More information

SECTION A-A

SECTION A-A 40.08 D 8 6 5 4 3 2 1 WRNING: IF THERE RE NY DISCREPNCIES ETWEEN THE CD FILE ND THE DRWING, THE DRWING WILL TKE PRECEDENCE. IF IN DOUT, SK. D C 51.1 48 20.25 18 C 23.68 15.12 NOTE: DRWER UNIT NOT INCLUDED,

More information

PRODUCT SPECIFICATION C00 Converter. 48/36V to 12V, 20 Amps w/switched Output

PRODUCT SPECIFICATION C00 Converter. 48/36V to 12V, 20 Amps w/switched Output ISIONS DESCRIPTION DTE BY 001 3826 PRODUCTION RELESE 8/21/03 BF 002 4650 DD 6 PIN MTING CONNECTOR PN S 10/12/05 BF 003 4969 GENERL DOCUMENT MODIFICTIONS 6/29/0 GF 5065 ELECTRICL CHRCTERISTICS CHNGES 11/1/0

More information

330mm (13") MAXIMUM WALL THICKNESS IN AREA OF UNIT. 330mm (13") MAXIMUM WALL THICKNESS IN AREA OF UNIT (2) EACH SIDE OF SAFE CEN I SAFE ONLY

330mm (13) MAXIMUM WALL THICKNESS IN AREA OF UNIT. 330mm (13) MAXIMUM WALL THICKNESS IN AREA OF UNIT (2) EACH SIDE OF SAFE CEN I SAFE ONLY L08 CLL -800--600 R CS 0 FULL FUNCTION TERMINL " OR " DISPLY - THROUGH THE WLL 0mm (") 40mm ( 6") CEN I, CEN III GS OR CEN IV GS SFES SFE CONSULT WITH DIEBOLD INSTLLTION/SERVICE BRNCH FOR DDITIONL DETILS

More information

203mm (8") MAXIMUM WALL THICKNESS IN AREA OF UNIT NOTE: 203mm (8") MAXIMUM WALL THICKNESS IN AREA OF UNIT (2) EACH SIDE OF SAFE CEN I SAFE ONLY

203mm (8) MAXIMUM WALL THICKNESS IN AREA OF UNIT NOTE: 203mm (8) MAXIMUM WALL THICKNESS IN AREA OF UNIT (2) EACH SIDE OF SAFE CEN I SAFE ONLY L0 CLL -800--600 R CS 0 FULL FUNCTION VESTIBULE TERMINL " OR " DISPLY-THROUGH 0mm ( MXIMUM WLL 40mm ( 6") CEN I, CEN III GS or CEN IV GS SFES SFE ( 6 ") CONSULT WITH DIEBOLD INSTLLTION/SERVICE BRNCH FOR

More information

Plug-in connectors for power electronics

Plug-in connectors for power electronics Courtesy of Steven Engineering, Inc. - 230 Ryn Wy, South Sn Frncisco, CA 980-5370 - Min Office: (650) 588-9200 - Outside Locl Are: (800) 258-9200 - www.stevenengineering.com 480 PHOENIX CONTACT Plug-in

More information

Lincoln Under-cabinet Light Installation Instructions

Lincoln Under-cabinet Light Installation Instructions Lincoln Under-cbinet Light Instlltion Instructions #1500178 Rev A Congrtultions on your new Lincoln Under-cbinet Light! Whether purchsed for its significnt energy svings nd efficiency, lower lifetime costs,

More information

THIS COPY IS PROVIDED ON A RESTRICTED BASIS AND IS NOT TO BE USED IN ANY WAY DETRIMENTAL TO THE INTERESTS OF PANDUIT CORP.

THIS COPY IS PROVIDED ON A RESTRICTED BASIS AND IS NOT TO BE USED IN ANY WAY DETRIMENTAL TO THE INTERESTS OF PANDUIT CORP. THIS COPY IS PROVIDED ON RESTRICTED SIS ND IS NOT TO E USED IN NY WY DETRIMENTL TO THE INTERESTS OF PNDUIT CORP. DUL HINGE PERFORTED FRONT SPLIT SIDE PNEL SOLID SELED RER SPLIT SIDE PNEL VED REDY INTEGRL

More information

RPEA3-06. Functional Description HA /2011. Directional Control Valves Solenoid Operated with 8W Coil. Replaces HA /2007

RPEA3-06. Functional Description HA /2011. Directional Control Valves Solenoid Operated with 8W Coil. Replaces HA /2007 Directionl Control Vlves Solenoid Operted with 8W Coil RPEA3-06 0/20 Size 06 (D 03) 350 br (5076 PSI) 80 L/min (2 GPM) Replces 2/2007 /3-, /2- wy directionl control vlves Enclosure type to IP65 Push button

More information

CS 7780 FULL FUNCTION DRIVE-UP TERMINAL

CS 7780 FULL FUNCTION DRIVE-UP TERMINAL L CLL -800--600 CS 80 FULL FUNCTION DRIVE-UP TERMINL mm ( ") UL - "or " DISPLY THROUGH 0mm (8") MXIMUM WLL CONSULT WITH DIEBOLD NIXDORF INSTLLTION/SERVICE BRNCH FOR DDITIONL DETILS ND INFORMTION. PLESE

More information

4/2- and 4/3-directional spool valve solenoid-operated, direct-acting 4WE 6

4/2- and 4/3-directional spool valve solenoid-operated, direct-acting 4WE 6 4/2- nd 4/3-directionl spool vlve solenoid-operted, direct-cting 4WE 6 DESCRIION HYDC 4/2- nd 4/3- directionl spool vlves of the 4WE 6 series re directionl vlves for oil hydrulic systems which re used

More information

4/3-4/2 Directional valve elements L8_81 (ED4-P1) with or without LS connections. RE Edition: Replaces:

4/3-4/2 Directional valve elements L8_81 (ED4-P1) with or without LS connections. RE Edition: Replaces: 4/ - 4/ Directionl vlve elements L8_81 with proportionl (ED4-1) control nd with or without LS connections L8_81 (ED4-1) RE 181-1 Edition: 9.18 Replces: 7.1.17 Size Series Mximum operting pressure r (4

More information

2/2, 3/2 and 4/2 directional poppet valve with solenoid actuation

2/2, 3/2 and 4/2 directional poppet valve with solenoid actuation 0/0 /, / nd / directionl poppet vlve with solenoid ctution.7 Type M-.SEW...LX Size Up to 0 r Up to 0 L/min Contents Function nd configurtion Symols 0 Specifiction 0 Technicl dt 0 Electricl dt 0 Chrcteristic

More information

OPTIONAL 178mm (7") SPACER AVAILABLE FOR WALL THICKNESSES UP TO 152mm (6") 330mm (13") MAXIMUM WALL THICKNESS IN AREA OF UNIT

OPTIONAL 178mm (7) SPACER AVAILABLE FOR WALL THICKNESSES UP TO 152mm (6) 330mm (13) MAXIMUM WALL THICKNESS IN AREA OF UNIT L88 CLL -0--600 R DIEBOLD 0 CSH RECYCLER WITH COIN 40mm ( 6") CEN I, CEN III GS or CEN IV GS SFES THROUGH 0mm (") MXIMUM WLL 64 SFE CONSULT WITH DIEBOLD INSTLLTION/SERVICE BRNCH FOR DDITIONL DETILS ND

More information

TFM 1600 Seat Body Material: Stainless. PTFE Seat Body Material: Stainless and Brass. Catalog No. V81-5 Sept. 2008

TFM 1600 Seat Body Material: Stainless. PTFE Seat Body Material: Stainless and Brass. Catalog No. V81-5 Sept. 2008 Ctlog No. V81-5 Sept. 2008 Vlve with lever hndle Working pressure sets: 68.9 br (1000 psig) TFM sets: 137 br (2000 psig) Vlve with butterfly hndle Working pressure sets: 68.9 br (1000 psig) TFM sets not

More information

Print This Page. Return To Index

Print This Page. Return To Index PLASTI-BOND REDH2OT KNOCKOUT HUBS KNOCKOUT HUBS PRST2 PRSTG2 Knockout Hubs Specifictions Knockout Hubs Configurtions ST STG2 b c STTB STTTB d COMPLIANCES PLASTI-BOND REDH 2 OT ST style knockout hubs re

More information

Fire dampers. The art of handling air. Type FKA-EU tested to EN FKA-EU/DE/BE/en. according to Declaration of Performance

Fire dampers. The art of handling air. Type FKA-EU tested to EN FKA-EU/DE/BE/en. according to Declaration of Performance FKA-EU/DE/BE/en Fire dmpers Type FKA-EU tested to EN 1366-2 ccording to Declrtion of Performnce DoP / FKA-EU / DE / 2013 / 001 The rt of hndling ir Contents Description Description 2 Correct use 3 Construction

More information

R E V I S I O N REV. DRAWN BY ECO No DESCRIPTION DATE APPROVED BILL OF MATERIALS

R E V I S I O N REV. DRAWN BY ECO No DESCRIPTION DATE APPROVED BILL OF MATERIALS NOTES: UNLESS OTHERWISE SPECIFIED. CORNERS DRWN SHRP TO E R.005 MXIMUM. 2. EXTERIOR SURFCE TEXTURE TO E EQUIVLENT TO MT-007. TEXTURE ON ENCLOSURE WILL VRY FROM TIME TO TIME S THE TOOL WERS ND IT ECOMES

More information

Decor Radiators Baseboard

Decor Radiators Baseboard Decor Rditors Bsebord Pedestl 11 (with fins) Avilble in outputs from 1,561 to 10,282 Btu/hr; 2, nd 4 tubes high. 28 (igh Output, with fins) Avilble in outputs from 5,05 to 19,552 Btu/hr; 2 nd 4 tubes high.

More information

DIEBOLD IN LOBBY TELLER (ILT) PORTRAIT OR LANDSCAPE INSTALLED WITH A COIN RECYCLER SIDE CAR PLAN FRONT VIEW SIDE VIEW PAGE 1 OF 7

DIEBOLD IN LOBBY TELLER (ILT) PORTRAIT OR LANDSCAPE INSTALLED WITH A COIN RECYCLER SIDE CAR PLAN FRONT VIEW SIDE VIEW PAGE 1 OF 7 L2 CLL -800--600 TP-826-00. R CONSULT WITH DIEBOLD INSTLLTION/SERVICE BRNCH FOR DDITIONL DETILS ND INFORMTION. PLESE SEE PLNNING ND SITE PREPRTION GUIDE DIEBOLD 00 - IN LOBBY TELLER (ILT) PORTRIT OR LNDSCPE

More information

CC-410 KIT SERIES INSTRUCTION SHEET

CC-410 KIT SERIES INSTRUCTION SHEET (COMPLETE CC-410-W KIT ILLUSTRTED. CUT-OUTS IN TRCK & FSCI TO EXPOSE COMPONENTS) CC-410 KIT SERIES INSTRUCTION SHEET CROWDERTRCK S CTCH N CLOSE TM SYSTEM PREVENTS BOUNCING ND SLMG OF SLIDING DOORS. CN

More information

DIEBOLD 3700 LOBBY CASH RECYCLER- FRONT LOAD 15" DISPLAY OR 19" DISPLAY CEN I, CEN III GAS, CEN IV GAS or CEN IV GAS EX SAFES

DIEBOLD 3700 LOBBY CASH RECYCLER- FRONT LOAD 15 DISPLAY OR 19 DISPLAY CEN I, CEN III GAS, CEN IV GAS or CEN IV GAS EX SAFES R L CLL -0--600 64 SFE ( 6 ") DIEBOLD 00 LOBBY CSH RECYCLER- FRONT LOD " DISPLY OR " DISPLY CEN I, CEN III GS, CEN IV GS or CEN IV GS EX SFES CONSULT WITH DIEBOLD INSTLLTION/SERVICE BRNCH FOR DDITIONL

More information

Special Valves. Connection size G1/8 to G2. Contents Version Actuation Port size Page Characteristics. Instructions Overview. Electrical G1/8 G1/4

Special Valves. Connection size G1/8 to G2. Contents Version Actuation Port size Page Characteristics. Instructions Overview. Electrical G1/8 G1/4 Contents Version Actution Port size Pge Chrcteristics Dimensions 3/2, 5/2 nd 5/3 Wy Vlves with NAMURconnections Series S9 5/2 Wy Vlves for Two Hnd Opertion Series S9 Time Dely Vlve for 2-Hnd Sfety Strt

More information

2/2 4/4 Solenoid Directional Seat Valve, ISO Size 03

2/2 4/4 Solenoid Directional Seat Valve, ISO Size 03 2/2 4/4 Solenoid Directionl Set Vlve, ISO Size 03 Q mx = 40 l/min (11 gpm), p mx = 315 r (4500 psi) idirectionl lek-proof shutoff, direct cting, electriclly operted Series W2N, W2 1 Description With crtridge

More information

See pages 2, 7 and 8 for ATEX ratings OUTLINE, PUMP, S1F, CENTER PORTED AIR VALVE No-lube, no-stall design H.1

See pages 2, 7 and 8 for ATEX ratings OUTLINE, PUMP, S1F, CENTER PORTED AIR VALVE No-lube, no-stall design H.1 H.1 REVISED DRWING MF 4/23/2010 REV REVISION CHG DTE PP DTE ECN PRT NUMBER MTERIL PUMP REFERENCE MDE FROM SS'Y REFERENCE UNLESS OTHERWISE SPECIFIED TOLERNCES.XX.010.XXX.005 DESCRIPTION NGULR 1/2 SURFCE

More information

WARNING: IF THERE ARE ANY DISCREPANCIES BETWEEN THE CAD FILE AND THE DRAWING, THE DRAWING WILL TAKE PRECEDENCE. IF IN DOUBT, ASK.

WARNING: IF THERE ARE ANY DISCREPANCIES BETWEEN THE CAD FILE AND THE DRAWING, THE DRAWING WILL TAKE PRECEDENCE. IF IN DOUBT, ASK. 28.48 DJUSTLE 5.64 19.78 DJUSTLE D 8 7 6 5 4 3 2 1 20.37 WRNING: IF THERE RE NY DISCREPNCIES ETWEEN THE CD FILE ND THE DRWING, THE DRWING WILL TKE PRECEDENCE. IF IN DOUT, SK. D 51.80 48.00 9.57 C C 18.00

More information

9900 IN LOBBY TELLER - (ILT) PORTRAIT AND LANDSCAPE DISPLAY PLAN FRONT VIEW SIDE VIEW PAGE 1 OF 6 CALL

9900 IN LOBBY TELLER - (ILT) PORTRAIT AND LANDSCAPE DISPLAY PLAN FRONT VIEW SIDE VIEW PAGE 1 OF 6 CALL 00 IN LOBBY TELLER - (ILT) PORTRIT ND L CLL -800--600 40mm ( 6") CEN I / CEN III GS / CEN IV GS SFES CONSULT WITH DIEBOLD INSTLLTION/SERVICE BRNCH FOR DDITIONL DETILS ND INFORMTION. PLESE SEE PLNNING ND

More information

4/2 and 4/3 Solenoid Directional Valve, ISO Size 03

4/2 and 4/3 Solenoid Directional Valve, ISO Size 03 4/ nd 4/3 Solenoid Directionl Vlve, ISO Size 03 Q mx = 60 l/min, p mx = 315 r wo-stge design, with EX-sfty solenoid coil Vlve: High switching relilility thnks to two-stge follower spool design Slip-on

More information

152mm (6") DIA. POINT TO POINT SYSTEM PVC OR STEEL TUBE SYSTEM TYPE I AND TYPE II OVERHEAD UNITS TYPE I OVERHEAD UNIT TYPE II OVERHEAD UNIT NOTES:

152mm (6) DIA. POINT TO POINT SYSTEM PVC OR STEEL TUBE SYSTEM TYPE I AND TYPE II OVERHEAD UNITS TYPE I OVERHEAD UNIT TYPE II OVERHEAD UNIT NOTES: 2mm ") DI. POINT TO POINT SYSTEM PVC OR STEEL SYSTEM L84 CLL -800--600 TYPE I ND TYPE II OVERHED UNITS 4 6 ") ( 8 ") 6 8 ") ( -0 PLN VIEW 20 (8 28 8 ") ( 8 ") 4 ( -4") 2 (4 ( 8 ") 28 ( 8 ") THE TYPE I

More information

COIN DISPENSER SIDE CAR FOR INSTALLATION NEXT TO DIEBOLD IN LOBBY TELLER (ILT) PLAN FRONT VIEW SIDE VIEW PAGE 1 OF 7 CALL

COIN DISPENSER SIDE CAR FOR INSTALLATION NEXT TO DIEBOLD IN LOBBY TELLER (ILT) PLAN FRONT VIEW SIDE VIEW PAGE 1 OF 7 CALL SIDE CR FOR INSTLLTION NEXT TO DIEBOLD 00 - IN LOBBY TELLER (ILT) L2 CLL -800--600 CONSULT WITH DIEBOLD INSTLLTION/SERVICE BRNCH FOR DDITIONL DETILS ND INFORMTION. PLESE SEE PLNNING ND SITE PREPRTION GUIDE

More information

KDA 24 SERIES OPERATOR MANUAL. KEPCO An ISO 9001 Company. ALARM MODULE I INTRODUCTION II FEATURES

KDA 24 SERIES OPERATOR MANUAL. KEPCO An ISO 9001 Company. ALARM MODULE I INTRODUCTION II FEATURES OPERTOR MNUL KEPCO n ISO 001 Company. KD 24 SERIES KD 24 SERIES LRM MODULE I INTRODUCTION SCOPE OF MNUL. This Operator Manual covers the installation, checkout and operation of the KD 24 Series larm Modules.

More information

Hot Air Thermostats. WTHc series. Special features. Brief description. Switching function. Approval/approval marks (see "Technical data")

Hot Air Thermostats. WTHc series. Special features. Brief description. Switching function. Approval/approval marks (see Technical data) Delivery ddress: Mckenrodtstrße 36039 Fuld, Germny Postl ddress: 36035 Fuld, Germny Phone: +9 66 6003-0 Fx: +9 66 6003-607 E-mil: mil@jumo.net Temple Bnk, Riverwy Hrlow, Essex CM0 DY, UK Phone: + 79 635533

More information

Precision Pressure Transmitter with Switching Contacts and Display. Interface Setup program. Display 4 characters. Switching output 1.

Precision Pressure Transmitter with Switching Contacts and Display. Interface Setup program. Display 4 characters. Switching output 1. Dt sheet 405054 Pge 1/7 JUMO DLOS HP Precision Pressure Trnsmitter with Switching Contcts nd Disply Appliction Hydrulic plnts Mchine nd plnt engineering Test benches Lbortory equipment Brief description

More information

UBAN Series. Direct operated pressure reducing valve. Suitable for: Air & process gases. Liquids. Steam. Markets: Oil & gas. Blanketing systems

UBAN Series. Direct operated pressure reducing valve. Suitable for: Air & process gases. Liquids. Steam. Markets: Oil & gas. Blanketing systems UBAN Series Direct operted pressure reducing vlve Suitble for: Air & process gses Liquids Stem Mrkets: Oil & gs Blnketing systems Generl industry Power CC0032E - Rev. 1 14/01/2010 UB REGULATORS UBAN Series:

More information

SSAB Water mains PIPES AND FITTINGS

SSAB Water mains PIPES AND FITTINGS SSAB Wter mins PIPES AND FITTINGS Pipes nd fittings mnufctured y SSAB re used primrily with wter pipeline sizes DN 400-1200. The fittings re mde of steel pressure pipes (ex works delivery) nd cn e coted

More information

Brazed heat exchanger XB

Brazed heat exchanger XB Description The XB is rnge of copper rzed plte het exchngers for use in District Heting (DH) nd District Cooling (DC) pplictions, e.g. domestic hot wter production, district heting susttion to seprte the

More information

POWER COMBICON Plugs and Headers PC 6/ for Currents up to 41 A, mm Pitch

POWER COMBICON Plugs and Headers PC 6/ for Currents up to 41 A, mm Pitch POWER COMBICON Plugs nd Heders PC 6/ for Currents up to 41 A, The PC 6 plug connector fetures highly conductive metl lloys to offer current crrying cpcity of 41 A t rted voltge of 1000 V. A double steel

More information

Spring Return DuraDrive Two-Position Actuator

Spring Return DuraDrive Two-Position Actuator MA40-704x Series, MA4-707x Series, nd MA4-75x Series Spring Return DurDrive Two-Position Actutor For spring return pplictions tht require twoposition control of dmpers nd vlves in HVAC system. Fetures:

More information

6/2 way directional valve type 6/2UREM6 and 6/2URMM6

6/2 way directional valve type 6/2UREM6 and 6/2URMM6 6/2 wy directionl vlve type 6/2UREM6 nd 6/2URMM6 NS 6 dm 3 up to 35 MP up to 5 /min DT SHEET - SERVICE MNU NUL WK 421 54 11.212 PPLICTION Moile 6 wy 2 position stckle directionl vlves type 6/2UREM6...

More information

Electrically controlled directional control poppet valve type UREZ6

Electrically controlled directional control poppet valve type UREZ6 LICION Electriclly controlled directionl control poppet vlve type UREZ6 is intended for chnging the direction of hydrulic fluid flow in system, which llows for chnge of the direction of the receiver motion

More information

Model 1001/1001HPS Drinking Fountain

Model 1001/1001HPS Drinking Fountain INSTLLTION, OPERTION & MINTENNCE INSTRUCTIONS Kleppe Lane Sparks, NV 89-667 (77) 9-72 Fax (77) 9-72 E-mail: haws@hawsco.com website: www.hawsco.com Model 00/00HPS Drinking Fountain No. 20760(9) NOTE TO

More information

GLM PULSA ENGINEERED PRODUCTS PULSA.COM/PULSAGLM. Flow: up to 845 gph (3,200 lph) Pressure: up to 175 psi (12 bar)

GLM PULSA ENGINEERED PRODUCTS PULSA.COM/PULSAGLM. Flow: up to 845 gph (3,200 lph) Pressure: up to 175 psi (12 bar) ENGINEERED PRODUCTS Flow: up to 845 gph (3,200 lph) Pressure: up to 175 psi (12 bar) Temperature: from 32 to 113 F (0-45 C) ccuracy: +/- 2% of Set Point PULS GLM MECHNICL DIPHRGM METERING PUMP PULS.COM/PULSGLM

More information

Name Model Description/Function. Directional Control Valve Station 5914 Used to activate the Pneumatic Box Feeder B

Name Model Description/Function. Directional Control Valve Station 5914 Used to activate the Pneumatic Box Feeder B Job Sheet 4 PLC-Controlled Conveyor nd Sensors OBJECTIVE To fmilirize yourself with the vrious sensors provided with the Flexible Mnufcturing System nd mesure their respective sensing rnges. To use the

More information

Data Sheet T /4/5/6 EN

Data Sheet T /4/5/6 EN Dt heet T 8310-1/4/5/6 EN Pneumtic Actutors up to 750v2 cm² Type 3271 Type 3277 for integrl positioner ttchment Appliction Liner ctutors prticulrly suitble for ttchment to eries 240, 250, 280 nd 290 Vlves

More information

DIESEL EGT GAUGE INSTALLATION INSTRUCTIONS P14D AA

DIESEL EGT GAUGE INSTALLATION INSTRUCTIONS P14D AA DIESEL EGT GUGE INSTLLTION INSTRUCTIONS P4D4-9235- Revision: - Dated 3/9/4 Replaces: None DIESEL EGT GUGE INSTLLTION HRDWRE CONTENTS P4D4-44- - DIESEL EGT GUGE KIT COMPONENT - DIESEL EGT GUGE SSY (PRT

More information

RTD Temperature Sensor omnigrad S- TR 88

RTD Temperature Sensor omnigrad S- TR 88 Technicl informtion TI 271T/02/en 60021058 RTD Temperture Sensor omnigrd S- TR 88 RTD ssembly with extension neck Replceble insert PCP (4...20 ma), HART or PROFIBUS-PA electronics The TR 88 Omnigrd S rnge

More information

MPC COBRA SERIES. Manually Programmable Cylindrical Lock D

MPC COBRA SERIES. Manually Programmable Cylindrical Lock D 51120-D MPC COBRA SERIES Mnully Progrmmle Cylindricl Lock 575 Birch Street Forestville, CT 06010 technicl support: 866-322-1237 fx: 866-322-1233 http://www.irsupport.net 57010-H 12-19-2005 Introduction

More information

2/2, 3/2 and 4/2 directional seat valve with mechanical, manual or fluidic operation

2/2, 3/2 and 4/2 directional seat valve with mechanical, manual or fluidic operation /, / nd / directionl set vlve with mechnicl, mnul or fluidic opertion RE 0/10.06 /1 ype M-.S.. Sizes 6 nd 10 Component series X Mximum operting pressure 0/ r Mximum flow 0 l/min H701+70+70 le of contents

More information

POWER BUTTON: 25mm (1") CONDUIT X 3048mm (10'-0") LONG TO HOUSE POWER AND CONTROL CABLES (SUPPLIED BY DIEBOLD)

POWER BUTTON: 25mm (1) CONDUIT X 3048mm (10'-0) LONG TO HOUSE POWER AND CONTROL CABLES (SUPPLIED BY DIEBOLD) R Easy-aire GX PNEUMTIC DELIVERY SYSTEM 24mm(") DI. PNEUMTIC TUBE SYSTEM 86G OPERTOR ND 8G CUSTOMER DETILS L962 CLL -8-999-6 OPERTOR CONTROL PNEL PROJECTION FILE NO. 8-26 REV. SUBJECT TO CHNGE W ITHOUT

More information

Ex-proof proportional valves multicertification ATEX, IECEx, EAC

Ex-proof proportional valves multicertification ATEX, IECEx, EAC Tble F600-5/E Ex-proof proportionl vlves multicertifiction ATEX, IECEx, EAC DLHZA-T-040 vlve body ex-proof solenoid ex-proof trnsducer (only for proportionl -T vlves) threded connections for cble clmp

More information

ADCATROL INTERMITTENT BLOWDOWN VALVES VPA 26 (Fabricated steel)

ADCATROL INTERMITTENT BLOWDOWN VALVES VPA 26 (Fabricated steel) TROL INTERMITTENT BLOWDOWN VLVES VP 26 (Fabricated steel) DESCRIPTION The VP26 blowdown valve was specially designed for application on steam boilers removing the concentrations of solids avoiding boiler

More information

* * * 3700 LOBBY CASH RECYCLER. REAR LOAD 13mm ( 2") UL SAFE - 15" DISPLAY OR 19" DISPLAY WITH DETAILS FOR OPTIONAL VESTIBULE INSTALLATION

* * * 3700 LOBBY CASH RECYCLER. REAR LOAD 13mm ( 2) UL SAFE - 15 DISPLAY OR 19 DISPLAY WITH DETAILS FOR OPTIONAL VESTIBULE INSTALLATION R L CLL -0--600 64 SFE ( 6 ") DIEBOLD 00 LOBBY CSH RECYCLER RER LOD mm ( ") UL SFE - " DISPLY OR " DISPLY WITH DETILS FOR OPTIONL VESTIBULE INSTLLTION CONSULT WITH DIEBOLD INSTLLTION/SERVICE BRNCH FOR

More information

MANHOLE GRADE RING HEIGHT = 40mm*, 50mm, 75mm 75mm WITH STEP CON CAST PIPE STENCIL ISOMETRIC VIEW MATERIAL LIST PLAN VIEW PRODUCT VARIABLES

MANHOLE GRADE RING HEIGHT = 40mm*, 50mm, 75mm 75mm WITH STEP CON CAST PIPE STENCIL ISOMETRIC VIEW MATERIAL LIST PLAN VIEW PRODUCT VARIABLES CCP-OKVILLE (HEIGHT) ( OF MFG) LUM. STEP FOR GM00752 ONLY 54 102 715 95 D5 855 HOOP STEEL 150 LP OR BUTT WELD 991 MTERIL LIST QTY E REMRK 1 E LUMIN. STEP FOR 75mm ONLY 1 E HOOP STEEL RD. 855 X D5 PLN VIEW

More information

DPST-NO None 2 channels Auto-reset Inverse 24 VAC/VDC G9SB-2002-A 4 1 channel or 2

DPST-NO None 2 channels Auto-reset Inverse 24 VAC/VDC G9SB-2002-A 4 1 channel or 2 Sfety Rely Unit Ultr Slim Sfety Rely Unit Models of width 17.5 mm vilble with 2 or 3 poles. Models of width 22.5 mm with 3 poles lso vilble. Conforms to EN stndrds. (TÜV pprovl) DIN trck mounting possible.

More information

631 ALLOWANES AND TOLERANCES

631 ALLOWANES AND TOLERANCES 631 ALLOWANES AND TOLERANCES ANSI Fits. Tbles 3 through 9 inclusive show series of stndrd types nd clsses of fits on unilterl hole bsis, such tht the fit produced by mting prts in ny one clss will produce

More information

CCD-493 KIT SERIES INSTRUCTION SHEET

CCD-493 KIT SERIES INSTRUCTION SHEET (COMPLETE CCD-493-W KIT ILLUSTRTED. CUT-OUTS IN TRCK TO EXPOSE COMPONENTS) CCD-493 KIT SERIES INSTRUCTION SHEET CROWDERTRCK S CTCH N CLOSE TM SYSTEM PREVENTS BOUNCING ND SLMMING OF SLIDING S. CN BE INSTLLED

More information

Solenoid Pilot Operated Directional Control Valve

Solenoid Pilot Operated Directional Control Valve Contct Detils efore using the product, plese check the http://www.dikinpmc.com/en/ For ltest informtion, DF ctlogs nd opertion mnuls Solenoid ilot Operted Directionl Control Vlve Fetures hese models relize

More information

Two-Position Electric Duplex Room Thermostats

Two-Position Electric Duplex Room Thermostats TC-xx Series, TC-xx Series, TF- Series Two-Position Electric Duplex Room Thermostts These thermostts provide on-off control of heting/cooling systems. Fetures: Seprte units for C nd F. All units except

More information

EXPLOSION PROOF DIRECTIONAL CONTROL VALVE TYPE ED6 SERIE 6X NEC STANDARD

EXPLOSION PROOF DIRECTIONAL CONTROL VALVE TYPE ED6 SERIE 6X NEC STANDARD EXLOSION ROOF DIRECIONL CONROL VLVE YE ED SERIE X NEC SNDRD CRCERISICS Hydrulic : Cetop. Mximum pressure in service : r. Nominl Flow mx. : 0 l/mn.(see tle) Directionl control vlves re solenoid operted

More information

JUMO MIDAS C18 SW. OEM seawater pressure transmitter. Applications. Brief description. Customer benefits. Special features. Approvals/approval marks

JUMO MIDAS C18 SW. OEM seawater pressure transmitter. Applications. Brief description. Customer benefits. Special features. Approvals/approval marks Pge /8 JUMO MIDAS C8 SW OEM sewter pressure trnsmitter Applictions wter tretment reverse osmosis, e.g. sewter deslintion plnts purifiction plnts orgnic cids, e.g. cetic cid solutions contining chloride,

More information

MINI COMBICON Double-Level Headers for Through Hole Reflow Processes, MCDN 1,5/ 3.5 mm Pitch

MINI COMBICON Double-Level Headers for Through Hole Reflow Processes, MCDN 1,5/ 3.5 mm Pitch MINI COMBICON Double-Level Heders for Through Hole Reflow Processes, MCDN 1,5/ The MCDN(V) 1,5/ double-level heders feture minimum spce requirement on the PCB, nd t the sme time, high contct density. It

More information

* * * DIEBOLD 3700 LOBBY CASH RECYCLER- FRONT LOAD 15" DISPLAY OR 19" DISPLAY CONSUMER ACCESS DIMENSIONS PLAN VIEW 19" DISPLAY FRONT ELEVATION

* * * DIEBOLD 3700 LOBBY CASH RECYCLER- FRONT LOAD 15 DISPLAY OR 19 DISPLAY CONSUMER ACCESS DIMENSIONS PLAN VIEW 19 DISPLAY FRONT ELEVATION R L CLL -0--600 64 SFE ( 6 ") DIEBOLD 00 LOBBY CSH RECYCLER- FRONT LOD " DISPLY OR " DISPLY WITH mm ( ") UL SFE CONSULT WITH DIEBOLD INSTLLTION/SERVICE BRNCH FOR DDITIONL DETILS ND INFORMTION. PLESE SEE

More information

Pneumatic Actuators 1000, 1400, 2800, and 2 x 2800 cm² Type 3271 and Type 3277 for integral positioner attachment Hand-operated Actuator Type 3273

Pneumatic Actuators 1000, 1400, 2800, and 2 x 2800 cm² Type 3271 and Type 3277 for integral positioner attachment Hand-operated Actuator Type 3273 Pneumtic Actutors 000, 400, 2800, nd 2 x 2800 cm² Type 27 nd Type 277 for integrl positioner ttchment nd-operted Actutor Type 27 Appliction Liner ctutor in prticulr for ttchment to Series 240, 250, nd

More information

Appendix E D791 and T791 Head and Valve Holddown Assembly Details

Appendix E D791 and T791 Head and Valve Holddown Assembly Details Appendix E D nd T Hed nd Vlve Holddown Assemly Detils Hed First Stge Holddown Assemly (") Suction with Unloder Suction (Stndrd) First Stge Holddown Assemly (") Dischrge See figure A 0 CAUTION: Alwys relieve

More information

3-Way Ball Valve Assemblies Using TAC DuraDrive Actuators

3-Way Ball Valve Assemblies Using TAC DuraDrive Actuators 3-Wy Bll Vlve Assemblies Using TAC DurDrive Actutors Note: All vlve sizes ANSI Clss IV (0.01% of C v ) shut off, piped coil-side outlet to A. Tble-5 Selection Chrt3-Wy Mixing Bll Vlve Assemblies with TAC

More information

AIRCRAFT ENGINES SERVICE INSTRUCTION ENGINE START AT LOW TEMPERATURES AT ROTAX SI R1

AIRCRAFT ENGINES SERVICE INSTRUCTION ENGINE START AT LOW TEMPERATURES AT ROTAX SI R1 d03161 RECOMMENDED AIRCRAFT ENGINES SERVICE INSTRUCTION ENGINE START AT LOW TEMPERATURES AT ROTAX ENGINE TYPE 912 AND 914 (SERIES) Repeting symbols: Plese, py ttention to the following symbols throughout

More information

MISCELLANEOUS INDEX PAGE DATE SERIES DESCRIPTION

MISCELLANEOUS INDEX PAGE DATE SERIES DESCRIPTION MISCELLNEOUS INDEX 08/01/11 PGE DTE SERIES DESCRIPTION M-1 08/01/11 Miscellaneous Index M-2 04/16/96 M01 Tooling all M-3 04/16/96 M02 Scrap Chute Hook and Retainer racket M-4 01/03/95 M03 Scrap Chute Chain

More information

4/3, 4/2 and 3/2 explosion-proof solenoid directional valve

4/3, 4/2 and 3/2 explosion-proof solenoid directional valve 01/06 4/3, 4/2 nd 3/2 explosion-proof solenoid directionl vlve Type G...WE6...L6X 2.21 Size (NG) 6 Up to 350 br Up to 80 L/min Contents Function nd configurtion Specifictions 03 Spool symbols 03 Technicl

More information

JUMO MIDAS S05 OEM pressure transmitter - universal

JUMO MIDAS S05 OEM pressure transmitter - universal Delivery ddress: Mckenrodtstrße 4 609 Fuld, Germny Postl ddress: 605 Fuld, Germny Phone: +49 66 600-0 Fx: +49 66 600-607 Hrlow, Essex CM0 DY, UK Phone: +44 79 655 Fx: +44 79 656 Cnstot, NY 0, USA Phone:

More information

1318/ V BATTERY SEPARATOR

1318/ V BATTERY SEPARATOR ISIONS ECO DESCRIPTION DTE BY 001 4153 PRODUCTION RELESE 7/30/04 BF 002 5188 CHNGE TRQ FRM 60±10 TO 50±5 IN/LBS & DD e-mrk TO LBEL 7/16/08 BF 003 5355 DD TRNSIENT PROTECTION 1/16/09 JT 5369 REDUCE ESD

More information