Westinghouse Molded Case Circuit Breakers Engine Generator FG Amperes
|
|
- Gary Bradley
- 5 years ago
- Views:
Transcription
1 Circuit s FG Amperes Description Page Type FG Three-Pole... 1 Type JG Three-Pole... 3 Type KG Three-Pole... 5 Type G Three-Pole... 7 Type MG Three-Pole... 9 Type NG Three-Pole... 11
2 Cutler-Hammer Dimension Sheet Page 1 Type FG Three-Pole Front View.740 (18.80) Type FG Three-Pole Circuit s FG Amperes (39.67).197(5.00) diameter hole.328(8.33) diameter c'bore 1.938(49.23) deep from top..344(8.74) diameter c'bore.656(16.66) deep from bottom. 4 mounting holes for (No. 8) x 1(M4x0.7x38.10) mounting screws..188(4.78)r.750 (19.05) (35.71) 4 (114.30).375 (9.53).375 (9.53).375 (9.53) On Off.156 R (3.96) R.450(11.43) diameter 6 holes.110(2.8) dia. x.310(7.9) deep, 2 holes accept #6(M3.5) thread cutting screws.819 (20.80) (26.19) (101.60) Side View.125(3.18) x.750(19.05) slots for attachment leads 2.350(59.69) R (44.83).750 (19.05).078 (1.98).094 R (2.39) R.266 (6.76).469 (11.91).625 (15.88) (28.58) (76.20) (85.73) (5.56) wide conductor with.219(5.56) diameter hole [.260 (6.60) diameter hole 175 amp] (152.40) Trough for Attachment eads.750 (19.05).094(2.3) R (Typ.) 4-PC S..172 (4.37).016(.41).125(3.18) x.484 (12.3) deep 6 holes accept #8(M4) thread cutting screws (33.73) (52.40) Push to Trip (104.78) (33.73).687 (17.46) (25.40).344 (8.74).016 (.41) E D B A :.344(8.74) wide x.375(9.53) thick 0 taper, load end 7 taper, line end To top of clip.188 (4.78) (31.75).078(19.81) 2.219(56.36) 2.938(74.63) 3.188(80.98) 3.375(85.73) wide 3(88.90) conductor with.219(5.56) C diameter hole [.250 (6.35) diameter hole 175 amp].313 (7.95) (60.33) (4.78).469 (11.91).469 (11.91).266 (6.76).250(6.35).750(19.05).062(1.57) (39.67).740 (18.80) Reproduced from drawings 1490D63 and 1490D67 Status Dimensions ➀ Measured.125 (3.175) above Escutcheon. ➁ Applied by breaker handle to external handle mechanism. A B C D E Force, bs.➀ On 3.07 (77.98) 2.92 (74.17) 3.96 (100.58) 3.40 (86.36) 3.33 (84.58) 14 (6.35 kgs.) Tripped 2.65 (67.31) 2.57 (65.28) 4.06 (103.12) 2.99 (75.94) 2.98 (75.69) 4➁ (1.81 kgs.) Off 2.08 (52.83) 2.14 (54.36) 4.12 (104.65) 2.42 (61.47) 2.56 (65.02) 16 (7.26 kgs.) Reset 1.98 (50.29) 2.05 (52.07) 4.11 (104.39) 2.30 (58.42) 2.48 (63.10) 21 (9.53 kgs.)
3 Page 2 Circuit s, FG Type FG Three-Pole Front Cover Cutout Drilling Plans Front Connected Rear Connected.250(6.35) R.750(19.05).469 (11.91) (58.75) (73.81) 2 (73.03) (80.16) (48.41) (30.20).594 (15.10).581 (14.76) 4 (114.30) (128.60).188(4.78) ocation of diameter megger holes, if required.688 (17.48) (M4 x 0.7) tap, 4 holes (69.85).438(11.13) diameter holes for 15 to 100 amp.563(14.30) diameter holes for 125 to 150 amp Reproduced from drawings 1490D63 and 1490D67 Cutler-Hammer & Cutler-Hammer Products Five Parkway Center Pittsburgh, Pennsylvania, U.S.A Printed in U.S.A.
4 Cutler-Hammer Dimension Sheet Page 3 Type JG Three-Pole Circuit s JG Amperes Type JG Three-Pole Front View.188 R (4.78) R.781 (19.84).031 (.79) (104.78) (69.85).688 (17.46).688 (17.46).281 (7.14) Dia. 4 Mtg. Holes Dia. C'Bores Side View (103.17) (96.82).812 (20.62).625 (15.88) (65.89) (72.24) (26.19) (37.69) (254.00) (184.15) (211.94).110 (2.79) Dia. 6 Holes.250 R (6.35) R ON/ OFF/.125 (3.18) (101.60) (95.25).250 (6.35) (22.23) (191.29) 15 5 RESET ON OFF TRIP.035 (.89) (26.97).156 (3.96) (147.24) C Typical 3-Pole Thermal-Magnetic Trip Unit.469 (11.91).031 (.79) (22.23).188 (4.78).688 (17.46) Dia. 6 Holes (97.33) (103.17) (109.52) Max (125.81) Max.062(1.57).625(15.88).812(20.62) (53.98) Front Connected Terminals Catalog Cable Amp Wire Torque Number Rating Size T250KB Cu Single #4 to 350 MCM 180 b-in (20.3 Nm) TA250KB Cu-Al Single #4 to 350 MCM 275 b-in (31.1 Nm) 9.38 (23.83) Reproduced from drawings 1491D63 and 1491D67 (25.40)
5 Page 4 Circuit s, JG Type JG Three-Pole Drilling Plans.688 (17.46) (69.85).563 R (14.29) R (69.85).750 (19.05).344 R (8.74) R (39.67).781 (19.84) (184.15) (103.58) C Mounting (M6X1) Tap 4 Holes C Shown in OFF Position (205.59) (124.23) C Rear Connecting Studs.625 (15.88) Dia 6 Holes C Omit 2 Center Holes for 2-Pole s.813 (20.64) (124.23) (205.59).563 R (14.29) R.813 (20.64) C Drawout Support Blocks.375 (9.53) C.438 (11.13) Dia. 4 Holes.250 (6.35).688(17.46).718 (18.24).188 R (4.78) R 3 Megger Holes If Required (100.03) Front Cover Cutout C (74.22) (22.23) C (84.53) (69.85) 3 (88.90) (44.45) (78.59) (46.04) (92.08) (57.15) 1.125(28.58) Mounting Holes Use (M6X1) X 2 (73.025) Pan Head Screw With Sems. Tightening Torque 65 b-in (7.34) Nm. Dia..281 (7.14) Dia (60.33).147 (3.73) 8 Holes Deep to Accept #8 Thread Cutting Screws (122.25).375 (9.53) C of ON/ Contact Position Indicators Red-ON Green-OFF White-TRIP.312 (7.29) Dia..375(9.53).750(19.05) OFF/ C A B D Reproduced from drawings 1491D65 and 1491D67 E F Dimension Status A B C D E F Hdl. Oper. Force On 5.24 (132.10) 5.12 (130.05) 5.54 (140.72) 5.49 (139.45) 4.77 (121.56) 4.72 (119.89) 32 b. (142.3 Nm) Tripped 4.79 (121.67) 4.71 (119.63) 5.10 (129.54) 5.10 (129.54) 4.87 (123.70) 4.85 (123.19) Off 4.02 (102.11) 4.06 (103.12) 4.33 (109.82) 4.45 (113.03) 4.91 (124.71) 4.95 (125.73) 22 b. (97.9 Nm) Reset 3.91 (99.31) 3.96 (100.58) 4.21 (106.93) 4.36 (110.74) 4.90 (124.46) 4.95 (125.73) 38 b. (169.0 Nm) Cutler-Hammer & Cutler-Hammer Products Five Parkway Center Pittsburgh, Pennsylvania, U.S.A Printed in U.S.A.
6 Cutler-Hammer Dimension Sheet Page 5 Type KG Three-Pole Circuit s KG Amperes Type KG Three-Pole Front View.625 (15.88) 6 Holes 5.490(139.43) (87.32).110 (2.79) Dia. x.297 (7.54) Deep, 4 Holes Accept #6 (M3) Thread Cutting Screws Side View (109.55).844 (21.44) (112.70) (31.75) (65.10) (9.52).375 (9.52) Contact Position Indicators Red/1 - On Green/O - Off White - Trip.250 R (6.35) R.063 (1.60).093 R (2.36) R.750 (19.05).860 (21.84) (52.39) (104.78) (60.73) (30.96) (41.28).188 (4.77) R ON (61.89) OFF (41.28).125 (3.18) (101.60) (90.50) (71.45).250 (6.35).625 (15.88) (214.33) 8 (225.43) (257.18) Trough for Attachment eads.188 (4.77) Dia. C'Bore x.031 (.79) DP.147 (12.7) Dia. Hole x DP to Accept #8 (M4) Thread Cutting Screws (8 Places).125 (3.18) Wide x.750 (19.05) Slots for Attachment eads C D C B A 3 R (98.42) R (96.85).062 (1.57) (27.00).188 (4.77) (44.04).694 (17.63) (25.40) (5.31) 5.000(127.00) (146.46) 5.966(151.54).188 R (4.77) R 4.782(121.46) (13.89) (17.73) (29.49).937 (23.80) Dimensions for Extended Terminals and Barrier Style Nos. 4212B60G02, 4212B61G02 and 1492D24H01 (22.25).438 (11.13).063 (1.60).250 (6.35) R.281 (7.14) Dia. Mounting Holes 4 Holes for (M6) x 1.50 (38) Mounting Screws Dia. C'Bore from Top 2 (73.03) Deep (66.68) Deep.438 (11.13) Dia C'Bore.750 (10.05) Deep from Bottom (103.17) E F.062 (1.57) (96.82).188 (4.77) (27.00).750 (19.05) Wide Conductor with.391 (9.93) Dia Hole ine and (60.33) Dimensions Status A B C D E F Force➀ On lbs. (136.9) (132.1) (144.5) (142.5) (119.9) (121.2) (13.61 kgs.) Tripped (121.2) (119.1) (129.0) (129.8) (124.2) (124.2) Off lbs. (105.7) (106.9) (113.3) (117.9) (125.7) (124.7) (11.34 kgs.) Reset lbs. (103.4) (105.2) (116.1) (115.8) (125.7) (124.5) (15.87 kgs.).766 (19.46) ➀ All handle forces measured approximately (3.17) from top of handle. Reproduced from drawings 1492D64 and 1492D68
7 Page 6 Circuit s, KG Type KG Three-Pole Rear Connected Studs Front Connected Terminals Front Cover Cutout.844 (21.44).344 R (8.74) R (22.23) Dia. (6 Places) (Omit 2 Center Holes for 2-Pole) C (130.58) 8 (225.42) C (125.02) (214.33).188 R (4.77) R C.828 (21.03) (95.25) (41.66) (31.75) (94.84) (M6) 4 Holes.859 (21.83) (89.31) (66.68) (121.46) (33.34) (60.73) R (22.22) R ON OFF.562 (14.27) C (25.39).625 (15.87).625 (15.87) (25.39) (94.82) (130.62) 8 (225.34) (151.15) 10 (206.60).313 (7.93).625 (15.87) (43.64) (87.28) (43.64).859 (21.82) (130.52) 8 (130.22) (94.32).688 (17.46) 3.375(85.69) 5.250(133.30) 9.688(245.97) 3.375(85.69).281 R (7.14) R.438 (11.11) Dia. 4 Holes for.312 (7.92) Mtg. Bolts (112.67) (43.64) Reproduced from drawings 1492D63 and 1492D67 Cutler-Hammer & Cutler-Hammer Products Five Parkway Center Pittsburgh, Pennsylvania, U.S.A Printed in U.S.A.
8 Cutler-Hammer Dimension Sheet Page 7 Type G Three-Pole Circuit s G Amperes Type G Three-Pole Front View Side View.250 (6.35.) 20 Tap.406 (10.31) (6) Holes.313 (7.93) (104.73) (52.37).125 (3.17).313 (7.93) Deep Accepts #6 Thread Cutting (22.22).438 (11.11) (109.49) (96.80).906 (23.01) Saf-T-Vue Cover When Included.531 (13.49) 1 (47.61) (133.30) (85.69) (29.36) (28.56) (60.30) (1.59) (242.00) (76.96) ON (142.82) (272.94) (173.76) (332.45) 1 Automatic Tripped (70.62) ON (85.69) R (51.18) (1.59) 1 (47.61) (30.15) (44.43) (78.55) (243.59) (80.14) (113.46) MAGNETIC TRIP OFF PUSH TO TRIP Test Points RATING PUG (142.82) (158.69) 15 Reset Max OFF.250 (6.35).094 (2.38) Rod (30.94).063 (1.59) (15.08) (44.43) 4 (114.26).313 (7.93).063 (1.59) (104.73) (30.94) (209.47) (61.89) (46.23).313 (7.93) Mounting Holes.531 (131.49) Counterbore (4 Holes).891 (22.61).438 (11.11) Thick 1 Taper Both Sides (39.67) Wide.531 (13.49) (64.27) (103.15) (28.56).938 (23.80).688 (17.46) (29.36) (22.22) (101.60) (203.52) 5 Current Carrying Parts Omitted From Center Pole for 2-Pole Reproduced from drawing 2608D92
9 Page 8 Circuit s, G Type G Three-Pole Drilling Plans For Mounting Bolts (Front Connected Terminals) For Rear Connected Studs (Insulated Panel) For Plug-In Block Front Cover Cutout.250 (6.35) 20 Tap.313 (7.93) (4 Holes) C of (128.54) (242.00) (113.46) 5 C of (129.33) 4 (114.26) (242.54) (26.98) Hole for 300 to Holes for 3-Pole 4 Holes for 2-Pole Omit 2 Center Holes for 2-Pole (30.15) Radius 5 C of Studs C of C of (44.43) (28.56) (129.33) 4 (114.26) (243.59) (300.71) Cutout for Saf T Vue Cover (If required) (49.99) (44.43) (49.99) (190.43) 3 (123.78) (66.65) C of C of.250 (6.35) (44.43) (50.78) 4 (114.26) C of C of (25.39) C of Studs (28.56) (6 Holes) for.375 (9.52) Mounting Bolts ocation for.313 (7.93) Megger Holes (If required) (4443.) (177.73) Rear Connected Studs.438 (11.11) A Plug-In- Adapter Kit Terminal Arrangements Copper Cable Only (Must be Ordered Separately) Cat. #TA600A Wire Size (2) MCM Optional A/CU Cable (Must be Ordered Separately) Cat. #TA600A Wire Size (2) MCM Do Not Use More Than 25 Ft. bs. Torque to Tighten Nuts Do not Use More Than 25 Ft. bs. Torque to Tighten Nuts Ampere Style Thread Dimension Rating Number Size A 300 to C960G / to C960G / to C960G / 32 Poles Ampere Kit Style Thread Rating Number Size to C644G to C644G Reproduced from drawing 2608D93 Cutler-Hammer & Cutler-Hammer Products Five Parkway Center Pittsburgh, Pennsylvania, U.S.A Printed in U.S.A.
10 Cutler-Hammer Dimension Sheet Page 9 Type MG Three-Pole Front View Type MG Three-Pole Side View Circuit s MG Amperes.344 (8.73) Mounting Hole.703 (17.85) Counterbore (4) Holes 5-13 Tap Removable oad End Terminal Cover Clearance to Arc Barrier (78.55) 1.031(26.18).734(18.65).719(18.25) 1.313(33.32).531(13.49).250(6.35) See Figures 1, 2 and Table (71.01) 3.00 (76.17) (406.24) 9.250(234.86) (374.50) 8.625(218.99) 1 (47.61) (206.29) (349.11) 19.5 On - 13 Tap 1 Auto Trip 3 R (98.39) R.594(15.08) (55.54).766(19.44) (28.56) (177.73).406(10.31) (10.31) Minimum (291.99) B 5.750(145.99) Test Points (95.21) (77.76) (71.01) 15 Reset Maximum 11.5 Off.438 (11.11) Thick 1 Taper Each Side (15.08).344(8.73) (28.56) (114.26) Terminal Block Assembly Used Only on Ground Fault s.703(17.85) 1.188(30.15) (26.18) (53.95) 8.250(209.47) (77.76) (38.88) 4.125(104.73) 1.781(45.23).891(22.61) 1.125(28.56) (60.30) Removable oad End Terminal Cover 3.813(96.80) 4.063(103.15) 4(123.78) 6.063(153.93) 1.125(28.56).531(13.49).734(18.65) 1.031(26.18) Forces (From End of ) On 50 lbs. (22.68 kgs.) Off 24 lbs. (10.89 kgs.) Reset 60 lbs. (27.22 kgs.) (22.22) 2.250(57.13) (76.17) (222.16) (161.86) (85.69) (66.65) Current Carrying Parts are Omitted From Center Pole for 2 Pole Reproduced from drawing 2605D21
11 Page 10 Circuit s, Type MG Three-Pole MG Amperes For Mounting Block (Front Connected Terminals) C of C of (218.99) (155.51) (374.50) For Rear Connected Studs 5 C of C of 7.00 (177.73) 11 (291.99) 4 (114.26) For Plug-In Adapter Kit (25.39) (209.47) C of (177.73) C of 11 (291.99) (374.50) 4 (114.26) (25.79) Front Cover Cutout (6)Holes for.375(9.52) MountingBolts.250(6.35) Radius (24.60) (52.76) (82.52).188(4.76) Radius C of 3 (88.87) (117.73) C of.375(9.52) (4)Holes.813(20.63)Hole for 250Ampsto400Amps 6 Holes for 3 Pole 4 Holes for 2 Pole (26.98) Radius 1.063(26.98)Hole for 450Ampsto600Amps Omit 2 Center Holes for 2 Pole 1.188(30.15)Hole for 700Ampsto800Amps Front Connected Terminals (Must be Ordered Separately) Amp Catalog Wire Size Rating Number Number of Cables For Al/Cu Cable 600 TA700MA1 (2) #1-500 MCM 800 TA800MA2 (3) 3/0-400 MCM For Copper Cable 600 T600MA1 (2) 2/0-500 MCM 800 T800MA1 (3) 3/0-300 MCM Rear Connected Studs 2 Required Per Pole (Not Supplied With ) Stud Ampere Stud Style Thread Dimension Rating Number Size A C960G04 3 / / C960G05 3 / / C960G06 3 / / C960G / C960G / C960G / C960G / / C960G / / C960G / / 32 Plug-In Adapter Kit 1 Kit Per (Not Supplied With ) Poles Ampere Kit Style Thread Fig. Rating Number Size C644G / C644G / C544G / C544G / (7.93) (22.22) Panel.313 (7.93) GROUND FAUT TRIP TIME IN SECONDS PICK UP AMPERES MAGNETIC TRIP PUSH TO TRIP RATING PUG (48.40) BREAKER TEST GROUND FAUT TEST.453 (11.50) Nameplate (Used With Ground Fault Trip) Reproduced from drawing 260D (16.66).656 (16.66).438 (11.11) A Figure 1 Do Not Use More Than 25 Ft. bs. Torque To Tighten Nuts Figure 2 Cutler-Hammer & Cutler-Hammer Products Five Parkway Center Pittsburgh, Pennsylvania, U.S.A Printed in U.S.A.
12 Cutler-Hammer Dimension Sheet Page 11 Type NG Three-Pole Circuit s NG Amperes Type NG Three-Pole Front View Side View Bolted Rear Connected Studs (104.73) (26.98).531 (13.49) (209.47) - 13 Tap Removable Terminal Cover.703 (17.85) (182.49) (152.34) (29.36).359 (9.12).734 (18.65) (36.50).594 D (15.08) D.344 D (8.73) D 1 Inch Thick (Minimum) Insulated Panel (0.79) (71.01) (58.71) (157.10) (406.24) 9.250(234.86) (374.50) 8.625(218.99) B 5.625(142.82) Terminal Block Assembly Used Only On Ground Fault s (77.76) (38.88).703 (17.85) 1(47.61) (206.29) (95.21) (349.11) (77.76) (71.01) 19 30' On 15 Reset Maximum 11 30' Off Removable Terminal Cover 1 Auto. Trip.438(11.11) Wide 1 Taper on Each Side.063 (1.59).156 (3.97).531 (13.49) (84.90) (1.59) R (97.59) R (3.97) (131.71).719 (18.25) (29.36) C of (29.36) (17.85) (36.10) (78.55) (177.73) (58.71) 11 (291.99) Outside Poles (Stud Style Number 373B375G04) 1.250(31.74)- 12 Threads Center Pole (Stud Style Number 373B375G03) Omit for 2-Pole (266.60) (30.15) Front Connected Terminals (Must be Ordered Separately) (53.95).531 (13.49) Current Carrying Parts are Omitted From Center Pole for 2-Pole (25.79) (28.56) (57.13) (51.57) Amp Catalog Wire Size Rating Number Number of Cables For Al/Cu Cable 1000 TA1000NB1 (3) 3/0-400 MCM 1200 TA1200NB1 (4) 4/0-500 MCM B 2 Terminal Unit 13 / 16 3 Terminal Unit 1 9 / 16
13 Page 12 Circuit s, Type NG Three-Pole NG Amperes Drilling Plans For Mounting Bolts For Rear Connected Studs (Insulated Panel) Front Cover Cutout 0.375(9.52) Dia. (4) Holes or.313(7.93)- 18 Tap C of (218.99) (374.50) Omit Holes in Center Pole for 2-Pole C of (177.73) 11 (291.99) (49.99) (152.74) (52.76) (82.52) C of R (6.35 R) C of R (4.76 R) C of Amp Rating C of Hole Dia. 3 (88.87) (203.12) / / 16 Cutler-Hammer & Cutler-Hammer Products Five Parkway Center Pittsburgh, Pennsylvania, U.S.A Printed in U.S.A.
Series C, F-frame molded case circuit breaker, 15A, Two-pole, Thermal Magnetic Trip, FD Breaker
FD2015 2 Pole 15A FD Eaton Corp Catalog Number Manufacturer Description Weight per unit Product Category Features amperage rating 15 Frame Size F-frame interrupt rating 35 kaic at 480V Poles 2 Trip Type
More informationSeries C, F-frame molded case circuit breaker, 125A, Three-pole, Thermal magnetic trip. Thermal magnetic
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 HFD3125 HFD3125 125A 3P CKT BRKR Eaton Corp Catalog Number Manufacturer Description Weight per unit Product Category Features
More informationInstallation Instructions for JDB, JD, HJD, JDC, JW HJW, JWC Circuit Breakers and Molded Case Switches
Installation Instructions for JDB, JD, HJD, JDC, JW HJW, JWC Circuit Breakers and Molded Case Switches WARNING DO NOT ATTEMPT TO INSTALL OR PERFORM MAINTENANCE ON EQUIPMENT WHILE IT IS ENER- GIZED. DEATH,
More informationPVGard 600 and 1000 Vdc solar photovoltaic circuit breakers
Supersedes October 2013 photovoltaic circuit breakers Contents Description Page Product description........................ 1 PVGard 600 Vdc........................... 2 Technical data...........................
More informationBULLETIN 140U. Molded Case Circuit Breakers SELECTION GUIDE
BULLETIN 140U SELECTION GUIDE Product Overview Bulletin 140U 15 1200 A Thermal-Magnetic 15 800 A Electronic 70 1200 A LS Long Time/Short Time LSI Long Time/Short Time/High Instantaneous LSG Long Time/Short
More informationPage 2 DS LOW VOLTAGE POWER CIRCUIT BREAKERS Digitrip Trip Unit Inside Wiring Guide Outside Wiring Guide Shutter Drawout Unit Position Indicator Escut
Page 1 Supersedes Renewal Parts Data 33-790-1G pages 1-20 dated December, 1988 Mailed to: C, D, E/33-700 Westinghouse DS and DSL Low Voltage Power Circuit Breakers and Cell Parts Contents Pages DS Breaker
More informationInterrupting Capacity (Symmetrical Amperes) Volts ac (50/60 Hz) Y/ ,000 25,000. Frame Only E2L3600F
-220 Mining Service Circuit s Table -395. Interrupting Capacity Ratings Circuit Interrupting Capacity (Symmetrical Amperes) Volts ac (50/60 Hz) Volts dc 240 480 1000Y/577 250 E 2 L E 2 LM 65,000 35,000
More informationT CLASS T FUSE BLOCKS
Ferraz Shawmut Fuse Blocks accommodate fuses up to 600A. Insulators are either of durable, glassfilled polycarbonate (GFPC) or phenolic with verified dielectric strength in excess of 2500V. Ferraz Shawmut
More informationInstallation Instructions for NW, HNW, and NWC Circuit Breakers and N-frame Series C Molded Case Switches
Installation Instructions for NW, HNW, and NWC Circuit Breakers and N-frame Series C Molded Case Switches WARNING DO NOT ATTEMPT TO INSTALL OR PERFORM MAINTENANCE ON EQUIPMENT WHILE IT IS ENER- GIZED.
More informationCutler-Hammer. Installation Instructions for Undervoltage Release Mechanism (Handle Reset) with LED for E 2 L and E 2 LM Mining Circuit Breakers
Cutler-Hammer Installation Instructions for Undervoltage Release Mechanism (Handle Reset) with LED for E 2 L and E 2 LM Mining Circuit Breakers CONTACT WITH ENERGIZED EQUIPMENT CAN RESULT IN DEATH, SEVERE
More informationInstallation Instructions for KPS and KPH Circuit Breakers and Molded Case Switches
Instruction Leaflet IL 0106001E Contents Description Page Introduction.......................... Installation............................ Manual Operation and Thermal Magnetic Trip Unit Adjustment.......................
More informationQ and M-Frame Circuit Breakers Instruciton Leaflet for Alarm Switch and Auxiliary Switch Combinaiton
Bul. 140U Q and M-Frame Circuit Breakers Instruciton Leaflet for Alarm Switch and Auxiliary Switch Combinaiton! WARNING CONTACT WITH ENERGIZED EQUIPMENT CAN RESULT IN DEATH, SEVERE PERSONAL INJURY, OR
More informationInstruction Bulletin. DS/DSL and DSII/DSLII Low Voltage Power Circuit Breaker Replacement Parts Class 6035
Instruction Bulletin 4402-997-0 February 999 Middletown, OH, USA DS/DSL and DSII/DSLII Low Voltage Power Circuit Breaker Replacement Parts Class 605 DS/DSL and DSII/DSLII Low Voltage Power Circuit Breaker
More informationCircuit Breakers Naval Shipboard Use
Circuit Breakers Naval Shipboard Use Circuit Breakers for Naval Shipboard Use Contents Description Page Description Page Description Page Description Page Selector Guide for Navy Circuit Breakers......
More information2.2. Molded Case Circuit Breakers. Contents. NG-Frame ( Amperes) Series G
. NG-Frame (00 ) NG-Frame (30 00 s) Product All Eaton NG-Frame circuit breakers are suitable for reverse feed use All NG-Frame circuit breakers are HACR rated Contents Page EG-Frame (5 5 s)..................
More informationI.L. 29C184A File WARNING
CONTACT WITH ENERGIZED EQUIPMENT CAN RESULT IN DEATH, SEVERE PERSONAL INJURY, OR SUBSTANTIAL PROPERTY DAMAGE. DO NOT ATTEMPT TO INSTALL OR PERFORM MAINTENANCE ON EQUIPMENT WHILE IT IS ENER- GIZED. ALWAYS
More informationCutler-Hammer I.L. 29C160G WARNING NOTICE 1-0 INTRODUCTION. General Information
Cutler-Hammer Installation Instructions for Undervoltage Release Mechanism (Handle Reset) for EHD, FDB, FD, HFD, FDC, FW, HFW, FWC Circuit Breakers and Molded Case Switches WARNING DO NOT ATTEMPT TO INSTALL
More informationMOLDED CASE CIRCUIT BREAKERS
EB -, -, -Poles; Volts AC ; Thermal Magnetic and Saf-T-Vue at C 5 0 5 0 5 EHB -, -, -Poles; 4 Volts AC ; Thermal Magnetic and Saf-T-Vue at C 5 0 5 0 5 -Pole, 77 Volts AC, 5 Volts DC➊ Underwriters Laboratories,
More informationInstallation Instructions for Type SM Safety Handle Mechanism for L-Frame Series C Circuit Breakers and Molded Case Switches
I.L. 29C284B File 29-000 Installation Instructions for Type SM Safety Handle Mechanism for L-Frame Series C Circuit Breakers and Molded Case Switches DO NOT ATTEMPT TO INSTALL OR PERFORM MAINTENANCE ON
More informationEngine Generator Circuit Breakers
Engine Generator Circuit Breakers Product Description............................................. 2 Application Description........................................... 2 Standards and Certifications......................................
More informationRENEWAL PARTS AK-2-15 AK-2-25 AK-3-25 AKF-2-25 AK-2A-15 AK-2A-25 AK-3A-25 AKF-2A-25 AKU-2-25 AKU-3-25 AKU-2A-25 AKU-3A-25
Data ubject to change without notice. RENEWAL PARTS POWER CIRCUIT BREAKERS TYPES 225 AMP FRAME SIZE 00 AMP FRAME SIZE GEF-449G Supersedes GEF-449F AK-2-5 AK-2-25 AK-3-25 AKF-2-25 AK-2A-5 AK-2A-25 AK-3A-25
More informationR6F30A1S R6F30A1S 1P 60A 600V Fuse BLK. Features. Long Description
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 Catalog Number Manufacturer Description Weight per unit Product Category Features Clip Type Fuse Current Rating Fuse Type
More informationPOWER TERMINAL BLOCKS
Terminal Blocks and Wiring Systems Catalogs > Industrial Controls Catalog > Terminal Blocks and Wiring Systems > Power Terminal Blocks POWER TERMINAL BLOCKS Introduction Standards Compliance High Fault
More information2.3. Molded Case Circuit Breakers. Series C. Accessories Selection Guide and Ordering Information
Molded Case Circuit s Series C.3 Accessories Selection Guide and Ordering Information Line and load terminals provide wire connecting capabilities for specific ranges of continuous current ratings and
More informationQ and M-Frame Circuit Breaker Instruction Leaflet for Installation and Operation for Thermal Magnetic Trip Units
Q and M-Frame Circuit Breaker Instruction Leaflet for Installation and Operation for Thermal Magnetic Trip Units Bul. 140U DO NOT ATTEMPT TO INSTALL OR PERFORM MAINTENANCE ON EQUIPMENT WHILE ITS IS ENERGIZED.
More informationClass H & K Fuse Holders - 250/600 Volt
Class H & K - 250/0 Volt Specifications: Approved for 10,000 Amp Withstand Rating and Short Circuit Current Ratings (SCCR) UL Listed File No. IZLT.E35113 CSA Certified File No. LR21455 RoHS Compliant &
More informationA WARNING. Installation Instructions for KD, HKD, KDC, CKD, CHKD Circuit Breakers I.L. 29C092C
Installation Instructions for KD, HKD, KDC, CKD, CHKD Circuit Breakers with Digitrip OPTIM Trip Unit and Powernet and/or Zone Interlock A WARNING CONTACT WITH ENERGIZED EQUIPMENT CAN RESULT IN DEATH, SEVERE
More informationMOULDED CASE CIRCUIT BREAKERS 16A TO 630A
TEMBREAK 2 MOULDED CASE CIRCUIT BREAKERS 16A TO 630A 1. Welcome to TemBreak 2 2. Ratings and Specifications 3. Operating Characteristics 4. Application Data 5. Accessories 6. Installation 7. Dimensions*
More informationCutler-Hammer. Installation Instructions for the Digitrip OPTIM Pole Trip Unit Installation and Operation with L-Frame Series C Circuit Breakers
Cutler-Hammer Installation Instructions for the Digitrip OPTIM 550 3-Pole Trip Unit Installation and Operation with L-Frame Series C Circuit Breakers Table of Contents Description Page 1.0 General Information......................1
More informationCutler-Hammer. Installation Instructions for the ND OPTIM 550 PowerNet and/or Zone Interlock Accessories (ICK 550N, ZGK550N, ZGPK550N) I.L.
Cutler-Hammer Installation Instructions for the ND OPTIM 550 PowerNet and/or Zone Interlock Accessories (ICK 550N, ZGK550N, ZGPK550N)! WARNING CONTACT WITH ENERGIZED EQUIPMENT CAN RESULT IN DEATH, SEVERE
More informationInstallation Instructions for TMQV Circuit Breakers and Molded Case Switches
DEH41188 Installation Instrucitons Contents Description Introduction............................. Installation.............................. Manual Operation........................ Inspection and Field
More informationLighting and Power Distribution Panelboards
EXPLOSIONPROOf Lighting and Power Distribution Panelboards The design offers sufficient gutter space on sides to allow through wiring and easy lug connection. All enclosures are furnished with hinges,
More information2.3. Molded Case Circuit Breakers. Contents. Internal Accessories. Series C. Product Overview. Description
Molded Case Circuit s Series C.3 Series C Internal Accessories Contents Description Product Overview.......................... Standards and Certifications.................. Quick Reference...........................
More informationBulletin 1494V Variable Depth, Flange Operated Disconnect Switch Kits for 400 and 600 Amperes (Series A) Switches
Bulletin 494V Variable Depth, Flange Operated Disconnect Switch Kits for and Amperes (Series A) Switches ATTENTION: To prevent electrical shock, disconnect from power source before installing or servicing.
More informationInstallation Instructions for R-Frame Circuit Breakers and Molded Case Switches
Instruction Leaflet IL29C107N Effective January 2012 Supersedes IL29C107M 8/11 Installation Instructions for R-Frame Contents Description Page 1. Introduction........................... 2 2. Installation............................
More informationN-frame Circuit Breaker
Bul. 140U N-Frame Circuti Breakers Instruction Leaflet for N-Frame Circuit Breakers WARNING DO NOT ATTEMPT TO INSTALL OR PERFORM MAIN- TENANCE ON EQUIPMENT WHILE ENERGIZED. DEATH, SEVERE PERSONAL INJURY,
More informationAPPENDIX E. Electrical System Single Line Diagram Overcurrent Protection Study Overcurrent Protection Device Specifications
Student Resource Building University of California Santa Barbara Clement Fung Lighting Electrical Option APPENDIX E Electrical System Single Line Diagram Overcurrent Protection Study Overcurrent Protection
More informationwww. ElectricalPartManuals. com Digitrip Retrofit System for Allis-Chalmers LA-4000 F Fused Breakers IL 33-A1K-1 WARNING
SAFETY PRECAUTIONS WARNING POWER CIRCUIT BREAKERS ARE EQUIPPED WITH HIGH SPEED, HIGH ENERGY OPERATING MECHANISMS. THE BREAKERS AND THEIR ENCLOSURES ARE DESIGNED WITH SEVERAL BUILT-IN INTERLOCKS AND SAFETY
More informationMagnetic Overload Relays
Magnetic Overload Relays Series N147 Series N147 Overload Relays are of the magnetically operated self reset type, designed for use on or motor starters and controllers for Navy Service A applications.
More informationDesign Guide for Integration of Fixed-Mount Circuit Breakers
Design Guide Design Guide for Integration of Fixed-Mount Circuit Breakers WL Low Voltage Power Circuit Breakers www.usa.siemens.com/wlbreaker Contents Introduction... 3 Mounting... 3 Mounting Surface...
More information15-I73E CAT REF.
& www.terasaki.co.jp 5-I7E CAT REF. TABLE OF CONTENTS General - Introduction - General - Selection Chart - Ratings and Specifications - Air Circuit Breakers for DC50V-00V - Moulded Case Circuit Breakers
More informationVL Circuit Breaker Features & Benefits. powerful ideas RELIABLE SOLUTIONS
VL Circuit Breaker Features & Benefits powerful ideas RELIABLE SOLUTIONS A Solutions Oriented Circuit Protection Family The Tangram An ancient Chinese game in which a few simple components provide endless
More informationsection-page Table 1. Transfer switching device ratings. Conditional short circuit current
Operator s Manual 7000 Series ATS Automatic Transfer Switching Equipment D design 30 through 200 amperes TABLE OF CONTENTS section-page INSTALLATION... 1-1 Enclosures and Mounting... 1-1 Power Connections...
More information14-I73E CAT REF.
& www.terasaki.co.jp -I7E CAT REF. TABLE OF CONTENTS General - Introduction - General - Selection Chart - Ratings and Specifications - Air Circuit Breakers for DC50V-00V - Moulded Case Circuit Breakers
More informationInstallation Instructions
Installation Instructions Bulletin 1494V Variable Depth, Flange Operated Circuit Breaker Operating Mechanisms For use with Circuit Breakers 140G-G, 140MG-G, 140G-H, 140MG-H, 140G-I, 140MG-I, 140G-J, 140MG-J,
More informationGears & Fuse Gears. American General Purpose Fuses Cylindrical & Blade Fuse Blocks Class H, K & R CLASS H, K AND R FUSE BLOCKS. Ratings.
Ratings Ferraz Shawmut Class H, K and R Fuse Blocks accommodate all Class H, K and R 250 and 600V power fuses. A choice of screw, pressure plate, box and special order stud connectors fit a wide range
More informationLH600303C 1/10-30A 3P 600V Class H Box Lug Fuse Block
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 LH600303C 1/10-30A 3P 600V Class H Box Lug Fuse Block Littelfuse Catalog Number LH600303C Manufacturer Littelfuse Description
More informationFrame Sizes: AKJ/ AKJT I AKJU-50 and AKR/ AKRU-30/ 50, AKRT-50
RENEWAL PARTS LOW VOLTAGE POWER CIRCUIT BREAKERS Frame Sizes: AKJ/ AKJT I AKJU-50 and AKR/ AKRU-30/ 50, AKRT-50 GEF-4527F Supersedes GEF-4527E TABLE A. INDEX OF BREAKER MODELS COVERED BY THIS PUBLICATION
More informationa WARNING Allen-Bradley Parts K-Frame Circuit Breaker Instruction Leaflet for Alarm Switch and Alarm /Auxiliary Switch Combination Bul.
K-Frame Circuit Breaker Instruction Leaflet for Alarm Switch and Alarm /Auxiliary Switch Combination Bul. 140U a WARNING DO NOT ATTEMPT TO INSTALL OR PERFORM MAIN- TENANCE ON EQUIPMENT WHILE IT IS ENERGIZED.
More informationSECTION PANELBOARDS
SECTION 16470 PANELBOARDS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. The general provisions of the contract including General and Special Conditions and General Requirements shall apply to all work under
More informationBulletin 1494F Fixed-Depth Flange-Mounted Disconnect Switches. Selection Guide
F Fixed-Depth Flange-Mounted Disconnect Switches Selection Guide F Fixed-Depth Flange-Mounted Disconnect Switches Product Cat. No. 1494F-N Disconnect Switch with Cat. No. 1494F-F Fuse Block Adapter Plate
More informationMulti-Pak Group Control
Multi-Pak Grouping.1 Product....................................... Application.................................... Features Enclosures........................................... V-T-2 V-T-2 V-T-2 Feeder
More information25.4. Molded Case Circuit Breakers. For Immediate Delivery or Tech Support call KMParts.com at (866) Contents
.4 Molded Case Circuit Breakers Gi-, Fi, Ji-, Ki-, Li-Frames Molded Case Circuit Breaker Family Molded Case Circuit Breakers When higher interrupting ratings are not required. Product Overview Gi-, Fi,
More informationBulletin 1494V Variable Depth Disconnect Switch Installation Instructions (Cat 1494V-DS400; -DSX400 - Series D)
Bulletin 494V Variable Depth Disconnect Switch Installation Instructions (Cat 494V-DS400; -DSX400 - Series D) ATTENTION: To prevent electrical shock, disconnect from power source before installing or servicing.
More informationInterchangeable Built-in Fixed thermal Adjustable thermal Magnetic Fixed Adjustable Adjustable Electronic RMS 7 LS LSI
. Technical Data and Specifications Ratings Frames EG, JG and LG EG JG LG Maximum rated current (amperes) 15, 160 1 50 400, 630 Breaker type 3 B B E S S H H C E S H C U X E S H C U X of poles 1, 3, 4,
More informationwww. ElectricalPartManuals. com Type AM Magne-Biast Circuit Breakers RENEWAL PARTS
RENEWAL PARTS Ordering Instructions 1. Always specify the complete nameplate data of the breaker. 2. Specify the quantity, catalog number (if listed), reference number (if listed) description, and this
More informationAllen-Bradley HP Inverting Fault Circuit Breaker Kit
Allen-Bradley 1397 400-600HP Inverting Fault Circuit Breaker Kit Cat. Nos. 1397-IFB600 What This Option Provides This option is intended to be applied to regenerative 1397 drives with high inertia loads.
More informationUNIVERSITY OF WASHINGTON Facilities Services Design Guide. Electrical. Switchboards. Basis of Design. Design Evaluation
Basis of Design This section applies to the design relating to low voltage switchboards. Design Criteria UW Class N1 facilities main switchboards shall be rear accessible. The main, tie and feeder breakers
More informationUL 489/CSA C22.2 No. 5 Listed C60 Circuit Breakers 1.22 [31.1] 1.77 [45.1] 4.86 [123.4] Clearance 1.77 [45]
Multi 9 System Catalog UL 489/CSA C22.2 No. 5 Listed C60 Circuit Breakers Figure 46: UL 489/CSA C22.2 No.5 Listed C60 240 Vac Circuit Breaker with Box Lug Terminals Figure 47: UL 489/CSA C22.2 No.5 Listed
More informationOpen-Style Power Distribution Blocks
I MPDB Series Open-Style Power Distribution Blocks The Next Generation Power Distribution Block (PDB) Ratings: Volts: 1000Vac/DC Amps: 65 to 2260A based on NEC table 310.15(B)(16) 75ºC ampacities Mersen
More informationTypes ALB-1 and NLB-1
Types ALB- and NLB- ircuit Breakers for Naval Shipboard Use Types ALB- and NLB- Breakers 5 Volts ac and dc, 50 Amperes Maximum, 5000 Amperes I.. Interrupting Rating 0 50 ampere units: 5,000 amperes ac
More informationVacClad-W type VCP-W 5 and 15 kv, 36-inch-wide switchgear components
Supersedes July 2002 Contents Page Procedure for identifying parts... 2 Customer ordering instructions.... 2 Distributor ordering instructions.... 2 Front panel components.... 3 Breaker pan assembly....
More informationCutler-Hammer Molded Case Circuit Breakers Amperes. January 2001 Vol. 1, Ref. No. [0477] G-Frame
Cutler-Hammer January 200 Vol., Ref. No. [077] s Molded Case s 5-00 Amperes 2- 2-2 Product Line Overview January 200 Vol., Ref. No. [068] 2 Product Line Description Cutler-Hammer Molded Case s are designed
More informationDEF 005. WavePro Power Circuit Breakers A Frames, Vac. Renewal Parts
g DEF 005 WavePro Power Circuit Breakers 3200 5000 A Frames, 240 600 Vac Introduction This guide contains a listing of the parts and assemblies that are available as replacement parts for WavePro 3200
More informationBulletin 1494C Cable Operated Disconnect Switch Kit (600A) Installation Instructions (Cat 1494C- _ Series 2 : 600A)
Bulletin 494C Cable Operated Disconnect Switch Kit (600A) Installation Instructions (Cat 494C- _ Series : 600A) ATTENTION: To prevent electrical shock, disconnect from power source before installing or
More informationCH120CAFPN 1P 20A 120 Combo Arc Fault PN Breaker
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-794 Fax: 936-560-4685 CH20CAFPN P 20A 20 Combo Arc Fault PN Breaker Eaton Corp Catalog Number Manufacturer Description Weight per unit Product
More informationFACTORY SEALED CIRCUIT BREAKER PANELBOARDS
FACTORY SEALED CIRCUIT BREAKER BOARDS Applications Hazardous areas due to the potential of explosive gas atmospheres, combustible dusts or easily ignited fibers or flyings and areas subjected to corrosive
More informationIndustrial Generator Set Accessories. Standard Features. Line Circuit Breakers kw
Industrial Generator Set Accessories Line Circuit Breakers 15-2500 kw Standard Features Single Circuit Breaker Kit with Neutral Bus Bar 15-300 kw Model Shown The line circuit breaker interrupts the generator
More informationwww. ElectricalPartManuals. com ltciil Cutler-Hammer A WARNING
ltciil Cutler-Hammer TABLE OF CONTENTS I. L. 29C614C File 29-000 Instructions for The Digitrip RMS 310 3-Pole and 4-Pole Trip Unit Installation and Operation with K-Frame Series C Circuit Breakers Description
More informationCRITO Connection technology. Double and triple T and TCC section busbars
Centre feed unit 5 Centre feed unit Centre feed unit 5 Centre feed unit up to 4000 A combines the advantages of high short-circuit capacity, drill-free mounting, brace terminal technology and clearly structured
More informationWestinghouse Electric Corporation Distribution and Control Business Unit Electrical Components Division Pittsburgh, Pennsylvania, U.S.A.
December 1990 Supersedes 29-4, pages 3-4 dated September 1983 Mailed to: E, D, C/29-0A Distribution and Control Business Unit Electrical Components Division Pittsburgh, Pennsylvania, U.S.A. 2 Type OS Disconnect
More informationSelection and Application Guide Supplement. WL UL Pole Circuit Breakers. usa.siemens.com/wlbreaker
Selection and Application Guide Supplement WL UL1066 4-Pole Circuit Breakers usa.siemens.com/wlbreaker WL Power Circuit Breaker Table of Contents Ratings for UL 1066 (ANSI C37) Circuit Breakers Frame size
More informationWLI Medium Voltage Switchgear Renewal Parts
Page 1 Supersedes Renewal Parts Data, pages 1-2, dated June 1992, WLI Medium Voltage Switchgear Renewal Parts Page 2 Standard Manually Operated Fused WLI Switch ➇ ➁ ➀ ➂➃ WLI Switch Mechanism ➉ ➈ m Replacement
More informationSERIES POWER DISTRIBUTION BLOCKS
62000-69000 SERIES POWER DISTRIBUTION BLOCKS VERSATILE POWER DISTRIBUTION BLOCKS FOR CABLE TERMINATIONS Ferraz Shawmut Power Distribution Blocks afford a safe, convenient way of splicing cables, splitting
More informationStudded Power Feed Thru Terminal Blocks
ST722 Series The Studded Power Feed Thru were designed for applications where power feed thru is necessary using standard double hole lugs with.625 spacing. These terminal blocks are available in three
More informationSpring Reinforced. 30A & 60A Box. Spring. 30A Screw (R) Spring. 30A Screw. Spring Reinforced. 30A Pressure Plate
Class H, K & R USE LOCKS 250 & 600V CLASS H, K & R USE LOCKS RATINGS: Volts: 250VAC/DC, 600VAC/DC Amps: 30A, 60A, 00A, 0A, 400A, 600A SCCR: 0kA with class H fuses; 50kA with class K fuses; 0kA with class
More informationMP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION. MP Meter-Pak Meter Centers
Product Description PRODUCT DESCRIPTION MPH66125 with Horn Bypass Square D brand MP Meter-Pak meter centers from Schneider Electric offer a wide range of solutions for multi-metering applications: UL Listed
More informationYoungstown Power Limit Switches
Class March, 2012 September, 2008 FRONTLINE AC CRANE CONTROL CLASS 6420 Youngstown Power Limit Switches CONTENTS Description Class Page General Information and Selection...... 2 Application Information.....
More informationOPERATOR ADAPTER A21ABA
OPERATOR ADAPTER A21ABA Installation Instructions for Allen Bradley Bulletin 1494F Disconnect Switches And Bulletin 1494D Circuit Breaker Operating Mechanisms (For parts list, see page 2) For floor mounted
More informationMULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers
IEC Rated C60N/H/L Circuit Breakers Standard Features Fast Closing Allows increased withstand to the high inrush currents of some loads Trip-free mechanism: Contacts cannot be held in the on position when
More informationBBC. Renewal Parts. I-T-E Low-Voltage Power Circuit Breakers
BBC BROWN BOVERI RP 6..2.8-2C Renewal Parts I-T-E Low-Voltage Power Circuit Breakers Type K-000, 4000, 0008, and 40008 Stationary and Drawout Mounted 000 and 4000 Amperes 600 Volts RP 6..2.8-2 Page 2 Table
More informationStandard Materials Bodies and covers: copper-free aluminum.
-26 AEB Series: Bolted Combination and Non-Combination Full Voltage Motor Starters: Units Provide Disconnecting Means and Undervoltage, Circuit and Motor Running Protection. Application Combination and
More informationwww. ElectricalPartManuals. com POWER CIRCUIT BREAKERS TYPES AK-2/3/2A/3A-50, AKU-2/3/2A/3A-50, AKT-2/3/2A/3A-50 GENERAL fj ELECTRIC
ORDERNG NSTRUCTONS. Always specify complete nameplate data of the breaker. 2. Specify the quantity, catalog number (if listed), reference number (if listed), description, and this bulletin number. 3. Standard
More informationInstructions for the Digitrip RMS Pole and 4-Pole Trip Unit Installation and Operation with L-Frame and MOL-Frame Series C Circuit Breakers
Cutler-Hammer Table of Contents Instructions for the Digitrip RMS 310 3-Pole and 4-Pole Trip Unit Installation and Operation with L-Frame and MOL-Frame Series C Circuit Breakers PRESENT BEFORE PROCEEDING
More informationA200 NEMA Contactors and Starters A200
Starters Non-reversing and Reversing 11 Not to be used for construction purposes unless approved. Table 11. Open Reversing Starters Dimensions NEM of Poles Fig. Mounting Dimensions in Inches (mm) Screws
More informationwww. ElectricalPartManuals. com Instructions for Field Testing of Ground Fault Systems Utilizing Cutler-Hammer Magnum DS Circuit Breakers
Instructions for Field Testing of Ground Fault Systems Utilizing Cutler-Hammer Magnum DS Circuit Breakers The National Electrical Code makes the following statement regarding ground fault conformance testing:
More informationA. Submit manufacturer's literature and technical data before starting work.
SECTION 16425 SWITCHBOARD PART 1 GENERAL 1.01 SUMMARY A. Related Section: 1. 16450 - Grounding. 1.02 SUBMITTALS A. Submit manufacturer's literature and technical data before starting work. B. Submit Shop
More informationwww. ElectricalPartManuals. com
Instructions for Parcel-Line Type DH-P Circuit Breakers with Post Insulator Type Pole Units (Supplements I. B. 32-253-2) Westinghouse Electric Corporation Switchgear Division, East Pittsburgh, Pa. 15112
More information2018 Consultant s Handbook Division 26 Electrical 2413 Switchboards
1 General 1.1 Switchboards shall be U.L. listed and labeled. 1.2 Each switchboard shall have its own main disconnecting means unless it is located in the same room as its source of origin. In most cases
More informationCD5--- CA4--- CD6---- CB2---- CB4---- PARTS RECOMMENDED FOR NORMAL STOCK
RENEWAL PARTS CA2--- CD5--- CA4--- CD6---- CB2---- CB4---- ' PARTS RECOMMENDED FOR NORMAL STOCK NOTE: The current is identified by the number following the voltage letter in the IC designation. EXAMPLE:
More informationI.L. 29C121A WARNING 1. INTRODUCTION. Maximum Freq. Maximum Dielectric Voltage Current Withstand (V) (A) Voltage (V)
Installation Instructions for Auxiliary Switch for JDB, JD, HJD, JDC, JW, HJW, JWC Circuit Breakers, Molded Case Switches, and J-Frame Motor Circuit Protectors I.L. 9C11A! WARNING DO NOT ATTEMPT TO INSTALL
More informationCable-Operated Disconnect Switches. Accessories
Cable-Operated Disconnect Switches Accessories Description For Use With Auxiliary Contacts 1 N.O. Contact 1494C, 1494F, 1494V, and 1494G ( 1495-N8 1 N.O. Contact (low-level switching) A) Disconnect Switches
More informationTable Types LD, HLD and LDC Thermal-Magnetic Circuit Breakers with Interchangeable Trip Units
-1 1 Amperes July 07 Product Selection Table -191. s, H and C Thermal-Magnetic Circuit s with Interchangeable Trip Units Maximum Continuous Ampere at 40 C 2-Pole 0 0 3-Pole 0 0 4-Pole 0 0 Magnetic trip
More informationwww. ElectricalPartManuals. com It'll Cutler-Hammer WLI Medium Voltage Switchgear Renewal Parts Renewal Parts Data Page 1
t'll Cutler-Hammer Supersedes Renewal Parts Data, pages 1-2, dated June 1992 Renewal Parts Data Page 1 WL Medium Voltage Switchgear Renewal Parts Renewal Parts Data Page 2 WL Medium Voltage Switchgear
More informationNo-barrier design Self-extinguishing materials Front-connected, back-connected and flush-mounted styles Blades operate independently or can be ganged together Recognized by UL and cul STATES Type have
More informationRENEWAL PARTS I C302AA A-2 300V AB A-4800V A C A -SOOOV PARTS RECOMMENDED FOR NORMAL STOCK
NGrE: RENEWAL PARTS IC0A HIGH VOLTAGE CONTACTORS I C0AA 00A 00V AB00A800V A C 00A SOOOV PARTS RECOMMENDED FOR NORMAL STOCK The current is identified by the number following the voltage letter in the IC
More informationFOR PRICES ON DSII and DSLII BREAKERS, REFER TO PRICE LIST PL.22B.01.P.E
Supersedes PL.44B.04.P.E Dated September 1998 600 Volts AC Maximum 200 ka, RMS Sym. Short Circuit Maximum 800-5000 Amps Continuous Effective: October 1999 Page 1 Index Page Table Description/Application...
More informationCrane Control Class 9055
Catalog 17 CONTENTS Description.....................................................Page pplication Data................................................... General Information and Pricing.......................................
More informationNEMA Contactors & Starters (Freedom)
Page 1 February, 1 Supersedes TIP AN1, AN, CN1, CN Pages 1-0, Dated 1/1/4 ECN01, ECN0, ECN0, ECN0, ECN0 AN1, AN, CN1 & CN Sizes 00-, 00V Max. Non-Reversing & Reversing NEMA Type Enclosures 1, R, 4X & 1
More informationCIRCUIT BREAKERS. Explosionproof Circuit Breaker Enclosures EXPLOSIONPROOF MOTOR CONTROL EXPLOSIONPRROOF MOTOR CONTROL BREAKERS ENCLOSURES
CIRCUIT BREAKERS Explosionproof Circuit Breaker Enclosures BREAKERS Circuit breakers are thermal magnetic type and are available in frame sizes ranging from 15 to 800 amperes Also available as non-automatic
More information