300% Motor full load amps at 80 seconds, 400% Motor full load amps at 35 seconds
|
|
- Helen Fitzgerald
- 5 years ago
- Views:
Transcription
1 Digital Soft Start Controls Soft Starters & 9 thru 900 s V 50/60 Hz. 9 thru 900 s V 50/60 Hz. Farm Duty Applications: Controlled ramp start and stop, minimize spillage in material handling, reduced water hammer in pumping, reduced wear on mechanical gears, eliminate high inrush current, and energy optimizing of under loaded motors. Typical applications include: pumps, conveyors, fans, reciprocating compressors and screw and rotary compressors Features: Six SCR three phase voltage control with programmable starting ramp and current limit. Application software senses changing load conditions and adapts to increase performance. Power factor optimization eliminates motor over-fluxing and allows under-loaded or over-sized motors to operate more efficiently. NEMA 1 enclosure. Design Specifications MOV protection Current feedback Microprocessor Control Power factor sensing Energy optimization One programmable input Two programmable form C outputs Custom Product Capabilities NEMA 12, 4 or 3R enclosures with bypass contactor Flange mounted input disconnect Input circuit breaker or fuses Input contactor 3 wire start/stop pushbuttons 2 wire Hand-Off-Auto switch Indicating lights Large units up to 1800 amps Environmental and Operating Conditions Input voltage 3 phase V Control voltage 120VAC Input frequency 50/60 Hz Humidity 90% RH condensing 3000 feet altitude 40 C ambient temperature Protective Features Current limit Shorted SCR detection SCR overload Shear pin-over-current detection Low current/under-load detection Input phase loss on start up Heat sink over-temperature Brake 200 & 575 Volt Output Voltage V, V Current 9-900A Horsepower Short Circuit Altitude Derate Voltage and application rated, 5-700Hp 5000 eres symmetrical 1% per 330 feet above 3300 feet Temperature Derate 2% per one C above 40 C up to 60 C Overload Standard Duty 300% Motor full load amps at 35 seconds, 400% Motor full load amps at 6 seconds Input Ratings Control Spec SCR Spec Ambient Conditions Medium Duty Heavy Duty Voltage V, V Frequency Phase Control Method Start Time Stop Time 300% Motor full load amps at 60 seconds, 400% Motor full load amps at 12 seconds 300% Motor full load amps at 80 seconds, 400% Motor full load amps at 35 seconds 50/60 Hz Three Phase Microprocessor controlled full wave, three phase, six thyristor firing Programmable seconds Programmable seconds Voltage Pedestal Programmable: Start 10-60%, Kick 60-90%, Stop 10-60% Current Limit Power Factor Control Power Peak Inverse Voltage Heat Loss 800% of rated current Continuously monitored to eliminate motor over-flux for power optimizing VAC, 50/60 Hz 460VAC controllers 1400V 575VAC controllers 1600V Temperature Enclosed 0-40 C Cooling Altitude 3.3 Watts per 1 ere running current Convection / Forced Air included when required 3300 feet above sea level & Controls DC Soft Starters & 343
2 Farm Duty Brake 200 & 575 Volt Digital Soft Start Controls - Typical Applications Standard Duty Agitator Axial Blower Axial Fan Band Saw Centrifugal Pump Chiller Escalator Low Inertia Fan Propeller Fan Small Pump Medium Duty Circular Saw Conveyor, Screw Feeder Drilling Press Elevator Flywheel Press Grinder Hammer Press High Inertia Fan Large Pump Mill Mixer Pelletizer / Pulper Positive Displacement Pump Reciprocating Compressor Vibrating Screen Soft Starters & Heavy Duty Centrifugal Blower Centrifugal Fan Chipper Disintegrator Loaded Centrifuge Loaded Mixer Loaded Screw Compressor Loaded Reciprocating Compressor Pulverizer Rock Crusher Separator Standard Duty (a) Medium Duty (b) Heavy Duty (c) Cont. Output 208V (d) 230V 460V 208V (d) 230V 460V 208V (d) 230V 460V s Motor Application 10 Starts per hour Maximum MD7-009-CB 1648 E MD7-016-CB 1712 E MD7-023-CB 1884 E MD7-030-CB 2046 E MD7-044-CB 2332 E MD7-059-CB 2613 E MD7-072-CB 2955 E MD7-085-CB 3124 E MD7-105-CB 3766 E MD7-146-CB 4449 E MD7-174-CB 5898 E MD7-202-CB 6545 E MD7-242-CB 7035 E7 2 Motor Application 3 Starts per hour Maximum MD7-300-CB 7841 E MD7-370-CB 8491 E MD7-500-CB E MD7-600-CB E MD7-750-CB E MD7-900-CB E7 3 & Controls DC Soft Start & 344 Standard Duty (a) Medium Duty (b) Heavy Duty (c) Cont. Output 575V 575V 575V s Motor Application 10 Starts per hour Maximum MD8-009-CB 1895 E MD8-016-CB 1969 E MD8-023-CB 2166 E MD8-030-CB 2353 E MD8-044-CB 2681 E MD8-059-CB 3005 E MD8-072-CB 3397 E MD8-085-CB 3592 E MD8-105-CB 4330 E MD8-146-CB 5117 E MD8-174-CB 6781 E MD8-202-CB 7526 E MD8-242-CB 8089 E7 2 Motor Application 3 Starts per hour Maximum MD8-300-CB 8891 E MD8-370-CB 9765 E MD8-500-CB E MD8-600-CB E MD8-750-CB E MD8-900-CB E7 3 (a) 300% Motor 35 Sec., 400% Motor 6 Sec. (b) 300% Motor 60 Sec., 400% Motor 12 Sec. (c) 300% Motor 80 Sec., 400% Motor 35 Sec. (d) 208V applications are UL listed only to 196V.
3 Digital Soft Start Controls - Dimensions Dimensions Soft Starters & Farm Duty Height Outside Width Depth Height Mounting Width Ap x. Shpg. Wgt. lbs. (kg) (420) 8.7 (222) 7.7 (195) 15.7 (400) 5.9 (150) 16.1 (7.3) or 18.3 (8.3) > 44 amp (520) 13.4 (340) 10.4 (265) 19.7 (500) 9.8 (250) 34.5 (15.7) or 48.4 (22) > 200 amp 3 24 (610) 26.6 (675) 15.7 (400) 22.7 (575) 19.7 (500) 143 (65) or (72) > 600 amp Digital Soft Start Controls - Accessories External MOV (Metal Oxide Varistor type voltage surge suppressor) Protects from line-to-line voltage spikes Recommended for all low line impedance applications Volts MOV505L E7 MOV620EL E7 Brake 200 & 575 Volt Remote Keypad with Cable 32 Character English alphanumeric display NEMA 4X indoor enclosure Backlit LCD Cable Length CBLDS015KP 5 ft. 379 E8 Expansion Board Two programmable relay outputs with FORM C contact (normally open and normally closed) Two programmable analog outputs 10mA maximum) One programmable or 4-20mA analog input EB0389A00SP 570 E8 & Controls DC Soft Starters & 345
4 Farm Duty Multipurpose Solid State Soft Starter Soft Starters & 8 thru 420 s 208/230/460V 60 Hz. 8 thru 30 s 208/230/460/575V 60 Hz. Applications: Controlled ramp start and stop, minimize spillage in material handling applications and water hammer in pumping equipment. Current limit provides a current ceiling to limit peak demand on start and constant current starting of high inertial loads such as chippers, centrifuges and compressors. Typical applications include: small and large pumps, conveyors, low and high inertia fans, reciprocating compressors, screw and rotary compressors. Features: Six SCR power devices and several enclosure options.tachometer feedback may be used to provide consistent starting independent of load conditions on textile, material handling and pumping equipment. Brake 200 & 575 Volt & Controls DC Soft Start & Design Specifications Current feedback Microprocessor Control Power factor sensing Energy optimization One programmable input Two programmable form C outputs Programmable current limit Model Control only Output Ratings Input Rating Control Spec. SCR Spec. Protective Functions Ambient Conditions Environmental and Operating Conditions Input voltage 3 phase V Control voltage 120VAC Input frequency 50/60 Hz Humidity 90% RH condensing 3000 feet altitude 40 C ambient temperature Protective Features Current limit Shorted SCR detection SCR overload Shear pin-over-current detection Low current/under-load detection Input phase loss on start up Heat sink over-temperature 208/230/460 VAC 60 Hz. MA7-008-CA MA7-016-CA MA7-030-CA MB7-055-CP MB7-080-CP MB7-160-CP MB7-250-CP MB7-420-CP 208/230/460/575 VAC 60 Hz. MA8-008-CA MA8-016-CA MA8-030-CA 230 VAC Hp Rating 460 VAC VAC Current Rating Overload Rating Continuous 115% of FLA; 400% for 30 seconds Derate Above 1000m (3300 Ft.) decrease amp rating 1% for each additional 100m (330 ft.) Above 45 (115 F) decrease amp rating 1.% for each additional C (0.84%/ F) Frequency 60 Hz. ±5% Voltage +10% to -15% (except for 575 VAC units max. VAC is 620) Phase Three Phase Control Method 6 SCRs connected in inverse parallel for full-wave control Start Time Adjustable 3-50 seconds (current limit starting is not timed) Stop Time Adjustable 5-50 seconds to extend stopping time Initial Torque Adjustable starting 0-75%: Stopping 0-100% Current Limit Adjustable % of full load amps Pulse Time Adjustable seconds Current Monitor Adjustable % of full load amps (causes a contact closure or control shut down when current level is reached after starting) Power Factor Adjustable for max. reduced motor voltage dependent on motor load Control Power Self-powered External Transformer Status Contacts 125 VAC at 0.5 normally open Peak Inverse Voltage 460 VAC Starters 1200 VAC 575 VAC Starters 1600 VAC Heat Loss 3.3 watts per running amp Over Current Over current shut down at 450% of motor full load amps Shorted SCR Detection Shunt trip contact SCR Thermostat Trips on over temperature of heat sink on 55 amp sizes and above Voltage Transient Metal oxide varistor (MOV) Temperature Enclosed 0-45 C (32 to 113 F) open/panel 0 to 50 C (32 to 122 F) Cooling Convection Forced Air 346
5 Multipurpose Solid State Soft Starter Soft Starters & Combination Starter (a) NEMA 12 (can also be used for NEMA 1) MB7-055-GC (b) 5376 E MB7-080-GC (b) 5896 E MB7-160-GC (b) E MB7-250-GC (b) E MB7-420-GC (b) E7 NEMA 1-208/230/460 Volts MB7-080-AB 7140 E MB7-160-AB 9415 E MB7-250-AB E MB7-250-AB E MB7-420-AB E7 Non-Combination Starter (a) NEMA MB7-160-BB 7963 E MB7-250-BB 8860 E MB7-420-BB E7 Control Only Open/Panel MA7-008-CA 1169 E MA7-016-CA 1230 E MA7-030-CA 1443 E MB7-055-CP 2735 E MB7-080-CP 3919 E MB7-160-CP 5100 E MB7-250-CP 6989 E MB7-420-CP 8778 E MA8-008-CA 1220 E MA8-016-CA 1292 E MA8-030-CA 1493 E7 NEMA MB7-160-CB 6196 E MB7-250-CB 8121 E MB7-420-CB 9781 E7 (a) Combination Starter includes control, overload relay and circuit breaker. Non-combination Starter includes control and overload relay. (b) Uses a shunt bypass contactor to short SCR after ramp up (not a full voltage bypass starter). Custom controls available. Farm Duty Brake 200 & 575 Volt Single Phase Starter 7 thru 110 s 115/230V 50/60 Hz. Applications: Use with existing or new magnetic starter. This industrial solid state control will reduce initial starting torque and current of single phase motors allowing them to be started with minimum voltage drop. High starting torque problems such as belt slippage may be eliminated. Ideal for crop driers, augers, bucket elevators and fan or pump applications. & Controls Features: Two adjustable starting torque settings. Adjustable starting ramp time to 30 seconds Notes (a) Open/Panel - 115/230 Volts 7 1/4 3/4 S20CA 495 E /2 2 S21CA 515 E S22CA 550 E S23CA 587 E S25CA 981 E7 19 NOTE: To size single phase starters use the motor FLA. There is a great variation in FLA between motor manufacturers in these sizes. (a) See notes on inside back flap and pages 5-6. DC Soft Starters & 347
6 Farm Duty Soft Start Control Soft Starters & 8 thru 135 s 208/230/460V 60 Hz. 8 thru 30 s 220/380/415V 50 Hz. 8 thru 30 s 575V 60 Hz. Brake 200 & 575 Volt Applications: Use with magnetic starter. Excellent for retrofit on cranes, conveyors or fans. Can be used on single speed, multispeed and reversing, soft starting windmilling fans and soft plug reversing. Features: Two adjustable starting torque settings for reversing or two speed applications. Adjustable ramp time from 2-30 seconds. Open/Panel (Available in NEMA 1 and NEMA 12/3R enclosures) 208 Volt 230 Volt 460 Volt D70CA 829 E D71CA 889 E D72CA 1001 E D73CP 2054 E D74CP 2679 E D75CP 4772 E7 220 Volt 380 Volt 415 Volt D90CA 829 E D91CA 889 E D92CA 1001 E7 575 Volt (can be used at 208/230/460 Volts) 8 5 D80CA 883 E D81CA 935 E D82CA 1042 E7 & Controls DC Soft Start & Three Phase Torque Control 7 thru 40 s 208/230/460V 50/60 Hz. 7 thru 24 s 208/230/460/575V 50/60 Hz. Applications: Use with magnetic starter. A low cost way to reduce starting torque on three phase motors. An alternative to ballast resistors on cranes and conveyors. Suitable for reduced torque on start. Designed to be used with a magnetic contactor. Not suitable for starting high torque loads. Features: Two adjustable starting torque settings for reversing or two speed applications. Adjustable starting ramp time to 7 seconds Open/Panel 208/230/460 Volts T70EA 495 E T71EA 515 E T72EA 550 E T73EA 587 E7 Open/Panel 575 Volts (can be used at 208/230/460 Volts) T80EA 532 E T81EA 550 E T82EA 587 E7 348
7 Multipurpose Dynamic Brake Soft Starters & HP V 50/60 Hz HP V 50/60 Hz Farm Duty Design Specifications Microprocessor based control SCR/Diode power circuit Line contactor Motor voltage sensing circuit Zero speed sensing Four braking time ranges Three operating modes Two adjustable braking magnitude potentiometers Applications: Stopping coasting loads such as chippers, saws, cutting tools and conveyors. It can also be used to stop windmilling fans before starting. Features: The Multipurpose Brake is a microprocessor based solid state brake designed to eliminate the problems common to traditional DC injection brakes. To eliminate blown fuses and welded contacts, the microprocessor senses when AC is no longer present before turning on the braking. A faster zero speed sensing circuit turns off the braking as soon as the motor stops to reduce motor heating. Environmental and Operating Conditions 40 degrees C 1000 feet elevation Open panel design 208, 230, 460, 575 volt input line voltage 50/60 Hz input frequency Control voltage 120 VAC Protective Features Shorted SCR protection Motor terminal voltage sensing Time delay to allow motor flux to collapse Motor starter interlock contact Brake Model 208/230/460 VAC Hz. (a) BQ7-016-CP BQ7-030-CP BQ7-055-CP BQ7-080-CP BQ7-135-CP BQ7-160-CP BQ7-250-CP BQ7-420-CP BQ7-600-CP 230/460/575 VAC Hz. (a) BQ8-016-CP BQ8-030-CP BQ8-055-CP BQ8-080-CP BQ8-135-CP BQ8-160-CP BQ8-250-CP BQ8-420-CP BQ8-600-CP Output 230 VAC Ratings Hp Rating 460 VAC VAC Current Rating Derate Above 1000m (3300 Ft.) decrease amp rating 1% for each additional 100m (330 ft.) Above 45 (115 F) decrease amp rating 1.5% for additional C (0.84%/ F) Input Frequency Hz. ±5% Rating Voltage control board 115 VAC +10% to -15% Phase Three Phase Control Control Type Microprocessor Based Spec. Control Method Common Anode SCR and diode to achieve DC Control Power External control transformer (suppled with certain models) 115 VAC Hz. to the control board Power Consumption 1.5 VA by the control board Operating Modes Master mode (brake controls starting and stopping of motor) Prestop mode (prestop a windmilling load) Basic mode (for replacement of existing dynamic brake) Brake Timer Ranges 1-17 seconds; seconds; seconds; seconds Zero Speed Sensor Selectable (brake disengages when motor stops rotating) M Contact Rating 10 amp at 125 VAC Brake Magnitudes Two adjustable brake magnitudes Status LEDs Power/Ready/Run/Braking Peak Inverse Voltage 460 VAC controls V; 575 VAC controls V Heat Loss 1 watt per amp while braking Diagnostics Error Indicators Improper line voltages; Motor contactor failed to open; Brake contactor failed to open; Improper line frequency Dimensions Height x Width x Depth x x x x 6 21 x 21 x 8 33 x 33 x 9.75 Ambient Conditions Temperature Enclosed 0-45 C (32 to 113 F) open/panel 0 to 50 C (32 to 122 F) (a) For 50 Hz. applications use the brakes without a transformer and supply a separate 115 VAC supply to the brake control board and contactor. The brake can also be ordered as a BQ9 - XXX - XX for 380/400/415 VAC applications. It will have the control transformer mounted on the panel. 200 & 575 Volt & Controls DC Soft Starters & 349
8 Farm Duty Brake 200 & 575 Volt Multipurpose Dynamic Brake Application Notes Soft Starters & Open/Panel BQ7-016-CP 1143 E BQ7-030-CP 1214 E BQ7-055-CP 1601 E BQ7-080-CP 2400 E BQ7-135-CP 3841 E BQ7-160-CP 4507 E BQ7-250-CP 5465 E BQ7-420-CP 7665 E BQ7-600-CP E7 NEMA BQ7-016-CC 1289 E BQ7-030-CC 1360 E BQ7-055-CC 1747 E BQ7-080-CC 2547 E BQ7-135-CC 4158 E BQ7-160-CC 4826 E BQ7-250-CC 5786 E BQ7-420-CC 9398 E BQ7-600-CC E7 Stopping Time The Baldor Dynamic Brake can stop the motor faster than the motor will start (at full volts). However, this could damage the motor. It is best that the motor should not stop any faster than the motor starts. A dynamic brake should never be set to stop a load faster than the load starts. Stopping the motor too fast or too frequently can cause motor overheating and possible failure. Motor Sizing Each stop with a dynamic brake should be treated as a start for calculating duty cycle and for sizing the motor. The brake does not have a duty cycle limit. Holding Brake A solid state brake is not a substitute for a mechanical holding brake. Motor Types The Multipurpose Brake has been designed to operate on 3-phase induction motors. Brake Sizing Use the motor FLA and operating voltage to size the brake. All Baldor Multipurpose Brakes can be used on high inertia loads. Extended stopping times are available for use on high inertia loads. WARNING: A DC injection brake is not a replacement for a mechanical or safety brake for emergency stopping & Controls DC Soft Start & 350 Single Phase Electronic Motor Brake Applications: Efficient alternative to mechanical brakes, suitable for woodworking machinery, machine tools, bench grinders and buffers. Ideal for OEM equipment or for retrofitting into an existing application. Features: Automatic braking for single-phase motors. User adjustable torque and brake time. Prevents restarts after power has been removed for 7 seconds. Accommodates frequent start/stop applications. Available in panel mount for system integration or with line cord, plug and receptacle in a NEMA 1 enclosure for easy installation. Horsepower s Voltage Notes (a) Panel Mount BQ1-015-CP E7 33 BQ2-015-CP E7 33 NEMA 1 BQ1-015-CC E7 33 BQ2-015-CC E7 33 SUFFIX: CP = 6"x5"x3" module without cord, receptacle, switch or enclosure. CC = 8"x8"x4.5" NEMA 1 enclosure with 9ft. cord, receptacle and switch. (a) See notes on inside back flap and pages 5-6.
300% Motor full load amps at 80 seconds, 400% Motor full load amps at 35 seconds
Digital Soft Start Controls 9 thru 900 Amps 208-460V 50/60 Hz. 9 thru 900 Amps 208-575V 50/60 Hz. Applications: Controlled ramp start and stop, minimize spillage in material handling, reduced water hammer
More informationXFE. The cost effective starter for all AC induction motors from 4A 2800A The choice for small to medium industrial applications
The cost effective starter for all AC induction motors from 4A 2800A The choice for small to medium industrial applications The XFE Soft Starter range provides a combination of competitive prices, flexible
More informationRVS-DN Digital Reduced Voltage Motor Starter
RVS-DN Digital Reduced Voltage Motor Starter Specification Guide Specification Guide Contents 1.0 Introduction 2.0 Specifications 2.1 Standard Performance Features 2.2 Standard Protection Features 2.3
More informationFeatures and Benefits. Control Features
Features and Benefits AC induction motors have become increasingly dominant in industrial facilities worldwide. Manufacturers faced with increasing pressure to control costs have recognized that motor
More informationRVS-DX Digital Reduced Voltage Motor Starter
RVS-DX Digital Reduced Voltage Motor Starter Specification Guide Specification Guide Contents 1.0 Introduction 2.0 Specifications 2.1 Standard Performance Features 2.2 Standard Protection Features 2.3
More informationCTi Automation - Phone: Fax: Web:
CTi Automation - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.ctiautomation.net - Email: info@ctiautomation.net The control & protection you expect in an innovative soft starter design... Flexibility
More informationRVS-AX Instruction Manual
RVS-AX Analog Soft Starter 8-170A, 220-600V Instruction Manual Ver. 10/11/2009 2 Table of Content RVS-AX Instruction Manual 1. TABLE OF CONTENT 1. Table of Content...2 2. Safety & Warnings...3 2.1 Safety...3
More informationSoftstarters. Softstarters Type SSM Medium voltage ,800V 1
Medium voltage 2300 13,800V 1 Description Fused disconnect switch with blown fuse indicators and door safety interlocks rated for load break/fault make with automatic grounding arm Inline isolation vacuum
More informationThe Enclosed Altistart 22 Soft Start/Soft Stop Motor Controller
The Enclosed Altistart 22 Soft Start/Soft Stop Motor Controller A pre-engineered solution with an integrated circuit breaker disconnect and an Altistart 22 soft start in a stand-alone enclosure Make the
More informationMaxPak Plus Analog DC V S Drive
Three-Phase 3-600 HP non-regenerative and 5-150 HP regenerative drives Designed to accommodate a wide range of industrial requirements, the DC V S Drive has been widely applied worldwide. Selected ratings
More informationPhoenix DX Sensorless AC Vector Drive. 3 HP to 3500 HP
Phoenix DX Sensorless AC Vector Drive 3 HP to 3500 HP Standard Features: * PRECISE CONTROL OF MOTOR SPEED AND TORQUE * BI-DIRECTIONAL FLYCATCHER (CATCH SPINNING MOTOR) * EASY TO USE, SIMPLE SETUP * POWER
More informationData sheet. CI-tronic Soft start motor controller Type MCI 3, MCI 15, MCI 25, MCI 30 I-O, MCI 50 I-O 520B1443
CI-tronic Soft start motor controller Type MCI 3, MCI 15, MCI 25, MCI 30 I-O, MCI 50 I-O December 2002 DKACT.PD.C50.G2.02 520B1443 2 DKACT.PD.C50.G2.02 Danfoss A/S 12-2002 Introduction The MCI soft starters
More informationCI-Tronic Soft start motor controller MCI 3, MCI 15, MCI 25, MCI 30 I-O, MCI 40-3D and MCI 50-3 I-O
Data sheet CI-Tronic Soft start motor controller MCI 3, MCI 15, MCI 25, MCI 30 I-O, MCI 40-3D and MCI 50-3 I-O The MCI soft starters are designed for soft starting and stopping of 3 phase AC motors, thus
More informationSOLSTART Instruction Manual
Solstart Analog Soft Starter 8-58A, 220-600V Instruction Manual Ver. 23/03/2009 2 Table of Content SOLSTART Instruction Manual 1. TABLE OF CONTENT 1. Table of Content...2 2. Safety & Warnings...3 2.1 Safety...3
More informationFincor Series 2230 MKII/2240
Fincor Series 2230 MKII/ Fincor Series 2200 regenerative drives are ideal for your more demanding applications. They feature flexibility with ratings up to 5 horsepower. The Series 2230 MKII offers new
More informationa revolution in soft start motor control The future of soft start motor control at your fingertips
The future of soft start motor control at your fingertips As the original pioneers of soft start technology Fairford have been at the forefront of motor control innovation since the 1970 s. A major designer
More information2122H. Arm Field Arm Field 1/8-1/ / /8-1/ / / /
Non-Regen Drives Non-regenerative drives are typically used on applications which primarily motor in one direction and stopping is achieved through friction or infrequent use of a dynamic braking resistor.
More informationa revolution in soft start motor control The future of soft start motor control at your fingertips
The future of soft start motor control at your fingertips As the original pioneers of soft start technology Fairford have been at the forefront of motor control innovation since the 1970 s. A major designer
More informationMAKING MODERN LIVING POSSIBLE. Design Guide VLT MCD 100 Soft Starter the single speed drive
MAKING MODERN LIVING POSSIBLE Design Guide VLT MCD 100 Soft Starter the single speed drive Contents Contents 1.1.1 Introduction 2 1.2 Technical Data 3 1.3.1 Functional Diagram 4 1.3.4 Wiring 5 1.3.5 Adjustments
More informationThe future of soft start motor control at your fingertips
Low Voltage Soft Starters a revolution in soft start motor control The future of soft start motor control at your fingertips a revolution in soft start motor control As the original pioneers of soft start
More informationGame changing soft starters
Agile soft starters Low Voltage Soft Starters Game changing soft starters 17 66 A Fire Mode Agile soft starters Soft Stopping Current is limited during soft stopping and gives greater control against water
More informationApplication example of a motor controlled by MCD100 and protected by a circuit breaker
VLT T Soft Start Controller MCD 100 MCD 100 is a cost effective and extremely compact soft starter for AC motors up to 11 kw. Due to a unique semiconductor design MCD 100 is a true fit and forget product.
More informationDesign Guide. VLT Soft Start Controller MCD 100
Design Guide VLT Soft Start Controller MCD 100 Introduction The MCD 100 soft starters are designed for soft starting and stopping of 3 phase a.c. motors, thus reducing the inrush current and eliminating
More informationFincor DC Drives. Flexible & Powerful TYPICAL APPLICATIONS. Conveyor Rugged. Extruder Reliable. Conveyor Simple. Mixer Flexible
DC Drives Flexible & Powerful single-phase DC drives provide a complete family solution from the compact Series 2120 chassis drive to the powerful Series 2230 and it s feature rich application specific
More informationRegenerative DC Common Bus Supply
Regenerative DC Common Bus Supply The Regenerative DC Common Bus Supply supplies both motoring and regenerative current to the DC bus of one or more AC drives without the need of rectifier front end in
More informationDimensions WxHxD [mm] Weight [kg]
SPECIFICATIONS The SOLSTART electronic soft starter incorporates two sets of thyristors (Two phase control) to start a threephase squirrel cage induction motor and an internal bypass. By supplying a slowly
More informationStandard Features 200-600V, 50/60Hz input power supply Built-in run rated (AC1) By-pass contactor up to 820 A * Rated 450% current Conformal coated circuit board Voltage ramp or current limit start modes
More informationA flexible, reliable and affordable drive for 1/4 through 2 HP DC applications
A flexible, reliable and affordable drive for 1/4 through 2 HP DC applications DC2 drives combine application flexibility, compact size and reliability into an affordable adjustable speed package that
More informationThe Z Series. SCR Power controllers for resistance heating applications. Zero-Fired SCR Power Controllers AMPS VAC
The Z Series Zero-Fired SCR Power Controllers 60-1200 AMPS 120-600 VAC SCR Power controllers for resistance heating applications. ROBICON 1996 Rev. 7/96 Applications Robicon s Z series power controls are
More informationSensorless Vector Drives
STANDARD PRODUCTS Sensorless Vector Drives SG SERIES STANDARD DUTY / HEAVY DUTY RATINGS Variable Torque: 7.5 to 700HP @ 460V 7.5 to 40HP @ 2V Standard Duty: 7.5 to 600HP @ 460V 7.5 to 40HP @ 2V Heavy Duty:
More informationSINUS PENTA 2T/4T SINUS PENTA 2T/4T
SINUS PENTA 2T/4T SINUS PENTA 2T/4T Technical Highlights One product, 5 integrated functions - IFD (Inverter Frequency Drive): vector modulation function for general-purpose applications (V/F pattern).
More informationSECTION MOTOR CONTROL
SECTION 26 24 19 MOTOR CONTROL PART 1 - GENERAL 1.1 SECTION INCLUDES A. Manual motor starters B. Magnetic motor starters C. Combination magnetic motor starters D. Solid-state reduced voltage motor starters
More informationMCD 200 Series Soft Starters
MCD 200 Series Soft Starters AC motors often cause one or more serious problems during startup acceleration. MCD 200 Series electronic soft starters control motor current to provide a smooth start. When
More informationNEMA 1, NEMA 4X and Chassis Mount Adjustable Speed Controls for DC Motors
Made in the U.S.A. NEMA 1, NEMA 4X and Chassis Mount Adjustable Speed Controls for DC Motors Nema Enclosed DC Control Specifications Catalog Number BC140 or Features BC138 BC139 BC140-FBR BC154 BC160 BCWD140
More informationDENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION MOTORS, STARTERS & DRIVES
PART 0 DESIGN STANDARDS 0.01 GENERAL DESIGN GUIDELINES A. Coordinate starter needs for mechanical equipment prior to 50% CD and confirm again for 100% CD submittal. B. Coordinate temperature controls requirements
More information1/2 thru 1.5 Hp 1/2 thru 3 Hp 2 thru 5 Hp 1 thru 10 Hp
VS1MX AC Micro Drive 1/2 thru 1.5 Hp 1/2 thru 3 Hp 2 thru 5 Hp 1 thru 10 Hp & Controls 115 VAC 230 VAC 230 VAC 460 VAC 1 Phase - 50/60 Hz 1 Phase - 50/60 Hz 3 Phase - 50/60 Hz 3 Phase - 50/60 Hz Applications:
More informationA. Provide variable frequency drives to operate variable torque loads as shown on the Drawings and as specified herein.
DIVISION 23 HEATING, VENTILATING, AND AIR CONDITIONING (HVAC) SECTION 23 90 71 PART 1 GENERAL 1.01 DESCRIPTION A. Provide variable frequency drives to operate variable torque loads as shown on the Drawings
More informationAIR COOLED RECTIFIER SPECIFICATION S-50-A
SPECIFICATIONS AIR COOLED RECTIFIER Spec50a1 5JAN1999 SPECIFICATION S-50-A HIGH VOLTAGE SINGLE TRANSFORMER AIR COOLED RECTIFIER Standard output power range: 250 to 600 volts at 100 to 1,200 amperes TECHNICAL
More informationControl Power V AC, 50/60 Hz 150-C30NBD 150-C30FHD
Bulletin Product Selection Open Type and Non-Combination Enclosed (IP, NEMA /) Controllers For use with Line-Connected Motors Rated Voltage [V AC] / Motor Current [A]...... Max. kw, Hz Max. Hp, Hz Control
More informationVS1PFB 230V, 50/60 Hz, 3-Phase
Farm Duty Unit Handling Brake 200 & 575 Volt Pump and Fan Bypass AC Drive 7.5 thru 40 Hp 7.5 thru 125 Hp & Controls 230 VAC 460 VAC 3 Phase - 50/60 Hz 3 Phase - 50/60 Hz Applications: Pump and Fan AC Drive
More informationSSW03 Soft Starter APG2009.indd 69 5/26/09 8:55 AM
www.we.net WEG are built to match the ruedness and reliability of WEG motors, providin a complete and cost effective solution. Full microprocessor based control allows easy adjustment throuh the keypad
More informationABB Softstarter Benefits Charnchanok Thongprad
ABB Softstarter Benefits Charnchanok Thongprad tomation Technology Products AB Control - 1 - - Why Softstarters? Benefits for the Electrical network Reduces voltage drops on networks Minimizes starting
More information1.2. Reduced Voltage Motor Starters. Contents Description Type S611, Soft Starters... Type S801+, Soft Starters. Type S801+, Soft Starters
Reduced Voltage Motor Starters.2 Type S80+, Soft Starters Contents Type S6, Soft Starters..................... Type S80+, Soft Starters Operation.............................. Features...............................
More information1.2. Reduced Voltage Motor Starters. Contents Description Type S611, Solid-State Soft Starters... Type S801+, Soft Starters. Solid-State Starters
.2 Type S80+, Soft Starters Contents Description Type S6, Solid-State Soft Starters........... Type S80+, Soft Starters Operation............................. Features.............................. Benefits...............................
More informationGPH2 Combination Soft Starters
Combination Soft Starters The Combination Soft Starter is a NEMA 4/12 Enclosed industrial general purpose AC motor soft starter package. It is designed for simple and quick installation and start-up, requiring
More informationCI-tronic Soft Start Motor Controller Type MCI 25B with Brake
Data sheet CI-tronic Soft Start Motor Controller Type MCI 25B with Brake MCI 25B motor controller with brake is designed for soft starting and braking of 3 phase AC motors. The digital controlled soft
More informationGPH2. Soft Starters. Applications. Standard Features. Centrifugal Pumps Screw Compressors Centrifugal Fans Wood Chipper Veneer Lathe Saw Conveyor
The Combination Soft is a NEMA 4/12 Enclosed industrial general purpose AC motor soft starter package. It is designed for simple and quick installation and start-up, requiring only input power and output
More informationA. Danfoss VLT Soft Starter The single speed drive. For any soft start situation MAKING MODERN LIVING POSSIBLE
MAKING MODERN LIVING POSSIBLE Danfoss VLT Soft Starter The single speed drive 3 1600 A For any soft start situation VLT Soft Starters cover the full range from simple start-stop operation to high end performance.
More informationTemperature Controllers
Controllers SCR Power Controllers Introduction to Silicon Controlled Rectifier (SCR) Power Controllers Features and Benefits of SCRs High reliability Because the SCR power controller is a solid-state device,
More informationTemperature Controllers
SCR Power Controllers Introduction to Silicon Controlled Rectifier (SCR) Power Controllers Features and Benefits of SCRs High reliability Because the SCR power controller is a solid-state device, it provides
More informationSoftstarters Type PSS. Softstarters. General information
General information The PSS Softstarter line brings a wide array of benefits for smaller motors in a flexible, compact form. The PSS "Flexible" Softstarter line PSS18/30 to PSS300/515 softstarters provide
More informationSteve Schouten. Donna Densmore
March 12, 2013 2 Steve Schouten Donna Densmore 3 Mike Carter Justin Kale 4 Basics Motor Loads Operation Advantages/ Disadvantages Sizing a VFD Power Quality Issues Source: Emerson Industrial Automation
More informationChapter 8. Understanding the rules detailed in the National Electrical Code is critical to the proper installation of motor control circuits.
Chapter 8 Understanding the rules detailed in the National Electrical Code is critical to the proper installation of motor control circuits. Article 430 of the NEC covers application and installation of
More informationApplications: Conveyors, machine tools and other applications requiring adjustable speed. Mult. Sym.
HVAC Farm Duty Fractional Horsepower DC Speed Controls for PMDC DC & Controls 1/15 thru 1/4 115 VAC Single Phase 50/60 Hz. Applications: Conveyors, machine tools and other applications requiring adjustable
More informationMOTORTRONICS Solid State AC Motor Control
Solid State AC Motor Control MWH Series Solid State Motor Winding Heater 10 to 80 Amps INSTALLATION & START-UP MANUAL REV 4 6091101MN Table of Contents Chapter 1: General Information... 1 1.1 Introduction
More informationATevo SERIES BATTERY CHARGER
PRODUCT OVERVIEW NEXT GENERATION NEW FEATURES: Interactive LCD display Intelligent self diagnostics NERC Compliant ATevo Battery Charger is the next generation SCR-based utility battery charger. The innovative
More informationApplication Description
-14 Type, Intelligent Technologies (IT.) Soft Starters February 2007 Contents Description Page Type, Intelligent Technologies (IT.) Soft Starters Product Description....... -14 Application Description....
More informationAT EVO SERIES BATTERY CHARGER
STANDARD FEATURES 5 YEAR WARRANTY EVO AT Series Battery Charger is HindlePower s next generation SCR-based utility battery charger. This evolutionary product is revolutionary in its design and operation
More informationSoftstarters. Softstarters Power electronic brakes Type PEB
Softstarters Power electronic brakes Softstarters Description Electronic braking stops the load by injecting a controlled amount of DC current into a three phase AC motor. The Power Electronic Brake (PEB)
More informationSECTION MOTORS, MOTOR STARTERS, VARIABLE FREQUENCY DRIVES AND ELECTRICAL WORK
PART 1 - GENERAL 1.1 GENERAL: SECTION 15150 MOTORS, MOTOR STARTERS, VARIABLE FREQUENCY DRIVES AND ELECTRICAL WORK A. The Mechanical Contractor shall furnish to the Electrical Contractor for installation,
More informationSIRIUS Soft Starters Introduction
Introduction Overview Products at a glance 3RW30/3RW31 3RW40 3RW44 Class 73/74 Enclosed 16 CONTROL SIRIUS soft starters for standard applications SIRIUS 3RW30 soft starters SIRIUS 3RW40 soft starters for
More informationDescription 1/8-7.5HP
Description 1/8-7.5HP J1000 In our pursuit to create drives optimized for variable speed needs in compact applications, the J1000 is the solution. This micro-drive is simple and reliable with Yaskawa quality.
More informationA Compact, Liquid-Cooled Variable Speed Drive for High Horsepower Applications
A Compact, Liquid-Cooled Variable Speed Drive for High Horsepower Applications The Reliance Electric LiquiFlo AC drive combines high-performance variable speed drive technology with a patented liquid-cooling
More information1/2 thru 1.5 Hp 1/2 thru 3 Hp 2 thru 5 Hp 1 thru 10 Hp
VS1MX AC Micro Drive 1/2 thru 1.5 Hp 1/2 thru 3 Hp 2 thru 5 Hp 1 thru 10 Hp & Controls 115 VAC 230 VAC 230 VAC 460 VAC 1 Phase - 50/60 Hz 1 Phase - 50/60 Hz 3 Phase - 50/60 Hz 3 Phase - 50/60 Hz Applications:
More informationWARRANTY INFORMATION...
Table of contents 1 General Information... 3 1.1 Description... 3 1.2 Features... 3 1.3 Specifications... 4 1.4 Receiving and Unpacking... 4 1.5 Dimensions... 4 2 Installation... 5 2.1 Wiring... 5 3 Operation...
More information150 B180 N B D A 8L. Enclosure Type. Input Line Voltage Open Type V AC, 3-phase, 50 and 60 Hz V AC, 3-phase, 50 and 60 Hz
Catalog Number Explanation Open Controllers a Bulletin Number Solid-State Controller B H H B B B B B B B B B B B B B Solid-State Controller and Isolation Contactor (enclosed only) b Controller Ratings
More informationBurden Fuse Rating Resistor SAF / SAK6 1NM 10mm M8 12NM SAF / SAK10 2NM 16mm M8 12NM
Contents Section Page 1.0 Introduction 1 2.0 Specification 1-4 3.0 Installation 5-8 4.0 Programming 9-10 5.0 Menus 10-12 6.0 Fault Finding/Diagnostics 12-13 7.0 Communication 13 8.0 Setting Up 13-16 1.0
More informationPCS compact soft starters
PCS compact soft starters Soft starting solutions with integrated motor protection. MOTOR CONTROL AND DRIVES Myriad Pro Condensed 12 pt Capitals White NHP Electrical Engineering Products AUS NZ 1300 NHP
More informationProduct Description. Application Description
-2 Solid-State Controllers Type TL, Torque Limiter August 6 Contents Description Page Torque Limiters............ -2 Soft Start Controllers........ -4 Soft Start Controllers with Auxiliary Contact.....
More informationVariable Speed Drives Controlling Centrifugal Pumps Energy Savings
2018 Clean and Safe Drinking Water Workshop Hotel Gander Variable Speed Drives Controlling Centrifugal Pumps Energy Savings Presenter: Dave Galbraith What is a Variable Speed (Frequency) Drive? AKA VFD,
More informationA. Danfoss VLT Soft Starter The single speed drive. For any soft start situation
MAKING MODERN LIVING POSSIBLE Danfoss VLT Soft Starter The single speed drive 3 1600 A For any soft start situation VLT Soft Starters cover the full range from simple startstop operation to high end performance.
More informationGuide to the Application of Soft Starters
FAIRFORD ELECTRONICS Guide to the Application of Soft Starters APPLICATIONS GUIDELINES FOR THE QFE, QFE PLUS AND STARTMASTER SOFT STARTERS This bulletin tries to answer many of the common questions which
More informationEPS-ECONOMY PUMP STARTER
EPS-ECONOMY PUMP STARTER NEMA 1 & 3R ENCLOSURES franklinwater.com EPS-ECONOMY PUMP STARTER - 1 & 3 PHASE, 50/60HZ, 200-600 VAC, 1-80A The enhanced Franklin Electric Economy Pump Starter (EPS) provides
More informationCatalog # D Catalog # TD Catalog # TD Catalog # AS. Mult. Sym. Shpg. Wgt.
Industrial Abrasive Belt Sanders offers several options when it comes to industrial belt sanders, fixed and tiltable belts, grinder/sanders and even an adjustable speed sander for increased flexibility.
More informationSALDET SALES & SERVICE, INC. CLINTON TOWNSHIP, MICHIGAN
Form 1254 BRAKETRON Electronic Motor Brake Instructions SALDET SALES & SERVICE, INC. CLINTON TOWNSHIP, MICHIGAN TABLE OF CONTENTS SECTION TITLE PAGE I. Introduction 1 II. Specifications 1 III. Principles
More information1/6 through 5 HP Adjustable Speed, DC Motor Controllers
1/6 through 5 HP Adjustable Speed, DC Motor Controllers 1/6-5 HP 115 or 230 V, Single Phase - Reconnectable Four Quadrant Regenerative Selectable Deadband AC Line Starting DC Tachometer Feedback Run Contact
More informationPSE The efficient range Description
Description The PSE softstarter range is the world s first compact softstarters with Torque Control. This makes the PSE range an excellent choice for pumping application where water hammering normally
More informationVariable Speed Product Line
Variable Speed Product Line BRCPVFD R1 Variable Speed Product Line Since 1997, CentriPro has been providing variable speed pump control solutions to its customers. The first product was the Aquavar variable
More informationVariable Frequency Drives
We Make Energy Engaging Variable Frequency Drives Questline Academy Meet Your Panelist Mike Carter questline.com 2 Contents Basics Motor Loads Operation Advantages/ Disadvantages Sizing a VFD Power Quality
More informationAquavar SPD Plus SIMPLEX VARIABLE SPEED SUBMERSIBLE AND ABOVE GROUND PUMP CONTROLLER BRSPDP R2
SIMPLEX VARIABLE SPEED SUBMERSIBLE AND ABOVE GROUND PUMP CONTROLLER BRSPDP R2 SPD Plus Do you want to simplify your commercial pumping system and save energy? CentriPro SPD Plus variable speed, constant
More informationMotors Automation Energy Transmission & Distribution Coatings. GPH2 Combination Soft Starters
Motors Automation Energy Transmission & Distribution Coatings GPH2 Combination Soft Starters GPH2 Combination Soft Starter 5to 350 HP The Combination Soft Starter is a NEMA 4/12 Enclosed industrial general
More informationteam master medium voltage solid state starters
team master medium voltage solid state starters The Today s global economy is in many ways driven by the AC Induction Motor. Industrial facilities worldwide depend on these motors to drive the machinery
More informationCI-tronic Soft starters for Danfoss commercial compressor applications Type MCI 15C, MCI 25C, MCI 50CM-3 I-O
Data sheet CI-tronic Soft starters for Danfoss commercial compressor applications Type, MCI 25C, MCI 50CM-3 I-O The MCI compressor soft starters are designed for soft starting of 3 phase compressors. During
More informationAn Engineering Guide to. Soft Starters
An Engineering Guide to Soft Starters Contents 1 Introduction 5 1.1 General 5 1.2 Benefits of soft starters 5 1.3 Typical Applications 6 1.4 Different motor starting methods 7 1.5 What is the minimum
More informationCT430 - Soft Starters on Motor Applications
CT430 - Soft Starters on Motor Applications Bill Bernhardt Sr. Commercial Engineer May 16, 2018 PUBLIC Copyright 2018 Rockwell Automation, Inc. All Rights Reserved. 1 Topics Traditional Motor Starting
More informationAxpert-CSS AMTECH DRIVES Axpert-CSS Amtech
The Axpert-CSS is a range of Combination Soft Starter panels offered by AMTECH DRIVES. We also offer the module unit as an individual product, named as Axpert-Opti torque Soft Starter. This is only the
More informationReduced Voltage Motor Starters
Reduced Voltage Motor Starters Soft Start Controllers. Solid-State Controllers Product Overview........................................ Type S70, Soft Start Controllers............................. Type
More informationHVW701 HVAC Drive with By-Pass
s Automation Energy Transmission & Distribution Coatings HVW701 HVAC with By-Pass Designed Especially for HVAC Systems US.HVW701.By-Pass.07/2017 www.weg.net WEG HVAC-R Products WEG, a leading supplier
More informationDRAFT 1400HP 1000HP 100HP. Reduced Voltage Solid State Starters. Softstarters SOFT. PF Controller PCS Controller PDS Controller V 1...
100HP 400HP 700HP 1000HP 1400HP PCS Softstarter Controller IN-rail mountable microprocessor controller for 3-phase motors up to 480A (3...85A din-rail mountable) Provides three different starting modes
More informationBRSDRIVE ITT. Goulds Pumps. S-Drive. Simplex Variable Speed Submersible Pump Controller. Engineered for life
ITT BRSDRIVE Goulds Pumps Simplex Variable Speed Submersible Pump Controller C U L US Engineered for life Do you want to Simplify your Commercial Pumping System? Goulds Pumps S-Drive variable speed, constant
More informationAT30 SERIES BATTERY CHARGER
STANDARD FEATURES 5 YEAR WARRANTY 5 Year Product Warranty Universal main control board operates in any AT Series charger Alarm assembly with local LEDs and summary relay contact for AC Failure, DC Failure,
More informationReduced Voltage Starters Section 2
Reduced Voltage Starters- ASTAT XT Soft Starter Description and Features...2-2 Product Number Configuration...2-3 NEMA and IEC Ratings...2-4 Technical Specifications...2-5 Functions...2-6 Overload Protections,
More informationMotor Starters. Reduced Voltage. Reduced Voltage Motor Starters Contents
June 5 Vol. 2, Ref. No. [067] -1 Reduced Voltage Motor Starters Contents Description Page Solid-State Controllers Type S701, Soft Start.......................................... -2 Type TL, Torque Limiter........................................
More informationOpen Chassis Star-Delta Starter User Guide
Open Chassis Star-Delta Starter User Guide (7.5kW~90kW) V2.0.1 Contents 1 Safety information... 1 2 Technical Data... 2 3 Supply & Motor Connections & Circuit Diagrams... 5 4 Control Connections & Operation...
More informationEVO AT SERIES BATTERY CHARGER
EVO AT SERIES BATTERY CHARGER AT SERIES BATTERY CHARGER P R O D U C T PATENT PENDING hindlepowerinc.com 610-330-9000 Evo AT Series battery charger designed with YOU in mind. Evo AT Series battery charger
More informationFAMILY. 1-Phase 1 Up to 25A Up to 40A Up to 80A Up to 600VAC 3-Phase, 2 leg 1 No Up to 33A Up to 80A Gang 2 units
THE DIN-A-MITE FAMILY 1 Refer to curves on reverse side for specific ratings. ➁ angle fire is not CE approved for conducted or radiated emissions. ➂ Will fit within the width dimension of most comparable
More informationSoftstarters Softstarters
, PSS & PST(B), PSS & PST(B) Low Voltage Products & Systems 6.1 General information PSR PSS From the moment the first electrical motors appeared, engineers have been searching for a way to avoid electrical
More informationHp V AC Current Rating [A] 230V AC 60 Hz
Product Selection/Options Open Type Controllers Up to V AC kw Hp V AC Current Rating [A] V AC Hz V AC Hz V AC Hz V AC Hz V AC Hz / Hz Control V AC/DC Control.. -BNBD -BNBR. -BNBD -BNBR -BNBD -BNBR -BNBD
More informationStarting Torque Limiter Type TCI (Soft Start)
Data sheet Starting Torque Limiter Type TCI (Soft Start) Starting Torque Limiters are designed for the soft starting of single and tree phase AC motors. The controller allows smooth starting of all AC
More informationCódigo de rotor bloqueado Rotor bloqueado, Letra de código. Rotor bloqueado, Letra de código
Letra de código Código de rotor bloqueado Rotor bloqueado, Letra de código kva / hp kva / hp A 0.00 3.15 L 9.00 10.00 B 3.15 3.55 M 10.00 11.00 C 3.55 4.00 N 11.00 12.50 D 4.00 4.50 P 12.50 14.00 E 4.50
More information