Security alarms, warning systems.

Size: px
Start display at page:

Download "Security alarms, warning systems."

Transcription

1 SIREN DRIVER BOARD. Free running siren activated by the application of a V DC power source. This module is capable of driving a maximum of 2 x 8 ohm 10W speakers and produces approximately 110 db at one metre. Security alarms, warning systems. Supply voltage - V DC. Output level db at one metre. Capacity - 2 x 8 ohm 10w horn speakers. Termination - 4 way screw terminal. Mounting - self-adhesive standoffs or housing. Reverse polarity protection on the V DC input. Back EMF diode protection on the speaker output. Red led indicates power is on and siren operating. +Vdc input MCM ELECTRICS PTY. LTD. LSP-PCBS1.PM4

2 FLASHER DC OUTPUT BOARD. On application of thev DC input, the output will be pulsed at 1HZ (maximum load of 1A). Security alarms, warning systems. Supply voltage Output level Capacity Termination Mounting - V DC. - Switching from gnd to V DC. - V 1A maximum. - 4 way screw terminal. - Self-adhesive standoffs or housing. Reverse polarity protection on the V DC input. Back EMF diode protection on the flasher output. Red led indicates power is on and output flashing. load MCM ELECTRICS PTY. LTD. LSP-PCBS2.PM4

3 FLASHER RELAY OUTPUT BOARD. On application of the V DC input, the output will be pulsed at 1HZ (maximum load of 1A). Relay will operate at a time constant of 0.5 seconds on and 0.5 seconds off. Security alarms, warning systems. Supply voltage - V DC. Output level - Switching from gnd to V DC. Capacity - V 1 AMP maximum Relay rating - Max. switching power 150W - Max. switching voltage 30V DC - Max. switching current 5A - Min. voltage and current 5V DC 0.1A Termination - 4 way screw terminal. Reverse polarity protection on the V DC input. Back EMF diode protection on the flasher output. Red led indicates power is on and output flashing. Voltage Free Contacts load Output V dc pulsed MCM ELECTRICS PTY. LTD. LSP-PCBS3.PM4

4 FUSE DISTRIBUTI BOARD. Upon application of the V DC in, there will be four individually fuse protected outputs rated at 2 AMPS each. Security alarms, any application requiring seperately fused supplies. Supply voltage Output Rating Termination Mounting - V DC. - V DC. at 2 AMPS way screw terminal. - self-adhesive standoffs or housing. Individual 2 AMP fuses on all four outputs. vdc OUT1 OUT3 OUT2 vdc vdc vdc OUT4 MCM ELECTRICS PTY. LTD. LSP-PCBS4.PM4

5 AC SPDT RELAY BOARD. On application of the 16V AC or V DC input, the relay will operate until the power is removed. Security alarms, any application requiring the operation of a spdt relay. Supply voltage - 16V AC/V DC. Relay rating - Max. switching power 150W - Max. switching voltage 30V DC - Max. switching current 5A Termination - 5 way screw terminal. Mounting - Self-adhesive standoffs or housing Red led indicates power is on and relay is energised Voltage Free Contacts MCM ELECTRICS PTY. LTD. LSP-PCBS5.PM4

6 DC SPDT RELAY BOARD. On application of the V DC input, the relay will operate until the V DC is removed. Security alarms, any application requiring the operation of a spdt relay. Supply voltage - V DC. Relay rating - Max. switching power 150W - Max. switching voltage 30V DC - Max. switching current 5A Termination - 5 way screw terminal. Reverse polarity protection on the V DC input. Red led indicates power is on and relay is energised. Voltage Free Contacts MCM ELECTRICS PTY. LTD. LSP-PCBS6.PM4

7 AC DPDT RELAY BOARD. On application of the 16V AC or V DC input, the relay will operate until the power is removed. Security alarms, any application requiring the operation of a dpdt relay. Supply voltage - 16V AC/V DC. Relay rating - Max. switching power 60W - Max. switching voltage 220V DC - Max. switching current 2A - Max. Carrying current 3A Termination - 8 way screw terminal. Mounting - Self-adhesive standoffs or housing Red led indicates power is on and relay is energised. Voltage Free Contacts MCM ELECTRICS PTY. LTD. LSP-PCBS7.PM4

8 DC DPDT RELAY BOARD. On application of the V DC input, the relay will operate until the V DC is removed. Security alarms, any application requiring the operation of a dpdt relay. Supply voltage - V DC Relay rating - Max. switching power 60W Max. switching voltage 220V DC Max. switching current 2A Max. carrying current 3A Termination - 8 way screw terminal. Reverse polarity protection on the V DC input. Red led indicates power is on and relay is energised. output led Voltage Free Contacts MCM ELECTRICS PTY. LTD. LSP-PCBS8.PM4

9 CLUTCH RELAY BOARD. On power up the relay will not be energised. On application of +V DC to the +TR terminal or 0V to the -TR terminal the relay will toggle once. On subsequent triggering the relay will toggle again. Security alarms, any application requiring the use of multiple push buttons, keyswitches, coded entry units. Supply voltage - V DC Relay rating - Max. switching power 150W Max. switching voltage 30V DC Max. switching current 5A Min. voltage and current 5V DC 0.1A Termination - 8 way screw terminal. Reverse polarity protection on the V DC input. Red led indicates power is on and relay is energised. Voltage Free Contacts MCM ELECTRICS PTY. LTD. LSP-PCBS9.PM4

10 TIMER BOARD. 1 of 2 Options: Delay to operate timer. Operate, delay to release timer. * Delay to operate: Link LK1 position 2. Upon application of a positive or negative trigger the relay will remain de-energised for a period of time dependant on the setting of the dipswitches. * Delay to release: Link LK1 position 3. Upon application of a positive or negative trigger the relay will energise energised for a period of time dependant on the setting of the dipswitches. Security alarms, any application requiring the operation of a SPDT relay for a period of time or after a specified time. Supply voltage- V DC Relay rating - Max. switching power 150W Max. switching voltage 30V DC Max. switching current 5A Termination - 8 way screw terminal. Reverse polarity protection on the V DC input. Red led indicates relay is energised. +RST - Not used. -TR - Negative trigger (0-3V). +TR - Positive trigger (7-V). Pot Adjustments position 1 position 2 position 3 LK1 RV1 SW1 Min Max Voltage Free Contacts MCM ELECTRICS PTY. LTD.

11 2 Minimum Minimum Maximum Maximum Dipswitch Settings Dipswitch Settings Potentiometer Adjustments Potentiometer Adjustments Seconds Seconds TIMER BOARD. TIMER BOARD Minutes Minutes Minutes Minutes Seconds Seconds MCM ELECTRICS PTY. LTD. MCM ELECTRICS PTY. LTD.

12 FULL FUNCTI TIMER / CLUTCH BOARD. 1 of 2 Options: Delay to operate timer. Operate, delay to release timer. Clutch relay * Timer - Delay to operate: Link LK1 position 2. Upon application of a positive or negative trigger the relay will remain de-energised for a period of time dependant on the setting of the dipswitches. * Timer - Delay to release: Link LK1 position 3. Upon application of a positive or negative trigger the relay will energise energised for a period of time dependant on the setting of the dipswitches. * Clutch relay: Link LK1 position 1. On power up the relay will not be energised. On application of +V DC to the +TR terminal or 0V to the -TR terminal the relay will toggle once. On subsequent triggering the relay will toggle again. Supply voltage - V DC Relay rating - Max. switching power 150W Max. switching voltage 30V DC Max. switching current 5A Termination - 8 way screw terminal. Reverse polarity protection on the V DC input. Red led indicates relay is energised. +RST - Not used. -TR - Negative trigger (0-3V). +TR - Positive trigger (7-V). Pot Adjustments position 1 position 2 position 3 LK1 RV1 SW1 Min Max Voltage Free Contacts MCM ELECTRICS PTY. LTD. LSP-PCBS.PM4

13 1AMP POWER SUPPLY BOARD. 1 Amp 13.7 Volts DC power supply, open collector outputs via 10 ohm resistors for Mains Fail and Mains On. Battery output for Battery backup. Security alarms, any application requiring 13.7 Vdc at 1 Amp. Supply Voltage - 16V AC. Output Voltage - Factory set to 13.7 Vdc. Battery Voltage Vdc (Current Limited). Termination - 8 way screw terminal. Varistor across AC input, 2 Amp fuse protected DC output, Battery output is Current Limited for protection. Red led indicates Mains on. 10 ohm Mains on 0V 10 ohm Mains fail 0V Mains fail and Mains on output stage. Mains on Mains fail load MCM ELECTRICS PTY. LTD. LSP-PCBS13.PM4

14 MICROPHE PRE-AMP BOARD. Security alarms, any application requiring 13.7 Vdc at 1 Amp. Supply Voltage - V DC. Termination - 3 way screw terminal. Mounting - Affixed to electrical wall plate by MCM. Varistor across AC input, 2 Amp fuse protected DC output, Battery output is Current Limited for protection. Red led indicates Mains on. Microphone Input input +V dc To amplifier MCM ELECTRICS PTY. LTD. LSP-PCBS14.PM4

15 1AMP POWER SUPPLY BOARD. 1 Amp 13.7 Volts DC power supply, open collector outputs via 10 ohm resistors for Mains Fail and Mains On. Battery output for Battery backup. Security alarms, any application requiring 13.7 Vdc at 1 Amp. Supply Voltage - 16V AC. Output Voltage - Factory set to 13.7 Vdc. Battery Voltage Vdc (Current Limited). Termination - 8 way screw terminal. Varistor across AC input, 2 Amp fuse protected DC output, Battery output is Current Limited for protection. Red led indicates Mains on. +RST - Not used. -TR - Negative trigger (0-3V). +TR - Positive trigger (7-V). Pot Adjustments position 1 position 2 position 3 LK1 RV1 SW1 Min Max Voltage Free Contacts MCM ELECTRICS PTY. LTD. LSP-PCBS15.PM4

PRODUCT / TEST MANUAL 2L9K2 BATTERY EARTH FAULT RELAY

PRODUCT / TEST MANUAL 2L9K2 BATTERY EARTH FAULT RELAY Sheet 1 of 5 Order Number Serial Number PRODUCT / TEST MANUAL 2L9K2 BATTERY EARTH FAULT RELAY Issue Date Level B 27/05/1999 Initial issue. Summary of changes Due to RMS continuous product improvement policy

More information

ELECTRIC SCHEMATICS LS1 LS2. "1532ES / 1932ES" Service & Parts Manual - ANSI Specifications March 2008 Page 5-9 ART_2236 ART_2243

ELECTRIC SCHEMATICS LS1 LS2. 1532ES / 1932ES Service & Parts Manual - ANSI Specifications March 2008 Page 5-9 ART_2236 ART_2243 ELECTRIC SCHEMATICS NOTES: (Unless otherwise specified). Switch S BASE/PLATFORM makes contact from the CENTER to the LEFT position when placed in BASE.. Switch S UP/DOWN makes contact from the CENTER to

More information

J1 Plug Pin Identification

J1 Plug Pin Identification D5 D D D D5 D ART_ J D D0 R R R R TB 0 D D D D D D J Plug Pin Identification PIN # WIRE # SIGNAL FUNCTION 0 INPUT Drive Reverse INPUT Drive Forward OUTPUT Brake, Decel Valve signal INPUT Steer Left 5 OUTPUT

More information

Ride On Locomotive. Installation Guide

Ride On Locomotive. Installation Guide Ride On Locomotive Installation Guide Phoenix Sound Systems, Inc. 3514 West Liberty Road Ann Arbor MI 48103 www.phoenixsound.com phone: 800-651-2444 fax: 734-662-0809 e-mail: phoenixsound@phoenixsound.com

More information

Security and Keyless Entry Installation Guide ca 1051

Security and Keyless Entry Installation Guide ca 1051 PROFESSIONAL SERIES Security and Keyless Entry Installation Guide ca 1051 ca1051 rev B. 2011 Audiovox Electronics Corporation. All rights reserved. 1 Table of Contents Before You Begin... 3 Wire Connection

More information

Systems: Electronics

Systems: Electronics Systems: Electronics Resistors & Capacitors Units for resistors and capacitors size/component small large resistance ohm kilohm megaohm capacitance picofarad microfarad farad current milliampere Ampere

More information

SERIES 700/700E FACTORY KEYLESS UPGRADE INSTALLATION MANUAL

SERIES 700/700E FACTORY KEYLESS UPGRADE INSTALLATION MANUAL SERIES 700/700E FACTORY KEYLESS UPGRADE INSTALLATION MANUAL Items Supplied with the System: Installation Instructions: Main unit 1. Mounting the module: Plug In LED Mount the module in a suitable location

More information

INSTALLATION INSTRUCTIONS FOR PART TRIGGER TRIGGER

INSTALLATION INSTRUCTIONS FOR PART TRIGGER TRIGGER 6 2.5 1.5 ISO M4 M5 M3 WIRE CUTTER INSTALLATION INSTRUCTIONS FOR PART TRIGGER TRIGGER The Trigger is a universal module that provides 15 different preset functions that are activated from a positive or

More information

J1 Plug Pin Identification

J1 Plug Pin Identification D D8 D D D D ART_8 J 8 D D0 R R R R TB 80 D D D D D D J Plug Pin Identification PIN # WIRE # SIGNAL FUNCTION 0 INPUT Drive Reverse INPUT Drive Forward OUTPUT Brake, Decel Valve signal 8 INPUT Steer Left

More information

J1 Plug Pin Identification

J1 Plug Pin Identification D5 D8 D7 D4 D5 D ART_8 J 4 8 D D0 7 R R R R4 TB 80 D D D D4 D D J Plug Pin Identification PIN # WIRE # SIGNAL FUNCTION 0 INPUT Drive Reverse INPUT Drive Forward OUTPUT Brake, Decel Valve signal 4 8 INPUT

More information

Single or Double 240VAC motor control for domestic and industrial gates and doors.

Single or Double 240VAC motor control for domestic and industrial gates and doors. COBO30 Double 240V Motor Drive Controller Features For 240Volt Motors Auto Closing Open Only Security Closing and Extended Lock Pulse (user selectable) Travel Timer Push Button Input Photo Cell Input Option

More information

Installation Instructions

Installation Instructions F20/F25 Installation Instructions PROFESSIONAL INSTALLATION STRONGLY RECOMMENDED Installation Precautions: Roll down window to avoid locking keys in vehicle during installation Avoid mounting components

More information

e-ask electronic Access Security Keyless-entry

e-ask electronic Access Security Keyless-entry e-ask electronic Access Security Keyless-entry Multiplex System Multiplex System Installation & Instructions (UM15 ~ 22272-03) Table of Contents Introduction... 1 Standard e-fob Operation and Features...

More information

702 AUTOMATIC START MODULE OPERATING INSTRUCTIONS

702 AUTOMATIC START MODULE OPERATING INSTRUCTIONS 702 AUTOMATIC START MODULE OPERATING INSTRUCTIONS > TABLE OF CONTENTS 1 DESCRIPTION OF OPERATION... 4 1.1 MANUAL MODE OPERATION... 4 1.2 AUTOMATIC MODE OF OPERATION...

More information

ENFORCER TM 6201-IQ ELECTRONIC SIREN

ENFORCER TM 6201-IQ ELECTRONIC SIREN ENFORCER TM 6201-IQ ELECTRONIC SIREN INSTALLATION & OPERATION MANUAL CONTENT PAGE UNPACKING 2 INTRODUCTION 2 STANDARD FEATURES 2 INSTALLATION & MOUNTING 3 MOUNTING THE ENFORCER TM 6201 3 WIRING & ADJUSTMENTS

More information

PSM72H Push-Button Start Module

PSM72H Push-Button Start Module Capricorn Controls DA02PSM72H1-2 Data & Application Note Page 1 of 6 PSM72H Push-Button Start Module Genset Controls - Timers/Monitors/Trips - Battery Charging Spares & Accessories - Custom Products Ultra

More information

InteliCharger V 20A Intelligent Automatic Battery Charger

InteliCharger V 20A Intelligent Automatic Battery Charger InteliCharger InteliCharger 500 24V 20A Intelligent Automatic Battery Charger September 2012 Reference Guide TABLE OF CONTENTS 1 Document information... 2 2 EQUIPMENT RATING... 3 3 ENVIRONMENT... 3 4 PROTECTION...

More information

SECURITY DOOR CONTROLS

SECURITY DOOR CONTROLS CR4 FOUR STATION CONTROL MODULE The CR4 module operates on 12V or 24V DC and provides control of four (4) stations. Each CR4 station accepts a Dry () trigger input and provides one (1) Fused 2 Amp SPDT

More information

LINEAR ACTUATOR INDUSTRIAL DUTY LACT SERIES

LINEAR ACTUATOR INDUSTRIAL DUTY LACT SERIES Product Data Sheet Standard Features: All steel frame and extension tube o Aluminum gearbox housing o Ball screw version has stainless steel extension tube Nominal stroke lengths: 4 [102mm], 6 [152mm],

More information

GCU-10. Automatic Engine Control Unit Operators Manual

GCU-10. Automatic Engine Control Unit Operators Manual GCU-10 Automatic Engine Control Unit Operators Manual KUTAI ELECTRONICS INDUSTRY CO., LTD. TEL : +886-7-8121771 FAX : +886-7-8121775 Website : www.kutai.com.tw Headquarters : No.3, Lane 201, Chien Fu St.,

More information

Covers All 430, 440, 441 and CJ Series Advanced Security Systems.

Covers All 430, 440, 441 and CJ Series Advanced Security Systems. INSTALL GUIDE Covers All 430, 440, 441 and CJ Series Advanced Security Systems www.ultrastarters.com Technical Support: 866-698-5872 ext 0 support@ultrastarters.com FCC/ID Notice This device complies with

More information

STARTER DISABLE/ KEYLESS ENTRY SYSTEM

STARTER DISABLE/ KEYLESS ENTRY SYSTEM I N S T A L L A T I O N M A N U A L STARTER DISABLE/ KEYLESS ENTRY SYSTEM BEFORE INSTALLING THE STARTER DISABLE/KEYLESS ENTRY SYSTEM DO read through this installation manual. DO NOT install the control

More information

2122H. Arm Field Arm Field 1/8-1/ / /8-1/ / / /

2122H. Arm Field Arm Field 1/8-1/ / /8-1/ / / / Non-Regen Drives Non-regenerative drives are typically used on applications which primarily motor in one direction and stopping is achieved through friction or infrequent use of a dynamic braking resistor.

More information

8803214-8803999 DIODE BOARD The diode board is located inside the lower control box. D15 D8 D7 D14 D5 D13 ART_2181 J1 14 8 D9 D10 7 1 R2 R1 R3 R4 TB1 8601 D11 D3 D12 D4 D1 D2 J1 Plug Pin Identification

More information

DIODE BOARD The diode board is located inside the lower control box. D15 D8 D7 D14 D5 D13 ART_2181 J1 14 8 D9 D10 7 1 R2 R1 R3 R4 TB1 8601 D11 D3 D12 D4 D1 D2 J1 Plug Pin Identification PIN # WIRE # SIGNAL

More information

2 WAY REMOTE STARTER & ALARM SYSTEM INSTALLATION GUIDE FCC ID NOTICE

2 WAY REMOTE STARTER & ALARM SYSTEM INSTALLATION GUIDE FCC ID NOTICE REV. ARS. WAY REMOTE STARTER & ALARM SYSTEM INSTALLATION GUIDE FCC ID NOTICE This device complies with Part 5 of the FCC rules. Operation is subject to the following conditions:. This device may not cause

More information

ELSEMA Single / Double Gate Controller, with Battery Charger, for 12V / 24V Motor, Enclosed, GATCOxxxCH

ELSEMA Single / Double Gate Controller, with Battery Charger, for 12V / 24V Motor, Enclosed, GATCOxxxCH GATCO12SCH, GATCO24SCH, GATCO12DCH, GATCO24DCH Single / Double Gate Controller, with Battery Charger, for 12V / 24V Motor Features 4 Versions: GATCO12SCH 12V Single motor GATCO24SCH 24V Single motor GATCO12DCH

More information

INSTALLATION MANUAL. Model: PLUS For Technical Assistance, please call (800) , or visit

INSTALLATION MANUAL. Model: PLUS For Technical Assistance, please call (800) , or visit R Vehicle Security INSTALLATION MANUAL Model: PLUS-4700 This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference;

More information

AR12 & AR20 Wiring diagram (multifunction display)

AR12 & AR20 Wiring diagram (multifunction display) Wiring diagram (multifunction display) Multifunction display (diesel level, engine monitor, operating hours counter) Wiring diagram (engine start/stop) Battery, ignition switch, starter, alternator Stop

More information

DEEP SEA ELECTRONICS PLC

DEEP SEA ELECTRONICS PLC DEEP SEA ELECTRONICS PLC 703 AUTOMATIC START MODULE OPERATING INSTRUCTIONS Author:- John Ruddock 703 Operating Instructions Issue Beta1 25/08/2003 2:45 PM JR - 1 - >

More information

Remote Start with Keyless Entry Installation Guide ca5054

Remote Start with Keyless Entry Installation Guide ca5054 PROFESSIONAL SERIES Remote Start with Keyless Entry Installation Guide ca5054 2014 Voxx Electronics Corporation. All rights reserved. 1 Table of Contents Before You Begin...3 Wire Connection Guide...4

More information

DEEP SEA ELECTRONICS PLC

DEEP SEA ELECTRONICS PLC COMPLEX SOLUTIONS MADE SIMPLE DEEP SEA ELECTRONICS PLC DSE704 AUTOSTART CONTROL MODULE OPERATING MANUAL 057-042 704 Operating Instructions Issue 2.1 18/06/2007 11:27:00 JR - 1 - Deep Sea Electronics Plc

More information

FM SECURITY AND REMOTE START SYSTEM

FM SECURITY AND REMOTE START SYSTEM FM SECURITY AND REMOTE START SYSTEM INSTALLATION MANUAL BEFORE INSTALLING THIS PRODUCT PLEASE READ THIS INSTALLATION MANUAL THOROUGHLY!! This system is intended for installation on vehicles equipped with

More information

DLA SERIES + ACCESSORIES

DLA SERIES + ACCESSORIES LINEAR ACTUATORS SERIES + ACCESSORIES 50 mm to 300 mm stroke 10 N series 50-300 mm 0-10 N 95 Ø40 9 Extracted - - Example: --5-A-50- Reduction 5 10 30 40 Voltage (VDC) / / / / / Max. thrust (N) 0 300 500

More information

Switch Machines Installation & Wiring

Switch Machines Installation & Wiring Switch Machines Installation & Wiring Conventional Twin Coil Switch Machines Electrically: In use since developed by Walthers in early 1930 s Long time standard for remote operation Currently: Rix, Atlas,

More information

Aura CM-55i Flush Mount Illuminated Enclosure Installation Instructions

Aura CM-55i Flush Mount Illuminated Enclosure Installation Instructions Aura CM-55i Flush Mount Illuminated Enclosure Installation Instructions Section General Description Camden Aura, Model CM-55i provide the Industry s st Changing State illuminated switch enclosures. They

More information

LINEAR ACTUATOR INDUSTRIAL DUTY 10A/B SERIES

LINEAR ACTUATOR INDUSTRIAL DUTY 10A/B SERIES Product Data Sheet Standard Features: All steel frame and extension tube o Aluminum gearbox housing o Ball screw version has stainless steel extension tube Nominal stroke lengths: 4 [102mm], 6 [153mm],

More information

Ultrasonic Sensor U-B

Ultrasonic Sensor U-B MAINTAIN CONSTANT TENSION - The ultrasonic sensor is used to maintain constant tension when using a brake for producing unwind (payout) tension, or when using a clutch for rewind tension. The sensor measures

More information

LINEAR ACTUATOR INDUSTRIAL DUTY LACT BALL SCREW DRIVE

LINEAR ACTUATOR INDUSTRIAL DUTY LACT BALL SCREW DRIVE Product Data Sheet LINEAR ACTUATOR Standard Features: All steel frame with stainless steel extension tube o Aluminum gearbox housing Nominal stroke lengths: 4 [102mm], 6 [152mm], 8 [203mm], 12 [305mm],

More information

Explanation 1 Input External Switch 2 Input Hipot Safety Switch

Explanation 1 Input External Switch 2 Input Hipot Safety Switch on the 1100H+ The 1100H+ has capability, which allows you to set up the tester to control external devices with tester functions. You can also use an input on the tester to start a test. For example, the

More information

ADD-ON REMOTE STARTER TO AFTERMARKET SYSTEM

ADD-ON REMOTE STARTER TO AFTERMARKET SYSTEM MEGATRONIX RS 110 ADD-ON REMOTE STARTER TO AFTERMARKET SYSTEM Installation and Operation Manual MEGATRONIX CHATSWORTH, CA U.S.A. RS110 ADD-ON REMOTE CAR STARTER For Vehicles Equipped With Automatic Transmission

More information

Price List May Realism is what we aspire to achieve. This List gives you an idea of what else we do.

Price List May Realism is what we aspire to achieve. This List gives you an idea of what else we do. Brimal also supply a complete range of Electronic Components and Tools for your hobby. Please ring 01429 297277 for all sales. This List gives you an idea of what else we do. Audio Cable PCB Terminals

More information

MODEL RMS INSTALLATION INSTRUCTIONS. CONTENTS Page A. Introduction 1. Usage 2 2. How it operates 2

MODEL RMS INSTALLATION INSTRUCTIONS. CONTENTS Page A. Introduction 1. Usage 2 2. How it operates 2 CONVEYOR COMPONENTS COMPANY Division of Material Control, Inc. 130 Seltzer Road, PO Box 167 Croswell, MI 48422 USA PHONE: (810) 679-4211 TOLL FREE (800) 233-3233 FAX: (810) 679-4510 Email: info@conveyorcomponents.com

More information

AA4006 Speed Sensitive Trip Unit. User Manual

AA4006 Speed Sensitive Trip Unit. User Manual AA4006 Speed Sensitive Trip Unit User Manual Software Version 2.00 Issued 01/2005 Don Controls Limited Westfield Industrial Estate Kirk Lane, Yeadon Leeds, LS19 7LX Telephone: +44 (0)845 1304946 Fax: +44

More information

Professional Wireless Products

Professional Wireless Products Page 1 of 6 093115 Communications Power Supply and Battery Management Controller Page 2 of 6 1.0 Introduction The 093115 is a 13.8 volt 15amp transformer isolated switch mode down converter designed to

More information

FIRE DOOR OPERATOR WARNING INSTALLATION LOGIC BOARD REPLACEMENT KIT K , K A-400 & K B-400 APPLICATION REMOVE AC AND DC POWER

FIRE DOOR OPERATOR WARNING INSTALLATION LOGIC BOARD REPLACEMENT KIT K , K A-400 & K B-400 APPLICATION REMOVE AC AND DC POWER APPLICATION Replacement of logic board for Models FDO and FDC operators with Rev. 400 wiring. FIRE DOOR OPERATOR LOGIC BOARD REPLACEMENT KIT K79-3493-400, K79-3493A-400 & K79-3493B-400 WARNING To prevent

More information

INSTALLATION GUIDE. FCC ID NOTICE

INSTALLATION GUIDE.  FCC ID NOTICE REV.5 RS. ADVANCED REMOTE STARTER INSTALLATION GUIDE www.security.soundstream.com FCC ID NOTICE This device complies with Part 5 of the FCC rules. Operation is subject to the following conditions:. This

More information

INSTALLATION, OPERATION & MAINTENANCE SERIES ABC11B-120-XX BATTERY CHARGERS

INSTALLATION, OPERATION & MAINTENANCE SERIES ABC11B-120-XX BATTERY CHARGERS MANUAL NUMBER: 64073 REV: 2 DATE: October 3, 2006 INSTALLATION, OPERATION & MAINTENANCE SERIES ABC11B-120-XX BATTERY CHARGERS AMERICAN BATTERY CHARGING, INC. P.O. BOX 17040 28 MAPLE AVENUE SMITHFIELD,

More information

INSTALLATION MANUAL. Remote Mobile Security System. Model: PL30

INSTALLATION MANUAL. Remote Mobile Security System. Model: PL30 Remote Mobile Security System INSTALLATION MANUAL Model: PL30 Copyright 1998 Magnadyne Corporation For Technical Assistance (800) 638-3600 For Fax on Demand Technical Assistance (800) 994-9977 (Must be

More information

Vehicle Alarm System With Channel 2 Auxiliary Output Installation Instructions

Vehicle Alarm System With Channel 2 Auxiliary Output Installation Instructions Model PRO 9842 Installation Manual Vehicle Alarm System With Channel 2 Auxiliary Output Installation Instructions This Unit Is Intended For Installation In Vehicles With 12 Volt Negative Ground Electrical

More information

Remote Start with Keyless Entry Installation Guide CA 5051

Remote Start with Keyless Entry Installation Guide CA 5051 PROFESSIONAL SERIES Remote Start with Keyless Entry Installation Guide CA 5051 2010 Audiovox Electronics Corporation. All rights reserved. 1 Table of Contents Before You Begin... 3 Wire Connection Guide...

More information

Aura CM-54i Surface Mount Illuminated Enclosure

Aura CM-54i Surface Mount Illuminated Enclosure Door Activation Devices Aura CM-54i Surface Mount Illuminated Enclosure Package Contents 1 CM 54i 1 Blue/Green/Red Aura PCB 2 # 6 X 3/8 Screws 1. GENERAL DESCRIPTION Camden Aura, Model CM-54i provide the

More information

FEB.20, 2003 COMMANDO MODEL FM-870 REMOTE ENGINE STARTER WITH ALARM SYSTEM INSTALLATION MANUAL RST872 1

FEB.20, 2003 COMMANDO MODEL FM-870 REMOTE ENGINE STARTER WITH ALARM SYSTEM INSTALLATION MANUAL RST872 1 COMMANDO MODEL FM-0 REMOTE ENGINE STARTER WITH ALARM SYSTEM INSTALLATION MANUAL RST2 1 HJKL TABLE OF CONTENTS: INSTALLATION DIAGRAM..... 4 H1: 6 PIN HEAVY GAUGE WIRING CONNECTION.... 6 H1/1 Violet Wire

More information

LINEAR ACTUATOR INDUSTRIAL DUTY LACT ACME DRIVE SERIES

LINEAR ACTUATOR INDUSTRIAL DUTY LACT ACME DRIVE SERIES Product Data Sheet LINEAR ACTUATOR Standard Features: All steel frame and extension tube o Aluminum gearbox housing Nominal stroke lengths: 4 [102mm], 6 [152mm], 8 [203mm], 12 [305mm], 18 [457mm], 24 [610mm],

More information

Troubleshooting Guide

Troubleshooting Guide Troubleshooting Guide RV-C System Layout BCM Pin Values Tanks Interior Lighting I/O Exterior Lighting I/O Pin Name BCM Function Note A DMM 1 Fresh 1 Tank In Input from Sending Unit 2 Fresh 2 Tank In Input

More information

DMX-A2-DRV Integrated Advanced Step Motor Driver

DMX-A2-DRV Integrated Advanced Step Motor Driver DMX-A2-DRV Integrated Advanced Step Motor Driver DMX-A2-DRV Manual page 1 rev 3.10 COPYRIGHT 2008 ARCUS, ALL RIGHTS RESERVED First edition, May 2008 ARCUS TECHNOLOGY copyrights this document. You may not

More information

Model PRO 9246CH Installation Manual

Model PRO 9246CH Installation Manual Model PRO 9246CH Installation Manual PRE-INSTALLATION NOTES: RF Programmable Features : Feature Selection 1 Flash 2 Flash 3 Flash Default 1st Do L/UL 1 Sec. 3.5 Sec. 1 Sec L, Dbl. U/L 1 Sec. 2nd Accy Lock

More information

2 Way Security and Keyless Entry Installation Guide ca 1553

2 Way Security and Keyless Entry Installation Guide ca 1553 PROFESSIONAL SERIES 2 Way Security and Keyless Entry Installation Guide ca 1553 2012 Audiovox Electronics Corporation. All rights reserved. 1 Table of Contents Before You Begin... 3 Wire Connection Guide...

More information

60 Series Engine Controls

60 Series Engine Controls ECU 60 Series Engine Controls Use CAUTION since you are applying 120VAC RMS to the AC Input terminals and that it is always potentially their during engine run!!! ECU is a registered trademark of Engineering

More information

SECURITY SYSTEM INSTALLATION MANUAL

SECURITY SYSTEM INSTALLATION MANUAL INSTALLATION MANUAL SECURITY SYSTEM BEFORE INSTALLING THE SYTEM DO read through this installation manual. DO NOT install the alarm brain in an engine compartment. The alarm may arm itself when power is

More information

PROTEC P1300-S/P1350-S Siren & Light Controller

PROTEC P1300-S/P1350-S Siren & Light Controller PROTEC P1300-S/P1350-S Siren & Light Controller Installation & Wiring Manual Table of Contents Introduction... 2 General Warnings... 3 Unpacking &Pre-Installation Check... 3 Installation & Mounting...

More information

NEW ZEALAND POST OFFICE NEGATIVE 50V D.C. TO POSITIVE 50V D.C. SUPPLY NOTES PR 2157 ISSUE 1 APRIL 1977

NEW ZEALAND POST OFFICE NEGATIVE 50V D.C. TO POSITIVE 50V D.C. SUPPLY NOTES PR 2157 ISSUE 1 APRIL 1977 NEW ZEALAND POST OFFICE NEGATIVE 50V D.C. TO POSITIVE 50V D.C. SUPPLY NOTES PR 2157 ISSUE 1 APRIL 1977 1. GENERAL. 1.1 These PR notes supersede notes PR 2133 and should only be used in conjunction with

More information

ALARM UPGRADE FOR FACTORY REMOTE KEYLESS ENTRY SYSTEM INSTALLATION PRECAUTIONS & WARNINGS

ALARM UPGRADE FOR FACTORY REMOTE KEYLESS ENTRY SYSTEM INSTALLATION PRECAUTIONS & WARNINGS CS-882 OEM ALARM UPGRADE FOR FACTORY REMOTE KEYLESS ENTRY SYSTEM INSTALLATI PRECAUTIS & WARNINGS NOTE: This system does not improve or affect the range of the factory remote keyless entry transmitters.

More information

ARCHITECTURAL DOOR HARDWARE POWER SUPPLIES & TRANSFORMER CATALOG

ARCHITECTURAL DOOR HARDWARE POWER SUPPLIES & TRANSFORMER CATALOG ARCHITECTURAL DOOR HARDWARE POWER SUPPLIES & TRANSFORMER CATALOG January 1, 2017 v3 West Coast Office (800) 544-4422 East Coast Office (800) 225-6737 intldoorclosers.com Index POWER SUPPLIES & TRANSFORMERS

More information

Electropneumatic Timing Relays Series 7000 Industrial

Electropneumatic Timing Relays Series 7000 Industrial DESIGN FEATURES Available in On-Delay, True Off-Delay, and On/Off-Delay. Timing from 0.1 seconds to 60 minutes, fully calibrated in linear increments. Oversize time-calibrated adjustment knobs, serrated

More information

LINEAR ACTUATOR INDUSTRIAL DUTY 10A SERIES

LINEAR ACTUATOR INDUSTRIAL DUTY 10A SERIES Product Data Sheet LINEAR ACTUATOR Standard Features: All steel frame and extension tube o Aluminum gearbox housing Nominal stroke lengths: 4 [102mm], 6 [153mm], 8 [203mm], 12 [305mm], 18 [457mm], 24 [610mm],

More information

Model 930 Power Control System Instruction Manual

Model 930 Power Control System Instruction Manual Model 930 Power Control System Instruction Manual Publication No. A105328-001 Rev A December 2000 Another quality product from: 7128 Shady Oak Rd, Eden Prairie MN 55344 Phone: (952) 949-9009 Fax: (952)

More information

3 Channel Remote Start / Keyless Entry System Installation Instructions

3 Channel Remote Start / Keyless Entry System Installation Instructions Model AA-RS5CS Installation Manual 3 Channel Remote Start / Keyless Entry System Installation Instructions This Unit Is Intended For Installation In Vehicles With 12 Volt Negative Ground Electrical Systems,

More information

PPS20 COMMUNICATIONS POWER SUPPLY AND BATTERY MANAGEMENT SYSTEM

PPS20 COMMUNICATIONS POWER SUPPLY AND BATTERY MANAGEMENT SYSTEM PPS20 COMMUNICATIONS POWER SUPPLY AND BATTERY MANAGEMENT SYSTEM 2 Table of Contents Introduction:... 3 1.0: Operation Principles:... 3 1.1: Stand alone supply... 3 1.2: Backed up supply:... 3 1.3: Battery

More information

MM1 Installation Instructions

MM1 Installation Instructions MM1 Installation Instructions PROFESSIONAL INSTALLATION STRONGLY RECOMMENDED Installation Precautions: Roll down window to avoid locking keys in vehicle during installation Avoid mounting components or

More information

Security and Remote Start Installation Guide for models: ca 6552 ca 6552 SST

Security and Remote Start Installation Guide for models: ca 6552 ca 6552 SST PROFESSIONAL SERIES Security and Remote Start Installation Guide for models: ca 6552 ca 6552 SST ca6552/6552sst. 2011 Audiovox Electronics Corporation. All rights reserved. 1 Table of Contents Before You

More information

Automatic / Manual Transmission Remote Start with Keyless Entry Installation Guide for models: ca5153 ca5153sst

Automatic / Manual Transmission Remote Start with Keyless Entry Installation Guide for models: ca5153 ca5153sst PROFESSIONAL SERIES Automatic / Manual Transmission Remote Start with Keyless Entry Installation Guide for models: ca5153 ca5153sst 2012 Audiovox Electronics Corporation. All rights reserved. 1 Table of

More information

LAN Power Supply Module.

LAN Power Supply Module. Revision 1.1 Sept. 2002 1 Contents Model 3000 / Access 4000 LAN Power Supply Module. Standard: P/N: 995050 Enhanced: P/N: 995050ENH INSTALLATION MANUAL Overview... 1 System Requirements and Reporting...

More information

CSI-400 Installation Instructions

CSI-400 Installation Instructions CSI-400 Installation Instructions Kit Contents Installation Precautions: Roll down window to avoid locking keys in vehicle during installation Avoid mounting components or routing wires near hot surfaces

More information

6R / 5-BUTTON SERIES VEHICLE SECURITY SYSTEM

6R / 5-BUTTON SERIES VEHICLE SECURITY SYSTEM 6R / 5-BUTTON SERIES VEHICLE SECURITY SYSTEM Button 1 Button 2 Button 5 Button 3 Button 4 Standard Features: Two 5-Button Remote Transmitters Status indicator (LED) Valet / override switch Multi-tone siren

More information

Product Instruction. Door Control Board: Board 1Ø4 for PM/SSC (R3)

Product Instruction. Door Control Board: Board 1Ø4 for PM/SSC (R3) Door Control Board: Board 1Ø4 for PM/SSC 61111-149 (R3) 2000-08-31 2000, 1992 KONE Inc. Unpublished work. All rights reserved. No portion of this volume may be used or reproduced in any manner without

More information

FINDER RELAYS & MODULAR TIMERS IN STOCK AT MARSH ELECTRONICS

FINDER RELAYS & MODULAR TIMERS IN STOCK AT MARSH ELECTRONICS Finder relays, modular timers and accessories in stock at FINDER RELAYS & MODULAR TIMERS IN STOCK AT MARSH ELECTRONICS Finder Relay has hundreds of possible combinations of relays and modular timers. Those

More information

Aura CM-54i Surface Mount Illuminated Enclosure Installation Instructions

Aura CM-54i Surface Mount Illuminated Enclosure Installation Instructions Aura CM-54i Surface Mount Illuminated Enclosure Installation Instructions 2 Section General Description Camden Aura, Model CM-54i provide the Industry s st Changing State illuminated switch enclosures.

More information

Fincor DC Drives. Flexible & Powerful TYPICAL APPLICATIONS. Conveyor Rugged. Extruder Reliable. Conveyor Simple. Mixer Flexible

Fincor DC Drives. Flexible & Powerful TYPICAL APPLICATIONS. Conveyor Rugged. Extruder Reliable. Conveyor Simple. Mixer Flexible DC Drives Flexible & Powerful single-phase DC drives provide a complete family solution from the compact Series 2120 chassis drive to the powerful Series 2230 and it s feature rich application specific

More information

Security and Remote Start Installation Guide for models: ca6553 ca6553sst

Security and Remote Start Installation Guide for models: ca6553 ca6553sst PROFESSIONAL SERIES Security and Remote Start Installation Guide for models: ca6553 ca6553sst 2012 Audiovox Electronics Corporation. All rights reserved. 1 Table of Contents Before You Begin... 4 Wire

More information

RE-PR3-E-86&105 3-Phase Panel Mount 86 and 105kW

RE-PR3-E-86&105 3-Phase Panel Mount 86 and 105kW Page 1 of 6 3-Phase Panel Mount 86 and 105kW Features: Benefits: 0-10Vdc, 0-5Vdc, 4-20mA or manual via potentiometer control input Over temperature protection with auto reset Enclosed panel mounting Efficient

More information

Automatic / Manual Transmission Remote Start with Keyless Entry Installation Guide. ca 5152

Automatic / Manual Transmission Remote Start with Keyless Entry Installation Guide. ca 5152 PROFESSIONAL SERIES Automatic / Manual Transmission Remote Start with Keyless Entry Installation Guide ca 5152 1 Table of Contents Before You Begin... 3 Wire Connection Guide... 4 11 Pin Main Harness...

More information

Current Steering Module ECM0001

Current Steering Module ECM0001 Engineering & Manufacturing Solutions Current Steering Module ECM0001 ISO 9001:2008 WITH DESIGN Certificate #02.002.1 Features / Description / Specifications ECM0001Current Steering Module FEATURES: Eliminates

More information

Security and Remote Start Installation Guide for models: ca6554

Security and Remote Start Installation Guide for models: ca6554 PROFESSIONAL SERIES Security and Remote Start Installation Guide for models: ca6554 2014 Voxx Electronics Corporation. All rights reserved. 1 Table of Contents Before You Begin...4 Wire Connection Guide...5

More information

2005 Directed Electronics, Inc. Vista, CA N412V 01-05

2005 Directed Electronics, Inc. Vista, CA N412V 01-05 Model 211HV Installation Guide NOTE: This product is intended for installation by a professional installer only! Any attempt to install this product by any person other than a trained professional may

More information

UNIT 3: GENErAL ELECTriCAL SySTEM DiAGNOSiS

UNIT 3: GENErAL ELECTriCAL SySTEM DiAGNOSiS Electrical/Electronic Systems UNIT 3: GENErAL ELECTriCAL SySTEM DiAGNOSiS LESSON 3: TEST electrical circuits I. Types of electrical circuit tests and electrical faults A. Different types of electrical

More information

CA-210 Installation Instructions

CA-210 Installation Instructions CA-210 Installation Instructions PROFESSIONAL INSTALLATION STRONGLY RECOMMENDED Installation Precautions: Roll down window to avoid locking keys in vehicle during installation Avoid mounting components

More information

A6Z OPERATING MANUAL

A6Z OPERATING MANUAL A6Z OPERATING MANUAL TABLE OF CONTENTS Introduction... p. 2 Features... p. 2 Description... p. 3 Theory of Operation... p. 3 Installation... p. 4 Electrical Connections... p. 5 Options... p. 6 Warranty.p.

More information

CARM INTERNATIONAL TOWING MODULES

CARM INTERNATIONAL TOWING MODULES CARM INTERNATIONAL TOWING MODULES (TA100/200 Instructions Revision = 1) Each Towing Module (if ordered with Loom Pack) is shipped with: A/ These instructions B/ 1 x Towing Control Module C/ 1 x high current

More information

PREMIER POWER PACK INSTRUCTION MANUAL EN54-4 POWER SUPPLY UNIT INSTRUCTION MANUAL. GLT.MAN-138 Issue: /05/2016 N.R.P.J.

PREMIER POWER PACK INSTRUCTION MANUAL EN54-4 POWER SUPPLY UNIT INSTRUCTION MANUAL. GLT.MAN-138 Issue: /05/2016 N.R.P.J. EN54-4 POWER SUPPLY UNIT INSTRUCTION MANUAL GLT.MAN-138 CONTENTS Introduction to the Premier Power Pack PSU... 2 Changes to EN54-4 (The Fire Alarm Equipment Power Supply Standard)... 3 Indications... 4

More information

RAPID Environment Control INSTALLATION GUIDE. Ver 99C. RAPID Environment Control. Creep

RAPID Environment Control INSTALLATION GUIDE. Ver 99C. RAPID Environment Control. Creep RAPID Environment Control INSTALLATION GUIDE Ver 99C RAPID Environment Control 1 2 3 4 5 6 7 8 9 0 Room Ambient Creep S Y S T E M S Variable Ouput 2 Indicator Variable Ouput 1 Indicator S Y S T E M S Increase

More information

MD10. Engine Controller. Installation and User Manual for the MD10 Engine Controller. Full Version

MD10. Engine Controller. Installation and User Manual for the MD10 Engine Controller. Full Version MD10 Engine Controller Installation and User Manual for the MD10 Engine Controller. Full Version File: MartinMD10rev1.4.doc May 16, 2002 2 READ MANUAL BEFORE INSTALLING UNIT Receipt of shipment and warranty

More information

INSTALLATION MANUAL. This unit is designed for professional installation only and must be installed by an authorized Silencer dealer.

INSTALLATION MANUAL. This unit is designed for professional installation only and must be installed by an authorized Silencer dealer. INSTALLATION MANUAL SL- 3 3-Channel Security with Keyless Entry System This unit is designed for professional installation only and must be installed by an authorized Silencer dealer. For Warranty information:

More information

Max. 30A 2 Coils Normal Open Contact Type. Positive Car : Ground, or. Max. 20A 2 Coils Normal Open Contact Type. Battery. Positive Car : Ground, or

Max. 30A 2 Coils Normal Open Contact Type. Positive Car : Ground, or. Max. 20A 2 Coils Normal Open Contact Type. Battery. Positive Car : Ground, or HEAD LIGHT RELAY SLR-12B W/FUSE, RED COVER Max. 30A 2 Coils Normal Open Contact Type B Battery S1, S2 Dimmer SW or Toggle SW L1, L2 Head Lamp or Fog & Driving Lamp S3 Positive Car : Ground, or Negative

More information

LBC Series Battery Charger Instructions

LBC Series Battery Charger Instructions Ver1.2 Date: 2016/03/22 Version History Date Version Content 2014-05-19 1.0 Start Publishing 2015-03-12 1.1 Add BOOST, Charging Failure Alarm function 2016-03-22 1.2 Modify details : T:+86-769-23836636

More information

Press and release the valet switch 3 times 1 Chirp - LED 1 flash

Press and release the valet switch 3 times 1 Chirp - LED 1 flash Y Model PRO-9800 Installation Manual SELECTABLE FEATURES Note : The method of manual override can either be selected to operate from the valet switch or operate as custom code. Be certain to place a check

More information

The House of Gate Automation

The House of Gate Automation OPTIONAL EXTRA'S SOFT START / SOFT START This is provided as an optional extra and must be requested to fit to a new or old system. It provides an adjustable slow start and slow stop to prevent slambing

More information

User Guide 4Q kW D.C.Motor Regenerative Speed Controller. Part Number: Issue Number: 3

User Guide 4Q kW D.C.Motor Regenerative Speed Controller. Part Number: Issue Number: 3 User Guide 4Q2 0.55-7.5kW D.C.Motor Regenerative Speed Controller Part Number: 0400-0042-03 Issue Number: 3 General Information The manufacturer accepts no liability for any consequences resulting from

More information

4 Channel Remote Car Starter With Full Feature Alarm System Installation Instructions

4 Channel Remote Car Starter With Full Feature Alarm System Installation Instructions Model PRO-9675FT4 Installation Manual 4 Channel Remote Car Starter With Full Feature Alarm System Installation Instructions This Unit Is Intended For Installation In Vehicles With 12 Volt Negative Ground

More information

ASSEMBLY INSTRUCTIONS FOR NEW FK109 4 LED Railroad Crossing Flasher Kit WITH ADJUSTABLE FLASHING SPEED CONTROL with 4 Red 3mm Leds

ASSEMBLY INSTRUCTIONS FOR NEW FK109 4 LED Railroad Crossing Flasher Kit WITH ADJUSTABLE FLASHING SPEED CONTROL with 4 Red 3mm Leds ASSEMBLY INSTRUCTIONS FOR NEW FK109 4 LED Railroad Crossing Flasher Kit WITH ADJUSTABLE FLASHING SPEED CONTROL with 4 Red 3mm Leds Description: Very easy to build, The FK109 Led Flasher kit makes the perfect

More information