Bulletin 150 SMC Flex Smart Motor Controllers Product Overview/Modes of Operation/Features

Size: px
Start display at page:

Download "Bulletin 150 SMC Flex Smart Motor Controllers Product Overview/Modes of Operation/Features"

Transcription

1 Bulletin Product Overview/Modes of Operation/Features Bulletin SMC Flex Smart Motor Controller The SMC Flex controller provides microprocessor controlled starting for standard -phase squirrel-cage induction or Wye-Delta (-lead) motors. Seven standard modes of operation are available within a single controller. A Range Seven Standard Start Modes Options Include Pump Control and Braking Control Features Built in SCR Bypass/Run Contactor Built in Electronic Motor Overload Protection CT on each Phase Metering Standards Compliance UL CSA C. No. EN/IEC - EN/IEC -- Modes of Operation The SMC Flex controller provides the following modes of operation as standard: Soft Start Full Voltage Start Selectable Kickstart Linear Speed Acceleration Current Limit Start Preset Slow Speed Dual Ramp Start Soft Stop DPI Communication LCD Display Keypad Programming Four Programmable Auxiliary Contacts The SMC Flex controller is available for motors rated A; V AC, V AC, or V AC, / Hz. In addition to motors, the SMC Flex controller can be used to control resistive loads. Table of Contents Features... this page Explanation - Product Selection... - Options... - Accessories... - Specifications... - Approx. Dims This catalog product information is based on the minimum information needed to select an SMC soft starter for applications with low starting torque requirements. For product selection involving loads with high starting torque requirements (large fan, rock crusher, chipper, etc.), use of the free tools available from the Rockwell Automation Website is recommended: Note: For detailed information about the different modes of operation, see page -. Certifications culus Listed (Open Type) (File No. E, Guides NMFT, NMFT) CSA Certified (File No. LR ) CE Marked CCC Certified Optional Modes of Operation Pump Control Start and Stop Braking Control SMB Smart Motor Braking Slow Speed with Braking Accu-Stop of Features Electronic Motor Overload Protection The SMC Flex controller incorporates, as standard, electronic motor overload protection. This overload protection is accomplished electronically with an It algorithm. When coordinated with the proper short-circuit protection, overload protection is intended to protect the motor, motor controller, and power wiring against overheating caused by excessive overcurrent. The SMC Flex controller meets applicable requirements as a motor overload protective device. The controller s overload protection is programmable, providing the user with flexibility. The overload trip class consists of either OFF,,,, or protection. The trip current is programmed by entering the motor full-load current rating, service factor, and selecting the trip class. Thermal memory is included to accurately model motor operating temperature. Ambient temperature insensitivity is inherent in the electronic design of the overload. Undervoltage Protection The SMC Flex controller s undervoltage protection will halt motor operation if a drop in the incoming line voltage is detected. The undervoltage trip level is adjustable as a percentage of the programmed line voltage, from %. To eliminate nuisance trips, a programmable undervoltage trip delay time of seconds can also be programmed. The line voltage must remain below the undervoltage trip level during the programmed delay time. Overvoltage Protection If a rise in the incoming line voltage is detected, the SMC Flex controller s overvoltage protection will halt motor operation. The overvoltage trip level is adjustable as a percentage of the programmed line voltage, from %. To eliminate nuisance trips, a programmable overvoltage trip delay time of seconds can also be programmed. The line voltage must remain above the overvoltage trip level during the programmed delay time. - Publication A-CAA-EN-P

2 Stall Protection and Jam Detection Motors can experience locked-rotor currents and develop high torque levels in the event of a stall or a jam. These conditions can result in winding insulation breakdown or mechanical damage to the connected load. The SMC Flex controller provides both stall protection and jam detection for enhanced motor and system protection. Stall protection allows the user to program a maximum stall protection delay time from seconds. The stall protection delay time is in addition to the programmed start time and begins only after the start time has timed out. If the controller senses that the motor is stalled, it will shut down after the delay period has expired. Jam detection allows the user to determine the motor jam detection level as a percentage of the motor s full-load current rating. To prevent nuisance tripping, a jam detection delay time, from.. seconds, can be programmed. This allows the user to select the time delay required before the SMC Flex controller will trip on a motor jam condition. The motor current must remain above the jam detection level during the delay time. Jam detection is active only after the motor has reached full speed. Underload Protection Utilizing the underload protection of the SMC Flex controller, motor operation can be halted if a drop in current is sensed. The SMC Flex controller provides an adjustable underload trip setting from % of the programmed motor full-load current rating with an adjustable trip delay time of seconds. Voltage Unbalance Protection Voltage unbalance is detected by monitoring the -phase supply voltage magnitudes in conjunction with the rotational relationship of the three phases. The controller will halt motor operation when the calculated voltage unbalance reaches the user-programmed trip level. The voltage unbalance trip level is programmable from % unbalance. Excessive Starts Per Hour The SMC Flex controller allows the user to program the allowed number of starts per hour (up to ). This helps eliminate motor stress caused by repeated starting during a short time period. Metering Power monitoring parameters include: -phase current Power Factor -phase voltage Motor thermal capacity usage Power in kw or mw Elapsed time Power usage in kwh or mwh Note: The motor thermal capacity usage allows the user to monitor the amount of overload thermal capacity usage before the SMC Flex controller s built-in electronic overload trips. Built-in DPI Communication Capabilities A serial interface port is provided as standard, which allows connection to a Bulletin Human Interface Module and a variety of Bulletin -COMM Communication Modules. This includes Allen- Bradley Remote I/O, DeviceNet, ControlNet, Ethernet, ProfiBUS, Interbus, and RS-DF. LCD Display The SMC Flex controller s three-line -character backlit LCD display provides parameter identification using clear, informative text. Controller set up can be performed quickly and easily without the use of a reference manual. Parameters are arranged in an organized four-level menu structure for ease of programming and fast access to parameters. Network I/O The SMC Flex can have up to two inputs and four outputs controlled via a communication network. The output contacts use the auxiliary contacts. Bulletin Features Keypad Programming Programming of parameters is accomplished through a five-button keypad on the front of the SMC Flex controller. The five buttons include up and down arrows, an Enter button, a Select button, and an Escape button. The user needs only to enter the correct sequence of keystrokes for programming the SMC Flex controller. Auxiliary Contacts Four fully programmable hard contacts are furnished as standard with the SMC Flex controller: Aux #, Aux #, Aux #, Aux # N.O./N.C. Normal/Up-to-Speed/External Bypass/Fault/Alarm/Network Ground Fault Input The SMC Flex can monitor for ground fault conditions. An external core balance current transformer is required for this function. See SMC Flex User Manual for additional information. Tach Input A motor tachometer is required for the Linear Speed Start mode. Please see the Specifications section on page - for tachometer characteristics. PTC Input A motor PTC input can be monitored by the SMC Flex. In the event of a fault, the SMC Flex will shut down and indicate a motor PTC fault. Publication A-CAA-EN-P -

3 Bulletin Catalog Number Explanation Open and Non-Combination F F B D B L a Bulletin Number Solid-State Controller B F F F F F F F F F F F F F F F F Combination H B H B F F F F F F F F F F F F F F Enclosed Solid-State Controller with Isolation Contactor b Controller Ratings A, V AC A, V AC A, V AC A, V AC A, V AC A, V AC A, V AC A, V AC A, V AC A, V AC A, V AC A, V AC A, V AC A, V AC A, V AC A, V AC a Bulletin Number Solid-State Controller with Fusible Disconnect Solid-State Controller with Fusible Disconnect and Isolation Contactor Solid-State Controller with Circuit Breaker Solid-State Controller with Circuit Breaker and Isolation Contactor b Controller Ratings A, V AC A, V AC A, V AC A, V AC A, V AC A, V AC A, V AC A, V AC A, V AC A, V AC A, V AC A, V AC A, V AC A, V AC a b c d e f g c F J N B C Z H A B C Enclosure Type NEMA Type / (IP) (Non-Combination Only) NEMA Type (IP) d Open Input Line Voltage Open Type V AC, -phase, and Hz V AC, -phase, and Hz V AC, -phase, and Hz (Open Only, A and above) Non-Combination Enclosed Only V AC, -phase, and Hz V AC, -phase, and Hz V AC, -phase, and Hz V AC, -phase, and Hz D R E A Blank B D H F F BD B B a b c d e f g c F J HD AD BD CD Cat. No. Enclosure Type NEMA Type / (IP) NEMA Type (IP) d Line Voltage, V AC Control Voltage V AC, -phase, and Hz V AC, -phase, and Hz V AC, -phase, and Hz V AC, -phase, and Hz Hp Rating Cat. No. Hp Rating Cat. No. f Horsepower L M B e Control Voltage V AC ( A units) V AC/DC ( A units) (Open Only) /V AC ( A units) /V AC ( A units) f Options (Select Only One) Standard Pump Control Braking Control g Options (Non-Combination only) (see page - for a full listing) Line-Mounted Protective Module (enclosed only) Load-Mounted Protective Module (enclosed only) Line- and Load-Mounted Protective Modules (enclosed only) Load-side MOVs are not available with Pump and Braking options, or on delta-connected motors. MOVs can be field installed for open type units. Blank B D L M B Hp Rating e Control Options Standard Pump Control Braking Control g Options (see page - for a full listing) Line-Mounted Protective Module Load-Mounted Protective Module Line- and Load-Mounted Protective Modules Load-side MOVs are not available with Pump and Braking options, or when used with insidethe-delta connections. Cat. No. Hp Rating Cat. No. Hp Rating Publication A-CAA-EN-P

4 Bulletin Product Selection Open Type and Non-Combination Enclosed (IP, Type /) Controllers For use with Line-Connected Motors Enclosures other than those listed are available; consult your local Rockwell Automation sales office or Allen-Bradley distributor. Rated Voltage [V AC] / Motor Current [A] Max. kw, Hz Max. Hp, Hz Control Power Open Type Line-Connected Motors IP (Type /) Enclosed Non-Combination Controllers -FNBD -FFHD -FNBR -FNBD -FFHD -FNBR -FNBD -FFHD -FNBR -FNBD -FFHD -FNBR -FNBD -FFHD -FNBR -FNBD -FFHD -FNBR -FNBD -FFHD -FNBR -FNBD -FFHD -FNBR -FNBD -FFHD -FNBR -FNBD -FFHD -FNBR -FNBD -FFHD -FNBR -FNBD -FFHD -FNBR /V AC, / Hz -FNBE -FJHE /V AC, / Hz -FNBA -FJHA /V AC, / Hz -FNBE -FJHE /V AC, / Hz -FNBA -FJHA /V AC, / Hz -FNBE /V AC, / Hz -FNBA /V AC, / Hz -FNBE /V AC, / Hz -FNBA Controllers rated A and greater are not equipped with line and load terminal lugs. See page - for terminal lug kits. Motor FLA rating should fall within specified current range for unit to operate properly. Special consideration should be given when using a motor with a potentially high starting current (greater than ten times motor FLA) with the SMC Flex in the "Full Voltage" starting mode. Contact Rockwell Automation technical support for further guidance. These controllers require a separate V, / Hz single-phase control source. To add a control circuit transformer to the enclosure, add the appropriate option code to the catalog string. Separate V or V single-phase power supply is required for fan operation. Line and load termination are provided as standard. Available in IP (Type ) enclosure only. Publication A-CAA-EN-P -

5 Bulletin Product Selection Open Type and Non-Combination Enclosed (IP, Type /) Controllers For use with Line-Connected Motors, Continued Enclosures other than those listed are available; consult your local Rockwell Automation sales office or Allen-Bradley distributor. Rated Voltage [V AC] Motor Current [A] Max. kw, Hz Max. Hp, Hz Control Power Open Type Line-Connected Motors IP (Type /) Enclosed Non-Combination Controllers -FNBD -FFAD -FNBR -FNBD -FFAD -FNBR -FNBD -FFAD -FNBR -FNBD -FFAD -FNBR -FNBD -FFAD -FNBR -FNBD -FFAD -FNBR -FNBD -FFAD -FNBR -FNBD -FFAD -FNBR -FNBD -FFAD -FNBR -FNBD -FFAD -FNBR -FNBD -FFAD -FNBR -FNBD -FFAD -FNBR /V AC, / Hz -FNBE -FJAE /V AC, / Hz -FNBA -FJAA /V AC, / Hz -FNBE -FJAE /V AC, / Hz -FNBA -FJAA /V AC, / Hz -FNBE /V AC, / Hz -FNBA /V AC, / Hz -FNBE /V AC, / Hz -FNBA Controllers rated A and greater are not equipped with line and load terminal lugs. See page - for terminal lug kits. Motor FLA rating should fall within specified current range for unit to operate properly. Special consideration should be given when using a motor with a potentially high starting current (greater than ten times motor FLA) with the SMC Flex in the "Full Voltage" starting mode. Contact Rockwell Automation technical support for further guidance. These controllers require a separate V, / Hz single-phase control source. To add a control circuit transformer to the enclosure, add the appropriate option code to the catalog string. Separate V or V single-phase power supply is required for fan operation. Line and load termination are provided as standard. Available in IP (Type ) enclosure only. - Publication A-CAA-EN-P

6 Bulletin Product Selection Open Type and Non-Combination Enclosed (IP, Type /) Controllers For use with Line-Connected Motors, Continued Enclosures other than those listed are available; consult your local Rockwell Automation sales office or Allen-Bradley distributor. Rated Voltage [V AC] // Motor Current [A] Max. kw, Hz Max. Hp, Hz Control Power Open Type Line-Connected Motors IP (Type /) Enclosed Non-Combination Controllers -FNBD -FFBD -FNBR -FNBD -FFBD -FNBR -FNBD -FFBD -FNBR -FNBD -FFBD -FNBR -FNBD -FFBD -FNBR -FNBD -FFBD -FNBR -FNBD -FFBD -FNBR -FNBD -FFBD -FNBR -FNBD -FFBD -FNBR -FNBD -FFBD -FNBR -FNBD -FFBD -FNBR -FNBD -FFBD -FNBR /V AC, / Hz -FNBE -FJBE /V AC, / Hz -FNBA -FJBA /V AC, / Hz -FNBE -FJBE /V AC, / Hz -FNBA -FJBA /V AC, / Hz -FNBE /V AC, / Hz -FNBA /V AC, / Hz -FNBE /V AC, / Hz -FNBA Controllers rated A and greater are not equipped with line and load terminal lugs. See page - for terminal lug kits. Motor FLA rating should fall within specified current range for unit to operate properly. Special consideration should be given when using a motor with a potentially high starting current (greater than ten times motor FLA) with the SMC Flex in the "Full Voltage" starting mode. Contact Rockwell Automation technical support for further guidance. These controllers require a separate V, / Hz single-phase control source. To add a control circuit transformer to the enclosure, add the appropriate option code to the catalog string. Separate V or V single-phase power supply is required for fan operation. Line and load termination are provided as standard. Available in IP (Type ) enclosure only. Publication A-CAA-EN-P -

7 Bulletin Product Selection Open Type Controllers For use with Delta-Connected Motors Rated Voltage [V AC] Motor Current [A] Max. kw, Hz Max. Hp, Hz Control Power / Open Type -FNBD -FNBR -FNBD -FNBR -FNBD -FNBR -FNBD -FNBR -FNBD -FNBR -FNBD -FNBR -FNBD -FNBR -FNBD -FNBR -FNBD -FNBR -FNBD -FNBR -FNBD -FNBR -FNBD -FNBR /V AC, / Hz -FNBE /V AC, / Hz -FNBA /V AC, / Hz -FNBE /V AC, / Hz -FNBA /V AC, / Hz -FNBE /V AC, / Hz -FNBA /V AC, / Hz -FNBE /V AC, / Hz -FNBA Controllers rated A and greater are not equipped with line and load terminal lugs. See page - for terminal lug kits. Motor FLA rating should fall within specified current range for unit to operate properly. Special consideration should be given when using a motor with a potentially high starting current (greater than ten times motor FLA) with the SMC Flex in the "Full Voltage" starting mode. Contact Rockwell Automation technical support for further guidance. Separate V or V single-phase power supply is required for fan operation. Publication A-CAA-EN-P -

8 Bulletin Product Selection Open Type Controllers For use with Delta-Connected Motors, Continued Rated Voltage [V AC] Motor Current [A] Max. kw, Hz Max. Hp, Hz Control Power Open Type -FNBD -FNBR -FNBD -FNBR -FNBD -FNBR -FNBD -FNBR -FNBD -FNBR -FNBD -FNBR -FNBD -FNBR -FNBD -FNBR -FNBD -FNBR -FNBD -FNBR -FNBD -FNBR -FNBD -FNBR /V AC, / Hz -FNBE /V AC, / Hz -FNBA /V AC, / Hz -FNBE /V AC, / Hz -FNBA /V AC, / Hz -FNBE /V AC, / Hz -FNBA /V AC, / Hz -FNBE /V AC, / Hz -FNBA Controllers rated A and greater are not equipped with line and load terminal lugs. See page - for terminal lug kits. Motor FLA rating should fall within specified current range for unit to operate properly. Special consideration should be given when using a motor with a potentially high starting current (greater than ten times motor FLA) with the SMC Flex in the "Full Voltage" starting mode. Contact Rockwell Automation technical support for further guidance. Separate V or V single-phase power supply is required for fan operation. - Publication A-CAA-EN-P

9 Bulletin Product Selection Open Type Controllers For use with Delta-Connected Motors, Continued Rated Voltage [V AC] Motor Current [A] Max. kw, Hz Max. Hp, Hz Control Power // Open Type -FNBD -FNBR -FNBD -FNBR -FNBD -FNBR -FNBD -FNBR -FNBD -FNBR -FNBD -FNBR -FNBD -FNBR -FNBD -FNBR -FNBD -FNBR -FNBD -FNBR -FNBD -FNBR -FNBD -FNBR /V AC, / Hz -FNBE /V AC, / Hz -FNBA /V AC, / Hz -FNBE /V AC, / Hz -FNBA /V AC, / Hz -FNBE /V AC, / Hz -FNBA /V AC, / Hz -FNBE /V AC, / Hz -FNBA Controllers rated A and greater are not equipped with line and load terminal lugs. See page - for terminal lug kits. Motor FLA rating should fall within specified current range for unit to operate properly. Special consideration should be given when using a motor with a potentially high starting current (greater than ten times motor FLA) with the SMC Flex in the "Full Voltage" starting mode. Contact Rockwell Automation technical support for further guidance. Separate V or V single-phase power supply is required for fan operation. Publication A-CAA-EN-P -

10 Bulletin Modifications Control Options (open and enclosed) Option Modification Pump Control Provides smooth motor acceleration and deceleration, reducing surges caused by the starting and stopping of centrifugal pumps. Starting time is adjustable from s, and stopping time is adjustable from s. B Braking Control Provides Smart Motor Braking (SMB), Accu-Stop, and Slow Speed with Braking. D Enclosed Options Option Modification Start-Stop Push Button - Start-Stop Push Button with H-O-A Selector Switch -F Soft Stop Push Button XA Push Buttons Pump Stop Push Button XB Slow Speed Push Button XC Brake Push Button XD Accu-Stop/Slow Speed Push Button XE Selector Switch Hand-Off-Auto Selector Switch - SMC-Off-Bypass Selector Switch -B Transformer Pilot Light - Green Power On Indicator -G Pilot Lights Transformer Pilot Light - Red Run Indicator -R Push-to-Test Pilot Light - Red Run Indicator -R Control Circuit Transformer (fused primary and secondary) -P Additional VA Control Circuit Transformer (fused primary and secondary) -PX Control Circuit Transformer VA Control Circuit Transformer (fused primary and secondary) -PK VA Control Circuit Transformer (fused primary and secondary) -PL VA Control Circuit Transformer (fused primary and secondary) -PM V Line Side Protective Module V Line Side Protective Module -L Protective Modules V Load Side Protective Module V Load Side Protective Module -M V Both Line and Load Side Protective Modules V Both Line and Load Side Protective Modules -B Human Interface Module Door-mounted, Full Numeric (Type /) -HC RS- -S DeviceNet -D Communication Module Ethernet/IP -E Control Net -C ProfiBUS -P Disconnect Auxiliary N.O. disconnect auxiliary mounted on operating mechanism - N.C. disconnect auxiliary mounted on operating mechanism - Circuit Breaker Auxiliary Internal N.O. circuit breaker auxiliary -X Internal N.C. circuit breaker auxiliary -X Service Entrance Label Service Entrance Label -SEL Oil Pump Starter Bulletin NEMA Size starter and Bulletin solid-state overload -OPS Add the designated letter to the end of the cat. no. Example: To add the Pump Control option: -FNBDB or H-FFBDB-. Option push buttons are available only when the corresponding option module is selected. Example: -FFBDB-XB. Bypass contactor and overload are not included with this option. A -NB or -BP needs to be added to the catalog string to add these devices. Publication A-CAA-EN-P -

11 Bulletin Modifications/Accessories Enclosed Options, Continued Option NEMA Bypass Contactor and Overload Relay NEMA Isolation Contactor MCS Bypass Contactor and Overload Relay A A A A A A A A A A A A A A A A A A Modification -NB -NI -BP Accessories Protective Modules Protective modules must not be placed on the load side of a device when using an inside-the-delta connection or with Pump, Braking, or Linerar Speed control. Current Rating [A] Field Modification -F V Protective Module -FL -F V Protective Module -FL The same protective module mounts on the line or load side of the SMC Flex. For applications requiring both line and load side protection, two protective modules must be ordered. Terminal Lug Kits ( A) Current Rating [A] Total No. of Line Controller Terminal Lugs Possible Each Side Wire Size Line Side Load Side Pkg. Qty. # MCM AWG mm mm -LF # MCM AWG mm mm -LG / MCM AWG -DL / MCM AWG -DL / MCM AWG -DL / MCM AWG -DL Line and Load terminals are provided as standard on enclosed SMCs. A units have box lugs standard. No additional lugs are required. The A device requires () -DL and () -DL per connection. When a multi-conductor lug is required, refer to the User Manual for appropriate lug catalog number. - Publication A-CAA-EN-P

12 Bulletin Accessories IEC Terminal Covers IEC line or load terminal covers for and A devices. Dead front protection IEC line or load terminal covers for A devices. Dead front protection IEC line or load terminal covers for A devices. Dead front protection A units have terminal guards standard. No additional terminal guards are required. Package Quantity Field Modification -TC -TC -TC Human Interface and Communication Modules Hand-Held LCD Display, Full Numeric Keypad -HIM-A Human Interface Modules LCD Display, Programmer Only -HIM-A Door-Mounted Remote (Panel Mount) LCD Display, Full Numeric Keypad -HIM-CS Human Interface Modules LCD Display, Programmer Only HIM (includes m cable) -HIM-CS PowerFlex HIM Interface Cable, m ( in) -HIM-H Cable Kit (Male-Female). m (. ft) -H Human Interface Module Cable Kit (Male-Female) m (. ft) -H Interface Cables Cable Kit (Male-Female) m (. ft) -H Cable Kit (Male-Female) m (. ft) -H DPI/SCANport One to Two Port Splitter Cable -S (IP/Type ) For Use With RS DF Communication Adapter -COMM-S PROFIBUS DP Communication Adapter -COMM-P ControlNet Communication Adapter (Coax) -COMM-C Interbus Communication Adapter -COMM-I Communication Modules Modbus/TCP Communication Adapter Bulletin SMC-Flex -COMM-M DeviceNet Communication Adapter -COMM-D EtherNet/IP Communication Adapter -COMM-E HVAC Communication Adapter -COMM-H ControlNet Communication Adapter (Fiber) -COMM-Q DriveTools Programming Software WIN NT//XP -DTEENE DriveTools Sp Programming Software WIN NT//XP -DTSENE AnaCANda RS- to DPI PC Interface Serial -SSS Requires a -HIM-H cable to connect to the SMC Flex. DPI to USB PC Interface USB -USB Publication A-CAA-EN-P -

13 Bulletin Specifications Standard Features Optional Features Installation Setup Communications Power Wiring Control Wiring Keypad Software Starting and Stopping Modes Protection and Diagnostics Metering Alarm Contact Status Indication Auxiliary Contacts Pump Control Braking Control SMB Smart Motor Braking Accu-Stop Slow Speed with Braking Functional Design Specifications Standard squirrel-cage induction motor or a Wye-Delta, six-lead motor. - and -wire control for a wide variety of applications. Front keypad and backlit LCD display. Parameter values can be downloaded to the SMC-Flex Controller with DriveTools programming software and the -COMM DPI communication module. One DPI provided for connection to optional human interface and communication modules. Soft Start Current Limit Start Dual Ramp Full Voltage Linear Speed Acceleration Preset Slow Speed Soft Stop Power loss, line fault, voltage unbalance, excessive starts/hour, phase reversal, undervoltage, overvoltage, controller temp, stall, jam, open gate, overload, underload, communication fault. Amps, volts, kw, kwh, MW, MWH, elapsed time, power factor, motor thermal capacity usage. Overload, underload, undervoltage, overvoltage, unbalance, jam, stall, and ground fault Stopped, starting, stopping, at speed, alarm, and fault. Four fully programmable contacts as normal/up-to-speed/fault/alarm/network (N.O./N.C.), or external bypass (N.O. only). Helps reduce fluid surges in centrifugal pumping systems during starting and stopping period. Starting time is adjustable from s. Stopping time is adjustable from s. Provides motor braking without additional equipment for applications that require the motor to stop quickly. Braking current is adjustable from % of the motor s full-load current rating. Provides controlled position stopping. During stopping, braking torque is applied to the motor until it reaches preset slow speed (% or % of rated speed) and holds the motor at this speed until a stop command is given. Braking torque is then applied until the motor reaches zero speed. Braking current is programmable from % of full-load current. Used on applications that require slow speed (in the forward direction) for positioning or alignment and also require braking control to stop. Wiring Diagram Line Controller -Phase Input Power Branch Protection SMC-Flex Controller Motor Fan Option Input # Option Input # Stop Start SMC-Flex Control Terminals Aux # PTC Input TACH Input Ground Fault Customer supplied. Aux # Aux # Aux # - Publication A-CAA-EN-P

14 Bulletin Specifications Power Circuit Control Circuit Electrical Ratings Device Rating UL/CSA/NEMA IEC V V AC ( %, +%) V Rated Operation Voltage V V AC ( %, +%) V V V AC ( %, +%) V/Y ( %, +%) V V Rated Insulation Voltage V N/A V V V V Rated Impulse Voltage V N/A V V V Dielectric Withstand V V AC V V V V V Repetitive Peak Inverse V V V Voltage Rating V V V Operating Frequency All / Hz Utilization Category A MG AC-B:.-: A MG AC-B:.-: A IP Protection Against Electrical A N/A IPX (with terminal covers) Shock A IP (open device) DV/DT Protection V & V RC Snubber Network V None Transient Protection V & V Metal Oxide Varistors: Joules V None Rated Operational Voltage A V AC or V AC/DC A /V AC and /V AC Rated Insulation Voltage All N/A V Rated Impulse Voltage All N/A V Dielectric Withstand All V AC V Operating Frequency All / Hz Input onstate voltage minimum V AC,.V DC /.V AC Input onstate current AC / V AC,. V AC/DC Input offstate voltage maximum V AC, V DC / V AC Input offstate input offstate voltage < ma AC, < ma DC V power is only available with V control. Publication A-CAA-EN-P -

15 Bulletin Specifications Short-Circuit Protection Electrical Ratings SCPD Performance V Type SCCR List Max. Standard Max. Standard Max. Standard Max. Circuit Available Fault Fuse [A] Available Fault Breaker [A] Line Device Operational Current Rating [A] Delta Device Operational Current Rating [A] Max. High Fault ka ka ka ka ka ka ka ka ka ka ka ka ka ka ka ka ka ka ka ka ka ka ka ka ka ka ka ka ka ka ka ka ka ka ka ka ka ka ka ka ka ka ka ka ka ka ka ka Max. Fuse [A]. ka ka ka. ka ka ka ka ka ka ka ka ka ka ka ka ka ka ka ka ka ka ka ka ka ka ka ka ka ka ka ka ka ka ka ka ka ka ka ka ka ka ka ka ka ka ka ka ka SCPD Performance V Type SCCR List Device Max. Ampere Tested North Max. Ampere Tested Max. Standard Available Fault Rating American Style European Style ka AURDxxx, grb xxx,urdxxx ka AURDxxx, grb xxx,urdxxx ka AURDxxx, grb xxx,urdxxx ka AURDxxx, grb xxx,urdxxx Maximum FLC ka AURDxxx, grb xxx,urdxxx ka AURDxxx, grb xxx,urdxxx ka ADxxx URD xxx AURDxxx,URDxxx ka AURDxxx,URDxxx ka AURDxxx,URDxxx ka Two fuses in parallel Two fuses in parallel AURDxxx,URDxxx ka Two fuses in parallel Two fuses in parallel AURDxxx,URDxxx Consult local codes for proper sizing of short circuit protection. Non-time delay fuses (K V (. A) devices; Class L V ( A) devices). High capacity fault rating when used with time delay class CC, J, or L fuses. Type performance/protection indicates that, under a short-circuit condition, the fused or circuit breaker-protected starter shall cause no danger to persons or installation but may not be suitable for further service without repair or replacement. For short-circuit current rating (SCCR) for enclosed panel with external bypass or isolation contactor, see the Industrial Controls catalog website:. - Publication A-CAA-EN-P

16 Bulletin Specifications Power Requirements Steady State Heat Dissipation with Control and Fan Power (Watts) Auxiliary Contacts / (Aux #) / (Aux #) / (Aux #) / (Aux #) PTC Input Ratings Tach Input Electrical Ratings V AC Transformer VA V AC Transformer VA Inrush Current A Inrush Time ms Control Module A Transient Watts W V DC Transient Time ms Steady State Watts W Minimum Allen-Bradley Power Supply -XLPE A VA (recommended VA) A, VA Heatsink Fan(s) A, VA A, VA A, VA Controller Rating [A] Type of Control Circuit Electromagnetic relay Number of Contacts Type of Contacts programmable N.O./N.C. Type of Current AC Rated Operational Current V AC,. V AC Conventional Thermal CurrentI th AC/DC A Make/Break VA / Utilization Category AC-/DC Response Resistance Ω ± Ω Reset Resistance Ω ± Ω Short-Circuit Trip Resistance Ω ± Ω Max. Voltage at PTC Terminals (R PTC = kω) <.V Max. Voltage at PTC Terminals (R PTC = open) V Max. No. of Sensors. Max. Cold Resistance of PTC Sensor Chain Ω Response Time ms V DC,.V DC = % Speed Heatsink fans can be powered by either /V AC or /V AC. Publication A-CAA-EN-P -

17 Bulletin Specifications Environmental Operating Temperature Range - + C ( + F) (open) - + C ( + F) (enclosed) Storage and Transportation Temperature Range - + C (- F) Altitude m ( ft) Humidity % (non-condensing) Pollution Degree Resistance to Vibration Resistance to Shock Construction Terminals EMC Emission Levels EMC Immunity Levels Overload Characteristics Certifications Mechanical Operational All. G Peak,. mm (. in.) displacement Non-Operational A. G Peak,. mm (. in.) displacement A. G Peak,. mm (. in.) displacement A G Operational A. G A G A G Non-Operational A G A G Power Poles A Heatsink thyristor modular design Power Poles A Heatsink hockey puck thyristor modular design Control Modules Thermoset and Thermoplastic Moldings Metal Parts Plated Brass, Copper, or Painted Steel Cable size Line Upper. mm ( / AWG) Line Lower.. mm ( AWG) A Load Upper. mm ( AWG) Load Lower.. mm ( AWG) Tightening torque. N m ( lb.-in.) Power Terminals Wire strip length mm (.. in.) A One M x. diameter hole per power pole A Two M x. diameter holes per power pole A Two M x. diameter holes per power pole A Two. mm (. in.) diameter holes per power pole Power Terminal Markings NEMA, CENELEC EN Control Terminals M screw clamp Clamping yoke connection Other Conducted Radio Frequency Emissions Class A Radiated Emissions Class A Electrostatic Discharge kv Air Discharge Radio Frequency Electromagnetic Field Per EN/IEC -- Fast Transient Per EN/IEC -- Surge Transient Per EN/IEC -- Line Delta Current Range [A] Trip Classes Trip Current Rating Number of Poles Open-Type Controllers,,, and % of Motor FLC CE Marked Per Low Voltage Directive //EEC, //EEC UL Listed (File No. E) - Publication A-CAA-EN-P

18 Bulletin Approximate Dimensions Dimensions are in millimeters (inches). Dimensions are not intended for manufacturing purposes. Approximate Dimensions and Shipping Weights Open Type Controllers Rating [A] Height Width Depth Weight (.). (.) (.) (.) Enclosed-Type Line-Connected Controllers Factory-installed options may affect enclosure size requirements. Exact dimensions can be obtained after order entry. Please consult your local Rockwell Automation sales office or Allen-Bradley distributor. A. (.). (.) (.). (.) (.) (.). (.). (.) D (.). (.). (.). (.). (.). (.) C. kg (. lbs). kg ( lbs).. kg ( lbs).. kg ( lbs) kg ( lbs) kg ( lbs) A D E C B E B F F Figure Wall-Mount Figure Wall-Mount C LIFTING ANGLE C B B A Figure Floor-Mount A Figure Floor-Mount Publication A-CAA-EN-P -

19 Bulletin Approximate Dimensions Controller Rating [A] Bulletin With Option H,H,B,B Assumed line voltage to be V AC. Different voltage may necessitate a bigger enclosure size. Consult your local Rockwell Automation sales office or Allen-Bradley distributor. Hp max. V AC, V V AC, V - H,H,B,B Dimension Figure No. Publication A-CAA-EN-P Dimensions in inches (mm) A (Width) B (Height) C (Depth) D (Mtg. Dim.) E (Mtg. Dim.) F (Mtg. Dim.) SMC-Flex Combination Controller () () (). (). (). () BP,NB,NI,_ () () (). (). () H, B () () (). (). () BP, _ () () (). (). (). () NI, NB () () (). (). () () () (). (). () H, H,B _ () () (). (). (). () H,B () () (). (). () H,B, B,H NI, NB () () (). (). () B, H () () (). (). () B,H () () (). (). () H, H,B _ () () (). (). (). () BP () () (). (). () H BP, _ () () (). (). () B, H,B BP,NB,NI () () (). (). () H,H () () (). (). () _ () () (). (). (). () H,B,H,B BP, NB,NI () () (). (). () H,H () () (). (). () _ () () (). (). (). () H,B,H,B BP, NB,NI () () (). (). () H,H () () (). (). () _ () () (). (). (). () B,B,H,H BP, NB,NI () () (). (). () H,H () () (). (). () _ () () (). (). (). () B,B,H,H BP, NB,NI () () (). (). () H () () (). (). () _ () () (). (). (). () BP,NB () () (). (). () B () () (). (). () H,B () () (). (). (). () _ () () (). (). () B,B,H NB,NI () () () H () () (). (). () _ () () (). (). (). () BP () () (). (). () B () () (). (). () H, B () () (). (). (). () H _ () () (). (). () H,B,B,H NB,NI () () () H () () (). (). () _ () () (). (). (). () H,B BP,NI () () (). (). () H () () (). (). (). () BP () () (). (). () NB () () () (). () () H.B BP,NB,NI () () () B BP,NB,NI,_ () () () H,B BP,NB,NI (). () () B (). () () B,H,B,H NB (). () () H (). () () BP (). () () B,H (). () () B (). () () B,H BP,NI (). () () B,H,B,H NB (). () () B,H (). () ()

20 Bulletin Approximate Dimensions Controller Rating [A] Bulletin With Option Dimension Figure No. Dimensions in inches (mm) A (Width) B (Height) C (Depth) D (Mtg. Dim.) E (Mtg. Dim.) F (Mtg. Dim.) Non-Combination Controller () () (). (). () _ () () (). (). () BP () () (). (). (). (), B NB,NI () () (). (). () NB,P_ () () (). (). () () () (). (). () () () (). (). () B BP () () (). (). (). () _ () () (). (). () NB () () (). (). (), B NI () () (). (). () B () () (). (). () () () (). (). () BP () () (). (). (). () NB () () (). (). () _ () () (). (). (), B NB,NI,P_ () () (). (). () B () () (). (). () BP () () (). (). () NB () () (). (). (). () () () (). (). () NB,NI () () (). (). () () () (). (). () BP () () (). (). () B () () (). (). (). () NB () () (). (). () B NB,NI () () (). (). () () () (). (). (). (),B NB,NI,BP,_ () () (). (). () () () (). (). (). (),B NB,NI,BP,_ () () (). (). () NB,NI,BP,_ () () (). (). (). () B NB,NI,BP,_ () () (). (). () NB,NI,BP,_ () () (). (). (). () B NB,NI,BP,_ () () (). (). () () () (). (). (). (), B BP,NB,NI () () (). (). () B B (). () () BP,NB (). () () (). () () NB (). () () (). () () BP,NB (). () () (). () () NB (). () () Extra capacity transformer may require a larger enclosure; consult your local Rockwell Automation sales office or Allen-Bradley distributor. kva control transformers or larger extra capacity transformers may require a larger enclosure; consult your local Rockwell Automation sales office or Allen-Bradley distributor. Publication A-CAA-EN-P -

Enclosures other than those listed are available; consult your local Rockwell Automation sales office or Allen-Bradley distributor.

Enclosures other than those listed are available; consult your local Rockwell Automation sales office or Allen-Bradley distributor. Bulletin Product Selection Open Type and Non-Combination Enclosed (IP, Type /) Controllers For use with Line-Connected Motors Enclosures other than those listed are available; consult your local Rockwell

More information

Allen-Bradley 150-F108NBD

Allen-Bradley 150-F108NBD Bulletin Product Selection Open Type and Non-Combination Enclosed (IP, Type /) Controllers For use with Line-Connected Motors Enclosures other than those listed are available; consult your local Rockwell

More information

V AC, 50/60 Hz 150-F251NCD 150-F251FCD 24V AC/DC 150-F5NCR

V AC, 50/60 Hz 150-F251NCD 150-F251FCD 24V AC/DC 150-F5NCR Bulletin Product Selection Open Type and Non-Combination Enclosed (IP, Type /) Controllers For use with Line-Connected Motors, Continued Enclosures other than those listed are available; consult your local

More information

Bulletin 150 SMC Flex Smart Motor Controllers Product Overview/Modes of Operation/Features

Bulletin 150 SMC Flex Smart Motor Controllers Product Overview/Modes of Operation/Features Bulletin Product Overview/Modes of Operation/Features Bulletin SMC Flex Smart Motor Controller The SMC Flex controller provides microprocessor controlled starting for standard -phase squirrel-cage induction

More information

150 B180 N B D A 8L. Enclosure Type. Input Line Voltage Open Type V AC, 3-phase, 50 and 60 Hz V AC, 3-phase, 50 and 60 Hz

150 B180 N B D A 8L. Enclosure Type. Input Line Voltage Open Type V AC, 3-phase, 50 and 60 Hz V AC, 3-phase, 50 and 60 Hz Catalog Number Explanation Open Controllers a Bulletin Number Solid-State Controller B H H B B B B B B B B B B B B B Solid-State Controller and Isolation Contactor (enclosed only) b Controller Ratings

More information

152H F480 F BD B 59 8B

152H F480 F BD B 59 8B ulletin Catalog Number Explanation Open and Non-Combination F F D L a ulletin Number Solid-State Controller F F F F F F F F F F F F F F F F Combination H H F F F F F F F F F F F F F F Enclosed Solid-State

More information

Hp V AC Current Rating [A] 230V AC 60 Hz

Hp V AC Current Rating [A] 230V AC 60 Hz Product Selection/Options Open Type Controllers Up to V AC kw Hp V AC Current Rating [A] V AC Hz V AC Hz V AC Hz V AC Hz V AC Hz / Hz Control V AC/DC Control.. -BNBD -BNBR. -BNBD -BNBR -BNBD -BNBR -BNBD

More information

Control Power V AC, 50/60 Hz 150-C30NBD 150-C30FHD

Control Power V AC, 50/60 Hz 150-C30NBD 150-C30FHD Bulletin Product Selection Open Type and Non-Combination Enclosed (IP, NEMA /) Controllers For use with Line-Connected Motors Rated Voltage [V AC] / Motor Current [A]...... Max. kw, Hz Max. Hp, Hz Control

More information

150 C 30 F B D 8L 152H C 30 F BD 43 8L

150 C 30 F B D 8L 152H C 30 F BD 43 8L SM - Smart Motor ontrollers atalog Number Explanation Open and Non-ombination F D L a b c d e f g a ulletin Number ode Solid-State ontroller b ontroller Type ode SM- c Ampere s ode A A A A A A A A A A

More information

SMC Flex Specifications

SMC Flex Specifications Technical Data MC Flex pecifications ulletin Number 50 Topic Page Product Overview 2 tandards Compliance and Certifications 2 Features 3 Catalog Number Explanation 4 General pecifications 6 Approximate

More information

SMC Dialog Plus Specifications

SMC Dialog Plus Specifications Technical Data MC Dialog Plus pecifications Bulletin Number 150 Topic Page Product Overview 2 tandards Compliance and Certifications 2 Modes of Operation 3 Features 5 Catalog Number Explanation 6 General

More information

Dual Ramp Start Current Limit Start with Selectable Kickstart Full Voltage Start Options include: Soft Stop. SMB Smart Motor Braking Pump Control

Dual Ramp Start Current Limit Start with Selectable Kickstart Full Voltage Start Options include: Soft Stop. SMB Smart Motor Braking Pump Control Overview/ of Features Standards Compliance UL 0 CSA C. No. EN/IEC 0- EN/IEC 0-- SMC Dialog Plus Smart Motor Controller The SMC Dialog Plus controller provides microprocessor controlled starting for standard

More information

Size for Size Best Value in the Industry

Size for Size Best Value in the Industry Size for Size Best Value in the Industry Overview for SMC -Flex and SMC -3 Soft ers 3...480A 200-460VAC...500-575VAC www.klinkmann.com Allen-Bradley Smart Motor Controllers... Providing Unmatched Intelligent

More information

Softstarter Intelligent Controllers

Softstarter Intelligent Controllers Softstarter Intelligent Controllers Series Modes of Operation (Standard) Soft Start 100% Percent Voltage Initial Torque Start Run This method has the most general application. The motor is raised from

More information

Application Description

Application Description -14 Type, Intelligent Technologies (IT.) Soft Starters February 2007 Contents Description Page Type, Intelligent Technologies (IT.) Soft Starters Product Description....... -14 Application Description....

More information

RVS-DN Digital Reduced Voltage Motor Starter

RVS-DN Digital Reduced Voltage Motor Starter RVS-DN Digital Reduced Voltage Motor Starter Specification Guide Specification Guide Contents 1.0 Introduction 2.0 Specifications 2.1 Standard Performance Features 2.2 Standard Protection Features 2.3

More information

825-P Modular Protection System for motors Specification Guide

825-P Modular Protection System for motors Specification Guide Specification Guide 1.0 General 1.01 The motor protection relay shall have a current operating range of 0.5 and 5000 amperes. 1.02 The motor protection relay shall provide current measurement-based protection

More information

The Enclosed Altistart 22 Soft Start/Soft Stop Motor Controller

The Enclosed Altistart 22 Soft Start/Soft Stop Motor Controller The Enclosed Altistart 22 Soft Start/Soft Stop Motor Controller A pre-engineered solution with an integrated circuit breaker disconnect and an Altistart 22 soft start in a stand-alone enclosure Make the

More information

DRAFT 1400HP 1000HP 100HP. Reduced Voltage Solid State Starters. Softstarters SOFT. PF Controller PCS Controller PDS Controller V 1...

DRAFT 1400HP 1000HP 100HP. Reduced Voltage Solid State Starters. Softstarters SOFT. PF Controller PCS Controller PDS Controller V 1... 100HP 400HP 700HP 1000HP 1400HP PCS Softstarter Controller IN-rail mountable microprocessor controller for 3-phase motors up to 480A (3...85A din-rail mountable) Provides three different starting modes

More information

RVS-DX Digital Reduced Voltage Motor Starter

RVS-DX Digital Reduced Voltage Motor Starter RVS-DX Digital Reduced Voltage Motor Starter Specification Guide Specification Guide Contents 1.0 Introduction 2.0 Specifications 2.1 Standard Performance Features 2.2 Standard Protection Features 2.3

More information

SMC -50 Reduced Voltage Solid-State Smart Motor Controllers

SMC -50 Reduced Voltage Solid-State Smart Motor Controllers ROCKWELL AUTOMATION PROCUREMENT SPECIFICATION PROCUREMENT SPECIFICATION SMC -50 Reduced Voltage Solid-State Smart Motor Controllers NOTICE: The specification guidelines in this document are intended to

More information

SECTION MOTOR CONTROL

SECTION MOTOR CONTROL SECTION 26 24 19 MOTOR CONTROL PART 1 - GENERAL 1.1 SECTION INCLUDES A. Manual motor starters B. Magnetic motor starters C. Combination magnetic motor starters D. Solid-state reduced voltage motor starters

More information

Softstarters. Softstarters Type SSM Medium voltage ,800V 1

Softstarters. Softstarters Type SSM Medium voltage ,800V 1 Medium voltage 2300 13,800V 1 Description Fused disconnect switch with blown fuse indicators and door safety interlocks rated for load break/fault make with automatic grounding arm Inline isolation vacuum

More information

Presentation Soft starters 0 Altistart 48 soft start - soft stop units

Presentation Soft starters 0 Altistart 48 soft start - soft stop units Presentation Soft starters 5 6 7 65_Ver.-EN.fm/ Presentation (continued) Soft starters Applications The Altistart 8 soft start - soft stop unit is a controller with 6 thyristors which is used for the torque-controlled

More information

RVS-AX Instruction Manual

RVS-AX Instruction Manual RVS-AX Analog Soft Starter 8-170A, 220-600V Instruction Manual Ver. 10/11/2009 2 Table of Content RVS-AX Instruction Manual 1. TABLE OF CONTENT 1. Table of Content...2 2. Safety & Warnings...3 2.1 Safety...3

More information

1.2. Reduced Voltage Motor Starters. Contents Description Type S611, Solid-State Soft Starters... Type S801+, Soft Starters. Solid-State Starters

1.2. Reduced Voltage Motor Starters. Contents Description Type S611, Solid-State Soft Starters... Type S801+, Soft Starters. Solid-State Starters .2 Type S80+, Soft Starters Contents Description Type S6, Solid-State Soft Starters........... Type S80+, Soft Starters Operation............................. Features.............................. Benefits...............................

More information

Selection Guide. PowerFlex Digital DC Drive

Selection Guide. PowerFlex Digital DC Drive Selection Guide PowerFlex Digital DC Drive PowerFlex Digital DC Drive The PowerFlex DC drive combines powerful performance with flexible control to produce a highly functional, cost effective drive and

More information

STC Starting Torque Controller A Ratings Reduces Starting Torque Surge Feed-Through Wiring Single- and Three-Phase Page 7-3

STC Starting Torque Controller A Ratings Reduces Starting Torque Surge Feed-Through Wiring Single- and Three-Phase Page 7-3 7 Bulletin 150 Reduced Voltage Starters Section Overview STC Starting Torque Controller 11 22 Ratings Reduces Starting Torque Surge Feed-Through Wiring Single- and Three-Phase Page 7-3 SMC-2 Smart Motor

More information

Standard Features 200-600V, 50/60Hz input power supply Built-in run rated (AC1) By-pass contactor up to 820 A * Rated 450% current Conformal coated circuit board Voltage ramp or current limit start modes

More information

2.1 Warnings & Agency Approvals Electrical Connections - Specifications Standard Wiring Configurations...2 4

2.1 Warnings & Agency Approvals Electrical Connections - Specifications Standard Wiring Configurations...2 4 CHAPTER ELECTRICAL 2 INSTALLATION Contents of this Chapter... 2.1 Warnings & Agency Approvals..................2 2 2.1.1 Isolation..............................................2 2 2.1.2 Electrical Power

More information

Selection Guide. Control Circuit and Load Protection

Selection Guide. Control Circuit and Load Protection Selection Guide Control Circuit and Load Protection Circuit Protection Portfolio 1489-M Circuit Breakers Approved for branch circuit protection in the United States and Canada, and certified as Miniature

More information

Motor Starters. Reduced Voltage. Reduced Voltage Motor Starters Contents

Motor Starters. Reduced Voltage. Reduced Voltage Motor Starters Contents June 5 Vol. 2, Ref. No. [067] -1 Reduced Voltage Motor Starters Contents Description Page Solid-State Controllers Type S701, Soft Start.......................................... -2 Type TL, Torque Limiter........................................

More information

1.2. Reduced Voltage Motor Starters. Contents Description Type S611, Soft Starters... Type S801+, Soft Starters. Type S801+, Soft Starters

1.2. Reduced Voltage Motor Starters. Contents Description Type S611, Soft Starters... Type S801+, Soft Starters. Type S801+, Soft Starters Reduced Voltage Motor Starters.2 Type S80+, Soft Starters Contents Type S6, Soft Starters..................... Type S80+, Soft Starters Operation.............................. Features...............................

More information

Bulletin 825 SMM Smart Motor Manager

Bulletin 825 SMM Smart Motor Manager Bulletin 825 SMM Smart Motor Manager Your order must include: Cat. no. of the Smart Motor Manager selected with supply Voltage Suffix Code, Cat. no. of Converter Module selected, and, If required, Cat.

More information

Product Description. Application Description

Product Description. Application Description -2 Solid-State Controllers Type TL, Torque Limiter August 6 Contents Description Page Torque Limiters............ -2 Soft Start Controllers........ -4 Soft Start Controllers with Auxiliary Contact.....

More information

Burden Fuse Rating Resistor SAF / SAK6 1NM 10mm M8 12NM SAF / SAK10 2NM 16mm M8 12NM

Burden Fuse Rating Resistor SAF / SAK6 1NM 10mm M8 12NM SAF / SAK10 2NM 16mm M8 12NM Contents Section Page 1.0 Introduction 1 2.0 Specification 1-4 3.0 Installation 5-8 4.0 Programming 9-10 5.0 Menus 10-12 6.0 Fault Finding/Diagnostics 12-13 7.0 Communication 13 8.0 Setting Up 13-16 1.0

More information

SECTION VARIABLE FREQUENCY DRIVE UNITS

SECTION VARIABLE FREQUENCY DRIVE UNITS SECTION 26 29 23 PART 1 - GENERAL 1.1 THE REQUIREMENT A. General: The CONTRACTOR shall provide variable frequency drive (VFD) units, complete and operable, in accordance with the Contract Documents. It

More information

Softstarters Softstarters

Softstarters Softstarters , PSS & PST(B), PSS & PST(B) Low Voltage Products & Systems 6.1 General information PSR PSS From the moment the first electrical motors appeared, engineers have been searching for a way to avoid electrical

More information

Model Number Structure. Characteristics. Model Number Legend. Soft Starter. Applicable Motors. Accessories

Model Number Structure. Characteristics. Model Number Legend. Soft Starter. Applicable Motors. Accessories Three-phase Hybrid Soft er (Soft, Kick, Current Limit, Soft Stop) CSM DS_E_6_1 Built-in Bypass Relay and Smooth s/stops Achieved in a Compact er Advanced functions include soft start, kick start, and soft

More information

SOLSTART Instruction Manual

SOLSTART Instruction Manual Solstart Analog Soft Starter 8-58A, 220-600V Instruction Manual Ver. 23/03/2009 2 Table of Content SOLSTART Instruction Manual 1. TABLE OF CONTENT 1. Table of Content...2 2. Safety & Warnings...3 2.1 Safety...3

More information

Features and Benefits

Features and Benefits -52 August 2006 Contents Page Type MV801, Intelligent Technologies (IT.) Medium Voltage Soft Starters Operation.............. -53 Selection.............. -55 Product Selection........ -56 Options................

More information

CENTERLINE 2500 Low Voltage Motor Control Centers and Switchgear Assemblies

CENTERLINE 2500 Low Voltage Motor Control Centers and Switchgear Assemblies Selection Checklist CENTERLINE 2500 Low Voltage Motor Control Centers and Switchgear Assemblies Use this checklist to help you configure your CENTERLINE 2500 Motor Control Center. You can type in the fields

More information

A. Provide variable frequency drives to operate variable torque loads as shown on the Drawings and as specified herein.

A. Provide variable frequency drives to operate variable torque loads as shown on the Drawings and as specified herein. DIVISION 23 HEATING, VENTILATING, AND AIR CONDITIONING (HVAC) SECTION 23 90 71 PART 1 GENERAL 1.01 DESCRIPTION A. Provide variable frequency drives to operate variable torque loads as shown on the Drawings

More information

Soft Starter. Types RSBD. Product Description. Type Selection. Ordering Code RSB D E V 61 HP

Soft Starter. Types RSBD. Product Description. Type Selection. Ordering Code RSB D E V 61 HP Soft Starter Three-Phase Scroll Compressor Soft Starter Types RSBD Soft starting of 3-phase scroll compressors up to 95Amp Patented auto-adaptive algorithm for optimum inrush current reduction (No user

More information

Motor Starters. Reduced Voltage. Reduced Voltage Motor Starters 1. Contents

Motor Starters. Reduced Voltage. Reduced Voltage Motor Starters 1. Contents 1 January 00 Reduced Voltage Motor Starters Contents Description Page Open Type S7, Intelligent Technologies (IT.) Soft Starters Product Description............................................. Application

More information

INSTALLATION INSTRUCTIONS FOR SYMCOM'S MODEL 777-HVR-SP ELECTRONIC OVERLOAD RELAY

INSTALLATION INSTRUCTIONS FOR SYMCOM'S MODEL 777-HVR-SP ELECTRONIC OVERLOAD RELAY CONNECTIONS INSTALLATION INSTRUCTIONS FOR SYMCOM'S MODEL 777-HVR-SP ELECTRONIC OVERLOAD RELAY BE SURE POWER IS DISCONNECTED PRIOR TO INSTALLATION!! FOLLOW NATIONAL, STATE AND LOCAL CODES! READ THESE INSTRUCTIONS

More information

1489-M Circuit Breakers

1489-M Circuit Breakers Dual terminals provide wiring/bus bar flexibility and clamp from both sides to improve connection reliability Terminal design helps prevent wiring misses Scratch- and solventresistant printing Suitable

More information

MCD 200 Series Soft Starters

MCD 200 Series Soft Starters MCD 200 Series Soft Starters AC motors often cause one or more serious problems during startup acceleration. MCD 200 Series electronic soft starters control motor current to provide a smooth start. When

More information

ATS22D88Q soft starter-ats22-control 220V-power 230V (22kW)/ V(45kW)

ATS22D88Q soft starter-ats22-control 220V-power 230V (22kW)/ V(45kW) Product datasheet Characteristics ATS22D88Q soft starter-ats22-control 220V-power 230V (22kW)/400...440V(45kW) Complementary Assembly style Function available Supply voltage limits Main Range of product

More information

Features and Benefits. Control Features

Features and Benefits. Control Features Features and Benefits AC induction motors have become increasingly dominant in industrial facilities worldwide. Manufacturers faced with increasing pressure to control costs have recognized that motor

More information

Softstarters Type PSS. Softstarters. General information

Softstarters Type PSS. Softstarters. General information General information The PSS Softstarter line brings a wide array of benefits for smaller motors in a flexible, compact form. The PSS "Flexible" Softstarter line PSS18/30 to PSS300/515 softstarters provide

More information

1.1 Caution Statements

1.1 Caution Statements USER MANUAL 1.1 Caution Statements Caution Statements cannot cover every potential cause of equipment damage but can highlight common causes of damage. It is the installer's responsibility to read and

More information

WARREN COUNTY, N.Y. M/E REFERENCE A. Submit manufacturer's product data on all motors and adjustable speed drives.

WARREN COUNTY, N.Y. M/E REFERENCE A. Submit manufacturer's product data on all motors and adjustable speed drives. SECTION 230513 - MOTORS AND ADJUSTABLE SPEED DRIVES PART 1 - GENERAL 1.1 DESCRIPTION A. Provide labor, materials, equipment and services as required for the complete installation designed in Contract Documents.

More information

Technical Information

Technical Information -100 Controller IEC Performance Data (CSA C22.2, UL 508 No. 14 in connection with a short-circuit protection device Catalog No. -100... 25A 40A 63A 90A Maximum Short-Circuit Current 480V [ka] 65 65 42

More information

CTi Automation - Phone: Fax: Web:

CTi Automation - Phone: Fax: Web: CTi Automation - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.ctiautomation.net - Email: info@ctiautomation.net The control & protection you expect in an innovative soft starter design... Flexibility

More information

300% Motor full load amps at 80 seconds, 400% Motor full load amps at 35 seconds

300% Motor full load amps at 80 seconds, 400% Motor full load amps at 35 seconds Digital Soft Start Controls 9 thru 900 Amps 208-460V 50/60 Hz. 9 thru 900 Amps 208-575V 50/60 Hz. Applications: Controlled ramp start and stop, minimize spillage in material handling, reduced water hammer

More information

PowerFlex Digital DC Drive

PowerFlex Digital DC Drive Technical Data PowerFlex Digital DC Drive Table of Contents Topic Page Additional Resources 3 Product Description 3 Standard Drives Program 4 Catalog Number Explanation 6 Standard Drives Product Selection

More information

DATASHEET - DILMC9-10(24VDC) Technical data General. Contactor, 3p+1N/O, 4kW/400V/AC3. Catalog No Eaton Catalog No. XTCEC009B10TD.

DATASHEET - DILMC9-10(24VDC) Technical data General. Contactor, 3p+1N/O, 4kW/400V/AC3. Catalog No Eaton Catalog No. XTCEC009B10TD. DATASHEET - DILMC9-10(24VDC) Technical data General Contactor, 3p+1N/O, 4kW/400V/AC3 Part no. DILMC9-10(24VDC) Catalog No. 277468 Eaton Catalog No. XTCEC009B10TD EL-Nummer 4110305 (Norway) Standards IEC/EN

More information

SmartVFD HVAC FEATURES APPLICATION SPECIFICATION DATA

SmartVFD HVAC FEATURES APPLICATION SPECIFICATION DATA SmartVFD HVAC APPLICATION The SmartVFD HVAC is a variable frequency drive designed for use in HVAC application to control the speed of HVAC pumps and fans in order to maximize energy efficiency. Smart

More information

Application example of a motor controlled by MCD100 and protected by a circuit breaker

Application example of a motor controlled by MCD100 and protected by a circuit breaker VLT T Soft Start Controller MCD 100 MCD 100 is a cost effective and extremely compact soft starter for AC motors up to 11 kw. Due to a unique semiconductor design MCD 100 is a true fit and forget product.

More information

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC AF09... AF0 -pole Contactors up to 25 HP / 600 VAC Contactors and Overload Relays Overview.../0 AF09... AF0 -pole Contactors.../2 Main Technical Data.../8 Main Accessory Fitting Details.../2 Main Accessory.../24

More information

Low and Medium Voltage Industrial Soft Starters

Low and Medium Voltage Industrial Soft Starters Low and Medium Voltage Industrial Soft Starters An extensive range to minimise costs by reducing system requirements, wear and tear on equipment. MOTOR CONTROL AND DRIVES Myriad Pro Condensed 12 pt Capitals

More information

Bulletin 109 IEC Non-Reversing Starters. Product Overview/Product Selection. Table of Contents

Bulletin 109 IEC Non-Reversing Starters. Product Overview/Product Selection. Table of Contents Bulletin IEC Non-Reversing Starters Product Overview/Product Selection Cat. No. -CABAF--R-P IP (Type ) Metal Enclosure with Lift-off Cover Bulletin IEC Non-Reversing Starters Impact-resistant molded enclosures

More information

AF40... AF96 3-pole contactors Technical data

AF40... AF96 3-pole contactors Technical data Main pole - Utilization characteristics according to IEC Standards IEC 60947- / 60947-4- and EN 60947- / 60947-4- Rated operational voltage Ue max. 690 V Rated frequency (without derating) 50 / 60 Hz Conventional

More information

BR Second Position Voltages. AA Fourth Position

BR Second Position Voltages. AA Fourth Position 1336S First Position Bulletin Number BR Second Position Voltage Letter AQ BR CW A B BP BX C Q R RX W Voltages 200-240V AC or 3V DC 380-480VAC or 513-620V DC 500-600V AC or 775V DC or 200-240V AC 380-480V

More information

CI-tronic Soft Start Motor Controller Type MCI 25B with Brake

CI-tronic Soft Start Motor Controller Type MCI 25B with Brake Data sheet CI-tronic Soft Start Motor Controller Type MCI 25B with Brake MCI 25B motor controller with brake is designed for soft starting and braking of 3 phase AC motors. The digital controlled soft

More information

KD LV Motor Protection Relay

KD LV Motor Protection Relay 1. Protection Features KD LV Motor Protection Relay Overload (for both cyclic and sustained overload conditions) Locked rotor by vectorial stall Running stall / jam Single phasing / Unbalance Earth leakage

More information

Motor Controllers AC Semiconductor Motor Controller Type RSHP Flexy

Motor Controllers AC Semiconductor Motor Controller Type RSHP Flexy otor Controllers AC Semiconductor otor Controller Type RSHP Flexy Soft starting and stopping of 3-phase squirrel cage motors Low surge and vibration-free starting User-selected ramping profiles Integral

More information

Phoenix DX Sensorless AC Vector Drive. 3 HP to 3500 HP

Phoenix DX Sensorless AC Vector Drive. 3 HP to 3500 HP Phoenix DX Sensorless AC Vector Drive 3 HP to 3500 HP Standard Features: * PRECISE CONTROL OF MOTOR SPEED AND TORQUE * BI-DIRECTIONAL FLYCATCHER (CATCH SPINNING MOTOR) * EASY TO USE, SIMPLE SETUP * POWER

More information

Bulletin 1489 Circuit Breakers. Selection Guide

Bulletin 1489 Circuit Breakers. Selection Guide Bulletin 1489 s Selection Guide Bulletin 1489-A Overview/Description Bulletin 1489-A s Energy-limiting design protects downstream components better than conventional breakers during short circuits Field-mountable

More information

team master medium voltage solid state starters

team master medium voltage solid state starters team master medium voltage solid state starters The Today s global economy is in many ways driven by the AC Induction Motor. Industrial facilities worldwide depend on these motors to drive the machinery

More information

Dimensions WxHxD [mm] Weight [kg]

Dimensions WxHxD [mm] Weight [kg] SPECIFICATIONS The SOLSTART electronic soft starter incorporates two sets of thyristors (Two phase control) to start a threephase squirrel cage induction motor and an internal bypass. By supplying a slowly

More information

CI-Tronic Soft start motor controller MCI 3, MCI 15, MCI 25, MCI 30 I-O, MCI 40-3D and MCI 50-3 I-O

CI-Tronic Soft start motor controller MCI 3, MCI 15, MCI 25, MCI 30 I-O, MCI 40-3D and MCI 50-3 I-O Data sheet CI-Tronic Soft start motor controller MCI 3, MCI 15, MCI 25, MCI 30 I-O, MCI 40-3D and MCI 50-3 I-O The MCI soft starters are designed for soft starting and stopping of 3 phase AC motors, thus

More information

Certifications UL Listed (File No. E 14841, Guide NLRV; File No. E 47426, Guide WHTY) CSA Certified (File No. LR1234) CE

Certifications UL Listed (File No. E 14841, Guide NLRV; File No. E 47426, Guide WHTY) CSA Certified (File No. LR1234) CE Bulletin R Overview Bulletin R Next Generation Global Fused and Non-Fused Disconnects 0 A A Sizes Fused Switch Versions: - BS - DIN - CSA HRCII-C - CSA HRCI-MISC - UL Class J - UL Class CC - NFC Non-Fused

More information

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION MOTORS, STARTERS & DRIVES

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION MOTORS, STARTERS & DRIVES PART 0 DESIGN STANDARDS 0.01 GENERAL DESIGN GUIDELINES A. Coordinate starter needs for mechanical equipment prior to 50% CD and confirm again for 100% CD submittal. B. Coordinate temperature controls requirements

More information

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC AF0... AF0 -pole Contactors up to 20 HP / 480 VAC Contactors and Overload Relays Overview...2 AF0... AF0 -pole Contactors Ordering Details...4 Main Technical Data...20 DC Circuit switching...2 Main Accessory

More information

Reduced Voltage Starters Section 2

Reduced Voltage Starters Section 2 Reduced Voltage Starters- ASTAT XT Soft Starter Description and Features...2-2 Product Number Configuration...2-3 NEMA and IEC Ratings...2-4 Technical Specifications...2-5 Functions...2-6 Overload Protections,

More information

Reduced Voltage Motor Starters

Reduced Voltage Motor Starters Reduced Voltage Motor Starters Soft Start Controllers. Solid-State Controllers Product Overview........................................ Type S70, Soft Start Controllers............................. Type

More information

Data sheet. CI-tronic Soft start motor controller Type MCI 3, MCI 15, MCI 25, MCI 30 I-O, MCI 50 I-O 520B1443

Data sheet. CI-tronic Soft start motor controller Type MCI 3, MCI 15, MCI 25, MCI 30 I-O, MCI 50 I-O 520B1443 CI-tronic Soft start motor controller Type MCI 3, MCI 15, MCI 25, MCI 30 I-O, MCI 50 I-O December 2002 DKACT.PD.C50.G2.02 520B1443 2 DKACT.PD.C50.G2.02 Danfoss A/S 12-2002 Introduction The MCI soft starters

More information

Motor Controllers AC Semiconductor Motor Controller Type RSHP Flexy

Motor Controllers AC Semiconductor Motor Controller Type RSHP Flexy Controllers AC Semiconductor Controller Type Soft starting and stopping of -phase induction squirrel cage motors Low inrush and reduced vibration during starting User-selected ramping profiles Integral

More information

Approved Standards. Ordering Information. Mini Motor Contactor J7KNA. Model Number Legend. Main contactor. Accessories. Mini Motor Contactor J7KNA 1

Approved Standards. Ordering Information. Mini Motor Contactor J7KNA. Model Number Legend. Main contactor. Accessories. Mini Motor Contactor J7KNA 1 Mini Motor Contactor J7KNA ) Main contactor AC & DC operated Integrated auxiliary contacts Screw fixing and snap fitting (35 mm DIN-rail) Range from 4 to 5.5 (AC 3, 380/415V) 4 -main pole version (4 AC

More information

300% Motor full load amps at 80 seconds, 400% Motor full load amps at 35 seconds

300% Motor full load amps at 80 seconds, 400% Motor full load amps at 35 seconds Digital Soft Start Controls Soft Starters & 9 thru 900 s 208-460V 50/60 Hz. 9 thru 900 s 208-575V 50/60 Hz. Farm Duty Applications: Controlled ramp start and stop, minimize spillage in material handling,

More information

Bulletin 1494F Fixed-Depth Flange-Mounted Disconnect Switches. Selection Guide

Bulletin 1494F Fixed-Depth Flange-Mounted Disconnect Switches. Selection Guide F Fixed-Depth Flange-Mounted Disconnect Switches Selection Guide F Fixed-Depth Flange-Mounted Disconnect Switches Product Cat. No. 1494F-N Disconnect Switch with Cat. No. 1494F-F Fuse Block Adapter Plate

More information

Protectors. 35mm DIN rail snap-on mounting. Wide range of accessories

Protectors. 35mm DIN rail snap-on mounting. Wide range of accessories Manual motor protectors Manual motor protectors Manual motor Protectors MS116 MS32 MS4X MS49X Description Type MS116 Suitable for use with 3-phase motors up to 10 HP @ 480V UL Listed and CSA certified

More information

UL Enclosed Disconnect Switches (Fused and Non-Fused)

UL Enclosed Disconnect Switches (Fused and Non-Fused) Product Selection UL Enclosed Disconnect Switches (Fused and Non-Fused) Catalog Number Explanation 194R-K Non-Metallic Enclosure UL Type 3/4/4X, IP66 194R-F Painted Steel Enclosure UL Type 3/4/12, IP66

More information

SECTION MOTORS, MOTOR STARTERS, VARIABLE FREQUENCY DRIVES AND ELECTRICAL WORK

SECTION MOTORS, MOTOR STARTERS, VARIABLE FREQUENCY DRIVES AND ELECTRICAL WORK PART 1 - GENERAL 1.1 GENERAL: SECTION 15150 MOTORS, MOTOR STARTERS, VARIABLE FREQUENCY DRIVES AND ELECTRICAL WORK A. The Mechanical Contractor shall furnish to the Electrical Contractor for installation,

More information

Application Mini Contactors for Motors and Resistive Loads

Application Mini Contactors for Motors and Resistive Loads Delivery program Contactor, 4p, 4kW/400V/AC3 Part no. DILEM4-G(24VDC) Catalog No. 012701 Eaton Catalog No. XTMF9A00TD Product range Contactors Application Mini Contactors for Motors and Resistive Loads

More information

Short form catalogue. Motor protection & control

Short form catalogue. Motor protection & control Short form catalogue Star Series Motor protection & control Motor Protection and Control up to 25 HP / 600 VAC Overview...2 Contactors and Overload Relays...11 4-pole Contactors...41 Control Relays...59

More information

Approved Standards. Motor Contactor. Main contactor. Accessoires. 21 Motor Contactor J7KN

Approved Standards. Motor Contactor. Main contactor. Accessoires. 21 Motor Contactor J7KN Motor Contactor Main contactor AC & DC operated Integrated auxiliary contacts Screw fixing and snap fitting (35 mm DIN rail) up to 45 kw Range from 4 to 110 kw (AC 3, 380/415V) Finger proof ( VBG 4) Accessoires

More information

FAMILY. 1-Phase 1 Up to 25A Up to 40A Up to 80A Up to 600VAC 3-Phase, 2 leg 1 No Up to 33A Up to 80A Gang 2 units

FAMILY. 1-Phase 1 Up to 25A Up to 40A Up to 80A Up to   600VAC 3-Phase, 2 leg 1 No Up to 33A Up to 80A Gang 2 units THE DIN-A-MITE FAMILY 1 Refer to curves on reverse side for specific ratings. ➁ angle fire is not CE approved for conducted or radiated emissions. ➂ Will fit within the width dimension of most comparable

More information

Instruction Bulletin. Enclosed ALTISTART 46 Controller Supplemental Instruction Bulletin Class 8638 and 8639 INTRODUCTION

Instruction Bulletin. Enclosed ALTISTART 46 Controller Supplemental Instruction Bulletin Class 8638 and 8639 INTRODUCTION Instruction Bulletin Bulletin No. 0006-39-03 May 997 Raleigh, NC, USA Enclosed ALTISTART 6 Controller Supplemental Instruction Bulletin Class 8638 and 8639 INTRODUCTION This bulletin is a supplement to

More information

Power Switching Devices

Power Switching Devices Watlow has manufactured solid state power controllers for over forty years. Watlow s is a microprocessor-based product that features application flexibility unmatched by any other silicon controlled rectifier

More information

These documents contain additional information concerning related products from Rockwell Automation.

These documents contain additional information concerning related products from Rockwell Automation. Additional Resources These documents contain additional information concerning related products from Rockwell Automation. Title PowerFlex 0-Series Drive Installation Instructions PowerFlex 0-Series Programming

More information

Cat. No. 194R-J Note: Your order must include 1) Cat. No. of disconnect switch, 2) shaft, 3) handle, and 4) any accessories.

Cat. No. 194R-J Note: Your order must include 1) Cat. No. of disconnect switch, 2) shaft, 3) handle, and 4) any accessories. Product Selection UL/CSA Fused Disconnect Switches Cat. No. 194R-J30-1753 Cat. No. 194R-J100-1753 Note: Your order must include 1) Cat. No. of disconnect switch, 2) shaft, 3) handle, and 4) any accessories.

More information

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts AF4... AF96 -pole contactors to 6 hp at 48 V AC AC / DC operated with N.O. N.C. auxiliary contacts Description AF4... AF96 contactors are mainly used for controlling -phase motors and power circuits up

More information

HVW701 HVAC Drive with By-Pass

HVW701 HVAC Drive with By-Pass s Automation Energy Transmission & Distribution Coatings HVW701 HVAC with By-Pass Designed Especially for HVAC Systems US.HVW701.By-Pass.07/2017 www.weg.net WEG HVAC-R Products WEG, a leading supplier

More information

Reduced Voltage Starters

Reduced Voltage Starters Reduced Voltage Starters Reduced Voltage Starters- ASTAT XT Soft Starter Description and Features...2-2 Product Number Configuration...2-3 NEMA and IEC Ratings...2-4 Technical Specifications...2-5 Functions...2-6

More information

[V] Common Control Transformer Control (See page 1-78 Note)

[V] Common Control Transformer Control (See page 1-78 Note) Bulletin NEM Combination Non-Reversing Starters Product Selection Circuit Breaker Type NEM Size Continuous mpere Rating [] Bulletin NEM starter sizes Overload relays: Eutectic supplied as standard, solid-state

More information

Synergy EN product information

Synergy EN product information Synergy EN60947-4-2 product information Rated operational voltages U e 200Vac to 480Vac Rated operational currents I e See Rating Table Rating index See Sizing Guide Rated frequency/frequencies 50-60Hz

More information

Varispeed E7. Varispeed E7. Varispeed. Varispeed E7. Varispeed E7. Varispeed E7 INVERTER SERIES

Varispeed E7. Varispeed E7. Varispeed. Varispeed E7. Varispeed E7. Varispeed E7 INVERTER SERIES INVERTER SERIES Varispeed E VARISPEED E YASKAWA INVERTER DRIVE TECHNOLOGY Contents Content Page 2 Experience & Innovation A leader in Drives technology Page 3 Specifications Experience & Innovation For

More information