Circulation pumps. Wet rotor circulators and accessories. Heating Drinking water Solar Geothermy Condensate

Size: px
Start display at page:

Download "Circulation pumps. Wet rotor circulators and accessories. Heating Drinking water Solar Geothermy Condensate"

Transcription

1 Circulation pumps Wet rotor circulators and accessories eating Drinking water Solar Geothermy Condensate CATALOGUE

2 alm produces highly-efficient heating circulation pumps alm has been successfully developing and producing heating circulation pumps for over years. It started out manufacturing for renowned OEM customers before electing to develop and produce its own product range in the late s. Its proficiency in the development of innovative, market-oriented products is first and foremost reflected in the more than half a century of company history. Today, in the third generation, the circulation pumps segment plays a major part in the success of the company. This is particularly evident in the high level of creative innovation in recent years, with many new products in the field of high-efficiency pumps. alm places great demand on the quality of its products Modern production facilities and processes are just as much part of the corporate concept as well thought-out quality management. Internal testing facilities and ISO-certified quality management are indispensible factors of success. Long-standing customers value the high demands placed on the quality of the products and the flexibility with which alm meets custom requirements. alm is helping to shape the future as a reliable partner A company is only as good as each of its constituent parts. This is why motivated and experienced employees are a key element of success at alm. Flexibility and expertise head the list of priorities for being a reliable partner to our customers. Together with over employees, alm s objective is to make a lasting contribution to the future with its products. alm high efficiency pumps already fulfil the tightened requirements of the eco-design directive from until. The new EP Optimo features an LED display showing the modes of operation, the pressure head, the total electrical input power as well as error codes. As standard, it is delivered with a plug and with installation length mm also the insulation shell is included in delivery. No insulation shell is offered for mm installation length. For the EP Optimo Basic version, we ommit features such as display, insulation shell and plug but we fit a premounted cable in order to be able to offer a very well-priced model for different applications for which these features are neither required nor necessary. New in the delivery range are condensate pumps for gas and oil condensing boilers called Lift and a complete line of large EP Optimo L+ circulators. With this new high quality line of threaded and flanged circulators the whole replacement and new buildings demand for heating, air conditioning and refrigeration applications can be covered from / m to DN/ m. The new EP Optimo L+ complements the existing low cost series EP Optimo L which have been designed for the main types of applications with head or m. UPA UE EP EP Plus + EP EP Optimo Plus (N) EP BB EP-L EP Optimo L EP Optimo L+

3 Catalogue valid for non-eu countries Contents Page Contact General information Product range eating EP Optimo: igh efficiency pumps with LED display, electronically controlled EP Optimo Basic: igh efficiency pumps, electronically controlled EP Optimo L: igh efficiency pumps with LCD display, electronically controlled EP Optimo L+: igh efficiency pumps with LCD display, electronically controlled UPA: Standard heating circulation pumps, speed step switch (-step) LPA: Standard heating circulation pumps, speed step switch (-step) GPA: eating circulation pumps, speed step switch (-step), pressure head - m GPA flange: eating circulation pumps with flanged connection, speed step switch, pressure head up to m Drinking water EP Optimo (N): igh efficiency pumps with LED display and stainless steel housing, electronically controlled EP Optimo Basic (N): igh efficiency pumps with stainless steel housing, electronically controlled BUPA (N): Standard circulation pumps for drinking water with stainless steel housing BGPA (N): Circulation pumps for drinking water with stainless steel housing, pressure head - m Solar EP Optimo Solar: igh efficiency pumps with LED display, electronically controlled EP Optimo L Solar: igh efficiency pumps with LCD display, electronically controlled EP BB: Babelbox BB and EP PWM UPA Solar: Standard solar pumps, speed step switch (-step) LPA Solar: Solar pumps, speed step switch (-step) GPA Solar: Solar pumps, speed step switch (-step), pressure head - m Geothermy EP Optimo Geo: igh efficiency pumps with LED display, electronically controlled and protected against condensation EP Optimo L Geo: igh efficiency pumps with LCD display, electronically controlled and protected against condensation KGPA: Cold water circulation pumps (geothermy), pressure head - m Condensate Lift: Condensate pump for gas condensing boilers up to kw Lift Basic: Condensate pump for gas condensing boilers up to kw Lift NT: Condensate pump for oil condensing boilers with neutralization tank Accessories/Spare parts Screw connections Flange adaptors for pipe installation (flange) Insulation shell/insulation shell for cold water applications Plug Accessories/Spare parts for condensate pumps inverter controlled pumps Subject to technical changes without notice. Errors and ommissions excepted. The latest versions of our sales, delivery, and payment conditions as well as guarantee terms can be found on the internet at

4 Contact at alm Sales Mr Robin Pomreinke Phone: + - Fax: + - Order Management Ms Sabrina Wagner sabrina.wagner@halm.info Phone: + - Fax: + After Sales Mr Jürgen Albrecht juergen.albrecht@halm.info Phone: + - Fax: + - Mr Thomas Müller thomas.mueller@halm.info Phone: + - Fax: + Service hotline Phone: + -

5 General information alm type key EP Optimo -. G Pump types Nominal width pipe connection Pressure head in meters water column Speed switchable or electronically controlled Installation length (mm) Installation options Circulation pumps must be installed with a horizontal shaft. Construction alm circulation pumps are inline wet rotor circulators. They are maintenance-free and fitted with opposite-facing connecting nozzles of the same nominal width. The pump, motor and terminal box comprise one unit and are optimally matched with one another. A stainless steel can separates the rotor chamber and stator winding. It features static seals at both ends. Bearing Both bearings are made of oxide ceramic. This is particularly suitable because of its hardness, surface quality and corrosion resistance. They ensure smooth running and a long service life. Air cavities in the can well are evacuated via the hollow shaft. EEI The benchmark of the most efficient circulators is EEI.. All alm m high efficiency pumps fulfill the requirements for BEST in class.

6 igh efficiency pumps with LED display, electronically controlled EP Optimo series, product group Insulation shell With installation length mm included in delivery. valid for all alm m igh efficiency pumps Flow media heating water as per VDI pure, thin, non-aggressive and non-explosive, mineral oil-free media without solid or long-fibre components media with a max. viscosity of mm²/s operating data must be checked above % glycol Temperature range Ambient temperature: C to + C Temperature class: TF Media temperature: + C to + C Rate of flow: up to. m /h Pressure head: m/ m/ m Control range: - W/- W/- W Media temperature: + C to + C Installation length: and mm Threaded connection:, ½ and Protection class: IP Insulation class: F Nominal pressure: PN Control: pc + pv + fixed rpm EEI:. EP Optimo XX-. GXXX. EP Optimo XX-. GXXX. EP Optimo XX-. GXXX Product features manual start-up feature smooth running very low energy consumption integrated night economy feature air-vent screw LED display convenient operation + space-saving axially integrated terminal box automatic adjustment to pressure conditions cataphoretic coated pump housing pre-mounted, screwable angle entry-plug compact design Use The electronically controlled EP Optimo high efficiency wet rotor circulators with LED display and permanent magnet technology are designed for use in heating systems with variable or constant rate of flow. The cataphoretic coated pump housing is stainless. Mode of operation p control When thermostatic valves in systems with a long main supply heating pipe (likely for radiator systems) close, the total flow drops. This results in lower pipe resistance in this main pipe, which means the pump has to create lower head. Using proportional pressure mode PP ( ) is the best setting for such heating systems, as here the pump decreases head at lower flow. If the main supply heating pipe has not to be taken into consideration, because it is short or has its own pump (likely for underfloor heating systems with in mixing units integrated pumps), best mode to go with is constant pressure mode CP ( ). In such heating systems, it is important always to have constant pressure for the radiators or ufh-circuits, as the pressure loss in the main pipe is not considered and all other consumers are installed in parallel, which does not influence the maximum pressure loss. Ambient temperature To avoid condensation forming in the terminal box and stator, the media temperature must always be the same or higher than the ambient temperature. Ambient temp. Media temp. min. Media temp. max. Motor protection External motor protection is not required. Integrated night economy feature When the automatic night economy feature is activated, the circulation pump switches between normal mode and economy mode (characteristic curve MIN). The flow temperature is detected by a temperature sensor, the pump reacts accordingly. For this, it is necessary for the circulation pump to be installed in flow. Minimum inflow pressure Please determine the minimum inflow pressure for corresponding temperature from the following table. Media temperature < C > C Minimum inflow pressure. bar. bar Sound pressure level The sound pressure level is < db (A) Choice of control characteristic You can set different control modes via the potentiometer on the axial terminal box. Proportional pressure ( ), fixed speed ( ) and constant pressure ( ) can be adjusted continuously variable. The display indicates power consumption in [W] watts. Once the potentiometer is turned, the display first indicates mode of operation (PP, SC, CP), then value of set head in [m] meters. At the factory setting the potentiometer is in mode PP. Main areas of use eating, air-conditioning and industry systems as dual pipe system underfloor heating boiler/primary circuit storage charging circuit solar systems and heating pumps Materials Component Material Material no. Pump housing Grey-cast iron. Impeller Polyamide (PA - GF ) Shaft Bearing Bearing plate Stainless steel. Can Stainless steel.

7 igh efficiency pumps with LED display, electronically controlled EP Optimo series, product group Type Connection pipe Threaded connection Installation length (mm) Voltage (V) P (W) In (A) Weight (kg) Product no. EEI EP Optimo -. G ½ EP Optimo -. G ½ EP Optimo -. G ½ EP Optimo -. G ¼ EP Optimo -. G ¼ EP Optimo -. G ¼ EP Optimo -. G ½ EP Optimo -. G ½ EP Optimo -. G ½ EP Optimo -. G ¾ ¼ EP Optimo -. G ¾ ¼ EP Optimo -. G ¾ ¼ EP Optimo -. G ½ EP Optimo -. G ½ EP Optimo -. G ½ Constant pressure EP Optimo...-.-G Q (m / h) EP Optimo...-.-G Q (m / h) EP Optimo...-.-G Q (m³ / h) Proportional pressure EP Optimo...-.-G Q (m / h) EP Optimo...-.-G Q (m / h) EP Optimo...-.-G Q (m³ / h) Fixed rpm EP Optimo...-.-G Q (m / h) EP Optimo...-.-G Q (m / h) EP Optimo...-.-G Q (m³ / h) Dimensions Dimension illustration G Type L L L L EP Optimo / L L L L

8 igh efficiency pumps, electronically controlled EP Optimo Basic series, product group valid for all alm m igh efficiency pumps + Flow media heating water as per VDI pure, thin, non-aggressive and non-explosive, mineral oil-free media without solid or long-fibre components media with a max. viscosity of mm²/s operating data must be checked above % glycol Temperature range Ambient temperature: C to + C Temperature class: TF Media temperature: + C to + C Rate of flow: up to. m /h Pressure head: m/ m/ m Control range: - W/- W/ - W Media temperature: + C to + C Installation length: and mm Threaded connection:, ½ and Protection class: IP Insulation class: F Nominal pressure: PN Control: pc + pv + fixed rpm EEI:. EP Optimo Basic XX-. GXXX. EP Optimo Basic XX-. GXXX. EP Optimo Basic XX-. GXXX Product features manual start-up feature smooth running very low energy consumption integrated night economy feature air-vent screw convenient operation space-saving axially integrated terminal box automatic adjustment to pressure conditions cataphoretic coated pump housing pre-mounted cable ( m) compact design Use The electronically controlled EP Optimo Basic high efficiency wet rotor circulators with permanent magnet technology are designed for use in heating systems with variable or constant rate of flow. Mode of operation p control When thermostatic valves in systems with a long main supply heating pipe (likely for radiator systems) close, the total flow drops. This results in lower pipe resistance in this main pipe, which means the pump has to create lower head. Using proportional pressure mode PP ( ) is the best setting for such heating systems, as here the pump decreases head at lower flow. If the main supply heating pipe has not to be taken into consideration, because it is short or has its own pump (likely for underfloor heating systems with in mixing units integrated pumps), best mode to go with is constant pressure mode CP ( ). In such heating systems, it is important always to have constant pressure for the radiators or ufh-circuits, as the pressure loss in the main pipe is not considered and all other consumers are installed in parallel, which does not influence the maximum pressure loss. Ambient temperature To avoid condensation forming in the terminal box and stator, the media temperature must always be the same or higher than the ambient temperature. Ambient temp. Media temp. min. Media temp. max. Motor protection External motor protection is not required. Integrated night economy feature When the automatic night economy feature is activated, the circulation pump switches between normal mode and economy mode (characteristic curve MIN). The flow temperature is detected by a temperature sensor, the pump reacts accordingly. For this, it is necessary for the circulation pump to be installed in flow. Minimum inflow pressure Please determine the minimum inflow pressure for corresponding temperature from the following table. Media temperature < C > C Minimum inflow pressure. bar. bar Sound pressure level The sound pressure level is < db (A) Choice of control characteristic You can set different control modes via the potentiometer on the axial terminal box. Proportional pressure ( ), fixed speed ( ) and constant pressure ( ) can be adjusted continuously variable. Main areas of use eating, air-conditioning and industry systems as dual pipe system underfloor heating boiler/primary circuit storage charging circuit solar systems and heating pumps Materials Component Material Material no. Pump housing Grey-cast iron. Impeller Polyamide (PA - GF ) Shaft Bearing Bearing plate Stainless steel. Can Stainless steel.

9 igh efficiency pumps, electronically controlled Serie EP Optimo Basic, product group Type Connection pipe Threaded connection Installation length (mm) Voltage (V) P (W) In (A) Weight (kg) Product no. EEI EP Optimo Basic -. G ½ EP Optimo Basic -. G ½ EP Optimo Basic -. G ½ EP Optimo Basic -. G ¼ EP Optimo Basic -. G ¼ EP Optimo Basic -. G ¼ EP Optimo Basic -. G ½ EP Optimo Basic -. G ½ EP Optimo Basic -. G ½ EP Optimo Basic -. G ¾ ¼ EP Optimo Basic -. G ¾ ¼ EP Optimo Basic -. G ¾ ¼ EP Optimo Basic -. G ½ EP Optimo Basic -. G ½ EP Optimo Basic -. G ½ Constant pressure EP Optimo Basic...-.-G Q (m / h) EP Optimo Basic...-.-G Q (m / h)... EP Optimo Basic...-.-G.... Q (m³ / h) Proportional pressure.. EP Optimo Basic...-.-G Q (m / h) EP Optimo Basic...-.-G Q (m / h) EP Optimo Basic...-.-G Q (m³ / h) Fixed rpm..... EP Optimo Basic...-.-G Q (m / h) EP Optimo Basic...-.-G Q (m / h) EP Optimo Basic...-.-G Q (m³ / h) Dimensions Dimension illustration G Type L L L L EP Optimo Basic / L L L L

10 igh efficiency pumps with LCD display, electronically controlled EP Optimo L series, product group Insulation shell included in delivery. + Rate of flow: up to m /h Pressure head: m/ m Control range: - W/- W Media temperature: + C to + C Installation length: mm (thread)/ mm (flange) Threaded connection: ½ and (thread)/dn and DN (flange) Protection class: IP Insulation class: F Nominal pressure: PN EEI:. EP Optimo L XX-. GXXX. EP Optimo L XX-. GXXX Control: Internal: External: pc + pv + fixed rpm digital: PWM (characteristic lines for heating and solar per VDMA device paper ) frequency f nominal: - z voltage U nominal: - V power I: ma analogue: - V with cable break detection power I: ma impedance: kohm Omnibus fault message: Selector switch, potential-free, power max. A/ VAC Power supply for external unit: Voltage DC V, power max. ma Product features LCD display manual start-up feature smooth running very low energy consumption air-vent screw collective fault signal convenient operation axially integrated terminal box automatic adjustment to pressure conditions cataphoretic coated pump housing Use The electronically controlled EP Optimo L high efficiency wet rotor circulators with LCD display and permanent magnet technology are designed for use in heating systems with variable or constant rate of flow. The cataphoretic coated pump housing is stainless. Main areas of use eating, air-conditioning and industry systems as dual pipe system single pipe system underfloor heating boiler/primary circuit storage charging circuit solar systems and heating pumps Materials Component Material Material No. Pump body Grey-cast iron. Impeller Polyamide (PA - GF ) Shaft Bearing Bearing plate Stainless steel. Can Stainless steel. Flow media heating water as per VDI pure, thin, non-aggressive and non-explosive, mineral oil-free media without solid or long-fibre components media with a max. viscosity of mm²/s operating data must be checked above % glycol Temperature range Ambient temperature: C to + C Temperature class: TF Media temperature: + C to + C Ambient temperature To avoid condensation forming in the terminal box and stator, the media temperature must always be the same or higher than the ambient temperature. Ambient temp. Media temp. min. Media temp. max. Motor protection External motor protection is not required. Minimum inflow pressure Please determine the minimum inflow pressure for corresponding temperature from the following table. Media temperature < C > C Minimum inflow pressure. bar. bar Controls function You can make adjustments with the integrated control keys at the front. The LCD display shows the total electrical input power as a numeric value in [W] watts. Different icons at the top of the display show the function, setting and the modes of operation. Sound pressure level The sound pressure level is < db (A)

11 igh efficiency pumps with LCD display, electronically controlled EP Optimo L series, product group Type Connection pipe Threaded connection Flange Installation length (mm) Voltage (V) P (W) In (A) Weight (kg) Product no. EEI EP Optimo L -. G ½ EP Optimo L -. G ½ EP Optimo L -. G ¼ EP Optimo L -. G ¼ EP Optimo L -. G - - DN EP Optimo L -. G - - DN EP Optimo L -. G - - DN EP Optimo L -. G - - DN Proportional pressure Constant pressure Fixed rpm EP Optimo L...-. G EP Optimo L...-. G EP Optimo L...-. G step step step LOW LOW Q (m / h) Q (m / h) Q (m / h) Proportional pressure Constant pressure Fixed rpm EP Optimo L...-. G EP Optimo L...-. G step EP Optimo L...-. G step step LOW LOW Q (m / h) Q (m / h) Q (m / h) Dimensions Type L L L L EP Optimo L (thread) EP Optimo L (flange). Dimension illustration L L L L A

12 igh efficiency pumps with LCD display, electronically controlled EP Optimo L+ series, product group Insulation shell included in delivery lected power values (-% of maximum curve). The display shows alternately head, flow rate and power consumption. In cases of disturbances the icon SERVICE lights and additional error codes shown on the display enable a rapid troubleshooting. DIP switches located in the Circulator terminal box can be used optionally for locking against unauthorized adjustment and/or for an activation of the night setback mode. Materials Component Material Material no. Rate of flow: to m /h depending on model Pressure head: m/ m/ m/ m/ m Control range: to W depending on model Media temperature: - C (non freezing) to + C Installation length: to mm depending on model Circulator connection: ½ and (thread)/dn (flange) Protection class: IP Insulation class: F Nominal pressure: PN Control Internal: External: pc + pv + Eco Mode + fixed rpm analogue - V Start/Stop (bridged terminal ex works) Omnibus fault message: Selector switch, potential free. + Product features igh-efficiency wet running circulator with integrated automatic modes and additional eco mode for additional savings of approx. % compared to the best proportional pressure control. Convenient operation with multi-knob and dip switch. Optional night mode and locking against unauthorized adjustment. Clear display of function, setting and operating status via backlit icons and LCD display. Connection possibility of external control (- V, start / stop signal) and omnibus fault indication. Numerous integrated additional functions (autom. air ventilation, soft-start/inrush current limitation, anti blockage function, electronic motor protection against thermal overload). igh-quality manufacturing and standard insulation shells. Use The wet-running high-efficiency circulators EP Optimo L+ have an electronically commutated synchronous motor with permanent magnet rotor and a continuously variable differential pressure control. They are designed for use in circulating systems with variable or constant flow. The inline pump housings are resistant to corrosion by a cathodic electrodeposition coating. The EP Optimo L+ are designed for a static operating pressure of bar. Main areas of use eating, air conditioning/refrigeration, solar, heat pumps and industrial facilities as dual pipe system boiler and primary circuit single pipe system storage loading circuit panel systems like underfloor heating Pump housing Grey cast iron, KTL EN-GJL- Impeller Plastic with fiberglass PSU-GF Shaft Stainless steel. Bearing Flow media heating water as per VDI. pure, thin, non-aggressive and non-explosive, mineral oil-free media without solid or long-fibre components. media with a max. viscosity of mm /s. operating data must be checked above % glycol. Temperature range Ambient temperature: C to + C Temperature class: TF Media temperature: - C (non-freezing) to + C Ambient temperature To avoid condensation on the pump housing, the media temperature should always be equal to or higher than the ambient temperature (see table). Otherwise, as well as for temperatures from - C to + C, we recommend using a diffusion-tight insulation shell (see accessories). Ambient temperature Media temperature min. Media temperature max. C C C c C C C C C C C C C C C C C C Motor protection An external motor protection is not required. The integrated electronic motor protection automatically reduces the power at overload. Simultaneously, a warning appears on the display. Minimum inflow pressure To avoid cavitation noise and circulator damage the following minimum inlet pressure must be maintained at the pump suction nozzle. The values apply up to m above sea level. Otherwise, a surcharge of. bar per m time should be added. Media temperature < C > C bis < C Minimum inflow pressure, bar, bar Sound pressure level The sound pressure level is db (A). /Graphite Can Stainless steel. Insulation shell Polypropylen Controls function With the multi-function button, all settings can be made easily and quickly. The multifunction button consists of an outer dial for the selection of the desired mode and the power set values, and an internal activation pushbutton for the programming start and for the confirmation of the selected mode or the power set point. Lit symbols in the motor cap indicate which mode has been active or selected. By pressing the activation pushbutton for more than seconds, the pump is reset to factory default settings. LED segments located around the outer dial show blue enlightened for the se-

13 igh efficiency pumps with LCD display, electronically controlled EP Optimo L+ series, product group Model Connection pipe Threaded connection Flange Installation length (mm) Voltage (V) P (W) In (A) Weight (kg) Product no. EEI EP Optimo L+ -. G " ½" EP Optimo L+ -. G " ½" EP Optimo L+ -. G " ½" EP Optimo L+ -. G " ½" EP Optimo L+ -. G ¼" " EP Optimo L+ -. G ¼" " EP Optimo L+ -. G ¼" " EP Optimo L+ -. G ¼" " EP Optimo L+ -. G ¼" " EP Optimo L+ -. G EP Optimo L+ -. G EP Optimo L+ -. G EP Optimo L+ -. G EP Optimo L+ -. G EP Optimo L+ -. G EP Optimo L+ -. G EP Optimo L+ -. G EP Optimo L+ -. G EP Optimo L+ -. G EP Optimo L+ -. G Performance curves EP Optimo L+ -. G Fixed rpm and Eco Mode [m] Eco Mode Fixed rpm [m] Constant pressure and Proportional pressure Δp-v Δp-c EP Optimo L+ -. G Fixed rpm and Eco Mode [m] Eco Mode Fixed rpm Constant pressure and Proportional pressure [m] Δp-v Δp-c / - / / - / / - / / / Q [m³/h] Q [m³/h] / / / Q [m³/h] Q [m³/h] EP Optimo L+ -. G Fixed rpm and Eco mode Constant pressure and Proportional pressure EP Optimo L+ -. G Fixed rpm and Eco Mode Constant pressure and Proportional pressure [m] Eco Mode Fixed rpm [m] Δp-v Δp-c [m] Eco Mode Fixed rpm [m] Δp-v Δp-c / - / - / / / / Q [m³/h] Q [m³/h] - / - / / / / Q [m³/h] Q [m³/h] EP Optimo L+ -. G Fixed rpm and Eco Mode Constant pressure and Proportional pressure EP Optimo L+ -. G Fixed rpm and Eco Mode Constant pressure and Proportional pressure [m] Eco Mode Fixed rpm [m] Δp-v Δp-c [m] Eco Mode Fixed rpm [m] Δp-v Δp-c / - / / - / / - / / / Q [m³/h] Q [m³/h] / / / Q [m³/h] Q [m³/h]

14 igh efficiency pumps with LCD display, electronically controlled EP Optimo L+ series, product group EP Optimo L+ -. G Fixed rpm and Eco Mode Constant pressure and Proportional pressure EP Optimo L+ -. G Fixed rpm and Eco Mode Constant pressure and Proportional pressure [m] Eco Mode Fixed rpm [m] Δp-v Δp-c [m] Eco Mode Fixed rpm [m] Δp-v Δp-c / / / / - / - / / / - / - / Q [m³/h] Q [m³/h] / Q [m³/h] Q [m³/h] EP Optimo L+ -. G Fixed rpm and Eco Mode Constant pressure and Proportional pressure EP Optimo L+ -. G Fixed rpm and Eco Mode Constant pressure and Proportional pressure [m] Eco Mode Fixed rpm [m] Δp-v Δp-c [m] Eco Mode Fixed rpm [m] Δp-v Δp-c / / / - / - / / / - / - / Q [m³/h] Q [m³/h] / Q [m³/h] Q [m³/h] EP Optimo L+ -. G Fixed rpm and Eco Mode Constant pressure and Proportional pressure EP Optimo L+ -. G Fixed rpm and Eco Mode Constant pressure and Proportional pressure [m] Eco Mode Fixed rpm [m] Δp-v Δp-c [m] Eco Mode Fixed rpm [m] Δp-v Δp-c / - / / / / - / - / / Q [m³/h] Q [m³/h] / / / Q [m³/h] Q [m³/h] EP Optimo L+ -. G Fixed rpm and Eco Mode Constant pressure and Proportional pressure EP Optimo L+ -. G Fixed rpm and Eco Mode Constant pressure and Proportional pressure [m] Eco Mode Fixed rpm [m] Δp-v Δp-c [m] Eco Mode Fixed rpm [m] Δp-v Δp-c / - / - / / / Q [m³/h] Q [m³/h] / / / - / - / Q [m³/h] Q [m³/h] EP Optimo L+ -. G Fixed rpm and Eco Mode Constant pressure and Proportional pressure EP Optimo L+ -. G Fixed rpm and Eco Mode Constant pressure and Proportional pressure [m] Eco Mode Fixed rpm [m] Δp-v Δp-c [m] Eco Mode Fixed rpm [m] Δp-v Δp-c / / - / / / / Q [m³/h] Q [m³/h] / - / / / / / Q [m³/h] Q [m³/h]

15 igh efficiency pumps with LCD display, electronically controlled EP Optimo L+ series, product group EP Optimo L+ -. G EP Optimo L+ -. G Fixed rpm and Eco Mode Constant pressure and Proportional pressure [m] Eco Mode Fixed rpm Fixed rpm and Eco Mode [m] / / / / - / - Q [m³/h] Q [m³/h] EP Optimo L+ -. G Constant pressure and Proportional pressure Eco Mode Fixed rpm Q [m³/h] Q [m³/h] Constant pressure and Proportional pressure / / / Q [m³/h] / Q [m³/h] - / / - / / Δp-v Δp-c / / [m] - / - Eco Mode Fixed rpm [m] Δp-v Δp-c / / Fixed rpm and Eco Mode [m] / / EP Optimo L+ -. G Fixed rpm and Eco Mode [m] / Δp-v Δp-c [m] Eco Mode Fixed rpm Constant pressure and Proportional pressure [m] Δp-v Δp-c Q [m³/h] Q [m³/h] Dimensions (Flange Dimensions in mm) Combination PN Dimension illustration PN Flanges ØD Øk n x d ØD Øk n x d DN x Ø x Ø DN x Ø x Ø DN x Ø x Ø DN x Ø x Ø Dimension (Circulator dimensions in mm) F (mm) EP Optimo L+ -. G EP Optimo L+ -. G EP Optimo L+ -. G EP Optimo L+ -. G EP Optimo L+ -. G EP Optimo L+ -. G EP Optimo L+ -. G EP Optimo L+ -. G EP Optimo L+ -. G EP Optimo L+ -. G EP Optimo L+ -. G EP Optimo L+ -. G EP Optimo L+ -. G EP Optimo L+ -. G EP Optimo L+ -. G EP Optimo L+ -. G EP Optimo L+ -. G EP Optimo L+ -. G EP Optimo L+ -. G EP Optimo L+ -. G Dimension illustration (Threaded version) A F B R/G E E (mm) Dimension illustration (Flange version) A F G B DN E D (mm) D C (mm) C B (mm) D A (mm) C Model

16 Standard heating circulation pumps, speed step switch (-step) UPA series, product group Flow media heating water as per VDI pure, thin, non-aggressive and non-explosive, mineral oil-free media without solid or long-fibre components media with a max. viscosity of mm²/s operating data must be checked above % glycol Temperature range Ambient temperature: C to + C Temperature class: TF Media temperature: + C to + C Ambient temperature To avoid condensation forming in the terminal box and stator, the media temperature must always be the same or higher than the ambient temperature. Rate of flow: up to. m /h Pressure head: up to m Media temperature: + C to + C Installation length: and mm Threaded connection:, ½ and Protection class: IP Insulation class: Nominal pressure: PN Control: -step switch with manual speed selection Product features manual start-up feature energy-optimised space-saving axially integrated terminal box cataphoretic coated pump housing Use The UPA series circulation pumps are wet rotor circulators designed for use in heating systems with constant or weakly variable flow rates. With the -step rotary switch and the finely graded default programme, almost every working point on a system can be set economically. Main areas of use eating, air-conditioning and industry systems as dual pipe system single pipe systems underfloor heating boiler/primary circuit storage charging circuit Ambient temp. Media temp. min. Media temp. max. Motor protection External motor protection is not required. Speed switching The respective speed is set via a rotary switch integrated in the axial terminal box. Minimum inflow pressure Please determine the minimum inflow pressure for corresponding temperature from the following table. Media temperature < C C C Minimum inflow pressure. bar. bar. bar Sound pressure level The sound pressure level is < db (A) Materials Component Material Material no. Pump housing Grey-cast iron. Impeller Polyamide (PA - GF ) Shaft Bearing Bearing plate Stainless steel. Can Stainless steel.

17 Standard heating circulation pumps, speed step switch (-step) UPA series, product group Type Connection pipe Threaded connection Installation length (mm) Voltage (V) P (W) In (A) Weight (kg) Product no. UPA -. U ½ UPA -. U ½ UPA -. U ½ UPA -. U ½ UPA -. U ½ UPA -. U ¾ ¼ UPA -. U ¾ ¼ UPA -. U ¾ ¼ UPA -. U ¾ ¼ UPA -. U ¾" ¼ UPA -. U ½ UPA -. U ½ UPA -. U ½ UPA -. U ½ UPA -. U ½ UPA -. U ½ UPA -. U ½ UPA -. U ½ UPA -. U ½ UPA -. U ½ UPA -. U ¼ UPA -. U ¼ UPA -. U ¼ UPA -. U ¼ UPA -. U ¼ UPA...-. U. UPA...-. U. UPA...-. U Q (m /h) Q (m /h) Q (m /h) UPA...-. U... UPA...-. U Q (m /h) Q (m /h) G Dimensions Type L L L L UPA / Dimension illustration L L L L

18 Standard heating circulation pumps, speed step switch (-step) LPA series, product group Flow media heating water pure, thin, non-aggressive and non-explosive, mineral oil-free media without solid particles or fibres media with a max. viscosity of, - ft /s operating data must be checked above % glycol Temperature range Ambient temperature: C to + C Temperature class: TF Media temperature: - C to + C Ambient temperature To avoid condensation forming in the terminal box and stator, the media temperature must always be the same or higher than the ambient temperature. Rate of flow: up to m /h Pressure head: up to m Media temperature: - C to + C Installation lenght: mm Threaded connection: ½ und Protection class: IP Insulation class: Nominal pressure: PN Control: -step switch with manual speed selection Product features manual start-up feature smooth running convenient operation space-saving axially integrated terminal box compact design Use The LPA series circulation pumps are specially designed for heating systems in which large pressure heads and capacities are equally required. These circulation pumps are designed for use in heating systems with variable or constant flow rates. The LPA circulation pumps meet the energy efficiency standard class D. Main areas of use eating, air-conditioning and industry systems as dual pipe system boiler/primary circuit storage charging circuit Ambient temp. Media temp. min. Media temp. max. Motor protection External motor protection is not required. Speed switching Three speed, with manual selector. The respective speed is set via rotary switch integrated in the terminal board. Minimum inflow pressure Please determine the minimum inflow pressure for corresponding temperature from the following table. Media temperature < C C C Minimum inflow pressure. bar. bar. bar Sound pressure level The sound pressure level is < db (A) Materials Component Material Material no. Pump housing Grey-cast iron. Impeller Polyamide (PA - GF ) Shaft Bearing Bearing plate Stainless steel. Can Stainless steel.

19 Standard heating circulation pumps, speed step switch (-step) LPA series, product group Type Connection pipe Threaded connection Installation length (mm) Voltage (V) P (W) In (A) Weight (kg) Product no. LPA -. U ½ LPA -. U ¼ LPA...-. U Q (m /h),,,, Dimensions Type L L L L LPA Dimension illustration

20 eating circulation pumps, speed step switch (-step), pressure head - m GPA series, product group Flow media heating water as per VDI pure, thin, non-aggressive and non-explosive, mineral oil-free media without solid or long-fibre components media with a max. viscosity of mm²/s operating data must be checked above % glycol Temperature range Ambient temperature: C to + C Temperature class: TF Media temperature: + C to + C Ambient temperature To avoid condensation forming in the terminal box and stator, the media temperature must always be the same or higher than the ambient temperature. Rate of flow: up to m /h Pressure head: up to m Media temperature: + C to + C Installation length: mm Threaded connection: ½ and Protection class: IP Insulation class: Nominal pressure: PN Control: -step switch with manual speed selection Product features manual start-up feature smooth running convenient operation space-saving axially integrated terminal box compact design Use The GPA series circulation pumps are specially designed for heating systems in which large pressure heads and capacities are equally required. These circulation pumps are designed for use in heating systems with variable or constant flow rates. Main areas of use eating, air-conditioning and industry systems as dual pipe system underfloor heating boiler/primary circuit storage charging circuit Ambient temp. Media temp. min. Media temp. max. Motor protection External motor protection is not required. Speed switching The respective speed is set via a -step rotary switch integrated in the axial terminal box. Minimum inflow pressure Please determine the minimum inflow pressure for corresponding temperature from the following table. Media temperature < C C C Minimum inflow pressure. bar. bar. bar Sound pressure level The sound pressure level is < db (A) Materials Component Material Material no. Pump housing Grey-cast iron. Impeller Polypropylene (PP - GF ) Shaft Bearing Bearing plate Brass. Can Stainless steel.

21 eating circulation pumps, speed step switch (-step), pressure head - m GPA series, product group Type Connection pipe Threaded connection Installation length (mm) Voltage (V) P (W) In (A) Weight (kg) Product no. GPA -. U ½ GPA -. U ½ GPA -. U ½ GPA -. U ¼ GPA -. U ¼ GPA -. U ¼ GPA...-. U Q (m /h) GPA...-. U Q (m /h) GPA...-. U Q (m /h) Dimensions Type L L L L GPA. Dimension illustration G L L L L

22 eating circulation pumps with flanged connection, speed step switch, pressure head up to m GPA series, product group Flow media heating water as per VDI pure, thin, non-aggressive and non-explosive, mineral oil-free media without solid or long-fibre components media with a max. viscosity of mm²/s operating data must be checked above % glycol Temperature range Ambient temperature: C to + C Temperature class: TF Media temperature: + C to + C Ambient temperature To avoid condensation forming in the terminal box and stator, the media temperature must always be the same or higher than the ambient temperature. Rate of flow: up to m /h Pressure head: up to m Media temperature: + C to + C Installation lenght: mm Flanged connection: DN Protection class: IP Insulation class: Nominal pressure: PN Control: -step switch with manual speed selection Product features manual start-up feature smooth running convenient operation space-saving axially integrated terminal box compact design Use The GPA series circulation pumps are specially designed for heating systems in which large capacities are required. These circulation pumps are designed for use in heating systems with variable or constant flow rates. Main areas of use eating, air-conditioning and industry systems as dual pipe system underfloor heating boiler/primary circuit storage charging circuit Ambient temp. Media temp. min. Media temp. max. Motor protection External motor protection is not required. Speed switching Three speed, with manual selector. The respective speed is set via rotary switch integrated in the terminal board. Minimum inflow pressure Please determine the minimum inflow pressure for corresponding temperature from the following table. Media temperature < C C C Minimum inflow pressure. bar. bar. bar Sound pressure level The sound pressure level is < db (A) Materials Component Material Material no. Pump housing Grey-cast iron. Impeller Polyamide (PA - GF ) Shaft Bearing Bearing plate Stainless steel. Can Stainless steel.

23 FM- Stand.. Erstellt: M. Maier; Freigegeben:./. eating circulation pumps with flanged connection, speed step switch, pressure head up to m GPA series, product group Type Flanged connection Installation length (mm) Voltage (V) P (W) In (A) Weight (kg) Product no. GPA -. U (~)... - GPA -. U (~)... - GPA...-. U GPA...-. U Q (m /h) Q (m /h) Dimensions Type L L L L GPA Dimension illustration L L L L ISO -mk..

24 igh efficiency pumps with LED display and stainless steel housing, electronically controlled EP Optimo (N) series, T product group Insulation shell With installation length mm included in delivery. valid for all alm m igh efficiency pumps Flow media drinking water up to a temperature of C and a degree of hardness of d (temporary hardness) heating water as per VDI pure, thin, non-aggressive and non-explosive, mineral oil-free media without solid or long-fibre components media with a max. viscosity of mm²/s operating data must be checked above % glycol Rate of flow: up to. m /h Pressure head: m/ m Control range: - W/- W Media temperature: + C to + C Installation length:, and mm Threaded connection:, ½ and Protection class: IP Insulation class: F Nominal pressure: PN Control: pc + pv + fixed rpm EEI:. EP Optimo XX-. NXXX. EP Optimo XX-. NXXX Product features manual start-up feature smooth running very low energy consumption integrated night economy feature air-vent screw LED display convenient operation space-saving axially integrated terminal box + automatic adjustment to pressure conditions stainless steel pump housing pre-mounted, screwable angle entry-plug compact design optical fault indication optical display control mode Use The electronically controlled EP Optimo (N) high efficiency wet rotor circulators with LED display and permanent magnet technology are designed for use in heating systems as well as drinking water systems with variable or constant rate of flow. Mode of operation p control When thermostatic valves in systems with a long main supply heating pipe (likely for radiator systems) close, the total flow drops. This results in lower pipe resistance in this main pipe, which means the pump has to create lower head. Using proportional pressure mode PP ( ) is the best setting for such heating systems, as here the pump decreases head at lower flow. If the main supply heating pipe has not to be taken into consideration, because it is short or has its own pump (likely for underfloor heating systems with in mixing units integrated pumps or drinking water systems), best mode to go with is constant pressure mode CP ( ). In such heating systems, it is important always to have constant pressure for the radiators or ufh-circuits, as the pressure loss in the main pipe is not considered and all other consumers are installed in parallel, which does not influence the maximum pressure loss. Temperature range Ambient temperature: C to + C Temperature class: TF Media temperature: + C to + C Ambient temperature To avoid condensation forming in the terminal box and stator, the media temperature must always be the same or higher than the ambient temperature. Ambient temp. Media temp. min. Media temp. max. Motor protection External motor protection is not required. Integrated night economy feature When the automatic night economy feature is activated, the circulation pump switches between normal mode and economy mode (characteristic curve MIN). The flow temperature is detected by a temperature sensor, the pump reacts accordingly. For this, it is necessary for the circulation pump to be installed in flow. Minimum inflow pressure Please determine the minimum inflow pressure for corresponding temperature from the following table. Media temperature < C > C Minimum inflow pressure. bar. bar Sound pressure level The sound pressure level is < db (A) Choice of control characteristic You can set different control modes via the potentiometer on the axial terminal box. Proportional pressure ( ), fixed speed ( ) and constant pressure ( ) can be adjusted continuously variable. The display indicates power consumption in [W] watts. Once the potentiometer is turned, the display first indicates mode of operation (PP, SC, CP), then value of set head in [m] meters. At the factory setting the potentiometer is in mode PP. Main areas of use drinking water systems Materials Component Material Material no. Pump housing Stainless steel. Impeller Polyamide (PA - GF ) Shaft Bearing Bearing plate Stainless steel. Can Stainless steel.

25 igh efficiency pumps with LED display and stainless steel housing, electronically controlled EP Optimo (N) series, T product group Type Connection pipe Threaded connection Installation length (mm) Voltage (V) P (W) In (A) Weight (kg) Product no. EEI EP Optimo -. N ½ EP Optimo -. N ½ EP Optimo -. N ½ EP Optimo -. N ½ EP Optimo -. N ¾ ¼ EP Optimo -. N ¾ ¼ EP Optimo -. N ½ EP Optimo -. N ½ Constant pressure EP Optimo...-.-N Q (m / h) EP Optimo...-.-N Q (m / h) Proportional pressure EP Optimo...-.-N Q (m / h) EP Optimo...-.-N Q (m / h) Fixed rpm EP Optimo...-.-N Q (m / h) EP Optimo...-.-N Q (m / h) Dimensions Type L L L L EP Optimo (N) // Dimension illustration G L L L L

26 igh efficiency pumps with stainless steel housing, electronically controlled EP Optimo Basic (N) series, T product group Rate of flow: up to. m /h Pressure head: m/ m Control range: - W/- W Media temperature: + C to + C Installation length:, and mm Threaded connection:, ½ and Protection class: IP Insulation class: F Nominal pressure: PN Control: pc + pv + fixed rpm EEI:. EP Optimo Basic XX-. NXXX. EP Optimo Basic XX-. NXXX Product features manual start-up feature smooth running very low energy consumption integrated night economy feature air-vent screw convenient operation valid for all alm m igh efficiency pumps + space-saving axially integrated terminal box automatic adjustment to pressure conditions stainless steel pump housing pre-mounted cable ( m) compact design Use The electronically controlled EP Optimo Basic (N) high efficiency wet rotor circulators with permanent magnet technology are designed for use in heating systems as well as drinking water systems with variable or constant rate of flow. Mode of operation p control When thermostatic valves in systems with a long main supply heating pipe (likely for radiator systems) close, the total flow drops. This results in lower pipe resistance in this main pipe, which means the pump has to create lower head. Using proportional pressure mode PP ( ) is the best setting for such heating systems, as here the pump decreases head at lower flow. If the main supply heating pipe has not to be taken into consideration, because it is short or has its own pump (likely for underfloor heating systems with in mixing units integrated pumps or drinking water systems), best mode to go with is constant pressure mode CP ( ). In such heating systems, it is important always to have constant pressure for the radiators or ufh-circuits, as the pressure loss in the main pipe is not considered and all other consumers are installed in parallel, which does not influence the maximum pressure loss. Flow media drinking water up to a temperature of C and a degree of hardness of d (temporary hardness) heating water as per VDI pure, thin, non-aggressive and non-explosive, mineral oil-free media without solid or long-fibre components media with a max. viscosity of mm²/s operating data must be checked above % glycol Temperature range Ambient temperature: C to + C Temperature class: TF Media temperature: + C to + C Ambient temperature To avoid condensation forming in the terminal box and stator, the media temperature must always be the same or higher than the ambient temperature. Ambient temp. Media temp. min. Media temp. max. Motor protection External motor protection is not required. Integrated night economy feature When the automatic night economy feature is activated, the circulation pump switches between normal mode and economy mode (characteristic curve MIN). The flow temperature is detected by a temperature sensor, the pump reacts accordingly. For this, it is necessary for the circulation pump to be installed in flow. Minimum inflow pressure Please determine the minimum inflow pressure for corresponding temperature from the following table. Media temperature < C > C Minimum inflow pressure. bar. bar Sound pressure level The sound pressure level is < db (A) Choice of control characteristic You can set different control modes via the potentiometer on the axial terminal box. Proportional pressure ( ), fixed speed ( ) and constant pressure ( ) can be adjusted continuously variable. Main areas of use drinking water systems Materials Component Material Material no. Pump housing Stainless steel. Impeller Polyamide (PA - GF ) Shaft Bearing Bearing plate Stainless steel. Can Stainless steel.

27 igh efficiency pumps with stainless steel housing, electronically controlled EP Optimo Basic (N) series, T product group Type Connection pipe Threaded connection Installation length (mm) Voltage (V) P (W) In (A) Weight (kg) Product no. EEI EP Optimo Basic -. N ½ EP Optimo Basic -. N ½ EP Optimo Basic -. N ½ EP Optimo Basic -. N ½ EP Optimo Basic -. N ¾ ¼ EP Optimo Basic -. N ¾ ¼ EP Optimo Basic -. N ½ EP Optimo Basic -. N ½ Constant pressure EP Optimo Basic...-.-N Q (m / h) EP Optimo Basic...-.-N Q (m / h) Proportional pressure EP Optimo Basic...-.-N Q (m / h) EP Optimo Basic...-.-N Q (m / h) Fixed rpm EP Optimo Basic...-.-N Q (m / h) EP Optimo Basic...-.-G Q (m / h) Dimensions Type L L L L EP Optimo Basic (N) / Dimension illustration G L L L L

28 Standard circulation pumps for drinking water with stainless steel housing BUPA (N) series, T product group Rate of flow: up to. m / h Pressure head: up to m Media temperature: + C to + C Installation length:, and mm Threaded connection:, ¼ and ½ Protection class: IP Insulation class: Nominal pressure: PN Control: -step switch with manual speed selection Product features manual start-up feature space-saving axially integrated terminal box Use The BUPA (N) series circulation pumps are wet rotor circulators designed for use in drinking water systems with constant or weakly variable flow rates. They feature a corrosion-resistant pump housing in stainless steel and are thus suitable for use in drinking water circulation systems. Ambient temperature To avoid condensation forming in the terminal box and stator, the media temperature must always be the same or higher than the ambient temperature. Ambient temp. Media temp. min. Media temp. max. Motor protection External motor protection is not required. Materials Component Material Material no. Pump housing Stainless steel. Impeller PSU - GF Speed switching The respective speed is set via a rotary switch integrated in the axial terminal box. Minimum inflow pressure Please determine the minimum inflow pressure for corresponding temperature from the following table. Shaft Bearing Bearing plate Stainless steel. Media temperature < C C C Minimum inflow pressure. bar. bar. bar Can Stainless steel. Temperature range Ambient temperature: C to + C Temperature class: TF Media temperature: + C to + C Sound pressure level The sound pressure level is < db (A) Flow media drinking water up to a temperature of C and a degree of hardness of d (temporary hardness) heating water as per VDI pure, thin, non-aggressive and non-explosive, mineral oil-free media without solid or long-fibre components media with a max. viscosity of mm²/s

29 Standard circulation pumps for drinking water with stainless steel housing BUPA (N) series, T product group Type Connection pipe Threaded connection Installation length (mm) Voltage (V) P (W) In (A) Weight (kg) Product no. BUPA -. N ½ BUPA -. N ½ BUPA -. N ½ BUPA -. N ½ BUPA -. N ½ BUPA -. N ½ BUPA -. N ¾ ¼ BUPA -. N ¾ ¼ BUPA -. N ¾ ¼ BUPA -. N ½ BUPA -. N ½ BUPA -. N ½ BUPA...-. N. BUPA...-. N Q (m / h) Q (m / h) BUPA...-. N..... Q (m / h) Dimensions Type L L L L BUPA (N) // Dimension illustration G L L L L

30 Circulation pumps for drinking water with stainless steel housing, pressure head - m BGPA (N) series, T product group Rate of flow: up to. m /h Pressure head: up to m Media temperature: + C to + C Installation length: mm Threaded connection: ¼ and ½ Protection class: IP Insulation class: Nominal pressure: PN Control: -step switch with manual speed selection Product features manual start-up feature space-saving axially integrated terminal box pump housing in stainless steel Use The BGPA (N) series circulation pumps are wet rotor circulators designed for use in drinking water systems with a flow rate of > m /h. They feature a corrosionresistant housing in stainless steel and are thus designed for use in drinking water circulation systems. Ambient temperature To avoid condensation forming in the terminal box and stator, the media temperature must always be the same or higher than the ambient temperature. Ambient temp. Media temp. min. Media temp. max. Motor protection External motor protection is not required. Materials Component Material Material no. Pump housing Stainless steel. Impeller Polypropylene (PP - GF ) Speed switching The respective speed is set via a rotary switch integrated in the axial terminal box. Minimum inflow pressure Please determine the minimum inflow pressure for corresponding temperature from the following table. Shaft Bearing Media temperature < C C C Minimum inflow pressure. bar. bar. bar Bearing plate Brass. Can Stainless steel. Sound pressure level The sound pressure level is < db (A) Temperature range Ambient temperature: C to + C Temperature class: TF Media temperature: + C to + C Flow media drinking water up to a temperature of C and a degree of hardness of d (temporary hardness) heating water as per VDI pure, thin, non-aggressive and non-explosive, mineral oil-free media without solid or long-fibre components media with a max. viscosity of mm²/s

31 Circulation pumps for drinking water with stainless steel housing, pressure head - m BGPA (N) series, T product group Type Connection pipe Threaded connection Installation length (mm) Voltage (V) P (W) In (A) Weight (kg) Product no. BGPA -. N ¾ ¼ BGPA -. N ¾ ¼ BGPA -. N ¾ ¼ BGPA -. N ¾ ¼ BGPA -. N ½ BGPA -. N ½ BGPA -. N ½ BGPA -. N ½ BGPA...-. N Q (m / h) BGPA...-. N Q (m / h) BGPA...-. N Q (m / h) BGPA...-. N Q (m / h) Dimensions Type L L L L BGPA (N). Dimension illustration G L L L L

32 igh efficiency pumps with LED display, electronically controlled EP Optimo Solar series, S product group Insulation shell With installation length mm included in delivery. + Rate of flow: up to. m /h Pressure head: m/ m Control range: - W/- W Media temperature: + C to + C Installation length: and mm Threaded connection:, ½ and Protection class: IP Insulation class: F Nominal pressure: PN Control: pc + pv + fixed rpm EEI:. EP Optimo Solar XX-. GXXX. EP Optimo Solar XX-. GXXX valid for all alm m igh efficiency pumps Flow media heating water as per VDI pure, thin, non-aggressive and non-explosive, mineral oil-free media without solid or long-fibre components media with a max. viscosity of mm²/s operating data must be checked above % glycol Temperature range Ambient temperature: C to + C Temperature class: TF Media temperature: + C to + C Ambient temperature To avoid condensation forming in the terminal box and stator, the media temperature must always be the same or higher than the ambient temperature. Ambient temp. Media temp. min. Media temp. max. Motor protection External motor protection is not required. Product features manual start-up feature smooth running very low energy consumption integrated night economy feature air-vent screw LED display convenient operation space-saving axially integrated terminal box automatic adjustment to pressure conditions cataphoretic coated pump housing pre-mounted, screwable angle entry-plug compact design Use The electronically controlled EP Optimo Solar high efficiency wet rotor circulators with LED display and permanent magnet technology are designed for use in solar systems with variable or constant rate of flow. The cataphoretic coated pump housing is stainless. Mode of operation p control When thermostatic valves in systems with a long main supply heating pipe (likely for radiator systems) close, the total flow drops. This results in lower pipe resistance in this main pipe, which means the pump has to create lower head. Using proportional pressure mode PP ( ) is the best setting for such heating systems, as here the pump decreases head at lower flow. If the main supply heating pipe has not to be taken into consideration, because it is short or has its own pump (likely for underfloor heating systems with in mixing units integrated pumps or solar systems), best mode to go with is constant pressure mode CP ( ). In such heating systems, it is important always to have constant pressure for the radiators or ufh-circuits, as the pressure loss in the main pipe is not considered and all other consumers are installed in parallel, which does not influence the maximum pressure loss. Integrated night economy feature When the automatic night economy feature is activated, the circulation pump switches between normal mode and economy mode (characteristic curve MIN). The flow temperature is detected by a temperature sensor, the pump reacts accordingly. For this, it is necessary for the circulation pump to be installed in flow. Minimum inflow pressure Please determine the minimum inflow pressure for corresponding temperature from the following table. Media temperature < C > C Minimum inflow pressure. bar. bar Sound pressure level The sound pressure level is < db (A) Choice of control characteristic You can set different control modes via the potentiometer on the axial terminal box. Proportional pressure ( ), fixed speed ( ) and constant pressure ( ) can be adjusted continuously variable. The display indicates power consumption in [W] watts. Once the potentiometer is turned, the display first indicates mode of operation (PP, SC, CP), then value of set head in [m] meters. At the factory setting the potentiometer is in mode PP. Main areas of use solar systems Materials Component Material Material no. Pump housing Grey-cast iron. Impeller Polyamide (PA - GF ) Shaft Bearing Bearing plate Stainless steel. Can Stainless steel.

33 igh efficiency pumps with LED display, electronically controlled EP Optimo Solar series, S product group Type Connection pipe Threaded connection Installation length (mm) Voltage (V) P (W) In (A) Weight (kg) Product no. EEI EP Optimo Solar -. G ½ EP Optimo Solar -. G ½ EP Optimo Solar -. G ¼ EP Optimo Solar -. G ¼ EP Optimo Solar -. G ½ EP Optimo Solar -. G ½ EP Optimo Solar -. G ¾ ¼ EP Optimo Solar -. G ¾ ¼ EP Optimo Solar -. G ½ EP Optimo Solar -. G ½ Constant pressure EP Optimo Solar...-.-G Q (m / h) EP Optimo Solar...-.-G Q (m / h) Proportional pressure EP Optimo Solar...-.-G Q (m / h) EP Optimo Solar...-.-G Q (m / h) Fixed rpm EP Optimo Solar...-.-G Q (m / h) EP Optimo Solar...-.-G Q (m / h) Dimensions Dimension illustration G Type L L L L EP Optimo Solar / L L L L

34 igh efficiency pumps with LCD display, electronically controlled EP Optimo L Solar series, S product group Insulation shell included in delivery. + Rate of flow: up to m /h Pressure head: m/ m Control range: - W/- W Media temperature: + C to + C Installation length: mm (thread)/ mm (flange) Threaded connection: ½ and (thread)/dn and DN (flange) Protection class: IP Insulation class: F Nominal pressure: PN EEI:. EP Optimo L XX-. GXXX. EP Optimo L XX-. GXXX Control: Internal: External: pc + pv + fixed rpm digital: PWM (characteristic lines for heating and solar per VDMA device paper ) frequency f nominal: - z voltage U nominal: - V power I: ma analogue: - V with cable break detection power I: ma impedance: kohm Omnibus fault message: Selector switch, potential-free, power max. A/ VAC Power supply for external unit: Voltage DC V, power max. ma Product features LCD display manual start-up feature smooth running very low energy consumption air-vent screw collective fault signal convenient operation axially integrated terminal box automatic adjustment to pressure conditions cataphoretic coated pump housing Use The electronically controlled EP Optimo L Solar high efficiency wet rotor circulators with LCD display and permanent magnet technology are designed for use in heating systems with variable or constant rate of flow. The cataphoretic coated pump housing is stainless. Main areas of use solar systems Controls Function You can make adjustments with the integrated control keys at the front. The LCD display shows the total electrical input power as a numeric value in [W] watts. Different icons at the top of the display show the function, setting and the modes of operation. Materials Component Material Material No. Pump body Grey-cast iron. Impeller Polyamide (PA - GF ) Shaft Bearing Bearing plate Stainless steel. Can Stainless steel. Flow media heating water as per VDI pure, thin, non-aggressive and non-explosive, mineral oil-free media without solid or long-fibre components media with a max. viscosity of mm²/s operating data must be checked above % glycol Temperature range Ambient temperature: C to + C Temperature class: TF Media temperature: + C to + C Ambient temperature To avoid condensation forming in the terminal box and stator, the media temperature must always be the same or higher than the ambient temperature. Ambient temp. Media temp. min. Media temp. max. Motor protection External motor protection is not required. Minimum inflow pressure Please determine the minimum inflow pressure for corresponding temperature from the following table. Media temperature < C > C Minimum inflow pressure. bar. bar Sound pressure level The sound pressure level is < db (A)

35 igh efficiency pumps with LCD display, electronically controlled EP Optimo L Solar series, S product group Type Connection pipe Threaded connection Flange Installation length (mm) Voltage (V) P (W) In (A) Weight (kg) Product no. EEI EP Optimo L Solar -. G ½ EP Optimo L Solar -. G ½ EP Optimo L Solar -. G ¼ EP Optimo L Solar -. G ¼ EP Optimo L Solar -. G - - DN EP Optimo L Solar -. G - - DN EP Optimo L Solar -. G - - DN EP Optimo L Solar -. G - - DN Proportional pressure Constant pressure Fixed rpm EP Optimo L Solar...-. G EP Optimo L Solar...-. G EP Optimo L Solar...-. G step step step LOW LOW Q (m / h) Q (m / h) Q (m / h) Proportional pressure Constant pressure Fixed rpm EP Optimo L Solar...-. G EP Optimo L Solar...-. G step EP Optimo L Solar...-. G step LOW Q (m / h) LOW Q (m / h) step Q (m / h) Dimensions Type L L L L EP Optimo L (thread) EP Optimo L (flange). Dimension illustration L L L L A

36 EP BB Babelbox BB and EP PWM, S product group Supply voltage: V Power input:. W Signal input leading edge: - V Signal input trailing edge: - V Signal input wave packet: - V, z Signal input power consumption:. ma PWM output: V DC, ma Frequency: z Ambient temperature: C to + C Cable connection input: x M Dimensions: x x mm Weight:. kg Use The Babelbox BB is designed for use in heating systems in which an on-site controller pulses a standard pump via the power line and this pump is to be replaced by a high-efficiency pump. igh-efficiency pumps do not react to a pulsed power line and therefore cannot simply substitute for a standard pump. Interposing the Babelbox BB solves this issue while retaining the control functions of the system. Mode of operation The BB automatically detects if an on-site controller is pulsing the power line via a wave packet or is outputting leading or trailing edge voltage. The BB converts this into a PWM signal which is identified by the alm PWM pump. Just like the standard pump previously, its power is also then controlled. An integrated LED shows the presence of voltage from the on-site controller. Main areas of use All applications in which a standard pump controlled externally by the power line is to be replaced by a high-efficiency pump. Return flow boost Solar installation Differential temperature controlled underfloor heating Storage charging circuit Freshwater station (suitability should be checked with the manufacturer due to the highly sensitive controlled system) Installation Stable cable bushings and elevator terminals enable easy installation. The BB must be connected to V voltage, with the PWM pump and the pulsed power line. Fully automatic detection of the input signal means no further settings need be adjusted. Motor (high efficient ECM technology) Power supply nominal: - V, - z Power consumption: Version m (- W); Version m (- W) Power consumption stand-by PWM:. W PWM connection PWM input: Frequency f nominal: Voltage U nominal: Power PWM to V: Power PWM to V: Insulation voltage optocoupler: - z - V max. ma max. ma VRMS (T ein / T pwm ) x Standards //EG, //EG, //EG EN -, EN --, EN -:+A:, EN -:+A.+A: EN -:, EN --:, EN, EN --, EN --, EN -, EN - The Babelbox BB solution! It was previously not possible to replace standard heating pumps driven by wave packet, leading or trailing edge control with high-efficiency pumps. For the first time, this can now be done with the Babelbox BB. Fully automatic signal detection! Typical high-efficiency pumps require a V constant voltage supply. If, however, a high-efficiency pump is connected to a variable power voltage supply (solar controller, freshwater station controller, charging controller etc.), it reacts neither to a wave packet nor leading edge control as desired. This is where the Babelbox BB from alm comes in. It independently and fully automatically detects which signal is being output by the controller of the standard pump and converts it into a PWM signal which can be understood by the high-efficiency pump, controlling the latter in just the same way as the previously installed standard pump. The voltage supply for the high-efficiency pump itself comes from a separate V connection.

37 EP BB Babelbox BB and EP PWM, S product group Type Connection pipe Threaded connection Installation length (mm) P (W) In (A) Weight (kg) Product no. EP BB -. G " ½" EP BB -. G " ½" EP BB -. G ¼" " EP BB -. G ¼" " EP BB -. G ½" " EP BB -. G ½" " EP BB -. G " ½" EP BB -. G " ½" EP PWM...-.-G Q (m / h) EP PWM...-.-G Q (m / h).,.....,

38 Standard solar pumps, speed step switch (-step) UPA Solar series, S product group Flow media heating water as per VDI pure, thin, non-aggressive and non-explosive, mineral oil-free media without solid or long-fibre components media with a max. viscosity of mm²/s operating data must be checked above % glycol Temperature range Ambient temperature: C to + C Temperature class: TF Media temperature: + C to + C (short-term up to C) Ambient temperature To avoid condensation forming in the terminal box and stator, the media temperature must always be the same or higher than the ambient temperature. Rate of flow: up to. m /h Pressure head: up to. m Media temperature: + C to + C (short-term up to C) Installation length: and mm Threaded connection:, ½ and Protection class: IP Insulation class: Nominal pressure: PN Control: -step switch with manual speed selection Product features manual start-up feature energy-optimised space-saving axially integrated terminal box cataphoretic coated pump housing Use The UPA Solar pumps are wet rotor circulators designed for primary circuits of solar systems. Materials Component Material Material no. Pump housing Grey-cast iron. Impeller Polyamide (PA - GF ) Shaft Bearing Bearing plate Stainless steel. Can Stainless steel. Ambient temp. Media temp. min. Media temp. max. Motor protection External motor protection is not required. Speed switching The respective speed is set via a rotary switch integrated in the axial terminal box. Minimum inflow pressure Please determine the minimum inflow pressure for corresponding temperature from the following table. Media temperature < C C C Minimum inflow pressure. bar. bar. bar Sound pressure level The sound pressure level is < db (A)

39 Standard solar pumps, speed step switch (-step) UPA Solar series, S product group Type Connection pipe Threaded connection Installation length (mm) Voltage (V) P (W) In (A) Weight (kg) Product no. UPA Solar -. U ½ UPA Solar -. U ½ UPA Solar -. U ¾ ¼ UPA Solar -. U ¾ ¼ UPA Solar -. U ½ UPA Solar -. U ½ UPA Solar -. U ½ UPA Solar -. U ½ UPA Solar -. U ¼ UPA Solar -. U ¼ UPA...-. U.. UPA...-. U Q (m /h) Q (m /h) Dimensions Type L L L L UPA Solar / Dimension illustration G L L L L

40 Solar pumps, speed step switch (-step) LPA Solar series, S product group Flow media heating water pure, thin, non-aggressive and non-explosive, mineral oil-free media without solid particles or fibres media with a max. viscosity of, - ft /s operating data must be checked above % glycol Temperature range Ambient temperature: C to + C Temperature class: TF Media temperature: - C to + C Ambient temperature To avoid condensation forming in the terminal box and stator, the media temperature must always be the same or higher than the ambient temperature. Rate of flow: up to m /h Pressure head: up to m Media temperature: - C to + C Installation lenght: mm Threaded connection: ½ und Protection class: IP Insulation class: Nominal pressure: PN Control: -step switch with manual speed selection Product features manual start-up feature smooth running convenient operation space-saving axially integrated terminal box compact design Use The LPA Solar pumps are specially designed for primary circuits of solar systems. Materials Component Material Material no. Pump housing Grey-cast iron. Impeller Polyamide (PA - GF ) Shaft Bearing Bearing plate Stainless steel. Can Stainless steel. Ambient temp. Media temp. min. Media temp. max. Motor protection External motor protection is not required. Speed switching Three speed, with manual selector. The respective speed is set via a -step rotary switch integrated in the terminal board. Minimum inflow pressure Please determine the minimum inflow pressure for corresponding temperature from the following table. Media temperature < C C C Minimum inflow pressure. bar. bar. bar Sound pressure level The sound pressure level is < db (A)

41 Solar pumps, speed step switch (-step) LPA Solar series, S product group Type Connection pipe Threaded connection Installation length (mm) Voltage (V) P (W) In (A) Weight (kg) Product no. LPA Solar -. U ½ LPA Solar -. U ¼ LPA...-. U,,,, Q (m /h) Dimensions Type L L L L LPA Solar Dimension illustration

42 Solar pumps, speed step switch (-step), pressure head - m GPA Solar series, S product group Flow media heating water as per VDI pure, thin, non-aggressive and non-explosive, mineral oil-free media without solid or long-fibre components media with a max. viscosity of mm²/s operating data must be checked above % glycol Temperature range Ambient temperature: C to + C Temperature class: TF Media temperature: + C to + C Ambient temperature To avoid condensation forming in the terminal box and stator, the media temperature must always be the same or higher than the ambient temperature. Rate of flow: up to m /h Pressure head: up to m Media temperature: + C to + C Installation length: mm Threaded connection: ½ and Protection class: IP Insulation class: Nominal pressure: PN Control: -step switch with manual speed selection Product features manual start-up feature smooth running convenient operation space-saving axially integrated terminal box compact design Use The GPA Solar pumps are wet rotor circulators and specially designed for primary circuits of solar systems. Materials Component Material Material no. Pump housing Grey-cast iron. Impeller Polypropylene (PP - GF ) Shaft Bearing Bearing plate Brass. Can Stainless steel. Ambient temp. Media temp. min. Media temp. max. Motor protection External motor protection is not required. Speed switching The respective speed is set via a -step rotary switch integrated in the axial terminal box. Minimum inflow pressure Please determine the minimum inflow pressure for corresponding temperature from the following table. Media temperature < C C C Minimum inflow pressure. bar. bar. bar Sound pressure level The sound pressure level is < db (A)

43 Solar pumps, speed step switch (-step), pressure head - m GPA Solar series, S product group Type Connection pipe Threaded connection Installation length (mm) Voltage (V) P (W) In (A) Weight (kg) Product no. GPA Solar -. U ½ GPA Solar -. U ½ GPA Solar -. U ½ GPA Solar -. U ¼ GPA Solar -. U ¼ GPA Solar -. U ¼ GPA...-. U Q (m /h) GPA...-. U Q (m /h) GPA...-. U Q (m /h) Dimensions Type L L L L GPA Solar. Dimension illustration G L L L L

44 igh efficiency pumps with LED display, electronically controlled and protected against condensation EP Optimo Geo series, G product group Insulation shell With installation length mm included in delivery. Rate of flow: up to. m / h Pressure head: m/ m Control range: - W/- W Media temperature: - C to + C Installation length: and mm Threaded connection:, ½ and Protection class: IP Insulation class: F Nominal pressure: PN Control: pc + pv + fixed rpm EEI:. EP Optimo Geo XX-. GXXX. EP Optimo Geo XX-. GXXX valid for all alm m igh efficiency pumps + Flow media heating water as per VDI pure, thin, non-aggressive and non-explosive, mineral oil-free media without solid or long-fibre components media with a max. viscosity of mm²/s operating data must be checked above % glycol Temperature range Ambient temperature: C to + C Temperature class: TF Media temperature: - C to + C Ambient temperature To avoid condensation forming in the terminal box and stator, the media temperature must always be the same or higher than the ambient temperature. Ambient temp. Media temp. min. Media temp. max. Motor protection External motor protection is not required. Product features manual start-up feature smooth running very low energy consumption integrated night economy feature air-vent screw LED display convenient operation space-saving axially integrated terminal box automatic adjustment to pressure conditions cataphoretic coated pump housing pre-mounted, screwable angle entry-plug compact design Use The electronically controlled EP Optimo Geo high efficiency wet rotor circulators with LED display and permanent magnet technology are designed for use in heating and cold water circulation systems with variable or constant rate of flow. The motor integrity offers a sealed winding protection from ingress of condensation. The cataphoretic coated pump housing is stainless. Mode of operation p control When thermostatic valves in systems with a long main supply heating pipe (likely for radiator systems) close, the total flow drops. This results in lower pipe resistance in this main pipe, which means the pump has to create lower head. Using proportional pressure mode PP ( ) is the best setting for such heating systems, as here the pump decreases head at lower flow. If the main supply heating pipe has not to be taken into consideration, because it is short or has its own pump (likely for underfloor heating systems with in mixing units integrated pumps) or heating pumps, best mode to go with is constant pressure mode CP ( ). In such heating systems, it is important always to have constant pressure for the radiators or ufh-circuits, as the pressure loss in the main pipe is not considered and all other consumers are installed in parallel, which does not influence the maximum pressure loss. Integrated night economy feature When the automatic night economy feature is activated, the circulation pump switches between normal mode and economy mode (characteristic curve MIN). The flow temperature is detected by a temperature sensor, the pump reacts accordingly. For this, it is necessary for the circulation pump to be installed in flow. Minimum inflow pressure Please determine the minimum inflow pressure for corresponding temperature from the following table. Media temperature < C > C Minimum inflow pressure. bar. bar Sound pressure level The sound pressure level is < db (A) Choice of control characteristic You can set different control modes via the potentiometer on the axial terminal box. Proportional pressure ( ), fixed speed ( ) and constant pressure ( ) can be adjusted continuously variable. The display indicates power consumption in [W] watts. Once the potentiometer is turned, the display first indicates mode of operation (PP, SC, CP), then value of set head in [m] meters. At the factory setting the potentiometer is in mode PP. Main areas of use eating, air-conditioning and industry systems as dual pipe system underfloor heating boiler/primary circuit storage charging circuit solar systems and heating pumps Materials Component Material Material no. Pump housing Grey-cast iron. Impeller Polyamide (PA - GF ) Shaft Bearing Bearing plate Stainless steel. Can Stainless steel.

45 igh efficiency pumps with LED display, electronically controlled and protected against condensation EP Optimo Geo series, G product group Type Connection pipe Threaded connection Installation length (mm) Voltage (V) P (W) In (A) Weight (kg) Product no. EEI EP Optimo Geo -. G ½ EP Optimo Geo -. G ½ EP Optimo Geo -. G ¼ EP Optimo Geo -. G ¼ EP Optimo Geo -. G ½ EP Optimo Geo -. G ½ EP Optimo Geo -. G ¾ ¼ EP Optimo Geo -. G ¾ ¼ EP Optimo Geo -. G ½ EP Optimo Geo -. G ½ Constant pressure EP Optimo Geo...-.-G Q (m / h) EP Optimo Geo...-.-G Q (m / h) Proportional pressure EP Optimo Geo...-.-G Q (m / h) EP Optimo Geo...-.-G Q (m / h) Fixed rpm EP Optimo Geo...-.-G Q (m / h) EP Optimo Geo...-.-G Q (m / h) Dimensions Type L L L L EP Optimo Geo / Dimension illustration G L L L L

46 igh efficiency pumps with LCD display, electronically controlled and protected against condensation EP Optimo L Geo series, G product group Insulation shell included in delivery. + Rate of flow: up to m /h Pressure head: m/ m Control range: - W/- W Media temperature: - C to + C Installation length: mm (thread)/ mm (flange) Threaded connection: ½ and (thread)/dn and DN (flange) Protection class: IP Insulation class: F Nominal pressure: PN EEI:. EP Optimo L XX-. GXXX. EP Optimo L XX-. GXXX Control: Internal: External: pc + pv + fixed rpm digital: PWM (characteristic lines for heating and solar per VDMA device paper ) frequency f nominal: - z voltage U nominal: - V power I: ma analogue: - V with cable break detection power I: ma impedance: kohm Omnibus fault message: Selector switch, potential-free, power max. A/ VAC Power supply for external unit: Voltage DC V, power max. ma Product features LCD display manual start-up feature smooth running very low energy consumption air-vent screw collective fault signal convenient operation axially integrated terminal box automatic adjustment to pressure conditions cataphoretic coated pump housing Use The electronically controlled EP Optimo L Geo high efficiency wet rotor circulators with LCD display and permanent magnet technology are designed for use in heating systems with variable or constant rate of flow. The cataphoretic coated pump housing is stainless. Main areas of use eating, air-conditioning and industry systems as dual pipe system single pipe system underfloor heating boiler/primary circuit storage charging circuit solar systems and heating pumps Materials Component Material Material No. Pump body Grey-cast iron. Impeller Polyamide (PA - GF ) Shaft Bearing Bearing plate Stainless steel. Can Stainless steel. Flow media heating water as per VDI pure, thin, non-aggressive and non-explosive, mineral oil-free media without solid or long-fibre components media with a max. viscosity of mm²/s operating data must be checked above % glycol Temperature range Ambient temperature: C to + C Temperature class: TF Media temperature: - C to + C Ambient temperature To avoid condensation forming in the terminal box and stator, the media temperture must always be the same or higher than the ambient temperature. Ambient temp. Media temp. min. Media temp. max. Motor protection External motor protection is not required. Minimum inflow pressure Please determine the minimum inflow pressure for corresponding temperature from the following table. Media temperature < C > C Minimum inflow pressure. bar. bar Controls Function You can make adjustments with the integrated control keys at the front. The LCD display shows the total electrical input power as a numeric value in [W] watts. Different icons at the top of the display show the function, setting and the modes of operation. Sound pressure level The sound pressure level is < db (A)

47 igh efficiency pumps with LCD display, electronically controlled and protected against condensation EP Optimo L Geo series, G product group Type Connection pipe Threaded connection Flange Installation length (mm) Voltage (V) P (W) In (A) Weight (kg) Product no. EEI EP Optimo L Geo -. G ½ EP Optimo L Geo -. G ½ EP Optimo L Geo -. G ¼ EP Optimo L Geo -. G ¼ EP Optimo L Geo -. G - - DN EP Optimo L Geo -. G - - DN EP Optimo L Geo -. G - - DN EP Optimo L Geo -. G - - DN Proportional pressure Constant pressure Fixed rpm EP Optimo L Geo...-. G EP Optimo L Geo...-. G EP Optimo L Geo...-. G step step step LOW LOW Q (m / h) Q (m / h) Q (m / h) Proportional pressure Constant pressure Fixed rpm EP Optimo L Geo...-. G EP Optimo L Geo...-. G step EP Optimo L Geo...-. G step step LOW LOW Q (m / h) Q (m / h) Q (m / h) Dimensions Type L L L L EP Optimo L (thread) EP Optimo L (flange). Dimension illustration L L L L A

48 Cold water circulation pumps (geothermy), pressure head - m KGPA series, G product group Flow media pure, thin, non-aggressive and non-explosive, mineral oil-free media without solid or long-fibre components media with a max. viscosity of mm²/s Temperature range Ambient temperature: C to + C Temperature class: TF Media temperature: - C to + C Motor protection External motor protection is not required. Speed switching The respective speed is set via a rotary switch integrated in the axial terminal box. Rate of flow: up to. m /h Pressure head: up to m Media temperature: - C to + C Installation length: mm Threaded connection: ½ and Protection class: IP Insulation class: Nominal pressure: PN Control: -step switch with manual speed selection Product features manual start-up feature space-saving axially integrated terminal box cataphoretic coated pump housing Minimum inflow pressure Please determine the minimum inflow pressure for corresponding temperature from the following table. Media temperature < C C C Minimum inflow pressure. bar. bar. bar Sound pressure level The sound pressure level is < db (A) Use The KGPA series circulation pumps are wet rotor circulators designed for use in cold water systems with a flow rate of > m /h. They feature an housing resistant to corrosion with KTL coating and a sealed motor winding. On request, pumps from the KGPA series are also available with a bronze housing (KGPB). Materials Component Material Material no. Pump housing Grey-cast iron. Impeller Polypropylene (PP - GF ) Shaft Bearing Bearing plate Brass. Can Stainless steel.

49 Cold water circulation pumps (geothermy), pressure head - m KGPA series, G product group Type Connection pipe Threaded connection Installation length (mm) Voltage (V) P (W) In (A) Weight (kg) Product no. *KGPA -. U ½ *KGPA -. U ½ *KGPA -. U ½ *KGPA -. U ½ *KGPA -. U ¼ *KGPA -. U ¼ *KGPA -. U ¼ *KGPA -. U ¼ * Also available with DN KGPA...-. U Q (m /h) KGPA...-. U Q (m /h) KGPA...-. U Q (m /h) KGPA...-. U Q (m /h) Dimensions Type L L L L KGPA. Dimension illustration G L L L L

50 Condensate pump for gas condensing boilers up to kw Lift series, K product group Use The Lift condensate pump is a fully automatic unit for the extraction of condensate, produced in gas/oil condensing boilers, air-conditioning systems, refrigerated counters and dehumidifiers incl. collection tank. It can be used anywhere where a condensate disposal through gravity is not possible or where there is no direct drain. The Lift condensate pump is designed for gas condensing boilers up to kw. The housing is made from ABS plastic and is therefore resistant to acidic condensate (p ). For very acidic condensate (p < ), for the use of low-sulfur heating oil and for installations/systems with over kw, it is compulsory according to ATV- DVWK-A in Germany to install a neutralization system (see condensate pump Lift NT resp. additional neutralization tank NT). Complementary municipal or other national regulations must be observed where necessary. For the use in oil condensing boilers we recommend the additional use of an extension kit with activated carbon (see accessories for condensate pumps). Electrical connection: V, / z Input power: W Alarm contact: max. V, A (resistive load), NO normally open/nc normally closed Protection class: IP Medium: condensate p, temperature C max Rate of flow: max. l/h Pressure head: max. m Noise level: max. db [A] Dimensions: x x mm (L x W x ) Condensate supply: Ø mm Condensate suction head: mm Tank: ABS plastic, max.. l/. Gal Condensation drain: nozzles for hose connection Ø x mm Discharge hose: included in the scope of delivery Weight:. kg Product features fully automatic condensate pump delivered completely ready for connection Main areas of use gas condensing boilers oil condensing boilers air-conditioning systems refrigerators, refrigerated cabinets, refrigerated counters* dehumidifiers, evaporators *) not suitable for splash water Flow media condensates with a p and a C max temperature condensates with a p over have to be neutralized condensates with oil residues from oil condensing boilers must be cleaned with activated carbon (extension kit) if necessary Temperature range Media temperature: + C to + C Ambient temperature: + C to + C Switching points Alarm max. mm Start +/- mm Stop +/- mm extremely quiet and vibration free very compact and space-saving construction fully encapsulated pump unit (IP ) resistant to water jets from any direction pump unit also suitable for use in external tank (tank height min. mm, max. mm) integrated check valve for discharge hose condensation discharge hose ( m, Ø x mm) included in delivery pre-mounted power cable (. m) incl. shockproof plug overflow protection through separate float potential-free alarm connection (NO normally open/nc normally closed) pre-mounted alarm cable (. m) incl. wall mounting Delivery program Lift Q (l/h) Type Max pressure head Max rate of flow For condensing boilers up to Remarks Product no. Lift m l/h kw incl. pressure hose ( m, Ø x mm) -

51 Condensate pump for gas condensing boilers up to kw Lift Basic series, K product group Use The Lift Basic condensate pump is a fully automatic unit for the extraction of condensate, produced in gas/oil condensing boilers, air-conditioning systems, refrigerated counters and dehumidifiers incl. collection tank. It can be used anywhere where a condensate disposal through gravity is not possible or where there is no direct drain. The Lift Basic condensate pump is designed for gas condensing boilers up to kw. The housing is made from ABS plastic and is therefore resistant to acidic condensate (p ). For very acidic condensate (p < ), for the use of low-sulfur heating oil and for installations/systems with over kw, it is compulsory according to ATV- DVWK-A in Germany to install a neutralization system (see condensate pump Lift NT resp. additional neutralization tank NT). Complementary municipal or other national regulations must be observed where necessary. For the use in oil condensing boilers we recommend the additional use of an extension kit with activated carbon (see accessories for condensate pumps). Electrical connection: V, / z Input power: W Alarm contact: max. V, A (resistive load), NO normally open/nc normally closed Protection class: IP Medium: condensate p, temperature C max Rate of flow: max. l/h Pressure head: max. m Noise level: max. db [A] Dimensions: x x m (L x W x ) Condensate supply: Ø mm Condensate suction head: mm Tank: ABS plastic, max.. l/. Gal Condensation drain: nozzles for hose connection Ø x mm Discharge hose: included in the scope of delivery Weight:. kg Main areas of use gas condensing boilers oil condensing boilers air-conditioning systems refrigerators, refrigerated cabinets, refrigerated counters* dehumidifiers, evaporators *) not suitable for splash water Flow media condensates with a p and a C max temperature condensates with a p over have to be neutralized condensates with oil residues from oil condensing boilers must be cleaned with activated carbon (extension kit) if necessary Temperature range Media temperature: + C to + C Ambient temperature: + C to + C Product features fully automatic condensate pump delivered completely ready for connection extremely quiet space-saving construction housing made from ABS plastics is resistant to condensate integrated check valve for discharge hose condensation discharge hose ( m, Ø x mm) included in delivery pre-mounted power cable (. m) incl. shockproof plug overflow protection through separate float potential-free alarm connection (NO normally open/nc normally closed) pre-mounted alarm cable (. m) incl. wall mounting Delivery program Lift Basic Q (l/h) Type Max pressure head Max rate of flow For condensing boilers up to Remarks Product no. Lift Basic m l/h kw incl. pressure hose ( m, Ø x mm) -

52 Condensate pump for oil condensing boilers with neutralization tank Lift NT series, K product group Electrical connection: V, / z Input power: W Alarm contact: max. V, A (resistive load), NO normally open/nc normally closed Protection class: IP Medium: condensate p, temperature C max Rate of flow: max. l/h Pressure head: max. m Noise level: max. db [A] Dimensions: x x m (L x W x ) Condensate supply: Ø mm Condensate suction head: mm Neutralization tank: ABS plastic,. l/. Gal, incl. neutralization granulate ( kg) Condensation drain: nozzles for hose connection Ø x mm Weight:. kg Schematic sketch Lift NT ose nipple suitable for PVC hose, nominal width mm ose length cm Condensate intake Filter Granular Product features fully automatic condensate pump delivered completely ready for connection, incl. neutralization tank noise-reducing electronic controls with follow-up time to reduce switching frequency space-saving construction integrated collection/neutralization tank, incl. first fill with neutralization granulate ( kg) sufficient for about months for systems up to kw upstream suction filter as well as check valve for discharge hose connection for discharge hose (Ø x. mm) Flow direction Main areas of use gas condensing boilers oil condensing boilers Sieve insert with filter Float switch Alarm float switch Flow media condensates produced in gas and oil condensing boilers with a C max temperature condensates with oil residues from oil condensing boilers must be cleaned with activated carbon (extension kit) if necessary Temperature range Media temperature: + C to + C Ambient temperature: + C to + C pre-mounted power cable (. m) incl. shockproof plug overflow protection through separate float potential-free alarm connection (NO normally open/nc normally closed) Use The Lift NT condensate pump is a fully automatic unit for the extraction of condensate, produced in gas/oil condensing boilers, air-conditioning systems, refrigerated counters and dehumidifiers incl. collection/neutralization tank. It can be used anywhere where a condensate disposal through gravity is not possible or where there is no direct drain. The Lift NT condensate pump is designed for gas and oil condensing boilers up to kw. It is extensible for systems up to kw with additional accessories NB and NT. The housing is made from ABS plastic and is therefore resistant to acidic condensate (p ). For the use in oil condensing boilers we recommend the additional use of an extension kit with activated carbon (see accessories for condensate pumps). Lift NT,,,,,,, Q (l/h)

53 Condensate pump for oil condensing boilers with neutralization tank Lift NT series, K product group Delivery program Type Max pressure head Max rate of flow For condensing boilers up to Remarks Product no. Lift NT m l/h kw incl. neutralization tank incl. first fill with neutralization granulate - Connection alarm cable Electronic circuitry Lift NT N L PE L N PE NO C NC Changeover contact Relay A/ V ohmic load Terminal NO-C: normally open contact NC-C: normally closed contact L N PE Consumer Connection example for potential-free contact Cable length m Lift NT

54 Accessories/Spare parts for circulation pumps Z product group Screw connections without picture Type Product no. Description Grey cast iron connection G -. set c.i. connection Rp ½ x G Grey cast iron connection G ¼ -. set c.i. connection Grey cast iron connection G ½ -. set c.i. connection Rp x G ½ Grey cast iron connection G -. set c.i. connection Rp ¼ x G Brass connection G -. set brass connection Rp ½ x G Brass connection G ¼ -. set brass connection Rp ¾ x G ¼ Brass connection G ½ -. set brass connection Rp x G ½ Flange adaptors for pipe installation (flange) Type Product no. Description FA - flange adaptor grey-cast iron (PN) incl. screws + seal, DN, mm FA - flange adaptor grey-cast iron (PN) incl. screws + seal, DN, mm FA - flange adaptor grey-cast iron (PN) incl. screws + seal, DN, mm FA - flange adaptor grey-cast iron (PN) incl. screws + seal, DN, mm FA - flange adaptor grey-cast iron (PN) incl. screws + seal, DN, mm FA - flange adaptor grey-cast iron (PN) incl. screws + seal, DN, mm FA - flange adaptor grey-cast iron (PN) incl. screws + seal, DN, mm FA - flange adaptor grey-cast iron (PN) incl. screws + seal, DN, mm FA - flange adaptor grey-cast iron (PN) incl. screws + seal, DN, mm Insulation shell/insulation shell for cold water applications Type Product no. Description WDS A - Insulation shell for EP Optimo (Basic) with installation length mm WDS B - Insulation shell for EP Optimo L with installation length mm WDS C / - Insulation shell for EP Optimo L+ with connection G ½ and WDS C -. - Insulation shell for EP Optimo L+ -. WDS C -. - Insulation shell for EP Optimo L+ -. WDS C -./. - Insulation shell for EP Optimo L+ -./. WDS C -./-./. - Insulation shell for EP Optimo L+ -. and -./. WDS C -./. - Insulation shell for EP Optimo L+ -./. WDS C -. - Insulation shell for EP Optimo L+ -. WDS C -. - Insulation shell for EP Optimo L+ -. KDS C -// -// - Insulation shell for cold water applications for EP Optimo L+ -././. and -././. KDS C -. - Insulation shell for cold water applications for EP Optimo L+ -. Plug Type Product no. Description Plug complete -- Plug for series EP complete incl. Socket on motor side without picture Socket only - Socket on motor side for plug for series EP Further accessories and spare parts on request.

55 Accessories/Spare parts for condensate pumps Z product group Maintenance kit for Lift NT Type Product no. Description Maintenance kit for Lift NT - Maintenance kit for Lift NT for the yearly maintenance consisting of neutralization granulate ( kg), replacement filter sieve with fleece, replacement filter element for suction filters. Extension kit oil condensing boilers Type Product no. Description Extension kit oil condensing boilers - Extension kit for Lift NT for oil condensing boilers consisting of activated carbon filter and sieve. NT Type Product no. Description NT - Additional collection/neutralization tank with granulate ( x kg) for neutralization capacity kw, filter sieves (x) and connection/ nozzle for the connection to the Lift NT. Condensate supply opening Ø mm/condensate supply height mm. NG Type Product no. Description NG - Refill pack neutralization granulate ( kg) Alarm plus Type Product no. Description Alarm plus - Audio and visual fault indicator for the alarm output of the condensate pump ( V, / z) for the connection to the condensate pump with alarm relay output, x x mm (L x W x ), input power. W, IP, ambient temperature + C to + C. Further accessories and spare parts on request.

56 Your representative: Product no. --EN Version. (/) alm Pumpen + Motoren Gmb Silcherstrasse - Baltmannsweiler, Germany Postfach Baltmannsweiler, Germany Tel: + - Fax: + info@halm.info Web: +

Lenntech. Calio S. Type Series Booklet. High-efficiency Circulator Pump. Tel Fax.

Lenntech. Calio S. Type Series Booklet. High-efficiency Circulator Pump. Tel Fax. Lenntech info@lenntech.com Tel. +--6-9 www.lenntech.com Fax. +--66-89 High-efficiency Circulator Pump Type Series Booklet Legal information/copyright Type Series Booklet All rights reserved. The contents

More information

3 Specification Magneta Smedegaard

3 Specification Magneta Smedegaard 3 Specification Magneta Smedegaard 3.1 Variable Speed Circulator Pumps Main applications Heating, ventilation, air-conditioning, refrigerating and circulation systems - One-pipe and two-pipe systems -

More information

General catalogue incl. replacement lists

General catalogue incl. replacement lists Circulation pumps effiziente Pumpentechnologie General catalogue 2009 incl. replacement lists Data might be subject to alteration, errors excepted! Content I. Product programme Product overview... 1 Type

More information

4 Specification Magneta Smedegaard twin pumps

4 Specification Magneta Smedegaard twin pumps 4 Specification Magneta Smedegaard twin pumps 4.1 Variable Speed Circulator Pumps Designation: Example Magneta Smedegaard 30-60D Key to the designation Main applications Heating, ventilation, air-conditioning,

More information

Lenntech. Calio-Therm S. Type Series Booklet. High-efficiency Drinking Water Pump

Lenntech. Calio-Therm S. Type Series Booklet. High-efficiency Drinking Water Pump Lenntech info@lenntech.com Tel. +--6-9 www.lenntech.com Fax. +--66-89 High-efficiency Drinking Water Pump Calio-Therm S Type Series Booklet Legal information/copyright Type Series Booklet Calio-Therm S

More information

High-efficiency Drinking Water Pump. Rio-Eco Therm N. Type Series Booklet

High-efficiency Drinking Water Pump. Rio-Eco Therm N. Type Series Booklet High-efficiency Drinking Water Pump Rio-Eco Therm N Type Series Booklet Legal information/copyright Type Series Booklet Rio-Eco Therm N All rights reserved. The contents provided herein must neither be

More information

RE, RED. Electronically Controlled Inverter Driven Circulation Pump. Twin Execution ENERGY EFFICIENCY OF CIRCULATING PUMPS

RE, RED. Electronically Controlled Inverter Driven Circulation Pump. Twin Execution ENERGY EFFICIENCY OF CIRCULATING PUMPS , RED Electronically Controlled Inverter Driven Circulation Pump Twin Execution ENERGY EFFICIENCY OF CIRCULATING PUMPS Directive of the European Parliament COMMISSION REGULATION (EC) No. 641/2009 and 622/2012

More information

Series description: Wilo-Stratos ECO-STG

Series description: Wilo-Stratos ECO-STG Series description: ()- Design Glandless circulation pump with threaded connection, EC motor and automatic power adjustment Application Primary circuits of solar and geothermal systems Type key Example:

More information

Heating, air-conditioning, cooling

Heating, air-conditioning, cooling Series overview Series: Wilo-Stratos-D 3 Q[m³h] Wilo-Stratos-D Hz x3-3x3-3 Q[USg pm] >Design In line, flanged wet rotor double circulator with EC motor and automatic capacity adjustment >Application Hot-water

More information

Japanese Technology since Ego Circulators. Databook

Japanese Technology since Ego Circulators. Databook Japanese Technology since 1912 Ego Circulators Databook Japanese Technology since 1912 www.ebaraeurope.com INDEX Ego Range GENERAL INTRODUCTION THREADED CIRCULATORS THREADED/FLANGED CIRCULATORS FLANGED

More information

Circulator Pumps with Continuously Variable Differential Pressure Control and I.R. Interface for Remote Control

Circulator Pumps with Continuously Variable Differential Pressure Control and I.R. Interface for Remote Control Type series booklet 1115.52/2-10 Riotec r /Riotec r Z Circulator Pumps with Continuously Variable Differential Pressure Control and I.R. Interface for Remote Control Riotec Riotec Z Energy efficiency class

More information

Data sheet: Wilo-Stratos PICO 25/1-6

Data sheet: Wilo-Stratos PICO 25/1-6 Data sheet: Wilo-Stratos PICO 25/1-6 Pump curves Δp-c (constant) 5 4 v 1 2 3 4 5 6,5 1, p-c Rp ½ 1,5 2, Rp 1 m/s,4,8 1,2 1,6 Rp 1¼ H/m Wilo-Stratos PICO 15/1-6, 25/1-6, 3/1-6 6 1~23 V - Rp ½, Rp 1, Rp

More information

Data sheet: Wilo-Stratos PICO 25/

Data sheet: Wilo-Stratos PICO 25/ Data sheet: Wilo-Stratos PICO 25/1-4-13 Pump curves Δp-c (constant) 1 2 p-c v 3 4 5 Rp ½,4,8 1,2 1,6 Rp 1m/s,2,4,6,8 1, 1,2 Rp 1¼ H/m 4, Wilo-Stratos PICO 15/1-4, 25/1-4, 3/1-4 1~23 V - Rp ½, Rp 1, Rp

More information

Data sheet: Wilo-Yonos MAXO 40/0,5-16

Data sheet: Wilo-Yonos MAXO 40/0,5-16 Data sheet: /,5- Pump curves v 5 5 5 6 P /W n= const 5 5 /,5- ~ V - DN /,5- ~ V - DN 6 m/s Approved fluids (other fluids on request) Heating water (in accordance with VDI 5) Water-glycol mixtures (max.

More information

GRUNDFOS DATA BOOKLET. Grundfos UPBasic. Circulator pumps 50 Hz

GRUNDFOS DATA BOOKLET. Grundfos UPBasic. Circulator pumps 50 Hz GRUNDFOS DATA BOOKLET Grundfos UPBasic Circulator pumps 50 Hz Contents General data Performance ranges Page Product range, 1 x 0 V, 50 Hz Page 4 Type key Page 4 Construction Page 4 Material specification

More information

TECHNICAL DATA. ErP Ready NewMotorTechnolgy. Electronically controlled high-efficiency pumps for heating, air conditioning, cooling and sanitary water

TECHNICAL DATA. ErP Ready NewMotorTechnolgy. Electronically controlled high-efficiency pumps for heating, air conditioning, cooling and sanitary water w w w. im p - p u m p s. co m Electronically controlled high-efficiency pumps for heating, air conditioning, cooling and sanitary water ErP Ready NewMotorTechnolgy IMPPUMPS Technical Data 2014 TECHNICAL

More information

Data sheet: Wilo-TOP-S 40/4 (1~230 V, PN 6/10)

Data sheet: Wilo-TOP-S 40/4 (1~230 V, PN 6/10) Data sheet: Wilo-TOP-S 4/4 (1~23 V, PN 6/1) Pump curves Single-phase current H/m 4 3 v,5 1, 1,5 2, 2,5 3, Wilo-TOP-S 4/4 1~23 V - DN 4 m/s Approved fluids (other fluids on request) Heating water (in accordance

More information

Data sheet: Wilo-TOP-S 40/10 (1~230 V, PN 6/10)

Data sheet: Wilo-TOP-S 40/10 (1~230 V, PN 6/10) Data sheet: Wilo-TOP-S 4/1 (1~23 V, PN 6/1) Pump curves Single-phase current H/m 1 8 v 1 2 3 4 Wilo-TOP-S 4/1 1~23 V - DN 4 5m/s p/kpa 1 8 Approved fluids (other fluids on request) Heating water (in accordance

More information

Data sheet: Wilo-Stratos-D 32/1-8

Data sheet: Wilo-Stratos-D 32/1-8 Data sheet: Wilo-Stratos-D 32/1-8 Pump curves Δp-c (constant) H/m 7 v 1 2 3 4 5 6 5 p-c Wilo-Stratos-D 32/1-8 1~23 V - DN 32 + m/s p/kpa 7 6 5 Approved fluids (other fluids on request) Heating water (in

More information

Data sheet: Wilo-Stratos-D 50/1-12

Data sheet: Wilo-Stratos-D 50/1-12 Data sheet: Wilo-Stratos-D 5/1-12 Pump curves Δp-c (constant) H/m 12 1 8 6 4 v 1 2 3 4 5 6 p-c Wilo-Stratos-D 5/1-12 1~23 V - DN 5 max. + m/s p/kpa 12 1 8 6 4 Approved fluids (other fluids on request)

More information

Grundfos Home Booster

Grundfos Home Booster GRUNDFOS DATA BOOKLET Grundfos Home Booster UPA 15-9, UPA 15-12, UPA 15-16, UPA 12 5/6 Hz Grundfos Home Booster Table of contents 1. Product description 3 Applications..................................................................................

More information

real quality made in italy circulation pumps

real quality made in italy circulation pumps GB real quality made in italy circulation pumps real quality made in italy E N E R G Y S A V I N G P U M P S PUMPING TECHNOLOGY Due to the diversity of nominal diameters, body lengths and speeds our extremely

More information

Data sheet: Wilo-Yonos PICO 25/

Data sheet: Wilo-Yonos PICO 25/ Data sheet: Wilo-Yonos PICO 25/1-5-13 Pump curves H/m 5 4 3 2 1,4,8 1,2 1,6,5 1, 1,5 2, 2,5 3,,2,4,6,8 2 4 6 8 1 P 1/W 3 2 1 4m p-c Wilo-Yonos PICO 25/1-5 1~23 V - Rp 1,5 1, 1,5 2, 2,5 3, Pump curves H/m

More information

Data sheet: Wilo-Stratos-Z 25/1-8

Data sheet: Wilo-Stratos-Z 25/1-8 Data sheet: Wilo-Stratos-Z 25/1-8 Pump curves 7 337 1 /min - 9 V 6 34 1 /min - 8 V 5 271 4 1 /min - 7 V 239 1 /min - 6 V 3 26 1 /min - 5 V 2 173 1 /min - 4 V 14 1 1 /min - 3 V 2 4 6 8,5 1, 1,5 2, 2,5 Q/l/s

More information

EVOPLUS / EVOPLUS SAN

EVOPLUS / EVOPLUS SAN in line with European Directive ErP 2009/125/EC (formerly EuP) of 2015 EVOPLUS / EVOPLUS SAN TECHNICAL DATA Operating range: from 3 a 75.6 m³/h with head of up to 18 metres. Pumped liquid temperature range:

More information

EVOTRON SAN WET ROTOR ELECTRONIC CIRCULATORS TECHNICAL DATA

EVOTRON SAN WET ROTOR ELECTRONIC CIRCULATORS TECHNICAL DATA EVOTRON SAN TECNICAL DATA Operating range: from, -, m3/h with head of up to metres. Pumped liquid temperature range: from - C to + C. Working pressure: bar ( kpa). Protection class: IP X. Insulation class:

More information

Data sheet: Wilo-TOP-Z 50/7 (3~400 V, PN 6/10, RG)

Data sheet: Wilo-TOP-Z 50/7 (3~400 V, PN 6/10, RG) Data sheet: Wilo-TOP-Z 5/7 (3~4 V, PN 6/1, RG) Pump curves Three-phase current H/m 7 6 5 4 3 2 1 P1/W 6 4 2 v,5 1 1,5 2 2,5 3 3,5 Wilo-TOP-Z 5/7 3~4 V - DN 5 1 2 3 4 5 6 7 Dimension drawing 66 66 DN 5

More information

NBE40-125/139 AS-F2-A-BAQE

NBE40-125/139 AS-F2-A-BAQE GRUNDFOS DATA BOOKLET NBE-125/139 AS-F2-A-BAQE Grundfos pump 999983 Thank you for your interest in our products. Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/nbe/999983/nbe--125-139-as-f2-a-e-baqe.html

More information

High efficiency pumps

High efficiency pumps ONLY ORIGINAL WIT TE ROMB PUMP TECNOLOGY igh efficiency pumps www.wita-taake.de Pump Technology igh efficiency pumps Pump Technology Since more than years the company WITA is developing and producing highquality

More information

Heating, air-conditioning, cooling

Heating, air-conditioning, cooling Series overview Wilo-Stratos-D Design Self regulating dual volute Inline, ECM (Electronically Communicated) type Application Hot and chilled water hydronics, air conditioning, solar and geothermal systems

More information

In-Line Dry Rotor Circulating Pumps. EIL R Series EIL- FK Series

In-Line Dry Rotor Circulating Pumps. EIL R Series EIL- FK Series EIL R Series EIL- FK Series ETNA Experience Environment Friendly Engineering Exact Answer to Your Need With our R&D, production and installation experience of more than 3 years in the pump technologies

More information

Data sheet: Wilo-VeroTwin-DPL 40/ /4

Data sheet: Wilo-VeroTwin-DPL 40/ /4 Data sheet: Wilo-VeroTwin-DPL 4/13-.2/4 Pump curves 4-pole - individual operation H[m] 8 7 6 4 3 2 1 P 2 [kw],4,2 η p[%] 6 4 2 1 2 3 4 6 7 Qmin Pump curves Wilo-VeroTwin-DPL 4/16 - Wilo-VeroTwin-DPL 4/13

More information

NB /438 A-F1-A-GQQE

NB /438 A-F1-A-GQQE GRUNDFOS DATA BOOKLET NB15-4/438 A-F1-A-GQQE Grundfos pump 983626 Thank you for your interest in our products. Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/nb/983626/nb-15-4-438-a-f1-a-e-gqqe.html

More information

NBE50-250/205 A-F2-A-BAQE

NBE50-250/205 A-F2-A-BAQE GRUNDFOS DATA BOOKLET NBE5-25/25 A-F2-A-BAQE Grundfos pump 9518635 Thank you for your interest in our products. Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/nbe/9518635/nbe-5-25-25-a-f2-a-e-baqe.html

More information

Volute Casing Centrifugal Pumps PN 16 for heat-transfer liquids Heat-transfer oil up to 350 C Hot water up to183 C

Volute Casing Centrifugal Pumps PN 16 for heat-transfer liquids Heat-transfer oil up to 350 C Hot water up to183 C Volute Casing Centrifugal Pumps PN 16 for heat-transfer liquids Heat-transfer oil up to 350 C Hot water up to183 C Series CMIT in inline design Series CMAT with axial inlet ATEX 0 a Series CMAT Series

More information

SIHI multi Type MSC. Modular multistage pumps. Description. Construction. Applications. Optional special designs. Materials.

SIHI multi Type MSC. Modular multistage pumps. Description. Construction. Applications. Optional special designs. Materials. Modular multistage pumps SIHI multi Type MSC Description The SIHI multi MSC range of horizontal, ring-section multistage pumps have been designed for long-term reliability when pumping high pressure liquids.

More information

SP A, SP. Submersible pumps Submersible motors Accessories. 50 Hz

SP A, SP. Submersible pumps Submersible motors Accessories. 50 Hz SP A, SP Submersible motors Accessories For raw water supply, irrigation systems, groundwater lowering, pressure boosting and various industrial applications. 5 Hz TM 7318 2298 Contents General data Performance

More information

Data sheet: Wilo-VeroTwin-DPL 65/ /2

Data sheet: Wilo-VeroTwin-DPL 65/ /2 Data sheet: Wilo-VeroTwin-DPL 65/175-5.5/2 Pump curves 2-pole - individual operation H[m] 35 3 25 2 Qmin DPL 65/175-5,5/2 Wilo-VeroTwin-DPL 65/175 - Wilo-VeroTwin-DPL 65/165 DPL 65/175-7,5/2 DPL 65/165-5,5/2

More information

CENTRIFUGAL IMMERSION PUMPS

CENTRIFUGAL IMMERSION PUMPS CENTRIFUGAL IMMERSION PUMPS FLUX CENTRIFUGAL IMMERSION PUMPS QUALITY THAT SETS STANDARDS Manufactured at our main plant, these ranges of immersion pumps are the result of extensive product and process

More information

Centrifugal Immersion Pumps

Centrifugal Immersion Pumps Centrifugal Immersion Pumps FLUX Centrifugal Immersion Pumps Quality that sets standards. Manufactured at our main plant, these ranges of immersion pumps are the result of extensive product and process

More information

ABS submersible sewage pump AFP

ABS submersible sewage pump AFP BS submersible sewage pump FP - Robust, reliable submersible pumps from. to kw for pumping wastewater and sewage from buildings and sites in private, commercial, industrial and municipal areas in accordance

More information

Series description: Wilo-TOP-STGD

Series description: Wilo-TOP-STGD ATAC Solutions 1622 8824 / Series description: Wilo-TOP-STGD Wilo-TOP-STGD 15 4/ 1 5 Design Glandless double circulation pump with flange connection. Application Primary circuits of solar and geothermal

More information

Paddle-wheel flow controller for On/Off control

Paddle-wheel flow controller for On/Off control Paddle-wheel flow controller for On/Off control Type 803 can be combined with... Indication, monitoring, transmitting and On/Off control in one device Programmable s (transistor or relay) Automatic-calibration:

More information

- CONSTRUCTIONS 300 SECTIONAL VIEW DRAWING 300 SECTIONAL VIEW TABLE 301 QUANTITY FOR MODEL 302 MECHANICAL SEAL 303 BEARINGS 304 FITTINGS 305

- CONSTRUCTIONS 300 SECTIONAL VIEW DRAWING 300 SECTIONAL VIEW TABLE 301 QUANTITY FOR MODEL 302 MECHANICAL SEAL 303 BEARINGS 304 FITTINGS 305 CONTENTS Page - SPECIFICATIONS 200 SELECTION CHART 201 SELECTION CHART TABLE 202 TYPE KEY AND CURVE SPECIFICATIONS 203 PERFORMANCE CURVE 3 ( 3-4-5-6 IMPELLERS ) 205 PERFORMANCE CURVE 3 ( 7-8-9 IMPELLERS

More information

Company name: Created by: Phone:

Company name: Created by: Phone: Qty. 1 MAGNA3 D -6 Date: 6/3/217 Product No.: 9792445 With its unrivalled efficiency, all-encompassing range and built-in communication capabilities, the MAGNA3 is ideal for engineers and specifiers looking

More information

- CONSTRUCTIONS 300 SECTIONAL VIEW 300 CONSTRUCTIONS 301 CONSTRUCTIONS 302 MECHANICAL SEAL 303 COUNTERFLANGE 304

- CONSTRUCTIONS 300 SECTIONAL VIEW 300 CONSTRUCTIONS 301 CONSTRUCTIONS 302 MECHANICAL SEAL 303 COUNTERFLANGE 304 CONTENTS Page - SPECIFICATIONS 200 PUMP SPECIFICATION 200 TYPE KEY 201 SELECTION CHART 202 SELECTION CHART 203 PERFORMANCE CURVE 3 ( 3-4-5-6 impellers ) 204 PERFORMANCE CURVE 3 ( 7-8-9 impellers ) 205

More information

Centrifugal performance characteristics with axial flow pattern: RADAX VAR

Centrifugal performance characteristics with axial flow pattern: RADAX VAR High pressure in-line mixed-flow fans RADAX VAR Centrifugal performance characteristics with axial flow pattern: RADAX VAR COMPACT PRESSURE-RESISTANT UNIVERSAL In their compact casing, the RADAX VAR impellers

More information

Series description: Wilo-Stratos

Series description: Wilo-Stratos Series description: Wilo-Stratos H/m 16 14 12 1 8 6 4 2 25(3,32,4,5)/1-1 25(3)/1-8 25(3)/1-6 25(3)/1-4 5/1-12 4/1-4 4/1-12 32/1-12 4(5)/1-8 3/1-12 4/1-16 5/1-9 65/1-9 65/1-12 Wilo-Stratos 65/1-16 5/1-16

More information

Pump Stations for Heating Circuits

Pump Stations for Heating Circuits Pump Stations for Heating Circuits circulation pumps pump stations manifolds Regulus spol. s r.o., Czech Republic Do Koutů 897/, Praha Tel.: + 7 9, Fax: + 7 97 E-mail: sales@regulus.eu Web: www.regulus.eu

More information

our contribution for Sealless Magnetic Coupled Multistage Centrifugal Pumps Type HZM / HZMR / HZMB environmental protection

our contribution for Sealless Magnetic Coupled Multistage Centrifugal Pumps Type HZM / HZMR / HZMB environmental protection Sealless Magnetic Coupled Multistage Centrifugal Pumps Type HZM / HZMR / HZMB our contribution for environmental protection General DICKOW-pumps of series HZM are sealless multistage horizontal centrifugal

More information

Connection. k VS -Value m 3 /h

Connection. k VS -Value m 3 /h 56.108/1 BUF: 3--way valve with male thread, PN16 Features Control valve for continuous control of cold water, and hot water in closed networks. Water quality as per VDI 2035. In combination with valve

More information

Centrifugal pumps. made of Polypropylene and PVDF for transferring aggressive media like acids and alkalies

Centrifugal pumps.  made of Polypropylene and PVDF for transferring aggressive media like acids and alkalies Vertical and horizontal centrifugal pumps www.jesspumpen.com Centrifugal pumps made of Polypropylene and PVDF for transferring aggressive media like acids and alkalies Vertical centrifugal pumps of the

More information

Data sheet: Wilo-VeroTwin-DPL 50/ /4

Data sheet: Wilo-VeroTwin-DPL 50/ /4 Data sheet: Wilo-VeroTwin-DPL 5/6-.55/ Pump curves -pole - individual operation H[m] 7 6 5 P [kw],6,, η p[%] 6 Qmin Wilo-VeroTwin-DPL 5/6 - Wilo-VeroTwin-DPL 5/ DPL 5/-,7/ DPL 5/6-,55/ 6 Ø 7 Pump curves

More information

TD-MIXVENT Series IN-LINE MIXED FLOW DUCT FANS TD-MIXVENT. In-Line duct fans

TD-MIXVENT Series IN-LINE MIXED FLOW DUCT FANS TD-MIXVENT. In-Line duct fans IN-LINE MIXED FLOW DUCT FANS Series Range of low profile in-line mixed flow duct fans manufactured in tough reinforced plastic (from 160 to 800 models) or with metal casing steel finished in a tough epoxy-polyester

More information

High Pressure Centrifugal Pumps Product Overview

High Pressure Centrifugal Pumps Product Overview High Pressure Centrifugal Pumps Product Overview High Pressure Centrifugal Pumps Product Overview Wilo-Economy MHI Duty chart H[m] 6 5 4 Wilo-Economy-MHI 5 Hz Non self-priming pumps for: Water supply and

More information

Series DDC DC Electronically Commutated Spherical Motor Centrifugal Pumps

Series DDC DC Electronically Commutated Spherical Motor Centrifugal Pumps Series DDC DC Electronically Commutated Spherical Motor Centrifugal Pumps Applications Specifically designed for the following uses: Electronics Cooling Medical Water Circulation Chiller Systems Liquid

More information

Pumps Certified for North American Market

Pumps Certified for North American Market Pioneering for You Version 2015/09 Pumps Certified for North American Market Subject to change without prior notice WLO SE Introduction History In 1872, Louis Opländer founded Wilo as a copper a brass

More information

TPED /4-S-A-F-A-BAQE 3X400 50HZ

TPED /4-S-A-F-A-BAQE 3X400 50HZ GRUNDFOS DATA BOOKLET TPED -9/-S-A-F-A-BAQE 3X 5HZ Grundfos Pump 99137 Thank you for your interest in our products Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/tpeds/99137/tped--9--s-a-f-a-baqe.html

More information

TPE N-A-F-A-GQQE

TPE N-A-F-A-GQQE GRUNDFOS DATA BOOKLET TPE2 1-15-N-A-F-A-GQQE Grundfos Pump 98416973 Thank you for your interest in our products Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/tpe/98416973/tpe2-1-15-n-a-f-a-gqqe.html

More information

Transformer Oil Cooling Solutions

Transformer Oil Cooling Solutions pumps and fans Transformer Oil Cooling Solutions Series NTG/ TG/ TGCL Pumps TF/ TFBR/ NTF/ VTTF Fans quality certificate INDEX The company Portfolio Development PUMPS Nomenclature Inline axial pumps NTG

More information

Customised drive solutions

Customised drive solutions Customised drive solutions Electric motors & systems Drive components Services Introduction 03 Halm quality drive technology Over 50 years of experience in developing electric motors with asynchronous

More information

herborner.x -C Technical data brochure 50 Hz

herborner.x -C Technical data brochure 50 Hz herborner.x -C % COATING = % CORROSION! Technical data brochure z The coated pool water circulation pump with a close coupled design with heat exchanger motor: Efficient, flexible and long-lasting all

More information

MODEL INFORMATION CANNED MOTOR PUMP TYPE CAM HERMETIC

MODEL INFORMATION CANNED MOTOR PUMP TYPE CAM HERMETIC MODEL INFORMATION CANNED MOTOR PUMP TYPE CAM HERMETIC ... 3... 4 3000 rpm 50 Hz / 3600 rpm 60 Hz... 4... 5... 7 Modular pump / motor systems... 7 Materials...........................................................

More information

Submersible Borehole Pump. UPAchrom. 4", UPAchrom 100 CC + DN 100. Type Series Booklet

Submersible Borehole Pump. UPAchrom. 4, UPAchrom 100 CC + DN 100. Type Series Booklet Submersible Borehole Pump UPAchrom 4", UPAchrom 1 CC + DN 1 Type Series Booklet Legal information/copyright Type Series Booklet UPAchrom All rights reserved. The contents provided herein must neither be

More information

UNIT TAG: TYPE OF SERVICE: SUBMITTED BY: APPROVED BY: ORDER NO.: MAGNA F N. Pump Data

UNIT TAG: TYPE OF SERVICE: SUBMITTED BY: APPROVED BY: ORDER NO.: MAGNA F N. Pump Data Submittal Data PROJECT: REPRESENTATIVE: ENGINEER: CONTRACTOR: UNIT TAG: TYPE OF SERVICE: SUBMITTED BY: APPROVED BY: ORDER NO.: MAGNA3 4-8 F N QUANTITY: Full range of intelligent, high-efficiency circulators

More information

Data sheet: Wilo-TOP-Z 30/7 (3~400 V, PN 10, RG)

Data sheet: Wilo-TOP-Z 30/7 (3~400 V, PN 10, RG) Data sheet: Wilo-TOP-Z 3/7 (3~4 V, PN 1, RG) Pump curves Three-phase current H/m 5 4 v,5 1 1,5 2 2,5 Wilo-TOP-Z 3/7 3~4 V - Rp 1¼ m/s Approved fluids (other fluids on request) Drinking water and water

More information

Data sheet: Wilo-VeroLine-IPL 100/ /4

Data sheet: Wilo-VeroLine-IPL 100/ /4 Data sheet: Wilo-VeroLine-IPL 1/145-1.5/4 Pump curves 4-pole, 5 Hz H[m] Qmin 1 8 Wilo-VeroLine-IPL 1/175 - Wilo-VeroLine-IPL 1/135 Approved fluids (other fluids on request) Heating water (in accordance

More information

4 submersible pumps powered by renewable energy sources

4 submersible pumps powered by renewable energy sources submersible pumps powered by renewable energy sources ENGLISH TCH technology applied to renewable energy The pumps, owered by renewable energy sources, is a new range coming from the TCH pumps with built-in

More information

Connection. k VS -Value m 3 /h

Connection. k VS -Value m 3 /h 56.108/1 VUF: 2-way valve with male thread, PN16 Features Control valve for continuous control of cold water, and hot water in closed networks. Water quality as per VDI 2035. In combination with valve

More information

4 submersible pumps with integrated electronics powered by renewable energy sources ENGLISH

4 submersible pumps with integrated electronics powered by renewable energy sources ENGLISH submersible pumps with integrated electronics powered by renewable energy sources ENGLISH HS technology applied to renewable energy HS MultiPower pumps (HS MP), powered by renewable energy sources, is

More information

High-efficiency Circulator Pump. HEP Optimo L+ Installation/Operating Manual

High-efficiency Circulator Pump. HEP Optimo L+ Installation/Operating Manual High-efficiency Circulator Pump HEP Optimo L+ Installation/Operating Manual Legal information/copyright Installation/Operating Manual HEP Optimo L+ Original operating manual All rights reserved. The contents

More information

NK40-160/172A1F2AE-SBAQE

NK40-160/172A1F2AE-SBAQE GRUNDFOS DATA BOOKLET NK4-16/172A1F2AE-SBAQE Grundfos pump 9782923 Thank you for your interest in our products. Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/nkbasis/9782923/nk-4-16-172-a1-f-a-e-baqe.html

More information

Data sheet: Wilo-VeroLine-IPL 65/ /2

Data sheet: Wilo-VeroLine-IPL 65/ /2 Data sheet: Wilo-VeroLine-IPL 65/145-5.5/2 Pump curves 2-pole, 5 Hz H[m] 3 25 15 5 Qmin IPL 65/155-5,5/2 Wilo-VeroLine-IPL 65/155 - Wilo-VeroLine-IPL 65/145 IPL 65/145-5,5/2 IPL65/155-7,5/2 5 3 4 5 6 7

More information

Paddle-wheel flow controller for On/Off control

Paddle-wheel flow controller for On/Off control Paddle-wheel flow controller for On/Off control Type 8032 can be combined with... Indication, monitoring, transmitting and On/Off control in one device Programmable outputs (transistor or relay) Automatic-calibration:

More information

Lowara Ecocirc Vario (EV)

Lowara Ecocirc Vario (EV) Lowara Ecocirc Vario (EV) The speed of the pump can be manually regulated to meet the requirement of the system. The software enables a choice from infinite number of performance curves. Spherical Rotor/Stator

More information

TPE N-A-F-A-GQQE

TPE N-A-F-A-GQQE GRUNDFOS DATA BOOKLET TPE2 65-15-N-A-F-A-GQQE Grundfos pump 98438388 Thank you for your interest in our products. Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/tpe/98438388/tpe2-65-15-n-a-f-a-gqqe.html

More information

Data sheet: Wilo-VeroLine-IPL 65/ /2

Data sheet: Wilo-VeroLine-IPL 65/ /2 Data sheet: Wilo-VeroLine-IPL 65/115-1.5/2 Pump curves 2-pole, 5 Hz H[m] 16 14 12 1 8 6 4 2 1 2 3 4 5 2 4 6 8 1 12 14 16 P 2 [kw] 1,6 1,2,8,4 1 2 3 4 5 η p[%] 8 6 Qmin 4 2 1 2 3 4 5 Dimension drawing 8

More information

NB80-160/161 A-F2-A-BQQE

NB80-160/161 A-F2-A-BQQE GRUNDFOS DATA BOOKLET NB8-16/161 A-F2-A-BQQE Grundfos pump 9943539 Thank you for your interest in our products. Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/nbe/9943539/nbe-125-315-275-as-f2-a-e-bqqe.html

More information

NB /263 AS-F2-A-BAQE

NB /263 AS-F2-A-BAQE GRUNDFOS DATA BOOKLET NB125-25/263 AS-F2-A-BAQE Grundfos pump 9832195 Thank you for your interest in our products. Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/nb/9832195/nb-125-25-263-as-f2-a-e-baqe.html

More information

Vertical multi-stage pumps

Vertical multi-stage pumps MK Vertical multi-stage pumps PERFORMANCE RANGE Flow rate up to 180 l/min (10.8 m³/h) Head up to 103 m APPLICATION LIMITS Manometric suction lift up to 7 m Liquid temperature between -10 C and +40 C Ambient

More information

Eco Mixed Flow (emf) Energy Saver. Terminal Box. Performance. Quality Assurance. Impellers. Accessories. Motors

Eco Mixed Flow (emf) Energy Saver. Terminal Box. Performance. Quality Assurance. Impellers. Accessories. Motors Eco Mixed Flow (emf) High efficiency Mixed Flow Fan with guide vanes Available in sizes 355 to 710mm dia. IP54 Fan rating (duct mounted) Operating temperatures up to 80 C (see technical specification)

More information

NKE80-160/175A2F2AE-SBQQE

NKE80-160/175A2F2AE-SBQQE GRUNDFOS DATA BOOKLET NKE8-1/17AFAE-SBQQE Grundfos Pump 99187 Thank you for your interest in our products Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/nkebasis/99187/nke-8-1-17-a-f-a-e-bqqe.html

More information

Simply a question of better measurement

Simply a question of better measurement Simply a question of better measurement Flow sensors for air and gases SCHMIDT Flow Sensors Solutions for measuring technology in practice SCHMIDT Technology is a specialist in the development and production

More information

BUE: 3-way flanged valve, PN 16/10 (el.)

BUE: 3-way flanged valve, PN 16/10 (el.) Product data sheet 56.116 BUE: 3-way flanged valve, PN 16/10 (el.) How energy efficiency is improved Efficient use in continuous control systems Features Continuous control of cold and hot water in closed

More information

Centrifugal fan with highly efficient EC drive motor

Centrifugal fan with highly efficient EC drive motor Centrifugal fan with highly efficient EC drive motor simple and safe application and installation 2 Why HLU? 90 years of experience in the plastics processing market More than 10.000 m² production in Germany

More information

TPED /4-A-F-A-BQQE 3X400 50HZ

TPED /4-A-F-A-BQQE 3X400 50HZ GRUNDFOS DATA BOOKLET TPED 125-3/4-A-F-A-BQQE 3X4 5HZ Grundfos pump 98742617 Thank you for your interest in our products. Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/tped/98742617/tped-125-3-4-a-f-a-bqqe.html

More information

Instruction Sheets for ECM Variable Speed Pumps. AM55 Pages 2-3 AM99 Pages 4-7

Instruction Sheets for ECM Variable Speed Pumps. AM55 Pages 2-3 AM99 Pages 4-7 Instruction Sheets for ECM Variable Speed Pumps AM55 Pages 2-3 AM99 Pages 4-7 Instruction Sheet for High Efficiency, Effective 8/11/15 Variable Speed ECM Circulators Supersedes New AM55 (Einstein) IS-AM09-618

More information

2-port ball valves with flanged connection, PN25

2-port ball valves with flanged connection, PN25 s 4 120 ACVATIX 2-port ball valves with flanged connection, PN25 VAF51.. Gray cast iron EN-GJL-250 (HT250) valve body DN 65...150 k vs 63...360 m 3 /h Angle of rotation 90 Flange connection to ISO 7005-2

More information

Data sheet: Wilo-CronoTwin-DL 65/250-4/4

Data sheet: Wilo-CronoTwin-DL 65/250-4/4 Data sheet: Wilo-CronoTwin-DL 65/25-/ Pump curves -pole - individual operation H[m] 2 2 2 Qmin DL 65/25-3/ Wilo-CronoTwin-DL 65/27 - Wilo-CronoTwin-DL 65/25 DL 65/25-/ DL 65/27-5,5/ Approved fluids (other

More information

Process Multi-Rheo Filter PMRF

Process Multi-Rheo Filter PMRF Process Multi-Rheo Filter PMRF PMRF-1 PMRF-2 PMRF-3 PMRF-5 PMRF-6 PMRF-7 1. Technical Specifications 1.1 General The filter series PMRF (for duplex filters see PMRFD) Process Multi- Rheo Filter completes

More information

COMPONENTS FOR SOLAR THERMAL SYSTEMS

COMPONENTS FOR SOLAR THERMAL SYSTEMS COMPONENTS FOR SOLAR THERMAL SYSTEMS 2012 2 The CALEFFI SOLAR product range has been specially developed for use in solar thermal systems, where high temperatures can normally be reached and where, depending

More information

Data sheet: Wilo-TOP-Z 30/10 (1~230 V, PN 10, RG)

Data sheet: Wilo-TOP-Z 30/10 (1~230 V, PN 10, RG) Data sheet: Wilo-TOP-Z 3/1 (1~23 V, PN 1, RG) Pump curves Single-phase current H/m 9 8 v,5 1 1,5 2 2,5 3 m/s Wilo-TOP-Z 3/1 1~23V - Rp 1¼ Approved fluids (other fluids on request) Drinking water and water

More information

High-efficiency Circulator Pump. Installation/Operating Manual Magneta Smedegaard

High-efficiency Circulator Pump. Installation/Operating Manual Magneta Smedegaard High-efficiency Circulator Pump Installation/Operating Manual Magneta Smedegaard 2 / 60 Legal information/copyright Original operating manual Magneta Smedegaard All rights reserved. The contents provided

More information

ROOF FAN ROOFMASTER STEC

ROOF FAN ROOFMASTER STEC AIR COMFORT AIR MOVEMENT ROOF FANS ROOF FAN ROOFMASTER STEC INSULATED VERSION» TECHNICAL CATALOGUE 2 STEC Roofmaster - Technical Catalogue CONTENTS GENERAL DESCRIPTION Application/specification... 3 Features...

More information

CRE20-08 A-F-A-E-HQQE 3x HZ

CRE20-08 A-F-A-E-HQQE 3x HZ GRUNDFOS DATA BOOKLET CRE2-8 A-F-A-E-HQQE 3x4 6 HZ Grundfos pump 96514642 Thank you for your interest in our products. Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/cre2/96514642/cre-2-8-a-f-a-e-hqqe.html

More information

Boiler Feed Booster Pump YNK. Type Series Booklet

Boiler Feed Booster Pump YNK. Type Series Booklet YNK Type Series Booklet Legal information/copyright Type Series Booklet YNK All rights reserved. The contents provided herein must neither be distributed, copied, reproduced, edited or processed for any

More information

GRUNDFOS DATA BOOKLET SP A, SP. Submersible pumps, motors and accessories 50 Hz

GRUNDFOS DATA BOOKLET SP A, SP. Submersible pumps, motors and accessories 50 Hz GRUNDFOS DATA BOOKLET SP A, SP, motors and accessories 5 Hz Contents General data Performance range Page 3 Applications Page 4 Type key Page 4 Pumped liquids Page 4 Operating conditions Page 4 Curve conditions

More information

TP /2-A-F-A-BQQE 400D 50HZ

TP /2-A-F-A-BQQE 400D 50HZ GRUNDFOS DATA BOOKLET TP 1-36/2-A-F-A-BQQE 4D 5HZ Grundfos pump 9619194 Thank you for your interest in our products. Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/tp/9619194/tp-1-36-2-a-f-a-bqqe.html

More information

Norm-Centrifugal Pumps PN 10

Norm-Centrifugal Pumps PN 10 Norm-Centrifugal Pumps PN 10 Pump dimensions acc. to DIN EN 733 with additional sizes Technical requirements acc. to DIN ISO 9908 Application For pumping pure water, industrial water, sea water, condensate,

More information

Tapflo - your reliable pumpchoice

Tapflo - your reliable pumpchoice Tapflo - your reliable pumpchoice Tapflo - your reliable pumpchoice With experience from industrial fluid handling and pump manufacture since 1970, we know what you as a customer require from an industrial

More information