www. ElectricalPartManuals. com INSTRUCTIONS Westinghouse 1. L C
|
|
- Hester Walker
- 5 years ago
- Views:
Transcription
1 Westinghouse 1. L C NSTALLATON OPERATON MANTENANCE NSTRUCTONS SWTCHBOARD WAlTHOUR METERS TYPES D2B-2F; D2B-7F AND D2B-8F N FT -21 FLEXTEST CASE Fig. 1. FT-27 Case. Fig Chassis. APPLCATON CHART METER TYPE NUMBER OF ST A. TORS CRCUT A.PPLCA. TON D2B-2F 2 2- or 3-Phase, 3-Wire 3-Phase, 4-Wire Delta 3-Phase, 4-Wire Wye D2B-7F 2 3-Phase, 4-Wire Delta D2B-8F 2 3-Phase, 4-Wire Wye P.F. LOOP S ENCLOSED N PLASTC TUBE BEHND FRAME SUPERSEDES.L EFFECTVE JULY 1967
2 TYPE 028 FLEXTEST SWTCHBOARD METERS --- GENERAL The meter elements are mounted on a rem ova b 1 e chassis, which is held in th case by two latches. All connections between the case and the chassis are made through the test switches. Automatic shorting switches are provided on all current circuits to prevent opening current transformers when testing or removing the chassis. For testing, leads can be clipped to the test lugs above the chassis jaws and on the switch blades. Two test plugs are available to facilitate calibration of these meters. A 10-circuit plug is inserted into the chassis jaws and is provided with binding post terminals for connections to the test circuit. Current me a sure me n t s are made by connecting ammeters to a current circuit test plug, which is then inserted into the current switch assembly, between the chassis and the case. The hardware s u p p 1 i e d with the meter permits semi-flush mounting on panels up to 3/16 inch thick. For projection mounting on panels thicker than 3/16 inch, special hardware is furnished upon request (specify panel thickness). Provisions have been made on all FT-21 cases for convenient field installation of either 2- or 3-wire pulse initiators. Removal of three knockouts (located in the back of the case, near the top) will permit installation of an output terminal-block and pin assembly. A mating bracket and socket assembly is then attached to the meter frame and latch assembly. The output circuits will be closed by inserting the meter frame and latch assembly into the case. All necessary parts are available in kit form for each type of pulse initiator. t is not practical to make a field installation of type CD-21 because a special disk is required. CALl BRA TON All meters are calibrated on single phase. The basic watt hour constant (K h ) for these meters is.6 per nominal 600 watt rating. The single-phase test speed is 16 2/3 rpm except for the D2B-8, which is 22 2/9 rpm. Both of these are given on a 120-volt basis. 2 The following 1s a guide to watthour stator calibration. Detailed calibration procedure is available in L ADJUSTMENTS Full Load, Light Load and Balance All of these adjustments are made at the front of the meter. The full load adjuster knob is in the center; the light load knob at the left; and the balance knob at the right. Direction of adjustment is indicated by the arrow on the nameplate ("F" indicates fast). Power Factor Power factor adjustment is made by changing the r e s i s tan c e of the soldered loop located at the back of each electromagnet. ncreasing the resistance (lengthening the loop) increases the speed on lagging power factors. REPLACEMENT PARTS AND REPARS Where facilities are limited or where only a small number of meters are used, it is recommended that the meters be returned to the factory for repairs. When returning a meter for repairs, obtain a Returned Material Tag for the District Office so as to avoid delay in identifying the shipment. GENERAL DATA COMBNED STATORS OF S. AMP VOLT- 60 CYCLE METERS TYPE 02B-2F 028-SF STARTNG WATTS WAlTHOUR CONSTANT (Kh) FULL LOAD R.P.M. ON SNGLE PHASE TEST FOR TRANSFORMER BURDENS SEE THE TABLE ON PAGE /3 22 2/9
3 TYPE D2B FLEXTEST SWTCHBOARD METERS _.L_._4_2-_20_1_.3_ C c type FT-U case dimensivna panel cutout dimensions terminal and mounting hardware front view aide view aemi fluah projection TRANSFORMER BURDENS FOR 60-CYCLE METERS VOLT AGE COl L Cl RCU TS, NCLUDNG P.l. LAMP. FOR RATED MULTPLES OF 120. V. 411 R 4 LJ.. "--j--' t 0 0 Fig. 3. Mounting of FT-21 Case. VOL T-AMPS. WATTS POWER FACTOR CURREN T COL CRCUTS EAOt FULL HALF STATOR COL COL 5. AMPS. ON 5. AMP. COL. VOL T-AMPS WATTS POWER FACTOR AMPS. ON 2.5 AMP. COL. EACH STATOR VOLT-AMPS WATTS z CRC POWER FACTOR li2... '1CRCUT CLDSNG Of: VCE,7cultlt[NT TEST } "'ACK L for semi-flush mounting _,90-32wo --panel VOLTAGE TRANSFORMER CONNECTON ELOW Fig. 4. REAR VEW TyDe D2B-2F, 3-Phose, 3-Wire 1-18 screw (far thick panel use i\ -18 stud) screw (for thick panel use stud) UT(NAL JUPfltl to-..., 3
4 TYPE D2B FLEXTEST SWTCHBOARD METERS... CAC,JlT CLDSNG 1 Q[V((,1 CURfi NT f[sf JA(C NEUT"AL Fig. 5. lrotot[ SWTCHES CRCUT CLOSNG OP[AAT 0 T T(S T SWTCH HANDLE 1!11 ALSO BY REMOVAL (litutnal -- J 9-5 VOLTAGE TRANSFORMER CONNECTON BE LO W : [Jlf REAR VEW J 01'" CHASSS JUMPERS Type D2B-2F, 3-Phase, 4-Wire, Delta, CRCUT 0[1t'C[ JACK CLOS "'G,!cuRRUH HST 1f1 1i1 1 1 VOLTAGE TRANSFORMER CONNECTON BELOW Fig. 7. rff_: _j' t'j -vw--- t:: [1 F=:-1 REAR VEW NEUTRAL!!EYT!Ub DfMAND MOTOR 5o 'f AfTQR "A'H(N USf!l NOT CRCUT CLOSNG SW' (H( S OP[RAT 0 8Y HST SWTCH H.ll.llo'Dl[ 8.LSO BY REMOVAl OF CHASSS fll TfRNAL 7-'1 - OfMANO -CONTACTS- -:!:.- Type D28-7F, 3-Phase, 4-Wire, Delta WESTNGHOUSE METER DVSON -( R( Jol ) VOLTAGE TRANSFORMER CON NECTON BELOW f [ }. : ==: Fig. 6. OFY'C( CtOSHG.r('J:UH'"t Tf ST 1 JACM VOLTAGE =± REAR VEW NEUTRAL Type D2B-2F, 3-Phase, 4- Wire, Wye. i[) D[MANO K TRA NSFORMER CON NECTON - r-- - J" ' FJ77?7 === Fig. 8. ELECTRC OEM.lNO WOTOR 1!11 R,1 TQR WH[N USED NOTE Q[,ANO MOTOR 8 REACTOR LEADS CONNECTED ACROSS - 5 FOR 12 VOLT SERVCE NOTE CRCUT CLOS.. G SWTCHES OP(RAT 0 8T TEST SWTCH H"l'oiOL[ 8 Al- SO 8T REMOVAL Of CHASSS 1(f[RNAL t T- S, 10 2 BELOW.! JUMPERS NlUTftAL _ REAR VE W Type D2B-8F, 3-Phase, 4-W.ire, Wye CORPORATON RALEGH, N. C Printed in U.S.A.
5 Westinghouse.L A NSTALLATON OPERATON MANTENANCE NSTRUCTONS SWTCHBOARD WAlTHOUR METERS TYPES D2B-2F; D2B-7F AND 028-SF N FT-21 FLEXTEST CASE Fig. 7. FT-27 Case. Fig Chassis. APPLCATON CHART METER TYPE NUMBER OF STATORS CRCUT APPLCATON D2B-2 F 2 2, or 3-phose, 3 wire 3-phose, 4 wire Delta 3-phase, 4 wire Wye D2B-7 F 2 3-phase, 4 wire Delta D2B-8 F 2 3-phase, 4 wire Wye SUPERSEDES. L P F LOOP 5 ENCLOSE: \ PLASTC - -=E BEHND F=.:.v.:,::: EFFECTVE JULY 1963
6
7 "' TYPE D2B FLEXTEST SWTCHBOARD METERS -- GENERAL The meter elements are mounted on a removable chassis, which is held in the case by two latches. All connections between the case and the chassis are made through the test switches. Automatic shorting switches are provided on all current circuits to prevent opening current transformers when testing or removing the chassis. For testing, leads can be clipped to the test lugs above the chassis jaws and on the switch blades. Two test plugs are available to facilitate calibration of these meters. The 10-circuit plug is inserted into the chassis jaws and is provided with binding post terminals for connections to the test circuit. Current measurements are made by connecting ammeters to a current circuit test plug, which is then inserted into the current switch assembly, between the chassis and the case. The mounting hardware supplied with the meter permits either projection or semi-flush on panels up to 3/16" thick. For projection mounting on panels thicker than 3/16" special hardware is furnished on request. Provisions have been made on all FT-21 cases for convenient field installation of either 2 or 3 wire contact devices. Three knockouts located on the back of the case (close to the top) when removed, allow a molded insulation block, with two or three terminals and male plugs, to be fastened to the case. A bracket, with the proper number of female sockets, can be attached to the rear of the meter-frame & latch assembly in the proper position to allow the male and female parts to mate when the meter is inserted in the case. The parts are available in kit form for this application. CALl BRA Tl ON All meters are calibrated on single phase. The basic watthour constant (K h ) for these meters is.6 per nominal 600 watt rating. The single-phase test speed 16-2/3 rpm except for the D2B-8 for which it is 22-2/9 rpm. Both of these are given on a 120 volt basis. The following is a guide to watthour stator calibration. Detailed calibration procedure is available in L ADJUSTMENTS Full Load, Light Load and Balance. All of these adjustments are made at the front of the meter. The full load adjuster knob is in the center; knob the light load knob at the left and the balance at the right. Direction of adjustment is indicated by the arrow on the nameplate ("F" indicates fast). Power Factor Power factor adjustment is made by changing the resistance of the soldered loop located at the back of each electromagnet. ncreasing the resistance (lengthening the loop) increases the speed on lagging power factors. REPLACEMENT PARTS AND REPARS Where facilities are limited or where only a small number of meters are used, it is recommended that the meters be returned to the factory for repairs. When returning a meter for repairs, obtain a Returned Material Tag from the District Office so as to avoid delay in identifying the shipment. GENERAL DATA COMBNED STATORS OF 5. AMP VOLT- 60 CYCLE METERS TYPE 02B-2F D2B-8F STA RTNG WATTS WATTHOUR CONSTANT FULL LOAD R.P.M. ON SNGLE PHASE TEST (Kh) FOR TRANSFORMER BURDENS SEE THE TABLE ON PAGE /3 22-2/9
8
9 TYPE D2B FLEXTEST SWTCHBOARD METERS L_L_. _42-_20::..:..;.: A 31...:..;..:. caae type FT-21 case dimensions panel cutout dimensions terminal and ,-----f mountinghardware front view side view semi-flush projection TRANSFORMER BURDE NS FOR 60 CYCLE METERS VOLT AGE COl L Cl RCU TS, NCLUD NG P.l. LA MP. FOR RATED MULTPLES OF 120. V. E\,..-o Fig. 3. Mounting of FT-27 Case. VOL T-AMPS. WATTS POWER FACTOR CURRENT COL CRCUTS EACH STATOR 5. AMPS. ON 5. AMP. COL. VOL T-AMPS WATTS POWER FACTOR AMPS. ON 2.5 AMP. COL. EACH STATOR VOL T-AMPS z CRC WATTS POWER FACTOR CRCUT CLOSNG/ DEY CE JcuRAENT TEST JAC< L for semi-flush mounting "0-32 panel VOLTAGE TRANSFORMER CONNECTON BELOW Fig. 4. REAR VEW... Type D28-2F, 3-Phase, 3 Wire. -18 screw (for thick panel use -18 stud) screw (for thick panel use stud) NOTE: Cl RCUT CLOSNG SWTCH $ 0P RATEO 8'1' TEST SWTCH HAHOl.( a ALSO BY R WO'V4L OF CHASSS EXTEJ'U.l JUWP RS 10-"' ''i--3
10
11 TYf,a:; D2B FLEXTEST SWTCHBOARD METERS -- J!CUT OEVCE CLOSNG j'c:urr[nt TEST JACK NEUTAAL NEUT RAL Fig ,,RCUT CLOSNG DEVCE r L EXTERNAL J - VOLTAGE TRANSFORMER CONNECTON BELOW Jcl ' r -[3[7 RE AR VEW JUMPERS Type D2B-2F, 3-Phase, 4-Wire, Delta, CURRENT TEST JACK L VOLTAGE TRANSFORMER CONNECTON BELOW Fig. 7. _L cf:=:: = - REAR VEW ' J' j' NOTE CRCUT CLOSNG SWTCHES OPERATED BY TEST SWTCH HANDLE tlo ALSO BY REMOVAL Of CHASSS EXTERNAL 'J-7-5 NEUTRAL JUMPERS Type D2B-7F, 3-Phase, 4-Wire, Delta.. RCUll OEVtCE -' CURRENT TEST JACK... CRCUT CLOS!G NOTE: CRCUT CLOSNG SWTCHES OPERATED BY TEST SWTCH HANDLE 6 Al-SO BY RE.OVAL NE JTRAL VOLTAGE TRANSFORMER CONNECTON BELOW fdv---'1' :=::= - FJ7?? : NEUTRAL Fig. 6. DEVCE J CURRENT 1 JACK Cl.'JSHtG TEST REAR VEW OF CHASSS Type D2B-2F, 3-Phase, 4- Wire, Wye. r L VOLTAGE TRANSFORMER CONNECTON p + - -fc:::l =::;-::_.:: - ---' FOR 72 VOLT SER tic NOTE CACUT CLOS""'G SWTCHES OPERATED BY TEST SWTCH HANDLE 6 ALSO BY REWOVAL EXTERNAL 9-7-!1, 10-2 BELOW SZC?? === o::. NEU!ffAL Fig. 8. REAR VEW OF CHASSS JUWPERS - Type D2B-8F, 3-Phase, 4-Wire, Wye WESTNGHOUSE ELECTRC CORPORATON METER DVSON RALEGH, N. C. Printed in U.S.A
12
www. ElectricalPartManuals. com STBUCTIONS "D" LINE WATTHOUR METER CALIBRATION INFORMATION INSTALLATION OPERATION MAINTENANCE I.L
.L. 42-101.3 NSTALLATON OPERATON MANTENANCE NTRO DUCT ON This leaflet is intended to give specific instruc tions for the calibration of Westinghouse watthour meters. Part of this leaflet contains a very
More informationINSTRUCTIONS. seconds. the tween the end of the bearing screw and the. top of the shaft. The moving contact is a small silver hemisphere
. L. 41-793 NSTALLATON OPERATON MANTENANCE NSTRUCTONS TYPE CRN REVERSE POWER RELAY FOR MARNE SERVCE CAUTON Before putting relays into service remove all blocking which may have been inserted for the purpose
More informationwww. ElectricalPartManuals. com INSTRUCTIONS TYPE CO CONTACT MAKING AMMETER INSTALLATION OPERATION MAINTENANCE I.. L APPLICATION
l.. L. 41-109 NSTALLATON OPERATON MANTENANCE NSTRUCTONS TYPE CO CONTACT MAKNG AMMETER CAUTON Before putting relays into service, remove all blocking inserted for the purpose of securing the parts during
More informationINSTRUCTIONS SWITCHBOARD WATTHOUR METERS IN FT-21 FLEXITEST CASE TYPES 048-F, D48-2F, D48-3F, D48-7F, D48-8F TYPE D4B-7 F APPLI CATION CHART
NSTALLATON OPERATON MANTENANCE NSTRUCTONS SWTCHBOARD WATTHOUR METERS N FT-21 FLEXTEST CASE Westinghouse. L. 42-227 TYPES 048-F, D48-2F, D48-3F, D48-7F, D48-8F TYPE D4B-7 F APPL CATON CHART CRCUT TYPE NUMBER
More information,k''! SUPPLEMENTARY l.l INSTRUCTIONS
HVX/i.RHY SWTCHES /:1 1,k''! SUPPLEMENTARY l.l. 41-603.7 NSTRUCTONS TYPE RS RELAY FOR TONE RELAYNG TEST SWTCH CONT-'CTO SWTCHES --: 0 njtrl. f::oox1,;d Fig.l-ntemal Schematic of the Type RS Relay for Tone
More informationwww. ElectricalPartManuals. com INST UCTIONS 221 LINE SWITCHBOARD INSTRUMENTS FOUR AND ONE -HALF-INCH CLASSIFICATION 100 SCALE TYPE
Westinghouse.L. 43-22.1D NSTALLATON OPERATON MANTENANCE NST UCTONS 221 LNE SWTCHBOARD NSTRUMENTS FOUR AND ONE -HALF-NCH CLASSFCATON 100 SCALE TYPE GENERAL Type 221 instruments are designed and built to
More informationSIEMENS. Current-Limiting Fuses. DESCRIPTION ceo '1 I. 2.4 and 4.8 Kv for Motor Starting Application. Type FM. Page 1 EFFECTIVE FEB..
j SEMENS DESCRPTON CurrentLimiting Fuses 2.4 and 4.8 Kv for Motor Starting Application The fuse (Fig. ) is a totallyenclosed currentlimiting fuse, designed for motorstarting applications. t is available
More informationwww. ElectricalPartManuals. com :li)w"o!i oc: INSTRUCTIONS TYPE HLF LOSS OF FIELD RELAY INSTALLATION OPERATION MAINTENANCE \7-1'lt) I.L
:li)w"o!i oc: ( en.l. 41-746. la NSTALLATON OPERATON MANTENANCE \7-1lt) NSTRUCTONS * --- --- --- --- --- --- --- --- --- --- --- --- --- --- --- --- --- --- --- --- --- --- --- --- --- --- --- --- ---
More informationNo-barrier design Self-extinguishing materials Front-connected, back-connected and flush-mounted styles Blades operate independently or can be ganged together Recognized by UL and cul STATES Type have
More informationINSTRUCTIONS GEK AUTOMATIC RECLOSING RELAY. www. ElectricalPartManuals. com. GENERAL fj ELECTRIC
NSTRUCTONS AUTOMATC RECLOSNG RELAY TYPE NSR21G GENERAL fj ELECTRC 8 CONTENTS DESCRPTON. 3 APPLCATON. 3 GENERAL CONSDERATONS. 3 RATNGS. 4 CHARACTERSTCS. 4 OPERATNG PRNCPLES. 5 BURDENS. 5 CONSTRUCTON 5 RECEVNG,
More informationType MTS Miniature Test Switches
Type MTS Miniature Test Switches o o o o Compact and versatile Front- and back-connected styles Safe, durable, rugged and reliable Recognized by CUL & UL DESCRIPTION In many panelboard, switchgear, metering,
More information3.0 CHARACTERISTICS E Type CO-4 Step-Time Overcurrent Relay
41-106E Type CO-4 Step-Time Overcurrent Relay A core screw accessible from the top of the switch provides the adjustable pickup range. The IIT contacts are connected in the trip circuit to trip instantaneously.
More informationTABLE OF CONTENTS. Description Page Description Page. SETI Finland. Approvals:
3 ulletin 100 IEC Contactors ulletin 100 15 Sizes, 9 600 Guarded Terminals Dual Terminal Markings DC Control Option through 180 Wide Range of ccessories Top and Side Mounting uxiliary Contacts Timers Latches
More informationHigh barriers Recognized by UL and cul Self-extinguishing materials Nonferrous material Corrosion-resistant nickel finish Safety-grip handle A complete line of switches is available for meter, relay, instrument,
More informationMaster Connection Diagram Series C R-Frame Circuit Breaker with DIGITRIP RMS Trip Units
nstruction Leaflet L29C714L Supersedes L 29C714K Dated 01/12 Circuit Breaker with DGTRP RMS Trip Units nstruction Leaflet L29C714L Circuit Breaker with DGTRP RMS Trip Units LNE 1 2 3 NDEX DAGRAMS TRP UNT
More informationwww. ElectricalPartManuals. com I N S T R V C T I 0.N S TYPE BL-1 THERMAL OVERLOAD RELAY Westinghouse I.L INSTALLATION OPERATION MAINTENANCE
CAUTON Westinghouse.L 41-553.1 NSTALLATON OPERATON MANTENANCE N S T R V C T.N S TYPE BL-1 THERMAL OVERLOAD RELAY Before putting relays into service, remove all blocking which may have been inserted for
More informationwww. ElectricalPartManuals. com INSTRUCTIONS TYPE COQ NEGATIVE SEQUENCE GENERATOR RELAY Westinghouse I.L G INSTALLATION OPERATION MAINTENANCE
CAUT ON Westinghouse.L. 41-161G NSTALLATON OPERATON MANTENANCE NSTRUCTONS TYPE COQ NEGATVE SEQUENCE GENERATOR RELAY Before putting protection relays into service, remove all blocking hich may have been
More informationTerminal strip and backer plate for terminating voltage inputs Kit for mounting VT Pack on outside of existing cabinet or socket
Product Index 2900 Sencore Drive, Suite 100 Sioux Falls, SD 57107 VT Packs 6004824: 2:1 VT Pack for use on any 480V service requiring three VTs. A6004824-2: 2:1 VT Pack for use on 480 volt 3-wire delta
More informationSpaceStation TM. Installation Instructions SpaceStation Occupancy Lighting Control System. Please Save These Instructions
Phone: 605.542.4444 concealte.com! Installaton SpaceStaton Occupancy Lghtng Control System Please Save These Important Safeguards Read and Follow All Safety þdo not use outdoors. þdo not let power supply
More informationCON EDISON EQUIPMENT
CON EDISON EQUIPMENT Con Ed Navtech Size Volts Amps List Spec. Cat. No Description Price 205 N-205 10x10x5 100 $72.00 205 RTN-205 10x10x5 100 190.00 215 N-215 24x12x8 200 144.00 215 RTN-215 24x12x8 200
More informationA - Add New Information C - Change Existing Information D - Delete Information. Page 7. Delete the fourth paragraph beginning CAUTION
ABB Effective: November 1990 This Addendum Supersedes all Previous Addenda Addendum to Instruction Leaflet 41-137.3H Type KRD-4 Directional Overcurrent Ground Relay A - Add New Information C - Change Existing
More informationTA Ta VA CTRL-XFRMR
3804 South Street 7964-7263, TX Nacogdoches Phone: 936-69-7941 Fax: 936-60-468 TA2437 Ta-2-437 10VA CTRL-XFRMR Acme Electric Catalog Number TA2437 Manufacturer Acme Electric Description Control Transformer,
More informationwww. ElectricalPartManuals. com Instructions for Type CVR-1 Voltage Regulating Relay Westinghouse Electric Corporation
nstructions for Type CVR-1 Voltage Regulating Relay Westinghouse Electric Corporation Power Transformer Division, Sharon, Pa..B. 47-065-9A Elfecci,-e NoYember, 1962 Supersedes.B 47-065-9, March, 1961 Page
More informationIllustrated Parts List for GPU-400
Illustrated Parts List for GPU-400 Series 500082-4xx 28.5 Volts, 400 Amps Section 1 Illustrated Parts List 1) Explanation of Parts List Arrangement The parts list is arranged so that the illustration will
More informationIndustrial Control Transformers
6 Industrial Control Transformers Section 6 Industrial Control Transformers provide a low and safe control voltage for the operation of electromagnetic devices, such as motor starters, contactors, solenoids
More informationBBC. Renewal Parts. I-T-E Low-Voltage Power Circuit Breakers
BBC BROWN BOVERI RP 6..2.8-2C Renewal Parts I-T-E Low-Voltage Power Circuit Breakers Type K-000, 4000, 0008, and 40008 Stationary and Drawout Mounted 000 and 4000 Amperes 600 Volts RP 6..2.8-2 Page 2 Table
More informationClassic Update Series
J Clamps Two J-Clamps have been provided to retain the Cluster Kit Wiring in place (see photographs on pages 7 and ). Remove the original J-Clamps from the Cluster and replace with the two J-Clamps item
More informationTECHNICAL MANUAL OPERATOR S ORGANIZATIONAL SIRECT SUPPORT AND GENERAL SUPPORT MAINTENANCE MANUAL METER TEST SETS TS-682/GSM-1 AND TS-682A/GSM-1
TECHNICAL MANUAL OPERATOR S ORGANIZATIONAL SIRECT SUPPORT AND GENERAL SUPPORT MAINTENANCE MANUAL METER TEST SETS TS-682/GSM-1 AND TS-682A/GSM-1 (NSN 6625-00-669-0747) This copy is a reprint which includes
More informationAccessories. Accessories. Meter Mounting Equipment
Covers & Sealing Rings..................................................................... 119 AW & H-Base Hubs.......................................................................... 119 Flush Trim
More informationABB. Type CRQ Directional Negative Sequence Relay for Ground Protection B 1.0 APPLICATION 2.0 CONSTRUCTION AND OPERATION CAUTION
ABB Instruction Leaflet 41-163.2B Effective: January 1977 Supersedes I.L. 41-137.3A, Dated September 1974 ( ) Denotes Change Since Previous Issue Type CRQ Directional Negative Sequence Relay for Ground
More informationwww. ElectricalPartManuals. com INSTRUCTIONS TYPES RW AND RW-2 DEMAND REGISTERS BLOCK INTERVAL TYPE Westinghouse INSTALLATION OPERATION MAINTENANCE
/ 0.5 "' / / General Westinghouse.L. 42-31SE NSTALLATON OPERATON MANTENANCE NSTRUCTONS TYPES RW AND RW-2 DEMAND REGSTERS 10 Wcsr h \\, U OUsc \. 4.0_.. 4.5. ' Fig. 1- Type RW- Demand Register. NTRO DUCT
More informationUse Littlites anywhere you need a little light! Gooseneck Lamps & Accessories
Use Littlites anywhere you need a little light! Gooseneck Lamps & Accessories THE FLEXIBLE GOOSENECK LAMP WITH VERSATILITY AND STYLE. AMPSETS High Intensity Low Intensity L-3/12 L-4/18 Detachable Gooseneck
More informationthe systems people Owners Manual VCMS Switch Panel System Model VCMS-SP34
Owners Manual VCMS Switch Panel System Model VCMS-SP34 1. Product Description The Switch Panel System consists of a eight-position switch module, two six-output power modules and a 10 ft. communications
More informationPage 2 DS LOW VOLTAGE POWER CIRCUIT BREAKERS Digitrip Trip Unit Inside Wiring Guide Outside Wiring Guide Shutter Drawout Unit Position Indicator Escut
Page 1 Supersedes Renewal Parts Data 33-790-1G pages 1-20 dated December, 1988 Mailed to: C, D, E/33-700 Westinghouse DS and DSL Low Voltage Power Circuit Breakers and Cell Parts Contents Pages DS Breaker
More informationPOWER BREAK Circuit Breakers
r - i f l, i.,.. -.... i." nstructions GEH-4693 POWER BREAK Circuit Breakers 800-2000 Frames 240-600 Vac NTRODUCTON The POWER BREAK line of insulated case circuit breakers are designed to protect low-voltage
More informationwww. ElectricalPartManuals. com INSTRUCTIONS TYPE HQS PHASE SELECTOR RELAY FOR INSTALLATION OPERATION MAINTENANCE APPLICATION
I. L. 41-610.2 INSTALLATION OPERATION MAINTENANCE INSTRUCTIONS TYPE HQS PHASE SELECTOR RELAY FOR TYPE HKB SINGLE-POLE CAUTION Before putting relays into service, remove all blocking which may have been
More informationGroup Meter Main - Without Bypass
100 Amp Vertical 2012 MS60 (closed) 2012 MS60 (open) Application For vertical multi-meter/mains installations - 6 position maximum 225A and 400A main buss Main breaker provisions - breakers not included
More information~... INS_TR_UC_TI_ON_P_AM_PH_LE_T _U-5_81_6 --~ GENERAL PURPOSE ELECTRONIC WHEEL DETECTOR INSTALLATION AND MAINTENANCE (UN ) CONTENTS ...
WABCC... NS_TR_UC_T_ON_P_AM_PH_LE_T _U-5_81_6 -- GENERAL PURPOSE ELECTRONC WHEEL DETECTOR NSTALLATON AND MANTENANCE (UN451062-0801) CONTENTS General.... Operating Characteristics nstallation Procedure
More informationENGINE GOVERNING SYSTEMS LSM672 LOAD SHARING MODULE. GOVERNORS AMERICA CORP. 720 Silver Street Agawam, MA , USA MEMBER
ENGINE GOVERNING SYSTEMS LSM672 LOAD SHARING MODULE MEMBER GOVERNORS AMERICA CORP. 720 Silver Street Agawam, MA 01001-2907, USA LSM672 LOAD SHARING MODULE PRODUCT TECHNICAL INFORMATION PTI 4000 AUGUST
More informationCT Metering. CT Metering. Meter Mounting Equipment
Single Meter Sockets, Without Bypass - CT Rated.................................. 67-68 Single Meter Sockets, CT Rated With Test Switch Bypass Provision............. 69-70 Meter Socket / Enclosure Combination
More informationType SJK Test Switches
Type SJK Test Switches No-barrier design Self-extinguishing materials Front-connected, back-connected and flush-mounted styles Blades operate independently or can be ganged together DESCRIPTION STATES
More informationData Bulletin. Ground-Censor Ground-Fault Protection System Type GC Class 931
Data Bulletin 0931DB0101 July 2001 Cedar Rapids, IA, USA Ground-Censor Ground-Fault Protection System Type GC Class 931 09313063 GT Sensor Shunt Trip of Circuit Interrupter Window Area for Conductors GC
More informationELECTRO-MECH SCOREBOARD CO.
ELECTRO-MECH SCOREBOARD CO. MM-338 FOOTBALL SCOREBOARD OWNER S HANDBOOK Thank you for choosing an Electro-Mech Scoreboard for your athletic complex. We are confident that your new scoreboard will give
More informationMultiple Metering, Horizontal Gang - Non Lever Bypass
Multiple Metering, Horizontal Gang - Non Bypass 100 Amp & 200 Amp Continuous per Position - 600 VAC Application 2-6 meter position Designed for watt hour meters that meet ANSI C12.10 Overhead or underground
More informationFORM NO. HSC-543 AIR HANDLERS
FORM NO. HSC- AIR HANDLERS AH10X1 High Efficiency featuring New Industry Standard R-10A Refrigerant Features AH10X1 features the new X-1 (ECM) motor which provides enhanced SEER performance with most Sure
More informationINSTRUCTIONS. S&c Circuit-Switchers - Mark v Grounding Switches - 70,000 Amperes Momentary Outdoor Transmission I INTRODUCTION INSTRUCTION SHEET 7 1 1
S&c Circuit-Switchers - Mark v Grounding Switches - 70,000 Amperes Momentary With 90-degree opening blades NSTRUCTONS - - - - - - - - - - - - - - For Field Assembly and nstallation NTRODUCTON CAUTON: The
More informationElectronic Proportional (EP) Control for Medium Duty Piston Pumps
Electronic Proportional (EP) Control for Medium Duty 72400 Piston Pumps EP Control for Medium Duty 72400 Piston Pumps Table of Contents Introduction........................................................................
More informationINSTRUCTIONS FOR REMOVAL OF GROUND FAULT PROTECTION DEVICE FROM HOBART GENERATOR SETS SPECIFICATION NUMBER
TO-161 073085 INSTRUCTIONS FOR REMOVAL OF GROUND FAULT PROTECTION DEVICE FROM HOBART GENERATOR SETS SPECIFICATION NUMBER 6184-3..-.-.._. HOBART BROTHERS COMPANY Power Systems Division Troy, Ohio 45373
More informationTABLE I 60 CYCLE BURDEN OF THE CVD RELAY AT CONTINUOUS RATING
the voltage unit contacts, this effect is negligible. 3.2 Trip Circuit The main contacts will close 30 amperes at 250 volts dc and the seal-in contacts of the indicating contactor switch (ICS) will carry
More informationAGRICULTURAL UNDERGROUND SERVICE 500 HP OR LESS
Prepared by: ABB1 AGRICULTURAL UNDERGROUND SERVICE 500 HP OR LESS 05619 Asset Type: Electric Metering Function: Design and Construction Issued by: Lisseth Villareal (LDV2) Date: 07-31-15 Rev. #10: This
More informationB CW POWER RELAY
41-241.31B CW POWER RELAY nected in such a way that current, (I A ), leads voltage, (V BA ), by 150 degrees when the motor is operating at unity power factor. Loss of excitation to the motor causes a large
More informationTEKMEC TEKMEC ABSOLUTE CONTROL PUSH BUTTON STATIONS PUSH BUTTON STATIONS - IN FRP & CAST ALUMINIUM ENCLOSURE STANDARD TAILOR MADE EC TI M I T ME PCMS
ABSOLUTE CONTROL RF M EC TI NT PE CO TEKMEC TEKMEC ON TM TM M I T ME PCMS M11104IN (AN ISO 9001:008 CERTIFIED COMPANY) S - IN FRP & CAST ALUMINIUM ENCLOSURE STANDARD TAILOR MADE S SCOPE & SPECIFICATION
More informationwww. ElectricalPartManuals. com INSTRUCTIONS TYPE KLF-1 LOSS-OF-FIELD RELAY Westinghouse INSTALLATION OPERATION MAINTENANCE LL
CAUTON Before putting protective relays into service, Westinghouse LL. 41-7 48.1 s NSTALLATON OPERATON MANTENANCE NSTRUCTONS TYPE KLF-1 LOSS-OF-FELD RELAY remove all blocking which may have been inserted
More informationType IMC Indoor current transformer
Instrument transformers Type IMC Indoor current transformer Product features 600 volt indoor 10 kv BIL 25 through 400 Hertz amperes: 50-1000 2.5" (64 mm) round window Designed for variable applications
More informationAn ISO 9001 Company. BOP 1KW-MG FIRMWARE RETROFIT KIT
INSTRUCTION MANUAL 1. DESCRIPTION KEPCO An ISO 9001 Company. BOP 1KW-MG FIRMWARE RETROFIT KIT BOP 1KW-MG RETROFIT KIT 219-0562 Kepco KIT 219-0562 contains the PROMs used to upgrade the firmware for BOP
More informationINSTRUCTION MANUAL HIGH-VOLTAGE VACUUM CONTACTORS MOTOR& TRANSFORMER APPLICATION. May, 2001 TOSHIBA CORPORATION SOCIAL INFRASTRUCTURE SYSTEM COMPANY
TOSHBA NSTRUCTON MANUAL HGH-VOLTAGE VACUUM CONTACTORS MOTOR& TRANSFORMER APPLCATON TYPE:CV-10HA TYPE:CV-1 OHAL 12/15kV-400A-5/4kA 12/15kV-400A- 5/4kA May, 2001 REV. 4 TOSHBA CORPORATON SOCAL NFRASTRUCTURE
More informationASSEMBLING THE 15 INCH FLUSH MOUNT TOUCH SCREEN DIMENSIONS OF THE 15 INCH FLUSH MOUNT TOUCH SCREEN
DIMENSIONS OF THE 15 INCH FLUSH MOUNT TOUCH SCREEN 18 (457 mm) 12 39/64 (320 mm) 3 1/2 (89 mm) 1 13/32 (36 mm) 19 (483 mm) 3 5/8 (92 mm) 7/64 3 mm) 1 13/32 (36 mm) 23 53/64 (605 mm) 20 3/4 (527 mm) 12
More informationwww. ElectricalPartManuals. com (fr} lite Imperial Carporatian ''- METAL-ENCLOSED, FUSED-INTERRUPTER SWITCH INSTRUCTIONS
METAL-ENCLOSED, FUSED-NTERRUPTER SWTCH NSTRUCTONS STANDARD MANUAL OPERATNG MECHANSM The -T-E interrupter swit ch operating me chanism is a st ored-energy device. This st ored-energy device operat es independently
More informationElectronic Proportional (EP) Control for Heavy Duty Series 2 Piston Pumps Model 33
Electronic Proportional (EP) Control for Heavy Duty Series 2 Piston Pumps Model 33 Model 39 Model 46 Model 54 Model 64 EP Control for Heavy Duty Series 2 Piston Pumps Table of Contents Introduction........................................................................
More informationCamaro Camaro
Important facts about this kit. 1. The dash panel used in this picture is used by permission of Covan's Classic. We Make Wiring Easy! 2. This kit requires some modification to your original under dash
More informationSmart Switch Basic Kit - 24 volt ( ) Wiring Instructions
Smart Switch Basic Kit - 4 volt (54-08) Wiring Instructions NB 8/0/ 6 ga. wire 6 ga. wire 6 ga. wire OUT IN 6 ga. wire Yellow Black Blue 50 AMP BREAKER MOTOR 6 ga. wire 6 ga. wire 6 ga. wire ROCKER SWITCH
More informationINSTRUCTIONS GEH-1789B GEH-1789A SUPERSEDES BALANCED-CURRENT RELAYS. Types. IJCSlB IJCSlC IJC53A. www. ElectricalPartManuals. com. GENERAL f) ELECTRIC
NSTRUCTONS GEH-1789B SUPERSEDES BALANCED-CURRENT RELAYS Types JCSlB JCSlC JC53A GENERAL f) ELECTRC GEH-1789A Balanced-Current Relays Type JC 3 5? - 6 J 1\JUMBE!NG OF STUDS (FRONT VEW) 7 5-\t--z:r-i rz%._,
More informationElectrical devices may only be mounted and connected by electrically skilled persons.
Art. No. : 1711DE Operatng nstructons 1 Safety nstructons Electrcal devces may only be mounted and connected by electrcally sklled persons. Serous njures, fre or property damage possble. Please read and
More informationwww. ElectricalPartManuals. com GENERAL. ELECTRIC RENEWAL PARTS METAL-CLAD SWITCHGEAR TYPES M-26 AND M-36 GEF-4351C Supersedes GEF-4351B
Data subject to change without notice. RENEWAL PARTS METAL-CLAD SWTCHGEAR TYPES M-26 AND M-36 ORDERNG NSTRUCTONS 1. Always specify the complete nameplate data of the equipment. GEF-4351C Supersedes GEF-4351B
More informationANSI Switchboard Meters
ANSI Switchboard Meters High quality range of switchboard instruments with Class 1 accuracy and which complies with American ANSI-C39.1 (1981) specifications. Available in 4 1 /2" case size, the rugged
More informationwww. ElectricalPartManuals. com MAGNETIC TIME RELAYS GENERAL. ELECTRIC INSTRUCTIONS *IC *Also identified with prefix CR instead of IC.
NSTRUCTONS MAGNETC TME RELAYS *C2820-054 *Also identified with prefix CR instead of C. GENERAL. ELECTRC GEH-85F NTRODUCTON The CR2820-054 relay is a d-e operated relay. t may be applied as an instantaneous
More informationwww. ElectricalPartManuals. com INSTRUCTIONS MAINTENANCE OPERATION DESCRIPTION TYPE TRO THERMAL RELAY With Thel'mal Load Indicating Dial
.L. 46-728-7 DESCRPTON OPERATON MANTENANCE NSTRUCTONS FG.. Front Vie of TRO Relay. TYPE TRO THERMAL RELAY is used on poer transformers of all types as a combination overload protective device and thermal
More informationELECTRICAL. The following pages include the various electrical wiring d iagrams of all the 1970 and '71 Ski-Doo Snowmobile vehicles.
3-02-01 ELECTRCAL 3-2 ELECTRCAL CHARTS (A) GENERAL The folloing pages include the various electrical iring d iagras of all the 1970 and '71 Ski-Doo Snoobile vehicles. MPORTANT t is iportant to reeber that
More information34.00 METERING GENERAL LABELING MULTIPLE METER ENCLOSURES ON A SINGLE PREMISE
4. METERING GENERAL LABELING MULTIPLE METER ENCLOSURES ON A SINGLE PREMISE 4.-4 4. SELF-CONTAINED METERING, SINGE-PHASE INSTALLATION DETAILS /4 VOLT SINGLE-PHASE UNDERGROUND RESIDENTIAL SERVICE AND METER
More informationTYPICAL LUMATIC HUMIDIFIER (Figure A)
NSTALLATON, OPERATON AND MANTENANCE NSTRUCTONS LUMATC HUMDFER CARNES COMPANY, VERONA, WSCONSN TYPCAL LUMATC HUMDFER ( A) Steam Distributor Pipes (9) Fused Disconnect or Circuit Breaker (6) Ground Terminal
More informationApproved Meter Sockets and Cabinets
Single Unit Residential Guide 1 PHASE, 120/240 VOLT SERVICES SERVICE CAPACITY OWNED METERING (Metering sockets and cabinets are supplied by Customer). Outdoor meter mounting height is 1730 mm ( 5 8 ) to
More informationMCO HALF SIZE MODELS (electric) MCO-E-5 FROM 2000 AND UP
MCO HALF SIZE MODELS (electric) MCO-E-5 FROM 2000 AND UP Toll Free Phone, (US & Canada): (800) 427-6668 Toll Free Fax, (US & Canada): (800) 36-7745 http://www.garland-group.com FORM # MCO E5 Elec (Rev
More informationClass 320 Metering. Class 320 Metering. Meter Mounting Equipment
Single Meter Sockets, Without ypass -............................ 57-58 Meter Mains, With Optional MCC ypass -......................... 59-60 Meter Main Load Centers, With Optional MCC ypass -..........
More informationWestinghouse Electric Corporation Distribution Apparatus Division Bloomington, Indiana Indoor-Outdoor Altitude 0-10,000 feet KV
May 975 Supersedes 8-2 F WE A, Pages -2, dated January 975 E, D, C/98 /DB Dimensions, Weights and Creep These notes apply to all ratings.. These arresters are designed for 0,000 feet. ncrease clearances
More informationMP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION. MP Meter-Pak Meter Centers
Product Description PRODUCT DESCRIPTION MPH66125 with Horn Bypass Square D brand MP Meter-Pak meter centers from Schneider Electric offer a wide range of solutions for multi-metering applications: UL Listed
More information201 S. Anaheim Blvd. Page No Anaheim, CA RULE NO. 2 DESCRIPTION OF SERVICE
201 S. Anaheim Blvd. Page No. 3.2.1 A. GENERAL 1. The character of electric service available at any particular location should be ascertained by inquiry at the City's Electrical Engineering Division office.
More informationINSTRUCTION BOOK. INDUCTION.t. VOLTAGE REGULATORS. Types Slud STI. www. ElectricalPartManuals. com Westinghouse Electric Corporation-
-c NSTRUCTON BOOK NDUCTON.t. VOLTAGE REGULATORS Types Slud ST ------Westinghouse Electric Corporation- LB. 47 310-Z --- PECAL NQURE--- When communicating with Westinghouse regarding the product covered
More informationELECTRICAL PRODUCTS. ISO/TS Registered
ISO/TS 16949 Registered Burglar Alarm For 6, 12 and 24 Volts Die Cast Stainless Steel Scalp, 2 Keys, Threaded Full Length Antifreeze Lubricant in Lock Dimmer DS2903 Dimmer Switch Replaces: GM 1997028,
More informationMODEL 422 Submersible Pump Controller
MODEL 422 Submersible Pump Controller Monitors True Motor Power (volts x current x power factor) Detects Motor Overload or Underload Operates on 120 or 240VAC, Single-phase or 3-phase Built-in Trip and
More informationTOPAZ 12 WALL PACK INSTALLATION & MAINTENANCE GUIDE (Part # LIT A)
TOPAZ 12 WALL PACK INSTALLATION & MAINTENANCE GUIDE (Part # LIT-29499-1A) Contractor: Please read these instructions before starting installation. After installation, please forward this guide to the user
More informationRENEWAL PARTS AK-2-15 AK-2-25 AK-3-25 AKF-2-25 AK-2A-15 AK-2A-25 AK-3A-25 AKF-2A-25 AKU-2-25 AKU-3-25 AKU-2A-25 AKU-3A-25
Data ubject to change without notice. RENEWAL PARTS POWER CIRCUIT BREAKERS TYPES 225 AMP FRAME SIZE 00 AMP FRAME SIZE GEF-449G Supersedes GEF-449F AK-2-5 AK-2-25 AK-3-25 AKF-2-25 AK-2A-5 AK-2A-25 AK-3A-25
More informationGE 8000-Line Motor Control Centers
GE 8000-Line -1 ENCLOSURE TYPES TYPE 1 General Purpose, Indoor Intended for use indoors, primarily to prevent accidental contact of personnel with the enclosed equipment, in areas where unusual service
More informationABB ! CAUTION. Type KRV Directional Overcurrent Relay E 1.0 APPLICATION 2.0 CONSTRUCTION AND OPERATION. Instruction Leaflet
ABB Instruction Leaflet 41-137.2E Effective: February 1994 Supersedes I.L. 41-137.2D, Dated February 1973 ( )Denotes Change Since Previous Issue. Type KRV Directional Before putting relays into service,
More information651 SERIES POWER CONTROL UNITS Single Phase, Phase Angle SCR Controller
651 SERIES POWER CONTROL UNITS Single Phase, Phase ngle SCR Controller STNDRD FETURES Electronic design utilizing Large Scale Integration. Phase lock loop for firing pulse synchronization. Standard ratings
More informationPARTS LIST FOR LN-25 LN-25
P-374 P-374 PARTS LIST FOR 200 250 300 350 400 450 500 550 600 650 700 100 150 50 IN IN/MIN WIRE FEED MORE T13086-99 1. 5. 4. 3. 2. IN/MIN. USED. cross. 35 31 23 25 27 29 15 17 19 21 P-374-A P-374-A ILLUSTRATION
More informationTEMPORARY ELECTRIC WIRING FOR CARNIVALS, CONVENTIONS, EXHIBITIONS, FAIRS AND SIMILAR USES
INFORMATION BULLETIN / PUBLIC - ELECTRICAL CODE REFERENCE NO.: LAMC 93.0230 Effective: 3-24-69 DOCUMENT NO. P/EC 2002-006 Revised: 11-17-00 Previously Issued As: RGA #7-69 TEMPORARY ELECTRIC WIRING FOR
More informationPower Switching Devices
Watlow has manufactured solid state power controllers for over forty years. Watlow s is a microprocessor-based product that features application flexibility unmatched by any other silicon controlled rectifier
More informationSERVICE ENTRANCE - UNDERGROUND Single & Three Phase 200, & 320/400 Amp
Printed from NIPSCO.com 04-01-17 PAGE 1 OF 6 USE: Arrangement of service equipment to supply electric energy to an underground, outdoor self contained meter installation. LATEST REVISION: PREVIOUS REVISION
More information29048, 29049, 29050, 29051, 29052, 20953, 29054,
July 15, 2008 Lit. No. 29225, Rev. 06 29048, 29049, 29050, 29051, 29052, 20953, 29054, 29400-2 HARNESS KIT 3-PORT ISOLATION MODULE LIGHT SYSTEM w/2-plug SYSTEM HARNESSES Installation Instructions Read
More informationKS , KS I KS , AND KS EMERGENCY LIGHTING RELAY SWITCHES REQUIREMENTS AND ADJUSTING PROCEDURES
BELL SYSTEM PRACTCES AT & TCo Standard ssue 4, November 1979 KS-5 1 89, KS-5189-0 1 KS-5189-02, AND KS-5189-03 EMERGENCY LGHTNG RELAY SWTCHES REQUREMENTS AND ADJUSTNG PROCEDURES 1. GENERAL 2. REQUREMENTS
More informationMichigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE
PAGE 261116-1 SECTION 261116 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,
More information2.0 CONSTRUCTION AND OPERATION 3.0 CHARACTERISTICS K. CO (HI-LO) Overcurrent Relay
41-100K 2.0 CONSTRUCTION AND OPERATION The type CO relays consist of an overcurrent unit (CO), either an Indicating Switch (ICS) or an ac Auxiliary Switch (ACS) and an Indicating Instantaneous Trip unit
More informationwww. ElectricalPartManuals. com INSTRUCTIONS NO LOAD TAP CHANGER TYPE WSB-4 INSTALLATION OPERATION MAINTENANCE
I. L. 46-720-5 INSTALLATION OPERATION MAINTENANCE INSTRUCTIONS FIG. 1. Operating Mechanism and Position Indicator THE TYPE WSB-4 TAP CHANGER provides an adequate and convenient method for changing transformer
More informationPOWER AMPLIFIER SERVICE MANUAL CONTENTS
POWER AMPLIFIER CONTENTS Performance Specifications... 2 Notes... 2 Rear Panel... 3 Section Location... 3 Block Diagram... 4 Interconnection Diagram... 5-8 Multi-channel Schematic and PCB... 9 Heatsink
More informationINSTRUCTION PAMPHLET NUMBER U-6702
- NSTRUCTON PAMPHLET NUMBER U-6702 UNON SWTCH & SGNAL SWSSVALE, PA. DVSON OF WESTNGHOUSE AR BRAKE COMPANY CHRONOGRAPH ******************** TABLE OF CONTENTS Page Description................................
More informationAdjustable Torque Controls
MCS0 Adjustable Torque Control The MCS0 is an enclosed control complete with a cover and mounting provisions. A brake and clutch may be operated separately with this control or up to four units, two at
More informationPAMPBLIT NUMBER U- 8474
NSTRUCTON PAMPBLT NUMBER U- 8474 UNON SWTC:B a SGNAi. SWVJU, Pa. DVSON or WESTNGHOUSE AR BRAKE COMPANY,t :1,1 f l ' STYLE CDD THREE POSTON CODE FOLLOWNG RELAY Catalog Plate W-23 ******************* TABLE
More informationMeter Mains - Without Bypass
- 100 & 200 Amp Application Single meter position Receive ANSI C12.10 watthour meters Surface or flush mount (see chart) 1M1R (closed) U2M2R (open) Construction Ring type NEMA Type 3R ANSI 61 gray E-coat
More informationRECESSED TRACK (120V) SPECIFICATIONS
RECESSED TRACK (120V) SPECIFICATIONS GENERAL Recessed track shall be approved by the NEC for flush-mounting into ceiling or any flat surface. Recessed Track shall allow fixtures to be easily focused, switched,
More informationCATALOG OF REPLACEMENT PARTS
CATALOG OF REPLACEMENT PARTS ELECTRIC CONVECTION OVENS DEC5 HEC5 HEC5D HEC5X HEC5DX ML-126749 ML-126750 ML-126751 ML-126753 ML-126754 A product of HOBART 701 S. RIDGE AVENUE TROY, OHIO 45374-0001 FORM
More information