Flow Module. Instruction Manual. Flow Module

Size: px
Start display at page:

Download "Flow Module. Instruction Manual. Flow Module"

Transcription

1 Flow Module Instruction Manual Flow Module

2 Flow Module Instruction Manual Publication No LI-COR Biosciences 4647 Superior Street P.O. Box 4425 Lincoln, Nebraska USA Telephone: (402) FAX: Toll-free (U.S. & Canada)

3 NOTICE The information contained in this document is subject to change without notice. LI-COR MAKES NO WARRANTY OF ANY KIND WITH REGARD TO THIS MATERIAL, INCLUDING, BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. LI-COR shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance, or use of this material. This document contains proprietary information which is protected by copyright. All rights are reserved. No part of this document may be photocopied, reproduced, or translated to another language without prior written consent of LI-COR, Inc. Copyright 2010, LI-COR, Inc. Publication No Printing History New editions of this manual will incorporate all material since the previous editions. Update packages may be used between editions which contain replacement and additional pages to be merged into the manual by the user. The manual printing date indicates its current edition. The printing date changes when a new edition is printed. (Minor corrections and updates which are incorporated at reprint do not cause the date to change). Microsoft and Windows are registered trademarks of Microsoft Corporation. Eurofast is a registered trademark of Turck Inc. LI-COR, Inc Superior Street Lincoln, Nebraska Phone: FAX: Toll-free: (U.S. & Canada) envsales@licor.com 1st Printing - March, nd Printing October, 2013 ii

4 Table of Contents Overview of the What s What... 4 Initial Setup... 5 Powering the Cabling... 5 Attaching the Tubing and Air Filter... 6 Mounting the Flow Module... 8 Using the Controlling Flow Using Manual Controls Controlling Flow Via the Windows Application Software Monitoring Flow Rate Flow Rate Data Output Maintenance Changing the Fuse Cleaning the Air Filter Screen Specifications Warranty iii

5 Overview of the Flow Module What s What The is a high performance flow module designed for use with the LI-7200 enclosed CO 2 /H 2 O Analyzer, or other closed path analyzers. The attaches to the LI-7550 Analyzer Interface Unit of the LI-7200 to provide an integrated flow solution; flow can be controlled through software, or manually via the control panel. The provides a constant flow of SLPM, in increments of 0.1 SLPM, and requires only about 13W power during normal operation. If you have just taken delivery of your , check the packing list to verify that you have received everything that was ordered and that you have also received the following items: Mounting Kit (part # ). This kit contains all of the hardware needed to mount the Flow Module to a tripod or other mounting post. Spare Parts Kit - (part # ). This kit contains replacement parts for your Among other items, the spares kit contains tubing and the power and accessory cables. As you become familiar with the Flow Module you will learn which items to keep close at hand and which items can be stored away. The spares kit includes these commonly used items: Description Qty. LI-COR Part No. Tygon Tubing, O.D Hose Barb, 3/8 NPT Hose Barb, 1/4 NPT Hose Clamp, O.D Air Filter Air Filter Replacement Screen Accessory Cable, 5m, 5PF-5PM Exhaust Fitting Power Cable, 5m

6 Initial Setup Powering the The 5 meter power supply cable included (p/n ) has a circular connector that attaches to the Flow Module front panel at the location marked POWER. The other end has bare wire leads for connection to a VDC supply (50W or more capability, 2A or greater). Connect the red lead to the positive terminal of the power supply, and the black wire to the negative terminal. Cabling The 5 meter Accessory cable included (p/n ) has male and female circular connectors that attach to the and LI-7550 front panels, respectively, at the connectors marked ACCESSORY. LI Flow Module Accessory Connector Accessory Connector Accessory Cable p/n Figure 1. Attach the Accessory Cable to the Accessory connectors on the LI-7550 and front panels. 5

7 Attaching the Tubing and Air Filter IMPORTANT NOTE: Clamping the tubing to the hose barbs and air filter as described below is very important. The tubing will initially seal without hose clamps, but in our experience, leaks will develop slowly over time. Note, too, that the Tygon tubing should not be draped over support stands or other equipment, as it can soften in sunlight and warm weather, causing it to kink, resulting in flow restriction. There is a 16 length of I.D. Tygon tubing in the spares kit that is used for air flow between the LI-7200 sensor head and the Flow Module. We recommend that you always attach the air filter in-line between the LI-7200 sensor head and the AIR IN port. Follow these steps to attach the Tygon tubing and air filter: 1. Remove the red shipping plugs from the EXHAUST and AIR IN ports. Screw the white exhaust fitting into the EXHAUST port on the front panel. Tighten with an open end wrench; this fitting serves to hold a small filter screen in place inside the port. 3/8 hose barb Exhaust fitting Figure 2. Thread the exhaust fitting into the EXHAUST port and hand tighten. Thread the 3/8 hose barb into the AIR IN port. 2. Locate the 3/8 nickel plated hose barb in the spares kit (p/n ). Thread the hose barb into the AIR IN port. Tighten with an open end wrench. 6

8 3. Cut a 4 section from the length of Tygon tubing. Place a hose clamp over this section of tubing, and push onto the hose barb. Tighten the hose clamp. TIP: Use a pair of pliers to tighten the hose clamp initially; after you have tightened the clamp once, you ll be able to tighten the thumb screw by hand. 4. Place another hose clamp over the short section of tubing, and push the tubing onto the air filter. Note the orientation of the filter; the arrow on the body of the filter must face toward the instrument. Make sure the arrow points toward the instrument. Figure 3. Note the orientation of the arrow on the body of the air filter, and clamp onto the short length of tubing. 5. You can now clamp the long length (however long you determine is needed to run to the LI-7200 sensor head) of tubing onto the other end of the air filter, and run the tubing to the AIR OUT port on the LI-7200 sensor head (the draws air through the sensor head). Note that the LI-7200 sensor head ships with two Swagelok fittings installed in the air inlet and outlet ports. You will need to remove the Swagelok fitting on the AIR OUT port and install the ¼ hose barb (p/n , in the spares kit) to attach the Tygon tubing. Clamp the tubing at the hose barb on the LI-7200 sensor head with a hose clamp from the spares kit. The finished cabling configuration (including optional Auxiliary Sensor Interface and sonic anemometer) might appear something like that shown in the illustration below. 7

9 Air OUT use hose barb and clamp here LI Auxiliary Sensor Interface LI-7550 Analyzer Control Unit Flow Module Power Supply VOLTAGE CURRENT VIN- VIN+ Air IN ACCESSORY 1/2 ID Tygon Tubing Filter Power Cable Mounting the Flow Module Two mounting plates (p/n ) are included that can be used to mount the using hose clamps to secure the box to a tripod or other post. There are holes in the four corners of the box, as well, that can be used to attach the box directly to a flat surface, if desired. The mounting plates and hose clamps are designed to accomodate a square or circular mounting post of up to 2.75" in width (diameter). Hardware is included to attach the mounting plates to the using 4 hex head bolts (p/n ). The hose clamp mounting brackets are attached to the mounting plates, and then the hose clamps can be inserted through the holes in the hose clamp mounting brackets, and tightened around the post, as shown in Figure 4. The hose clamp mounting brackets can be inserted through any of the holes in the mounting plates to accomodate a variety of mounting options, as shown in Figure 4. 8

10 Flow Module Flow Module Flow Module 4 5 Item Qty Part No Description M6x1 x 16 MM Hex Head Bolt Flat Washer 1/4 x 5/8 Split Washer 5/16 Single Bolt Flared Leg Mounting Bracket Hose Clamp, 9/16 26 cm Mounting Plate 5/16-24 x 1/2 Hex Head Bolt (included w/item #4) 5/16 Flat Washer (included w/item #4) Figure 4. Attach mounting plates to the , attach hose clamp mounting brackets to mounting plates, and secure to mounting post using hose clamps. There are some additional considerations that should be taken into account when locating the Flow Module, including: 1. The Accessory cable that connects to the LI-7550 Analyzer Interface Unit is 5 meters in length; determine the height at which the LI-7550 and LI-7200 sensor head will be mounted, and plan to mount the Flow Module accordingly. 2. The thermal properties of the Flow Module are such that it is OK to place the box in direct sun. 3. The power cable provided is 5 meters in length. Longer cables can be purchased through distributors of Turck, Inc. Note, however, that longer cables will cause voltage drops. A minimum of 10.5V, 50W must be available to the Flow Module. A ground lug is provided on the Flow Module front panel for connection to Earth Ground, if desired. 9

11 Using the The air flow can be controlled and/or monitored manually, using the control panel inside the case, or via software with the LI-7200 Windows application software (when connected to an LI-7550 with the LI-7200 sensor head attached). Controlling Flow Using Manual Controls The control panel appears as shown below; it consists of a display, adjustment knob, LED indicators, and push buttons to select certain functions Flow Control Module 15.1 Measured Flow SLPM Set Flow SLPM/% Pressure Drop kpa Motor Drive % Address Power Save In Memory Toggle with Menu button Flow ON Menu Adjust Store In Memory Flow ON/OFF Power Figure control panel. There are six LEDs below the display that are toggled with the menu button; the display will change according to which LED is active. If, for example, the Measured Flow LED is lit, pressing the Menu button once will toggle the display to the Set Flow function, and the Set Flow LED will be illuminated. The flow rate can then be set using the Adjust knob. 10

12 The control panel functions are as described below: Measured Flow The display will show the current flow rate, in mass flow units of Standard Liters Per Minute (SLPM). Set Flow Allows you to set the desired flow rate, in SLPM, or in an uncontrolled constant blower drive mode, given as a percentage of the total flow capacity. Flow rates are adjustable between approximately SLPM, in 0.1 liter increments. Use the Adjust knob to change the desired flow rate. If you turn the Adjust knob past 18.0 SLPM, the display will change to show a C (Constant), and the displayed setting is constant blower motor drive in % air flow. During normal operation with the LI-7200, a flow setting of about 15.0 SLPM is adequate for most measurement protocols, including eddy covariance measurements. Pressure Drop (kpa) This is an indicator of the blower pressure, which indicates loss due to tubing, filters, and the LI-7200 sensor head (or any other obstructions). The range is from kpa, with a normal reading of about 1.0 kpa. If the air filter becomes clogged, this number will increase, which is a useful diagnostic indicator for cleaning the filter (see Figure 8, page 19). NOTE: On initial startup, you might want to record the Pressure Drop and Motor Drive (below) readings, to establish a baseline of normal unobstructed readings. Motor Drive (%) Displays the Pulse Width Modulation (PWM) drive input to the blower motor as a percentage. During normal operation, the blower motor will operate at about 25% drive. As with the Pressure Drop above, if the air filter becomes clogged, this number will increase (see Figure 9, page 20). This is a useful diagnostic indicator for cleaning the filter. As the filter becomes clogged (or the air hose is kinked), the flow rate controls will increase the PWM drive to the blower motor to maintain the desired flow rate. This, in turn, will require more power. Address Displays the accessory bus address, between This is primarily used for future expansion possibilities, where multiple instruments may be connected via the Accessory port. When using the LI-7200 Windows application software to control the Flow Module, this address must match the address chosen in the Settings Window, Flow Module tab (see page 13). Power Save After about 7 minutes of control panel inactivity, the control panel will enter a power save mode, in which almost all of the display LEDs will turn off, leaving only the Power Save LED illuminated. Press any 11

13 other button or turn the Adjust knob to take the control panel out of power save mode. Power Illuminates when power is applied to the instrument. This LED will always be on when power is applied. In Memory The In Memory LED indicates when the seven segment display matches the parameter stored in memory. The two parameters that can be stored are the Flow setting and the Address. Whenever the Set Flow LED is selected, the Flow setting is recalled from memory and entered on the display, and the In Memory LED will be lit. If the Adjust knob is turned, the In Memory LED will remain off until the Store In Memory button is pressed or the Adjust knob is turned until the displayed setting once again matches the stored seting. This same behavior applies the Address LED. Store In Memory The has some built in memory for retaining the desired Set Flow rate and Address. These values are retained in memory after the is powered off. When the desired flow rate is displayed during adjustment, press the Store In Memory button to save to memory. When the displayed Set Flow setting matches that which is stored in memory, the In Memory LED (above) will illuminate. When the display Address matches the address stored in memory, the In Memory LED will be lit. Flow ON/OFF Turns the blower motor drive on or off. Menu button Toggles the display between the five menu selections indicated by the LEDs beneath the display. 12

14 Controlling Flow Via the Windows Application Software The Flow Module can be operated through the LI-7200 Windows application software via the Flow Module tab in the Settings window (below). The Settings window, Flow Module tab displays current readings for measured flow, pressure drop, and motor drive. Measured flow is displayed in Standard Liters Per Minute (SLPM), or in Liters Per Minute (LPM), which is volumetric flow corrected for temperature and pressure. Use the Flow menu to toggle the blower motor drive On or Off. Use the Address menu to select the accessory bus address to use, between This is primarily used for future expansion possibilities, where multiple instruments may be connected via the Accessory port. This address must match the one set on the control panel (an address of 32 is typical). The actively controlled flow rate can be set in SLPM; move the slider bar to choose a flow rate between 10 and 18 SLPM. The blower motor drive can also be set as a percentage. When the Set the flow rate to a motor speed radio button is selected, the slider changes to show 0-100%. Move the slider bar to choose a blower motor drive. Most applications will use the Set the flow rate in SLPM option, at a Flow Rate of 15.0 SLPM. 13

15 During typical operation at 15 SLPM, the blower motor drive runs at about 25%. Measured flow is still given in SLPM or LPM. Click Apply to send any changes to the for implementation. Monitoring Flow Rate Flow variables can be monitored in the Main window (below). Click on any variable in the Main window to open the Data Items window, where you can select from Flow Pressure (kpa), Flow Rate (SLPM), Flow Rate (LPM), Flow Power (V), or Flow Drive (%). Flow Pressure (kpa) is equivalent to the Pressure Drop displayed on the control panel. Flow Power (V) is the voltage applied to the blower motor, and is roughly proportional to the Motor Drive (%). Click here and choose from the Data Items window. Flow variables can also be monitored in the Charting window, by choosing the desired variable to be charted along either Y-axis (below). 14

16 Flow Rate Data Output Flow variables can be output via the RS-232 and/or Ethernet ports of the LI-7550 Analyzer Interface Unit. The RS-232 and Ethernet pages are used to set the RS-232 and LI-7200 Ethernet port configuration(s) for unattended data collection. After configuration, click Apply; the LI-7200 will begin to send data out the RS-232 and/or Ethernet ports according to these parameters. If you are connected via the port that you have modified, the settings take effect after you Disconnect from the instrument. If you are connected to the RS-232 port, you can modify the Ethernet settings and click Apply; the changes take effect immediately, and vice versa. 15

17 Flow rate (SLPM or LPM) can also be output via the DAC outputs on the LI-7550 Analyzer Interface Unit. The LI-7550 has the capability to output up to 6 variables on DAC channels 1-6. The DACs page allows you to configure the DAC output channels by specifying the source channel (e.g. Flow Rate, LPM) that drives the analog signal, the source channel value that corresponds to zero volts, and the source channel value that corresponds to full scale voltage (5V). 16

18 For example, to configure DAC #1 to output a voltage signal proportional to Flow Rate (LPM), 18 LPM full scale, select Flow Rate (LPM) under DAC1 'Source', and set 0V = 10, and 5V = 18. 0V 10 5V 18 (X o, zero volts corresponds to 10 LPM) (X F, full scale corresponds to 18 LPM) When a voltage range R is selected, the DAC output voltage V resulting from a Flow Rate value X is given by V R X X o = XF Xo where R = 5V. The DACs are linear, so in the example above, a measured voltage signal of 3 volts would correspond to a Flow Rate value of 14.8 LPM. 17

19 Maintenance Changing the Fuse The fuse in the case can blow if power is applied with reverse polarity. Open the instrument case and unscrew the fuse cover to replace the fuse. The replacement fuse is a 5A fast-blow, 125V, 5x20mm type, available from LI-COR under p/n Figure 6. Unscrew the fuse cover to replace the fuse. Cleaning the Air Filter Screen If the Flow Module is set to maintain flow (e.g. F15.0) and the filter screen becomes clogged with debris, the Motor Drive and Presssure Drop readings will increase, as the motor will have to work harder to maintain the desired flow rate (see Figures 8 and 9 below). If the Flow Module is set to constant blower drive (e.g. C25), the blower drive will remain constant, but the measured flow rate will drop. Unscrew the cap on the filter, remove the screen, and clean with water or compressed air. Clean any remaining debris from the body of the filter, and replace the screen. There is a replacement screen in the spares kit under p/n

20 Figure 7. Remove the cap on the filter and clean the screen with water or compressed air. Figure 8. Plot of pressure drop (kpa) vs. blower drive in During normal operation, the pressure drop is about 1.0 kpa. Typical maximum is about 4.5 kpa at 100% motor drive. 19

21 Figure 9. Plot of power vs. PWM in During normal operation, the operates at about 25% blower drive. As the air filter gets clogged, or the air tubing is kinked, for example, the blower drive percentage rises, requiring more power. 20

22 Specifications Controls: Controlled from LI-7550 via Accessory Cable or via Control Panel. Flow Rate Settings: SLPM (standard liters per minute) setpoint mode or constant blower drive mode. Blower Pressure: 3.5kPa minimum at 100% blower drive at kpa and 300 K ambient. Accessory Link: UART on RS-485 cable. Power Requirements: 50W Maximum Typical <15W@25 C, 15 liters/min. at.75 kpa vacuum VDC Operating Conditions: -20 C to +50 C IEC IP55 specified Designed for outdoor installation Size: x 12.5 x 5.5 (35 cm x 30 cm x 15 cm) (not including mounting hardware). Weight: 13.7 lbs. (6.2 kg). 21

23 Warranty Each LI-COR, inc. instrument is warranted by LI-COR, inc. to be free from defects in material and workmanship; however, LI-COR, inc.'s sole obligation under this warranty shall be to repair or replace any part of the instrument which LI-COR, inc.'s examination discloses to have been defective in material or workmanship without charge and only under the following conditions, which are: 1. The defects are called to the attention of LI-COR, inc. in Lincoln, Nebraska, in writing within one year after the shipping date of the instrument. 2. The instrument has not been maintained, repaired, or altered by anyone who was not approved by LI-COR, inc. 3. The instrument was used in the normal, proper, and ordinary manner and has not been abused, altered, misused, neglected, involved in an accident or damaged by act of God or other casualty. 4. The purchaser, whether it is a DISTRIBUTOR or direct customer of LI-COR or a DISTRIBUTOR'S customer, packs and ships or delivers the instrument to LI-COR, inc. at LI-COR inc.'s factory in Lincoln, Nebraska, U.S.A. within 30 days after LI-COR, inc. has received written notice of the defect. Unless other arrangements have been made in writing, transportation to LI-COR, inc. (by air unless otherwise authorized by LI-COR, inc.) is at customer expense. 5. No-charge repair parts may be sent at LI-COR, inc.'s sole discretion to the purchaser for installation by purchaser. 6. LI-COR, inc.'s liability is limited to repair or replace any part of the instrument without charge if LI-COR, inc.'s examination disclosed that part to have been defective in material or workmanship. There are no warranties, express or implied, including but not limited to any implied warranty of merchantability or fitness for a particular purpose on underwater cables or on expendables such as batteries, lamps, thermocouples and calibrations. Other than the obligation of LI-COR, inc. expressly set forth herein, LI-COR, inc. disclaims all warranties of merchantability or fitness for a particular purpose. The foregoing constitutes LI-COR, inc.'s sole obligation and liability with respect to damages resulting from the use or performance of the instrument and in no event shall LI-COR, inc. or its representatives be liable for damages beyond the price paid for the instrument, or for direct, incidental or consequential damages. The laws of some locations may not allow the exclusion or limitation on implied warranties or on incidental or consequential damages, so the limitations herein may not apply directly. This warranty gives you specific legal rights, and you may already have other rights which vary from location to location. All warranties that apply, whether included by this contract or by law, are limited to the time period of this warranty which is a twelvemonth period commencing from the date the instrument is shipped to a user who is a customer or eighteen months from the date of shipment to LI-COR, inc.'s authorized distributor, whichever is earlier.

24 This warranty supersedes all warranties for products purchased prior to June 1, 1984, unless this warranty is later superseded. To the extent not superseded by the terms of any extended warranty, the terms and conditions of LI-COR s Warranty still apply. DISTRIBUTOR or the DISTRIBUTOR'S customers may ship the instruments directly to LI-COR if they are unable to repair the instrument themselves even though the DISTRIBUTOR has been approved for making such repairs and has agreed with the customer to make such repairs as covered by this limited warranty. Further information concerning this warranty may be obtained by writing or telephoning Warranty manager at LI-COR, inc. IMPORTANT: Please return the User Registration Card enclosed with your shipment so that we have an accurate record of your address. Thank you.

25 Measuring Change in a Changing World 4647 Superior Street P.O. Box 4425 Lincoln, Nebraska North America: International: FAX: envsales@licor.com envsupport@licor.com In Germany LI-COR GmbH: +49 (0) envsales-gmbh@licor.com envsupport-gmbh@licor.com In UK, Ireland, and Scandinavia LI-COR Biosciences UK Ltd.: +44 (0) envsales-uk@licor.com envsupport-uk@licor.com

Power Distribution. Instruction Manual

Power Distribution. Instruction Manual Power Distribution Instruction Manual 7900-230 and 7900-231 Power Distribution Modules Global Headquarters LI-COR Biosciences 4647 Superior Street Lincoln, Nebraska 68504 Phone: +1-402-467-3576 Toll free:

More information

Owner s Manual Nitrate Series Salt Based Filter System

Owner s Manual Nitrate Series Salt Based Filter System Owner s Manual Nitrate Series Salt Based Filter System Page 2 Copyright 2012 Enviro Water Solutions Inc. All rights reserved. All information contained herein is the property of Pelican Water Systems.

More information

DUSTTRAK AEROSOL MONITOR SOLAR POWER KIT MODEL

DUSTTRAK AEROSOL MONITOR SOLAR POWER KIT MODEL DUSTTRAK AEROSOL MONITOR SOLAR POWER KIT MODEL 854060 (USED FOR POWERING ENVIRONMENTAL ENCLOSURE MODELS MODELS 854030, 8535 AND 8537) OPERATION AND MAINTENANCE MANUAL P/N 6008416, REVISION C JUNE 2017

More information

Owner s Manual. Soda Ash ph Neutralizer System

Owner s Manual. Soda Ash ph Neutralizer System Owner s Manual Page 2 Copyright 2011 Enviro Water Solutions Inc. All rights reserved. All information contained herein is the property of Pelican Water Systems. Pelican Water Systems makes no warranty

More information

LU23, LU28 & LU29 Series Quick Start

LU23, LU28 & LU29 Series Quick Start Ultrasonic Liquid Level Transmitter LU23, LU28 & LU29 Series Quick Start 2016 Flowline, Inc. All Rights Reserved Made in USA Flowline, Inc. 10500 Humbolt Street, Los Alamitos, CA 90720 p 562.598.3015 f

More information

LU27 Series Quick Start

LU27 Series Quick Start Ultrasonic Liquid Level Transmitter LU27 Series Quick Start 2016 Flowline, Inc. All Rights Reserved Made in USA Flowline, Inc. 10500 Humbolt Street, Los Alamitos, CA 90720 p 562.598.3015 f 562.431.8507

More information

LoadMaxx. Installation Guide. For Air Ride Trailers. Air-Weigh Customer Support: PN R0

LoadMaxx. Installation Guide. For Air Ride Trailers. Air-Weigh Customer Support: PN R0 LoadMaxx Installation Guide For Air Ride Trailers Air-Weigh Customer Support: 888-459-3247 PN 901-0158-000 R0 x1 Table of Contents LoadMaxx Trailer Overview...1 Installation Overview...1 Mounting the Scale...2

More information

Owner s Manual Pelican Whole House Iron and Manganese Filtration System

Owner s Manual Pelican Whole House Iron and Manganese Filtration System Owner s Manual Pelican Whole House Iron and Manganese Page 2 Copyright 2011 Enviro Water Solutions Inc. All rights reserved. All information contained herein is the property of. makes no warranty of any

More information

PPM EO-100 TM. Operation Manual

PPM EO-100 TM. Operation Manual PPM EO-100 TM Open Loop Electric Prewet Power Module Operation Manual Rev A Page 1 2/23/2010 Copyright 2008 by Cirus Controls, LLC. All Rights Reserved. No part of this material may be reproduced in any

More information

END USER TERMS OF USE

END USER TERMS OF USE END USER TERMS OF USE The following is the End Users Terms of Use as it currently appears in the Mobileye User Manual and Warranty information. This is here for your review and information; it is subject

More information

SOLAR DASH CHARGING SYSTEM USER GUIDE

SOLAR DASH CHARGING SYSTEM USER GUIDE SOLAR DASH CHARGING SYSTEM Doc 1.01 INST049 INSTALLATION STEP 1 Place 20 watt solar panel in the dash of the vehicle facing up. Note: For ideal results position the vehicle in a manner in which the solar

More information

PVI 1800/PVI Residential/Commercial Grid-Tied Photovoltaic Inverter WARRANTY MANUAL. Subject to Change REV , Solectria Renewables

PVI 1800/PVI Residential/Commercial Grid-Tied Photovoltaic Inverter WARRANTY MANUAL. Subject to Change REV , Solectria Renewables PVI 1800/PVI 2500 WARRANTY MANUAL Residential/Commercial Grid-Tied Photovoltaic Inverter 2009, Solectria Renewables Subject to Change REV 10.09 1 Product Warranty & RMA Policy 1.1 Warranty Policy The Solectria

More information

"WHERE TUBING AND FITTINGS COME TOGETHER"

WHERE TUBING AND FITTINGS COME TOGETHER CLEAN ROOM DEVICES, LLC "WHERE TUBING AND FITTINGS COME TOGETHER" CRD200SS TUBE EXPANDER OPERATIONS MANUAL VERSION 4.3 LAST EDITED 06.17.15 cleanroomdevices.com Table of Contents Table of Contents....1

More information

Service Guide JATCO Environmental Protection Tank Model J-7000

Service Guide JATCO Environmental Protection Tank Model J-7000 Service Guide JATCO Environmental Protection Tank Model J-7000 Listed below are a series of steps to follow if the JATCO tank fails to dump properly. #1. Be sure there is an adequate supply of gas pressure

More information

NEO-DYN MODEL 100P ENCLOSURE 7 ADJUSTABLE EXPLOSION-PROOF PRESSURE SWITCH

NEO-DYN MODEL 100P ENCLOSURE 7 ADJUSTABLE EXPLOSION-PROOF PRESSURE SWITCH NEO-DYN MODEL 100P ENCLOSURE 7 ADJUSTABLE EXPLOSION-PROOF PRESSURE SWITCH INSTALLATION AND OPERATION MANUAL PN 610-0006 Rev E WARNING CAUTION SPECIAL CONDITIONS FOR SAFE USE NOTE Manual No. 610-0006 Rev

More information

A Member of the. Integrated Metering Technologies

A Member of the. Integrated Metering Technologies I n s t a l l a t i o n M a n u a l A Member of the Integrated Metering Technologies 1.0 General and safety Do not install, operate or maintain this flow meter without reading, understanding and followingthe

More information

miconverter 18-Module Rack-Mount Power Chassis User Manual 38 Tesla, Irvine, CA USA Phone: (949) ; Fax: (949) Page 12

miconverter 18-Module Rack-Mount Power Chassis User Manual 38 Tesla, Irvine, CA USA Phone: (949) ; Fax: (949) Page 12 miconverter 18-Module Rack-Mount Power Chassis User Manual Page 12 38 Tesla, Irvine, CA 92618 USA Phone: (949) 250-6510; Fax: (949) 250-6514 General and Copyright Notice This publication is protected by

More information

Grape Solar STAR Series Connection Guide Copyright 2012, Grape Solar, Inc. All Rights Reserved

Grape Solar STAR Series Connection Guide Copyright 2012, Grape Solar, Inc. All Rights Reserved Grape Solar STAR Series Connection Guide Copyright 2012, Grape Solar, Inc. All Rights Reserved For more information about this kit, visit http://www.grapesolar.com/manuals.html Series vs. Parallel Connections

More information

Owner s Manual. PS48/PS80 Advantage Series Salt Based Water Softeners

Owner s Manual. PS48/PS80 Advantage Series Salt Based Water Softeners Owner s Manual PS48/PS80 Advantage Series Salt Based Water Softeners Page 2 Copyright 2015 Enviro Water Solutions LLC. All rights reserved. All information contained herein is the property of Pelican Water

More information

series USER MANUAL

series USER MANUAL 888 534-5994 4000 series USER MANUAL Contents Here s all the information you need for setting and operating your new Lathem time recorder. Service information is also included in this manual, in case any

More information

PVI 60KW, PVI 82KW, PVI 95KW

PVI 60KW, PVI 82KW, PVI 95KW PVI 60KW PVI 82KW PVI 95KW WARRANTY MANUAL Commercial, Grid-Tied Photovoltaic Inverters 2008, Solectria Renewables LLC Subject to Change DOC-020099 rev 024 1 1 Product Warranty & RMA Policy Warranty Policy

More information

Instruction Manual DaimlerChrysler Co-Pilot

Instruction Manual DaimlerChrysler Co-Pilot DaimlerChrysler Co-Pilot 3 2 1 13 12 11 10 4 5 6 8 7 Reorder Number Co-Pilot Data Recorder, Deluxe Kit... OT5031A Co-Pilot Data Recorder, Basic Kit... OT5030B Component Reorder Numbers 1. Co-Pilot Data

More information

LI-670. Flow Control Unit. Instruction Manual

LI-670. Flow Control Unit. Instruction Manual LI-670 Flow Control Unit Instruction Manual LI-670 Flow Control Unit Operating and Service Manual NOTICE The information contained in this document is subject to change without notice. LI-COR MAKES NO

More information

Deflection Sensor Installation Guide for welded steer axles Air-Weigh Customer Support:

Deflection Sensor Installation Guide for welded steer axles Air-Weigh Customer Support: PN:901-0146-003 R0 Deflection Sensor Installation Guide for welded steer axles Air-Weigh Customer Support: 888-459-3247 Steer Axle Deflection Sensors See the manuals included with your kit for complete

More information

OnBoard Drum Major Podium

OnBoard Drum Major Podium Assembly and Owner s Manual OnBoard Drum Major Podium CONTENTS CONTENTS................................................................................. 1 SAFETY...................................................................................

More information

Universal Battery Holder Operator s Manual

Universal Battery Holder Operator s Manual Universal Battery Holder Operator s Manual Copyright 2018 Gamry Instruments, Inc. Revision 1.0 August 13, 2018 988-00068 Limited Warranty Gamry Instruments, Inc. warrants to the original user of this product

More information

Owner s Manual. Calcite ph Neutralizer

Owner s Manual. Calcite ph Neutralizer Owner s Manual Page 2 Copyright 2012 Enviro Water Solutions Inc. All rights reserved. All information contained herein is the property of Pelican Water Systems. Pelican Water Systems makes no warranty

More information

WARRANTY POLICY. Grid-Tied Photovoltaic Inverters. Revision D. 2014, Solectria Renewables, LLC DOCIN

WARRANTY POLICY. Grid-Tied Photovoltaic Inverters. Revision D. 2014, Solectria Renewables, LLC DOCIN WARRANTY POLICY Revision D 2014, Solectria Renewables, LLC DOCIN-070360 1 Product Warranty & RMA Policy 1. Warranty Policy Warranty Registration: It is important to have updated information about the inverter

More information

Model Combustible Gas Sample Draw Detector Head Operator s Manual

Model Combustible Gas Sample Draw Detector Head Operator s Manual Model 1017-01 Combustible Gas Sample Draw Detector Head Operator s Manual Part Number: 71-0058RK Revision: B Released: 5/24/13 www.rkiinstruments.com WARNING Read and understand this instruction manual

More information

MEX (55) QRO (442) Web Controls

MEX (55) QRO (442) Web Controls Web Controls SINGLE AND DUAL ROTOR TENSION CONTROL BRAKES MODELS:,,,, AND INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS Read this manual carefully, making full use of its explanations and instructions.

More information

A Member of the. Integrated Metering Technologies

A Member of the. Integrated Metering Technologies I n s t a l l a t i o n M a n u a l A Member of the Integrated Metering Technologies 1.0 General and Safety Do not install, operate or maintain this flow meter without reading, understanding and followingthe

More information

LUBRICATOR GUN INSTRUCTIONS-PARTS LIST. 10,000 psi (700 bar) Maximum Delivery Pressure. Detachable-type

LUBRICATOR GUN INSTRUCTIONS-PARTS LIST. 10,000 psi (700 bar) Maximum Delivery Pressure. Detachable-type INSTRUCTIONS-PARTS LIST 306 460 INSTRUCTIONS This manual contains important warnings and information. READ AND KEEP FOR REFERENCE. Rev. E Supercedes D Detachable-type LUBRICATOR GUN 10,000 psi (700 bar)

More information

AC Irrigation and Propagation Controllers I Four Station, 5006-I and 5006-IP Six Station

AC Irrigation and Propagation Controllers I Four Station, 5006-I and 5006-IP Six Station AC Irrigation and Propagation Controllers 5004-I Four Station, 5006-I and 5006-IP Six Station I N S T R U C T I O N M A N U A L Table of contents Introduction 1 1. Specifications 1 2. Controller Mounting

More information

Model 809 Diaphragm Gauge Controller

Model 809 Diaphragm Gauge Controller Instruction Manual Model 809 Diaphragm Gauge Controller Copyright 2004 by Duniway Stockroom Corp. rev120313sr TELEPHONE: 650-969-8811 TOLL-FREE: 800-446-8811 FAX: 650-965-0764 WWW.DUNIWAY.COM 1 of 17 Table

More information

Pressure Transducer Field Installation Instructions for the LI-6252 CO 2 and LI-6262 CO 2 /H 2 O Analyzers

Pressure Transducer Field Installation Instructions for the LI-6252 CO 2 and LI-6262 CO 2 /H 2 O Analyzers 6262-05 6262-03 Pressure Transducer Field Installation Instructions for the LI-6252 CO 2 and LI-6262 CO 2 /H 2 O Analyzers Please read these instructions before beginning installation. Please note that

More information

Tracer VMA with AutoReg

Tracer VMA with AutoReg Tracer with AutoReg Flowmeter with Automatic Flow Regulation Operating Instructions RoHS Compliant General The Tracer Flowmeter with AutoReg provides: Analog Flow Output (Selectable 0 to 3.5V, 0 to 5V

More information

Humidity Monitor model 00619

Humidity Monitor model 00619 Instruction Manual Humidity Monitor model 00619 CONTENTS Unpacking Instructions...2 Package Contents...2 Product Registration...2 Features & Benefits...3 Setup...3 Measurement Units...4 Placement Guidelines...4

More information

Lubricator Gun: 10,000 psi (700 bar) Maximum Delivery Pressure when disconnected from Dispenser

Lubricator Gun: 10,000 psi (700 bar) Maximum Delivery Pressure when disconnected from Dispenser INSTRUCTIONS-PARTS LIST 30 455 INSTRUCTIONS This manual contains important warnings and information. READ AND KEEP FOR REFERENCE. Rev. C Supercedes B Hand-Operated Portable Grease Dispenser Buckshot Luber

More information

i n s t r u c t i o n m a n u a l

i n s t r u c t i o n m a n u a l i n s t r u c t i o n m a n u a l 8006 Six-Station AC Timer Residential/Light Commercial Independent Program Irrigation Controllers Installation, Programming and Operating Instructions Features Operates

More information

Premium Wooden Piano Bench with Adjustable Height

Premium Wooden Piano Bench with Adjustable Height Premium Wooden Piano Bench with Adjustable Height Thank you for choosing Auray. This elegant, concert-style piano bench is ideal for stage performance, studio sessions, or home use. It features genuine

More information

ST-70 CONTROL OPERATING MANUAL REVISION DATE: PART#:

ST-70 CONTROL OPERATING MANUAL REVISION DATE: PART#: ST-70 CONTROL OPERATING MANUAL REVISION DATE: 05-15-07 PART#: 98-0002-09 SERVICE & CUSTOMER INFORMATION CUSTOMER MUST HAVE PART NUMBER WHEN ORDERING ITEMS THROUGH THE SERVICE DEPARTMENT. IF FURTHER HELP

More information

Smart Battery Charger GPC-35-MAX GPC-45-MAX GPC-55-MAX GPC-75-MAX GPC-100-MAX. Owner s Manual

Smart Battery Charger GPC-35-MAX GPC-45-MAX GPC-55-MAX GPC-75-MAX GPC-100-MAX. Owner s Manual Smart Battery Charger GPC-35-MAX GPC-45-MAX GPC-55-MAX GPC-75-MAX GPC-100-MAX Owner s Manual Table of Contents Important Safety Instructions 2 Features 3 Installation Guidelines 5 Warranty 8 1.0 Important

More information

TAILGATE SPREADER INSTALLATION & OWNER S MANUAL TABLE OF CONTENTS

TAILGATE SPREADER INSTALLATION & OWNER S MANUAL TABLE OF CONTENTS A Division of Northern Star Industries, Inc. P.O. Box 788 Iron Mountain MI 49801-0788 www.bossplow.com SMARTHITCH 1100 TAILGATE SPREADER INSTALLATION & OWNER S MANUAL TABLE OF CONTENTS S & CAUTIONS...

More information

NEO-DYN MODELS 100T AND 100TC ADJUSTABLE TEMPERATURE SWITCHES; ENCLOSURE 3X FOR WEATHERPROOF APPLICATIONS INSTALLATION AND OPERATION MANUAL

NEO-DYN MODELS 100T AND 100TC ADJUSTABLE TEMPERATURE SWITCHES; ENCLOSURE 3X FOR WEATHERPROOF APPLICATIONS INSTALLATION AND OPERATION MANUAL NEO-DYN MODELS 100T AND 100TC ADJUSTABLE TEMPERATURE SWITCHES; ENCLOSURE 3X FOR WEATHERPROOF APPLICATIONS INSTALLATION AND OPERATION MANUAL PN 610-0012 Rev B Manual No. 610-0012 REV B Neo-Dyn 28150 Industry

More information

OWNER S MANUAL. Model 9880 Intrinsically Safe Air Velocity Meter

OWNER S MANUAL. Model 9880 Intrinsically Safe Air Velocity Meter OWNER S MANUAL Model 9880 Intrinsically Safe Air Velocity Meter LIMITATION OF WARRANTY AND LIABILITY Seller warrants the goods sold hereunder, under normal use and service as described in the operator's

More information

This document describes:

This document describes: Thank you for purchasing this product from ERM Products. We appreciate your interest in our unique product line as we try to offer our customers an alternative to today s traditional products. This universal

More information

Installation & Operators Manual

Installation & Operators Manual Installation & Operators Manual Model Serial Number Purchase Date 2007-2008 SegVator, LLC Patent Pending All Rights Reserved Important Safety Information Make sure the vehicle has a properly installed

More information

Flo-Way. Measure Granular or Powdered Material. Stand Alone or Connect to Other Devices for Blending. Used by Successful Producers World-Wide

Flo-Way. Measure Granular or Powdered Material. Stand Alone or Connect to Other Devices for Blending. Used by Successful Producers World-Wide Flo-Way R Solids Impact Flow Meter Measure Granular or Powdered Material Stand Alone or Connect to Other Devices for Blending Used by Successful Producers World-Wide Visit our website: www.beltwayscales.com

More information

INDOOR LED BAR DIGIT HOCKEY SCOREBOARD INSTRUCTION MANUAL REVISION DATE: PART#:

INDOOR LED BAR DIGIT HOCKEY SCOREBOARD INSTRUCTION MANUAL REVISION DATE: PART#: INDOOR LED BAR DIGIT HOCKEY SCOREBOARD INSTRUCTION MANUAL REVISION DATE: 02-02-09 PART#: 98-0006-05 SERVICE & CUSTOMER INFORMATION CUSTOMER MUST HAVE PART NUMBER WHEN ORDERING ITEMS THROUGH THE SERVICE

More information

Model Combustible Gas Sample Draw Detector Head Operator s Manual

Model Combustible Gas Sample Draw Detector Head Operator s Manual Model 1017-06 Combustible Gas Sample Draw Detector Head Operator s Manual Part Number: 71-0356 Revision: P1 Released: 2/4/15 www.rkiinstruments.com WARNING Read and understand this instruction manual before

More information

Installation Instructions

Installation Instructions 85-3214 rev. 07 03-11 Installation Instructions Thank you for purchasing this anti-sway bar kit. Please read through these instructions before installation. Rear Anti-Sway Bar Kit Freightliner FL Series

More information

AEROMOTIVE Part # L Mustang Digital FMU INSTALLATION INSTRUCTIONS

AEROMOTIVE Part # L Mustang Digital FMU INSTALLATION INSTRUCTIONS AEROMOTIVE Part # 17113 4.6L Mustang Digital FMU INSTALLATION INSTRUCTIONS CAUTION: Installation of this product requires detailed knowledge of automotive systems and repair procedures. We recommend that

More information

This document describes:

This document describes: Thank you for purchasing this product from ERM. We appreciate your interest in our unique product line as we try to offer our customers an alternative to today s traditional products. This programmable

More information

Model 2008 I Battery Operated Irrigation Timer with 3/4 in. Anti-Siphon Valve

Model 2008 I Battery Operated Irrigation Timer with 3/4 in. Anti-Siphon Valve i n s t r u c t i o n m a n u a l Model 2008 I Battery Operated Irrigation Timer with 3/4 in. Anti-Siphon Valve Features Weekly or cyclical programming 4 start times per day in weekly program Irrigation

More information

Model AS-RC3260 TV Cart. Rolling Cart for Audio Mount System & Flat Panel TVs

Model AS-RC3260 TV Cart. Rolling Cart for Audio Mount System & Flat Panel TVs Model AS-RC3260 TV Cart Rolling Cart for Audio Mount System & Flat Panel TVs GETTING STARTED Introduction Congratulations on the purchase of your new Helios AS-RC3260 Rolling Cart. For maximum benefit,

More information

SUNTURA SOLAR TRACKER

SUNTURA SOLAR TRACKER WindyNation SUNTURA SOLAR TRACKER SOT-TRKS-NF User s Manual Page 1 of 10 WindyNation 08/09/2012 Table of Contents 1 Introduction... 3 1.1 Limited Warranty... 3 1.2 Restrictions... 3 1.3 Warranty Claims

More information

Installation & Operation Manual. Electrak 100 Series / Electromechanical Linear Actuator

Installation & Operation Manual. Electrak 100 Series / Electromechanical Linear Actuator www..c Installation & Operation Manual Electrak 100 Series / Electromechanical Linear Actuator Thomson has many years of experience designing and manufacturing linear actuators for a wide variety of applications

More information

i n s t r u c t i o n m a n u a l

i n s t r u c t i o n m a n u a l i n s t r u c t i o n m a n u a l Model 7001 Battery Operated Irrigation Controller with Hose or Pipe Thread Features Weekly or cyclical programming 4 start times per day in weekly program Irrigation duration

More information

Product Name: Product Description: Product Number: Comp-Gate40 40mm External TS-0505-1XXX ------------------------------------------------------------------------------------------------------------------------

More information

Model C230 Pump Controller

Model C230 Pump Controller MANUAL Model C230 Earthsafe Systems, Inc. 7553 S. Madison Willowbrook, IL 60527 T: (630) 794-5100 F: (630) 794-5106 info@earthsafe.com www.earthsafe.com March 1, 2010 The information contained herein is

More information

EAGL 1-Touch Laser Level

EAGL 1-Touch Laser Level EAGL 1-Touch Laser Level Owner s Manual GENERAL INFORMATION Thank you for buying the EAGL 1-Touch laser. Although it is very simple to use, we recommend that you read this manual before operating the laser.

More information

StormPro BA Series Sump Pump

StormPro BA Series Sump Pump Page 1 of 8 Marks & Meanings DANGER: Keep the pump equipment out of the reach of children! Warns that the failure to follow the directions given could cause serious risk to individuals or objects. WARNING:

More information

INSTRUCTION MANUAL. Model 7001 Battery Operated Irrigation Controller with Hose or Pipe Thread

INSTRUCTION MANUAL. Model 7001 Battery Operated Irrigation Controller with Hose or Pipe Thread DIG CORPORATION 3 YEAR WARRANTY DIG CORPORATION warrants these products to be free from defects in material and workmanship for a period of three years from date of purchase. This warranty does not cover

More information

Installation Instructions

Installation Instructions 85-4592 rev. 08 02-18 Installation Instructions Thank you for purchasing our sway bar kit. Please read through these instructions before installation. Auxiliary Rear Anti-Sway Bar Kit for Ford F53 part

More information

CRD610 Automatic Fitting Inserter

CRD610 Automatic Fitting Inserter CRD610 Automatic Fitting Inserter OPERATIONS MANUAL VERSION 1.2 LAST EDITED 12.12.2018 cleanroomdevices.com 1 Table of Contents Title Page. 1 Table of Contents...2 1.0 General Product & Safety Information....3

More information

AGCO. Corn Header Manual d HEADSIGHT.COM

AGCO. Corn Header Manual d HEADSIGHT.COM AGCO Corn Header Manual 09020401d HEADSIGHT.COM 574.546.5022 About Headsight Headsight Contact Info Headsight, Inc. 4845 3B Road Bremen, IN 46506 Phone: 574-546-5022 Fax: 574-546-5760 Email: info@headsight.com

More information

RAM 1500, 2019 CLASSIC & 2010-ON 2500/3500 INSTALLATION INSTRUCTIONS

RAM 1500, 2019 CLASSIC & 2010-ON 2500/3500 INSTALLATION INSTRUCTIONS 2009-18 RAM 1500, 2019 CLASSIC & 2010-ON 2500/3500 INSTALLATION INSTRUCTIONS Thank you for purchasing ROCKSTARTM Splash Guard Mud Flaps. Agri-Cover, Inc. proudly manufactured these mud flaps using superior

More information

YAMAHA MOTOR CORPORATION, U.S.A. MZ-SERIES ENGINES 3-YEAR LIMITED WARRANTY

YAMAHA MOTOR CORPORATION, U.S.A. MZ-SERIES ENGINES 3-YEAR LIMITED WARRANTY Yamaha Motor Corporation, U.S.A., hereby warrants that new Yamaha MZ-series Spark Ignited Small Off Road Engines, hereafter called SORE engines, purchased from an authorized Yamaha SORE engine dealer in

More information

Manufacturing Facility is ISO9001:2000. Welded Steel Pipe Conform to ASTM A53. Threads Conform to ASME B1.20.1

Manufacturing Facility is ISO9001:2000. Welded Steel Pipe Conform to ASTM A53. Threads Conform to ASME B1.20.1 STEEL NIPPLES S40 & S80 Steel Nipple Product Specifications Manufacturing Facility is ISO9001:2000 Welded Steel Pipe Conform to ASTM A53 Threads Conform to ASME B1.20.1 800-678-2544 800-678-0857 www.msi-products.com

More information

Installation Instructions

Installation Instructions 85-3195 rev. 12 04-18 Installation Instructions Thank you for purchasing this antisway bar kit. Please read through these instructions before installation. Part #1139-117 Rear Anti-Sway Bar Kit 1½ diameter

More information

II DISTRIBUTION & SUBSTATION TYPE C

II DISTRIBUTION & SUBSTATION TYPE C CapCheckIII DISTRIBUTION & SUBSTATION TYPE Ca p a c i t o r C h e c ke r Operating & Instruction Manual 1475 Lakeside Drive Waukegan, Illinois 60085 U.S.A. 847.473.4980 f a x 8 4 7. 4 7 3. 4 9 8 1 w e

More information

Pro-Series/ Electromechanical Linear Actuator

Pro-Series/ Electromechanical Linear Actuator Pro-Series/ Electromechanical Linear Actuator Installation and Operation Manual P-264-PROSERIES (08/10) Keep all product manuals as a product component during the life span of the product. Pass all product

More information

Getz Equipment Innovators 450 lb Portable / Wheeled Unit Dry Chemical Fill System Part No: 3G0061/3G0063

Getz Equipment Innovators 450 lb Portable / Wheeled Unit Dry Chemical Fill System Part No: 3G0061/3G0063 Getz Equipment Innovators 450 lb Portable / Wheeled Unit Dry Chemical Fill System Part No: 3G0061/3G0063 1 Revised 4/12/17 2320 Lakecrest Drive, Pekin IL 61554 PH. (888) 747-4389 Fax (309) 495-0625 Website:

More information

Model Series. PumpAgents.com - buy pumps and parts online ELECTRIC BILGE PUMPS. Model Series FEATURES SPECIFICATIONS STANDARD MODELS

Model Series. PumpAgents.com - buy pumps and parts online ELECTRIC BILGE PUMPS. Model Series FEATURES SPECIFICATIONS STANDARD MODELS PumpAgents.com - Click here for Pricing/Ordering Model 36600-Series ELECTRIC BILGE PUMPS FEATURES Self-Priming Diaphragm Design Allows Dry Running Quiet Operation Built-in Hydraulic Pulsation Dampener

More information

HATCHGRIP Installation Instructions/Operation and Maintenance Manual

HATCHGRIP Installation Instructions/Operation and Maintenance Manual HATCHGRIP Installation Instructions/Operation and Maintenance Manual Models: HTG-PCG Contact Information Table of Contents: Safety Precautions... 2 Product Information... 2 Operation... 3 Installation

More information

Parts Manual Vermeer/ McLaughlin Mud System 230P

Parts Manual Vermeer/ McLaughlin Mud System 230P 2006 Perimeter Road. Greenville, SC 29605 Toll Free: 800/435-9340 - Phone: 864/277-5870 Fax: 864/235-9661 - Website address: www.mightymole.com Email address: mmole@mightymole.com Parts Manual Vermeer/

More information

SUNTURA HD SOLAR TRACKER

SUNTURA HD SOLAR TRACKER WindyNation SUNTURA HD SOLAR TRACKER SOT-TRKS-NFHD User s Manual Page 1 of 11 WindyNation 08/09/2012 Table of Contents 1! Introduction... 3! 1.1! Limited Warranty... 3! 1.2! Restrictions... 3! 1.3! Warranty

More information

Installation Guide. Spring Steer Suspensions. Air-Weigh Customer Support: Welded Steer Brackets PN R0

Installation Guide. Spring Steer Suspensions. Air-Weigh Customer Support: Welded Steer Brackets PN R0 Installation Guide Spring Steer Suspensions Welded Steer Brackets Air-Weigh Customer Support: 888-459-3247 PN 901-0146-003 R0 1 Table of Contents Overview...1 Tools Required...1 Installing the Sensor Bracket...2

More information

Model Combustible Gas Sample Draw Detector Head Operator s Manual

Model Combustible Gas Sample Draw Detector Head Operator s Manual Model 1017-07 Combustible Gas Sample Draw Detector Head Operator s Manual Part Number: 71-0480 Revision: P1 Released: 1/4/19 www.rkiinstruments.com WARNING Read and understand this instruction manual before

More information

10 Year Limited Warranty

10 Year Limited Warranty Power. On Your Terms. 10 Year Limited Warranty PHI 2.7 TM PHI 3.5 TM 60A SIMPLIPHI POWER, INC. REV020618 10 Year Limited Warranty: PHI 2.7 TM PHI 3.5 TM 60A 24V 48V Limited Pro-Rated Warranty Coverage

More information

User s Manual for Tennessee Chill Box System P/N CB8000

User s Manual for Tennessee Chill Box System P/N CB8000 User s Manual for Tennessee Chill Box System P/N CB8000 Read and understand all instructions before using this product. Open carton carefully and inspect product for damage caused by carrier. If any damage

More information

Parts Manual V100G Vacuum Machine Part #E (SERIAL #1G G )

Parts Manual V100G Vacuum Machine Part #E (SERIAL #1G G ) 2006 Perimeter Road. Greenville, SC 29605 Toll Free: 800/435-9340 - Phone: 864/277-5870 Fax: 864/235-9661 - Website address: www.mightymole.com Email address: mmole@mightymole.com Parts Manual V100G Vacuum

More information

ADJUSTABLE COMFORT ASSEMBLY INSTRUCTIONS

ADJUSTABLE COMFORT ASSEMBLY INSTRUCTIONS ASSEMBLY INSTRUCTIONS ASSEMBLY INSTRUCTIONS For customer service call 1-877-707-7533 or email azcustomerservice@classicbrands.org STEP 1: Carefully open the carton and remove all boxes then lay out the

More information

Power. On Your Terms.

Power. On Your Terms. Power. On Your Terms. 10 YEAR LIMITED WARRANTY PHI 1310 TM 1 SIMPLIPHI POWER, INC. REV102016 10 YEAR LIMITED WARRANTY: PHI 1310 TM LIMITED PRO-RATED WARRANTY COVERAGE The SimpliPhi Power PHI 1310 as supplied

More information

UNIVERSAL CUSTOMIZABLE MUD FLAP INSTALLATION INSTRUCTIONS

UNIVERSAL CUSTOMIZABLE MUD FLAP INSTALLATION INSTRUCTIONS UNIVERSAL CUSTOMIZABLE MUD FLAP INSTALLATION INSTRUCTIONS Thank you for purchasing ROCKSTARTM Splash Guard Mud Flaps. Agri-Cover, Inc. proudly manufactured these mud flaps using superior quality materials

More information

INSTALLATION INSTRUCTIONS AND OWNER S MANUAL

INSTALLATION INSTRUCTIONS AND OWNER S MANUAL INSTALLATION INSTRUCTIONS AND OWNER S MANUAL Thank you for purchasing ADARAC Truck Bed Rack. Agri-Cover, Inc. proudly manufactured this product using superior quality materials and workmanship. With proper

More information

SPC Series. Digital Scale. Operation Manual

SPC Series. Digital Scale. Operation Manual SPC Series Digital Scale Operation Manual Revision 1.0 August 17, 2000 ! WARNING Use only the AC adapter which comes with the scale. Other adapters may cause damage. Internal service to this product should

More information

GC-1. Roof and Gutter De-Icing Control Installation and Operating Instructions FOR EXTERIOR INSTALLATION ONLY

GC-1. Roof and Gutter De-Icing Control Installation and Operating Instructions FOR EXTERIOR INSTALLATION ONLY GC-1 Roof and Gutter De-Icing Control Installation and Operating Instructions FOR EXTERIOR INSTALLATION ONLY GENERAL INFORMATION The GC-1 heating cable controller has been designed and manufactured for

More information

Installation Instructions

Installation Instructions 85-3511 rev. 04 11-15 Installation Instructions Polyurethane Bushing Kit for Ford F-53 (Front) (replaces OE bushings and brackets) part #4139-127 1-5/8 diameter INTRODUCTION Thank you for purchasing this

More information

Nortec EL SPARE PARTS LIST. Contents. IMPORTANT! This document to be left with the equipment.

Nortec EL SPARE PARTS LIST. Contents. IMPORTANT! This document to be left with the equipment. 2582959_C_EN_608 Nortec EL SPARE PARTS LIST Proprietary Notice This document and the information disclosed herein are proprietary data of Nortec Humidity Ltd. Neither this document nor the information

More information

4-SIDED BASKETBALL SCOREBOARD LED BAR DIGIT INSTRUCTION MANUAL REVISION DATE: PART#:

4-SIDED BASKETBALL SCOREBOARD LED BAR DIGIT INSTRUCTION MANUAL REVISION DATE: PART#: 4-SIDED BASKETBALL SCOREBOARD LED BAR DIGIT INSTRUCTION MANUAL REVISION DATE: 12-04-07 PART#: 98-0001-09 SERVICE & CUSTOMER INFORMATION CUSTOMER MUST HAVE PART NUMBER WHEN ORDERING ITEMS THROUGH THE SERVICE

More information

INSTALLATION, INSTRUCTION AND SERVICE MANUAL

INSTALLATION, INSTRUCTION AND SERVICE MANUAL INSTALLATION, INSTRUCTION AND SERVICE MANUAL Actuator/Brake/Trailer Dealer Please provide to consumer. Consumer Read and follow instructions. Keep with trailer for reference. Page 1 of 7 1. Introduction...

More information

Installation / Operation Instructions Sunnex ORION Series Exam Lights

Installation / Operation Instructions Sunnex ORION Series Exam Lights Installation / Operation Instructions Sunnex ORION Series Exam Lights OR-120 OR-127 OR-220 OR-227 Models: OR-300 OR-400 OR-500 OR-600 1. APPLICATIONS The Sunnex ORION Series light was designed specifically

More information

RK Standby Battery Operator s Manual

RK Standby Battery Operator s Manual 49-8104RK Standby Battery Operator s Manual Part Number: 71-0118RK Revision: C Released: 8/4/17 www.rkiinstruments.com Product Warranty RKI Instruments, Inc. warrants gas alarm equipment sold by us to

More information

12-in-1 CABLE TESTER. User Manual CBT-12

12-in-1 CABLE TESTER. User Manual CBT-12 12-in-1 CABLE TESTER User Manual CBT-12 Thank you for choosing Kopul. The Kopul CBT-12 is a professional-quality cable tester that allows users to test the continuity of a wide variety of cables with a

More information

Watts Series CSM-61. Flow Measurement/Balancing Valves Sizes: 1 1 4", 1 1 2", 2", 2 1 2", and 3" (32, 40, 50, 65 and 80mm) Installation Instructions

Watts Series CSM-61. Flow Measurement/Balancing Valves Sizes: 1 1 4, 1 1 2, 2, 2 1 2, and 3 (32, 40, 50, 65 and 80mm) Installation Instructions Watts Series CSM-61 Measurement/Balancing Valves Sizes: 1 1 4", 1 1 2", 2", 2 1 2", and 3" (32, 4, 5, 65 and 8mm) Installation Instructions IS-CSM-61-L Watts Measurement/Balancing Valves are available

More information

Model 8340 Intrinsically Safe VELOCICHECK Air Velocity Meter

Model 8340 Intrinsically Safe VELOCICHECK Air Velocity Meter Ventilation Testing/Balancing Model 8340 Intrinsically Safe VELOCICHECK Air Velocity Meter Operation and Service Manual 1980076, Revision E October 2002 Model 8340 Intrinsically Safe VELOCICHECK Air Velocity

More information

Professional Weather Center

Professional Weather Center Instruction Manual Professional Weather Center CONTENTS Unpacking Instructions... 2 Package Contents... 2 Product Registration... 2... 3... 4... 6 Setup... 7 5-in-1 Sensor Setup... 7... 8... 9... 9...10...

More information

Pivot Arm 20 Adjustable Wheel Lock Control INSTRUCTIONS

Pivot Arm 20 Adjustable Wheel Lock Control INSTRUCTIONS Pivot Arm 20 Adjustable Wheel Lock Control INSTRUCTIONS Introduction Thank you for choosing Impact. The Impact Pivot Arm 20 with Adjustable Wheel Lock Control is a strong mounting arm with an elbow pivot

More information

Parts Manual V100G Vacuum Machine Part #E (SERIAL #1G G )

Parts Manual V100G Vacuum Machine Part #E (SERIAL #1G G ) 2006 Perimeter Road. Greenville, SC 29605 Toll Free: 800/435-9340 - Phone: 864/277-5870 Fax: 864/235-9661 - Website address: www.mightymole.com Email address: mmole@mightymole.com Parts Manual V100G Vacuum

More information