Any inquiries, please feel free to contact or Caledonian
|
|
- Ashley Black
- 6 years ago
- Views:
Transcription
1 Caledonian Low Voltage cables to IEC Standard Addison
2 Company Profile Caledonian. established in 1978.offers one of the most complete lines of fiber and copper cabling system solutions with over hundreds of different cabling system products.. Our superior products provide leading edge within every cable series and for every application. Among the national and international standards with which our cables could comply are: BS - British Standard; LPCB Fire Performance Standard. ISO Standard etc. Caledonian s offers a comprehensive stock of cables and cabling products through its nationwide network of resellers and distributors. Caledonian s has continually expanded its global presence in Europe and Asia. Caledonian & Addison. produces a wide range of cables for communication. power and electronics in its primary plants in UK. Italy and Spain. To stay in front. we continually keep expanding our manufacturing capabilities in more low cost region such as Romania. Taiwan. Malaysia etc. This low-cost manufacturing facilities enable us provide a flexible. scalable global system that delivers superior operational performance and optimal results for our customers. Our extensive global network of manufacturing facilities gives us significant scale and the flexibility to fulfill our customer requirements. This global presence provides design and consultancy solutions that are combined with core cable manufacturing. logistic services. and vertically integrated with our E commerce technologies. to optimize customer operations by lowering costs and reducing time to market. Caledonian & Addison has been respected for its high standards of quality. excellent service level. competitive pricing and a unique and innovative spirit. With our latest technologies. we are both inspired and well-positioned to meet the changing needs of our customers. We have the resources to diversify and to enhance our product lines and services. We understand the need for change and with our accurate planning. we are ready for the future and the promise of new marketing opportunities. Our tradition of growth through excellence is assured. Our Design Centers work closely with customers to constantly improve its standard range of products and technologies and to develop customized. country and industryspecific solutions. Caledonian & Addison has established an extensive network of design. manufacturing. and logistics facilities in the world s major markets to serve the growing outsourcing needs of both multinational and regional customers. 2
3 Our Certificate Any inquiries, please feel free to contact 3
4 Table of Content 600/1000V, PVC Insulated s according to IEC Single core(unarmoured) Two core(unarmoured) Three core(unarmoured) Three core +1(unarmoured) Four core(unarmoured) Multi- core(unarmoured) Single core(armoured) Two core(armoured) Three core(armoured) Three core +1(armoured) Four core(armoured) 600/1000V, XLPE Insulated s according to IEC Single core(unarmoured) Two core(unarmoured) Three core(unarmoured) Three core +1(unarmoured) Four core(unarmoured) Multi- core(unarmoured) Single core(armoured) Two core(armoured) Three core(armoured) Three core +1(armoured) Four core(armoured) 600/1000V, XLPE Insulated and Lead ed s according to IEC Single core(unarmoured) Two core(unarmoured) Three core(unarmoured) Three core +1(unarmoured) Four core(unarmoured) Single core(armoured) Two core(armoured) Three core(armoured) Three core +1(armoured) Four core(armoured) Technical Reference 39 4
5 8 Any inquiries, please feel free to contact 600/1000V, PVC Insulated s according to IEC Single core(unarmoured) Two core(unarmoured) Three core(unarmoured) Three core +1(unarmoured) Four core(unarmoured) Multi- core(unarmoured) Single core(armoured) Two core(armoured) Three core(armoured) Three core +1(armoured) Four core(armoured) 5
6 600/1000V, PVC Insulated s according to IEC Application: These cables are used for electricity supply in low voltage installation system, They are suitable for installation in indoors and outdoors, in cable ducts, under ground, in power and switching stations, local energy distributions, industrial plants, where there is no risk of mechanical damage. Construction: s Copper or Aluminium conductor, round standed or Shaped, Class 2 to IEC 60228, BS EN For smaller sizes, a solid round conductor, Class 1 as per IEC 60228, BS EN can also be supplied upon request. PVC material and shall be as per IEC and BS PVC material shall be Type A as per IEC or TI1 as per BS EN PVC material as per SASO 1694 rated for 85 C continuous operation is also available upon special request. Colour Code Colour Code (1) : 1 Core : Red or Black 2 Cores : Red, Black 3 Cores : Red, Yellow, Blue 4 Cores : Red, Yellow, Blue, Black 5 Cores : Red, Yellow, Blue, Black, Green Above 5 Cores: Black Cores with White numerals Colour Code (2) : 1 Core : Brown or Blue 2 Cores : Brown, Blue 3 Cores : Brown, Black, Grey 4 Cores : Blue, Brown, Black, Grey 5 Cores : Green/Yellow, Blue, Brown, Black, Grey Above 5 Cores: Black Cores with White numerals 6
7 Assembly / Inner Armour Outer Fire Performance of s Two, Three or Four insulated conductors are laid-up together with non-hygroscopic fillers and the assembly is bedded with an extruded layer of PVC. In case of nonarmoured cables, this layer may be omitted Aluminum/Galvanized Steel Wires applied helically over the bedding as per IEC or as per BS 5467, BS Single core cables shall be Aluminium wire armour, Aluminum/Steel Tapes applied helically over the bedding of multi-core cables as per IEC Outer sheath shall be of Extruded PVC Type ST2 as per IEC or Type 9 as BS 6346/5467. Special type of PVC sheathing material such as Fire Retardant PVC, Anti-Termite PVC, Anti-Rodent PVC, Sunlight resistant PVC, Oil Resistant PVC are available on special request. Also, special sheathing materials such as LLDPE, MDPE, HDPE, LSF, CPE are available on request. s can be supplied with special flame retardant PVC outer sheath to comply with the flame test requirements of IEC , IEC and IEC , can also supply cables with Low Smoke Halogen Free (LSHF) material according to IEC , BS 7211, BS 6724 or other equivalent standards. Parameters: Single core(unarmoured) PVC insulation PVC jacket of mm² mm mm mm mm Kg/Km 1x x x x x x x x
8 of mm² mm mm mm mm Kg/Km 1x x x x x x x x x Two cores(unarmoured) PVC insulation PVC jacket of mm² mm mm mm mm Kg/Km 2x x x x x x x x x x x x x x x
9 Three cores(unarmoured) PVC insulation PVC jacket of mm² mm mm mm mm Kg/Km 3x x x x x x x x x x x x x x x x x Three cores+1(unarmoured) PVC jacket PVC insulation 9
10 of mm² (3)mm (1)mm (3)mm (1)mm mm mm Kg/Km 3x 16/ x 25/ x 35/ x 50/ x 70/ x 95/ x120/ x150/ x185/ x240/ x300/ x400/ Four cores(unarmoured) PVC jacket PVC insulation of mm² mm mm mm mm Kg/Km 4x x x x x x x x x
11 of mm² mm mm mm mm Kg/Km 4x x x x x x x x Multi-cores(unarmoured) PVC insulation PVC jacket of mm² mm mm mm mm Kg/Km 5x x x x x x x x x x x x x x
12 of mm² mm mm mm mm Kg/Km 10x x x x x x x x x x Single core( aluminum wire armoured) PVC bedding PVC insulation Aluminum wire armour PVC jacket of bedding Alum Wire dia. mm² mm mm mm mm mm mm Kg/Km 1x x x x x x x x x x x x x x x
13 Two cores(galvanized steel wire armoured) of PVC bedding PVC insulation Galvanized steel wire armour PVC jacket bedding Steel Wire dia. mm² mm mm mm mm mm mm Kg/Km 2x x x x x x x x Three cores(galvanized steel wire armoured) PVC bedding PVC insulation Galvanized steel wire armour PVC jacket of bedding Steel Wire dia. mm² mm mm mm mm mm mm Kg/Km 3x2.5 rm x4 re x4 rm x6 re x6 rm x10 re x10 rm x16 rm x25 rm
14 of bedding Steel Wire dia. mm² mm mm mm mm mm mm Kg/Km 3x35 rm x50 sm x70 sm x95 sm x120 sm x150 sm x185 sm x240 sm x300 sm x400 sm x500 sm Three cores+1(galvanized steel wire armoured) of PVC bedding PVC insulation Galvanized steel wire armour PVC jacket bedding Steel Wire dia. mm² mm mm mm mm mm mm mm mm Kg/Km 3x10 rm x16 rm x25 rm x35 sm x50 sm x70 sm x95 sm x120 sm x150 sm x185 sm x240 sm x300 sm x400 sm x500 sm
15 Four cores(galvanized steel wire armoured) PVC bedding PVC insulation Galvanized steel wire armour PVC jacket of bedding Steel Wire dia. mm² mm mm mm mm mm mm Kg/Km 4x4 re x4 rm x6 re x6 rm x10 re x10 rm x16 rm x25 rm x35 sm x50 sm x70 sm x95 sm x120 sm x150 sm x185 sm x240 sm x300 sm x400 sm x500 sm
16 600/1000V, XLPE Insulated s according to IEC Single core(unarmoured) Two core(unarmoured) Three core(unarmoured) Three core +1(unarmoured) Four core(unarmoured) Multi- core(unarmoured) Single core(armoured) Two core(armoured) Three core(armoured) Three core +1(armoured) Four core(armoured) 16
17 600/1000V, XLPE Insulated s according to IEC Application: These cables are used for electricity supply in low voltage installation system, They are suitable for installation in indoors and outdoors, in cable ducts, under ground, in power and switching stations, local energy distributions, industrial plants, where there is no risk of mechanical damage. Construction: s Copper or Aluminium conductor, round standed or Shaped, Class 2 to IEC 60228, BS EN For smaller sizes, a solid round conductor, Class 1 as per IEC 60228, BS EN can also be supplied upon request. XLPE material and shall be as per IEC or BS 5467 rated for 90 C continuous operation. Colour Code Colour Code (1) : 1 Core : Red or Black 2 Cores : Red, Black 3 Cores : Red, Yellow, Blue 4 Cores : Red, Yellow, Blue, Black 5 Cores : Red, Yellow, Blue, Black, Green Above 5 Cores: Black Cores with White numerals Assembly / Inner Colour Code (2) : 1 Core : Brown or Blue 2 Cores : Brown, Blue 3 Cores : Brown, Black, Grey 4 Cores : Blue, Brown, Black, Grey 5 Cores : Green/Yellow, Blue, Brown, Black, Grey Above 5 Cores: Black Cores with White numerals Two, Three or Four insulated conductors are laid-up together with non-hygroscopic fillers and the assembly is bedded with an extruded layer of PVC. In case of nonarmoured cables, this layer may be omitted 17
18 Armour Outer Fire Performance of s Aluminum/Galvanized Steel Wires applied helically over the bedding as per IEC or as per BS 5467, BS Single core cables shall be Aluminium wire armour, Aluminum/Steel Tapes applied helically over the bedding of multi-core cables as per IEC Outer sheath shall be of Extruded PVC Type ST2 as per IEC or Type 9 as BS 6346/5467. Special type of PVC sheathing material such as Fire Retardant PVC, Anti-Termite PVC, Anti-Rodent PVC, Sunlight resistant PVC, Oil Resistant PVC are available on special request. Also, special sheathing materials such as LLDPE, MDPE, HDPE, LSF, CPE are available on request. s can be supplied with special flame retardant PVC outer sheath to comply with the flame test requirements of IEC , IEC and IEC , can also supply cables with Low Smoke Halogen Free (LSHF) material according to IEC , BS 7211, BS 6724 or other equivalent standards. Parameters: Single core(unarmoured) XLPE insulation PVC jacket of mm² mm mm mm mm Kg/Km 1x x x x x x x x x
19 of mm² mm mm mm mm Kg/Km 1x x x x x x x x x x x x Two cores(unarmoured) XLPE insulation PVC jacket of mm² mm mm mm mm Kg/Km 2x x x x x x x x x x x
20 of mm² mm mm mm mm Kg/Km 2x x x x x x Three cores(unarmoured) XLPE insulation PVC jacket of mm² mm mm mm mm Kg/Km 3x x x x x x x x x x x x x x x x x
21 Three cores+1(unarmoured) PVC jacket XLPE insulation of mm² (3)mm (1)mm (3)mm (1)mm mm mm Kg/Km 3x 16/ x 25/ x 35/ x 50/ x 70/ x 95/ x120/ x150/ x185/ x240/ x300/ x400/ Four cores(unarmoured) PVC jacket XLPE insulation of mm² mm mm mm mm Kg/Km 4x x
22 of mm² mm mm mm mm Kg/Km 4x x x x x x x x x x x x x x x Multi-cores(unarmoured) XLPE insulation PVC jacket of mm² mm mm mm mm Kg/Km 5x x x x x x x
23 of mm² mm mm mm mm Kg/Km 24x x x x x x x x x x x x x x x x x Single core( aluminum wire armoured) PVC bedding XLPE insulation Aluminum wire armour PVC jacket of bedding Alum Wire dia. mm² mm mm mm mm mm mm Kg/Km 1x x x x x x
24 of bedding Alum Wire dia. mm² mm mm mm mm mm mm Kg/Km 1x x x x x x x Two cores(galvanized steel wire armoured) of bedding Steel Wire dia. mm² mm mm mm mm mm mm Kg/Km 2x x x x x x x x x x x x x x x x x PVC bedding XLPE insulation Galvanized steel wire armour PVC jacket
25 Three cores(galvanized steel wire armoured) PVC bedding XLPE insulation Galvanized steel wire armour PVC jacket of bedding Steel Wire dia. mm² mm mm mm mm mm mm Kg/Km 3x x x x x x x x x x x x x x x x x Three cores+1(galvanized steel wire armoured) PVC bedding XLPE insulation Galvanized steel wire armour PVC jacket 25
26 mm² of (3) (1) mm mm (3) (1) mm mm bedding Steel Wire dia. mm mm mm mm Kg/Km 3x 16/ x 25/ x 35/ x 50/ x 70/ x 95/ x120/ x150/ x185/ x240/ x300/ x400/ Four cores(galvanized steel wire armoured) PVC bedding XLPE insulation Galvanized steel wire armour PVC jacket of bedding Steel Wire dia. mm² mm mm mm mm mm mm Kg/Km 4x x x x x x x x x x
27 of bedding Steel Wire dia. mm² mm mm mm mm mm mm Kg/Km 4x x x x x x x
28 600/1000V, XLPE Insulated and Lead ed s according to IEC Single core(unarmoured) Two core(unarmoured) Three core(unarmoured) Three core +1(unarmoured) Four core(unarmoured) Single core(armoured) Two core(armoured) Three core(armoured) Three core +1(armoured) Four core(armoured) 28
29 600/1000V, XLPE Insulated and Lead ed s, according to IEC Application: These cables are used for electricity supply in low voltage installation system, They are suitable for installation in indoors and outdoors, in cable ducts, under ground, in power and switching stations, local energy distributions, industrial plants, where there is no risk of mechanical damage. The lead sheath brings an enhanced resistance to aromatic hydrocarbons. Construction: s s shall be Round Stranded (Non-compacted or Compacted) or shaped, Class 2 as per IEC For smaller sizes up to and including 4 mm2, Solid s, Class 1 to IEC can also be provided based on special request. XLPE material and shall be as per IEC rated for 90 C continuos operation. PVC material and shall be as per IEC and BS PVC material shall be Type A as per IEC or TI1 as per BS PVC material as per SASO 1694 rated for 85 C continuous operation is also available upon special request. Colour Code Colour Code (1) : 1 Core : Red or Black 2 Cores : Red, Black 3 Cores : Red, Yellow, Blue 4 Cores : Red, Yellow, Blue, Black 5 Cores : Red, Yellow, Blue, Black, Green Above 5 Cores: Black Cores with White numerals Colour Code (2) : 1 Core : Brown or Blue 2 Cores : Brown, Blue 3 Cores : Brown, Black, Grey 4 Cores : Blue, Brown, Black, Grey 5 Cores : Green/Yellow, Blue, Brown, Black, Grey Above 5 Cores: Black Cores with White numerals 29
30 Assembly / Bedding Lead Seperation Armour Outer Two, Three or Four insulated conductors are laid-up together with non-hygroscopic fillers compatible with the insulation material and the assembly is bedded with an extruded layer of PVC. Extruded lead Alloy Type "E" to BS of lead shall be as per IEC s with other of Lead can also be provided based on specific request. The seperation sheath shall be of Extruded PVC Type ST2 as per IEC Galvanized Steel Wires in accordance with IEC or BS 6346 or BS 5467 laid helically over PVC bedding as per requirement. Galvanized Steel Tapes applied helically over PVC bedding in accordance with IEC Outer sheath shall be of Extruded PVC Type ST2 as per IEC or Type 9 as BS 6346/5467. Special type of PVC sheathing material such as Fire Retardant PVC, Anti-Termite PVC, Anti-Rodent PVC, Sunlight resistant PVC, Oil Resistant PVC are available on special request. Also, special sheathing materials such as LLDPE, MDPE, HDPE, LSF, CPE are available on request. Parameters: XLPE insulation Lead sheath PVC jacket Single core(unarmoured) of Lead mm² mm mm mm mm mm Kg/Km 1x10 rm x16 rm x25 rm x35 rm x50 rm
31 of Lead mm² mm mm mm mm mm Kg/Km 1x70 rm x95 rm x120 rm x150 rm x185 rm x240 rm x300 rm x400 rm x500 rm x630 rm Lead sheath XLPE insulation PVC bedding PVC outer sheath Two cores(unarmoured) of Lead mm² mm mm mm mm mm Kg/Km 2x2.5 rm x4 rm x6 rm x10 rm x16 rm x25 rm x35 rm x50 rm
32 Three cores(unarmoured) Lead sheath XLPE insulation PVC bedding PVC jacket of Lead mm² mm mm mm mm mm Kg/Km Round conductor 3x1.5 rm x2.5 rm x4 rm x6 rm x10 rm x16 rm x25 rm x35 rm x50 rm x70 rm x95 rm x120 rm x150 rm x185 rm x240 rm x300 rm Sectoral conductor 3x50 sm x70 sm x95 sm x120 sm x150 sm x185 sm x240 sm x300 sm
33 Three cores+1(unarmoured) of Lead mm² (3) mm mm (1) mm (3) mm (1) mm mm mm Kg/Km 3x10 rm+6 rm x16 rm+10 rm x25 rm+16 rm x35 sm+16 rm x50 sm+25 rm x70 sm+35 rm x95 sm+50 rm x120 sm+70 rm x150 sm+70 rm x185 sm+95 rm x240 sm+120 rm x300 sm+150 rm Four cores(unarmoured) Lead sheath XLPE insulation PVC bedding PVC jacket of Lead mm² mm mm mm mm mm Kg/Km 4x1.5 rm
34 of Lead mm² mm mm mm mm mm Kg/Km 4x2.5 rm x4 rm x6 rm x10 rm x16 rm x25 rm x35 sm x50 sm x70 sm x95 sm x120 sm x150 sm x185 sm x240 sm x300 sm Single core( aluminum wire armoured) of Aluminum wire armour PVC bedding XLPE insulation Lead sheath PVC seperation sheath PVC outer sheath Lead dia. of Aluminium wire armour mm² mm mm mm mm mm Kg/Km Kg/Km 1x35 rm x50 rm x70 rm x95 rm x120 rm x150 rm
35 of Lead dia. of Aluminium wire armour mm² mm mm mm mm mm Kg/Km Kg/Km 1x185 rm x240 rm x300 rm x400 rm x500 rm x630 rm Two cores(galvanized steel wire armoured) of Galvanized steel wire armour XLPE insulation PVC bedding Lead sheath PVC seperation sheath PVC outer sheath Lead dia. of Steel wire armour mm² mm mm mm mm mm Kg/Km Kg/Km 2x2.5 rm x4 rm x6 rm x10 rm x16 rm x25 rm x35 rm x50 rm
36 Three cores(galvanized steel wire armoured) of Galvanized steel wire armour XLPE insulation PVC bedding Lead sheath PVC seperation sheath PVC outer sheath Lead dia. of Steel wire armour mm² mm mm mm mm mm Kg/Km Kg/Km 3x1.5 rm x2.5 rm x4 rm x6 rm x10 rm x16 rm x25 rm x35 rm x50 rm x70 rm x95 rm x120 rm x150 rm x185 rm x240 rm x300 rm x50 sm x70 sm x95 sm x120 sm x150 sm x185 sm x240 sm x300 sm
37 Three cores+1(galvanized steel wire armoured) Galvanized steel wire armour PVC bedding XLPE insulation Lead sheath PVC seperation sheath PVC outer sheath Lead dia. of Steel Wire armour mm² (3) mm (1) mm mm mm mm mm Kg/Km 3x10 rm+6 rm x16 rm+10 rm x25 rm+16 rm x35 sm+16 rm x50 sm+25 rm x70 sm+35 rm x95 sm+50 rm x120 sm+70 rm x150 sm+70 rm x185 sm+95 rm x240 sm+120 rm x300 sm+150 rm Four cores(galvanized steel wire armoured) Galvanized steel wire armour PVC bedding XLPE insulation Lead sheath PVC seperation sheath PVC outer sheath Galvanized steel wire armour PVC bedding XLPE insulation Lead sheath PVC seperation sheath PVC outer sheath 37
38 of Lead dia. of Steel wire armour mm² mm mm mm mm mm Kg/Km Kg/Km 4x1.5 rm x2.5 rm x4 rm x6 rm x10 rm x16 rm x25 rm x35 sm x50 sm x70 sm x95 sm x120 sm x150 sm x185 sm x240 sm x300 sm
39 Technical Referrence Options Mechnical Characteristics of Mechnical Characteristics of Jacket Materials Electrical Characteristics of Single Core s Electrical Characteristics of Three Core s 39
40 Options Either PVC, XLPE or EPR can be offered upon request of PVC/A insulation cross-sectional area of conductor of insulation at rated voltage U0/U (Um) mm2 0.6/1 (1.2) kv mm 1.5 and /3 (3.6) kv mm 4 and and and and and to of cross-linked polyethylene (XLPE) insulation cross-sectional area of conductor of insulation at rated voltage U0/U (Um) mm2 0.6/1 (1.2) kv mm 1.5 and /3 (3.6) kv mm 4 and and and and
41 cross-sectional area of conductor of insulation at rated voltage U0/U (Um) mm2 0.6/1 (1.2) kv mm /3 (3.6) kv mm of ethylene propylene rubber (EPR) and hard ethylene propylene rubber (HEPR) insulation crosssectional area of conductor 41 mm 2 of insulation at rated voltage U0/U (Um) ERP mm 0,6/1 (1,2) kv HEPR mm ERP mm 1.8/3 (3.6) kv mm HEPR mm 1,5 and 2,5 1,0 0, and 6 1,0 0, and 16 1,0 0,7 2,2 2,0 25 and 35 1,2 0,9 2,2 2,0 50 1,4 1,0 2,2 2,0 70 1,4 1,1 2,2 2,0 95 1,6 1,1 2,4 2, ,6 1,2 2,4 2, ,8 1,4 2,4 2, ,0 1,6 2,4 2, ,2 1,7 2,4 2, ,4 1,8 2,4 2, ,6 2,0 2,6 2, ,8 2,2 2,8 2, ,8 2,4 2,8 2, ,8 2,6 2,8 2, ,0 2,8 3,0 2,8
42 Mechanical Characteristics of Materials Mechanical characteristics of insulating compounds with copper conductor (before and after aging) Designation of compounds Maximum conductor temperature in normal operation Without ageing (IEC ,) Tensile strength, minimum Elongation-at-break, minimum After ageing without conductor Treatment: temperature tolerance duration Tensile strength a) value after ageing, minimum b) variation a, maximum Elongation-at-break: a) value after ageing, minimum b) variation a, maximum After ageing with copper conductor followed by the tensile test b Treatment: temperature tolerance duration Unit PVC/A EPR HEPR XLPE 0,6/1(1,2) All 0,6/1(1,2) All kv other kv other 0,6/1(1,2) All cables cables cables cables kv cables other cables C N/ mm 2 % C C h N/ mm 2 % % % C C h 12, ± ,5 ± ±25 Tensile strength: Variation a, maximum % ±30 ±30 ±30 Elongation-at-break: Variation a, maximum % ±30 ±30 ±30 After ageing with copper conducto r followed by bending test (only if the tensile test is not practicable) b Treatment: temperature tolerance duration C C h Results to be obtained 4, ±3 168 ±30 ± ± ±3 240 No cracks 4, ±3 168 ±30 ±30 8, ±3 168 ±30 ± ± ±3 240 No cracks 8, ±3 168 ±30 ±30 12, ±3 168 ±25 ± ± ±3 240 No cracks 12, ±3 168 ±25 ±25 42
43 Mechanical Characteristics of Jacket Materials Mechanical characteristics of sheathing compounds (before and after aging) Designation of compounds Unit ST1 ST2 ST3 ST7 ST8 SE1 Maximum conductor temperature in normal operation C Without ageing (IEC ) Tensile strength, minimum Elongation-at-break, minimum After ageing in an air oven (IEC ) Treatment: temperature (tolerance ±2 C) duration Tensile strength: a) value after ageing, minimum b) variation a, maximum Elongation-at-break: a) value after ageing, minimum b) variation a, maximum N/mm 2 % C h N/mm 2 % % % 12, ,5 ± ±25 12, ,5 ± ±25 10, Mechanical characteristics for PVC sheathing compounds 12, , ,0 ± ±40 10, ± ±40 Designation of compound Unit ST1 ST2 Use of the PVC compound Loss of mass in an air oven (IEC ) Treatment: temperature (tolerance ±2 C) duration Maximum loss of mass Pressure test at high temperature (IEC ) - temperature (tolerance ±2 C) Behaviour at low temperature a (IEC ) Test to be carried out without previous ageing: - cold bending test for diameter <12,5 mm - temperature (tolerance ±2 C) Cold elongation test on dumb-bells: - temperature (tolerance ±2 C) Cold impact test: - temperature (tolerance ±2 C) Heat shock test (IEC ) Treatment: temperature (tolerance ±3 C) duration C h g/cm ,5 C C C C C h
44 Mechanical characteristics of thermoplastic PE sheathing compounds Designation of compounds Unit ST3 ST7 Density (IEC ) Carbon black content (for black oversheaths only) (IEC ) value Tolerance Shrinkage test (IEC ) Treatment: temperature (tolerance ±2 C) heating, duration heating, cycles Maximum shrinkage % % C h % 2,5 ±0,5 Pressure test at high temperature (IEC ) temperature (tolerance ±2 C) C 110 Mechanical characteristics of halogen free sheathing compound ,5 ±0, Designation of compound Unit ST8 Behaviour at low temperature a (IEC ) Test to be carried out without previous ageing: cold bending test for diameter <12,5 mm temperature (tolerance ±2 C) Cold elongation test on dumb-bells: temperature (tolerance ±2 C) Cold impact test: temperature (tolerance ±2 C) C C C Pressure test at high temperature (IEC ) temperature (tolerance ±2 C) C 80 Water absorption (IEC ) Gravimetric method: Treatment: temperature (tolerance ±2 C) duration Maximum increase of mass C h g/ cm
45 Mechanical characteristics of elastomeric sheathing compound Designation of compound Unit SE1 Oil immersion test followed by a determination of the mechanical properties (IEC and IEC ) Treatment: oil temperature (tolerance ±2 C) duration Maximum variation aof: a) tensile strength b) elongation-at-break Hot set test (IEC ) Treatment: temperature (tolerance ±3 C) time under load mechanical stress Maximum elongation under load Maximum permanent elongation after cooling C H % % C min N/cm 2 % % ±40 ±40 Electrical Characteristics of Single Core s PVC insulation, PVC sheath cables with copper conductor LOW VOLTAGE SINGLE CORE CABLE LINEAR RESISTANCE, REACTANCE AND VOLTAGE DROP PVC INSULATED (85 C) SIZE mm² Direct Current Resistance at 20 C, Ohm/Km Direct Current Resistance at 85 C, Ohm/Km Alternating Current Resistance at 85 C, Ohm/Km Reactance Ohm / Km Impedance Ohm / Km Voltage Drop (Phase to Phase) V/A.Km
46 SIZE mm² Direct Current Resistance at 20 C, Ohm/Km Direct Current Resistance at 85 C, Ohm/Km Alternating Current Resistance at 85 C, Ohm/Km Reactance Ohm / Km Impedance Ohm / Km Voltage Drop (Phase to Phase) V/A.Km XLPE insulation, LSF sheath cables with copper conductor LOW VOLTAGE SINGLE CORE CABLE LINEAR RESISTANCE, REACTANCE AND VOLTAGE DROP XLPE INSULATED (90 C) SIZE mm² Direct Current Resistance at 20 C, Ohm/Km Direct Current Resistance at 90 C, Ohm/Km Alternating Current Resistance at 90 C, Ohm/Km Reactance Ohm / Km Impedance Ohm / Km Voltage Drop (Phase to Phase) V/A.Km
47 Electrical Characteristics of Three Core s PVC insulation, PVC sheath cables with copper conductor LOW VOLTAGE MULTI CORE CABLE LINEAR RESISTANCE, REACTANCE AND VOLTAGE DROP PVC INSULATED (85 C) SIZE mm² Direct Current Resistance at 20 C, Ohm/Km Direct Current Resistance at 85 C, Ohm/Km Alternating Current Resistance at 85 C, Ohm/Km Reactance Ohm / Km Impedance Ohm / Km Voltage Drop (Phase to Phase), V/A.Km
48 XLPE insulation, LSF sheath cables with copper conductor LOW VOLTAGE MULTI CORE CABLE LINEAR RESISTANCE, REACTANCE AND VOLTAGE DROP XLPE INSULATED (90 C) SIZE mm² Direct Current Resistance at 20 C, Ohm/Km Direct Current Resistance at 90 C, Ohm/Km Alternating Current Resistance at 90 C, Ohm/Km Reactance Ohm / Km Impedance Ohm / Km Voltage Drop (Phase to Phase) V/A.Km
49 49 Any inquiries, please feel free to contact
50 50 Caledonian s Ltd Merchant Ind. Centre Mill-Lane, Laughton, Lewes, Sussex, BN8 6AJ England United Kingdom Tel: Fax: sales@caledonian-cables.com sales@caledonian-cables.co.uk uk@addison-tech.com
600/1000V, PVC Insulated Cables according to IEC
8 Any inquiries, please feel free to contact 600/1000V, PVC Insulated s according to IEC 60502-1 Single core(unarmoured) Two core(unarmoured) Three core(unarmoured) Three core +1(unarmoured) Four core(unarmoured)
More informationCaledonian. BS 6346 PVC Insulated, Armored Power and Control Cables. Addison.
Caledonian BS 6346 PVC Insulated, Armored Power and Control Cables www.caledonian-s.co.uk www.caledonian-s.com Addison Company Profile Caledonian. established in 1978.offers one of the most complete lines
More informationCaledonian. Caledonian Offshore & Marine Cables. BS 6883 STANDARD (Flame Retardant) BS 7917 STANDARD (Fire Resisitant)
Caledonian Caledonian Offshore & Marine Cables BS 6883 STANDARD (Flame Retardant) BS 7917 STANDARD (Fire Resisitant) Caledonian, established in 1978, offers one of the most complete lines of fiber and
More information600/1000V, XLPE Insulated Cables according to IEC
600/1000V, XLPE Insulated Cables according to IEC 60502-1 Single core(unarmoured) Two core(unarmoured) Three core(unarmoured) Three core +1(unarmoured) Four core(unarmoured) Multi- core(unarmoured) Single
More informationCaledonian Submersible Pump Cables for Oil Industry >> IEEE 1018 >> IEEE 1019 >> API RP 11S5
Caledonian Submersible Pump Cables for Oil Industry >> IEEE 1018 >> IEEE 1019 >> API RP 11S5 Caledonian Windmill Cables COMPANY PROFILE Table of Content Caledonian, established in 1978, offers one of the
More informationBS 6724 Armoured Power Cables, 600/1000V
BS 6724 Armoured Power Cables, 600/1000V Application These cables are used for power and control circuits, they can offer excellent protection through the use of a heavy galvanized steel wire armour. The
More informationCONTROL CABLES CABLES FZE.
CONTROL CABLES CABLES FZE www.markcables.com Index Introduction 03 Particulars & Guarantees 05 Copper Conductor, PVC Insulated, PVC Sheathed Cables 08 Copper Conductor, XLPE Insulated, PVC Sheathed Cables
More informationTechnical Information
Cable Code Designation A cable code of 2 letters (1. and 4.) or 4 letters is used to describe the construction. For example: 1st Letter: Insulation: B: Fire resistant tape + insulation (Halogen-free) R:
More informationPower & Control Cables. U o. /U 0.6/1 kv - IEC
Power & Control Cables U o /U 0.6/1 kv - IEC 60502-1 2 KERPEN GmbH & Co. KG 07.2005 Printing errors excepted. Subject to alteration List of Contents Introduction Page B1 Construction Page B3 Use Page B4
More informationflame Retardant overall screened Instrumentation cables (Multicore)
Caledonian flame Retardant Instrumentation cables www.caledonian-cables.co.uk www.addison-cables.com flame Retardant overall screened Instrumentation cables (Multicore) Re-2X(st)y Re-2X(st)ysWay PVC Outer
More informationMaterials Evolved* BS EN BS EN IEC IEC (Upon customer request) (Red, Black) or (Brown, Blue)
XLPE INSULATED AND PVC OR LOW SMOKE HALOGEN FREE (LSHF) SHEATHED CABLES Voltage Rating (Uo/U) : 00/00V, 1/0V or 00/3V Standards Complied Main Specification Materials Test Methods Flame Retardant Test Test
More informationPower & Control Cables
The Quality Connection Power & Control Cables U o /U 0.6/1 kv - IEC 60502-1 2 The Quality Connection www.leoni-industrial-projects.com The LEONI Group Cable expertise for the most various industrial markets.
More informationFlame Retardant Individual and Overall Screened, Armoured Instrumentation Cables (Multipair)
Caledonian Flame Retardant Instrumentation Cables www.caledonian-cables.co.uk www.addison-cables.com Flame Retardant Individual and Overall Screened, Armoured Instrumentation Cables (Multipair) RE-2X(st)YSWAY
More informationInsulation Colours: Orange (Standard) Natural Natural. Sheath Colours: Orange (Standard) Orange (Standard) Bedding: Black
-I Insulated, non-sheathed Insulated and sheathed Insulated, ed and sheathed 1. : Plain stranded annealed Class 2 Copper. 1.5mm 2 up to 630mm 2 Plain stranded annealed Class 2 Copper. Plain stranded annealed
More informationPower & Control Cable IEC
(2-, 3-, and 4-cores) U 0 Application For electricity supply and control in public networks and industrial plants; suitable for use in zone 1 and zone 2 group ΙΙ classified areas (IEC 60079-14). Recoended
More information600/1000V XLPE Insulated, LSZH Sheathed, Armoured Power Cables (2-5 Cores)
www.caledonian-s.co.uk www.addison-s.com 600/1000V XLPE Insulated, LSZH Sheathed, Armoured Power Cables (2-5 Cores) FTX400 1RZ1-R (CU/XLPE/LSZH 600/1000V Class 2) FTX400 1RZ1MZ1-R (CU/XLPE/LSZH/SWA/LSZH
More information600/1000V XLPE Insulated, PVC Sheathed, Armoured Power Cables (2-5 Cores)
www.caledonian-s.co.uk www.addison-s.com 600/1000V XLPE Insulated, PVC Sheathed, Armoured Power Cables (2-5 Cores) FGD400 1RV-R (CU/XLPE/PVC 600/1000V Class 2) FGD400 1RVMV-R (CU/XLPE/PVC/SWA/PVC 600/1000V
More informationis the UK subsidary of Tele-Fonika Kable S.A., with offices and a warehouse centrally located in Leicestershire.
is the UK subsidary of Tele-Fonika Kable S.A., with offices and a warehouse centrally located in Leicestershire. We are a major supplier of housewiring, low voltage, power and fire resistant cables for
More informationPower & Control Cable IEC
(2-, 3-, 4,- and 5-cores) U 0 Application For electricity supply and control in public networks and industrial plants; suitable for use in zone 1 and zone 2 group ΙΙ classified areas (IEC 60079-14). Recoended
More informationBasic design adapted to Telcordia GR409-CORE / TIA/EIA 568B.3 / ICEA-S
ADDISON Flame Retardant Tight Buffered Distribution Optic cables MTA-B-C-D-Y Tight Buffer Coating Glass Yarn Ripcord(optional) PVC Outer Sheath APPLICATION This cables are used for interconnection of distribution
More informationFR-3S Fire Resistant Cables
FR-3S Fire Resistant Cables APPLICATION This cable is suitable use in fire extinguishing systems to operate sprinklers, control panels, exit lights in high-rise buildings, hotels, hospitals, sub-ways and
More informationCompany Profile. Caledonian Medium Voltage Cables
Caledonian Medium Voltage Cables Company Profile Caledonian develops, manufactures and markets a totally integrated product line of Medium Voltage Cables for a diverse variety of technological applications.
More informationBS EN Natural. (Orange for Non-sheathed) (Red & Black) or (Brown & Blue) (Red, Yellow, Blue) or (Brown, Black, Grey)
LOW SMOKE HALOGEN FREE (LSHF) FIRE RESISTANT CABLES Voltage Rating (Uo/U) : /0V, /7V or 00/00V Standards Complied Main Specification Fire Tests Flame Retardant Test Test on Acid Gas Evolved Smoke Density
More informationYour Partner in Safe Power Solutions. About RESCAB
Your Partner in Safe Power Solutions About RESCAB Red Sea Cables Company (RESCAB) was established as a closed joint stock company in 2008 in the Kingdom of Saudi Arabia with a capital of 370 million SAR.
More informationRG7H1R-1,8/3 26/45 kv RG7H1OR-1,8/3 18/30 kv
Medium voltage - Energy RG7H1R-1,8/3 26/45 kv RG7H1OR-1,8/3 18/30 kv Structure and electrical, physical, mechanical requirements: CEI 20-13 IEC 60502 Flame propagation: EN 60332-1-2 Measurement of partial
More informationPVC SHEATH FLAME RETARDANT CABLE TO IEC60332
600/1000V XLPE Insulated PVC Sheathed Armoured Power Cables -5 Cores CU/XLPE/PVC 600/1000V Class CU/XLPE/PVC/SWA/PVC 600/1000V Class Application: The cables are mainly used in power stations, mass transit
More informationPower & Control Cable IEC
(2-, 3-, and 4-cores) U 0 PVC-Insulation, Application For electricity supply and control in public networks and industrial plants; suitable for use in zone 1 and zone 2 group ΙΙ classified areas (IEC 60079-14).
More informationCiMEC Technologies Pvt. Ltd., 23/H, Meldi Estate, Gota, Ahmedabad, Gujarat. Discipline Electrical Testing Issue Date
Last Amended on - Page 1 of 6 I. CABLES AND ACCESSORIES 1. PVC Insulated Cables Tests on Conductor: Annealing Test (copper) IS 10810 (Part 1):1984 (RA 2011) 0 to 50 % Tensile Test (Aluminium) IS 10810
More informationP High Voltage Catalogue Cables Australia Powering your Project
P +61 8 9367 8978 www.cablesaustralia.com.au High Catalogue Cables Australia Powering your Project CABLES AUSTRALIA PTY LTD HIGH VOLTAGE CATALOGUE ABOUT US Cables Australia is a locally owned and operated
More informationCaledonian Medium Voltage Cables Three Core Cables to VDE 0276-
Three Core Cables to VDE 0276 APPLICATIONS The three core cables are designed for distribution of electrical power with nominal voltage Uo/U ranging from 3.6/6.6KV to 19/33KV and frequency 50Hz. They are
More informationSPECIFICATION S VR 1(4) HALOGEN FREE POWER AND CONTROL CABLE FOR MARINE APPLICATIONS LM-HF 0,6/1 kv and TEMAR PHFX-U 0,6/1 kv APPLICATI
1(4) HALOGEN FREE POWER AND CONTROL CABLE FOR MARINE APPLICATIONS LM-HF 0,6/1 kv and TEMAR PHFX-U 0,6/1 kv APPLICATION Power and control cable for fixed installations. Designed to fulfill requirements
More informationThe cables you need when you need them
The cables you need when you need them Whether you need standard or specialist cables you re looking in the right place. With a massive range available on short lead-times we can deliver the product you
More informationLSZH Fire Resistant Cables
300/500V Single-Core ~ 4-Core Mica Tape Fire Barrier, XLPE Insulated, LSZH Sheathed, Fire Resistant Cable CU/MICA/XLPE/LSZH of the electrical circuit is critical in maintaining power supply. Applications
More informationNA2XSEKY 3 x (25-300) mm² 3.6/6 kv
NA2XSEKY 3 x (25-300) mm² 3.6/6 kv NA2XSEKY 3 x (25-300) mm² 3.6/6 kv (Aluminium, XLPE Insulated, Copper Tape, Lead Sheathed, PVC Sheathed) 25 39.5 3,292 35 43.0 3,824 50 46.0 4,419 70 50.5 5,264 95 54.5
More informationList of Malaysian Standard (MS) for Cables. Prepared by MCMA SWO. Cable - Armoured. Cable - Armoured
List of Malaysian Standard (MS) for Cables Prepared by MCMA SWO NO. PUBLICATIONS 1. MS 2100 : 2007 2. MS 2101 : 2007 3. MS 2102 : 2007 4. MS 2103 : 2007 5. MS 2104 : 2007 6. MS 2105 : 2007 7. MS 2106 :
More informationCaledonian Medium Voltage Cables
Three Core Cables to VDE 0276 APPLICATIONS: The three core cables are designed for distribution of electrical power with nominal voltage Uo/U ranging from 3.6/6.6KV to 19/33KV and frequency 50Hz. They
More informationN2XY IEC XLPE PVC 0.6/1kV Cable
N2XY IEC 60502-1 XLPE PVC 0.6/1kV Cable Eland Product Group: A2N APPLICATION These power and control cables are used for electricity supply in low voltage installation systems. They are well adapted to
More informationTRATOS OIL&GAS NEK606
C A B L E S F O R A M O V I N G W O R L D TRATOS OIL&GAS NEK606 May 2013 Tt 08-13 TRATOS OIL&GAS NEK606 INDEX TRATOS OIL&GAS NEK606 Approvals, quality system and product certification..........................................................................
More informationCaledonian Fire Resistant Optic Fiber Cables
Fire Resistant Optic Cables Fire resistant Central Loose Optic cables Application These cables are characterized by light weight and small diameter, suitable for both aerial and duct installation. They
More information600/1000V XLPE Insulated PVC Sheathed Power Cables (Multicore)
600/1000V XLPE Insulated PVC Sheathed Power Cables (Multicore) FGD400 1RV-R (CU/XLPE/PVC 600/1000V Class 2) Outdoor Cabling Earth Conductor Earth Conductor APPLICATION The cables are mainly used in power
More informationNA2XSEKRY 3 x (25-300) mm² 3.6/6 kv
NA2XSEKRY 3 x (25-300) mm² 3.6/6 kv NA2XSEKRY 3 x (25-300) mm² 3.6/6 kv (Aluminium, XLPE Insulated, Copper Tape, Lead Sheathed,, PVC Sheathed) 25 47.5 5,292 35 50.5 5,960 50 53.5 6,694 70 58.5 7,816 95
More informationSECTORFLEX CABLE CATALOGUE
SECTORFLEX CABLE CATALOGUE SAVING SPACE AND TIME R & D + i SERVING OUR CUSTOMERS PRESENTATION One of the largest companies in the sector worldwide. General Cable is a leading company in the manufacture
More informationCaledonian Medium Voltage Cables
Three Core Cables to VDE 0276 APPLICATIONS: The three core cables are designed for distribution of electrical power with nominal voltage Uo/U ranging from 3.6/6.6KV to 19/33KV and frequency 50Hz. They
More informationI N T R O D U C T I O N
I N T R O D U C T I O N GEMSCAB are being manufactured by the people who have been associated with the industry for over years and understand the requirements their valued customers. The company took up
More informationBS 6724 Copper Conductor Multi Core SWA LSZH BASEC 0.6/1kV Cable
ed Cable BS 6724 Copper Conductor Multi Core SWA LSZH BASEC 0.6/1kV Cable BS 6724 Copper Conductor Multi Core SWA LSZH BASEC 0.6/1kV Cable Eland Product Group: A9L APPLICATION Multi-core LSZH cable with
More informationFiretec BS 7846 LPCB BASEC Approved Power Cable
Firetec BS 7846 LPCB BASEC Approved Power Cable Eland Product Group: A6F APPLICATION Firetec Power is a fire resistant armoured cable suitable for use in fixed installations for power circuits, fire alarm
More informationSY Type Control Cable 0.5mm 2 to 120mm 2 PVC Sheath
Applications Control cables in tool machinery, plant installation, power stations and data equipment. The braided screen of the galvanized steel wires offers the best possible protection against mechanical
More informationMEDIUM VOLTAGE POWER CABLES
MEDIUM VOLTAGE POWER CABLES CONTENTS 1 GENERAL INTRODUCTION 4 TECHNICAL INFORMATION 15 25 35 45 Single Core XLPE Insulated PVC Sheathed Cables UNARMOURED CABLES COPPER UNARMOURED CABLES ALUMINUM ALUMINUM
More informationSolid PE Insulated & LAP Sheathed Air Core/Jelly Filled Cables to DIN VDE 0816
Solid PE Insulated & LAP Sheathed Air Core/Jelly Filled Cables to DIN VDE 0816 APPLICATION The cables are designed for use as connection between central fices. The cables are suitable for installation
More informationDURAREEL TRAILING REELING CABLE
Supplementary Technical Information Reeling and trailing material characteristics: A. Power core conductor Flexible strands tinned annealed copper complies with AS/NZS 1802, AS/NZS 2802, AS/NZS 1125, and
More information0.6/1kV Al-Cu PVC Insulated PVC Sheathed Power Cable
0.6/1kV - PVC Insulated PVC ed Power Cable SPECIFICATIONS AND STANDARDS: 1.IEC60502-1;VDE 0276-603 ;ICEA S-95-658 ;AS/NZS 5000.1; BS; JIS. 2.Rated Voltage: 0.6/1kV 3. Number cores : One core, two cores,
More informationBS 5467 Copper Conductor Multi Core SWA PVC BASEC 0.6/1kV Cable
BS 5467 Copper Conductor Multi Core SWA PVC BASEC 0.6/1kV Cable Eland Product Group: A9S APPLICATION Multi-core PVC cable with steel wire armour (SWA). Power and auxiliary control cables for use in power
More informationINDEX PRODUCT RANGE TRATOSFLEX- NSHTÖU-JZ TRATOSFLEX- NSHTÖU-JZK TRATOSFLEX - NSHTÖU-J TRATOSFLEX- NSHTÖU-JK TRATOSFLEX-OCS NEW TRATOSFLEX-ES *
october 2004 TRATOSFLEX 2 Selection of type of cable in relation to use Recommended Bending Radius INDEX Current carrying capacities for continuos operation Current carrying capacities for intermittent
More informationMedium voltage cables
Medium voltage cables Leading producer of cables and cable systems 2 The TELE-FONIKA Kable Group has been present on the domestic and international cable industry market for more than 25 years. A stable
More informationFlexFlame BFOU(i) 150/250(300)V S3/S7 Instr. cable
Page 1 of 5 5 4 1 2 3 Fire resistant, flame retardant halogen-free instrumentation cable. Mud resistant BFOU(i) 150/250(300)V MGT/EPR/EPR/TCWB/EVA NEK TS 606 CodeS3/S7 Operating temperature : 90 C Operating
More informationINTRODUCTION NUHAS OMAN QUALITY & RELIABILITY.
INTRODUCTION Nuhas Oman LLC, an integral part of The Al Bahja Group of Companies, is a Quality producer of: HV, MV and LV Cables Enamelled Copper Wires Oxygen Free Continuous Cast Copper Wire Rods Drawn
More information0.6/1kV Al-Cu XLPE Insulated PVC Sheathed Power Cable
0.6/1kV Al-Cu XLPE Insulated PVC ed Power Cable SPECIFICATIONS AND STANDARDS 1.IEC;VDE ;ICEA;AS/NZS; BS; JIS. 2.Rated Voltage: 0.6/1kV 3. Number of cores : One core, two cores, three cores, 3+1 cores,
More informationIntroduction. for over a period 4 decades now. Customer satisfaction has been the prime focus of
Introduction GEMSCAB has been associated with marketing and manufacturing Electric s for over a period 4 decades now. Customer satisfaction has been the prime focus GEMSCAB and today it has established
More informationsa B-CABLES nv PROTOLON(ST) NTSCGEWOEU Medium Voltage Flexible Cables for Use In Water sa B-CABLES nv ENERGY
PROTOLON(ST) NTSCGEWOEU Medium Voltage Flexible Cables for Use In Water ENERGY Technical Data Electrical Thermal Type Type designation PROTOLON(ST) NTSCGEWÖU Approvals/ standards DIN VDE 0250 part 813
More informationFlexFlame RFOU(i) 150/250(300)V S1/S5 Instr. cable
Page 1 5 1 1 1 2 3 Flame retardant halogen-free instrumentation cable. Mud resistant RFOU(i) 150/250(300)V EPR/EPR/TCWB/EVA NEK TS 606 CodeS1/S5 Operating temperature : 90 C Operating Voltage : 150/250(300)V
More informationo o blue-brown Fire Performance BS EN BS EN
Standard Power Cables Low age (600/1000 V) Afumex 90 Armoured Power Cable Cable Approvals > Cable approved to BS6724 > Plain annealed copper stranded (Class 2) for ease of handling Insulation > 90 C -linked
More informationFlexFlame BFOU-XFR(i) 150/250(300)V Instr. cable. Standards applied. IEC EN 50200:2006 Annex E
Page 1 of 5 extended Fire Resistant, flame retardant halogen-free instrumentation cable. Mud resistant BFOU-XFR(i) 150/250(300)V MGT/EPR/EPR/TCWB/EVA Operating temperature : 90 C Operating Voltage : 150/250(300)V
More informationLOW VOLTAGE c a b l e s
LOW VOLTAGE c a b l e s MYSORE PLANT SILVASSA PLANT MANUFACTURES A RANGE OF LOW VOLTAGE CABLES AT ITS FACILITIES AT SILVASSA AND MYSORE The Silvassa unit manufactures LV Cables since the year 2000. XLPE/
More information3. Fire Resistant Cables
Fire Resistant Cables The -to-fire is the term used to describe how long a cable continues to operate in a fire. This may be of primary concern, for instance, in life safety of fire fighting installations.
More informationCAAI-S 0,6/1 kv with Public Lighting
For overhead secundary distribution networks. Description Application: For urban and rural overhead secundary distribution networks, with voltages up to 1000 V. Construction: 1. Conductor: Aluminium 1350,
More informationsa B-CABLES nv PROTOLON(ST) NTSCGEWOEU.../3E Medium Voltage Flexible Cables for Use in Water with Copper Core Shield sa B-CABLES nv ENERGY
PROTOLON(ST) NTSCGEWOEU.../3E Medium Voltage Flexible Cables for Use in Water with Copper Core Shield ENERGY Technical Data Electrical Thermal Type Type designation PROTOLON (ST) NTSCGECEWÖU.../3E Approvals/
More informationGEMSCAB has been associated with marketing and manufacturing of Electric Cables
I NTRODUCTION GEMSCAB has been associated with marketing and manufacturing Electric Cables for over a period 4 decades now. Customer satisfaction has been the prime focus GEMSCAB and today it has established
More informationCRANE, CONVEYOR, LIFT & REELING CABLES
CRANE, CONVEYOR, LIFT & REELING CABLES F-PVC Series... 158 F-TPECY Series...160 P Series...161 PR Series...162 PRRT Series... 164 PRVS Series...166 Reeling/Trailing Cable Enquiry Form...168 P: (09) 264
More informationSubmarine Power Cables
Submarine Power Cables Submarine Power Cables Since decades Nexans plant in Hannover is specialised in the design, production and installation of low and medium voltage submarine power cables required
More informationHigh Voltage Copper, Smooth Aluminum Shield/Sheath
High Voltage Copper, Smooth Aluminum Shield/Sheath XLPE Insulation, HDPE Jacket, 69 kv - 138 kv Features True triple vertical extrusion system for optimum insulation concentricity, and excellent electric
More informationENERGY. TECWATER EMV-FC S1BC4N8-F 0,6/1 kv. Screened Cable for Water Application
ENERGY TECWATER EMV-FC S1BC4N8-F 0,6/1 kv Screened Cable for Water Application Technical Data Trademark Type designation Specification Application TECWATER EMV-FC S1BC4N8-F Design and tests according to
More informationFR-N1X1G1. Low voltage - Energy, cabling, signalling and control
Low voltage - Energy, cabling, signalling and control FR-N1X1G1 Construction: NF C 32-323 NF C 32-323/1 Fire propagation: NF EN 60332-3-24 NF C 32-070 C1 IEC 60332-3-24 C Flame propagation: NF EN 60332-1-2
More informationHigh Voltage Aluminum, Smooth Aluminum Shield/Sheath
High Voltage Aluminum, Smooth Aluminum Shield/Sheath XLPE Insulation, HDPE Jacket, 69 kv - 138 kv Features True triple vertical extrusion system for optimum insulation concentricity, and excellent electric
More informationBFOU 0.6/1kV Power Cable
BFOU 0.6/1kV Power Cable Eland Product Group: ASH APPLICATION A flame resistant, fire retardant, halogen free cable for fixed installation in various electromechanical and electric equipment, emergency
More information14 HH EAC/CTP CE RoHS-II conform
Outer jacket: Pressure extruded PUR mixture Inner jacket: Pressure extruded, gusset filling PUR mixture 12 cores or more: Bundles with optimized pitch length and pitch direction Conductor: Fine-wire strand
More informationQuintas & Quintas Group
Electric Conductors Quintas & Quintas Group Index Quintas & Quintas and Solidal 2 Bare Conductors l uminium Conductors for overhead lines 3 l uminium loy Conductors for overhead lines 4 uminium Conductors
More informationSY PVC / BS EN Control Flexible Cable
SY PVC / BS EN 50525-2-51 Control Flexible Cable Eland Product Group: A5J APPLICATION Used as interconnecting cable for measuring, controlling or regulation in control equipment for assembly and production
More informationData sheet chainflex CF6
1. Outer jacket: Pressure extruded, oil-resistant PVC mixture 2. Overall shield: Extremely bending-stable braid made of tinned copper wires 3. Inner jacket: Pressure extruded, gusset-filling PVC mixture
More informationPRODUCT INFORMATION ÖLFLEX HEAT 125 C MC. Info Improved characteristics in the event of a fire GL - Germanischer Lloyd approved
Electron beam cross-linked cables for more demanding application requirements - halogen free shielded control cable with GL certificate, special fire performance, IEC 60332-3, suitable for +125 C Info
More informationCONTENTS. Introduction Customer Service Product Range Specification and Construction...4-6
CONTENTS PAGE Introduction... 1 Customer Service...2-3 Product Range... 4 Specification and Construction...4-6 Salient Features of Ducab s Design... 7 Installation and Electrical Data...7-19 XLPE Insulated
More informationBS6724 SWA/LSZH Cable IEC /1000V
BS6724 SWA/LSZH Cable IEC 60502 600/1000V Applications: Power cable suitable for power networks, where fire emission of smoke and toxic fumes creates a serious potential threat. Suitable for direct burial.
More informationNA2XSEY 3 x (25-300) mm 2 3.6/6 kv
NA2XSEY 3 x (25-300) mm 2 3.6/6 kv NA2XSEY 3 x (25-300) mm 2 3.6/6 kv (Aluminium, XLPE Insulated, Copper Tape, PVC Sheathed) 25 36.5 1,380 35 39.5 1,620 50 42.0 1,908 70 46.5 2,322 95 50.0 2,781 120 54.0
More informationRFOU 0.6/1kV Power Cable
RFOU 0.6/1kV Power Cable Eland Product Group: ASH APPLICATION A flame retardant halogen free power, control and lighting cable for fixed installation. Suitable for use in all conditions in a marine environment
More informationLISTED. Applications. Features CORDAFLEX (SM) CORDAFLEX (SM)
CORDAFLEX (SM) Portable reel cable EP insulation, dual neoprene jacket with braid reinforcement, 90 C, 600 volts Rack and pinion elevators using sheave guided cables Container crane spreader reels Timber
More informationNYY-J Cable. Dungannon Electrical Wholesale Tel: Page 1 of 10
NYY-J Cable Application: A VDE approved, solid conductor, black PVC jacketed, 600/1kV power and control cable. These power cables are designed for energy supply cable ducts, power station, industry and
More informationXLPE Cable Systems. User s guide. rev. 2
XLPE Cable Systems User s guide rev. 2 C O N T E N T XLPE Cable Systems Page Page Introduction... 3 XLPE cable systems - design, installation and testing... 4 XLPE cables... Cable accessories... Installation
More informationData sheet chainflex CFSOFT1
to 5 x d Highly flexible, soft design PVC outer jacket Oil-resistant Flame retardant 1. Outer jacket: Pressure extruded, oil-resistant PVC mixture 2. Core insulation: Mechanically high-quality TPE mixture
More informationVDE tested single cores according to EN (H05Z-K & H07Z-K) for more demanding requirements
VDE tested single cores according to EN 50525-3-41 (H05Z-K & H07Z-K) for more demanding requirements ÖLFLEX HEAT 125 C MC - halogen free single core with GL certificate, special fire performance, IEC 60332-3,
More informationFTG10OM1-0,6/1KV. 50 N/mm 2 of copper section max for fixed layings
HEPR insulated flexible with braided shield of red copper wires and plastic sheath of halogen-free flame retardant and without emission of corrosive gases. The keeps the electrical characteristics for
More informationBuilding & Infrastructure Cables DELIVERING ENERGY
Building & Infrastructure Cables DELIVERING ENERGY Keystone Cable is a Leading Singaporebased Cable Manufacturer and Supplier. Keystone Cable Market Reach Established since 1990, Keystone Cable has an
More informationData sheet chainflex CF240
1. Outer jacket: Pressure extruded, oil-resistant PVC mixture 2. Overall shield: Aluminum/Polyester tape and extremely bending-resistant braiding made of tinned copper wires. 3. Banding: Plastic foil 4.
More informationData sheet chainflex CF140.UL
1. Outer jacket: Pressure extruded PVC mixture 2. Overall shield: Bending-resistant braiding made of tinned copper wires 3. Inner jacket: Pressure extruded, gusset-filling PVC mixture 4. CFRIP: Tear strip
More informationLIST OF PUBLISHED STANDARDS
Report : 08-0-6 Page o : Of 5 LST OF PUBLSHED STDRDS Total Count: 78 umber SS umber pproved mendment SBS/TC 066 SS 97:07 7.0 Electric cables - mpregnated paper-insulated 07-0-7 metal-sheathed cables for
More informationOFFSHORE WIND FEASIBILITY STUDY APPENDICES Appendix C.2 Subsea Cable Data Sheets
OFFSHORE WIND FEASIBILITY STUDY APPENDICES 10-7 10.3.2 Appendix C.2 Subsea Cable Data Sheets Design data for TFVA 36 kv 3x1x240 mm 2 KQ Metallic Laying up Inner sheath Bedding Armor Diameter of conductor
More informationENERGY. HYDROFIRM(T) EMV-FC S1BC4B-F 0,6/1 kv. Screened Cable for Drinking Water Application KTW/ACS
ENERGY HYDROFIRM(T) EMV-FC S1BC4B-F 0,6/1 kv Screened Cable for Drinking Water Application KTW/ACS Technical Data Trademark Type designation Specification Application HYDROFIRM(T) EMV-FC S1BC4B-F Design
More informationGo to Contents Page BICC. Previous Page Next Page
1 CONTENTS Page Introduction... 1 Customer Service... Product Range... Specification and Construction... 5 Salient Features of Ducab s Design... 6 Installation and Electrical Data... 617 XLPE Insulated
More informationInstallation Devices 4
Installation Devices 4 4.1 Tapes HelaTape Flex - Vinyl Electrical Tapes HelaTape Wrap - Vinyl Tapes HelaTape Shield - Conductive Tapes HelaTape Flex 15 - All Purpose Vinyl Insulating Tape HelaTape Flex
More informationData sheet chainflex CF5
1. Outer jacket: Pressure extruded, gusset-filling, oilresistant PVC mixture 2. Core insulation: Mechanically high-quality TPE or PVC mixture 3. CFRIP: Tear strip for faster cable stripping 4. Conductor:
More informationData sheet chainflex CF210.UL
For detailed overview please see design table 1. Outer jacket: Pressure extruded, oil-resistant PVC mixture 2. Overall shield: Bending-resistant braiding made of tinned copper wires. 3. Banding: Plastic
More informationCONTENTS. Introduction Customer Service Specification...5. Construction...6. Application...6. Technical Data
Content Page CONTENTS Page Introduction... 2 Customer Service... 3-4 Specification...5 Construction...6 Application...6 Technical Data...7-14 1.1 Unarmoured Cables with Overall Screened (TYPE 1)...7 1.2
More information