Catalogue

Size: px
Start display at page:

Download "Catalogue"

Transcription

1 Catalogue Innovative system technology for modern heating, solar thermal systems & domestic hot water technology Valid for the UK

2

3 Catalogue Innovative system technology for modern heating, solar thermal systems & domestic hot water technology Valid for the UK

4 PAW heating technology Contents DN 32 DN 25 DN 20 Information Information About the company 6-7 Catalogue information 8-9 PAW heating technology - Dimensioning Mounting examples Catalogue information on the hydraulic balancing PAW MCom app 23 PAW Service app 36 Modular systems Item Short name Page DN 20 standard series Product rangeheatbloc - DN HeatBloC direct and equipment K HeatBloC with 3-way mixing valve and equipment K Controlled circuit with constant value and equipment K HeatBloC with 3-way mixing valve with bypass and equipment K Boiler charging set K Modular distribution system Thermax Thermax Modular distribution manifold and equipment MV2 - MV Hydraulic separator and equipment MVW Mounting equipment DN 25 MC series Product range HeatBloC MC - DN HeatBloC MC direct and equipment MC41 64 HeatBloC MC with 3-way mixing valve and equipment MC42 65 Controlled circuit with constant value MC and equipment MC43 66 HeatBloC MC with 3-way mixing valve with bypass and equipment MC44 67 HeatBloC MC with 3-temperature mixing valve and equipment MC45 68 Boiler charging set MC with 3-way mixing valve and equipment MC46 69 Modular distribution manifold and equipment MV2 - MV DN 25 standard series Product rangeheatbloc - DN HeatBloC direct and equipment K HeatBloC with 3-way mixing valve and equipment K Controlled circuit with constant value and equipment K Controlled circuit with constant value K33MAX HeatBloC with 3-way mixing valve with bypass and equipment K HeatBloC with 3-temperature mixing valve and equipment K Boiler charging set and equipment K36E HeatBloC with 4-way mixing valve and equipment K Extension set MCom System separation Modular distribution manifold and equipment MV2 - MV Hydraulic separator and equipment MVW Mounting equipment DN 32 MC series Product range HeatBloC MC - DN HeatBloC MC direct and equipment MC HeatBloC MC with 3-way mixing valve and equipment MC Controlled circuit MC with constant value and equipment MC HeatBloC MC with 3-way mixing valve with bypass and equipment MC Boiler charging set MC with 3-way mixing valve and equipment MC Modular distribution manifold and equipment MV2 - MV DN 32 standard series Product rangeheatbloc - DN HeatBloC direct and equipment K HeatBloC with 3-way mixing valve and equipment K HeatBloC with 3-way mixing valve with bypass and equipment K Boiler charging set and equipment K36E HeatBloC with 4-way mixing valve and equipment K Extension set MCom Modular distribution manifold and equipment MV2 - MV Hydraulic separator and equipment MVW Mounting equipment Page 4 01/2017 Printed in Germany PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu

5 PAW heating technology Contents Modular systems Item Short name Page DN 40/50 MC series Product rangeheatbloc MC DN 40/ HeatBloC MC DN 40 direct and equipment MC HeatBloC MC DN 40 with 3-way mixing valve and equipment MC Modular distribution manifolddn 40 MV2 - MV4 150 HeatBloC MC DN 50 direct and equipment MC HeatBloC MC DN 50 with 3-way mixing valve and equipment MC Modular distribution manifolddn 50 MV2 - MV4 154 DN 40/50 standard series Product rangeheatbloc DN 40/ Return flow temperature maintenance HeatBloC DN 40 direct K HeatBloC DN 40 with 3-way mixing valve K Modular distribution manifolddn 40 MV2 - MV4 150 Mounting equipment DN HeatBloC DN 50 direct K HeatBloC DN 50 with 3-way mixing valve K Modular distribution manifolddn 50 MV2 - MV4 154 Mounting equipment DN Return flow temperature maintenance with thermal control valve Return flow temperature maintenancerht DN 20 RH50T-20, RH55T-20, RH60T Return flow temperature maintenancerht DN 25 RH50T-25, RH55T-25, RH60T Return flow temperature maintenance with actuator DN 20 - DN 50 RHM Heating fittings Pump sets / Pump sets TK series K1 - K7 / TK 2 - TK Mixing valve actuators and equipment SR5, SR10, ST Ball valves / Thread connections MK..., PK..., TK..., KM Check valves SB..., ES, MR, MA, RSS Safety sets and heating equipment KSG, GAG, SID, GAK Stainless steel corrugated hose / Flexan EW, Flexan Domestic hot water modules as of page 187 Solar transfer stations as of page 211 Solar stations as of page 239 Index Subject index Item number index General Terms and Conditions / Manufacturer's warranty Fax order 283 Index Heating fittings RHT/RHM DN 40/50 01/2017 Printed in Germany PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu 5

6 PAW - Plant I High-quality products "Made in Germany" throughout the world! PAW - Plant II PAW - Plant III For over 50 years now, PAW has been supplying you with high-quality valves and fittings for heating systems, for solar thermal installations and for domestic hot water technology. Our product spectrum ranges from check valves, multivalves and specially designed valves to complete distribution systems for heating systems, solar thermal installations as well as for the preparation of domestic hot water. What began with valves and fittings has been steadily developed. Today, PAW offers modular groups of fittings in the heating sector for boilers with a nominal output of up to 400 kw, for solar thermal systems with a maximum nominal output of 200 kw and for domestic hot water modules with a maximum nominal output of 600 kw. This consistent development has resulted in high productivity and high-quality products. A constantly growing workforce ensures that administration and production lines run smoothly. Supported by competent specialised trade partners, we provide you with innovative products, helping you to stay ahead of your competitors. Do you have any questions? Our PAW team will be pleased to advise you! PAW - Team It takes courage, strength and enthusiasm to explore new ways 6 01/2017 Printed in Germany PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu

7 PAW - Your global partner... PAW head office and plant PAW GmbH & Co. KG Böcklerstraße 11 D Hameln info@paw.eu PAW subsidiary PAW VertriebsGmbH Buchenweg 798 A-8962 Gröbming office@paw.eu PAW subsidiary PAW VertriebsGmbH German office Berg 26a D Kirchdorf office@paw.eu PAW subsidiary with warehouse PAW sarl 67c, rue de la gare F Oberhoffen sur Moder fh@paw.eu PAW subsidiary PAW sarl German office Hopfengartenstraße 91 D Reutlingen ag@paw.eu PAW in North America PAW NA, Inc. 45 Davis Street USA-MA Webster support@paw.eu 01/2017 Printed in Germany PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu 7

8 General catalogue information On the following pages, you will find information on the layout of our catalogue, on the manufacturer's warranty, on PAW pumps, features and on PAW serial numbers. PAW manufacturer's warranty We grant a warranty of 5 years for all PAW fittings except for pumps, controllers and sensors - irrespective of the statutory provisions. See page 282 for more information. Features For all HeatBloCs of the nominal diameters DN 20 up to DN 50, you find symbols indicating the features in the order table. These symbols should facilitate your order and indicate at first glance, which HeatBloC is equipped with a pump and an actuator and which HeatBloC is delivered without these features. For an explanation of the symbols, see on the right. = with pump = with actuator = without pump PAW pumps The PAW pumps are Wilo or Grundfos pumps with the following advantages: fitted with 2 m cable completely preassembled exactly fitted into the insulation pressure tested with PAW serial number perfectly designed system pumps in conformity with the ErP/EuP directive See page 10/11 for an overview of the circulation pumps. Important note According to the European Ecodesign Directive ErP (Energy related Products) valid from , we only deliver high-efficiency pumps. AEO certification In 2011, PAW received the AEO certification and is now Authorized Economic Operator. The AEO certification implies that the company fulfills the required anti-terrorism standards and rigorously monitors the production processes. This certification attests that PAW is a reliable partner. We are certified: ISO 9001:2008 With this certificate the TÜV Rheinland attests that PAW pursues a quality management system according to the requirements of the DIN EN ISO 9001:2008. The scope of this certificate covers the development, production and sales of high quality heating and solar thermal installations. We are member of the platform VdZ HEIZUNGSlabel (VdZ heating label) From the 26th of September 2015 on, according to new European guidelines, heat generators, domestic hot water tanks, water heaters and combined systems must carry an energy label. It serves to inform the consumer about the energy efficiency of the labelled products. On the online platform VdZ HEIZUNGSlabel we provide you all the necessary data for labeling our products. SVGW/ACS certification Our domestic hot water products have SVGW and ACS certifications. All certificates as well as all data from this list can be downloaded as an Acrobat pdf-file in the Internet. Visit tab "Download". Subject to changes, errors excepted. 8 01/2017 Printed in Germany PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu

9 Catalogue information on serial numbers and PAW production system (PPS) PAW serial numbers PAW uses the serial number on almost all products since The serial number allows us to trace your HeatBloC or SolarBloC - back to the production. The serial number of the entire assembly is placed on the return pipe, the safety group or the Airstop so that it is clearly visible. Single components such as pumps, controller or actuators also have their own serial number. PAW documentation All PAW products are delivered with detailed installation and operation instructions in English, German, French, Spanish and Italian. Furthermore, we also offer commissioning protocols, data sheets, presentations, training and marketing documents for many products. From now on, you can find the instruction manual corresponding to your product with the serial number. Just scan the code of the serial number which is inside the installation. Under the tab Service/Documentation/PAW serial numbers, you will find an orientation aid where to find the serial number in the installation. Individual consultation The serial number guarantees optimum consultation in case of problems. Thanks to the serial number, our service team can access all the relevant data such as the list of items and the delivery date. They can check immediately whether the product is still under warranty and send you the required original spare part. By the way, we issue a 5-year warranty on PAW fittings. For further information, see page 282. If you need an individual consultation, do not hesitate to contact our service team via (serviceteam@paw.eu). PAW production system (PPS) At PAW, we constantly optimise our production and administration processes. "There is nothing that can not be improved!" is our slogan. Several times a year, employees from various departments of the company come together to examine work processes in detail. They creatively elaborate solutions off the beaten track. At the same time, their awareness of the fact that only a smooth collaboration between the departments will produce the optimum result for the customer increases steadily. 100% quality The PAW production system also implies that storage, transport and waiting times are reduced to a minimum. We only produce what is needed at a given point of time. By smoothing the work load, we create a continuous workflow. The processes are standardised and transparent, so that we can easily detect deviations from the target state and take corrective actions. Thus, we reduce wastefulness and provide for constant quality "made in Germany". 01/2017 Printed in Germany PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu 9

10 Overview High-efficiency pump types Controlled high-efficiency pumps with display Wilo-Stratos PICO Grundfos ALPHA2.1 Permanent magnet motor (ECM technology) Integrated electronic power control Differential pressure variable or constant (Δ p-v / Δ p-c ) LCD display for operation mode + power input Motor Power adjustment Control function Display Permanent magnet motor (ECM technology) Integrated electronic power control Differential pressure variable or constant (Δ p-v / Δ p-c ) LCD display for operation mode + power input selectable Night setback selectable < 0.20 EEI* < 0.17 Controlled high-efficiency pumps - Low Cost Wilo-Yonos PARA Grundfos UPM3 Auto L Permanent magnet motor (ECM technology) Integrated electronic power control Differential pressure variable or constant (Δ p-v / Δ p-c ) LED for "operating" and error code Motor Power adjustment Control function Display Permanent magnet motor (ECM technology) Integrated electronic power control Differential pressure variable or constant (Δ p-v / Δ p-c ) / constant revolution speed 5 LEDs for operation, operation mode and error code no Night setback no < 0.20 < 0.20 Grundfos UPM3 AUTO L: Display and plug description Push button to select the operation mode 5 LEDs for operation, operation mode and error code Control signal (PWM) at the front, plug of UPM3 AUTO L without function Anti-blocking screw operable from the front Mains plug accessible from the front * Energy Efficiency Index 10 01/2017 Printed in Germany PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu

11 Overview High-efficiency pump types Controlled high-efficiency pumps with high performance Wilo-Stratos PARA 30/1-12 Grundfos Magna Permanent magnet motor (ECM technology) Integrated electronic power control Differential pressure variable or constant (Δ p-v / Δ p-c ) Motor Power adjustment Control function Permanent magnet motor (ECM technology) Integrated electronic power control Differential pressure variable or constant (Δ p-v / Δ p-c ) no Display LED for operation mode Rotary knob as selector Operation Touch button no Night setback no < 0.23 EEI* < 0.21 Controlled high-efficiency pumps (flange version DN 40/50) - Low Cost Wilo-Yonos PARA HF /xx / PARA HF /xx Permanent magnet motor (ECM technology) Integrated electronic power control Differential pressure variable or constant (Δ p-v / Δ p-c ) LED for operation mode and error code Motor Power adjustment Control function Display Grundfos Magna Magna1 40-xxx F / Magna1 50-xxx F Permanent magnet motor (ECM technology) Integrated electronic power control Differential pressure variable or constant (Δ p-v / Δ p-c ) LED for operation mode and error code Rotary knob Operation Touch button no Night setback no < 0.20 EEI* < 0.21 Controlled high-efficiency pumps (flange version DN 40/50) Wilo-Stratos Stratos 50 1/xx Permanent magnet motor (ECM technology) Integrated electronic power control Differential pressure variable or constant (Δ p-v / Δ p-c ) Graphic display for operating conditions and type of control Motor Power adjustment Control function Display Grundfos Magna Magna3 40-xxx F / Magna 3 50-xxx F Permanent magnet motor (ECM technology) Integrated electronic power control Differential pressure variable or constant (Δ p-v / Δ p-c ) Graphic display for operating conditions and type of control Rotary knob Operation Touch button yes Night setback yes < 0.23 EEI* < 0.18 * Energy Efficiency Index 01/2017 Printed in Germany PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu 11

12 PAW heating technology - Dimensioning diagrams K31 - direct - DN 20-DN 50 Thermal output [kw] K32-3-way mixing valve - DN 20-DN 50 Flow rate [l/h] Thermal output [kw] Flow rate [l/h] K33(MAX) - controlled circuit with constant value - DN 20-DN 25 Thermal output [kw] Flow rate [l/h] 12 01/2017 Printed in Germany PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu

13 PAW heating technology - Dimensioning diagrams K34-3-way mixing valve with bypass - DN 20-DN 32 Thermal output [kw] Flow rate [l/h] K36(E) - boiler charging set - DN 20-DN 32 Thermal output [kw] K38-4-way mixing valve - DN 25-DN 32 Flow rate [l/h] Thermal output [kw] Flow rate [l/h] 01/2017 Printed in Germany PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu 13

14 PAW heating technology - Dimensioning tables t = 20 K - max. output / application range Nominal diameter DN 20 (¾") Page DN 25 (1") Page DN 32 (1¼") Page DN 40 (1½") Page DN 50 (2") Page K31 direct K32 3-way mixing valve K33 Controlled circuit with constant value K33MAX Controlled circuit with constant value K34 3-way mixing valve with bypass K35 3-temperature mixing valve K36(E) Boiler charging set K38 4-way mixing valve 30.0 kw kw kw kw kw kw kw kw kw kw kw kw kw kw kw kw kw kw kw kw 122 System separation 25.0 kw kw kw 124 MV Modular distribution manifold 50.0 kw kw kw kw kw 154 t = 10 K - max. output / application range Nominal diameter DN 20 (¾") Page DN 25 (1") Page DN 32 (1¼") Page DN 40 (1½") Page DN 50 (2") Page K31 direct K32 3-way mixing valve K33 Controlled circuit with constant value K33MAX Controlled circuit with constant value K34 3-way mixing valve with bypass K35 3-temperature mixing valve K36(E) Boiler charging set K38 4-way mixing valve 15.0 kw kw kw kw kw kw kw kw kw kw kw kw kw kw kw kw kw kw kw kw 122 System separation 12.5 kw kw kw 124 MV Modular distribution manifold 25.0 kw kw kw kw kw /2017 Printed in Germany PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu

15 PAW heating technology - Dimensioning tables t = 7,5 K - max. output / application range Nominal diameter DN 20 (¾") Page DN 25 (1") Page DN 32 (1¼") Page DN 40 (1½") Page DN 50 (2") Page K31 direct K32 3-way mixing valve K33 Controlled circuit with constant value K33MAX Controlled circuit with constant value K34 3-way mixing valve with bypass K35 3-temperature mixing valve K36(E) Boiler charging set K38 4-way mixing valve 11.0 kw kw kw kw kw kw kw kw kw kw kw kw kw kw kw kw kw kw kw kw 122 System separation 9.0 kw kw kw 124 MV Modular distribution manifold 18.5 kw kw kw kw kw 154 t = 5 K - max. output / application range Nominal diameter DN 20 (¾") Page DN 25 (1") Page DN 32 (1¼") Page DN 40 (1½") Page DN 50 (2") Page K31 direct K32 3-way mixing valve K33 Controlled circuit with constant value K33MAX Controlled circuit with constant value K34 3-way mixing valve with bypass K35 3-temperature mixing valve K36(E) Boiler charging set K38 4-way mixing valve 7.5 kw kw kw kw kw kw kw kw kw kw kw kw kw kw kw kw kw kw kw kw 122 System separation 6.0 kw kw kw 124 MV Modular distribution manifold 12.5 kw kw kw kw kw /2017 Printed in Germany PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu 15

16 Mounting example PAW house /2017 Printed in Germany PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu

17 Mounting example PAW house No. Illustration Application range 1 Domestic hot water module FriwaMini - DN 15 For hygienic DHW preparation. For further information, see page 192/ SolexMini - DN 15 For charging buffer and domestic hot water tanks. For further information, see page 218/ Return flow temperature maintenance K36 - DN 20 To maintain a minimum temperature in the boiler. For further information, see page 48/49. 4 HeatBloCs - DN 25 Modules for the application in hot water heating systems. For further information, see as of page /2017 Printed in Germany PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu 17

18 Mounting example PAW villa /2017 Printed in Germany PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu

19 Mounting example PAW villa No. Illustration Application range 1 Return flow temperature maintenance K36 - DN 20 To maintain a minimum temperature in the boiler. For further information, see page 48/49. 2 Domestic hot water module FriwaMidi - DN 20 For hygienic DHW preparation. For further information, see page 194/ SolexMidi - DN 20 For charging buffer and domestic hot water tanks. For further information, see page 220/ HeatBloCs - DN 25 Modules for the application in hot water heating systems. For further information, see as of page Boiler charging set K36E - DN 25 To maintain a minimum temperature in the boiler. For further information, see page 86/87. 01/2017 Printed in Germany PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu 19

20 Catalogue information on the hydraulic balancing HeatBloC MC - DN 25 Patent pending! Automatic, dynamic balancing of the distribution manifold 20 01/2017 Printed in Germany PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu

21 All advantages at a glance! Benefits for your customers: Cost and energy saving Optimum operation of the installation Gain in comfort No annoying whistling noises Intelligent system monitoring Possibility to obtain governmental subsidies Your advantages: Overall system solution for different application ranges (single- / multi-family house etc.) Planning reliability Fast project settlement Easy commissioning of the system Ihre Vorteile: Increased customer satisfaction thanks to gain in comfort Competitive advantage 01/2017 Printed in Germany PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu 21

22 The perfect PAW solution HeatBloC MC Your advantages are: EnEV-compliant hydraulic balancing No under- or oversupply of individual heating circuits No loss of comfort Easy commissioning of the system Easy system monitoring via free app Cost monitoring via app Possibility to obtain governmental subsidies 22 01/2017 Printed in Germany PAW GmbH & Co. KG D Hameln Germany Phone: Fax:

23 Intelligent system monitoring thanks to the app! Your advantages with the PAW app: Free download of the app Fast configuration of the heating circuits via app Intelligent system monitoring: All heating circuits at a glance! Overview of all heating circuits on the display Available free of charge in the Store! 01/2017 Printed in Germany PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu 23

24 Application examples Automatic, dynamic balancing of the distribution manifold HeatBloC MC41 BUS HeatBloC MC42 BUS HeatBloC MC43 24 V T RET T FL T RET T FL T RET T FL p 230 V p 230 V p PWM PWM PWM 230 V BUS Boiler control Optional MCom communication set MC41 MC42 MC43 HeatBloC Easy integration in already existing heating systems Balanced system in each operating point Autarkic control system: The HeatBloC s MCom regulate the revolution speed of the pumps, the boiler control switches the pumps on and off and regulates the flow temperature /2017 Printed in Germany PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu

25 Application examples Return flow temperature maintenance T RET HeatBloC MC46 PWM p T FL Electronic return flow temperature maintenance through controlled actuator of the mixing valve Flow rate independent of the mixing valve position Measurement of the flow rate, the temperatures, the revolution speed and identification of the mixing valve position Two non-return valves avoid gravity circulation Balancing without distribution manifold T RET HeatBloC MC45 p PWM T FL T RET HeatBloC MC42 p PWM T FL 4-way mixing valve permits a higher efficiency of the boiler, a better tank stratification and a cooling down of the heating circuit returns Stable regulation without mutual influence or modification of the mixing valve position 01/2017 Printed in Germany PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu 25

26 Conventional balancing of the distribution manifold Undersupply during parallel operation (optimised individual operation) Example 1 Initial state: Optimised individual operation Consequential problem: Undersupply during parallel operation Heating circuit 1 Heating circuit 2 Heating circuit 3 Heating circuit 1 Heating circuit 2 Heating circuit 3 Pump characteristic curve Pressure difference in m wc p Parallel operation Individual operation Control characteristic curve of the pump Initial state Flow rate in l/h Advantage: Energy-saving individual operation Disadvantages: Undersupply during parallel operation Raising of the heating characteristic curve or pump characteristic curve necessary Waste of energy Example 1: Undersupply during parallel operation All the control characteristic curves of the pumps are adjusted for individual operation. During the simultaneous operation (parallel operation) of several heating circuits, the pressure loss in the inlet increases, the system characteristic curve gets steeper. Along the control characteristic curve, the operating point shifts to the left and not upwards. Because of the revolution speed reduction, the generated pressure (Δp) is not sufficient. To counteract this undersupply, the heating characteristic curve and the control characteristic curve of the pump have been raised until now (see next page). Both measures lead to an increased energy consumption /2017 Printed in Germany PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu

27 Conventional balancing of the distribution manifold Oversupply during individual operation (optimised parallel operation) Example 2 Initial state: Optimised parallel operation Consequential problem: Oversupply during individual operation Heating circuit 1 Heating circuit 2 Heating circuit 3 Heating circuit 1 Heating circuit 2 Heating circuit 3 Pump characteristic curve Pressure difference in m wc Control characteristic curve of the pump Parallel operation Individual operation p Initial state Flow rate in l/h Advantage: Security of supply during parallel operation Disadvantages: Excessively high return temperatures, increased fuel consumption during individual operation Additional costs Occasional whistling noises Example 2: Oversupply during individual operation In the design state, all heating circuits are adjusted to each other, the control characteristic curve of the pump is higher than in example 1. If heating circuits are switched off during parallel operation (f. ex. during holidays), the other heating circuits are oversupplied. Along the control characteristic curve, the operating point shifts to the right and not downwards. Because of the revolution speed increase, too much pressure (Δp) is generated. Whistling noises, excessively high return temperatures and an increased energy consumption are the results. 01/2017 Printed in Germany PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu 27

28 Conventional balancing of the distribution manifold Operation with differential pressure controllers Example 3 Parallel operation with differential pressure controllers Individual operation with differential pressure controllers Heating circuit 1 Heating circuit 2 Heating circuit 3 Heating circuit 1 Heating circuit 2 Heating circuit 3 Pressure difference in m wc Pump characteristic curve Control characteristic curve of the pump Characteristic curve with differential pressure controller Parallel operation p p Individual operation Initial state Flow rate in l/h Advantages: Security of supply during individual and parallel operation No whistling noises Disadvantages: Extensive commissioning Permanently increased energy consumption Additional costs Example 3: Individual and parallel operation with differential pressure controllers The differential pressure controllers ensure a balanced heat distribution during individual and parallel operation. The differential pressure controllers cause an increased pressure loss during individual operation (Δp on the right) and parallel operation (Δp on the left). To overcome this pressure loss, a higher control characteristic curve than in example 2 has to be set, resulting in an even higher energy consumption. The differential pressure controllers are expensive and inflexible /2017 Printed in Germany PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu

29 Automatic, dynamic balancing of the distribution manifold The PAW solution! The PAW solution: Automatic balancing of the distribution manifold during parallel operation The PAW solution: Automatic balancing of the distribution manifold during individual operation HeatBloC MC41 HeatBloC MC42 HeatBloC MC43 HeatBloC MC41 HeatBloC MC42 HeatBloC MC43 Pump characteristic curve Pressure difference in m wc Control characteristic curves of the pump Parallel operation Individual operation Initial state Flow rate in l/h Advantages: Security of supply for all heating circuits Energy-saving individual and parallel operation No whistling noises Easy commissioning Perfect system monitoring via free app Gain in comfort and increased well-being Automatic, dynamic balancing of the distribution manifold: The PAW solution! Dynamic adjustment of the control characteristic curve ensures an energy-efficient individual and parallel operation. When connecting additional heating circuits, the operating point switches upwards (constant flow rate, no mutual influence). All heating circuits are steadily supplied, so that no underor oversupply occurs. No whistling noises due to excessively high pump pressure. The operating modes can be accessed at any time via the app. Measurement of the flow and return temperature, differential pressure measurement. 01/2017 Printed in Germany PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu 29

30 Which profitability? It is a matter of money! Investment costs Operating costs Total costs + 1x K31 / MC41 Example 1: Optimised individual operation (page 26) Can not be compared! Insufficient heat supply during parallel operation! Example 2: Optimised parallel operation (page 27) Example 3: Operation with mechanical differential pressure controllers (page 28) The PAW solution! HeatBloC MC (page 29) 390,- 390,- 673,- 2x K32 / MC42 1,295,- 1,295,- 1,861,- 3-fold modular distribution manifold 512,- 512,- 512,- + Connection set for MCom ,- + 3x differential pressure controller - 893, Installation costs connection of distribution manifold Condition for subsidies from BAFA/KfW fulfilled? 500,- 500,- 500,- No Yes Yes = Total investment 2,697,- 3,589,- 3,600,- x = + Save money thanks to the PAW solution! Average pump performance in W 17 W 40 W 10 W Runtime of the pump in h 6500 h 6500 h 6500 h Annual electricity costs 1 (28 ct/kwh) 93,- 218,- 55,- Annual base costs fuel (8 ct/kwh at kwh) Annual additional costs fuel (10 kwh/m 2 at 180 m 2 ) 1,440,- 1,440,- 1,440,- 144,- - - = Annual fuel costs 2 1,584,- 1,440,- 1,440,- 1+2 Annual operating costs (electricity + fuel) Total costs over a period of 10 years Additional costs over a period of 10 years compared to HeatBloC MC 1,677,- 1,658,- 1,495,- 19,465,- 20,173,- 18,546,- 919,- 1,627,- - Amortisation When do you start saving money thanks to the installation of a PAW MCom system in comparison to a standard system? 5.0 years 1 month Comparative system System characteristics No hydraulic balancing Undersupply No hydraulic balancing Oversupply, whistling noises High total costs Optimum energy-saving operation 30 01/2017 Printed in Germany PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu

31 Functional insulation Advantages of the functional insulation: EnEV-compliant insulation of the HeatBloC and the distribution manifold Reduction of heat losses through sealing lips protected by the utility model No stack effect Almost no thermal losses Thermal separation of the flow and the return EnEV-compliant insulation thickness Splash-water repellent Protection by the utility model! EnEV-compliant functional insulation Protection by the utility model! Sealing lips protected by the utility model 01/2017 Printed in Germany PAW GmbH & Co. KG D Hameln Germany Phone: Fax:

32 Useful information on the hydraulic balancing Why choose the hydraulic balancing? For the hydraulic balancing of a big heating installation, not only the radiators must be balanced but also the heating lines at the distribution manifold (= balancing of the distribution manifold). The balancing of the distribution manifold is a necessary condition for a functioning hydraulic balancing of the entire installation. Only both aspects together ensure a comfortable heating of all rooms and an energy-efficient operation of the circulation pumps and the heat generators. Numerous funding programmes promote and require a hydraulic balancing when modernising a heating system. Static or dynamic? A distinction is made between the static and the dynamic balancing. The static balancing is carried out by restrictors with a fixed setting based on the dimensioning flow rate. This method generally implies the selection of a presetting at the thermostatic valve or at the regulating valve of the lines. This leads to less disadvantages at the radiator because, during the heating season, the heating output of the radiators is adapted to the varying outside temperature via the weather-compensated flow temperature. For the balancing of the distribution manifold, however, we recommend a dynamic balancing based on a regulation of the differential pressure. The PAW solution for the balancing of the distribution manifold! Our HeatBloC s from the MC series operate an electronic regulation of the differential pressure and build up exactly the pressure needed to cover the heat demand through the revolution speed control of the pumps. This ensures a sufficient valve authority of the thermostatic valves and improves their regulating mode. Flow rate variations due to mutual influence of the heating lines and a modification of the mixing valve position are avoided. The HeatBloC s MC save approximately 50 % of the pump energy compared to mechanical differential pressure controllers because all the energy produced is used efficiently. As the investment costs are nearly the same, the acquisition of a HeatBloC MC is profitable from the first day on! 32 01/2017 Printed in Germany PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu

33 Notes 01/2017 Printed in Germany PAW GmbH & Co. KG D Hameln Germany Phone: Fax:

34

35 HeatBloC DN 20 Catalogue 01/2017 Systems, valves and fittings for the use in hot water heating systems Valid for the UK

36 PAW service app Free download of the app All information available at any time Download of instruction manuals, data sheets, flyers and catalogues Search for instruction manuals via serial number Find the contact person and PAW subsidiary in your vicinity Registration in the online shop... and much more! /2017 Printed in Germany PAW GmbH & Co. KG D Hameln Germany Phone: Fax:

37 Modular system DN 20 Mounting example Mounting example: Model house for the max. capacity of a distribution manifold DN 20 K32 - DN 20, Radiator circuit, top floor K33 - DN 20, Low-temperature heating, top floor K34 - DN 20, Radiant floor heating, basement K36 - DN 20, Solid fuel boiler K31 - DN 20, Boiler charging DN 20 01/2017 Printed in Germany PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu 37

38 Product range HeatBloC Heating circuits and modular distribution manifolds DN 20 All HeatBloC s offer the following advantages: Preassembled group of fittings for heating circuits DN 20 High flexibility during assembly modules can be combined as required Full port ball valve, gaskets of the spindle can be replaced during operation Flat-sealing connections ¾'' internal thread with 1" union nut for assembly on a PAW distribution manifold. With PAW mounting equipment, the HeatBloCs can be installed on wall brackets. Large ball valve handles, easy handling, visible closing position EnEV conform functional insulation made of durable elastic EPP, complete insulation of valves and fittings, ventilation opening to cool the pump the insulation for the distribution manifold is integrated in the heating circuit insulation Free access to the pump head Check valve in the return pipe can be opened, 200 mm wc, spring-loaded, thus suited for horizontal and overhead installation PAW mixing valve with suitable actuator Easy assembly and disassembly thanks to the smart PAW snap-in mechanism Flow on the right = standard The HeatBloC s can be delivered with flow on the left against additional charge. Flow and return line can be changed on site, also for heating circuits with mixing valve All water-carrying parts are made of brass Full metal thermometers can be pulled off, with immersion sleeve integrated in the ball valve PAW heating pumps with high-efficiency (ECM) technology fitted with 2 m cable, completely premounted, integrated in the insulation, pressure tested, with serial number, perfectly designed system, pump characteristics, EuP/ErP READY Pump can be isolated, so that it can be replaced without draining As of page 56, you will find the complete mounting equipment for the modular system DN /2017 Printed in Germany PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu

39 Product range HeatBloC Heating circuits and modular distribution manifolds DN 20 - Types K31 direct / unmixed K32 with 3-way mixing valve K33 Controlled circuit with constant value, 3-way mixing valve with bypass 0-50% DN 20 up to 30 kw* up to 21 kw* up to 5 kw* K34 3-way mixing valve with bypass 0-50% K36 Boiler charging set with thermal control valve Modular distribution manifold 2-fold, 3-fold, 4-fold, 5-fold, 6-fold up to 50 kw* for each boiler connection Hydraulic separators up to 21 kw* up to 10 kw* up to 2200 l/h *Temperature difference = 20 K 01/2017 Printed in Germany PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu 39

40 HeatBloC K31 - DN 20 (¾") direct / unmixed Application range for boiler charging, for modulating temperature heating systems Recommended range of application up to 30 kw 20 K up to 1300 l/h DN 20 Operating data Max. pressure 6 bars Max. operating temperature 110 C Kvs value 4.7 Technical data Dimensions Nominal diameter Connection generator Connection consumer DN 20 (¾") 1" external thread, flat sealing (1) Height 385 mm (2) Installation length 255 mm (3) Centre distance 90 mm (4) Width 180 mm Materials Valves and fittings Gaskets Insulation ¾" internal thread Brass EPDM / NBR EPP Differential pressure diagram HeatBloC K31 - DN 20 (¾") EEI* incl. Item no. / piece Wilo-Yonos PARA RS 15/6-RKA < WY6 - Wilo-Stratos PICO 15/1-6 < WH6 - Grundfos Alpha < GH6 - Grundfos UPM3 Auto L PP3 < GM6 - for pumps with 1" external thread x 130 mm Prices excl. VAT 01/2017 Printed in Germany with pump without pump with actuator *Energy Efficiency Index PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu

41 Mounting equipment K31 - DN 20 (¾") Overflow set for HeatBloCs DN See page 56 Wall bracket set DN SET - See page 56 Cutting-ring compression fittings ¾" d = 12 mm d = 15 mm d = 18 mm d = 22 mm - See page 56 Connection set DN See page 56 DN 20 Fitting for heat flowmeter DN See page 58 Flush and drain set DN See page 56 Coupling piece for overhead installation DN See page 57 Modular distribution manifold - DN fold fold fold fold fold - See page 52 Mounting plate DN See page 56 Wall bracket DN See page 56 Prices excl. VAT 01/2017 Printed in Germany PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu 41

42 HeatBloC K32 - DN 20 (¾") with 3-way mixing valve Application range for heating systems controlled by a mixing valve Recommended range of application up to 21 kw 20 K up to 905 l/h DN 20 Operating data Max. pressure 6 bars Max. operating temperature 110 C Kvs value 3.7 Technical data Dimensions Nominal diameter Connection generator Connection consumer DN 20 (¾") 1" external thread, flat sealing (1) Height 385 mm (2) Installation length 255 mm (3) Centre distance 90 mm (4) Width 180 mm Materials Valves and fittings Gaskets Insulation ¾" internal thread Brass EPDM / NBR EPP Differential pressure diagram HeatBloC K32 - DN 20 (¾") EEI* incl. Item no. / piece Wilo-Yonos PARA RS 15/6-RKA < MWY6 - Wilo-Stratos PICO 15/1-6 < MWH6 - Grundfos Alpha < MGH6 - Grundfos UPM3 Auto L PP3 < MGM6 - for pumps with 1" external thread x 130 mm 32053M - Wilo-Yonos PARA RS 15/6-RKA < WY6 - Wilo-Stratos PICO 15/1-6 < WH6 - Grundfos Alpha < GH6 - Grundfos UPM3 Auto L PP3 < GM6 - for pumps with 1" external thread x 130 mm Extra charge for assembly with flow on the left per HeatBloC (no discount possible) Prices excl. VAT 01/2017 Printed in Germany with pump without pump with actuator *Energy Efficiency Index PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu

43 Mounting equipment K32 - DN 20 (¾") Overflow set for HeatBloCs DN See page 56 Wall bracket set DN SET - See page 56 Cutting-ring compression fittings ¾" d = 12 mm d = 15 mm d = 18 mm d = 22 mm - See page 56 Connection set DN See page 56 DN 20 Fitting for heat flowmeter DN See page 58 Flush and drain set DN See page 56 Non-return valve DN See page 56 Modular distribution manifold - DN fold fold fold fold fold - See page 52 Actuator SR V V - See page 58 Coupling piece for overhead installation DN See page 57 Mounting plate DN See page 56 Wall bracket DN See page 56 Prices excl. VAT 01/2017 Printed in Germany PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu 43

44 HeatBloC K33 - DN 20 (¾") Controlled circuit with constant value, 3-way mixing valve with bypass 0-50% Application range for radiant floor heating, for low-temperature heating installations Recommended range of application up to 5 kw 10 K up to 430 l/h DN 20 Operating data Max. pressure 6 bars Max. operating temperature 110 C Kvs value 1.3 Technical data Dimensions Nominal diameter Connection generator Connection consumer DN 20 (¾") 1" external thread, flat sealing (1) Height 385 mm (2) Installation length 255 mm (3) Centre distance 90 mm (4) Width 180 mm Materials Valves and fittings Gaskets Insulation ¾" internal thread Brass EPDM / NBR EPP Differential pressure diagram HeatBloC K33 - DN 20 (¾") EEI* incl. Item no. / piece Wilo-Yonos PARA RS 15/6-RKA < WY6 - Wilo-Stratos PICO 15/1-6 < WH6 - Grundfos Alpha < GH6 - Grundfos UPM3 Auto L PP3 < GM6 - for pumps with 1" external thread x 130 mm Extra charge for assembly with flow on the left per HeatBloC (no discount possible) Prices excl. VAT 01/2017 Printed in Germany with pump without pump with actuator *Energy Efficiency Index PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu

45 Mounting equipment K33 - DN 20 (¾") Overflow set for HeatBloCs DN See page 56 Wall bracket set DN SET - See page 56 Cutting-ring compression fittings ¾" d = 12 mm d = 15 mm d = 18 mm d = 22 mm - See page 56 Connection set DN See page 56 DN 20 Fitting for heat flowmeter DN See page 58 Flush and drain set DN See page 56 Non-return valve DN See page 56 Modular distribution manifold - DN fold fold fold fold fold - See page 52 Conversion kit for changing the flow from flow on the left to flow on the right See page 57 from flow on the right to flow on the left Coupling piece for overhead installation DN See page 57 Mounting plate DN See page 56 - Wall bracket DN See page 56 Prices excl. VAT 01/2017 Printed in Germany PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu 45

46 HeatBloC K34 - DN 20 (¾") 3-way mixing valve with bypass 0-50% Application range for mixed low-temperature heating Recommended range of application up to 21 kw 20 K up to 905 l/h DN 20 Operating data Max. pressure 6 bars Max. operating temperature 110 C Kvs value 3.7 Technical data Dimensions Nominal diameter Connection generator Connection consumer DN 20 (¾") 1" external thread, flat sealing (1) Height 385 mm (2) Installation length 255 mm (3) Centre distance 90 mm (4) Width 180 mm Materials Valves and fittings Gaskets Insulation ¾" internal thread Brass EPDM / NBR EPP Differential pressure diagram HeatBloC K34 - DN 20 (¾") EEI* incl. Item no. / piece Wilo-Yonos PARA RS 15/6-RKA < MWY6 - Wilo-Stratos PICO 15/1-6 < MWH6 - Grundfos Alpha < MGH6 - Grundfos UPM3 Auto L PP3 < MGM6 - for pumps with 1" external thread x 130 mm 32063M - Wilo-Yonos PARA RS 15/6-RKA < WY6 - Wilo-Stratos PICO 15/1-6 < WH6 - Grundfos Alpha < GH6 - Grundfos UPM3 Auto L PP3 < GM6 - for pumps with 1" external thread x 130 mm Extra charge for assembly with flow on the left per HeatBloC (no discount possible) Prices excl. VAT 01/2017 Printed in Germany with pump without pump with actuator *Energy Efficiency Index PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu

47 Mounting equipment K34 - DN 20 (¾") Overflow set for HeatBloCs DN See page 56 Contact thermostat Q C - See page 58 Wall bracket set DN SET - See page 56 Cutting-ring compression fittings ¾" d = 12 mm d = 15 mm d = 18 mm d = 22 mm - See page 56 DN 20 Connection set DN See page 56 Fitting for heat flowmeter DN See page 58 Flush and drain set DN See page 56 Non-return valve DN See page 56 Modular distribution manifold - DN fold fold fold fold fold - See page 52 Actuator SR V V - See page 58 Coupling piece for overhead installation DN See page 57 Mounting plate DN See page 56 Wall bracket DN See page 56 Prices excl. VAT 01/2017 Printed in Germany PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu 47

48 HeatBloC K36 - DN 20 (¾") Boiler charging set with thermal control valve Application range return flow temperature maintenance for solid fuel boilers, wood firing and stove heating systems Recommended range of application up to 10 kw 10 K up to 860 l/h DN 20 Operating data Max. pressure 6 bars Max. operating temperature 110 C Kvs value 2.5 Technical data Dimensions Nominal diameter DN 20 (¾") Connection generator ¾" internal thread Connection consumer ¾" internal thread (1) Height 385 mm (2) Installation length 347 mm (3) Centre distance 90 mm (4) Width 180 mm Materials Valves and fittings Brass Gaskets EPDM / NBR Insulation EPP Differential pressure diagram HeatBloC K36 - DN 20 (¾") Opening temperature EEI* incl. Item no. / piece Wilo-Yonos PARA RS 15/6-RKA 50 C < WY6 - Wilo-Stratos PICO 15/ C < WH6 - Grundfos Alpha C < GH6 - Grundfos UPM3 Auto L PP3 50 C < GM6 - for pumps with 1" ext. thread x 130 mm 50 C Wilo-Yonos PARA RS 15/6-RKA 55 C < WY6 - Wilo-Stratos PICO 15/ C < WH6 - Grundfos Alpha C < GH6 - Grundfos UPM3 Auto L PP3 55 C < GM6 - for pumps with 1" ext. thread x 130 mm 55 C Wilo-Yonos PARA RS 15/6-RKA 60 C < WY6 - Wilo-Stratos PICO 15/ C < WH6 - Grundfos Alpha C < GH6 - Grundfos UPM3 Auto L PP3 60 C < GM6 - for pumps with 1" ext. thread x 130 mm 60 C Prices excl. VAT 01/2017 Printed in Germany with pump without pump with actuator *Energy Efficiency Index PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu

49 Description of function K36 - DN 20 (¾") The K36 should always be used with a buffer tank, if not, a hydraulic separator is mandatory. DN 20 Thermal control valve with bypass Functioning: The thermal valve shuts off the connection to the consumers, as long as the water in the boiler circuit is colder than the opening temperature of the thermal control valve. The pump in the K36 circulates the water in the boiler circuit through the automatic bypass in the K36 which is completely open. When the water in the boiler circuit has obtained the opening temperature (+/- 3 K) of the thermal control valve, the valve opens the connection from/to the consumers. The bypass shuts off to the same extent as the connection to the consumers is opened. The control valve opens the return line from the consumers and enables thus the water to circulate in the consumer circuit. The cold water from the consumer return line is mixed in the control valve with the hot water from the bypass. Depending on the temperature and the flow rate of the water from the return line, the thermal control valve shuts off or opens the line to the consumers. Thus the return line which leads to the boiler always remains at a certain temperature level. With rising temperature in the flow line of the boiler or with rising temperature from the return line of the consumers, the thermal control valve opens the connection to the consumers. The temperature of the return line of the boiler remains nearly constant (+/- 3 K). Please note: When the boiler output is controlled by the boiler temperature, the boiler must heat up 20 K above the opening temperature of the K36. Otherwise, there will not be enough power available for the consumers (the boiler output may be reduced before the thermal control valve opens completely). 01/2017 Printed in Germany PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu 49

50 Modular distribution system Thermax - DN 20 (¾") Application range for wall-mounted boilers Recommended range of application K31: up to 23 kw, 20 K up to 1000 l/h K32: up to 19 kw, 20 K up to 820 l/h DN 20 Operating data Max. pressure 6 bars Max. operating temperature 110 C Kvs value unmixed 4.7 Kvs value mixed 3.7 Kvs value distribution manifold 7.8 Technical data Dimensions Nominal diameter DN 20 (¾") Connection generator 1" ext./¾" int. thread Connection consumer ¾" internal thread (1) Width 408 mm (2) Centre distance 90 mm (3) Height 400 mm (4) Installation length 335 mm (5) Distance 291 mm (6) Depth 100 mm Materials Valves and fittings Brass Gaskets EPDM / NBR Insulation EPP / ABS Differential pressure diagram Thermax - K31-K32 - DN 20 EEI* incl. Item no. / piece 2 x Wilo-Stratos PICO 15/1-6 < WH6-2 x Wilo-Yonos PARA RS 15/6-RKA < WY6-2 x Grundfos Alpha < GH6-2 x Grundfos UPM3 Auto L PP3 < GM6 - Thermax - K32-K32 - DN 20 EEI* incl. Item no. / piece 2 x Wilo-Stratos PICO 15/1-6 < WH6-2 x Wilo-Yonos PARA RS 15/6-RKA < WY6-2 x Grundfos Alpha < GH6-2 x Grundfos UPM3 Auto L PP3 < GM6-50 Prices excl. VAT 01/2017 Printed in Germany with pump without pump with actuator *Energy Efficiency Index PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu

51 Description of function Thermax DN 20 (¾") DN 20 Installation beside the boiler: Thermax is directly mounted to the wall without distance pieces. Installation below the boiler: The pipes are installed between the Thermax (with distance pieces) and the wall. The Thermax system has been designed for applications with two different temperature levels. An application example: It can be connected to a consumer with a high flow temperature (such as a radiator) and a consumer with a low flow temperature (such as a radiant floor heating).. Bypass closed Bypass open Dimensions 01/2017 Printed in Germany PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu 51

52 Modular distribution manifold - DN 20 (¾") Application range modular design with patented thermal separation of flow and return chamber for outputs up to 50 kw (for each boiler connection) at a temperature difference of 20 K DN 20 Operating data Max. pressure 6 bars Max. operating temperature 110 C Kvs value 7.8 Technical data Dimensions Nominal diameter Connection generator Connection consumer Connection on the side Installation height Height insulation DN 20 (¾") ¾" internal thread x 1" external thread, flat sealing (bottom), 2 x for boiler connection, others plugged ¾" PAW flange for nut 1" (top) ¾" internal thread, sealed with plug, for safety group and expansion tank 80 mm 85 mm Centre distance 90 mm Materials Valves and fittings Gaskets Insulation Brass EPDM / NBR EPP shells Differential pressure diagram Modular distribution manifold - DN 20 (¾") Item no. / piece 2-fold Number of connections for HeatBloCs = 3 Width = 440 mm 3-fold Number of connections for HeatBloCs = 5 Width = 620 mm 4-fold Number of connections for HeatBloCs = 7 Width = 800 mm 5-fold Number of connections for HeatBloCs = 9 Width = 980 mm 6-fold Number of connections for HeatBloCs = 11 Width = 1160 mm Prices excl. VAT 01/2017 Printed in Germany PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu

53 Mounting equipment modular distribution manifold - DN 20 (¾") Extension module DN For the extension of already existing HeatBloCs The installation may only be made by qualified experts! Safety set DN See page 57 Connection set for diaphragm expansion tank - DN 20 (¾") See page 58 DN 20 Set extension pieces DN 20 - DN See page 57 Sealing for nut 2057 ¾" - See page 57 Wall bracket DN See page 56 Wall bracket DN 20 (¾") See page 56 Union nut '' int. thread - See page 57 Coupling piece for overhead installation DN 20 (¾") See page 57 Connection set DN 20 (¾") See page 56 Mounting plate DN 20 (¾") See page 56 Prices excl. VAT 01/2017 Printed in Germany PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu 53

54 Hydraulic separators - DN 20 (¾") Description of function DN 20 Hydraulic separators are used when there are one or more heat generating circuits/primary circuits with pump and one or more consumer/secondary circuits with distribution pump in one system. Due to the working conditions in such systems, pumps affect each other and changes in throughput and delivery height can occur. The hydraulic separator causes a neutralization of the connected circuits. Thus, the primary and secondary circuit can work independently. The flow in one circuit does not cause a flow in the other circuit when the pressure drop in the hydraulic separator is insignificant. When a hydraulic separator is used, each circuit (the primary and the secondary one) must be equipped with a pump. Thus, a heat generating circuit/primary circuit can be provided with constant throughput and a consumer circuit/secondary circuit can be provided with variable flow. These are the typical functioning conditions for modern heating and air conditioning systems. The figures on the left side show three possible conditions of hydraulic stability. Hydraulic separators - DN 20 (¾") Item no. / piece up to 2200 l/h Completely made of brass, completely insulated with EPP insulation, for the installation below a modular distribution manifold DN 20 or separately on the wall (vertically or horizontally). Connections: ¾" PAW flange for nut 1" (top) ¾" internal thread x 1" external thread, flat-sealing (bottom), 2 x for boiler connection, others plugged 2 ½" internal thread for immersion sleeve and fill and drain valve Width = 435 mm Installation height = 120 mm Centre distance = 270 mm up to 950 l/h Completely made of brass, with separate flow and return line, to be mounted under a single HeatBloC DN 20. The EPP insulation is integrated in the HeatBloC. Can also be installed under a distribution manifold DN 20 (with mounting plate item no. 3125) or separately in the pipe. For separate installation, two additional union nuts item no are required and the insulation must be provided on site. Connections: ¾" PAW flange for nut 1" (top) ¾" int. thread 1" ext. thread, flat sealing (bottom) 2 ¾" internal thread, sealed with plug (to the side) Width = 260 mm Installation height = 80 mm Centre distance = 90 mm 54 Prices excl. VAT 01/2017 Printed in Germany PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu

55 Mounting equipment hydraulic separators - DN 20 (¾") Immersion sleeves ½" ext. thread See page 57 Wall bracket DN See page 56 Fill and drain valve See page 183 Piping group DN KS1 - See page 58 DN 20 Conversion kit for low-loss header DN See page 58 Installation set DN See page 57 Mounting plate DN See page 56 Union nut '' int. thread - See page 57 Sealing for nut 2057 ¾" - See page 57 Low-loss header MVW DN 20 (¾") for boilers with integrated pump By means of the conversion kit (item no. 3143), the modular distribution manifolds get a bypass which connects the flow and return line without causing any resistance (low-loss header). It must be considered that the pump of the boiler circuit must deliver a higher flow rate than the consumer pumps need in total. Otherwise, unwanted circulations occur on the right or left end of the low-loss header. In that case a hydraulic separator (item no or 31421) must be installed below a distribution manifold. Please note: When you plan the system you must already check whether a low-loss header can be used. In combination with central heating boilers, hydraulic separators must be installed below / upstream of a distribution manifold as the boiler delivers a flow rate with a high temperature difference (leads to unwanted circulation in low-loss headers). Low-loss header MVW DN 20 (¾") Item no. / piece 2-fold Number of connections for HeatBloCs = 3 Width = 440 mm 3-fold Number of connections for HeatBloCs = 5 Width = 620 mm Prices excl. VAT 01/2017 Printed in Germany PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu 55

56 Equipment for modular system DN 20 Illustration Item no. / piece Overflow set DN with self-sealing counter-t-pieces and elbow gland, adjustment range 1-6 m wc, suitable for HeatBloC DN 20 Wall bracket set DN SET - Parts: Mounting plate, wall bracket, 2 x nut 1" Wall distance possible: mm Distance: 15 mm Cutting-ring compression fitting DN 20, d = 12 mm Cutting-ring compression fitting DN 20, d = 15 mm Cutting-ring compression fitting DN 20, d = 18 mm Cutting-ring compression fitting DN 20, d = 22 mm ¾" external thread, self-sealing with o-ring, with support sleeve, suitable for soft copper pipes. For temperatures up to 150 C. Connection set DN Consisting of 2 adapters with 1" nut and ¾" internal thread for connecting pipes with ¾" external thread below the modular distribution manifolds DN 20 (¾") Flush and drain set DN x counter-t-pieces with fill and drain valve, each equipped with an extension piece, permits to flush and drain individual HeatBloCs. Wall bracket DN Parts: 2 wall brackets as a set (steel, zinced), mounting equipment Wall distance possible: mm, distance: 15 mm For 5-fold modular distribution manifolds, we recommend to use 2 wall bracket sets. Non-return valve DN To be inserted into the PAW mixing valve. Prevents unwanted circulation, for example when various mixing valves are connected to one distribution manifold. The non-return valve can simply be inserted into the mixing valve. Mounting plate DN Parts: Mounting plate, 2 gaskets, 2 x nut 1", 2 x nipple adaptor 1" ext. thread x ¾" ext. thread for installation with flat sealings below a modular distribution manifold and for attaching wall brackets 56 Prices excl. VAT 01/2017 Printed in Germany PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu

57 Illustration Item no. / piece Sealing for nut DN asbestos-free Dimensions: 30,0 x 21,0 x 2,0 mm Safety set DN 20 up to 50 kw for distribution manifolds DN 20, with self-sealing counter T-piece ¾" x ½", outlet ¾" with cap for expansion tank, pressure relief valve ½" x ¾", 3 bars, up to 50 kw, pressure gauge 0-4 bars Conversion kit from flow on the left to flow on the right Conversion kit from flow on the right to flow on the left The conversion kit for changing the flow line is mandatory for mixing valves K33 with bypass at the front. DN 20 Coupling piece for overhead installation DN Coupling piece for overhead installation with flat sealings of a HeatBloC below a distribution manifold. Please note: When you use wall brackets, an additional mounting plate is necessary for installing a MV2 2-fold distribution manifold. Set extension pieces DN 20 - DN Set of adaptor pieces for the overhead installation of HeatBloCs DN 25 below distribution manifolds DN 20, centre distance changed from 90 mm to 125 mm, connections 1" nut x 1" flange (for nut 1½") flat sealing. Union nut DN 20 1'' internal thread Brass, to screw insertion pieces for soldering below a distribution manifold Installation set DN Consisting of 2 screw-in fittings with 1" internal thread x 1" external thread and 2 gaskets, for the connection of a hydraulic separator DN 20 below a distribution manifold DN 20 Immersion sleeve 6 mm x 30 mm Immersion sleeve 6 mm x 60 mm Immersion sleeve 6 mm x 60 mm Immersion sleeve 6 mm x 100 mm Immersion sleeve 6 mm x 150 mm for the installation of the temperature sensors (d = 6 mm) in the storage tank, in the collector and for the installation of the hydraulic separator. Please note: The immersion sleeves do not fit into the ball valves of the heating circuits of the current catalogue 01/2017! : self-sealing, with o-ring, bare brass, for sensor with a depth of 30 mm : standard, chromed brass, for sensor with a depth of 60 mm : standard, chromed brass, with valve extension (25 mm), for sensor with a depth of 60 mm : standard, chromed copper, for sensor with a depth of 100 mm : standard, chromed copper, for sensor with a depth of 150 mm Prices excl. VAT 01/2017 Printed in Germany PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu 57

58 Illustration Item no. / piece Piping group DN KS1 - Piping group for hydraulic separator, consisting of 2 pipe sections, union nuts and gaskets, for connection of a vertically mounted hydraulic separator below a PAW distribution manifold. Flat-sealing connection, completely insulated, outlet on the right or on the left. DN 20 Conversion kit for low-loss header DN for conversion into a distribution manifold with integrated hydraulic separator (low-loss header). Range of application up to 950 l/h, max. up to MV3-3-fold distribution manifold. Consisting of: two distance rings for a resistance-free connection of flow and return chamber, incl. screws and o-rings. Connection set for diaphragm expansion tank for assembly to distribution manifolds DN 20, with tank connector ¾", wall bracket and mounting equipment, armoured hose with bend ¾" x 700 mm, maximum tank diameter = 440 mm Fitting for heat flowmeter DN for DN 20 HeatBloCs, to be mounted above the insulation, top connection: ¾" internal thread, bottom connection: ¾" external thread Contact thermostat C Q Contact thermostat for limiting the flow temperature, adjustable from C PAW actuator SR2-2 Nm 230 V PAW actuator SR2-2 Nm 24 V Easy assembly and disassembly thanks to the patented PAW snap-in mechanism, with 1.5 m cable and mounting set for halting assembly on the PAW mixing valve, for weather-compensated control, due to the removable scale it is suited for flow on the right or left side, change-over switch for manual / automatic operation Technical data Electrical connection: 230 V - 50 Hz (705013), 24 V - 50/60 HZ, DC 24 V (705015) Input power: 1 W (705013), 0.5 W (705015) Torque: min. 2 Nm Setting time for 90 : 105 s (705013), 100 s (705015) 58 Prices excl. VAT 01/2017 Printed in Germany PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu

59 Notes 01/2017 Printed in Germany PAW GmbH & Co. KG D Hameln Germany Phone: Fax:

60

61 HeatBloC DN 25 Catalogue 01/2017 Systems, valves and fittings for the use in hot water heating systems Valid for the UK

62 Product range HeatBloC MC - DN 25 Heating circuits for the balancing of the distribution manifold All HeatBloC s MC offer the following advantages: Automatic, dynamic balancing of the distribution manifold Security of supply, high comfort, avoids mutual influence at the distribution manifold, no flow rate variation due to the mixing valve position any more, necessary condition for a hydraulic balancing of the radiators Replaces mechanical differential pressure controllers and hydraulic separators High efficiency due to the low return temperature, energy-saving operation of the pumps, energy saving due to the pumps of approx. 50 % compared to mechanical differential pressure controllers in each line Electronic controller Electronic regulation of the differential pressure, temperature measurement and temperature regulation if necessary (HeatBloC MC43), display of the flow rate and the heat quantity with Grundfos pump Preassembled group of fittings for heating circuits DN 25 High flexibility during assembly The modules can be used in nearly any combination Check valve in the return pipe Avoids gravity circulation, can be opened, 200 mm wc, spring-loaded Non-return valve in the mixing valve Avoids unwanted circulation at the distribution manifold, can be opened, 50 mm wc, spring-loaded Flow on the right = standard The flow and return line can be easily changed on site (also for heating circuits with mixing valve) All water-carrying parts are made of brass EnEV-compliant functional insulation Made of permanently elastic EPP, complete insulation of the valves and fittings with sealing lips, ventilation opening to cool the pump PAW heating circulation pumps with high-efficiency technology Fitted with 2 m cable, completely premounted, integrated in the insulation, pressure tested, with serial number, perfectly aligned system, dimensioning diagram, ErP READY The pump can be entirely isolated No draining necessary during servicing Optional integration in a smart home environment 62 01/2017 Printed in Germany PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu

63 Product range HeatBloC MC - DN 25 Heating circuits for the balancing of the distribution manifold - Types MC41 direct / unmixed MC42 3-way mixing valve MC43 Controlled circuit with constant value, 3-way mixing valve with bypass 0-50% up to 50 kw* up to 40 kw* up to 45.5 kw* MC44 3-way mixing valve with bypass 0-50% MC45 3-temperature mixing valve MC46 Boiler charging set with 3-way mixing valve DN 25 up to 45.5 kw* up to 32.5 kw* up to 45.5 kw* Modular distribution manifolds 2-fold, 3-fold, 4-fold, 5-fold, 6-fold MCom communication set up to 80 kw* per boiler connection *Temperature difference = 20 K 01/2017 Printed in Germany PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu 63

64 HeatBloC MC41 - DN 25 (1") direct / unmixed Application range for boiler charging for modulating temperature heating systems Recommended application range up to 50 kw 20 K up to 2150 l/h Operating data Maximum pressure 6 bars Maximum operating temperature 110 C Kvs value 7.2 Technical data Differential pressure diagram Dimensions DN 25 Nominal diameter Connection generator Connection consumer DN 25 (1") 1½" external thread, flat sealing 1" internal thread (1) Height 500 mm (2) Installation length 340 mm (3) Centre distance 125 mm (4) Width 250 mm Materials Valves and fittings Gaskets Insulation Brass AFM34 / EPDM EPP, EnEV conform HeatBloC MC41 - DN 25 (1") EEI* with Item no. / piece Grundfos UPM3 Hybrid 25-70, flow rate display < GU7 - Wilo-Yonos PARA RSTG 25/1-7.5 < WG8 - Accessories Connection set for MCom controller (mandatory) Wall power supply (24 V DC, RJ12, RS485) for the connection of the MCom controllers to the power supply. Please note: For the function of a MC system, one connection set is necessary, regardless of the number of the heating circuits. MCom communication set (optional) For WiFi communication with an Apple or Android terminal. The communication module is the condition for the integration in a smart home environment. 64 Prices excl. VAT 01/2017 Printed in Germany with pump without pump with actuator *Energy Efficiency Index PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu

65 HeatBloC MC42 - DN 25 (1") 3-way mixing valve Application range for heating systems controlled by a mixing valve Recommended application range up to 40 kw 20 K up to 1750 l/h Operating data Maximum pressure 6 bars Maximum operating temperature 110 C Kvs value 5.2 Technical data Dimensions Nominal diameter Connection generator Connection consumer DN 25 (1") 1½" external thread, flat sealing 1" internal thread (1) Height 500 mm (2) Installation length 340 mm (3) Centre distance 125 mm (4) Width 250 mm Materials Valves and fittings Gaskets Insulation Brass AFM34 / EPDM EPP, EnEV conform Differential pressure diagram HeatBloC MC42 - DN 25 (1") EEI* with Item no. / piece DN 25 Grundfos UPM3 Hybrid 25-70, flow rate display < MGU7 - Wilo-Yonos PARA RSTG 25/1-7.5 < MWG8 - Accessories Connection set for MCom controller (mandatory) Wall power supply (24 V DC, RJ12, RS485) for the connection of the MCom controllers to the power supply. Please note: For the function of a MC system, one connection set is necessary, regardless of the number of the heating circuits. MCom communication set (optional) For WiFi communication with an Apple or Android terminal. The communication module is the condition for the integration in a smart home environment. Prices excl. VAT 01/2017 Printed in Germany with pump without pump with actuator *Energy Efficiency Index PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu 65

66 HeatBloC MC43 - DN 25 (1") Controlled circuit with constant value, 3-way mixing valve with bypass 0-50% Application range For low-temperature heating systems controlled by a mixing valve Constant value control circuit or indication of the nominal temperature via smart home environment Recommended application range up to 45.5 kw 20 K up to 1940 l/h Operating data Maximum pressure 6 bars Maximum operating temperature 110 C Kvs value 6.0 Adjustment rangeof the bypass 0-50 % Technical data Differential pressure diagram Dimensions DN 25 Nominal diameter Connection generator Connection consumer DN 25 (1") 1½" external thread, flat sealing 1" internal thread (1) Height 500 mm (2) Installation length 340 mm (3) Centre distance 125 mm (4) Width 250 mm Materials Valves and fittings Gaskets Insulation Brass AFM34 / EPDM EPP, EnEV conform HeatBloC MC43 - DN 25 (1") EEI* with Item no. / piece Grundfos UPM3 Hybrid 25-70, flow rate display < MGU7 - Wilo-Yonos PARA RSTG 25/1-7.5 < MWG8 - Accessories Connection set for MCom controller (mandatory) Wall power supply (24 V DC, RJ12, RS485) for the connection of the MCom controllers to the power supply. Please note: For the function of a MC system, one connection set is necessary, regardless of the number of the heating circuits. MCom communication set (optional) For WiFi communication with an Apple or Android terminal. The communication module is the condition for the integration in a smart home environment. 66 Prices excl. VAT 01/2017 Printed in Germany with pump without pump with actuator *Energy Efficiency Index PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu

67 HeatBloC MC44 - DN 25 (1") 3-way mixing valve with bypass 0-50% Application range for low-temperature heating systems controlled by a mixing valve Recommended application range up to 45.5 kw 20 K up to 1940 l/h Operating data Maximum pressure 6 bars Maximum operating temperature 110 C Kvs value 6.0 Adjustment rangeof the bypass 0-50 % Technical data Dimensions Nominal diameter Connection generator Connection consumer DN 25 (1") 1½" external thread, flat sealing 1" internal thread (1) Height 500 mm (2) Installation length 340 mm (3) Centre distance 125 mm (4) Width 250 mm Materials Valves and fittings Gaskets Insulation Brass AFM34 / EPDM EPP, EnEV conform Differential pressure diagram HeatBloC MC44 - DN 25 (1") EEI* with Item no. / piece DN 25 Grundfos UPM3 Hybrid 25-70, flow rate display < MGU7 - Wilo-Yonos PARA RSTG 25/1-7.5 < MWG8 - Accessories Connection set for MCom controller (mandatory) Wall power supply (24 V DC, RJ12, RS485) for the connection of the MCom controllers to the power supply. Please note: For the function of a MC system, one connection set is necessary, regardless of the number of the heating circuits. MCom communication set (optional) For WiFi communication with an Apple or Android terminal. The communication module is the condition for the integration in a smart home environment. Prices excl. VAT 01/2017 Printed in Germany with pump without pump with actuator *Energy Efficiency Index PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu 67

68 HeatBloC MC45 - DN 25 (1") 3-temperature mixing valve Application range Heating installations with buffer tank and solar heating support Control of radiant floor and panel heating systems Recommended application range up to 32.5 kw 20 K up to 1400 l/h Operating data Maximum pressure 6 bars Maximum operating temperature 110 C DN 25 Technical data Dimensions Nominal diameter Connection generator Connection consumer DN 25 (1") 1½" external thread, flat sealing 1" internal thread (1) Height 500 mm (2) Installation length 340 mm (3) Centre distance 125 mm (4) Width 250 mm Materials Valves and fittings Gaskets Insulation Brass AFM34 / EPDM EPP, EnEV conform Differential pressure diagram (1) 100% return, Kvs value = 5.1 (2) 100% low-temperature flow, Kvs value = 4.1 (3) 100% high-temperature flow, Kvs value = 4.7 HeatBloC MC45 - DN 25 (1") EEI* with Item no. / piece Grundfos UPM3 Hybrid 25-70, flow rate display < MGU7 - Wilo-Yonos PARA RSTG 25/1-7.5 < MWG8 - Accessories Connection set for MCom controller (mandatory) Wall power supply (24 V DC, RJ12, RS485) for the connection of the MCom controllers to the power supply. Please note: For the function of a MC system, one connection set is necessary, regardless of the number of the heating circuits. MCom communication set (optional) For WiFi communication with an Apple or Android terminal. The communication module is the condition for the integration in a smart home environment. 68 Prices excl. VAT 01/2017 Printed in Germany with pump without pump with actuator *Energy Efficiency Index PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu

69 HeatBloC MC46 - DN 25 (1") Boiler charging set with 3-way mixing valve Application range Return flow temperature maintenance for solid fuel boilers, wood firing and stove heating systems for a constant flow rate in the heat generator Recommended application range up to 45.5 kw 20 K up to 1940 l/h Operating data Maximum pressure 6 bars Maximum operating temperature 110 C Kvs value 6.0 Technical data Dimensions Nominal diameter Connection generator Connection consumer DN 25 (1") 1½" external thread, flat sealing 1" internal thread (1) Height 500 mm (2) Installation length 340 mm (3) Centre distance 125 mm (4) Width 250 mm Materials Valves and fittings Gaskets Insulation Brass AFM34 / EPDM EPP, EnEV conform Differential pressure diagram DN 25 HeatBloC MC46 - DN 25 (1") EEI* with Item no. / piece Grundfos UPM3 Hybrid 25-70, flow rate display < GU7 - Wilo-Yonos PARA RSTG 25/1-7.5 < WG8 - with connection set for MCom controller Accessories MCom communication set (optional) For WiFi communication with an Apple or Android terminal. The communication module is the condition for the integration in a smart home environment. Prices excl. VAT 01/2017 Printed in Germany with pump without pump with actuator *Energy Efficiency Index PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu 69

70 Modular system DN 25 Mounting example Mounting example: Model house for maximum capacity of 80 kw of a distribution manifold DN 25 K31 - DN 25, Preparation of domestic hot water K32 - DN 25, Modulating temperature heating, top floor K32 - DN 25, Modulating temperature heating, basement System separation - DN 25, Radiant floor heating, basement K31 - DN 32, Boiler circuit DN /2017 Printed in Germany PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu

71 Modular system DN 25 Mounting example Mounting example: Distribution manifold DN 25 with solid fuel boiler, capacity of 40 kw K33 - DN 25, Small radiant floor heating K33MAX - DN 25, Low-temperature heating K34 - DN 25, Radiant floor heating K36E - DN 25, Solid fuel boiler DN 25 01/2017 Printed in Germany PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu 71

72 Product range HeatBloC Heating circuits and modular distribution manifolds DN 25 All HeatBloC s offer the following advantages: Preassembled group of fittings for heating circuits High flexibility during assembly modules can be combined as required Full port ball valve, gaskets of the spindle can be replaced during operation Flat-sealing connections 1½'' external thread with 1½" union nut for assembly on PAW distribution manifolds with PAW mounting equipment, the HeatBloCs can be installed on wall brackets Large ball valve handles, easy handling, visible closing position DN 25 EnEV-compliant functional insulation made of permanently elastic EPP, complete insulation of the valves and fittings with sealing lips, ventilation duct to cool the pump Free access to the pump head Check valve in the return pipe can be opened, 200 mm wc, spring-loaded, thus suited for horizontal and overhead installation PAW mixing valve with suitable actuator Easy assembly and disassembly thanks to the smart PAW snap-in mechanism Flow on the right = standard The HeatBloC s can be delivered with flow on the left against additional charge. Flow and return line can be changed on site, also for heating circuits with mixing valve All water-carrying parts are made of brass Full metal thermometers can be pulled off, with immersion sleeve integrated in the ball valve PAW heating pumps with high-efficiency (ECM) technology fitted with 2 m cable, completely premounted, integrated in the insulation, pressure tested, with serial number, perfectly designed system, pump characteristics, EuP/ErP READY Pump can be isolated, so that it can be replaced without draining As of page 98, you will find the complete mounting equipment for the modular system DN /2017 Printed in Germany PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu

73 Product range HeatBloC Heating circuits and modular distribution manifolds DN 25 - Types K31 direct / unmixed K32 with 3-way mixing valve K33 Controlled circuit with constant value, 3-way mixing valve with bypass 0-50% K33MAX Controlled circuit with constant value, 3-way mixing valve with bypass 0-50% up to 50 kw* up to 40 kw* up to 10 kw* up to 16 kw* K34 3-way mixing valve with bypass 0-50% K35 3-temperature mixing valve K36E Boiler charging set, with integrated overflow valve K38 with 4-way mixing valve DN 25 up to 45.5 kw* up to 32.5 kw* up to 40 kw* up to 33 kw* System separation Modular distribution manifold 2-fold, 3-fold, 4-fold, 5-fold, 6-fold up to 80 kw* for each boiler connection Hydraulic separators up to 3500 l/h up to 25 kw* *Temperature difference = 20 K 01/2017 Printed in Germany PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu 73

74 HeatBloC K31 - DN 25 (1") direct / unmixed Application range for boiler charging, for modulating temperature heating systems Recommended range of application up to 50 kw 20 K up to 2150 l/h Operating data Max. pressure 6 bars Max. operating temperature 110 C Kvs value 7.2 DN 25 Technical data Dimensions Nominal diameter Connection generator Connection consumer DN 25 (1") (1) Height 383 mm 1½" external thread, flat sealing 1" internal thread (2) Installation length 340 mm (3) Centre distance 125 mm (4) Width 250 mm Materials Valves and fittings Gaskets Insulation Brass EPDM EPP Differential pressure diagram HeatBloC K31 - DN 25 (1") EEI* incl. Item no. / piece Wilo-Stratos PICO 25/1-6 < WH6 - Wilo-Yonos PARA RS 25/6-RKA < WY6 - Wilo-Yonos PARA RS 25/7.5-RKA < WY8 - Grundfos UPM3 Auto L PP3 < GM6 - Grundfos Alpha < GH6 - Grundfos UPML Auto < GL9 - for pumps with 1½" ext. thread x 180 mm Prices excl. VAT 01/2017 Printed in Germany with pump without pump with actuator *Energy Efficiency Index PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu

75 Mounting equipment K31 - DN 25 (1") Wall bracket DN 25 - DN See page 99 Fitting for heat flowmeter DN 25 for unmixed HeatBloCs See page 98 K31 with fitting unmixed HeatBloC K31 DN 25 (1"), as described on the left, but with preassembled fitting for heat flowmeter, without pump Cutting-ring compression fittings 1" d = 15 mm d = 18 mm d = 22 mm - See page 99 Wall bracket set DN SET - See page 99 Connection set DN See page 99 DN 25 Flush and drain set DN See page 99 Modular distribution manifold - DN fold fold fold fold fold - See page 94 Wall bracket set for distribution manifolds See page 99 Mounting plate DN See page 98 Coupling piece for overhead installation DN See page 98 Wall bracket DN 25 - DN for HeatBloC - See page 99 Prices excl. VAT 01/2017 Printed in Germany PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu 75

76 HeatBloC K32 - DN 25 (1") with 3-way mixing valve Application range for heating systems controlled by a mixing valve Recommended range of application up to 40 kw 20 K up to 1750 l/h Operating data Max. pressure 6 bars Max. operating temperature 110 C Kvs value 5.7 DN 25 Technical data Dimensions Nominal diameter Connection generator Connection consumer DN 25 (1") (1) Height 383 mm 1½" external thread, flat sealing 1" internal thread (2) Installation length 340 mm (3) Centre distance 125 mm (4) Width 250 mm Materials Valves and fittings Gaskets Insulation Brass EPDM EPP Differential pressure diagram HeatBloC K32 - DN 25 (1") EEI* incl. Item no. / piece Wilo-Stratos PICO 25/1-6 < MWH6 - Wilo-Yonos PARA RS 25/6-RKA < MWY6 - Wilo-Yonos PARA RS 25/7.5-RKA < MWY8 - Grundfos UPM3 Auto L PP3 < MGM6 - Grundfos Alpha < MGH6 - Grundfos UPML Auto < MGL9 - for pumps with 1½" ext. thread x 180 mm 36053M - Wilo-Stratos PICO 25/1-6 < WH6 - Wilo-Yonos PARA RS 25/6-RKA < WY6 - Wilo-Yonos PARA RS 25/7.5-RKA < WY8 - Grundfos UPM3 Auto L PP3 < GM6 - Grundfos Alpha < GH6 - Grundfos UPML Auto < GL9 - for pumps with 1½" ext. thread x 180 mm Extra charge for assembly with flow on the left per HeatBloC (no discount possible) Prices excl. VAT 01/2017 Printed in Germany with pump without pump with actuator *Energy Efficiency Index PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu

77 Mounting equipment K32 - DN 25 (1") Wall bracket DN 25 - DN See page 99 Fitting for heat flowmeter DN 25 for mixed HeatBloCs See page 98 K32 with fitting mixed HeatBloC K32 DN 25 (1"), as described on the left, but with preassembled fitting for heat flowmeter, without pump Cutting-ring compression fittings 1" d = 15 mm d = 18 mm d = 22 mm - See page 99 Wall bracket set DN SET - See page 99 Actuator SR See page 100 Connection set DN See page 99 DN 25 Flush and drain set DN See page 99 Non-return valve for the mixing valve return See page 100 Modular distribution manifold - DN fold fold fold fold fold - See page 94 Mounting plate DN See page 98 Coupling piece for overhead installation DN See page 98 Wall bracket DN 25 - DN for HeatBloC - See page 99 Wall bracket set for distribution manifolds See page 99 Prices excl. VAT 01/2017 Printed in Germany PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu 77

78 HeatBloC K33 - DN 25 (1") Controlled circuit with constant value, 3-way mixing valve with bypass 0-50% Application range for radiant floor heating from 3.5 kw for low-temperature heating installations Recommended range of application up to 10 kw 10 K up to 860 l/h Operating data Max. pressure 6 bars Max. operating temperature 110 C Kvs value 3.0 DN 25 Technical data Dimensions Nominal diameter Connection generator Connection consumer DN 25 (1") (1) Height 383 mm 1½" external thread, flat sealing 1" internal thread (2) Installation length 340 mm (3) Centre distance 125 mm (4) Width 250 mm Materials Valves and fittings Gaskets Insulation Brass EPDM EPP Differential pressure diagram HeatBloC K33 - DN 25 (1") EEI* incl. Item no. / piece Wilo-Stratos PICO 25/1-6 < WH6 - Wilo-Yonos PARA RS 25/6-RKA < WY6 - Wilo-Yonos PARA RS 25/7.5-RKA < WY8 - Grundfos UPML Auto < GL9 - Grundfos Alpha < GH6 - Grundfos UPM3 Auto L PP3 < GM6 - for pumps with 1½" ext. thread x 180 mm Extra charge for assembly with flow on the left per HeatBloC (no discount possible) Prices excl. VAT 01/2017 Printed in Germany with pump without pump with actuator *Energy Efficiency Index PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu

79 Mounting equipment K33 - DN 25 (1") Wall bracket DN 25 - DN See page 99 Fitting for heat flowmeter DN 25 for mixed HeatBloCs See page 98 Cutting-ring compression fittings 1" d = 15 mm d = 18 mm d = 22 mm - See page 99 Wall bracket set DN SET - See page 99 Connection set DN See page 99 DN 25 Flush and drain set DN See page 99 Conversion kit for changing the flow line from flow on the left to flow on the right See page 183 from flow on the right to flow on the left Conversion kit for K33MAX for flow on the right See page 183 for flow on the left Coupling piece for overhead installation DN See page 98 Mounting plate DN See page 98 Wall bracket DN 25 - DN for HeatBloC - See page 99 Modular distribution manifold - DN fold fold fold fold fold - See page 94 Prices excl. VAT 01/2017 Printed in Germany PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu 79

80 HeatBloC K33MAX - DN 25 (1") Controlled circuit with constant value, 3-way mixing valve with bypass 0-50% Application range for thermally controlled radiant floors or walls, for low-temperature heating installations Recommended range of application up to 16 kw 10 K up to 1380 l/h Operating data Max. pressure 6 bars Max. operating temperature 110 C Kvs value 4.1 Adjustment rangeof the bypass 0-50 % Controller rangeof the thermostat C DN 25 Technical data Dimensions Nominal diameter Connection generator Connection consumer DN 25 (1") (1) Height 383 mm 1½" external thread, flat sealing 1" internal thread (2) Installation length 340 mm (3) Centre distance 125 mm (4) Width 250 mm Materials Valves and fittings Gaskets Insulation Brass EPDM EPP Differential pressure diagram HeatBloC K33MAX - DN 25 (1") EEI* incl. Item no. / piece Wilo-Stratos PICO 25/1-6 < WH6 - Wilo-Yonos PARA RS 25/6-RKA < WY6 - Wilo-Yonos PARA RS 25/7.5-RKA < WY8 - Grundfos UPML Auto < GL9 - Grundfos Alpha < GH6 - Grundfos UPM3 Auto L PP3 < GM6 - for pumps with 1½" ext. thread x 180 mm Extra charge for assembly with flow on the left per HeatBloC (no discount possible) Prices excl. VAT 01/2017 Printed in Germany with pump without pump with actuator *Energy Efficiency Index PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu

81 Mounting equipment K33MAX - DN 25 (1") Thermal control valve, adjustable Function 1. The thermal control valve keeps the flow line of the mixing valve completely open as long as the water from the flow line to the consumer is colder than the limit temperature of the thermal control valve. 2. When the water in the flow line has obtained the limit temperature (± 5 K) of the thermal control valve, the valve shuts off the flow line of the storage tank/modular distribution manifold and opens to the same extent the return line (coming from the consumers). The cold water from the return line is mixed in the control valve with the hot water from the flow line. Depending on the temperature, the thermal control valve opens or shuts off the flow line of the storage tank/modular distribution manifold. 3. With rising temperature in the flow line or rising temperature from the consumer return line, the thermal control valve shuts off the inlet of hot water. The temperature of the flow line to the heat exchanger/ consumer remains approximately constant (± 3K). Wall bracket DN 25 - DN See page 99 Wall bracket set DN SET - See page 99 Conversion kit for thermal control valve 34044R from flow on the left to flow on the right 34044L See page 183 from flow on the right to flow on the left - - Cutting-ring compression fittings 1" d = 15 mm d = 18 mm d = 22 mm - See page 99 Flush and drain set DN See page 99 Connection set DN See page 99 DN 25 Prices excl. VAT 01/2017 Printed in Germany PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu 81

82 HeatBloC K34 - DN 25 (1") 3-way mixing valve with bypass 0-50% Application range for mixed low-temperature heating Recommended range of application up to 45.5 kw 20 K up to 1940 l/h Operating data Max. pressure 6 bars Max. operating temperature 110 C Kvs value 6.0 DN 25 Technical data Dimensions Nominal diameter Connection generator Connection consumer DN 25 (1") (1) Height 383 mm 1½" external thread, flat sealing 1" internal thread (2) Installation length 340 mm (3) Centre distance 125 mm (4) Width 250 mm Materials Valves and fittings Gaskets Insulation Brass EPDM EPP Differential pressure diagram HeatBloC K34 - DN 25 (1") EEI* incl. Item no. / piece Wilo-Stratos PICO 25/1-6 < MWH6 - Wilo-Yonos PARA RS 25/6-RKA < MWY6 - Wilo-Yonos PARA RS 25/7.5-RKA < MWY8 - Grundfos Alpha < MGH6 - Grundfos UPM3 Auto L PP3 < MGM6 - Grundfos UPML Auto < MGL9 - for pumps with 1½" ext. thread x 180 mm 36063M - Wilo-Stratos PICO 25/1-6 < WH6 - Wilo-Yonos PARA RS 25/6-RKA < WY6 - Wilo-Yonos PARA RS 25/7.5-RKA < WY8 - Grundfos Alpha < GH6 - Grundfos UPM3 Auto L PP3 < GM6 - Grundfos UPML Auto < GL9 - for pumps with 1½" ext. thread x 180 mm Extra charge for assembly with flow on the left per HeatBloC (no discount possible) Prices excl. VAT 01/2017 Printed in Germany with pump without pump with actuator *Energy Efficiency Index PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu

83 Mounting equipment K34 - DN 25 (1") Wall bracket DN 25 - DN See page 99 Contact thermostat Q C - See page 100 Fitting for heat flowmeter DN 25 for mixed HeatBloCs See page 98 K34 with fitting HeatBloC K34 DN 25 (1") with 3-way mixing valve, as described on the left, but with preassembled fitting for heat flowmeter, without pump Connection set DN See page 99 Cutting-ring compression fittings 1" d = 15 mm d = 18 mm d = 22 mm - See page 99 Actuator SR See page 100 Wall bracket set DN SET - See page 99 DN 25 Flush and drain set DN See page 99 Modular distribution manifold - DN fold fold fold fold fold - See page 94 Coupling piece for overhead installation DN See page 98 Mounting plate DN See page 98 Wall bracket set for distribution manifolds See page 99 Wall bracket DN 25 - DN for HeatBloC - See page 99 Prices excl. VAT 01/2017 Printed in Germany PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu 83

84 HeatBloC K35 - DN 25 (1") 3-temperature mixing valve Application range Heating systems with buffer tank and solar heating support, control of radiant floor and panel heating systems Recommended range of application up to 32.5 kw 20 K up to 1400 l/h Operating data Max. pressure 6 bars Max. operating temperature 110 C DN 25 Technical data Dimensions Nominal diameter DN 25 (1") Connection generator 1½" ext. thread, flat sealing Connection consumer 1" internal thread (1) Height 383 mm (2) Installation length 340 mm (3) Centre distance 125 mm (4) Width 250 mm Materials Valves and fittings Brass Gaskets EPDM Insulation EPP Differential pressure diagram (1) 100% return, Kvs value = 5.1 (2) 100% low-temperature flow, Kvs value = 4.1 (3) 100% high-temperature flow, Kvs value = 4.7 HeatBloC K35 - DN 25 (1") EEI* incl. Item no. / piece Wilo-Stratos PICO 25/1-6 < MWH6 - Wilo-Yonos PARA RS 25/6-RKA < MWY6 - Wilo-Yonos PARA RS 25/7.5-RKA < MWY8 - Grundfos UPM3 Auto L PP3 < MGM6 - Grundfos Alpha < MGH6 - Grundfos UPML Auto < MGL9 - for pumps with 1½" ext. thread x 180 mm 36093M - Wilo-Stratos PICO 25/1-6 < WH6 - Wilo-Yonos PARA RS 25/6-RKA < WY6 - Wilo-Yonos PARA RS 25/7.5-RKA < WY8 - Grundfos UPM3 Auto L PP3 < GM6 - Grundfos Alpha < GH6 - Grundfos UPML Auto < GL9 - for pumps with 1½" ext. thread x 180 mm Extra charge for assembly with flow on the left per HeatBloC (no discount possible) Prices excl. VAT 01/2017 Printed in Germany with pump without pump with actuator *Energy Efficiency Index PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu

85 Description of function Mounting equipment K35 - DN 25 (1") Mounting example with two HeatBloCs K35 with 3-temperature mixing valve and piping (rear view) 3-temperature mixing valve Mixing valve position 2.5 Mixing valve position 7.5 DN 25 The 3-temperature mixing valve is used in combination with a buffer tank, which can be heated by either a solar thermal installation, a solid fuel boiler or a conventional boiler. If the consumer only needs a low temperature level, such as radiant panel heating systems, the 3-temperature mixing valve first takes the the flow water from the intermediate part of the storage tank. When the temperature in this part is no longer sufficient, the hot water from the upper part of the tank is used. By using two parts of the storage tank for two different flow temperatures, the energy from the buffer tank can be used more efficiently. The return temperatures are low and the stratification in the tank is maintained. Mounting equipment Item no. / piece Piping for one single HeatBloC K KS4 - Pipe set DN 25 to connect a mixing valve to a HeatBloC K35 Piping for two HeatBloCs K KS2 - Pipe set DN 25 to connect the connections on the backside, for the assembly of two HeatBloCs K35 on one distribution manifold. Extension pipe set for three HeatBloCs K KS3 - For installation of three HeatBloCs K35 the extension pipe set DN 25 is additionally required to extend 36092KS2. Prices excl. VAT 01/2017 Printed in Germany PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu 85

86 HeatBloC K36E - DN 25 (1") Boiler charging set with integrated overflow valve Application range return flow temperature maintenance for solid fuel boilers, wood firing and stove heating systems Recommended range of application up to 40 kw 20 K up to 1725 l/h Operating data Max. pressure 6 bars Max. operating temperature 110 C Kvs value 5.9 DN 25 Technical data Dimensions Nominal diameter DN 25 (1") Connection generator 1" internal thread Connection consumer 1½" internal thread (1) Height 383 mm (2) Installation length 408 mm (3) Centre distance 125 mm (4) Width 250 mm Materials Valves and fittings Brass Gaskets EPDM Insulation EPP Differential pressure diagram HeatBloC K36E - DN 25 (1") Opening temperature EEI* incl. Item no. / piece Wilo-Stratos PICO 25/ C < WH6 - Wilo-Yonos PARA RS 25/6-RKA 45 C < WY6 - Wilo-Yonos PARA RS 25/7.5-RKA 45 C < WY8 - Grundfos UPML Auto 45 C < GL9 - Grundfos Alpha C < GH6 - Grundfos UPM3 Auto L PP3 45 C < GM6 - for pumps with 1½" ext. thread x 180 mm 45 C Wilo-Stratos PICO 25/ C < WH6 - Wilo-Yonos PARA RS 25/6-RKA 60 C < WY6 - Wilo-Yonos PARA RS 25/7.5-RKA 60 C < WY8 - Grundfos UPML Auto 60 C < GL9 - Grundfos Alpha C < GH6 - Grundfos UPM3 Auto L PP3 60 C < GM6 - for pumps with 1½" ext. thread x 180 mm 60 C Prices excl. VAT 01/2017 Printed in Germany with pump without pump with actuator *Energy Efficiency Index PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu

87 Description of function K36E - DN 25 (1") The K36E should always be used with a buffer tank, if not, a hydraulic separator is mandatory. Thermal control valve with bypass Functioning: DN 25 The thermal valve shuts off the connection to the consumers, as long as the water in the boiler circuit is colder than the opening temperature of the thermal control valve. The pump in the K36E circulates the water in the boiler circuit by means of the automatic bypass which is completely open. When the water in the boiler circuit has obtained the opening temperature (+/- 3 K) of the thermal control valve, the valve opens the connection from/to the consumers. The bypass shuts off to the same extent as the connection to the consumers is opened. The control valve opens the return line from the consumers and thus enables the water to circulate in the consumer circuit. The cold water from the consumer return line is mixed in the control valve with the hot water from the bypass. Depending on the temperature and the flow rate of the water from the return line, the thermal control valve shuts off or opens the line to the consumers. Thus the return line which leads to the boiler always remains at a certain temperature level. With rising temperature in the flow line of the boiler or with rising temperature from the return line of the consumers, the thermal control valve opens the connection to the consumers. The temperature of the return line of the boiler remains nearly constant (+/- 3 K). Please note: When the boiler output is controlled by the boiler temperature, the boiler must heat up 20 K above the opening temperature of the K36E. Otherwise there will not be enough power available for the consumers (the boiler output may be reduced before the thermal control valve opens completely). Mounting equipment Item no. / piece Wall bracket for HeatBloC DN 25 (1") - DN 32 (1¼") Parts: Wall bracket (steel, zinced), mounting equipment DN 25: Wall distance possible = 150 mm DN 32: Wall distance possible = 180 mm Not required for installation with a PAW distribution manifold. Connection set DN 25 (1") fittings made of brass 1 ½" external thread x 1" internal thread, for connection of pipes with 1" external thread Prices excl. VAT 01/2017 Printed in Germany PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu 87

88 HeatBloC K38 - DN 25 (1") with 4-way mixing valve Application range for heating systems controlled by a mixing valve in combination with a boiler temperature maintenance Recommended range of application up to 33 kw 20 K up to 1400 l/h Operating data Max. pressure 6 bars Max. operating temperature 110 C Kvs value 4.1 DN 25 Technical data Dimensions Nominal diameter Connection generator Connection consumer DN 25 (1") (1) Height 383 mm 1½" external thread, flat sealing 1" internal thread (2) Installation length 340 mm (3) Centre distance 125 mm (4) Width 250 mm Materials Valves and fittings Gaskets Insulation Brass EPDM EPP Differential pressure diagram HeatBloC K38 - DN 25 (1") EEI* incl. Item no. / piece Wilo-Stratos PICO 25/1-6 < MWH6 - Wilo-Yonos PARA RS 25/6-RKA < MWY6 - Wilo-Yonos PARA RS 25/7.5-RKA < MWY8 - Grundfos Alpha < MGH6 - Grundfos UPM3 Auto L PP3 < MGM6 - Grundfos UPML Auto < MGL9 - for pumps with 1½" ext. thread x 180 mm 36083M - Wilo-Stratos PICO 25/1-6 < WH6 - Wilo-Yonos PARA RS 25/6-RKA < WY6 - Wilo-Yonos PARA RS 25/7.5-RKA < WY8 - Grundfos Alpha < GH6 - Grundfos UPM3 Auto L PP3 < GM6 - Grundfos UPML Auto < 0, GL9 - for pumps with 1½" ext. thread x 180 mm Prices excl. VAT 01/2017 Printed in Germany with pump without pump with actuator *Energy Efficiency Index PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu

89 Mounting equipment K38 - DN 25 (1") Wall bracket DN 25 - DN See page 99 Fitting for heat flowmeter DN 25 for mixed HeatBloCs See page 98 Connection set DN See page 99 Cutting-ring compression fittings 1" d = 15 mm d = 18 mm d = 22 mm - See page 99 Wall bracket set DN SET - See page 99 Actuator SR See page 100 DN 25 Flush and drain set DN See page 99 Non-return valve DN See page 99 Modular distribution manifold - DN fold fold fold fold fold - See page 94 Coupling piece for overhead installation DN See page 98 Mounting plate DN See page 98 Wall bracket DN 25 - DN for HeatBloC - See page 99 Wall bracket set for distribution manifolds See page 99 Prices excl. VAT 01/2017 Printed in Germany PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu 89

90 Extension set MCom - DN 25 (1") for heating circuits with 3-way mixing valve DN 25 Application range Extension of an already existing PAW heating circuit from the current series 2017, to a HeatBloC MC for the automatic, dynamic balancing of the distribution manifold Temperature sensor Pt1000 sensor for temperature measurement in the return measuring range: -20 C C blue mark for a clear assignment of the sensor Differential pressure sensor DPS measuring range: bars incl. brass fitting for the sensor and 2 x ½" union nut with connection cable Actuator 10 Nm / 24 V / 50 Hz constant control voltage manual operation possible controlled by MCom easy mounting through snap-in assembly on the PAW mixing valve Scope of delivery controller MCom 2 x temperature sensor Pt1000 differential pressure sensor DPS high-efficiency pump PAW actuator SR10 24/ST - 10 Nm 24 V Controller MCom autarkic controller for an automatic, dynamic balancing of the distribution manifold through an electronic regulation of the differential pressure, bars display of the flow rate values of the pump (Grundfos) Modbus for an optional integration in a smart home system with an external nominal value indication Temperature sensor Pt1000 sensor for temperature measurement in the return measuring range: -20 C C red mark for a clear assignment of the sensor High-efficiency pump fitted with 2 m cable with serial number ErP and EuP READY Technical data Operating data Max. operating temperature 110 C Max. pressure 6 bars Dimensions Height (controller) 200 mm Width (controller) 250 mm Centre distance 125 mm Materials Valves and fittings Brass Gaskets AFM34 Insulation EPP Differential pressure diagram Extension set MCom - DN 25 (1") EEI* Item no. / piece Grundfos UPM3 Hybrid < MGU7 - Wilo-Yonos PARA RSTG 25/7.5 < MWG8-90 Prices excl. VAT 01/2017 Printed in Germany *Energy Efficiency Index PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu

91 Extension set MCom - DN 25 (1") for direct / unmixed heating circuits Application range Extension of an already existing PAW heating circuit from the current series 2017, to a HeatBloC MC for the automatic, dynamic balancing of the distribution manifold Scope of delivery controller MCom 2 x temperature sensor Pt1000 differential pressure sensor DPS high-efficiency pump Temperature sensor Pt1000 sensor for temperature measurement in the return measuring range: -20 C C blue mark for a clear assignment of the sensor Differential pressure sensor DPS measuring range: bars incl. brass fitting for the sensor and 2 x ½" union nut with connection cable Controller MCom autarkic controller for an automatic, dynamic balancing of the distribution manifold through an electronic regulation of the differential pressure, bars display of the flow rate values of the pump (Grundfos) Modbus for an optional integration in a smart home system with an external nominal value indication Temperature sensor Pt1000 sensor for temperature measurement in the return measuring range: -20 C C red mark for a clear assignment of the sensor High-efficiency pump fitted with 2 m cable with serial number ErP and EuP READY DN 25 Technical data Operating data Max. operating temperature 110 C Max. pressure 6 bars Dimensions Height (controller) 200 mm Width (controller) 250 mm Centre distance 125 mm Materials Valves and fittings Brass Gaskets AFM34 Insulation EPP Differential pressure diagram Extension set MCom - DN 25 (1") EEI* Item no. / piece Grundfos UPM3 Hybrid < GU7 - Wilo-Yonos PARA RSTG 25/7.5 < WG8 - Prices excl. VAT 01/2017 Printed in Germany *Energy Efficiency Index PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu 91

92 System separation DN 25 (1") for HeatBloC s Application range Separation of the boiler circuit and the consumer circuit: for radiant panel heating systems with plastic pipes that are permeable to diffusion for the protection of new boilers in older heating installations Recommended application range depending on the heat exchanger and the pump used in the case of a pressure loss of 1.5 m wc up to 25 kw 10 K up to 2150 l/h Operating data Maximum pressure 6 bars Maximum operating temperature 110 C Kvs value (16 plates heat exchanger) 3.3 Kvs value (30 plates heat exchanger) 4.4 Kvs value (40 plates heat exchanger) 4.9 Equipment Pressure relief valve 3 bars, 50 kw Pressure gauge 0-4 bars Tank connection coupling Stainless steel corrugated hose: l = 700 mm Wall bracket: for tanks with a maximum diameter of 430 mm Fill and drain valve ¾" external thread x 3/8" external thread, self-sealing, with counter nut and hose connector Immersion sleeve for sensor: d=5.5 mm Vent plug (manual vent valve) ¾" external thread, self-sealing Technical data Dimensions Nominal diameter DN 25 (1") Connection generator 1" ext. thread / 1½" int. thread (nut) Connection consumer Connection for expansion tank ¾" 1" PAW flange (1) Height 176 mm (2) Installation length 176 mm (3) Centre distance 125 mm (4) Width 380 mm Materials Valves and fittings Gaskets Insulation Heat exchanger Brass EPDM EPP Solder: Copper Plates + connecting pieces: Stainless steel Differential pressure diagram System separation DN 25 (1") Heat exchanger Range of performance (in case of a pressure loss of 1.5 m wc) Item no. / piece 16 plates up to 20 kw at C prim. / C sec plates up to 23 kw at C prim. / C sec plates up to 25 kw at C prim. / C sec Mounting equipment Thread connection for PAW flange DN 25 (1") with union nut, fitting and gasket 92 Prices excl. VAT 01/2017 Printed in Germany *Energy Efficiency Index PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu

93 System separation DN 25 (1") for HeatBloC s Application examples Application 1: Extension of already existing heating circuits / Installations with a temperature control on the primary side (mixed heating circuit with controlled flow temperature or modulating boiler with boiler circuit pump) Recommended assembly: System separation+ sec.: HeatBloC K31 DN 25 incl. pump (see page <?>) EEI* Range of performance** 1430 l/h = 16.6 kw WH6 Wilo-Stratos PICO 25/ l/h = 19.3 kw l/h = 20.3 kw l/h = 18.3 kw WY6 Wilo-Yonos PARA RS 25/6-RKA l/h = 21.2 kw l/h = 22.4 kw l/h = 17.2 kw GH6 Grundfos Alpha l/h = 19.9 kw l/h = 20.8 kw l/h = 20.0 kw GM6 Grundfos UPM3 Auto L PP l/h = 23.5 kw l/h = 24.6 kw ** At a primary temperature of C, a secondary temperature of C and a secondary residual head of 1.5 m wc Application 2: Extension of already existing heating circuits / Installations with a pump on the primary side and high flow temperatures (bypass operation in addition to the radiator circuits or operation with solid fuel boiler and boiler circuit pump). Recommended assembly: System separation + sec.: HeatBloC K34 DN 25 incl. pump and actuator (see page <?>) EEI* Range of performance** l/h = 16.3 kw MWH6 Wilo-Stratos PICO 25/ l/h = 18.7 kw l/h = 19.6 kw l/h = 17.9 kw MWY6 Wilo-Yonos PARA RS 25/6-RKA l/h = 20.7 kw l/h = 21.6 kw l/h = 16.8 kw MGH6 Grundfos Alpha l/h = 19.2 kw l/h = 20.1 kw l/h = 19.6 kw MGM6 Grundfos UPM3 Auto L PP l/h = 22.6 kw l/h = 23.6 kw ** At a primary temperature of C, a secondary temperature of C and a secondary residual head of 1.5 m wc The assembly must be carried out on-site! Application 3: Complete separation system with mixing valve control on the primary side. Ensures low return temperatures of the boiler and allows the operation of several parallel heating circuits, f. ex. on a distribution manifold Recommended assembly: System separation + prim.: HeatBloC K32 DN 25 incl. pump and actuator (see page <?>) sec.: HeatBloC K31 DN 25 incl. pump (see page <?>) EEI* Range of performance** 1380 l/h = 16.0 kw prim MWH6 sec WH6 Wilo-Stratos PICO 25/ l/h = 18.5 kw l/h = 19.3 kw l/h = 17.9 kw prim MWY6 sec WY6 Wilo-Yonos PARA RS 25/6-RKA l/h = 20.3 kw l/h = 21.2 kw l/h = 16.7 kw prim MGH6 sec GH6 Grundfos Alpha l/h = 18.9 kw l/h = 19.9 kw l/h = 19.4 kw prim MGM6 sec GM6 Grundfos UPM3 Auto L PP l/h = 22.4 kw l/h = 23.2 kw ** At a primary temperature of C, a secondary temperature of C and a secondary residual head of 1.5 m wc Prices excl. VAT 01/2017 Printed in Germany *Energy Efficiency Index PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu 93

94 Modular distribution manifold - DN 25 (1") for the standard and MC series Application range modular design for outputs up to 80 kw (for each boiler connection) at a temperature difference of 20 K Operating data Max. pressure 6 bars Max. operating temperature 110 C Kvs value 2-fold 16.0 Kvs value 3-fold 18.0 Kvs value 4-fold 18.5 Kvs value 5-fold 19.0 Kvs value 6-fold 19.0 DN 25 Technical data Dimensions Nominal diameter Connection generator Connection consumer Installation height Height insulation DN 25 (1") 1½" external thread flat sealing (bottom), 2 x for boiler connection, others plugged 1" PAW flange for nut 1 ½" (top) 128 mm 137 mm Centre distance 125 mm Materials Valves and fittings Gaskets Insulation Brass/Polyamide EPDM EPP Differential pressure diagram Modular distribution manifold - DN 25 (1") Item no. / piece 2-fold Number of connections for HeatBloCs = 3 Width = 625 mm 3-fold Number of connections for HeatBloCs = 5 Width = 875 mm 4-fold Number of connections for HeatBloCs = 7 Width = 1125 mm 5-fold Number of connections for HeatBloCs = 9 Width = 1375 mm 6-fold Number of connections for HeatBloCs = 11 Width = 1625 mm Prices excl. VAT 01/2017 Printed in Germany PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu

95 Mounting equipment modular distribution manifold - DN 25 (1") Set extension pieces DN 25 - DN See page 98 Reducer set DN 25 - DN See page 98 Extension module DN For the extension of already existing HeatBloCs The installation may only be made by qualified experts! DN 25 Wall bracket set for distribution manifolds See page 99 Coupling piece for overhead installation DN 25 (1") See page 98 Mounting plate DN 25 (1") See page 98 Safety group DN 25 (1") up to 50 kw See page 100 MCom communication set Prices excl. VAT 01/2017 Printed in Germany PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu 95

96 Hydraulic separators - DN 25 (1") Description of function Hydraulic separators are used when there are one or more heat generating circuits/primary circuits with pump and one or more consumer/secondary circuits with distribution pump in one system. Due to the working conditions in such systems, pumps affect each other and changes in throughput and delivery height can occur. The hydraulic separator causes a neutralization of the connected circuits. Thus, the primary and secondary circuit can work independently. The flow in one circuit does not cause a flow in the other circuit when the pressure drop in the hydraulic separator is insignificant. When a hydraulic separator is used, each circuit (the primary and the secondary one) must be equipped with a pump. Thus, a heat generating circuit/primary circuit can be provided with constant throughput and a consumer circuit/secondary circuit can be provided with variable flow. These are the typical functioning conditions for modern heating and air conditioning systems. The figures on the left side show three possible conditions of hydraulic stability. DN 25 Hydraulic separators - DN 25 (1") Item no. / piece up to 3500 l/h Completely made of brass, completely insulated with EPP insulation, for the installation below a modular distribution manifold DN 25 or separately on the wall (vertically or horizontally). Connections: 1" PAW flange for nut 1 ½" (top) 1½" external thread / 1" internal thread, flat-sealing with threaded connection 2 ½" internal thread for immersion sleeve and fill and drain valve Width = 625 mm Installation height = 180 mm Centre distance = 375 mm up to 1600 l/h Completely made of brass, with separate flow and return line, for the installation below a HeatBloC DN 25. With EPP insulation. Can also be installed below a modular distribution manifold DN 25 (with mounting plate item no. 3425) or separately (in the pipe). When being installed separately, two additional connections sets (item no. 2151) are necessary. Connections: 1" PAW flange for nut 1 ½" (top) 1½" external thread, flat-sealing with threaded connection Width = 375 mm Installation height = 128 mm Centre distance = 125 mm 96 Prices excl. VAT 01/2017 Printed in Germany PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu

97 Mounting equipment hydraulic separators - DN 25 (1") Immersion sleeves ½" ext. thread mm x 60 mm - See page 99 Wall bracket set for distribution manifolds See page 99 Piping group DN KS1 - See page 100 Fill and drain valve See page 183 Mounting plate DN See page 98 Sealing for nut " - See page 177 DN 25 Conversion kit for low-loss header DN See page 100 Union nut ½'' int. thread - See page 177 Low-loss header MVW DN 25 (1") for boilers with integrated pump By means of the conversion kit (item no ), the modular distribution manifolds get a bypass which connects the flow and return line without causing any resistance (low-loss header). It must be considered that the pump of the boiler circuit must deliver a higher flow rate than the consumer pumps need in total. Otherwise, unwanted circulations occur on the right or left end of the low-loss header. In that case a hydraulic separator (item no or ) must be installed below a distribution manifold. Please note: When you plan the system you must already check whether a low-loss header can be used. In combination with central heating boilers, hydraulic separators must be installed below / upstream of a distribution manifold as the boiler delivers a flow rate with a high temperature difference (leads to unwanted circulation in low-loss headers). Low-loss header MVW DN 25 (1") Item no. / piece 2-fold Number of connections for HeatBloCs = 3 Width = 580 mm 3-fold Number of connections for HeatBloCs = 5 Width = 830 mm Prices excl. VAT 01/2017 Printed in Germany PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu 97

98 Equipment for modular system DN 25 Illustration Item no. / piece Fitting for heat flowmeter (direct HeatBloCs) DN The fitting can be used for all heat flowmeters (WMZ) with the connecting dimensions ¾" 110 mm and 1" x 130 mm. For heat flowmeters with other dimensions, the adapter set must be obtained by the customer. In the delivery included are the required flat-sealing fitting pieces, thus enabling to install additionally a heat flowmeter. The fitting is installed into the return line of the heating circuit. The sensors can be installed in the ½" sleeves of the thermometer ball valves (extensions might be necessary) or in connections of the customer. The immersion sleeve is not included in delivery. When the heat flowmeter is installed the front insulation may be adapted to the shape of the case (simply by cutting out). As the insulation is closed, it is recommended to install the heat flowmeter separately. The heat flowmeter is not included in delivery! Fitting for direct HeatBloCs DN 25 without mixing valve Consisting of: flat-sealing adapter set, 1 adapter pipe, seals, 1 pump ball valve with check valve and union nut. Fitting for heat flowmeter (mixed HeatBloCs) DN Fitting for HeatBloCs DN 25 with 3- or 4-wax mixing valve Consisting of: flat-sealing adapter set, 1 adapter pipe, seals, 1 non-return valve for the return of the mixing valve DN 25 Adapter pipe DN x 1½" external thread, flat sealing, length 180 mm, when an external circulation pump is used, to bridge the pump connection. Reducer set DN 25 - DN for installing DN 20 HeatBloCs on DN 25 distribution manifolds, adapter set 1½" external thread, flat sealing with nuts on ¾" PAW flange, reduction of the centre distance from 125 mm to 90 mm, distance pipe 1" internal thread x 1" external thread, flat sealing, brass, with sealings. The required union nuts 1" internal thread are dismounted from the HeatBloC. Set extension pieces DN 25 - DN for the assembly of HeatBloCs DN 32 on distribution manifolds DN 25, set of distance rings for union nut 2" internal thread on 1" PAW flange, made of brass, with special sealing, flat sealing Coupling piece for overhead installation DN Coupling piece for overhead installation with flat sealings of a HeatBloC below a distribution manifold. Please note: When you use wall brackets, an additional mounting plate is necessary for installing a MV2 2-fold distribution manifold. Mounting plate DN Parts: Mounting plate, 2 gaskets, 2 x nut 1 ½", 2 x housing of coupling F 1" x 1½" ext. thread for installation with flat sealings below a modular distribution manifold and for attaching wall brackets 98 Prices excl. VAT 01/2017 Printed in Germany PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu

99 Illustration Item no. / piece Wall bracket DN 25 - DN Zinced wall bracket for the wall assembly of a HeatBloC. Easy snap-in assembly of the HeatBloC on the wall bracket. Wall bracket for HeatBloC DN 25 - DN Parts: Wall bracket (steel, zinced), mounting equipment DN 25: Wall distance possible = 150 mm DN 32: Wall distance possible = 180 mm Not required for installation with a PAW distribution manifold. Wall bracket set for distribution manifolds Parts: 2 wall brackets as a set, steel, zinced, mounting equipment DN 25: Wall distance possible: 150mm DN 32: Wall distance possible: 180 mm From 5-fold modular distribution manifolds on, we recommend to use 2 wall bracket sets. Wall bracket set DN SET - Parts: 2 x nut 1 ½", mounting plate, wall bracket Wall distance possible: mm Immersion sleeve 6 mm x 30 mm Immersion sleeve 6 mm x 60 mm Immersion sleeve 6 mm x 60 mm Immersion sleeve 6 mm x 100 mm Immersion sleeve 6 mm x 150 mm for the installation of the temperature sensors (d = 6 mm) in the storage tank, in the collector and for the installation of the hydraulic separator. DN 25 Please note: The immersion sleeves do not fit into the ball valves of the heating circuits of the current catalogue 01/2017! : self-sealing, with o-ring, bare brass, for sensor with a depth of 30 mm : standard, chromed brass, for sensor with a depth of 60 mm : standard, chromed brass, with valve extension (25 mm), for sensor with a depth of 60 mm : standard, chromed copper, for sensor with a depth of 100 mm : standard, chromed copper, for sensor with a depth of 150 mm Cutting-ring compression fitting DN 25 d = 15 mm Cutting-ring compression fitting DN 25 d = 18 mm Cutting-ring compression fitting DN 25 d = 22 mm " external thread, self-sealing with o-ring, with support sleeve, suitable for soft copper pipes. For temperatures up to 150 C. Connection set DN 25-2x 1" int. thread Consisting of 2 insertion pieces for connection of pipes with 1" external thread below HeatBloCs or for the use of cutting-ring compression fittings. Flush and drain set DN x counter-t-pieces with fill and drain valve, each equipped with an extension piece, permits to flush and drain individual HeatBloCs. Non-return valve DN to be inserted into the PAW mixing valve. Prevents unwanted circulation for example when various mixing valves are connected to one distribution manifold. The non-return valve can simply be inserted into the mixing valve. For HeatBloC K38 - DN 25 Prices excl. VAT 01/2017 Printed in Germany PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu 99

100 Illustration Item no. / piece Non-return valve for the mixing valve return DN to be inserted into the PAW mixing valve. Prevents unwanted circulation for example when various mixing valves are connected to one distribution manifold. The non-return valve can simply be inserted into the mixing valve. Not suitable for HeatBloC K38 - DN 25. Piping group DN KS1 - Piping group for hydraulic separator, consisting of 2 pipe sections, union nuts and gaskets, for connection of a vertically mounted hydraulic separator below a PAW distribution manifold. Flat-sealing connection, completely insulated, outlet on the right or on the left. Conversion kit for low-loss header DN for conversion into a distribution manifold with integrated hydraulic separator (low-loss header). Range of application up to 1600 l/h, max. up to MV3-3-fold distribution manifold. Consisting of: two distance rings for a resistance-free connection of flow and return chamber, incl. screws and o-rings. Contact thermostat C Q Contact thermostat for limiting the flow temperature, adjustable from C DN 25 Safety group DN 25 up to 50 kw for the installation on a modular distribution manifold DN 25, with a connection of ¾" int. thread (sealed with plug) for the installation of the connection set for the expansion tank (item no. 7507), pressure relief valve ½" x ¾", 3 bars, up to 50 kw, pressure gauge 0-4 bars Connection set for diaphragm expansion tank for assembly to the safety group DN 25 with self-sealing double nipple ¾" and mounting equipment, tank connector ¾", armoured hose with bend ¾" x 700 mm, maximum tank diameter = 440 mm PAW actuator SR5-5 Nm 230 V Change-over switch for manual / automatic operation, simple assembly and disassembly thanks to the patented PAW snap-in mechanism, with 1.5 m cable and mounting set for halting assembly on the PAW mixing valve, for weather-compensated control, due to the removable scale it is suited for flow on the right or left side Technical data Electrical connection: Input power: Torque: Setting time for 90 : 230 V / 50 Hz 2.5 W 5 Nm 140 s PAW actuator SR10 24/3P - 10 Nm 24 V Like PAW actuator SR10 (item no ), but: with electrical connection/supply voltage 24 VAC for control systems with 3-level-control Technical data Electrical connection: Input power: Torque: Setting time for 90 : 24 V/50 Hz 1.5 W 10 Nm 140 s 100 Prices excl. VAT 01/2017 Printed in Germany PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu

101 Illustration Item no. / piece PAW actuator SR10 24/ST - 10 Nm 24 V Like PAW actuator SR10 (item no ), but: with electrical connection/supply voltage 24 VAC/DC control voltage direct: 0(2)...10 VDC for continuous control systems with 0 10 V output Technical data Electrical connection: Input power: Torque: Setting time for 90 : 24 V/50 Hz 1.5 W 10 Nm 140 s PAW actuator SR10-10 Nm 230 V Change-over switch for manual / automatic operation, simple assembly and disassembly thanks to the patented PAW snap-in mechanism, with 1.5 m cable and mounting set for halting assembly on the PAW mixing valve, for weather-compensated control, due to the removable scale it is suited for flow on the right or left side Technical data Electrical connection: Input power: Torque: Setting time for 90 : 230 V / 50 Hz 3.5 W 10 Nm 140 s Limit switch The limit switch is a micro switch. For the assembly in the actuators SR5 and SR10-24/3P. DN 25 Prices excl. VAT 01/2017 Printed in Germany PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu 101

102

103 HeatBloC DN 32 Catalogue 01/2017 Systems, valves and fittings for the use in hot water heating systems Valid for the UK

104 Product range HeatBloC MC - DN 32 Heating circuits for the balancing of the distribution manifold All HeatBloC s MC offer the following advantages: Automatic, dynamic balancing of the distribution manifold Security of supply, high comfort, avoids mutual influence at the distribution manifold, no flow rate variation due to the mixing valve position any more, necessary condition for a hydraulic balancing of the radiators Replaces mechanical differential pressure controllers and hydraulic separators High efficiency due to the low return temperature, energy-saving operation of the pumps, energy saving due to the pumps of approx. 50 % compared to mechanical differential pressure controllers in each line Electronic controller Electronic regulation of the differential pressure, temperature measurement and temperature regulation if necessary (HeatBloC MC43), display of the flow rate and the heat quantity with Grundfos pump Preassembled group of fittings for heating circuits High flexibility during assembly The modules can be used in nearly any combination Check valve in the return pipe Avoids gravity circulation, can be opened, 200 mm wc, spring-loaded Non-return valve in the mixing valve Avoids unwanted circulation at the distribution manifold, can be opened, 50 mm wc, spring-loaded DN 32 Flow on the right = standard The flow and return line can be easily changed on site (also for heating circuits with mixing valve) All water-carrying parts are made of brass EnEV-compliant functional insulation Made of permanently elastic EPP, complete insulation of the valves and fittings with sealing lips, ventilation opening to cool the pump PAW heating circulation pumps with high-efficiency technology Fitted with 2 m cable, completely premounted, integrated in the insulation, pressure tested, with serial number, perfectly aligned system, dimensioning diagram, ErP READY The pump can be entirely isolated No draining necessary during servicing Optional integration in a smart home environment /2017 Printed in Germany PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu

105 Product range HeatBloC MC - DN 32 Heating circuits for the balancing of the distribution manifold - Types MC41 direct / unmixed MC42 3-way mixing valve MC43 Controlled circuit with constant value, 3-way mixing valve with bypass 0-50% up to 65 kw* up to 51 kw* up to 64 kw* MC44 3-way mixing valve with bypass 0-50% MC46 Boiler charging set with 3-way mixing valve DN 32 up to 64 kw* up to 64 kw* Modular distribution manifolds 2-fold, 3-fold, 4-fold, 5-fold, 6-fold MCom communication set up to 150 kw* per boiler connection *Temperature difference = 20 K 01/2017 Printed in Germany PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu 105

106 HeatBloC MC41 - DN 32 (1¼") direct / unmixed Application range for boiler charging for modulating temperature heating systems Recommended application range up to 65 kw 20 K up to 2800 l/h Operating data Maximum pressure 6 bars Maximum operating temperature 110 C Kvs value 15.1 Technical data Differential pressure diagram Dimensions DN 32 Nominal diameter Connection generator Connection consumer DN 32 (1¼") (1) Height 557 mm 2" external thread, flat sealing (2) Installation length 400 mm (3) Centre distance 125 mm (4) Width 250 mm Materials Valves and fittings Gaskets Insulation 1¼" internal thread Brass AFM34 / EPDM EPP, EnEV conform HeatBloC MC41 - DN 32 (1¼") EEI* with Item no. / piece Grundfos UPM3 Hybrid 32-70, flow rate display < GU7 - Wilo-Yonos PARA-RSTG 30/7.5 < WG8 - Accessories Connection set for MCom controller (mandatory) Wall power supply (24 V DC, RJ12, RS485) for the connection of the MCom controllers to the power supply. Please note: For the function of a MC system, one connection set is necessary, regardless of the number of the heating circuits. MCom communication set (optional) For WiFi communication with an Apple or Android terminal. The communication module is the condition for the integration in a smart home environment. 106 Prices excl. VAT 01/2017 Printed in Germany with pump without pump with actuator *Energy Efficiency Index PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu

107 HeatBloC MC42 - DN 32 (1¼") 3-way mixing valve Application range for heating systems controlled by a mixing valve Recommended application range up to 51 kw 20 K up to 2200 l/h Operating data Maximum pressure 6 bars Maximum operating temperature 110 C Kvs value 9.6 Technical data Dimensions Nominal diameter Connection generator Connection consumer DN 32 (1¼") (1) Height 557 mm 2" external thread, flat sealing (2) Installation length 400 mm (3) Centre distance 125 mm (4) Width 250 mm Materials Valves and fittings Gaskets Insulation 1¼" internal thread Brass AFM34 / EPDM EPP, EnEV conform Differential pressure diagram HeatBloC MC42 - DN 32 (1¼") EEI* with Item no. / piece DN 32 Grundfos UPM3 Hybrid 32-70, flow rate display < MGU7 - Wilo-Yonos PARA-RSTG 30/7.5 < MWG8 - Accessories Connection set for MCom controller (mandatory) Wall power supply (24 V DC, RJ12, RS485) for the connection of the MCom controllers to the power supply. Please note: For the function of a MC system, one connection set is necessary, regardless of the number of the heating circuits. MCom communication set (optional) For WiFi communication with an Apple or Android terminal. The communication module is the condition for the integration in a smart home environment. Prices excl. VAT 01/2017 Printed in Germany with pump without pump with actuator *Energy Efficiency Index PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu 107

108 HeatBloC MC43 - DN 32 (1¼") Controlled circuit with constant value, 3-way mixing valve with bypass 0-50% Application range For low-temperature heating systems controlled by a mixing valve Constant value control circuit or indication of the nominal temperature via smart home environment Recommended application range up to 64 kw 20 K up to 2760 l/h Operating data Maximum pressure 6 bars Maximum operating temperature 110 C Kvs value 10.1 Adjustment rangeof the bypass 0-50 % Technical data Differential pressure diagram Dimensions DN 32 Nominal diameter Connection generator Connection consumer DN 32 (1¼") (1) Height 557 mm 2" external thread, flat sealing (2) Installation length 400 mm (3) Centre distance 125 mm (4) Width 250 mm Materials Valves and fittings Gaskets Insulation 1¼" internal thread Brass AFM34 / EPDM EPP, EnEV conform HeatBloC MC43 - DN 32 (1¼") EEI* with Item no. / piece Grundfos UPM3 Hybrid 32-70, flow rate display < MGU7 - Wilo-Yonos PARA-RSTG 30/7.5 < MWG8 - Accessories Connection set for MCom controller (mandatory) Wall power supply (24 V DC, RJ12, RS485) for the connection of the MCom controllers to the power supply. Please note: For the function of a MC system, one connection set is necessary, regardless of the number of the heating circuits. MCom communication set (optional) For WiFi communication with an Apple or Android terminal. The communication module is the condition for the integration in a smart home environment. 108 Prices excl. VAT 01/2017 Printed in Germany with pump without pump with actuator *Energy Efficiency Index PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu

109 HeatBloC MC44 - DN 32 (1¼") 3-way mixing valve with bypass 0-50% Application range for low-temperature heating systems controlled by a mixing valve Recommended application range up to 64 kw 20 K up to 2760 l/h Operating data Maximum pressure 6 bars Maximum operating temperature 110 C Kvs value 10.1 Adjustment rangeof the bypass 0-50 % Technical data Dimensions Nominal diameter Connection generator Connection consumer DN 32 (1¼") (1) Height 557 mm 2" external thread, flat sealing (2) Installation length 400 mm (3) Centre distance 125 mm (4) Width 250 mm Materials Valves and fittings Gaskets Insulation 1¼" internal thread Brass AFM34 / EPDM EPP, EnEV conform Differential pressure diagram HeatBloC MC44 - DN 32 (1¼") EEI* with Item no. / piece DN 32 Grundfos UPM3 Hybrid 32-70, flow rate display < MGU7 - Wilo-Yonos PARA-RSTG 30/7.5 < MWG8 - Accessories Connection set for MCom controller (mandatory) Wall power supply (24 V DC, RJ12, RS485) for the connection of the MCom controllers to the power supply. Please note: For the function of a MC system, one connection set is necessary, regardless of the number of the heating circuits. MCom communication set (optional) For WiFi communication with an Apple or Android terminal. The communication module is the condition for the integration in a smart home environment. Prices excl. VAT 01/2017 Printed in Germany with pump without pump with actuator *Energy Efficiency Index PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu 109

110 HeatBloC MC46 - DN 32 (1¼") Boiler charging set with 3-way mixing valve Application range Return flow temperature maintenance for solid fuel boilers, wood firing and stove heating systems for a constant flow rate in the heat generator Recommended application range up to 64 kw 20 K up to 2760 l/h Operating data Maximum pressure 6 bars Maximum operating temperature 110 C Kvs value 10.1 Technical data Differential pressure diagram Dimensions DN 32 Nominal diameter DN 32 (1¼") Connection generator 2" external thread Connection consumer 1¼" internal thread (1) Height 557 mm (2) Installation length 400 mm (3) Centre distance 125 mm (4) Width 250 mm Materials Valves and fittings Brass Gaskets AFM34 / EPDM Insulation EPP, EnEV conform HeatBloC MC46 - DN 32 (1¼") EEI* with Item no. / piece Grundfos UPM3 Hybrid 32-70, flow rate display < GU7 - Wilo-Yonos PARA-RSTG 30/7.5 < WG8 - with connection set for MCom controller Accessories MCom communication set (optional) For WiFi communication with an Apple or Android terminal. The communication module is the condition for the integration in a smart home environment. 110 Prices excl. VAT 01/2017 Printed in Germany with pump without pump with actuator *Energy Efficiency Index PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu

111 Notes 01/2017 Printed in Germany PAW GmbH & Co. KG D Hameln Germany Phone: Fax:

112 Modular system DN 32 Mounting example Mounting example: Distribution manifold DN 32 with boiler capacity up to 95 kw, optional use of solid fuel boiler (20 kw) System separation - DN 25, Radiant floor heating K31 - DN 32, Radiator circuit K34 - DN 25, Radiant floor heating K33 - DN 25, Small radiant floor heating K31 - DN 32, Boiler charging K36E - DN 32, Solid fuel boiler DN /2017 Printed in Germany PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu

113 Modular system DN 32 Mounting example Mounting example: Model house for max. capacity of a distribution manifold DN 32 K31 - DN 25, Boiler charging K32 - DN 32, Radiator circuit, basement, office K32 - DN 32, Radiator circuit, top floor, seminar rooms K34 - DN 32, Radiant floor heating, production hall DN 32 01/2017 Printed in Germany PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu 113

114 Product range HeatBloC Heating circuits and modular distribution manifolds DN 32 All HeatBloC s offer the following advantages: Preassembled group of fittings for heating circuits High flexibility during assembly modules can be combined as required Full port ball valve, gaskets of the spindle can be replaced during operation Flat-sealing connections 2" external thread with 2" union nut for assembly on a PAW distribution manifold. With PAW mounting equipment, the HeatBloCs can be installed on wall brackets. Large ball valve handles, easy handling, visible closing position EnEV-compliant functional insulation made of permanently elastic EPP, complete insulation of the valves and fittings with sealing lips, ventilation duct to cool the pump Free access to the pump head Check valve in the return pipe can be opened, 200 mm wc, spring-loaded, thus suited for horizontal and overhead installation DN 32 PAW mixing valve with suitable actuator Easy assembly and disassembly thanks to the smart PAW snap-in mechanism Flow on the right = standard The HeatBloC s can be delivered with flow on the left against additional charge. Flow and return line can be changed on site, also for heating circuits with mixing valve All water-carrying parts are made of brass Full metal thermometers can be pulled off, with immersion sleeve integrated in the ball valve PAW heating pumps with high-efficiency (ECM) technology fitted with 2 m cable, completely premounted, integrated in the insulation, pressure tested, with serial number, perfectly designed system, pump characteristics, EuP/ErP READY Pump can be isolated, so that it can be replaced without draining As of page 132, you will find the complete mounting equipment for the modular system DN /2017 Printed in Germany PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu

115 Product range HeatBloC Heating circuits and modular distribution manifolds DN 32 - Types K31 direct / unmixed K32 with 3-way mixing valve K34 3-way mixing valve with bypass 0-50% up to 65 kw* up to 51 kw* up to 64 kw* K36E Boiler charging set with integrated overflow valve K38 with 4-way mixing valve Modular distribution manifold 2-fold, 3-fold, 4-fold, 5-fold, 6-fold up to 150 kw* for each boiler connection DN 32 Hydraulic separators up to 60 kw* up to 52 kw* up to 4800 l/h *Temperature difference = 20 K 01/2017 Printed in Germany PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu 115

116 HeatBloC K31 - DN 32 (1¼") direct / unmixed Application range for boiler charging, for modulating temperature heating systems Recommended range of application up to 65 kw 20 K up to 2800 l/h Operating data Max. pressure 6 bars Max. operating temperature 110 C Kvs value 15.1 DN 32 Technical data Dimensions Nominal diameter Connection generator Connection consumer DN 32 (1¼") 2" ext. thread, flat sealing (1) Height 441 mm (2) Installation length 400 mm (3) Centre distance 125 mm (4) Width 250 mm Materials Valves and fittings Gaskets Insulation 1¼" internal thread Brass EPDM EPP Differential pressure diagram HeatBloC K31 - DN 32 (1¼") EEI* incl. Item no. / piece Wilo-Stratos PICO 30/1-6 < WH6 - Wilo-Yonos PARA RS 30/6-RKA < WY6 - Wilo-Yonos PARA HF 30/ < WY10 - Grundfos UPML Auto < GL9 - Grundfos Alpha < GH6 - Grundfos UPM3 Auto L PP3 < GM6 - for pumps with 2" ext. thread x 180 mm Prices excl. VAT 01/2017 Printed in Germany with pump without pump with actuator *Energy Efficiency Index PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu

117 Mounting equipment K31 - DN 32 (1¼") Wall bracket DN 25 - DN See page 133 Fitting for heat flowmeter DN 32 for unmixed HeatBloCs See page 132 Connection set DN See page 133 Wall bracket set DN SET - See page 133 Flush and drain set DN See page 132 DN 32 Coupling piece for overhead installation DN See page 133 Mounting plate DN See page 133 Wall bracket DN 25 - DN for HeatBloC - See page 133 Modular distribution manifold - DN fold fold fold fold fold - See page 128 Wall bracket set for distribution manifolds See page 133 Prices excl. VAT 01/2017 Printed in Germany PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu 117

118 HeatBloC K32 - DN 32 (1¼") with 3-way mixing valve Application range for heating systems controlled by a mixing valve Recommended range of application up to 51 kw 20 K up to 2200 l/h Operating data Max. pressure 6 bars Max. operating temperature 110 C Kvs value 9.6 DN 32 Technical data Dimensions Nominal diameter Connection generator Connection consumer DN 32 (1¼") 2" ext. thread, flat sealing (1) Height 441 mm (2) Installation length 400 mm (3) Centre distance 125 mm (4) Width 250 mm Materials Valves and fittings Gaskets Insulation 1¼" internal thread Brass EPDM EPP Differential pressure diagram HeatBloC K32 - DN 32 (1¼") EEI* incl. Item no. / piece Wilo-Stratos PICO 30/1-6 < MWH6 - Wilo-Yonos PARA RS 30/6-RKA < MWY6 - Wilo-Yonos PARA HF 30/ < MWY10 - Grundfos UPML Auto < MGL9 - Grundfos Alpha < MGH6 - Grundfos UPM3 Auto L PP3 < MGM6 - for pumps with 2" ext. thread x 180 mm 39053M - Wilo-Stratos PICO 30/1-6 < WH6 - Wilo-Yonos PARA RS 30/6-RKA < WY6 - Wilo-Yonos PARA HF 30/ < WY10 - Grundfos UPML Auto < GL9 - Grundfos Alpha < GH6 - Grundfos UPM3 Auto L PP3 < GM6 - for pumps with 2" ext. thread x 180 mm Extra charge for assembly with flow on the left per HeatBloC (no discount possible) Prices excl. VAT 01/2017 Printed in Germany with pump without pump with actuator *Energy Efficiency Index PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu

119 Mounting equipment K32 - DN 32 (1¼") Wall bracket DN 25 - DN See page 133 Fitting for heat flowmeter DN 32 for mixed HeatBloCs See page 132 Wall bracket set DN SET - See page 133 Actuator SR See page 134 Connection set DN See page 132 Flush and drain set DN See page 132 Non-return valve DN See page 133 Coupling piece for overhead installation DN See page 133 Modular distribution manifold - DN fold fold fold fold fold - See page 128 DN 32 Mounting plate DN See page 133 Wall bracket DN 25 - DN for HeatBloC - See page 133 Wall bracket set for distribution manifolds See page 133 Prices excl. VAT 01/2017 Printed in Germany PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu 119

120 HeatBloC K34 - DN 32 (1¼") 3-way mixing valve with bypass 0-50% Application range for mixed low-temperature heating Recommended range of application up to 64 kw 20 K up to 2760 l/h Operating data Max. pressure 6 bars Max. operating temperature 110 C Kvs value 10.1 DN 32 Technical data Dimensions Nominal diameter Connection generator Connection consumer DN 32 (1¼") 2" ext. thread, flat sealing (1) Height 441 mm (2) Installation length 400 mm (3) Centre distance 125 mm (4) Width 250 mm Materials Valves and fittings Gaskets Insulation 1¼" internal thread Brass EPDM EPP Differential pressure diagram HeatBloC K34 - DN 32 (1¼") EEI* incl. Item no. / piece Wilo-Stratos PICO 30/1-6 < MWH6 - Wilo-Yonos PARA RS 30/6-RKA < MWY6 - Wilo-Yonos PARA HF 30/ < MWY10 - Grundfos UPML Auto < MGL9 - Grundfos Alpha < MGH6 - Grundfos UPM3 Auto L PP3 < MGM6 - for pumps with 2" ext. thread x 180 mm 39063M - Wilo-Stratos PICO 30/1-6 < WH6 - Wilo-Yonos PARA RS 30/6-RKA < WY6 - Wilo-Yonos PARA HF 30/ < WY10 - Grundfos UPML Auto < GL9 - Grundfos Alpha < GH6 - Grundfos UPM3 Auto L PP3 < GM6 - for pumps with 2" ext. thread x 180 mm Extra charge for assembly with flow on the left per HeatBloC (no discount possible) Prices excl. VAT 01/2017 Printed in Germany with pump without pump with actuator *Energy Efficiency Index PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu

121 Mounting equipment K34 - DN 32 (1¼") Wall bracket DN 25 - DN See page 133 Contact thermostat Q C - See page 134 Fitting for heat flowmeter DN 32 for mixed HeatBloCs See page 132 Wall bracket set DN SET - See page 133 Actuator SR See page 134 Connection set DN See page 132 Flush and drain set DN See page 132 Coupling piece for overhead installation DN See page 133 Mounting plate DN See page 133 Wall bracket DN 25 - DN for HeatBloC - See page 133 Modular distribution manifold - DN fold fold fold fold fold - See page 128 Wall bracket set for distribution manifolds See page 133 DN 32 Prices excl. VAT 01/2017 Printed in Germany PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu 121

122 HeatBloC K36E - DN 32 (1¼") Boiler charging set with integrated overflow valve Application range return flow temperature maintenance for solid fuel boilers, wood firing and stove heating systems Recommended range of application up to 60 kw 20 K up to 2600 l/h Operating data Max. pressure 6 bars Max. operating temperature 110 C Kvs value 9.7 DN 32 Technical data Dimensions Nominal diameter DN 32 (1¼") Connection generator 1¼" internal thread Connection consumer 2" internal thread (1) Height 441 mm (2) Installation length 465 mm (3) Centre distance 125 mm (4) Width 250 mm Materials Valves and fittings Brass Gaskets EPDM Insulation EPP Differential pressure diagram HeatBloC K36E - DN 32 (1¼") Opening temperature EEI* incl. Item no. / piece Wilo-Stratos PICO 30/ C < WH6 - Wilo-Yonos PARA RS 30/6-RKA 45 C < WY6 - Wilo-Yonos PARA HF 30/ C < WY10 - Grundfos Alpha C < GH6 - Grundfos UPM3 Auto L PP3 45 C < GM6 - Grundfos UPML Auto 45 C < GL9 - for pumps with 2" ext. thread x 180 mm 45 C Wilo-Stratos PICO 30/ C < WH6 - Wilo-Yonos PARA RS 30/6-RKA 60 C < WY6 - Wilo-Yonos PARA HF 30/ C < WY10 - Grundfos Alpha C < GH6 - Grundfos UPM3 Auto L PP3 60 C < GM6 - Grundfos UPML Auto 60 C < GL9 - for pumps with 2" ext. thread x 180 mm 60 C Prices excl. VAT 01/2017 Printed in Germany with pump without pump with actuator *Energy Efficiency Index PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu

123 Description of function K36E - DN 32 (1¼") The K36E should always be used with a buffer tank, if not, a hydraulic separator is mandatory. Thermal control valve with bypass Functioning: The thermal valve shuts off the connection to the consumers, as long as the water in the boiler circuit is colder than the opening temperature of the thermal control valve. The pump in the K36E circulates the water in the boiler circuit by means of the automatic bypass which is completely open. When the water in the boiler circuit has obtained the opening temperature (+/- 3 K) of the thermal control valve, the valve opens the connection from/to the consumers. The bypass shuts off to the same extent as the connection to the consumers is opened. The control valve opens the return line from the consumers and thus enables the water to circulate in the consumer circuit. The cold water from the consumer return line is mixed in the control valve with the hot water from the bypass. Depending on the temperature and the flow rate of the water from the return line, the thermal control valve shuts off or opens the line to the consumers. Thus the return line which leads to the boiler always remains at a certain temperature level. DN 32 With rising temperature in the flow line of the boiler or with rising temperature from the return line of the consumers, the thermal control valve opens the connection to the consumers. The temperature of the return line of the boiler remains nearly constant (+/- 3 K). Please note: When the boiler output is controlled by the boiler temperature, the boiler must heat up 20 K above the opening temperature of the K36E. Otherwise there will not be enough power available for the consumers (the boiler output may be reduced before the thermal control valve opens completely). Mounting equipment Item no. / piece Wall bracket for HeatBloC DN 25 (1") - DN 32 (1¼") Parts: Wall bracket (steel, zinced), mounting equipment DN 25: Wall distance possible = 150 mm DN 32: Wall distance possible = 180 mm Not required for installation with a PAW distribution manifold. Connection set DN 32 (1¼") Connection set for DN 32 (1¼"), consisting of 2 screw-in fittings with 2" external thread and 1¼" internal thread for connecting pipes with 1¼" external thread. Prices excl. VAT 01/2017 Printed in Germany PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu 123

124 HeatBloC K38 - DN 32 (1¼") with 4-way mixing valve Application range for heating systems controlled by a mixing valve in combination with a boiler temperature maintenance Recommended range of application up to 52 kw 20 K up to 2240 l/h Operating data Max. pressure 6 bars Max. operating temperature 110 C Kvs value 6.1 DN 32 Technical data Dimensions Nominal diameter Connection generator Connection consumer DN 32 (1¼") 2" ext. thread, flat sealing (1) Height 441 mm (2) Installation length 400 mm (3) Centre distance 125 mm (4) Width 250 mm Materials Valves and fittings Gaskets Insulation 1¼" internal thread Brass EPDM EPP Differential pressure diagram HeatBloC K38 - DN 32 (1¼") EEI* incl. Item no. / piece Wilo-Stratos PICO 30/1-6 < MWH6 - Wilo-Yonos PARA RS 30/6-RKA < MWY6 - Wilo-Yonos PARA HF 30/ < MWY10 - Grundfos UPML Auto < MGL9 - Grundfos Alpha < MGH6 - Grundfos UPM3 Auto L PP3 < MGM6 - for pumps with 2" ext. thread x 180 mm 39083M - Wilo-Stratos PICO 30/1-6 < WH6 - Wilo-Yonos PARA RS 30/6-RKA < WY6 - Wilo-Yonos PARA HF 30/ < WY10 - Grundfos UPML Auto < GL9 - Grundfos Alpha < GH6 - Grundfos UPM3 Auto L PP3 < GM6 - for pumps with 2" ext. thread x 180 mm Prices excl. VAT 01/2017 Printed in Germany with pump without pump with actuator *Energy Efficiency Index PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu

125 Mounting equipment K38 - DN 32 (1¼") Wall bracket DN 25 - DN See page 133 Fitting for heat flowmeter DN 32 for mixed HeatBloCs See page 132 Wall bracket set DN SET - See page 133 Actuator SR See page 134 Connection set DN See page 132 Flush and drain set DN See page 132 Non-return valve DN See page 133 Coupling piece for overhead installation DN See page 133 Modular distribution manifold - DN fold fold fold fold fold - See page 128 DN 32 Mounting plate DN See page 133 Wall bracket DN 25 - DN for HeatBloC - See page 133 Wall bracket set for distribution manifolds See page 133 Prices excl. VAT 01/2017 Printed in Germany PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu 125

126 Extension set MCom DN 32 (1¼") for heating circuits with 3-way mixing valve Application range Extension of an already existing PAW heating circuit from the current series 2017, to a HeatBloC MC for the automatic, dynamic balancing of the distribution manifold Temperature sensor Pt1000 sensor for temperature measurement in the return measuring range: -20 C C blue mark for a clear assignment of the sensor Differential pressure sensor DPS measuring range: bars incl. brass fitting for the sensor and 2 x ½" union nut with connection cable Actuator 10 Nm / 24 V / 50 Hz constant control voltage manual operation possible controlled by MCom easy mounting through snap-in assembly on the PAW mixing valve Scope of delivery controller MCom 2 x temperature sensor Pt1000 differential pressure sensor DPS high-efficiency pump PAW actuator SR10 24/ST - 10 Nm 24 V Controller MCom autarkic controller for an automatic, dynamic balancing of the distribution manifold through an electronic regulation of the differential pressure, bars display of the flow rate values of the pump (Grundfos) Modbus for an optional integration in a smart home system with an external nominal value indication Temperature sensor Pt1000 sensor for temperature measurement in the return measuring range: -20 C C red mark for a clear assignment of the sensor High-efficiency pump fitted with 2 m cable with serial number ErP and EuP READY Technical data Operating data Max. operating temperature 110 C Max. pressure 6 bars Dimensions Height (controller) 200 mm Width (controller) 250 mm Centre distance 125 mm Materials Valves and fittings Brass Gaskets AFM34 Insulation EPP Differential pressure diagram Extension set MCom - DN 32 (1¼") EEI* Item no. / piece Grundfos UPM3 Hybrid < MGU7 - Wilo-Yonos PARA RSTG 30/7.5 < MWG8-126 Prices excl. VAT 01/2017 Printed in Germany *Energy Efficiency Index PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu

127 Extension set - DN 32 (1¼") for direct / unmixed heating circuits Application range Extension of an already existing PAW heating circuit from the current series 2017, to a HeatBloC MC for the automatic, dynamic balancing of the distribution manifold Scope of delivery controller MCom 2 x temperature sensor Pt1000 differential pressure sensor DPS high-efficiency pump Temperature sensor Pt1000 sensor for temperature measurement in the return measuring range: -20 C C blue mark for a clear assignment of the sensor Differential pressure sensor DPS measuring range: bars incl. brass fitting for the sensor and 2 x ½" union nut with connection cable Controller MCom autarkic controller for an automatic, dynamic balancing of the distribution manifold through an electronic regulation of the differential pressure, bars display of the flow rate values of the pump (Grundfos) Modbus for an optional integration in a smart home system with an external nominal value indication Temperature sensor Pt1000 sensor for temperature measurement in the return measuring range: -20 C C red mark for a clear assignment of the sensor High-efficiency pump fitted with 2 m cable with serial number ErP and EuP READY Technical data Operating data Max. operating temperature 110 C Maximum pressure 6 bars Dimensions Height (controller) 200 mm Width (controller) 250 mm Centre distance 125 mm Materials Valves and fittings Brass Gaskets AFM34 Insulation EPP Differential pressure diagram Extension set - DN 32 (1¼") EEI* Item no. / piece Grundfos UPM3 Hybrid < GU7 - Wilo-Yonos PARA RSTG 30/7.5 < WG8 - Prices excl. VAT 01/2017 Printed in Germany *Energy Efficiency Index PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu 127

128 Modular distribution manifold - DN 32 (1¼") for the standard and MC series Application range modular design for outputs up to 150 kw (for each boiler connection) at a temperature difference of 20 K Operating data Max. pressure 6 bars Max. operating temperature 110 C Kvs value 2-fold 34.0 Kvs value 3-fold 37.0 Kvs value 4-fold 38.0 Kvs value 5-fold 38.0 Kvs value 6-fold 38.0 DN 32 Technical data Dimensions Nominal diameter Connection generator Connection consumer Installation height Height insulation DN 32 (1¼") 2" external thread flat sealing (bottom), 2 x for boiler connection, others plugged 1¼" PAW flange for nut 2" (top) 156 mm 156 mm Centre distance 125 mm Materials Valves and fittings Gaskets Insulation Brass/Polyamide EPDM EPP Differential pressure diagram Modular distribution manifold - DN 32 (1¼") Item no. / piece 2-fold Number of connections for HeatBloCs = 3 Width = 625 mm 3-fold Number of connections for HeatBloCs = 5 Width = 875 mm 4-fold Number of connections for HeatBloCs = 7 Width = 1125 mm 5-fold Number of connections for HeatBloCs = 9 Width = 1375 mm 6-fold Number of connections for HeatBloCs = 11 Width = 1625 mm Prices excl. VAT 01/2017 Printed in Germany PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu

129 Mounting equipment modular distribution manifold - DN 32 (1¼") Extension module DN For the extension of already existing HeatBloCs The installation may only be made by qualified experts! Reducer set DN 32 - DN H = 11 mm - See page 133 Wall bracket set for distribution manifolds See page 133 Coupling piece for overhead installation DN 32 (1¼") See page 133 DN 32 Mounting plate DN 32 (1¼") See page 133 Safety group DN 32 (1¼") up to 100 kw See page 134 MCom communication set Prices excl. VAT 01/2017 Printed in Germany PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu 129

130 Hydraulic separators - DN 32 (1¼") Description of function Hydraulic separators are used when there are one or more heat generating circuits/primary circuits with pump and one or more consumer/secondary circuits with distribution pump in one system. Due to the working conditions in such systems, pumps affect each other and changes in throughput and delivery height can occur. The hydraulic separator causes a neutralization of the connected circuits. Thus, the primary and secondary circuit can work independently. The flow in one circuit does not cause a flow in the other circuit when the pressure drop in the hydraulic separator is insignificant. When a hydraulic separator is used, each circuit (the primary and the secondary one) must be equipped with a pump. Thus, a heat generating circuit/primary circuit can be provided with constant throughput and a consumer circuit/secondary circuit can be provided with variable flow. These are the typical functioning conditions for modern heating and air conditioning systems. The figures on the left side show three possible conditions of hydraulic stability. DN 32 Hydraulic separators - DN 32 (1¼") Item no. / piece up to 4800 l/h Completely made of brass, completely insulated with EPP insulation, for the installation below a modular distribution manifold DN 32 or separately on the wall (vertically or horizontally). Connections: 1¼" PAW flange for nut 2" (top) 1¼" internal thread / 2" external thread, flat sealing (bottom) with threaded connection 2 ½" internal thread for immersion sleeve and fill and drain valve Width = 600 mm Installation height = 200 mm Centre distance = 375 mm up to 2600 l/h Completely made of brass, with separate flow and return line, for the installation below a HeatBloC DN 32. With EPP insulation. Can also be installed below a modular distribution manifold DN 32 (with mounting plate item no. 3725) or separately (in the pipe). When being installed separately, two additional connections sets (item no. 2152) are necessary. Connections: 1¼" PAW flange for nut 2" (top) 2" external thread, flat-sealing with threaded connection Width = 330 mm Installation height = 125 mm Centre distance = 125 mm 130 Prices excl. VAT 01/2017 Printed in Germany PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu

131 Mounting equipment hydraulic separators - DN 32 (1¼") Immersion sleeves ½" ext. thread See page 132 Piping group DN KS1 - See page 133 Wall bracket set for distribution manifolds See page 133 Fill and drain valve See page 183 Mounting plate DN See page 133 Sealing for nut ¼" - See page 177 Conversion kit for low-loss header DN See page 133 Low-loss header MVW DN 32 (1¼") for boilers with integrated pump By means of the conversion kit (item no ), the modular distribution manifolds get a bypass which connects the flow and return line without causing any resistance (low-loss header). It must be considered that the pump of the boiler circuit must deliver a higher flow rate than the consumer pumps need in total. Otherwise, unwanted circulations occur on the right or left end of the low-loss header. In that case a hydraulic separator (item no or ) must be installed below a distribution manifold. Union nut '' int. thread - See page 177 Please note: When you plan the system you must already check whether a low-loss header can be used. In combination with central heating boilers, hydraulic separators must be installed below / upstream of a distribution manifold as the boiler delivers a flow rate with a high temperature difference (leads to unwanted circulation in low-loss headers). DN 32 Low-loss header MVW DN 32 (1¼") Item no. / piece 2-fold Number of connections for HeatBloCs = 3 Width = 600 mm 3-fold Number of connections for HeatBloCs = 5 Width = 850 mm Prices excl. VAT 01/2017 Printed in Germany PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu 131

132 Equipment for modular system DN 32 Illustration Item no. / piece Fitting for heat flowmeter (direct HeatBloCs) DN The fitting can be used for all heat flowmeters (WMZ) with the connecting dimensions 1" x 130 mm. For heat flowmeters with other dimensions, the adapter set must be obtained by the customer. In the delivery included are the required flat sealing fitting pieces, thus enabling to install additionally a heat flowmeter. The fitting is installed into the return line of the heating circuit. The sensors can be installed in the ½" sleeves of the thermometer ball valves (extensions might be necessary) or in connections of the customer. The immersion sleeve is not included in delivery. When the heat flowmeter is installed the front insulation may be adapted to the shape of the case (simply by cutting out). As the insulation is closed, it is recommended to install the heat flowmeter separately. The heat flowmeter is not included in delivery! Fitting for direct HeatBloCs DN 32 without mixing valve Consisting of: flat sealing adapter set, 1 adapter pipe, seals, 1 pump ball valve with check valve and union nut. Fitting for heat flowmeter (mixed HeatBloCs) DN Fitting for HeatBloCs DN 32 with 3- or 4-wax mixing valve Consisting of: flat sealing adapter set, 1 adapter pipe, seals, 1 non-return valve for the return of the mixing valve. DN 32 Immersion sleeve 6 mm x 30 mm Immersion sleeve 6 mm x 60 mm Immersion sleeve 6 mm x 60 mm Immersion sleeve 6 mm x 100 mm Immersion sleeve 6 mm x 150 mm for the installation of the temperature sensors (d = 6 mm) in the storage tank, in the collector and for the installation of the hydraulic separator. Please note: The immersion sleeves do not fit into the ball valves of the heating circuits of the current catalogue 01/2017! : self-sealing, with o-ring, bare brass, for sensor with a depth of 30 mm : standard, chromed brass, for sensor with a depth of 60 mm : standard, chromed brass, with valve extension (25 mm), for sensor with a depth of 60 mm : standard, chromed copper, for sensor with a depth of 100 mm : standard, chromed copper, for sensor with a depth of 150 mm Adapter pipe DN Brass, 2 x 2" external thread, flat sealing, length 180 mm, when an external circulation pump is used to bridge the pump connection Connection set DN Consisting of 2 insertion pieces for connection of pipes with 1¼" external thread below the HeatBloCs Flush and drain set DN x counter-t-pieces with fill and drain valve, each equipped with an extension piece, permits to flush and drain individual HeatBloCs. 132 Prices excl. VAT 01/2017 Printed in Germany PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu

133 Illustration Item no. / piece Non-return valve DN To be inserted into the PAW mixing valve. Prevents unwanted circulation, for example when various mixing valves are connected to one distribution manifold. The non-return valve can simply be inserted into the mixing valve. Coupling piece for overhead installation DN Coupling piece for overhead installation with flat sealings of a HeatBloC below a distribution manifold. Please note: When you use wall brackets, an additional mounting plate is necessary for installing a MV2 2-fold distribution manifold. Mounting plate DN Parts: mounting plate, 2 gaskets, 2 x nut 2" for installation with flat sealings below a modular distribution manifold and for attaching wall brackets Wall bracket DN 25 - DN Zinced wall bracket for the wall assembly of a HeatBloC. Easy snap-in assembly of the HeatBloC on the wall bracket. Wall bracket for HeatBloC DN 25 - DN Parts: Wall bracket (steel, zinced), mounting equipment DN 25: Wall distance possible = 150 mm DN 32: Wall distance possible = 180 mm Not required for installation with a PAW distribution manifold. Wall bracket set for distribution manifolds Parts: 2 wall brackets as a set, steel, zinced, mounting equipment DN 25: Wall distance possible: 150mm DN 32: Wall distance possible: 180 mm From 5-fold modular distribution manifolds on, we recommend to use 2 wall bracket sets. Wall bracket set DN SET - Parts: 2 x nut 2", mounting plate, wall bracket Wall distance possible: mm DN 32 Reducer set DN 32 - DN 25, H = 11 mm Reducer set DN 32 - DN 25, H = 24 mm for installing DN 25 HeatBloCs on DN 32 distribution manifolds, adapter set 2" external thread, flat sealing with nut on 1½" internal thread, flat sealing, made of brass, with gaskets, 2 types Piping group DN KS1 - Piping group for hydraulic separator, consisting of 2 pipe sections, union nuts and gaskets, for connection of a vertically mounted hydraulic separator below a PAW distribution manifold. Flat-sealing connection, completely insulated, outlet on the right or on the left. Conversion kit for low-loss header DN for conversion into a distribution manifold with integrated hydraulic separator (low-loss header). Range of application up to 2600 l/h, max. up to MV3-3-fold distribution manifold. Consisting of: two distance rings for a resistance-free connection of flow and return chamber, incl. screws and o-rings. Prices excl. VAT 01/2017 Printed in Germany PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu 133

134 Illustration Item no. / piece Contact thermostat C Q Contact thermostat for limiting the flow temperature, adjustable from C Safety group DN 32 up to 100 kw for the installation on a modular distribution manifold DN 32, with a connection of 1" int. thread (sealed with plug) for the installation of the connection set for the expansion tank (item no. 7508), pressure relief valve ¾" x 1", 3 bars, up to 100 kw, pressure gauge 0-4 bars Connection set for diaphragm expansion tank for assembly to the safety group DN 32 with self-sealing double nipple 1", cap valve 1", armoured hose with bend 1" x 700 mm. PAW actuator SR5-5 Nm 230 V Change-over switch for manual / automatic operation, simple assembly and disassembly thanks to the patented PAW snap-in mechanism, with 1.5 m cable and mounting set for halting assembly on the PAW mixing valve, for weather-compensated control, due to the removable scale it is suited for flow on the right or left side Technical data Electrical connection: Input power: Torque: Setting time for 90 : 230 V / 50 Hz 2.5 W 5 Nm 140 s DN 32 PAW actuator SR10-10 Nm 230 V Change-over switch for manual / automatic operation, simple assembly and disassembly thanks to the patented PAW snap-in mechanism, with 1.5 m cable and mounting set for halting assembly on the PAW mixing valve, for weather-compensated control, due to the removable scale it is suited for flow on the right or left side Technical data Electrical connection: Input power: Torque: Setting time for 90 : 230 V / 50 Hz 3.5 W 10 Nm 140 s PAW actuator SR10 24/3P - 10 Nm 24 V Like PAW actuator SR10 (item no ), but: with electrical connection/supply voltage 24 VAC for control systems with 3-level-control Technical data Electrical connection: Input power: Torque: Setting time for 90 : 24 V/50 Hz 1.5 W 10 Nm 140 s PAW actuator SR10 24/ST - 10 Nm 24 V Like PAW actuator SR10 (item no ), but: with electrical connection/supply voltage 24 VAC/DC control voltage direct: 0(2)...10 VDC for continuous control systems with 0 10 V output Technical data Electrical connection: Input power: Torque: Setting time for 90 : 24 V/50 Hz 1.5 W 10 Nm 140 s 134 Prices excl. VAT 01/2017 Printed in Germany PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu

135 Notes 01/2017 Printed in Germany PAW GmbH & Co. KG D Hameln Germany Phone: Fax:

136

137 HeatBloC DN 40/50 Catalogue 01/2017 Systems, valves and fittings for the use in hot water heating systems Valid for the UK

138 Product range HeatBloC MC - DN 40/50 Heating circuits for the balancing of the distribution manifold All HeatBloC s MC offer the following advantages: Automatic, dynamic balancing of the distribution manifold Security of supply, high comfort, avoids mutual influence at the distribution manifold, no flow rate variation due to the mixing valve position any more, necessary condition for a hydraulic balancing of the radiators Replaces mechanical differential pressure controllers and hydraulic separators High efficiency due to the low return temperature, energy-saving operation of the pumps, energy saving due to the pumps of approx. 50 % compared to mechanical differential pressure controllers in each line Electronic controller Electronic regulation of the differential pressure and temperature measurement Preassembled group of fittings for heating circuits High flexibility during assembly The modules can be used in nearly any combination Check valve in the return pipe Avoids gravity circulation, can be opened, 200 mm wc, spring-loaded Flow on the right = standard The flow and return line can be easily changed on site (also for heating circuits with mixing valve) All water-carrying parts are made of brass DN 40 EnEV-compliant functional insulation Made of permanently elastic EPP, complete insulation of the valves and fittings with sealing lips, ventilation opening to cool the pump PAW heating circulation pumps with high-efficiency technology Fitted with 2 m cable, completely premounted, integrated in the insulation, pressure tested, with serial number, perfectly aligned system, dimensioning diagram, ErP READY The pump can be entirely isolated No draining necessary during servicing Optional integration in a smart home environment /2017 Printed in Germany PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu

139 Product range HeatBloC MC - DN 40/50 Heating circuits for the balancing of the distribution manifold - Types MC41 - DN 40 (1½") direct / unmixed MC42 - DN 40 (1½") 3-way mixing valve Modular distribution manifold DN 40 (1½") 2-fold, 3-fold, 4-fold up to 150 kw* up to 125 kw* up to 250 kw* MC41 - DN 50 (2") direct / unmixed MC42 - DN 50 (2") 3-way mixing valve Modular distribution manifold DN 50 (2") 2-fold, 3-fold, 4-fold DN 40 up to 250 kw* up to 230 kw* up to 400 kw* *Temperature difference = 20 K 01/2017 Printed in Germany PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu 139

140 HeatBloC MC41 - DN 40 (1½") direct / unmixed Application range for boiler charging for modulating temperature heating systems Recommended application range up to 150 kw 20 K up to 6500 l/h Operating data Maximum pressure 6 bars Maximum operating temperature 110 C Kvs value 28.3 Technical data Differential pressure diagram Dimensions Nominal diameter DN 40 (1½") Connection generator Flange DN 40 / PN 6 Connection consumer 1½" internal thread (1) Height 790 mm (2) Installation length 560 mm (3) Centre distance 160 mm (4) Width 320 mm Materials Valves and fittings Brass Gaskets EPDM / NBR / AFM34 Insulation EPP, EnEV conform DN 40 HeatBloC MC41 - DN 40 (1½") EEI* with Item no. / piece Grundfos Magna F < GH12 - Accessories Connection set for MCom controller (mandatory) Wall power supply (24 V DC, RJ12, RS485) for the connection of the MCom controllers to the power supply. Please note: For the function of a MC system, one connection set is necessary, regardless of the number of the heating circuits. MCom communication set (optional) For WiFi communication with an Apple or Android terminal. The communication module is the condition for the integration in a smart home environment. 140 Prices excl. VAT 01/2017 Printed in Germany with pump without pump with actuator *Energy Efficiency Index PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu

141 HeatBloC MC42 - DN 40 (1½") 3-way mixing valve Application range for heating systems controlled by a mixing valve Recommended application range up to 125 kw 20 K up to 5400 l/h Operating data Maximum pressure 6 bars Maximum operating temperature 110 C Kvs value 17.7 Technical data Dimensions Nominal diameter DN 40 (1½") Connection generator Flange DN 40 / PN 6 Connection consumer 1½" internal thread (1) Height 790 mm (2) Installation length 560 mm (3) Centre distance 160 mm (4) Width 320 mm Materials Valves and fittings Brass Gaskets EPDM / NBR / AFM34 Insulation EPP, EnEV conform Differential pressure diagram HeatBloC MC42 - DN 40 (1½") EEI* with Item no. / piece Grundfos Magna F < MGH12 - DN 40 Accessories Connection set for MCom controller (mandatory) Wall power supply (24 V DC, RJ12, RS485) for the connection of the MCom controllers to the power supply. Please note: For the function of a MC system, one connection set is necessary, regardless of the number of the heating circuits. MCom communication set (optional) For WiFi communication with an Apple or Android terminal. The communication module is the condition for the integration in a smart home environment. Prices excl. VAT 01/2017 Printed in Germany with pump without pump with actuator *Energy Efficiency Index PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu 141

142 HeatBloC MC41 - DN 50 (2") direct / unmixed Application range for boiler charging for modulating temperature heating systems Recommended application range up to 250 kw 20 K up to l/h Operating data Maximum pressure 6 bars Maximum operating temperature 110 C Kvs value 31.2 Technical data Differential pressure diagram Dimensions Nominal diameter DN 50 (2") Connection generator Flange DN 40 / PN 6 Connection consumer 1½" internal thread (1) Height 850 mm (2) Installation length 630 mm (3) Centre distance 180 mm (4) Width 320 mm Materials Valves and fittings Brass Gaskets EPDM / NBR / AFM34 Insulation EPP, EnEV conform HeatBloC MC41 - DN 50 (2") EEI* with Item no. / piece Grundfos Magna F < GH12 - DN 50 Accessories Connection set for MCom controller (mandatory) Wall power supply (24 V DC, RJ12, RS485) for the connection of the MCom controllers to the power supply. Please note: For the function of a MC system, one connection set is necessary, regardless of the number of the heating circuits. MCom communication set (optional) For WiFi communication with an Apple or Android terminal. The communication module is the condition for the integration in a smart home environment. 142 Prices excl. VAT 01/2017 Printed in Germany with pump without pump with actuator *Energy Efficiency Index PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu

143 HeatBloC MC42 - DN 50 (2") 3-way mixing valve Application range for heating systems controlled by a mixing valve Recommended application range up to 230 kw 20 K up to 9980 l/h Operating data Maximum pressure 6 bars Maximum operating temperature 110 C Kvs value 25.7 Technical data Dimensions Nominal diameter DN 50 (2") Connection generator Flange DN 40 / PN 6 Connection consumer 1½" internal thread (1) Height 850 mm (2) Installation length 630 mm (3) Centre distance 180 mm (4) Width 360 mm Materials Valves and fittings Brass Gaskets EPDM / NBR / AFM34 Insulation EPP, EnEV conform Differential pressure diagram HeatBloC MC42 - DN 50 (2") EEI* with Item no. / piece Grundfos Magna F < MGH12 - DN 50 Accessories Connection set for MCom controller (mandatory) Wall power supply (24 V DC, RJ12, RS485) for the connection of the MCom controllers to the power supply. Please note: For the function of a MC system, one connection set is necessary, regardless of the number of the heating circuits. MCom communication set (optional) For WiFi communication with an Apple or Android terminal. The communication module is the condition for the integration in a smart home environment. Prices excl. VAT 01/2017 Printed in Germany with pump without pump with actuator *Energy Efficiency Index PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu 143

144 Modular system DN 40 Mounting example Mounting example: Distribution manifold DN 40 with 3 zones and a boiler capacity of up to 250 kw K34 - DN 32, Low-temperature heating with mixing valve, training centre K31 - DN 40, Air heater, production hall K32 - DN 40, Radiator circuit, office block DN /2017 Printed in Germany PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu

145 Modular system DN 50 Mounting example Mounting example: Distribution manifold DN 50 with 4 zones and a boiler capacity of up to 400 kw K32 - DN 40, Radiator circuit, basement, office K32 - DN 50, Radiator circuit, top floor, office K31 - DN 50, Radiator circuit, production hall K31 - DN 32, Preparation of domestic hot water DN 40 01/2017 Printed in Germany PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu 145

146 Product range HeatBloC Heating circuits and modular distribution manifolds DN 40/50 All HeatBloC s offer the following advantages: Preassembled group of fittings for heating circuits High flexibility during assembly modules can be combined as required Full port ball valve, gaskets of the spindle can be replaced during operation Connections Flange connection DN 40/PN 6 or DN 50/PN6 as slip-on flange and 1½" / 2" internal thread incl. gaskets and screws for the installation on PAW modular distribution manifolds With PAW mounting equipment, the HeatBloCs can be installed on wall brackets. Hand lever at the ball valve easy handling from the front, even when the insulation is closed, visible closing position EnEV conform functional insulation made of durable elastic EPP, complete insulation of valves and fittings, ventilation opening to cool the pump Free access to the pump head by simply removing the front insulation shell Check valve in the return pipe can be opened, 200 mm wc, spring-loaded, thus suited for horizontal and overhead installation DN 40 Flow on the right = standard The HeatBloC s can be delivered with flow on the left against additional charge. Flow and return line can be changed on site, also for heating circuits with mixing valve Fill and drain valve for flushing, filling and draining, integrated in the ball valve Full metal thermometers can be pulled off, with immersion sleeve integrated in the ball valve PAW heating pumps with high-efficiency (ECM) technology fitted with 2 m cable, completely premounted, integrated in the insulation, pressure tested, with serial number, perfectly designed system, pump characteristics, EuP/ErP READY Pump can be isolated, so that it can be replaced without draining You will find the complete mounting equipment for the modular system DN 40 at page 151, for the modular system DN 50 at page /2017 Printed in Germany PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu

147 Product range HeatBloC Heating circuits and modular distribution manifolds DN 40/50 - Types K31 - DN 40 (1½") direct / unmixed K32 - DN 40 (1½") with 3-way mixing valve Modular distribution manifold DN 40 (1½") 2-fold, 3-fold, 4-fold up to 150 kw* up to 125 kw* up to 250 kw* K31 - DN 50 (2") direct / unmixed K32 - DN 50 (2") with 3-way mixing valve Modular distribution manifold DN 50 (2") 2-fold, 3-fold, 4-fold DN 40 up to 250 kw* up to 230 kw* up to 400 kw* *Temperature difference = 20 K 01/2017 Printed in Germany PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu 147

148 HeatBloC K31 - DN 40 (1½") direct / unmixed Application range for boiler charging, for modulating temperature heating systems Recommended range of application up to 150 kw 20 K up to 6500 l/h Operating data Max. pressure 6 bars Max. operating temperature 110 C Kvs value 28.3 DN 40 Technical data Dimensions Nominal diameter DN 40 (1½") Connection generator Flange DN 40 / PN 6 Connection consumer 1½" int. thread (1) Height 610 mm (2) Installation length 560 mm (3) Centre distance 160 mm (4) Width 320 mm Materials Valves and fittings Brass Gaskets EPDM / NBR / AFM34 Insulation EPP Differential pressure diagram HeatBloC K31 - DN 40 (1½") EEI* incl. Item no. / piece Wilo-Yonos PARA HF 30/ < WY10 - Wilo-Stratos PARA 30/1-12 < WH12 - Wilo-Yonos PARA HF 40/0.5-8 < WY8 - Wilo-Yonos PARA HF 40/ < WY12 - Grundfos Magna < GL10 - Grundfos Magna F < GL12 - Grundfos Magna F < GH12 - for pumps with flange DN 40/PN 6 x 250 mm Prices excl. VAT 01/2017 Printed in Germany with pump without pump with actuator *Energy Efficiency Index PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu

149 HeatBloC K32 - DN 40 (1½") with 3-way mixing valve Application range for heating systems controlled by a mixing valve Recommended range of application up to 125 kw 20 K up to 5400 l/h Operating data Max. pressure 6 bars Max. operating temperature 110 C Kvs value 17.7 Technical data Dimensions Nominal diameter DN 40 (1½") Connection generator Flange DN 40 / PN 6 Connection consumer 1½" int. thread (1) Height 610 mm (2) Installation length 560 mm (3) Centre distance 160 mm (4) Width 320 mm Materials Valves and fittings Brass Gaskets EPDM / NBR / AFM34 Insulation EPP Differential pressure diagram HeatBloC K32 - DN 40 (1½") EEI* incl. Item no. / piece DN 40 Wilo-Yonos PARA HF 30/ < MWY10 - Wilo-Stratos PARA 30/1-12 < MWH12 - Wilo-Yonos PARA HF 40/0.5-8 < MWY8 - Wilo-Yonos PARA HF 40/ < MWY12 - Grundfos Magna < MGL10 - Grundfos Magna F < MGL12 - Grundfos Magna F < MGH12 - for pumps with flange DN 40/PN 6 x 250 mm 41221M - Extra charge for assembly with flow on the left per HeatBloC (no discount possible) Prices excl. VAT 01/2017 Printed in Germany with pump without pump with actuator *Energy Efficiency Index PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu 149

150 Modular distribution manifold - DN 40 (1½") for the standard and MC series Application range modular design for outputs up to 250 kw (for each boiler connection) at a temperature difference of 20 K Operating data Max. pressure 6 bars Max. operating temperature 110 C Kvs value 32.8 DN 40 Technical data Dimensions Nominal diameter DN 40 (1½") Connection generator Flange DN 50 / PN 6, flow at the side, return to the bottom, others sealed with 2" plug Connection consumer Flange DN 40 / PN 6 (on top) Connection on the side Installation height Height insulation 1" internal thread, sealed with plug, for safety group and expansion tank 179 mm 190 mm Centre distance 160 mm Materials Valves and fittings Gaskets Insulation Brass EPDM / NBR EPP shells Differential pressure diagram Modular distribution manifold - DN 40 (1½") Item no. / piece 2-fold Number of connections for HeatBloCs = 2 Width = 740 mm 3-fold Number of connections for HeatBloCs = 3 Width = 1060 mm 4-fold Number of connections for HeatBloCs = 4 Width = 1380 mm Prices excl. VAT 01/2017 Printed in Germany PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu

151 Equipment for modular system DN 40 Illustration Item no. / piece Wall bracket set for modular distribution manifold DN Parts: 2 wall brackets (steel, zinced), 4 wall plugs, 4 screws, 2 fixing screws for distribution manifold on the wall bracket Wall distance possible: A = 230 mm Wall bracket for HeatBloC DN Parts: Wall bracket (steel, zinced), 2 gaskets, mounting equipment Wall distance possible: A = 230 mm Floor bracket set for modular distribution manifold DN 40/DN Parts: 2 floor brackets (steel, zinced), 4 wall plugs, 4 screws, 2 fixing screws to fix the distribution manifold onto the floor brackets Adjustable hight: mm, for shortening simply cut off Extension module DN for the extension of already existing PAW HeatBloC systems, with insulation The installation may only be made by qualified experts! A = 160 mm, H = 170 mm, L = 320 mm Set reducer flanges DN 40 - DN Reducing flanges made of brass for connecting a DN 32 pump in the DN 40 HeatBloC or for mounting a DN 32 HeatBloC on a DN 40 modular distribution manifold. One side DN 40 flange with PN 6, other side flange for 2" flat sealing union nut. Reduction of the centre distance from 160 mm to 125 mm, installation height 35 mm each. Conversion kit for low-loss header DN for conversion into a distribution manifold with integrated hydraulic separator (low-loss header). Consisting of: 1 distance ring for a resistance-free connection of flow and return chamber, incl. screws and o-rings. Blind flange DN 40 / PN PN 6, as per DIN 2527, with 1 gasket, 4 screws and 4 nuts Screwed flange DN 40 / PN 6 on 1½" internal thread Screwed flange DN 50 / PN 6 on 2" internal thread PN 6, as per DIN 2565, steel, black DN 40 Weld neck flange DN 40 / PN Weld neck flange DN 50 / PN PN 6, as per DIN 2631, steel, black PAW actuator SR10-10 Nm 230 V Change-over switch for manual / automatic operation, simple assembly and disassembly thanks to the patented PAW snap-in mechanism, with 1.5 m cable and mounting set for halting assembly on the PAW mixing valve, for weather-compensated control, due to the removable scale it is suited for flow on the right or left side Technical data Electrical connection: Input power: Torque: Setting time for 90 : 230 V / 50 Hz 3.5 W 10 Nm 140 s Prices excl. VAT 01/2017 Printed in Germany PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu 151

152 HeatBloC K31 - DN 50 (2") direct / unmixed Application range for modulating temperature heating systems Recommended range of application up to 250 kw 20 K up to l/h Operating data Max. pressure 6 bars Max. operating temperature 110 C Kvs value 31.2 Technical data Dimensions Nominal diameter DN 50 (2") Connection generator Flange DN 50 / PN 6 Connection consumer 2" internal thread (1) Height 660 mm (2) Installation length 630 mm (3) Centre distance 180 mm (4) Width 360 mm Materials Valves and fittings Brass Gaskets EPDM / NBR / AFM34 Insulation EPP Differential pressure diagram HeatBloC K31 - DN 50 (2") EEI* incl. Item no. / piece DN 50 Wilo-Stratos 50/1-12 < WS12 - Wilo-Yonos PARA HF 50/0.5-9 < WY9 - Grundfos Magna F < GL12 - Grundfos Magna F < GH12 - for pumps with flange DN 50/PN 6 x 280 mm Prices excl. VAT 01/2017 Printed in Germany with pump without pump with actuator *Energy Efficiency Index PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu

153 HeatBloC K32 - DN 50 (2") with 3-way mixing valve Application range for heating systems controlled by a mixing valve Recommended range of application up to 230 kw 20 K up to 9980 l/h Operating data Max. pressure 6 bars Max. operating temperature 110 C Kvs value 25.7 Technical data Dimensions Nominal diameter DN 50 (2") Connection generator Flange DN 50 / PN 6 Connection consumer 2" internal thread (1) Height 660 mm (2) Installation length 630 mm (3) Centre distance 180 mm (4) Width 360 mm Materials Valves and fittings Brass Gaskets EPDM / NBR / AFM34 Insulation EPP Differential pressure diagram HeatBloC K32 - DN 50 (2") EEI* incl. Item no. / piece Wilo-Stratos 50/1-12 < MWS12 - Wilo-Yonos PARA HF 50/0.5-9 < MWY9 - Grundfos Magna F < MGL12 - Grundfos Magna F < MGH12 - for pumps with flange DN 50/PN 6 x 280 mm 51221M - Extra charge for assembly with flow on the left per HeatBloC (no discount possible) DN 50 Prices excl. VAT 01/2017 Printed in Germany with pump without pump with actuator *Energy Efficiency Index PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu 153

154 Modular distribution manifold - DN 50 (2") for the standard and MC series Application range modular design for outputs up to 400 kw (for each boiler connection) at a temperature difference of 20 K Operating data Max. pressure 6 bars Max. operating temperature 110 C Kvs value 48.9 DN 50 Technical data Dimensions Nominal diameter DN 50 (2") Connection generator Flange DN 65 / PN 6, flow at the side, return to the bottom, others sealed with 2½" plug Connection consumer Flange DN 50/PN 6 (on top) Connection on the side Installation height Height insulation 1¼" internal thread, sealed with plug, for safety group and expansion tank 225 mm 220 mm Centre distance 180 mm Materials Valves and fittings Gaskets Insulation Brass EPDM / NBR EPP shells Differential pressure diagram Modular distribution manifold - DN 50 (2") Item no. / piece 2-fold Number of connections for HeatBloCs = 2 Width = 840 mm 3-fold Number of connections for HeatBloCs = 3 Width = 1200 mm 4-fold Number of connections for HeatBloCs = 4 Width = 1560 mm Prices excl. VAT 01/2017 Printed in Germany PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu

155 Equipment for modular system DN 50 Illustration Item no. / piece Floor bracket set for modular distribution manifold DN 40/DN Parts: 2 floor brackets (steel, zinced), 4 wall plugs, 4 screws, 2 fixing screws to fix the distribution manifold onto the floor brackets Adjustable hight: mm, for shortening simply cut off Extension module DN for the extension of already existing PAW HeatBloC systems, with insulation The installation may only be made by qualified experts! A = 180 mm, H = 225 mm, L = 360 mm Conversion kit for low-loss header DN for conversion into a distribution manifold with integrated hydraulic separator (low-loss header). Consisting of: 1 distance ring for a resistance-free connection of flow and return chamber, incl. screws and o-rings. Set reducer flanges DN 50 - DN reducing flanges made of zinced steel for connecting a DN 40 HeatBloC on a DN 50 modular distribution manifold. For the assembly of a DN 40 pump, installation length 250 mm, in a DN 50 HeatBloC. One side DN 50 flange (PN 6), other side DN 40 flange (PN 6). Reduction of the centre distance from 180 mm to 160 mm, with seals and screws, installation height = 13 mm Use only with slip-on flanges! Set reducer flanges DN 50 - DN reducing flanges made of steel, zinced/brass for connecting a DN 32 HeatBloC on a DN 50 modular distribution manifold. One side DN 50 flange with PN 6, other side DN 32-1¼". Reduction of the centre distance from 180 mm to 125 mm, with seals and screws for connection to DN 50. Installation height = 48 mm Blind flange DN 50 / PN PN 6, as per DIN 2527, with 1 gasket, 4 screws and 4 nuts Screwed flange DN 50 / PN 6 on 2" internal thread Screwed flange DN 65 / PN 6 on 2½" internal thread PN 6, as per DIN 2565, steel, black Weld neck flange DN 50 / PN Weld neck flange DN 65 / PN PN 6, as per DIN 2631, steel, black DN 50 PAW actuator SR10-10 Nm 230 V Change-over switch for manual / automatic operation, simple assembly and disassembly thanks to the patented PAW snap-in mechanism, with 1.5 m cable and mounting set for halting assembly on the PAW mixing valve, for weather-compensated control, due to the removable scale it is suited for flow on the right or left side Technical data Electrical connection: Input power: Torque: Setting time for 90 : 230 V / 50 Hz 3.5 W 10 Nm 140 s Prices excl. VAT 01/2017 Printed in Germany PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu 155

156

157 Return flow temperature maintenance Catalogue 01/2017 Valves and fittings for the use in hot water heating systems Valid for the UK

158 Return flow temperature maintenance with thermal control valve DN 20 (¾") / DN 25 (1") Application range Heating installations with return flow temperature maintenance For solid fuel boilers, wood-fired and stove heating systems The pump sets for the return flow temperature maintenance are groups of fittings for pumps that can be isolated. They consist of: High-efficiency pump Control valve with an opening temperature of 50 C, 55 C or 60 C 1 thermometer ball valve with a red dial thermometer integrated in the handle, can be pulled off 2 thermometer ball valves with a blue dial thermometer integrated in the handle, can be pulled off Connections DN 20: ¾" int. thread Connections DN 25: 1" int. thread Thermal control valve with automatic bypass 1. The thermal valve shuts off the connection to the buffer tank as long as the water in the boiler circuit is colder than the opening temperature of the thermal control valve. The pump circulates the water via the bypass, the small quantity of water in the boiler circuit can now heat up quickly. 2. When the boiler circuit reaches the opening temperature of the control valve, the valve reduces the bypass flow rate and opens the buffer tank circuit. The cold water from the buffer tank return is mixed with the hot boiler circuit water in the control valve. This leads to an increase of the return temperature in the boiler circuit to the desired level and avoids condensation in the boiler. 3. When the buffer tank return temperature is higher than the opening temperature, the control valve completely shuts off the bypass. Thus, the water from the buffer tank flows directly into the boiler circuit. Please note: If the boiler output is controlled by the boiler temperature, the boiler must heat up 20 K above the opening temperature of the return flow temperature maintenance. Otherwise, the boiler might reduce the output even before the thermal control valve is completely open. Mounting versions 1 and 2: Temperatures t BY = bypass t KR = boiler return t PR = return of the buffer tank t FIX = opening temperature Separate assembly of the group of fittings in the flow and return. This version permits an easy isolation of the heat generator without further shut-off valves. Consider the position of the safety group before mounting. Additionally required: Heating fittings 1 x gasket: DN 20 item no. 2057, DN 25 item no x screw-in fitting: DN 20 item no. 2053, DN 25 item no x pump fitting: DN 20 item no. 2049, DN 25 item no /2017 Printed in Germany PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu

159 Return flow temperature maintenance with thermal control valve DN 20 (¾") / DN 25 (1") Thermometer ball valve one-piece housing made of brass spindle can be replaced under pressure temperature measuring by means of the spindle in the fluid High-efficiency pump fitted with 2 m cable with serial number ErP and EuP READY Thermometer ball valve high Kvs value 3 ball valves per return flow temperature maintenance allow to shut off the group no draining necessary for service work at the pump or at the control valve Thermal control valve high Kvs value for an energy-saving use Immersion thermometer with handle, C Serial numbers of the return flow temperature maintenance and the pump reliable identification, fast service Mounting version 1 Mounting version 2 Heating fittings 01/2017 Printed in Germany PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu 159

160 Return flow temperature maintenance RHT with thermal control valve - DN 20 (¾") Application range heating systems with return flow temperature maintenance for solid fuel boilers, wood-fired and stove heating systems Recommended range of application up to 11 kw 10 K up to 950 l/h l/h Operating data Max. pressure 6 bars Max. operating temperature 110 C Kvs value 4.7 Technical data Dimensions Nominal diameter Connection generator Connection consumer Installation height Installation length Equipment DN 20 (¾") ¾" internal thread ¾" internal thread 112 mm 336 mm red and blue dial thermometer integrated into black plastic handles, measuring range: C Materials Valves and fittings Gaskets Brass AFM34 Differential pressure diagram RH50T-20 EEI* Item no. / piece Heating fittings Wilo-Yonos PARA RS 15/6-RKA < WY6 - Wilo-Stratos PICO 15/1-6 < WH6 - Opening temperature 50 C Grundfos UPM3 Auto L PP3 < GM6 - Grundfos Alpha < GH6 - for pumps with 1" external thread RH55T-20 EEI* Item no. / piece Wilo-Yonos PARA RS 15/6-RKA < WY6 - Wilo-Stratos PICO 15/1-6 < WH6 - Opening temperature 55 C Grundfos UPM3 Auto L PP3 < GM6 - Grundfos Alpha < GH6 - for pumps with 1" external thread RH60T-20 EEI* Item no. / piece Wilo-Yonos PARA RS 15/6-RKA < WY6 - Wilo-Stratos PICO 15/1-6 < WH6 - Opening temperature 60 C Grundfos UPM3 Auto L PP3 < GM6 - Grundfos Alpha < GH6 - for pumps with 1" external thread Prices excl. VAT 01/2017 Printed in Germany *Energy Efficiency Index PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu

161 Return flow temperature maintenance RHT - DN 20 (¾") Mounting example Mounting version 1 Mounting version 2 Accessories Item no. / piece Sealing for nut DN 20 (¾") asbestos-free Screw-in fitting DN 20 (¾") 1" ext. thread, flat sealing x ¾" int. thread Pump fitting DN 20 (¾") with union nut, insert fitting and gasket Cutting-ring compression fitting DN 20 (¾") d = 15 mm ¾" external thread, self-sealing with o-ring, with support sleeve, suitable for soft copper pipes. For temperatures up to 150 C Cutting-ring compression fitting DN 20 (¾") d = 18 mm ¾" external thread, self-sealing with o-ring, with support sleeve, suitable for soft copper pipes. For temperatures up to 150 C. Cutting-ring compression fitting DN 20 (¾") d = 22 mm ¾" external thread, self-sealing with o-ring, with support sleeve, suitable for soft copper pipes. For temperatures up to 150 C Heating fittings Prices excl. VAT 01/2017 Printed in Germany PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu 161

162 Return flow temperature maintenance RHT with thermal control valve - DN 25 (1") Application range heating systems with return flow temperature maintenance for solid fuel boilers, wood-fired and stove heating systems Recommended range of application up to 26 KW 10 K up to 2250 l/h l/h Operating data Max. pressure 6 bars Max. operating temperature 110 C Kvs value 7.2 Technical data Dimensions Nominal diameter Connection generator Connection consumer Installation height Installation length Equipment DN 25 (1") 1" internal thread 1" internal thread 128 mm 428 mm red and blue dial thermometer integrated into black plastic handles, measuring range: C Materials Valves and fittings Gaskets Brass AFM34 Differential pressure diagram RH50T-25 EEI* Item no. / piece Heating fittings Wilo-Yonos PARA RS 25/6-RKA < WY6 - Wilo-Stratos PICO 25/1-6 < WH6 - Opening temperature 50 C Grundfos UPM3 Auto L PP3 < GM6 - Grundfos Alpha < GH6 - for pumps with 1½" external thread RH55T-25 EEI* Item no. / piece Wilo-Yonos PARA RS 25/6-RKA < WY6 - Wilo-Stratos PICO 25/1-6 < WH6 - Opening temperature 55 C Grundfos UPM3 Auto L PP3 < GM6 - Grundfos Alpha < GH6 - for pumps with 1½" external thread RH60T-25 EEI* Item no. / piece Wilo-Yonos PARA RS 25/6-RKA < WY6 - Wilo-Stratos PICO 25/1-6 < WH6 - Opening temperature 60 C Grundfos UPM3 Auto L PP3 < GM6 - Grundfos Alpha < GH6 - for pumps with 1½" external thread Prices excl. VAT 01/2017 Printed in Germany *Energy Efficiency Index PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu

163 Return flow temperature maintenance RHT - DN 25 (1") Mounting example Mounting version 1 Mounting version 2 Accessories Item no. / piece Sealing for nut DN 25 (1") asbestos-free Screw-in fitting DN 25 (1") 1½" ext. thread, flat sealing x 1" int. thread Pump fitting DN 25 (1") with union nut, insert fitting and gasket Cutting-ring compression fitting DN 25 (1") d = 15 mm 1" external thread, self-sealing with o-ring, with support sleeve, suitable for soft copper pipes. For temperatures up to 150 C Cutting-ring compression fitting DN 25 (1") d = 18 mm 1" external thread, self-sealing with o-ring, with support sleeve, suitable for soft copper pipes. For temperatures up to 150 C. Cutting-ring compression fitting DN 25 (1") d = 22 mm 1" external thread, self-sealing with o-ring, with support sleeve, suitable for soft copper pipes. For temperatures up to 150 C Heating fittings Prices excl. VAT 01/2017 Printed in Germany PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu 163

164 Return flow temperature maintenance with actuator DN 20 (¾") - DN 50 (2") DN 20 (¾") Application range Heating installations with return flow temperature maintenance for solid fuel boilers, wood-fired and stove heating systems Product description: The return flow temperature maintenance with actuator is a premounted group of fittings for heating circuits. The pump and the mixing valve can be isolated by means of the ball valves. An easy maintenance can thus be carried out without draining the heating circuit. DN 25 (1") DN 32 (1¼") Description of function: The pump set prevents the temperature in the boiler from falling under the dew point, thus reducing contamination of the boiler. The pump set is mounted between the buffer tank and the boiler. The actuator is controlled by an external controller. The actuator opens the 3-way valve only when the boiler circuit has reached the opening temperature set. By means of the mixing valve, the return flow temperature in the boiler is kept at a constant level and the maximum amount of energy for the storage tank charging is provided. DN 40 (1½") DN 50 (2") Heating fittings /2017 Printed in Germany PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu

165 Return flow temperature maintenance with actuator DN 20 (¾") - DN 50 (2") Pump ball valve one-piece housing made of brass spindle can be replaced under pressure High-efficiency pump fitted with 2 m cable with serial number ErP and EuP READY Pump ball valve high Kvs value 3 ball valves per return flow temperature maintenance allow to shut off the group no draining necessary for service work at the pump or at the mixing valve Actuator 2 Nm / 230 V (DN 20) 5 Nm / 230 V (DN 25 - DN 50) 3-point-control can be used as mixing valve or as switch valve, manual operation possible Immersion thermometer with handle, C Serial numbers of the return flow temperature maintenance and the pump reliable identification, fast service Mixing valve / switch valve high Kvs value for an energy-saving use Mounting example return flow temperature maintenance with actuator DN 25 Heating fittings 01/2017 Printed in Germany PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu 165

166 Return flow temperature maintenance with actuator Technical data Application range for heating systems with return flow temperature maintenance for solid fuel boilers, wood-fired and stove heating systems Technical data DN 20 DN 25 DN 32 DN 40 DN 50 Dimensions (1) Installation height (2) Installation length (3) Insulation Connections Operating data Max. pressure Max. operating temperature 134 mm 187 mm 217 mm 266 mm 296 mm 359 mm 437 mm 497 mm 735 mm 792 mm / 520 x 236 x 131 mm 520 x 236 x 131 mm / / ¾" internal thread 1" internal thread 1¼" internal thread 1½" internal thread 2" internal thread Kvs value [m³/h] Materials Valves and fittings Gaskets Actuator 6 bars 110 C Brass EPDM / NBR Electrical data 230 V / 50 Hz 230 V / 50 Hz Power consumption 1 W 2.5 W Torque 2 Nm 5 Nm Setting time s 140 s Pump sets for return flow temperature maintenance - DN 20 (¾") Differential pressure diagram Pump sets for return flow temperature maintenance - DN 25 (1") / DN 32 (1¼") Pump sets for return flow temperature maintenance - DN 40 (1½") / DN 50 (2") Heating fittings /2017 Printed in Germany PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu

167 Return flow temperature maintenance with actuator Dimensions, order data Dimensions Pump sets for return flow temperature maintenance - DN 25 (1") Pump sets for return flow temperature maintenance - DN 50 (2") Pump sets for return flow temperature maintenance - DN 20 (¾") EEI* Item no. / piece Wilo-Yonos PARA RS 15/6-RKA < WY6 - Wilo-Stratos PICO 15/1-6 < WH6 - Grundfos UPM3 Auto L PP3 < GM6 - Grundfos Alpha < GH6 - Pump sets for return flow temperature maintenance - DN 25 (1") with insulation EEI* Item no. / piece Wilo-Yonos PARA RS 25/6-RKA < WY6 - Wilo-Yonos PARA RS 25/7.5-RKA < WY8 - Wilo-Stratos PICO 25/1-6 < WH6 - Grundfos UPM3 Auto L PP3 < GM6 - Grundfos Alpha < GH6 - Grundfos UPML Auto < GL9 - Pump sets for return flow temperature maintenance - DN 32 (1¼") with insulation EEI* Item no. / piece Wilo-Yonos PARA RS 30/6-RKA < WY6 - Wilo-Yonos PARA HF 30/ < WY10 - Grundfos UPM3 Auto L PP3 < GM6 - Grundfos Alpha < GH6 - Pump sets for return flow temperature maintenance - DN 40 (1½") EEI* Item no. / piece Wilo-Yonos PARA HF 40/ < WY12 - Wilo-Stratos PARA 30/1-12 < WH12 - Grundfos Magna < GL10 - Grundfos Magna F < GL12 - Pump sets for return flow temperature maintenance - DN 50 (2") EEI* Item no. / piece Wilo-Yonos PARA HF 50/0.5-9 < WY9 - Wilo-Stratos PARA 30/1-12 < WH12 - Grundfos Magna < GL10 - Grundfos Magna F < GL12 - Heating fittings Prices excl. VAT 01/2017 Printed in Germany *Energy Efficiency Index PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu 167

168 Pump sets Illustration Item no. / piece Charging pump set K1 Pressure side: - PAW pump ball valve, with red butterfly handle - flow check valve, can be opened manually - automatic air passage - with 2 nuts and 2 gaskets for a pump DN 25 (without pump) Suction side: - PAW pump ball valve, with red butterfly handle Nominal diameter PAW flange Internal thread (with nut) DN 25 (1") 1" 1" DN 32 (1¼") 1¼" 1¼" Flow set K2 pump can be isolated Pressure side: - PAW multivalve, with red butterfly handle - check valve, can be opened manually - automatic air passage - with 2 nuts and gaskets for a pump DN 25 (without pump, without dial thermometer) Suction side: - PAW pump ball valve, with red butterfly handle Thermometer available as accessory, item number (red) Nominal diameter PAW flange Internal thread (with nut) DN 25 (1") 1" 1" DN 32 (1¼") 1¼" 1¼" DN 32 (1¼") 1" 1¼" Flow set K2 with insulation Design as described above, but additionally with: - two EPP shells, temperature-resistant, up to 130 C - dial thermometer with red scale Nominal diameter PAW flange Internal thread (with nut) DN 25 (1") 1" 1" 2705.ISO - Return set K3 consisting of: PAW multivalve with red butterfly handle and thread connection (without dial thermometer) Heating fittings Thermometer available as accessory, item number (blue) Nominal diameter PAW flange Internal thread (with nut) DN 25 (1") 1" 1" DN 32 (1¼") 1¼" 1¼" DN 25/32 (1"/1¼") 1" 1¼" Prices excl. VAT 01/2017 Printed in Germany PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu

169 Illustration Item no. / piece Pump set K5 pump can be isolated Pressure side: - PAW multivalve, with red butterfly handle - check valve, can be opened manually - automatic air passage - with 2 nuts and gaskets for a pump (without pump, without dial thermometer) Suction side: - PAW pump ball valve, with red butterfly handle Return: - PAW multivalve, with red butterfly handle - thread connection Thermometers available as accessory, item numbers (red), (blue) Nominal diameter PAW flange Internal thread (without nut) DN 25 (1") 1" 1" DN 32 (1¼") 1¼" 1¼" DN 25/32 (1"/1¼") 1" 1¼" Bypass set K7 can be completely isolated Pressure side: - PAW multivalve with red butterfly handle - check valve, can be opened - automatic air passage - with 2 nuts and 2 gaskets for a pump DN 25 (without pump, without dial thermometer) Suction side: - PAW pump ball valve with red butterfly handle Return: - PAW multivalve with red butterfly handle - thread connection Bypass: - differential pressure overflow valve ¾" with scale and thread connection - zinced bypass pipe with elbow gland A min = 80 mm A max = 200 mm for 1": H = 360 mm for 1¼": H = 395 mm Thermometers available as accessory, item numbers (red), (blue) Nominal diameter PAW flange Internal thread (with nut) DN 25 (1") 1" 1" DN 32 (1¼") 1¼" 1¼" DN 25/32 (1"/1¼") 1" 1¼" Air heater connection set K4LE to connect heat exchangers/air heaters Flow: - PAW ball valve, with red butterfly handle - automatic air vent - thread connection Return: - PAW multivalve, with red butterfly handle - fill and drain valve - thread connection Nominal diameter PAW flange Internal thread (with nut) DN 25 (1") 1" 1" DN 32 (1¼") 1¼" 1¼" Heating fittings Prices excl. VAT 01/2017 Printed in Germany PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu 169

170 Illustration Item no. / piece Flow set TK2 Pressure side: - thermometer ball valve with red scale thermometer integrated in the handle (d = 50 mm) - integrated check valve, can be opened manually - DN 25 and DN 32: connection to the left with ½" internal thread for overflow valve or sensor, plugged Suction side: - DN 20: pump ball valve, ¾", key-actuated - DN 25 and DN 32: pump ball valve with butterfly handle Delivery with 2 nuts and 2 gaskets for a pump (without pump) DN 20 Nominal diameter Internal thread (G) Internal thread DN 20 (¾") ¾" ¾" DN 25 (1") 1" 1" DN 32 (1¼") 1¼" 1¼" DN 25/32 Return set TK3 consisting of: - thermometer valve with blue scale dial thermometer integrated in the handle (d = 50 mm) - DN 25 and DN 32: connection to the left with ½" internal thread for overflow valve or sensor, plugged Delivery with thread connection Nominal diameter PAW flange Internal thread (with nut) DN 20 (¾") ¾" ¾" DN 25 (1") 1" 1" DN 32 (1¼") 1¼" 1¼" Overflow set Overflow valve with scale, bypass pipe, elbow gland, completely self-sealing. Centre distance A = length, see table For larger distances you will have to install a copper pipe 22 in the necessary length on site and 2851: with screw connection 2 x ½" external thread 2853: with screw connection 2 x ¾", flat-sealing, suitable for foreign products Nominal diameter External thread (R) Centre distance (A) DN 20 (¾") ½" 200 mm DN 20 (¾") ½" 125 mm DN 20 (¾") ¾" 200 mm Heating fittings Dial thermometer Measuring range C, immersion shaft 25 mm, with self-sealing immersion sleeve, d = 50 mm Dial thermometer d = 50 mm with red scale Dial thermometer d = 50 mm with blue scale Prices excl. VAT 01/2017 Printed in Germany PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu

171 Illustration Item no. / piece Pump set TK5 Pressure side: - thermometer valve with red scale, dial thermometer integrated in handle (d = 50 mm), can be pulled off - integrated check valve, can be opened manually - DN 25 and DN 32: connection to the left, ½" internal thread for overflow valve or sensor, plugged Suction side: - DN 20: pump ball valve, key-actuated - DN 25 and DN 32: pump ball valve with butterfly handle DN 20 Return: - thermometer valve with blue scale dial thermometer integrated in the handle (d = 50 mm), can be pulled off - DN 25 and DN 32: connection to the right, ½" internal thread for overflow valve or sensor, plugged - thread connection Delivery with 2 nuts and 2 gaskets for a pump (without pump) Nominal diameter Internal thread (G) Internal thread DN 20 (¾") ¾" ¾" DN 25 (1") 1" 1" DN 32 (1¼") 1¼" 1¼" DN 25/32 Pump set TK7 Pressure side: - thermometer valve with red scale dial thermometer integrated in handle (d = 50 mm), can be pulled off - integrated check valve, can be opened manually - DN 25 and DN 32: connection to the left with ½" internal thread for overflow valve or sensor, plugged Suction side: - DN 20: pump ball valve, key-actuated - DN 25 and DN 32: pump ball valve with butterfly handle DN 20 Return: - thermometer valve with blue scale dial thermometer integrated in the handle (d = 50 mm), can be pulled off - DN 25 and DN 32: connection to the right, ½" internal thread for overflow valve - thread connection - differential pressure overflow valve ¾" with scale and thread connection - zinced bypass pipe for centre distances up to 200 mm, with elbow gland Delivery with 2 nuts and 2 gaskets for a pump (without pump) Nominal diameter Internal thread (G) Internal thread DN 20 (¾") ¾" ¾" DN 25 (1") 1" 1" DN 32 (1¼") 1¼" 1¼" DN 25/32 Heating fittings Prices excl. VAT 01/2017 Printed in Germany PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu 171

172 Mixing valve actuators and accessories Illustration Item no. / piece PAW actuator SR2-2 Nm 230 V PAW actuator SR2-2 Nm 24 V Easy assembly and disassembly thanks to the patented PAW snap-in mechanism, with 1.5 m cable and mounting set for halting assembly on the PAW mixing valve, for weather-compensated control, due to the removable scale it is suited for flow on the right or left side, change-over switch for manual / automatic operation Technical data Electrical connection: 230 V - 50 Hz (705013), 24 V - 50/60 HZ, DC 24 V (705015) Input power: 1 W (705013), 0.5 W (705015) Torque: min. 2 Nm Setting time for 90 : 105 s (705013), 100 s (705015) PAW actuator SR5-5 Nm 230 V Change-over switch for manual / automatic operation, simple assembly and disassembly thanks to the patented PAW snap-in mechanism, with 1.5 m cable and mounting set for halting assembly on the PAW mixing valve, for weather-compensated control, due to the removable scale it is suited for flow on the right or left side Technical data Electrical connection: Input power: Torque: Setting time for 90 : 230 V / 50 Hz 2.5 W 5 Nm 140 s PAW actuator SR10-10 Nm 230 V Change-over switch for manual / automatic operation, simple assembly and disassembly thanks to the patented PAW snap-in mechanism, with 1.5 m cable and mounting set for halting assembly on the PAW mixing valve, for weather-compensated control, due to the removable scale it is suited for flow on the right or left side Technical data Electrical connection: Input power: Torque: Setting time for 90 : 230 V / 50 Hz 3.5 W 10 Nm 140 s PAW actuator SR10 24/3P - 10 Nm 24 V Like PAW actuator SR10 (item no ), but: with electrical connection/supply voltage 24 VAC for control systems with 3-level-control Technical data Electrical connection: Input power: Torque: Setting time for 90 : 24 V/50 Hz 1.5 W 10 Nm 140 s PAW actuator SR10 24/ST - 10 Nm 24 V Like PAW actuator SR10 (item no ), but: with electrical connection/supply voltage 24 VAC/DC control voltage direct: 0(2)...10 VDC for continuous control systems with 0 10 V output Technical data Electrical connection: Input power: Torque: Setting time for 90 : 24 V/50 Hz 1.5 W 10 Nm 140 s Heating fittings 172 Prices excl. VAT 01/2017 Printed in Germany PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu

173 Illustration Item no. / piece Limit switch The limit switch is a micro switch. For the assembly in the actuators SR5 and SR10-24/3P. Accessory kit for Viessmann actuators Accessory kit for PAW actuators with 3-point suspension (Dekamatik and Vitotronic) to PAW mixing valves DN 20 - DN 50 with short shaft. Please consider the width of the actuator when mounting it to the HeatBloCs DN 20. Not to be mounted to separation systems TE3. Adapter set for mixing valve shaft Adapter piece to extend the shaft of PAW mixing valves, for the assembly of actuators of other manufacturers Heating fittings Prices excl. VAT 01/2017 Printed in Germany PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu 173

174 Heating fittings - Ball valves Illustration Item no. / piece Multivalve MK 2 x sleeves ½" (on the side) 1 x self-sealing blind plug ½" 1 x PAW flange (without nut) 1 x internal thread Material: brass, with red butterfly handle Nominal diameter PAW flange Internal thread Length (without nut) DN 25 (1") 1" 1" 94 mm DN 32 (1¼") 1¼" 1¼" 115 mm DN 25/32 (1"/1¼") 1" 1¼" 103 mm Multivalve with check valve MKS 2 x sleeves ½" (on the side) 1 x self-sealing blind plug ½" 1 x PAW flange (without nut) 1 x internal thread Material: Brass, with red butterfly handle With automatic air passage and check valve (can be opened) Nominal diameter PAW flange Internal thread Length (without nut) DN 25 (1") 1" 1" 94 mm DN 32 (1¼") 1¼" 1¼" 115 mm DN 25/32 (1"/1¼") 1" 1¼" 103 mm Pump ball valve PK 1 x PAW flange (without nut) 1 x internal thread Material: Brass, with red butterfly handle Nominal diameter PAW flange Internal thread Length (without nut) DN 25 (1") 1" 1" 78 mm DN 32 (1¼") 1¼" 1¼" 100 mm DN 25/32 (1"/1¼") 1" 1¼" 83 mm Ball stop PKS 1 x PAW flange (without nut) 1 x internal thread Material: Brass with red butterfly handle, with automatic air passage and check valve (can be opened) Nominal diameter PAW flange Internal thread Length (without nut) DN 25 (1") 1" 1" 78 mm DN 32 (1¼") 1¼" 1¼" 100 mm DN 25/32 (1"/1¼") 1" 1¼" 83 mm Pump ball valve PKA 1 x PAW flange (withut nut) 1 x external thread Material: Brass, with red butterfly handle Nominal diameter PAW flange External thread Length (without nut) DN 25 (1") 1" 1" 93 mm Heating fittings Pump ball valve PKAS 1 x PAW flange (without nut) 1 x external thread Material: Brass With red butterfly handle, with automatic air passage and check valve (can be opened) Nominal diameter PAW flange External thread Length (without nut) DN 25 (1") 1" 1" 93 mm Prices excl. VAT 01/2017 Printed in Germany PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu

175 Illustration Item no. / piece Pump ball valve PKV 1 x PAW flange (withut nut) 1 x external thread Material: Brass, with red butterfly handle Nominal diameter PAW flange External thread Length (without nut) DN 25 (1") 1" 1½" 80 mm DN 32 (1¼") 1¼" 2" 110 mm Pump ball valve PKVS 1 x PAW flange (without nut) 1 x external thread Material: Brass With red butterfly handle, with automatic air passage and check valve (can be opened) Nominal diameter PAW flange External thread Length (without nut) DN 25 (1") 1" 1½" 80 mm DN 32 (1¼") 1¼" 2" 110 mm Thermometer ball valve TK DN 20 (¾") 1 x PAW flange (without nut) 1 x internal thread Diameter thermometer = 50 mm Dial thermometer with blue scale in the handle, handle with thermometer can be pulled off Nominal diameter PAW flange Internal thread Length (without nut) DN 20 (¾") ¾" ¾" 66 mm Thermometer ball valve TK DN 25 (1"), DN 32 (1¼") 1 x PAW flange (without nut) 1 x internal thread 1 x sleeve (on the side) ½", for overflow valve 1 x self-sealing blind plug ½" Diameter thermometer = 50 mm Dial thermometer with blue scale in the handle, handle with thermometer can be pulled off Nominal diameter PAW flange Internal thread Length (without nut) DN 25 (1") 1" 1" 81 mm DN 32 (1¼") 1¼" 1¼" 104 mm Thermometer valve with check valve TKS DN 20 (¾") 1 x PAW flange (without nut) 1 x internal thread Diameter thermometer = 50 mm Dial thermometer with red scale in the handle, handle with thermometer can be pulled off, check valve 200 mm wc, can be opened Nominal diameter PAW flange Internal thread Length (without nut) DN 20 (¾") ¾" ¾" 65 mm Thermometer valve with check valve TKS 1 x PAW flange (without nut) 1 x internal thread 1 x sleeve (on the side) ½", for overflow valve or immersion sleeve/sensor connection 1 x self-sealing blind plug ½" Diameter thermometer = 50 mm Dial thermometer with red scale in the handle, handle with thermometer can be pulled off, check valve 200 mm wc, can be opened Nominal diameter PAW flange Internal thread Length (without nut) DN 25 (1") 1" 1" 81 mm DN 32 (1¼") 1¼" 1¼" 104 mm Heating fittings Prices excl. VAT 01/2017 Printed in Germany PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu 175

176 Illustration Item no. / piece Ball valve DN 25 (1") 1 x external thread 1 x nut Key actuated, ideal to shut off armoured hoses as it is flat-sealing Nominal diameter [ ] External thread Length DN 25 (1") [ ] 1" 50 mm Elbow ball valve DN 25 (1") 1 x external thread 1 x nut Key actuated, ideal to shut off armoured hoses as it is flat-sealing Nominal diameter [ ] External thread Length DN 25 (1") [ ] 1" 87 mm Full port ball valve KMA 1 x external thread 1 x internal thread Material: Brass, nickel-plated Max. operating temperature: 100 C with red butterfly handle Nominal diameter External thread Internal thread Length DN 12 3/8'' 3/8'' 47 mm DN 15 (½") ½" ½" 48.5 mm DN 20 (¾") ¾" ¾" 64 mm DN 25 (1") 1" 1" 66 mm Full port ball valve KMM 2 x internal thread Material: Brass, nickel-plated Max. operating temperature: 100 C Nominal diameter Internal thread Internal thread Length DN 10 (3/8") ¼" ¼" 44 mm DN 12 3/8'' 3/8'' 48 mm DN 15 (½") ½" ½" 48 mm DN 20 (¾") ¾" ¾" 65 mm DN 25 (1") 1" 1" 67 mm DN 32 (1¼") 1¼" 1¼" 81 mm DN 40 (1½") 1½" 1½" 93 mm DN 50 (2") 2" 2" 113 mm DN 80 (3") 3" 3" 177 mm Full port ball valve with connection KMV 1 x external thread 1 x internal thread Material: Brass, nickel-plated With red butterfly handle Max. operating temperature: 100 C Nominal diameter External thread Internal thread Length DN 15 (½") ½" ½" 73.5 mm DN 20 (¾") ¾" ¾" 88 mm DN 25 (1") 1" 1" 98 mm DN 32 (1¼") 1¼" 1¼" 113 mm Heating fittings Handle extension for ball valve Function: for thick insulation of the ball valve Material: Brass, chromed Can be replaced under pressure when the ball valve is closed. Available for: MK, PK, TK, KMM, KMV. Please state the type of ball valve and the nominal diameter when ordering! Nominal diameter [ ] [ ] Length DN 25/32 (1"/1¼") [ ] [ ][ ] 88 mm DN 40/50 (1½"/2") [ ] [ ][ ] 95 mm Prices excl. VAT 01/2017 Printed in Germany PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu

177 Heating fittings - Screw connections Illustration Item no. / piece Thread connection for PAW flange Thread connection for PAW flange with union nut, screw-in fitting and gasket Nominal diameter Internal thread Length DN 20 (¾") ¾" 32 mm DN 25 (1") 1" 26 mm DN 32 (1¼") 1¼" 33 mm Pump fitting DN 20 (¾") with union nut, insert fitting and gasket Nominal diameter Internal thread Length DN 20 (¾") ¾" 30 mm Pump fitting DN 25 (1") and DN 32 (1¼") with union nut, insert fitting and gasket Nominal diameter Internal thread Length DN 25 (1") 1" 28 mm DN 32 (1¼") 1¼" 31 mm Screw-in fitting Nominal diameter External thread Internal thread (G) Length DN 20 (¾") 1" ¾" 30mm DN 25 (1") 1½" 1" 26mm DN 32 (1¼") 2" 1¼" 33 mm Insert fitting Nominal diameter Internal thread Length DN 25 (1") 1" 26 mm DN 32 (1¼") 1¼" 29mm Union nut Brass, to screw insertion pieces for soldering below a distribution manifold Nominal diameter Internal thread (G) Length DN 20 (¾") 1" 15 mm DN 25 (1") 1½" 20 mm DN 32 (1¼") 2" 22 mm Sealing for nut asbestos-free Nominal diameter Length DN 20 (¾") 2 mm DN 25 (1") 2 mm DN 32 (1¼") 2 mm Heating fittings Prices excl. VAT 01/2017 Printed in Germany PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu 177

178 Heating fittings - Check valves Illustration Item no. / piece Check valve SBA DN 25 (1") Check valve, can be opened, with union nut, gasket and PAW flange for warm water central heating PN 10, 120 C, suited for horizontal and vertical installation, to be screwed directly to the pump. Opening pressure 200 mm wc. Nominal diameter PAW flange External thread Length (with nut) DN 25 (1") 1" 1½" 48 mm Check valve with automatic air passage SBA DN 25 (1") Check valve, can be opened, with union nut, gasket and PAW flange for warm water central heating PN 10, 120 C, suited for horizontal and vertical installation, to be screwed directly to the pump. Opening pressure 200 mm wc. Nominal diameter PAW flange External thread Length (with nut) DN 25 (1") 1" 1½" 48mm Check valve SBM Check valve, can be opened, with gasket for warm water central heating PN 10, 120 C, suited for horizontal and vertical installation, to be screwed directly to the pump. Opening pressure 200 mm wc. Nominal diameter Internal thread External thread Length DN 20 (¾") 1" 1" 26 mm DN 20 (¾") 1¼" 1¼" 26 mm DN 25 (1") 1½" 1½" 26mm DN 25 (1") 1½" 1½" 38 mm DN 32 (1¼") 2" 2" 39mm Check valve with automatic air passage SBM Check valve, can be opened, with gasket for warm water central heating PN 10, 120 C, suited for horizontal and vertical installation, to be screwed directly to the pump. Opening pressure 200 mm wc. Nominal diameter Internal thread External thread Length DN 20 (¾") 1" 1" 26 mm DN 25 (1") 1½" 1½" 26 mm DN 25 (1") 1½" 1½" 38 mm DN 32 (1¼") 2" 2" 39 mm Check valve SBE-IG Check valve, can be opened, with internal thread and PAW flange for warm water central heating PN 10, 120 C, suited for horizontal and vertical installation. Can also be used as non-return valve. To be screwed directly to the pump. Opening pressure 200 mm wc. Nominal diameter PAW flange Internal thread Length (without nut) DN 20 (¾") 1" ¾" 45mm DN 25 (1") 1" 1" 45 mm DN 25 (1") 1" 1" 57 mm Heating fittings Check valve with air passage SBE-IG Check valve, can be opened, with automatic air passage, with internal thread and PAW flange for warm water central heating PN 10, 120 C, suited for horizontal and vertical installation. Can also be used as non-return valve. To be screwed directly to the pump. Opening pressure 200 mm wc. Nominal diameter PAW flange Internal thread Length (without nut) DN 20 (¾") 1" ¾" 45mm DN 25 (1") 1" 1" 45 mm DN 25 (1") 1" 1" 57 mm Prices excl. VAT 01/2017 Printed in Germany PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu

179 Illustration Item no. / piece Check valve SBE-AG Check valve, can be opened, with external thread and PAW flange for warm water central heating PN 10, 120 C, suited for horizontal and vertical installation. Can also be used as non-return valve. To be screwed directly to the pump. Opening pressure 200 mm wc. Nominal diameter PAW flange External thread Length (without nut) DN 25 (1") 1" 1" 57 mm Check valve with automatic air passage SBE-AG Check valve, can be opened, with automatic air passage, with external thread and PAW flange for warm water central heating PN 10, 120 C, suited for horizontal and vertical installation. Can also be used as non-return valve. To be screwed directly to the pump. Opening pressure 200 mm wc. Nominal diameter External thread PAW flange Length (without nut) DN 25 (1") 1" 1" 57mm Elbow check valve - with check valve, can be opened manually, automatic air passage - with connection for automatic air vent (½" sleeve) opening pressure 200 mm wc Nominal diameter PAW flange Internal thread Length (without nut) DN 25 (1") 1" ½" 50mm Check valve SBS Check valve, can be opened, with external thread and PAW flange for warm water central heating PN 10, 120 C. Very short height. Suited for horizontal and vertical installation. Opening pressure 200 mm wc. Nominal diameter PAW flange External thread Length (without nut) DN 25 (1") 1" 1" 30 mm Check valve with automatic air passage SBS Check valve, can be opened, with automatic air passage, with external thread and PAW flange for warm water central heating PN 10, 120 C. Very short height. Suited for horizontal and vertical installation. Opening pressure 200 mm wc. Nominal diameter PAW flange External thread Length (without nut) DN 25 (1") 1" 1" 30 mm Non-return valve ES The PAW non return valve is directly inserted into the thread connection of the circulation pump. Nominal diameter PAW flange Ø H (without nut) DN 20 (¾") ½" 20 mm 2 mm DN 20 (¾") ¾" 20 mm 2 mm DN 25 (1") 1" 25 mm 2 mm DN 32 (1¼") 1¼" 32 mm 2 mm Non-return valve with automatic air passage ES The PAW non return valve is directly inserted into the thread connection of the circulation pump. Nominal diameter PAW flange Ø H (without nut) DN 25 (1") 1" 25 mm 2 mm DN 32 (1¼") 1¼" 32 mm 2 mm Heating fittings Prices excl. VAT 01/2017 Printed in Germany PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu 179

180 Illustration Item no. / piece Sleeve check valve MR Nominal diameter Internal thread Internal thread Length DN 15 (½") ½" ½" 48 mm DN 20 (¾") ¾" ¾" 52 mm DN 25 (1") 1" 1" 59mm DN 32 (1¼") 1¼" 1¼" 67 mm DN 40 (1½") 1½" 1½" 71 mm DN 50 (2") 2" 2" 79 mm Sleeve check valve MA -Type 2 Flow in the direction of the internal thread Nominal diameter Internal thread External thread Length DN 15 (½") ½" ½" 53 mm DN 20 (¾") ¾" ¾" 59mm DN 25 (1") 1" 1" 67 mm DN 32 (1¼") 1¼" 1¼" 74 mm Sleeve check valve MA - Type 1 Flow in the direction of the external thread Nominal diameter Internal thread External thread Length DN 15 (½") ½" ½" 53 mm DN 20 (¾") ¾" ¾" 58mm DN 25 (1") 1" 1" 64 mm Solar check valve RSS with brass valve plate, all installation positions possible, opening pressure 200 mm wc, internal thread ¾", length = 50 mm 1211: can be opened, up to 150 C 12111: without possibility of manual opening, up to 220 C Nominal diameter Internal thread (G) Length DN 20 (¾") ¾" 50 mm DN 20 (¾") ¾" 50 mm Heating fittings 180 Prices excl. VAT 01/2017 Printed in Germany PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu

181 Safety sets and heating equipment Illustration Item no. / piece Boiler safety group KSG DN 25 up to 50 kw Boiler safety group KSG DN 25 up to 100 kw Boiler safety group KSG DN 25 up to 100 kw Boiler safety group KSG DN 25 up to 200 kw Boiler safety group KSG DN 32 up to 300 kw completely mounted, consisting of: 1 wall bracket 1 heating manometer d = 63 mm, 0-4 bars with automatic isolation 1 pressure relief valve 3 bars, firmly sealed 1 automatic air vent 3/8", with automatic isolation, 1 EPS insulation 5201: pressure relief valve ½", brass bracket, 1" internal thread 5202: pressure relief valve ¾", steel bracket, 1" internal thread 52021: pressure relief valve ¾", brass bracket, 1" internal thread 5203: pressure relief valve 1", steel bracket, 1" internal thread 5204: pressure relief valve 1¼", steel bracket, 1¼" internal thread Tank connection coupling, ¾" GAG/heating up to 50 kw completely mounted, consisting of: 1 wall bracket ¾" female thread 1 heating manometer d = 63 mm, 0-4 bars with automatic isolation 1 pressure relief valve ½", 3 bars, 1 automatic air vent 3/8" with automatic isolation 1 tank connector ¾", 2 screws and wall plugs Safety group SID DN 25 up to 50 kw for straight piping - with pressure relief valve ½", opening pressure 3 bars - with pressure gauge 0-4 bars, with shut-off valve Safety group DN 25 up to 50 kw for the installation on a modular distribution manifold DN 25, with a connection of ¾" int. thread (sealed with plug) for the installation of the connection set for the expansion tank (item no. 7507), pressure relief valve ½" x ¾", 3 bars, up to 50 kw, pressure gauge 0-4 bars Safety group DN 32 up to 100 kw for the installation on a modular distribution manifold DN 32, with a connection of 1" int. thread (sealed with plug) for the installation of the connection set for the expansion tank (item no. 7508), pressure relief valve ¾" x 1", 3 bars, up to 100 kw, pressure gauge 0-4 bars Pressure relief valve ½" x ¾", 3 bars, up to 50 kw Pressure relief valve ¾" x 1", 3 bars, up to 100 kw Pressure relief valve with pressure gauge up to 50 kw Pressure relief valve for closed heating systems Opening pressure: 3 bars Flush and drain set DN Flush and drain set DN Flush and drain set DN x counter-t-pieces with fill and drain valve, each equipped with an extension piece, permits to flush and drain individual HeatBloCs. Heating fittings Prices excl. VAT 01/2017 Printed in Germany PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu 181

182 Illustration Item no. / piece Counter cross DN Connection top: 1" external thread, self-sealing with o-ring and counter nut Connection bottom: 1" internal thread Connections side: ¾" internal thread Connection front: 3/8" internal thread Counter elbow ¾" external thread, self-sealing with o-ring and counter nut ½" external thread, self-sealing with o-ring and counter nut Dial thermometer d = 50 mm with red scale Dial thermometer d = 50 mm with blue scale Measuring range C, immersion shaft 25 mm, with self-sealing immersion sleeve, d = 50 mm Pressure gauge 3/8" Pressure gauge with automatic isolation Measuring range: 0-4 bars Diameter: d = 63 mm Shut-off valve: ½" x 3/8" Automatic air vent 3/8" external thread Automatic air vent ½" external thread self-sealing, with automatic isolation Microbubble resorber ¾'' Microbubble resorber 1'' Microbubble resorber 1¼'' Microbubble resorber 1½'' with automatic air vent completely made of brass, stainless steel grid and drain connection ½'' for sludge removal, for the use in heating systems, connections = internal thread, max. speed through the microbubble resorber 1.2 m/s 52373: L = 78 mm, up to 22.7 l/min or 1.36 m³/h 52374: L = 110 mm; up to 35.3 l/min or 2.12 m³/h 52375: L = 124 mm; up to 57.8 l/min or 3.47 m³/h 52376: L = 124 mm; up to 90.5 l/min or 5.43 m³/h Tank connection coupling ¾", plastic, max. operating temperature 100 C Tank connection coupling ¾", brass, max. operating temperature 130 C Tank connection coupling ¾" with automatic shut-off valve for expansion tank, allows the expansion tank to be easily dismounted and separated from the heating installation during servicing or replacement, max. pressure 10 bars Heating fittings Tank connection coupling with cap valve ¾" Tank connection coupling with cap valve 1" allows the expansion tank to be easily dismounted and separated from the heating installation during servicing or replacement, max. operating temperature 120 C, max. pressure 6 bars Connection set for diaphragm expansion tank for assembly to the safety group DN 25 with self-sealing double nipple ¾" and mounting equipment, tank connector ¾", armoured hose with bend ¾" x 700 mm, maximum tank diameter = 440 mm 182 Prices excl. VAT 01/2017 Printed in Germany PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu

183 Illustration Item no. / piece Connection set for diaphragm expansion tank for assembly to the safety group DN 32 with self-sealing double nipple 1", cap valve 1", armoured hose with bend 1" x 700 mm. Fill and drain valve ½" solid design, with hose connector and cap, completely made of brass, self-sealing counter nut ½" Conversion kit for thermal control valve from flow on the left to flow on the right 34044R - Conversion kit for thermal control valve from flow on the right to flow on the left 34044L - to change the flow line of the K33MAX Conversion kit for K33MAX with thermal control valve for flow on the right Conversion kit for K33MAX with thermal control valve for flow on the left to convert a K33 HeatBloC to a K33MAX with thermal control valve with 45 C cartridge, adjustable from C Conversion kit from K33/34 to K32 for PAW mixing valve DN 20/DN Before: K33- and K34 mixing valve (with bypass on the back), DN 20/DN 25 After: K32 - DN 25/DN 20, flow right + flow left Conversion kit from K33/34 to K33 flow right, bypass on the front, for PAW mixing valve DN 25 from flow on the left to flow on the right Before: K33 mixing valve (with bypass on the front), DN 25, flow left After: K33 - DN 25 (with bypass on the front), flow right Conversion kit from K33/34 to K33 flow left, bypass on the front, for PAW mixing valve DN 25 from flow on the right to flow on the left Before: K34 mixing valve (with bypass on the front), DN 25 K33 mixing valve (with bypass on the front), DN 25, flow right After: K33 - DN 25 (with bypass on the front), flow left Conversion kit from K33 to K34, bypass on the front, for PAW mixing valve DN Before: K33 mixing valve (with bypass on the front), DN 25 After: K34 - DN 25 (with bypass on the front), flow right + flow left Heating fittings Prices excl. VAT 01/2017 Printed in Germany PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu 183

184 Stainless-steel corrugated hose The elastic pipe for a flexible connection. Material corrugated hose: (DIN 17440) Material fittings and union nuts: brass Minimum length 5 m per roll L = Length of the stainless-steel corrugated hose Technical data stainless-steel corrugated hoses Nominal diameter Inside diameter Outside diameter Wall width Nominal pressure Burst pressure Operating temperature Bending radius (min) DN 15 (½") 16 mm 22 mm 0.25 mm 12 bars 120 bars -30up to +180 C 45 mm DN 20 (¾") 20 mm 26.8 mm 0.25 mm 10 bars 80 bars -30up to +180 C 60 mm DN 25 (1") 25 mm 32.3 mm 0.30 mm 8 bars 70 bars -30up to +180 C 75 mm DN 32 (1¼") 32 mm 41.5 mm 0.30 mm 6 bars 65 bars -30up to +180 C 100 mm Stainless-steel corrugated hose Item no. / piece Material Minimum length 5 m per roll more than 50 m per roll on request When ordering by metre, please indicate:... rolls with... metres per roll Length DN 15 (½") 6 m DN 15 (½") by the metre in rolls DN 20 (¾") 6 m DN 20 (¾") by the metre in rolls DN 25 (1") 6 m DN 25 (1") by the metre in rolls DN 32 (1¼") 6 m DN 32 (1¼") by the metre in rolls Heating fittings Connection internal thread for stainless-steel corrugated hose Scope of delivery: 1 stainless-steel holding ring, 1 screw-in fitting, 1 union nut, 1 gasket DN 15 (½") ½" internal thread DN 20 (¾") ¾" internal thread DN 25 (1") 1" internal thread DN 32 (1¼") 1 ¼" internal thread Connection external thread for stainless-steel corrugated hose Scope of delivery: 1 stainless-steel holding ring, 1 screw-in fitting, 1 union nut, 1 gasket DN 15 (½") ½" external thread DN 20 (¾") ¾" external thread DN 25 (1") 1" external thread DN 32 (1¼") 1 ¼" external thread Prices excl. VAT 01/2017 Printed in Germany PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu

185 Flexan Flexan is a fitting system for flexible connections, it permits to quickly compensate length differences and offsets, for example for the assembly or exchange of radiators. Stretchable by 75 %. Not suitable for dynamic load! In compliance with the Italian norms - UNI-CIG 7129/72 - UNI-CIG 8041/85 - UNI-CIG 8042/85 Technical DATA FLEXAN Materials Flexan Stainless steel Nut Brass, nickel-plated Technical data Operating temperature -30 up to +180 C Nominal pressure 16 bars Burst pressure > 60 bars Flexan mm, with 1 gasket Item no. / piece Nominal diameter Connection 1 Connection 2 Length DN 10 (3/8") 3/8'' ext. thread 3/8" nut mm DN 15 (½") ½" ext. thread ½" nut mm DN 15 (½'')-20 (¾'') ½" ext. thread ¾" nut mm DN 20 (¾") ¾" ext. thread ¾" nut mm DN 25 (1") 1" ext. thread 1" nut mm DN 32 (1¼") 1¼" ext. thread 1 ¼" nut mm Flexan mm, with 1 gasket Item no. / piece Nominal diameter Connection 1 Connection 2 Length DN 10 (3/8") 3/8'' ext. thread 3/8" nut mm DN 15 (½") ½" ext. thread ½" nut mm DN 15 (½'')-20 (¾'') ½" ext. thread ¾" nut mm DN 20 (¾") ¾" ext. thread ¾" nut mm DN 25 (1") 1" ext. thread 1" nut mm DN 32 (1¼") 1¼" ext. thread 1 ¼" nut mm Flexan mm, with 1 gasket Item no. / piece Nominal diameter Connection 1 Connection 2 Length DN 15 (½") ½" ext. thread ½" nut mm DN 15 (½'')-20 (¾'') ½" ext. thread ¾" nut mm DN 20 (¾") ¾" ext. thread ¾" nut mm DN 25 (1") 1" ext. thread 1" nut mm DN 32 (1¼") 1¼" ext. thread 1 ¼" nut mm Flexan mm, with 1 gasket Item no. / piece Nominal diameter Connection 1 Connection 2 Length DN 15 (½") ½" ext. thread ½" nut mm Flexan mm, with 1 gasket Item no. / piece Nominal diameter Connection 1 Connection 2 Length DN 15 (½") ½" ext. thread ½" nut mm Heating fittings Prices excl. VAT 01/2017 Printed in Germany PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu 185

186 Subject index Item Page A Accessories domestic hot water technology Accessories modular distribution manifolds 53, 95, 129, 151, 155 Accessories modular heating circuits 56-58, , , 151, 155, Accessories solar stations , Accessory kit for actuator 173 Accessory kit for storage tank installation 257 Actuators 172 Adapter piece to extend the mixing valve shaft 173 Adapter set for mixing valve shaft 173 Air heater connection set 169 Airstop (microbubble resorber) 182 App App MCom 23 App Service 36 Automatic air vent 182 Automatic vent valve 182 Automatic, dynamic balancing of the distribution manifold B Balancing of the distribution manifold Ball valves Boiler charging set, MC series DN DN Boiler charging set, standard series DN DN DN Boiler hose 185 Boiler safety groups 181 Boiler temperature maintenance 48, 86, 122, Bypass 44, 46, 48, 66, 67, 78, 80, 82, 86, 108, 109, 120, 122, 158 Bypass set 169 C Cascade FriwaMaxi FriwaMega FriwaMidi SolexMega (domestic hot water system) SolexMega (heating system) Charging set for wood-fired boiler, MC series DN DN Charging set for wood-fired boiler, standard series DN DN DN Check valves Check valves, for solar applications 180, 256, 266 Circulation set for FriwaMaxi/Mega-Kaskade 197, 199, 200 for FriwaMega 199, 200 for FriwaMidi/Maxi 195, 197, 200 for FriwaMidi/Maxi/Mega-Kaskade 195, 197, 199, 200 for tank heat transfer module Maxi 209 for tank heat transfer module Midi 207 Connection coupling for expansion tank 181 Connection set for expansion tank 181, 182, 256 Connection set for MCom controller 64, 65, 66, 67, 68, 106, 107, 108, 109, 140, 141, 142, 143 Contact thermostat 47, 58, 83, 100, 121, 134 Control valve Controlled circuits with constant value, MC series DN DN Controlled circuits with constant value, standard series DN DN Controller FC3.8 for DHW modules Friwa 191 Controller MCom for HeatBloCs MC series 64-69, , Controller SC3.6 for solar stations SolarBloC 241 Controller SC5.14 for solar transfer stations Solex 215 Conversion kit for conversion into low-loss header 55, 58, 97, 100, 131, 133, 151, 155 Conversion kits for mixing valves 183 Corrugated hoses Counter cross, self-sealing 182 Counter elbow, self-sealing 182 Coupling pieces 57, 98, 133 Cutting-ring compression fittings 56, 99, 161, 163, 257, 266 D DHW module Friwa FriwaMaxi/cascade FriwaMega/cascade FriwaMidi/cascade FriwaMini Dial thermometers 170, 182, 254, 264 Discharge tundish for DHW storage tank 200 Distribution manifolds DN DN DN DN DN Domestic hot water station , Double nipple 257 Drain set 56, 99, 132, 181, 256, 257, 266 E Extension for ball valve spindle 176 Extension for mixing valve shaft 173 Extension module for distribution manifold 53, 95, 129 Extension pipe set for 3 HeatBloCs K35 85 Extension set MCom 90-91, F Fill and drain valve 183 Fine filter for solar fluid 256 Fitting for assembly 58, 98, 132 Fitting for heat flowmeter 58, 98, 132 Flanges 151, 155 Flexan (flexible corrugated hose connection) 185 Floor bracket for modular distribution manifold DN 40, DN , 155 Flow set 168, 170 Flush and fill units 56, 99, 132, 181, 256, 257, 266 Four-way mixing valve DN DN G Gaskets 57, 161, 163, 177 H Hand filling and injection pump 256, 257, 266 Hand refractometer 267 HeatBloCs DN DN /2017 Printed in Germany PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu

187 Subject index DN DN DN HeatBloCs MC DN DN DN DN Heating circuits MC series DN DN DN DN Heating circuits standard series DN DN DN DN DN Heating equipment Heating pressure gauge 182 Heating pressure relief valves 181 Heating pumps, overview Heating separation systems Hose connector 257, 266 Hydraulic balancing Hydraulic separator 54-55, 96-97, I Immersion sleeves 57, 99, 132, 256, 266 Injection pump 256, 257, 266 Insert fittings / Screw-in fittings 177 L Limit switch 173 Low-loss header DN DN DN M Maintenance unit for solar installations 256 MCom communication set 64, 65, 66, 67, 68, 69, 95, 106, 107, 108, 109, 110, 129, 140, 141, 142, 143 Maintenance unit for solar installations 256 Microbubble resorber 182 Mixing valve actuators and accessories Mixing valve with bypass 44, 46, 48, 66, 67, 78, 80, 82, 86, 108, 109, 120, 122, 158 Mixing valve, 3-temperature 68, Mixing valve, 3-way DN DN , DN , DN , 149 DN , 153 Mixing valve, 4-way DN DN Mixing valves for service water 200 DN DN DN DN DN Modular distribution system DN Modular heating circuits with bypass mixing valve, MC series DN DN Modular heating circuits with bypass mixing valve, standard series DN DN DN Modular heating circuits, MC series DN DN DN DN Modular heating circuits, standard series DN DN DN DN DN Mounting plate for modular heating circuits DN 20 41, 43, 45, 47, 53, 55, 56 DN 25 75, 77, 79, 83, 89, 95, 97, 98 DN , 119, 121, 125, 129, 131, 133 Multivalves 174 N Nipple, flat-sealing 257 Non-return valve for mixing valve return 56, 99, 100, 133 Non-return valves Non-return valves, for solar applications 180, 256, 266 O Overflow sets 56 P Paper gaskets (AFM34) 57, 161, 163, 177 Pipe set for cascade for cascade for FriwaMaxi 197, 201 for cascade for FriwaMega 199, 201 for cascade for FriwaMidi 195, 201 Piping group for hydraulic separator 55, 58, 97, 100, 131, 133 for one single HeatBloC K35 85 for two HeatBloCs K35 85 Pressure gauge 182, 267 Pressure relief valves 181 PSC 217, 245 Pump ball valves Pump fittings 177 Pump group direct (unmixed), MC series DN DN DN DN Pump group direct (unmixed), standard series DN DN DN DN DN Pump group with mixing valve, MC series DN DN DN DN Pump group with mixing valve, standard series DN DN DN /2017 Printed in Germany PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu 273

188 Subject index DN DN Pump sets Pump signal converter 217, 245 R Radiant floor heating circuits standard series DN DN , DN Radiant floor heating circuits MC series DN DN Radiant floor separation systems Reducing flanges 151, 155 Reducing pieces/fittings 98, 133 Refractometer 267 Replacement set for solar pumps 217, 245 Return distribution set 193, 195, 197, 199, 201, 207, 209, 224, 226 Return flow temperature maintenance 48, 86, 122 Return flow temperature maintenance with actuator Return flow temperature maintenance with thermal control valve Return set 168, 170 S Safety group for domestic hot water tank 200 Safety set 57, 100, 134, 181 Separation systems for heating installations Service water mixing valve 200 Service water tapping station , Shut-off valves 179 Siphon for domestic hot water tank 200 Socket check valves 180 Solar connection hose 257, 267 Solar hand filling pump 256, 257, 266 Solar pumps, overview 216, 244 Solar stations for 2 storage tanks / 2 collector fields type SolarBloC maxi Basic type SolarBloC maxi Premium type SolarBloC maxi return station type SolarBloC mega type SolarBloC midi 3-line station type SolarBloC midi Basic type SolarBloC midi Premium type SolarBloC midi return station with control , Solar transfer station type SolexMaxi HZ type SolexMaxi TW type SolexMega HZ type SolexMega TW type SolexMega-Kaskade HZ type SolexMega-Kaskade TW type SolexMidi HZ type SolexMidi TW type SolexMini HZ type SolexMini TW Spindle extension for ball valves 176 Stainless-steel corrugated hose Supplementary set for heat quantity measurement 250, 252 System separation T Tank connection coupling 181 Tank heat transfer module Maxi Tank heat transfer module Midi Temperature sensor Pt , 246, 248, 260, 262, 264 Thermal control 48-49, 86-87, Thermal mixing valve 44-45, 48-49, 78-81, 86-87, , Thermax Thermometer ball valves 175 Thermometer with immersion sleeve 170, 182, 254, 264 Thread connections 177 Thread connections for corrugated hose 184 Three-line stations Three-temperature mixing valve, DN 25 68, Three-way mixing valve DN DN , DN , DN , 149 DN , 153 Three-way zone valve (solar) DN , 220, 258 DN , 224, 267 DN Two-way zone valve (DHW) DN , 230 DN , 234, 236 Two-way zone valve (solar) DN , 220, 258 DN , 267 DN U Union nuts 57, 177 Unmixed (direct) heating circuits, MC series DN DN DN DN Unmixed (direct) heating circuits, standard series DN DN DN DN DN V Vent valve 182 W Wall bracket for HeatBloC DN for HeatBloC DN 25 - DN 32 99, 133 for modular distribution manifold DN for modular distribution manifold DN 25 - DN 32 99, 133 Wall bracket set 56, 99, 133 Withdrawal valve 195, 197, 19, 201, 207, /2017 Printed in Germany PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu

189 Item number index Item no. Page SOL , 254, 256, , , , 65, 66, 67, 68, 106, 107, 108, 109, 140, 141, 142, , 65, 66, 67, 67, 69, 95, 106, 107, 408, 409, 110, 129, 140, 141, 142, GU MGU MWG WG GU MGU MWG WG , , , , 55, 57, , 55, 57, , , , , , , 163, , , SOL 254, , SOL 254, , 97, 131, ISO , 45, 47, , , , 43, 45, 47, , 43, 45, 47, , 43, 45, 47, , 43, 45, 47, , 43, 45, 47, , 43, 45, 47, 53, 55, SET 41, 43, 45, 47, , 43, 45, 47, 53, , 43, 45, 47, 53, 55, , , 43, 45, 47, , 43, 45, 47, 53, KS1 55, , , 43, 47, 45, , 43, 45, 47, 56, GH GM WH WY GH GM WH WY GH GM WH WY GH GM WH WY GH GM M MGH MGM MWH MWY WH WY GH GM M MGH MGM MWH MWY WH WY GH GM WH WY GH GM WH WY GH GM WH WY , , L 81, R 81, , , , , , 77, 79, 73,89, , 77, 79, 83, 89, , 77, 79, 83, 89, , 77, 79, 83, 89, , 77, 79, 83, 89, SET 75, 77, 79, 81, 83, 89, , 77, 79, 83, 89, 95, , 77, 79, 83, 89, 95, 97, , 77, 79, 81, 83, 89, , , , KS1 97, , , 77, 79, 81, 83, 89, 99, , 75, 83, 89, 95, 97, 117, 119, 121, 125, 129, , , 77, 79, 73, 87, 89, 99, 117, 119, 121, 123, 125, , 77, 79, 81, 83, 89, 99, 117, 119, 121, 125, KS1 131, GH GL GM WH WY WY GH GL GM WH WY WY GH GL GM WH WY WY GH GL GM WH WY W GH GL GM M MGH MGL MGM MWH MWY MWY WH WY WY GH GL GM M MGH MGL MGM MWH MWY MWY WH WY WY GH GL GM WH WY WY GH GL GM M MGH MGL MGM MWH MWY MWY WH WY WY KS KS KS GH GL GM M MGH MGL MGM MWH MWY MWY WH WY WY , 125, /2017 Printed in Germany PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu 275

190 Item number index , 119, 121, 125, , 119, 121, 125, , 119, 121, 125, , 119, 121, 125, , 119, 121, 125, SET 117, 119, 121, 125, 129, , 119, 121, 125, 129, , 119, 121, 125, 129, 131, , 119, 121, 125, , , , 119, 121, 125, 132, GH GL GM WH WY WY GH GL GM WH WY WY GH GL GM WH WY WY GH GL GM M MGH MGL MGM MWH MWY MWY WH WY WY GH GL GM M MGH MGL MGM MWH MWY MWY WH WY WY GH GL GM M MGH MGL MGM MWH MWY MWY WH WY WY GH GL GL WH WY WY WY M MGH MGL MGL MWH MWY MWY MWY , , , , , 79, 83, 89, , , 121, 125, GU WG GU WG MGU MWG MGU MWG MGU MWG MGU MWG GU WG GU WG MGU MWG MGU MWG MGU MWG GH MGH GH MGH GH GL WS WY M MGH MGL MWS MWY , , 134, , , 43, 45, 47, 56, , 43, 45, 47, 56, 257, , 43, 45, 47, 56, 257, , 43, 45, 47, 56, 257, , 77, 79, 81, 83, 89, 99, , 77, 79, 81, 83, 89, 99, , 77, 79, 81, 83, 89, 99, , 220, , 220, , , 222, , , 234, , , , 99, 132, 256, , 57, 97, 99, 131, 132, 256, , 99, , 99, 132, 256, , 99, 132, GH GP GP WH WY GH GP GP WP WY GH WS , 197, GH7 199, GH10 199, GH10 195, 197, 199, 200, GH12 197, 199, GH7 195, 197, 199, 200, 207, , 197, 199, 201, 207, , 201, , 201, , 197, 199, 201, , 201, , , , , , 83, 89, 100, 119, 121, 125, 134, , 134, 151, 155, , 47, 58, , 47, 58, , , 134, , 134, , , , , , , GP GP WH WY GP GP WH WY GP GP WH WY GP GP WH WY GP GP WH WY GP GP WH WY GH GP GP WP WY GH GP GP WH WY , , , , /2017 Printed in Germany PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu

191 Item number index GH GM WH WY GH GM WH WY GH GM WH WY GH GM WH WY GH GL GM WH WY WY GM WY WY GL GL WH WY GL GL WH WY GH GM WH WY GH GM WH WY GH GM WH WY , 44, 46, 76, 78, 80, 82, 84, 118, 120, 149, 153 Q Q , 58, 83, 100, 121, 134 Q , 248, 260, 262, /2017 Printed in Germany PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu 277

192

193 Catalogue General information General Terms and Conditions, Manufacturer s warranty, Fax form 01/2017 Printed in Germany PAW GmbH & Co. KG D Hameln Germany Phone: Fax: info@paw.eu 279

Catalogue Smart system technology for modern heating, solar thermal systems & domestic hot water technology.

Catalogue Smart system technology for modern heating, solar thermal systems & domestic hot water technology. Heating technology Domestic hot water Solar thermal systems Flat stations Catalogue 01 2019 Smart system technology for modern heating, solar thermal systems & domestic hot water technology Valid for the

More information

K35 HeatBloC with 3-temperature mixing valve

K35 HeatBloC with 3-temperature mixing valve PAW GmbH & Co. KG Böcklerstr. 11, D-31789 Hameln, Germany Phone: +49-5151-9856-0, Fax: +49-5151-9856-98 E-mail: info@paw.eu, Web: www.paw.eu Installation and Operation Instructions K35 HeatBloC with 3-temperature

More information

Installation and Operation Instructions K38 HeatBloC - DN 32

Installation and Operation Instructions K38 HeatBloC - DN 32 PAW GmbH & Co. KG Böcklerstr. 11, D-31789 Hameln, Germany Phone: +49-5151-9856-0, Fax: +49-5151-9856-98 E-mail: info@paw.eu, Web: www.paw.eu Installation and Operation Instructions K38 HeatBloC - DN 32

More information

Installation and Operation Instructions HeatBloC K31 - DN 25

Installation and Operation Instructions HeatBloC K31 - DN 25 PAW GmbH & Co. KG Böcklerstr. 11, D-31789 Hameln Phone: +49-5151-9856-0, Fax: +49-5151-9856-98 E-mail: info@paw.eu, Web: www.paw.eu Installation and Operation Instructions HeatBloC K31 - DN 25 2015/03

More information

Product range Solex Technical data and dimensioning. 5 Years

Product range Solex Technical data and dimensioning. 5 Years Qualität made in Germany Product range Solex Technical data and dimensioning Quality made in Germany 5 Years Handwerkergarantie m anufacturer s warranty Product range Solex Dimensioning High-Flow system

More information

Installation and Operation Instructions K31 HeatBloC - DN 50

Installation and Operation Instructions K31 HeatBloC - DN 50 PAW GmbH & Co. KG Böcklerstr. 11, 31789 Hameln, Germany Phone: +49-5151-9856-0, Fax: +49-5151-9856-98 Email: info@paw.eu, Web: www.paw.eu Installation and Operation Instructions K31 HeatBloC - DN 50 2013/05

More information

Catalogue Solar stations DN 20. Solar thermal solutions. Valid for the UK

Catalogue Solar stations DN 20. Solar thermal solutions. Valid for the UK Catalogue 01 2016 Solar stations DN 20 Solar thermal solutions Valid for the UK Overview product range SolarBloC Solar stations Performance data SolarBloC midi Premium SolarBloC maxi Premium SolarBloC

More information

Pump Stations for Heating Circuits

Pump Stations for Heating Circuits Pump Stations for Heating Circuits circulation pumps pump stations manifolds Regulus spol. s r.o., Czech Republic Do Koutů 897/, Praha Tel.: + 7 9, Fax: + 7 97 E-mail: sales@regulus.eu Web: www.regulus.eu

More information

Installation and Commissioning Instructions High Temperature Zone Module F31-1" (DN 25)

Installation and Commissioning Instructions High Temperature Zone Module F31-1 (DN 25) PAW GmbH & Co. KG Böcklerstr. 11, D-31789 Hameln, Germany Tel.: +49-5151-9856-0, Fax: +49-5151-9856-98 Email: info@paw.eu, Web: www.paw.eu Installation and Commissioning Instructions High Temperature Zone

More information

PRODUCTS FOR HEATING AND TAP WATER SYSTEMS. Product Catalogue

PRODUCTS FOR HEATING AND TAP WATER SYSTEMS. Product Catalogue PRODUCTS FOR HEATING AND TAP WATER SYSTEMS Product Catalogue Table of Contents LK Armatur - A One-Stop Supplier...5 LK 811 ThermoMat - Simple and precise... 8 Loading Units... 9 LK 810 ThermoMat 2.0 G

More information

HERZ PUMPFIX HERZ PUMPFIX. Datasheet 1 45XX XX, Issue Table of contents. Page 1. General information about HERZ PUMPFIX pump groups...

HERZ PUMPFIX HERZ PUMPFIX. Datasheet 1 45XX XX, Issue Table of contents. Page 1. General information about HERZ PUMPFIX pump groups... Datasheet 1 45XX XX, Issue 0216 Table of contents General information about pump groups...2 Direct (1 4510 XX)...4 DN 20 DN 25 DN 32 Mix (1 4511 XX)...6 DN 20 DN 25 DN 32 Mix with bypass (1 4511 XX)...10

More information

FCU Floor Control Unit

FCU Floor Control Unit Fully assembled with integrated M3V Control Group including mixing valve and circulating pump and in-line high and low temperature Topway T2 FM manifold options with high and low temperature manifold options

More information

Dynacon. Floor Heating Manifolds Floor heating manifold with automatic flow control

Dynacon. Floor Heating Manifolds Floor heating manifold with automatic flow control Dynacon Automatic Flow Control Floor Heating Manifolds Floor heating manifold with automatic flow control IMI HEIMEIER / Floor Heating Control / Dynacon Dynacon Dynacon adjusts the flow rate in the individual

More information

Application technology, 5th edition. Volume III: Fonterra radiant heating and cooling

Application technology, 5th edition. Volume III: Fonterra radiant heating and cooling Application technology, 5th edition Volume III: Fonterra radiant heating and cooling Regulation components, manifolds and manifold cabinets Regulation components, manifolds and manifold cabinets System

More information

Lowara Ecocirc Vario (EV)

Lowara Ecocirc Vario (EV) Lowara Ecocirc Vario (EV) The speed of the pump can be manually regulated to meet the requirement of the system. The software enables a choice from infinite number of performance curves. Spherical Rotor/Stator

More information

DISTRIBUTION GROUP WITH THERMOSTATIC REGULATION. Upper connections G1 F Without fittings Fittings with running connection* Without pump

DISTRIBUTION GROUP WITH THERMOSTATIC REGULATION. Upper connections G1 F Without fittings Fittings with running connection* Without pump Description This preassembled pump group is part of the arberi trolli HEATING line. This distribution group allows the circulation of the thermal fluid, coming from the primary circuit and it maintains

More information

Floor heating manifold with automatic flow control

Floor heating manifold with automatic flow control dynacon Floor heating manifold with automatic flow control Pressurisation & Water Quality Balancing & Control Thermostatic Control EnGInEERInG advantage dynacon adjusts the flow rate in the individual

More information

One-Stop Service: Monitoring and Managing.

One-Stop Service: Monitoring and Managing. One-Stop Service: Monitoring and Managing. The highest quality from the market leader Solar-Log devices are the most accurate and reliable data loggers on the market. Offer your customers high-quality

More information

Flow-compensated temperature controller AVTQ DN 15

Flow-compensated temperature controller AVTQ DN 15 Data sheet Flow-compensated temperature controller AVTQ DN 15 Description AVTQ is a self-acting flow-compensated temperature controller primarily for use in district heating systems with plate heat exchangers

More information

Primary switch mode power supplies CP range

Primary switch mode power supplies CP range Primary switch mode power supplies CP range ABB power supply units: CP range Modern power supply units are a vital component in most areas of energy management and automation technology. ABB as your global

More information

SMA Utility Power System

SMA Utility Power System EN SMA Utility Power System Integrated. Reliable. Profitable. Worldwide. Profitability is key Facilitate your PV power plant business with SMA You want to realize PV projects with maximum profits and minimized

More information

Schüco Premium Collectors Outstanding quality, performance and design

Schüco Premium Collectors Outstanding quality, performance and design Schüco Premium Collectors Outstanding quality, performance and design 2 Schüco Premium collectors Schüco Premium line collectors - The next generation Since its entry into the solar thermal sector, Schüco

More information

MANIFOLDS & WATER TEMPERATURE CONTROL

MANIFOLDS & WATER TEMPERATURE CONTROL MANIFOLDS & WATER TEMPERATURE CONTROL Overview Water based underfloor heating (UFH) systems work by turning the entire floor into one large low temperature radiator which is heated via a network of pipes

More information

COMPONENTS FOR SOLAR THERMAL SYSTEMS

COMPONENTS FOR SOLAR THERMAL SYSTEMS COMPONENTS FOR SOLAR THERMAL SYSTEMS The Caleffi Solar product range has been specially developed for use in solar thermal systems, where high temperatures can normally be reached and where, depending

More information

Success made in Germany

Success made in Germany RESOL Your partner for solar thermal and control technology since 1977 RESOL has more than 100 employees RESOL products control over 3 million systems in more than 60 countries Success made in Germany

More information

SOLAR THERMAL EQUIPMENT

SOLAR THERMAL EQUIPMENT SOLAR THERMAL EQUIPMENT 6 DIRECT FLOW CPC COLLECTOR Rhico direct flow CPC collectors are acknowledged as the market s premium product. With an extremely low heat loss and optically efficient cylindrical

More information

COMPONENTS FOR SOLAR THERMAL SYSTEMS

COMPONENTS FOR SOLAR THERMAL SYSTEMS COMPONENTS FOR SOLAR THERMAL SYSTEMS 2012 2 The CALEFFI SOLAR product range has been specially developed for use in solar thermal systems, where high temperatures can normally be reached and where, depending

More information

LK Manifold Shunt VS2

LK Manifold Shunt VS2 LK Manifold Shunt VS2 Design LK Manifold Shunt VS2 is a shunt unit with a two way control valve used in systems with a primary pump. The shunt unit is mountable from both the left and right of LK Manifolds.

More information

2/2-way Angle-Seat Valve for medium up to +180 C, threaded port connection, DN 15-65

2/2-way Angle-Seat Valve for medium up to +180 C, threaded port connection, DN 15-65 2/2-way Angle-Seat Valve for medium up to +180 C, threaded port connection, DN 15-65 Type 2000 can be combined with High flow rate Long life cycle NC and NO universal s with modular universal accessory

More information

Valves, controls + systems Stations for the connection heat generator/heating circuit

Valves, controls + systems Stations for the connection heat generator/heating circuit Innovation + Quality Valves, controls + systems Stations for the connection heat generator/heating circuit Product range 1 bar 0 4 OV Boiler valves With the boiler connection system, Oventrop offers all

More information

CBU144. Compact Booster Unit - single pump To ensure the quality of potable water according to EN1717. Product specification sheet

CBU144. Compact Booster Unit - single pump To ensure the quality of potable water according to EN1717. Product specification sheet CBU144 Compact Booster Unit - single pump To ensure the quality of potable water according to EN1717 Product specification sheet Version The Compact Booster Unit consists of the following modules, that

More information

Motors- Basic principles. Expertise, performance, innovation

Motors- Basic principles. Expertise, performance, innovation Motors- Basic principles Expertise, performance, innovation As a leading supplier of ventilation and drive engineering technology, ebm-papst is a highly respected engineering partner in many industries.

More information

Valves, controls + systems Valves and controls for solar installations Regusol-180

Valves, controls + systems Valves and controls for solar installations Regusol-180 The Oventrop Quality Management System is certified to DIN-EN-ISO 9001 Application: The Oventrop programme for solar installations allows the connection of the collector to the storage cylinder within

More information

HERZ-Connect 4 / Compact Connect 4 & Commissioning Centres

HERZ-Connect 4 / Compact Connect 4 & Commissioning Centres www.herz.eu HERZ-Connect 4 / Compact Connect 4 & Commissioning Centres Simple and cost efficient methodes of thermal units control 1 Connect 4.indd 1 17.11.2015 10:31:20 HERZ- Connect 4 HERZ Connect-4

More information

Webasto Service 360. The best approach to an optimal solution is all-round.

Webasto Service 360. The best approach to an optimal solution is all-round. Webasto Service 360 The best approach to an optimal solution is all-round. A new approach to Service. Webasto is present with over 50 locations around the world. Our roof and convertible roof as well as

More information

7 Services Control and monitoring

7 Services Control and monitoring Control and monitoring 7 Services We are the only manufacturer of laboratory equipment who offers you fume cupboards and variable fume cupboard control all from one supplier. Benefit from our know-how

More information

Grundfos Home Booster

Grundfos Home Booster GRUNDFOS DATA BOOKLET Grundfos Home Booster UPA 15-9, UPA 15-12, UPA 15-16, UPA 12 5/6 Hz Grundfos Home Booster Table of contents 1. Product description 3 Applications..................................................................................

More information

savings flexibility recyclable LIGHTNESS FULL FLOW MECHANICAL STRENGTH IMPROVE CONTROL TECHNICAL BROCHURE aesthetic performance CHANGE

savings flexibility recyclable LIGHTNESS FULL FLOW MECHANICAL STRENGTH IMPROVE CONTROL TECHNICAL BROCHURE aesthetic performance CHANGE TECHNICAL BROCHURE aesthetic performance flexibility thermal comfort PREMIUM QUALITY MECHANICAL STRENGTH IMPROVE CHANGE LIGHTNESS savings high resistance to corrosion low and high temperature systems FULL

More information

Reliability is our profession

Reliability is our profession Reliability is our profession Drive components for wind turbines Siemens AG Am Industriepark 2 46562 Voerde Germany Phone +49 2871 92-4 Fax +49 2871 92-2487 E-Mail info@winergy-group.com www.winergy-group.com

More information

HOME & OUTDOOR POWER

HOME & OUTDOOR POWER HOME & OUTDOOR POWER www.cat.com/jointoday 0800 085 3370 INTRODUCING CAT HOME & OUTDOOR POWER Introducing the Cat RP Series of Portable Generators, a range of generators from 2.5-4.4kW, designed and engineered

More information

Ball Screws for Aerospace Applications. Built-to-print Built-to-spec Engineering services

Ball Screws for Aerospace Applications. Built-to-print Built-to-spec Engineering services Ball Screws for Aerospace Applications. Built-to-print Built-to-spec Engineering services Ball Screws for Aerospace Applications. Steinmeyer develops customized solutions for many applications in the aerospace

More information

VariFuel2/VariFuel2+ MOTORTECH Air/Gas Mixer. VariFuel2 MOTORTECH AIR/GAS MIXER

VariFuel2/VariFuel2+ MOTORTECH Air/Gas Mixer. VariFuel2 MOTORTECH AIR/GAS MIXER VariFuel2/VariFuel2+ MOTORTECH Air/Gas Mixer VariFuel2 MOTORTECH AIR/GAS MIXER General Information VariFuel2 MOTORTECH AIR/GAS MIXER MOTORTECH s VariFuel2 is a high-tech variable Venturi type air/gas mixer

More information

Combined automatic balancing valve AB-PM valve DN 10-32, PN 16

Combined automatic balancing valve AB-PM valve DN 10-32, PN 16 Data sheet Combined automatic balancing valve AB-PM valve DN 10-32, PN 16 Description AB-PM is a combined automatic balancing valve. It features three function in compact valve body: 1. Differential pressure

More information

underfloor heating PRODUCTS FOR UNDERFLOOR HEATING

underfloor heating PRODUCTS FOR UNDERFLOOR HEATING underfloor heating PRODUCTS FOR UNDERFLOOR HEATING Table of Contents LK 420 Minishunt... 3 LK 421 Manifold Shunt... 4 LK 422 Manifold Shunt... 5 Spare Parts and Accessories... 6 LK 430 Manifold... 7 LK

More information

dynacon floor heating manifold with automatic flow control

dynacon floor heating manifold with automatic flow control dynacon floor heating manifold with automatic flow control Pressurisation & Water Quality Balancing & Control Thermostatic Control EnGInEERInG advantage Dynacon Description HEIMEIER Dynacon floor heating

More information

GSR - your partner for valve technology. Welcome to the world of valve technology. Your GSR Team

GSR - your partner for valve technology. Welcome to the world of valve technology. Your GSR Team Welcome to the world of valve technology GSR - your partner for valve technology This is the world of solenoid valves, with and without explosion protection, of external medium-controlled valves and motorised

More information

SIHI multi Type MSC. Modular multistage pumps. Description. Construction. Applications. Optional special designs. Materials.

SIHI multi Type MSC. Modular multistage pumps. Description. Construction. Applications. Optional special designs. Materials. Modular multistage pumps SIHI multi Type MSC Description The SIHI multi MSC range of horizontal, ring-section multistage pumps have been designed for long-term reliability when pumping high pressure liquids.

More information

for massive duties. WAGNER PROTEC 2K Mixing and dosing system Robust and dependable. Easy to use. Rapid amortization.

for massive duties. WAGNER PROTEC 2K Mixing and dosing system Robust and dependable. Easy to use. Rapid amortization. for massive duties. WAGNER Mixing and dosing system www.wagner-group.com Robust and dependable. Easy to use. Rapid amortization. Those who mix this way have a clear advantage WAGNER the new mixing unit

More information

Combined automatic balancing valve AB-PM valve DN 15-25, PN 16

Combined automatic balancing valve AB-PM valve DN 15-25, PN 16 Data sheet Combined automatic balancing valve AB-PM valve DN 15-25, PN 16 Description AB-PM is a combined automatic balancing valve. It features three function in compact valve body: 1. Differential pressure

More information

Butterfly valves Leakage butterfly valves Ball valves

Butterfly valves Leakage butterfly valves Ball valves SO EVERYTHING KEEPS FLOWING Butterfly valves Leakage butterfly valves Ball valves Quality down to the smallest detail Butterfly valves and ball valves are the most used shutoff devices in process engineering.

More information

Circulation pumps. Wet rotor circulators and accessories. Heating Drinking water Solar Geothermy Condensate

Circulation pumps. Wet rotor circulators and accessories. Heating Drinking water Solar Geothermy Condensate Circulation pumps Wet rotor circulators and accessories eating Drinking water Solar Geothermy Condensate CATALOGUE alm produces highly-efficient heating circulation pumps alm has been successfully developing

More information

BUILDING AUTOMATION CONTROL TECHNOLOGY SENSOR TECHNOLOGY PRODUCT CATALOGUE Intelligent solutions for intelligent people.

BUILDING AUTOMATION CONTROL TECHNOLOGY SENSOR TECHNOLOGY PRODUCT CATALOGUE Intelligent solutions for intelligent people. BULDNG AUTOMATON CONTROL TECHNOLOGY SENSOR TECHNOLOGY PRODUCT CATALOGUE 2015 ntelligent solutions for intelligent people. ALRE-T Regeltechnik GmbH Your reliable partner. Soon, Alre T-Regeltechnik GmbH

More information

MENNEKES has the energy and the connections to create unique solutions for you worldwide.

MENNEKES has the energy and the connections to create unique solutions for you worldwide. MENNEKES MY POWER CONNECTION As a specialist for industrial plugs and sockets and a pioneer in electromobility, MENNEKES is shaping with you the market of the future. Driven by the courage to change and

More information

The next generation of controllers and valves

The next generation of controllers and valves The next generation of controllers and valves Vexve - The next generation of controllers and valves When you want to ensure the heating in your home is energy-efficient, it is crucial to find the right

More information

Costumer Service. Comprehensive technical support for NETZSCH customers

Costumer Service. Comprehensive technical support for NETZSCH customers Costumer Service Comprehensive technical support for NETZSCH customers NETZSCH Pumps & Systems Your partner for high quality products and first class service With NEMO progressing cavity pumps, TORNADO

More information

HERZ-Motorised flow controler

HERZ-Motorised flow controler HERZ-Motorised flow controler Control and regulating valve Data sheet 4006 SMART, Issue 0516 Dimensions in mm 4006 M 4006 R M R Order number DN G L L1 B B1 H without Actuator H with Actuator H1 1 4006

More information

Customised drive solutions

Customised drive solutions Customised drive solutions Electric motors & systems Drive components Services Introduction 03 Halm quality drive technology Over 50 years of experience in developing electric motors with asynchronous

More information

Pressure relief valve

Pressure relief valve Pressure relief valve Operating manual Series DHV 712 Version BA-2015.10.20 EN Print-No. 300 510 TR MA DE Rev001 ASV Stübbe GmbH & Co. KG Hollwieser Straße 5 32602 Vlotho Germany Phone: +49 (0) 5733-799-0

More information

New! NiroTherm. Premium solution for corrosive environments. exclusively from SANHA

New! NiroTherm. Premium solution for corrosive environments. exclusively from SANHA NiroTherm New! = Tool Compatibility + Push & Stay + Leak Path Feature exclusively from SANHA Premium solution for corrosive environments Optimal for heating, cooling and compressed air installations high

More information

BRILEX Venting Solutions

BRILEX Venting Solutions BRILEX Venting Solutions Professionally mitigate risks. Brilex Gesellschaft für Explosionsschutz mbh A Member of the HOERBIGER Group More than 20 years of experience! How long can you stay cool? BRILEX

More information

Hydraulics in HVAC Applications

Hydraulics in HVAC Applications www.herz.eu Hydraulics in HVAC Applications Preface Apart from the benefits of increased comfort and ease, the introduction of pumped warm water heating into buildings also produced problems in connection

More information

VALVE CONTROLLERS Controllers for Dust Extr 2010 / 2011 action Technology

VALVE CONTROLLERS Controllers for Dust Extr 2010 / 2011 action Technology VALVE CONTROLLERS Controllers for Dust Extraction 2010 Technology / 2011 Valve controllers for all cases HESCH has the skills and technology to tackle any control task for dedusting of filter and dust

More information

DC Cabling Ready for 1,500 V DC

DC Cabling Ready for 1,500 V DC DC Cabling Ready for 1,500 V DC Perfectly connected MADE IN GERMANY Reduce your LCOE with 1,500V DC architecture What causes PV costs? Since 2010 the PV market has changed a lot. PV module costs have been

More information

Perfect Liquid Handling PRECISE RESULTS WITH INNOVATIVE TECHNOLOGY

Perfect Liquid Handling PRECISE RESULTS WITH INNOVATIVE TECHNOLOGY Perfect Liquid Handling PRECISE RESULTS WITH INNOVATIVE TECHNOLOGY Reliability from development to service. Tradition Quality VITLAB can look back on a history of almost 100 years. VITRI GmbH & Co. KG

More information

CALEFFI. Motorised temperature regulating unit for heating and air conditioning systems WYP UPM series 01254/17 GB

CALEFFI. Motorised temperature regulating unit for heating and air conditioning systems WYP UPM series 01254/17 GB Motorised temperature regulating unit for heating and air conditioning systems 67...WYP - 67...UPM series CCREDITED ISO 9 FM 65 CLEFFI 5/7 G replaces dp 5/ G Function The motorised temperature regulating

More information

Press kit. 1. The company 02

Press kit. 1. The company 02 1 Press kit 1. The company 02 2. Press releases 2014 NEW: Type W Wizard now also available in atomic yellow and 8,0 x 18 03 AUTEC wheel configurator with TPMS information now 04 Concave and clear the new

More information

Charge up in Control MENNEKES Load Management. Intelligent charge and load management for operational safety and cost control

Charge up in Control MENNEKES Load Management. Intelligent charge and load management for operational safety and cost control Charge up in Control MENNEKES Load Management Intelligent charge and load management for operational safety and cost control Charging Safety - the Next Generation With the growth in Electric Vehicles on

More information

Options. 1 Test Station, Type ZT V/50Hz V/60Hz V/60Hz V/60Hz

Options. 1 Test Station, Type ZT V/50Hz V/60Hz V/60Hz V/60Hz Diesters ERWEKA ZT 120 Series Housing light grey (RAL 7035) 82-000-0423 Basket Cleaning and Media Preheat Station (ZT 121/123 only) 11-25x-x1xx USP compliant Quick-Clean Basket Rack Assembly instead standard

More information

General catalogue incl. replacement lists

General catalogue incl. replacement lists Circulation pumps effiziente Pumpentechnologie General catalogue 2009 incl. replacement lists Data might be subject to alteration, errors excepted! Content I. Product programme Product overview... 1 Type

More information

TRUCKTEC T R U C K T E C

TRUCKTEC T R U C K T E C T R U C K T E C H i s t o r y a n d P r o g r e s s TRUCKTEC a u t o m o t i v e H i s t o r y Our success proves we are doing it right. What started just yesterday is continuously evolving. We are developing

More information

LINEAR ACTUATORS. Type SL 95 / SL 80 / KL 95 up to 12,000 N with high protection class (IP)

LINEAR ACTUATORS. Type SL 95 / SL 80 / KL 95 up to 12,000 N with high protection class (IP) LINEAR ACTUATORS Type SL 95 / SL 80 / KL 95 up to 12,000 N with high protection class (IP) moving As one of the leading manufacturers of electrical and electronic drive components and systems we offer

More information

Japanese Technology since Ego Circulators. Databook

Japanese Technology since Ego Circulators. Databook Japanese Technology since 1912 Ego Circulators Databook Japanese Technology since 1912 www.ebaraeurope.com INDEX Ego Range GENERAL INTRODUCTION THREADED CIRCULATORS THREADED/FLANGED CIRCULATORS FLANGED

More information

Compact Heat Meters. Features. -A Pulsed output. -B M-Bus output. Accessories. UK Sales Tel: International Tel:

Compact Heat Meters. Features. -A Pulsed output. -B M-Bus output. Accessories. UK Sales Tel: International Tel: Compact Heat Meters Features Compact design Simple operation Pulsed output Measures heating or cooling Specification Product Codes Water Meter Temp. range 10 to 90 C Nominal pressure 16bar Installation

More information

Thermostatic radiator valves with presetting

Thermostatic radiator valves with presetting Thermostatic radiator valves TRV-2, TRV-2S Thermostatic radiator valves with presetting Pressurisation & Water Quality Balancing & Control Thermostatic Control ENGINEERING AVANTAGE Thermostatic radiator

More information

Superstatic 440. Static Heat Meter, Static Cooling Meter. Application

Superstatic 440. Static Heat Meter, Static Cooling Meter. Application Superstatic 440 Static Heat Meter, Static Cooling Meter Application Design The Superstatic 440 is a static heat or cooling meter according to standard EN1434 class 2 based on the fluid oscillation principle,

More information

KLINGER BALLOSTAR KHE 2-piece ball valves DN (1/2" 8")

KLINGER BALLOSTAR KHE 2-piece ball valves DN (1/2 8) KLINGER BALLOSTAR KHE 2-piece ball valves DN 15 0 (1/2" 8") www.klinger.kfc.at MF 01 KLINGER FLUID CONTROL Today for tomorrow As a subsidiary of the KLINGER Group, KLINGER Fluid Control has been developing,

More information

Components for central heating

Components for central heating 01 01 Components for central heating Booster units and spare parts 18 Hydraulic separator and spare parts 21 Dirt separators - Deaerators 23 By-Pass differential valve - Air separator units 32 Filling

More information

SINUS VERTEILER PRODUCT GUIDE

SINUS VERTEILER PRODUCT GUIDE SINUS VERTEILER PRODUCT GUIDE 2017/18 heating heating & cooling & cooling systems systems 1 CUSTOMER CARE EXPORTS The product configurator Stefan Engberding Head of Exports Phone: +49 (0) 2557 / 93 93-62

More information

VARTA Energy Storage Systems

VARTA Energy Storage Systems VARTA Energy Storage Systems 130 Years of Battery Expertise in Your Energy Storage System. The perfect combination of long-term experience and modern technology. www.varta-storage.com GOOD REASONS FOR

More information

Art.918C Pre-assembled manifold with flow meters, air

Art.918C Pre-assembled manifold with flow meters, air TECHNICAL CATALOGUE Art.98C Pre-assembled manifold with flow meters, air vent valves and drain cock TEC ITAP SpA, founded in Lumezzane (Brescia) in 97, is currently one of the leading production companies

More information

HS10S-FA. Water station. Product specification sheet

HS10S-FA. Water station. Product specification sheet HS10S-FA Water station Product specification sheet Range of Application Medium Drinking water Inlet pressure Max. 16 bar Outlet pressure 1.5-6.5 bar Installation position Horizontal with filter bowl downwards

More information

ROTEX variocistern Saving money on rainy days

ROTEX variocistern Saving money on rainy days ROTEX variocistern Saving money on rainy days Use rainwater efficiently and save costs. With the ROTEX variocistern rainwater storage tank. In our house the sun is always shining, even when it s raining.

More information

Butterfly valves Leakage butterfly valves Ball valves. Standard

Butterfly valves Leakage butterfly valves Ball valves. Standard Butterfly valves Leakage butterfly valves Ball valves Standard High standard with the option of security against leakage Quality down to the smallest detail Butterfly valves and ball valves are the most

More information

RVD120 RVD G2510. Installation. Place of installation. Electrical installation. Permissible cable lengths

RVD120 RVD G2510. Installation. Place of installation. Electrical installation. Permissible cable lengths en Installation Instructions District heating and d.h.w. controller 74 39 68 G25 RVD2 RVD4 Keep these instructions with the controller! Installation Place of installation In a dry room, e.g. the heat exchanger

More information

SolarMax 330TS-SV. The all-round solution for large-scale PV installations.

SolarMax 330TS-SV. The all-round solution for large-scale PV installations. SolarMax 0TS-SV The all-round solution for large-scale PV installations. Modular and flexible The best choice for PV installations is the SolarMax 0TS-SV, the inverter which is directly connected to medium

More information

Charge up at Work! Intelligent E-Mobility Solutions for Companies

Charge up at Work! Intelligent E-Mobility Solutions for Companies Charge up at Work! Intelligent E-Mobility Solutions for Companies Sustainable charging while you work E-Mobility and quality products for professional charging not only make your company fleet more economical,

More information

FILL UP WITH THE SUN AND TAKE OFF

FILL UP WITH THE SUN AND TAKE OFF E-Mobility 2018 E-CARPORT E-BIKEPORT FILL UP WITH THE SUN AND TAKE OFF Say yes to renewable energy. sonnenkraft.com MOVE FORWARD THE WAY TO THE FUTURE E-MOBILITY 2020 Politics and business show the way.

More information

KLINGER BALLOSTAR KHE

KLINGER BALLOSTAR KHE KLINGER KHE 2-piece ball valves DN 0 (1/2" 8") www.klinger.kfc.at MF 01 KLINGER FLUID CONTROL Today for tomorrow As a subsidiary of the KLINGER Group, KLINGER Fluid Control has been developing, manufacturing

More information

bott vario Professional vehicle equipment for your Mercedes-Benz Estate cars Vito Sprinter

bott vario Professional vehicle equipment for your Mercedes-Benz Estate cars Vito Sprinter bott vario Professional vehicle equipment for your Mercedes-Benz Estate cars Vito Sprinter bott vario Feel at home in your Mercedes-Benz 2 You ve decided to get a Mercedes-Benz. In taking this decision

More information

PLUG-AND-PLAY ENERGY STORAGE SOLUTION

PLUG-AND-PLAY ENERGY STORAGE SOLUTION PLUG-AND-PLAY ENERGY STORAGE SOLUTION BENEFITS AT A GLANCE PLUG-AND-PLAY. ALL IN ONE The Y.Cube is a ready-to-install storage system, with all components inside a single enclosure. This off-theshelf solution

More information

4 Specification Magneta Smedegaard twin pumps

4 Specification Magneta Smedegaard twin pumps 4 Specification Magneta Smedegaard twin pumps 4.1 Variable Speed Circulator Pumps Designation: Example Magneta Smedegaard 30-60D Key to the designation Main applications Heating, ventilation, air-conditioning,

More information

Datasheet PDCSY-MW-CHM. Technical Overview. Features. Product warranty and total quality commitment. General Information.

Datasheet PDCSY-MW-CHM. Technical Overview. Features. Product warranty and total quality commitment. General Information. Datasheet Compact Heat Meters Technical Overview Heat energy is calculated by using a matched pair of high accuracy sensors to measure the difference between the forward and flow temperatures. The amount

More information

TiBox HIGH-END ENERGY. The intelligent energy storage system utilising lithium-titanate

TiBox HIGH-END ENERGY. The intelligent energy storage system utilising lithium-titanate TiBox HIGH-END ENERGY The intelligent energy storage system utilising lithium-titanate Living with Leclanché free of energy concerns. Experience maximum and permanent security. Enjoy new independence with

More information

The World s Largest Injection Moulding Machine Manufacturer

The World s Largest Injection Moulding Machine Manufacturer The World s Largest Injection Moulding Machine Manufacturer Official Sales and Servicepartner of www.haitian.co.uk PRODUCTION AND GROWTH Established in 1966 and world leaders in injection moulding since

More information

Feed-in management with Solar-Log

Feed-in management with Solar-Log Feed-in management with Solar-Log 1 Publisher: Solare Datensysteme GmbH Fuhrmannstr. 9 72351 Geislingen-Binsdorf Germany International Support Tel.:+49 7428 9418-640 Fax:+49 7428 9418-280 E-mail: support@solar-log.com

More information

trak systemizer Turnkey charging & changing stations

trak systemizer Turnkey charging & changing stations www.hoppecke.com trak systemizer Turnkey charging & changing stations 1 HOPPECKE Batterien GmbH & Co. KG Bontkirchener Str. 1 D - 59929 Brilon Tel: +49 (0) 2963 61-0 Fax: +49 (0) 2963 61-449 E-Mail: motivepower@hoppecke.com

More information

Servo-pneumatic drive solution for welding guns. Top quality welding!

Servo-pneumatic drive solution for welding guns. Top quality welding! Servo-pneumatic drive solution for welding guns Sturdy and precise! Top quality welding! Highlights Extremely short cycle times High quality and outstanding reproducibility of the spot welds Excellent

More information

ROTARY MOTORIZED VALVES ROTARY MOTORIZED VALVES

ROTARY MOTORIZED VALVES ROTARY MOTORIZED VALVES ROTARY MOTORIZED VALVES 19 CONTENTS ROTARY MOTORIZED VALVES INTRODUCTION AND SELECTION GUIDES Series VRG130 DN 15 50, Kvs 0.4 40, PN10 33 34 35 Series VRG140 DN 15 50, Kvs.5 40, PN10 CHANGE-OVER/DIVERTING

More information

Rotary Blowers Omega Series Air delivery from 0.5 to 160 m³/min Pressure up to 1000 mbar, vacuum to -500 mbar

Rotary Blowers Omega Series Air delivery from 0.5 to 160 m³/min Pressure up to 1000 mbar, vacuum to -500 mbar www.kaeser.com Rotary Blowers Omega Series Air delivery from 0.5 to 160 m³/min Pressure up to 1000, vacuum to -500 KAESER Rotary Blowers Efficient and Durable Renowned throughout the world for their efficiency

More information

2009 / 2010 PRICES.

2009 / 2010 PRICES. 2009 / 2010 PRICES www.resol.com GB Welcome to RESOL RESOL factory I RESOL factory II Intelligent use of solar energy Since 1977 RESOL has been standing for intelligent solar thermal control technology.

More information