Direct solenoid and solenoid pilot operated valves

Size: px
Start display at page:

Download "Direct solenoid and solenoid pilot operated valves"

Transcription

1 Direct solenoid and solenoid pilot operated valves Individual mounting Series Inline Sub-base non plug-in 4 6 Air return Manual operator Solenoid 4-way pilot with balanced poppet Bonded spool P SERIES FEATURES Patented MACSOLENOID for fastest possible response times and virtually burn-out proof AC solenoid operation. Optional low watt DC solenoids. Various manual operators. Optional memory spring. 2 position or position valve configurations. or external pilot. 9 ISO 0 ISO 02 ISO ISO 2 ISO 9 Consult Precautions page 27 before use, installation or service of MAC Valves..

2 00% 00% WARRANTY 8 O F P R O D U C T I O N T E S T E D 00% MONTHS SPOOL CONFIGURATIONS INTERNAL PILOT EXTERNAL PILOT EXT. PILOT PORT SINGLE OPERATOR - SINGLE INLET SHOWN WITH 2 OPERATOR ENERGIZED SINGLE OPERATOR - SINGLE INLET SHOWN WITH 2 OPERATOR ENERGIZED INTERNAL PILOT (FROM # PORT) INTERNAL PILOT SINGLE OPERATOR - DUAL INLET SHOWN WITH 2 OPERATOR ENERGIZED POSITION CLOSED CENTER INTERNAL PILOT INTERNAL PILOT POSITION OPEN CENTER POSITION PRESSURE CENTER 40 Consult Precautions page 27 before use, installation or service of MAC Valves..

3 Direct solenoid and solenoid pilot operated valves Function Port size Flow (Max) Individual mounting Series /2, / /8 - /4.0 C v Inline OPERATIONAL BENEFITS. The 4-way pilot develops maximum shifting forces both ways. 2. Memory spring available.. Balanced spool, immune to variations of pressure, also provides high flow. 4. Short stroke with high flow.. Bonded spool with minimum friction, shifting in a glass-like finished bore. 6. Wiping effect eliminates sticking. 7. Long service life. HOW TO ORDER SINGLE PRESSURE MODELS Port size Pilot air /2 Single operator 4A-A0A-XX-XXXX-XXX 4A-B0A-XX-XXXX-XXX 4A-A0B-XX-XXXX-XXX 4A-B0B-XX-XXXX-XXX /2 Double operator 42A-A0A-XX-XXXX-XXX 42A-B0A-XX-XXXX-XXX 42A-A0B-XX-XXXX-XXX 42A-B0B-XX-XXXX-XXX / Closed center 2 4 4A-A0A-XX-XXXX-XXX 4A-B0A-XX-XXXX-XXX 4A-A0B-XX-XXXX-XXX 4A-B0B-XX-XXXX-XXX DUAL PRESSURE MODELS (INTERNAL PILOT PILOT PRESSURE SUPPLY FROM # PORT) Port size Pilot air /2 Single operator / Open center A-A0A-XX-XXXX-XXX 46A-B0A-XX-XXXX-XXX 46A-A0B-XX-XXXX-XXX 46A-B0B-XX-XXXX-XXX /2 Double operator / Pressure center A-A0A-XX-XXXX-XXX 47A-B0A-XX-XXXX-XXX 47A-A0B-XX-XXXX-XXX 47A-B0B-XX-XXXX-XXX P 48 SOLENOID OPERATOR 4A-A0A-XX-XXXX-XXX 4A-B0A-XX-XXXX-XXX 4A-A0B-XX-XXXX-XXX 4A-B0B-XX-XXXX-XXX DM-D XXX-XXX * XX Voltage X Wire length X Manual operator XX JA 0/0, 20/60 (2.9W) A 8 (Flying leads) Non-locking recessed KA JB 220/0, 240/60 (2.9W) B 24 (Flying leads) KD JC 24/60 (2.9W) J Connector JB FB 24 VDC (.8W) JD DA 24 VDC (.4W) DF 24 VDC (2.7W) BA SOLENOID OPERATOR GM-G XXX-XXX ** 44A-A0A-XX-XXXX-XXX 44A-B0A-XX-XXXX-XXX 44A-A0B-XX-XXXX-XXX 44A-B0B-XX-XXXX-XXX Electrical connection Square connector Square connector with light Rectangular connector Rectangular connector with light Flying leads ISO 0 ISO 02 ISO ISO 2 ISO XX Voltage X Wire length X Manual operator XX DC DD DF 24VDC (.8W) 24VDC (2.W) 24VDC (4.0W) * Other options available, see page 09. ** Other options available, see page. A 8 B 24 C 6 Non-locking recessed BA BT KA KT Electrical connection Flying leads Flying leads with light Plug-in wire assy. Plug-in wire assy. with light 4 Consult Precautions page 27 before use, installation or service of MAC Valves..

4 7 00% 00% WARRANTY 8 O F P R O D U C T I O N T E S T E D 00% MONTHS TECHNICAL DATA Fluid : Pressure range : Pilot pressure : Lubrication : Filtration : Temperature range : Flow : Coil : Voltage range : Protection : Power : Response times : Compressed air, vacuum, inert gases pilot 2 pos. : 20 to 20 PSI (with memory spring: 0 to 20 PSI) pos.: to 20 PSI pilot : vacuum to 20 PSI 2 position: 20 to 20 PSI (with memory spring: 0 to 20 PSI) position: to 20 PSI Not required, if used select a medium aniline point lubricant (between 80 F and 20 F) 40 µ 0 F to 20 F (-8 C to +0 C).0 C v Class A continuous duty, #22 AWG x 2 leads wires -% to +0% of nominal voltage Consult factory ~Inrush : 0.9 VA Holding : 7.7 VA =.8 to 2.7 W 24 V=/.4W Energize : 7. ms De-energize :. ms 20/60 Energize : 8-2 ms De-energize : 7- ms Options : Spare parts : BSPP threads Namur interface (specify mod. 080 after model) 4A-A0A-XX-XXXX-XXX Dual pressure models, replace by C for pilot supply from # port For memory spring, replace by 4 (single operator models only) Replace by 8 for position dual pressure, pressure center DM pilot body pressure seal: 642 DM pilot spacer plate: DIMENSIONS.2 DIA. MTG. HOLES, TYP.(2) 2.0 DOUBLE PILOT (DM) SIMPLE 96.0 PILOT (DM) Dimensions shown are metric (mm) PILOT W/ DM SOLENOID PILOT W/ GM SOLENOID PILOT W/ DM SOLENOID PILOT W/ GM SOLENOID 7. DOUBLE PILOT W/ PLUG-IN (GM) SINGLE PILOT W/ PLUG-IN (GM) 02. DOUBLE PILOT.0 W/ FLYING LEADS (GM) OPTIONAL MANUAL OPERATOR SINGLE PILOT W/ FLYING LEADS (GM) DIA. MTG. HOLES, TYP.(2) 60.2 PILOT W/ GM SOLENOID PILOT W/ DM SOLENOID PILOT W/ GM SOLENOID PILOT W/ DM SOLENOID PILOT W/ DM SOLENOID PILOT W/ GM SOLENOID 42 Consult Precautions page 27 before use, installation or service of MAC Valves..

5 Direct solenoid and solenoid pilot operated valves Function Port size Flow (Max) Individual mounting Series /2, / /8 - /4.0 C v Sub-base non plug-in OPERATIONAL BENEFITS. The 4-way pilot develops maximum shifting forces both ways. 2. Memory spring available.. Balanced spool, immune to variations of pressure, also provides high flow. 4. Short stroke with high flow.. Bonded spool with minimum friction, shifting in a glass-like finished bore. 6. Wiping effect eliminates sticking. 7. Long service life. HOW TO ORDER SINGLE PRESSURE MODELS Port size Valve only Pilot air /2 Single operator 4A-00A-XX-XXXX-XXX 4A-00D-XX-XXXX-XXX 4A-AAA-XX-XXXX-XXX 4A-BAA-XX-XXXX-XXX 4A-AAD-XX-XXXX-XXX 4A-BAD-XX-XXXX-XXX /2 Double operator 42A-00A-XX-XXXX-XXX 42A-00D-XX-XXXX-XXX 42A-AAA-XX-XXXX-XXX 42A-BAA-XX-XXXX-XXX 42A-AAD-XX-XXXX-XXX 42A-BAD-XX-XXXX-XXX / Closed center 2 4 4A-00A-XX-XXXX-XXX 4A-00D-XX-XXXX-XXX 4A-AAA-XX-XXXX-XXX 4A-BAA-XX-XXXX-XXX 4A-AAD-XX-XXXX-XXX 4A-BAD-XX-XXXX-XXX DUAL PRESSURE MODELS (INTERNAL PILOT PILOT PRESSURE SUPPLY FROM # PORT) Port size Pilot air /2 Single operator / Open center A-00A-XX-XXXX-XXX 46A-00D-XX-XXXX-XXX 46A-AAA-XX-XXXX-XXX 46A-BAA-XX-XXXX-XXX 46A-AAD-XX-XXXX-XXX 46A-BAD-XX-XXXX-XXX / Pressure center A-00A-XX-XXXX-XXX 47A-00D-XX-XXXX-XXX 47A-AAA-XX-XXXX-XXX 47A-BAA-XX-XXXX-XXX 47A-AAD-XX-XXXX-XXX 47A-BAD-XX-XXXX-XXX /2 Double operator P 48 Valve only SOLENOID OPERATOR 4A-00A-XX-XXXX-XXX 4A-00D-XX-XXXX-XXX 4A-AAA-XX-XXXX-XXX 4A-BAA-XX-XXXX-XXX 4A-AAD-XX-XXXX-XXX 4A-BAD-XX-XXXX-XXX DM-D XXX-XXX * XX Voltage X Wire length X Manual operator XX JA 0/0, 20/60 (2.9W) A 8 (Flying leads) Non-locking recessed KA JB 220/0, 240/60 (2.9W) B 24 (Flying leads) KD JC 24/60 (2.9W) J Connector JB FB 24 VDC (.8W) JD DA 24 VDC (.4W) DF 24 VDC (2.7W) BA SOLENOID OPERATOR GM-G XXX-XXX ** 44A-00A-XX-XXXX-XXX 44A-00D-XX-XXXX-XXX 44A-AAA-XX-XXXX-XXX 44A-BAA-XX-XXXX-XXX 44A-AAD-XX-XXXX-XXX 44A-BAD-XX-XXXX-XXX Electrical connection Square connector Square connector with light Rectangular connector Rectangular connector with light Flying leads ISO 0 ISO 02 ISO ISO 2 ISO XX Voltage X Wire length X Manual operator XX DC DD DF 24VDC (.8W) 24VDC (2.W) 24VDC (4.0W) * Other options available, see page 09. ** Other options available, see page. A 8 B 24 C 6 Non-locking recessed BA BT KA KT Electrical connection Flying leads Flying leads with light Plug-in wire assy. Plug-in wire assy. with light 4 Consult Precautions page 27 before use, installation or service of MAC Valves..

6 2 TO 20 PSI 00% 00% WARRANTY 8 O F P R O D U C T I O N T E S T E D 00% MONTHS TECHNICAL DATA Fluid : Pressure range : Pilot pressure : Lubrication : Filtration : Temperature range : Flow : Coil : Voltage range : Protection : Power : Response times : Compressed air, vacuum, inert gases pilot 2 pos. : 20 to 20 PSI (with memory spring: 0 to 20 PSI) pos.: to 20 PSI pilot : vacuum to 20 PSI 2 position: 20 to 20 PSI (with memory spring: 0 to 20 PSI) position: to 20 PSI Not required, if used select a medium aniline point lubricant (between 80 F and 20 F) 40 µ 0 F to 20 F (-8 C to +0 C).0 C v Class A continuous duty, #22 AWG x 2 leads wires -% to +0% of nominal voltage Consult factory ~Inrush : 0.9 VA Holding : 7.7 VA =.8 to 2.7 W 24 V=/.4W Energize : 7. ms De-energize :. ms 20/60 Energize : 8-2 ms De-energize : 7- ms Options : BSPP threads 4A-AAA-XX-XXXX-XXX Dual pressure models, replace by C for pilot supply from # port For flow control, replace by B For memory spring, replace by 6 Base only : 400A-XXX (i.e. 400A-AAA) Spare parts : Body to base seal: 62 Flow control assembly: N-0400 Body mounting screws (x2): 04. DIMENSIONS Dimensions shown are metric (mm) 86.2 EXTENDED OPERATOR 97.9 LOCKNING OPERATOR 8.4 C L C L STOCK REF SINGLE PILOT /8" - 27 N.P.T.F. /4" - 8 N.P.T.F. TYPICAL OPTIONAL FLOW CONTROL 2.0 DOUBLE PILOT REF. 4.0 DIA. (2) MIG. HOLES OPTIONAL EXTERNAL PILOT PORT (#0-2 UNF-28) Consult Precautions page 27 before use, installation or service of MAC Valves..

7 OPTIONS Codification table for voltages / Manual operator / Electrical connection VALVE CODE -DM- D XX X-X XX Pilot operated valves 2, 67, 92, 9, 400, ISO, ISO2, ISO Series OPTIONS AVAILABLE FOR 09 Consult Precautions page 27 before use, installation or service of MAC Valves..

8 OPTIONS. VOLTAGE D-XX X-X XX VOLTAGE DA 24 VDC (.4W) DB 2 VDC (.4W) DC 2 VDC (7.W) DD 24 VDC (7.W) DE 2 VDC (2.7W) DF 24 VDC (2.7W) DK 0 VDC (4.7W) DJ 28 VDC (.2W) DL 64 VDC (6.0W) DM 6 VDC (.W) DN 6 VDC (6.0W) DR 90 VDC (6.6W) DS 0 VDC (7.W) DT 7 VDC (.6W) DP 48 VDC (.8W) FA 2 VDC (.8W) FB 24 VDC (.8W) FE 2 VDC (2.4W) FF 24 VDC (2.4W) JA 20/60, 0/0 (2.9W) JB 240/60, 220/0 (2.9W) JC 24/60, 24/0 (.7W) JD 00/60, 00/0, 0/60 (.9W) JE 220/60 (.4W) JF 240/0 (2.8W) JG 200/60, 200/0 (.9W) 2. WIRE LENGTH D-XX X-X XX WIRE LENGTH 0 No wires A 8" B 24" C 6" D 48" E 72" F 96" 4. ELECTRICAL CONNECTION D-XX X-X XX ELECTRICAL CONNECTION BA* Flying leads (grommet) BK* BA with protection diode BL* BA with protection varistor BM** Flying leads (solenoid plug-in) BN** BM with protection diode BP** BM with protection varistor BG** BM with ground BH** BM with protection diode & ground BJ** BM with protection varistor & ground CA* /2" NPS conduit with flying leads CM* /2" NPS metal conduit with flying leads CN* /2" NPS metal conduit with flying leads & ground JB Rectangular connector JD JB with light JM Rectangular connector (male only) KA Mini square connector KB KA with protection diode KC KA with protection varistor KD KA with light KE KA with light and protection diode KF KA with light and protection varistor KG KA with light & diode KJ Mini square connector (male only) KK KJ with protection diode (male only) KL KJ with protection varistor (male only) TA Dual tabs with receptacles TB TA with protection diode TD TA with light TE TA with light and protection diode TJ Dual tabs (male only) TK TJ with protection diode TM TJ with light TN TJ with light and protection diode * From Lead wire length options choose A through F ** From Lead wire length options choose 0 through F Note: When coil is above 0 volts, a ground wire is required. Applies to options with flying leads.. MANUAL OPERATOR D-XX X-X XX MANUAL OPERATOR 0 No operator Non-locking recessed Non-locking extended 4 Locking extended 0 Consult Precautions page 27 before use, installation or service of MAC Valves..

9 OPTIONS Codification table for voltages / Manual operators / Electrical connections VALVE CODE -GM- G XX X-X XX 2 4 OPTIONS AVAILABLE FOR - Solenoid valves 2 & 400 Series Consult Precautions page 27 before use, installation or service of MAC Valves..

10 OPTIONS. VOLTAGE 4. ELECTRICAL CONNECTION G-XX X-X XX VOLTAGE DC 24 VDC (.8 W) DD 24 VDC (2. W) DE 24 VDC (.0 W) DF 24 VDC (4.0 W) DJ 2 VDC (.8 W) DK 2 VDC (2. W) DM 2 VDC (.0 W) DN 2 VDC (4.0 W) G-XX X-X XX 2. WIRE LENGTH WIRE LENGTH 0 No lead wire (use only with "KJ" & "KM" elecrical connectors) A 8" B 24" C 6" D 48" E 72" F 96" G 20" H 44". MANUAL OPERATOR G-XX X-X XX BA BB BC BD BE BF BG BH *BN *BP *BR *BS BT BU BV BW *BX *BY ELECTRICAL CONNECTION Flying leads BA with ground wire BA with light parallel to leads BA with light parallel to leads & ground wire BA with suppression diode BA with suppression diode & ground wire BA with suppression diode plus light parallel to leads BA with suppression diode plus light parallel to leads & ground wire BA with suppression diode plus blocking diode BA with suppression diode plus blocking diode & ground wire BA with suppression diode plus blocking diode & light parallel to leads BA with suppression diode plus blocking diode & light parallel to leads & ground wire BA with light on top BA with light on top & ground wire BA with suppression diode plus light on top BA with suppression diode plus light on top & ground wire BA with suppression diode plus blocking diode & light on top BA with suppression diode plus blocking diode & light on top & ground wire G-XX X-X XX MANUAL OPERATOR Non-locking recessed Non-locking extended 4 Locking extended G-XX X-X XX GA GB GC GD GE GF GG GH KA KB KE KF KJ KM *KN *KP KT KU KV KW *KX *KY SOLENOID PLUG-IN CONNECTOR WITH LEADS MAC JAC Solenoid plug-in MAC JAC Solenoid plug-in w/diode MAC JAC Solenoid plug-in w/mov MAC JAC Solenoid plug-in w/led MAC JAC Solenoid plug-in w/diode & LED MAC JAC Solenoid plug-in w/mov & LED MAC JAC Solenoid plug-in w/rectifier MAC JAC Solenoid plug-in w/rectifier & LED Plug-in wire assembly KA with ground wire KA with suppression diode KA with suppression diode & ground wire Plug-in housing without wire assembly ('KA' without wire assembly) Plug-in housing without wire assembly ('KB' without wire assembly) KA with suppression diode plus blocking diode KA with suppression diode plus blocking diode & ground wire KA with light on top KA with light on top & ground wire KA with suppression diode plus light on top Note: Blocking diode is located in the lead wire KA with suppression diode plus light & ground wire KA with suppression diode plus blocking diode & light on top KA with suppression diode plus blocking diode & light on top & ground wire 4 Consult Precautions page 27 before use, installation or service of MAC Valves..

Direct solenoid and solenoid pilot operated valves

Direct solenoid and solenoid pilot operated valves Direct solenoid and solenoid pilot operated valves Individual mounting Series Inline Manual operator Solenoid 4-way pilot with balanced poppet Inlet (1) Exhaust (3) Cylinder () 33 34 36 3 37 38 5 67 69

More information

Direct solenoid and solenoid pilot operated valves

Direct solenoid and solenoid pilot operated valves Direct solenoid and solenoid pilot operated valves Series ISO Individual mounting Valve only No base non plug-in Conform to ISO 99/ Valve only No base plug-in Conform to ISO 99/ Manifold mounting Valve

More information

Direct solenoid and solenoid pilot operated valves

Direct solenoid and solenoid pilot operated valves Direct solenoid and solenoid pilot operated valves Individual mounting Series Inline Manual operator Solenoid 4-way pilot with balanced poppet Air return 33 34 36 3 37 38 5 67 69 44 46 4 47 48P SERIES

More information

Direct solenoid and solenoid pilot operated valves

Direct solenoid and solenoid pilot operated valves Direct solenoid and solenoid pilot operated valves Manual operator Solenoid Individual mounting Sub-base non Sub-base Manifold mounting Manifold base Sub-base/ manifold base non with latching solenoid

More information

Direct solenoid and solenoid pilot operated valves

Direct solenoid and solenoid pilot operated valves Direct solenoid and solenoid pilot operated valves Individual mounting Series Inline Oval shaped armature Encapsulated coil Push pin Manifold mounting Stacking Manifold base plug-in Manifold base plug-in

More information

Direct solenoid and solenoid pilot operated valves

Direct solenoid and solenoid pilot operated valves Direct solenoid and solenoid pilot operated valves 8mm valve Series 33 Function Port size Flow (Max) Individual mounting Series 3/ NC M3 0.08 C v Inline OPERATIONAL BENEFITS 1. 8mm valve direct solenoid

More information

Direct solenoid and solenoid pilot operated valves

Direct solenoid and solenoid pilot operated valves Direct solenoid and solenoid pilot operated valves Individual mounting Series Inline Sub-base non plug-in Sub-base plug-in Manifold mounting Sub-base non plug-in Sub-base plug-in 33 34 36 32 onded spool

More information

Direct solenoid and solenoid pilot operated valves

Direct solenoid and solenoid pilot operated valves Direct solenoid and solenoid pilot operated valves SIZE 26 mm Individual mounting Valve only No base non plug-in Conform to ISO 15407/1 Manifold mounting Valve only No base non plug-in Conform to ISO 15407/1

More information

Direct solenoid and solenoid pilot operated valves

Direct solenoid and solenoid pilot operated valves Direct solenoid and solenoid pilot operated valves Individual mounting Series inline Manifold mounting 5 stacking sub-base non plug-in sub-base with pressure regulators 100 200 1 55 56 57 58 59 Manual

More information

GM - G XXX-XXX. Direct solenoid and solenoid pilot operated valves. Function Port size Flow [Max] Individual mounting. Series 77

GM - G XXX-XXX. Direct solenoid and solenoid pilot operated valves. Function Port size Flow [Max] Individual mounting. Series 77 Direct solenoid and solenoid pilot operated valves Series 77 Function Flow [Max] Individual mounting 3/2 NC, 2/2 NC 1/8-1/4 1.0 Cv Inline OPERATIONAL BENEFITS 1. The 4-way pilot develops maximum shifting

More information

Direct solenoid and solenoid pilot operated valves

Direct solenoid and solenoid pilot operated valves Direct solenoid and solenoid pilot operated valves Individual mounting Series inline inline hazardous location Manifold mounting 35 sub-base non plug-in sub-base with pressure regulators sub-base hazardous

More information

Direct solenoid and solenoid pilot operated valves

Direct solenoid and solenoid pilot operated valves Direct solenoid and solenoid pilot operated valves Individual mounting Series inline sub-base non plug-in Manifold mounting 35 stacking sub-base non plug-in sub-base with pressure regulators sub-base with

More information

Specifications 54 Series Valve

Specifications 54 Series Valve Specifications 54 Series Valve Fluids: Compressed Air or Inert Gases Lubrication: Not required. If used, select a medium aniline point lubricant (between 180ºF and 210ºF) Safe Operating Temperature Range:

More information

Direct solenoid and solenoid pilot operated valves

Direct solenoid and solenoid pilot operated valves Direct solenoid and solenoid pilot operated valves Individual mounting Series Inline Oval shaped armature Encapsulated coil Push pin onded balanced poppet Return spring Manifold mounting Stacking plug-in

More information

MAC VALVES, INC. Rev. T

MAC VALVES, INC. Rev. T REVISION LEVEL DATE RELEASED CHANGE DESCRIPTION ECN NUMBER P.E. APPROVAL P.D APPROVAL A 5-11-95 ENGINEERING RELEASE 12727 EPJ B 1-15-96 ADDED 35 SERIES 13228 EPJ ADDED MOD 2938 TO 6500 SERIES, MODS 2910

More information

Introduction Section 1 Section 2 Section 3 Section 4 Section 5 Section 6 Section 7

Introduction Section 1 Section 2 Section 3 Section 4 Section 5 Section 6 Section 7 NEW Technology Page Introduction Section 1 Section Section Section 4 Section 5 Section 6 Section 7 Direct solenoid and solenoid pilot operated valves 9 Remote air valves 197 Bases according to ISO 5599

More information

Direct solenoid and solenoid pilot operated valves

Direct solenoid and solenoid pilot operated valves Direct solenoid and solenoid pilot operated valves Individual mounting Series non plug-in plug-in Manifold mounting 35 non plug-in plug-in 100 Pilot air accumulator ir/spring return Integral ground wire

More information

MAC Pulse Valve PV03 Series

MAC Pulse Valve PV03 Series The MAC Pulse Valve series is designed to be a direct drop-in replacement for existing pulse technology. The MAC solution utilizes a long life, bonded-spool design, instead of the traditional diaphragm

More information

MAC Pulse Valve PV06 Series

MAC Pulse Valve PV06 Series The MAC Pulse Valve series is designed to be a direct drop-in replacement for existing pulse technology. The MAC solution utilizes a long life, bonded-spool design, instead of the traditional diaphragm

More information

33 SERIES 34 SERIES 34B/C - X X X - G XX X - X XX A - X X X - R XX X - X XX

33 SERIES 34 SERIES 34B/C - X X X - G XX X - X XX A - X X X - R XX X - X XX Patents and Patents Pending SMALL 3 WAY SOLENOID, AIR AND MECHANICALLY OPERATED VALVES MANUAL OPERATOR COIL SOLENOID STROKE (GAP) PUSH PIN POLE PIECE POLE PIECE SPRING The 34 series is a direct operated

More information

92 Series MAConnect with Sub D

92 Series MAConnect with Sub D 9 Series MAConnect with Sub D MAXIMUM OF 0 SOLENOIDS CAN BE POWERED BY A SINGLE MULTI-PIN CONNECTOR. UP TO 40 SOLENOIDS CAN BE POWERED BY MEANS OF A SECOND MULTI-PIN CONNECTOR STATION. LEFT OR RIGHT END

More information

External Pilot Models 5 Sgl. Sol. Plug-In to Left. Internal Pilot Models 1 Sgl. Sol. Plug-In to Left. 4 Dbl. Sol. Plug-In to Right

External Pilot Models 5 Sgl. Sol. Plug-In to Left. Internal Pilot Models 1 Sgl. Sol. Plug-In to Left. 4 Dbl. Sol. Plug-In to Right How to Order 93 Series MAConnect 93 A - X X X - X X X - XX - D XX P - X XX Pilot Valve Options (see below) Valve Function 0 Base Only A Sgl. Oper. Sgl. Press. B Dbl. Oper. Sgl. Press. C Sgl. Oper. Dual

More information

32, CONTENTS SMALL LARGE

32, CONTENTS SMALL LARGE SMALL 11,2 LARGE 3-WAY VALVES - 2 to 32 Introduction 02-03 33 Series 04 34 Series 05-06 35 Series 07-08 36 Series 09-12 37 Series 13-14 100 Series 15 200 Series 16 1100 Series 17 Introduction 18-19 52

More information

42 Series MAConnect TM. 42 Series Plug-In Manifold

42 Series MAConnect TM. 42 Series Plug-In Manifold 42 Series MAConnect TM 42 Series Plug-In Manifold Specifications 42 Series Valve Operating Data Fluids: Lubrication: Safe Operating Temperature Range: Pressure Range: Electrical: Air or Inert Gas Not Required.

More information

SITRANS F flowmeters. SITRANS F O delta p - Primary differential pressure devices. Orifice plate with annular chambers. 4/358 Siemens FI

SITRANS F flowmeters. SITRANS F O delta p - Primary differential pressure devices. Orifice plate with annular chambers. 4/358 Siemens FI Application Dimensional drawings Suitable for non-corrosive and corrosive gases, vapors and liquids; permissible operating temperature -60 to +550 C. Design Two support rings with replaceable orifice disk

More information

Bullet Valve (BV) Series

Bullet Valve (BV) Series BULLET Valve Bullet Valve (BV) Series The Bullet Valve represents yet another evolution in air valve technology from MAC. VERY FEW PARTS LONG LIFE LIFTING SOLENOID ONE PIECE POPPET / ARMATURE (Patents

More information

Bullet Valve (BV) Series

Bullet Valve (BV) Series ullet Valve (V) Series VERY FEW PARTS LONG LIFE LIFTING SOLENOID ONE PIECE POPPET / ARMATURE ALANCED DESIGN SOLENOID ISOLATED FROM CONTAMINATED AIR UNIQUE MOUNTING D-SEAL TECHNOLOGY LONG LIFE LIFTING SOLENOID

More information

82 Series MAConnect with Sub-D

82 Series MAConnect with Sub-D 82 Series MAConnect with Sub-D Maximum of 20 solenoids can be powered by a single multi-pin connector. Up to 40 solenoids can be powered by means of a second multi-pin connector station. Left or right

More information

Table 1d - FSA for All Returns, Females Tax Year

Table 1d - FSA for All Returns, Females Tax Year PR 10 Newfoundland and Labrador A0A 20,250 597,345 1,920 1,720 2,580 3,150 1,960 1,610 1,360 1,030 1,020 740 550 460 630 470 410 290 290 70 20 A0B 8,850 249,804 780 740 1,200 1,520 1,010 790 540 430 370

More information

Rodless cylinders. Standard magnetic version. High reliability and long lifetime. Low friction and good resistance to loads

Rodless cylinders. Standard magnetic version. High reliability and long lifetime. Low friction and good resistance to loads Rodless cylinders Standard magnetic version High reliability and long lifetime Low friction and good resistance to loads Installation in any position Mounting elements and switches can be ordered separately

More information

TM ETRS-TM35FIN-ETRS89 WTG

TM ETRS-TM35FIN-ETRS89 WTG Noise calculation model: ISO 9613-2 General Wind speed: 8,0 m/s Ground attenuation: General, Ground factor: 0,4 Meteorological coefficient, C0: 0,0 db Type of demand in calculation: 1: WTG noise is compared

More information

Directional Seat Valve Series D4S (Denison)

Directional Seat Valve Series D4S (Denison) Characteristics Seat valves series D4S are designed for directional control functions. A large variety of poppets, springs and covers - including shuttle valves, stroke limiters, solenoid valves (VV01)

More information

BC. Materials. Working temperature (Seals) Sectors: Industrial, Agricultural

BC. Materials. Working temperature (Seals) Sectors: Industrial, Agricultural 1 SERI ISO-A Manufactured according ISO 7241-A norm, size meets also ISO 5675 requirements. Poppet Valve or Ball closing system. BSP, NPTF, SAE/ORB threads. Others available upon request. Materials Body:

More information

SERVICE INSTRUCTION. All Certified Lycoming direct drive engines. TIME OF COMPLIANCE: At owner s discretion.

SERVICE INSTRUCTION. All Certified Lycoming direct drive engines. TIME OF COMPLIANCE: At owner s discretion. 652 Oliver Street Williamsport, PA. 17701 U.S.A. Telephone +1 (800) 258-3279 U.S. and Canada (Toll Free) Telephone +1 (570) 323-6181 (Direct) Facsimile +1 (570) 327-7101 Email Technicalsupport@lycoming.com

More information

FedEx Express Rates. Effective Sept. 15, 2008

FedEx Express Rates. Effective Sept. 15, 2008 FedEx Express Rates Effective Sept. 15, 2008 Table of Contents FedEx Express Intra-Canada Rates 2 Postal Code Index 3 FedEx First Overnight 4 FedEx Intra-Canada Index 12 FedEx Priority Overnight 14 FedEx

More information

SERVICE INSTRUCTION. 652 Oliver Street Williamsport, PA U.S.A. Tel Fax

SERVICE INSTRUCTION. 652 Oliver Street Williamsport, PA U.S.A. Tel Fax 652 Oliver Street Williamsport, PA. 17701 U.S.A. Tel. 570 323 6181 Fax. 570 327 7101 www.lycoming.com SERVICE INSTRUCTION DATE: March 8, 2012 Service Instruction No. 1098H (Supersedes Service Instruction

More information

VACUUM PRESSURE PUMPS INSTALLATION CAUTIONS AND INFORMATION READ AND FOLLOW CAREFULLY!

VACUUM PRESSURE PUMPS INSTALLATION CAUTIONS AND INFORMATION READ AND FOLLOW CAREFULLY! F.A.A.-P.M.A. MODEL 1U128A AND 1U128B REVISION 17 February 21, 2002 VACUUM PRESSURE PUMPS INSTALLATION CAUTIONS AND INFORMATION READ AND FOLLOW CAREFULLY! The following information applies to all installations

More information

Серия MAC Pulse Valve PV06

Серия MAC Pulse Valve PV06 Серия клапанов MAC Pulse Valve series разработана для прямой замены существующих решений. The MAC Pulse Valve обеспечивает использование инновационной сбалансированной шпули вместо мембраны. MAC также

More information

7. Are you upgrading a complete engine from a TCM/ Bendix to a Slick system? If yes, purchase a complete Slick Ignition Upgrade Kit.

7. Are you upgrading a complete engine from a TCM/ Bendix to a Slick system? If yes, purchase a complete Slick Ignition Upgrade Kit. 1.1 PRODUCT APPLICATION INFORMATION WORKSEET The following information will aid you in selecting the correct magneto, upgrade kit, or ignition harness: 1. Engine Manufacturer 2. Engine Model Number 3.

More information

MCC omponents Itasca Street Chatsworth

MCC omponents Itasca Street Chatsworth omponents 21201 Itasca Street Chatsworth!"# $%!"# SMBJ5.0 THRU SMBJ170CA Features For surface mount applications in order to optimize board space Low profile package Fast response time: typical less than

More information

MAC VALVES EUROPE, INC.

MAC VALVES EUROPE, INC. CURRENT Technology Page Introduction Section 1 Section 2 Section 3 Section 4 Section 5 Section 6 Direct solenoid and solenoid pilot operated valves 9 Remote air valves 165 Mechanically and manually operated

More information

General. Principles. 3-Trapped Key Switches. 11-Cat. No. Index. Logic. Power. Safety Switches Trapped Key Switches Overview

General. Principles. 3-Trapped Key Switches. 11-Cat. No. Index. Logic. Power. Safety Switches Trapped Key Switches Overview R Safety Trapped Key Overview Key Coding Below is an example reference guide that is useful in selecting and tracking codes. Start down the Aa column as the lower codes (typically Aa to Za) are stocked.

More information

EtherNet/IP EtherCAT POWERLINK PROFINET Modbus/TCP

EtherNet/IP EtherCAT POWERLINK PROFINET Modbus/TCP We are pleased to announce the release and availability of the MI/O-67 Fieldbus Platform. Our initial release includes several different protocol options in addition to several modules to ensure a complete

More information

Multiplication Tables of Various Bases

Multiplication Tables of Various Bases THE NUMBER BASE 10 100 Ternary (Base 3) 1 2 10 2 11 20 10 20 100 Quaternary (Base 4) 1 2 3 10 2 10 12 20 3 12 21 30 10 20 30 100 Quinary (Base 5) 1 2 3 4 10 2 4 11 13 20 3 11 14 22 30 4 13 22 31 40 10

More information

AUTUMN 2013 TIME SCHEDULE

AUTUMN 2013 TIME SCHEDULE AUTUMN 2013 TIME SCHEDULE Instructor 110 A LC 3 M W F 830-920 195 L EEB 105 CRAIG 11903 11904 AA QZ T 930-1020 25 L MUS 219 11905 # AB QZ T 1030-1120 25 L DEN 213 11906 AC QZ T 1230-120 25 L SMI 107 11907

More information

LYCOMING CYLINDER PRICING

LYCOMING CYLINDER PRICING SHIPPING: 2415 EMBARCADERO WAY, PALO ALTO, CA 94303 MAILING: P.O. BOX 50608, PALO ALTO, CA. 94303-0608 Phone: 650-354-1399 Fax: 650-354-1395 LYCOMING CYLINDER PRICING CYLINDER PRICING ENGINE MODEL: O-235

More information

Grade boundaries June 2018 exams. GCSE Reformed (subjects which use the 9 to 1 grade scale)

Grade boundaries June 2018 exams. GCSE Reformed (subjects which use the 9 to 1 grade scale) Version 1.0 Grade boundaries June 2018 exams GCSE Reformed (subjects which use the 9 to 1 grade scale) This document presents grade boundaries for the new reformed GCSEs which use the 9 to 1 grade scale.

More information

BULLET VALVE THINK GLOBAL ACT LOCAL. Our global distribution network is keeping your machines running around the clock around the world

BULLET VALVE THINK GLOBAL ACT LOCAL. Our global distribution network is keeping your machines running around the clock around the world THINK GLOBAL ACT LOCAL P A T E N T T E C H N O L O G Y TEL: 1-800-MAC VLVS TEL: 1 (48) 64-7700 FAX: 1 (48) 64-0549 www.macvalves.com mac@macvalves.com MAC VALVES, INC. 5555 ANN ABO OAD DUNDEE, MI 48131

More information

The Product Range. Technical Data

The Product Range. Technical Data The Product Range Section 3.1 - Basic Cylinder Bore sizes (mm): 10, 16, 25, 32, 40, 50 The basic cylinder series satisfies the support and guidance requirements of a great diversity of applications. Various

More information

DATE: May 19, 2000 Service Instruction No. 1443E (Supersedes Service Instruction No. 1443D) Engineering Aspects are FAA Approved

DATE: May 19, 2000 Service Instruction No. 1443E (Supersedes Service Instruction No. 1443D) Engineering Aspects are FAA Approved DATE: May 19, 2000 (Supersedes Service Instruction No. 1443D) Engineering Aspects are FAA Approved SUBJECT: MODELS AFFECTED: TIME OF COMPLIANCE: Approved Slick Magnetos on Textron Lycoming Engines See

More information

MCC SMBJ5.0 THRU SMBJ440CA. Features. Transient Voltage Suppressor 5.0 to 440 Volts 600 Watt. Mechanical Data

MCC SMBJ5.0 THRU SMBJ440CA.   Features. Transient Voltage Suppressor 5.0 to 440 Volts 600 Watt. Mechanical Data omponents 20736 Marilla Street Chatsworth!"# $%!"# SMBJ5.0 THRU SMBJ440CA Features For surface mount applications in order to optimize board space Low profile package Fast response time: typical less than

More information

INSTRUMENT PANEL CLUSTERS

INSTRUMENT PANEL CLUSTERS INSTRUMENT PANEL CLUSTERS NOT BUYING AT THIS TIME REVISED ##### PART # MAKE APPLICATION 6/18/2018 PRICE 56045618 CHRY IPC 40.00 56045679 CHRY IPC 40.00 56051103 CHRY IPC 40.00 56049833 AC,AD CHRY IPC 40.00

More information

CUSTOM ADD-ONS FOR ENGLISH UNITS

CUSTOM ADD-ONS FOR ENGLISH UNITS Spindles Flange Piloted Slot Collet Jacobs Taper Morse Taper See note on next page for location in the Specification Code No. Description A B C AA Flange 2.625 3.619/3.621 5.313 AB Piloted Slot 2.3125

More information

Parts List, Wiring Diagrams

Parts List, Wiring Diagrams Parts List, Wiring Diagrams PAS180-300 SERIES PACKAGE GAS ELECTRIC UNITS TABLE OF CONTENTS PARTS LIST----------- 2-16 PARTS DRAWING - - - - - 17-28 WIRING DIAGRAMS - - - 29-52 Printed in U.S.A. 5/22/08

More information

Chapter 10: Valves for Pipe Mounting

Chapter 10: Valves for Pipe Mounting Contents Chapter : Valves for Pipe Mounting Series Description Size Body Page DIN / ISO 1/8 1/4 3/8 1/2 3/4 1 1¼ 1½ 2 L-port T-port Pressure valves, manual operation R4V R4R Pressure relief function Pressure

More information

List of system parts and belonging Descriptive Documents

List of system parts and belonging Descriptive Documents DeltaV Scalable Process System includes the following system parts: Item Model Name Type Technical Data 1. KL1601X1-BA1 I/O Port (IOP) 2. KL2101X1-BA1 CHARM I/O Card (CIOC) 3. KL2102X1-BA1 Wireless I/O

More information

Distributed by: www.jameco.com 1-800-831-4242 The content and copyrights of the attached material are the property of its owner. CERAMIC CHIP CAPACITORS C0G (NP0), X7R, X5R, Z5U and Y5V Dielectrics 10,

More information

SITRANS F flowmeters. SITRANS F O delta p - Primary differential pressure devices Metering pipe with orifice plate and annular chambers 4/369

SITRANS F flowmeters. SITRANS F O delta p - Primary differential pressure devices Metering pipe with orifice plate and annular chambers 4/369 and annular chambers Application Suitable for non-corrosive and corrosive gases, vapors and liquids; permissible operating temperature -10 to +00 C. Design Orifice plate with annular chambers consisting

More information

and zero rpm. Maximum recommended pressure is 110 psi (7.6 bar). Adjustment for speed is explained under Selection Procedure.

and zero rpm. Maximum recommended pressure is 110 psi (7.6 bar). Adjustment for speed is explained under Selection Procedure. CB Construction Single Flange Dual Flange The type CB element assembly is designed and built to provide dependable clutch or brake service in the most exacting industrial applications. It is suited to

More information

SST-90 LED Binning and Labeling

SST-90 LED Binning and Labeling SST-90 LED Binning and Labeling Introduction This document describes the binning and labeling nomenclature for PhlatLight LED products as well as the orderable bin kits for each part. With each build of

More information

Type E-10, E-11 Hazardous Area Explosion-proof Transmitters

Type E-10, E-11 Hazardous Area Explosion-proof Transmitters Electronic Pressure Catalog > Hazardous Area > E-10, E-11 Type E-10, E-11 Hazardous Area Explosion-proof Transmitters Meets ANSI / ISA 12.27.01-2003 single seal requirements - no dual seal required Applications

More information

3/8 & 1/2 NPT. with 3/8 and 1/2 NPT ports for 4 Way - 2 & 3 Position see Pg locate counterbores in body to control static squeeze on seals.

3/8 & 1/2 NPT. with 3/8 and 1/2 NPT ports for 4 Way - 2 & 3 Position see Pg locate counterbores in body to control static squeeze on seals. 8 SERIES /8 Ported Air Valves 1/ Ported Air Valves /8 & 1/ 1, 1A, 1B & 8 Series Note! Spring return & spring centered models NOT suitable for dry air service. Features & Way - Position. Way - &. operator

More information

MOONEY INTERNATIONAL CORPORATION The Symbol of Performancet MOONEY SPECIAL LETTER Date:

MOONEY INTERNATIONAL CORPORATION The Symbol of Performancet MOONEY SPECIAL LETTER Date: MOONEY INTERNATIONAL CORPORATION The Symbol of Performancet MOONEY SPECIAL LETTER 15-24 Date: 11-19-2015 SUBJECT: MODELS/ S/N AFFECTED: To ADVISE MOONEY OWNERS/OPERATORS of the LYCOMING Service Instruction

More information

Airflex CB Construction Section B

Airflex CB Construction Section B Airflex CB Construction Single Flange Element Dual Flange Element The type CB element assembly is designed and built to provide dependable clutch or brake service in the most exacting industrial applications.

More information

DATE: February 13, 2019 Service Instruction No. 1037V (Supersedes Service Instruction No. 1037U) Engineering Aspects are FAA Approved

DATE: February 13, 2019 Service Instruction No. 1037V (Supersedes Service Instruction No. 1037U) Engineering Aspects are FAA Approved 652 Oliver Street Williamsport, PA. 17701 U.S.A. Telephone +1 (800) 258-3279 U.S. and Canada (Toll Free) Telephone +1 (570) 323-6181 (Direct) Facsimile +1 (570) 327-7101 Email Technicalsupport@lycoming.com

More information

VSD10M DIRECTIONAL CONTROL VALVES SOLENOID ACTUATED, PILOT OPERATED

VSD10M DIRECTIONAL CONTROL VALVES SOLENOID ACTUATED, PILOT OPERATED NFPA SIZE D10 TYPICAL PERFORMANCE SPECIFICATIONS Performance is measured on a four-way circuit (full circuit). Performance may be reduced from that shown if a three-way circuit (half circuit) is used,

More information

PRODUCT GROUP WEIGHT MIN ORDER

PRODUCT GROUP WEIGHT MIN ORDER L111280010 070115629G T5-TOUAREG OIL LEVEL DIPSTICK PLASTIC 200 20 L111300010 7H0145980D- 7H0145980F TRANSPORTER T5 TURBO S 513 1 2,5 L111300020 7H0145980E- 7H0145980C- 7H0145980G- TRANSPORTER T5- CADDY

More information

SMB5.0A(CA) - SMB440A(CA)

SMB5.0A(CA) - SMB440A(CA) SMB5.0A(CA) - SMB440A(CA) SURFACE MOUNT TRANSIENT VOLAGE SUPPESSOR DIODE VOLTAGE RANGE: 5.0-440 V POWER: 600Wa t t s Features Mechanical Data Glass Passivated Die Construction Uni- and Bi-Directional Versions

More information

SAMYANG ELECTRONICS SMBJ SMBJ440CA TRANSIENT VOLTAGE SUPPRESSOR. Features. Mechanical Characteristics

SAMYANG ELECTRONICS SMBJ SMBJ440CA TRANSIENT VOLTAGE SUPPRESSOR. Features. Mechanical Characteristics SAM YANG SAMYANG ELECTRONICS TRANSIENT VOLTAGE SUPPRESSOR BREAKDOWN VOLTAGE: 5.0 --- 440 V PEAK PULSE POWER: 600 W SMB (DO-214AA) Features Working peak reverse voltage range 5.0V to 440V. power dissipation

More information

ROTARY SHAFT / OIL SEALS GASKETS LINER RINGS REPAIR KITS BONDED SEALS O RINGS. Automotive Seals VW BARNWELL THE SEAL OF APPROVAL

ROTARY SHAFT / OIL SEALS GASKETS LINER RINGS REPAIR KITS BONDED SEALS O RINGS. Automotive Seals VW BARNWELL THE SEAL OF APPROVAL ROTARY SHAFT / OIL SEALS GASKETS LINER RINGS REPAIR KITS BONDED SEALS O RINGS Automotive Seals VW BARNWELL THE SEAL OF APPROVAL QUALITY AND SERVICE GUARANTEED Total Sealing Solutions Founded in 1972, M

More information

Chapter 6: Check Valves

Chapter 6: Check Valves Contents Chapter : Check Valves Series Description Size Mounting Page Parker Standard DIN / ISO 1/8 1/4 3/8 1/2 3/4 1 0 10 1 25 32 Subplate Screw-in Slip-in SSR RK / RB CS SPZBE SPV / SPZ C4V CPS C4V D4S

More information

ISO 5599/ Series Technical and Operating Data

ISO 5599/ Series Technical and Operating Data ISO 5599/ Series...................................................................3-9 Technical and Operating Data......................................................................3- How to Order...................................................................................5-6

More information

SPARE CONNECTORS 2008

SPARE CONNECTORS 2008 SPARE PARTS MANUAL ART.NO.: 3208201 ENGLISH INDEX SPARE CONNECTORS AA-AR SPARE CONNECTORS AS-BK SPARE CONNECTORS BL-BZ SPARE CONNECTORS CA-CP 1x 2x 3x 4x SPARE CONNECTORS CQ-DM SPARE CONNECTORS DN-EL

More information

SMA6J5.0A(CA) - SMA6J440A(CA)

SMA6J5.0A(CA) - SMA6J440A(CA) SMA6J5.0A(CA) - SMA6J440A(CA) SURFACE MOUNT TRANSIENT VOLAGE SUPPESSOR DIODE VOLTAGE RANGE: 5.0-440 V POWER: 600Wa t t s Features Glass Passivated Die Construction Uni- and Bi-Directional Versions Available

More information

Vacuum Automation 2.1. The future depends on good product choices

Vacuum Automation 2.1. The future depends on good product choices Vacuum Automation 2.1 The future depends on good product choices Combined pump and gripper 432 433 Combined pump and gripper Introduction...434 Small...436 Medium...438 Large...452 Accessories...455 434

More information

Safety 14 ga. Welded Plastic Bin Security Fire Resistant Gas Cylinder

Safety 14 ga. Welded Plastic Bin Security Fire Resistant Gas Cylinder All Cabinets Ship Flyer CAB07B...Many in 48 hrs. Heavy Duty All Welded CABINETS 40 Models Safety 14 ga. Welded Plastic Bin Security Fire Resistant Gas Cylinder Powder Coated Finish Safety Cabinets are

More information

Distributed by: www.jameco.com 1-800-831-4242 The content and copyrights of the attached material are the property of its owner. CERAMIC CHIP CAPACITORS C0G (NP0), X7R, X5R, Z5U and Y5V Dielectrics 10,

More information

CFR Series. Power Inductors OUTLINE FEATURES APPLICATIONS SPECIFICATIONS MITSUMI

CFR Series. Power Inductors OUTLINE FEATURES APPLICATIONS SPECIFICATIONS MITSUMI CFR Series Coils, Transformers OUTLINE Power inductors for preventing the diffusion of noises generated from power circuits and suppressing noise components coming through the power lines. ø8.7 ø11 max.

More information

KNOCK CYLINDERS CONTENTS ACTUATORS GENERAL CATALOG. Caution KNOCK CYLINDERS

KNOCK CYLINDERS CONTENTS ACTUATORS GENERAL CATALOG. Caution KNOCK CYLINDERS CAD drawing data catalog is available. ACTUATORS GENERAL CATALOG CONTENTS Features/Introductions of Variations 79 Double Acting Type Specifications 81 Order s 82 Inner Construction and Major Parts 83 Dimensions

More information

2/2-way and 3/2-way Normally Closed (NC) and Normally Open (NO)

2/2-way and 3/2-way Normally Closed (NC) and Normally Open (NO) Series CFB solenoid valves /-way and 3/-way Normally Closed (NC) and Normally Open (NO)»» Solenoid valves for air and water»» Great reliability over time, even in heavy working conditions The valve function

More information

Directional Control Valves. General Description. Features. Specifications

Directional Control Valves. General Description. Features. Specifications Technical Information General Description directional control valves are high-performance, 4-chamber, direct operated, wet armature, solenoid controlled, 3 or 4-way valves. They are available in 2 or 3-position

More information

REV: 000. Super Seca Flash Cure Units

REV: 000. Super Seca Flash Cure Units REV: 000 Super Seca Flash Cure Units Table Of Contents Introduction 2 Standard Operating Guide 2 Features & Specs 2 External Layout 4-15 Internal Layout 16-24 Plug Guide 25 Wiring Diagrams 26-28 F.A.Q.

More information

Series 581 ISO Pneumatic Directional Control Valves

Series 581 ISO Pneumatic Directional Control Valves Series 581 ISO 5599-1 Pneumatic Directional Control Valves Series 581 Pneumatic Valves 01_1 st Headline_36 pt/14.4 mm 4-Way ISO Directional Control second line Series 581 - A complete series of standardized

More information

SMB. Features. Mechanical Characteristics. Maximum Ta=25 unless otherwise specified. Peak Pulse Power Dissipation by10/1000μs Test Waveform

SMB. Features. Mechanical Characteristics. Maximum Ta=25 unless otherwise specified. Peak Pulse Power Dissipation by10/1000μs Test Waveform KLS5-SMBJ Features SMBJ Series *600W peak pulse capability at 0/000μs waveform *IEC 6000-4-2(ESD) 5Kv(air), 8kV(contact) *Quick response to surge voltage *Excellent clamping capability *Typical failure

More information

Heavy Duty Actuators CONTROLS. Pneumatic Actuators for Quarter-Turn Valves and Dampers Torques to 1,600,000 in. lbs. Double Acting and Spring Return

Heavy Duty Actuators CONTROLS. Pneumatic Actuators for Quarter-Turn Valves and Dampers Torques to 1,600,000 in. lbs. Double Acting and Spring Return CONTROLS Division of A-T Controls Heavy Duty Actuators Pneumatic Actuators for Quarter-Turn Valves and Dampers Torques to,600,000 in. lbs. Double Acting and Spring Return THD S E R I E S The Triac line

More information

Microbore Hose, Assemblies & accessories

Microbore Hose, Assemblies & accessories bar DN2 and DN4 High pressure Microbore hose Technical data Microbore hose The microbore hose assembly, most commonly used to connect to a Minimess test point for pressure testing, has many other diverse

More information

Sierra Differential

Sierra Differential http://www.super7thheaven.co.uk/sierra_rear_differential Sierra Differential Despite its age, the Ford Sierra Diff still dominates as the No. 1 choice of diff for kit car builders. It's been well documented

More information

Constricting Type Clutches and Brakes

Constricting Type Clutches and Brakes Constricting Type Clutches and Brakes B Constricting Features B-1 Element Descriptions B-3 CB Elements B-5 Technical and Dimensional Data B-9 Clutch and Brake Applications B-15 Mounting Components B-40

More information

AENOR Product Certificate

AENOR Product Certificate registered office AENOR certifies that the organization ADEQUA WS, S.L.U. PO DE RECOLETOS, 3-28004 (Madrid - Spain) supplies Unplasticized poly (vinyl chloride) (PVC-U) fittings for soil and waste discharge

More information

Contact Air Incorporated for further assistance. Ph:

Contact Air Incorporated for further assistance. Ph: Form DVA-10 Rev. 7/10 DASH 1... 1-11 Cutaway Drawing... 2 Color Coding... 1,2,6 Mounting Styles... 3 Electrical Connector Options... 4 Temperature Range... 5 Electrical Specifications... 5 Part Number

More information

Field Variable Area Flowmeters BFP Global Purgemaster

Field Variable Area Flowmeters BFP Global Purgemaster Data Sheet IT Field Variable Area Flowmeters BFP Global Purgemaster 10A6100 n High Strength Stainless Steel Body - Rigid construction to maintain tube alignment and resistance to pipe strain. n "Snap-in"

More information

Installation, Maintenance & Parts Manual

Installation, Maintenance & Parts Manual Installation, Maintenance & Parts Manual Flat Belt Center Drive LPZ Conveyors Table of Contents Warnings General Safety........................... 2 Introduction.......................................

More information

Stars or starlets? Competitor overview switching devices. Only for internal use. sirius IN COMPARISON

Stars or starlets? Competitor overview switching devices. Only for internal use. sirius IN COMPARISON Only for internal use Stars or starlets? Competitor overview switching devices sirius IN COMPARISON Who are the real stars? The comparison. Under ideal conditions, the human eye can make-out approximately

More information

Genuine Metaris Gear Product Technical Catalog. Pumps & Components - MH Series Bearing & Bushing Style

Genuine Metaris Gear Product Technical Catalog. Pumps & Components - MH Series Bearing & Bushing Style Genuine Metaris Gear Product Technical Catalog Pumps & Components - MH Series Bearing & Bushing Style www.metaris.com MH365 Series Bushing Pump Features Metaris Bushing Pumps & Motors are available in

More information

There are many pre-designs of Vulkan launcher.

There are many pre-designs of Vulkan launcher. There are many pre-designs of Vulkan launcher. This is next one: age A(x8) - h=45 m, d=3,9 m age B - h=57 m, d=7,75 m age C - h=27 m, d=6,7 m escape syem - h=3,8 m, d=1,1 m Model 2 H ~920 mm Paper used:

More information

CAT. No. KS-570E. SCS Single Action Push Type. SCD Double Action Type. super. cylinder FUJIKURA RUBBER LTD.

CAT. No. KS-570E. SCS Single Action Push Type. SCD Double Action Type. super. cylinder FUJIKURA RUBBER LTD. CAT. No. KS-570E SC SCS Single Action Push Type SCD Double Action Type super cylinder FUJIKURA RUBBER LTD. General Description of BF Cylinders FC Series : Single/Double Action Standard Cylinders SC Series

More information

3/8 & 1/2 NPT. 4-Way - 5 Ported - 2 Position - Type 2 Use on all 4 Way - 2 Position applications

3/8 & 1/2 NPT. 4-Way - 5 Ported - 2 Position - Type 2 Use on all 4 Way - 2 Position applications 8 SERIES: /8 Ported Air Valves, A & B SERIES: / Ported Air Valves /8 & /, A, B & 8 Series, & Way; & Position Operation to 50 psi Note! Spring return & spring centered models NOT suitable for dry air service.

More information

IEC CONTACTORS. Contacts Model List Model List AC3 UL 115 V 230 V 200 V 230 V 460 V 575 V NO NC Number Price Number Price 3RT101

IEC CONTACTORS. Contacts Model List Model List AC3 UL 115 V 230 V 200 V 230 V 460 V 575 V NO NC Number Price Number Price 3RT101 IEC CONTACTORS Description: RT01 Contactors Are Available With Cage Clamps On The Main Terminal Connections As Well As The Auxiliary Terminal Connections. RT02, RT0 and RT04 Contactors Are Available With

More information

International standard flanges acc.to SAE, ISO, DIN, GOST. [bar] 0,5 (7.3 PSI)

International standard flanges acc.to SAE, ISO, DIN, GOST. [bar] 0,5 (7.3 PSI) Gear Pump High Performance Version GP3 up to cm 3 (6. inch 3 ) p max 32 bar (46 PSI) Speed from 35 to 32 RPM Technical Features Operating pressure 29 bar, Peak pressure 32 bar High-strength quality aluminum

More information

Flow Measurement SITRANS F O delta p - Primary differential pressure devices

Flow Measurement SITRANS F O delta p - Primary differential pressure devices Technical description Primary differential pressure devices to DIN EN ISO 5167 Nominal diameters EN: DN 50... DN 1000 ASME: 2 inch 40 inch Nominal pressure EN:... 0 ASME: 600 Orifice plates with annular

More information