Westinghouse Electric Corporation Distribution Apparatus Division Bloomington, Indiana Indoor-Outdoor Altitude 0-10,000 feet KV

Size: px
Start display at page:

Download "Westinghouse Electric Corporation Distribution Apparatus Division Bloomington, Indiana Indoor-Outdoor Altitude 0-10,000 feet KV"

Transcription

1 May 975 Supersedes 8-2 F WE A, Pages -2, dated January 975 E, D, C/98 /DB Dimensions, Weights and Creep These notes apply to all ratings.. These arresters are designed for 0,000 feet. ncrease clearances "S" and 'T' % for each 000 feet over 000 feet. 2. When installed, exhaust ports should be directed away from adjacent apparatus. s above 2 KV do not have directional venting.. Arrester assembly consists of arrester unit, line terminal casting, ground terminal bracket, grading ring (if required), all hardware (excluding base mounting hardware), master nameplate, and line and ground connectors. 4. Add.00 inches to "" dimension when using an insulating post. Add.00 inches to "" dimension when using an insulating base. 5. Line a.d ground clamp type connectors suitable for copper or aluminum conductors with diameter of 0.25 to 0.75 inches. Detaii " A " Distribution Apparatus Division Bloomington, ndiana 4740 ndoor-outdoor Altitude 0-0,000 feet KV Single Unit Poles Style No. 5040A02A4 5040A0A 5040A04A8 89A0A0 89A07A2 89A09A0 89A09A 89A0A8 89A2A0 89AA2 89A4A4 89AA8 89A8A0 89A9A2 KV (j) See 0 nstallation Layout, Page 2. For Brown Porcelain contact Westinghouse. Q) Grading Ring not used below 8 Kv rating. 8-2 F WE A Dimension Sheet Page Station Arrester CPL Controlled Protective Level Dimensions (nches), D dia@ RQ) S T(j) Creep Weight (Lbs) Fig

2 Page 2 Two Unit Poles Figure Dimensions (nches) Style No. Dimensions (nches) Ratmg, 2, 89 A2 2A82 89 A2 4A02 89 A2 5A82 89A2A42 89A27A2 89 A2 8A82 89 A OA02 89AA22 Kv Distribution Apparatus Division Bloomington, ndiana > Figure 4. nsulating Post Grounded Termnal May be Mounted -.. Under any Bolt, ' A'..75 ±-- / w J " A '.75 X 0 ndustry Standard Threads.75 Deep Tapped oles (Each End) Section "A-A" 20 (TypiCal).50 Diameter Bolt Circle Brown-S# 897A95A0 Gray - S# 898A95A0 Mounting Dimensions ( Phase nstallation Layout) ' Bottom 0 ArresterU nt Mountng oles for.750 Dameter Bolts Figure 5. nsulating Base Mountmg oles for.750 Dameter Bolts.50 Diameter Bolt C rcle Brown-S# 897A945A0 Gray - S# 898A945A0 Mountng ole for.750 Dameter Bolts ;_?-f-.l..'--'-...,. :...:...4-v (Thickness of Lug on Castng.00) Detail A s-radus Exhaust Vent Ports D Dia R s T p:reep Weight (Lbs.) Fig Detail B Mounting oles for.750 Dameter Bolts

3 Cl z Figure Style See Enlarged View 'A , Rati n_ g 89A9A2 89A42A02 89A44A42 89A4A82 Dimensions in nches - - K v --- Weight Min l_l-i hts_ _ Mounting Dimensions ( Phase nstallation Layout) Mounting ole for.750 Diameter ( ) ----':,.S,{-->-,.7\ Bolts Equally Spaced on Diameter Bolt Circle (Casting Lug,875 Thick) View ' A '.52 Diameter--==t:t=;tj) -f-+*- ( ) oles.25 Thick (Reference Term mal) Further nformation Price List 8-0 Descriptive Bulletin 8- Design Test Report File 8-4 Performance Data 8- nstruction Leaflet 8- - Blitzwatcher Monitoring Device PL 8-0 and DB 8-0 _ Clearances Grading Rings 8-2 F WE A Dimension Sheet Page ':_bs : Creep,, :::_, -s---=_tt=- D, =- [)2_ fr 2500 i i " T ---+foo----t -- orizontal Limit for Grounded Objects/ D R D4 R4 Fig

4 8-2 F WE A Dimension Sheet Page 4 Distribution Apparatus Division Bloomington, ndiana 4740 Cl

5 Westinghouse Dimensions, Weights and Creep These notes apply to all ratings Figure. These arresters are designed for 0,000 feet increase clearances "S" and 'T' % for each 000 feet over 000 feet. 2. When installed, exhaust ports should be directed away from adjacent apparatus.. Arrester assembly consists of arrester unit, line terminal casting, ground terminal bracket, grading ring (if required), all hardware (excluding base mounting hardware), master nameplate, and line and ground double eyebolt connectors. 4. Add.00 inches to " '' dimension when using an insulating post. Add.00 inches to " " dimension when using an insulating base. 5. Line and ground double eyebolt connectors suitable for copper or aluminum conductors with diameter of 0.25 to 0.75 inches. Dimensions (nches) Style No. Gray 898A00A0 898A072A0 898A090A0 898A09A0 898A 08A0 898A 20A0 898A 2A0 898A 44A0 Style Gray 898A 8A0 898A 80A0 898A 92A0 Kv Kv <D See 0 nstallation Layout For Brown Porcelain contact Westinghouse See Enlarged Vew Of Terminoi-Detoil-:ti Do/A.. ffi._, : R Dimension Sheet 8-2 Page Station Arrester CPL Controlled Protective Level ndoor-outdoor Altitude 0-0,000 feet 0-2 KV Figure 2 Moster Nome Plate "' Min. Creep nches See Enlarged View Of Terminal-Detoii'A Min. Creep nches May, 972 New nformation E, 0, C/98 /DB ffi._, : Net Weight (Lbs ) Net Weight (Lbs ) Fig. Fig

6 Dimension Sheet 8-2 Page 2 Station Arrester CPL Controlled Protective Level ndoor-outdoor Altitude 0-0,000 feet 0-2 KV Fig. See Enlarged View Of Terminal- Detail 'A,.. Dimensions (nches) Style Gray Kv 898A204A02 898A2A02 898A228A02 898A240A02 898A258A02 898A24A02 898A27A02 898A288A02 898A00A02 898A2A <D For Brown Porcelain contact Westinghouse.8.8 Fig. 4 nsulating Post Distribution Apparatus Division, Bloomington, nd Printed in USA.75 x 0 ndustry Std. Thds. 75 Deep Tapped ate (Each End) Brown S B97A95AO Gray S B9BA95A0 Stet. A-A Mtg. ole For.750 ' '\. Dia.Bolts,Thickness Of Lug On Casting = nches Bolt Circle s Fig.5 nsulating Base Ground Termmol Min Creep nches T --- -o t--- T----il"'i orizontal Limit For Grounded Objects e nstallation Layout Further nformation: Brown 5 897A945AO G oy S 898A945A0 NetWt (Lbs.) Fig Price List 8-0 Descriptive Bulletin 8- Design Test Report File 8-4 Performance Data 8- nstruction Leaflet 8--2 Blitzwatcher Monitoring Device PL 8-0 and DB 8-0

Westinghouse Electric Corporation Distribution Apparatus Division Bloomington, Indiana Indoor-Outdoor Altitude 0-1 0,000 feet KV

Westinghouse Electric Corporation Distribution Apparatus Division Bloomington, Indiana Indoor-Outdoor Altitude 0-1 0,000 feet KV December 1975 New nformation and Supersedes 38-132 F WE A, Pages 1-, dated May 1975, and DS 38-122, pages 1-2, dated December, 1973 E, D, C/1981/DB Dimensions, Weights and Creep These notes apply to all

More information

www. ElectricalPartManuals. com CPL Station Arrester Controlled Protective Level Page 1 Indoor-Outdoor Altitude 0-10,000 feet KV

www. ElectricalPartManuals. com CPL Station Arrester Controlled Protective Level Page 1 Indoor-Outdoor Altitude 0-10,000 feet KV December, 1975 New nformation and Supersedes DB 38-131 Pages 1-4, dated May 1972, and 38-121 D WE A, Pages 1-4, dated April1974 E, D, C/1981/ DB Westinghouse Electric Corporation Distribution Apparatus

More information

www. ElectricalPartManuals. com It'll Cutler-Hammer WLI Medium Voltage Switchgear Renewal Parts Renewal Parts Data Page 1

www. ElectricalPartManuals. com It'll Cutler-Hammer WLI Medium Voltage Switchgear Renewal Parts Renewal Parts Data Page 1 t'll Cutler-Hammer Supersedes Renewal Parts Data, pages 1-2, dated June 1992 Renewal Parts Data Page 1 WL Medium Voltage Switchgear Renewal Parts Renewal Parts Data Page 2 WL Medium Voltage Switchgear

More information

Indoor or Outdoor 2400 to 14,400 Volts 600 to 14,400 Kvac, 3 Phase, 60 Hz

Indoor or Outdoor 2400 to 14,400 Volts 600 to 14,400 Kvac, 3 Phase, 60 Hz c February, 1979 Supersedes DB 39-485, pages 1-4, dated November, 1973 Mailed to: E, D, C/2001, 2002/DB Benefits There are many capacitor applications in which factors such as physical location, personnel

More information

Westinghouse Electric Corporation Distribution Apparatus Division Bloomington, Indiana 47401

Westinghouse Electric Corporation Distribution Apparatus Division Bloomington, Indiana 47401 February 26, 1976 Supersedes PL 38-640 dated October 15,1974 Pages 1-8 Prices effective April 29, 1974 Subject to change without notice Selling Policy 38-000 Mailed to E, D, C/1991, 2430/ PL Standard Bill

More information

PSC Terminations. Features Class 1 (outdoor) termination as defined in IEEE 48 standard. For use on all extruded dielectric cables.

PSC Terminations. Features Class 1 (outdoor) termination as defined in IEEE 48 standard. For use on all extruded dielectric cables. Features Class 1 (outdoor) termination as defined in IEEE 48 standard. For use on all extruded dielectric cables. Sizes are available for all shielded cables in voltage classes from 15kV through 46kV.

More information

WLI Medium Voltage Switchgear Renewal Parts

WLI Medium Voltage Switchgear Renewal Parts Page 1 Supersedes Renewal Parts Data, pages 1-2, dated June 1992, WLI Medium Voltage Switchgear Renewal Parts Page 2 Standard Manually Operated Fused WLI Switch ➇ ➁ ➀ ➂➃ WLI Switch Mechanism ➉ ➈ m Replacement

More information

STEEL. P ole P roducts

STEEL. P ole P roducts STEEL P ole P roducts Value. Durability. Safety. SSS A Mounting Height Square Straight Steel Pole No Arm Removable Pole Cap (Tenon Option Available - See Mounting Designation) D Top Square B Wall Gauge

More information

VariSTAR Type AZE station-class surge arresters for systems through 345 kv IEEE certified

VariSTAR Type AZE station-class surge arresters for systems through 345 kv IEEE certified Surge s Catalog Data CA235022EN Supersedes TD235009EN September 2014 COOPER POWER SERIES VariSTAR Type AZE station-class surge arresters for systems through 345 kv IEEE certified General Eaton s Cooper

More information

Kuhlman Electric Corporation Volt Instrument Transformers

Kuhlman Electric Corporation Volt Instrument Transformers Kuhlman Electric Corporation 46000 Volt Instrument Transformers 46000 Volt Table of Contents Description Model Page Wound, Dry-Type VT (High Accuracy available) U/VRU-52(H) 3-4 Wound, Oil-Filled VT (High

More information

1E EJB Junction Boxes Cl. I, Div. 1 and 2, Groups B, C, D

1E EJB Junction Boxes Cl. I, Div. 1 and 2, Groups B, C, D Cl. I, Div. and 2, Groups B, C, D Cl. II, Div., Groups E, F, G Cl. II, Div. 2, Groups F, G Cl. III NEMA 3, 4, 4*,, Ex d IIB + H2 T, IP Explosionproof Dust-Ignitionproof Raintight Wet Locations Applications:

More information

UltraSIL polymer-insulated and porcelain loadbreak Type LB open distribution cutout

UltraSIL polymer-insulated and porcelain loadbreak Type LB open distribution cutout Fusing Equipment Catalog Data CA132035EN Supersedes November 2015 COOPER POWER SERIES UltraSIL polymer-insulated and porcelain loadbreak Type LB open distribution cutout Description Eaton has set a standard

More information

GENERAL. CONSTRUCTION External

GENERAL. CONSTRUCTION External Surge Arresters VariSTAR Type AZG4 Surge Arresters for Systems through 400 kv IEC 20-kA; Line Discharge Class 4 Electrical Apparatus I235-84 GENERAL VariSTAR AZG4 Surge Arresters incorporate the latest

More information

Instrument Transformer Reference. Meter and Relay Applications for the Electrical Industry

Instrument Transformer Reference. Meter and Relay Applications for the Electrical Industry Instrument Transformer Reference Meter and Relay Applications for the Electrical Industry Note: For Current and Voltage Transformer Pricing Information refer to: 600 V -PL 42-800 5 kv-36 kv -PL 42-900

More information

www. ElectricalPartManuals. com SPECIFICATIONS Page 1 of 24 March 24, 2003

www. ElectricalPartManuals. com SPECIFICATIONS Page 1 of 24 March 24, 2003 Types SM-4, SM-5, SMD-20, and SMD-40 Outdoor Distribution (4.16 kv through kv) Conditions of Sale STANDARD: Seller s standard conditions of sale set forth in Price Sheet apply, except as modified under

More information

Features and Application

Features and Application ML-DTL- Features and Application MS2426*/AE66* Features and Application ML-DTL- family offers connectors with bayonet coupling as well as threaded coupling. These connectors are intermateable with correspondingly

More information

Specifications. S&C Power Fuses Types SM- 4, SM-5, SMD-20, and SMD-40 Outdoor Distribution (4.16 kv through 34.5 kv)

Specifications. S&C Power Fuses Types SM- 4, SM-5, SMD-20, and SMD-40 Outdoor Distribution (4.16 kv through 34.5 kv) S&C Power Fuses Types SM- 4, SM-5, SMD-0, and SMD-40 Outdoor Distribution (4.16 kv through kv) For use with SM Refill Units or SMU Fuse Units Specifications Conditions of Sale STANDARD: The seller s standard

More information

Kuhlman Electric Corporation Volt Instrument Transformers

Kuhlman Electric Corporation Volt Instrument Transformers Kuhlman Electric Corporation 34500 Volt Instrument Transformers 34500 Volt Table of Contents Description Model Page Wound, Dry-Type VT Y (High Accuracy available) PTT-200-9710(H) 3-4 Wound, Oil-Filled

More information

www. ElectricalPartManuals. com WeSTinghouse Secondary Unit Substation Transformers (Power Centers) Descriptive Bulletin Page 1

www. ElectricalPartManuals. com WeSTinghouse Secondary Unit Substation Transformers (Power Centers) Descriptive Bulletin Page 1 WeSTinghouse Descriptive Bulletin 47-156 Page 1 liquid Filled, Self-Contained 112% 2500 Kva June, 1974 Supersedes DB 47-350, dated August 1972 E, D, C/2082/DB Descriptive Bulletin 47-156 Page 2 Westinghouse

More information

Type HS PEXLIM-P Surge Arresters Maximum System Voltage 123 kv to 800 kv

Type HS PEXLIM-P Surge Arresters Maximum System Voltage 123 kv to 800 kv Type HS PEXLIM-P Surge Arresters Maximum System Voltage 123 kv to 800 kv HS PEXLIM-P Metal Oxide Surge Arrester HS PEXLIM-P Surge Arresters are used for the protection of switchgear, transformers and other

More information

Type IMC Indoor current transformer

Type IMC Indoor current transformer Instrument transformers Type IMC Indoor current transformer Product features 600 volt indoor 10 kv BIL 25 through 400 Hertz amperes: 50-1000 2.5" (64 mm) round window Designed for variable applications

More information

sirco-ul_004_b_cat 100A to 2000A - 600VDC and 1000VDC UL98B Listed

sirco-ul_004_b_cat 100A to 2000A - 600VDC and 1000VDC UL98B Listed site_317_a sirco-ul_22_b_cat sirco-ul_4_b_cat 1A to 2A - 6VDC and 1VDC UL98B Listed  Function non fusible disconnects are heavy duty switches that break and make 6VDC or 1VDC photovoltaic circuits on

More information

SUBSTATION BUS-SUPPORT FITTINGS

SUBSTATION BUS-SUPPORT FITTINGS SUBSTATON BUSSUPPORT FTTNGS EHV ALUMNUM BUSSUPPORT FTTNGS FOR ALUMNUM TUBNG PCTORAL NDEX SUBJECT AUP Clamp (Bolted) or Slide 5inch Bolt Circle WAUPDR Fixed (Weld) or Slide 5inch Bolt Circle Double Ring

More information

www. ElectricalPartManuals. com Instructions for Cast Resin Bushing, 15 KV & Below

www. ElectricalPartManuals. com Instructions for Cast Resin Bushing, 15 KV & Below Instructions for Cast Resin Bushing, 15 KV & Below Fig. 1 Cast Resin Bushing The Westinghouse Cast Resin Bushing, used for voltages 15KV and below, is made by casting an insulating resin around the conductor.

More information

M-Force three-phase switch

M-Force three-phase switch Switches and Disconnects CA008004EN Supersedes May 2015 COOPER POWER SERIES M-Force three-phase switch Description Eaton's Cooper Power series M-Force switch is a distribution-class, gang-operated, factory

More information

Westinghouse Electric Corporation Distribution and Control Business Unit Assemblies Division Bloomington, Indiana

Westinghouse Electric Corporation Distribution and Control Business Unit Assemblies Division Bloomington, Indiana Supersedes Descriptive Bulletin, pages 1-8, dated January, 1976 Mailed to: E, D, C/38-000F Westinghouse Electric Corporation Distribution and Control Business Unit Assemblies Division Bloomington, Indiana

More information

www. ElectricalPartManuals. com INSTRUCTIONS "INERTEEN AND OIL INSULATED FEEDER SWITCHES DESCRIPTION INSTALLATION MAINTENANCE

www. ElectricalPartManuals. com INSTRUCTIONS INERTEEN AND OIL INSULATED FEEDER SWITCHES DESCRIPTION INSTALLATION MAINTENANCE r \ FIG. 1. Cutaway View of Typical Switch. I.L. 46-723-1 DESCRIPTION INSTALLATION MAINTENANCE INSTRUCTIONS THE INERTEEN AND OIL INSULATED FEEDER SWITCH provides complete switching facilities in a minimum

More information

1-3/4" MOUNTING INSTRUCTIONS: 1150 SERIES SURFACE MOUNTED 1500 LB. ELECTROMAGNETIC LOCK

1-3/4 MOUNTING INSTRUCTIONS: 1150 SERIES SURFACE MOUNTED 1500 LB. ELECTROMAGNETIC LOCK MOUNTING INSTRUCTIONS: 1150 SERIES SURFACE MOUNTED 1500 LB. ELECTROMAGNETIC LOCK FULL WIDTH STOP WITH SURFACE MOUNT ARMATURE Model Numbers: 1150, 1152 & 1155 READ THOROUGHLY BEFORE INSTALLING HEADER STOP

More information

Bulletin 1494V Variable Depth Flange-Mounted Disconnect Switches. Bulletin 1494F Fixed-Depth Flange-Mounted Disconnect Switches

Bulletin 1494V Variable Depth Flange-Mounted Disconnect Switches. Bulletin 1494F Fixed-Depth Flange-Mounted Disconnect Switches 2 Bulletin 1494 NEMA Disconnect Switches Section Overview Bulletin 1494V Variable Depth Flange-Mounted Disconnect Switches Open Type, Fusible 30 600 A Open Type, Non-Fusible 30 600 A Page 2-3 Bulletin

More information

ZHENGZHOU ORIENT POWER CO., LTD

ZHENGZHOU ORIENT POWER CO., LTD PORCELAIN INSULATORS Hollow bushings: The porcelain bushings are used extensively in electrical apparatus. Porcelain bushing is the device that enables one or several conductors to pass through a partition

More information

distribution transformers. Single-Phase Overhead GENERAL. Cooper Power Systems manufactures a complete line of single-phase overhead-type

distribution transformers. Single-Phase Overhead GENERAL. Cooper Power Systems manufactures a complete line of single-phase overhead-type Distribution Transformers Single-Phase Overhead Electrical pparatus 0-0 GENERL ooper Power Systems manufactures a complete line of single-phase overhead-type distribution transformers. Single-phase transformers

More information

Single phase pole mounted. 11kV. Electrical Engineer KEU ID#:

Single phase pole mounted. 11kV. Electrical Engineer KEU ID#: Single phase pole mounted Distribution Transformers 11kV Prepared by: ARY SAIDAHMED SHEKSAEED Electrical Engineer KEU ID#: 4252 Email: ary.sayd@hotmail.com 1 S # Contents Page # 1 Introduction 3 2 Type

More information

Bulletin 1494D Fixed-Depth Flange-Mounted Circuit Breakers

Bulletin 1494D Fixed-Depth Flange-Mounted Circuit Breakers Bulletin 1494D Fixed-Depth Flange-Mounted Circuit Breakers Bulletin 1494D Fixed Depth Flange Mounted Circuit Breaker Operating Mechanism Industrial rated circuit breaker operating mechansim pre-assembled

More information

M-Force three-phase switch

M-Force three-phase switch Supersedes K-SEC 926 December 2012 M-Force three-phase switch Description The M-Force switch from Eaton's Cooper Power Systems is a distribution-class, gangoperated, factory unitized three-phase overhead

More information

25 kv Apparatus Bushings

25 kv Apparatus Bushings Page 1 2001 ELRIM Cycloaliphatic Epoxy Provides: Nontracking, self-scouring, nonweathering performance Superior dielectric strength, dielectric loss and power factor Choice of shapes allows design innovation

More information

Condenser Bushings. OIL-TO-AIR - Oil-Impregnated Paper ANSI STANDARDS IEEE C AND IEEE C AN ALSTOM COMPANY

Condenser Bushings. OIL-TO-AIR - Oil-Impregnated Paper ANSI STANDARDS IEEE C AND IEEE C AN ALSTOM COMPANY PAO Condenser Bushings - kv BUSHINGS OI-TO-AIR - Oil-Impregnated Paper ANSI STANDARDS IEEE C.9.0-000 AND IEEE C.9.0-99 AN ASTOM COMPANY PAO bushings are capacitance-graded bushings with an oil-impregnated

More information

35-kV 200-kV BIL Apparatus Bushings B Series (bolt-in) for Elbow to Air-Insulated Service 200 Amp, 600 Amp, 900 Amp and 1250 Amp

35-kV 200-kV BIL Apparatus Bushings B Series (bolt-in) for Elbow to Air-Insulated Service 200 Amp, 600 Amp, 900 Amp and 1250 Amp Page 1 2018 Grounded Metal Equipment Plate Equipment Connection 35 kv Separable Insulated Connector (elbow) Bus Bar or Other Component Grounded Metal Equipment Plate Equipment Connection Bus Bar or Other

More information

25-kV Apparatus Bushings B Series (bolt-in) for Elbow to Air-Insulated Service 200 Amp, 600 Amp, 900 Amp and 1250 Amp

25-kV Apparatus Bushings B Series (bolt-in) for Elbow to Air-Insulated Service 200 Amp, 600 Amp, 900 Amp and 1250 Amp Page 1 2018 Grounded Metal Equipment Plate Equipment Connection Bus Bar or Other Component 15 kv or 25 kv Separable Insulated Connector (elbow) Equipment Connection Power Cable Power Cable ELRIM Cycloaliphatic

More information

TYPE BILT DISCONNECT SWITCHES

TYPE BILT DISCONNECT SWITCHES TYPE BILT DISCONNECT SWITCHES OUTDOOR HOOKSTICK OPERTED (DISTRIBUTION CLSS) For sectionalizing and tap applications 7.5KV through 38KV 900 -- 40,000 momentary Furnished with hooks for loadbreak tool Used

More information

www. ElectricalPartManuals. com Substation Transformers Primary or Secondary Open

www. ElectricalPartManuals. com Substation Transformers Primary or Secondary Open Substation Transformers Primary or Secondary Open GENERAL Cooper Power Systems Primary or Secondary Open Substation Transformers are designed to meet exact customer specifications. Flexibility in design,

More information

Premium Efficiency Exceeds Effciency Levels Mandated by CSA C390 and EPACT 92

Premium Efficiency Exceeds Effciency Levels Mandated by CSA C390 and EPACT 92 Premium Efficiency Exceeds Effciency Levels Mandated by CSA C390 and EPACT 9 Crown Triton TM Series Premium Efficiency Motors Experience Combined with Technology yundai Induction Motors use Finite Element

More information

Bulletin 1494V Variable-Depth Flange-Mounted Circuit Breaker Operating Mechanism

Bulletin 1494V Variable-Depth Flange-Mounted Circuit Breaker Operating Mechanism Bulletin V Variable-Depth Flange-Mounted Circuit Breakers Product Overview/Product Selection Circuit Breaker Kits Cat. No. V-C Circuit Breaker Kit (Shown without handle and connecting rod) Bulletin V Variable-Depth

More information

Features and Application

Features and Application ML-DTL-83723 Series Features and Application Bayonet and Threaded Coupling Features and Application ML-DTL-83723 Series family offers connectors with bayonet and threaded coupling including lanyard-release

More information

Technical Specification for Pole Mounted Capacitor Rack

Technical Specification for Pole Mounted Capacitor Rack Technical Specification for Pole Mounted Rack Page 1 1. Scope and Function a) Pole mounted capacitor racks shall be installed on a distribution feed as an economical means of applying capacitor units to

More information

35-kV Safefront SuperWell Mini-Switch Source Isolated Pad-Mounted Switchgear 50 Amp (Max) Clip-Mounted Current Limiting Fuses

35-kV Safefront SuperWell Mini-Switch Source Isolated Pad-Mounted Switchgear 50 Amp (Max) Clip-Mounted Current Limiting Fuses Page 1 2016 EPMR-35-311S-R2/ESW-CM9 Three Phase Two Ways per Phase 200 Amp 35 kv Class Eaton s CPS LRTPs 50 Amp (Max) 27 kv Clip-Mounted NX Fuse Provisions 21.1/36.6 kv Grounded Wye Max Design, 150 kv

More information

35-kV Apparatus Bushings B Series (bolt-in) for Elbow to Air-Insulated Service 200 Amp, 600 Amp, 900 Amp and 1250 Amp

35-kV Apparatus Bushings B Series (bolt-in) for Elbow to Air-Insulated Service 200 Amp, 600 Amp, 900 Amp and 1250 Amp Page 1 2018 Grounded Metal Equipment Plate Equipment Connection Bus Bar or Other Component 35 kv Separable Insulated Connector (elbow) Grounded Metal Equipment Plate Equipment Connection Bus Bar or Other

More information

Each of these factors, as they apply to the selection of Types CLE and CLS current limiting fuses, is briefly outlined on the following pages.

Each of these factors, as they apply to the selection of Types CLE and CLS current limiting fuses, is briefly outlined on the following pages. Westinghouse n This Application Data Description Page Table Fig. No. No. General information... 1 Description......... 1 Let-through current.... 3 A 1,2 Threshold current... 3 A 2 Ratings, voltage and

More information

Type POLIM-S Surge Arresters Maximum System Voltage 2.52 to 245 kv

Type POLIM-S Surge Arresters Maximum System Voltage 2.52 to 245 kv Type POLIM-S Surge Arresters Maximum System Voltage 2.52 to 245 kv POLIM-S Metal Oxide Gapless Surge Arresters POLIM-S Surge Arresters are used for the protection of switchgear, transformers and other

More information

Catalog Number. Notes

Catalog Number. Notes Catalog Number FEATURES & SPECIFICATIONS INTENDED USE Round Tapered Aluminum Pole with Single or Twin s is a special purpose light pole to provide up to 40-foot mounting heights for Roadway lighting applications.

More information

Westinghouse Molded Case Circuit Breakers Engine Generator FG Amperes

Westinghouse Molded Case Circuit Breakers Engine Generator FG Amperes Circuit s FG 15-150 Amperes Description Page Type FG Three-Pole... 1 Type JG Three-Pole... 3 Type KG Three-Pole... 5 Type G Three-Pole... 7 Type MG Three-Pole... 9 Type NG Three-Pole... 11 Cutler-Hammer

More information

www. ElectricalPartManuals. com Substation Transformers Primary or Secondary Unit

www. ElectricalPartManuals. com Substation Transformers Primary or Secondary Unit Substation Transformers Primary or Secondary Unit GENERAL Cooper Power Systems Primary or Secondary Unit Substation Transformers are designed to meet exact customer specifications. Flexibility in design,

More information

Catalog 14A January 2013

Catalog 14A January 2013 Catalog 14A January 2013 Page 1 January 2013 Type AR (Automation-Ready) Switch 14.4kV, 25kV or 34.5kV 900 Amperes Continuous/Interrupt Description The Hubbell unitized Type AR switch is a distribution-level,

More information

UltraSIL polymer-housed VariSTAR station-class surge arresters

UltraSIL polymer-housed VariSTAR station-class surge arresters Surge s Catalog Data CA235013EN Supersedes August 2015 COOPER POWER SERIES UltraSIL polymer-housed VariSTAR station-class surge arresters General Eaton has set a new standard of excellence for polymer-housed

More information

Surge arresters. UltraSIl Polymer-Housed VariSTar Type UI Intermediate-Class Surge arresters. General. COnSTrUCTIOn

Surge arresters. UltraSIl Polymer-Housed VariSTar Type UI Intermediate-Class Surge arresters. General. COnSTrUCTIOn Surge arresters UltraSIl Polymer-Housed VariSTar Type UI Intermediate-Class Surge arresters electrical apparatus 235-75 General Cooper Power Systems has set a new standard of excellence for polymerhoused

More information

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS SECTION 26 28 16 ENCLOSED SWITCHES AND PART 1 - GENERAL 1.1 SUMMARY A. Section includes the following individually mounted, enclosed switches and circuit breakers rated 600V AC and less: 1. Fusible switches.

More information

JACKSON ENERGY AUTHORITY ELECTRIC SERVICE POLICY EFFECTIVE SEPTEMBER 26 th, 2005 *REVISED JULY 12 th, 2017

JACKSON ENERGY AUTHORITY ELECTRIC SERVICE POLICY EFFECTIVE SEPTEMBER 26 th, 2005 *REVISED JULY 12 th, 2017 JACKSON ENERGY AUTHORITY ELECTRIC SERVICE POLICY EFFECTIVE SEPTEMBER 26 th, 2005 *REVISED JULY 12 th, 2017 JEA SHALL MAKE ALL METER SPOTS BEFORE ELECTRICAL WORK BEGINS AS TO DETERMINE THE POINT OF ATTACHMENT

More information

VAREC 5810B/5820B Series. Relief Valve and Flame Arrester

VAREC 5810B/5820B Series. Relief Valve and Flame Arrester VAREC 0B/0B Series The 0B/0B Series is a combination of the 00B/00B Series and Relief Valve and the 000 Series Flame Arrester. INTRODUCTION The VAREC 0B/0B Series Relief Valve and Flame Arrester is a combination

More information

15-kV Live Terminal 600 Amp Group Operated Pad-Mounted Metal-Enclosed Outdoor Switchgear 140 Amp (Max) Clip Mount Current-Limiting Fuses

15-kV Live Terminal 600 Amp Group Operated Pad-Mounted Metal-Enclosed Outdoor Switchgear 140 Amp (Max) Clip Mount Current-Limiting Fuses Page 1 2015 Heavy duty 11-gauge steel enclosure is all-welded construction for long life Corrosion proof nameplate is located to provide easy access for the operator Glass reinforced barriers meet NEMA

More information

Hubbell has a policy of continuous product improvement. Please visit hubbellpowersystems.com to confirm current design specifications.

Hubbell has a policy of continuous product improvement. Please visit hubbellpowersystems.com to confirm current design specifications. Line Post Sensors Product Instruction Manual Hubbell has a policy of continuous product improvement. Please visit hubbellpowersystems.com to confirm current design specifications. 2018 Hubbell Incorporated

More information

Type ICX Outdoor open type cutout

Type ICX Outdoor open type cutout Distribution cutouts Type IC Outdoor open type cutout Product features 7.8 kv, 15 kv, 15/27 kv, 27 kv, or 38 kv on 100 A 7.8 kv, 15 kv, and 15/27 kv only on 200 A 110, 125, 150, 170, or 180 kv BIL 180

More information

A Summary of Major Improvements to the ABB Recloser and Type R Breaker

A Summary of Major Improvements to the ABB Recloser and Type R Breaker A Summary of Major Improvements to the ABB Recloser and Type R Breaker Table of Contents Introduction....................................................................3 Center Bumper..................................................................4

More information

Specifications. S&C Omni-Rupter Switches Outdoor Distribution (14.4 kv and 25 kv) Conditions of Sale

Specifications. S&C Omni-Rupter Switches Outdoor Distribution (14.4 kv and 25 kv) Conditions of Sale S&C Omni-Rupter Switches Outdoor istribution (14.4 kv and 5 kv) Specifications Conditions of Sale STNR: Seller s standard conditions of sale as set forth in Price Sheet apply. SPECIL TO THIS PROUCT: INCLUSIONS:

More information

Maximum submersible power cable length (max. cable length in feet - starter to motor)

Maximum submersible power cable length (max. cable length in feet - starter to motor) Cable sizing charts V and 0 V, ph V ph 0 V ph 0. 0. 0 (40) 00 (0) 0 (68) 00 0 (9) 90. (8) 0 (46) 0 (7) - 0 (64) 60 (49) 880 (68) (98) 480 (46) 0 90 (8) 0* (4*) 7. 40 (04) 90 (44) 00 () () 60 (9) 480 (46)

More information

Products & Services EQ Series AC Drives. TEAMMaster WOUND ROTOR MOTORS WORLD SERIES SYNCHRONOUS MOTORS. EXPLOSION PROOF (Division 1, Zone 1)

Products & Services EQ Series AC Drives. TEAMMaster WOUND ROTOR MOTORS WORLD SERIES SYNCHRONOUS MOTORS. EXPLOSION PROOF (Division 1, Zone 1) 630-543-7867 Products & Services EQ7 1-1000 hp Intelligent Keypad with Extensive Diagnostics Select Any of 4 Control Methods - V/ Hz - Dynamic Torque - Sensorless Vector - Closed-loop Vector Quick Setup

More information

Circuit Breaker Accessories BREQS125 BRHDK125

Circuit Breaker Accessories BREQS125 BRHDK125 anuary 2008 Loadcenters & ircuit reakers Type R Loadcenters & ircuit reakers ircuit reaker ccessories -75 ircuit reaker ccessories TS LW2 RLW2 RQS25 TOW (nstalled) MPL (nstalled) RQLW LW RK25 RML Table

More information

MP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION. MP Meter-Pak Meter Centers

MP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION. MP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION MPH66125 with Horn Bypass Square D brand MP Meter-Pak meter centers from Schneider Electric offer a wide range of solutions for multi-metering applications: UL Listed

More information

BRACKETS, MOUNTS & HARDWARE

BRACKETS, MOUNTS & HARDWARE HIGH VOLTAGE SWITCHGEAR & AUTOMATION EQUIPMENT SECTION 6 Brackets, Mounts & Misc. Hardware CAT. NO: 040930G May, 2008 INERTIA Engineering & Machine Works, INC. Fax: (209) 931-8186 6665 Hardaway Road, Stockton,

More information

CLEAVELAND / PRICE INC. Type RL-C Side Break Switch kv A. Bulletin DB-104E12

CLEAVELAND / PRICE INC. Type RL-C Side Break Switch kv A. Bulletin DB-104E12 Bulletin DB-104E12 Type RL-C Side Break Switch 7.2-69 kv 600-2000 A. CLEAVELAND / PRICE INC. 14000 Rt. 993, Trafford, PA 15085 (724) 864-4177 FAX (724) 864-9040 Email: sales@cleavelandprice.com Type RL-C

More information

TYPE BLT DISCONNECT SWITCHES

TYPE BLT DISCONNECT SWITCHES TYPE BLT DISCONNECT SWITCHES OUTDOOR-HOOK OPERATED 8.3KV through 38KV A & A Current Furnished with hooks for loadbreak tool REA/RUS approved S M C O 1 BLT PARALLEL BLADE DISTRIBUTION CLASS DISCONNECT SWITCH

More information

I Surge Arresters. UltraSIL Polymer-Housed VariSTAR Type U3 Surge Arrester for Systems through 275 kv IEC 10 ka; Line Discharge Class 3 GENERAL

I Surge Arresters. UltraSIL Polymer-Housed VariSTAR Type U3 Surge Arrester for Systems through 275 kv IEC 10 ka; Line Discharge Class 3 GENERAL Surge Arresters UltraSIL Polymer-Housed VariSTAR Type U3 Surge Arrester for Systems through 275 kv IEC 10 ka; Line Discharge Class 3 Electrical Apparatus I235-93 GENERAL UltraSIL Polymer-Housed VariSTAR

More information

Surge Arresters. UltraSIL Housed VariSTAR Station Class Surge Arresters GENERAL CONSTRUCTION

Surge Arresters. UltraSIL Housed VariSTAR Station Class Surge Arresters GENERAL CONSTRUCTION Surge Arresters UltraSIL Housed VariSTAR Station Class Surge Arresters Electrical Apparatus 235-88 GENERAL Cooper Power Systems has set a new standard of excellence for polymerhoused station class surge

More information

MATERIAL STANDARD ELECTRIC OPERATIONS ORGANIZATION. ****Supercedes BECo Standard E and ComElectric Spec ****

MATERIAL STANDARD ELECTRIC OPERATIONS ORGANIZATION. ****Supercedes BECo Standard E and ComElectric Spec **** Page 1 of 8 ****Supercedes BECo Standard E2.12-2.14 and ComElectric Spec 7-0895**** THREE-PHASE DEADFRONT PAD-MOUNTED DISTRIBUTION TRANSFORMERS, LOOP & RADIAL FEED DESIGNS 1.0 General Requirements 1.1

More information

15-kV Wall-Mount Switchgear Three-Phase Indoor/Outdoor 600 Amp S&C Mini-Rupter Switch

15-kV Wall-Mount Switchgear Three-Phase Indoor/Outdoor 600 Amp S&C Mini-Rupter Switch Page 1 2015 Kinked roof prevents standing moisture Glass reinforced barriers meet NEMA GPO-3 Standards 0.625" diameter copper ground bar Elliott air-insulated bushings accept IEEE Standard inserts and

More information

1ZSE en, Rev. 7. Transformer bushings, type GOB Technical guide

1ZSE en, Rev. 7. Transformer bushings, type GOB Technical guide 1ZSE 2750-102 en, Rev. 7 Transformer bushings, type GOB Technical guide This Technical Guide has been produced to allow transformer manufacturers, and their designers and engineers, access to all the technical

More information

DAQO Technical Differences of Isolated Phase Bus Standards. Study of Design Standard Variances, Insulator Design and Shipping Section Design

DAQO Technical Differences of Isolated Phase Bus Standards. Study of Design Standard Variances, Insulator Design and Shipping Section Design DAQO Technical Differences of Isolated Phase Bus Standards Study of Design Standard Variances, Insulator Design and Shipping Section Design Global Reference Medium Voltage Electrical Equipment Standards

More information

CABINET - CURRENT TRANSFORMER Indoor - Outdoor 240 Volts Amperes Maximum

CABINET - CURRENT TRANSFORMER Indoor - Outdoor 240 Volts Amperes Maximum PAGE 1 OF 5 USE: 1. For commercial and industrial installations purchased and installed by the Customer. 2. For use on the following services: 1 phase 3 wire 240 volts, 3 phase 3 wire 240 volts, 3 phase

More information

www. ElectricalPartManuals. com r" n;;-==- Westinghouse Ventilated Dry Type Transpac Power Centers Page 1 Descriptive Bulletin

www. ElectricalPartManuals. com r n;;-==- Westinghouse Ventilated Dry Type Transpac Power Centers Page 1 Descriptive Bulletin Westinghouse Application Transpac power centers are for applications where space availability is critical and thus the power center must be put into special locations such as against the wall, in closets.

More information

Surge Arresters. UltraSIL Polymer-Housed VariSTAR Surge Arresters: Normal-Duty (5 ka), Heavy-Duty (10 ka), and Heavy-Duty Riser Pole (10 ka)

Surge Arresters. UltraSIL Polymer-Housed VariSTAR Surge Arresters: Normal-Duty (5 ka), Heavy-Duty (10 ka), and Heavy-Duty Riser Pole (10 ka) Surge s UltraSIL Polymer-Housed VariSTAR Surge s: Normal-Duty (5 ka), Heavy-Duty (10 ka), and Heavy-Duty Riser Pole (10 ka) Electrical Apparatus 235-35 General Cooper Power Systems has set the standard

More information

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles P Arktite Heavy Duty Circuit Breaking Plugs and Receptacles Industrial Heavy Duty Non-hazardous Areas Applications: Arktite circuit breaking plugs and receptacles are used: To supply power to portable

More information

Single-Phase Step Voltage Regulator

Single-Phase Step Voltage Regulator Single-Phase Step Voltage Regulator - Overhead Mounted - Page 1 of 12 Table of Contents 1 GENERAL... 3 2 CONSTRUCTION... 3 3 RIV REQUIREMENT... 7 4 REGULATOR CONTROLS... 7 5 TESTS... 9 6 EVALUATION...

More information

Approved Meter Sockets and Cabinets

Approved Meter Sockets and Cabinets Single Unit Residential Guide 1 PHASE, 120/240 VOLT SERVICES SERVICE CAPACITY OWNED METERING (Metering sockets and cabinets are supplied by Customer). Outdoor meter mounting height is 1730 mm ( 5 8 ) to

More information

Installation Instructions LINK---C

Installation Instructions LINK---C IS---LINK---C Page 1 of 10 Installation Instructions LINK---C DEADBREAK CAM LINK OPERABLE CONNECTOR SYSTEM The is a 600 amp, connector designed to: 1.) provide a fully shielded, fully submersible hot stick

More information

BUSSMANN. 8.3kV E-Rated SERIES. Medium voltage fuses for feeder circuit, switchgear and transformer. protection. Technical Data 10352

BUSSMANN. 8.3kV E-Rated SERIES. Medium voltage fuses for feeder circuit, switchgear and transformer. protection. Technical Data 10352 8.3kV E-Rated Description: E-Rated, current-limiting, medium voltage fuses for feeder circuit, switchgear and transformer protection. Supersedes pril 2015 USSMNN SERIES Medium voltage fuses for feeder

More information

Bulletin 1494F Fixed-Depth Flange-Mounted Disconnect Switches. Selection Guide

Bulletin 1494F Fixed-Depth Flange-Mounted Disconnect Switches. Selection Guide F Fixed-Depth Flange-Mounted Disconnect Switches Selection Guide F Fixed-Depth Flange-Mounted Disconnect Switches Product Cat. No. 1494F-N Disconnect Switch with Cat. No. 1494F-F Fuse Block Adapter Plate

More information

dfdf 34.5 kv and 69 kv, Type O Plus C II Condenser Bushings Technical Guide

dfdf 34.5 kv and 69 kv, Type O Plus C II Condenser Bushings Technical Guide dfdf 34.5 kv and 69 kv, Type O Plus C II Condenser Bushings Technical Guide Table of contents 1 Introduction... 3 1.1 Style Number... 3 1.1.1 Style Number Examples... 3 2 Basic Characteristics... 4 2.1

More information

Installation Instructions for R-Frame Circuit Breakers and Molded Case Switches

Installation Instructions for R-Frame Circuit Breakers and Molded Case Switches Instruction Leaflet IL29C107N Effective January 2012 Supersedes IL29C107M 8/11 Installation Instructions for R-Frame Contents Description Page 1. Introduction........................... 2 2. Installation............................

More information

Type L Cutouts. UltraSIL Polymer-Insulated and Porcelain Type L Open Distribution Cutout. Description

Type L Cutouts. UltraSIL Polymer-Insulated and Porcelain Type L Open Distribution Cutout. Description Type L Cutouts UltraSIL Polymer-Insulated and Porcelain Type L Open Distribution Cutout Electrical Apparatus 327-30 Description Cooper Power Systems has set a new standard of excellence for polymer distribution

More information

VERTICAL TURBINE PUMPS SECTION 115. Discharge Head and Accessories

VERTICAL TURBINE PUMPS SECTION 115. Discharge Head and Accessories Peerless Pump Company SECTION 115 Page 0.1 May 19, 2005 Application Data Discharge Head and Accessories INDEX DATA & DIMENSIONS ITEM Type C & CHP 4 Type FA, FRA 7 Type S & SHP 5 Type UG 6 Column Flange,

More information

Advance design OEM L-Frames, cell kits, & enclosures Metal-clad switchgear components OEM catalog & pricing

Advance design OEM L-Frames, cell kits, & enclosures Metal-clad switchgear components OEM catalog & pricing Advance design OEM L-Frames, cell kits, & enclosures Metal-clad switchgear components OEM catalog & pricing Introduction A modular system of switchgear building blocks and cassettes provide untouchable

More information

25-kV Apparatus Bushings A Series (clamp-in) for Elbow to Air-Insulated Service 200 Amp and 600 Amp

25-kV Apparatus Bushings A Series (clamp-in) for Elbow to Air-Insulated Service 200 Amp and 600 Amp Page 1 2018 Grounded Metal Equipment Plate Equipment Connection 15 kv or 25 kv Separable Insulated Connector (elbow) Grounded Metal Equipment Plate Equipment Connection Power Cable Power Cable ELRIM Cycloaliphatic

More information

1ZSE en, Rev. 9. Transformer bushings, type GOB Technical guide

1ZSE en, Rev. 9. Transformer bushings, type GOB Technical guide 1ZSE 2750-102 en, Rev. 9 Transformer bushings, type GOB Technical guide Original instruction The information provided in this document is intended to be general and does not cover all possible applications.

More information

35-kV Safefront 200 Amp Primary Metering Station Pad-Mounted Outdoor

35-kV Safefront 200 Amp Primary Metering Station Pad-Mounted Outdoor ulletin Page 1 2016 Heavy duty 11-gauge steel enclosure is all-welded construction for long life 11-gauge steel equipment plate is rigid for easier elbow operation Upper parking stands extend 3" per IEEE

More information

Supplementary Instructions for Mechanical Latch Attachment for Type SJA or SJO Contactor Single or Dual Trip, 360 Amp~re

Supplementary Instructions for Mechanical Latch Attachment for Type SJA or SJO Contactor Single or Dual Trip, 360 Amp~re Supplementary nstructions for Mechanical Latch Attachment for Type SJA or SJO Contactor Single or Dual Trip, 36 Ampre. L. 16 2-35A Fig. 1 Type SJO with Latch Attachment APPLCATON trip the latch arm - when

More information

I nstallation I nstruction Heatshrink Term ination For 3 Core Polym eric Cables 7.2 kv to 3 6 kv

I nstallation I nstruction Heatshrink Term ination For 3 Core Polym eric Cables 7.2 kv to 3 6 kv I nstallation I nstruction Heatshrink Term ination For 3 Core Polym eric Cables 7.2 kv to 3 6 kv I NDOOR OUTDOOR ISSUE DATE: 05.01.11 General Fitting I nstructions * I t is highly recom m ended that a

More information

35-kV Thru-Bushings F Series (bolt-in) for Air-Insulated to Air-Insulated Service 200 Amp, 600 Amp, 900 Amp and 1250 Amp

35-kV Thru-Bushings F Series (bolt-in) for Air-Insulated to Air-Insulated Service 200 Amp, 600 Amp, 900 Amp and 1250 Amp Page 1 2018 Equipment Connection Bus Bar, or Grounded Metal Equipment Plate F Series Mounting Holes ELRIM Cycloaliphatic Epoxy Provides: Nontracking, self-scouring, nonweathering performance Superior dielectric

More information

Cutouts (Standard, Linkbreak, Loadbreak) and Cutout-Arrester Combinations. Catalog 10A January 2014

Cutouts (Standard, Linkbreak, Loadbreak) and Cutout-Arrester Combinations. Catalog 10A January 2014 10A Type C PORCELAIN Cutouts (Standard, Linkbreak, Loadbreak) and Cutout-Arrester Combinations Catalog 10A Page 1 Type C Cutouts LINKBREAK cutout, pages 8-10 LOADBREAK cutout with Arc-Chute interrupter,

More information

Specifications. S&C Type XS Fuse Cutouts. Outdoor Distribution (4.16 kv through 25 kv)

Specifications. S&C Type XS Fuse Cutouts. Outdoor Distribution (4.16 kv through 25 kv) Outdoor Distribution (4.16 through 25 ) Specifications Conditions of Sale STANDAD: Seller s standard conditions of sale set forth in Price Sheet 153 apply, except as modified under WAANTY QUALIFICATIONS

More information

1E EJB Junction Boxes Cl. I, Div. 1 and 2, Groups B, C, D

1E EJB Junction Boxes Cl. I, Div. 1 and 2, Groups B, C, D EJB Junction Boxes Cl. I, Div. and 2, Groups B, C, D Cl. II, Div., Groups E, F, G Cl. II, Div. 2, Groups F, G Cl. III NEMA 3, 4, 4X*,, Ex d IIB + H2 T6, IP66 Explosionproof Dust-Ignitionproof Raintight

More information

Resin Impregnated Paper Bushing, Oil to Air, Type GSB Technical guide

Resin Impregnated Paper Bushing, Oil to Air, Type GSB Technical guide 1ZSC000563-AAC en, Rev. 2 Resin Impregnated Paper Bushing, Oil to Air, Type GSB Technical guide This Technical Guide has been produced to allow transformer manufacturers, and their designers and engineers,

More information

Transformer bushings, type GOH. Technical guide

Transformer bushings, type GOH. Technical guide Transformer bushings, type GOH Technical guide This Technical Guide has been produced to allow transformer manufacturers, and their designers and engineers, access to all the technical information required

More information