Installation Guide for AC-5000 V1.0 Fingerprint Identification Terminal. Apr., R&D Center Union Community Co., Ltd.

Size: px
Start display at page:

Download "Installation Guide for AC-5000 V1.0 Fingerprint Identification Terminal. Apr., R&D Center Union Community Co., Ltd."

Transcription

1 Installation Guide for AC-5000 V1.0 Fingerprint Identification Terminal Apr., R&D Center Union Community Co., Ltd.

2 1. The Description of External Cables GND (BK) V (RE) - 1 P - 3 P - 2 P - 1 Power Adapter Cable GND(BR)-5 IN1 (RE) - 4 IN0 (OR) - 3 OUT1 (YE) - 2 OUT0 (BK) - 1 Wiegand Cable (5P) GND (BK) - 3 RXD (BR) - 2 TXD (RE) - 1 RS232 Cable (3P) 2

3 2-1. Connecting Ethernet (LAN) Cable J451-RJ45 ** UTP Connector UTP 10Base-T Switch Hub 3

4 Connecting Ethernet (LAN) Cable For PoE J451-RJ45 ** UTP Connector UTP 10Base-T Switch Hub With PoE When using PoE, can t connect an electric lock together. When connects an electric lock, you must use the 12v power adapter. But you can only use PoE at 7.3, 8.1, 8.2 & 11 Type (no powered contact) 4

5 3. Setting the Resistor of RS485 Ended Termination SW405 SW405 OFF ON * Default Setting is off. * ON: 120 Ohm Resistior is connected between 485A and 485B 5

6 4. Connecting Dead-Bolt Type Door Lock (Fail Safe) 4.1. Connect with One System/ One Lock - C + (-)Black (+)Red ON WnP Door Monitor Door Open S/W 6

7 4. Connecting Dead-Bolt Type Door Lock (Fail Safe) 4.2. Connect with Two Systems/ One Lock System 1 System 2 (-)Black - C + (+)Red ON WnP Door Monitor System 1 System 2 7

8 5. Connecting Strike Type Door Lock (Fail Safe) 5.1. Connect with One system/ One Lock (-)Black (+)Red Door Monitor Door Open S/W 8

9 5. Connecting Strike Type Door Lock (Fail Safe) 5.2. Connect with Two systems/ One Lock System 1 System 2 (-)Black (+)Red Door Monitor System 1 System 2 9

10 6. Connecting Strike Type Door Lock (Fail Secure) 6.1. Connect with One system/ One Lock (-)Black (+)Red Door Monitor Door Open S/W 10

11 6. Connecting Strike Type Door Lock (Fail Secure) 6.2. Connect with Two systems/ One Lock System 1 System 2 (-)Black (+)Red Door Monitor System 1 System 2 11

12 7. Connecting EM Type Door Lock (Fail Safe) 7.1. Connect with One system/ One Lock (+)Red (-)Black Door Monitor Door Open S/W 12

13 7. Connecting EM Type Door Lock(Fail Safe) 7.2. Connect with Two System/ One Lock System 1 System 2 (-)Black (+)Red Door Monitor System 1 System 2 13

14 7. Connecting EM Type Door Lock (Fail Safe) 7.3. Connect with One system/ Two Locks ** Use external DC Power adapter Lock 1 - (Black) 12V 3A Adapter (-) (+) + (Red) Door Monitor J401(5P) Door Open S/W GND(5) 485B-(4) 485A+(3) GND(2) +12V(1) Lock 2 14

15 8. Connecting Auto-Door (Contact Control) 8.1. Connect with One system/ One Door Auto Door Operating Part Auto-Door Sensor Auto Door Motor Auto-Door Monitor Sensor Input Line 9P CONN Door Open S/W 15

16 8. Connecting Auto-Door (Contact Control) 8.2. Connect with Two systems/ One Door System 1 System 2 Auto Door Operating Part Auto Door Motor Auto-Door Sensor Auto-Door Monitor Sensor Input Line 9P CONN System 1 System 2 16

17 9. Connecting Motor Lock Blue Brown Orange White Yellow Black DM1 DM2 Motor 1 Motor 2 Door Monitor Unlock Signal Exit B Ground GND GND (5) 485B- (4) 485A+ (3) GND (2) +12V (1) Door Open S/W J401(5P) 17

18 10. Connecting 2 Emergency Lamps Emergency Lamp 1 Emergency Lamp 2 12 V (+) Ground (-) ( 12 V (+) Ground (-) ( J401(5P) +12V(1) GND(2) 485A+(3) 485B-(4) GND(5) 18

19 11. Connecting Electronic Lock With PoE Normal Open Type J451-RJ45 12V Adapter +12V GND UTP 10Base-T Switch Hub With PoE 19

20 11. Connecting Electronic Lock With PoE Normal Close Type J451-RJ45 12V Adapter +12V GND UTP 10Base-T Switch Hub With PoE 20

Installation Guide for AC-7000 V1.0 Face Recognition Terminal

Installation Guide for AC-7000 V1.0 Face Recognition Terminal Installation Guide for AC-7000 V1.0 Face Recognition Terminal Doc Ver1.2 Dec.,24.2014 R&D Center Union Community Co., Ltd. 1. The maximum cable length & thickness for installation 1) Using 12V 3.5A Power

More information

Installation Guide for AC-6000 V1.0 Fingerprint Identification Terminal. Doc. Ver. : V1.00 Apr., R&D Center Union Community Co., Ltd.

Installation Guide for AC-6000 V1.0 Fingerprint Identification Terminal. Doc. Ver. : V1.00 Apr., R&D Center Union Community Co., Ltd. Installation uide for AC-000 V.0 Fingerprint Identification Terminal Doc. Ver. : V.00 Apr.,0.00 R&D Center Union Community Co., Ltd. . Power Connector connection ND (BK) - +V (RE) - P - P - P - Power Adapter

More information

Fingerprint/Card Terminal AC-6000 V2.0

Fingerprint/Card Terminal AC-6000 V2.0 Fingerprint/Card Terminal AC-000 V.0 Installation & Wiring uide Doc. Ver. : V.0 Aug.,.0 R&D Center Union Community Co., Ltd. . Power Connector connection ND (BK) - +V (RE) - P - P - P - Power Adapter Interface

More information

RS485 Card. User Manual

RS485 Card. User Manual RS485 Card User Manual Version 1.2.2 2010.02 Page 1 Table of Contents: 1. Safety Instructions for installation and application...3 Read this User Manual before you start...5 2. Features...6 3. Appearance...7

More information

Zodiac Max INSTALLATION MANUAL

Zodiac Max INSTALLATION MANUAL Zodiac Max INSTALLATION MANUAL October 2015 Table of Contents Introduction... 4 Specifications... 5 Overview... 6 Reader Address Settings... 7 Wiring to a Wiegand Controller... 8 CLAUSB... 9 CLAUSB2...

More information

INSTALLATION GUIDE. InBio Pro Series Access Control Panels. Date: Dec., 2015 Version: 1.1

INSTALLATION GUIDE. InBio Pro Series Access Control Panels. Date: Dec., 2015 Version: 1.1 INSTALLATION GUIDE InBio Pro Series Access Control Panels Date: Dec., 2015 Version: 1.1 2 3 What s in the Box CONTENT 2 Screws & Anchors 2 Screwdriver 4 Diode Contents What s in the Box...2 Optional accessories...4

More information

Battery Voltage, Overload Protected Hot only in Start & Run 15 GN (green)

Battery Voltage, Overload Protected Hot only in Start & Run 15 GN (green) Wiring Diagrams Design of Wiring System Determine and Define of Wires Circuit Numbers and Wire Identification will be done according the World-wide Engineering Drafting Standard WH-110-01. The circuit

More information

Assembly Manual for New Control Board 22 June 2018

Assembly Manual for New Control Board 22 June 2018 Assembly Manual for New Control Board 22 June 2018 Parts list Arduino 1 Arduino Pre-programmed 1 Faceplate Assorted Header Pins Full Board Rev A 9 104 capacitors 1 Rotary encode with switch 1 5-volt regulator

More information

QUICK START GUIDE FOR ACCESS CONTROL BOARDS. DX Series Four Door TCP/IP Web Server Controller. Model: ACP-DXEL4

QUICK START GUIDE FOR ACCESS CONTROL BOARDS. DX Series Four Door TCP/IP Web Server Controller. Model: ACP-DXEL4 QUICK START GUIDE FOR ACCESS CONTROL BOARDS DX Series Four Door TCP/IP Web Server Controller Model: ACP-DXEL Table of Contents 0- Introduction 0 - Overview 0. - Package Contents 0. - Installation Requirements

More information

Eternity-TK-Controller (EDC700 Series)

Eternity-TK-Controller (EDC700 Series) Eternity-TK-Controller (EDC700 Series) Product Datasheet www.ibuttonlock.com SPECIFICATIONS Power Supply: 12V, 3A Main Relay: 12V, 5A Operating Temp: -18 C to +70 C (0 F to +158 F) Power Consumption: 15

More information

Safety Precautions Product Contents Product PIN Diagram LED indicators Product Dimensions Installation of Panel with Casing Wire Legend Power Wiring

Safety Precautions Product Contents Product PIN Diagram LED indicators Product Dimensions Installation of Panel with Casing Wire Legend Power Wiring www.zkteco.com Safety Precautions Product Contents Product PIN Diagram LED indicators Product Dimensions Installation of Panel with Casing Wire Legend Power Wiring Diagram FR1200 Connection Weigand Connection

More information

LOAD CELL-JUNCTION BOX- INDICATOR CONNECTION

LOAD CELL-JUNCTION BOX- INDICATOR CONNECTION LOAD CELL-JUNCTION BOX- INDICATOR CONNECTION The intent of this technical note is help the user when making connections of a 4 or 6 wires UTILCELL load cell to a junction box and to a indicator types DAT,

More information

pink 5 wire dash fuse box, black 51 pin plug (C), pin 26 red (key lock); gray (detection) (Tech Doc 1300)

pink 5 wire dash fuse box, black 51 pin plug (C), pin 26 red (key lock); gray (detection) (Tech Doc 1300) Page 1 of 5 Wiring Information 12 Volts gray (30A) + ignition switch, black 6 pin plug, pin 1 Second 12 Volts green (40A) + ignition switch, black 6 pin plug, pin 5 Starter red + ignition switch, black

More information

Central Locking Diagrams

Central Locking Diagrams Central Locking Diagrams DIAGRAM N. 2 CLOSURE TIME 0,5 SECONDS. +30 COMMON (Positive or Negative) OPEN CLOSE DIAGRAM N. 3 CLOSURE TIME 6 SECONDS. +30 COMPRESSOR ORIGINAL ACTUATOR DIAGRAM N. 4 CLOSURE TIME

More information

PKS-FD Servo System

PKS-FD Servo System PKS-FD123-01 Servo System FEATURES 24-70VDC of 0.32 Nm Power Ratings up to 100 Watts 2,500 PPR Incremental Encoder Maximum Speed of 6500 RPM IP65 for Body, IP54 Shaft Seal Brake Option Available Position,

More information

SCP Hardware Quick Reference

SCP Hardware Quick Reference SP Hardware Quick Reference RS Technologies, LL - 00 Fisher Street, Suite G - Munster, IN 6 - (877) 68- - Fax (9) 86-90 www.rstech.com Revised: /08 Table Of ontents MODEL PAGE MODEL PAGE MINI-SP MINI-SPE

More information

KNC-PKS-FD S-AAK-DKH

KNC-PKS-FD S-AAK-DKH KNC-PKS-FD123-02 - Servo System FEATURES 24-70VDC of 90 oz-in Power Ratings up to 200 Watts 2,500 PPR Incremental Encoder Maximum Speed of 6000 RPM IP65 for Body, IP54 Shaft Seal Brake Option Available

More information

Transporter Current Flow Diagram No. 671 / 1 Edition

Transporter Current Flow Diagram No. 671 / 1 Edition Side 1 av 9 Transporter Current Flow Diagram No. 671 / 1 Edition 07.2008 Exterior, electric Window, electric Without anti-theft alarm system Without central locking lock unit from November 2007 Notes:

More information

RC Engine-EFI. Installation Manual

RC Engine-EFI. Installation Manual RC Engine-EFI RC Engine Electronic Fuel Injection -- Conversion Kit For 120cc to 300cc engines Installation Manual ECOTRONS V1.2.3 http://www.ecotrons.com/ COPY RIGHTS ECOTRONS LLC ALL RIGHTS RESERVED

More information

SUPER CAPACITOR CHARGE CONTROLLER KIT

SUPER CAPACITOR CHARGE CONTROLLER KIT TEACHING RESOURCES ABOUT THE CIRCUIT COMPONENT FACTSHEETS HOW TO SOLDER GUIDE POWER YOUR PROJECT WITH THIS SUPER CAPACITOR CHARGE CONTROLLER KIT Version 2.0 Teaching Resources Index of Sheets TEACHING

More information

Console Cable Troubleshooting Bike and Elliptical

Console Cable Troubleshooting Bike and Elliptical Prepared by: Emilie McWilliams Date Prepared: 4/9/2015 Models Affected: AFG, Horizon, Livestrong, and Vision bikes and ellipticals 2001 - present DESCRIPTION Use this guide to troubleshoot an analog console

More information

Silvertel. Ag Features. Multi-Stage Charging. Battery Reversal Protection. Reduced Power Consumption. Wide DC or AC Input Voltage Range

Silvertel. Ag Features. Multi-Stage Charging. Battery Reversal Protection. Reduced Power Consumption. Wide DC or AC Input Voltage Range Silvertel V1.3 October 2009 Datasheet Intelligent Pb 1 Features Multi-Stage Charging Battery Reversal Protection Reduced Power Consumption Wide DC or AC Input Voltage Range High Efficiency DC-DC Converter

More information

P0102-MASS AIR FLOW SENSOR "A" CIRCUIT LOW

P0102-MASS AIR FLOW SENSOR A CIRCUIT LOW 7 - D - RAM 5 PICKUP - 6.7L CUMMINS TURBO DIESEL P- SENSOR "A" CIRCUIT LOW BATT A FUSE 7 5A TOTALLY INTEGRATED C A8 8 RD/OR S A8 8 RD/OR A8 8 RD/OR FUSED B(+) RELAY RETURN 5 FUSED B(+) RELAY FEED RELAY-

More information

:34 1/15 Hub-4 / grid parallel - manual

:34 1/15 Hub-4 / grid parallel - manual 2016-02-24 11:34 1/15 Hub-4 / grid parallel - manual Hub-4 / grid parallel - manual Note: make sure to always update all components to the latest software when making a new installation. Introduction Hub-4

More information

AXIAL LEADED COATED INDUCTORS

AXIAL LEADED COATED INDUCTORS EC TYPE COLOR CODE GUIDE In EC TYPE series color band are marked for identification. These bands indicate inductance value and tolerance. For values below 0.1uH, Gold indicates the decimal point and the

More information

Hub-4 / grid parallel - manual

Hub-4 / grid parallel - manual Hub-4 / grid parallel - manual Note: make sure to always update all components to the latest software when making a new installation. Introduction Hub-4 is a Grid-parallel Energy Storage system, using

More information

Connections to Microtec Standard Globe Tower Light (with internal buzzer) Microtec Light Control Module MkII

Connections to Microtec Standard Globe Tower Light (with internal buzzer) Microtec Light Control Module MkII Connections to Microtec Standard Globe Tower Light (with internal buzzer) Connecting a Standard Globe Tower Light to a Microtec Light Control Module Mk II: Route wires from the light fitting to the Light

More information

Guide to Paux System for Motor Caravans Model AS PAUX v. 1.0

Guide to Paux System for Motor Caravans Model AS PAUX v. 1.0 Guide to Paux System for Motor Caravans 006-007 Model AS PAUX v..0 PauX System Instructions ArSilicii Rel..0 Cautions The material contained herein is the property of ArSilicii S.r.l. and may not be reproduced

More information

CONTENTS 1. Introduction.1 2. Features Panel 3 4. Fail indicators.4 5. Operation 8 6. Battery replacement.12 7.

CONTENTS 1. Introduction.1 2. Features Panel 3 4. Fail indicators.4 5. Operation 8 6. Battery replacement.12 7. CONTENTS 1. Introduction.1 2. Features..1 3. Panel 3 4. Fail indicators.4 5. Operation 8 6. Battery replacement.12 7. Specifications 14 1. Introduction The network cable tester is a small hand-held cable

More information

SRS AIRBAG CONTROL SYSTEM

SRS AIRBAG CONTROL SYSTEM RESTRAINTS SECTION SRC A SRS AIRBAG CONTROL SYSTEM B C D CONTENTS E PRECAUTION... 4 PRECAUTIONS... 4 Precaution for Supplemental Restraint System (SRS) "AIR BAG" and "SEAT BELT PRE-TEN- SIONER"...4 Precaution

More information

Wind display type WSDI-2

Wind display type WSDI-2 USER s MANUAL/INSTALLATION NOTE Wind display type WSDI-2 Input and wiring Mounting Document no.: 4189350032C Table of contents 1. INTRODUCTION... 3 UNPACKING... 3 2. INPUT AND WIRING INSTRUCTION... 4 3.

More information

Installation Instructions Used in Conjunction with the MultiWave V3.4 Software

Installation Instructions Used in Conjunction with the MultiWave V3.4 Software WARNING - Risk of Fire or Electric Shock MODEL P5043ME MultiWave Expansion Module Installation Instructions Used in Conjunction with the MultiWave V3.4 Software Disconnect all power before installing or

More information

ZONE PRESENCE SENSOR FEATURES SPECIFICATIONS TABLE OF CONTENTS. VAV system using a Zone Presence Sensor.

ZONE PRESENCE SENSOR FEATURES SPECIFICATIONS TABLE OF CONTENTS. VAV system using a Zone Presence Sensor. ZONE PRESENCE SENSOR Phoenix Controls Zone Presence Sensor (ZPS ) detects the presence of personnel in front of a fume hood. When an operator is present, the ZPS signals the fume hood system into the standard,

More information

2006+ Toyota Yaris Remote Start Wiring Guide

2006+ Toyota Yaris Remote Start Wiring Guide 2006+ Toyota Yaris Remote Start Wiring Guide Note: This guide assumes that the user has a good working knowledge of automotive electrical systems. The user assumes all liability for any damage resulting

More information

Telephonic Car Alarm and Remote Starter Wiring Schematics

Telephonic Car Alarm and Remote Starter Wiring Schematics Telephonic Car Alarm and Remote Starter Wiring Schematics CLV INPUT-OUTPUT WIRING W - W ASPECT GENERAL 2 NOTE AFTER THE WIRING IS COMPLETE ALL STICKER #'s MUST BE REMOVED 0 AMPS ANTENA 2 3 4 9 0 2 3 4

More information

Cabinet Control Unit (CCU) User Manual

Cabinet Control Unit (CCU) User Manual www.akcp.com Cabinet Control Unit (CCU) User Manual Help Version updated till firmware 404n Copyright 2012, AKCess Pro Limited 1) Introduction What is the CCU? How to use this manual 2) Package Contents

More information

V-DW2425A / V-DW2440 and V-DW11025A / V-DW11040A

V-DW2425A / V-DW2440 and V-DW11025A / V-DW11040A Installation Manual V1.05 V-DW2425A / V-DW2440 and V-DW11025A / V-DW11040A The Sapling Company, Inc. 1633 Republic Road Huntingdon Valley, PA 19006 215.322.6063 P. 215.322.8498 F. www.sapling-inc.com Valcom

More information

Security alarms, warning systems.

Security alarms, warning systems. SIREN DRIVER BOARD. Free running siren activated by the application of a V DC power source. This module is capable of driving a maximum of 2 x 8 ohm 10W speakers and produces approximately 110 db at one

More information

Transporter Current Flow Diagram No. 63 / 1 Edition

Transporter Current Flow Diagram No. 63 / 1 Edition Side 1 av 18 Transporter Current Flow Diagram No. 63 / 1 Edition 03.2009 Day driving light from March 2003 Notes: For information concerning Position of relays and fuses Multi-pin s Control units and relays

More information

RJ45 10/100/1000 Base-TX Tab down 1x4 Jack with Magnetic Module. Storage temperature range: -40ºC to +85ºC. LEDs. EMI Fingers (see Mechanical)

RJ45 10/100/1000 Base-TX Tab down 1x4 Jack with Magnetic Module. Storage temperature range: -40ºC to +85ºC. LEDs. EMI Fingers (see Mechanical) RJ45 0/00/000 Base-TX Tab down x4 Jack with Magnetic Module ARJ4A 59. x 3.60 x.50 mm / 5.40 x 3.00 x 0.54mm FEATURES: Tab down Available with or without LED Suitable CAT 5 & 6 cable and UTP Comply IEEE

More information

1260 Infinity II Degasser User Manual. 5 Maintenance

1260 Infinity II Degasser User Manual. 5 Maintenance 1260 Infinity II Degasser User Manual 5 Maintenance Warnings and Cautions 40 Simple Repairs - Maintenance 42 Clean the Instrument 43 Assemble the Main Cover 44 Check and Change the Power Fuses 45 This

More information

AGELKOM CAP04 Plasma and Oxy Fuel Torch height control for sheet metal cutting machines Height Sensor & Controller

AGELKOM CAP04 Plasma and Oxy Fuel Torch height control for sheet metal cutting machines Height Sensor & Controller 6 PIN INTERFACE BNC HEIGHT CONTROL KNOB CAP 04 CAPACITIVE HEIGHT CONTROLLER DOWN IN POSITION UP TOUCH CABLE FAULT AGELKOM CAP04 Plasma and Oxy Fuel Torch height control for sheet metal cutting machines

More information

UAV engine EFI installation manual

UAV engine EFI installation manual UAV engine EFI installation manual -DLE120 engine Installation Manual V1.7 COPY RIGHTS ECOTRONS LLC ALL RIGHTS RESERVED Http://www.ecotrons.com 1 Note: If you are not sure about any specific details, please

More information

Bendix BlindSpotter Collision Warning System. Troubleshooting Guide

Bendix BlindSpotter Collision Warning System. Troubleshooting Guide Bendix BlindSpotter Collision Warning System Troubleshooting Guide Bendix BlindSpotter Collision Warning System BW860 (Formerly VOTS003) September 0 General Information General Warnings Before starting

More information

INSTALLATION MANUAL FOR

INSTALLATION MANUAL FOR MOUNTING LOCATION Reader RD- FOR RF CONTROLLER VIZIT-KTM60 R, EXIT 00M BUTTON This manual is intended as an addition to operating instructions on your access control system (ACS) units to guide through

More information

Lab # 4 Parallel Circuits

Lab # 4 Parallel Circuits Lab # 4 Parallel Circuits Name(s) Obtain an Electro-Trainer and wire it exactly as shown (Be sure to use the 100 ohm resistor) 1) Record the volt drop and current flow for the Switch, the Resistor and

More information

blue 5 wire dash fuse box, white 20 pin plug (E), pin 8 red (key lock); gray (detection) (Tech Doc 1300)

blue 5 wire dash fuse box, white 20 pin plug (E), pin 8 red (key lock); gray (detection) (Tech Doc 1300) Page 1 of 5 Wiring Information 12 Volts red (40A) + ignition switch, white 6 pin plug, pin 1 Second 12 Volts pink (30A) + ignition switch, white 6 pin plug, pin 5 Starter green + ignition switch, white

More information

Prins autogassystemen b.v. Veldhoven

Prins autogassystemen b.v. Veldhoven Prins autogassystemen b.v. Veldhoven MOUNTING INSTRUCTION ENGINE CONVERSION SET MAKE OF AUTOMOBILE: TYPE: ASTRA PISTON DISPLACEMENT: 2000 cc MT NUMBER OF VALVES: 16V ENGINE NUMBER: X20XEV INJECTION SYSTEM:

More information

CCIE Routing & Switching Hardware Specification

CCIE Routing & Switching Hardware Specification CCIE Routing & ing Lab Topology CCIE Routing & ing Hardware Specification Internetwork Expert s CCIE Routing & ing Lab Workbook Volume II uses the same hardware specification that is used in the actual

More information

RDAC XG Engine monitoring module for MGL Avionics CAN bus compatible EFIS systems.

RDAC XG Engine monitoring module for MGL Avionics CAN bus compatible EFIS systems. RDAC XG Engine monitoring module for MGL Avionics CAN bus compatible EFIS systems. This Engine monitor is fully compatible with the larger RDAC XF device. Compared to the RDAC XF the following inputs are

More information

Data sheet Connection line M12 plug straight - RJ45 plug straight 8-pole, X-coded 5.0 m

Data sheet Connection line M12 plug straight - RJ45 plug straight 8-pole, X-coded 5.0 m Page 1/5 Illustrations Dimensional drawing See enlarged drawings at the end of document Product specification shielded M12-plug to RJ45-plug connection line Cat.6, 8-pole M12-connector, X-coded, straight

More information

GTFM V. Operation / Installation Manual. Gas Turbine Flow Monitor. Computer Weld Technology, Inc. Manual Part Number: A8M5026 Revised: 09/11/2013

GTFM V. Operation / Installation Manual. Gas Turbine Flow Monitor. Computer Weld Technology, Inc. Manual Part Number: A8M5026 Revised: 09/11/2013 Computer Weld Technology, Inc. 10702 Old Bammel N Houston Rd. Houston, TX 77086 Phone: (713) 462-2118 Fax: (713) 462-2503 Email: cwt@cweldtech.com GTFM V Gas Turbine Flow Monitor Operation / Installation

More information

Intelligent DC UPS Module

Intelligent DC UPS Module Intelligent DC UPS Module 12V/9~36V DC Input, 12V DC Output Uninterruptible Power Supply Module with Diagnostics VESA or VESA mounting 9-36V input through terminal or power jack, or 12V through power jack

More information

Troubleshoot Safety Circuits

Troubleshoot Safety Circuits Troubleshoot Safety Circuits Troubleshoot Safety Circuits GMEC96 and GMVC96 Furnaces Safety circuits serve to control any potential safety hazards, and are in place to ensure proper furnace operation.

More information

PLUS PLUS & PRO. Installation manual

PLUS PLUS & PRO. Installation manual PLUS PLUS & PRO Installation manual Safety warnings Manual for Maxem Plus and Pro Energy Manager. Publication Date: May 15, 2017 Questions or improvements If you see any errors or defects, if you have

More information

Silver T E L E C O M. 1. Features. 2. Description. IEEE802.3af compliant. Small SIL package size - 56mm (L) x 14mm (H) Low output ripple and noise

Silver T E L E C O M. 1. Features. 2. Description. IEEE802.3af compliant. Small SIL package size - 56mm (L) x 14mm (H) Low output ripple and noise Silver T E L E C O M V2.0 Aug 2008 Pb. Features IEEE802.3af compliant Small SIL package size - 56mm (L) x 4mm (H) Low output ripple and noise Input voltage range 36V to 57V Only one low cost external decoupling

More information

LSM60 Series. Brushless Servo Motors. Product Description

LSM60 Series. Brushless Servo Motors. Product Description LSM60 Series Brushless Servo Motors Product Description The LSM60 series servo motors offer high performance with wide output range from 00W to.5 kw*. This series motors are designed to operate over a

More information

Silvertel. Ag5500. PoE Ultra Module. 1. Features. 2. Description. Maximum 60 Watt Output Power. Small size (½ Brick) High efficiency DC/DC converter

Silvertel. Ag5500. PoE Ultra Module. 1. Features. 2. Description. Maximum 60 Watt Output Power. Small size (½ Brick) High efficiency DC/DC converter Silvertel V.4 Aug 04 Datasheet. Features Maximum 0 Watt Output Power Small size (½ Brick) High efficiency DC/DC converter Wide adjustable output voltage range 500V isolation (input to output) Input voltage

More information

blue 5 wire dash fuse box, white 20 pin plug (E), pin 8 red (key lock); gray (detection) (Tech Doc 1300)

blue 5 wire dash fuse box, white 20 pin plug (E), pin 8 red (key lock); gray (detection) (Tech Doc 1300) Page 1 of 5 Wiring Information 12 Volts red (40A) + ignition switch, white 6 pin plug, pin 1 Second 12 Volts pink (30A) + ignition switch, white 6 pin plug, pin 5 Starter green + ignition switch, white

More information

O500LE O500RF. How to Read Wiring Diagrams: IV - 15 / 3 X / 7 W 02 01

O500LE O500RF. How to Read Wiring Diagrams: IV - 15 / 3 X / 7 W 02 01 Introduction: Wiring diagrams are now structured in a new format, which allows for better identification of components and connections/plugs. Control unit Connectors: Each of these connectors identify

More information

Industrial Renewable Energy. 4-Port 10/100/1000T 802.3at PoE+ Managed Ethernet Switch BSP-360. Quick Installation Guide

Industrial Renewable Energy. 4-Port 10/100/1000T 802.3at PoE+ Managed Ethernet Switch BSP-360. Quick Installation Guide Industrial Renewable Energy 4-Port 10/100/1000T 802.3at PoE+ Managed Ethernet Switch BSP-360 Quick Installation Guide Safety Precautions Please read the following before using: 1. All electrical work must

More information

Silvertel. Ag Features. Multi-Stage Charging. Battery Reversal Protection. Reduced Power Consumption. Wide DC or AC Input Voltage Range

Silvertel. Ag Features. Multi-Stage Charging. Battery Reversal Protection. Reduced Power Consumption. Wide DC or AC Input Voltage Range Silvertel V1.1 October 2012 Pb 1 Features Multi-Stage Charging Battery Reversal Protection Reduced Power Consumption Wide DC or AC Input Voltage Range High Efficiency DC-DC Converter Programmable Charge

More information

User s manual. RS232. PressurePro tire-pressure monitoring system connection

User s manual. RS232. PressurePro tire-pressure monitoring system connection Necessary tools, devices, materials To connect GALILEOSKY terminal (hereinafter terminal) one should have: 1. Electrical tools. Picture 1 2. Windows-based computer with the installed program of configuration

More information

SP PRO KACO Managed AC Coupling

SP PRO KACO Managed AC Coupling SP PRO KACO Managed AC Coupling Introduction The SP PRO KACO Managed AC Coupling provides a method of linking the KACO Powador xx00 and Powador xx02 series grid tie inverters to the SP PRO via the AC Load

More information

1 EASY COMMISSIONING GUIDE FRONIUS PV-SYSTEM CONTROLLER

1 EASY COMMISSIONING GUIDE FRONIUS PV-SYSTEM CONTROLLER 1 EASY COMMISSIONING GUIDE FRONIUS PV-SYSTEM CONTROLLER Reading this document does not substitute for user s reference to CIRCUTOR CDP-DUO user-guide. 1.1 Scope Using Fronius grid-tie inverters in remote

More information

BMS RS-485 Card/Box Quick Guide Applicable for hybrid inverter 3KW-10KW

BMS RS-485 Card/Box Quick Guide Applicable for hybrid inverter 3KW-10KW Thank you for purchasing RS485 card/box. This manual contains instructions and warnings that should be followed during the installation, operating and storage of the card. Please keep this manual for further

More information

GSC400 Series. Automatic Gen-Set Controller Manual. Revision 2.6

GSC400 Series. Automatic Gen-Set Controller Manual. Revision 2.6 GSC400 Series Automatic Gen-Set Controller Manual Revision 2.6 GSC400 Automatic Gen-Set Controller Installation and User Manual MAN-0076 Rev2.6, GSC400 User Manual.doc, May 2010 2 of 105 Thank You For

More information

GEMÜ 539 esydrive Motorized globe valve

GEMÜ 539 esydrive Motorized globe valve esydrive Motorized globe valve Features Linear or modified equal-percentage control characteristics High flow rates Force and speed are variably adjustable Extensive diagnostic facilities Operable via

More information

CROSS TRAINER 95X-0XXX-01. Customer Support Services PARTS MANUAL rev. 12/15/05. Page 1 of 14

CROSS TRAINER 95X-0XXX-01. Customer Support Services PARTS MANUAL rev. 12/15/05. Page 1 of 14 CROSS TRAINER Customer Support Services PARTS MANUAL rev. 12/15/05 Page 1 of 14 REFERENCES OPERATION MANUAL SERVICE MANUAL HARDWARE BAG PLUG IN OPTION120/60 PLUG IN OPTION 240/50 UK PLUG IN OPTION 240v

More information

Electric Actuator Instructions

Electric Actuator Instructions BAC IOM Electric Actuator Instructions E024, E025, E026, E029 & E030 TABLE OF CONTENTS Electric Actuator Specifications...2 Overview...3 Actuator Wiring Diagrams...4 VMS-35 Specifications and Wiring Diagram...5

More information

GS2 Series - Introduction

GS2 Series - Introduction GS2 Series - Introduction GS2 Series Drives Rating Hp.25.5 1 2 3 5 7.5 10 kw 0.2 0.4 0.75 1.5 2.2 3.7 5.5 7.5 Single-Phase 115 Volt Class Single/Three-Phase 230 Volt Class Three-Phase 230 Volt Class Three-Phase

More information

Advanced Battery Charger. 3 - stage charging capability (IUOU) 4.1 A / 100VAC 1.8A / 240VAC

Advanced Battery Charger. 3 - stage charging capability (IUOU) 4.1 A / 100VAC 1.8A / 240VAC Cxx Features: Universal AC input with active PFC Compatible with Lead Acid, Li-ion, Gel and AGM batteries Support optional remote controller (CR-) Voltage / temperature compensation with battery temp.

More information

Installation Instructions for: Channel Thermocouple Amplifier

Installation Instructions for: Channel Thermocouple Amplifier Installation Instructions for: 30-2204 4 Channel Thermocouple Amplifier WARNING: This installation is not fo r the electrically or mechanically challenged! Use this sensor with EXTREME caution! If you

More information

DP K9 Door Popper Installation Manual. Patented

DP K9 Door Popper Installation Manual. Patented DP-3000 Patented K9 Door Popper Installation Manual Radiotronics Inc. 1315 SW Commerce Way Stuart FL 34997 Phone: 772-600-7574 Fax: 772-600-7012 www.acek9.com Introduction The K9 Door Popper features a

More information

Zonestar Installation Manual

Zonestar Installation Manual Zonestar Installation Manual National Sales Ph: 1300 306 125 sales@ias.net.au Product Support Freecall: 1800 354 434 support@ias.net.au Designed and Manufactured in Australia by: Innovative Air Systems

More information

Video Intercom Firmware V1.5.0 UK Release Notes ( )

Video Intercom Firmware V1.5.0 UK Release Notes ( ) Video Intercom Firmware V1.5.0 UK Release Notes (2018-11-28) Firmware Version: Indoor Station/Master Station H5 Platform Door Station H0 Platform Door Station H2 Platform Door Station V1.5.0bulid181121

More information

2015 EDITION SUBMERSIBLE MOTORS AIM MANUAL. APPLICATION INSTALLATION MAINTENANCE 60 Hz, Single-Phase and Three-Phase Motors. franklinwater.

2015 EDITION SUBMERSIBLE MOTORS AIM MANUAL. APPLICATION INSTALLATION MAINTENANCE 60 Hz, Single-Phase and Three-Phase Motors. franklinwater. 0 EDITION AIM MANUAL SUBMERSIBLE MORS APPLICATION INSTALLATION 60 Hz, Single-Phase and Three-Phase Motors franklinwater.com All Motors System Troubleshooting Motor Does Not Start A. No power or incorrect

More information

Cisco Power Calculator -Power Results

Cisco Power Calculator -Power Results Cisco Power Calculator -Power Results Disclaimer: The Cisco Power Calculator is intended to be an educational resource and a starting point in planning your power requirement; it is not a final recommendation

More information

Senior Swing Control Box. Table of Contents

Senior Swing Control Box. Table of Contents *740100* 740100 2800 Overhead Consealed Series 9500 Surface Applied Series Senior Swing Control Box Installation Instructions important These instructions are presented in step-by-step sequence. It is

More information

KNC-SRV-FD123-CA-000 Series Servo Driver

KNC-SRV-FD123-CA-000 Series Servo Driver FEATURES DESCRIPTION Input Voltage Range From DC24VDC to 70VDC Rated Current is (RMS) 10A 50-200 Watt Power Range Position, Speed, and Torque Control RS232 and CAN BUS Natural Air Cooling MODBUS and CANopen

More information

SEAT BELT CONTROL SYSTEM

SEAT BELT CONTROL SYSTEM RESTRAINTS SECTION SBC A SEAT BELT CONTROL SYSTEM B C D CONTENTS E PRECAUTION... 3 PRECAUTIONS... 3 Precaution for Supplemental Restraint System (SRS) "AIR BAG" and "SEAT BELT PRE-TEN- SIONER"...3 Precaution

More information

AGELKOM CAP04 Plasma and Oxy Fuel Torch height control for sheet metal cutting machines Height Sensor & Controller

AGELKOM CAP04 Plasma and Oxy Fuel Torch height control for sheet metal cutting machines Height Sensor & Controller 6 PIN INTERFACE HEIGHT CONTROL KNOB CAP 04 CAPACITIVE HEIGHT CONTROLLER DOWN IN POSITION UP TOUCH CABLE FAULT AGELKOM CAP04 Plasma and Oxy Fuel Torch height control for sheet metal cutting machines Height

More information

U1109-LOST COMMUNICATION WITH LIN STEERING WHEEL CONTROLS

U1109-LOST COMMUNICATION WITH LIN STEERING WHEEL CONTROLS 8 - KA - DODGE NITRO -.7L MAGNUM U9-LOST COMMUNICATION WITH LIN STEERING WHEEL CONTROLS BATT A FUSE M 5A MODULE- TOTALLY INTEGRATED POWER 9 C A99 8 9 C LIN BUS C CLUSTER A99 8 D5 WT/DG S5 S9 A99 8 D5 WT/DG

More information

1998 Crown Victoria/Grand Marquis Workshop Manual

1998 Crown Victoria/Grand Marquis Workshop Manual Section 17-01: Lighting, Exterior Workshop Manual DIAGNOSIS AND TESTING Procedure revision date: 03/16/1998 Headlamps (With Autolamps) Inspection and Verification 1. Verify the customer's concern by operating

More information

KNC-SRV-FD123-EA-000 Series Servo Driver

KNC-SRV-FD123-EA-000 Series Servo Driver FEATURES DESCRIPTION Input Voltage Range From DC24VDC to 70VDC Rated Current is (RMS) 10A 50-200 Watt Power Range Position, Speed, and Torque Control RS232 and Natural Air Cooling MODBUS and CANopen Standard

More information

Silvertel. Ag Features. 2 Description. Power-Over-Ethernet Module. IEEE802.3af compliant. Small SIL package size - 56mm (L) x 14mm (H) Low cost

Silvertel. Ag Features. 2 Description. Power-Over-Ethernet Module. IEEE802.3af compliant. Small SIL package size - 56mm (L) x 14mm (H) Low cost Silvertel V2.5 Feb 2014 Datasheet Pb 1 Features IEEE802.3af compliant Small SIL package size - 56mm (L) x 14mm (H) Low cost Input voltage range 36V to 57V Minimal (low cost) external components required

More information

OPERATOR S MANUAL HWH COMPUTER-CONTROLLED 2000 SERIES LEVELING SYSTEM. FEATURING: Single Step Touch Panel Control Air Leveling

OPERATOR S MANUAL HWH COMPUTER-CONTROLLED 2000 SERIES LEVELING SYSTEM. FEATURING: Single Step Touch Panel Control Air Leveling OPERATOR S MANUAL HWH COMPUTER-CONTROLLED 000 SERIES LEVELING SYSTEM R HWH CORPORATION R FEATURING: Single Step Touch Panel Control Air Leveling HWH COMPUTERIZED LEVELING LEVEL AIR EXCESS SLOPE MODE DUMP

More information

FAST XIM. XIM Unit Installation

FAST XIM. XIM Unit Installation 1 INSTRUCTIONS XIM Thank you for choosing products; we are proud to be your manufacturer of choice. Please read this instruction sheet carefully before beginning installation, and also take a moment to

More information

Additions, Revisions, or Updates

Additions, Revisions, or Updates 1 06 10-16 SUBJECT SPN 111 (CPC) (GHG17) and SPN 111 (CPC) (EPA07;EPA10;GHG14) DATE June 2016 Additions, Revisions, or Updates Publication Number / Title Platform Section Title Change DDC-SVC-MAN-0191

More information

GEMÜ 549 esydrive Motorized globe valve

GEMÜ 549 esydrive Motorized globe valve esydrive Motorized globe valve Features Linear or modified equal-percentage control characteristics High flow rates Force and speed are variably adjustable Extensive diagnostic facilities Operable via

More information

Service Guide: Power Supply Model

Service Guide: Power Supply Model Service Guide: Supply Model 153941 Note The Supply, converts, regulates and distributes electric power from the electrical mains supply to components installed on Midmark Dental Chairs. Contents: Accessing

More information

D2 - RAM 3500 PICKUP - 6.7L CUMMINS TURBO DIESEL

D2 - RAM 3500 PICKUP - 6.7L CUMMINS TURBO DIESEL 0 - D - RAM 00 PICKUP -.7L CUMMINS TURBO DIESEL PB-O SENSOR / CELL CIRCUIT OPEN BATT A0 B(+) ELECTRONICS TOTALLY INTEGRATED POWER FUSED IGNITION SWITCH OUTPUT (RUN-START) PORT LOW PORT HIGH POWER 7 C 7

More information

C965 V5.0 DISPLAY English

C965 V5.0 DISPLAY English C965 V5.0 DISPLAY User Manual Dillenger C965 Display - V5.0 Speed mode Speed display Speed unit Battery indicator Lamp PAS Level Brake Error Mileage mode Mileage information English Please read through

More information

Motorized Electric Latch Retraction

Motorized Electric Latch Retraction ; SECTION I: OVERVIEW 1. Description The Corbin Russwin MELR Electric Latch Retraction (ELR), refer to Figure 1, works with ED4000 & ED5000 Series exit devices to provide remote-controlled latch retraction

More information

Table of Contents. General Operation. 3 How Slam-A-Winner plays How the Wheel Scores How the Ball Lift works Programming Options...

Table of Contents. General Operation. 3 How Slam-A-Winner plays How the Wheel Scores How the Ball Lift works Programming Options... 61-MAN-B Table of Contents General Operation. 3 How Slam-A-Winner plays How the Wheel Scores How the Ball Lift works Programming Options... 4-6 Troubleshooting Guide. 7-8 Parts Identification 9 Schematics

More information

3 Installation of Display Unit > 3.5 Installation of Option Equipment

3 Installation of Display Unit > 3.5 Installation of Option Equipment W853:H-7ZCNA4160(included in CML-836-DC) Connect the W853 cable connector labeled P51 to the J51 connector on the PSU. Connect the W853 cable connector labeled P839 to the J839 connector on the RIF. Co-tighten

More information

Model INT July 2010

Model INT July 2010 / STM-1 Multiplexer / Demultiplexer Model T-9691 26 July 2010 Intronics, Incorporated 2020 Lafayette Boulevard Fredericksburg, Va 22401 (540) 898-4518 (Voice) (540) 898-3603 (Fax) http://www.intrnx.com

More information

HO MODULE HANDBOOK Fourth Edition - November 2009

HO MODULE HANDBOOK Fourth Edition - November 2009 HO MODULE HANDBOOK Fourth Edition - November 2009 HUB MS- OF /0/09 eference: Purpose: Concept: NMRA Standards and Recommended Practices, MS-.0, MRP-, MS-.3, MRP-.3, S9 To establish a uniform set of standards

More information

EN: This Datasheet is presented by the m anufacturer. Please v isit our website for pricing and availability at ore.hu.

EN: This Datasheet is presented by the m anufacturer. Please v isit our website for pricing and availability at   ore.hu. EN: This Datasheet is presented by the m anufacturer. Please v isit our website for pricing and availability at www.hest ore.hu. 1x1 Tab-DOWN RJ Description: /0 Base-TX RJ 1x1 Tab-DOWN with LEDs -pin (J0

More information

EasyStart. 364 (3 ton) Soft Starter 368 (6 ton) Soft Starter. Installation Manual

EasyStart. 364 (3 ton) Soft Starter 368 (6 ton) Soft Starter. Installation Manual EasyStart 364 (3 ton) Soft Starter 368 (6 ton) Soft Starter Installation Manual Micro-Air Corporation www.microair.net 124 Route 526 Phone (609) 259-2636 Allentown NJ 08501 Fax (609) 259-6601 Retrofit

More information