XLR-8 EXTENDED RACK ACCESSORIES AND PARTS CATALOG
|
|
- Louisa Adams
- 5 years ago
- Views:
Transcription
1 XLR-8 EXTENDED RACK ACCESSORIES AND PARTS CATALOG Catalog part number Rev 1, August, 2018
2 Accessories and Supplies Tray XLR-8 SP7025 Z-Axis Drive Assembly PEEK Anti Kink SP7171 For use with Carbon Fiber and Ultem Probes (PEEK Drive Cable-Green) *Guide plate included for use with probes other than Carbon Fiber versions, typically Ultem Z-Axis Drive Tubing Replacement Kit (PEEK Anti- Kink) SP7174 Sample Probes Length: 10 inches (25.4 cm) Probe Material: FEP-covered carbon fiber Capillary Material: PFA ID (mm) Band Capillary Length Part Number 0.3 Black 108 in (2.74 m) SP5799C 0.5 Blue 108 in (2.74 m) SP5800C 0.8 Red 108 in (2.74 m) SP5796C 0.9 Yellow 70 in (1.78 m) SP5950C Blue 108 in (2.74 m) SP6013C Sample Racks 90 Position, 13.3 mm Round opening, used with 8mL round bottom or 7mL flat bottom vial 90 Position, 13.5 mm Square opening, used with 8mL round bottom or 7mL flat bottom vial
3 60 Position, 17.0 mm Square opening, used with 14mL or 15mL vial 40 Position, 20.6 mm Square opening, used with 20mL vial 24 Position, 25.2 mm Square opening, used with 30mL vial 21 Position, 30.5 mm Square opening, used with 50mL vial Vials 7mL, 13mm x 82mm (1000/kit) 7mL, 13mm x 82mm (250/kit) (Flat bottom with cap) 8mL, 13mm x 100mm (1000/kit) 8mL, 13mm x 100mm (250/kit) (Round bottom without cap) 14mL, 16mm x 100mm (1000/kit) 14mL, 16mm x 100mm (250/kit) 15mL, 17mm x 100mm (1000/kit) 15mL, 17mm x 100mm (250/kit) 20mL, 21.5mm x 100mm (500/kit) 20mL, 21.5mm x 100mm (100/kit) 30mL, 25mm x 95mm (500/kit) 50mL, 30mm x 115mm (500/kit) 50mL, 30mm x 115mm (100/kit) SP5178A SP5178E SP5178K SP5178L SP5178B SP5178F SP5178M SP5178N SP5178G SP5178I SP5178H SP5178C SP5178J Material for all vials is polypropylene Z-Drive Attachment Kit SP5903 3
4 Thumbscrew and O-ring Kit SP5919 Y-Axis Slider Block (Home Block) Hardware Kit SP5918 Drain Pump Tubing and Connector Kit (PharMed) SP6089 Drain Pump Tubing and Connector Kit (Tygon) SP6090 4
5 Repair Parts Rotor Assembly SP6346 Rinse Station SP5337 Rinse Station Block SP5340 X-Axis Drive Belt SP5222 Pump Motor Kit SP7002A 2-Channel 5
6 Carriage Stepper Ribbon Cable-31 (For use with Two-Piece Shield and Splashguard Kit) SP6378 Two-Piece Shield and Splashguard Kit SP6377 Switch / Power Input (6 pin input) SP6104 Power Cable XLR-8 Base to Autosampler Head SP Volt Power Supply (Standard ASX-520) 28-Volt Power Supply (Standard ASX-520HS) SP6103 SP7020 Power Cords US Version Euro Version UK Version Australian Version SP5003 SP5004 SP5005 SP6772 6
7 CPU Board (Rabbit) XLR-8 Standard Version XLR-8 HS Version SP SP Main Board (for XLR-8 Base) SP6978 Main Board (Conformal Coated) SP6111 X-Axis Sensor SP6107 Sensor wiring harness, XLR-8 SP6989 Electrical Backpanel Assembly-Main Board not included SP6990 7
8 Full Drive Motion Assembly (including motor, leadscrew, sensors) SP6986 Chain with bracket SP6982 Standard Height Autosampler Mounting Block SP mm Extended Height Autosampler Mounting Block (for sample tubes that are 150mm in height) SP6985 Guide Rail Set, XLR-8 SP6987 8
9 Transport Cart Assembly, XLR-8 SP6983 RS232 Cable, Female/Female, 15 ft, Black SP6981 *Connects the autosampler to the computer RS232 Cable, Female/Female, 3 ft, Black SP6980 *Connects the head to the base Accessory Cart Polypropylene 24-in x 36-in SP7107 (for holding the XLR-8) Z-Axis Stepper Motor SP6108 9
10 X-Axis Stepper Motor SP6109 Y-Axis Stepper Motor SP6110 Y-Axis Sensor SP6106 Z-Axis Sensor SP6105 Arm Tube Assembly SP6202 CETAC White Y-Axis Lead Screw Kit SP
11 X-Axis Lead Screw Kit SP5940 Guide Shaft SP5221 Bearing, 7/8" x 3/8" SP6239 Bearing ½" ID (Set of 2) SP7999 Front Cover with Rinse Station SP6201 CETAC White color 10 Position standards rack, XLR-8 SP
12 Ordering To order, contact: Phone (Toll-Fee, USA): Phone (Outside USA): Fax: Teledyne CETAC Technologies Industrial Road Omaha, Nebraska 68144, USA For questions about service and repair, call us at the numbers above or Trademark Acknowledgements: PharMed and Tygon are registered trademarks of Saint-Gobain Performance Plastics. Viton is a registered trademarks of E.I. du Pont de Nemours and Company. Superthane is a registered trademark of NewAge Industries, Inc. 12
XLR-8 60 Extended Rack Autosampler
XLR-8 60 Extended Rack Autosampler ACCESSORIES AND PARTS CATALOG Catalog part number 620131 Rev 4, June 2018 Accessories and Supplies Sample Probes Length: 10 inches (25.4 cm) Probe Material: FEP-covered
More informationACCESSORIES AND PARTS CATALOG
ASX-560 AUTOSAMPLER ACCESSORIES AND PARTS CATALOG Catalog part number 620127 Rev 9, February 2018 Accessories and Supplies Sample Probes Length: 10 inches (25.4 cm) Probe Material: FEP-covered carbon fiber
More informationACCESSORIES AND PARTS CATALOG
ASX-280 AUTOSAMPLER ACCESSORIES AND PARTS CATALOG Catalog part number 620130 Rev 7, February 2018 Accessories and Supplies Sample Probes Length: 10 inches (25.4 cm) Probe Material: FEP-covered carbon fiber
More informationASX-1400 and ASX-1600 RANDOM ACCESS AUTOSAMPLER ACCESSORIES AND PARTS CATALOG
ASX-1400 and ASX-1600 RANDOM ACCESS AUTOSAMPLER ACCESSORIES AND PARTS CATALOG Catalog part number 620081 Rev 2, November 2017 Accessories and Supplies Z-Axis Drive Assembly SP6212 Spring Kit Drip Cup Assembly
More informationAutomated Liquid Handling Station
Automated Liquid Handling Station Quick Installation Guide Manual Part Number 32-0406-048 Rev 0 COPYRIGHT 2018 Teledyne Technologies Incorporated. All rights reserved. 32-0406-048 Rev 0, May, 2018 Printed
More informationXLR-8 60 Extended Rack Autosampler
XLR-8 60 Extended Rack Autosampler Quick Installation Guide Manual Part Number 480226 Rev 0 COPYRIGHT 2015 Teledyne Technologies Incorporated. All rights reserved. 480226 Rev 0, October, 2015 Printed in
More informationEPOND SA CP 389 CH Vevey Switzerland.
EPOND SA CP 389 CH - 1800 Vevey Switzerland http://www.e-pond.biz SC-2 & SC-4 Accessories Commonly used Nebulizers with SC-2/SC-4 and FAST PFA-ST Nebulizer, High Pressure (Detachable ES-2040-57 Capillary)
More informationENC-560 Autosampler Enclosure
ENC-560 Autosampler Enclosure Installation Guide Manual Part Number 480232 Rev 1 COPYRIGHT 2016, 2017 Teledyne Technologies Incorporated. All rights reserved. 480232 Rev 1, June, 2017 Printed in USA. Teledyne
More informationCETAC Z-Drive Nylon Cable
CETAC Z-Drive Nylon Cable Installation Guide Manual Part Number 610104 rev2, 2010-14 Teledyne Technologies Inc, Printed in USA Overview This guide describes how to replace the nylon line which operates
More informationAccess your fiber assemblies in the front of the enclosure to your fiber splices via a rear door without disturbing the fiber.
Z Hinged Fiber Adapter Panel Enclosure Access your fiber assemblies in the front of the enclosure to your fiber splices via a rear door without disturbing the fiber. Customer Support Information Order
More informationNEMA-Rated Fiber Optic Wallmount Enclosure. Protects your fiber cabling in a damp environment.
JPM4001A-R2 NEMA-Rated Fiber Optic Wallmount Enclosure Protects your fiber cabling in a damp environment. BLACK BOX Single rubber gasket door has a hex nut security lock. Cable enters or exits the enclosure
More informationGX-271 ASPEC Gilson, Inc. All Rights Reserved. LT
GX-271 ASPEC GX-271 ASPEC World Headquarters Gilson, Inc. 3000 Parmenter Street P.O. Box 620027 Middleton, WI 53562-0027 USA Telephone: 608-836-1551 Fax: 608-831-4451 Gilson S.A.S. 19, avenue des Entrepreneurs
More informationConductivity Sensors. Model 140, 141, 142. Product Data Sheet series/rev.a June 1998
Product Data Sheet 71-140 series/rev.a June 1998 Model 140, 141, 142 Conductivity Sensors HIGH TEMPERATURE 316 SS AND PEEK CON- STRUCTION operates up to 200 C (392 F). MODEL 140 RETRACTABLE SENSOR installs
More informationChemWell Replacement Parts & Accessories
ChemWell Replacement Parts & Accessories Description ChemWell Duffle Bag ChemWell Mouse Pad Photometer Calibration Kit Reagent Cooling Accessory Ordered with New ChemWell - RCA (230V) Reagent Cooling Accessory
More informationFitting Systems. Leak-free, ee, simple-to-use 1/4-28 and M6 fitting types in
Fitting Systems Inside... Gripper Fitting System... 2 Assembling...2 Ordering...3 Flanged Fitting System... 4 Ordering...4 Inverted Cone Fitting System... 5 Ordering...5 Omnigrip Fitting System...6 Ordering...6
More informationUsing Plates and Vials with ACQUITY UPLC and ACQUITY UPLC H-Class Systems
Using Plates and Vials with ACQUITY UPLC and ACQUITY UPLC H-Class Systems Follow the guidelines in this document when using plates and vials with ACQUITY UPLC and ACQUITY UPLC H-Class systems. For assistance
More informationInformation Sheet Polyethylene Tank Assemblies
Information Sheet Polyethylene Tank Assemblies No. 27421 10 Gallon Tank Assembly Ultraviolet resistant, yellow polyethylene tank. Molded recesses for mounting of any LMI Series A, J, or P pump. Convenient
More informationDistek Parts & Accessories. The New Evolution 6300
Distek Parts & Accessories The New Evolution 6300 Distek Parts Accessories List 2 Table of Contents Disintegration Page 3 Dissolution Testing Pages 4-11 Fiber Optics Page 12 Friability Page 12 Hardness
More informationConnectors & Connectors with valves
Connectors & Connectors with valves Inside... Omnifit Cap instructions... Small Bore Connectors... 3 with valves... Large Bore Connectors... 5 with valves... 5 T Block Connector... 6 In-line Connectors...
More informationLiquid Chromatography LC Consumables SSI-LC
Liquid Chromatography LC Consumables SSI-LC-10-2017 Table of Contents HPLC Pumps...3 LC-30AD... 3 LC-20AD / LC-20AB / LC-20ADXR... 4 LC-20AT... 4 LC-20Ai... 5 LC-10ADvp... 5 LC-10ATvp... 6 LC-10Ai... 6
More informationFOR MORE INFORMATION Speak to your Macsim Sales Representative or phone Toll Free on
NEW SMALL - Blister Range FOR MORE INFORMATION Speak to your Macsim Sales Representative or phone Toll Free on 1800 022 019 www.macsim.com.au WOODS WOODS WOODS SOLID BRASS COUNTERSUNK HEAD PHILLIPS DRIVE
More informationThermo Scientific HyClone Single-Use Mixer (S.U.M.) Docking Station System
Thermo Scientific HyClone Single-Use Mixer (S.U.M.) Docking Station System The Thermo Scientific HyClone Single-Use Mixer (S.U.M.) is a product family of systems providing powerful and efficient mixing
More informationModular OEM-pumps. SP pumps are our new developed plastic molded pump line for high volume applications
Pumps for OEM, Metering and Dispensing Single Channel and Multi Channel Peristaltic Pumps Ceramic Piston Pumps Accurate Dispensing System Tubes Fittings S-series Modular pumps Modular OEM-pumps SP pumps
More informationThermo Scientific HyClone Single-Use Mixer (S.U.M.) 500 L
Thermo Scientific HyClone Single-Use Mixer (S.U.M.) 500 L The Thermo Scientific HyClone Single-Use Mixer (S.U.M.) is part of a product family which provides efficient and powerful mixing based on a conventional
More informationWRANGLER 1708AB, 2008AB
WRANGLER 1708AB, 2008AB WIRING DIAGRAM ITEM PART NO. DESCRIPTION QTY. 1 1393251 WIRE ASSEMBLY - CIRCUIT BREAKER TO BRUSH SWITCH 1 2 1393261 WIRE ASSEMBLY - CIRCUIT BREAKER TO VACUUM SWITCH 1 3 1393271
More informationReproduction. Not for. Pro Max 9000EA. Illustrated Parts List
Illustrated Parts List Pro Max 9000EA Model Mfg. No. Description 030409-0 ProMax 9000EA CE 030410-0 ProMax 9000EA UK 030411-0 ProMax 9000EA AU 030412-0 ProMax 9000EA MEA Manual Part No. Revision E Rev.
More informationThermo Scientific HyClone Single-Use Mixer (S.U.M.) 500 L
Thermo Scientific HyClone Single-Use Mixer (S.U.M.) 500 L The Thermo Scientific HyClone Single-Use Mixer (S.U.M.) is part of a product family which provides efficient and powerful mixing for a wide range
More informationThermo Scientific HyClone Single-Use Mixer (S.U.M.) 200 L
Thermo Scientific HyClone Single-Use Mixer (S.U.M.) 200 L The Thermo Scientific HyClone Single-Use Mixer (S.U.M.) is part of a product family which provides efficient and powerful mixing for a wide range
More informationU-5000AT Ultrasonic Nebulizer Operator s Manual
U-5000AT Ultrasonic Nebulizer Operator s Manual COPYRIGHT Copyright SD Acquisition, Inc., DBA CETAC Technologies 480001 REPRODUCTION All rights reserved. Reproduction or transmission of this document in
More information819 Injection Module User s Guide
819 Injection Module User s Guide LT2533/ 2004 Gilson, Inc. All rights reserved August 2004 Table of Contents Declaration of Conformity 1 Introduction 2 Installation 3 Operation 4 Maintenance Unpacking...
More informationFluoro plastic products
Volumetric flasks, PFA, class A 472 High transparency, individually calibrated ring-mark. Tolerances class A according to DIN EN ISO 1042. With lasered lot.number. Supplied with PFA screw-caps. Screw-caps
More informationVelocity Scientific Solutions
Shell Vials for Waters WISP, 8x40mm, 8mm Plug Vials Designed to work in the Waters WISP 96 position autosampler. Available in clear or amber Type I borosilicate glass, or polypropylene for easy disposal.
More informationThermo Scientific Manostat. Simon. & Vera. Variable Flow Pumps. Ideal for a wide variety of life science and medical applications: Features
Simon & Vera Variable Flow Pumps Pumps & Dispensers Ideal for a wide variety of life science and medical applications: Sample prep General dispensing Media dispensing Dilution blanks Dispensing diagnostics
More informationBalance Pricelist UK, 2011
www.mtonline.eu Balance Pricelist UK, 2011 Analytical Balances New Classic MS Analytical MS105 120g 0.01mg Ø80mm 11142056 4140 MS105/M 120g 0.01mg Ø80mm 11142058 4560 MS105DU 42g / 120g 0.01mg / 0.1mg
More informationPump Your Needs. WELCO s easy ordering system can match the best product to the customer s needs
Pump Your Needs. WELCO s easy ordering system can match the best product to the customer s needs WELCO Peristaltic pumps use a custom ordering system that enables part types and sizes to be selected according
More informationAgilent 1290 Infinity Autosampler
Agilent 1290 Infinity Autosampler Installation of the Large Volume Injection Kit General Information This note describes how to install the large volume injection kit into an Agilent 1290 Infinity Autosampler.
More informationCHROMATOGRAPHY. SYKAM S 6000 Valve Series
CHROMATOGRAPHY SYKAM S 6000 Valve Series Version: March 2011 SYKAM S 6000 Valve Series Rotor Seals Sykam offers a variety of different Rotor Seals materials to satisfy any possible application. All materials
More informationMitos P-Pump Accessories
Mitos P-Pump Accessories product datasheet page Flow Resistors 3 Flow Resistor Selection 6 Flow Resistor Kit 7 Mitos P Pump Vessel Holder Kit 9 Standard Vessel Compatibility Chart 11 Mitos P Pump Starter
More informationThermo Scientific HyClone Single-Use Mixer (S.U.M.) 50 L
Thermo Scientific HyClone Single-Use Mixer (S.U.M.) 50 L The Thermo Scientific HyClone Single-Use Mixer (S.U.M.) is part of a product family which provides efficient and powerful mixing for a wide range
More informationParts Catalog SLICING MACHINES
Parts Catalog 00N Slicer SLICING MACHINES MODELS: 00N, 0N & 9N -- IMPORTANT! TO EXPEDITE SHIPMENT OF PARTS, ALWAYS SPECIFY MODEL, REV, PART NUMBER, AND SERIAL NUMBER OF SLICER. GLOBE FOOD EQUIPMENT COMPANY
More informationCOYOTE LCC (Low Count Closure)
PLP Feature Focus 2009 Preformed Line Products OCTOBER 2012 Film available at www.preformed.com COYOTE LCC (Low Count Closure) Be sure to read and completely understand this procedure before applying product.
More informationMODEL 55C ECONOMY LIQUID FILTER FLOW RATES UP TO 200 GPM
MODEL 55C ECONOMY LIQUID FILTER FLOW RATES UP TO 200 GPM A NEW ERA IN FILTRATION PERFORMANCE AND INNOVATION TM ISO 9001 Chemelean Liquid Housings & Cartridges Looking for an easy to use, versatile filter
More informationSpark Holland introduces ALIAS for ÄKTA pure All-round, state-of-the-art
BETTER SAMPLE CARE Spark Holland introduces ALIAS for ÄKTA pure All-round, state-of-the-art autosampler for ÄKTA pure Spark Holland introduces ALIAS for ÄKTA pure All-round, state-of-the-art autosampler
More informationCOYOTE 9.5" x 19" (292 mm x 509 mm) Cross-Connect Dome Closure
AUGUST 2013 COYOTE 9.5" x 19" (292 mm x 509 mm) Cross-Connect Dome Closure Be sure to read and completely understand this procedure before applying product. Be sure to select the proper PREFORMED TM product
More informationCATALOG OF REPLACEMENT PARTS
CATALOG OF REPLACEMENT PARTS COMBI GAS OVENS MODELS ML-126836 ML-126837 ML-126838 VCG10H VCG10F VCG20H For additional information on Vulcan-Hart Company or to locate an authorized parts and service provider
More informationNEW Reactor-Ready Duo Lab Reactor
1 NEW Reactor-Ready Duo Lab Reactor 1 2 Duo Core System RR121300 Reactor-Ready Duo Core System. Includes: 1 6,725.00 Duo stand with base, drip tray, support rods, bosses and all clamps 4 x Hose tidies
More informationSeries C9 Electronic Metering Pump. Specification Sheet and Assembly Details Manual No : 1619, 1795 Rev. : G, E Rev. Date : 6/09, 10/2015
INJECTION CHECK VALVE COUPLING NUT DISCHARGE TUBING 4 FUNCTION VALVE PUMP HEAD SPACER, E.P.U. METERING PUMP HOUSING RETURN LINE (PRESSURE RELIEF) SPEED KNOB STROKE KNOB SUCTION FITTING SUCTION TUBING WEIGHT
More informationAgilent 1200 Series Standard and Preparative Autosamplers
Agilent 1200 Series Standard and Preparative Autosamplers User Manual Agilent 1200 Series Autosampler User Manual Agilent Technologies Notices Agilent Technologies, Inc. 2006,2008 No part of this manual
More information215E. Operator and Parts Manual MM158
5E Operator and Parts Manual MM58 This manual is furnished with each new TENNANT Model 5E This manual consists of Specifications; Operation; Maintenance; Appendix; the How To Use This Manual; Low Dump
More informationOEL Spare Parts Drawing ML5720/ML5721. www MK-Electronic de. Revision 2
OEL Spare Parts Drawing ML520/ML521 Revision 2 Printer General Assy 5 4 11 21 0 16 10 19 2 25 24 26 2 28 29 19 19 0 4 14 15 22 A 9 0 5 19 A 1 20 20 20 21 12 1 2 8 2 6 6 2 Lower Cover Assy 19 1 24 1 16
More informationGeneral Specifications
General Specifications GS 22B01C52-01EN-A M-650, M-750 and M-651 3-Valve Manifolds for Differential Pressure INTRODUCTION The PGI 3-Valve manifolds are designed for mounting on differential pressure transmitters
More informationSybaritic, Inc James Avenue South Minneapolis, Minnesota USA 1 + (952)
PARTS CATALOG Sybaritic, Inc. 9220 James Avenue South Minneapolis, Minnesota 55431 USA www.sybaritic.com 1 + (952) 888.8282 E4000-01 CONTROL PANEL E4000-02 LCD DISPLAY E4000-02A LCD DISPLAY-2G E4000-03
More informationLPC Series Fiber Panel 12/24 Fiber Rack-Mount Enclosure Installation Instructions
LPC Series Fiber Panel 12/24 Fiber Rack-Mount Enclosure Installation Instructions ADCP-92-129 Issue 1 6/2010 Content Page INTRODUCTION.............................................................................
More informationConductivity Sensors. Model 140, 141, 142. Product Data Sheet series/rev.b February 2011
Product Data Sheet 71-140 series/rev.b February 2011 Model 140, 141, 142 Conductivity Sensors RUGGED CONSTRUCTION withstands high temperature and pressure TWO MOUNTING CONFIGURATIONS: screw-in and retractable
More informationTECHNICAL BROCHURE BSPMSPH R1 SOLD SEPARATELY OR BUILT IN. PrimeLine SP SPM & SPH SERIES
TECHNICAL BROCHURE BSPMSPH R1 SOLD SEPARATELY OR BUILT IN PrimeLine SP SPM & SPH SERIES FEATURES Self Priming Design: Features a replaceable check valve which acts to retain sufficient liquid in the casing
More informationThermocouples W A T L O W
W A T L O W Over 90 years of manufacturing, research and design makes Watlow a world class supplier of temperature measurement products. We have designed and manufactured millions of thermocouples for
More informationSPECIFICATIONS. Vortex-Genie Model Vortex-Genie 1 Vortex-Genie 2 Supplied Pop-off Cup 3-inch Platform, Pop-off Cup (2700 for 50Hz models)
Vortex-Genie Mixers Vortex-Genie 1 Vortex-Genie 2 Violent single high-speed vortexing Easy-to-use Touch On operation Large, 6mm orbit for aggressive vortexing of difficult samples May be used with Pop-off
More informationAgilent 1260 Infinity Standard Autosampler
Agilent 1260 Infinity Standard Autosampler User Manual Agilent Technologies Notices Agilent Technologies, Inc. 2007-2012, 2013 No part of this manual may be reproduced in any form or by any means (including
More information235/235P Autoinjector User's Guide
235/235P Autoinjector User's Guide LT2401/ 2003 Gilson, Inc. All rights reserved. January 2003 Table of Contents Declaration of Conformity 1 Introduction 2 Installation Safety Precautions... 1-2 Unpacking...
More informationGeneral Specifications
General Specifications GS 22B01C53-01EN-A M-675, M-775 and M-678 5-Valve Manifolds for Natural Gas Differential Pressure INTRODUCTION The PGI 5-Valve manifolds are designed for natural gas service and
More informationSupporting the needs for investigating High Energy Pulsed Light applications
Model X-1100 Pulsed Light for Research and Development Supporting the needs for investigating High Energy Pulsed Light applications PERFORMANCE WITH A LOW COST The X-1100 is an advanced, laboratory R&D
More informationBennett Sample Pumps. Submersible Piston Pump U.S. Patent No Canadian Patent nos & Portable and dedicated units
Bennett Sample Pumps Submersible Piston Pump U.S. Patent No. 4295801 Canadian Patent nos. 1166075 & 1187331 Portable and dedicated units Pumping lifts-0 to 1000 feet Infinitely variable flow rates 1.4
More informationSeries C1 Electronic Metering Pump. Specification Sheet and Assembly Details Manual No : 1619, 1829 Rev. : G, D Rev. Date : 6/09, 10/2015
INJECTION CHECK VALVE COUPLING NUT DISCHARGE TUBING 4 FUNCTION VALVE PUMP HEAD SPACER, E.P.U. METERING PUMP HOUSING RETURN LINE (PRESSURE RELIEF) SPEED KNOB STROKE KNOB SUCTION FITTING SUCTION TUBING WEIGHT
More informationPARTS LIST WRANGLER 2625 DB
PARTS LIST WRANGLER 2625 DB 1 NOTES 2 BRUSH GEAR MOTOR ITEM PART NO. PART DESCRIPTION QTY. 2393001 COMPLETE MOTOR ASSEMBLY 1 101 3391221 NEGATIVE LEAD 1 102 3391201 1/4-20 X 7 3/4THRU BOLT 2 103 10-24
More informationThermo Scientific HyClone Single-Use Mixer (S.U.M.) 2000 L
Thermo Scientific HyClone Single-Use Mixer (S.U.M.) 2000 L The Thermo Scientific HyClone Single-Use Mixer (S.U.M.) is part of a product family which provides efficient and powerful mixing for a wide range
More information98 동방하이테크상사 T.(02) F.(02)
98 동방하이테크상사 http://www.allpump.co.kr T.(0)57-69 F.(0)57-69 00--7 troduction to Upchurch Scientific Valves Valves troduction Valves jection and Selection Valves for Pressures to,000 psi (69 bar) Switching
More informationCGR-30P PREMIUM Worksheet
Rev: D CGR-30P PREMIUM Worksheet Replace your Tachometer with the CGR-30P Download this file, fill it out and then save it. Include it with your order. www.buy-ei.com General Info: Aircraft Information:
More informationFilter Holder Manifold User Guide. 3- and 6-Place Stainless Steel Manifolds 3- and 6-Place Sterility Test Manifolds 3-Place PVC Manifold
Filter Holder Manifold User Guide 3- and 6-Place Stainless Steel Manifolds 3- and 6-Place Sterility Test Manifolds 3-Place PVC Manifold Notice The information in this document is subject to change without
More informationProMinent. ProMinent D4a Metering Pumps with built-in proportional controllers
D4a Metering Pumps with built-in proportional controllers A series of solenoid-driven metering pumps with built-in ph controller, oxidation-reduction potential (Redox) controller or chlorine controller.
More informationNew Products Programs & Packaging
#3 Catalog New Products Programs & Packaging from NEW Performance Products Custom instruments engineered to give you the reliability and accuracy you need on the street, off road or track. The choice of
More information1 RS-300/D 320/D 340/D 350H Parts Manual
300/D 320/D 340/D 350H Parts Manual Table Of Contents Three Point Hitch / Hitch Frame Assembly... 3 Tongue Pull Hitch Assembly... 7 Main Gearbox... 11 Crank Handle & Gear... 13 Hydraulic Lift... 15 Rotor
More informationControl Drift with Redball Broadcast Hoods 3/30/2018. Redball-Hooded Sprayers Reduce Drift 2018 Season
20'' 3/30/2018 Redball-Hooded Sprayers Reduce Drift 2018 Season Control Drift with Redball Broadcast Hoods The Redball Broadcast Spray Hood was first released in 1993. In 2013 Willmar Fabrication re-launched
More informationMM184 Rev. 12 (9 94)
465 480 490 MM184 Rev. 12 (9 94) This manual is furnished with each new TENNANT Model 465, 480, and 490. It provides necessary operating and preventive maintenance instructions. Read this manual completely
More informationeconomics and performance Spark Holland introduces OPTIMAS The optimum balance of BETTER SAMPLE CARE
BETTER SAMPLE CARE Spark Holland introduces OPTIMAS The optimum balance of economics and performance Spark Holland introduces OPTIMAS The optimum balance of economics and performance OPTIMAS The optimum
More information18SP621* Series 50 Gillig Phantom Diesel Particulate Filter Installation
18SP621* Series 50 Gillig Phantom Diesel Particulate Filter Installation *Revision 6/12/06 DESCRIPTION A replacement diesel particulate filter assembly has been released for use in Gillig Phantom buses
More informationTELEDYNE HASTINGS INSTRUMENTS
TELEDYNE HASTINGS INSTRUMENTS MODELS HFM-D-3 & 305 HFC-D-3 & 307 FEATURES Flows from 0-25 slm (N2 Equivalent) up to 0-2500 slm (N2 Equivalent) Accuracy in Nitrogen (0.2% of Full scale + 0.5% of Reading)
More informationDynaLoop 25 and DynaLoop 90. Instruction Manual
0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 0 5 10 15 20 25 DynaLoop 25 and DynaLoop 90 Instruction Manual Catalog Numbers 750-0451 (25 ml) 750-0452 (90 ml) For technical support, call your
More informationCOYOTE 9.5" x 19" (292 mm x 509 mm) Dome Closure
AUGUST 2012 COYOTE 9.5" x 19" (292 mm x 509 mm) Dome Closure Be sure to read and completely understand this procedure before applying product. Be sure to select the proper PREFORMED product before application.
More information221 and 222 XL Liquid Handlers User s Guide
221 and 222 XL Liquid Handlers User s Guide Errata 221/222 XL User s Guide page Appendix A-2 Model 221XL Model 222XL Part Number Qty Part Number Qty Description... 27067213 1 27067213 1 Constricting needle,
More informationDupont Vespel CR-6100
oulden Installation Guide for Dupont Vespel CR-6100 DuPont Vespel CR-6100 is a composite material of Teflon PF and long carbon fibers. It is used for stationary wear components or inserts in centrifugal
More informationR.A.M. Large Opening Vials, 12x32mm, 9mm Neck Finish
Vials 40% larger opening, the R.A.M. Vial is specifically designed to work in robotic arm autosamplers such as Agilent. Choose from clear or amber Type I borosilicate glass. Available with graduated marking
More informationNEW HPLC - SYSTEM LINE
NEW HPLC - SYSTEM LINE S c h a m b e c k S F D G m b H Drieschweg 13A D-53604 Bad Honnef/Germany Phone: +49 2224 9239-0 E-Mail: info@schambeck-sfd.com Internet: www.schambeck-sfd.com S 9425 HPLC solvent
More informationMTI SPARE PARTS LIST FOR 86XX
MTI SPARE PARTS LIST FOR 86XX 1/12 INDEXER MODULE 03215 LEAD SCREW 03225 PULLEY DRIVE CONVEYOR 03231 NUT, LEAD 100-032 CAPACITIVE SENSOR 109-001 CASSETTE SWITCH 112-012 GEAR MOTOR, LEADSCREW 112-019 GEAR
More information833 IC Liquid Handling Unit
833 IC Liquid Handling Unit CH-9101 Herisau/Switzerland E-Mail info@metrohm.com Internet www.metrohm.com Instructions for Use 8.833.1003 CH-9101 Herisau/Switzerland E-Mail info@metrohm.com Internet www.metrohm.com
More informationPUMP SYSTEM OPERATING MANUAL:
OPERATING MANUAL: PUMP SYSTEM The MASTERFLEX C/L Pump Systems are small peristaltic pumps with integral drive motors and are intended for use with a series of tubing sizes that provide flow rates in the
More informationMODEL 11 CAMERA DOLLY OUR MOST COMPACT HYDRAULIC LIFT DOLLY
MODEL 11 CAMERA DOLLY OUR MOST COMPACT HYDRAULIC LIFT DOLLY Motion Picture & Television Equipment The Model 11 is our smallest Dolly. Lightweight and compact, it is built with the same high quality standards
More informationPORTAFOLIO DE CROMATOGRAFÍA LABINS
PORTAFOLIO DE CROMATOGRAFÍA LABINS LABINS SAS NIT 900090654 6 Tel 57 1 4725717 Cel 57 3156342765 labins sas@outlook.com gerencia@labins.com.co www.labins.com.co Catálogos: Agilent Technologies, SGE, Separation
More informationAUDIO & VIDEO SOLUTIONS
AUDIO & VIDEO SOLUTIONS Welcome to sonorahifi.com Home of Sonora furniture and brackets. Sonora is proudly designed and distributed by Daveco Ltd., as are Omage speakers, Maestro cables and power bars,
More informationConductivity. Inductive Conductivity Sensors. Features and Benefits DATA SHEET. Wide Measuring Range. Low-maintenance Design. Complete Digital System
DATA SHEET Inductive Conductivity Sensors Features and Benefits Wide Measuring Range Hach s Inductive Conductivity Sensors measure 200 up to 2,000,000 microsiemens/cm. A built-in Pt 1000 RTD compensates
More informationCOMMERCIAL AUTOMATIC WASHER
COMMERCIAL AUTOMATIC WASHER MODEL NO. MAT14PRAWW0 5 09 Litho In U.S.A. (BT) (psw) c 2009 WHIRLPOOL CORPORATION Part No. Rev. B TOP AND CABINET PARTS 2 TOP AND CABINET PARTS 1 Literature Parts W10135294
More informationCM Lodestar Electric Chain Hoist Electrical Parts List
CM Lodestar Electric Chain Hoist Electrical Parts List MODELS Key No. Part Name No. Req'd A, A-2, AA, AA-2, B, B-2 C, C-2, E, E-2, F, F- 2, H & H-2 J, J-2, JJ, JJ-2, L, L-2, LL, LL-2, R, R- 2, RR, RR-2,
More informationCommitment To Quality
Commitment To Quality Franklin Electric is committed to provide customers with defect free products through our program of continuous improvement. Quality shall, in every case, take precedence over quantity.
More informationFlow Module. Instruction Manual. Flow Module
7200-101 Flow Module Instruction Manual 7200-101 Flow Module 7200-101 Flow Module Instruction Manual Publication No. 984-11013 LI-COR Biosciences 4647 Superior Street P.O. Box 4425 Lincoln, Nebraska 68504
More informationNT Flowmeter, Model 4401
ADVANCED MATERIALS HANDLING NT Flowmeter, Model 4401 Simultaneous flow and pressure outputs for high-temperature applications Now more than ever there is a need to measure high-temperature chemicals to
More informationBe sure to read and completely understand this procedure before applying product. Be sure to select the proper PREFORMED product before application.
5 NOVEMBER 2010 COYOTE Dome 9.5 x 28 Be sure to read and completely understand this procedure before applying product. Be sure to select the proper PREFORMED product before application. 1. 7. 2. 4. 10.
More informationVACUUM CONTROL SPI-MODULE INSTRUCTION MANUAL
SUPPLIES R VACUUM CONTROL TM SPI-MODULE INSTRUCTION MANUAL SPI Supplies Division of STRUCTURE PROBE, inc. 69 East Gay Street, P.O. 66, West Chester, PA 1981-066 (610) 46 400 Fax: (610) 46-7 E-Mail SPISPI@SPI.com
More informationPhysiological Calibration Standard II Calibration standard physiological fluid CALIBRATION STANDARD PROTEIN
80-6000-32 Physiological Calibration Standard II 80-2037-62 Calibration standard physiological fluid 80-2037-61 CALIBRATION STANDARD PROTEIN HYDROLYSATE 80-2104-53 1/8" FLANGELESS FITTING (PK 5) 80-2108-41
More informationExpansion Signal (XSIG) Card Installation Instructions
Expansion Signal (XSIG) Card Installation Instructions Introduction This publication describes the installation procedure for the Expansion Signal (XSIG) Card (4100-5116). This product is compatible with
More informationPARTS CATALOG ODYSSEY INCLUDES MOWER
PARTS CATALOG 8-3350 ODYSSEY INCLUDES MOWER INDEX PAINT ENGINES GENERAL INFO PRODUCT IDENTIFICATION NUMBERS (P.I.N.) OR SERIAL NUMBERS (S/N) ENGINE MODEL, SERIAL AND SPECIFICATION NUMBERS TRACTOR MODEL
More informationAgilent 1200 Series High Performance Autosamplers & Micro Well Plate Autosampler
Agilent 1200 Series High Performance Autosamplers & Micro Well Plate Autosampler User Manual 1200 Series Autosamplers User Manual Agilent Technologies Notices Agilent Technologies, Inc. 2006, 2008 No part
More information