Presentation Soft starters 0 Altistart 48 soft start - soft stop units
|
|
- Shawn Mason
- 5 years ago
- Views:
Transcription
1 Presentation Soft starters _Ver.-EN.fm/
2 Presentation (continued) Soft starters Applications The Altistart 8 soft start - soft stop unit is a controller with 6 thyristors which is used for the torque-controlled soft starting and stopping of three-phase squirrel cage asynchronous motors in the power range between and kw. It offers soft starting and deceleration functions along with machine and motor protection functions as well as functions for communicating with control systems. These functions are designed for use in state-of-the-art applications in centrifugal machines, pumps, fans, compressors and conveyors, which are primarily to be found in the construction, food and beverages and chemical industries. The highperformance algorithms of the Altistart 8 contribute significantly to its robustness, safety and ease of setup. The Altistart 8 soft start - soft stop unit is a cost-effective solution which can: # Reduce machine operating costs by reducing mechanical stress and improving machine availability # Reduce the stress placed on the electrical distribution system by reducing line current peaks and voltage drops during motor starts The Altistart soft start - soft stop unit offer comprises ranges: # Three-phase voltages to 5 V, 5/6 Hz # Three-phase voltages 8 to 69 V, 5/6 Hz In each voltage range, the Altistart soft start - soft stop units are dimensioned for standard and severe applications. Functions The Altistart 8 soft start - soft stop unit ( ) is supplied ready for use in a standard application with motor protection class (see page 656/5). It comprises a built-in terminal ( ) which can be used to modify programming, adjustment or monitoring functions in order to adapt and customise the application to meet individual customer requirements. # Drive performance functions: 5 Exclusive Altistart torque control (patented by ) 5 Constant control of the torque supplied to the motor during acceleration and deceleration periods (significantly reducing pressure surges) 5 Facility for adjusting the ramp and the starting torque 5 The starter can be bypassed using a contactor ( ) at the end of the starting period whilst maintaining electronic protection (bypass function) 5 Wide frequency tolerance for generator set power supplies 5 The starter can be connected to the motor delta terminals in series with each winding # Machine and motor protection functions: 5 Built-in motor thermal protection 5 Processing of information from PTC thermal probes 5 Monitoring of the starting time 5 Motor preheating function 5 Protection against underloads and overcurrents during continuous operation # Functions facilitating the integration of the unit into control systems: 5 logic inputs, logic outputs, relay outputs and analogue output 5 Plug-in I/O connectors 5 Function for configuring a second motor and easy-to-adapt settings 5 Display of electrical values, the state of the load and the operating time 5 RS 85 serial link for connection to Modbus Options A remote terminal ( ) can be mounted on the door of a wall-fixing or floor-standing enclosure. PowerSuite advanced dialogue solutions: # PowerSuite Pocket PC with PPC type terminal ( 5 ), # PowerSuite software workshop ( 6 ). A range of wiring accessories for connecting the starter to PLCs via a Modbus connection ( 7 ). Bus communication and Ethernet, Fipio, DeviceNet and Profibus DP network communication options Characteristics: pages 65/ to 65/5 pages 65/ to 65/5 pages 65/ to 65/5 pages 65/ to 65/7 65_Ver.-EN.fm/
3 Characteristics Soft starters Environment Conformity to standards The electronic starters have been developed and performance tested in accordance with international standards, in particular with the starter product standard EN/IEC &marking Products have CE marking in accordance with the harmonised standard EN/IEC Product approvals UL, CSA Pending: DNV, C-Tick, Ghost, CCIB Degree of protection Starters ATS 8D7/ to 8C/ IP (IP in the absence of connections) Starters ATS 8C/ to 8M/ IP () Vibration resistance Conforming to IEC mm from to Hz gn from to Hz Shock resistance Conforming to IEC g for ms Starter noise level () Starters ATS 8D/ to D7/ dba 5 Starters ATS 8D6/ to C/ dba 58 Starters ATS 8C/ to C7/ dba 5 Starters ATS 8C/ to C/ dba 5 Starters ATS 8C/ to C66/ dba 55 Starters ATS 8C79/ to M/ dba 6 Fans Starters ATS 8D7/ and D/ Natural convection Starters ATS 8D/ to M/ Forced convection. The fans are activated automatically when a temperature threshold is reached. For flow rate see page 65/5. Ambient temperature around the unit Operation C without derating (between + and + 6, derate the nominal current of the Altistart by % for each C). Storage, conforming to C IEC Maximum relative humidity Conforming to IEC % without condensation or dripping water Maximum ambient pollution Conforming to IEC 666- Level Maximum operating altitude m without derating (above this, derate the nominal current of the Altistart by.% for each additional m). Limit to m. Operating position Maximum permanent angle in relation to the normal vertical mounting position Electrical characteristics Operating category Conforming to IEC AC-5a Three-phase supply voltage Starters ATS 8///Q V -5% to 5 + % Starters ATS 8///Y V 8-5% to 69 + % Frequency Hz 5/6 ± 5% (automatic) 5 or 6 ± % (must be set) Nominal starter current Starters ATS 8///Q A 7... Starters ATS 8///Y A 7 to Motor power Starters ATS 8///Q kw to 6 Starters ATS 8///Y kw/hp 5.5 to 9/5 to Voltage indicated on the motor rating plate Starters ATS 8///Q V to 5 Starters ATS 8///Y V 8 to 69 Starter control circuit supply voltage Starters ATS 8///Q V - 5% to 5 + %, 5/6 Hz Starters ATS 8///Y V - 5% to + %, 5/6 Hz Maximum control circuit consumption (with fans operating) Relay output ( configurable outputs) Starters ATS 8D7/ to C7/ W Starters ATS 8C/ to C/ W 5 Starters ATS 8C/ to M/ W 8 relay outputs (R, R, R), normally open contacts "N/O" Minimum switching capacity: ma for $6 V. Maximum switching capacity on inductive load:.8 A for " V and $ V (cos ϕ=.5 and L/R=ms). Maximum nominal operating voltage " V. Factory setting: R assigned as the "fault relay" (configurable) R assigned as the "end of starting relay" to control the starter bypass relay R assigned as "motor powered" (configurable) () Protective covers can be fitted to the power terminals of ATS 8C/ to C/ starters. ATS 8C/ to 8M/ starters have protection on the front panel and on the sides. () Starters located m away. The noise levels may change depending on the characteristics of the fans. pages 65/ and 65/ pages 65/ to 65/5 pages 65/ to 65/5 pages 65/ to 65/7 65_Ver.-EN.fm/
4 Characteristics (continued) Soft starters Electrical characteristics (continued) Logic inputs LI ( configurable inputs) logic inputs, impedance. kω, isolated: Stop, Run, LI, LI. + V power supply (maximum V) I max. 8 ma State if U < 5 V and I < ma State if U > V and I > 5 ma Internal source available x + V output, isolated and protected against short-circuits and overloads. Accuracy ± 5%. Max. current ma. Logic outputs LO (configurable) logic outputs LO and LO with V common, compatible with level PLC, according to standard IEC 65A V power supply (minimum: + V, maximum: + V). Maximum output current: ma if supplied externally Analogue output AO (configurable) Current output - ma or - ma Maximum load impedance: 5 Ω Accuracy ± 5% of the maximum value Input for PTC probe Total resistance of probe circuit 75 Ω at 5 C, according to IEC 6 78-A Maximum I/O connection capacity.5 mm (AWG ) Communication RS 85 multidrop serial link integrated in the starter, for Modbus, with RJ5 type connector Transmission speed 8, 96 or 9 bps Maximum number of Altistart 8 connected: 8 Other uses: - connection to a remote terminal or - connection to a PC or - connection to other buses and networks via communication options. Protection Thermal Built-in, starter and motor (calculated and/or thermal protection with PTC probes) Line protection Phase failure, indicated by output relay Current settings The nominal motor current In can be adjusted from. to. times the starter nominal current. Adjustment of the maximum starting current from.5 to 7 times the motor In, limited to 5 times the starter nominal current. Starting mode By torque control with starter current limited to 5 In maximum. Factory setting: In for standard operation on 5 s torque ramp Stopping mode Freewheel stop "Freewheel" stop (factory setting) Controlled stop on torque ramp Programmed between.5 and 6 s (for pump applications) Braked stop Controlled dynamically by the flux Electromagnetic compatibility EMC () Standards Test levels Examples (sources of interference) Summary of immunity tests carried out with the Altistart 8 IEC 6-- level Electrostatic discharge: - by contact - in the air IEC 6-- level Radiated electromagnetic fields IEC 6-- level Rapid electrical transients: - power supply cables - control cables IEC 6--5 level Shock wave: - phase/phase - phase/earth IEC 6-- level Damped oscillating waves 6 kv 8 kv Contact off an electrically charged individual V/m Equipment transmitting radio frequencies kv kv kv kv Opening/closing of a contactor Oscillating circuit on the line supply kv - M Hz Radiated and conducted emissions According to IEC 697--, class A, on all starters According to IEC 697--, class B, on starters up to 7 A: ATS 8D7/ to 8C7/. Must be bypassed at the end of starting () The starters conform to product standard IEC 697--, in particular with regard to EMC. This standard ensures a level of immunity for products and a level of emitted interference. In steady state, the interference emitted is below that required by the standard. During acceleration and deceleration phases, low level loads may be affected by low frequency interference (harmonics). To reduce this interference, connect chokes between the line supply and the Altistart 8 (see page 658/). Note: # Power factor correction capacitors can only be used upstream of the Altistart and only powered up at the end of starting. # The starter must be earthed to conform to the regulations concerning leakage currents (6 ma). When the use of an upstream "residual current device" for protection is required by the installation standards, an A-Si type device must be used. Check its compatibility with the other protective devices. If the installation involves several starters on the same line supply, each starter must be earthed separately. - pages 65/ and 65/ pages 65/ to 65/5 pages 65/ to 65/5 pages 65/ to 65/7 65_Ver.-EN.fm/
5 Characteristics (continued) Soft starters Torque characteristics Curves indicating changes in the torque depending on the starting current of a threephase asynchronous motor. Curves : direct line starting Curves : starting in current limiting mode Torque curve Ts indicates the total torque range available depending on the limiting current Is. Limiting the starting current Is to a preset value Is will reduce the starting torque Ts to a value which is almost equal to the square of currents Is/Is. Example: For motor characteristics: Ts = Tn for Is = 6 In, limit the current to Is = In (.5 Is) resulting in a starting torque Ts = Ts x (.5)² = Tn x.5 =.75 Tn Starting current Direct line starting current Starting current limited to Is I/In 6 5 Id,5,5,75 Starting torque Direct line starting torque Starting torque with current limited to Is C/Cn 6 5 Cd Cr,5,5,75 pages 65/ and 65/ pages 65/ to 65/5 pages 65/ to 65/5 pages 65/ to 65/7 65_Ver.-EN.fm/
6 Characteristics (continued) Soft starters Conventional starting using current limitation or voltage ramp With current limitation Is, the accelerating torque applied to the motor is equal to the motor torque Ts minus the resistive torque Tr. The accelerating torque increases in the starting range as the speed changes and is at its highest at the end of acceleration (curve ). This characteristic means that the load is taken up very abruptly, which is not recommended for pump type applications. Example of speed curve for starting with current limitation Current applied to the motor (I/In) Motor speed I/In,5 Starting with the Altistart 8 Example of speed curve for starting with torque control Current applied to the motor (I/In) Motor speed Torque control on the Altistart 8 applies the torque to the motor during the entire starting phase if the current required (curve ) does not exceed the limiting current. The accelerating torque can be virtually constant over the entire speed range (curve ). It is possible to set the Altistart in order to obtain a high torque on starting for a rapid motor speed rise whilst limiting its temperature rise, and a lower accelerating torque at the end of starting for gradual loading. This control function is ideal for centrifugal pumps or for machines with high resistive torque on starting. I/In t,5 Stopping with the Altistart 8 # Freewheel stop: the motor comes to a freewheel stop. # Decelerated stop: this type of stop is ideal for pumps and can be used to effectively reduce pressure surges. Torque control on the Altistart 8 reduces the effect of hydraulic transients even if the load increases. This type of control makes adjustment easy. # Braked stop: this type of stop is suitable for high inertia applications as it reduces the stopping time of the machine. t pages 65/ and 65/ pages 65/ to 65/5 pages 65/ to 65/5 pages 65/ to 65/7 65_Ver.-EN.fm/5
ATS22D88Q soft starter-ats22-control 220V-power 230V (22kW)/ V(45kW)
Product datasheet Characteristics ATS22D88Q soft starter-ats22-control 220V-power 230V (22kW)/400...440V(45kW) Complementary Assembly style Function available Supply voltage limits Main Range of product
More informationAltistart 48 Y-Range Soft Start Controllers Installation Guide
Altistart 48 Y-Range Soft Start Controllers Installation Guide Instruction Bulletin 30072-450-61B Retain for future use. For Use in North America 30072-450-61B Altistart 48 Y-Range Soft Start Controllers
More informationSOLSTART Instruction Manual
Solstart Analog Soft Starter 8-58A, 220-600V Instruction Manual Ver. 23/03/2009 2 Table of Content SOLSTART Instruction Manual 1. TABLE OF CONTENT 1. Table of Content...2 2. Safety & Warnings...3 2.1 Safety...3
More informationRVS-AX Instruction Manual
RVS-AX Analog Soft Starter 8-170A, 220-600V Instruction Manual Ver. 10/11/2009 2 Table of Content RVS-AX Instruction Manual 1. TABLE OF CONTENT 1. Table of Content...2 2. Safety & Warnings...3 2.1 Safety...3
More informationThe Enclosed Altistart 22 Soft Start/Soft Stop Motor Controller
The Enclosed Altistart 22 Soft Start/Soft Stop Motor Controller A pre-engineered solution with an integrated circuit breaker disconnect and an Altistart 22 soft start in a stand-alone enclosure Make the
More informationDimensions WxHxD [mm] Weight [kg]
SPECIFICATIONS The SOLSTART electronic soft starter incorporates two sets of thyristors (Two phase control) to start a threephase squirrel cage induction motor and an internal bypass. By supplying a slowly
More informationRVS-DN Digital Reduced Voltage Motor Starter
RVS-DN Digital Reduced Voltage Motor Starter Specification Guide Specification Guide Contents 1.0 Introduction 2.0 Specifications 2.1 Standard Performance Features 2.2 Standard Protection Features 2.3
More informationVariable speed controllers for asynchronous motors
Contents Presentation, functions Page 14 Characteristics Pages 15 to 18 References Page 18 Options Page 19 Accessories : Braking resistors Page 20 Line chokes Page 21 Dimensions Pages 22 and 2 Schemes
More informationSoft starters ATS 01. Catalogue May
ATS 0 Catalogue May 07 General contents Altistart 0 Altistart U0 Contents 0 - Altistart 0 soft starters b Presentation........................................ pages / and / b Characteristics......................................
More informationApplication example of a motor controlled by MCD100 and protected by a circuit breaker
VLT T Soft Start Controller MCD 100 MCD 100 is a cost effective and extremely compact soft starter for AC motors up to 11 kw. Due to a unique semiconductor design MCD 100 is a true fit and forget product.
More informationAltistart 01 soft starters
Altistart 01 soft starters for single-phase and three-phase ecatalog 2014 Contents Introduction...4 Altistart 01 products...4 ATS01N1 soft starters...6 ATS01N2 & ATSU01N2 soft starters...8 Specifications...12
More informationRVS-DX Digital Reduced Voltage Motor Starter
RVS-DX Digital Reduced Voltage Motor Starter Specification Guide Specification Guide Contents 1.0 Introduction 2.0 Specifications 2.1 Standard Performance Features 2.2 Standard Protection Features 2.3
More informationStarts, stops and protects. Emotron TSA Softstarter
Starts, stops and protects Emotron TSA Softstarter First in a new line of CG high performance softstarters Emotron TSA softstarters take motor control to a new level. Soft torque starting, intelligent
More informationSoftstarter Intelligent Controllers
Softstarter Intelligent Controllers Series Modes of Operation (Standard) Soft Start 100% Percent Voltage Initial Torque Start Run This method has the most general application. The motor is raised from
More informationDelta Products VFD CP2000 Bypass Control Packages.
Delta Products VFD CP2000 Bypass Control Packages www.deltaww.com Delta Products VFD CP2000 Bypass Control Packages The Delta Products VFD CP2000 Bypass Control Packages are designed for the Delta Products
More informationUnidrive M400 Fast set-up and diagnostics with real-text display, integrated PLC and safety inputs
Unidrive M400 Fast set-up and diagnostics with real-text display, integrated PLC and safety inputs 0.25 kw - 110 kw (0.33 hp - 150 hp) 100 V 200 V 400 V 575 V 690 V Unidrive M400 features Optional AI-485
More informationSmartVFD HVAC FEATURES APPLICATION SPECIFICATION DATA
SmartVFD HVAC APPLICATION The SmartVFD HVAC is a variable frequency drive designed for use in HVAC application to control the speed of HVAC pumps and fans in order to maximize energy efficiency. Smart
More informationSD700FR. Regenerative Active Front End VARIABLE SPEED DRIVES POWER ELECTRONICS / SD700 SERIES 4 QUADRANT. icool
FR VARIABLE SPEED DRIVES Regenerative Active Front End icool 4 QUADRANT POWER ELECTRONICS / SD700 SERIES FR SD700FR SERIES goes one step ahead keeping the family unique characteristics. Based on the latest
More informationLH4 Modular Soft Start
File 867 CATALOG CONTENTS Description...Page General Information... Characteristics... 4-5 References... 6 Dimensions and Mounting... 7-8 Recommended Wiring Schemes... 9-11 List of Recommended Components...
More informationwww. ElectricalPartManuals. com Instruction Bulletin ALTIVAR FLEX58 TRX Adjustable Speed Chassis Drive Controllers Installation Guide
Instruction Bulletin ALTIVAR FLEX58 TRX Adjustable Speed Chassis Drive Controllers Installation Guide Retain for future use. 30072-450-47A July 2002 Raleigh, NC, USA HAZARDOUS VOLTAGE Read and understand
More information1.1 Caution Statements
USER MANUAL 1.1 Caution Statements Caution Statements cannot cover every potential cause of equipment damage but can highlight common causes of damage. It is the installer's responsibility to read and
More informationMCD 200 Series Soft Starters
MCD 200 Series Soft Starters AC motors often cause one or more serious problems during startup acceleration. MCD 200 Series electronic soft starters control motor current to provide a smooth start. When
More informationMAKING MODERN LIVING POSSIBLE. Design Guide VLT MCD 100 Soft Starter the single speed drive
MAKING MODERN LIVING POSSIBLE Design Guide VLT MCD 100 Soft Starter the single speed drive Contents Contents 1.1.1 Introduction 2 1.2 Technical Data 3 1.3.1 Functional Diagram 4 1.3.4 Wiring 5 1.3.5 Adjustments
More informationSoft Starter. Types RSBD. Product Description. Type Selection. Ordering Code RSB D E V 61 HP
Soft Starter Three-Phase Scroll Compressor Soft Starter Types RSBD Soft starting of 3-phase scroll compressors up to 95Amp Patented auto-adaptive algorithm for optimum inrush current reduction (No user
More informationDesign Guide. VLT Soft Start Controller MCD 100
Design Guide VLT Soft Start Controller MCD 100 Introduction The MCD 100 soft starters are designed for soft starting and stopping of 3 phase a.c. motors, thus reducing the inrush current and eliminating
More informationRange : 7.5kW to 630/800kW
Range : 7.5kW to 630/800kW ATS 48 PRESENTATION Altistart 48 is a high performance soft starter using 6 thyristors for controlled starting of 3 phase asynchronous squirel cage induction motors. It provides
More information150 B180 N B D A 8L. Enclosure Type. Input Line Voltage Open Type V AC, 3-phase, 50 and 60 Hz V AC, 3-phase, 50 and 60 Hz
Catalog Number Explanation Open Controllers a Bulletin Number Solid-State Controller B H H B B B B B B B B B B B B B Solid-State Controller and Isolation Contactor (enclosed only) b Controller Ratings
More informationControl Power V AC, 50/60 Hz 150-C30NBD 150-C30FHD
Bulletin Product Selection Open Type and Non-Combination Enclosed (IP, NEMA /) Controllers For use with Line-Connected Motors Rated Voltage [V AC] / Motor Current [A]...... Max. kw, Hz Max. Hp, Hz Control
More informationLow voltage AC drives. ABB micro drives ACS to 3 hp/0.18 to 2.2 kw Catalog
Low voltage AC drives ABB micro drives ACS55 0.25 to 3 hp/0.18 to 2.2 kw Catalog ACS55 IP20 Overview ACS55 micro drives are designed for use in a wide variety of simple machinery applications where only
More informationDEVICE STATE/BYPASSED FAILURE OVERLOAD
Technical specifications Type 5. 7. Control electronics Rated values Terminal Rated control supply voltage A1A2 V AC 115 230 115 230 Tolerance % -15+10-15+10 Rated control supply STANDBY ma 15 15 Rated
More informationDatasheet. Pitch Motor PMSM SP260B8
Pitch Motor PMSM SP260B8 Permanent Magnet Compact and light weight High peak torque Excellent efficiency Maintenance free, No fan 5 year warranty Document no.: 4121260012a 1 Application The Pitch motor
More informationData sheet. CI-tronic Soft start motor controller Type MCI 3, MCI 15, MCI 25, MCI 30 I-O, MCI 50 I-O 520B1443
CI-tronic Soft start motor controller Type MCI 3, MCI 15, MCI 25, MCI 30 I-O, MCI 50 I-O December 2002 DKACT.PD.C50.G2.02 520B1443 2 DKACT.PD.C50.G2.02 Danfoss A/S 12-2002 Introduction The MCI soft starters
More informationCI-Tronic Soft start motor controller MCI 3, MCI 15, MCI 25, MCI 30 I-O, MCI 40-3D and MCI 50-3 I-O
Data sheet CI-Tronic Soft start motor controller MCI 3, MCI 15, MCI 25, MCI 30 I-O, MCI 40-3D and MCI 50-3 I-O The MCI soft starters are designed for soft starting and stopping of 3 phase AC motors, thus
More informationCI-tronic Soft Start Motor Controller Type MCI 25B with Brake
Data sheet CI-tronic Soft Start Motor Controller Type MCI 25B with Brake MCI 25B motor controller with brake is designed for soft starting and braking of 3 phase AC motors. The digital controlled soft
More informationDatasheet. Pitch Motor PMSM SP190C8
Pitch Motor PMSM SP190C8 Permanent Magnet Compact and light weight High peak torque Excellent efficiency Maintenance free, No fan 5 year warranty Document no.: 4121260007a 1 Application The Pitch motor
More informationMedium Voltage Soft Starters MOTOR CONTROL IS OUR NATURE
Medium Voltage Soft Starters MOTOR CONTROL IS OUR NATURE hrvs-dn General This advanced, micro-processor controlled through fiber optic links, Medium Voltage soft starter is designed for use with standard
More informationYour choice for wall and panel mounted AC drives. Emotron FDU & Emotron VFX IP20/21 up to 160 kw
Your choice for wall and panel mounted AC drives Emotron FDU & Emotron VFX IP20/21 up to 160 kw A clean and robust mechanical design with few circuit boards and internal electrical connections ensures
More informationDatasheet. Pitch Motor PMSM SP190F8
Pitch Motor PMSM SP190F8 Permanent Magnet Compact and light weight High peak torque Excellent efficiency Maintenance free, No fan 5 year warranty Document no.: 4121260009c 1 Application The Pitch motor
More informationALTIVAR 18 AC Drives. File 8805
ALTIVAR 18 AC Drives File 8805 CATALOG CONTENTS Description....................................................Page Introduction........................................................ 1 Specifications....................................................
More informationApplication Description
-14 Type, Intelligent Technologies (IT.) Soft Starters February 2007 Contents Description Page Type, Intelligent Technologies (IT.) Soft Starters Product Description....... -14 Application Description....
More informationHigh performance Vector Control. Ratings. System configuration
System configuration High performance Vector Control Low harmonic or regenerative drive IP54 full range Compact design and robustness Built-in filter (according to C3 class) Built-in fuses (from 200 kw)
More informationINTER PLANT STANDARD STEEL INDUSTRY NO CORRESPONDING IS
INTER PLANT STANDARD STEEL INDUSTRY SOFT STARTER FOR VOLTAGE UP TO 690 V AC IPSS: 1-10-040-15 IPSS NO CORRESPONDING IS 0. FOREWORD 0.1 This interplant standard has been prepared by the Standard Committee
More informationStandard Features 200-600V, 50/60Hz input power supply Built-in run rated (AC1) By-pass contactor up to 820 A * Rated 450% current Conformal coated circuit board Voltage ramp or current limit start modes
More informationMotor Controllers AC Semiconductor Motor Controller Type RSHP Flexy
otor Controllers AC Semiconductor otor Controller Type RSHP Flexy Soft starting and stopping of 3-phase squirrel cage motors Low surge and vibration-free starting User-selected ramping profiles Integral
More informationINSTALLATION INSTRUCTIONS FOR SYMCOM'S MODEL 777-HVR-SP ELECTRONIC OVERLOAD RELAY
CONNECTIONS INSTALLATION INSTRUCTIONS FOR SYMCOM'S MODEL 777-HVR-SP ELECTRONIC OVERLOAD RELAY BE SURE POWER IS DISCONNECTED PRIOR TO INSTALLATION!! FOLLOW NATIONAL, STATE AND LOCAL CODES! READ THESE INSTRUCTIONS
More informationNEW The new PROmax power supplies offer a wide range of robust solutions for demanding application requirements.
Datasheet Single- and three-phase switched-mode power supply units NEW The new power supplies offer a wide range of robust solutions for demanding application requirements. C SEMI F47 US Designed for high
More informationAltivar 31 AC Drives. Simply Smart! For 3-phase asynchronous motors from 0.25 to 20 HP
Altivar 31 AC Drives Simply Smart! For 3-phase asynchronous motors from 0.25 to 20 HP T A complete offer: Wide choice of voltage ranges Single-phase 208 to 240 V. 3-phase 208 to 240 V. 3-phase 400 to 460
More informationALTIVAR 58 AC Drives
Class 8806 / 8839 / 8998 CONTENTS Schneider Electric Brands Page ALTIVAR 58 AC Drives............................................... 3 Drives Overview...................................................
More informationUnidrive M700 Class leading performance with onboard real-time Ethernet
Unidrive M Class leading performance with onboard real-time Ethernet. kw -.8 MW Heavy Duty (. hp -, hp) V V V 9 V Unidrive M features Easy click-in keypad connection Range of multi-language LCD keypads
More information720 W / 24 V On-board Battery Charger. for industrial applications. Product Data Sheet
for industrial applications Product Data Sheet 720 W / 24 V On-board Battery Charger for industrial applications Features IP65 protection degree Battery selection via GUI, supporting all leading battery
More informationDATASHEET - DILMC9-10(24VDC) Technical data General. Contactor, 3p+1N/O, 4kW/400V/AC3. Catalog No Eaton Catalog No. XTCEC009B10TD.
DATASHEET - DILMC9-10(24VDC) Technical data General Contactor, 3p+1N/O, 4kW/400V/AC3 Part no. DILMC9-10(24VDC) Catalog No. 277468 Eaton Catalog No. XTCEC009B10TD EL-Nummer 4110305 (Norway) Standards IEC/EN
More information2.3. Adjustable Frequency Drives. Contents. Standards and Certifications
Contents Selection................ Product Selection....................... Accessories........................... Technical Data and Specifications.......... Dimensions........................... Page
More informationStarting Torque Limiter Type TCI (Soft Start)
Data sheet Starting Torque Limiter Type TCI (Soft Start) Starting Torque Limiters are designed for the soft starting of single and tree phase AC motors. The controller allows smooth starting of all AC
More informationILA2D572TC1F0 integrated drive ILA with servo motor V - DeviceNet - indus connector
Characteristics integrated drive ILA with servo motor - 24..48 V - DeviceNet - indus connector Main Range of product Product or component type Device short name Motor type Number of motor poles 6 Phase
More informationSINUS PENTA 2T/4T SINUS PENTA 2T/4T
SINUS PENTA 2T/4T SINUS PENTA 2T/4T Technical Highlights One product, 5 integrated functions - IFD (Inverter Frequency Drive): vector modulation function for general-purpose applications (V/F pattern).
More informationat a reduced size!...
Telemecanique Altivar 11 Real efficiency at a reduced size!... Altivar 11 variable speed drives for asynchronous motors from 0.18 to 2.2 kw Building a New Electric World Altivar 11 : The little one with
More informationAltistart 22 soft start/soft stop units
Altistart Catalog 00 Courtesy of Steven Engineering, Inc.-0 Ryan Way, South San Francisco, CA 00-0-Main Office: (0) -00-Outside Local Area: (00) -00-www.stevenengineering.com Courtesy of Steven Engineering,
More informationBurden Fuse Rating Resistor SAF / SAK6 1NM 10mm M8 12NM SAF / SAK10 2NM 16mm M8 12NM
Contents Section Page 1.0 Introduction 1 2.0 Specification 1-4 3.0 Installation 5-8 4.0 Programming 9-10 5.0 Menus 10-12 6.0 Fault Finding/Diagnostics 12-13 7.0 Communication 13 8.0 Setting Up 13-16 1.0
More informationHp V AC Current Rating [A] 230V AC 60 Hz
Product Selection/Options Open Type Controllers Up to V AC kw Hp V AC Current Rating [A] V AC Hz V AC Hz V AC Hz V AC Hz V AC Hz / Hz Control V AC/DC Control.. -BNBD -BNBR. -BNBD -BNBR -BNBD -BNBR -BNBD
More informationSola/Hevi-Duty S3K Series Mini-Tower UPS
Sola/Hevi-Duty S3K Series Mini-Tower UPS GUIDE SPECIFICATIONS 700VA to 1600VA 120V models Single - Phase Uninterruptible Power Supply Systems 1.1 SUMMARY 1.0 GENERAL This specification defines the electrical
More informationSoft starters Altistart 01 The starting solution
Soft starters Altistart 01 The starting solution For single-phase and 3-phase asynchronous motors from 0.37 to 75 kw / 3 to 85 A. Altistart 01 Welcome to the Simply Smart* world, compliments of Telemecanique...
More informationJC-VSD FP Series II Drives Product Bulletin 1
JC-VSD FP Series II Drives Product Bulletin Code No. LIT-12012081 Issued May 2017 The Johnson Controls VSD FP Series II provides the advanced technology and features of the Johnson Controls VSD Series
More informationQuick guide. Plug-in fans GPPM with FC101_106 August 2014
Quick guide Plug-in fans GPPM with FC101_106 August 2014 Fläkt Woods permanent magnet motors and speed controllers for plug fans GPPM 1. General Fläkt Woods offers a wide range of permanent magnet motors
More informationSoftstarters Softstarters
, PSS & PST(B), PSS & PST(B) Low Voltage Products & Systems 6.1 General information PSR PSS From the moment the first electrical motors appeared, engineers have been searching for a way to avoid electrical
More informationReduced Voltage Motor Starters
Reduced Voltage Motor Starters Soft Start Controllers. Solid-State Controllers Product Overview........................................ Type S70, Soft Start Controllers............................. Type
More informationA. Danfoss VLT Soft Starter The single speed drive. For any soft start situation MAKING MODERN LIVING POSSIBLE
MAKING MODERN LIVING POSSIBLE Danfoss VLT Soft Starter The single speed drive 3 1600 A For any soft start situation VLT Soft Starters cover the full range from simple start-stop operation to high end performance.
More informationVariable speed drives for asynchronous motors 0
Presentation Altivar 56250 2 3 4 5 6 7 8 60250-EN_Ver..fm/2 Schneider Electric Presentation (continued) Altivar Characteristics: pages 6025/2 to 6025/5 Schneider Electric References: pages 60252/2 to 60252/5
More informationEaton 93PS 8-40kW UPS Technical Specification Manufacturer s declaration in accordance with IEC
Manufacturer s declaration in accordance with 8- Frame Model catalogue reference 93PS-XX(20)-YY- 93PS-XX(40)-YY- Number of power modules (UPM) 1 1 or 2 Number of internal batteries 0 to 2 x 32 blocks 0
More informationSSW07. Soft Starters. Applications. Standard Features
General Information CFW10 CFW100 CFW08 CFW500 CFW700 CFW701 CFW11 EDP11 CFW11M SSW05 SSW06 GPH2 TPH2 are static starting devices, designed for the acceleration, deceleration and protection of the three
More informationIndustrial PFC UPS System
Based on Statron s leading A.T.I.S. (Advanced Technology Industrial System) platform, the S3000 range is a true-industrial UPS system using the latest Power Factor Corrected (PFC) IGBT rectifier technology.
More informationINVEOR "Smart connections." on five levels
INVEOR "Smart connections." on five levels 1 The Inveor 3 Operation and observation IP65 protection class Integrated soft PLC Pre-fitted cable glands Fan-free design up to 7.5 kw Robust and vibration-resistant
More informationLR9 F OVERLOAD RELAYS
Issued November 2009 DATA SHEET LR9 F OVERLOAD RELAYS Based on Schneider MKTED2050EN Catalogue General 6 Motor protection Operating conditions There are many possible causes of electric motor failure.
More informationVariable speed drives Altivar 78. Catalogue May
Catalogue May 05 Contents 0 for asynchronous motors 1 b Presentation................................................ page 2 b Dialogue................................................... page 4 b v Characteristics.............................................
More informationProduct Description. Application Description
-2 Solid-State Controllers Type TL, Torque Limiter August 6 Contents Description Page Torque Limiters............ -2 Soft Start Controllers........ -4 Soft Start Controllers with Auxiliary Contact.....
More informationVLT Soft Starter MCD 100, MCD 201, MCD 202, MCD 3000
VLT Soft Starter MCD 100, MCD 201, MCD 202, MCD 3000 Soft starts Protect Gear, Goods, Equipment and Environment An AC motor switched directly on to the mains power supply will struggle to reach its nominal
More informationCATALOG. ABB micro drives ACS55, 0.18 to 2.2 kw
CATALOG ABB micro drives ACS55, 0.18 to 2.2 kw 2 ABB MICRO DRIVES, ACS55, 0.18 TO 2.2 KW/0.25 TO 3 HP Ease of integration. ACS55 drives. 3 Table of contents 004 ABB micro drives, ACS55 005 Easily integrated
More informationSoft starters Altistart 01 The starting solution
Soft starters Altistart 01 The starting solution For single-phase and 3-phase asynchronous motors from 0.37 to 75 kw /3to85A. Altistart 01 Welcome to the Simply Smart* world, compliments of Telemecanique...
More informationMotor Starters. Reduced Voltage. Reduced Voltage Motor Starters Contents
June 5 Vol. 2, Ref. No. [067] -1 Reduced Voltage Motor Starters Contents Description Page Solid-State Controllers Type S701, Soft Start.......................................... -2 Type TL, Torque Limiter........................................
More informationILE2K661PC1A1 brushless dc motor V- EtherNet/IP interface - L = 174 mm- 18:1
Characteristics brushless dc motor 24..48V- EtherNet/IP interface - L = 174 mm- 18:1 Main Range of product Product or component type Device short name Motor type Number of motor poles 6 Network number
More informationLow voltage AC drives
General machinery drives Main features and dimensions Unique features Fast and extensive I/O PID control Application macros Many installation possibilities 200 to 480 V, 1-phase or 3-phase More value for
More informationPowerdrive FX Ultra compact regenerative drive solution
Powerdrive FX Ultra compact regenerative drive solution 22 kw - 90 kw (30 hp - 125 hp) 400 V 480 V Powerdrive FX Drives with dynamic braking Based on innovative C-Light 4 Quadrant technology, the variable
More informationVariable Speed Drives Controlling Centrifugal Pumps Energy Savings
2018 Clean and Safe Drinking Water Workshop Hotel Gander Variable Speed Drives Controlling Centrifugal Pumps Energy Savings Presenter: Dave Galbraith What is a Variable Speed (Frequency) Drive? AKA VFD,
More informationHigh Performance, High Function System Drive SOFTSTARTER SS7. 2.2kW ~ 1.5MW / 230 ~ 690V. Drive Solution
rive Solution igh Performance, igh Function System rive SOFTSTARTER SS7 2.2k ~ 1.5M / 230 ~ 690V Features and functions >> Optimized Solution for high performance drive 2.2k - 1.5M / 230 - Optimized motor
More informationOutput Current Input Current Reflected Ripple. Efficiency (typ.) (Range) VDC VDC ma ma(typ.) ma(typ.) ma(typ.) VDC μf % MTQZ50-72S05
Doc. EC-0094 FEATURES Industrial Standard Quarter Brick Package Wide Input Range 43-101VDC & 66-1VDC Excellent Efficiency up to 92% I/O Isolation 3000VAC with Reinforced Insulation Operating Ambient Temp.
More informationLiebert Hipluse U UPS;80-400kVA; 380/400/415V Detailed Specification
Liebert Hipluse U UPS;80-400kVA; 380/400/415V Detailed Specification Conformity And Standard General safety requirements for UPS EMC requirements for UPS Table 1-1 Conformity and standard Normative reference
More information1SVC F SVC F 0607 R100.20/30 R100.45
SIGMASWITCH Content Solid state relays Description, certificates, approvals... 163 Ordering details... 164 Technical data R111, R12x... 167 Technical data R100... 168 Technical data HDS R2... 169 Selection
More informationDocument: PRODSPEC-140 Revision: G DCN No Date: October 1, 2014 Product: 10-amp EnerGenius NRG Battery Charger
Document: PRODSPEC-140 Revision: G DCN No. 106512 Date: October 1, 2014 Product: 10-amp EnerGenius NRG Battery Charger 1. GENERAL DESCRIPTION 1.1 General Description Fully regulated, constant voltage,
More informationUnidrive M600 High performance drive for induction and sensorless permanent magnet motors
Unidrive M600 High performance drive for induction and sensorless permanent magnet motors 0.75 kw - 2.8 MW Heavy Duty (1.0 hp - 4,200 hp) 200 V 400 V 575 V 690 V Unidrive M600 features Easy click-in keypad
More informationLED Driver Linear / area dimming
Driver LC W 0 1050mA 50V IOTr lp PRE UNV PREMIUM series SELV (US applications) Product description Constant current LED Driver Dimming range 1 100 % Adjustable output current between 0 and 1,050 ma via
More informationModel Number Structure
Solid State Relays (Single-phase) G3PB New Single-phase Solid State Relays with Compact Size for Heater Control Slim models with a thickness of only 22.5 mm are also available. Compact design achieved
More informationOutput Current Input Current Over Load VDC VDC ma ma(typ.) ma(typ.) VDC μf %
Doc. EC-0093 FEATURES Industrial Standard 2"x1" Package Ultra-wide Input Range 9-36VDC, 18-75VDC, 40-160VDC I/O Isolation 3000VAC with Reinforced Insulation Operating Ambient Temp. Range -40 C to +88 C
More informationSize for Size Best Value in the Industry
Size for Size Best Value in the Industry Overview for SMC -Flex and SMC -3 Soft ers 3...480A 200-460VAC...500-575VAC www.klinkmann.com Allen-Bradley Smart Motor Controllers... Providing Unmatched Intelligent
More information825-P Modular Protection System for motors Specification Guide
Specification Guide 1.0 General 1.01 The motor protection relay shall have a current operating range of 0.5 and 5000 amperes. 1.02 The motor protection relay shall provide current measurement-based protection
More informationDRIVE THE WATER CYCLE. January 10 TH 2013
DRIVE THE WATER CYCLE January 10 TH 2013 DRIVE THE WATER CYCLE EXTENDED FLOW CONTROLS Throttling control Bypass control Parallel Pump control VSD control THROTTLING CONTROL The operation point is modified
More informationRE48AML12MW time delay relay 2 functions s..300 h V AC - 2 OC
Characteristics time delay relay 2 functions - 0.02 s..300 h - 24..240 V AC - 2 OC Main Range of product Product or component type Electrical connection Discrete output type Contacts type and composition
More informationwww.ic-electronic.com Soft starter with integrated Motor Protection, Current and Voltage control Single phase controlled with internal by-pass ated operational Voltage 230VAC Frequency 45... 65Hz Self
More informationA. Danfoss VLT Soft Starter The single speed drive. For any soft start situation
MAKING MODERN LIVING POSSIBLE Danfoss VLT Soft Starter The single speed drive 3 1600 A For any soft start situation VLT Soft Starters cover the full range from simple startstop operation to high end performance.
More informationFeatures. LED Driver. RACT09 9 Watt. TRIAC Dimmable. Single Output RACT09- AC/DC Converter
Features TRIAC Dimmable LED Driver Triac dimmable with leading or trailing edge dimmers Class II with SELV output (no earth required) Extra-large screw terminals and integrated cable clamps for easy installation
More informationMSC VAC. Variable Speed Drive. Proudly 100% Australian Owned Australian Manufacturers & Distributors of Variable Speed Drives & Soft Starters
MSC - 3 1100VAC Variable Speed Drive Proudly 100% Australian Owned Australian Manufacturers & Distributors of Variable Speed Drives & Soft Starters Why Variable Speed Drive? Process automation & productivity
More informationSolid State Relays contactor with Integrated Fuse Type RGC1F
Solid State Relays contactor with Integrated Fuse Type RGC1F Solid State Contactor with integrated fuse Zero Cross Switching Operational voltage: 230 VAC and 600 VAC 35mm width Control voltage: 4-32 VDC
More information