1 dynacon floor heating manifold with automatic flow control Pressurisation & Water Quality Balancing & Control Thermostatic Control EnGInEERInG advantage

2 Dynacon Description HEIMEIER Dynacon floor heating manifold with automatic flow controllers in supply pipe for each individual heating circuit. Thermostatic inserts with M 0 x. connection in return flow. Matching all HEIMEIER actuators. Stainless steel manifold with flat-sealing connection, union nut. Pipe socket spacing, heating circuits, 0 mm. / manual bleeder, self-sealing. Drain with / hose connection. Wall holder with soundproofing, including mounting material. / Eurokonus pipe connections, suitable for HEIMEIER compression fittings. The following manifold connection kits are available: - Connection kit with Globo ball valves - Connection kit with TBV control valve and Globo ball valve - Connection kit with Zeparo Vent air separator in supply pipe and Zeparo Dirt sludge separator in return - Connection kit with Globo ball valve, including spacer for heat meter in return and Globo ball valve with connection for direct measurement in supply pipe. - Connection kit fixed value control station with high-efficiency pump for controlling the supply temperature. Manifold boxes available as surface-mounted and flush-mounted versions. Assembly Flow controller. Setting cap with blocking ring. Maintenance-free O-ring seal. Manifold 7. Adjustment spindle. Compression spring 8. Sleeve. Cartridge 9. Control element. Connection nipple for heating circuit Automatic hydraulic balancing by direct setting of required flow rate Time and cost-saving commissioning solution Control cartridge ensures constant flow rate Set up and forget Flow rate easily adapted to different heating loads Optimum temperature distribution Saves energy Increased comfort Application Dynacon adjusts the flow rate in the individual heating circuits directly in l/h. This means hydraulic balancing is achieved in one simple operation. The set flow rate is constantly adapted, i.e. if the rate becomes too high, e.g. due to closing adjacent circuits, Dynacon controls the flow automatically to the set value. The control cartridge always ensures a constant flow. This makes Dynacon heating circuit manifolds a time and cost-saving solution especially for system commissioning. With conventional heating circuit manifolds with throttle valves and flow indicators setting the required water quantities is a time-consuming affair. The setting required at the throttle valves must either be calculated or set using flow indicators at the manifold. However, the quantities of water distributed in this way only correspond to maximum requirements. When individual heating circuits are turned off, the quantity of water no longer required is distributed over the adjacent circuits resulting in an oversupply in these circuits. The automatic hydraulic balance with Dynacon avoids this oversupply in individual heating circuits. This ensures optimum temperature distribution, saves energy and increases comfort.

3 Application example Technical data Flow rate range per heating circuit: 0-00 l/h max. min. Calculation example: Target: Set value of Dynacon flow controller Given: Heat flow, heating circuit º = 0 W Temperature spread Δt = 8 K (/ C) Solution: Mass flow ª = º / (c Δt) = 0 / (. 8) = 0 kg/h Flow regulator setting at Dynacon manifold: 0 l/h l/h kpa Minimum differential pressure via flow regulator: 0 - kpa depending on target value

4 Article numbers Dynacon underfloor heating circuit manifold with automatic flow control Heating circuits Connection kit with Globo ball valves with red end cap in infeed and blue end cap in return Connection kit with TBV control valve and Globo ball valve including measuring nipple for measuring differential pressure and flow rate Connection kit with Zeparo Vent air separator in infeed and Zeparo Dirt sludge separator in return S-connection For connection kit. Installation aid for return in manifold boxes

5 Connection kit with Globo ball valve, including spacer for heat meter in return Globo ball valve with connection for direct measurement in infeed Connection kit, fixed value control station with high-efficiency pump Manifold boxes Flush-mounted box, installation depth 0-0 mm Size W x H 90 x 70 mm x 70 mm x 70 mm x 70 mm ,0 x 70 mm ,7 x 70 mm Manifold boxes Surface-mounted box, installation depth 0 mm Size W x H 9 x 0 mm x 0 mm x 0 mm x 0 mm ,0 x 0 mm ,8 x 0 mm Accessories Manual control cap for all HEIMEIER thermostatic valve bodies. With direct connection and end cover, white. Length compensator For holding plastic, copper, precision steel or composite pipes. For valves with G / male thread connection. Nickel-plated brass. L 0-0. G/ x G/ G/ x G/

6 Compression fitting for plastic pipe. Nickel-plated brass. Adaptor - G / male thread. Ø pipe x -. x -. 7x -7. 8x -8. 0x -0. Compression fitting for copper or precision steel pipes. Adaptor - G / male thread. Nickel-plated brass. Metal-to-metal joint. Support bushes must be used for pipes with 0.8 mm thick walls. Observe data provided by pipe manufacturer. Support bush for copper and precision steel pipe with a wall thickness of mm. Brass. Ø pipe L Ø pipe Compression fitting for copper or precision steel pipes. Soft sealing. Nickel-plated brass. Adaptor - G / male thread. Ø pipe Compression fitting for composite pipe. Nickel-plated brass. Adaptor - G / male thread. Ø pipe x -. Screw connection For holding plastic, copper, precision steel or composite pipes. Nickel-plated brass. L G/ x R/ -.08 Double nipple on both sides, for holding plastic, copper, precision steel or composite pipes. Nickel-plated brass. G/ x G/ Automatic flow control insert Spare insert

7 floor heating manifold - dynacon Dimensions - manifold and connection kits Set Set Set + Set Set + Set Set Set Heating circuit manifold, heating circuits Length [mm] Length, including kit + 0 mm bend Length, including kit + 0 mm bend Length, including kit and kit + 0 mm bend Length, including kit and kit + 0 mm bend Length, including kit + 0 mm bend Length, including kit Fixed value control station Supplied without bend 7

8 Dimensions - manifold boxes 90-90/ / Size W x H [mm] Size W x H [mm] Surface-mounted box, installation depth 0 mm Flush-mounted box, installation depth 0-0 mm 9 x 0 90 x 70 8 x 0 7 x 70 7 x 0 7 x x 0 87 x 70 0 x 0 0 x 70 8 x 0 7 x 70 The products, texts, photographs, graphics and diagrams in this document may be subject to alteration by TA Hydronics without prior notice or reasons being given. For the most up to date information about our products and specifications, please visit partner in your country

Floor heating manifold with automatic flow control

Floor heating manifold with automatic flow control dynacon Floor heating manifold with automatic flow control Pressurisation & Water Quality Balancing & Control Thermostatic Control EnGInEERInG advantage dynacon adjusts the flow rate in the individual

More information

Dynacon. Floor Heating Manifolds Floor heating manifold with automatic flow control

Dynacon. Floor Heating Manifolds Floor heating manifold with automatic flow control Dynacon Automatic Flow Control Floor Heating Manifolds Floor heating manifold with automatic flow control IMI HEIMEIER / Floor Heating Control / Dynacon Dynacon Dynacon adjusts the flow rate in the individual

More information

three-way mixing valve

three-way mixing valve three-way mixing valve with or without presetting, for heating and cooling systems. Pressurisation & Water Quality alancing & Control Thermostatic Control engineering avantage Three-way mixing valve, with

More information

RTL. Floor Heating Controller Return temperature limiter with and without presetting

RTL. Floor Heating Controller Return temperature limiter with and without presetting RTL Floor Heating Controller Return temperature limiter with and without presetting IMI HEIMEIER / Floor Heating Control / RTL RTL Among other things, the return temperature limiter RTL is used to limit

More information

Mikrotherm F. Manual Radiator Valves With presetting

Mikrotherm F. Manual Radiator Valves With presetting Mikrotherm F Manual Radiator Valves With presetting IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Mikrotherm F Mikrotherm F The Mikrotherm F manual radiator valve is used in warm water pump heating

More information

Thermostatic radiator valves with presetting

Thermostatic radiator valves with presetting Thermostatic radiator valves TRV-2, TRV-2S Thermostatic radiator valves with presetting Pressurisation & Water Quality Balancing & Control Thermostatic Control ENGINEERING AVANTAGE Thermostatic radiator

More information

Regutec F. Return Lockshield Radiator lockshield

Regutec F. Return Lockshield Radiator lockshield Regutec F Return Lockshield Radiator lockshield IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Regutec F Regutec F The Regutec lockshield is used in pumped warm water heating and air conditioning

More information

Pressure independent balancing and control valve For ON/OFF control

Pressure independent balancing and control valve For ON/OFF control KT 512 Pressure independent balancing and control valve For ON/OFF control Pressurisation & Water Quality Balancing & Control Thermostatic Control ENGINEERING ADVANTAGE High-performing and compact, these

More information

TA-Mini-Fast-Fit. Prefab units Fabricated solutions for small terminal units

TA-Mini-Fast-Fit. Prefab units Fabricated solutions for small terminal units TA-Mini-Fast-Fit Prefab units Fabricated solutions for small terminal units IMI TA / Control valves / TA-Mini-Fast-Fit TA-Mini-Fast-Fit Compact pressure independent solution for modulating or on/off control.

More information

TA-6-way valve. Standard control valves 6-way valve for change-over systems

TA-6-way valve. Standard control valves 6-way valve for change-over systems TA-6-way valve Standard control valves 6-way valve for change-over systems IMI TA / Control valves and Actuators / TA-6-way valve TA-6-way valve The 6-way valve solution enables various control set-ups

More information

RADIATOR VALVE ACCESSORIES

RADIATOR VALVE ACCESSORIES RADIATOR VALVES ACCESSORIES RADIATOR VALVES CONTENTS Accessories and spare parts: Presetting tools Radiator connections Other connections (FPL, FPL-PX, KOMBI - see each catalogue leaflet) Radiator unions

More information

Pressure independent combined control and balancing valves with independent EQM characteristics

Pressure independent combined control and balancing valves with independent EQM characteristics Combined control & balancing valves TA-FUS1ON-P Pressure independent combined control and balancing valves with independent EQM characteristics Pressurisation & Water Quality Balancing & Control Thermostatic

More information

Distributor for Floor Heating Systems

Distributor for Floor Heating Systems Distributor for Floor Heating Systems Dimension 1 1 /4" Standard Sheet for 8512 Edition 0700 (1299) 2-way, 3-way, and 4-way distributors with O-ring seal in the distributor coupling area, suitable for

More information

Pressure independent balancing and control valve

Pressure independent balancing and control valve Pressure independent balancing and control valves KTM 512 Pressure independent balancing and control valve Pressurisation & Water Quality Balancing & Control Thermostatic Control ENGINEERING ADVANTAGE

More information

DA 50. Differential pressure controllers Adjustable set-point

DA 50. Differential pressure controllers Adjustable set-point DA 50 Differential pressure controllers Adjustable set-point IMI TA / Differential pressure controllers / DA 50 DA 50 These differential pressure controllers for heating and cooling systems are particularly

More information

TDU.3 floor distribution unit SK

TDU.3 floor distribution unit SK SK General description and application The is intended for two pipe horizontal heating systems and includes connecting, measuring, regulating and distribution functions. The TDU.3 is easily installed on

More information

HERZ 7217 V. Integral Fixed Orifice Control Valve HERZ 7217 V. Data sheet 7217 V, Issue Size in mm. STRÖMAX Fig No DN L Lm Rp H SW kv kvs

HERZ 7217 V. Integral Fixed Orifice Control Valve HERZ 7217 V. Data sheet 7217 V, Issue Size in mm. STRÖMAX Fig No DN L Lm Rp H SW kv kvs HERZ 7217 V Integral Fixed Orifice Control Valve Data sheet 7217 V, Issue 1011 Size in mm STRÖMAX Fig No DN L Lm Rp H SW kv kvs TS-V LF 1 7217 50 15 83 28,5 1/2 41 27 0,07-0,45 0,48 TS-V MF 1 7217 59 15

More information

Art.918C Pre-assembled manifold with flow meters, air

Art.918C Pre-assembled manifold with flow meters, air TECHNICAL CATALOGUE Art.98C Pre-assembled manifold with flow meters, air vent valves and drain cock TEC ITAP SpA, founded in Lumezzane (Brescia) in 97, is currently one of the leading production companies

More information

CALEFFI. Distribution manifold for radiant panel systems. 664 series 01260/14 GB

CALEFFI. Distribution manifold for radiant panel systems. 664 series 01260/14 GB Distribution manifold for radiant panel systems 664 series ACCREDITED CALEFFI 01260/14 GB ISO 9001 FM 21654 ISO 9001 No. 0003 Function The distribution manifold for radiant panel systems is used to optimally

More information

COMPONENTS FOR SOLAR THERMAL SYSTEMS

COMPONENTS FOR SOLAR THERMAL SYSTEMS COMPONENTS FOR SOLAR THERMAL SYSTEMS The Caleffi Solar product range has been specially developed for use in solar thermal systems, where high temperatures can normally be reached and where, depending

More information

EMO T. Actuators High performance thermoelectric actuator For ON/OFF or PWM control

EMO T. Actuators High performance thermoelectric actuator For ON/OFF or PWM control EMO T Actuators High performance thermoelectric actuator For ON/OFF or PWM control IMI TA / Actuators / EMO T EMO T Used in conjunction with small terminal valves e.g. TBV-C and TA-COMPACT-P or thermostatic

More information

Automatic balancing valves ASV-PV DN (3rd gen.)

Automatic balancing valves ASV-PV DN (3rd gen.) Automatic balancing valves ASV-PV DN 50-100 (3rd gen.) Description / Application Partner valve ASV-PV DN 50 ASV-PV DN 65-100 MSV-F2 DN 50-100 ASV balancing valves are used for dynamic hydronic balance

More information

TA-FUS1ON-P. Combined control & balancing valves Pressure independent combined balancing and control valves with independent EQM characteristics

TA-FUS1ON-P. Combined control & balancing valves Pressure independent combined balancing and control valves with independent EQM characteristics TA-FUS1ON-P Combined control & balancing valves Pressure independent combined balancing and control valves with independent EQM characteristics IMI TA / Control valves / TA-FUS1ON-P TA-FUS1ON-P These innovative

More information

System Components. Potable water Distributors, wall boxes and connections

System Components. Potable water Distributors, wall boxes and connections System Components Potable water Distributors, wall boxes and connections IMI TA / Couplings / System Components System Components For tap water and heating systems with crosslinked polyethylene pipes (PEX).

More information

CALEFFI. Pre-assembled distribution manifolds for. heating and air-conditioning systems. 663 series 01065/18 GB. replaces dp 01065/06 GB.

CALEFFI. Pre-assembled distribution manifolds for. heating and air-conditioning systems. 663 series 01065/18 GB. replaces dp 01065/06 GB. Pre-assembled distribution manifolds for heating and air-conditioning systems 663 series FM 21654 003 065/18 GB replaces dp 065/06 GB Function The pre-assembled distribution manifolds are designed to optimise

More information

savings flexibility recyclable LIGHTNESS FULL FLOW MECHANICAL STRENGTH IMPROVE CONTROL TECHNICAL BROCHURE aesthetic performance CHANGE

savings flexibility recyclable LIGHTNESS FULL FLOW MECHANICAL STRENGTH IMPROVE CONTROL TECHNICAL BROCHURE aesthetic performance CHANGE TECHNICAL BROCHURE aesthetic performance flexibility thermal comfort PREMIUM QUALITY MECHANICAL STRENGTH IMPROVE CHANGE LIGHTNESS savings high resistance to corrosion low and high temperature systems FULL

More information

Manifold Isolation Valves

Manifold Isolation Valves 300 N. Opdyke Rd. Introduction The Stainless Manifolds are designed for use in Hydronic radiant panel heating and cooling applications. They are available in various sizes, configurations, and options

More information

HERZ-Motorised flow controler

HERZ-Motorised flow controler HERZ-Motorised flow controler Control and regulating valve Data sheet 4006 SMART, Issue 0516 Dimensions in mm 4006 M 4006 R M R Order number DN G L L1 B B1 H without Actuator H with Actuator H1 1 4006

More information

M-8100EP. Installation Guide ENGINEERED PLASTIC MANIFOLD SERIES. Introduction. A. Assemble Manifold Components

M-8100EP. Installation Guide ENGINEERED PLASTIC MANIFOLD SERIES. Introduction. A. Assemble Manifold Components Introduction The Pro Manifolds with Integrated adaptor are designed for use in Hydronic radiant panel heating and cooling applications. They are available in various sizes, configurations, and options

More information

Combined automatic balancing valve AB-PM valve DN 10-32, PN 16

Combined automatic balancing valve AB-PM valve DN 10-32, PN 16 Data sheet Combined automatic balancing valve AB-PM valve DN 10-32, PN 16 Description AB-PM is a combined automatic balancing valve. It features three function in compact valve body: 1. Differential pressure

More information

PRESSURE CONTROL VALVES SABS 198

PRESSURE CONTROL VALVES SABS 198 PRESSURE CONTROL VALVES SABS 198 1 CALVALVE DOUBLE BLOCK Pressure control combined pressure reducing valve and expansion relief valve, copper by copper compression ends. DZR alloy body. Replaceable cartridge

More information

EMO TM. Actuators High performance proportional actuator For modulating control

EMO TM. Actuators High performance proportional actuator For modulating control EMO TM Actuators High performance proportional actuator For modulating control IMI TA / Actuators / EMO TM EMO TM A proportional thermoelectric actuator which, when used together with the TA-Modulator,

More information

EMOtec. Actuators Thermal actuator for heating, ventilation, and air conditioning systems

EMOtec. Actuators Thermal actuator for heating, ventilation, and air conditioning systems EMOtec Actuators Thermal actuator for heating, ventilation, and air conditioning systems IMI HEIMEIER / Thermostats & Actuators / EMOtec EMOtec The EMOtec thermal actuator with position indicator (NC)

More information

CALEFFI. Distribution manifold for radiant panel systems. 664 series 01260/18 GB. replaces 01260/14 GB

CALEFFI. Distribution manifold for radiant panel systems. 664 series 01260/18 GB. replaces 01260/14 GB Distribution manifold for radiant panel systems 664 series FM 21654 003 CALEFFI 01260/18 GB replaces 01260/14 GB Function The distribution manifold for radiant panel systems is used to optimally distribute

More information

The valves can be controlled electronically by thermal actuators or act as self-acting units by means of remote temperature adjusters.

The valves can be controlled electronically by thermal actuators or act as self-acting units by means of remote temperature adjusters. Floor Heating Manifold FHF Application The Manifold FHF is used for controlling water flow in under floor heating systems. Each tube of the floor heating system is connected to the manifold, thus making

More information

MrPEX 1 ½ " Brass Manifold Installation Guide

MrPEX 1 ½  Brass Manifold Installation Guide MrPEX 1 ½ " Brass Manifold Installation Guide Design MrPEX 1 ½" Brass Manifold is made from high quality alloy extruded and chrome plated after machining, and is offered in 2 through 12 loop configurations.

More information

LK Manifold Shunt VS2

LK Manifold Shunt VS2 LK Manifold Shunt VS2 Design LK Manifold Shunt VS2 is a shunt unit with a two way control valve used in systems with a primary pump. The shunt unit is mountable from both the left and right of LK Manifolds.

More information

Zeparo G-Force. Automatic air vents and separators Microbubble, dirt and magnetite separator with Cyclonic technology

Zeparo G-Force. Automatic air vents and separators Microbubble, dirt and magnetite separator with Cyclonic technology Zeparo G-Force Automatic air vents and separators Microbubble, dirt and magnetite separator with Cyclonic technology IMI PNEUMATEX / Air Vents, Dirt Separators and Degassing / Zeparo G-Force Zeparo G-Force

More information

RADIATOR VALVES / RADIATOR VALVES WITH PRESETTING

RADIATOR VALVES / RADIATOR VALVES WITH PRESETTING RAIATOR VAVES / RAIATOR VAVES WITH PRESETTING THERMOSTATIC RAIATOR VAVES WITH PRESETTING Thermostatic radiator valve primary for radiators in heating systems and secondary for small cooling terminals.

More information

FCU Floor Control Unit

FCU Floor Control Unit Fully assembled with integrated M3V Control Group including mixing valve and circulating pump and in-line high and low temperature Topway T2 FM manifold options with high and low temperature manifold options

More information

CT3202.0_01 EN February 2018

CT3202.0_01 EN February 2018 UNDERFLOOR HEATING / RADIATOR HEATING COMPACT BRASS MODULAR MANIFOLDS (centre distance 37 mm) CT3202.0_01 EN February 2018 o o o Super compact: e.g. 11 ways (version code 3211.06.10) in just 60 cm; Insertion

More information

COMPONENTS FOR SOLAR THERMAL SYSTEMS

COMPONENTS FOR SOLAR THERMAL SYSTEMS COMPONENTS FOR SOLAR THERMAL SYSTEMS 2012 2 The CALEFFI SOLAR product range has been specially developed for use in solar thermal systems, where high temperatures can normally be reached and where, depending

More information

Connectors Content. Connectors at a glance Screw connectors and plug-in connectors - Standard

Connectors Content. Connectors at a glance Screw connectors and plug-in connectors - Standard Connectors Content Connectors at a glance... 264 Screw connectors and plug-in connectors - Standard... 266 Screw connectors and plug-in connectors - self-extinguishing... 276 Screw connectors and plug-in

More information

Application technology, 5th edition. Volume III: Fonterra radiant heating and cooling

Application technology, 5th edition. Volume III: Fonterra radiant heating and cooling Application technology, 5th edition Volume III: Fonterra radiant heating and cooling Regulation components, manifolds and manifold cabinets Regulation components, manifolds and manifold cabinets System

More information

VCL : 2-way regulating valve for dynamic hydronic balancing, PN 16, Valveco

VCL : 2-way regulating valve for dynamic hydronic balancing, PN 16, Valveco Product data sheet 6.1 57.001 VCL 010 032: 2-way regulating valve for dynamic hydronic balancing, PN 16, Valveco How energy efficiency is improved Automatic dynamic hydronic balancing with the SAUTER Valveco

More information

MrPEX 1 ¼ Stainless Steel Manifold. Installation Guide

MrPEX 1 ¼ Stainless Steel Manifold. Installation Guide MrPEX 1 ¼ Stainless Steel Manifold Installation Guide Design MrPEX 1 ¼ Stainless Steel Manifold is made from high quality stainless steel, and is offered in 2 through 12 loop configurations. The manifold

More information

SECTION PIPING SPECIALTIES PART 1 GENERAL 1.1 SUMMARY

SECTION PIPING SPECIALTIES PART 1 GENERAL 1.1 SUMMARY SECTION 230533 - PIPING SPECIALTIES PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Pressure gages. 2. Pressure gage taps. 3. Thermometers. 4. Thermometer supports. 5. Test plugs. 6. Static pressure

More information

T2 Wall Hung Radiator & UFH Manifolds

T2 Wall Hung Radiator & UFH Manifolds T Wall Hung Radiator & UFH Manifolds T Topway LS Pre-Assembled Heating Manifold A range of nickel plated extruded brass manifolds pre-assembled for immediate installation for both radiator and underfloor

More information

4-way Distribution Valve

4-way Distribution Valve 4-way Distribution Valve for one- and two-pipe systems Product specification sheet Application 4-way distribution valves are used to connect supply and return of a radiator to the corresponding pipes of

More information

KTM 512. Union threads/ansi flanges. Combined control & balancing valves Pressure independent balancing and control valve DN

KTM 512. Union threads/ansi flanges. Combined control & balancing valves Pressure independent balancing and control valve DN KTM 512 Union threads/ansi flanges Combined control & balancing valves Pressure independent balancing and control valve DN 15-125 IMI TA / Control valves / KTM 512 Union threads/ansi flanges KTM 512 Union

More information

Wall-mounted device ET / 1. Chlorinator C Improved changes are always reserved without notice. JESCO DOSIERTECHNIK GmbH & Co.

Wall-mounted device ET / 1. Chlorinator C Improved changes are always reserved without notice. JESCO DOSIERTECHNIK GmbH & Co. Wall-mounted device ET 2 02 25 / 1 ET 2 02 25 / 2 Item Description Qty. 5 kg/h 10 kg/h 15 kg/h 25 kg/h 1 Vacuum regulator C2525-V 1 20231834 (see ET 2 02 25 / 5) 2 Backpressure regulator C2525-H 1 20231835

More information

Ballorex Venturi 3.1 Introduction

Ballorex Venturi 3.1 Introduction 3.1 Introduction Venturi Fixed Orifice Double Regulating Valve (FODRV) DN 15-600 1/2-24 Venturi description The Venturi is a range of manual balancing valves used in water-based heating and cooling systems

More information

1/2" /4" " /4" 1 1 /4"

1/2 /4  /4 1 1 /4 Standard Sheet for Circuit Control Valve 4117 R Edition 1000 (0999) 4117 R Article R R1 L H Number Connection Open 4117 R Order Number 1/2" 65 97 1 4117 61 3/4" 70 109 1 4117 62 1" 85 112 1 4117 63 1/4"

More information

KAN-therm System. Series 71A, 75A, 51A, 55A manifolds. installation and maintenance instructions

KAN-therm System. Series 71A, 75A, 51A, 55A manifolds. installation and maintenance instructions instrukcja_rozdzielacz71a-55a_pl_ru_en:print 2010-09-30 14:14 Strona 25 KAN-therm System Series 71A, 75A, 51A, 55A manifolds installation and maintenance instructions Series 71A and 75A manifolds Installation

More information

Pressure operated water valve Type WVFX and WVS

Pressure operated water valve Type WVFX and WVS Data sheet Pressure operated water valve WVFX and WVS Pressure operated water valves types WVFX and WVS are used for regulating the flow of water in refrigeration plants with water-cooled condensers. The

More information

M Installation Guide. PRECISION Manifold Series. Introduction. A. Assemble Manifold Components

M Installation Guide. PRECISION Manifold Series. Introduction. A. Assemble Manifold Components Page 1 Introduction The M-8200 Precision Manifolds are designed for use in Hydronic radiant panel heating and cooling applications. They are available in various sizes, configurations, and options with

More information

TECHNICAL CATALOGUE DISTRIBUTION MANIFOLDS

TECHNICAL CATALOGUE DISTRIBUTION MANIFOLDS TECHNICAL CATALOGUE DISTRIBUTION TEC ITAP SpA, founded in Lumezzane (Brescia) in 972, is currently one of the leading production companies in Italy of valves, fittings and distribution manifolds for plumbing

More information

1. Main structure. Main structure Jet-288 Exploded views. Bearings and impeller shaft

1. Main structure. Main structure Jet-288 Exploded views. Bearings and impeller shaft Main structure 1. Main structure Code 288A 288C 288D 288E 288F 288G 288H 288I A B Name Frame Bearings and impeller shaft Impeller Stator Steering nozzle Reversing deflector Hydraulic cylinder Hydraulic

More information

Fittings threads: metric (M5), BSP (G1/8, G1/4, G3/8, G1/2, G3/4, G1), BSPT (R1/8, R1/4, R3/8, R1/2, R3/4, R1)

Fittings threads: metric (M5), BSP (G1/8, G1/4, G3/8, G1/2, G3/4, G1), BSPT (R1/8, R1/4, R3/8, R1/2, R3/4, R1) > Series 2000 pipe fittings Series 2000 pipe fittings Fittings threads: metric (M5), BSP (G1/8, G1/, G3/8, G1/2, G3/, G1), BSPT (R1/8, R1/, R3/8, R1/2, R3/, R1) The wide range of Camozzi pipe fittings,

More information

Products for underfloor heating

Products for underfloor heating ENG Products for underfloor heating Hydronic Solutions 1 Table of Contents LK 420 Minishunt... 3 LK 421 Manifold Shunt... 4 LK 422 Manifold Shunt... 5 Spare Parts and Accessories... 6 LK 430 Manifold...

More information

1. Main structure. Main structure Exploded views, AJ 288. Bearings and impeller shaft

1. Main structure. Main structure Exploded views, AJ 288. Bearings and impeller shaft Main structure 1. Main structure Code 288A 288C 288D 288E 288F 288G 288H 288I A B Name Body Bearings and impeller shaft Impeller Stator Steering nozzle Reversing deflector Hydraulic cylinder Hydraulic

More information

LK Manifold Shunt VS 2-2,5

LK Manifold Shunt VS 2-2,5 LK Manifold Shunt VS 2-2,5 Design LK Manifold Shunt VS (Variable Speed) is a water temperature control pack complete with two way control valve used in systems with a primary pump. The shunt unit is mountable

More information

MANIFOLDS & WATER TEMPERATURE CONTROL

MANIFOLDS & WATER TEMPERATURE CONTROL MANIFOLDS & WATER TEMPERATURE CONTROL Overview Water based underfloor heating (UFH) systems work by turning the entire floor into one large low temperature radiator which is heated via a network of pipes

More information

Flow-compensated temperature controller AVTQ DN 15

Flow-compensated temperature controller AVTQ DN 15 Data sheet Flow-compensated temperature controller AVTQ DN 15 Description AVTQ is a self-acting flow-compensated temperature controller primarily for use in district heating systems with plate heat exchangers

More information

CHOOSING YOUR MANIFOLD & LOCATION

CHOOSING YOUR MANIFOLD & LOCATION CHOOSING YOUR MANIFOLD & LOCATION THOUGHTS ON ZONING The function of a manifold is to distribute the correct flow to each loop to meet its specific heating load. This is achieved by balancing each loop

More information

VDL : 2-way regulating valve for dynamic hydronic balancing, PN 25, Valveco compact

VDL : 2-way regulating valve for dynamic hydronic balancing, PN 25, Valveco compact Product data sheet 9.1 7.003 VDL 010...00: 2-way regulating valve for dynamic hydronic balancing, PN 2, Valveco compact How energy efficiency is improved Automatic dynamic hydronic balancing with the SAUTER

More information

Manifold Valve Accessories

Manifold Valve Accessories Accessories Manifold Valve Accessories DIELECTRIC KITS The dielectric kit is designed to maintain the integrity and reliability of the pipeline and piping system through safety and corrosion protection.

More information

TA-6-way valve. NPT threads. Standard control valves 6-way valve for change-over systems

TA-6-way valve. NPT threads. Standard control valves 6-way valve for change-over systems T-6-way valve NPT threads Standard control valves 6-way valve for change-over systems IMI T / Control valves / T-6-way valve NPT threads T-6-way valve NPT threads The 6-way valve solution enables various

More information

Section 1 - Sanitary Manifolds

Section 1 - Sanitary Manifolds Topway SN WRAS approved nickel plated extruded brass manifold in ¾, 1 and 1¼ sizes, and DN20 outlets Available with ½ F outlets for connection to alternative pipe types Available in from 2 to 12 ways per

More information

Fan-coil valves Series

Fan-coil valves Series Fan-coil valves Series 11-11 - 411 Main features Complete range in the following versions : -way - DN: 1/, /4, 1 -way - DN: 1/, /4, 1 -way with 4 ports - DN: 1/, /4 - The -way version and the -way versions

More information

Buy Karcher Parts Online: Need Technical Help? Call: Requests to:

Buy Karcher Parts Online:  Need Technical Help? Call: Requests to: Karcher Model: K 2400 HH ( 59588240 ) - Parts Section:1.0 PIECE PARTS Page 1 of 13 2 91823530 2 CONTROL KNOB 3 91963040 2 SAUCER-HEAD SCREW 5 91834010 2 RUBBER BUFFER 6 91963080 2 BOLT 7 91820040 2 CAP

More information

Balancing Basics. Mike Weisman, ASHRAE Treasurer. ASHRAE Golf Outing: May 18 th, 2018! HEATHERWOODE

Balancing Basics. Mike Weisman, ASHRAE Treasurer. ASHRAE Golf Outing: May 18 th, 2018! HEATHERWOODE Balancing Basics Mike Weisman, ASHRAE Treasurer ASHRAE Golf Outing: May 18 th, 2018! HEATHERWOODE Agenda: Why balance? Manual Balancing Valves Manual Balancing Process Automatic Flow Controllers Partial

More information

IsoTherm FlowGuards Mini Ball Valves Gauges Aquastats Unions

IsoTherm FlowGuards Mini Ball Valves Gauges Aquastats Unions 82 IsoTherm FlowGuards Mini Ball Valves Gauges Aquastats Unions 83 Adjustment knob (sets supply temperature) Mixing Valve 1 Male BSP Threads Mixing Point Supply Inlet from Boiler Temperature Gauge (indicates

More information

BLAST MACHINES - SYSTEMS -

BLAST MACHINES - SYSTEMS - BLAST MACHINES - SYSTEMS - 10019 SYSTEM-3 System with ABSC-1028-17 litre Blast Machine THE SYSTEM-3 INCLUDES: Blast machine ABSC-1028 (17 litre), remote control system ARC-50-H, moisture separator CLEARLINE-½",

More information

V2880, Therafix Design Thera Design Edition - H-Block with TRV Insert WITH HIGH QUALITY SURFACE FOR DESIGN RADIATORS

V2880, Therafix Design Thera Design Edition - H-Block with TRV Insert WITH HIGH QUALITY SURFACE FOR DESIGN RADIATORS W GE R MAN Y W GE R MAN Y V2880, Therafix Design Thera Design Edition - H-Block with TRV Insert WITH HIGH QUALITY SURFACE FOR DESIGN RADIATORS Design Angle left Straight W GE R MAN Y Angle right The Therafix

More information

Tour b Andersson AB THERMOSTATICALLY CONTROLLED RADIATOR VALVE RVT

Tour b Andersson AB THERMOSTATICALLY CONTROLLED RADIATOR VALVE RVT Tour b Andersson AB THERMOSTATICALLY CONTROLLED RADIATOR VALVE RVT The RVT thermostatically controlled radiator valve is intended for use with 2-pipe pump-circulated hot water systems and is very effective

More information

PS Powder Sieve Machine

PS Powder Sieve Machine Spare Parts List Issued 07/95 PS Powder Sieve An ITW Company 7 Spare Parts List 7.1 Ordering Spare Parts When ordering spare parts for powder coating equipment, please indicate the following specifications

More information

Globo P. Ball valves Pump ball valve made of gunmetal

Globo P. Ball valves Pump ball valve made of gunmetal Globo Ball valves ump ball valve made of gunmetal IMI EIMEIER / Shut-off valves / Globo Globo Globo and Globo -S are used in pump warm water heating systems for direct connection to circulating pumps with

More information

Buy Karcher Parts Online: Need Technical Help? Call: Requests to:

Buy Karcher Parts Online:  Need Technical Help? Call: Requests to: Page 1 of 12 Karcher Model:HD 3000 MTD ( 59588400 ) - Parts Section:1.0 PIECE PARTS 1 91825140 1 BOLT 2 91823530 2 CONTROL KNOB 3 91963010 2 SCREW 5 91834050 2 RUBBER BUFFER 6 91963080 2 BOLT 7 91825060

More information

FCU 6-PORT PICV VALVE SET MODULE BROCHURE

FCU 6-PORT PICV VALVE SET MODULE BROCHURE FCU 6-PORT PICV VALVE SET MODULE BROCHURE Copyright. February 2019 FLOCONTROL DESIGNS AND ASSEMBLES BESPOKE FCU VALVE SETS TO ADDRESS PROJECT-SPECIFIC REQUIREMENTS FloControl offers a comprehensive range

More information

Components for central heating

Components for central heating 01 01 Components for central heating Booster units and spare parts 18 Hydraulic separator and spare parts 21 Dirt separators - Deaerators 23 By-Pass differential valve - Air separator units 32 Filling

More information

Guide Specification SECTION HYDRONIC PIPING SPECIALTIES PART 1 - GENERAL 1.1 SUMMARY

Guide Specification SECTION HYDRONIC PIPING SPECIALTIES PART 1 - GENERAL 1.1 SUMMARY SECTION 23 21 16 - HYDRONIC PIPING SPECIALTIES PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Pressure gages. 2. Pressure gage taps. 3. Thermometers. 4. Thermometer supports. 5. Test plugs. 6. Air

More information

underfloor heating PRODUCTS FOR UNDERFLOOR HEATING

underfloor heating PRODUCTS FOR UNDERFLOOR HEATING underfloor heating PRODUCTS FOR UNDERFLOOR HEATING Table of Contents LK 420 Minishunt... 3 LK 421 Manifold Shunt... 4 LK 422 Manifold Shunt... 5 Spare Parts and Accessories... 6 LK 430 Manifold... 7 LK

More information

Zoom and Print Options

Zoom and Print Options 1 of 63 8/26/2017, 7:04 AM Vehicle» Transmission and Drivetrain» Transfer Case» Service and Repair» Procedures» Isuzu T150» Overhaul (Unit Repair)» 1. Transfer Case Disassemble Transfer Case Disassemble

More information

LK Manifold RF. Design. Requirements

LK Manifold RF. Design. Requirements LK Manifold RF Design LK Manifold RF is made of stainless steel, the variants having 1 to 12 floor heating circuits. The manifold is delivered pre-mounted in brackets. The manifold has thermometers on

More information

K35 HeatBloC with 3-temperature mixing valve

K35 HeatBloC with 3-temperature mixing valve PAW GmbH & Co. KG Böcklerstr. 11, D-31789 Hameln, Germany Phone: +49-5151-9856-0, Fax: +49-5151-9856-98 E-mail: info@paw.eu, Web: www.paw.eu Installation and Operation Instructions K35 HeatBloC with 3-temperature

More information

Installation and Commissioning Instructions High Temperature Zone Module F31-1" (DN 25)

Installation and Commissioning Instructions High Temperature Zone Module F31-1 (DN 25) PAW GmbH & Co. KG Böcklerstr. 11, D-31789 Hameln, Germany Tel.: +49-5151-9856-0, Fax: +49-5151-9856-98 Email: info@paw.eu, Web: www.paw.eu Installation and Commissioning Instructions High Temperature Zone

More information

6. Butterfly Valves & Accessories

6. Butterfly Valves & Accessories 1. Plastic Pipes 2. Steel Pipes 3. Penetration Tubes 4. Piping Accessories 5. Needle Valves 6. Butterfly Valves & Accessories 7. Miscellaneous Valves 7 1. PLASTIC PIPES TYPES OF PLASTIC PIPES ADAPTATOR

More information

V5000, V5010 Kombi-3-plus BALANCING AND SHUTOFF VALVES

V5000, V5010 Kombi-3-plus BALANCING AND SHUTOFF VALVES V5000 Kombi-3-plus RED V5000, V5010 Kombi-3-plus BALANCING AND SHUTOFF VALVES CONTENTS PRODUCT DATA Overview... 2 Design... 2 Materials... 2 Application... 2 Features... 2 Specifications... 2 Ordering

More information

RAUTITAN - water, gas & heating PRODUCT BOOK. Valid from December Construction Automotive Industry

RAUTITAN - water, gas & heating PRODUCT BOOK.  Valid from December Construction Automotive Industry RAUTITAN - water, gas & heating PRODUCT BOOK www.rehau.com Valid from December 2011 Construction Automotive Industry RAUTITAN The New Generation RELIABLE. VERSATILE. SECURE. SYSTEM OVERVIEW The RAUTITAN

More information

Buy Karcher Parts Online: Need Technical Help? Call: Requests to:

Buy Karcher Parts Online:  Need Technical Help? Call: Requests to: Page 1 of 11 Karcher Model:HD 2500 MTD ( 59588500 ) - Parts Section:1.0 PIECE PARTS 1 91825140 1 BOLT 2 91823540 2 CONTROL KNOB 3 91963040 2 SAUCER-HEAD SCREW 5 91834050 2 RUBBER BUFFER 6 91963080 2 BOLT

More information

CHARACTERISTICS ACCESSORIES. High Efficiency Pilot Operated Safety Valves

CHARACTERISTICS ACCESSORIES. High Efficiency Pilot Operated Safety Valves Technical High Efficiency Pilot Operated Safety Valves are derived from the conventional valves of the same series, and retain the same orifices. They are designed and manufactured in according to the

More information

A. This Section includes piping and related specialties for general-service compressed-air systems operating at 150 psig or less.

A. This Section includes piping and related specialties for general-service compressed-air systems operating at 150 psig or less. SECTION 221513 - COMPRESSED-AIR PIPING PART 1 - GENERAL 1.1 SUMMARY A. This Section includes piping and related specialties for general-service compressed-air systems operating at 150 psig or less. 1.2

More information

Tour b Andersson AB THERMOSTATICALLY CONTROLLED RADIATOR VALVE RVT

Tour b Andersson AB THERMOSTATICALLY CONTROLLED RADIATOR VALVE RVT Tour b Andersson AB THERMOSTATICALLY CONTROLLED RADIATOR VALVE RVT The RTV thermostatically controlled radiator valve is intended for use with 2-pipe pump-circulated hot water systems and is very effective

More information

V2000BB BB type TRV Body RADIATOR VALVE WITH BROADBAND CARTRIDGE

V2000BB BB type TRV Body RADIATOR VALVE WITH BROADBAND CARTRIDGE V2000BB BB type TRV Body RADIATOR VALVE WITH BROADBAND CARTRIDGE PRODUCT DATA Angle to EN215 (D) 011 Straight to EN215 (D) Application Thermostatic radiator valve bodies (TRV bodies) are fitted on the

More information

Integrated Valve with Presetting for Manifolds in Two-Pipe Heating Systems

Integrated Valve with Presetting for Manifolds in Two-Pipe Heating Systems Data Sheet Integrated Valve with Presetting for Manifolds in Two-Pipe Heating Systems The integrated valve is designed for manifold applications in combination with a system connection piece. Valve and

More information

T2 Wall Hung Radiator & UFH Manifolds

T2 Wall Hung Radiator & UFH Manifolds T Wall Hung Radiator & UFH Manifolds T Topway LS Pre-Assembled Heating Manifold A range of nickel plated extruded brass manifolds pre-assembled for immediate installation for both radiator and underfloor

More information

Pneumatic Circular Saw. Type Illustration can differ from the original. Spare Parts List

Pneumatic Circular Saw. Type Illustration can differ from the original. Spare Parts List Pneumatic Circular Saw Type Illustration can differ from the original Cleaning Regular cleaning is required for a continuous and proper operation. Clean the housing regularly with a soft cloth, it is important

More information

:,Rhino SD/XD G/D 24 Vdc ISO

:,Rhino SD/XD G/D 24 Vdc ISO :,Rhino SD/XDG/D Vdc ISO ()Rhino SD/XD() SD/XD Rhino SD/XDG/D Vdc ISO Rhino SD/XD, Rhino SD/Xd, (Rhino SD/XD) 006 Nordson Corporation P/N 75606A-0 Rhino SD/XDG/D Vdc ISO 0 9 5 8 7 6 P/N 75606A-0 006 Nordson

More information

RYOBI 10 in. SLIDING MITER SAW w/laser MODEL NO. TSS100L1 REPAIR SHEET

RYOBI 10 in. SLIDING MITER SAW w/laser MODEL NO. TSS100L1 REPAIR SHEET RYOBI 10 in. SLIDING MITER SAW w/laser MODEL NO. TSS100L1 REPAIR SHEET 32 96 119 31 1 85 116 86 114 92 82 117 113 112 115 97 1 6 121 1 84 59 81 87 122 128 34 174 80 66 88 114 19 79 78 115 117 116 125 126

More information