SECURITY DOOR CONTROLS

Size: px
Start display at page:

Download "SECURITY DOOR CONTROLS"

Transcription

1 CR4 FOUR STATION CONTROL MODULE The CR4 module operates on 12V or 24V DC and provides control of four (4) stations. Each CR4 station accepts a Dry () trigger input and provides one (1) Fused 2 Amp SPDT Output (jumper selectable Wet or Dry ) and one (1) Non-fused Dry (2 Amp) SPDT output. Closing a switch across the Dry Trigger Input for Station A, B, C or D will release the output for the amount of time that the trigger input is held closed. The CR4 module can be used to indicate status or implement multiple door interlocks. FUSED OUTPUTS (WET OR DRY) * NC NC N-FUSED OUTPUTS (DRY ONLY) STATION A J1 D1 J1 STATION B STATION C STATION D A1 A2 B1 B2 C1 C2 D1 D2 A3 A4 A5 A6 A7 A8 J2 B3 B4 B5 B6 B7 B8 C3 C4 C5 C6 C7 C8 D3 D4 D5 D6 D7 D8 J3 J4 D2 D3 D4 WET DRY REMOVE JUMPER(S) TO CHANGE TERMINALS 3,4 & 5 FROM A VOLTAGE OUTPUT (WET) TO A DRY CONTACT OUTPUT F1 F2 F3 F4 D5 D6 INPUT CONTROLLER 12V TO 24VDC /24 VDC Controller Dimensions: 6" x 3" x ⅞" (152mm x 77mm x 23mm) Controller Input Voltage: 12V or 24VAC or DC; 0.15 Amp Maximum Controller Stations: Four (4) Independent Stations Control Inputs (Per Station): One (1) (Dry Contact Required) Controller Outputs (Per Station): One (1) SPDT Non Fused Dry Output and One (1) SPDT Fused Wet or Dry Output (Jumper selectable Wet or Dry) Relay Contact Ratings: 2 30VDC (resistive) P:\INSTALLATION INST\Power Supplies\INST-CR4.vsd REV C 0507 Page 1 Any suggestions or comments to this instruction or product are welcome. Please contact us through our website or engineer@sdcsecurity.com

2 The SDC ACM-1 Access Control Module is an installer friendly interface relay board designed to release a magnetic locking device or electric strike, to provide a lock status output and to provide easy to use multiple wiring terminals for additional access control REX (Request to Exit) inputs. ACM-1 Operation When any REX input is activated, the relay will release the magnetic lock or electric strike. The Lock Status Output will change state and the green LED will illuminate. Compatible with any Request to Exit (REX) output, i.e. Request-to-Exit Push Bar, Keypad, Card Reader, Motion Sensor, Push Button or Key Switch. SUPPLY - + N/C N/O MONITOR OUTPUTS FAIL SAFE LOCK or ADD JUMPER FOR 12VDC OPERATION - + FAIL SECURE LOCK D3 N/C REX N/O REX ACTIVE INDICATOR ELECTRICAL DATA N/C ACCESS CONTROL TE: JUMPER ALL UNUSED N/C N/O ACCESS CONTROL 12/24vdc Input Voltage. 75mA Input controller current. 4 N/C Normally Closed Inputs with screw terminals. 4 N/O Normally Open Inputs with screw terminals. 5 Amp (Resistive) Fail Safe Lock Output. 5 Amp (Resistive) Fail Secure Lock Output. Lock Status Output SPDT (Form C) Dry Contact. Green LED Indicator Illuminated when lock is activated. Size: 3-3/8 (86mm) W x 4-1/4 (108mm) L x 3/4 (19mm) H. Fits all SDC Power Supplies. Requires 2 Module spaces. Supplied with mounting screws and standoffs for J-box mounting. P:\INSTALLATION INST\ SUPPLY\INST-ACM-1\INST-ACM-1.vsd REV A Page 1 Any suggestions or comments to this instruction or product are welcome. Please contact us through our website or engineer@sdcsecurity.com

3 FB-4 FUSED TERMINAL BOARD The FB-4 provides four (4) individually fused outputs for modular system protection. The fuse rating for each output is determined by the load current of each output. The fused voltage output is the same as the voltage input. The total current of all outputs can not exceed the power supply current rating. MODEL FB-4 M:\INS\INST-FB-4.qxd REV A 1000

4 DOOR CONTROL MODULES CR/TD C.R. CONTROL MODULE 1. Select wet or dry trigger input. 2. Wet trigger input must be same as output voltage, AC or DC. 3. N.O. trigger inputs shown. When using N.C. trigger inputs, outputs are reversed. TRIGGER WET MODE (APPLYING RELEASES LOCK) TRIGGER DRY MODE (CLOSING SWITCH RELEASES LOCK) CR Control Relay Module. 1 SPDT voltage output Max. 5 12/24VDC 1 SPDT dry contact 5 30 VAC. T.D. TIME DELAY MODULE 1. Wet and dry trigger input may be used. 2. Wet trigger input may be 12V or 24V AC or DC. 3. Normally off wet trigger input shown. When using normally on trigger input, outputs are reversed. 4. Reset; adding door position switch resets timer to assure immediate relocking when door closes to guard against unauthorized entry of following pedestrian. TD Second Adjustable time delay. 1 SPDT voltage output Max. 5 12/24VDC. 1 SPDT dry contact 5 30 VDC. M:\INS\INST-CR_TD.qxd 0599 Page 1

5 DOOR CONTROL MODULES PB-8, PB-16 BOOSTER MODULES: 1. Dry trigger input only. 2. Both outputs are fail secure. PB-8 PB-16 Power Booster for High Inrush Electric Panic Devices and Locks. 1 Amp 24 VDC, 8 Amp surge output. Power Booster for High Inrush Electric Panic Devices and Locks. 1 Amp 24 VDC, 16 Amp surge output. M:\INS\INST-PB.qxd REV A 0102 Page 1 of 1

INSTALLATION INSTRUCTIONS 410/420 SERIES PUSH SWITCH

INSTALLATION INSTRUCTIONS 410/420 SERIES PUSH SWITCH 801 Avenida Acaso, Camarillo, Ca. 93012 (805) 4940622 www.sdcsecurity.com Email: service@sdcsecurity.com 410/420 SERIES PUSH SWITCH (N/C) Contact Type: SPDT (Form C) (COM) (N/O) LAMP 28VDC MAX P:\INSTALLATION

More information

Power Supplies DORMA PS

Power Supplies DORMA PS Power Supplies DORMA PS DORMA PS Power Supplies Main System On/Off or Fire Panel Relay - The power supply output voltage can be controlled by the main system on/off control relay which accepts a closed

More information

Power Supply. & Door Controllers 238 SECURITY DOOR CONTROLS

Power Supply. & Door Controllers 238 SECURITY DOOR CONTROLS Security Door Controls & Door Controllers 5 SDC Access Control Power Supplies have been developed specifically to support access controls and electric locking hardware with clean, consistent power. Combined

More information

ARCHITECTURAL DOOR HARDWARE POWER SUPPLIES & TRANSFORMER CATALOG

ARCHITECTURAL DOOR HARDWARE POWER SUPPLIES & TRANSFORMER CATALOG ARCHITECTURAL DOOR HARDWARE POWER SUPPLIES & TRANSFORMER CATALOG January 1, 2017 v3 West Coast Office (800) 544-4422 East Coast Office (800) 225-6737 intldoorclosers.com Index POWER SUPPLIES & TRANSFORMERS

More information

SECURITY DOOR CONTROLS 801 Avenida Acaso, Camarillo, Ca (805) Fax: (805)

SECURITY DOOR CONTROLS 801 Avenida Acaso, Camarillo, Ca (805) Fax: (805) SECURITY DOOR CONTROLS 801 Avenida Acaso, Camarillo, Ca. 93012 (805) 494-0622 Fax: (805) 494-8861 www.sdcsecurity.com E-mail: service@sdcsecurity.com HI-SHEAR EMLOCKS 1565 & 1566 INSTALLATION INSTRUCTIONS

More information

INSTALLATION INSTRUCTIONS E300 SERIES MAGNETIC CABINET/DISPLAY CASE LOCK

INSTALLATION INSTRUCTIONS E300 SERIES MAGNETIC CABINET/DISPLAY CASE LOCK 801 Avenida Acaso, Camarillo, Ca. 93012 (805) 494-0622 www.sdcsecurity.com E-mail: service@sdcsecurity.com INSTALLATION INSTRUCTIONS E300 SERIES MAGNETIC CABINET/DISPLAY CASE LOCK The E300 Series magnetic

More information

INSTALLATION INSTRUCTIONS MICRO SHEAR EMLOCKS 1561 & 1562 MAX. HOLDING FORCE 2000 LBS.

INSTALLATION INSTRUCTIONS MICRO SHEAR EMLOCKS 1561 & 1562 MAX. HOLDING FORCE 2000 LBS. SECURITY DOOR CONTROLS 3580 Willow Lane, Westlake Village, CA 91361-4921 (805) 494-0622 Fax: (805) 494-8861 www.sdcsecurity.com E-mail: service@sdcsecurity.com INSTALLATION INSTRUCTIONS MICRO SHEAR EMLOCKS

More information

SmartLock Accessories

SmartLock Accessories CANSEC ACCESSORIES SmartLock Accessories CA SLbox CA SLBOX SmartLock enclosure 9.5 x 13 x 3 metal enclosure with room for 1 or 2 SmartLock controllers, Cansec power supply and 12V 7 AH battery C Ca ps123a

More information

EZ-B-10 MAGNETIC BOND SENSOR EZ-T-10 TIMER INPUT MODULE. Modular Kit. Modular Kit. EZ-D-10: DOOR POSITION SENSOR Modular Kit

EZ-B-10 MAGNETIC BOND SENSOR EZ-T-10 TIMER INPUT MODULE. Modular Kit. Modular Kit. EZ-D-10: DOOR POSITION SENSOR Modular Kit EZ Option Upgrade Kits - Emlock 1511, 1513, 1571, 1573 EMLock EZ Kits Field Upgradeable Option Modules for 1511, 1513, 1571, 1573 SDC s patented EMLock design represents the pinnacle of magnetic lock evolution.

More information

630 Series Power Supplies

630 Series Power Supplies TM 630 Series Power Supplies 631RF Series 1.5 Amp Modular Access Control Power Supply The SDC 631RF Power Supplies have been developed specifically to support electric locks and access controls. The high

More information

Accessories 286 SDC SECURITY DOOR CONTROLS

Accessories 286 SDC SECURITY DOOR CONTROLS 8 Security Door Controls From wireless remote controls to durable door holding & release devices, to REX sensors, timers, ball and magnetic switches, and from concealed contact to universal mounting enclosure

More information

LOCKNETICS Power Supplies. 510 Series Power Supply Controller 12 and 24 VDC. 505 Series Power Supply. 505DE Series Delayed Egress Controller

LOCKNETICS Power Supplies. 510 Series Power Supply Controller 12 and 24 VDC. 505 Series Power Supply. 505DE Series Delayed Egress Controller 505 Series Low voltage DC, regulated, filtered. Step down transformer, fused primary and 6 heavy duty 505 shown with SBP2 KLC screw terminals. 12 VDC - 1 Amp, 24 VDC - 1 Amp, field selectable. Battery

More information

INSTALLATION INSTRUCTIONS SHEAR LOCKING MAGNET 1561TJ MAX. HOLDING FORCE 2000 lbs.

INSTALLATION INSTRUCTIONS SHEAR LOCKING MAGNET 1561TJ MAX. HOLDING FORCE 2000 lbs. 801 Avenida Acaso, Camarillo, Ca. 93012 (805) 494-0622 www.sdcsecurity.com E-mail: service@sdcsecurity.com INSTALLATION INSTRUCTIONS SHEAR LOCKING MAGNET 1561TJ MAX. HOLDING FORCE 2000 lbs. REFER TO THE

More information

ACSI MODEL 1406BB-04-AO POWER SUPPLY INSTALLATION INSTRUCTIONS

ACSI MODEL 1406BB-04-AO POWER SUPPLY INSTALLATION INSTRUCTIONS II 1400-10 ACSI MODEL 1406BB-04-AO POWER SUPPLY INSTALLATION INSTRUCTIONS Features: Up to 1.95 Amps Load Capacity Class 2 Rated Outputs Overload, Over Voltage, and Short Circuit Protection Standby Battery

More information

INSTALLATION INSTRUCTIONS MINI EXIT CHECK DELAYED EGRESS EMLOCK 1581S

INSTALLATION INSTRUCTIONS MINI EXIT CHECK DELAYED EGRESS EMLOCK 1581S SECURITY DOOR CONTROLS 3580 Willow Lane, Westlake Village, CA 91361-4921 (805) 494-0622 Fax: (805) 494-8861 www.sdcsecurity.com E-mail: service@sdcsecurity.com INSTALLATION INSTRUCTIONS MINI EXIT CHECK

More information

ARCHITECTURAL CONTROL SYSTEMS, INCORPORATED ST. LOUIS, MISSOURI

ARCHITECTURAL CONTROL SYSTEMS, INCORPORATED ST. LOUIS, MISSOURI II 1400-6 ARCHITECTURAL CONTROL SYSTEMS, INCORPORATED ST. LOUIS, MISSOURI ACSI 1426-04-AO ELECTRIC LATCH RETRACTION CONTROLLER INSTALLATION INSTRUCTIONS I.D. 1092, REV. C INSTALLATION For C-UL Listed applications,

More information

5000 SERIES POWER SUPPLY/CHARGERS INSTALLATION GUIDE

5000 SERIES POWER SUPPLY/CHARGERS INSTALLATION GUIDE 5000 SERIES POWER SUPPLY/CHARGERS INSTALLATION GUIDE MODEL# 505 ( AMP @ VDC OR 4VDC) MODEL# 5500 ( AMP @ VDC OR AMPS @ 4VDC) MODEL# 5600- (0 AMPS @ VDC) MODEL# 5600-4 (5 AMPS @ 4VDC) IMPORTANT SAFETY INSTRUCTIONS

More information

SAFETY

SAFETY 24 SAFETY SECURITY ELECTROMAGNETS IDEAL FOR EMERGENCY EXITS AND CONDOMINIUM ENTRY DOORS SILENT AND RESISTANT HOLDING FORCE FROM 150 TO 1500 KG CAN BE APPLIED ON PRE-EXISTING DOORS 25 26 SAFETY www.opera-italy.com

More information

cel SECURITY DOOR CONTROLS Value Engineered Access Hardware sdcsecurity.com Power Supplies Exit Switches

cel SECURITY DOOR CONTROLS Value Engineered Access Hardware sdcsecurity.com Power Supplies Exit Switches Security Door Controls cel TM Value Engineered Access Hardware Excel E1200 Excel E600 Excel E300 Excel Series Value Engineered Access Hardware from SDC Economically Priced Alternative to Low Cost Imports

More information

ACSI MODEL 1440 POWER SUPPLY INSTALLATION INSTRUCTIONS

ACSI MODEL 1440 POWER SUPPLY INSTALLATION INSTRUCTIONS II 1400-8 Features: ACSI MODEL 1440 POWER SUPPLY INSTALLATION INSTRUCTIONS Filtered/Regulated 24 Volts DC Up to Full 2 Amps Load Capacity Class 2 Rated Outputs Overload, Over Voltage, and Short Circuit

More information

CB-9 CONTROL BOARD INSTRUCTION MANUAL

CB-9 CONTROL BOARD INSTRUCTION MANUAL CB-9 CONTROL BOARD INSTRUCTION MANUAL AUGUST 95 The CB-9 control board is designed to automate 1 or 2 A.T.A swing gate or sliding gate drive units. This instruction manual gives detailed instructions on

More information

CX-EMF-2 MULTI-FUNCTION RELAY

CX-EMF-2 MULTI-FUNCTION RELAY ELECTRIFIED S, RELAYS & TIMERS RELAYS & TIMERS ABM MULTI-FUNCTION RELAY FEATURES MICROPROCESSOR CONTROL USER SELECTABLE MULTI-APPLICATION DESIGN PLUG-IN CONNECRS FOR WIRING ACCEPTS UP 7 DRY INPUTS DESCRIPTION

More information

ACCESS & EGRESS POWER SUPPLY & DOOR CONTROLS SOLUTIONS. The lock behind the system. SDCSecurity.com

ACCESS & EGRESS POWER SUPPLY & DOOR CONTROLS SOLUTIONS. The lock behind the system. SDCSecurity.com ACCESS & EGRESS SOLUTIONS POWER SUPPLY & DOOR CONTROLS 6 2 7 3 4 1 2 The lock behind the system SDCSecurity.com 800.413.8783 service@sdcsecurity.com Complete Component Considerations 7 3 6 AC Mains 1 Locking

More information

ELECTROMAGNETIC LOCKS

ELECTROMAGNETIC LOCKS safety 17 18 SAFETY ELECTROMAGNETIC LOCKS 12500 Electromagnetic lock Micro series Version: for mortice fixing body in stainless steel protected against humidity Dimensions of the body (mm): 170 x 32 x

More information

MANUAL ELECTRIC FIRE PUMP CONTROLLERS METRON SERIES MV600

MANUAL ELECTRIC FIRE PUMP CONTROLLERS METRON SERIES MV600 MANUAL ELECTRIC FIRE PUMP CONTROLLERS METRON SERIES MV600 TABLE OF CONTENTS PART I GENERAL DESCRIPTION... PAGE 2 PART II FUNCTIONS... PAGE 2 PART III INSTALLATION... PAGE 3 PART IV INITIAL INSTALLATION

More information

AccuPower AQU126B Installation Instructions

AccuPower AQU126B Installation Instructions Tel 1.800.MAGLOCK info@securitron.com 1.800.624.5625 www.securitron.com AccuPower AQU126B Installation Instructions Recommended Tools & Additional Materials #2 Phillips Screw Driver Wire connectors Lead

More information

2904 Power Supply Installation Instructions I-EA00041

2904 Power Supply Installation Instructions I-EA00041 FEATURES Controls an opening with electrified locking device and automatic door operator Separate inputs for activation switch on entry and exit sides of opening Separate 24 VDC outputs for fail safe and

More information

EMLock 1500 Series. MEA Listed

EMLock 1500 Series. MEA Listed EMLock 1500 Series SDC s patented EMLock design represents the pinnacle of magnetic lock evolution. The modular EMLock assembly makes them easy to stock, install, upgrade and maintain. Patented SDC 1500

More information

CB CONTROL BOARD INSTRUCTION MANUAL VERSION 1.03 DATE 30/10/2000

CB CONTROL BOARD INSTRUCTION MANUAL VERSION 1.03 DATE 30/10/2000 CB-9 3.02 CONTROL BOARD INSTRUCTION MANUAL VERSION 1.03 DATE 30/10/2000 FIRMWARE VERSION 1.09 Thank you for choosing the CB-9 control system. We encourage you to read and understand this manual prior to

More information

56- Electric Latch Retraction Exit Devices Installation and Wiring Instructions

56- Electric Latch Retraction Exit Devices Installation and Wiring Instructions SECTION I: OVERVIEW 1. Description The Sargent 56- prefix ELR works with 80 Series exit devices to provide remote-controlled latch retraction. It is compatible with the following prefixes: 53 - Latchbolt

More information

S6100 SERIES REVERSIBLE PANIC/FIRE EXIT RIM DEVICES INSTALLATION INSTRUCTIONS

S6100 SERIES REVERSIBLE PANIC/FIRE EXIT RIM DEVICES INSTALLATION INSTRUCTIONS 801 Avenida Acaso, Camarillo, Ca. 93012 (805) 494-0622 www.sdcsecurity.com E-mail: service@sdcsecurity.com S6100 SERIES REVERSIBLE PANIC/FIRE EXIT RIM DEVICES INSTALLATION INSTRUCTIONS These instructions

More information

Addendum. SL3000ULE series. to the SL3000UL series owners manual. manually push vehicular gate open for emergencies

Addendum. SL3000ULE series. to the SL3000UL series owners manual. manually push vehicular gate open for emergencies Addendum to the SL3000UL series owners manual Release Date 07/05 SL3000ULE series manually push vehicular gate open for emergencies Manual Backdrive 01-51245B For technical support: 1-800-528-2806 2005

More information

AccuPower AQU128B Installation Instructions

AccuPower AQU128B Installation Instructions Tel 1.800.MAGLOCK info@securitron.com 1.800.624.5625 www.securitron.com AccuPower AQU128B Installation Instructions Recommended Tools & Additional Materials #2 Phillips Screw Driver Wire connectors Lead

More information

Excel Series Value Engineered Access Hardware

Excel Series Value Engineered Access Hardware Excel Series Value Engineered Access Hardware Excel E1200 Economically Priced Alternative to Low Cost Imports Quality and Flexibility for Commercial Applications. The Excel product line is designed for

More information

INSTALLATION INSTRUCTIONS DEGR7700 DELAYED EGRESS ALL IN ONE DEVICE

INSTALLATION INSTRUCTIONS DEGR7700 DELAYED EGRESS ALL IN ONE DEVICE INSTALLATI INSTRUCTIS DEGR7700 DELAYED EGRESS ALL IN E DEVICE Stop Employee Theft Stop Retail Shoplifting Restrict Airport Patrons Restrict Wandering Patients SOUNDS. DOOR CAN BE The sign provides comprehensive

More information

Offers Premium Security

Offers Premium Security SAFLOK TM Offers Premium Security MT trim In today s challenging world, having a building that is safe and secure is essential. SAFLOK TM, a global leader in developing and manufacturing state-of-the-art

More information

INSTALLATION INSTRUCTIONS 1576DE DELAYED EGRESS EMLOCK

INSTALLATION INSTRUCTIONS 1576DE DELAYED EGRESS EMLOCK 801 Avenida Acaso, Camarillo, Ca. 930 (805) 494-0622 www.sdcsecurity.com E-mail: service@sdcsecurity.com INSTALLATION INSTRUCTIONS 1576DE DELAYED EGRESS EMLOCK PUSH UNTIL ALARM SOUNDS. DOOR CAN BE OPENED

More information

Electrified Products TABLE OF CONTENTS. P Power Supply Power Transfers Pressure Sense Bars Proximity Cards & Keys...

Electrified Products TABLE OF CONTENTS. P Power Supply Power Transfers Pressure Sense Bars Proximity Cards & Keys... TABLE OF CONTENTS A Adjustable Angle Bracket (2941/2942)... 6 Angle Brackets (2950 Series)... 9 Armature Mounting Plates (2950 Series)...7-8 C Coordinator Mounting Bracket (2950 Series)... 8 Concealed

More information

Electrified Products TABLE OF CONTENTS. P Power Supply Power Transfers Pressure Sense Bars Proximity Cards & Keys...

Electrified Products TABLE OF CONTENTS. P Power Supply Power Transfers Pressure Sense Bars Proximity Cards & Keys... TABLE OF CONTENTS A Adjustable Angle Bracket (2941/2942)... 6 Angle Brackets (2950 Series)... 9 Armature Mounting Plates (2950 Series)...7-8 C Coordinator Mounting Bracket (2950 Series)... 8 Concealed

More information

Operations Manual. Zero Speed Switch Sensor Model ZS09P

Operations Manual. Zero Speed Switch Sensor Model ZS09P Zero Speed Switch Sensor Model ZS09P The must be referred to for correct installation. Failure to comply with the shall void all warranties and liabilities. Overview The Phares Electronics Model ZS09P

More information

Security alarms, warning systems.

Security alarms, warning systems. SIREN DRIVER BOARD. Free running siren activated by the application of a V DC power source. This module is capable of driving a maximum of 2 x 8 ohm 10W speakers and produces approximately 110 db at one

More information

60 Series Engine Controls

60 Series Engine Controls ECU 60 Series Engine Controls Use CAUTION since you are applying 120VAC RMS to the AC Input terminals and that it is always potentially their during engine run!!! ECU is a registered trademark of Engineering

More information

Senior Swing Control Box. Table of Contents

Senior Swing Control Box. Table of Contents *740100* 740100 2800 Overhead Consealed Series 9500 Surface Applied Series Senior Swing Control Box Installation Instructions important These instructions are presented in step-by-step sequence. It is

More information

Electric Dropbolts. Secure and Intelligent Bolts. Fail-Safe Series Functions. DPS & BSS Outputs. Fail-Secure Series Functions

Electric Dropbolts. Secure and Intelligent Bolts. Fail-Safe Series Functions. DPS & BSS Outputs. Fail-Secure Series Functions Secure and Intelligent Bolts are mortise mounted and available in fail-safe and fail-secure mode. The Electric Dropbolt Fail-safe series electric dropbolts can be mounted horizontally or vertically and

More information

LCN AUTOMATIC OPERATORS

LCN AUTOMATIC OPERATORS LCN AUTOMATIC OPERATORS SENIOR 9530 SENIOR 9540 SENIOR 9550 SENIOR 9560 8310 ACCESSORIES LCN ELECTROMECHANICAL POWERED SYSTEMS ELECTROMECHANICAL AUTOMATIC OPERATORS LCN s electromechanical products are

More information

GLM SERIES CONTROL Users Manual Rev:

GLM SERIES CONTROL Users Manual Rev: GLM SERIES CONTROL Users Manual Rev: 808062 Connecting Power Page 2 Motor Terminal Wiring Diagrams Page 3 Getting Started / Setup Page 4 1. Obstruction Detection Devices Page 4 2. Checking Power and Direction

More information

Requirements LEO Power Operator Installation Instructions Patents: 5,881,497; 7,316,096; 7,484,333 CAUTION CAUTION WARNING

Requirements LEO Power Operator Installation Instructions Patents: 5,881,497; 7,316,096; 7,484,333 CAUTION CAUTION WARNING CAUTION 80-957-00-00 (08-0) Series 570 Openings 85 to 0 or to 70 Double Lever Arm Application for Frame Reveals (76) to 7 (78mm)* Stop (Push) Side of Installation 5700 LEO Operator Installation Instructions

More information

Requirements LEO Power Operator Installation Instructions Patents: 5,881,497; 7,316,096; 7,484,333 CAUTION CAUTION WARNING

Requirements LEO Power Operator Installation Instructions Patents: 5,881,497; 7,316,096; 7,484,333 CAUTION CAUTION WARNING CAUTION 80-957-00-00 (08-0) Series 570 Door Openings 85 to 0 or to 80 Adjustable Arm and Slide Track Application Maximum Hinge Side Frame Reveal to /8 (mm) Hinge (Pull) Side of Door Installation 5700 LEO

More information

ASSA ABLOY Series Power Operator Installation and Instruction ASSA Manual ABLOY ASSA ABLOY

ASSA ABLOY Series Power Operator Installation and Instruction ASSA Manual ABLOY ASSA ABLOY 0 Series Power Operator Installation and Instruction ASSA Manual ABLOY Item No. Description Motor (00M) Cover (00COV) Control Inverter (00IN) Power Supply VDC (00PS) / Replacement Motor Key (00KEY) Rod

More information

INSTALLATION MANUAL. Model: PLUS For Technical Assistance, please call (800) , or visit

INSTALLATION MANUAL. Model: PLUS For Technical Assistance, please call (800) , or visit R Vehicle Security INSTALLATION MANUAL Model: PLUS-4700 This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference;

More information

91 (2311 mm) (1581mm) (1375 mm)

91 (2311 mm) (1581mm) (1375 mm) ALVARADO MSTX Maximum Security Turnstile Technical Specifications Dimensions Unit Height: Unit Width: Unit Depth: 91 (2311 mm) 62.25 (1581mm) 54.125 (1375 mm) Materials Yoke: (Curved Section) Yoke Guard

More information

Visit our web site at AMR LS-3000, LS-3010 & LS-3020 BELT SLIP/SEQUENCE CONTROL INSTALLATION AND SETUP INSTRUCTIONS

Visit our web site at   AMR LS-3000, LS-3010 & LS-3020 BELT SLIP/SEQUENCE CONTROL INSTALLATION AND SETUP INSTRUCTIONS AMR INC. DESIGN & MANUFACTURING FOR MINING WORLDWIDE P.O. BOX 234, ROCKY GAP, VA 24366 PHONE (276)928-1712 FAX (276)928-1814 Email sales@americanmineresearch.com Visit our web site at www.americanmineresearch.com

More information

Applications: Three-phase DC drive for regenerative and non-regenerative industrial applications from 1-1/2 to 600 Hp

Applications: Three-phase DC drive for regenerative and non-regenerative industrial applications from 1-1/2 to 600 Hp FlexPak 3000 Digital DC Drives DC & Controls Applications: Three-phase DC drive for regenerative and non-regenerative industrial applications from 1-1/2 to 600 Hp HVAC Features: Flexible design allows

More information

User Manual. T6 Tachometer. Online: Telephone: P.O. Box St. Petersburg, Florida 33736

User Manual. T6 Tachometer. Online:   Telephone: P.O. Box St. Petersburg, Florida 33736 User Manual T6 Tachometer Online: www.phareselectronics.com Telephone: 727-623-0894 P.O. Box 67251 St. Petersburg, Florida 33736 Table of Contents Overview... 1 Description... 1 Wiring... 1 T6 Tachometer

More information

Flight Systems. Replacement for KASSEC DESCRIPTION

Flight Systems.   Replacement for KASSEC DESCRIPTION DESCRIPTION The is a universal generator controller that will start, stop, and provide engine protection for most generators. Universal replacement for both the 90353 and 90354 KASSEC Compatible with most

More information

ALVARADO (1029 mm) 25 (635 mm) 36.5 (927.1 mm)

ALVARADO (1029 mm) 25 (635 mm) 36.5 (927.1 mm) ALVARADO EDCX Bullnose Waist High Turnstile Technical Specifications Dimensions Unit Height: Unit Width: Unit Depth: 40.5 (1029 mm) 25 (635 mm) 36.5 (927.1 mm) Materials Cabinet: Formed and welded 14 gauge

More information

ASSA ABLOY Series Power Operator Installation and Instruction ASSA Manual ABLOY ASSA ABLOY

ASSA ABLOY Series Power Operator Installation and Instruction ASSA Manual ABLOY ASSA ABLOY 00 Series Power Operator Installation and Instruction ASSA Manual ABLOY Item No. Description Motor (00M) Cover (00COV) Control Inverter (00IN) Power Supply VDC (00PS) Track Assembly (0-) / Replacement

More information

ASSEMBLING THE 15 INCH FLUSH MOUNT TOUCH SCREEN DIMENSIONS OF THE 15 INCH FLUSH MOUNT TOUCH SCREEN

ASSEMBLING THE 15 INCH FLUSH MOUNT TOUCH SCREEN DIMENSIONS OF THE 15 INCH FLUSH MOUNT TOUCH SCREEN DIMENSIONS OF THE 15 INCH FLUSH MOUNT TOUCH SCREEN 18 (457 mm) 12 39/64 (320 mm) 3 1/2 (89 mm) 1 13/32 (36 mm) 19 (483 mm) 3 5/8 (92 mm) 7/64 3 mm) 1 13/32 (36 mm) 23 53/64 (605 mm) 20 3/4 (527 mm) 12

More information

VERTICAL SECURITY SOLENOID LOCKS

VERTICAL SECURITY SOLENOID LOCKS PRIMA 77 78 PRIMA VERTICAL SECURITY SOLENOID LOCKS 24600 Solenoid bolt for interlocking systems Mechanical opening with European type cylinder (cylinder with internal Armature plate in stainless steel

More information

(1032 mm) 30.5 (775 mm) 44 ( mm)

(1032 mm) 30.5 (775 mm) 44 ( mm) ALVARADO EDCX-EK Waist High Turnstile Technical Specifications Dimensions Unit Height: Unit Width: Unit Depth: 40.625 (1032 mm) 30.5 (775 mm) 44 (1117.6 mm) Materials Cabinet: Formed and welded 14 gauge

More information

2 & 3 Door Siphon Installation Instructions

2 & 3 Door Siphon Installation Instructions & Door Siphon Installation Instructions Door Siphon System System Facilities Only one door to be released electrically at any one time. A door controller at each door (up to eight doors) to facilitate

More information

Aftermarket Interface Module

Aftermarket Interface Module An ISO 9001:2008 Registered Company Aftermarket Interface Module (2015-2018 Ford Transit) AIM514-B High Side Solenoid type Coolant Valve Control AIM515-B Motor Reversing type Coolant Valve Control Introduction

More information

INQUIRY: HYROBOTICS CORP SAM LEE ( ) 5988 MID RIVER MALL DR. ST.CHARLES MO TEL : FAX :

INQUIRY: HYROBOTICS CORP SAM LEE (   ) 5988 MID RIVER MALL DR. ST.CHARLES MO TEL : FAX : INQUIRY: HYROBOTICS CORP SAM LEE ( Email : hanrobotic@msn.com ) 5988 MID RIVER MALL DR. ST.CHARLES MO 63304 TEL : 1-636-578-6059 FAX : 1-866-232-5594 1. Picker Body Installation 1-1. Picker Assembly. (Step

More information

Installation, Operation and Maintenance Manual

Installation, Operation and Maintenance Manual Document 473681 Vari-Green Motor and Controls Installation, Operation and Maintenance Manual Please read and save these instructions for future reference. Read carefully before attempting to assemble,

More information

Installation, Operation and Maintenance Manual

Installation, Operation and Maintenance Manual Document 47681 Vari-Green Motor and Controls Installation, Operation and Maintenance Manual Please read and save these instructions for future reference. Read carefully before attempting to assemble, install,

More information

Package Contents. Mounting Hardware

Package Contents. Mounting Hardware Securitron Magnalock Corp. www.securitron.com Tel 800.624.5625 techsupport@securitron.com M680BDCX MAGNALOCK SERIES Installation Instructions Table of Contents Specifications 2 Configuring Options 3 Installation

More information

Installation Instructions

Installation Instructions AQU244 & AQU128 Series Installation Instructions Installation Instructions AQU244 24vdc 5A Supervised Power Supply/Charger module AQU128 12vdc 10A Supervised Power Supply/Charger module Both Mounted in

More information

EMF-2 / EMF-2m Multi-Function Timer

EMF-2 / EMF-2m Multi-Function Timer 0 Timberlea Blvd., Mississauga, LW T Telephone: 0-- Fax: 0-- Toll-Free: --- Web: www.camdencontrols.com EMF- / EMF-m Multi-Function Timer Installation Instructions Ver. A-00 MADE IN ANADA PAGE OF Section

More information

MODEL 600LB 600 POUND SINGLE MAGNETIC LOCK WITH LED, BOND SENSOR & DOOR STATUS SENSOR SPECIFICATIONS

MODEL 600LB 600 POUND SINGLE MAGNETIC LOCK WITH LED, BOND SENSOR & DOOR STATUS SENSOR SPECIFICATIONS MODEL 600LB 600 POUND SINGLE MAGNETIC LOCK WITH LED, BOND SENSOR & STATUS SENSOR SPECIFICATIONS U.L. LISTED, LISTING NUMBER R16759 600 POUND MINIMUM HOLDING FORCE MAGNET SIZE 9-7/8 L x 1-11/16 H x1 W SIZE

More information

ELECTROMAGNETIC LOCKS

ELECTROMAGNETIC LOCKS Ahlra offers a complete range of access control devices and accessories, including electromagnetic locks, electric drop bolt, Wireless Electric Drop bolt, electric strikes, shear locks, electromechanical

More information

280+ SHEARLOCK INSTALLATION AND WIRING MODELS: 280+ and 280+TRD TRD

280+ SHEARLOCK INSTALLATION AND WIRING MODELS: 280+ and 280+TRD TRD INSTALLATION AND WIRING MODELS: 280+ and 280+TRD 280+ Standard model is a concealed electromagnetic shear lock designed to fit standard hollow metal doors and frames. In cases where the top of the door

More information

Timer Relays - Fixed & Adjustable

Timer Relays - Fixed & Adjustable Solid State Solid State relays are suitable across all applications where reliability is paramount. Unlike conventional relays, Solid State relays use electronics in place of traditional contacts, allowing

More information

7281-EA/ET INSTRUCTIONS

7281-EA/ET INSTRUCTIONS 7281-EA/ET INSTRUCTIONS The 7281 series uses the 4505 processor controlled timer module a highly accurate 30 second fixed timer or by removing a jumper, may be adjusted to provide endlessly variable time

More information

6R / 5-BUTTON SERIES VEHICLE SECURITY SYSTEM

6R / 5-BUTTON SERIES VEHICLE SECURITY SYSTEM 6R / 5-BUTTON SERIES VEHICLE SECURITY SYSTEM Button 1 Button 2 Button 5 Button 3 Button 4 Standard Features: Two 5-Button Remote Transmitters Status indicator (LED) Valet / override switch Multi-tone siren

More information

RVS-DN Digital Reduced Voltage Motor Starter

RVS-DN Digital Reduced Voltage Motor Starter RVS-DN Digital Reduced Voltage Motor Starter Specification Guide Specification Guide Contents 1.0 Introduction 2.0 Specifications 2.1 Standard Performance Features 2.2 Standard Protection Features 2.3

More information

FOR CLASS I, II, III, IV VEHICULAR GATE OPERATORS

FOR CLASS I, II, III, IV VEHICULAR GATE OPERATORS R_Ramset_Ram3000.qxd 8/19/05 4:56 PM Page 1 FOR CLASS I, II, III, IV VEHICULAR GATE OPERATORS R_Ramset_Ram3000.qxd 8/19/05 4:56 PM Page 2 www.ramsetinc.com R_Ramset_Ram3000.qxd 8/19/05 4:56 PM Page 3 TABLE

More information

Continuing Education Course #206 Introduction to Designing Machine Control Systems Part 2

Continuing Education Course #206 Introduction to Designing Machine Control Systems Part 2 1 of 5 Continuing Education Course #206 Introduction to Designing Machine Control Systems Part 2 1. Continuing to answer the following questions indicates that you understands that the presented material

More information

Installation, Operation and Maintenance Manual

Installation, Operation and Maintenance Manual Document 473681 Vari-Green Motor and Controls Installation, Operation and Maintenance Manual Please read and save these instructions for future reference. Read carefully before attempting to assemble,

More information

Installation Instructions

Installation Instructions F20/F25 Installation Instructions PROFESSIONAL INSTALLATION STRONGLY RECOMMENDED Installation Precautions: Roll down window to avoid locking keys in vehicle during installation Avoid mounting components

More information

MST. Full Height Turnstiles. alvaradomfg.com

MST. Full Height Turnstiles. alvaradomfg.com Full Height Turnstiles alvaradomfg.com The is the most trusted, secure and reliable full height turnstile available. It is installed in thousands of locations around the world and offers key product features

More information

HYPPOETL HYPPO DUALETL 12 VOLT DC Swing Gate Operator

HYPPOETL HYPPO DUALETL 12 VOLT DC Swing Gate Operator HYPPOETL HYPPO DUALETL 12 VOLT DC Swing Gate Operator Manufactured by NICE SpA INSTALLATION MANUAL 08/10 CONTENTS IMPORTANT SAFETY INSTRUCTIONS... 3 Applications...... 4 Pre-Installation Checklist... 5

More information

FOR CLASS I VEHICULAR GATE OPERATORS

FOR CLASS I VEHICULAR GATE OPERATORS FOR CLASS I VEHICULAR GATE OPERATORS www.ramsetinc.com TABLE OF CONTENTS Important Safety Requirements & Instructions.... 1 Responsibilities of Installers and Technicians. 2 Important Safety Requirements

More information

MCD Pump Application Module

MCD Pump Application Module Overview The Pump Application Module expands the soft starter's input and output functionality and is ideal for applications where greater control and feedback are required. The module provides three digital

More information

Electric Actuator Accessories. Timer Board 115 VAC Input Suffix A (For EVR, EVS & EVT actuators)

Electric Actuator Accessories. Timer Board 115 VAC Input Suffix A (For EVR, EVS & EVT actuators) Timer Board Suffix A Timer board installs within actuator enclosure. Board shown is for EVR, EVS, and EVT actuators. Cycle Time Rate Regulator Suffix B Cycle time rate regulator installs within actuator

More information

POWER PINNER RAPID FIRE 7005 RF OPERATOR S MANUAL

POWER PINNER RAPID FIRE 7005 RF OPERATOR S MANUAL POWER PINNER RAPID FIRE 7005 RF OPERATOR S MANUAL Copyright: February 20, 2007 Revised: 12-11-2015. Gripnail Corporation An Employee Owned Company 97 Dexter Road East Providence, Rhode Island 02914-2045

More information

PRIMA

PRIMA 132 PRIMA SECURITY SOLENOID LOCKS ANTI CUTTING AND ANTI BREAKING AND ENTERING REVOLVING BOLT MANUAL ACTIVATION WITH EUROPEAN CYLINDER AND HANDLE FOR AN INTENSIVE AND CONTINOUS USE IDEAL FOR STEEL OR ALUMINIUM

More information

CS-865RKE Series II REMOTE KEYLESS ENTRY SYSTEM

CS-865RKE Series II REMOTE KEYLESS ENTRY SYSTEM INTRODUCTION: CS-865RKE Series II REMOTE KEYLESS ENTRY SYSTEM INSTALLATION & OPERATING INSTRUCTIONS CONGRATULATIONS on your choice of a Remote Keyless Entry System by Crimestopper Security Products Inc.

More information

Setup and Programming Manual

Setup and Programming Manual Microprocessor and Handy Terminal Setup and Programming Manual Versions U04 to U19 for Sliding Door Systems P/N 159000 Rev 7-2-07 The manufacturer, NABCO Entrances, Inc. suggests that this manual be given

More information

HANDLING MECHANICAL INSTALLATION

HANDLING MECHANICAL INSTALLATION 2 INSTALLATION DESCRIPTION The and 2 Delay Egress Systems are 1500 pound holding force (holding force not evaluated by UL) per leaf electromagnetic locks, electronically controlled to provide a 15 or 30

More information

EMLock Magnetic Locks

EMLock Magnetic Locks EMLock EMLock Lifetime Warranty NSI/HM 156.23 Grade 1 CSFM 3774-0324:100 ME City of New York 768-80-S GWXT uxiliary Locks CVXJ urglary Resistant Electrically Operated Door Lock UL10C Positive Pressure

More information

Vertical Housing EMLock Discount Code GK LIST. Retrofit Kit for Discontinued Locknetics 390+ PLUS

Vertical Housing EMLock Discount Code GK LIST. Retrofit Kit for Discontinued Locknetics 390+ PLUS EMLock Vertical Housing EMLock LIST Vertical Housings - Side jamb mount, aprovides 2,400 or 3,300 lbs. of holding force. 1572VV82 Vertical Housing for 1572 EMLock, 8 length, for 84" opening - INCLUDES

More information

FM SECURITY AND REMOTE START SYSTEM

FM SECURITY AND REMOTE START SYSTEM FM SECURITY AND REMOTE START SYSTEM INSTALLATION MANUAL BEFORE INSTALLING THIS PRODUCT PLEASE READ THIS INSTALLATION MANUAL THOROUGHLY!! This system is intended for installation on vehicles equipped with

More information

Safety Control HR1S-AC. Safety Relay HR1S-AC

Safety Control HR1S-AC. Safety Relay HR1S-AC HRS-AC Safety Relay HRS-AC Key features: NC or 2NC safety input type, such as E-Stops or Interlock Switches EN ISO 3849- PLe, Safety Cat 3 compliant, and EN 6206 SIL 3 Fault diagnosis function with dual

More information

MODEL 1200LB 1200 POUND MAGNETIC LOCK WITH LED, BOND SENSOR & DOOR STATUS SENSOR

MODEL 1200LB 1200 POUND MAGNETIC LOCK WITH LED, BOND SENSOR & DOOR STATUS SENSOR MODEL 1200LB 1200 POUND IC LOCK WITH LED, BOND SENSOR & STATUS SENSOR U.L. LISTED, LISTING NUMBER R16756 1200 POUND MINIMUM HOLDING FORCE SIZE: 10-1/2 L x 2-7/8 H x 1-1/2 W SIZE: 7-3/8 L x 2-3/8 W x 9/16

More information

Electrohydraulic Powered Systems

Electrohydraulic Powered Systems Electrohydraulic Powered Systems ELECTRIC AUTO EQUALIZERS These Auto Equalizer products are an addition to the original pneumatic drive system. People moving through a door can use it as a normal rack

More information

PROFESSIONAL INSTALLATION STRONGLY RECOMMENDED

PROFESSIONAL INSTALLATION STRONGLY RECOMMENDED Installation Instructions CPL Master Module PROFESSIONAL INSTALLATION STRONGLY RECOMMENDED Installation Precautions: Roll down window to avoid locking keys in vehicle during installation Avoid mounting

More information

MM1 Installation Instructions

MM1 Installation Instructions MM1 Installation Instructions PROFESSIONAL INSTALLATION STRONGLY RECOMMENDED Installation Precautions: Roll down window to avoid locking keys in vehicle during installation Avoid mounting components or

More information

Typical applications are the control of barriers/booms in the parking and access control environments.

Typical applications are the control of barriers/booms in the parking and access control environments. Barrier Logic Model - BL110B The BL110B is a barrier logic unit which has been developed to control barriers using magnetic motors with ease of installation. The BL110B accepts inputs from card readers

More information

Motorized Electric Latch Retraction

Motorized Electric Latch Retraction ; SECTION I: OVERVIEW 1. Description The Corbin Russwin MELR Electric Latch Retraction (ELR), refer to Figure 1, works with ED4000 & ED5000 Series exit devices to provide remote-controlled latch retraction

More information

3200NT Timer Service Manual

3200NT Timer Service Manual Service Manual Valve Serial Number Valve Position 1-LEAd 2-LAg 3-LAg 4-LAg IMPORTANT: Fill in pertinent information on page 3 for future reference. Table of Contents Job Specifications Sheet.....................................................................

More information