Flowsensor for compressed air

Size: px
Start display at page:

Download "Flowsensor for compressed air"

Transcription

1 TOTAL OUT1 ERROR Nkm 3 Nm3 N Nm 3/min Flowsensor for compressed air Ideal for plant energy-saving control This sensor is ideal for controlling and checking the flow of compressed air at plants and equipment lines, etc. Flow rate sensor - FLUEREX PF500D to PF16000E Series. Sensor section IP64 drip-proof-compatible This sensor can be installed in position. A straight piping section is not needed when installing the flow meter (excluding the PF16000E). Monitor Easy-to-read digital display Display functions are switched with one-touch key operations. PF500D PF1000D PF2000D PF4000D PF8000D PF16000E PFK500D PFK1000D PFK2000D PFK4000D PFK8000D The separated type enables operation at random sites. Covering a wide range of flow rates with 11 models Major applications Flow rate control at plants Flow rate control in manufacturing lines or devices Energy-saving measures at plants Model series system Port size Flow rate range NL/min FLUEREX Tester kit 10A 15A 25A 40A 50A ,000 10, , Optimum for ISO14001 acquisition Monitor functions Instantaneous flow display (Standard) Cumulative flow display (Standard) Peak flow display (Standard) Flow load display (Standard) Pressure range 1.5 P Output function ISO14001 Large flow rate types compatible with controlling energy saving in the each plant are available. This component is indispensable for acquiring International Standard Organization ISO14001 certification for your environment management system. This sensor also functions as a flow sensor for different devices. Eliminate compensation - read directly with a digital gauge Bothersome pressure compensation and temperature correction are not required. The digitally displayed value can be directly read in. Pressure compensation not necessary: detection of mass flow Temperature correction not necessary: Automatic temperature correction function integrated High practical precision at ±3%F.S. A practical precision of ±3%F.S. is realized without correction at temperatures from 0 to 40 C and pressures from to 1.5. Practical precision expresses linearity, pressure, and temperature with a composite error based on JIS Standards JISZ8103. Easily estimate working air capacity The standard estimate function makes it easy to measure working air capacity. Variety of output functions Four analog output types and a pulse output type ideal for networking, are available in addition to switch output. Portable kit Five types of tester kits (PFK) containing a sensor, monitor, and piping, etc., in a trunk are available. This kit is used for different applications. Quick wiring and piping connections are used. 40 Temperature range 0 AIR FLOW MONITOR FLUEREX CHANGE PF SERIES Switch output (Standard) Analog output 0 to 5 VDC (Standard) 4 to 20 madc (Option) 1 to 5 VDC (Option) 0 to 10 VDC (Option) Pulse output (option) Perfect for networks connecting personal computers, etc. Refrigerating Desiccant High polymer membrane dryer Air filter Automatic drain other F.L (Module) F.L (Separate) Small F. Precise Electro pneumatic Auxiliary Flow control valve Silencer Check valve / others Joint / tube F. generator auxiliary / pad Mechanical pressure pressure dif. pres. Seating / close contact conf. Pressure for coolant for air Total air system Water cooling refrigerator for water For compressed air Note: Only the port sizes indicated with are available for the tester kit

2 PF Series Applications For flow rate control in paint lines For flow rate control in automobile manufacturing lines For flow rate control per line! Cost conversion by integrating flow rate display For semiconductor manufacturing equipment For flow rate control of expensive air with low dew point! Ready detection of trouble such as "overflow", etc.! For flow rate control of loom plant For low pressure casting devices For control of die cooling temperature! Ejection cylinder Die Compressed air Molten metal Stoke Crucible 1006

3 Compressor air flow sensor PF and PFK Series DANGER Working fluid 1 Do not use this product for flammable fluids. Work environment 1 Explosion-proof environment Do not use this product in an atmosphere containing flammable gas. It does not have an explosion-proof structure, so flame or fires could occur. WARNING Working fluid 1 This product is not to be used as a business meter. This product does not conform to Measuring Laws, and thus cannot be used for commercial purposes. Use this sensor for industrial applications. 2 Compressed air or nitrogen can be used. Do not use other fluids or the precision cannot be guaranteed. 3 Compressed air from the compressor contains drainage water, oil oxide, foreign substances, etc. so install a filter, air dryer, and oil mist filter on the primary side (upper stream side) of the sensor. The sensor's meshing rectifies flow in the pipe. It does not filter out foreign substances, so provide a filter. Filter Air dryer Oil mist filter Valve CAUTION 1 Sensor and monitor combination With the conventional PF4000/8000, the sensor and monitor were used as a non interchangeable pair. The PF500D, 1000D, 2000D, 4000D, 8000D, and 16000D Series have independent sensors and monitors. Sections within the same model series can be interchanged. (1) PF4000/8000 <Example> PF4000 monitor A PF4000 monitor A Pneumatic components (Sensor devices) Safety Precautions Read this before starting use. Please refer to Intro 43 for general details on the pneumatic components, and to " Precautions" in this section for detailed cautions pertaining to each series. PF4000 sensor A PF4000 sensor B Only sensor A can be connected to monitor A. Sensor B cannot. Design & Selection 2 Applicable fluids There is a risk of oxygen deficiency if nitrogen gas is used for the applicable fluid. Observe the following points when handling: (1) Use this product in a well-ventilated place. (2) Ventilate the area while using nitrogen gas. (3) Regularly check nitrogen gas piping for leaks. Design & Selection Working environment 1 Corrosive environment Do not use this product in an environment containing corrosive gases such as sulphur dioxide. 2 Fluid temperature Keep the fluid temperature within 0 to 40 C. Do not use this product where temperature suddenly changes, even if ambient temperature is within specifications. Otherwise, dew could form. 3 Maximum working pressure and specified flow rate range Applications exceeding the maximum working pressure and specified flow rate range may result in faults. Use this product only within the specified range. 4 Drip-proof environment. Only the sensor conforms to IP64. The sensor is dust-proof and drip-proof, so problems do not occur if water gets on the sensor during maintenance or cleaning. The sensor should not be exposed to water for long periods or used in places where water and oil scatter with force. Design & Selection (2) PF500D/1000D/2000D/4000D/8000D/16000E <Example> PF500D monitor A PF500D sensor A PF500D monitor A PF500D monitor A PF1000D monitor PF4000 monitor Sensors A, B, and C can be freely interchanged and connected with monitor A if sensors are from the same model. Differing models cannot be interchanged. Old and new models cannot be interchanged. 2 Use within an ambient temperature range 0 to 50 C. 3 Avoid using in areas where vibration exceeds 49m/s 2 and impact 294m/s 2. Vibration of 49 m/s 2 and over PF500D sensor B PF500D sensor C PF500D sensor PF4000D sensor Safety Impact of 294 m/s 2 and over Desiccant High polymer membrane dryer 1007 Refrigerating Air filter Automatic drain other F.L (Module) F.L (Separate) Small F. Precise Electro pneumatic Auxiliary Flow control valve Silencer Check valve / others Joint / tube F. generator auxiliary / pad Mechanical pressure pressure dif. pres. Seating / close contact conf. Pressure for coolant for air Total air system Water cooling refrigerator for water For compressed air

4 Pneumatic components (Sensor devices) Safety Precautions Read this before starting use. Please refer to Intro 43 for general details on the pneumatic components, and to " Precautions" in this section for detailed cautions pertaining to each series. Safety Compressor air flow sensor PF and PFK Series DANGER Installation, Piping & Wiring 1 Set the power voltage and output at the specified voltage. Application of voltage exceeding the specified voltage could result in malfunctions, sensor damage, electrical shock, or fire. Do no use a load exceeding the output rating. Failure to observe this could result in output damage or fire. Wiring WARNING 1 Check the wire color and terminal numbers when wiring. Incorrect wiring connections could result in sensor damage, problems, and malfunctions, so check wire color and terminal numbers against the instruction manual before wiring. Use a wire with the same or higher performance than the 600 V vinyl wire for the power supply and other wiring. Insert a noise filter if required. 2 Ground the FG terminal with Class 3 grounding (100Ω or less). Do not use a common ground with the power distribution system. Installation, Piping & Wiring 3 Check wiring insulation. Check that wires do not contact other circuits and that there are no ground faults or insulation faults across terminals. Overcurrent could flow in and damage the sensor. 4 Separate the monitor from high-voltage wires, high voltage devices, and powered devices such as motors. 5 Check that there are no swarf or wire scraps on the monitor's gland and sensor connectors before wiring. CAUTION Installation, Piping & Wiring Piping 1 This sensor can be installed vertically, horizontally, or in any other position. 2 When adjusting the flow with a metering valve (globe valve, ball valve, etc.), install the metering valve on the secondary side of the sensor (downstream). If the metering valve is installed on the primary side, drift (turbulent flow) could occur and result in an error. 4 Do not install a regulator before the sensor (on the primary side). 5 When using an elbow or bushing (up to 1 port size rank difference) in piping for the PF16000E Series, install a 10D or larger straight pipe on the upstream side and a 5D or larger straight piping section on the downstream side. If there is no straight piping section, drift (turbulent flow) could occur and result in an error. * "D" here refers to the piping material bore. Metering valve Metering valve 3 When installing a stop valve on the primary side of the sensor for maintenance, use the stop valve fully open or fully closed. 10 D 5 D Using an elbow 10 D 5 D Using a bushing 1008

5 Refrigerating Desiccant High polymer membrane dryer Air filter CAUTION Installation, Piping & Wiring 6 When installing the sensor on piping, use the following torque so that excessive screw-in torque or load torque is not applied to the connection port: Model No. PFS500D PFS1000D PFS2000D PFS4000D PFS8000D PFS16000E A. max. screw torque N m B. max. load torque N m Resin cover Load torque Screw torque 7 Align the fluid direction and the direction shown on the body when piping. The indicated flow rate increases if connected in reverse. Flow direction 8 Clean out piping to remove foreign substances and swarf, etc., before piping. The rectifying unit or platinum sensor could be damaged if a large amount of foreign substances or swarf, etc., enters. 9 Check that force is not applied to resin parts when piping. 10 Check that sealing tape or adhesive does not get inside when piping. When winding fluorine resin sealing tape around threads, wind sealing tape 1 to 2 times, leaving 2 to 3 threads open at the end of the screw. Press down on tape to stick it to threads. When using liquid sealing agent, leave 1 to 2 threads open from the end, and avoid applying too much. Check that the sealing agent does not get on the device's threads. Sealing tape Solid/liquid sealing agent Solid/ Solid/ liquid liquid sealing sealing agent agent Acceptable Not acceptable Acceptable Not acceptable Wiring 1 Separate the cable from sources of noise such as power distribution wires. Failure to do so could result in malfunctions caused by noise. 2 Use the enclosed cable PF-FL (3 m) to wire the sensor to the monitor. Use the CKD extension cable PF-FL (length 3 m) to extend the cable. The enclosed cable can be connected to the extension cable for a maximum of 6 m. Contact CKD if longer distances are required. The extension cable is compatible with all models dia. 6.7 dia Do not short-circuit the output contact. 4 Do not use this product for loads generating surge voltage. When directly driving a load that generates a surge, such as a relay or solenoid valve, use a sensor with integrated surge absorbing element. Similarly, use surge countermeasures if there is a source of surge in the power supply line. (Refer to "Protection circuit for monitor contact" on the following page.) 5 Do not repeatedly bend or tension to leads or wires could disconnect. Automatic drain other F.L (Module) F.L (Separate) Small F. Precise Electro pneumatic Auxiliary Flow control valve Silencer Check valve / others Joint / tube F. generator auxiliary / pad Mechanical pressure pressure dif. pres. Seating / close contact conf. Pressure for coolant for air Total air system Water cooling refrigerator for water For compressed air 1009

6 Pneumatic components (Sensor devices) Safety Precautions Read this before starting use. Please refer to Intro 43 for general details on the pneumatic components, and to " Precautions" in this section for detailed cautions pertaining to each series. Safety Compressor air flow sensor PF and PFK Series WARNING During use & Maintenance 1 A flow several times higher than the rated flow occurs if the valve connected to the sensor is suddenly opened. This can damage the platinum membrane sensor or rectifying unit and cause fluid to flow to the secondary side. Gradually open the valve connected to the sensor while checking that the monitor display does not exceed the rated flow. CAUTION During use & Maintenance 1 If an error occurs during operation, immediately turn power OFF, stop use, and contact your dealer. Slight heating (40 C) of the display section is not a problem. 2 Internal settings, such as the hardware check, are made in the first 10 seconds after power is turned ON. The display and output do not function correctly during this time. If an interlock circuit is established with control system devices using switch output, an abnormal stop could occur, so mask the output during this time. 3 When the output setting is changed, the control system devices could operate unintentionally. Stop devices before changing settings. 4 Inspect the sensor at least once a year and confirm that it is operates correctly. 5 Do not disassemble or modify the sensor or problems could result. 1010

7 Contact protection circuit for monitor The monitor has an integrated switch contact. Provide the following protection circuit to protect the contact from inductive loads: CR Diode Diode and Zener diode Variable resistor Power supply Application Circuit example Features and other items Selecting the element AC DC Monitor (OUT1) C Load Monitor (OUT1) C Power supply Monitor (OUT1) Power supply Monitor (OUT1) Power supply Monitor (OUT1) Power supply Monitor (OUT1) Power supply Inductive load Inductive load Inductive load Inductive load Inductive load Avoid using the following arc suppressors: R C R * These are extremely effective for extinguishing arcs at cut off, but capacity is accumulated in C when the contact is opened. C's shortcircuit current flows when the contact is tripped and causes the contact to melt easily. * When using with an AC voltage, check that load impedance is sufficiently smaller than CR impedance. When the load is a relay or solenoid, recovery time is delayed. Connect the circuit between loads when using a 24 or 48 V power voltage and across contacts for a 100 to 200 V power voltage for maximum effect. Energy accumulated in coils is passed as current by the parallel diode, and consumed as Joule heating by inductive load resistance. Recovery for this takes even longer than for C This is effective when recovery of the diode is too slow. This uses the constant voltage of the variable resistor to prevent very high voltage from being applied across contacts. Recovery is also slower with this method. Connect the circuit between loads when using a 24 to 48 V power voltage and across contacts for a 100 to 200 V power voltage for maximum effect. Power supply Monitor (OUT1) C Load PF/PFK Series Contact protection circuit for monitor The guide for C and R is: C: 1 to 0.5 (uf) of the contact current 1 A R: 0.5 to 1 (W) of the contact voltage 1 V. These may not necessarily match due to dispersion in load characteristics, etc. Test the state while considering that C is affected by discharge suppression when the contact is opened, and R plays a role in suppressing current when power is turned ON next. Generally, C should have a withstand voltage between 200 and 300 V. When an AC circuit is involved, use an AC capacitor (no polarity). Use a diode with a reverse withstand voltage that is 10-fold or more than circuit voltage and for which forward current is larger than load current. If circuit voltage is not that high for the electronic circuit, a diode with a reverse withstand voltage 2 to 3 times larger than the power voltage can be used. The Zener voltage of the Zener diode is approximately the same as the power voltage. Select cut voltage Vc to satisfy the following condition: When using alternating current, voltage must be multiplied by 2. Maximum contact voltage > Vc > Power voltage This is extremely effective for extinguishing arcs at cutoff, but charged current flows to C when the contact is tripped, causing the contact to melt easily. It is usually more difficult to switch a DC induction load than to a resistance load, so performance can be increased to the same level as the resistance load by using an appropriate arc suppressor. Keep wiring short to prevent effects from noise. Separate wire from sources of noise such as power distribution cables. Refrigerating Desiccant High polymer membrane dryer Air filter Automatic drain other F.L (Module) F.L (Separate) Small F. Precise Electro pneumatic Auxiliary Flow control valve Silencer Check valve / others Joint / tube F. generator auxiliary / pad Mechanical pressure pressure dif. pres. Seating / close contact conf. Pressure for coolant for air Total air system Water cooling refrigerator for water For compressed air 1011

8 PF/PFK Series PF and PFK Series electrical wiring 1 Switch output The monitor has 1 independent contact. Observe the following precautions when using this contact: Contact specifications Load Descriptions RatedLoad Rated energizing current Maximum contact voltage Maximum contact current Maximum contact capacitance Resistance load (COS φ = 1) Inductive load (COS φ = 0.4, L/R = 7ms) AC110V 0.5A AC110V 0.2A DC24V 1A DC24V 0.3A 2A AC125V, DC60V 1A 60VA, 30W 30VA, 15W Integrated relay: G2Q-187P-V, OMRON 2 Analog output (Option symbol: No symbol, -A1, -A2, -A3) Analog output (V) Analog output (V) Analog output (ma) Analog output (V) If the ratings at left are exceeded, use an auxiliary relay to turn the load ON and OFF. When using an inductive load, such as an auxiliary relay, on the relay contact's output, use a CR filter as the arc suppressor circuit (when using AC), or protect the circuit with a diode, etc. (Refer to the Contact protection circuit for monitor section on page 1011.) Load resistance for analog output Descriptions Analog output DC0 to 5V DC4 to 20mA DC1 to 5V DC0 to 10V PF500D PFK500D PF1000D PFK1000D PF2000D PFK2000D PF4000D PFK4000D PF8000D PFK8000D PF16000E Load resistance 1MΩ or more 500Ω or less 1MΩ or more 1MΩ or more Model no. Min. value (N /min) FS(N /min) The relation of the flow and analog output is shown in the graphs at left. Analog output is not output correctly when lower than the minimum. Note that flow is displayed on the monitor even when less than the minimum. Do not short-circuit the analog output terminal (AO) with other terminals. Failure to observe this could result in problems. Keep wiring short to prevent the effect of noise. Separate the wire from sources of noise such as power distribution cables. 3 Cumulative pulse output (Option symbol: -A6) The cumulative pulse outputs the pulse at the following cumulative value: [N ] Model No. PF500D PF1000D PF2000D PF4000D PF8000D PF16000E Cumulative flow rate per pulse Example: The pulse waveform for the PF8000D is shown below. When the cumulative display exceeds When the cumulative display exceeds 100N 200N 40msec 40msec 40msec Electrical specifications Output circuit Transistor output Internal circuit OUT21 Rating across OUT21 and 22 Maximum rated voltage: 35 VDC Maximum rated current: 50 ma ON ON 40 msec Common GND OUT22 OFF OFF Time Time 1022 Note that the cumulative display is updated at 1 s intervals.

9 4 Wiring the sensor and monitor Observe the following precautions when wiring Gland layout PF/PFK Series Electric wiring Use the CKD dedicating connector cable (PF-FL ). Specifications : For DC applications 4-core 0.5 mm 2 Equivalent : X2S2F-D421-G80-A, OMRON Note that the cable is 5 m long. Use the CKD extension cable (PF-FL ) to extend the cable. The dedicating cable can be connected with the extension cable to achieve a maximum length of 6 m. Extending the cable any longer results in errors. Cumulative flow is cleared by connecting the RES terminal to the GND terminal. Refrigerating Desiccant High polymer membrane dryer Air filter Automatic drain other F.L (Module) F.L (Separate) Small F. Precise Electro pneumatic Auxiliary Flow control valve Silencer Check valve / others Joint / tube F. Pulse output (Option symbol: -A6) generator auxiliary / pad Mechanical pressure pressure dif. pres. Seating / close contact conf. Pressure for coolant for air PFK500D to 8000D Total air system Coupler storage section Cable and power cord storage section Switch output terminal Recorder terminal Cable (3m) Water cooling refrigerator for water For compressed air Power cord (2. 5m) Power switch AC100V 1023

10 PF/PFK Series Explanation of monitor functions and operations Bar graph Sensor error light Shows the peak value and load factor. Indicates errors in the sensor section. The sensor's power is shut off when this light is ON. 5-digit digital display <MEASUREMENT MODE> Displays the instantaneous and Switch output light cumulative flows. <WRITE MODE> < MODE> Indicates the switch's output state. Displays the switch setting, bar graph setting, peak value, etc. Unit display light Read key Indicates the unit for the "5-digit digital Reads the setting value. display". Shifts to the < MODE>. CHANGE key <MEASUREMENT MODE> Toggles between instantaneous and Shift key UP key cumulate flows. <WRITE MODE> <WRITE MODE> Shifts the blinking digit to the right. <WRITE MODE> Increments the blinking digit. Changes the setting. * The unit of instantaneous flow displayed for the PF16000E is Nm 3 /min. <MEASUREMENT MODE> The normal flow is measured and displayed. Switch operation : Operating state Analog output : Operating state Flow display changeover Instantaneous flow <Unit> N N N N Cumulative flow <Unit> N N N N Cumulative flow <Unit> N N N N Cumulative flow <Unit> N N N N N N N N PF/PFK Series Explanation of functions and operation Changing the flow temporarily Use this to show cumulative flow rate for a short time, while show the instantaneous flow normally. 1) The display shown at left is displayed when the CHANGE key is pressed. Note that only the unit matching the current cumulative flow is displayed when this display is opened first. 2) The unit light blinks when the temporary value is displayed. 3) The original display is returned to after 10 seconds. Changing the normally displayed flow Use this to select the flow to be displayed at all times. 1) Press the CHANGE key. When the required display is displayed, hold down the CHANGE key for 5 seconds. 2) The changeover is completed when the unit light changes from blinking to continuously lit. 3) The instantaneous flow is displayed at shipment. Refrigerating Desiccant High polymer membrane dryer Air filter Automatic drain other F.L (Module) F.L (Separate) Small F. Precise Electro pneumatic Auxiliary Flow control valve Switch parameters Three types of parameters are selected based on the application. < MODE> Hold down the and keys simultaneously for 3 seconds. The switch setting, bar graph setting, etc., are read out. CHANGE Peak display Switch operation : Operating state Analog output : Operating state Switch parameter display Switch Low display Switch High display Hysteresis display Bar graph 100% display Cumulative value display Hold down the and keys simultaneously for 3 seconds. Hold down the and keys simultaneously for 10 seconds. <WRITE MODE> The switch setting, bar graph setting value, etc., are set or changed. Switch operation: Stopped Analog output: Operating state Switch parameter setting Switch Low setting Switch High setting Hysteresis setting Bar graph 100% setting Peak value cleared Cumulative value cleared Set the required value by pressing the (SHIFT key) and (UP key) at the (Up Key) blinking digit (Shift Key) CHANGE CHANGE CHANGE CHANGE CHANGE Hysteresis A wide setting can be made randomly. Hysteresis Flow (Hysteresis is set with parameters 0 and 1.) Hysteresis Bar graph 100% setting The load factor is displayed on the bar graph when the 100% flow rate is set. Displaying and clearing the peak value The peak value within 24 hours after power ON or after the peak value was cleared is displayed. To clear the value, hold down the and keys simultaneously for 10 seconds, then change to MEASUREMENT MODE. Data is cleared. Displaying and clearing the cumulative value The cumulative flow from the value at shipment is displayed. To clear the value, hold down the and keys simultaneously for 10 seconds, then change to MEASUREMENT MODE. Data is cleared. Silencer Check valve / others Joint / tube F. generator auxiliary / pad Mechanical pressure pressure dif. pres. Seating / close contact conf. Pressure for coolant for air Total air system Water cooling refrigerator for water For compressed air

11 PF/PFK Series Explanation of functions Piping adapter Fluid direction Pressure loss characteristics Rectifier Platinum membrane sensor (fluid temperature detection resistor) Platinum membrane sensor (heater temperature detection resistor) Flow path The sensor section consists of a rectifier that passes an even amount of compressed air, a heater temperature detection resistor with integrated heater, and fluid temperature detection resistance for detecting fluid temperature. When compressed air is not flowing, electricity flows to the heater at the heater temperature detection resistor to maintain it at a set temperature. When compressed air flows, heat is lost in proportion to the air mass, so current flows to the heater temperature detection resistor to maintain the set temperature. The monitor receives a signal indicating the amount of electricity that has flowed, and displays the air's instantaneous and cumulative flows obtained by converting to 0 C with practical atmospheric pressure. The fluid temperature detection resistor measures and compensates for the temperature of compressed air PF500D / PF1000D PF1000D-15 / PFK500D / PFK1000D PF2000D-10 Pressure loss () Pressure loss () Flow (N /min) PF2000D-15 / PFK2000D PF8000D Flow (N /min) Pressure loss () Pressure loss () PF4000D Flow (N /min) Flow (N /min) PF8000D-40 / PFK8000D Pressure loss () Pressure loss () Flow (N /min) PF4000D-25 / PFK4000D Flow (N /min) PF16000E-50 Pressure loss () Pressure loss () Flow (N /min) Flow (N /min) Flow (N /min) Pressure loss ()

12 for compressed air (flow rate sensor) PF500D to PF8000D / PF16000E Series for compressed air with various functions Flow rate range: 25 to 500, 50 to 1000, 100 to to 4000, 400 to 8000 and 800 to 16000N /min CAD DATA AVAILABLE. Specifications Descriptions Spec. Working conditions Accuracy Output Installation Diversion range Port size Applicable fluid Working air quality N /min Max. working pressure Min. working pressure Withstanding pressure Ambient temperature and humidity Fluid temperature C Linearity Pressure characteristics Temperature characteristics Output response time sec Display Min. display flow rate * 3 Integrating flow rate Analog output Switch output Pulse output (option) * 4 Power supply Cable Set value holding function Installation attitude Installation strait piping section Protective structure Mass kg PF500D -10 PF500D -15 PF1000D -10 PF1000D -15 PF2000D to to to to to to Rc3/8 Rc1/2 Rc3/8 Rc1/2 Rc3/8 Rc1/2 Rc1/2 Rc1 Rc1 Rc1 1 /2 Rc2 Compressed air / N2 gas Atmospheric dew point -17 C or less (* 1) to 50 C, 85%RH or less 0 to 40 ± 1.5%F.S (0.7, 20 C) ± 2.5%F.S. * 2 ± 1.5%F.S ( to 1.5, 0.7 standard) ± 2.0%F.S (0 to 40 C, while 20 C standard) Approx Approx N /pulse PF2000D digits LED display 10N /min 20N /min 30N /min 50N /min 100N /min 0.2Nm 3 /min Max. 9 digits However, display switched by change key Standard: DCO to 5V Option: DC4 to 20mA, 1 to 5V and 0 to 10V Relay contact (1ch, a contact) AC100V ± 10%(Max. 10W) Auxiliaries (3m connector, 0.5mm 2 conductor) Semipermanent due to EEPROM Both vertical and horizontal (resin cover facing downward excluded) Not required PF4000D -15 PF4000D -25 PF8000D N /pulse Upper stream: 10D Down stream : 5D * 5 Equivalent to IP64 (sensor section only) * 1: If foreign matter, moisture or oil is contained in the compressed air, detecting flow rate is failed, so " sensor error " is displayed. Install a filter, refrigerating and oil mist filter before a flow sensor. * 2: Same conditions as PF8000D; 0.7, 20 C are applied. * 3: If lower than min. flow rate range, 0 is indicated. Also, for indicated value under flow rate range, accuracy is not guaranteed. * 4: Refer to descriptions of integrating pulse output on Page 1022 for details of pulse output. * 5: 1D shows pipe inner diameter, so prepare 10D= approx. 530mm and 5D= approx. 265mm long strait piping section. PF8000D -40 PF16000E -50 JIS symbol 1012

13 How to order PF 4000D 15 A1 A Flow rate range B Port size C Output [Example of model number] PF4000D-15-A1 Model: PF4000D A Flow rate range : 200 to 4000N /min B Port size : Rc1/2 C Output : Analog output DC4 to 20mA Symbol Descriptions A Flow rate range 500D 25 to 500N /min 1000D 50 to 1000N /min 2000D 100 to 2000N /min 4000D 200 to 4000N /min 8000D 400 to 4000N /min 16000E 800 to 16000N /min B Port size C Output Blank A1 A2 A3 A6 Rc3/8 Rc1/2 Rc1 Rc1 1 /2 Rc2 Analog output DC0 to 5V (standard) Analog output DC4 to 20mA Analog output DC1 to 5V Analog output DC0 to 10V Integrating pulse output Above circled combination can be manufactured. PF500D PF1000D Model PF2000D PF Series How to order PF4000D PF8000D PF16000E Refrigerating Desiccant High polymer membrane dryer Air filter Automatic drain other F.L (Module) F.L (Separate) Small F. Precise Electro pneumatic Auxiliary Flow control valve Silencer Check valve / others Joint / tube F. generator auxiliary / pad Mechanical pressure pressure dif. pres. Seating / close contact conf. Pressure for coolant for air Total air system Water cooling refrigerator for water For compressed air 1013

14 PF Series Internal structure and parts list PF500D to PF8000D No. Parts name Material No. Parts name Material 1 Platinum thin film sensor 1 Ceramic / platinum 8 O ring NBR Nitrile rubber 2 Platinum thin film sensor 2 Ceramic / platinum 9 Mesh SUS304 Stainless steel 3 Body A6063 Aluminum alloy 10 Collar A6063 Aluminum alloy 4 Attachment A6063 Aluminum alloy 11 Gasket NBR Nitrile rubber 5 Sensor base PBT PBT 12 Sensor circuit board 6 O ring NBR Nitrile rubber 13 Sensor cover ABS ABS resin 7 O ring NBR Nitrile rubber PF16000E No. Parts name Material No. Parts name Material 1 Separate flow sensor section Refer to the figure above. 6 Sub attachment SUS304 Stainless steel 2 Body 1 A6063 Aluminum alloy 7 O ring NBR Nitrile rubber 3 Body 2 A6063 Aluminum alloy 8 Orifice C3604 Copper alloy 4 Spacer A6063 Aluminum alloy 9 Aspirator C3604 Copper alloy 5 O ring NBR Nitrile rubber 10 O ring NBR Nitrile rubber 1014

15 Dimensions PF500D to PF8000D Sensor section Entrance (File name: Page 1026 or Ending 30) A 60 F 7 dia. Exit 3000 End of model no PF Series Dimensions Port size Rc3/8 Rc1/2 Rc1 Rc1 1 /2 Refrigerating Desiccant High polymer membrane dryer Air filter Automatic drain other F.L (Module) F.L (Separate) Bracket 6.5 K J 4.5 L B 47 Small F. Precise Electro pneumatic Model no. PF500D / 1000D / 2000D-** PF4000D-** PF8000D-** Monitor section N 24 M D E Port size A B C D E F G H I J K L M N I H G C M4 thread length 4.5 M4 thread length 4.5 M5 thread length 3.6 Auxiliary Flow control valve Silencer Check valve / others Joint / tube F. generator auxiliary / pad Mechanical pressure pressure dif. pres. Seating / close contact conf. 72 Panel cut dimension Standard panel cut dimension is shown as below. (Note) Appropriate panel plate thickness is 1 to 4mm. 80 and over 80 and over 80 and over and over Pressure for coolant for air Total air system Water cooling refrigerator for water For compressed air 1015

16 PF Series Dimensions PF16000E Sensor section (File name: Page 1026 or Ending 30) Note 1: This product is always used with applicable monitor PFM16000E. Note 2: When installation, the flow direction must be as same as flow direction on name plate Rc2 (S) Monitor section 72 Panel cut dimension Standard panel cut dimension is as shown below. (Note) Appropriate panel plate thickness is 1 to 4mm. 80 and over and over 80 and over 80 and over

17 for compressed air, tester kit PFK Series Air flow rate measuring component kit is available to measure the flow rate instantly at workshop. Flow rate range: 25 to 500, 50 to 1000, 100 to 2000, 200 to 4000, 400 to 8000N /min Specifications Descriptions PFK500D PFK1000D PFK2000D PFK4000D PFK8000D Flow rate range N /min 25 to to to to to 8000 Port size Applicable fluid Rc1/2 Rc1/2 Rc1/2 Compressed air / N2 gas Rc1 Rc1 1 /2 Working air quality Max. working pressure Min. working pressure Withstanding pressure Ambient temperature and humidity Atmospheric dew point -17 C or less (* 1) to 50 C 85%RH or less Fluid temperature C 0 to 40 Linearity ± 1.5%F.S (0.7 and 20 C) Pressure characteristics Temperature characteristics ± 1.5%F.S ( to 1.5, 0.7 standard) ± 2.0%F.S (0 to 40 C, 20 C standard) Response time sec Approx Analog output Switch output Power voltage Cable Standard DC0 to 5V Option: DC4 to 20mA, 1 to 5V and 0 to 10V Relay contact (1ch, a contact) AC100V ± 10% (10W or less) Auxiliaries (3m connector, 0.5mm 2 conductor) * 2 Set value holding function Installation attitude Installation strait piping section Protective structure Semipermanent due to EEPROM Both vertical and horizontal (resin cover facing downward excluded) Not required Equivalent to IP64 (sensor section only) Mass kg * 1: If foreign matter, water or oil is contained in the compressed air, detecting flow rate could be failed, so " sensor error " is displayed. Always install a filter, refrigerating and oil mist filter before a flow sensor. * 2: Extension cable (3m) can be connected. Model no. PF-FL Installation Output Accuracy Working conditions Spec. Product structure How to order PFK 4000D Case (Monitor) A Flow rate range Symbol Descriptions A Flow rate range 500D 25 to 500N /min 1000D 50 to 1000N /min 2000D 100 to 2000N /min 4000D 200 to 4000N /min 8000D 400 to 8000N /min Sensor Coupler (2 pieces) Cable (3m) Power cable (2.5m) 1018

18 Dimensions PFK Sensor section Case C Coupler B A Sensor for PFK500D to 2000D Sensor for PFK4000D Sensor for PFK8000D Knob PFK Series Dimensions A B C Rc1/ Rc Rc1 1 /2 Refrigerating Desiccant High polymer membrane dryer Air filter Automatic drain other F.L (Module) F.L (Separate) Small F. Precise Electro pneumatic Auxiliary 245 Flow control valve Silencer Check valve / others Joint / tube F. generator auxiliary / pad Mechanical pressure pressure dif. pres. Seating / close contact conf. Pressure for coolant for air Total air system Water cooling refrigerator for water For compressed air 1019

Flow sensor for compressed air

Flow sensor for compressed air for compressed air PFD/PFK (display separate type ) Sensor / CONTENTS Product introduction 1432 Applications 1434 Safety precautions 1435 (PFD)display separate type 1440 Tester kit (PFK) 1446 Electric

More information

Flow sensor for compressed air

Flow sensor for compressed air for compressed air PF-F/PFU (display integrated type ) Sensor / Overview Compressed air consumption could reach 1/5 of energy used in manufacturing plant. Controlling air is very important for energy saving.

More information

Series variation. Auxiliary valve. Quick exhaust, and circuit switchover valves, etc. are available. Port size (Rc) Page. Model Product appearance

Series variation. Auxiliary valve. Quick exhaust, and circuit switchover valves, etc. are available. Port size (Rc) Page. Model Product appearance Series variation Quick exhaust, and circuit switchover valves, etc. are available Model Product appearance Model no. Port size (Rc) Page 4 dia. dia. M /8 /4 /8 / /4 /4 / QEV-A Quick exhaust valve QEV-8A

More information

Pneumatic components (Electro pneumatic Regulator) Safety Precautions. 3 When releasing secondary control pressure,

Pneumatic components (Electro pneumatic Regulator) Safety Precautions. 3 When releasing secondary control pressure, Pneumatic components (Electro pneumatic Regulator) Safety Precautions Read this before starting use. Please refer to Intro 43 for general details on the pneumatic components, and to " Precautions" in this

More information

Vacuum pump system type

Vacuum pump system type type VS*P Vacuum component C O N T E N T S Series variation 166 20 mm width universal type (/M) 168 10.5 mm width universal type (/M) 184 31.5 mm width discrete type (VSQP) 214 11 mm pitch manifold dedicated

More information

R1000/R3000/R4000/R8000 Series

R1000/R3000/R4000/R8000 Series Regulator R/R/R/R Series Compact pressure gauge integrated type : Rc/ to Rc JIS symbol CAD DATA AVAILABLE. Specifications Descriptions R R R R Appearance Working fluid Max. working pressure Withstanding

More information

ITVX Series. Stepless control of air pressure proportional to an electrical signal. Supply pressure: 5.0 MPa

ITVX Series. Stepless control of air pressure proportional to an electrical signal. Supply pressure: 5.0 MPa 5.0 MPa Maximum Supply Pressure High Pressure Electro-Pneumatic Regulator X Series This product is only for blowing gas. This product does not have sufficient pressure control for other applications (driving,

More information

ER100 Series OUT. Specifications. Working fluid Working pressure range Control pressure range. Input voltage 2 wire Input impedance.

ER100 Series OUT. Specifications. Working fluid Working pressure range Control pressure range. Input voltage 2 wire Input impedance. Electro pneumatic regulator (nozzle flapper method) ER Series Variable controlling air pressure with electric signals ( to V DC / to ma DC) up to.mpa. Booster relay integrated and large flow rate. JIS

More information

INSTRUCTION MANUAL SMALL SIZE FLOW SENSOR RAPIFLOWR

INSTRUCTION MANUAL SMALL SIZE FLOW SENSOR RAPIFLOWR SM-385853-A INSTRUCTION MANUAL SMALL SIZE FLOW SENSOR RAPIFLOWR FSM2 Series Please read this instruction manual carefully before using this product, particularly the section describing safety. Retain this

More information

Small size flow sensor

Small size flow sensor Small size flow sensor FSM2 Sensors / flow sensor Refrigerating type dryer Desiccant type dryer High polymer membrane type dryer Air filter Auto. drain / others F.R.L. (Module unit) F.R.L. (Separate) Compact

More information

2-Color Display Digital Pressure Switch. Rated Pressure Metal Body Type (ISE75H) 2-color digital. Functions

2-Color Display Digital Pressure Switch. Rated Pressure Metal Body Type (ISE75H) 2-color digital. Functions Series ISE70/75/75H NPN/PNP open collector 2 outputs added. Cut-to-zero display function added. For General Fluids For Air 2-Color Display (Green/Red) Selectable from four patterns ON Red Green Red Green

More information

Electronic pressure switch for air

Electronic pressure switch for air pressure switch Sensors / pressure sensor Overview pressure is electrically detected, displayed and outputted. Features Various sort Wide variation is acailable from small sensor to display. CONTENTS Series

More information

2-Color Display Digital Pressure Switch. NPN/PNP open collector 2 outputs added. Cut-to-zero display function added. Rated Pressure Metal Body Type

2-Color Display Digital Pressure Switch. NPN/PNP open collector 2 outputs added. Cut-to-zero display function added. Rated Pressure Metal Body Type Series ISE70/75/75H New NPN/PNP open collector 2 outputs added. Cut-to-zero display function added. For General Fluids For Air 2-Color Display (Green/Red) Selectable from four patterns ON Red Green Red

More information

POWER REGULATOR LD -40PSU

POWER REGULATOR LD -40PSU JZ99D4121A AMPIFIRE AMPIFIRE TYPE D-4PSU ZJ-46A ISTRUCTI MAUA Manual number JZ99D4121 Sub number A Date of preparation ov. 2 Thoroughly read this instruction manual, and then use the unit correctly. Especially,

More information

Small size flow controller

Small size flow controller size FCM Sensors / CONTENTS Product introduction 1366 Applications 1368 Series variation 1369 Safety precautions 1370 FCM 1376 Technical data 1385 Functional explanation, operation 1387 Custom 1403 sensor

More information

Related vacuum products

Related vacuum products Vacuum component C O N T E N T S variation 420 Position locking valve () 422 Compact vacuum regulator () 426 Vacuum break unit () 436 Vacuum filter large volume union type (VSFB) 440 Compact vacuum filter

More information

Construction diagram Semiconductor transducer Silicone oil. Stainless steel SUS316 pressure port Hastelloy C diaphragm.

Construction diagram Semiconductor transducer Silicone oil. Stainless steel SUS316 pressure port Hastelloy C diaphragm. SERIES LED Display Anti-corrosive Digital ure Sensor DP3 ure Measurement of Corrosive Gases and Liquids Possible! Marked Conforming to EMC Directive Superior Anti-corrosive Hastelloy C Diaphragm and Stainless

More information

Compact Flow Rate Sensor. RAPIFLOW FSM3 Series Resin Body Type. Diversified High Performance. High performance. User-friendly. Compatible CC-1235A 1

Compact Flow Rate Sensor. RAPIFLOW FSM3 Series Resin Body Type. Diversified High Performance. High performance. User-friendly. Compatible CC-1235A 1 Compact Flow Rate Sensor RAPIFLOW Resin Body Type Diversified High Performance High performance User-friendly Compatible CC-1235A 1 Diversified Five types of gases can be measured with just one unit Gas

More information

PD3/PDV3-20A/25A/40A Series

PD3/PDV3-20A/25A/40A Series Pilot operated 2-port valve for dust collector control (Large port size dust collector valve) PD3/PDV3-20A/25A/40A Series Air operated/with solenoid valve Port size: Rc3/4, Rc1, : Rc1 1 /2-: φ48, Rc1 1

More information

Series ITV0000. Compact Electro-pneumatic Regulator ITV N. IITV00 02 n. How to Order F.R.L. AV AU AF AR IR VEX AMR ITV IC VBA VE VY1 G PPA AL

Series ITV0000. Compact Electro-pneumatic Regulator ITV N. IITV00 02 n. How to Order F.R.L. AV AU AF AR IR VEX AMR ITV IC VBA VE VY1 G PPA AL Compact Electro-pneumatic Regulator Series For single unit and single unit for manifold Pressure range 9 Option. MPa. MPa.9 MPa kpa Option How to Order N Power supply voltage 24 VDC ±% 2 to VDC Option

More information

CVE2/CVSE2 CVE3/CVSE3

CVE2/CVSE2 CVE3/CVSE3 Overview This is a reliable 2, 3 port coolant valve with cylinder drive method. This valve for tool machine cutting oil or coolant control incorporates a metal seal to prevent the entry of cutting chips,

More information

2-Color Display High-Precision Digital Pressure Switch

2-Color Display High-Precision Digital Pressure Switch 2-Color Display High-Precision Digital Pressure Switch Settings can be copied to up to 1 slave sensors at once. The settings of the master sensor can be copied to the slave sensors. Reduced setting efforts

More information

Sensor specifications Model no.

Sensor specifications Model no. Miniature size Analog output type/switch output type FSM-V Series (air/nitrogen gas) Flow rate range:.5,.1,.5, 1, 5, /min. Pressure Sensor specifications Model no. Flow rate range ( /min) Note -.5 to +.5

More information

VSG Series Features Descriptions VSG VSG VSG Descriptions Supply valve Descriptions Vacuum filter

VSG Series Features Descriptions VSG VSG VSG Descriptions Supply valve Descriptions Vacuum filter Basic performance oriented general vacuum ejector unit Series Nozzle diameter: ø.5, ø, ø1. acuum switch and vacuum break valve, etc. are unitized, so types matching the work purpose is selectable. Features

More information

ETR Series ELECTRO-PNEUMATIC TRANSDUCING REGULATORS. Electro-Pneumatic Transducing Regulators

ETR Series ELECTRO-PNEUMATIC TRANSDUCING REGULATORS. Electro-Pneumatic Transducing Regulators ELECTRO-PNEUMTIC TRNSDUCING REGULTORS ETR Series Electro-Pneumatic Transducing Regulators fusion of air and electronics Flexibly control pressure. sequencer (PC) allows remote control operation. Feedback

More information

ELECTRO-PNEUMATIC TRANSDUCING REGULATORS CONTENTS ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS.

ELECTRO-PNEUMATIC TRANSDUCING REGULATORS CONTENTS ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS. CCESSORIES GENERL CTLOG IR TRETMENT, UXILIRY, VCUUM, ND FLUORORESIN PRODUCTS ELECTRO-PNEUMTIC TRNSDUCING REGULTORS CONTENTS ETR Series Features, Operation Principle 237 pplication Examples 238 Handling

More information

2-Color Display High-Precision Digital Pressure Switch

2-Color Display High-Precision Digital Pressure Switch 2-Color Display High-Precision Digital Pressure Switch Series ZSE3/ISE3 2-color digital display allows you to choose the setting according to your application requirements. 4 different display settings

More information

2-Color Display Digital Pressure Switch. Rated Pressure Metal Body Type. MPa MPa (ISE75H) 2-color digital. Functions

2-Color Display Digital Pressure Switch. Rated Pressure Metal Body Type. MPa MPa (ISE75H) 2-color digital. Functions -Color Display Digital Pressure Switch /75/75H Series NPN/PNP open collector outputs added. Zero-cut off display function added. For General Fluids For Air Rated Pressure Metal Body Type 0 5 (E75) () -Color

More information

EV2100V Series OUT VAC EV2100V. Specifications. 196kPa 196kPa Control pressure range Assured pressure range Power voltage Current consumption

EV2100V Series OUT VAC EV2100V. Specifications. 196kPa 196kPa Control pressure range Assured pressure range Power voltage Current consumption pneumatic regulator (solenoid type for vacuum) EVV Series JIS symbol EVV CAD DATA AVAILABLE. How to order Overview For electro pneumatic regulator EVV series, feedback control with semiconductor pressure

More information

MICRO EJECTORS. Micro ejector single unit (without solenoid valve) ME. Micro ejector with solenoid valve DC24V. Block-off plate ME MA-BP

MICRO EJECTORS. Micro ejector single unit (without solenoid valve) ME. Micro ejector with solenoid valve DC24V. Block-off plate ME MA-BP Micro Ejector Order Codes Manifold Order Codes Micro ejector single unit (without solenoid valve) ME Body model nozzle diameter : Maximum flow rate on vacuum side 03 0.3 : 3.0R/min. [0.012in., 0.106ft.

More information

Series ZSE30/ISE30. High Precision, 2-color Display Digital Pressure Switch. With One-touch fittings are newly introduced. PSE

Series ZSE30/ISE30. High Precision, 2-color Display Digital Pressure Switch. With One-touch fittings are newly introduced. PSE High Precision, 2-color Display Digital Pressure Switch Series SE30/ISE30 SE ISE PSE I SE3 PS I SE 1 2 SP ISA2 IS SM PF2 IF Data With One-touch fittings are newly introduced. Straight type Elbow type 16-2-1

More information

3MA0/3MB0. Small pneumatic valve. 3 port direct acting valve CONTENTS. Space saving Valves are compactly designed with widths of 10 mm

3MA0/3MB0. Small pneumatic valve. 3 port direct acting valve CONTENTS. Space saving Valves are compactly designed with widths of 10 mm M0/MB0 Small pneumatic valve M Overview The M0 and MB0 Series port valve is a 0 mm wide miniature direct-acting poppet valve compatible with system downsizing. variety of types, including discrete and

More information

COMPACT BUT CUT OFF DC POWER CURRENT, POWER CAPSULE CONTACT RELAY

COMPACT BUT CUT OFF DC POWER CURRENT, POWER CAPSULE CONTACT RELAY COMPACT BUT CUT OFF DC POWER CURRENT, POWER CAPSULE CONTACT RELAY EB RELAYS (AEB) (1A type) FEATURES Compact and high capacity using double contacts in series and permanent magnet installed. (1,A/3 times)

More information

HN B G1/US B G2/US B G3

HN B G1/US B G2/US B G3 HN B G/US B G/US B G Compact direct acting, port solenoid valve air, water,, low vacuum (. x 0 Pa (abs)) CONTENTS Safety precautions port solenoid valve HNB NC (normally closed) type USB NC (normally closed)

More information

Design & Selection. Installation & Adjustment

Design & Selection. Installation & Adjustment U SM Series WRNING This product must not be used submerged in water, oil or powder, or where coolant, coolant fluid or swarf, etc., may come in contact. lways incorporate an interlock in the control circuit

More information

EVS RP6020. Instruction Manual

EVS RP6020. Instruction Manual Instruction Manual TDK Lambda BEFORE USING THE PRODUCT Be sure to read this instruction manual thoroughly before using this product. Pay attention to all cautions and warnings before using this product.

More information

2-Colour Display Type High-Precision Digital Pressure Switch Series ZSE30/ISE30 How to Order Option 1 Without lead wire Nil Lead wire with connector (Lead wire length: 2m) L For positive pressure For vacuum/low

More information

Digital Flow Switch (Sensor Part) Operation Manual

Digital Flow Switch (Sensor Part) Operation Manual Digital Flow Switch (Sensor Part) Operation Manual For Air PF2A 50/5 Series PF2A 5/ 52/ 55 Series For Water PF2W /520/50 Series PF2W 5 Series For Water (High Temperature Fluid Type) PF2W T/520T/50T Series

More information

2-Color Display High-Precision Digital Pressure Switch Series ZSE40A(F)/ISE40A

2-Color Display High-Precision Digital Pressure Switch Series ZSE40A(F)/ISE40A 2-Color Display High-Precision Digital Pressure Switch Series ZSEA(F)/ISEA New M8 connector type RoHS IP65 Applicable fluid Air, Non-corrosive gas, Non-flammable gas Can copy to up to 10 switches simultaneously.

More information

Series 10-ZSE40A(F)/10-ISE40A

Series 10-ZSE40A(F)/10-ISE40A Series 10-ZSEA(F)/10-ISEA RoHS 2-Color Display High Precision Digital Pressure Switch How to Order For positive pressure Clean series For vacuum/ compound pressure 01 N01 W1 10 Rated pressure range ISEA

More information

The Multivariable Air Flow Meter

The Multivariable Air Flow Meter The Multivariable Air Flow Meter Model MVC10A/MVC10F OVERVIEW The Multivariable Mass Flow Meter model MVC10A/ MVC10F, a compact has all function necessary to measure nitrogen (N 2 ) gas, carbon dioxcide

More information

INSTRUCTION MANUAL. Flow sensor FUS20 series HIR

INSTRUCTION MANUAL. Flow sensor FUS20 series HIR HIR0057-00 INSTRUCTI MANUAL sensor FUS0 series P l e a s e b e s u r e t o r e a d t h i s User's Manual before using the sensor. E specially, be sure to read safety instructions carefully. P lease keep

More information

Low Differential Pressure Sensor ±1% F.S.

Low Differential Pressure Sensor ±1% F.S. CAT.ES100-49 A Low Differential Pressure Sensor Rated differential pressure range: 0 to 2 kpa Accuracy: ±1% F.S. LED display to confirm energization Series PSE550 Proof pressure: 65kPa Output: 1 to 5VDC

More information

3-step setting. 2-Color Display High-Precision Digital Pressure Switch. Series ZSE30A(F)/ISE30A. Added vacuum range.

3-step setting. 2-Color Display High-Precision Digital Pressure Switch. Series ZSE30A(F)/ISE30A. Added vacuum range. 2-Color Display High-Precision Digital Pressure Switch Series ZSE3A(F)/ISE3A RoHS Can copy to up to 1 switches simultaneously. The settings of the master sensor can be copied to the slave sensors. Reducing

More information

2-Color Display Digital Flow Switch

2-Color Display Digital Flow Switch -Color Display Digital Flow Switch Series Flow rate range:, 5, 5, l/min. Minimum unit setting:. l/min. (. l/min when the flow rate range is 5, 5, l/min.) Repeatability: ±%F.S. or less Grease-free Flow

More information

ITVH Series. 3.0 MPa Maximum Supply Pressure High Pressure Electro-Pneumatic Regulator. 3.0 MPa 0.2 to 2.0 MPa. 3 W or less L /min (ANR)*

ITVH Series. 3.0 MPa Maximum Supply Pressure High Pressure Electro-Pneumatic Regulator. 3.0 MPa 0.2 to 2.0 MPa. 3 W or less L /min (ANR)* 3.0 MPa Maximum Supply Pressure High Pressure Electro-Pneumatic Regulator ITVH Series ARJ RoHS Maximum supply pressure Set pressure range Stability 3.0 MPa 0.2 to 2.0 MPa ARX AMR Stepless control of air

More information

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve 5.0 MPa Pilot Operated / Port Solenoid Valve & Check Valve Series VCH VCH4/4: Port VCH40: Port VCHC40: Check Valve Pilot Operated Port Solenoid Valve Series VCH40 Stable responsiveness Response time dispersion

More information

RP Instruction Manual

RP Instruction Manual Instruction Manual TDK Lambda BEFORE USING THE PRODUCT Be sure to read this instruction manual thoroughly before using this product. Pay attention to all cautions and warnings before using this product.

More information

Head-separated Digital Pressure Sensor DP5 SERIES DPH SERIES

Head-separated Digital Pressure Sensor DP5 SERIES DPH SERIES 76 ORDER GUIDE DP / configuration diagram Intermediate cable s Type Vacuum pressure Positive pressure Compound pressure Appearance An intermediate cable is required to connect the controller and the sensor

More information

Body width of 10mm, Nl/min (49.08) 2W (Standard) Nl/min (78.52) 4W (U type: Large flow) Vacuum applications possible (up to 100kPa) 3 S.

Body width of 10mm, Nl/min (49.08) 2W (Standard) Nl/min (78.52) 4W (U type: Large flow) Vacuum applications possible (up to 100kPa) 3 S. High speed coil with stable response times ON: 4ms, OFF: 2ms, Dispersion accuracy: ±1ms (With light and surge voltage suppressor at a supply pressure of 0.5MPa, subject to clean, dry air) 4 Port Direct

More information

Circuit of directional control valve and regulator. Simplifying circuit design. Space saving and piping. work eliminated. Automating pressure control

Circuit of directional control valve and regulator. Simplifying circuit design. Space saving and piping. work eliminated. Automating pressure control Port Electro-Pneumatic Proportional Valve Series 000/000 Capable of actuating a cylinder and performing analog control of pressurization alone can be used to switch and actuate a cylinder and to perform

More information

Soft Start-up Valve. AV2000/3000/4000/5000 Series

Soft Start-up Valve. AV2000/3000/4000/5000 Series Soft Start-up Valve V000/000/000/000 Series [Option] C- R- W- C R - W - Start-up valve for low speed air supply to gradually raise initial pressure in an air system and for quick exhaust by cutting off

More information

HVB/HVL. Solenoid valve for high vacuum. For vacuum, inert gas, air, nitrogen CONTENTS. Overview

HVB/HVL. Solenoid valve for high vacuum. For vacuum, inert gas, air, nitrogen CONTENTS. Overview HV/HVL For vacuum, inert gas, air, nitrogen HN/G US/G F/G Overview dvanced technology, such as stability in the leak amount (vacuum holding force) and increased seal life, is required when the degree of

More information

The Multivariable Air Flow Meter

The Multivariable Air Flow Meter No. SS2-MVC200-0100 OVERVIEW The Multivariable Mass Flow Meter AIRcube, a compact has all function necessary to measure nitrogen (N 2 ) gas, carbon dioxcide (CO 2 ) gas and air. The model MVC10A/MVC10F

More information

Piping labor reduced A flexible system has been adopted. E-P HYREG. Cylinder behavior and pressurization control. Example

Piping labor reduced A flexible system has been adopted. E-P HYREG. Cylinder behavior and pressurization control. Example E-P HYREG VY Series This hybrid regulator combines a regulator and a solenoid valve. Stepless control through electric signals Port sizes M5 to inches can be covered by combining an ultra-compact electro-pneumatic

More information

Series AV2000/3000/4000/5000

Series AV2000/3000/4000/5000 Soft Start-up Valve Series AV/3/4/5 Series introduced! A start-up valve that gradually increases supply pressure during start up and rapidly exhausts system air when the supply air is shut off AC AV AU

More information

Technical Information Solid State Relays. Glossary. Solid State Relays

Technical Information Solid State Relays. Glossary. Solid State Relays Glossary Terms Meaning Circuit functions Photocoupler Transfers the input signal and insulates inputs and outputs as well. Photoctriac coupler Zero cross circuit Trigger circuit Snubber circuit A circuit

More information

FLOW METERS. 90 left. 90 right. Sensor. Rotary display. Models. FA Series

FLOW METERS. 90 left. 90 right. Sensor. Rotary display. Models. FA Series FLOW METERS FA Series Sensor A thermal mass sensor enables accurate measurement even in the case of gas temperature and pressure fluctuations. Sensor structure The FA Series measure flow rates using heat

More information

Power Controller. (see note 1) 10 sec

Power Controller. (see note 1) 10 sec Power Controller Single-phase Models EUN Series AC Power Controller with Phase-control System Allows Precise Temperature Control Models with Base-up and Soft-start Functions Available EH Series Phase Control

More information

ISE6B. Series ZSE6B. Digital Pressure Switch. With Backlight. (For vacuum) (For positive pressure) For General Purpose Fluids

ISE6B. Series ZSE6B. Digital Pressure Switch. With Backlight. (For vacuum) (For positive pressure) For General Purpose Fluids Leakage rating: 1 X 10-9 atm cc/s With Backlight Digital Pressure Switch Series ZSE6B (For vacuum) ISE6B (For positive pressure) Sensor and fitting section are electron beam welded. 2 kinds of metal gasket

More information

Micro-differential Pressure High-precision Digital Pressure Sensor For Gas DP-M SERIES

Micro-differential Pressure High-precision Digital Pressure Sensor For Gas DP-M SERIES MODE 751 Micro-differential Pressure High-precision Digital Pressure Sensor For Gas SERIES Related Information General terms and conditions... F-7 Glossary of terms... P.1469 ~ Sensor selection guide...

More information

Micro-differential Pressure High-precision Digital Pressure Sensor For Gas DP-M SERIES

Micro-differential Pressure High-precision Digital Pressure Sensor For Gas DP-M SERIES MODE 729 Micro-differential Pressure High-precision Digital Pressure Sensor For Gas SERIES Related Information General terms and conditions... F-3 Glossary of terms... P.1563~ guide... P.699~ General precautions...

More information

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve 5.0 Ma ilot Operated /3 ort Solenoid Valve & Check Valve Series VCH VCH4/4: ort VCH40: 3 ort VCHC40: Check Valve ilot Operated ort Solenoid Valve [Option] Series VCH40 Stable responsiveness Response time

More information

3 Port Solenoid Valve

3 Port Solenoid Valve Port Solenoid Valve V00 Series Rubber Seal Power consumption 0. W (with power saving circuit) Note) Refer to page 7 for details. temperature rises: C (with power saving circuit) Sonic conductance Series

More information

Model Number Structure. Power Controllers G3PX. Single-phase Models. Model Number Legend

Model Number Structure. Power Controllers G3PX. Single-phase Models. Model Number Legend Power Controllers GPX Refer to Safety Precautions (page 0). Single-phase Models EUN Series AC Power Controllers with Phase-control System Allow Precise Temperature Control Models with Base-up and Soft-start

More information

New Products COMPACT PILOT OPERATED SOLENOID VALVE FOR WATER. Lightweight and large flow rate, low power consumption Improved corrosion resistance!

New Products COMPACT PILOT OPERATED SOLENOID VALVE FOR WATER. Lightweight and large flow rate, low power consumption Improved corrosion resistance! New Products Compact Pilot Operated Solenoid Valve for Water FWD Series New Product COMPACT PILOT OPERATED SOLENOID VALVE FOR WATER Lightweight and large flow rate, low power consumption Improved corrosion

More information

Differential Pressure Transmitter

Differential Pressure Transmitter Specifications/Instructions Differential Pressure Transmitter General Model PY9000D is a differential pressure transmitter that uses a ceramic cantilever sensor. Deflection of the ceramic cantilever caused

More information

Energy efficiency and Flow

Energy efficiency and Flow Energy efficiency and Flow or more Estimating figure with ø6 push-in fittings Primary pressure: 0.5MPa Secondary pressure: Release to atmospheric pressure Oil-prohibition type Suitable for oil-restricted

More information

Clean Air Module. Digital flow switch Regulator ON/OFF valve Restrictor Filter

Clean Air Module. Digital flow switch Regulator ON/OFF valve Restrictor Filter Clean Air Module Series Digital flow switch Regulator ON/OFF valve Restrictor Filter Modularizes clean equipment (Reduced piping man-hours/space-saving). Easily obtains clean air. Built-in one-touch fitting

More information

Basic Characteristics Data

Basic Characteristics Data Basic Characteristics Data Basic Characteristics Data Model 1F 15F 2F 3F Circuit method Switching frequency [khz] Active filter 6 Forward converter 13 Active filter 6 Forward converter 13 Active filter

More information

DRB-1 Series Instruction Manual

DRB-1 Series Instruction Manual Instruction Manual BEFORE USING THE POWER SUPPLY UNIT Pay attention to all warnings and cautions before using the unit. Incorrect usage could lead to an electrical shock, damage to the unit or a fire hazard.

More information

Compact Direct Operated 2/3 Port Solenoid Valve for Water and Air

Compact Direct Operated 2/3 Port Solenoid Valve for Water and Air Compact Direct Operated / Port Solenoid Valve for Water and Air 0/0/0: Port, 00/00: Port 0/0/0 -port type has been remodeled to new compact and lightweight series. For details about new series, refer to

More information

EX Series. Electric Actuators for Ball and Butterfly Valves

EX Series. Electric Actuators for Ball and Butterfly Valves EX Series Electric Actuators for Ball and Butterfly Valves Next-Generation Electric Actuator Realization of Upgraded General-Purpose Actuators The modularization and adoption of the common parts have brought

More information

L1000/L3000/L4000/L8000-W Series

L1000/L3000/L4000/L8000-W Series Lubricator standard white Series L1/L3/L4/L8-W Series Supplies fine oil mist. Port size: 1/8 to 1 JIS symbol Specifications Descriptions L1-W L3-W L4-W L8-W Appearance Working fluid Compressed air Max.

More information

MULTISTAGE MICRO EJECTORS

MULTISTAGE MICRO EJECTORS MULTISTAGE MICRO EJECTORS MED07-E, MED10-E Specifications Basic model Item Media Operating pressure range MPa [psi.] Proof pressure MPa [psi.] Operating temperature range (atmosphere and media) C [ F]

More information

10 switches simultaneously. The settings of the master sensor (source of copy) can be copied to the slave sensors. Reducing setting labor

10 switches simultaneously. The settings of the master sensor (source of copy) can be copied to the slave sensors. Reducing setting labor 2-Color Display High-Precision Digital Pressure Switch ZSE ISE RoHS ZSE ISE IP65 ZSE40 ISE40 M8 connector type ZSE10 ISE10 ISE70 ZSE80 ISE80 PS ISA3 ISA2 ISE35 Applicable Air, Non-corrosive gas, Non-flammable

More information

MULTISTAGE MICRO EJECTORS CONTENTS ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS. Caution

MULTISTAGE MICRO EJECTORS CONTENTS ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS. Caution ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS MULTISTAGE MICRO EJECTORS CONTENTS MED07-E, MED10-E Series Specifications 715 Order Codes 716 Operation Principle

More information

Series VP4 50/4 70. Large Size 5 Port Solenoid Valve Rubber Seal SJ SY SY SV SYJ SZ VF VP4 S0700 VQ VQ4 VQ5 VQC VQC4 VQZ SQ VFS VFR VQ7 VP4

Series VP4 50/4 70. Large Size 5 Port Solenoid Valve Rubber Seal SJ SY SY SV SYJ SZ VF VP4 S0700 VQ VQ4 VQ5 VQC VQC4 VQZ SQ VFS VFR VQ7 VP4 Type of actuation 4 Piping 0 Side ported Bottom ported 4 Without sub-plate Large Size 5 Port Solenoid Valve Rubber Seal Series 50/4 70 Series VP 5 port solenoid valve 5 7 position single position double

More information

PAF F280 SERIES Instruction Manual

PAF F280 SERIES Instruction Manual PAF450 600F280ERIES PAF450 600F280 SERIES Instruction Manual Before using this product Be sure to take note of precautions and warnings indicated in this manual when using this product. Improper usage

More information

New Products. 3 Port Solenoid Valve with Spool Position Detection SNP Series

New Products. 3 Port Solenoid Valve with Spool Position Detection SNP Series New roducts 3 ort Solenoid Valve with Spool osition Detection SN Series New roduct Reliable detection of open and close status by spool position detecting. Two safety cut off by modular connection! Main

More information

2-Color Display Digital Pressure Switch

2-Color Display Digital Pressure Switch -Color Display Digital Pressure Switch Series ZSE80(F)/ISE80(H) Stainless diaphragm Oil-free (Single-layer diaphragm structure) Sensor parts: Stainless steel 630 Fitting parts: Stainless steel 304 The

More information

Vacuum applications possible (up to 100kPa) Base mounted. Cylinder bore size (mm) Series CM2. Pressure: 0.5MPa Load ratio: 50% Cylinder stroke: 300mm

Vacuum applications possible (up to 100kPa) Base mounted. Cylinder bore size (mm) Series CM2. Pressure: 0.5MPa Load ratio: 50% Cylinder stroke: 300mm 4 Port Direct Operated Poppet Solenoid Valve Series D1000 High speed coil with stable response times ON: 4ms, OFF: 2ms, Dispersion accuracy: ±1ms (With light and surge voltage suppressor at a supply pressure

More information

3 Port Solenoid Valve Pilot Operated Poppet Type. External pilot

3 Port Solenoid Valve Pilot Operated Poppet Type. External pilot 3 Port Solenoid Valve Pilot Operated Poppet Type Series VG342 Rubber Seal [Option] Low power consumption 4.8 W DC (Standard type) 2 W DC (Energy-saving type) No lubrication required Possible to use in

More information

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications Port Solenoid Valve Direct Operated Poppet Type Series 000 Rubber Seal [Option] C: 0. dm /(s bar) (Passage {/ / (A/B R/R)}) Compact: Width 8 x Length 8 (mm) Low power consumption W DC (Standard type) W

More information

10 VQ F. Nil Latching type: Push-locking type (Tool required) B. Nil. Electrical entry

10 VQ F. Nil Latching type: Push-locking type (Tool required) B. Nil. Electrical entry Series 0-VQ00 port solenoid valve How to Order Valves 0 VQ 0 F ir cylinder Clean series Series VQ Compact port valve Type of actuation Normally closed Note) Normally open Note) Normally open type is available

More information

Unit specifications. Nil. Option 1. Power supply/output connection cable. Option 2

Unit specifications. Nil. Option 1. Power supply/output connection cable. Option 2 Series -PSE3 RoHS Remote Type 2-Color Display Digital Pressure Sensor Controller How to Order 2 3 4 5 Nil Options/Part No. L Input/Output specifications NPN2 output to 5 V output NPN2 output 4 to 2 m output

More information

TECHNICAL GUIDE FOR PROXIMITY SENSORS DEFINITIONS YAMATAKE PROXIMITY SENSOR CATEGORIES

TECHNICAL GUIDE FOR PROXIMITY SENSORS DEFINITIONS YAMATAKE PROXIMITY SENSOR CATEGORIES TECHNICAL GUIDE FOR PROXIMITY SENSORS DEFINITIONS "" includes all sensors that detect the presence of a metallic object approaching the sensing face or near the sensing face without mechanical contact.

More information

5 Port Direct Operated Poppet Solenoid Valve, Rubber Seal

5 Port Direct Operated Poppet Solenoid Valve, Rubber Seal Port Direct Operated Poppet Solenoid Valve, Rubber Seal Series 3000 or details about certified products conforming to international standards, visit us at www.smcworld.com. C: 0.4 dm 3 /(s bar) (Passage

More information

SERIES LED Display Digital Pressure Sensor. Clearly Visible LED Display with 3 1 /2 Digits

SERIES LED Display Digital Pressure Sensor. Clearly Visible LED Display with 3 1 /2 Digits SERIES LED Display Digital Pressure Sensor Complete Functionality from a Wide Model Line-up Marked Conforming to EMC Directive High Accuracy High Resolution High Speed It achieves a 2.5ms, or less, response

More information

ABB ! CAUTION. Type KRV Directional Overcurrent Relay E 1.0 APPLICATION 2.0 CONSTRUCTION AND OPERATION. Instruction Leaflet

ABB ! CAUTION. Type KRV Directional Overcurrent Relay E 1.0 APPLICATION 2.0 CONSTRUCTION AND OPERATION. Instruction Leaflet ABB Instruction Leaflet 41-137.2E Effective: February 1994 Supersedes I.L. 41-137.2D, Dated February 1973 ( )Denotes Change Since Previous Issue. Type KRV Directional Before putting relays into service,

More information

High-speed detection even a little liquid leak

High-speed detection even a little liquid leak 737 Leak Sensor Related Information Amplifier Built-in EX-F70 SERIES SERIES Sensor selection guide...p.11~ / P.77~ General terms and conditions...p.1 General precautions...p.986~ PHOTO PHOTO Conforming

More information

HL (AZH) Limit Switches

HL (AZH) Limit Switches COMPACT SIZE LIMIT SWITCHES HL (AZH) Limit Switches Wide selections of actuators, terminals and bodies to meet any application Excellent environmental resistance Die casting caseiec IP67 Plastic caseiec

More information

D4BL. Protective Doors Are Locked Until Machines Completely Stop Operating. Guard Lock Safety-door Switch. Model Number Structure.

D4BL. Protective Doors Are Locked Until Machines Completely Stop Operating. Guard Lock Safety-door Switch. Model Number Structure. Guard Lock Safety-door Switch Protective Doors Are Locked Until Machines Completely Stop Operating A mechanical lock is applied automatically when the Operation Key is inserted. A high level of safety

More information

Various applications. Robust housing. The GX-4S uses a robust stainless steel housing. The tightening torque can be 0.58 N m or less.

Various applications. Robust housing. The GX-4S uses a robust stainless steel housing. The tightening torque can be 0.58 N m or less. INUCTIVE SERIES Compact Inductive Proximity Sensor Flexible cable Metal embedding type available possible Amplifier Built-in High functionality together with robust housing and flexible cable GA-/GH -N

More information

SRT1000 Series THERMAL FLOWMETER

SRT1000 Series THERMAL FLOWMETER High-performance gas flowmeter SRT1000 Series THERMAL FLOWMETER OUTLINE Based on the long experienced know-how on the TOKYO KEISO's thermal flowmeters, SRT1000 series has enhanced its performance such

More information

Operating Instructions Vaccon VDS-1000 Solid State Combination Vacuum Switch/Sensor w/ Digital Display

Operating Instructions Vaccon VDS-1000 Solid State Combination Vacuum Switch/Sensor w/ Digital Display Operating Instructions Vaccon VDS-1000 Solid State Combination Vacuum Switch/Sensor w/ Digital Display Installation The VDS-1000 combines either two (2) low voltage, high side or low side, switched outputs

More information

Simple Pressure Level Setting. The threshold level is able to adjust simply. Just set the pointer suitable for the displayed pressure level.

Simple Pressure Level Setting. The threshold level is able to adjust simply. Just set the pointer suitable for the displayed pressure level. SERIES LED Bar Display Mechanical Switch is Out of Date Choose the Contemporary Pressure Sensor with LED Bar Display Marked Conforming to EMC directive Bright LED Bar Display Easy to read the pressure

More information

HL (AZH) LIMIT SWITCHES

HL (AZH) LIMIT SWITCHES COMPACT SIZE LIMIT SWITCHES LIMIT SWITCHES U L PRODUCT TYPE 1. Limit Switches Actuator Type Push plunger Roller plunger Cross roller plunger Panel mount push plunger Panel mount roller plunger Panel mount

More information

Model Pressure range ON/OFF output Linear output

Model Pressure range ON/OFF output Linear output Digital Sensor Sensor with Easy-to-Read LED Display status can be checked at a glance from the red digital pressure value and analog bar displays. Measurement pressure is averaged by the chattering prevention

More information

EV2000 Series. Specifications. Descriptions Working fluid Max. working pressure Min. working pressure Withstanding pressure

EV2000 Series. Specifications. Descriptions Working fluid Max. working pressure Min. working pressure Withstanding pressure (solenoid valve type medium flow) High precision air pressure proportional enabling ultimate space saving of device. nic sensor Pressure JIS symbol Overview In this electro, feedback control with semiconductor

More information