EVA-LL / -LLF production transfered to NEXANS France (Andreziéux) S05HH-F now harmonized new "H05Z1Z1-F"

Size: px
Start display at page:

Download "EVA-LL / -LLF production transfered to NEXANS France (Andreziéux) S05HH-F now harmonized new "H05Z1Z1-F""

Transcription

1 Important changes item page to page comment H05V-U/-K/-R production now leadfree H05V2-U/-K/-R production now leadfree H07V-U/-K production now leadfree H07V2-U/-K production now leadfree EVA-LL / -LLF production transfered to NEXANS France (Andreziéux) H03VH7-H production now leadfree H03VV-F; A03VV-F production now leadfree H03VVH2-F production now leadfree H05VV-F; A05VV-F production now leadfree H05VVH2-F production now leadfree S05HH-F now harmonized new "H05Z1Z1-F" S05HHH2-F now harmonized new "H05Z1Z1H2-F" H03VH-H product no longer available NYFAZW product no longer available Status : 12.January 2005 / Mannhof

2 Contents Page(s) General informations CE-marking 3 Harmonization-marking 4 Construction-signs of harmonized cables/ Core identifications 5 and 6 Properties of insulation materials 7 and 8 Packing/ Cable Packs 9 and 10 Pictographs 11 Production program of single-core cables Single-core non-sheathed PVC-Cables for general purposes H05V-U/-K/-R 12 to 17 Single-core non-sheathed PVC-Cables for internal wiring (heat resistant) H05V2-U/-K/-R 18 to 23 Rubber cables for internal wiring (heat resistant) H05G-U/-K 24 to 27 Single-core cables (flame resistant, halogen free) S05H-U/-K 28 to 31 Single-core cables (flame retardant, halogen free, heat resistant) S05H-U/-K/-R (HFFR, 90 C) 32 to 37 Single-core non-sheathed PVC-Cables for general purposes H07V-U/-K 38 to 41 Single-core non-sheathed PVC-Cables for internal wiring (heat resistant) H07V2-U/-K 42 to 45 Rubber cables for internal wiring (heat resistant) H07G-U/-K ; EVA-LL/-LLF ; DE-N07G-U/-K 46 to 59 Single-core cables (flame resistant, halogen free) S07H-U/-K 60 to 63 Single-core cables (flame retardant, halogen free, heat resistant) S07H-U/-K/-R (HFFR, 90 C) 64 to 69 Single-core PVC-Cable for lighting chains H03VH7-H 70 to 71 Light PVC-sheathed cord, circular H03VV-F ; A03VV-F 72 to 75 1

3 Contents Page(s) Production program of multi-core cables Light PVC-sheathed cord, flat H03VVH2-F 76 to 77 Light PVC-sheathed cord, circular (heat resistant) H03V2V2-F 78 to 79 Light PVC-sheathed cord, flat (heat resistant) H03V2V2H2-F 80 to 81 PVC-sheathed cord, circular H05VV-F ; A05VV-F 82 to 85 PVC-sheathed cord, flat H05VVH2-F 86 to 87 PVC-sheathed cord, circular (heat resistant) H05V2V2-F 88 to 89 PVC-sheathed cord, flat (heat resistant) H05V2V2H2-F 90 to 91 Flexible cord, circular (flame retardant, halogen free) S05HH-F 92 to 93 Flexible cord, flat (flame retardant, halogen free) S05HHH2-F 94 to 95 EPR-insulated and PU-sheathed flexible cable H05BQ-F ; H07BQ-F 96 to 99 Non-sheathed PVC-Cord, flat H03VH-H 100 to 101 PVC-Twincable (heat resistant) NYFAZW 102 to 103 2

4 CE-Marking The CE-marking consists of the letters CE (= Communautés Européennes) and the following face: What means the CE-Marking? Our products are signed legitimately with the CE-Marking, which means they meet all basic requirements as can be proved and passed through the prescribed conformity valuation process and therefore are entitled to free trade in the entire European home market (EU/EWR). Their trading and operating in the home market must not be obstructed. According to the low tension guideline it is possible to place the CE-Marking directly on the product, the packing or the covering letters (guarantee, operating instructions etc.). In the case of cables and wires the CE-Marking is not placed on the product itself. Low Tension Guideline 73/23/EWG: Products with a nominal voltage of > 50 to 1000 V a.c. resp. between > 75 to 1500 V d.c. have to be CE-marked since 01. January Attention: The CE-Marking is a proof of the conformity of the guidelines for the control authority. It is not intended for costumers. The CE-Marking is not a guarantee, assurance or sign of norm conformity. It is not a sign of norm conformity even if the fulfillment of the guidelines is demonstrated by harmonized standards. Responsible control authority: According to the arrangements of the law for the safety of appliances the market control is implemented by the industrial board of control because the low tension guideline is transposed as 1.order of the law for the safety of appliances. 3

5 Harmonization-Marking The common marking ( HAR ) shows that the production place is judged and subject to continuous plant controls corresponding with technical proceedings of a national approved office of license (in Germany: VDE). The following table contents all member countries which are obliged according to the arrangements of CENELEC (Comité Européen de Normalisation Electrotechnique) to observe certain standards of the IEC (International Electrotechnical Comission) as well as European standards and harmonization documents. Country: national office of certification HARmonization- HARmonization- Marking as Marking as black-red-yellow printing or identification thread embossing (length of colours in cm) black red yellow Belgium: Comité Electrotechnique Belge (CEBEC) CEBEC HAR Denmark: Danmarks Elektriske Materielkontrol (DEMKO) DEMKO HAR Germany: Verband Deutscher Elektrotechniker (VDE) e.v. VDE Prüf- und Zertifizierungsinstitut VDE Prüfstelle VDE HAR Finland: Elektriska Inspektoratet (FIMKO) FIMKO HAR France: Laboratoire Central des Industries Electriques (LCIE) USE HAR Greece: Hellenic Organization for Standardization (ELOT) ELOT HAR Ireland: National Standards Authority of Ireland (NSAI) NSAI HAR Italy: Istituto Italiano del Marchio Qualità (IMQ) IEMMEQU HAR Netherlands: N.V. tot Keuring van Elektrotechnische Materialien (KEMA) KEMA-KEUR HAR Norway: Norges Elektriske Materiallkontroll (NEMKO) NEMKO HAR Austria: Österreichischer Verband für Elektrotechnik (ÖVE) ÖVE HAR Portugal: CERTIF CERTIF HAR Sweden: Svenska Elektriska Materielkontrollanstalten (SEMKO) SEMKO HAR Switzerland: Schweizerischer Elektrotechnischer Verein (SEV) SEV HAR Spain: Asociación Espanola de Normalización Y Certificación (AENOR) AENOR HAR Great Britain and Northern Ireland: British Approvals Service for Cables (BASEC) BASEC HAR Hungary: Magyar Elektrotechnikai Ellenörzö Intézet (MEEI) MEEI HAR TurkeyW: TSE Türk Stanardlari Enstitüsü TSE HAR

6 Construction abbreviations of harmonized wires Type of determination and nominal voltage Identification of determination Harmonized determination Approved national Type H A H 05V2V2H2 -F Nominal voltage U0/U 300 / 300 V / 500 V / 750 V 07 Construction of wires Insulation material PVC standard up to + 70 C V PVC heat resistant up to + 90 C V2 PVC crosslinked V4 Nature- and/or synthetic caoutchouc up to + 60 C R Synthetic caoutchouc (EVA) up to C G Ethylene-propylene-caoutchouc up to + 90 C B Halogen free crosslinked compound (Polyolefine Basis) Z Halogen free thermoplastic compound (Polyolefine Basis) Z1 Sheat material PVC standard up to + 60 C V PVC heat resistant up to + 90 C V2 PVC crosslinked V4 Polyurethane Q Nature- and/or synthetic caoutchouc up to + 60 C R Chloroprene caoutchouc (EVA) up to + 60 C N Synthetic caoutchouc (EVA) up to C G Special qualities in construction flat, dividable wire flat, non-dividable wire Dual-layed extruded wire for lighting chains coil-suitable wire H H2 H7 H8 Type of conductor single-core -U multi-core -R flexible, for fixed laying -K flexible -F extra flexible -H Number and cross-section of conductor Number of cores... Earth-wire without earth-wire X with earth-wire green-yellow G Nominal cross-section of conductor in mm

7 Construction abbreviations Core identification Examples: H07V-K 1X1,5 bk PVC-cable 1,5mm 2 with flexible conductor, nominal voltage U0/U 450/750 V, single-core with green-yellow earth-wire, core colour black H03V2V2H2-F 2X0,75 PVC-cord with flexible conductor 0,75mm 2, nominal voltage U0/U 300/300 V, 2-core, heat resistant up to + 90 C, flat type Core-marking and sequence of colours Multi-core flexible cables with 2 to 5 cores Number of cores Cables with green-yellow cores Cables without green-yellow cores 6

8 Properties of insulation materials Abbreviations Type of Continuous Density Hardness Tensile Elongation Flame Halogen compound operating strength at break resistance free acc. to temperature VDE resp. HD limit C acc. to VDE g/cm 3 Shore A N/mm 2 % Thermoplastics PVC-P TI1 70 1,45-1, > 12,5 > 125 yes no PVC-P (h)* TI3/YI8 90/105 1,30-1, > 15,0 > 150 yes no PVC-P TM2 70 1,30-1, > 10,0 > 150 yes no PVC-P (h)* TM3/YM4 90/105 1,25-1, > 15,0 > 150 yes no Thermoplastic Elastomers TPE-U 90 1,10-1, > 25,0 > 300 no yes (Urethane) Thermoplastics cross-linked by irradiation X-PVC (XI2) 80 1,35-1, > 15,0 > 150 yes no X-PVC (XM2) 70 1,30-1, > 10,0 > 150 yes no Elastomers EVA EI ,40-1, > 6,5 > 200 no yes EPR EI4 60 1,45-1, > 5,0 > 200 no yes (h)* = heat resistant 7

9 Properties of the insulation materials Abbreviations Chemical properties General properties Thermoplastics PVC-P PVC-P (h)* Resistant to: oils, greases, diluted acids and alkalis up to 50 C. Specific compounds resistant to solvents. Flexibility adjustable over a wide range, colours well, also translucent to transparent. Resistance to stress-cracking, good weathering resistance. Radiation resistance: 10 5 Gy Thermoplastic Elastomers TPE-U (Urethane) Good resistant to: oils, greases, petrols and solvents. Resistant to: diluted acids and alkalis. Resistant to hydrolisis Very good resistance to weathering. Fungus resistant. Radiation resistance: 5x10 6 Gy Strahlenvernetzte Thermoplaste X-PVC Resistant to: diluted acids, alkalis, oils and greases. Good resistance to solvents. Improved mechanical properties especially at increased temperatures, high abrasion resistance, no melting away of the insulation upon contact with hot parts, resistant to soldering irons, short-circuit proof. Elastomers EVA EPR Resistant to: diluted acids and alkalis. Little resistance to: oils, greases and solvents. Resistant to: diluted acids and alkalis. Moderately resistance to: oils, greases and solvents. Good resistance to weathering and ozone. Radiation resistance: bis 10 6 Gy Good resistance to ozone ; good electric and dielectric properties. Resistant to: water and weathering Radiation resistance: 10 6 Gy (h)* = heat resistant 8

10 Packing/ Cable Packs The Wire-Coil The continuous challenge in reducing waste and packing resulted in the development of specific wire-coils. Throught the new concept to deliver wire-coils depending on the types, one or six coils are on a Euro-flat-pallet an extremely efficient compact-form has been realized. Receycable foils and card board cores and an optimal exploitation of space lead to a considerable reduction of transport and storage costs. Summarising these aspects we reached an essential contribution to connect economy and ecology. The new wire-coils AC4 and AC8 stand for Compact The relation coil-volume/wirevolume with 2:1 is very good Space-saving Good exlpoitation of storage places, 3 palettes can be stacked Economic No more handling after working up, no back-transportation Safe Outstanding Non-polluting All materials belonging to the make-up are recycable Coil AC4 Size 400x400 mm (WxH) Packaging: 6 Coils on a palett, each Coil fixed with fasterners whole palett. Shrinked with PE-foil Coil AC8 Size 800x600 mm (WxH) Packaging: 1Coil on a palett (1200x800 mm). Coil fixed with 4 fastenen whole palett. Shrinked with PE-foil 9

11 Coil-Handling Place AC4 coils in front off your equipment and remove recycable fasteners. If higher processing speeds are needed we recommend to use a cover preventing the cable from getting stock. AC8 coils can be processed directly off the palett. Maximum processing speed for AC4 coils 600 m/min. AC8 coils 300 m/min. Types Lenght/ km mm 2 Coil AC4 Barrel 800x400 Coil AC8 Drums Y08 H05V-U/K 0,5 6,5 8 0,75 5,0 8 1,0 4 6 H05V-R 0,5 5,7 8 0,75 5,0 8 1,0 4,0 6 H05V2-U 0,5 6,5 8 0,75 5,0 8 1,0 4,0 6 H05V2-K 0,5 6,5 8 0,75 5,0 8 1,0 4 6 H05V2-R 0,5 5,7 8 0,75 5,0 8 1,0 4,0 6 H07V-U/K 1, , ,2 2,6 H07V2-U 1, , ,2 2,6 H03VV-F 2 X 0,5 6,5 4 2 X 0, G 0, G 0,75 5,5 3 H05VV-F 2 X 0,75 5,0 2,5 3 G 0,75 4,5 2,7 2 X 1,0 4,2 3,0 3 G 1,0 3,7 2,6 2 X 1,5 3,0 2 3 G 1,5 2,7 1,9 10

12 Pictographs operating temperature weather resistant mechanical resistant resistant to chemicals flame retarding low smoke low corrosive no toxic flexibility Cl Br Fl halogen-free lead-free 11

13 H05V-U Single-core non-sheathed cable for general purposes Type Approval Certificates DIN VDE 0281, part 3 HD 21.3 Applications Fixed protected installation inside appliances and in, or on, lighting fittings 300/500 V Max permissible temperature: + 70 C Design 1. Conductor Solid copper class 1 acc. to DIN VDE Insulation PVC-compound TI1 acc. to DIN VDE 0281, part 1 Marking X NEXANS X VDE HAR Core identification Colour code acc. to DIN VDE 0293 Cl Br Fl + 5 C/+ 70 C no no no 12

14 H05V-U Technical data Nominal Diameter Conductor Wall Mean Minimum Weight Copper cross-sectional of resistance thickness overall insulation content area of conductor at 20 C insulation diameter resistance conductor at 70 C NV SV max. NV SV LV SV SV mm 2 mm Ω/km mm mm MΩ km kg/km kg/km 0,5 0,8 36,0 0,6 2,0 0, ,8 0,75 1,0 24,5 0,6 2,2 0, ,2 1 1,2 18,1 0,6 2,4 0, ,6 NV = nominal value LV = lowest value SV = standard value August 2001 Copyright 2001 Nexans 13 Nexans Deutschland Industries - Industrial Applications Sieboldstraße Nürnberg - Germany Tel.: +49 (0) 911/ Fax: +49 (0)911/

15 H05V-K Single-core non-sheathed cable for general purposes Type Approval Certificates DIN VDE 0281, part 3 HD 21.3 Applications Fixed protected installation inside appliances and in, or on, lighting fittings 300/500 V Max permissible temperature: + 70 C Design 1. Conductor Flexible copper class 5 acc. to DIN VDE Insulation PVC-compound TI1 acc. to DIN VDE 0281, part 1 Marking X NEXANS X VDE HAR Core identification Colour code acc. to DIN VDE 0293 Cl Br Fl + 5 C/+ 70 C yes no no 14

16 H05V-K Technical data Nominal Diameter Diameter Conductor Wall Mean Minimum Weight Copper cross- of single of resistance thickness overall insulation content sectional wires of the conductor at 20 C insulation diameter resistance area of conductor at 70 C conductor NV HV SV max. NV SV LV SV SV mm 2 mm mm Ω/km mm mm MΩ km kg/km kg/km 0,5 0,21 0,9 39,0 0,6 2,1 0, ,8 0,75 0,21 1,1 26,0 0,6 2,3 0, ,2 1 0,21 1,3 19,5 0,6 2,5 0, ,6 NV = nominal value HV = highest value LV = lowest value SV = standard value August 2001 Copyright 2001 Nexans 15 Nexans Deutschland Industries - Industrial Applications Sieboldstraße Nürnberg - Germany Tel.: +49 (0) 911/ Fax: +49 (0)911/

17 H05V-R Single-core non-sheathed cable for general purposes Type Approval Certificates DIN VDE 0281, part 3 HD 21.3 Applications Fixed protected installation inside appliances and in, or on, lighting fittings 300/500 V Max permissible temperature: + 70 C Design 1. Conductor Stranded copper class 2 acc. to DIN VDE Insulation PVC-compound TI1 acc. to DIN VDE 0281, part 1 Marking X NEXANS X VDE HAR Core identification Colour code acc. to DIN VDE 0293 Cl Br Fl + 5 C/+ 70 C no no no 16

18 H05V-R Technical data Nominal Diameter Diameter Conductor Wall Mean Minimum Weight Copper cross- of single of resistance thickness overall insulation content sectional wires of the conductor at 20 C insulation diameter resistance area of conductor at 70 C conductor NV HV SV max. NV SV LV SV SV mm 2 mm mm Ω/km mm mm MΩ km kg/km kg/km 0,5 0,3 0,9 36,0 0,6 2,1 0, ,8 0,75 0,37 1,1 24,5 0,6 2,3 0, ,2 1 0,43 1,3 18,1 0,6 2,5 0, ,6 NV = nominal value HV = highest value LV = lowest value SV = standard value August 2001 Copyright 2001 Nexans 17 Nexans Deutschland Industries - Industrial Applications Sieboldstraße Nürnberg - Germany Tel.: +49 (0) 911/ Fax: +49 (0)911/

19 H05V2-U Single-core non-sheathed cable for internal wiring Type Approval Certificates DIN VDE 0281, part 7 HD 21.7 Applications For internal wiring and fixed protected installation inside appliances and in lighting fittings 300/500 V Max permissible temperature: + 90 C Design 1. Conductor Solid copper class 1 acc. to DIN VDE Insulation Heat resistant PVC-compound TI3 acc. to DIN VDE 0281, part 1 Marking X NEXANS X VDE HAR 05V2 Core identification Colour code acc. to DIN VDE 0293 Cl Br Fl + 5 C/+ 90 C no no no 18

20 H05V2-U Technical data Nominal Diameter Conductor Wall Mean Minimum Weight Copper cross-sectional of resistance thickness overall insulation content area of conductor at 20 C insulation diameter resistance conductor at 90 C NV SV max. NV SV LV SV SV mm 2 mm Ω/km mm mm MΩ km kg/km kg/km 0,5 0,8 36,0 0,6 2,0 0, ,8 0,75 1,0 24,5 0,6 2,2 0, ,2 1 1,2 18,1 0,6 2,4 0, ,6 NV = nominal value LV = lowest value SV = standard value August 2001 Copyright 2001 Nexans 19 Nexans Deutschland Industries - Industrial Applications Sieboldstraße Nürnberg - Germany Tel.: +49 (0) 911/ Fax: +49 (0)911/

21 H05V2-K Single-core non-sheathed cable for internal wiring Type Approval Certificates DIN VDE 0281, part 7 HD 21.7 Applications For internal wiring and fixed protected installation inside appliances and in lighting fittings 300/500 V Max permissible temperature: + 90 C Design 1. Conductor Flexible copper class 5 acc. to DIN VDE Insulation Heat resistant PVC-compound TI3 acc. to DIN VDE 0281, part 1 Marking X NEXANS X VDE HAR 05V2 Core identification Colour code acc. to DIN VDE 0293 Cl Br Fl + 5 C/+ 90 C yes no no 20

22 H05V2-K Technical data Nominal Diameter Diameter Conductor Wall Mean Minimum Weight Copper cross- of single of resistance thickness overall insulation content sectional wires of the conductor at 20 C insulation diameter resistance area of conductor at 90 C conductor NV HV SV max. NV SV LV SV SV mm 2 mm mm Ω/km mm mm MΩ km kg/km kg/km 0,5 0,21 0,9 39,0 0,6 2,1 0, ,8 0,75 0,21 1,1 26,0 0,6 2,3 0, ,2 1 0,21 1,3 19,5 0,6 2,5 0, ,6 NV = nominal value HV = highest value LV = lowest value SV = standard value August 2001 Copyright 2001 Nexans 21 Nexans Deutschland Industries - Industrial Applications Sieboldstraße Nürnberg - Germany Tel.: +49 (0) 911/ Fax: +49 (0)911/

23 H05V2-R Single-core non-sheathed cable for internal wiring Type Approval Certificates DIN VDE 0281, part 7 HD 21.7 Applications For internal wiring and fixed protected installation inside appliances and in lighting fittings 300/500 V Max permissible temperature: + 90 C Design 1. Conductor Stranded copper class 2 acc. to DIN VDE Insulation Heat resistant PVC-compound TI3 acc. to DIN VDE 0281, part 1 Marking X NEXANS X VDE HAR 05V2 Core identification Colour code acc. to DIN VDE 0293 Cl Br Fl + 5 C/+ 90 C no no no 22

24 H05V-R Technical data Nominal Diameter Diameter Conductor Wall Mean Minimum Weight Copper cross- of single of resistance thickness overall insulation content sectional wires of the conductor at 20 C insulation diameter resistance area of conductor at 90 C conductor NV HV SV max. NV SV LV SV SV mm 2 mm mm Ω/km mm mm MΩ km kg/km kg/km 0,5 0,3 0,9 36,0 0,6 2,1 0, ,8 0,75 0,37 1,1 24,5 0,6 2,3 0, ,2 1 0,43 1,3 18,1 0,6 2,5 0, ,6 NV = nominal value HV = highest value LV = lowest value SV = standard value August 2001 Copyright 2001 Nexans 23 Nexans Deutschland Industries - Industrial Applications Sieboldstraße Nürnberg - Germany Tel.: +49 (0) 911/ Fax: +49 (0)911/

25 H05G-U Cable with increased heat resistance for internal wiring Type Approval Certificates DIN VDE 0282, part 7 HD 22.7 Applications For internal wiring in dry locations only. For fixed installations elsewhere e.g. visible or embedded conduits or tubes. 300/500 V Max permissible temperature: C Design 1. Conductor Solid copper wire tinned class 1 acc. to DIN VDE Insulation Heat resistant rubbercompound EI3 acc. to DIN VDE 0282, part 1 Marking X NEXANS X VDE HAR 05G Core identification Colour code acc. to DIN VDE 0293 Cl Br Fl - 25 C/+ 110 C no good good yes 24

26 H05G-U Technical data Nominal Diameter Conductor Wall Mean Minimum Weight Copper cross-sectional of resistance thickness overall insulation content area of conductor at 20 C insulation diameter resistance conductor at 110 C NV SV max. NV SV LV SV SV mm 2 mm Ω/km mm mm MΩ km kg/km kg/km 0,5 0,8 36,7 0,6 2,0 0, ,8 0,75 1,0 24,8 0,6 2,2 0, ,2 1 1,2 18,2 0,6 2,4 0, ,6 NV = nominal value LV = lowest value SV = standard value August 2001 Copyright 2001 Nexans 25 Nexans Deutschland Industries - Industrial Applications Sieboldstraße Nürnberg - Germany Tel.: +49 (0) 911/ Fax: +49 (0)911/

27 H05G-K Cable with increased heat resistance for internal wiring Type Approval Certificates DIN VDE 0282, part 7 HD 22.7 Applications For internal wiring in dry locations only. For fixed installations elsewhere e.g. visible or embedded conduits or tubes. 300/500 V Max permissible temperature: C Design 1. Conductor Flexible copper tinned class 5 acc. to DIN VDE Insulation Heat resistant rubbercompound EI3 acc. to DIN VDE 0282, part 1 Marking X NEXANS X VDE HAR 05G Core identification Colour code acc. to DIN VDE 0293 Cl Br Fl - 25 C/+ 110 C yes good good yes 26

28 H05G-K Technical data Nominal Diameter Diameter Conductor Wall Mean Minimum Weight Copper cross- of single of resistance thickness overall insulation content sectional wires of the conductor at 20 C insulation diameter resistance area of conductor at 110 C conductor NV HV SV max. NV SV LV SV SV mm 2 mm mm Ω/km mm mm MΩ km kg/km kg/km 0,5 0,21 0,9 40,1 0,6 2,2 0, ,8 0,75 0,21 1,1 26,7 0,6 2,3 0, ,2 1 0,21 1,3 20,0 0,6 2,5 0, ,6 NV = nominal value HV = highest value LV = lowest value SV = standard value August 2001 Copyright 2001 Nexans 27 Nexans Deutschland Industries - Industrial Applications Sieboldstraße Nürnberg - Germany Tel.: +49 (0) 911/ Fax: +49 (0)911/

29 S05H-U Halogen free and flame resistant single-core cable Type Approval Certificates VDE-Reg.-Nr Applications For internal wiring of appliances and for protected laying in and on luminaries. Suitable for installation in surface mounted or embedded conduits only for signalling circuits. 300/500 V Max permissible temperature: + 70 C Design 1. Conductor Solid copper class 1 acc. to DIN VDE Insulation Compound of polyolefine, halogen free, flame restistant Marking X NEXANS X VDE-REG.-NR S05H(HFFR) Core identification Colour code acc. to DIN VDE 0293 Cl Br Fl +5 C/+70 C good no yes yes yes yes yes yes 28

30 S05H-U Technical data Nominal Diameter Conductor Wall Mean Minimum Weight Copper cross-sectional of resistance thickness overall insulation content area of conductor at 20 C insulation diameter resistance conductor at 70 C NV SV max. NV SV LV SV SV mm 2 mm Ω/km mm mm MΩ km kg/km kg/km 0,5 0,8 36,0 0,6 2,0 0, ,8 0,75 1,0 24,5 0,6 2,2 0, ,2 1 1,2 18,1 0,6 2,4 0, ,6 NV = nominal value LV = lowest value SV = standard value August 2001 Copyright 2001 Nexans 29 Nexans Deutschland Industries - Industrial Applications Sieboldstraße Nürnberg - Germany Tel.: +49 (0) 911/ Fax: +49 (0)911/

31 S05H-K Halogen free and flame resistant single-core cable Type Approval Certificates VDE-Reg.-Nr Applications For internal wiring of appliances and for protected laying in and on luminaries. Suitable for installation in surface mounted or embedded conduits only for signalling circuits. 300/500 V Max permissible temperature: + 70 C Design 1. Conductor Flexible copper class 5 acc. to DIN VDE Insulation Compound of polyolefine, halogen free, flame restistant Marking X NEXANS X VDE-REG.-NR S05H(HFFR) Core identification Colour code acc. to DIN VDE 0293 Cl Br Fl +5 C/+70 C good yes yes yes yes yes yes yes 30

32 S05H-K Technical data Nominal Diameter Diameter Conductor Wall Mean Minimum Weight Copper cross- of single of resistance thickness overall insulation content sectional wires of the conductor at 20 C insulation diameter resistance area of conductor at 70 C conductor NV HV SV max. NV SV LV SV SV mm 2 mm mm Ω/km mm mm MΩ km kg/km kg/km 0,5 0,21 0,9 39,0 0,6 2,1 0, ,8 0,75 0,21 1,1 26,0 0,6 2,3 0, ,2 1 0,21 1,3 19,5 0,6 2,5 0, ,6 NV = nominal value HV = highest value LV = lowest value SV = standard value August 2001 Copyright 2001 Nexans 31 Nexans Deutschland Industries - Industrial Applications Sieboldstraße Nürnberg - Germany Tel.: +49 (0) 911/ Fax: +49 (0)911/

33 S05H-U (HFFR, 90 ) Halogen free, flame retardant and heat resistant single-core cable Type Approval Certificates VDE-Reg.-Nr Applications For internal wiring of appliances e.g. in or on luminaries. Must not get in touch with hot parts of more than 90 C. Can be used the same way as the heat resistant cores H05V2/ H07V2 acc. to DIN VDE 0281, part /500 V Max permissible temperature: + 90 C Design 1. Conductor Solid copper class 1 acc. to DIN VDE Insulation Compound of polyolefine, halogen free, flame restistant, heat resistant Marking X NEXANS X VDE-REG.-NR S05H (HFFR 90 C) Core identification Colour code acc. to DIN VDE 0293 Cl Br Fl +5 C/+90 C good no yes yes yes yes yes yes 32

34 S05H-U (HFFR, 90 ) Technical data Nominal Diameter Conductor Wall Mean Minimum Weight Copper cross-sectional of resistance thickness overall insulation content area of conductor at 20 C insulation diameter resistance conductor at 90 C NV SV max. NV SV LV SV SV mm 2 mm Ω/km mm mm MΩ km kg/km kg/km 0,5 0,8 36,0 0,6 2,0 0, ,8 0,75 1,0 24,5 0,6 2,2 0, ,2 1 1,2 18,1 0,6 2,4 0, ,6 NV = nominal value HV = highest value LV = lowest value SV = standard value August 2001 Copyright 2001 Nexans 33 Nexans Deutschland Industries - Industrial Applications Sieboldstraße Nürnberg - Germany Tel.: +49 (0) 911/ Fax: +49 (0)911/

35 S05H-K (HFFR, 90 ) Halogen free, flame retardant and heat resistant single-core cable Type Approval Certificates VDE-Reg.-Nr Applications For internal wiring of appliances e.g. in or on luminaries. Must not get in touch with hot parts of more than 90 C. Can be used the same way as the heat resistant cores H05V2/ H07V2 acc. to DIN VDE 0281, part /500 V Max permissible temperature: + 90 C Design 1. Conductor Flexible copper class 5 acc. to DIN VDE Insulation Compound of polyolefine, halogen free, flame restistant, heat resistant Marking X NEXANS X VDE-REG.-NR S05H (HFFR 90 C) Core identification Colour code acc. to DIN VDE 0293 Cl Br Fl +5 C/+90 C good yes yes yes yes yes yes yes 34

36 S05H-K (HFFR, 90 ) Technical data Nominal Diameter Diameter Conductor Wall Mean Minimum Weight Copper cross- of single of resistance thickness overall insulation content sectional wires of the conductor at 20 C insulation diameter resistance area of conductor at 90 C conductor NV HV SV max. NV SV LV SV SV mm 2 mm mm Ω/km mm mm MΩ km kg/km kg/km 0,5 0,21 0,9 39,0 0,6 2,1 0, ,8 0,75 0,21 1,1 26,0 0,6 2,3 0, ,2 1 0,21 1,3 19,5 0,6 2,5 0, ,6 NV = nominal value HV = highest value LV = lowest value SV = standard value August 2001 Copyright 2001 Nexans 35 Nexans Deutschland Industries - Industrial Applications Sieboldstraße Nürnberg - Germany Tel.: +49 (0) 911/ Fax: +49 (0)911/

37 S05H-R (HFFR, 90 ) Halogen free, flame retardant and heat resistant core cable Type Approval Certificates VDE-Reg.-Nr Applications For internal wiring of appliances e.g. in or on luminaries. Must not get in touch with hot parts of more than 90 C. Can be used the same way as the heat resistant cores H05V2/ H07V2 acc. to DIN VDE 0281, part /500 V Max permissible temperature: + 90 C Design 1. Conductor Stranded copper class 2 acc. to DIN VDE Insulation Compound of polyolefine, halogen free, flame restistant, heat resistant Marking X NEXANS X VDE-REG.-NR S05H (HFFR 90 C) Core identification Colour code acc. to DIN VDE 0293 Cl Br Fl +5 C/+90 C good no yes yes yes yes yes yes 36

38 S05H-R (HFFR, 90 ) Technical data Nominal Construction Diameter Conductor Wall Mean Minimum Weight Copper cross- of of resistance thickness overall insulation content sectional conductor conductor at 20 C insulation diameter resistance area of at 90 C conductor NV HV SV max. NV SV LV SV SV mm 2 mm mm Ω/km mm mm MΩ km kg/km kg/km 0,5 0,30 0,9 36,0 0,6 2,1 0, ,8 0,75 0,37 1,1 24,5 0,6 2,3 0, ,2 1 0,43 1,3 18,1 0,6 2,5 0, ,6 NV = nominal value HV = highest value LV = lowest value SV = standard value August 2001 Copyright 2001 Nexans 37 Nexans Deutschland Industries - Industrial Applications Sieboldstraße Nürnberg - Germany Tel.: +49 (0) 911/ Fax: +49 (0)911/

39 H07V-U Single-core non-sheathed cable for general purposes Type Approval Certificates DIN VDE 0281, part 3 HD 21.3 Applications Installation in surface mounted or embedded conduits, or similar closed systems 450/750 V Max permissible temperature: + 70 C Design 1. Conductor Solid copper class 1 acc. to DIN VDE Insulation PVC-compound TI1 acc. to DIN VDE 0281, part 1 Marking X NEXANS X VDE HAR Core identification Colour code acc. to DIN VDE 0293 Cl Br Fl + 5 C/+ 70 C no no no 38

40 H07V-U Technical data Nominal Diameter Conductor Wall Mean Minimum Weight Copper cross-sectional of resistance thickness overall insulation content area of conductor at 20 C insulation diameter resistance conductor at 70 C NV SV max. NV SV LV SV SV mm 2 mm Ω/km mm mm MΩ km kg/km kg/km 1,5 1,4 12,1 0,7 2,8 0, ,4 2,5 1,8 7,41 0,8 3,4 0, ,0 4 2,3 4,61 0,8 4,1 0, ,4 6 2,8 3,08 0,8 4,4 0, ,6 NV = nominal value LV = lowest value SV = standard value August 2001 Copyright 2001 Nexans 39 Nexans Deutschland Industries - Industrial Applications Sieboldstraße Nürnberg - Germany Tel.: +49 (0) 911/ Fax: +49 (0)911/

41 H07V-K Single-core non-sheathed cable for general purposes Type Approval Certificates DIN VDE 0281, part 3 HD 21.3 Applications Installation in surface mounted or embedded conduits, or similar closed systems 450/750 V Max permissible temperature: + 70 C Design 1. Conductor Flexible copper class 5 acc. to DIN VDE Insulation PVC-compound TI1 acc. to DIN VDE 0281, part 1 Marking X NEXANS X VDE HAR Core identification Colour code acc. to DIN VDE 0293 Cl Br Fl + 5 C/+ 70 C yes no no 40

42 H07V-K Technical data Nominal Diameter Diameter Conductor Wall Mean Minimum Weight Copper cross- of of resistance thickness overall insulation content sectional single wires conductor at 20 C insulation diameter resistance area of of the at 70 C conductor conductor NV HV SV max. NV SV LV SV SV mm 2 mm mm Ω/km mm mm MΩ km kg/km kg/km 1,5 0,26 1,6 13,3 0,7 3,0 0, ,4 2,5 0,26 2,1 7,98 0,8 3,6 0, ,0 4 0,31 2,6 4,95 0,8 4,2 0, ,4 6 0,31 3,2 3,30 0,8 4,7 0, ,6 10 0,41 4,0 1,91 1,0 6,3 0, ,0 16 0,41 5,1 1,21 1,0 7,6 0, ,6 25 0,41 6,2 0,780 1,2 9,5 0, ,0 35 0,41 7,7 0,554 1,2 10,2 0, ,0 NV = nominal value HV = highest value LV = lowest value SV = standard value August 2001 Copyright 2001 Nexans 41 Nexans Deutschland Industries - Industrial Applications Sieboldstraße Nürnberg - Germany Tel.: +49 (0) 911/ Fax: +49 (0)911/

43 H07V2-U Single-core non-sheathed cable for internal wiring Type Approval Certificates DIN VDE 0281, part 7 HD 21.7 Applications For internal wiring and fixed protected installation inside appliances and in lighting fittings 450/750 V Max permissible temperature: + 90 C Design 1. Conductor Solid copper class 1 acc. to DIN VDE Insulation Heat resistant PVC-compound TI3 acc. to DIN VDE 0281, part 1 Marking X NEXANS X VDE HAR 07V2 Core identification Colour code acc. to DIN VDE 0293 Cl Br Fl + 5 C/+ 90 C no no no 42

44 H07V2-U Technical data Nominal Diameter Conductor Wall Mean Minimum Weight Copper cross-sectional of resistance thickness overall insulation content area of conductor at 20 C insulation diameter resistance conductor at 90 C NV SV max. NV SV LV SV SV mm 2 mm Ω/km mm mm MΩ km kg/km kg/km 1,5 1,4 12,1 0,7 2,8 0, ,4 2,5 1,8 7,41 0,8 3,4 0, ,0 4 2,3 4,61 0,8 4,1 0, ,4 6 2,8 3,08 0,8 4,4 0, ,6 NV = nominal value LV = lowest value SV = standard value August 2001 Copyright 2001 Nexans 43 Nexans Deutschland Industries - Industrial Applications Sieboldstraße Nürnberg - Germany Tel.: +49 (0) 911/ Fax: +49 (0)911/

45 H07V2-K Single-core non-sheathed cable for general purposes Type Approval Certificates DIN VDE 0281, part 7 HD 21.7 Applications For internal wiring and fixed protected installation inside appliances and in lighting fittings 450/750 V Max permissible temperature: + 90 C Design 1. Conductor Flexible copper class 5 acc. to DIN VDE Insulation Heat resistant PVC-compound TI3 acc. to DIN VDE 0281, part 1 Marking X NEXANS X VDE HAR 07V2 Core identification Colour code acc. to DIN VDE 0293 Cl Br Fl + 5 C/+ 90 C yes no no 44

46 H07V2-K Technical data Nominal Diameter Diameter Conductor Wall Mean Minimum Weight Copper cross- of of resistance thickness overall insulation content sectional single wires conductor at 20 C insulation diameter resistance area of of the at 90 C conductor conductor NV HV SV max. NV SV LV SV SV mm 2 mm mm Ω/km mm mm MΩ km kg/km kg/km 1,5 0,26 1,6 13,3 0,7 3,0 0, ,4 2,5 0,26 2,1 7,98 0,8 3,6 0, ,0 4 0,31 2,6 4,95 0,8 4,2 0, ,4 6 0,31 3,2 3,30 0,8 4,7 0, ,6 10 0,41 4,0 1,91 1,0 6,3 0, ,0 16 0,41 5,1 1,21 1,0 7,6 0, ,6 25 0,41 6,2 0,780 1,2 9,5 0, ,0 35 0,41 7,7 0,554 1,2 10,2 0, ,0 NV = nominal value HV = highest value LV = lowest value SV = standard value August 2001 Copyright 2001 Nexans 45 Nexans Deutschland Industries - Industrial Applications Sieboldstraße Nürnberg - Germany Tel.: +49 (0) 911/ Fax: +49 (0)911/

47 H07G-U Cable with increased heat resistance for internal wiring Type Approval Certificates DIN VDE 0282, part 7 HD 22.7 Applications For internal wiring in dry locations only. For fixed installations elsewhere e.g. visible or embedded conduits or tubes. 450/750 V Max permissible temperature: C Design 1. Conductor Solid copper tinned class 1 acc. to DIN VDE Insulation Heat resistant rubbercompound EI3 acc. to DIN VDE 0282, part 1 Marking X NEXANS X VDE HAR 07G Core identification Colour code acc. to DIN VDE 0293, earth-wire green-yellow Cl Br Fl - 25 C/+ 110 C no good good yes 46

48 H07G-U Technical data Nominal Diameter Conductor Wall Mean Minimum Weight Copper cross-sectional of resistance thickness overall insulation content area of conductor at 20 C insulation diameter resistance conductor at 110 C NV SV max. NV SV LV SV SV mm 2 mm Ω/km mm mm MΩ km kg/km kg/km 1,5 1,35 12,2 0,8 3,0 0, ,4 2,5 1,75 7,56 0,9 3,6 0, ,0 NV = nominal value LV = lowest value SV = standard value August 2001 Copyright 2001 Nexans 47 Nexans Deutschland Industries - Industrial Applications Sieboldstraße Nürnberg - Germany Tel.: +49 (0) 911/ Fax: +49 (0)911/

49 H07G-K Cable with increased heat resistance for internal wiring Type Approval Certificates DIN VDE 0282, part 7 HD 22.7 Applications For internal wiring in dry locations only. For fixed installations elsewhere e.g. visible or embedded conduits or tubes. 450/750 V Max permissible temperature: C Design 1. Conductor Flexible copper wires tinned class 5 acc. to DIN VDE Insulation Heat resistant rubbercompound EI3 acc. to DIN VDE 0282, part 1 Marking X NEXANS X VDE HAR 07G Core identification Colour code acc. to DIN VDE 0293, earth-wire green-yellow Cl Br Fl - 25 C/+ 110 C yes good good yes 48

50 H07G-K Technical data Nominal Diameter Diameter Conductor Wall Mean Minimum Weight Copper cross- of single of resistance thickness overall insulation content sectional wires of the conductor at 20 C insulation diameter resistance area of conductor at 110 C conductor NV HV SV max. NV SV LV SV SV mm 2 mm mm Ω/km mm mm MΩ km kg/km kg/km 1,5 0,26 1,5 13,7 0,8 3,2 0, ,4 2,5 0,26 2,0 8,21 0,9 4,0 0, ,0 4 0,31 2,6 5,09 1,0 4,6 0, ,4 6 0,31 3,0 3,39 1,0 5,0 0, ,6 10 0,41 4,1 1,95 1,2 6,5 0, ,0 NV = nominal value HV = highest value LV = lowest value SV = standard value August 2001 Copyright 2001 Nexans 49 Nexans Deutschland Industries - Industrial Applications Sieboldstraße Nürnberg - Germany Tel.: +49 (0) 911/ Fax: +49 (0)911/

51 EVA-LL Heat resistant EVA-insulated wires, double insulated Type Approval Certificates VDE-Reg.-No. 9288, approved up to +120 C Applications For internal wiring in dry locations only. For fixed installations elsewhere e.g. visible or embedded conduits or tubes. 300/300 V Max permissible temperature: C Design 1. Conductor Solid copper wire tinned class 1 acc. to DIN VDE Insulation Heat resistant rubbercompound EI3 acc. to DIN VDE 0207, part 20 Marking X NEXANS X VDE-REG.-NR Core identification Colour code acc. to DIN VDE 0293 Cl Br Fl - 25 C/+ 120 C no good good yes 50

52 EVA-LL Technical data Nominal Diameter Conductor Wall Mean Minimum Weight Copper cross-sectional of resistance thickness overall insulation content area of conductor at 20 C insulation diameter resistance conductor at 120 C NV SV max. NV SV LV SV SV mm 2 mm Ω/km mm mm MΩ km kg/km kg/km 0,5 0,8 36,7 2 x 0,6 3,2 0, ,8 0,75 1,0 24,8 2 x 0,6 3,4 0, ,2 1 1,2 18,2 2 x 0,6 3,6 0, ,6 1,5 1,4 7,56 2 x 0,6 3,8 0, ,4 NV = nominal value LV = lowest value SV = standard value August 2001 Copyright 2001 Nexans 51 Nexans Deutschland Industries - Industrial Applications Sieboldstraße Nürnberg - Germany Tel.: +49 (0) 911/ Fax: +49 (0)911/

53 EVA-LL Heat resistant EVA-insulated wires, double insulated Type Approval Certificates VDE-Reg.-No. 9535, approved up to C Applications For internal wiring in dry locations only. For fixed installations elsewhere e.g. visible or embedded conduits or tubes. 300/500 V Max permissible temperature: C Design 1. Conductor Solid copper wire tinned class 1 acc. to DIN VDE Insulation Heat resistant rubbercompound EI3 acc. to DIN VDE 0207, part 20 Marking X NEXANS X VDE-REG.-NR Core identification Colour code acc. to DIN VDE 0293 Cl Br Fl - 25 C/+ 120 C no good good yes 52

54 EVA-LL Technical data Nominal Diameter Conductor Wall Mean Minimum Weight Copper cross-sectional of resistance thickness overall insulation content area of conductor at 20 C insulation diameter resistance conductor at 120 C NV SV max. NV SV LV SV SV mm 2 mm Ω/km mm mm MΩ km kg/km kg/km 0,5 0,8 36,7 2 x 0,7 3,6 0, ,8 0,75 1,0 24,8 2 x 0,7 3,8 0, ,2 1 1,2 18,2 2 x 0,7 5,0 0, ,6 1,5 1,4 7,56 2 x 0,7 5,2 0, ,4 NV = nominal value LV = lowest value SV = standard value August 2001 Copyright 2001 Nexans 53 Nexans Deutschland Industries - Industrial Applications Sieboldstraße Nürnberg - Germany Tel.: +49 (0) 911/ Fax: +49 (0)911/

55 EVA-LLF Heat resistant EVA-insulated wires, double insulated Type Approval Certificates VDE-Reg.-No Applications For internal wiring in dry locations only. For fixed installations elsewhere e.g. visible or embedded conduits or tubes. 300/300 V Max permissible temperature: C Design 1. Conductor Flexible copper wires tinned, class 5 acc. to DIN VDE Insulation Heat resistant rubbercompound EI3 acc. to DIN VDE 0207, part 20 Marking X NEXANS X VDE-REG.-NR Core identification Colour code acc. to DIN VDE 0293 Cl Br Fl - 25 C/+ 120 C yes good good yes 54

56 EVA-LLF Technical data Nominal Diameter Diameter Conductor Wall Mean Minimum Weight Copper cross- of single of resistance thickness overall insulation content sectional wires of the conductor at 20 C insulation diameter resistance area of conductor at 110 C conductor NV HV SV max. NV SV LV SV SV mm 2 mm mm Ω/km mm mm MΩ km kg/km kg/km 0,5 0,21 0,9 40,1 2 x 0,6 3,3 0, ,8 0,75 0,21 1,1 26,7 2 x 0,6 3,5 0, ,2 1 0,21 1,3 20,0 2 x 0,6 3,7 0, ,6 1,5 0,26 1,6 13,7 2 x 0,6 4,0 0, ,4 NV = nominal value HV = highest value LV = lowest value SV = standard value August 2001 Copyright 2001 Nexans 55 Nexans Deutschland Industries - Industrial Applications Sieboldstraße Nürnberg - Germany Tel.: +49 (0) 911/ Fax: +49 (0)911/

57 DE-N07G-U Cable with increased heat resistance for internal wiring Type Approval Certificates VDE-Reg.-No Application Designed for internal wiring (lightings,appliances, electrical machines) at ambient temperatures over 55 C; especially where the max. temperature of the harmonized cables H07G-U/ H07G-K is exceeded. 450/750 V Max permissible temperature: C Design 1. Conductor Solid copper wire tinned class 1 acc. to DIN VDE Insulation Heat resistant rubbercompound 4GI010 acc. to DIN VDE 0282 Marking X NEXANS X VDE-REG.-NR DE-N07G-U Core identification Colour code acc. to DIN VDE 0293, earth-wire green-yellow Cl Br Fl - 25 C/+ 120 C no good good yes 56

58 DE-N07G-U Technical data Nominal Diameter Conductor Wall Mean Minimum Weight Copper cross-sectional of resistance thickness overall insulation content area of conductor at 20 C insulation diameter resistance conductor at 120 C NV SV max. NV SV LV SV SV mm 2 mm Ω/km mm mm MΩ km kg/km kg/km 0,5 0,80 36,7 0,8 2,4 0, ,8 0,75 1,00 24,8 0,8 2,6 0, ,2 1 1,15 18,2 0,8 2,7 0, ,6 1,5 1,40 12,2 0,8 3,0 0, ,4 2,5 1,80 7,56 0,9 3,7 0, ,0 4 2,20 4,7 1,0 4,2 0, ,4 NV = nominal value LV = lowest value SV = standard value August 2001 Copyright 2001 Nexans 57 Nexans Deutschland Industries - Industrial Applications Sieboldstraße Nürnberg - Germany Tel.: +49 (0) 911/ Fax: +49 (0)911/

59 DE-N07G-K Cable with increased heat resistance for internal wiring Type Approval Certificates VDE-Reg.-No Application Designed for internal wiring (lightings,appliances, electrical machines) at ambient temperatures over 55 C; especially where the max. temperature of the harmonized cables H07G-U/ H07G-K is exceeded. 450/750 V Max permissible temperature: C Design 1. Conductor Flexible copper wires tinned, class 5 acc. to DIN VDE Insulation Heat resistant rubbercompound 4GI010 acc. to DIN VDE 0282 Marking X NEXANS X VDE-REG.-NR DE-N07G-K Core identification Colour code acc. to DIN VDE 0293, earth-wire green-yellow Cl Br Fl - 25 C/+ 120 C yes good good yes 58

60 DE-N07G-K Technical data Nominal Diameter Diameter Conductor Wall Mean Minimum Weight Copper cross- of single of resistance thickness overall insulation content sectional wires of the conductor at 20 C insulation diameter resistance area of conductor at 110 C conductor NV HV SV max. NV SV LV SV SV mm 2 mm mm Ω/km mm mm MΩ km kg/km kg/km 0,5 0,21 0,9 40,1 0,8 2,5 0, ,8 0,75 0,21 1,1 26,7 0,8 2,7 0, ,2 1 0,21 1,3 20,0 0,8 2,9 0, ,6 1,5 0,26 1,5 13,7 0,8 3,2 0, ,4 2,5 0,26 2,0 8,21 0,9 4,0 0, ,0 4 0,31 2,5 5,09 1,0 4,6 0, ,4 6 0,31 3,0 3,39 1,0 5,0 0, ,6 10 0,41 4,1 1,95 1,2 6,5 0, ,0 NV = nominal value HV = highest value LV = lowest value SV = standard value August 2001 Copyright 2001 Nexans 59 Nexans Deutschland Industries - Industrial Applications Sieboldstraße Nürnberg - Germany Tel.: +49 (0) 911/ Fax: +49 (0)911/

61 S07H-U Halogen free and flame resistant single-core cable Type Approval Certificates VDE-Reg.-Nr Applications For internal wiring of appliances and for protected laying in and on luminaries. Suitable for installation in surface mounted or embedded conduits only for signalling circuits. 450/750 V Max permissible temperature: + 70 C Design 1. Conductor Solid copper wire class 1 acc. to DIN VDE Insulation Compound of polyolefine, halogen free, flame restistant Marking X NEXANS X VDE-REG.-NR S07H(HFFR) Core identification Colour code acc. to DIN VDE 0293 Cl Br Fl +5 C/+70 C good no yes yes yes yes yes yes 60

62 S07H-U Technical data Nominal Diameter Conductor Wall Mean Minimum Weight Copper cross-sectional of resistance thickness overall insulation content area of conductor at 20 C insulation diameter resistance conductor at 70 C NV SV max. NV SV LV SV SV mm 2 mm Ω/km mm mm MΩ km kg/km kg/km 1,5 1,4 12,1 0,7 2,9 0, ,4 2,5 1,8 7,41 0,8 3,4 0, ,0 4 2,3 4,61 0,8 4,1 0, ,4 NV = nominal value LV = lowest value SV = standard value August 2001 Copyright 2001 Nexans 61 Nexans Deutschland Industries - Industrial Applications Sieboldstraße Nürnberg - Germany Tel.: +49 (0) 911/ Fax: +49 (0)911/

63 S07H-K Halogen free and flame resistant single-core cable Type Approval Certificates VDE-Reg.-Nr Applications For internal wiring of appliances and for protected laying in and on luminaries. Suitable for installation in surface mounted or embedded conduits only for signalling circuits. 450/750 V Max permissible temperature: + 70 C Design 1. Conductor Flexible copper class 5 acc. to DIN VDE Insulation Compound of polyolefine, halogen free, flame restistant Marking X NEXANS X VDE-REG.-NR S07H(HFFR) Core identification Colour code acc. to DIN VDE 0293 Cl Br Fl +5 C/+70 C good yes yes yes yes yes yes yes 62

64 S07H-K Technical data Nominal Diameter Diameter Conductor Wall Mean Minimum Weight Copper cross- of single of resistance thickness overall insulation content sectional wires of the conductor at 20 C insulation diameter resistance area of conductor at 70 C conductor NV HV SV max. NV SV LV SV SV mm 2 mm mm Ω/km mm mm MΩ km kg/km kg/km 1,5 0,26 1,6 13,3 0,7 3,0 0, ,4 2,5 0,26 2,1 7,98 0,8 3,6 0, ,0 4 0,31 2,6 4,95 0,8 4,2 0, ,4 NV = nominal value HV = highest value LV = lowest value SV = standard value August 2001 Copyright 2001 Nexans 63 Nexans Deutschland Industries - Industrial Applications Sieboldstraße Nürnberg - Germany Tel.: +49 (0) 911/ Fax: +49 (0)911/

65 S07H-U (HFFR, 90 ) Halogen free, flame retardant and heat resistant core cable Type Approval Certificates VDE-Reg.-Nr Applications For internal wiring of appliances e.g. in or on luminaries. Must not get in touch with hot parts of more than 90 C. Can be used the same way as the heat resistant cores H05V2/ H07V2 acc. to DIN VDE 0281, part /750 V Max permissible temperature: + 90 C Design 1. Conductor Solid copper wire class 1 acc. to DIN VDE Insulation Compound of polyolefine, halogen free, flame restistant, heat resistant Marking X NEXANS X VDE-REG.-NR S07H (HFFR 90 C) Core identification Colour code acc. to DIN VDE 0293 Cl Br Fl +5 C/+90 C good no yes yes yes yes yes yes 64

66 S07H-U (HFFR, 90 ) Technical data Nominal Diameter Conductor Wall Mean Minimum Weight Copper cross-sectional of resistance thickness overall insulation content area of conductor at 20 C insulation diameter resistance conductor at 90 C NV SV max. NV SV LV SV SV mm 2 mm Ω/km mm mm MΩ km kg/km kg/km 1,5 1,4 12,1 0,7 3,0 0, ,4 2,5 1,8 7,41 0,8 3,4 0, ,0 NV = nominal value LV = lowest value SV = standard value August 2001 Copyright 2001 Nexans 65 Nexans Deutschland Industries - Industrial Applications Sieboldstraße Nürnberg - Germany Tel.: +49 (0) 911/ Fax: +49 (0)911/

67 S07H-K (HFFR, 90 ) Halogen free, flame retardant and heat resistant core cable Type Approval Certificates VDE-Reg.-Nr Applications For internal wiring of appliances e.g. in or on luminaries. Must not get in touch with hot parts of more than 90 C. Can be used the same way as the heat resistant cores H05V2/ H07V2 acc. to DIN VDE 0281, part /750 V Max permissible temperature: + 90 C Design 1. Conductor Flexible copper class 5 acc. to DIN VDE Insulation Compound of polyolefine, halogen free, flame restistant, heat resistant Marking X NEXANS X VDE-REG.-NR S07H (HFFR 90 C) Core identification Colour code acc. to DIN VDE 0293 Cl Br Fl +5 C/+90 C good yes yes yes yes yes yes yes 66

68 S07H-K (HFFR, 90 ) Technical data Nominal Diameter Diameter Conductor Wall Mean Minimum Weight Copper cross- of single of resistance thickness overall insulation content sectional wires of the conductor at 20 C insulation diameter resistance area of conductor at 90 C conductor NV HV SV max. NV SV LV SV SV mm 2 mm mm Ω/km mm mm MΩ km kg/km kg/km 1,5 0,26 1,6 13,3 0,7 3,0 0, ,4 2,5 0,26 2,1 7,98 0,8 3,6 0, ,0 4 0,31 2,6 4,95 0,8 4,2 0, ,4 6 0,31 3,2 3,30 0,8 4,7 0, ,6 NV = nominal value HV = highest value LV = lowest value SV = standard value August 2001 Copyright 2001 Nexans 67 Nexans Deutschland Industries - Industrial Applications Sieboldstraße Nürnberg - Germany Tel.: +49 (0) 911/ Fax: +49 (0)911/

69 S07H-R (HFFR, 90 ) Halogen free, flame retardant and heat resistant core cable Type Approval Certificates VDE-Reg.-Nr Applications For internal wiring of appliances e.g. in or on luminaries. Must not get in touch with hot parts of more than 90 C. Can be used the same way as the heat resistant cores H05V2/ H07V2 acc. to DIN VDE 0281, part /750 V Max permissible temperature: + 90 C Design 1. Conductor Stranded copper class 2 acc. to DIN VDE Insulation Compound of polyolefine, halogen free, flame restistant, heat resistant Marking X NEXANS X VDE-REG.-NR S07H (HFFR 90 C) Core identification Colour code acc. to DIN VDE 0293 Cl Br Fl +5 C/+90 C good no yes yes yes yes yes yes 68

International Power Supply Cords

International Power Supply Cords Our Online Product Catalogs Electri-Cord Manufacturing Co. Westfield, PA ~ Since 1946 ~ International Power Supply Cords Most of the cords shown in this brochure are standard, stock items at our factory

More information

20 HUBER+SUHNER RADOX SOLAR

20 HUBER+SUHNER RADOX SOLAR All our cables fully comply with the European directives 76/769/EWG, 2003/11/EG, 2000/53/EG, 2003/53/EG and 2002/95/EG (RoHS) and the requirements of REACH Nr. EC1907/2006. 20 RADOX SOLAR cables RADOX

More information

RHEYFIRM (RTS) R-(N)TSCGEWTOEUS 3x...+3x.../3 3.6/6 kv 20/35 kv adapted to DIN VDE 0250 part 813

RHEYFIRM (RTS) R-(N)TSCGEWTOEUS 3x...+3x.../3 3.6/6 kv 20/35 kv adapted to DIN VDE 0250 part 813 REELING CABLE RHEYFIRM (RTS) R-(N)TSCGEWTOEUS 3x...+3x.../3 3.6/6 kv 20/35 kv adapted to DIN VDE 0250 part 813 Contents: Letter code Construction details and voltage-classes Technical data 2016 RHEYFIRM(RTS)

More information

Single terminal blocks

Single terminal blocks 87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 - Fax: +33 5 55 06 88 88 R Single terminal blocks CONTENTS 1. General characteristics...1 2. Materials...2 3. Range...3 4. Performance...3 5. Dimensions...4

More information

ÖLFLEX CLASSIC 110 H Info Benefits

ÖLFLEX CLASSIC 110 H Info Benefits Halogen-free control cable, oil resistant and very flexible - halogen-free control cable, HFFR, oil-resistant, very flexible and cold-resistant down to -30 C for various applications, CPR Info CPR: Article

More information

H05BQ-F / H07BQ-F. The harmonized PUR cable with Europe wide registration according to HD S1 VDE Description.

H05BQ-F / H07BQ-F. The harmonized PUR cable with Europe wide registration according to HD S1 VDE Description. H05BQ-F, H07BQ-F The harmonized PUR cable with Europe wide registration according to HD 22.10 S1 VDE 0282 Description Application In dry, damp or wet areas for medium duty; e. g. for connection of industrial

More information

VDE-registered oil-resistant PVC control cable with black outer sheath for a wide range of applications

VDE-registered oil-resistant PVC control cable with black outer sheath for a wide range of applications VDE-registered oil-resistant PVC control cable with black outer sheath for a wide range of applications - PVC control cable, VDE registered, oil resistant, flexible and UV-resistant for various applications,

More information

Conductor: plain wire, fine stranding as per VDE 0295 class 6 from 50 mm² fine stranding according to VDE 0295 class 5

Conductor: plain wire, fine stranding as per VDE 0295 class 6 from 50 mm² fine stranding according to VDE 0295 class 5 Semoflex DRUM Description Application In dry and damp rooms, explosive security areas and also outdoors for heavy-duty units such as hoisting gears, transportation systems, motorized cable reels, rail

More information

SPECIFICATION S VR 1(4) HALOGEN FREE POWER AND CONTROL CABLE FOR MARINE APPLICATIONS LM-HF 0,6/1 kv and TEMAR PHFX-U 0,6/1 kv APPLICATI

SPECIFICATION S VR 1(4) HALOGEN FREE POWER AND CONTROL CABLE FOR MARINE APPLICATIONS LM-HF 0,6/1 kv and TEMAR PHFX-U 0,6/1 kv APPLICATI 1(4) HALOGEN FREE POWER AND CONTROL CABLE FOR MARINE APPLICATIONS LM-HF 0,6/1 kv and TEMAR PHFX-U 0,6/1 kv APPLICATION Power and control cable for fixed installations. Designed to fulfill requirements

More information

Cable systems We offer you the essential components for a future-oriented e-mobility.

Cable systems We offer you the essential components for a future-oriented e-mobility. Range We are working for you worldwide. Cable systems We offer you the essential components for a future-oriented e-mobility. Individual items We start with your ideas, so you can make your vision of intelligent

More information

BX3-SSU INSTRUCTIONS SCANNING STAGE WITH ULTRASONIC

BX3-SSU INSTRUCTIONS SCANNING STAGE WITH ULTRASONIC INSTRUCTIONS BX3-SSU SCANNING STAGE WITH ULTRASONIC This instruction manual is for the Olympus Scanning Stage with Ultrasonic Model BX3-SSU. To ensure the safety, obtain optimum performance and to familiarize

More information

PRODUCT INFORMATION ÖLFLEX HEAT 125 C MC. Info Improved characteristics in the event of a fire GL - Germanischer Lloyd approved

PRODUCT INFORMATION ÖLFLEX HEAT 125 C MC. Info Improved characteristics in the event of a fire GL - Germanischer Lloyd approved Electron beam cross-linked cables for more demanding application requirements - halogen free shielded control cable with GL certificate, special fire performance, IEC 60332-3, suitable for +125 C Info

More information

Approvals (Norm references)

Approvals (Norm references) ÖLFLEX ROBUST 200 Robust and weatherproofed Wide range of application opportunities Machine tool manufacture, medical technology, laundries, car washing equipment, chemical industry, composting plants,

More information

ÖLFLEX CLASSIC 135 CH -halogen-free control cable, HFFR, flexible and screened for various applications, U 0 /U: 300/500V

ÖLFLEX CLASSIC 135 CH -halogen-free control cable, HFFR, flexible and screened for various applications, U 0 /U: 300/500V PRODUCT INFORMATION Screened halogen-free control cable with improved fire characteristics -halogen-free control cable, HFFR, flexible and screened for various applications, U 0 /U: 300/500V Info CPR:

More information

H05 V-K PVC-Single Cores, fine wire stranded

H05 V-K PVC-Single Cores, fine wire stranded H05 VK PVCSingle Cores, fine wire stranded Technical data PVC single cores to DINVDE0283 H05 VK/H05 VU to DINVDE028 part3, HD2.3S3 and IEC02273 Temperature range flexing 5 C to +70 C fixed installation

More information

ENERGY. TECSUN(PV) PV1-F Cables for Photovoltaics

ENERGY. TECSUN(PV) PV1-F Cables for Photovoltaics ENERGY TECSUN(PV) PV1-F Cables for Photovoltaics Technical Data Manufacturer Trademark Type designation Prysmian Kabel und Systeme GmbH Kabelwerk Neustadt bei Coburg / Germany TECSUN (PV) PV1-F Approvals

More information

sa B-CABLES nv PROTOLON(ST) NTSCGEWOEU Medium Voltage Flexible Cables for Use In Water sa B-CABLES nv ENERGY

sa B-CABLES nv PROTOLON(ST) NTSCGEWOEU Medium Voltage Flexible Cables for Use In Water sa B-CABLES nv ENERGY PROTOLON(ST) NTSCGEWOEU Medium Voltage Flexible Cables for Use In Water ENERGY Technical Data Electrical Thermal Type Type designation PROTOLON(ST) NTSCGEWÖU Approvals/ standards DIN VDE 0250 part 813

More information

Power & Control Cable IEC

Power & Control Cable IEC (2-, 3-, 4,- and 5-cores) U 0 Application For electricity supply and control in public networks and industrial plants; suitable for use in zone 1 and zone 2 group ΙΙ classified areas (IEC 60079-14). Recoended

More information

sa B-CABLES nv PROTOLON(ST) NTSCGEWOEU.../3E Medium Voltage Flexible Cables for Use in Water with Copper Core Shield sa B-CABLES nv ENERGY

sa B-CABLES nv PROTOLON(ST) NTSCGEWOEU.../3E Medium Voltage Flexible Cables for Use in Water with Copper Core Shield sa B-CABLES nv ENERGY PROTOLON(ST) NTSCGEWOEU.../3E Medium Voltage Flexible Cables for Use in Water with Copper Core Shield ENERGY Technical Data Electrical Thermal Type Type designation PROTOLON (ST) NTSCGECEWÖU.../3E Approvals/

More information

VDE tested single cores according to EN (H05Z-K & H07Z-K) for more demanding requirements

VDE tested single cores according to EN (H05Z-K & H07Z-K) for more demanding requirements VDE tested single cores according to EN 50525-3-41 (H05Z-K & H07Z-K) for more demanding requirements ÖLFLEX HEAT 125 C MC - halogen free single core with GL certificate, special fire performance, IEC 60332-3,

More information

This document is a preview generated by EVS

This document is a preview generated by EVS TECHNICAL SPECIFICATION CLC/TS 50457-1 SPÉCIFICATION TECHNIQUE TECHNISCHE SPEZIFIKATION March 2008 ICS 43.120 Supersedes ENV 50275-2-3:1998 English version Conductive charging for electric vehicles - Part

More information

ÖLFLEX CLASSIC 130 H - halogen-free control cable, HFFR and flexible for various applications, U 0 /U: 300/500V

ÖLFLEX CLASSIC 130 H - halogen-free control cable, HFFR and flexible for various applications, U 0 /U: 300/500V Halogen-free control cable with improved fire characteristics - halogen-free control cable, HFFR and flexible for various applications, U 0 /U: 300/500V Info CPR: choice under www.lappkabel.com/cpr For

More information

Selection table for heat-resistant cables

Selection table for heat-resistant cables Just click on the products in the selection table. Click on the HELUKABEL logo at the end of the page to go back. Cables & Wires Selection table for heat-resistant cables www.helukabel.com HEAT-RESISTANT

More information

ENERGY. Solar Cables

ENERGY. Solar Cables ENERGY Solar Cables Contents TECSUN(PV) PV1-F Cables for Photovoltaics 3 Technical Data 4 Design Features 6 Selection and Ordering Data 6 TECSUN DUO (PV) Cables for Photovoltaics 7 Technical Data 8 Design

More information

Global data. Electrical parameters

Global data. Electrical parameters ()TSCGEWOEU TEAX TTS 3,6/6 kv: Application Flexible medium voltage reeling cable for application under high mechanical stresses, e.g. high travel speeds, dynamic loads, multiple changes of direction into

More information

ÖLFLEX CLASSIC 110 CY

ÖLFLEX CLASSIC 110 CY Screened PVC control cable with transparent outer sheath - PVC control cable, VDE registered, screened, flexible and numbered for various applications, U 0 /U: 300/500V Info CPR: choice under www.lappkabel.com/cpr

More information

Mains Flex Oval/Round 2-3 Core

Mains Flex Oval/Round 2-3 Core 2 Core 3 Core Features: Flexible mains cable for internal use in the direct connection of equipment to mains power supplies. PVC insulated and sheathed flexible mains cords. Standard core colours : Brown

More information

is the UK subsidary of Tele-Fonika Kable S.A., with offices and a warehouse centrally located in Leicestershire.

is the UK subsidary of Tele-Fonika Kable S.A., with offices and a warehouse centrally located in Leicestershire. is the UK subsidary of Tele-Fonika Kable S.A., with offices and a warehouse centrally located in Leicestershire. We are a major supplier of housewiring, low voltage, power and fire resistant cables for

More information

ENERGY. TECSUN(PV) PV1 F Cables for Photovoltaics

ENERGY. TECSUN(PV) PV1 F Cables for Photovoltaics ENERGY TECSUN(PV) PV1 F Cables for Photovoltaics Technical Data Electrical Thermal Manufacturer Trademark Type designation Prysmian Kabel und Systeme GmbH Kabelwerk Neustadt bei Coburg / DE TECSUN (PV)

More information

Industry Cables Special cables for industrial applications General Catalogue

Industry Cables Special cables for industrial applications General Catalogue Industry Cables Special cables for industrial applications General Catalogue Industry Cables Special cables for industrial applications General catalogue Linking the Future As the worldwide leader in the

More information

Any inquiries, please feel free to contact or Caledonian

Any inquiries, please feel free to contact or Caledonian Caledonian Low Voltage cables to IEC 60502 Standard www.caledonian-cables.co.uk www.caledonian-cables.net 1 Addison Company Profile Caledonian. established in 1978.offers one of the most complete lines

More information

Cables for Railway Technology

Cables for Railway Technology Cables for Railway Technology www.sab-worldwide.com Content q In case that you don t find a suitable cable for your special application, we are always prepared to design a cable according to your individual

More information

HYDROFIRM(T) S1BB-F and S1BBH2-F 0,6/1 kv. Round and Flat Cables for Drinking Water Application KTW/DVGW W270/ACS/WRAS ENERGY

HYDROFIRM(T) S1BB-F and S1BBH2-F 0,6/1 kv. Round and Flat Cables for Drinking Water Application KTW/DVGW W270/ACS/WRAS ENERGY HYDROFIRM(T) S1BB-F and S1BBH2-F 0,6/1 kv Round and Flat Cables for Drinking Water Application KTW/DVGW W270/ACS/WRAS ENERGY Technical Data Electrical Thermal Trademark Type designation Specification Application

More information

300 V TTR KABLOLAR 300 V MULTICORE CABLES H03VV-F H03V2V2-F H03V2V2-F 105 C H03VVH2-F H03V2V2H2-F H03V2V2H2-F 105 C TS 9760 HD 21.5 S3 - VDE 0281-5 HD 21.5 S3 TS HD 21.12 S1 - VDE 0281-12 HD 21.12 S1 TS

More information

PROTOLON(FL)-LWL (N)TSFLCGEWOEU 3,6/6 kv: medium voltage flat reeling cable with fibre-optics

PROTOLON(FL)-LWL (N)TSFLCGEWOEU 3,6/6 kv: medium voltage flat reeling cable with fibre-optics PROTOLON(FL)-LWL (N)TSFLCGEWOEU 3,6/6 kv: medium voltage flat reeling cable with Application Flexible medium voltage reeling cable for high mechanical stresses (e.g. dynamic tensile loads, multiple changes

More information

MOTOR, SERVO, & FEEDBACK CABLES

MOTOR, SERVO, & FEEDBACK CABLES MOTOR, SERVO, & FEEDBACK CABLES Motor, servo, and feedback cables Temperature ( C) - flexing Temperature ( C) - fixed Nominal voltage U 0 /U Bending radius - flexing x Ø Bending radius - fixed x Ø Halogen-free

More information

PUR c-track cables For highest requirements

PUR c-track cables For highest requirements 2. C-track cables PUR c-track cables For highest requirements LÜTZE SUPERFLEX PLUS N PUR UL 300 V Machine and device construction, transport and conveyor technology Through full PUR jacket and TPE conductor

More information

This document is a preview generated by EVS

This document is a preview generated by EVS EESTI STANDARD EVS-EN 12806:2003 Automotive liquefied petroleum gas components - Other than containers Automotive liquefied petroleum gas components - Other than containers EESTI STANDARDIKESKUS EESTI

More information

COLD ROLLED STEEL SECTIONS -

COLD ROLLED STEEL SECTIONS - STANDARD I.S. EN 10162:2003 ICS 77.140.70 National Standards Authority of Ireland Dublin 9 Ireland COLD ROLLED STEEL SECTIONS - Tel: (01) 807 3800 Fax: (01) 807 3838 TECHNICAL DELIVERY CONDITIONS - DIMENSIONAL

More information

ÖLFLEX CLASSIC 115 CY

ÖLFLEX CLASSIC 115 CY Screened PVC control cable with small outer diameter - PVC control cable, screened and flexible for various applications, thin and light without inner sheath, U 0 /U: 300/500V Info CPR: choice under www.lappkabel.com/cpr

More information

PROTOLON (SB) PROTOLON (SB) with Copper Core Shield Flexible Cables for Trailing Operation

PROTOLON (SB) PROTOLON (SB) with Copper Core Shield Flexible Cables for Trailing Operation PROTOLON (SB) PROTOLON (SB) with Copper Core Shield Flexible Cables for Trailing Operation 2 17 BUIS_003.tif 2 18 BUIS_004.tif Selection and dimensioning criteria Refer to Section 4 for further details

More information

Data sheet chainflex CF8821

Data sheet chainflex CF8821 1. Outer jacket: Pressure extruded, oil-resistant PVC mixture 2. Overall shield: Braiding made of tinned copper wires 3. Overall banding: Plastic foil 4. Core insulation: Mechanically high-quality TPE

More information

Power & Control Cable IEC

Power & Control Cable IEC (2-, 3-, and 4-cores) U 0 Application For electricity supply and control in public networks and industrial plants; suitable for use in zone 1 and zone 2 group ΙΙ classified areas (IEC 60079-14). Recoended

More information

Power & Control Cables. U o. /U 0.6/1 kv - IEC

Power & Control Cables. U o. /U 0.6/1 kv - IEC Power & Control Cables U o /U 0.6/1 kv - IEC 60502-1 2 KERPEN GmbH & Co. KG 07.2005 Printing errors excepted. Subject to alteration List of Contents Introduction Page B1 Construction Page B3 Use Page B4

More information

Cable category. B Multi-core cables for domestic/handheld equipment Rubber insulation PVC insulation TPE insulation 0.

Cable category. B Multi-core cables for domestic/handheld equipment Rubber insulation PVC insulation TPE insulation 0. Table 12-1: current rating Technical Tables T12 Current ratings basic table ÖLFLEX For cables with a nominal voltage of up to 1000 V and for heat-resistant cables at an ambient temperature of +30 C. You

More information

CORDAFLEX(SMK) (N)SHTÖU Tough Rubber-Sheathed Reeling Cables

CORDAFLEX(SMK) (N)SHTÖU Tough Rubber-Sheathed Reeling Cables CORDAFLEX(SMK) (N)SHTÖU Tough Rubber-Sheathed Reeling Cables 3 SK1_1-001.tif 4 SK1_1-003.tif SK1_1-00.tif Selection and dimensioning criteria Refer to Section 4 for further details Ü Type CORDAFLEX(SMK)

More information

Submarine Power Cables

Submarine Power Cables Submarine Power Cables Submarine Power Cables Since decades Nexans plant in Hannover is specialised in the design, production and installation of low and medium voltage submarine power cables required

More information

INDUSTRIAL SOLUTIONS MARINE CATALOGUE INNOVATIVE CABLE SOLUTIONS MEETING INTERNATIONAL STANDARDS

INDUSTRIAL SOLUTIONS MARINE CATALOGUE INNOVATIVE CABLE SOLUTIONS MEETING INTERNATIONAL STANDARDS INDUSTRIAL SOLUTIONS MARINE CATALOGUE INNOVATIVE CABLE SOLUTIONS MEETING INTERNATIONAL STANDARDS TKF TECHNOLOGICAL LEADERSHIP IN CONNECTIVITY SOLUTIONS Since its establishment in 1930 TKF developed from

More information

RADOX. Coil winding industry. Edition 2014

RADOX. Coil winding industry. Edition 2014 RADOX Coil winding industry Edition 2014 RADOX for the toughest condition Your partner for connectivity solutions Your partner for connectivity solutions HUBER+SUHNER is a leading global supplier of components

More information

SPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING S ULTRA CONTINUOUSLY FLEXIBLE WITH HIGHEST FIRE PROTECTION

SPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING S ULTRA CONTINUOUSLY FLEXIBLE WITH HIGHEST FIRE PROTECTION SPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING S ULTRA CONTINUOUSLY FLEXIBLE WITH HIGHEST FIRE PROTECTION fire protection halogen-free flexibility oil resistance These are the characteristics united

More information

Power & Control Cable IEC

Power & Control Cable IEC (2-, 3-, and 4-cores) U 0 PVC-Insulation, Application For electricity supply and control in public networks and industrial plants; suitable for use in zone 1 and zone 2 group ΙΙ classified areas (IEC 60079-14).

More information

INFORMATION. Hybrid cables. Description

INFORMATION. Hybrid cables. Description Description INFORMATION This chapter shows the technical data of the hybrid cables available at SEW EURODRIVE. For assignment of hybrid cables to the products, refer to the respective chapters..1 Description

More information

THE UK S BENCHMARK FOR TRI-RATED CABLE

THE UK S BENCHMARK FOR TRI-RATED CABLE THE UK S BENCHMARK FOR TRI-RATED CABLE Welcome to Clynder Cables Clynder Cables has over thirty years of experience in the supply of UK manufactured industrial electrical cables to the UK, European and

More information

Data sheet chainflex CF210.UL

Data sheet chainflex CF210.UL For detailed overview please see design table 1. Outer jacket: Pressure extruded, oil-resistant PVC mixture 2. Overall shield: Bending-resistant braiding made of tinned copper wires. 3. Banding: Plastic

More information

ENERGY. HYDROFIRM(T) EMV-FC S1BC4B-F 0,6/1 kv. Screened Cable for Drinking Water Application KTW/ACS

ENERGY. HYDROFIRM(T) EMV-FC S1BC4B-F 0,6/1 kv. Screened Cable for Drinking Water Application KTW/ACS ENERGY HYDROFIRM(T) EMV-FC S1BC4B-F 0,6/1 kv Screened Cable for Drinking Water Application KTW/ACS Technical Data Trademark Type designation Specification Application HYDROFIRM(T) EMV-FC S1BC4B-F Design

More information

WATER-TUBE BOILERS AND AUXILIARY

WATER-TUBE BOILERS AND AUXILIARY IRISH STANDARD I.S. EN 12952-12:2003 ICS 13.060.25 27.040 WATER-TUBE BOILERS AND AUXILIARY National Standards Authority of Ireland Dublin 9 Ireland Tel: (01) 807 3800 Tel: (01) 807 3838 INSTALLATIONS -

More information

INDEX PRODUCT RANGE TRATOSFLEX- NSHTÖU-JZ TRATOSFLEX- NSHTÖU-JZK TRATOSFLEX - NSHTÖU-J TRATOSFLEX- NSHTÖU-JK TRATOSFLEX-OCS NEW TRATOSFLEX-ES *

INDEX PRODUCT RANGE TRATOSFLEX- NSHTÖU-JZ TRATOSFLEX- NSHTÖU-JZK TRATOSFLEX - NSHTÖU-J TRATOSFLEX- NSHTÖU-JK TRATOSFLEX-OCS NEW TRATOSFLEX-ES * october 2004 TRATOSFLEX 2 Selection of type of cable in relation to use Recommended Bending Radius INDEX Current carrying capacities for continuos operation Current carrying capacities for intermittent

More information

Eurocode 2 Design of concrete structures

Eurocode 2 Design of concrete structures BRITISH STANDARD BS EN 1992-3:2006 Eurocode 2 Design of concrete structures Part 3: Liquid retaining and containment structures The European Standard EN 1992-3:2006 has the status of a British Standard

More information

This document is a preview generated by EVS

This document is a preview generated by EVS TECHNICAL SPECIFICATION CLC/TS 50591 SPÉCIFICATION TECHNIQUE TECHNISCHE SPEZIFIKATION November 2013 ICS 45.060.10 English version Specification and verification of energy consumption for railway rolling

More information

TRIFLEX H07RN-F CPR COMPLIANT REGULATION 305/2011/EU. Low voltage - Energy, cabling, signalling and control. reaction to fire

TRIFLEX H07RN-F CPR COMPLIANT REGULATION 305/2011/EU. Low voltage - Energy, cabling, signalling and control. reaction to fire Low voltage - Energy, cabling, signalling and control TRIFLEX H07RN-F Structure and, physical, mechanical requirements: Low Directive: RoHS Directive: EN 50525-2-21 2014/35/EU 2011/65/EU Standard: Class:

More information

H07RN-F TITANEX (industrial flexible)

H07RN-F TITANEX (industrial flexible) Description Application TITANEX flexible cable is intended for installations with moving equipment, electric appliances and for building sites. The cable may be rated 0,6/1 kv where the installation has

More information

This document is a preview generated by EVS

This document is a preview generated by EVS CEN WORKSHOP CWA 15375 August 2005 AGREEMENT ICS 47.020.30 English version Separators for marine residual fuel - Performance testing using specific test oil This CEN Workshop Agreement has been drafted

More information

Data sheet chainflex CF240

Data sheet chainflex CF240 1. Outer jacket: Pressure extruded, oil-resistant PVC mixture 2. Overall shield: Aluminum/Polyester tape and extremely bending-resistant braiding made of tinned copper wires. 3. Banding: Plastic foil 4.

More information

Data sheet chainflex CFSOFT1

Data sheet chainflex CFSOFT1 to 5 x d Highly flexible, soft design PVC outer jacket Oil-resistant Flame retardant 1. Outer jacket: Pressure extruded, oil-resistant PVC mixture 2. Core insulation: Mechanically high-quality TPE mixture

More information

www. h itech controls.com (800) I (303) Click or Call for a Quotel Photo: HELUKABEL Robotic Cables C HELUKABEL

www. h itech controls.com (800) I (303) Click or Call for a Quotel Photo: HELUKABEL Robotic Cables C HELUKABEL Photo: HELUKABEL Robotic Cables Robotic Cables With over 30 years of experience with cables and lines, we also have the right solutions for the demands placed on the components to be installed by the applications

More information

RADOX. for the Coil Winding Industry Edition 2009

RADOX. for the Coil Winding Industry Edition 2009 RADOX for the Coil Winding Industry Edition 2009 RADOX for the toughest conditions 2 HUBER+SUHNER Your partner for connectivity solutions Your partner for connectivity solutions HUBER+SUHNER is a leading

More information

Photo: HELUKABEL. Trailing Cables G 1

Photo: HELUKABEL. Trailing Cables G 1 Photo: HELUKABEL Trailing Cables G 1 Trailing Cables Trailing cables are used for high mechanical stress, especially for applications with frequent winding and unwinding with simultaneous tensile and torsional

More information

ILNAS-EN 15663:2017. Railway applications - Vehicle reference masses. Bahnanwendungen - Fahrzeugreferenzmassen

ILNAS-EN 15663:2017. Railway applications - Vehicle reference masses. Bahnanwendungen - Fahrzeugreferenzmassen Railway applications - Vehicle reference masses Bahnanwendungen - Fahrzeugreferenzmassen Applications ferroviaires - Masses de référence des véhicules 07/2017 National Foreword This European Standard EN

More information

YSHIELD. (N)YM(St)-J - Shielded sheathed cable

YSHIELD. (N)YM(St)-J - Shielded sheathed cable Prices Electro Measurement Grounding Canopies Textile products Fabrics Sheet products Paints (N)YM(St)-J - Shielded sheathed cable Wire count /cross section Outer diameter Weight 3 x 1.5 mm² 10.5 mm 154

More information

DEUTSCHE NORM DIN EN 10080

DEUTSCHE NORM DIN EN 10080 DEUTSCHE NORM DIN EN 10080 August 2005 { ICS 77.140.15; 77.140.60; 77.140.65 Supersedes DIN V ENV 10080, August 1995 edition, parts of DIN 488-1, September 1984 edition, DIN 488-2, DIN 488-4 and DIN 488-6,

More information

Data sheet chainflex CF881

Data sheet chainflex CF881 1. Outer jacket: Pressure extruded PVC mixture 2. Overall shield: Braiding made of tinned copper wires 3. Banding: Plastic foil 4. Core insulation: Mechanically high-quality PVC mixture 5. Conductor: Stranded

More information

Data sheet chainflex CF270.UL.D

Data sheet chainflex CF270.UL.D For detailed overview please see design table 1. Outer jacket: Pressure extruded PUR mixture 2. Overall shield: Bending-resistant braiding made of tinned copper wires. 3. Banding: Plastic fleece 4. Core

More information

BlueLine Cables for Shipbuilding

BlueLine Cables for Shipbuilding BlueLine Cables for Shipbuilding www.sab-worldwide.com Content page The Company..........................................................................................................................

More information

Technical Data Sheet Shielded (CY) PVC Control Cable

Technical Data Sheet Shielded (CY) PVC Control Cable Technical Data Sheet Shielded (CY) PVC Control Cable MachFlex 375 CY Tinned Copper Braid Shield (TCB) Excellent Noise Immunity Applications Designed for applications which are installed in occasional flexing

More information

Data sheet chainflex CF886

Data sheet chainflex CF886 1. Outer jacket: Pressure extruded PVC mixture 2. Overall shield: Braiding made of tinned copper wires 3. Banding: Plastic foil 4. Core insulation: Mechanically high-quality PVC mixture 5. Conductor: Conductor

More information

PRODUCT INFORMATION H07V-K

PRODUCT INFORMATION H07V-K GmbH PRODUCT INFORMATION European cable type certification Cables' marking also stands for the international endorsement of national certification institutes' testing marks and certificates,

More information

Power & Control Cables

Power & Control Cables The Quality Connection Power & Control Cables U o /U 0.6/1 kv - IEC 60502-1 2 The Quality Connection www.leoni-industrial-projects.com The LEONI Group Cable expertise for the most various industrial markets.

More information

Industrial Ethernet Cables

Industrial Ethernet Cables Industrial Ethernet Cables www.sab-worldwide.com INDUSTRIAL ETHERNET CABLES Content page Application of Industrial ETHERNET Cables.........................................................................................

More information

This document is a preview generated by EVS

This document is a preview generated by EVS EESTI STANDARD EVS-EN 50272-3:2003 Safety requirements for secondary batteries and battery installations - Part 3: Traction batteries Safety requirements for secondary batteries and battery installations

More information

SABIX Ultra. Standards: EN EN Cat C or D IEC (halogen-free)

SABIX Ultra. Standards: EN EN Cat C or D IEC (halogen-free) SABIX Ultra Standards: EN 60332-1-2 EN 60332-3 Cat C or D IEC 60754-1 (halogen-free) IEC 60754-2 + EN 50267-2-2 (corrosivity of gases) EN 61034 (smoke density) NF C 32-70 C1 (fire performance acc. to French

More information

14 HH EAC/CTP CE RoHS-II conform

14 HH EAC/CTP CE RoHS-II conform Outer jacket: Pressure extruded PUR mixture Inner jacket: Pressure extruded, gusset filling PUR mixture 12 cores or more: Bundles with optimized pitch length and pitch direction Conductor: Fine-wire strand

More information

6491B / H07Z-R / BS EN Cable

6491B / H07Z-R / BS EN Cable 6491B / H07Z-R / BS EN 50525-3-41 Cable Eland Product Group: A3Z APPLICATION Suitable for use in conduit and for fixed, protected installation. For installations where fire, smoke emission and toxic fume

More information

This document is a preview generated by EVS

This document is a preview generated by EVS TECHNICAL SPECIFICATION CLC/TS 50537-3 SPÉCIFICATION TECHNIQUE TECHNISCHE SPEZIFIKATION February 2010 ICS 29.180; 45.060.10 English version Railway applications - Mounted parts of the traction transformer

More information

SOUTH AFRICAN NATIONAL STANDARD

SOUTH AFRICAN NATIONAL STANDARD ISBN 978-0-626-31521-4 EN 300:2006 SOUTH AFRICAN NATIONAL STANDARD Oriented Strand Boards (OSB) Definitions, classification and specifications This national standard is the identical implementation of

More information

Data sheet chainflex CF886

Data sheet chainflex CF886 1. Outer jacket: Pressure extruded PVC mixture 2. Overall shield: Braiding made of tinned copper wires 3. Shield foil: Aluminium clad plastic foil 4. Banding: Plastic foil 5. Filling: Plastic yarns 6.

More information

ENERGY. TECWATER EMV-FC S1BC4N8-F 0,6/1 kv. Screened Cable for Water Application

ENERGY. TECWATER EMV-FC S1BC4N8-F 0,6/1 kv. Screened Cable for Water Application ENERGY TECWATER EMV-FC S1BC4N8-F 0,6/1 kv Screened Cable for Water Application Technical Data Trademark Type designation Specification Application TECWATER EMV-FC S1BC4N8-F Design and tests according to

More information

5.3. HellermannTyton product standards. Standards Overview. CSA Canadian Standards Association Canada. cul Canadian Underwriters Laboratories Canada

5.3. HellermannTyton product standards. Standards Overview. CSA Canadian Standards Association Canada. cul Canadian Underwriters Laboratories Canada 5.3 Appendix Standards Overview CSA Canadian Standards Association Canada cul Canadian Underwriters Laboratories Canada BV Bureau Veritas France DEF STAN Defence Standard Great Britain DNV Det Norske Veritas

More information

PRODUCT INFORMATION. UNITRONIC SPIRAL LiF2Y11Y. Info New: the unscreened spiral cables with small cross section High restoring forces PUR outer sheath

PRODUCT INFORMATION. UNITRONIC SPIRAL LiF2Y11Y. Info New: the unscreened spiral cables with small cross section High restoring forces PUR outer sheath Spiral cable with outer PUR sheath for exact impulse transmission, unshielded - PUR spiral cable, abrasion-resistant data and control cable for use in data processing, measurement and control engineering

More information

English version. This Technical Specification was approved by CENELEC on

English version. This Technical Specification was approved by CENELEC on TECHNICAL SPECIFICATION CLC/TS 60034-31 SPÉCIFICATION TECHNIQUE TECHNISCHE SPEZIFIKATION February 2011 ICS 29.160 English version Rotating electrical machines - Part 31: Selection of energy-efficient motors

More information

SPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING CABLES FOR RAILWAY TECHNOLOGY. den-belitsky / Fotolia

SPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING CABLES FOR RAILWAY TECHNOLOGY. den-belitsky / Fotolia SPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING CABLES FOR RAILWAY TECHNOLOGY den-belitsky / Fotolia CONTENT OVERVIEW Who we are.........................................................................................................

More information

RESILIENT AND LAMINATE FLOOR COVERINGS - CASTOR CHAIR TEST IRISH STANDARD I.S. EN 425:2002. Price Code. Údarás um Chaighdeáin Náisiúnta na héireann

RESILIENT AND LAMINATE FLOOR COVERINGS - CASTOR CHAIR TEST IRISH STANDARD I.S. EN 425:2002. Price Code. Údarás um Chaighdeáin Náisiúnta na héireann IRISH STANDARD I.S. EN 425:2002 ICS 97.150 National Standards Authority of Ireland Dublin 9 Ireland Tel: (01) 807 3800 Tel: (01) 807 3838 RESILIENT AND LAMINATE FLOOR COVERINGS - CASTOR CHAIR TEST NSAI

More information

Data sheet chainflex CF140.UL

Data sheet chainflex CF140.UL 1. Outer jacket: Pressure extruded PVC mixture 2. Overall shield: Bending-resistant braiding made of tinned copper wires 3. Inner jacket: Pressure extruded, gusset-filling PVC mixture 4. CFRIP: Tear strip

More information

CRANE, CONVEYOR, LIFT & REELING CABLES

CRANE, CONVEYOR, LIFT & REELING CABLES CRANE, CONVEYOR, LIFT & REELING CABLES F-PVC Series... 158 F-TPECY Series...160 P Series...161 PR Series...162 PRRT Series... 164 PRVS Series...166 Reeling/Trailing Cable Enquiry Form...168 P: (09) 264

More information

Installation Devices 4

Installation Devices 4 Installation Devices 4 4.1 Tapes HelaTape Flex - Vinyl Electrical Tapes HelaTape Wrap - Vinyl Tapes HelaTape Shield - Conductive Tapes HelaTape Flex 15 - All Purpose Vinyl Insulating Tape HelaTape Flex

More information

DEUTSCHE NORM May 2004 DIN EN ISO 4029 { Hexagon socket set screws with cup point (ISO 4029 : 2003) English version of DIN EN ISO 4029

DEUTSCHE NORM May 2004 DIN EN ISO 4029 { Hexagon socket set screws with cup point (ISO 4029 : 2003) English version of DIN EN ISO 4029 DEUTSCHE NORM May 2004 DIN EN ISO 4029 { ICS 21.060.10 Supersedes DIN 916, December 1980 edition. Hexagon socket set screws with cup point (ISO 4029 : 2003) English version of DIN EN ISO 4029 Gewindestifte

More information

The cables you need when you need them

The cables you need when you need them The cables you need when you need them Whether you need standard or specialist cables you re looking in the right place. With a massive range available on short lead-times we can deliver the product you

More information

H07RN-F TITANEX PREMIUM

H07RN-F TITANEX PREMIUM New generation of flexible cables elastomer H07RN-F, born to release you from all the constraints. Thanks to its specific technology, it includes the properties of H07RN8-F; H07BN4-F; H07BB-F. Description

More information

METALLIC MATERIALS - CONVERSION OF HARDNESS VALUES (ISO 18265:2003) IRISH STANDARD I.S. EN ISO 18265:2003. Price Code

METALLIC MATERIALS - CONVERSION OF HARDNESS VALUES (ISO 18265:2003) IRISH STANDARD I.S. EN ISO 18265:2003. Price Code IRISH STANDARD I.S. EN ISO 18265:2003 ICS 77.040.01 National Standards Authority of Ireland Dublin 9 Ireland Tel: (01) 807 3800 Tel: (01) 807 3838 METALLIC MATERIALS - CONVERSION OF HARDNESS VALUES (ISO

More information

DEUTSCHE NORM June Plastics Symbols and abbreviated terms Part 1: Basic polymers and their special characteristics (ISO : 2001)

DEUTSCHE NORM June Plastics Symbols and abbreviated terms Part 1: Basic polymers and their special characteristics (ISO : 2001) DEUTSCHE NORM June 2002 Plastics Symbols and abbreviated terms Part 1: Basic polymers and their special characteristics (ISO 1043-1 : 2001) English version of DIN EN ISO 1043-1 { EN ISO 1043-1 ICS 01.040.83;

More information

SOUTH AFRICAN NATIONAL STANDARD

SOUTH AFRICAN NATIONAL STANDARD ISBN 978-0-626-32581-7 SOUTH AFRICAN NATIONAL STANDARD Gravity drainage systems inside buildings Part 3: Roof drainage, layout and calculation This national standard is the identical implementation of,

More information