Westinghouse Electric Corporation Distribution Apparatus Division Bloomington, Indiana Indoor-Outdoor Altitude 0-1 0,000 feet KV

Size: px
Start display at page:

Download "Westinghouse Electric Corporation Distribution Apparatus Division Bloomington, Indiana Indoor-Outdoor Altitude 0-1 0,000 feet KV"

Transcription

1 December 1975 New nformation and Supersedes F WE A, Pages 1-, dated May 1975, and DS , pages 1-2, dated December, 1973 E, D, C/1981/DB Dimensions, Weights and Creep These notes apply to all ratings 1. These arresters are designed for 10,000 feet. ncrease clearances "S" and "T" 3% for each feet over 6000 feet. 2. When installed, exhaust ports should be directed away from adjacent apparatus. Ratings above 312 KV do not have directional venting. 3. Arrester assembly consists of arrester unit, line terminal assembly, ground terminal bracket, grading ring (if required), all hardware (excluding base mounting hardware). master nameplate, and line and ground connectors.. Arrester assemblies made up of more than one unit do not have interchangeable units. 5. Add 6.00 inches to "" dimension when using an insulating post. Add inches to "" dimension when using an insulating base for ratings 60-68KV, and 1.75 inches for ratings 3-8KV. 6. Line and ground clamp type connectors suitable for copper or aluminum conductors with diameter of 0.25 to 0.75 inches. Line terminal connectors accomodate conductors with diameter of inches on porcelain top arresters. ndoor-outdoor Altitude 0-1 0,000 feet 2-68 KV Porcelain Top 3-2 KV See Enlarged V1ew of Term1nal ( Deta11 "A") Figure l ( O.D. 5057A93) Mounting Dimensions ( 3 Phase nstallation Layout) 1--- s ----<-> (See Mounting D1mens1onsl Mounting ole for.500 Diameter Bolts --7-T-T---:?'t (Thickness of Lug on Casting.750) Style Kv Rating 5556A60A A60A0 5556A60A A60A A60A A60A A60A A60A A60A A60A2 2.5 ]-imesions (nches),, i F WE A Page 1 Station Arrester Type CPL Controlled Protective Level Detaii " A " s it Creep ' L1ne Term 1na Coble S1ze#2to 350MCM,.255 to.681 nch D1ameter lr, Weight (Lbs.) Figure

2 38-12 F WE A Page 2 Metal Top 3-8 KV See Enlarged View of Terminal ( Detai "A") Figure 2 ( O.D. 5057A90) See Enlarged View of Terminal (Detail "A") Figure 3 ( O.D. 5057A9l) s ---v (See Mounting D1mens1onsl s --..v (See Mountmg Dimensions) Un1t Nameplate Master Detaii"A'.562 Diameter () oles Mounting Dimensions h= 3.0 = Thick (Reference Term mal) ' =il 1.75 (3 Phase nstallation Layout) ir Mounting ole for.500 D1ameter Bolts '---T-----'tl-1- (Thickness of Lug on Casting.750 ) Style 5556A61 A A61A0 5556A61A A61A A61 A A61 A A61A A61A A61 A A61A2 5556A61A A61A A61A A61A A61A5 5556A61A8 Kv Rating Dimensions _, -r2 g; ' Weight s T Creep (lbs.) --- Figure ::> <D Q_ , c "'

3 8 December 1975 New nformation and Supersedes F WE A, Pages 1 -, dated May 1975, and OS , pages 1-2, dated December, 1973 E, D, C/1981 /DB Metal Top KV See Enlarged V1ew of Term mal ( Oeta11 ''A") Figure { O.D. 3895A82) See Enlorged View of Terminal (Detail "A") Figure 5 { O.D. 3895A8) ndoor-0 utdoor Altitude 0-1 0,000 feet 2-68 KV Detoii " A ".562 D1ameter ( ) oles lr 3.0 = ThiCk 1.75 (Reference Terminal) Mounting Dimensions ( 3 Phase nstallation Layout) -$ Mounting ole for.750 Diameter Bolts---'7-"r: ---->t (Thickness of Lug on Casting 1.00) Style 1 -_ 3891 A06A A07A A09A A09A61 Kv Rating A10A A 12A A13A A1A A16A A 18A A19A F WE A Page 3 Station Arrester Type CPL Controlled Protective Level Dimensions (nches) Weight Figure!, D dia. R s--1 _T Creep (Lbs.) !

4 38-12 F WE A Page Metal Top KV. t!j n===ejl s '! j : Figure 6 ( O.D. 899Al9) ' j D:mens:ons) (See Mountmg ;,:; :(; Detail " A ".562 D:ameter-+--i--- / () oles Mounting Dimensions (3 Phose nstallation Layout) Mount:ng ole for.750 D:ameter Bolts (Thickness of Lug on Cast:ng 1.00) 10 D:ameter Bolt C:rcle S- Rad:us Exhaust Vent Ports Style Kv Dimensions (nches) Rating, A22A A2A A25A A26A A27A A28A A30A A31A Th:ck (Reference Terminal) D Dia. R S T Creep Weight (Lbs.) Figure

5 December 1975 New nformation and Supersedes F WE A, Pages 1-, dated May 1975, and DS , pages 1-2, dated December, 1973 E, D, C/1981/DB Metal Top KV See Enlarged View of Terminal (Detail "A") Figure 7 ( O.D. 3889A 1) ndoor-outdoor Altitude 0-10,000 feet 2-68 KV Detail " A ".562 Diometer--==-tt=;t!T -f-+*-1- (3) oles.625 Thick F WE A Page 5 Station Arrester Type CPL Controlled Protective Level Mounting Dimensions 1--- T T ( 3 Phose nstallation Layout) orizontal Limit for Grounded Objects/ Mount1ng ole for.750 D1ometer Bolts--7---"'r'?\ (Thickness of Lug oncast1ng.875 ) D1ameter Bolt Crcle Style Kv Dimensions {nches) Weight Rating eights Grading Rings Clearances Creep Lbs.,, D, R, D, R, D3 R3 o. R s T 3891A39A A2A AA A6A Figure

6 ' F WE A Page 6 CPL Arrester nsulating Bases and Posts D1ameter Gray S!15559A88A A83 Figure 8. nsulating Base (3-8 Kv) ::e.:::;;:,)jt Ground Connection ifrecordmg or Arrester Unit " Bottom ), Arrester Unit '-o-----,-j / - A - - =-?0-A D1ameter \,_) - - t 60 l i_ o.75 -lostud, Lock washer and Nut Section A-A Gray S!1898A935A A97 Figure 11. nsulating Posts ( Kv) Mounting oles for.75 0 Diameter Bolts 1 0 Diameter Gray S!1898A95A A053 Figure 9. nsulating Base ( Kv) Bottom ; Arrester Unit A,.---'7===-=====-'-=-.j..., 6.ofi---- T, 1.75 Section A-A ll!'l"'-- Mounting oles for.75 0 Diameter Bolts Ground Connection 1f Recordmg or Measunng Equipment S Nat Used A Stud, Lock washer and Nut Diameter Gray S!1898A935A A03 Figure 12. nsulating Posts ( Kv) Ground Connection 1f Recording or Measunng Equ1pment S Not Used Mounting oles for.75 0 Diameter Bolts D1ameter Gray S i115039a06a A 16 Figure 10. nsulating Base (396-68Kv) Bottom ArresterUn1t

7 . 8 December 1975 New nformation and Supersedes F WE A, Pages 1-, dated May 1975, and DS , pages 1-2, dated December, 1973 E, D, C/1981 /DB Diameter ole Nameplate 0.tt S 11633A700A01 w/o Leakage Current ndicator A30 S 11633A797 A01 with Leakage Current ndicator A25 Figure 13. Discharge Counters (3-68 Kv) Diameter oles ( 6) ( 3) on o ( 3) on o Bolt Crcle X5.500 Long Galvanized Steel Crg. Bolt W/Washer, Lockwosher and Nut ( Supplied) LJ Bock Strap 12.0 (2 Suppl1ed) ( Ref. l S 11279C251 A08 0. D. 663A09 Figure 16. Single Crossarm Reversible Bracket (3-39 Kv) ndoor-outdoor Altitude 0-1 0,000 feet 2-68 KV.562 Diameter ( 3) Equal ly Spaced os Shown.500Thick Reference Terminal and Top Plate.562 Diameter () oles S!ii63A088A A50 Figure 1. Line Terminal for Suspension Mounting (3-8 Kv) J ---, r h T : f-.- T. : : 687 Diameter ( 8) oles : :V for.625 ardware j 1 --J.r--_ =t 1: Sii279C251 A10 O.D. 663A1 1 Figure 17. Wall Mounting Bracket (3-8 Kv) F WE A Page 7 Station Arrester Type CPL Controlled Protective Level 10 D1ometer.06 Rod ius D1ometer Th<.625 Rod ius Reference Term1nol and Top Plate Diameter ( ) oles S 11662A99A01 0. D. 5038A9 Figure 15. Line Terminal for Suspension Mounting ( Kv) S C251A09 O.D. 663A1 0 Figure 18. Baseplate (3-8 Kv) r --_j ) --

8 38-12 F WE A Page Drameter ( ) Equally Spaced on Drameter Si!i63A799A01 O.D. 5565A75 Figure 19. Adapter Plate SV to CPL (3-8 Kv) Further nformation P WE A D WE A T WE A.625 Diameter oles ( 6) ( 3) on a ( 3) on a Mounting Bracket May be Reversed for Reversed Mounting of Mounting JJ (2 Supplied) \--- - Back Strap X5.500 Long Galvanrzed Steel Crg. Bolt W Washer, Lockwasher and Nut ( Supplied) 1.625(Ref.) N=Mountrng Centers of Bolts are.875, 5.750, and 7.00 nches N2 = Mountrng Centers of Bolts Ranges from to S i!i279c251a07 O.D. 663A08 Figure 20. Double Crossarm Mounting Bracket

Westinghouse Electric Corporation Distribution Apparatus Division Bloomington, Indiana Indoor-Outdoor Altitude 0-10,000 feet KV

Westinghouse Electric Corporation Distribution Apparatus Division Bloomington, Indiana Indoor-Outdoor Altitude 0-10,000 feet KV May 975 Supersedes 8-2 F WE A, Pages -2, dated January 975 E, D, C/98 /DB Dimensions, Weights and Creep These notes apply to all ratings.. These arresters are designed for 0,000 feet. ncrease clearances

More information

PSC Terminations. Features Class 1 (outdoor) termination as defined in IEEE 48 standard. For use on all extruded dielectric cables.

PSC Terminations. Features Class 1 (outdoor) termination as defined in IEEE 48 standard. For use on all extruded dielectric cables. Features Class 1 (outdoor) termination as defined in IEEE 48 standard. For use on all extruded dielectric cables. Sizes are available for all shielded cables in voltage classes from 15kV through 46kV.

More information

www. ElectricalPartManuals. com CPL Station Arrester Controlled Protective Level Page 1 Indoor-Outdoor Altitude 0-10,000 feet KV

www. ElectricalPartManuals. com CPL Station Arrester Controlled Protective Level Page 1 Indoor-Outdoor Altitude 0-10,000 feet KV December, 1975 New nformation and Supersedes DB 38-131 Pages 1-4, dated May 1972, and 38-121 D WE A, Pages 1-4, dated April1974 E, D, C/1981/ DB Westinghouse Electric Corporation Distribution Apparatus

More information

Kuhlman Electric Corporation Volt Instrument Transformers

Kuhlman Electric Corporation Volt Instrument Transformers Kuhlman Electric Corporation 46000 Volt Instrument Transformers 46000 Volt Table of Contents Description Model Page Wound, Dry-Type VT (High Accuracy available) U/VRU-52(H) 3-4 Wound, Oil-Filled VT (High

More information

M-Force three-phase switch

M-Force three-phase switch Supersedes K-SEC 926 December 2012 M-Force three-phase switch Description The M-Force switch from Eaton's Cooper Power Systems is a distribution-class, gangoperated, factory unitized three-phase overhead

More information

Westinghouse Electric Corporation Distribution Apparatus Division Bloomington, Indiana 47401

Westinghouse Electric Corporation Distribution Apparatus Division Bloomington, Indiana 47401 February 26, 1976 Supersedes PL 38-640 dated October 15,1974 Pages 1-8 Prices effective April 29, 1974 Subject to change without notice Selling Policy 38-000 Mailed to E, D, C/1991, 2430/ PL Standard Bill

More information

SUBSTATION BUS-SUPPORT FITTINGS

SUBSTATION BUS-SUPPORT FITTINGS SUBSTATON BUSSUPPORT FTTNGS EHV ALUMNUM BUSSUPPORT FTTNGS FOR ALUMNUM TUBNG PCTORAL NDEX SUBJECT AUP Clamp (Bolted) or Slide 5inch Bolt Circle WAUPDR Fixed (Weld) or Slide 5inch Bolt Circle Double Ring

More information

Steel Fabrications Equipment Brackets

Steel Fabrications Equipment Brackets April 2004 Page 25 of 43 H. R. Steel; Each bracket includes (2) 1/2 x 1 hex bolts, flat washers, and special retaining clips as well as (1) 1/2 x 2 captive carriage bolt, shake proof washer, lockwasher,

More information

M-Force three-phase switch

M-Force three-phase switch Switches and Disconnects CA008004EN Supersedes May 2015 COOPER POWER SERIES M-Force three-phase switch Description Eaton's Cooper Power series M-Force switch is a distribution-class, gang-operated, factory

More information

Indoor or Outdoor 2400 to 14,400 Volts 600 to 14,400 Kvac, 3 Phase, 60 Hz

Indoor or Outdoor 2400 to 14,400 Volts 600 to 14,400 Kvac, 3 Phase, 60 Hz c February, 1979 Supersedes DB 39-485, pages 1-4, dated November, 1973 Mailed to: E, D, C/2001, 2002/DB Benefits There are many capacitor applications in which factors such as physical location, personnel

More information

Maximum submersible power cable length (max. cable length in feet - starter to motor)

Maximum submersible power cable length (max. cable length in feet - starter to motor) Cable sizing charts V and 0 V, ph V ph 0 V ph 0. 0. 0 (40) 00 (0) 0 (68) 00 0 (9) 90. (8) 0 (46) 0 (7) - 0 (64) 60 (49) 880 (68) (98) 480 (46) 0 90 (8) 0* (4*) 7. 40 (04) 90 (44) 00 () () 60 (9) 480 (46)

More information

UltraSIL polymer-housed VariSTAR station-class surge arresters

UltraSIL polymer-housed VariSTAR station-class surge arresters Surge s Catalog Data CA235013EN Supersedes August 2015 COOPER POWER SERIES UltraSIL polymer-housed VariSTAR station-class surge arresters General Eaton has set a new standard of excellence for polymer-housed

More information

TYPE BLT DISCONNECT SWITCHES

TYPE BLT DISCONNECT SWITCHES TYPE BLT DISCONNECT SWITCHES OUTDOOR-HOOK OPERATED 8.3KV through 38KV A & A Current Furnished with hooks for loadbreak tool REA/RUS approved S M C O 1 BLT PARALLEL BLADE DISTRIBUTION CLASS DISCONNECT SWITCH

More information

D-73P disconnect and bypass switches

D-73P disconnect and bypass switches Switches atalog Data 008005EN Supersedes pril 2016 OOPER POWER SERIES D-73P disconnect and bypass switches ontents Description Page D-73P disconnect switch....2 D-73P3 bypass switch....5 D-73P-D cutout

More information

VariSTAR Type AZE station-class surge arresters for systems through 345 kv IEEE certified

VariSTAR Type AZE station-class surge arresters for systems through 345 kv IEEE certified Surge s Catalog Data CA235022EN Supersedes TD235009EN September 2014 COOPER POWER SERIES VariSTAR Type AZE station-class surge arresters for systems through 345 kv IEEE certified General Eaton s Cooper

More information

BRACKETS, MOUNTS & HARDWARE

BRACKETS, MOUNTS & HARDWARE HIGH VOLTAGE SWITCHGEAR & AUTOMATION EQUIPMENT SECTION 6 Brackets, Mounts & Misc. Hardware CAT. NO: 040930G May, 2008 INERTIA Engineering & Machine Works, INC. Fax: (209) 931-8186 6665 Hardaway Road, Stockton,

More information

UltraSIL polymer-insulated and porcelain loadbreak Type LB open distribution cutout

UltraSIL polymer-insulated and porcelain loadbreak Type LB open distribution cutout Fusing Equipment Catalog Data CA132035EN Supersedes November 2015 COOPER POWER SERIES UltraSIL polymer-insulated and porcelain loadbreak Type LB open distribution cutout Description Eaton has set a standard

More information

Surge Arresters. UltraSIL Housed VariSTAR Station Class Surge Arresters GENERAL CONSTRUCTION

Surge Arresters. UltraSIL Housed VariSTAR Station Class Surge Arresters GENERAL CONSTRUCTION Surge Arresters UltraSIL Housed VariSTAR Station Class Surge Arresters Electrical Apparatus 235-88 GENERAL Cooper Power Systems has set a new standard of excellence for polymerhoused station class surge

More information

Lightning Protection Equipment

Lightning Protection Equipment LINE CARD Grounding Exothermic Lightning Protection Lightning Protection Equipment Manufacturing Engineering Services Training Typical Roof Lightning Protection Layout 8 6 1 4 Mounted Vertically (with

More information

GENERAL. CONSTRUCTION External

GENERAL. CONSTRUCTION External Surge Arresters VariSTAR Type AZG4 Surge Arresters for Systems through 400 kv IEC 20-kA; Line Discharge Class 4 Electrical Apparatus I235-84 GENERAL VariSTAR AZG4 Surge Arresters incorporate the latest

More information

www. ElectricalPartManuals. com GENERAL. ELECTRIC RENEWAL PARTS METAL-CLAD SWITCHGEAR TYPES M-26 AND M-36 GEF-4351C Supersedes GEF-4351B

www. ElectricalPartManuals. com GENERAL. ELECTRIC RENEWAL PARTS METAL-CLAD SWITCHGEAR TYPES M-26 AND M-36 GEF-4351C Supersedes GEF-4351B Data subject to change without notice. RENEWAL PARTS METAL-CLAD SWTCHGEAR TYPES M-26 AND M-36 ORDERNG NSTRUCTONS 1. Always specify the complete nameplate data of the equipment. GEF-4351C Supersedes GEF-4351B

More information

Type POLIM-S Surge Arresters Maximum System Voltage 2.52 to 245 kv

Type POLIM-S Surge Arresters Maximum System Voltage 2.52 to 245 kv Type POLIM-S Surge Arresters Maximum System Voltage 2.52 to 245 kv POLIM-S Metal Oxide Gapless Surge Arresters POLIM-S Surge Arresters are used for the protection of switchgear, transformers and other

More information

sirco-ul_004_b_cat 100A to 2000A - 600VDC and 1000VDC UL98B Listed

sirco-ul_004_b_cat 100A to 2000A - 600VDC and 1000VDC UL98B Listed site_317_a sirco-ul_22_b_cat sirco-ul_4_b_cat 1A to 2A - 6VDC and 1VDC UL98B Listed  Function non fusible disconnects are heavy duty switches that break and make 6VDC or 1VDC photovoltaic circuits on

More information

Type M3 Hookstick Disconnect Switches Up to 38kV 600 or 900 Amp 40kA Momentary

Type M3 Hookstick Disconnect Switches Up to 38kV 600 or 900 Amp 40kA Momentary 14B-2 Type M3 Hookstick Disconnect Switches Up to 38kV 0 or 900 Amp 40kA Momentary Application The Chance Type M3 Disconnect Switch is a single-phase hookstick operated switch. It is for manual switching

More information

SYSTEM PROTECTION - PLATING

SYSTEM PROTECTION - PLATING INTRODUCTION 1. Plates F1 thru F10 supply only the material required for one-phase. Therefore, for threephase construction, you will be required to call for the specified plate three times at that station.

More information

Disconnect & ByPass Switches

Disconnect & ByPass Switches Disconnect & ByPass Switches Disconnect & Oil Circuit Recloser Bypass Switches; Regulator & Current Transformer Bypass Switches Electrical Apparatus K-SEC 060 & 090 Contents Type D-73 Distribution Class

More information

Surge arresters. UltraSIl Polymer-Housed VariSTar Type UI Intermediate-Class Surge arresters. General. COnSTrUCTIOn

Surge arresters. UltraSIl Polymer-Housed VariSTar Type UI Intermediate-Class Surge arresters. General. COnSTrUCTIOn Surge arresters UltraSIl Polymer-Housed VariSTar Type UI Intermediate-Class Surge arresters electrical apparatus 235-75 General Cooper Power Systems has set a new standard of excellence for polymerhoused

More information

Hubbell has a policy of continuous product improvement. Please visit hubbellpowersystems.com to confirm current design specifications.

Hubbell has a policy of continuous product improvement. Please visit hubbellpowersystems.com to confirm current design specifications. Line Post Sensors Product Instruction Manual Hubbell has a policy of continuous product improvement. Please visit hubbellpowersystems.com to confirm current design specifications. 2018 Hubbell Incorporated

More information

Catalog 14A January 2013

Catalog 14A January 2013 Catalog 14A January 2013 Page 1 January 2013 Type AR (Automation-Ready) Switch 14.4kV, 25kV or 34.5kV 900 Amperes Continuous/Interrupt Description The Hubbell unitized Type AR switch is a distribution-level,

More information

25 kv Apparatus Bushings

25 kv Apparatus Bushings Page 1 2001 ELRIM Cycloaliphatic Epoxy Provides: Nontracking, self-scouring, nonweathering performance Superior dielectric strength, dielectric loss and power factor Choice of shapes allows design innovation

More information

Type L Cutouts. UltraSIL Polymer-Insulated and Porcelain Type L Open Distribution Cutout. Description

Type L Cutouts. UltraSIL Polymer-Insulated and Porcelain Type L Open Distribution Cutout. Description Type L Cutouts UltraSIL Polymer-Insulated and Porcelain Type L Open Distribution Cutout Electrical Apparatus 327-30 Description Cooper Power Systems has set a new standard of excellence for polymer distribution

More information

Resin Impregnated Paper Bushing, Oil to Air, Type GSB Technical guide

Resin Impregnated Paper Bushing, Oil to Air, Type GSB Technical guide 1ZSC000563-AAC en, Rev. 2 Resin Impregnated Paper Bushing, Oil to Air, Type GSB Technical guide This Technical Guide has been produced to allow transformer manufacturers, and their designers and engineers,

More information

www. ElectricalPartManuals. com (fr} lite Imperial Carporatian ''- METAL-ENCLOSED, FUSED-INTERRUPTER SWITCH INSTRUCTIONS

www. ElectricalPartManuals. com (fr} lite Imperial Carporatian ''- METAL-ENCLOSED, FUSED-INTERRUPTER SWITCH INSTRUCTIONS METAL-ENCLOSED, FUSED-NTERRUPTER SWTCH NSTRUCTONS STANDARD MANUAL OPERATNG MECHANSM The -T-E interrupter swit ch operating me chanism is a st ored-energy device. This st ored-energy device operat es independently

More information

25-kV Apparatus Bushings B Series (bolt-in) for Elbow to Air-Insulated Service 200 Amp, 600 Amp, 900 Amp and 1250 Amp

25-kV Apparatus Bushings B Series (bolt-in) for Elbow to Air-Insulated Service 200 Amp, 600 Amp, 900 Amp and 1250 Amp Page 1 2018 Grounded Metal Equipment Plate Equipment Connection Bus Bar or Other Component 15 kv or 25 kv Separable Insulated Connector (elbow) Equipment Connection Power Cable Power Cable ELRIM Cycloaliphatic

More information

35-kV 200-kV BIL Apparatus Bushings B Series (bolt-in) for Elbow to Air-Insulated Service 200 Amp, 600 Amp, 900 Amp and 1250 Amp

35-kV 200-kV BIL Apparatus Bushings B Series (bolt-in) for Elbow to Air-Insulated Service 200 Amp, 600 Amp, 900 Amp and 1250 Amp Page 1 2018 Grounded Metal Equipment Plate Equipment Connection 35 kv Separable Insulated Connector (elbow) Bus Bar or Other Component Grounded Metal Equipment Plate Equipment Connection Bus Bar or Other

More information

Volt Instrument Transformers

Volt Instrument Transformers www. kuhlman. com Kuhlman Electric Corporation Instrument Transformers 1 Table of Contents Description Model Page Wound, Oil-Filled VT (High Accuracy available) UTE-145-OH 3-4 Wound, Oil-Filled CCVT (High

More information

Circuit Breaker Accessories BREQS125 BRHDK125

Circuit Breaker Accessories BREQS125 BRHDK125 anuary 2008 Loadcenters & ircuit reakers Type R Loadcenters & ircuit reakers ircuit reaker ccessories -75 ircuit reaker ccessories TS LW2 RLW2 RQS25 TOW (nstalled) MPL (nstalled) RQLW LW RK25 RML Table

More information

35-kV Apparatus Bushings B Series (bolt-in) for Elbow to Air-Insulated Service 200 Amp, 600 Amp, 900 Amp and 1250 Amp

35-kV Apparatus Bushings B Series (bolt-in) for Elbow to Air-Insulated Service 200 Amp, 600 Amp, 900 Amp and 1250 Amp Page 1 2018 Grounded Metal Equipment Plate Equipment Connection Bus Bar or Other Component 35 kv Separable Insulated Connector (elbow) Grounded Metal Equipment Plate Equipment Connection Bus Bar or Other

More information

Features and Application

Features and Application ML-DTL- Features and Application MS2426*/AE66* Features and Application ML-DTL- family offers connectors with bayonet coupling as well as threaded coupling. These connectors are intermateable with correspondingly

More information

Surge Arresters. UltraSIL Polymer-Housed VariSTAR Surge Arresters: Normal-Duty (5 ka), Heavy-Duty (10 ka), and Heavy-Duty Riser Pole (10 ka)

Surge Arresters. UltraSIL Polymer-Housed VariSTAR Surge Arresters: Normal-Duty (5 ka), Heavy-Duty (10 ka), and Heavy-Duty Riser Pole (10 ka) Surge s UltraSIL Polymer-Housed VariSTAR Surge s: Normal-Duty (5 ka), Heavy-Duty (10 ka), and Heavy-Duty Riser Pole (10 ka) Electrical Apparatus 235-35 General Cooper Power Systems has set the standard

More information

www. ElectricalPartManuals. com

www. ElectricalPartManuals. com Instructions for Parcel-Line Type DH-P Circuit Breakers with Post Insulator Type Pole Units (Supplements I. B. 32-253-2) Westinghouse Electric Corporation Switchgear Division, East Pittsburgh, Pa. 15112

More information

Figure 1. HX cutout fuseholders.

Figure 1. HX cutout fuseholders. Fusing Equipment Kearney Open Distribution Cutout - Type HX Electrical Apparatus K-SEC 010 GENERAL Application Versatility Cooper Power Systems Kearney HX cutouts can be quickly and economically adapted

More information

230 kv Aluminum Bolted Couplers TYPE BCX-AA. Ordering Information. or

230 kv Aluminum Bolted Couplers TYPE BCX-AA. Ordering Information.   or 20 kv Aluminum 20 kv Aluminum TYPE CX-AA Variable Cable Tee Tap and Straight Connector A clamp type tee connector, or reducer connector for joining two cables. This connector allows for multiple applications,

More information

1ZSE EN, REV. 7. Oil SF 6. bushings type GOEK Technical guide

1ZSE EN, REV. 7. Oil SF 6. bushings type GOEK Technical guide 1ZSE 2750-106 EN, REV. 7 Oil SF 6 bushings type GOEK Technical guide Original instruction The information provided in this document is intended to be general and does not cover all possible applications.

More information

DynaVar Arresters IEC Line Discharge Classes 2, 3, 4 & 5

DynaVar Arresters IEC Line Discharge Classes 2, 3, 4 & 5 Section 204-1 204 DynaVar Arresters IEC Line Discharge Classes 2, 3, 4 & 5 Web: http://www.hubbellpowersystems.com E-mail: hpsliterature@hps.hubbell.com Printed in USA RGS 1M 204-2 Table of Contents Page

More information

Figure 1. HX cutout fuseholders. Positive Interruption

Figure 1. HX cutout fuseholders. Positive Interruption Fusing Equipment Kearney Open Distribution Cutout - Type HX Electrical Apparatus 327-10 general Application Versatility Cooper Power Systems Kearney HX cutouts can be quickly and economically adapted to

More information

HUBBELL Type M3 Hookstick Disconnect Switches Up to 38kV 600 or 900 Amp 40kA Momentary

HUBBELL Type M3 Hookstick Disconnect Switches Up to 38kV 600 or 900 Amp 40kA Momentary Catalog 14B January 2015 HUBBELL Type M3 Hookstick Disconnect Switches Up to 38kV 600 or 900 Amp 40kA Momentary Application The Chance Type M3 Disconnect Switch is a single-phase hookstick operated switch.

More information

CLEAVELAND / PRICE INC. Type RL-C Side Break Switch kv A. Bulletin DB-104E12

CLEAVELAND / PRICE INC. Type RL-C Side Break Switch kv A. Bulletin DB-104E12 Bulletin DB-104E12 Type RL-C Side Break Switch 7.2-69 kv 600-2000 A. CLEAVELAND / PRICE INC. 14000 Rt. 993, Trafford, PA 15085 (724) 864-4177 FAX (724) 864-9040 Email: sales@cleavelandprice.com Type RL-C

More information

Cutouts (Standard, Linkbreak, Loadbreak) and Cutout-Arrester Combinations. Catalog 10A January 2014

Cutouts (Standard, Linkbreak, Loadbreak) and Cutout-Arrester Combinations. Catalog 10A January 2014 10A Type C PORCELAIN Cutouts (Standard, Linkbreak, Loadbreak) and Cutout-Arrester Combinations Catalog 10A Page 1 Type C Cutouts LINKBREAK cutout, pages 8-10 LOADBREAK cutout with Arc-Chute interrupter,

More information

Chapter 1. Connectors & Fittings for Railways

Chapter 1. Connectors & Fittings for Railways Chapter Connectors & Fittings for Railways Current Carrying Catenary Dropper Component N Messenger Bz Cable length from L Component N 3 Component N 2 Contact Wire SNCF approved This dropper provides a

More information

Submittal Data 3450 RPM 60 Hertz JOB or CUSTOMER:

Submittal Data 3450 RPM 60 Hertz JOB or CUSTOMER: Redi-Flo4 Environmental Submersible Pumps 5E Submittal Data 3450 RPM 60 Hertz JOB or CUSTOMER: ENGINEER: CONTRACTOR: SUBMITTED BY: APPROVED BY: ORDER NO: SPECIFICATION REF: QUANTITY TAG NO. MODEL NO. GPM

More information

STANDARD PIPE CLAMP FIG. 520 & 521

STANDARD PIPE CLAMP FIG. 520 & 521 Designed to be used in the suspension of non-insulated pipe lines. Normally used in conjunction with Fig. 35 weldless eye nut, Fig. 50 eye rod or Fig. 55 welded eye rod to allow flexibility at the rod

More information

www. ElectricalPartManuals. com SPECIFICATIONS Page 1 of 24 March 24, 2003

www. ElectricalPartManuals. com SPECIFICATIONS Page 1 of 24 March 24, 2003 Types SM-4, SM-5, SMD-20, and SMD-40 Outdoor Distribution (4.16 kv through kv) Conditions of Sale STANDARD: Seller s standard conditions of sale set forth in Price Sheet apply, except as modified under

More information

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT:

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT: 036-21323-001-B-0202 GENERAL SPECIFICATIONS OUTDOOR UNIT: Two independent refrigerant circuits Inherently protected fan motors Two independent scroll compressors V-Coil Design Exterior service port connections

More information

Cutouts (Standard, Linkbreak, Loadbreak) and Cutout-Arrester Combinations. Catalog 10A October 2015

Cutouts (Standard, Linkbreak, Loadbreak) and Cutout-Arrester Combinations. Catalog 10A October 2015 10A Type C PORCELAIN Cutouts (Standard, Linkbreak, Loadbreak) and Cutout-Arrester Combinations Catalog 10A Page 1 Type C Cutouts LINKBREAK cutout, pages 8-10 LOADBREAK cutout with Arc-Chute interrupter,

More information

GE TRANQUELLTM Surge Arresters

GE TRANQUELLTM Surge Arresters GE Digital Energy GE TRANQUELLTM Surge Arresters Product Selection & Application Guide Heavy Duty Distribution Class-Polymer and Riser Pole Polymer Arresters IEEE /ANSI C62.11 GE Surge Protection The performance

More information

Engineering Service Specifications. Commercial Single-Phase Current Transformer Metering Schemes

Engineering Service Specifications. Commercial Single-Phase Current Transformer Metering Schemes Engineering Service Specifications Commercial Single-Phase Current Transformer Metering Schemes Specifications for Commercial Underground Current Transformer Metering Requirements for a Single-Phase Customer

More information

General Cable Support Information

General Cable Support Information General Cable Support Information Applications Used to support cables in vertical raceways or risers. Relieves the strain that would be placed on terminations, the interior of panels, or other devices

More information

Specifications. S&C Power Fuses Types SM- 4, SM-5, SMD-20, and SMD-40 Outdoor Distribution (4.16 kv through 34.5 kv)

Specifications. S&C Power Fuses Types SM- 4, SM-5, SMD-20, and SMD-40 Outdoor Distribution (4.16 kv through 34.5 kv) S&C Power Fuses Types SM- 4, SM-5, SMD-0, and SMD-40 Outdoor Distribution (4.16 kv through kv) For use with SM Refill Units or SMU Fuse Units Specifications Conditions of Sale STANDARD: The seller s standard

More information

8 -- SQUARE D C:DMPRNV IDI POWER-ZONE- LOAD CENTER UNIT SUBSTATIONS LOW VOLTAGE DISTRIBUTION SECTIONS APPLICATION DATA

8 -- SQUARE D C:DMPRNV IDI POWER-ZONE- LOAD CENTER UNIT SUBSTATIONS LOW VOLTAGE DISTRIBUTION SECTIONS APPLICATION DATA Class 6020 JUNE!, 1984 Supersede& April, 1982!!dillon Load Center Unit Substations Description APPLCATON DATA General... 6020 2 ncoming Line Section 0 6020 Transformer Section 0 6020 6-7 Low Voltage Distribution

More information

www. ElectricalPartManuals. com It'll Cutler-Hammer WLI Medium Voltage Switchgear Renewal Parts Renewal Parts Data Page 1

www. ElectricalPartManuals. com It'll Cutler-Hammer WLI Medium Voltage Switchgear Renewal Parts Renewal Parts Data Page 1 t'll Cutler-Hammer Supersedes Renewal Parts Data, pages 1-2, dated June 1992 Renewal Parts Data Page 1 WL Medium Voltage Switchgear Renewal Parts Renewal Parts Data Page 2 WL Medium Voltage Switchgear

More information

Power Distribution Blocks

Power Distribution Blocks Power Distribution Blocks One powerful way to manage your power distribution problems. Your problem: You re facing the enormously complex wiring requirements of an automated manufacturing facility. Or

More information

Cutouts (Standard, Linkbreak, Loadbreak) and Cutout-Arrester Combinations. Catalog 10AA August 2015

Cutouts (Standard, Linkbreak, Loadbreak) and Cutout-Arrester Combinations. Catalog 10AA August 2015 10AA Type C-POLYMER Cutouts (Standard, Linkbreak, Loadbreak) and Cutout-Arrester Combinations Catalog 10AA Page 10AA-1 Quality Construction Efficient Current Transfer The Type C-Polymer cutout has an all

More information

PARTS MANUAL. American Dish Service ADS CONVEYOR DISHWASHER MODELS: ADC-66 L-R/R-L EFFECTIVE: MAY, 2011

PARTS MANUAL. American Dish Service ADS CONVEYOR DISHWASHER MODELS: ADC-66 L-R/R-L EFFECTIVE: MAY, 2011 EFFECTIVE: MAY, 2011 ADS CONVEYOR DISHWASHER MODELS: ADC-66 L-R/R-L PARTS MANUAL 900 Blake Street Edwardsville, Kansas 66111 (913)422-3700 05/08 213-0066 L-R / 214-0066 R-L ADC-66 Conveyor Dishwasher 2

More information

Type HS PEXLIM-P Surge Arresters Maximum System Voltage 123 kv to 800 kv

Type HS PEXLIM-P Surge Arresters Maximum System Voltage 123 kv to 800 kv Type HS PEXLIM-P Surge Arresters Maximum System Voltage 123 kv to 800 kv HS PEXLIM-P Metal Oxide Surge Arrester HS PEXLIM-P Surge Arresters are used for the protection of switchgear, transformers and other

More information

Item Code Description Unit Qty Total

Item Code Description Unit Qty Total UNDP ELECTRICITY SECTOR NORTHERN GOVERNORATES Phase XI Item Code Description Unit Qty Total 04-02-00001 Service Pole - 6m, 75mm dia GS Pipe 11250 04-02-00002 9m Tubular Steel Poles complete with all Accessories

More information

STEEL. P ole P roducts

STEEL. P ole P roducts STEEL P ole P roducts Value. Durability. Safety. SSS A Mounting Height Square Straight Steel Pole No Arm Removable Pole Cap (Tenon Option Available - See Mounting Designation) D Top Square B Wall Gauge

More information

600A Deadbreak Elbow. K656LR Elbow Connector (with Test Point) Features:

600A Deadbreak Elbow. K656LR Elbow Connector (with Test Point) Features: Issue Date: 07/17/2017 Page: 1 of 5 PSS- K656LR Elbow Connector (with Test ) Applications: The Elastimold K656LR (with test point) is designed to provide fully shielded, dead-front submersible cable connections

More information

CPG Series. Submittal Data Form. 3- to 6-Ton Self-Contained. Packaged Gas/Electric. with R-410A

CPG Series. Submittal Data Form. 3- to 6-Ton Self-Contained. Packaged Gas/Electric. with R-410A CPG Series 3- to 6-Ton Self-Contained Submittal Data Form Purchaser Order No. Engineer Unit No. Model No. Unit Designation Performance Data Certified By: Packaged Gas/Electric with R-410A Standard Features

More information

Surge Arresters. Surge Arrester/Type L Fuse Cutout Combination. Description. Construction. Connectors/Brackets

Surge Arresters. Surge Arrester/Type L Fuse Cutout Combination. Description. Construction. Connectors/Brackets Surge Arresters Surge Arrester/Type L use ombination Electrical Apparatus 235-26 escription ooper Power Systems surge arrester/type L interchangeable fuse cutout combinations are available in a wide variety

More information

Distribution Arresters

Distribution Arresters Heavy Duty & Riser Pole Ÿ Tested to the latest IEEE C62.11 standards Ÿ High Strength Fiberglass Isolator Brackets Ÿ Ground Lead Disconnect will operate with a minimum of 1 amp Ÿ Protective Cap RUS APPROVED

More information

STUD WELDING EQUIPMENT & ACCESSORIES CATALOG NEWPOINT PLACE LAWRENCEVILLE, GA PHONE: (770) FAX: (770)

STUD WELDING EQUIPMENT & ACCESSORIES CATALOG NEWPOINT PLACE LAWRENCEVILLE, GA PHONE: (770) FAX: (770) STUD WELDING EQUIPMENT & ACCESSORIES CATALOG WWW.WELDSTUD.COM 4505 NEWPOINT PLACE LAWRENCEVILLE, GA 30043 PHONE: (770)-962-3657 FAX: (770)-962-3667 6/2008 FERRULE GRIPS CLOSED FERRULE GRIP (1 LONG) BRASS

More information

Large AC Motors. Synchronous Reluctance Kiln Duty Submersible Accessories & Kits. Large AC Motors. Modifications Large AC M-211

Large AC Motors. Synchronous Reluctance Kiln Duty Submersible Accessories & Kits. Large AC Motors. Modifications Large AC M-211 Synchronous Reluctance Kiln Duty Submersible Accessories & Kits Modifications Large AC M-211 large_ac_motors.fm Page 212 Monday, December 15, 2003 3:47 PM, Quickship and Modifiable 250 HP - 1500 HP 3600

More information

Products Catalogue Cable Lugs, Crimping Tools & Bus Bar

Products Catalogue Cable Lugs, Crimping Tools & Bus Bar Products Catalogue 2012 Cable Lugs, Crimping Tools & Bus Bar Railway series Lugs W/O Inspection Hole S b Ød 2 c 1 c 2 3D70-10 a Ød 1 Ød 3 J 3D Cat No. REF : I.C.F. d1 a b d2 d3 C1 C2 K J s 17 5 3D 5042

More information

~... INS_TR_UC_TI_ON_P_AM_PH_LE_T _U-5_81_6 --~ GENERAL PURPOSE ELECTRONIC WHEEL DETECTOR INSTALLATION AND MAINTENANCE (UN ) CONTENTS ...

~... INS_TR_UC_TI_ON_P_AM_PH_LE_T _U-5_81_6 --~ GENERAL PURPOSE ELECTRONIC WHEEL DETECTOR INSTALLATION AND MAINTENANCE (UN ) CONTENTS ... WABCC... NS_TR_UC_T_ON_P_AM_PH_LE_T _U-5_81_6 -- GENERAL PURPOSE ELECTRONC WHEEL DETECTOR NSTALLATON AND MANTENANCE (UN451062-0801) CONTENTS General.... Operating Characteristics nstallation Procedure

More information

BSM ROTARY GEAR PUMPS

BSM ROTARY GEAR PUMPS -SERIES FLG. MTD. PUMP PUMP FOOT The BSM -Series pumps are designed to provide quiet and efficient service at standard motor speeds, moderately high pressures. Typical applications are supplying hydraulic

More information

I nstallation I nstruction Heatshrink Term ination For 3 Core Polym eric Cables 7.2 kv to 3 6 kv

I nstallation I nstruction Heatshrink Term ination For 3 Core Polym eric Cables 7.2 kv to 3 6 kv I nstallation I nstruction Heatshrink Term ination For 3 Core Polym eric Cables 7.2 kv to 3 6 kv I NDOOR OUTDOOR ISSUE DATE: 05.01.11 General Fitting I nstructions * I t is highly recom m ended that a

More information

Cross Reference Chart CHARDON. PART NUMBER DESCRIPTION Elastimold Cooper Hubbell. Elastimold

Cross Reference Chart CHARDON. PART NUMBER DESCRIPTION Elastimold Cooper Hubbell. Elastimold Cross Reference Chart CHARDON Elastimold PART NUMBER DESCRIPTION Elastimold Cooper Hubbell 15/25-TB600 15/25 kv, 600A T-Body Connector w/o Test Point K655BLR BT625 625TB 15/25-TB600T 15/25 kv, 600A T-Body

More information

Bus bar Bushings up to 1.1kV and from 1.6kA to 4kA for Liquid Filled Transformers:

Bus bar Bushings up to 1.1kV and from 1.6kA to 4kA for Liquid Filled Transformers: 4 (Four) Pole Monoblock: Bus bar Bushings up to 1.1kV and from 1.6kA to 4kA for Liquid Filled Transformers: Designed and manufactured in accordance with EN 50336:2002 and BS 2562: 1979 1 Introduction:

More information

STUD WELDING EQUIPMENT & ACCESSORIES CATALOG

STUD WELDING EQUIPMENT & ACCESSORIES CATALOG STUD WELDING EQUIPMENT & ACCESSORIES CATALOG www.truweldstudwelding.com TWE@tfpcorp.com 6400 N. Honeytown Road Smithville, OH 44677 Phone: (330) 725 7744 Fax: (330) 669 2473 A Division of Tru Fit Products

More information

Stud Welding Products,Inc

Stud Welding Products,Inc Stud Welding Products,Inc ACCESSORIES CATALOG L 3-7/8 3- B-4N/B- 3/8 1-2- www.studweldprod.com Info@studweldprod.com.com Los Angeles, San Francisco, Phoenix, Seattle Phone: (800) 252-1919 Studs Since 1981

More information

Dimensions mm Dia. B Dia. C Dia. D Rad. E. Min F.L. kn SHLV1 SHLV2 SHLV

Dimensions mm Dia. B Dia. C Dia. D Rad. E. Min F.L. kn SHLV1 SHLV2 SHLV Shackle & Pin Porcelain LV E D E E Shackle ype SLV1 : SLV2 : SLV8 Pin ype LVLP at No. Dimensions Dia. Dia. Dia. D Rad. E hread Pin Min F.L. SLV1 SLV2 SLV8 LVLP 54 32 91 5 80 5 82 39 54 40 52 1 1 1 1 12

More information

Floodlighting Accessories

Floodlighting Accessories GLARE SHIELDS Catalog Approx. Number Item Wt. (lbs.) 6" (152) 75-GS ULTRA FLOOD GLARE SHIELD 2 Manufactured of corrosion-resistant aluminum. 75-VS For use with Ultra Flood, Series 75. Standard 14-3/4"

More information

GROUP C. Apparatus Bushing.

GROUP C. Apparatus Bushing. GROUP C Apparatus Bushing Tel : 82-31-420-6650~3 FAX : 82-31-424-7300 www.pyungil.com Epoxy Bushing for 25kV 630A APPARATUS BUSHING (125kV BIL) apparatus bushing K650P2 K650P2 will accept an elbow connectors

More information

DAQO Technical Differences of Isolated Phase Bus Standards. Study of Design Standard Variances, Insulator Design and Shipping Section Design

DAQO Technical Differences of Isolated Phase Bus Standards. Study of Design Standard Variances, Insulator Design and Shipping Section Design DAQO Technical Differences of Isolated Phase Bus Standards Study of Design Standard Variances, Insulator Design and Shipping Section Design Global Reference Medium Voltage Electrical Equipment Standards

More information

Priming Systems Installation Instructions

Priming Systems Installation Instructions Priming Systems Installation Instructions System Components: Single Priming Pump: Single VAP Valve Systems: Control Panel Activated... 2 Auto Prime (Pressure Switch) Activated... 3 Multiple VAP Valve Systems...

More information

CPCS the U.S.A.

CPCS the U.S.A. Clampsticks "AKA" Shotgun Sticks feature a high quality foam filled fiberglass reinforced plastic tube providing maximum insulation and mechanical strength. They are lightweight and easy to handle. Feature

More information

Kuhlman Electric Corporation Volt Instrument Transformers

Kuhlman Electric Corporation Volt Instrument Transformers Kuhlman Electric Corporation 34500 Volt Instrument Transformers 34500 Volt Table of Contents Description Model Page Wound, Dry-Type VT Y (High Accuracy available) PTT-200-9710(H) 3-4 Wound, Oil-Filled

More information

Grounding Solutions for Data Center Applications

Grounding Solutions for Data Center Applications Grounding Solutions for Data Center Applications B D A A C E G F E Legend For Typical Grounding Application (layout on following page) A) B) C) D) E) F) G) Vertical Rack Ground Bar Kit (see page 4) Horizontal

More information

Bulletin 1494V Variable Depth, Flange Operated Disconnect Switch Kits for 400 and 600 Amperes (Series A) Switches

Bulletin 1494V Variable Depth, Flange Operated Disconnect Switch Kits for 400 and 600 Amperes (Series A) Switches Bulletin 494V Variable Depth, Flange Operated Disconnect Switch Kits for and Amperes (Series A) Switches ATTENTION: To prevent electrical shock, disconnect from power source before installing or servicing.

More information

Easy-On II Terminations

Easy-On II Terminations Features Class 1 (outdoor) termination as defined in IEEE 48 standard. For use on all extruded dielectric cables, concentric neutral, metal tape shielded or wire shielded cables without need for additional

More information

Number Tube I.P.S. Rod Size or O.D. Range Cable H J W

Number Tube I.P.S. Rod Size or O.D. Range Cable H J W TYPE GAR D-28 FENCE POST GROUNDING CONNECTOR For Parallel or 90 Copper Cable Connection To Rod or Pipe with the Same Connector High copper alloy ground connector for joining a range of cable, parallel

More information

VG30DE(TT) Top-Feed Fuel Rail Kit (OE Injector Depth) revised 9/28/2014

VG30DE(TT) Top-Feed Fuel Rail Kit (OE Injector Depth) revised 9/28/2014 Parts List VG30DE(TT) Top-Feed Fuel Rail Kit (OE Injector Depth) revised 9/28/2014 (Qty) Description (2) Fuel Rail assembly (6) Viton o-ring injector cushions (13/16 OD) (8) ARP SS Upper plenum bolts w/washers

More information

I Surge Arresters. UltraSIL Polymer-Housed VariSTAR Type U3 Surge Arrester for Systems through 275 kv IEC 10 ka; Line Discharge Class 3 GENERAL

I Surge Arresters. UltraSIL Polymer-Housed VariSTAR Type U3 Surge Arrester for Systems through 275 kv IEC 10 ka; Line Discharge Class 3 GENERAL Surge Arresters UltraSIL Polymer-Housed VariSTAR Type U3 Surge Arrester for Systems through 275 kv IEC 10 ka; Line Discharge Class 3 Electrical Apparatus I235-93 GENERAL UltraSIL Polymer-Housed VariSTAR

More information

Driveline Components Catalog Small Parts

Driveline Components Catalog Small Parts Driveline Components Catalog Small Parts J300P-9 October 2016 Supersedes J300P-9 Dated December 2008 Our most comprehensive listing of Spicer small parts, including all the part numbers currently being

More information

Features and Application

Features and Application ML-DTL-83723 Series Features and Application Bayonet and Threaded Coupling Features and Application ML-DTL-83723 Series family offers connectors with bayonet and threaded coupling including lanyard-release

More information

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS Model MSA(4,6)BF Series M120 Product Line Extra High Efficiency Air Conditioner 16 SEER 2-5 Ton Capacity 2 The MSA(4,6)BF Series of Maytag air conditioners offers exceptional performance.

More information

SUBMERSIBLE SECONDARY CONNECTORS SSBC350-4LI. Cond. Range H W L

SUBMERSIBLE SECONDARY CONNECTORS SSBC350-4LI. Cond. Range H W L SUBMERSIBLE SECONDARY CONNECTORS -1- Index TYPE SSBC350-L (Wide-Port Spacing) Rubber Insulated Secondary Connectors SURE-SEAL RUS Approved User friendly wide-port spacing (50% more room for cable training).

More information

PARTS LIST FOR AIR COMPRESSOR/GENERATOR/WELDER AGW-SH22-20M

PARTS LIST FOR AIR COMPRESSOR/GENERATOR/WELDER AGW-SH22-20M PARTS LIST FOR AIR COMPRESSOR/GENERATOR/WELDER AGW-SH22-20M ENGINE: HONDA ENGINE OIL GRADE: SAE 10W-30 ENGINE OIL CAPACITY: 67.6 oz. MAXIMUM PRESSURE: COMPRESSOR OIL GRADE: COMPRESSOR OIL CAPACITY: 175

More information

1ZSE en, Rev. 7. Transformer bushings, type GOB Technical guide

1ZSE en, Rev. 7. Transformer bushings, type GOB Technical guide 1ZSE 2750-102 en, Rev. 7 Transformer bushings, type GOB Technical guide This Technical Guide has been produced to allow transformer manufacturers, and their designers and engineers, access to all the technical

More information