us cables New! chainflex guarantee club Guaranteed lifetime Selection table page 154 CFBUS.PVC PVC 12,5-5/
|
|
- Jonathan Hodges
- 5 years ago
- Views:
Transcription
1 chainflex type chainflex cable Jacket Shield Min. bending radius, moved [factor x d] Temperature, moved from/to [ C] Approvals and standards Oil-resistant Torsion resistant v max. [m/s] unsupported v max. [m/s] gliding a max. [m/s 2 ] Page Bus cables New! chainflex guarantee club Guaranteed lifetime Selection table page 4 us cables Selection chart for chainflex bus cables 6 CFBUS.PVC PVC -5/ CFBUS.PUR PUR -20/ CFBUS / CF11.LC 10-35/ CF11.LC.D 10-35/ CF14.CAT /
2 chainflex guarantee club Guaranteed lifetime (1) New! chainflex cables Bus cables CFBUS.PVC CFBUS.PUR CFBUS CFBUS CF11.LC CF11.LC.D CF14.CAT5 Temperature, from/to [ C] -5 / / / / / / / / / +60 v max. [m/s] unsupported gliding a max. [m/s 2 ] Travel distance [m] Bending radius min. [factor x d] < 10 m 10 m 5 million double strokes * Bending radius min. [factor x d] < 10 m 10 m 7,5 million double strokes * (1) New! Guaranteed lifetime for these series according to the "chainflex guarantee club" conditions Page * Guaranteed lifetime, higher number of double strokes possible. Bending radius min. [factor x d] < 10 m 10 m 10 million double strokes * Page
3 chainflex Bus cable Selection chainflex bus cables chainflex Bus cable Bus system/ chainflex type Number of cores and conductor nominal cross section [mm 2 ] Min. bending radius, moved Temperature, moved from/to [ C] 0 Ohm CFBUS.PVC.001 (2x0,25)C x d PVC - 5 C / +70 C* Class CFBUS.PUR.001 (2x0,25)C x d PUR - 20 C / +70 C Class CFBUS.001 (2x0,25)C 10 x d - 35 C / +70 C Class CF PBA.LC.D (2x0,25)C 10 x d - 35 C / +70 C Class CFROBOT8.001 (2x0,35)C 10 x d PUR - 20 C / +70 C Class twisted CFBUS.002 (2x0,25)C+4x1,5 10 x d - 35 C / +70 C Class CF PBA.LC.D (2x0,25)C+4x1,5 10 x d - 35 C / +70 C Class CFBUS.003 (2x0,25)C+3x0,75 10 x d - 35 C / +70 C Class CF PBA.LC.D (2x0,25)C+3x0,75 10 x d - 35 C / +70 C Class CF PBA.LC (2x(2x0,25))C 10 x d - 35 C / +70 C Class Interbus Ohm CFBUS.010 (3x(2x0,25))C 10 x d - 35 C / +70 C Class CF IB-S (3x(2x0,25))C 10 x d - 35 C / +70 C Class CFBUS.011 (3x2x0,25+3x1,0)C 10 x d - 35 C / +70 C Class CF IB-S (3x2x0,25+3x1,0)C 10 x d - 35 C / +70 C Class Ohm CFBUS.020 (4x0,25)C 10 x d - 35 C / +70 C Class CF LC.D (4x0,25)C 10 x d - 35 C / +70 C Class CFBUS.PVC.021 (2x0,5)C x d PVC - 5 C / +70 C* Class CFBUS.PUR.021 (2x0,5)C x d PUR - 20 C / +70 C Class CFBUS.021 (2x0,5)C 10 x d - 35 C / +70 C Class CF LC (2x0,5)C 10 x d - 35 C / +70 C Class CF LC.D (2x0,5)C 10 x d - 35 C / +70 C Class CFBUS.PVC.022 (4x0,5)C x d PVC - 5 C / +70 C* Class CFBUS.PUR.022 (4x0,5)C x d PUR - 20 C / +70 C Class CFBUS.022 (4x0,5)C 10 x d - 35 C / +70 C Class CF LC (4x0,5)C 10 x d - 35 C / +70 C Class CFROBOT8.022 (4x0,5)C 10 x d PUR - 20 C / +70 C Class twisted Device-Net Ohm CFBUS.030 ((2xAWG 24)C+2xAWG 22)C 10 x d - 35 C / +70 C Class CFBUS.031 ((2xAWG 18)C+2xAWG )C 10 x d - 35 C / +70 C Class * -5 C to +70 C following DIN EN 60811, part 1-4 chapter 8.2, +5 C to +70 C for use in energy chains with > cycles Jacket UV-resistant Halogen-free Unsupported Class Approvals and standards Page Gliding More bus systems Page 8 6 7
4 chainflex Bus cable Selection chainflex bus cables chainflex Bus cable Bus system/ chainflex type Number of cores and conductor nominal cross section [mm 2 ] Min. bending radius, moved Temperature, moved from/to [ C] CC-Link 110 Ohm CFBUS.035 (3xAWG20)C 10 x d - 35 C / +70 C Class Ethernet/CAT5/GigE Ohm CFBUS.040 (4x0,25)C 10 x d - 35 C / +70 C Class CF CAT5 (4x0,25)C 10 x d - 35 C / +70 C Class CFBUS.041 (4x(2x0,25))C 10 x d - 35 C / +70 C Class CF CAT5 (4x(2x0,25))C 10 x d - 35 C / +70 C Class CFBUS.042 (5x(2x0,25))C 10 x d - 35 C / +70 C Class CF CAT5 (5x(2x0,25))C 10 x d - 35 C / +70 C Class CFBUS.PVC.045 (4x(2x0,))C x d PVC - 5 C / +70 C* Class CFBUS.PUR.045 (4x(2x0,))C x d PUR - 20 C / +70 C Class CFBUS.044 (4x(2x0,))C 10 x d - 35 C / +70 C Class CFBUS.045 (4x(2x0,))C 10 x d - 35 C / +70 C Class CF CAT5 (4x(2x0,14))C 10 x d - 35 C / +70 C Class CFROBOT x(2x0,14)C 10 x d PUR - 20 C / +70 C Class twisted CFSPECIAL (4x(2x0,))C 10 x d PUR - 20 C / +70 C Ethernet/CAT6 A Ohm CFBUS.PVC.050 4x(2x0,2)C x d PVC - 5 C / +70 C* Class CFBUS.PUR.050 4x(2x0,2)C x d PUR - 20 C / +70 C Class CFBUS.050 (4x(2x0,)C)C x d - 35 C / +70 C Class FireWire IEEE 1394a/b Ohm CFBUS.055 (2x(2x0,)C+2x(0,34)C) x d - 35 C / +70 C Class CFBUS.PVC.056 (2x(2x0,)C+2x0,38)C x d PVC - 5 C / +70 C* Class CFBUS.PUR.056 (2x(2x0,)C+2x0,38)C x d PUR - 20 C / +70 C Class Profinet Ohm CFBUS.PVC.060 (4x0,38)C x d PVC - 5 C / +70 C* Class CFBUS.PUR.060 (4x0,38)C x d PUR - 20 C / +70 C Class CFBUS.060 (4x0,38)C x d - 35 C / +70 C Class CFROBOT8.060 (2x(2x0,34))C 10 x d PUR -20 C / +70 C Class twisted USB 90 Ohm CFBUS.065 ((2xAWG28)+2xAWG20)C x d - 35 C / +70 C Class CFBUS.066 ((2xAWG24)+2xAWG20)C x d - 35 C / +70 C Class USB Ohm CFBUS.PVC.068 (2x(2xAWG28)+2x(2xAWG28)C)C x d PVC - 5 C / +70 C* Class CFBUS.PUR.068 (2x(2xAWG28)+2x(2xAWG28)C)C x d PUR - 20 C / +70 C Class DVI Ohm CFBUS.070 (4x(2xAWG28)C+(2xAWG28)+3xAWG28)C x d - 35 C / +70 C Class * -5 C to +70 C following DIN EN 60811, part 1-4 chapter 8.2, +5 C to +70 C for use in energy chains with > cycles Jacket UV-resistant Halogen-free Unsupported Class Approvals and standards Page Gliding More bus systems Page 6 8 9
5 CFBUS.PVC PVC x d PVC Bus cable CFBUS.PVC Class (4 medium load requirements 2 travel distance up to 20 m 2 oil-resistant) CFBUS.PVC PVC x d for medium load requirements PVC outer jacket shielded oil-resistant flame-retardant UL/CSA Style 98 and 2571, 30 V, 80 C NFPA Following NFPA chapter 12.9 CEI Following CEI CE Following 2006/95/EG Conductor Core insulation Core stranding Stranded conductor in especially bending-resistant version consisting of bare copper wires (following EN 60228). Core identification According to bus specification Schedule delivery program Overall shield Bending-resistant braiding made of tinned copper wires. Coverage approx. 55% linear, approx. 80% optical. Outer jacket Low-adhesion, oil-resistant mixture on the basis of PVC, adapted to suit the requirements in energy chains (following DIN VDE 0281 Part 13). Colour: Red lilac (similar to RAL 4001) Bending radius moved minimum x d fixed minimum 7,5 x d Temperature moved +5 C to +70 C for use in energy chains with > cycles -5 C to +70 C following DIN EN 60811, part 1-4 chapter 8.2 fixed -20 C to +70 C v max. 3 m/s, 2 m/s unsupported/gliding a max. 30 m/s 2 Lead free Clean room CTP EAC * higher number of double strokes possible Following 2011/65/EC (RoHS-II) According to ISO Class 1. Outer jacket material complies with CF , tested by IPA according to standard Certified according to N o C-DE.PB49.V Certified according to N o TC RU C-DE.ME77.B New! Guaranteed lifetime for this series according to the "chainflex guarantee club" conditions Page Double strokes* 5 million 7,5 million 10 million Temperature, v max. [m/s] a max. Travel distance R min. R min. R min. from/to [ C] unsupported gliding [m/s 2 ] [m] [factor x d] [factor x d] [factor x d] -5 / / Typical application area for medium load requirements light oil influence preferably indoor applications, but also outdoor ones at temperatures > 5 C freely suspended travel distances and up to 20 m for gliding applications Bus connection cable for storage and retrieval units for high-bay warehouses, machining units/machine tools, handling, indoor cranes Travel distance UV-resistant Nominal voltage Testing voltage Freely suspended travel distances and up to 20 m for gliding applications, Class 2 Medium 50 V 500 V Oil Oil-resistant (following DIN EN ), Class 2. Flame-retardant Silicon-free According to IEC , CEI 20-35, FT1, VW-1 Free from silicon which can affect paint adhesion (following PV status 1992). (for up to 10 cuts of the same type) igus GmbH Cologne Tel. +49(0)2203/ Fax -222 info@igus.de 1
6 CFBUS.PVC PVC x d PVC Bus cable CFBUS.PVC Class (4 medium load requirements 2 travel distance up to 20 m 2 oil-resistant) CFBUS.PVC PVC x d CFBUS.PVC.001 CFBUS.PVC.021 CFBUS.PVC.022 (2) Ethernet/CAT5/GigE CFBUS.PVC.040 (2) CFBUS.PVC.045 Number of cores and conductor nominal cross section [mm 2 ] External diameter max. [mm] Copper index Weight (2x0,25)C 8, (2x0,5)C 8, (4x0,5)C 8, (4x0,25)C 6, (4x(2x0,))C 7, CFBUS.PVC.001 CFBUS.PVC.021 CFBUS.PVC.022 (2) Ethernet/CAT5/GigE CFBUS.PVC.040 (2) CFBUS.PVC.045 Characteris tic wave impedance approx. [Ω] 0 Core group (2x0,25)C (2x0,5)C (4x0,5)C (4x0,25)C (4x(2x0,))C Colour code red, green white, brown white-blue/blue, white-orange/orange, white-green/green, white-brown/brown Ethernet/CAT6 A CFBUS.PVC.050 FireWire IEEE 1394b CFBUS.PVC.056 Profinet CFBUS.PVC.060 (2/) USB 3.0 CFBUS.PVC.068 4x(2x0,20)C 9, (2x(2x0,)C+2x0,38)C 9, (4x0,38)C 7, (2x(2xAWG28)+2x(2xAWG28)C)C 7, Ethernet/CAT6 A CFBUS.PVC.050 FireWire IEEE 1394b CFBUS.PVC.056 Profinet CFBUS.PVC.060 (2/) USB 3.0 CFBUS.PVC x(2x0,20)C (2x(2x0,)C 2x0,38 (4x0,38)C 2x(2xAWG28) 2x(2xAWG28)C white/blue, white/orange, white/green, white/brown orange/blue, blue/red black, white white, orange, blue, yellow (star-quad stranding) red/black, green/white-green blue/yellow, red/fioletowy The chainflex types marked with (2) are cables designed as a star-quad. () Colour outer jacket: Yellow green (similar to RAL 6018) Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core Order example: CFBUS.PVC.001 in your desired length (0,5 m steps) CFBUS.PVC chainflex series.001 Code BUS-type prices price list online delivery despatched in time 24 hours or today 2 (for up to 10 cuts of the same type) igus GmbH Cologne Tel. +49(0)2203/ Fax -222 info@igus.de 3
7 CFBUS.PUR PUR x d PUR Bus cable CFBUS.PUR Class (4 medium load requirements 2 travel distance up to 20 m 3 oil-resistant) CFBUS.PUR PUR x d for medium load requirements PUR outer jacket shielded oil-resistant and coolant-resistant notch-resistant PVC-free/halogen-free flame-retardant hydrolysis-resistant and microbe-resistant Conductor Core insulation Core stranding Stranded conductor in especially bending-resistant version consisting of bare copper wires (following EN 60228). Core identification According to bus specification Schedule delivery program Overall shield Bending-resistant braiding made of tinned copper wires. Coverage approx. 55% linear, approx. 80% optical. Outer jacket Low-adhesion, highly abrasion-resistant mixture on the basis of PUR, adapted to suit the requirements in energy chains (following DIN VDE 0282 Part 10). Colour: Red lilac (similar to RAL 4001) Bending radius moved minimum x d fixed minimum 7,5 x d Temperature moved -20 C to +70 C fixed -40 C to +70 C v max. 3 m/s, 2 m/s unsupported/gliding a max. 30 m/s 2 Travel distance UV-resistant Nominal voltage Freely suspended travel distances and up to 20 m for gliding applications, Class 2 Medium 50 V UL/CSA Style 98 and 20236, 30 V, 80 C NFPA Following NFPA chapter 12.9 CEI Following CEI CE DESINA Lead free Clean room CTP EAC Following 2006/95/EG According to VDW, DESINA standardisation Following 2011/65/EC (RoHS-II) According to ISO Class 1. Outer jacket material complies with CF77.UL D, tested by IPA according to standard Certified according to N o C-DE.PB49.V Certified according to N o TC RU C-DE.ME77.B New! Guaranteed lifetime for this series according to the "chainflex guarantee club" conditions Page Double strokes* 5 million 7,5 million 10 million Temperature, v max. [m/s] a max. Travel distance R min. R min. R min. from/to [ C] unsupported gliding [m/s 2 ] [m] [factor x d] [factor x d] [factor x d] -20 / / * higher number of double strokes possible Typical application area for medium load requirements almost unlimited resistance to oil indoor and outdoor applications without direct sun radiation freely suspended travel distances and up to 20 m for gliding applications Bus connection cable for machining units/machine tools, low-temperature applications Testing voltage 500 V Oil Oil-resistant (following DIN EN ), Class 3. Offshore MUD-resistant following NEK 606 status Flame-retardant According to IEC , CEI 20-35, FT1, VW-1 Silicon-free Free from silicon which can affect paint adhesion (following PV status 1992). Halogen-free Following EN (for up to 10 cuts of the same type) igus GmbH Cologne Tel. +49(0)2203/ Fax -222 info@igus.de 5
8 CFBUS.PUR PUR x d PUR Bus cable CFBUS.PUR Class (4 medium load requirements 2 travel distance up to 20 m 3 oil-resistant) CFBUS.PUR PUR x d CFBUS.PUR.001 CFBUS.PUR.021 CFBUS.PUR.022 (2) Ethernet/CAT5/GigE CFBUS.PUR.040 (2) CFBUS.PUR.045 Number of cores and conductor nominal cross section [mm 2 ] External diameter max. [mm] Copper index Weight (2x0,25)C 8, (2x0,5)C 8, (4x0,5)C 8, (4x0,25)C 6, (4x(2x0,))C 7, CFBUS.PUR.001 CFBUS.PUR.021 CFBUS.PUR.022 (2) Ethernet/CAT5/GigE CFBUS.PUR.040 (2) CFBUS.PUR.045 Characteris tic wave impedance approx. [Ω] 0 Core group (2x0,25)C (2x0,5)C (4x0,5)C (4x0,25)C (4x(2x0,))C Colour code red, green white, brown white-blue/blue, white-orange/orange, white-green/green, white-brown/brown Ethernet/CAT6 A CFBUS.PUR.050 4x(2x0,20)C 9, Ethernet/CAT6 A CFBUS.PUR.050 4x(2x0,20)C white/blue, white/orange, white/green, white/brown FireWire IEEE 1394b CFBUS.PUR.056 Profinet CFBUS.PUR.060 (2/) USB 3.0 CFBUS.PUR.068 (2x(2x0,)C+2x0,38)C 9, (4x0,38)C 7, (2x(2xAWG28)+2x(2xAWG28)C)C 7, FireWire IEEE 1394b CFBUS.PUR.056 Profinet CFBUS.PUR.060 (2/) USB 3.0 CFBUS.PUR (2x(2x0,)C 2x0,38 (4x0,38)C 2x(2xAWG28) 2x(2xAWG28)C orange/blue, blue/red black, white white, orange, blue, yellow (star-quad stranding) red/black, green/white-green blue/yellow, red/fioletowy The chainflex types marked with (2) are cables designed as a star-quad. () Colour outer jacket: Yellow green (similar to RAL 6018) Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core Order example: CFBUS.PUR.001 in your desired length (0,5 m steps) CFBUS.PUR chainflex series.001 Code BUS-type prices price list online delivery despatched in time 24 hours or today 6 (for up to 10 cuts of the same type) igus GmbH Cologne Tel. +49(0)2203/ Fax -222 info@igus.de 7
9 CFBUS 10- x d Bus cable CFBUS Class (6 maximum load requirements 5 travel distance up to 400 m 4 oil-resistant) CFBUS 10- x d for maximum load requirements outer jacket shielded oil-resistant biooil-resistant flame-retardant hydrolysis-resistant and microbe-resistant UL/CSA Schedule delivery program NFPA Following NFPA chapter 12.9 CEI Following CEI CE Following 2006/95/EG Conductor Core insulation Core stranding Stranded conductor in especially bending-resistant version consisting of bare copper wires (following EN 60228). Core identification According to bus specification Schedule delivery program Inner jacket mixture adapted to suit the requirements in energy chains. DESINA Lead free Clean room CTP EAC According to VDW, DESINA standardisation Following 2011/65/EC (RoHS-II) According to ISO Class 1. Outer jacket material complies with CF34.UL D, tested by IPA according to standard Certified according to N o C-DE.PB49.V Certified according to N o TC RU C-DE.ME77.B Overall shield Extremely bending-resistant braiding made of tinned copper wires. Coverage approx. 70% linear, approx. 90% optical. Outer jacket Low-adhesion mixture on the basis of, especially abrasionresistant and highly flexible, adapted to suit the requirements in energy chains. Colour: Red lilac (similar to RAL 4001) Bending radius moved minimum 10- x d fixed minimum 5 x d Temperature moved -35 C to +70 C fixed -40 C to +70 C v max. 10 m/s, 6 m/s unsupported/gliding a max. m/s 2 New! Guaranteed lifetime for this series according to the "chainflex guarantee club" conditions Page Double strokes* 5 million 7,5 million 10 million Temperature, v max. [m/s] a max. Travel distance R min. R min. R min. from/to [ C] unsupported gliding [m/s 2 ] [m] [factor x d] [factor x d] [factor x d] Art.-Nr. CFBUS / Art.-Nr. CFBUS / * higher number of double strokes possible Travel distance UV-resistant Nominal voltage Testing voltage Freely suspended travel distances and up to 400 m for gliding applications, Class 5 Medium 50 V 500 V Typical application area for maximum load requirements almost unlimited resistance to oil, also with bio-oils indoor and outdoor applications without direct sun radiation freely suspended travel distances and up to 400 m for gliding applications Bus connection cable for storage and retrieval units for high-bay warehouses, machining units/machine tools, quick handling, clean room, semiconductor insertion, indoor cranes, low-temperature applications Oil Flame-retardant Oil-resistant (following DIN EN ), biooil-resistant (following VDMA with Plantocut 8 S-MB tested by DEA), Class 4. According to IEC , CEI 20-35, FT1, VW-1 Silicon-free Free from silicon which can affect paint adhesion (following PV status 1992). (for up to 10 cuts of the same type) Test data Page 40 or igus GmbH Cologne Tel. +49(0)2203/ Fax -222 info@igus.de 9
10 CFBUS 10- x d Bus cable CFBUS Class (6 maximum load requirements 5 travel distance up to 400 m 4 oil-resistant) CFBUS 10- x d Number of cores and External conductor nominal cross diameter section [mm 2 ] max. [mm] (minimum bending radius 10 x d) Style 89/21371, 30 V, 80 C CFBUS.001 CFBUS.002 CFBUS.003 Interbus (minimum bending radius 10 x d) Style 89/21371, 30 V, 80 C CFBUS.010 CFBUS.011 Copper index Weight (2x0,25)C 8, (2x0,25)C+4x1, (2x0,25)C+3G0,75 11, (3x(2x0,25))C 9, (3x(2x0,25)+(3G1,0))C 10, CAN-BUS/Fieldbus (minimum bending radius 10 x d) Style 89/21371, 30 V, 80 C CFBUS.020 (2) (4x0,25)C 6, CFBUS.021 (2x0,5)C 8, CFBUS.022 (2) (4x0,5)C 8, DeviceNet (minimum bending radius 10 x d) Style 89/21371, 30 V, 80 C CFBUS.030 (4) Drop ((2xAWG24)C+2xAWG22)C 7, CFBUS.031 CC-Link (minimum bending radius 10 x d) Style 89/21371, 30 V, 80 C CFBUS.035 (3xAWG20)C 8, Ethernet/CAT5/GigE (minimum bending radius 10 x d) Style 10138/21235, 300 V, 80 C starting from manufacturing date 4/2012 CFBUS.040 (2) CFBUS.041 CFBUS.044 CFBUS.045 Trunk ((2xAWG18)C+2xAWG)C 11, (4x0,25)C 7, (4x(2x0,25))C 10, (4x(2x0,))C 8, (4x(2x0,))C 8, Ethernet/CAT6 A (minimum bending radius x d) Style 89/21371, 30 V, 80 C CFBUS.050 (4x(2x0,)C)C 10, CFBUS.001 CFBUS.002 CFBUS.003 Interbus CFBUS.010 CFBUS.011 CAN-BUS/Feldbus CFBUS.020 (2) CFBUS.021 CFBUS.022 (2) DeviceNet CFBUS.030 (4) Drop CFBUS.031 CC-Link CFBUS.035 Ethernet/CAT5/GigE CFBUS.040 (2) CFBUS.041 CFBUS.044 CFBUS.045 Ethernet/CAT6 A CFBUS.050 Trunk Characteris tic wave impedance approx. [Ω] Core group (2x0,25)C (2x0,25)C 4x1,5 (2x0,25)C 3G0,75 3x(2x0,25) 3x(2x0,25) 3G1,0 (4x0,25)C (2x0,5)C (4x0,5)C (2xAWG24)C 2xAWG22 (2xAWG18)C 2xAWG (3xAWG20)C (4x0,25)C (4x(2x0,25))C (4x(2x0,))C (4x(2x0,))C (4x(2x0,)C)C Colour code red, green red/green black with white numbers 1-4 red/green black, blue, green-yellow white/brown, green/yellow, grey/pink white/brown, green/yellow, grey/pink red, blue, green-yellow white, brown white/ blue red, black white/ blue red, black white, blue, yellow white/brown, green/yellow, grey/pink, blue/red white/brown, green/yellow, grey/pink, blue/red white-blue/blue, white-orange/orange, white-green/green, white-brown/brown white/blue, white/orange, white/green, white/brown (4) manufactured without inner jacket The chainflex types marked with (2) are cables designed as a star-quad. Other types available on request. Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core Other types Page 2 Technical note The USB, FireWire and GigE-cables shown on these pages were developed for the ambitious industrial usage in e-chains. High proofness to oil and lubricants is as secured as protection against electromagnetical interferences. This high mechanical service life was reached with the usage of high quality materials which even care for the electrical safeness. In single cases communication errors can occur, if very different hardware and software is combined. We recommend tests with all components and the cables before starting serial production, to get the proove for a perfect running system. Of course we support you with the details of these electrical tests. Just give us a call! 0 (for up to 10 cuts of the same type) igus GmbH Cologne Tel. +49(0)2203/ Fax -222 info@igus.de 1
11 CFBUS 10- x d Bus cable CFBUS Class (6 maximum load requirements 5 travel distance up to 400 m 4 oil-resistant) CFBUS 10- x d Number of cores and External Copper Weight conductor nominal cross diameter index section [mm 2 ] max. [mm] FireWire IEEE 1394a (minimum bending radius x d) Style 89/21371, 30 V, 80 C CFBUS.055 2x(2x0,)C+2x(0,34)C 8, Profinet (minimum bending radius x d) Style 10138/21235, 300 V, 80 C starting from manufacturing date 4/2012 CFBUS.060 (2/) (4x0,38)C 7, USB (minimum bending radius x d) Style 89/21371, 30 V, 80 C CFBUS.065 ((2xAWG28)+2xAWG20)C 5, CFBUS.066 ((2xAWG24)+2xAWG20)C 6, DVI (minimum bending radius x d) Style 89/21371, 30 V, 80 C CFBUS.070 (4x(2xAWG28)C+(2xAWG28)+3xAWG28)C 9, approx. [Ω] FireWire IEEE 1394b CFBUS.055 Profinet CFBUS.060 (2/) USB CFBUS.065 CFBUS.066 DVI CFBUS.070 Characteris tic wave impedance Core group 2x(2x0,)C 2x(0,34)C (4x0,38)C (2xAWG28) 2xAWG20 (2xAWG24) 2xAWG20 4x(2xAWG28)C (2xAWG28) 3xAWG28 Colour code orange/blue, green/red white, black white, orange, blue, yellow (star-quad stranding) white/green red, black white/green red, black 4 x white/yellow with element jacket in blue, black, white, red white/brown green, yellow, grey The chainflex types marked with (2) are cables designed as a star-quad. () Colour outer jacket: Yellow green (similar to RAL 6018) Other types available on request. Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core Order example: CFBUS.060 in your desired length (0,5 m steps) CFBUS chainflex series.060 Code BUS-type Other types Page 0 prices price list online delivery despatched in time 24 hours or today Technical note The USB, FireWire and GigE-cables shown on these pages were developed for the ambitious industrial usage in e-chains. High proofness to oil and lubricants is as secured as protection against electromagnetical interferences. This high mechanical service life was reached with the usage of high quality materials which even care for the electrical safeness. In single cases communication errors can occur, if very different hardware and software is combined. We recommend tests with all components and the cables before starting serial production, to get the proove for a perfect running system. Of course we support you with the details of these electrical tests. Just give us a call! 2 (for up to 10 cuts of the same type) igus GmbH Cologne Tel. +49(0)2203/ Fax -222 info@igus.de 3
12 CF11.LC 10 x d Bus cable CF11.LC (low capacitance) Class (6 maximum load requirements 5 travel distance up to 400 m 4 oil-resistant) CF11.LC 10 x d for maximum load requirements outer jacket shielded oil-resistant biooil-resistant PVC-free/halogen-free UV-resistant hydrolysis-resistant and microbe-resistant Conductor Core insulation Core stranding Stranded conductor in especially bending-resistant version consisting of bare copper wires (following EN 60228). Core identification According to bus specification Schedule delivery program Inner jacket mixture adapted to suit the requirements in energy chains. Overall shield Extremely bending-resistant braiding made of tinned copper wires. Coverage approx. 70% linear, approx. 90% optical. Outer jacket Low-adhesion mixture on the basis of, especially abrasionresistant and highly flexible, adapted to suit the requirements in energy chains. Colour: Steel blue (similar to RAL 5011) Bending radius moved minimum 10 x d fixed minimum 5 x d Temperature moved -35 C to +70 C fixed -40 C to +70 C v max. 10 m/s, 6 m/s unsupported/gliding a max. m/s 2 Halogen-free Following EN CE Lead free Clean room EAC Following 2006/95/EG Following 2011/65/EC (RoHS-II) According to ISO Class 1. Outer jacket material complies with CF9..07, tested by IPA according to standard Certified according to N o TC RU C-DE.ME77.B New! Guaranteed lifetime for this series according to the "chainflex guarantee club" conditions Page Double strokes* 5 million 7,5 million 10 million Temperature, v max. [m/s] a max. Travel distance R min. R min. R min. from/to [ C] unsupported gliding [m/s 2 ] [m] [factor x d] [factor x d] [factor x d] -25 / * higher number of double strokes possible 400 Typical application area for maximum load requirements almost unlimited resistance to oil, also with bio-oils Indoor and outdoor applications, UV-resistant freely suspended travel distances and up to 400 m for gliding applications Bus connection cable for storage and retrieval units for high-bay warehouses, machining units/machine tools, quick handling, clean room, semiconductor insertion, outdoor cranes, low-temperature applications Travel distance UV-resistant Nominal voltage Testing voltage Oil Silicon-free Freely suspended travel distances and up to 400 m for gliding applications, Class 5 High 50 V 500 V Oil-resistant (following DIN EN ), biooil-resistant (following VDMA with Plantocut 8 S-MB tested by DEA), Class 4. Free from silicon which can affect paint adhesion (following PV status 1992). (for up to 10 cuts of the same type) igus GmbH Cologne Tel. +49(0)2203/ Fax -222 info@igus.de 5
13 CF11.LC 10 x d Bus cable CF11.LC (low capacitance) Class (6 maximum load requirements 5 travel distance up to 400 m 4 oil-resistant) CF11.LC 10 x d CF PBA.LC (2) Interbus CF IB-S CF IB-S CF LC CF LC (2) Number of cores and conductor nominal cross section [mm 2 ] External diameter max. [mm] The chainflex types marked with (2) are cables designed as a star-quad. Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core Copper index Weight (4x0,25)C 8, (3x(2x0,25))C 9, (3x(2x0,25)+(3G1,0))C 10, (2x0,5)C 8, (4x0,5)C 8, CF PBA.LC Interbus CF IB-S CF IB-S CF LC CF LC Characteris tic wave impedance approx. [Ω] 0 Order example: CF IB-S in your desired length (0,5 m steps) CF11.LC chainflex series.02 Code nominal cross section.03 Number of pairs.02 Identification pairs.ib-s Special identification prices price list online delivery despatched in time 24 hours or today Core group (4x0,25)C (3x(2x0,25))C 3x(2x0,25) 3G1,0 (2x0,5)C (4x0,5)C Colour code green, yellow, red, brown (star-quad stranding) white/brown, green/yellow, grey/pink white/brown, green/yellow, grey/pink red, blue, green-yellow white, brown 6 (for up to 10 cuts of the same type) igus GmbH Cologne Tel. +49(0)2203/ Fax -222 info@igus.de 7
14 CF11.LC.D 10 x d Bus cable CF11.LC.D (low capacitance) Class (6 maximum load requirements 5 travel distance up to 400 m 4 oil-resistant) CF11.LC.D 10 x d for maximum load requirements outer jacket shielded PVC-free/halogen-free oil-resistant biooil-resistant hydrolysis-resistant and microbe-resistant Halogen-free Following EN CE Following 2006/95/EG DESINA According to VDW, DESINA standardisation Lead free Following 2011/65/EC (RoHS-II) Conductor Core insulation Stranded conductor in especially bending-resistant version consisting of bare copper wires (following EN 60228). Clean room EAC According to ISO Class 1. Outer jacket material complies with CF9..07, tested by IPA according to standard Certified according to N o TC RU C-DE.ME77.B Core stranding Core identification According to bus specification Schedule delivery program Inner jacket mixture adapted to suit the requirements in energy chains. Overall shield Extremely bending-resistant braiding made of tinned copper wires. Coverage approx. 70% linear, approx. 90% optical. Outer jacket Low-adhesion mixture on the basis of, especially abrasionresistant and highly flexible, adapted to suit the requirements in energy chains. Colour: Red lilac (similar to RAL 4001) Bending radius moved minimum 10 x d fixed minimum 5 x d Temperature moved -35 C to +70 C fixed -40 C to +70 C v max. 10 m/s, 6 m/s unsupported/gliding a max. m/s 2 New! Guaranteed lifetime for this series according to the "chainflex guarantee club" conditions Page Double strokes* 5 million 7,5 million 10 million Temperature, v max. [m/s] a max. Travel distance R min. R min. R min. from/to [ C] unsupported gliding [m/s 2 ] [m] [factor x d] [factor x d] [factor x d] -25 / * higher number of double strokes possible 400 Typical application area for maximum load requirements almost unlimited resistance to oil, also with bio-oils indoor and outdoor applications without direct sun radiation freely suspended travel distances and up to 400 m for gliding applications Bus connection cable for storage and retrieval units for high-bay warehouses, machining units/machine tools, quick handling, clean room, semiconductor insertion, indoor cranes, low-temperature applications Travel distance UV-resistant Nominal voltage Testing voltage Oil Silicon-free Freely suspended travel distances and up to 400 m for gliding applications, Class 5 Medium 50 V 500 V Oil-resistant (following DIN EN ), biooil-resistant (following VDMA with Plantocut 8 S-MB tested by DEA), Class 4. Free from silicon which can affect paint adhesion (following PV status 1992). (for up to 10 cuts of the same type) igus GmbH Cologne Tel. +49(0)2203/ Fax -222 info@igus.de 9
15 CF11.LC.D 10 x d Bus cable CF11.LC.D (low capacitance) Class (6 maximum load requirements 5 travel distance up to 400 m 4 oil-resistant) CF11.LC.D 10 x d CF PBA.LC.D CF PBA.LC.D CF PBA.LC.D CF LC.D (2) CF LC.D Number of cores and conductor nominal cross section [mm 2 ] The chainflex types marked with (2) are cables designed as a star-quad. Other types available on request. Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core External diameter max. [mm] Copper index Weight (2x0,25)C 8, (2x0,25)C+3G0,75 11, (2x0,25)C+4x1, (4x0,25)C 6, (2x0,5)C 8, CF PBA.LC.D CF PBA.LC.D CF PBA.LC.D CF LC.D CF LC.D Characteris tic wave impedance approx. [Ω] Order example: CF PBA.LC.D in your desired length (0,5 m steps) CF11.LC.D chainflex series.02 Code nominal cross section.01 Number of pairs.02 Identification pairs.pba.lc.d Special identification prices price list online delivery despatched in time 24 hours or today Core group (2x0,25)C (2x0,25)C 3G0,75 (2x0,25)C 4x1,5 (4x0,25)C (2x0,5)C Colour code red, green red/green black with white numbers 1-4 red/green black, blue, green-yellow white, brown (for up to 10 cuts of the same type) igus GmbH Cologne Tel. +49(0)2203/ Fax -222 info@igus.de 181
16 CF14 CAT5 x d Bus cable CF14CAT5 Class (6 maximum load requirements 5 travel distance up to 400 m 4 oil-resistant) CF14 CAT5 x d Ethernet special cable for heavy-duty use outer jacket oil-resistant biooil-resistant PVC-free/halogen-free UV-resistant hydrolysis-resistant and microbe-resistant Conductor Core insulation 19-wire conductor consisting of bare copper wires in especially bending-resistant braiding quality. Special PP-isolating mixture. Core stranding 2 cores each stranded in pairs with short pitch lengths, core pairs also stranded with short pitch lengths. Core identification Colour code in accordance with DIN 47 Inner jacket mixture adapted to suit the requirements in energy chains. Overall shield Extremely bending-resistant braiding made of tinned copper wires. Coverage approx. 70% linear, approx. 90% optical. Outer jacket Low-adhesion mixture on the basis of, especially abrasionresistant and highly flexible, adapted to suit the requirements in energy chains. Colour: Red lilac (similar to RAL 4001) Bending radius moved minimum 10 x d fixed minimum 5 x d Temperature moved -35 C to +70 C fixed -40 C to +70 C v max. 10 m/s, 6 m/s unsupported/gliding a max. m/s 2 Travel distance UV-resistant Freely suspended travel distances and up to 400 m for gliding applications, Class 5 Medium CE DESINA Lead free Clean room EAC Following 2006/95/EG According to VDW, DESINA standardisation Following 2011/65/EC (RoHS-II) According to ISO Class 1. Outer jacket material complies with CF9..07, tested by IPA according to standard Certified according to N o TC RU C-DE.ME77.B New! Guaranteed lifetime for this series according to the "chainflex guarantee club" conditions Page Double strokes* 5 million 7,5 million 10 million Temperature, v max. [m/s] a max. Travel distance R min. R min. R min. from/to [ C] unsupported gliding [m/s 2 ] [m] [factor x d] [factor x d] [factor x d] -25 / +60 Typical application area for maximum load requirements almost unlimited resistance to oil, also with bio-oils indoor and outdoor applications without direct sun radiation freely suspended travel distances and up to 400 m for gliding applications Ethernet cable for Storage and retrieval units for high-bay warehouses, machining units/machine tools, quick handling, clean room, semiconductor insertion, indoor cranes, low-temperature applications Ethernet/CAT5/GigE CF CAT5 CF CAT5 (2) CF CAT5 CF CAT * higher number of double strokes possible Number of cores and conductor nominal cross section [mm 2 ] 400 External diameter max. [mm] 10 Copper index 11 Weight (4x(2x0,))C 8, (4x0,25)C 7, (4x(2x0,25))C 10, (5x(2x0,25))C 10, Nominal voltage 50 V The chainflex types marked with (2) are cables designed as a star-quad. Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core Testing voltage 500 V Oil Oil-resistant (following DIN EN ), biooil-resistant (following VDMA with Plantocut 8 S-MB tested by DEA), Class 4. Silicon-free Free from silicon which can affect paint adhesion (following PV status 1992). Halogen-free Following EN Ethernet/CAT5/GigE CF CAT5 CF CAT5 (2) CF CAT5 CF CAT5 Characteris tic wave impedance approx. [Ω] Cores group (4x(2x0,))C (4x0,25)C (4x(2x0,25))C (5x(2x0,25))C Colour code white/brown, green/yellow, grey/pink, blue/red white/brown, green/yellow, gre y/pink, blue/red, black/fioletowy white/brown, green/yellow, grey/pink, blue/red, black/fioletowy (for up to 10 cuts of the same type) Test data Page 38 or More CAT5/CAT6 cables Page 0, CFBUS igus GmbH Cologne Tel. +49(0)2203/ Fax -222 info@igus.de 183
chainflex cables with DNV-GL certification ndustry plastics for longer life
ffshore chainflex cables with DNV-GL certification ndustry plastics for longer life...... www.igus.eu/offshore... 348 chainflex cables...... with GL-DNV approval chainflex cables Jacket material Shielded
More informationchainflex cables with GERMANISCHER LLOYD certification ndustry plastics for longer life
ffshore chainflex cables with GERMANISCHER LLOYD certification ndustry plastics for longer life...... www.igus.eu/offshore... 348 chainflex cables with Germanischer Lloyd approval chainflex cables Jacket
More informationCF11.LC / CF11.LC.D CF14.CAT5
TPE - e-chain - Bus cable for maximum load requirements (Class 6.6.4): shielded, oil- and biooil-resistant, PVC- and halogen-free as well as hydrolysis- and microbe-resistant. Overview Example drawing
More informationChainflex cable. Bus cables. Exclusive! Chainflex guarantee guaranteed lifetime Selection table page 174. Information Chainflex Ethernet cables
types cable Jacket Shield Bend radius min., E-Chain [factor x d] Temperature, E-Chain from/to [ F] Approvals and standards oil-resistant torsion resistant v max. [ft/s] unsupported v max. [ft/s] gliding
More informationCables up to CAT7.
thernet Cables up to CAT7 www.igus.eu/ethernet Cost down...... Service life up For all data volumes and types of movement... ing your machine with cables. The cheapest cable that is guaranteed to work.
More informationData sheet CFBUS.PVC PVC - e-chain - Bus cable for medium load requirements (class 4.3.2): shielded, oil-resistant as well as flame-retardant.
Overview Bus system Profibus CAN-Bus / Feldbus CC-Link Part. No..001.021 &.022.035 Example drawing Bus system Part. No. Ethernet (CAT5 / CAT5e / GigE / PoE).040,.045 &.049 Ethernet (CAT6 A / PoE).050 FireWire
More informationCables up to CAT7.
thernet Cables up to CAT7 www.igus.eu/ethernet Cost down...... Service life up For all data volumes and types of movement... Networking your machine with cables. The cheapest cable that is guaranteed to
More informationCFBUS CFBUS.PVC.040 CFBUS.PUR.040 CFBUS.040 CF CAT5 CFBUS.041 CFBUS.044
for medium to high load requirements. Overview Class.PVC.PUR (3D-e-chain - cable) CAT5 (4x0,25)C (4x(2x0,25))C.PVC.040.PUR.040.040 CF14.02.02.02.CAT5 34 mm.041 CF14.02.04.02.CAT5 (5x(2x0,25))C 34 mm igus
More informationCAN-Bus cable. CAN-Bus cable Can-Bus / Field-Bus cable for medium to maximum load requirements. chainflex cable. Overview. igus e-chainsystems
Overview Stranding.PVC.PUR.D (4x0,25)C (2x0,5)C.020 CF11.02.02.02.LC.D igus chainflex +++ chainflex cable works +++ (4x0,5)C.PVC.021.PUR.021.021 CF11.05.01.02.LC CF11.05.01.02.LC.D.PVC.022.PUR.022.022
More informationData sheet chainflex CF270.UL.D
For detailed overview please see design table 1. Outer jacket: Pressure extruded PUR mixture 2. Overall shield: Bending-resistant braiding made of tinned copper wires. 3. Banding: Plastic fleece 4. Core
More informationData sheet chainflex CF113.D
For detailed overview please see design table 1. Outer jacket: Pressure extruded PUR mixture 2. Banding: Plastic fleece 3. Overall shield: Extremely bending-stable braid made of tinned copper wires 4.
More informationCF270.UL.D.
Outer jacket: Pressure extruded PUR mixture Overall shield: Bending-stable braid made of tinned copper wires Core insulation: Mechanically high-quality, especially low-capacitance TPE mixture Conductor:
More informationCables up to CAT7.
thernet Cables up to CAT7 www.igus.eu/ethernet Cost down...... Service life up For all data volumes and types of movement... Networking your machine with Ethernet cables. Always find the right Ethernet
More informationData sheet chainflex CF300.UL.D
1. Outer jacket: Pressure extruded, flame-retardant TPE mixture 2. Core insulation: Mechanically high-quality TPE mixture 3. Conductor: Conductor rope in especially bending-stable version consisting of
More informationData sheet chainflex CF310.UL
1. Outer jacket: Pressure extruded, flame-retardant TPE mixture 2. Overall shield: Aluminum/Polyester tape and extremely bending-resistant braiding made of tinned copper wires. 3. Core insulation: Mechanically
More information14 HH EAC/CTP CE RoHS-II conform
Outer jacket: Pressure extruded PUR mixture Inner jacket: Pressure extruded, gusset filling PUR mixture 12 cores or more: Bundles with optimized pitch length and pitch direction Conductor: Fine-wire strand
More informationData sheet chainflex CF340
1. Outer jacket: Pressure extruded, halogen-free TPE mixture 2. Overall shield: Aluminum/Polyester tape and extremely bending-resistant braiding made of tinned copper wires. 3. Core insulation: Mechanically
More informationData sheet chainflex CF10
1. Outer jacket: Pressure extruded, halogen-free TPE mixture 2. Overall shield: Extremely bending-resistant braiding made of tinned copper wires 3. Inner jacket: Pressure extruded, gusset-filling TPE mixture
More informationData sheet chainflex CF330.D
1. Outer jacket: Pressure extruded, halogen-free TPE mixture 2. Core insulation: Mechanically high-quality TPE mixture 3. Conductor: Conductor rope in especially bending-stable version consisting of bare
More informationData sheet chainflex CF6
1. Outer jacket: Pressure extruded, oil-resistant PVC mixture 2. Overall shield: Extremely bending-stable braid made of tinned copper wires 3. Inner jacket: Pressure extruded, gusset-filling PVC mixture
More informationBus system Profibus Ethernet (CAT 5e / GigE / PoE) ASinterface Part. No. CF CF CF & CF mm
Overview Bus system Profibus Ethernet (CAT 5e / GigE / PoE) ASinterface Part. No. CF898.001 CF898.045 CF898.080 & CF898.081 Example drawing 34 mm Core design: Conductor: Core insulation: Core identification:
More informationSpecial cables. Guarantee. Special cables
Special cables chainflex cable Special cables CFTHERMO Thermocouple cable 384 CFFLAT Single core flat cable 386 CFBRAID Braided conductors 388 CFSPECIAL.182 Cables for hanging applications 390 CFSPECIAL.414
More informationArt.-Nr. CF280.UL.H1xx.XX.XX.D CF280.UL.H2xx.XX.XX.D
Overview Construction (similar to) SICK (Hiperface DSL) SEW Art.-Nr. CF280.UL.H1xx.XX.XX.D CF280.UL.H2xx.XX.XX.D 1 2 3 Example drawing L1 L2 L3 (see the chapter belonging to the cable for details) (see
More informationData sheet chainflex CF240
1. Outer jacket: Pressure extruded, oil-resistant PVC mixture 2. Overall shield: Aluminum/Polyester tape and extremely bending-resistant braiding made of tinned copper wires. 3. Banding: Plastic foil 4.
More informationData sheet chainflex CF210.UL
For detailed overview please see design table 1. Outer jacket: Pressure extruded, oil-resistant PVC mixture 2. Overall shield: Bending-resistant braiding made of tinned copper wires. 3. Banding: Plastic
More informationData sheet chainflex CF886
1. Outer jacket: Pressure extruded PVC mixture 2. Overall shield: Braiding made of tinned copper wires 3. Banding: Plastic foil 4. Core insulation: Mechanically high-quality PVC mixture 5. Conductor: Conductor
More informationCFRIP - tear strip for faster stripping
Outer jacket: Pressure extruded, gusset filling, flame-retardant TPE mixture 12 cores or more: Bundles with optimized pitch length and pitch direction Conductor: Fine-wire strand in especially bendingstable
More informationData sheet chainflex CF9
1. Outer jacket: Pressure extruded, gusset-filling, halogenfree TPE mixture 2. CFRIP: Tear strip for faster cable stripping 3. Core insulation: Mechanically high-quality TPE mixture 4. Conductor: Stranded
More informationData sheet chainflex CF140.UL
1. Outer jacket: Pressure extruded PVC mixture 2. Overall shield: Bending-resistant braiding made of tinned copper wires 3. Inner jacket: Pressure extruded, gusset-filling PVC mixture 4. CFRIP: Tear strip
More informationData sheet chainflex CF881
1. Outer jacket: Pressure extruded PVC mixture 2. Overall shield: Braiding made of tinned copper wires 3. Banding: Plastic foil 4. Core insulation: Mechanically high-quality PVC mixture 5. Conductor: Stranded
More informationConductor: Fine-wire strand consisting of bare copper wires (following DIN EN 60228). Mechanically high-quality TPE mixture. (see colour code table)
Outer jacket: Pressure extruded PVC mixture Inner jacket: Pressure extruded, gusset filling PVC mixture Conductor: Fine-wire strand consisting of bare copper wires 6 1 Core insulation: Mechanically highquality
More informationGuarantee. Special cables
Special cables Chainflex cable Approvals and standards Page Special cables CFTHERMO Thermocouple cable 400 CFFLAT Single core flat cable 402 CFBRAID Braided conductors 404 CFSPECIAL-182 Cables for hanging
More informationchainflex cable Servo cables Exclusive! chainflex guarantee guaranteed lifetime Selection table page 268 CF887 PVC 15 +5/
chainflex types Servo cables chainflex cable Servo cables Jacket Shield Bend radius min., e-chain [factor x d] Temperature, e-chain from/to [ C] Approvals and standards Exclusive! chainflex guarantee guaranteed
More informationData sheet chainflex CF5
1. Outer jacket: Pressure extruded, gusset-filling, oilresistant PVC mixture 2. Core insulation: Mechanically high-quality TPE or PVC mixture 3. CFRIP: Tear strip for faster cable stripping 4. Conductor:
More informationData sheet chainflex CF886
1. Outer jacket: Pressure extruded PVC mixture 2. Overall shield: Braiding made of tinned copper wires 3. Shield foil: Aluminium clad plastic foil 4. Banding: Plastic foil 5. Filling: Plastic yarns 6.
More informationData sheet chainflex CF8821
1. Outer jacket: Pressure extruded, oil-resistant PVC mixture 2. Overall shield: Braiding made of tinned copper wires 3. Overall banding: Plastic foil 4. Core insulation: Mechanically high-quality TPE
More informationData sheet chainflex CF885.PE
1. Outer jacket: Pressure extruded PVC mixture 2. Core insulation: Mechanically high-quality PVC mixture 3. Conductor: Conductor consisting of bare copper wires For detailed overview please see design
More informationchainflex cable Servo cables CF887 PVC 15 +5/ CF210.UL PVC 10 +5/ CF220.UL.H PVC 10 +5/
chainflex cable Jacket Shield Bending radius min., e-chain e-chain Approvals and standards Oil-resistant Torsion resistant v max. [m/s], unsupported v max. [m/s] gliding a max. [m/s 2 ] Servo cables Page
More informationConductor: Fine-wire strand consisting of bare copper wires (following DIN EN 60228). Mechanically high-quality TPE mixture. (see colour code table)
Outer jacket: Pressure extruded, gusset filling PVC mixture 12 cores or more: Bundles with optimized pitch length and pitch direction Conductor: Fine-wire strand consisting of bare copper wires Core insulation:
More informationData sheet chainflex CFSOFT1
to 5 x d Highly flexible, soft design PVC outer jacket Oil-resistant Flame retardant 1. Outer jacket: Pressure extruded, oil-resistant PVC mixture 2. Core insulation: Mechanically high-quality TPE mixture
More informationData sheet chainflex CF130.UL
1. Outer jacket: Pressure extruded, gusset-filling PVC mixture 2. CFRIP: Tear strip for faster cable stripping 3. Core insulation: Mechanically high-quality TPE mixture 4. Conductor: Fine-wire strand consisting
More informationArt.-Nr. CF220.UL.H1xx.XX.XX CF220.UL.H2xx.XX.XX
Overview Construction (similar to) SICK (Hiperface DSL) SEW Art.-Nr. CF220.UL.H1xx.XX.XX CF220.UL.H2xx.XX.XX 1 2 3 Example drawing L1 L2 L3 (see the chapter belonging to the cable for details) (see the
More informationDNV-GL HH CE RoHS-II conform
Armour: Extremely bending- and torsion-stable aramid braid Armour: Extremely bending- and torsion-stable aramid wrapping Outer jacket: Pressure extruded PUR mixture Fibre: FOC-fibre made out of glass Subcable
More informationchainflex readycable Video-/vision-/bus technology (with camera reference list Page 280) FireWire Ready-made cable TPE 260
Camera Video-/vision-/bus technology chainflex readycable Cable type Jacket Page Video-/vision-/bus technology (with camera reference list Page 280) FireWire Ready-made cable 260 USB Ready-made cable 264
More informationSpecial cables. chainflex Typees. chainflex
chainflex Typees Special cables chainflex cable Special cables CFTHERMO Thermocouple cable 406 CFTHERMO Thermocouple cable - ready-made 408 CFFLAT Single core flat cables 410 CFBRAID Braided cores 412
More informationMin. bending radius for fixed installation 7,5 x d 6,8 x d 4,0 x d 6,8 x d Torsion (at 1 m cable length) --- ±45 ±90 ±45
Outer jacket: Pressure extruded, gusset filling, oil-resistant PVC mixture 12 cores or more: Bundles with optimized pitch length and pitch direction Conductor: Fine-wire strand consisting of bare copper
More informationFibre optic cables. Guarantee. Fibre optic cables. Information about Fibre optic cables CFLK CFLG88 CFLG.LB.PUR CFLG.LB CFLG.G
Page [m/s2] v max. [m/s] gliding v max. [m/s]. unsupported Torsion resistant Oil-resistant Approvals and standards Temperature. e-chain Minimum bend radius. e-chain Jacket chainflex cable Fibre optic cables
More informationchainflex type Fibre optic cables* Information fibre optic cables 154 CFLK** PUR 12,5-20/ CFLG.2H CFLG.LB*** TPE 5-40/
chainflex type ibre optic cables chainflex cable Information fibre optic cables 154 CFLK** PUR 12,5-20/ +70 10 5 20 156 CFLG.2H Jacket Fibre optic cables* Shield Min. bending radius, moved [factor x d]
More informationTechnical data sheet LÜTZE SUPERFLEX PLUS (C) PUR FEEDBACK Encoder cables for Siemens and other systems For highest requirements in drive technology
PUR feedback cables C-track compatible Subject to technical modification 111456 Identification Type SU+(C)P SE(4 0,5+4 2 0,38)UL 30V GN SIEMENS designation* 1BD21 Use/Application/Characteristics Application
More informationTechnical data sheet LÜTZE SUPERFLEX PLUS M (C) PUR SERVO 0.6/1 kv Supply line for Bosch Rexroth and other systems For highest requirements
PVC servo cables C-track compatible shielded Subject to technical modification 111270 Identification Type SU+M(C)P SE(4G1,0+2 (2 0,75))UL 1KV OR INK Description* INK 0653 Use/Application/Properties Application
More informationIdentification Type SU+M(C)P SE(4G1,5+(2 0,75)+(2 AWG22))UL 1KV OR. Part-No
PUR servo cables C-track compatible shielded Subject to technical modification 111600 Identification Type SU+M(C)P SE(4G1,5+(2 0,75)+(2 AWG22))UL 1KV OR Use/Application/Properties Application Combined
More informationData sheet. Connection cable M12 jack straight - free line end 8-pole, X-coded 0.5 m. Illustrations P/N 142M2X20005 EAN
Page 1/6 Illustrations Dimensional drawing Cut-out See enlarged drawings at the end of document Product specification shielded M12 Ethernet connection cable Cat.6A, x-coded, 8-pole side 1: M12-jack, straight
More informationPRODUCT INFORMATION. UNITRONIC LiYCY. Benefits Overall shield minimises electrical interference Versatile application possibilities
Shielded data cable with colour code according to DIN 47100 - shielded PVC data cable with colour code DIN 47100 for use in machinery and apparatus construction and in measurement, control and regulation
More informationSPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING CABLES FOR RAILWAY TECHNOLOGY. den-belitsky / Fotolia
SPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING CABLES FOR RAILWAY TECHNOLOGY den-belitsky / Fotolia CONTENT OVERVIEW Who we are.........................................................................................................
More informationIndustrial Ethernet Cables
Industrial Ethernet Cables www.sab-worldwide.com INDUSTRIAL ETHERNET CABLES Content page Application of Industrial ETHERNET Cables.........................................................................................
More informationSPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING CABLES FOR CLEAN ROOM TECHNOLOGY. industrieblick / Fotolia
SPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING CABLES FOR CLEAN ROOM TECHNOLOGY industrieblick / Fotolia Content page Who we are............................................................................................................
More informationCables for Railway Technology
Cables for Railway Technology www.sab-worldwide.com Content q In case that you don t find a suitable cable for your special application, we are always prepared to design a cable according to your individual
More informationData sheet Connection line M12 plug straight - RJ45 plug straight 8-pole, X-coded 5.0 m
Page 1/5 Illustrations Dimensional drawing See enlarged drawings at the end of document Product specification shielded M12-plug to RJ45-plug connection line Cat.6, 8-pole M12-connector, X-coded, straight
More informationPRODUCT INFORMATION. UNITRONIC LiYCY. Benefits Overall braid minimises electrical interference Multifunctional application possibilities
Screened data transmission cable with colour code acc. to DIN 47100 : Low-frequency PVC data cable DIN 47100 coded Flexible (0.34mm² multi-wire Maxi TERMI-POINT ) Flame retardant Screened, Instrumentation
More informationTechnical Data Sheet Shielded (CY) PVC Control Cable
Technical Data Sheet Shielded (CY) PVC Control Cable MachFlex 350 CY VDE Registered Tinned Copper Braid Shield (TCB) Excellent Noise Immunity Applications Designed for applications which are installed
More informationwww. h itech controls.com (800) I (303) Click or Call for a Quotel Photo: HELUKABEL Robotic Cables C HELUKABEL
Photo: HELUKABEL Robotic Cables Robotic Cables With over 30 years of experience with cables and lines, we also have the right solutions for the demands placed on the components to be installed by the applications
More informationVDE-registered oil-resistant PVC control cable with black outer sheath for a wide range of applications
VDE-registered oil-resistant PVC control cable with black outer sheath for a wide range of applications - PVC control cable, VDE registered, oil resistant, flexible and UV-resistant for various applications,
More informationData sheet Connection line M12-RJ45 4-pole D-coded AWG m
Page 1/5 Illustrations Dimensional drawing See enlarged drawings at the end of document Product specification shielded M12 to RJ45 Ethernet connection line Cat.5, 4-pole, D-coded (IEC 61076-2-101) M12
More informationFlexible cables for cable chains Catalogue
Flexible cables for cable chains Catalogue 2005.01 TotalChain Total system for... Reducing Costs Assembly Costs - Delivered to you fully assembled Warehouse Costs - Fewer components to stock and maintain
More informationINFORMATION. Hybrid cables. Description
Description INFORMATION This chapter shows the technical data of the hybrid cables available at SEW EURODRIVE. For assignment of hybrid cables to the products, refer to the respective chapters..1 Description
More informationData sheet Connection line M12-RJ45 4-pole D-coded AWG m
Page 1/6 Illustrations Dimensional drawing Wiring See enlarged drawings at the end of document Product specification shielded M12 to RJ45 Ethernet connection line Cat.5, 4-pole, D-coded (IEC 61076-2-101)
More informationSPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING BLUELINE - CABLES FOR SHIPBUILDING.
SPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING BLUELINE - CABLES FOR SHIPBUILDING www.sab-kabel.de CONTENT OVERVIEW Who we are.........................................................................................................
More informationData sheet. Connection line M12 4-pole D-coded 1.0 m. Illustrations P/N 142M1D11010 EAN Product specification. Page 1/
Page 1/6 Illustrations Dimensional drawing Wiring See enlarged drawings at the end of document Product specification shielded M12 Ethernet connection line Cat.5e, 4-pole, D-coded to IEC 61076-2-101 straight
More informationSPECIAL CABLES TEMPERATURE MEASUREMENT CABLE HARNESSING CABLES FOR WIND POWER PLANT. TimSiegert-batcam / Fotolia
SPECIAL CABLES TEMPERATURE MEASUREMENT CABLE HARNESSING made in Viersen CABLES FOR WIND POWER PLANT TimSiegert-batcam / Fotolia CONTENT General < Who we are......................................................................................
More informationÖLFLEX CLASSIC 115 CY
Screened PVC control cable with small outer diameter - PVC control cable, screened and flexible for various applications, thin and light without inner sheath, U 0 /U: 300/500V Info CPR: choice under www.lappkabel.com/cpr
More informationNICHIGOH S CABLE CONTENTS ROBOT CABLE CONTROL CABLE RO-FLEX RO-FLEX RCVV-S 9 VCT-F 11 VCTF 13 MVVS 15 DATA TRANSMISSION CABLE NFKVV-SB 18
0 NICHIGOH S CABLE CONTENTS ROBOT CABLE RO-FLEX3000 2 RO-FLEX3300 5 RCVV-S 9 CONTROL CABLE VCT-F 11 VCTF 13 MVVS 15 DATA TRANSMISSION CABLE NFKVV-SB 18 1 WORLD WIDE STANDARD CABLE RECOGNITION SERIES RO-FLEX3000F
More informationÖLFLEX CLASSIC 110 CY
Screened PVC control cable with transparent outer sheath - PVC control cable, VDE registered, screened, flexible and numbered for various applications, U 0 /U: 300/500V Info CPR: choice under www.lappkabel.com/cpr
More informationCable Assemblies according to Bosch Rexroth Standard
Connectivity Solutions Cable Assemblies according to Bosch Rexroth Standard Copyright Protected trademarks and trade names are not always labelled as such in this publication. This does not mean they are
More informationLANmark-1000 Category 6 Plenum
LANmark-1000 is an ANSI/TIA/EIA Category 6 verified cable that is ideal for gigabit network applications. It introduces new electrical performance parameters which are needed for gigabit Ethernet network
More informationVDE tested single cores according to EN (H05Z-K & H07Z-K) for more demanding requirements
VDE tested single cores according to EN 50525-3-41 (H05Z-K & H07Z-K) for more demanding requirements ÖLFLEX HEAT 125 C MC - halogen free single core with GL certificate, special fire performance, IEC 60332-3,
More informationTechnical Data Sheet Shielded (CY) PVC Control Cable
Technical Data Sheet Shielded (CY) PVC Control Cable MachFlex 375 CY Tinned Copper Braid Shield (TCB) Excellent Noise Immunity Applications Designed for applications which are installed in occasional flexing
More informationTechnical Data Sheet Unshielded (YY) PVC Control Cable
Technical Data Sheet Unshielded (YY) PVC Control Cable MachFlex 350 YY VDE Registered Flexible PVC Control Cables Applications Designed for applications which are installed in occasional flexing and fixed
More informationTechnical Data Sheet Shielded (CY) PVC Control Cable
MachineTuff Cables Tinned Copper Braid Shield (TCB) Excellent Noise Immunity Applications Designed for applications which are installed in occasional flexing and fixed locations. Cable applications include
More informationSPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING CABLES FOR WIND POWER PLANT. TimSiegert-batcam / Fotolia
SPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING CABLES FOR WIND POWER PLANT TimSiegert-batcam / Fotolia CONTENT General < Who we are......................................................................................
More informationTechnical Data Sheet Unshielded (YY) PVC Control Cable
MachineTuff Cables Applications Designed for applications which are installed in occasional flexing and fixed locations. Cable applications include precision control sensors, multi axis control machines,
More informationPRODUCT INFORMATION ÖLFLEX HEAT 125 C MC. Info Improved characteristics in the event of a fire GL - Germanischer Lloyd approved
Electron beam cross-linked cables for more demanding application requirements - halogen free shielded control cable with GL certificate, special fire performance, IEC 60332-3, suitable for +125 C Info
More informationPUR c-track cables For highest requirements
2. C-track cables PUR c-track cables For highest requirements LÜTZE SUPERFLEX PLUS N PUR UL 300 V Machine and device construction, transport and conveyor technology Through full PUR jacket and TPE conductor
More informationTelephone Cables Fire Warning Cables
Telephone Cables Fire Warning Cables Telephone Cables Fire Warning Cables As supplier of underground cables, telephone cables for indoor and outdoor lying, as well as fire warning cables (also the halogen-free
More informationCORDAFLEX(SMK) (N)SHTÖU Tough Rubber-Sheathed Reeling Cables
CORDAFLEX(SMK) (N)SHTÖU Tough Rubber-Sheathed Reeling Cables 3 SK1_1-001.tif 4 SK1_1-003.tif SK1_1-00.tif Selection and dimensioning criteria Refer to Section 4 for further details Ü Type CORDAFLEX(SMK)
More informationPVC motor cables unshielded
PVC motor cables unshielded LÜTZE-SILFLEX M PVC Motor connecting/energy supply cable Motor connecting cable and energy supply cable in machine and apparatus engineering, transport and conveyor technology,
More informationPRODUCT INFORMATION. UNITRONIC SPIRAL LiF2Y11Y. Info New: the unscreened spiral cables with small cross section High restoring forces PUR outer sheath
Spiral cable with outer PUR sheath for exact impulse transmission, unshielded - PUR spiral cable, abrasion-resistant data and control cable for use in data processing, measurement and control engineering
More informationÖLFLEX CLASSIC 135 CH -halogen-free control cable, HFFR, flexible and screened for various applications, U 0 /U: 300/500V
PRODUCT INFORMATION Screened halogen-free control cable with improved fire characteristics -halogen-free control cable, HFFR, flexible and screened for various applications, U 0 /U: 300/500V Info CPR:
More informationUSA: UL-listed (MTW), Canada: CSA (TEW), Europe: <HAR> H07V-K (depending on cross s.), tin-coated strands
USA: UL-listed (MTW), Canada: CSA (TEW), Europe: H07V-K (depending on cross s.), tin-coated strands Lapp Kabel, power and control cable, PVC single core for field wiring, UL MTW VW-1, UL AWM style
More informationPRODUCT INFORMATION H07V-K
GmbH PRODUCT INFORMATION European cable type certification Cables' marking also stands for the international endorsement of national certification institutes' testing marks and certificates,
More informationSABIX Ultra. Standards: EN EN Cat C or D IEC (halogen-free)
SABIX Ultra Standards: EN 60332-1-2 EN 60332-3 Cat C or D IEC 60754-1 (halogen-free) IEC 60754-2 + EN 50267-2-2 (corrosivity of gases) EN 61034 (smoke density) NF C 32-70 C1 (fire performance acc. to French
More informationPRODUCT INFORMATION MULTI-STANDARD SC 2.1. U.I. Lapp GmbH
GmbH PRODUCT INFORMATION USA: UL-listed (MTW), Canada: CSA (TEW), Europe: H07V-K (depending on cross s.), tin-coated strands For use in the most important global markets Reduction in technical documentation
More informationWarehousing...Distribution Centers... Logistics. andling. plastics for longer life ECS-B12
aterial Warehousing...Distribution Centers... Logistics andling plastics for longer life... www.igus.com/materialhandling 1 ECS-B12 igus products... Maintenance-free plastic products in indoor and outdoor
More informationFlame Retardant Individual and Overall Screened, Armoured Instrumentation Cables (Multipair)
Caledonian Flame Retardant Instrumentation Cables www.caledonian-cables.co.uk www.addison-cables.com Flame Retardant Individual and Overall Screened, Armoured Instrumentation Cables (Multipair) RE-2X(st)YSWAY
More informationPRODUCT INFORMATION. ÖLFLEX HEAT 180 SiF
GmbH PRODUCT INFORMATION Versatile stranded conductors with extended temperature range Halogen-free Temperature-resistant Info Flexible fine-wire copper conductor Application range Areas with high ambient
More informationSAC-4P-M12MS/ 5,0-PUR SH
Extract from the online catalog SAC-4P-M12MS/ 5,0-PUR SH Order No.: 1682647 Sensor/Actuator cable, 4-position, PUR, halogen-free, Black-gray RAL 7021, shielded, Plug, straight M12, A-coded, on Free conductor
More informationConnectivity Solutions. Cable assembly in compliance with Bosch Rexroth Standard
Connectivity Solutions Cable assembly in compliance with Bosch Rexroth Standard Welcome to LÜTZE Cable Solutions Efficiency in Automation - These few words reflect our entire company philosophy. Connectivity
More informationÖLFLEX CLASSIC 110 H Info Benefits
Halogen-free control cable, oil resistant and very flexible - halogen-free control cable, HFFR, oil-resistant, very flexible and cold-resistant down to -30 C for various applications, CPR Info CPR: Article
More informationMOTOR, SERVO, & FEEDBACK CABLES
MOTOR, SERVO, & FEEDBACK CABLES Motor, servo, and feedback cables Temperature ( C) - flexing Temperature ( C) - fixed Nominal voltage U 0 /U Bending radius - flexing x Ø Bending radius - fixed x Ø Halogen-free
More informationPRODUCT INFORMATION. ÖLFLEX HEAT 180 SiF. Info Flexible fine-wire copper conductor
Versatile single core cable with extended temperature range - fine wire silicone single core for use in machines, plant construction and toolbuilding for temperatures up to +180 C Info Flexible fine-wire
More informationCABLES FOR AUTOMOTIVE MARKET Sensor and multimedia cables. Catalogue
CABLES FOR AUTOMOTIVE MARKET Sensor and multimedia cables Catalogue Introduction Nexans has developed a range of special and customised cables for the automotive market. This cable range covers two main
More information