1 TITLE: Engineering Specification RECOMMENDED: S. Edey NO: 1 REV: APPROVED: D. O Keefe. LLS0002 OF REV. DATE: City of Ottawa Street Lighting HID Shoebox Style Luminaire For City of Ottawa Use Only
2 REVISION SHEET REVISION DESCRIPTION DATE INITIAL 1 Add detailed drawings LBS csm/jb LLS0010, LLS0011, and LLS0012. Removed Figure 1 reference Text and Drawing 2 Title renamed General Conditions referenced in separate specification Electrical Characteristics referenced in separate specification Revised scope, light distribution & marking csm jb 3 Associated Standard Drawings identified (11.0) Revised Marking, (4.7.1) Added reference to electrical characteristics (4.13) 4 Approval and Recommended authorization changed jb se do For Hydro Ottawa Use Only LLS0002 Rev.4 Page 2 of 9
3 TABLE OF CONTENTS 1.0 GENERAL SCOPE REFERENCE STANDARDS APPROVAL OF SOURCE PHYSICAL CHARACTERISTICS MOUNTING ARRANGEMENT TERMINAL BLOCK AND GROUND LUG CONNECTION DIAGRAM REFLECTOR BALLAST, STARTER AND CAPACITORS LAMP SOCKET MARKING HOUSING GLASS LENS LIGHT DISTRIBUTION PATTERN COLOUR AND FINISHING TWIST LOCK RECEPTACLE ELECTRICAL CHARACTERISTICS INSPECTION PACKAGING AND SHIPPING WARRANTY INSTRUCTIONS TO BIDDERS GENERAL EXCEPTIONS MODIFICATIONS TECHNICAL INFORMATION REQUESTED SAMPLES MAINTENANCE PARTS INFORMATION SUPPLIED TO THE BIDDERS DRAWINGS... 9 For Hydro Ottawa Use Only LLS0002 Rev.4 Page 3 of 9
4 1.0 General 1.1 Scope This specification covers the supply of High Pressure Sodium and Metal Halide shoebox type luminaires complete with integral ballast and mounting bracket. This specification section shall be read in conjunction with engineering specification LGC0001 and LLS Reference Standards Luminaires shall comply with all applicable requirements in the latest issues of the following standards: ANSI/IES RP-8 Roadway Lighting ANSI Standard C Specifications for 70W S62 High Pressure Sodium Lamps ANSI Standard C Specifications for 100W S54 High Pressure Sodium Lamps ANSI Standard C Specifications for 150W S55 High Pressure Sodium Lamps ANSI Standard C82.9 Definitions for HID Lamp Ballasts and Transformers ANSI Standard C Lock-type Photocontrol Devices and Mating Receptacles Physical and Electrical Interchangeability and Testing ANSI Standard C Field Identification of High Intensity Discharge Lamps in Luminaires CSA Standard C22.2 No. 9 Luminaires CSA Standard C22.2 No. 43 Lampholders CSA Standard C22.2 No. 74 Equipment for use with Electric Discharge Lamps CSA Standard C22.2 No. 97 Outdoor and Submersible Floodlights CSA Standard C164 Hot Dip Galvanizing of Irregularly Shaped Articles CSA Standard C653 Performance Standards for Roadway Lighting Luminaires NEMA Standard OD Field Identification of High-Intensity Discharge Lamps in luminaires used in Roadway Lighting Equipment. 3.0 Approval Of Source Luminaires supplied to this specification shall be supplied only by manufacturers approved by the City of Ottawa or its agent. Only luminaires evaluated and approved by the City of Ottawa or its agent before or at the time a quotation is submitted will be accepted. Luminaires supplied shall be of the same construction as the sample luminaire currently approved by the City of Ottawa or its agent and, once approved, the supplier shall not change material, type or source or production method without prior approval of the City of Ottawa or its agent. 4.0 Physical Characteristics 4.1 Mounting Arrangement The luminaire and bracket shall be designed to mount on a round pole that has a minimum top diameter of 102 mm. The luminaire shall be horizontal when the bracket is mounted on a vertical surface. The bracket shall be capable of safely supporting the luminaire at a wind speed of 160 km/h. Refer to engineering specification LBS0001. For Hydro Ottawa Use Only LLS0002 Rev.4 Page 4 of 9
5 4.2 Terminal Block and Ground Lug A terminal block shall be provided and so placed that connection of No. 14 AWG solid copper supply wires to it will be convenient and easy to make without special tools. In addition, a ground lug shall be placed so that connection to it with a No. 14 AWG solid copper ground wire can be made easily without special tools. 4.3 Connection Diagram A connection diagram of a permanent material shall be located so as to be easily visible when making connections. 4.4 Reflector The reflector shall be made of polished, chemically brightened anodized aluminium not subject to distortion and shall be easily removable for servicing in the field without the use of special tools. 4.5 Ballast, Starter and Capacitors The ballast, starter and capacitors shall be mounted within the luminaire so that replacement may be achieved easily. Further, special precautions in the form of spacing and barriers shall be taken to shield the components from heat emitted by the lamp. Capacitors shall be non-pcb and permanently marked "Non-PCB". 4.6 Lamp Socket The standard lamp socket shall be a mogul screw base made from cold moulded porcelain and pulse rated for HPS and MH operation. The shell shall be nickel-plated with dimples or slots to prevent the lamp loosening with vibration and shall be secured to the socket using a machine screw and nut combination. The centre contact shall be nickel-plated and spring-loaded for positive contact. 4.7 Marking Each luminaire shall have an exterior identification marker affixed to the underside of the luminaire near the bracket that would be visible from the ground and indicate the size of lamp used in the luminaire. When an underside location is not appropriate, a selfadhesive label is to be supplied with the fixture and attached in the location as directed by the City of Ottawa Street Light agent Each luminaire shall have a permanent type nameplate indicating the manufacturer's name, catalogue/model number, wattage, supply voltage and frequency, input current and year of manufacture This nameplate may be a metallic nameplate attached to the luminaire with self-tapping crews or alternatively a high quality stick-on foil type label providing that the foil label is Installed at the place of manufacture under quality controlled conditions and will not fade, chip, peel or otherwise deteriorate under normal service conditions A permanent label including a wiring diagram and stating ballast type and compatible starter number and capacitor value shall be provided and attached to the ballast or interior of the luminaire so that it is clearly visible during maintenance operations. For Hydro Ottawa Use Only LLS0002 Rev.4 Page 5 of 9
6 4.8 Housing The luminaire housing shall be aluminium, designed and fabricated to minimize the ingress of moisture, insects and other foreign material. Suitable gaskets and filters shall be provided to minimize the accumulation of dirt on the lamp, reflector and glass lens. Removable covers shall be hinged so they hang freely in a vertical position to allow easy access to the lamp, socket, ballast, terminal block and ground connector for field servicing. In the closed position, all covers shall be secure and safe from damage due to vibration. Screw fastenings on doors are not preferred, but if used, screws must have Robertson type head. 4.9 Glass Lens The lens shall be flat tempered glass with high resistance to breakage from thermal shock and mechanical impact. The lens shall be easily removable for washing and maintenance, but fastened safely and securely to the door at all other times whether the door is open or closed Light Distribution Pattern Unless otherwise requested, luminaires shall be adjusted at the factory for the following light distribution patterns when used with the lamps indicated. Table 4.1 Luminaire Wattage (HPS) Factory Setting Luminaire Wattage (MH) Factory Setting 70 M-CO-II 250 M-CO-III 100 M-CO-II 400 M-CO-III 150 M-CO-II 200 M-CO-II 250 M-CO-III 400 M-CO-III 4.11 Colour and Finishing Except for the glass lens, all visible parts of the luminaire and bracket shall be finished to match as specified: White, Grey and Dark Bronze are acceptable colours. Paint shall be Epoxy Baked Enamel. Permanent anodizing to match is acceptable All finishes shall be applied in strict adherence to manufacturer's specifications Surfaces and edges shall be smooth and free from burrs and sharp corners Twist Lock Receptacle For Hydro Ottawa Use Only LLS0002 Rev.4 Page 6 of 9
7 The luminaire shall be equipped with a twist lock receptacle for a photoelectric controller. When installed, the photoelectric controller shall be adjustable for a north-facing window Electrical Characteristics Refer to LLS Inspection The City of Ottawa or its agent reserves the right to inspect the luminaires during manufacture for the purpose of ascertaining whether the units meet the requirements of this specification. 6.0 Packaging and Shipping Luminaires shall be shipped complete with hardware and bracket suitably packaged to ensure all parts are delivered as an entity. The supplier shall advise the City of Ottawa or its agent Purchasing Department three days prior to his shipping date of his intent to deliver. 7.0 Warranty The manufacturer shall warrant that the luminaires and brackets furnished by him conform to all the requirements and conditions of this specification. The Manufacture shall remedy, at no expense to the City of Ottawa or its agent, defects due to faulty workmanship, material or design for the period of one year after installation of the luminaires, but in no case for more than two years after receipt of the units by the City of Ottawa or its agent. 8.0 Instructions to Bidders 8.1 General Suppliers shall submit with their tenders the technical information requested herein. Suppliers who fail to provide the information requested might have their tenders rejected as incomplete. 8.2 Exceptions Where the tender is not in complete accordance with the requirements of this specification, the supplier shall submit a detailed list specifically outlining the exceptions or changes. If such a list is not provided, it will be understood that the supplier shall comply with all the requirements. 8.3 Modifications The supplier shall also submit a list of any changes in the design, components, construction or materials employed if the luminaires of the type being quoted differ from those previously approved by the City of Ottawa or its agent. Failure to notify the City of Ottawa or its agent of such changes when tendering may constitute sufficient reason to reject the tender. For Hydro Ottawa Use Only LLS0002 Rev.4 Page 7 of 9
8 8.4 Technical Information Requested Manufacturer's Reference a) Catalogue number of the luminaire b) Catalogue number and manufacturer of major components including ballast, starter, capacitor and refractor Photometric Performance a) Isocandela diagram b) Iso-lux (iso-foot candle) diagram and utilization data. c) Vertical candlepower distribution curve d) Luminaire maintenance factor (suggested by manufacturer) Mechanical Characteristics a) Dead weight b) Dimensions of luminaire, bracket and pole plate c) Effective projected area of luminaire and bracket combination d) Gasket/filter mechanisms for preventing dirt build-up on the lamp, reflector and glass lens e) The manufacturer shall so specify if he intends to make use of a flat prismatic glass lens to improve the photometric performance of the luminaire f) Types of finishes applied to various parts Electrical Characteristics and Performance (Rated Supply Voltage Assumed) a) Under open circuit condition, ballast input current and lamp voltage (OCV) b) Inrush current on striking of arc c) Normal or operating ballast input and lamp currents and maximum values of same d) Normal or operating ballast lamp voltage e) Variation in lamp wattage for rated supply voltage variation f) Ballast power factor g) Nominal ballast supply voltage h) Input watts and losses i) Rated life of ballast j) Ballast trapezoidal drawings Luminaire drawings and ballast schematic drawing Quality control program. Carried out by manufacturer including description of tests and sampling plan. 8.5 Samples Unless the luminaire being proposed has been previously approved by the City of Ottawa or its agent, the supplier shall provide a sample identical in every way to the units tendered. Samples will be returned to the supplier after evaluation. For Hydro Ottawa Use Only LLS0002 Rev.4 Page 8 of 9
9 9.0 Maintenance Parts Suppliers are requested to quote on the following maintenance parts or components: a) Ballast Kit including ballast, capacitor, starter, pre-wired with interconnecting wiring and mounting hardware as required by this specification b) Glass Lens, and c) Starter 10.0 Information Supplied To The Bidders The following minimum information will be supplied to the bidders when requesting a quotation: a) Quantity b) Lamp wattage c) Light distribution pattern, if other than as specified in Section 4.10 d) Input voltage of ballast, if other than as specified in specification LLS0005 e) Exterior colour of luminaire, if other than as specified in Section Drawings LLD0002, LLD0003, LLD0004, LLD0006, LLD0007, LLD0008. For Hydro Ottawa Use Only LLS0002 Rev.4 Page 9 of 9
CONSTRUCTION SPECIFICATION FOR THE INSTALLATION OF ROADWAY LUMINAIRES
ONTARIO PROVINCIAL STANDARD SPECIFICATION METRIC OPSS 617 SEPTEMBER 1984 CONSTRUCTION SPECIFICATION FOR THE INSTALLATION OF ROADWAY LUMINAIRES 617.01 SCOPE 617.02 REFERENCES 617.05 MATERIALS TABLE OF CONTENTS
More informationSTATE OF NEW JERSEY DEPARTMENT OF TRANSPORTATION TRENTON, NEW JERSEY SPECIFICATIONS FOR HIGH PRESSURE SODIUM LUMINAIRES HIGH MAST TYPE
STATE OF NEW JERSEY DEPARTMENT OF TRANSPORTATION TRENTON, NEW JERSEY 08625 SPECIFICATIONS FOR HIGH PRESSURE SODIUM LUMINAIRES HIGH MAST TYPE N.J. Specification No. Effective Date: July 1, 2001 New Jersey
More informationAFL FLOODLIGHT SERIES
AFL FLOODLIGHT SERIES A FL Flood Lighting for Hazardous Locations Class I, Division 2, Groups A, B, C & D UL 844 Hazardous Locations UL 598A Marine Outside Type Zone 2, Groups IIA, IIB & IIC CUL Cast Aluminum
More information220/230/240V Watt High Pressure Sodium - Hazardous Location Lighting - C1D2 - Pole Mount
220/230/240V Watt High Pressure Sodium - Hazardous Location Lighting - C1D2 - Pole Mount Part #: HAL-PRM-250W-HPS-220V-PT Page: 1 Made in the USA The efficient HAL-PRM-250W-HPS-220V-PT high pressure sodium
More informationTechnical Specification For Outdoor Substation Harmonic Filter Banks
Technical Specification For Outdoor Substation Harmonic Filter Banks One of Three 5th, 11th & 23rd, 34.5 kv, Rated Harmonic Filter Assemblies Provided for a Central Venezuela Heavy Oil Production Field
More informationAPPENDIX B: LISTS OF APPROVED MATERIALS
APPENDIX B: LISTS OF APPROVED MATERIALS APPENDIX B: LISTS OF APPROVED MATERIALS B1 Street Lighting MAY 2016 APPENDIX B1 STREETLIGHTING MATERIAL LIST 1.0 LIGHTING 1.1 Electrical Handholes CSA Precast concrete
More informationA. Three-phase, oil filled self-cooled, padmounted transformers are installed outdoors on pads in the EWEB distribution system.
1. APPLICATION A. Three-phase, oil filled self-cooled, padmounted transformers are installed outdoors on pads in the EWEB distribution system. 2. REFERENCE STANDARDS A. The transformers supplied shall
More informationKAD250MR3TBSPD04 Wall Fixture
8 South Street 796-76, TX Nacogdoches Phone: 96-69-79 Fax: 96-6-68 AllenWatson@elliottelectric.com MRTBSPD Wall Fixture Catalog Number MRTBSPD Manufacturer Description Area Light, Metal Halide Lamp; Lamp
More informationORDERING INFORMATION: 120 Volts (120) 208 Volts (208) 240 Volts (240) 277 Volts (277) 480 Volts (480)
Del Mar Corrosion resistant, Weather Tight Unit fabricated from spun Aluminum.080 Thick, Full Gasket Keeps out insects and Water. Lens & Removable Door Assembly: Hinged Door Assembly Formed from One Piece
More informationCEC: Class I, Division 1 and 2, Groups B, C, D Class II, Division 1 and 2, Groups E, F, G Class III Type 4X Exd IIB + H 2
Integrally Ballasted. 50 W, 70 W, 00 W, 50 W HPS; 75 W PSMH. 75 W MH. Medium Base. For Use with Threaded Metal Conduit. Applications For use in chemical and petrochemical plants, such as manufacturers
More informationLighting: Explosionproof Area HID. Applications. Standard Materials
Code Master Jr. HID Factory Sealed Luminaires Integrally Ballasted. 50 W, 70 W, 00 W, 50 W HPS; 50 W, 70 W, 00 W, 75 W PSMH. 75 W MH V. Medium Base. For Use with Threaded Metal Conduit. Class I, Division
More informationApplications. Standard Materials
Code Master Jr. HID Factory Sealed Luminaires Integrally Ballasted. 50 W, 70 W, 00 W, 50 W HPS; 50 W, 70 W, 00 W, 75 W PSMH. 75 W MH V. Medium Base. For Use with Threaded Metal Conduit. Class I, Division
More informationA2CO Series. Aktra II Cutoff Floodlight, W HID. Overall Dimensions. Specifications EPA Effective Projected Area.
Catalog Number: Approvals: - - - - - Series/Source-Wattage Optics Voltage Mounting Options Finish (Reflector) (Factory Installed) Overall Dimensions 16 (40.6 cm) 8.9 (22.5 cm) Weight (maximum) 20.5 (52.07
More informationLIGHTING: EXPLOSIONPROOF FLOODLIGHT. Applications. Options
Code Master 2 HID Factory Sealed Floodlights NEC: Class 1, Division 1 and 2, Groups C, D Marine Type Electric Fixtures Outside Type (Salt Water) CEC: V Class I, Division 1 and 2, Groups B, C, D Class II,
More informationPost Top Globes. ACL Large Acorn Post Top Globe Page 109. ACS Small Acorn Post Top Globe Page 109
s s ACS Small Acorn 109 ACL Large Acorn 109 AC3, AC5 Large Type 3 or 5 Acorn 109 BKS Small Buckeye 111 BKL Large Buckeye 111 BK3, BK5 Large Type 3 or 5 Buckeye 111 Small Chestnut 113 Large Chestnut 113
More informationHID/FLOODLIGHT: NEC/CEC EXPLOSIONPROOF. Applications. Options
Applications UL Listed for Outside Type (Salt Water). Ideal in Class I, Division 1 and 2 installations in refineries, in pipeline transportation facilities, at drilling rigs and in production facilities
More informationThree-Phase Pole Mounted Recloser
Three-Phase Pole Mounted Recloser Page 1 of 8 Table of Contents 1 GENERAL... 3 2 CONSTRUCTION... 3-5 3 BUSHINGS... 5 4 LINE CONNECTOR... 5 5 TOOLS....5 6 NAMEPLATES..6 7 PAINT... 6 8 EXTERNAL HARDWARE
More informationAreamaster 100 Wide-Beam Floodlights 70 W, 100 W, 150 W HPS; 70 W, 100 W, 150 PSMH For general, marine and hazardous locations.
Areamaster 100 Wide-Beam Floodlights NEC CEC V Class II, Divisions I and 2, Groups E, F, G V Class III Applications Highly efficient, all-weather flood-lighting for lower wattage service. Well suited for:
More informationMN/DOT Specification Light Emitting Diode (LED) Luminaire 03/20/2012
1. LISTING REQUIREMENTS MN/DOT Specification Light Emitting Diode (LED) Luminaire 03/20/2012 1.1. The Luminaire shall be listed by a National Recognized Testing Laboratory (NRTL) as defined by the U.S.
More information1000 Watt Metal Halide Flood Light - 110,000 Lumens - Slipfitter Mount - 120~277 Volts AC
1000 Watt Metal Halide Flood Light - 110,000 Lumens - Slipfitter Mount - 120~277 Volts AC Part #: MHFL-1000W Made in the USA The powerful and efficient MHFL-1000W metal halide light fixture from Larson
More informationCITY OF LOMPOC UTILITIES DEPARTMENT ELECTRICAL DIVISION SPECIFICATION NO. ELE-112 SUBSTATION CLASS VACUUM CIRCUIT BREAKERS OCTOBER 2008
CITY OF LOMPOC UTILITIES DEPARTMENT ELECTRICAL DIVISION SPECIFICATION NO. ELE-112 SUBSTATION CLASS VACUUM CIRCUIT BREAKERS OCTOBER 2008 SPECIFICATION NO: ELE_112_R1.doc Page 1 of 3 Rev. 10/28/2008 SPECIFICATION
More informationTABLE OF CONTENTS FOREWORD... 2 INTRODUCTION SCOPE NORMATIVE REFERENCES DEFINITIONS AND ABBREVIATIONS... 3
TITLE SPECIFICATION FOR MEDIUM VOLTAGE DATE: FEBRUARY 2015 PAGE: 1 OF 25 TABLE OF CONTENTS Page FOREWORD... 2 INTRODUCTION... 3 1 SCOPE... 3 2 NORMATIVE S... 3 3 DEFINITIONS AND ABBIATIONS... 3 4 REQUIREMENTS...
More informationAreamaster 1000 Floodlights Integrally Ballasted W HID For hazardous locations.
A, IIB, IIC Applications Powerful, efficient weatherproof lighting for large areas such as: Pulp and paper mills Processing plants Chemical plants Oil refineries Foundries Storage areas Waste and sewage
More informationSPECIFICATION FOR THREE-PHASE PAD MOUNT TRANSFORMERS. D. Dead Front, loop feed design shall be employed.
City of Cartersville Electric System P.O. Box 1390 320 S. Erwin St. Cartersville, GA 30120 770-387-5631 March 2006 SPECIFICATION FOR THREE-PHASE PAD MOUNT TRANSFORMERS This specification provides standardization
More informationHeight Finish Pole Options. Mounting Lamping Finish Voltage. Metal Halide. Single. H w H070 70w H w H w 15 1 /4" (387mm) 15 3 /4"
Vektor Project: Series Reflector Mounting Lamping Finish Voltage VE Vektor R Type II Aluminum Reflector Single R5 Type V Aluminum Reflector Double M Single ' Arm M Double ' Arm W Wall T Single Fitter Type:
More informationApplications. Standard Materials. Certifications and Compliances
Code Master 2 HID Factory Sealed Luminaires Class I, Division 1 and 2, Groups C, D Class I, Division 1 and 2, Groups B, C, D Applications Ideal for use in chemical and petrochemical plants, such as manufacturers
More informationTEXAS DEPARTMENT OF TRANSPORTATION GENERAL SERVICES DIVISION
TEXAS DEPARTMENT OF TRANSPORTATION GENERAL SERVICES DIVISION SPECIFICATION NO. AMENDED: NOVEMBER 2004** WARNING LIGHT SYSTEM, INCANDESCENT, LIGHTBAR PUBLICATION This specification is a product of the Texas
More informationHID/AREA: NEC/CEC EXPLOSIONPROOF. Applications. NEC/CEC Certifications and Compliances
Integrally Ballasted. 50 W, 70 W, 100 W, 150 W, 250 W, 400 W HPS; 175 W, 250 W, 320 W, 350 W, 400 W PSMH; 175 W, 250 W, 400 W MH. Applications Ideal for use in chemical and petrochemical plants, such as
More informationFIXED POWER FACTOR CORRECTION EQUIPMENT 5KV CLASS MEDIUM VOLTAGE SECTION Z
PART 1 GENERAL 1.01 1.02 1.03 1.04 1.05 SCOPE The Contractor shall furnish and install fixed power factor correction equipment as specified herein and as shown on the contract drawings. This specification
More information34-SDMS-02 SPECIFICATIONS FOR
SPECIFICATIONS FOR M V & L V FUSE LINKS This specification is property of SEC and subject to change or modification without any notice TABLE OF CONTENTS 1.0 SCOPE 3 2.0 CROSS REFERENCES 3 3.0 APPLICABLE
More information1000 Watt Metal Halide Light - Class 1 Division 2 Groups A-D - T3b Temperature - 110,000 lumens
1000 Watt Metal Halide Light - Class 1 Division 2 Groups A-D - T3b Temperature - 110,000 lumens Part #: HALPRM-1000WMH Made in the USA The extremely durable Larson Electronics HALPRM-1000WMH metal halide
More information56-SDMS-07 REV. 01 SPECIFICATIONS FOR
56-SDMS-07 REV. 01 SPECIFICATIONS FOR UNIT SUBSTATIONS UP TO 36 kv ALUMINUM TRANSFORMER ALUMINUM BUS BARS LVDP This specification is property of SEC and subject to change or modification without any notice
More informationOkSolar LED Outdoor Luminaires
OkSolar 488500 LED Outdoor Luminaires 1.0 PURPOSE The purpose of this specification is to provide the minimum performance requirements for the LED Outdoor Luminaire Fixture. This specification refers to
More informationApplications. Standard Materials. Certifications and Compliances
Code Master 2 HID Factory Sealed Luminaires NEC: Class I, Division 1 and 2, Groups C, D Class II, Division 1 and 2, Groups E, F, G Marine Type Electric Fixtures Outside Type (Salt Water) Class I, Division
More informationDECORATIVE. Tear Drop Series
DECORATIVE Tear Drop Series D ECORATIVE Product Catalog Tear Drop Series Styled to replicate the tear drop luminaires that illuminated boulevards during the first half of the century, the Holophane Tear
More informationOverall Dimensions. Specifications
Overall Dimensions EFI Mastfitter Mount (MA2) (standard) A 70-400W HID unit: 13 Housing A B C 13.3 11.3 23.3 (33.78cm) (28.70cm) (59.18cm) 750-1000W HID and 85-165W QL unit: 19 Housing A B C 19.4 14.9
More informationOverall Dimensions. Specifications
Overall Dimensions EFX B EFX VM Vertical Mount C 13 housing (70-400W) 19 housing (450-1000W) E D H B C D E 13.3 16.8 16.2 7.0 9.8 (33.78cm) (42.67cm) (41.15cm) (17.78cm) (24.89cm) F G H I J 22.2 11.3 6.3
More informationSeries Optics Mounting Lamping Finish Voltage. H039T6 1 39wT6 H w. H w. (T6 only available with MA and MS refractors) 12 3 /8" (314mm)
Project: Type: Qty: TC _ Series Optics Mounting Lamping Finish Voltage _ Options Series TC Triangular Column Optics Height Lamping Finish Voltage Options MA Type III MTR 5* Refractor MS Type V MTR 5* Refractor
More informationPredator Medium Floodlight Wet Location
Predator Medium Floodlight Wet Location Installation and Maintenance Manual AFTER INSTALLATION DELIVER THIS MANUAL TO OWNER IMPORTANT SAFETY INSTRUCTIONS -READ THESE INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING
More information34-SDMS-01 SPECIFICATIONS FOR
SPECIFICATIONS FOR M V DROPOUT FUSE CUT OUTS This specification is property of SEC and subject to change or modification without any notice CONTENTS C l a u s e s: Page No. 1- SCOPE 3 2- CROSS REFERENCES
More information43-SDMS-01 SPECIFICATIONS FOR
SPECIFICATIONS FOR MV SHUNT POWER CAPACITOR BANK UP TO 36 KV This specification is property of SEC and subject to change or modification without any notice CONTENTS Clause Description Page 1.0 SCOPE 3
More informationGavita HortiStar 600 SE EU
Pro line Gavita HortiStar 600 SE EU Horticultural design HortiStar 600 HR 96 reflector Reflector efficiency 96 % Easily replaceable reflector Shielded cord terminal For HPS/MH lamps up to 750 W Gavita
More informationSaturn Cutoff. Order Code: Pole Order Code: Series Height Finish Options. Customer: Date: Project: Qty: Type: SAC Saturn Cutoff SAC
Date: Customer: Project: Type: Qty: Saturn Cutoff Order Code: SAC - - - - - - - - SAC Series SAC Saturn Cutoff Pole Order Code: - - - Series Height Finish Options Optics R Type II Distribution R Type V
More informationDESCRIPTION Galleria's beauty and versatility make it an excellent choice for roadway and general area lighting applications. An aesthetic reveal in the formed aluminum housing gives the Galleria a distinctive
More informationCITY OF LOMPOC UTILITIES DEPARTMENT ELECTRICAL DIVISION SPECIFICATION NO. ELE-115
CITY OF LOMPOC UTILITIES DEPARTMENT ELECTRICAL DIVISION SPECIFICATION NO. ELE-115 PADMOUNTED TRANSFORMERS 12kV AND DUAL VOLTAGE, RADIAL FEED STAINLESS STEEL NOVEMBER 2011 Specification:ELE_115_R1 Page
More informationApplications. Straight Stanchion-Mount Fixture with Prismatic Glass Refractor and Guard. Pendant Mount Fixture with Prismatic Glass Refractor
Mercmaster III HID 50-250 Watt Luminaires Applications Enclosed and gasketed fixtures suitable for use in: Marine and wet locations A wide range of industrial, chemical processing and other areas where
More information4L EVM Hazard Gard H.I.D. Luminaires Mogul Base Factory Sealed (Groups C.D)
4L EVM Hazard Gard H.I.D. Luminaires Mogul Base Factory Sealed (Groups C.D) Cl. I, Div. 1 Groups B (GB suffix),c,d (with suffix GB), IIB IIA Paint Spray (100W max) Application: Hazard Gard luminaires are
More informationPGL350P W PS Wallpack
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 PGL350P1281 350W PS Wallpack Hubbell Lighting, Inc. Catalog Number Manufacturer Description Weight per unit Product Category
More informationMnDOT Specification Light Emitting Diode (LED) Luminaire For Roadway Lighting Asymmetrical High Mast 04/19/18
1. LISTING REQUIREMENTS MnDOT Specification Light Emitting Diode (LED) Luminaire For Roadway Lighting Asymmetrical High Mast 04/19/18 1.1. The luminaire shall be listed by a National Recognized Testing
More informationMATERIAL STANDARD ELECTRIC OPERATIONS ORGANIZATION. ****Supercedes BECo Standard E and ComElectric Spec ****
Page 1 of 8 ****Supercedes BECo Standard E2.12-2.14 and ComElectric Spec 7-0895**** THREE-PHASE DEADFRONT PAD-MOUNTED DISTRIBUTION TRANSFORMERS, LOOP & RADIAL FEED DESIGNS 1.0 General Requirements 1.1
More informationLighting Tables for New Equipment 7/16/2008
T8 and SUPER T8 Fluorescent Lamps and Fixtures with Electronic Ballasts LENGTH 2' F17T8 1 18 200 9.00 --- --- 2 32 201 9.00 --- --- 3 48 202 15.00 --- --- 4 57 203 15.00 --- --- F17T8 with Reflectors 1
More informationLED 2/3/4ft T8 Tube 120V
E-T8-1200-YR LED 2/3/4ft T8 Tube 120 Our LED Tubes utilize the latest LED chips as the light source, whilst using the standard T8 end caps, which makes it easy to install and replace traditional fluorescent
More informationR. STAHL Schaltgeräte GmbH Geschäftsbereich Leuchten Nordstraße Weimar, Germany
, INC. ECOLUX 6600 Series 6600/5 Explosion Protected Fluorescent Light Fixtures for Hazardous and Corrosive Applications Please read this entire document before beginning any work. 1. Safety Instructions
More informationStandard Grade 14 Inch Reflector. Ordering Information
Job Type Dimensions Specifications B A NRTL/C C Damp Location D E Slick- On Quick- On F A B C D E F 9-1/2" 2" 9-1/2" 20-22/32 24-27/32" 9-7/16" 14-1/4" 241 mm 51 mm 241 mm 536-631 mm 240 mm 362 mm 9-1/2"
More informationCD20S2 DENVER. Luminaire. Optics. Sources Lamp 4K = High power LED, 4000K (neutral white) ±150K.
Round shape. Formed aluminum housing with a cast aluminum side arm. Cast aluminum lens module. : Clear tempered glass lens, 98% transmissive. : Clear tempered glass lens, 91% transmissive. Tool-free opening
More informationSXPJ SERIES S X. HID & Compact Fluorescent Lighting for Hazardous and Hostile Locations
SXPJ SERIES HID & Compact Fluorescent Lighting for Hazardous and Hostile Locations S X PJ Class I, Division 1, Group C & D Class II, Division 1, Groups E, F & G Class III Zone 1, Groups IIA & IIB Factory
More informationPrismpack V, Prismalume V, Large Prismpack, Large Prismalume
AFTER INSTALLATION DELIVER THIS MANUAL TO OWNER Holophane Company Inc. Field Service Department IMPORTANT SAFETY INSTRUCTIONS -READ THESE INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING TO INSTALL OR MAINTAIN
More informationTechnical Specifications
LT Distribution Box Technical Specifications 1. SCOPE 1.1 This specification covers design, manufacture, testing at manufacturer works before dispatch and supply of L.T. Distribution Cabinet suitable for
More informationWPP25 250W MP Wal-Pak Borosilicate Glass Hinged/Removabl
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 WPP25 250W MP Wal-Pak Borosilicate Glass Hinged/Removabl Catalog Number Manufacturer Description Weight per unit Product
More informationشركة كهرباء محافظة القدس المساهمة المحدودة
Our Ref: Date: Messrs. Dear Sir, Tender 22/2017 (re-bidding) 11& 33Kv Fuse Cutouts and Links You are kindly requested to bid for supply and delivery (DDP) for the medium voltage overhead line accessories
More informationPole Series. Series Reflector Lens Mounting Lamping Finish Voltage. S w S w S w S w
Type: Qty: QHO Series Reflector Lens Mounting Lamping Finish Voltage QHO Quadro HO R Type II Aluminum reflector R5 Type V Aluminum reflector L S Project: Flat Glass Sagged Glass Series Reflector Lens Mounting
More informationA R C H I T E C T U R A L LO W L E V E L F LO O D L I G H T S E R I E S
T A B L E O F C O N T E N T S A R C H I T E C T U R A L LO W L E V E L F LO O D L I G H T S E R I E S LLF755 - Low Level Flood with Anti-Glare Faceplate C1.1 LLF800 - Low Level Flood with Anti-Glare Faceplate
More informationSXPJ SERIES S X azz.com/rigalite
SXPJ SERIES HID Lighting & Compact for Explosion Fluorescent Proof, Lighting Hazardous for and Hazardous Hostile Locations and Hostile Locations S X PJ Class I, Division 1, Group C & D Class II, Division
More informationAerolumeTM. Collection. Area Luminaires 3 Fixture Sizes W HID 64/80/120
Aerolume Collection Area Luminaires Fixture Sizes 70-00W HID 64/80/ Overview Mini-Aerolume Aerolume Aerolume-G 1." (4.9mm) 18" (47.mm) " (84.mm) 6." (16.1mm) 19" (48.6mm) 4" (1.4mm) 8" (0.mm) " (84.mm)
More informationCENTER BREAK GROUP OPERATED AIR BREAK SWITCHES RATED 15.5kV THROUGH 170kV EFFECTIVE DATE: 10/25/16 REV B
CENTER BREAK GROUP OPERATED AIR BREAK SWITCHES RATED 15.5kV THROUGH 170kV EFFECTIVE DATE: 10/25/16 REV B TCV2 Hubbell has a policy of continuous product improvement. Please visit hubbellpowersystems.com
More informationTechnical Specification for Pole Mounted Capacitor Rack
Technical Specification for Pole Mounted Rack Page 1 1. Scope and Function a) Pole mounted capacitor racks shall be installed on a distribution feed as an economical means of applying capacitor units to
More informationSTATE OF NEW JERSEY DEPARTMENT OF TRANSPORTATION TRENTON, NEW JERSEY 08625
STATE OF NEW JERSEY DEPARTMENT OF TRANSPORTATION TRENTON, NEW JERSEY 08625 SPECIFICATIONS FOR A 19 INCH RACK BASE MOUNT (HEATER/AC) (ENVIRONMENTAL FIELD TERMINAL CABINET) N. J. Specification No. Effective
More informationG1-24. Applications UL listed for marine type electric fixtures--outside. Ideal in Class I, Div. 1 and 2 installations
1-24 Applications UL listed for marine type electric fixtures--outside type (salt water). Ideal in Class I, Div. 1 and 2 installations in refineries, pipeline transportation facilities; at drilling rigs
More informationMATERIAL SPECIFICATION ELECTRIC OPERATIONS ORGANIZATION. M3902 ****Supercedes BECo Standard E and ComElectric Spec ****
Page 1 of 8 ****Supercedes BECo Standard E2.12-2.12 and ComElectric Spec 6-0895**** 1.0 General Requirements SINGLE PHASE PAD-MOUNTED DISTRIBUTION TRANSFORMERS 1.1 These specifications cover single-phase
More informationR. STAHL Schaltgeräte GmbH Geschäftsbereich Leuchten Nordstraße Weimar, Germany
ECOLUX 6608 Series 6608/5 Explosion Protected Fluorescent Emergency Light Fixtures for Hazardous and Corrosive Applications Please read this entire document before beginning any work. 1. Safety Instructions
More informationIMPORTANT SAFETY INSTRUCTIONS
IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION To reduce the risk of death, personal injury or property damage from
More informationSOURCE TE- Electronic MH. OPTIONS See Below OPTIONS. L = Lamped BLANK = General Purpose Optics A = Asymmetric Optics S = Spot
CATALOG NO. TYPE NO. JOB NAME -8 GP Flood Series Floodlighting GP (Mini) ORDERING INFORMATION Catalog Number: Example: GPA070TEL GP A TE SERIES GP-General Purpose Flood SIZE -Mini ACCESSORIES GPGS = Visor
More information1000W and 2000W versions
503 FLOODLIGHT 126 600W HPS 1000W and 2000W versions The 503 is a high powered floodlight with a wide ambient temperature range. The high upper ambient and corrosion resistant aluminium constriction, make
More informationOP2 CosmoPolis Series
Catalog Number: Approvals: - - - - - Series/Source-Wattage Optics E ballast Voltage Mounting Options Finish (Factory Installed) Accessories (Field Installed) Date: Page of 6 Overall Dimensions OP2 arm
More informationAPPENDIX B SPECIFICATION FOR GENERATOR OVERHAUL EMD MODEL AR10 D18... B-1
Table of Contents APPENDIX B SPECIFICATION FOR GENERATOR OVERHAUL EMD MODEL AR10 D18... B-1 B.01 SCOPE... B-1 B.02 GENERAL... B-1 B.03 ELECTRICAL QUALIFICATION... B-1 B.04 EQUIPMENT RECONDITIONING... B-2
More informationTORNADOTM BOLLARD PATENTS PENDING
TORNADOTM BOLLARD PATENTS PENDING Day Tornado Bollard Unlike any bollard available in today s specification pallet, Tornado offers a new form and character for pedestrian scale lighting. Tornado adds an
More informationWELLGLASS EV.. Series - H.I.D. well glass lighting fixture. Aluminium with low content of copper. O-ring made of Nitrile Rubber (NBR)
WELLGLASS EV.. Series - H.I.D. well glass lighting fixture EV.. series well glass lighting fixtures are suitable for hazardous areas of industrial plants for lighting of indoor and outdoor structures,
More information. Tighten loose screws and bolts; replace if
BELL SYSTEM PRACTICES Station Operations Manual Coin Stations SECTIONC39.708 Issue 2, January, 1959 AT&TCoStandard BOOTHS- OUTDOOR KS-14611 AND NO.9 MAINTENANCE 1.00 BOOTH CHECK POINTS. Safe approach to
More informationORDERING INFORMATION: 120 Volts (120)
Bull38 A weather tight unit fabricated from durable grade die-cast aluminum & fully sealed, gasketed glass lens. Mount: 1/2 threaded adjustable knuckle mount Porcelain medium base socket Thermoset polyester
More informationTRINETICS CSD SERIES OIL SWITCH INSTALLATION INSTRUCTIONS
TRINETICS CSD SERIES OIL SWITCH INSTALLATION INSTRUCTIONS 33220900 DECEMBER 2011 Caution: The equipment covered by these installation instructions should be installed and serviced only by properly trained
More informationPerimaliter Wallpacks
Perimaliter Wallpacks Perimaliter III PVL3 / PGM3 Perimaliter II PGL Solutions for Perimeter/Area Lighting Perimaliter Wallpacks The Perimaliter wallpack has been the design leader in refractor wallpacks
More informationPublication No.: PSG
TABLE OF CONTENTS PAGE 1.0 SCOPE...2 2.0 STANDARDS...2 3.0 DESIGN REQUIREMENTS...2 3.01 Service Conditions... 2 3.02 Ratings... 3 3.03 Resistors... 3 3.04 Interrupter... 4 3.05 SF 6 Gas System... 4 3.06
More informationProduct Specifications for Phase Over Phase GOABS(r)
1. General a) This specification covers the design, manufacture, and shipment of phase-over-phase, 1-way, 2-way, 3-way, and 4-way, gang-operated disconnecting switches, both air-break and load-break, for
More information.3 Section Waste Management and Disposal.
Issued 2005/06/01 Section 16261 Uninterruptible Power Systems Static Page 1 of 10 PART 1 GENERAL 1.1 RELATED SECTIONS.1 Section 01330 Submittal Procedures..2 Section 01780 Closeout Submittals..3 Section
More information31-SDMS-02 REV. 01 SPECIFICATIONS FOR
31-SDMS-02 REV. 01 SPECIFICATIONS FOR LOW VOLTAGE DISTRIBUTION PILLAR This specification is property of SEC and subject to change or modification without any notice C O N T E N T S S. NO. D E S C R I P
More informationINDEX PAGE WHERE LIGHT CREATES COLOUR SERIES, EDITION 01
INDEX PAGE WHERE LIGHT CREATES COLOUR SERIES, EDITION 01 Page LED Roadway Lighting Atlas Basic LED Roadway...1-2 ROADWAY LIGHTING Atlas LED Roadway...3-4 Atlas Evo LED Roadway I...5-6 Atlas Evo LED Roadway
More information31-SDMS-01 REV. 03 SPECIFICATIONS FOR
31-SDMS-01 REV. 03 SPECIFICATIONS FOR LOW VOLTAGE DISTRIBUTION PANEL This specification is property of SEC and subject to change or modification without any notice CONTENTS Clauses: Page No. 1.0 SCOPE
More informationCode Master Incandescent Factory Sealed Luminaires Explosionproof, Dust-Ignitionproof For use with threaded metal conduit.
Applications For use in hazardous locations such as plants where plastics, paints, thinners and petrochemicals are manufactured. For use in chemical and petrochemical plants, such as manufacturers of plastics,
More informationDoc Ref: WD030/2/11/12 Fern-Howard Ltd. 2 Newman Lane, Alton, Hampshire, GU34 2QR. Reg. No
The Micro-Max is the smaller version of the Mini-Max, retaining the market leading features of the larger model. A prismatic diffuser gives an even light distribution from the energy efficient 2D lamp.
More informationCALLISTO SERIES. Product Overview and Technical information>>
CALLISTO SERIES Product Overview and Technical information>> luminaire > CAL2 CALM CAL CAL1 CAL2 CALLISTO SERIES Helping shape a new era / Inspired by classical and contemporary elements, the Callisto
More informationExceLine 1611 Clovis R. Barker Road San Marcos, TX Fax: PT#: EXSP072A0812
Type No. Catalog No. Job. Name WL Series APPLICATIONS Applications include low ceiling applications, light industrial manufacturing facilities, offices, lobbies, conference rooms, food processing plants,
More informationACCESSORIES - Electronic Daylight Switch - Cadmium Sulphide Daylight Switch Accessories 8.1 8.1 8.2 Daylight Switch Daylight Switch Daylight Switch D2 Wire-In PBL s 8.2 8.2 8.2 Docklite Docklite Light
More informationLIGHTING SPECIFICATIONS
Incentives: Specifications LIGHTING SPECIFICATIONS All lighting projects are expected to comply with the Illuminating Engineering Society of North America (IESNA) recommended lighting levels or the local
More informationAEROSYSTEM POLE AND BRACKET SPECIFICATIONS NO PAIN, ALL GAIN ORDERING CHART FINISHES. by LSI Courtsider Sports Lighting. Installation As Easy As 1 2 3
POLE AND BRACKET SPECIFICATIONS NO PAIN, ALL GAIN 3' The Aerosystem s modular assembly process is simple genius. The components of the system have been designed to be easy to install, easy to handle, and
More informationfirst issue : last change : MSD Platinum 15 R number of pages : 12 LE 2166
first issue : 2011-02-07 S FOR MSD Platinum LAMP SYSTEMS last change : 2013-01-11. MSD Platinum 15 R 9281 916 05300 number of pages : 12 Philips Innovative Applications N.V. Specifications subject to change
More information2000 Watt Telescoping Light Mast - 30' 3-Stage Light Tower Rotating Boom - High Mast Lighting
2000 Watt Telescoping Light Mast - 30' 3-Stage Light Tower - 360 Rotating Boom - High Mast Lighting Part #: LM-30-3S-2X1000W Page: 1 Made in the USA The LM-30-3S-2X100W Metal Halide Light Tower from Larson
More informationMercmaster II HID Luminaires High Pressure Sodium and Pulse Start Metal Halide. Mogul Base UNILETS for Use with Threaded Metal Conduit.
UNILETS for Use with Threaded Metal Conduit. Applications Enclosed and gasketed HID lighting fixtures for use in tunnels, walkways, bridges, storage facilities, processing plants, parking lots, foundries,
More informationSpecification Guide. for RMVAC. Direct Replacement. AC Medium Voltage. Circuit Breakers
Specification Guide for RMVAC Direct Replacement AC Medium Voltage Circuit Breakers Table of Contents 1.0 General Work Scope... 3 2.0 Standards... 3 3.0 Supplier Qualifications... 4 4.0 Circuit Breaker
More informationNema Head We light your world
Nema Head We light your world 03.15.18 THD 80 PF >.95 10kV Surge Protector + 5-40 C~50 C 35,000 Warranty YEAR LED Nema Head 44w/65w Advances in LED technology allow us to create
More informationTEMPORARY ELECTRIC WIRING FOR CARNIVALS, CONVENTIONS, EXHIBITIONS, FAIRS AND SIMILAR USES
INFORMATION BULLETIN / PUBLIC - ELECTRICAL CODE REFERENCE NO.: LAMC 93.0230 Effective: 3-24-69 DOCUMENT NO. P/EC 2002-006 Revised: 11-17-00 Previously Issued As: RGA #7-69 TEMPORARY ELECTRIC WIRING FOR