1 Product Index 2900 Sencore Drive, Suite 100 Sioux Falls, SD VT Packs : 2:1 VT Pack for use on any 480V service requiring three VTs. A : 2:1 VT Pack for use on 480 volt 3-wire delta applications having TWACS. Unit is fully ANSI compliant A : 4:1 VT Pack for use on 480 volt 3-wire delta applications. Unit is fully ANSI compliant : For use on 480/277 4-wire wye applications with solid-state meters. A : For use on any 480/277 volt application. Unit is fully ANSI compliant. Warranty VT Pack Limited Warranty Sockets, Blocks, and Adapters TS-SCH-1: TS-SCH-TR: TS-TR-L-1: TS-PTS-13: TS-ITH-1: Self-contained socket for use with Form 9S Class 200 meters Hunt Technologies external endpoint ready version of TS-SCH-1 Transformer-rated socket with lever bypass Transformer-rated socket with pre-wired test switch Small transformer-rated 13 terminal socket Wiring harnesses and accessories WH-STD-1: WH-AUX-1: WH-JP: 4-#10-TS-B: CK-ST-1: Wiring harness for transformer-rated applications Auxiliary harness for powering auxiliary devices on 3-wire Delta applications Jumper plug for use when socket is installed on non-480v applications Terminal strip and backer plate for terminating voltage inputs Kit for mounting VT Pack on outside of existing cabinet or socket 4824-Aux: 4824-Aux-Ext: 4812-Aux-Ext: Aux: Aux-Ext: Connector Cover 480/240 Auxiliary power transformer (internal mounting) 480/240 Auxiliary power transformer (internal or external mounting) 480:120 Auxiliary power transformer (internal or external mounting) 208/120 Auxiliary power transformer (internal mounting) 277V / 240V / 120V auxiliary power transformer (internal or internal mounting) Boot to protect connector and harness for external VT Pack applications Revised:
2 Catalog # : This VT Pack can be used on any 480V application. For 480/277 4-wire wye applications where traditional 2.5:1 VTs are used, we recommend our 2.5:1 VT Pack (Cat. # ). The VT Pack consists of three revenue-accuracy voltage transformers for use with modern wide voltage range electronic watthour meters. The transformers are encased in epoxy inside a UV-resistant polycarbonate enclosure. This VT Pack can be used with either standard transformer-rated solid-state meters or the new Form 9S, Class 200 solid state polyphase meter. The connector on the VT Pack mates with the wiring harness of our sockets or block assemblies. For existing transformer-rated applications, a color-coded wiring harness is available either with our standard color code or can be supplied in custom color-coding and lengths to meet your Company s requirements. The VT Pack can be mounted in a pad mount transformer, transformer cabinet, on the outside of an existing meter socket, or other convenient location. The keyhole slot on the VT Pack makes mounting on any 1/4 mounting screw or shoulder rivet quick and easy. Shipping weight: 12 pounds Dimensions: 12 3/16 long by 4 wide by 3 1/16 deep with 2 1/4 wide / 1 deep collar Accuracy: +/- PF lag Thermal rating: 30 degrees C, 55 degrees Insulation level: 10 kv BIL Overvoltage withstand: 960V for 1 minute Revised
3 Catalog # : This VT Pack is for 480/277 4-wire wye applications where traditional 2.5:1 VTs are used. For all other 480V applications, we recommend our 2:1 VT Pack (Cat. # ) The VT Pack consists of three revenue-accuracy toroidal voltage transformers for use with modern wide voltage range electronic watthour meters. The transformers are encased in epoxy inside a UV-resistant polycarbonate enclosure. This VT Pack can be used with either standard transformer-rated solid-state meters or the new Form 9S, Class 200 solid state polyphase meter. The connector on the VT Pack mates with the wiring harness of our sockets or block assemblies. For existing transformer-rated applications, a color-coded wiring harness is available either with our standard color code or can be supplied in custom color-coding and lengths to meet your Company s requirements. The VT Pack can be mounted in a pad mount transformer, transformer cabinet, on the outside of an existing meter socket, or other convenient location. The keyhole slot on the VT Pack makes mounting on any 1/4 mounting screw or shoulder rivet quick and easy. Shipping weight: 12 pounds Dimensions: 12 3/16 long by 4 wide by 3 1/16 deep with 2 1/4 wide / 1 deep collar Accuracy: +/- PF lag Thermal rating: 30 degrees C, 55 degrees C Insulation level: 10 kv BIL Overvoltage withstand: 600V for 1 minute Revised
4 Catalog # : A This VT Pack is for 480/277 4-wire wye applications where traditional 2.5:1 VTs are used. For all other 480V applications, we recommend other versions see catalog for various options. This VT Pack consists of three revenue-accuracy toroidal voltage transformers for use with modern wide voltage range electronic watthour meters or older induction (disk-type) meters. The transformers are encased in epoxy inside a UV-resistant polycarbonate enclosure. This VT Pack can be used with either standard transformer-rated meters or the Form 9S, Class 200 solid state polyphase meter. The connector on the VT Pack mates with the wiring harness of our sockets or block assemblies. For existing transformer-rated applications, a color-coded wiring harness is available either with our standard color code or can be supplied in custom color-coding and lengths to meet your Company s requirements. The VT Pack can be mounted in a pad mount transformer, transformer cabinet, on the outside of an existing meter socket, or other convenient location. The keyhole slot on the VT Pack makes mounting on any 1/4 mounting screw or shoulder rivet quick and easy. The VT Pack can also be mounted on a cross arm, pole or other suitable outdoor location when used with the optional Connector Cover. Shipping weight: 14 pounds Dimensions: 12 3/16 long by 4 wide by 3 1/16 deep with 2 1/4 wide / 1 deep collar Accuracy: +/- PF lag (W) Thermal rating: 30 degrees C, 55 degrees C Insulation level: 10 kv BIL Overvoltage withstand: 600V for 1 minute Revised
5 Catalog #: A This fully ANSI compliant two transformer VT Pack with a ratio of 2:1 is designed to be used on 480V three wire delta applications where a 240 volt secondary is required. This VT Pack consists of two revenue-accuracy voltage transformers and are encased in epoxy inside a UVresistant polycarbonate enclosure. This VT Pack can be used with either induction (disk type), solid-state fixed voltage, wide voltage range solid-state, or a Form 9S, Class 200 solid state wide voltage range polyphase meter. The connector on the VT Pack mates with the wiring harness of our sockets or block assemblies. For conventional transformer-rated applications, a color-coded wiring harness is available with either our standard 6 foot harness or custom wire color-coding and lengths to meet your Company s requirements. With minimum order requirements, we can even print color names or other information on the conductors. The VT Pack can be mounted in a pad mount transformer, transformer cabinet, on the outside of an existing meter socket, or other convenient location. The keyhole slot on the VT Pack makes mounting on any 1/4 mounting screw or shoulder rivet quick and easy. The VT Pack can also be mounted on a cross arm, pole or other suitable outdoor location when used with the optional Connector Cover. Shipping weight: 12 pounds Dimensions: 12 3/16 long by 4 wide by 3 1/16 deep with 2 1/4 wide / 1 deep collar Accuracy: 12.5 PF lag (W) Thermal rating: degrees C, degrees C Insulation level: 10 kv BIL Over voltage withstand: 960V for 1 minute 2900 Sencore Drive, Suite 100, Sioux Falls, SD 57107; Phone: ; Fax: ; info@socket-two-me.com; WEB: socket-two-me.com Revised
6 Limited Warranty Two Sockets-Two Meters, Inc. (TS) offers a limited warranty on its VT Packs subject to the following conditions: TS warrants its VT Packs against defects in materials, workmanship, and certain field hazards for a period of five (5) years from the date of proper installation or six (6) years from date of manufacture, whichever comes first. This warranty is not applicable outside the United States or Canada unless specifically authorized in writing. In order to qualify for this limited warranty, the VT Pack must be installed according to TS s installation instructions and application guide. In the event a covered claim arises under this limited warranty, TS shall, at its sole discretion, either (a) replace the defective/damaged VT Pack or (b) reimburse the purchase price associated with the defective/damaged VT Pack. In no event shall TS be responsible for installation, mileage, or other change-out costs. THIS WARRANTY SETS FORTH TS'S MAXIMUM LIABILITY FOR ITS PRODUCTS. TS SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, CONSEQUENTIAL OR INCIDENTAL DAMAGES. YOUR EXCLUSIVE REMEDY WITH RESPECT TO ANY AND ALL LOSSES OR DAMAGES RESULTING FROM ANY CAUSE WHATSOEVER SHALL BE AS SPECIFIED HEREIN. TS SHALL NOT BE LIABLE FOR ANY CONSEQUENTIAL OR INCIDENTAL DAMAGES OF ANY KIND, HOWEVER OCCASIONED, WHETHER BY NEGLIGENCE OR OTHERWISE. TS MAKES NO OTHER WARRANTY OR GUARANTEE, EITHER EXPRESS OR IMPLIED, INCLUDING IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. TS DOES NOT AUTHORIZE ANY OTHER PARTY TO MAKE A WARRANTY OF ANY KIND ON ITS BEHALF AND THE PURCHASER OF TS'S PRODUCTS SHOULD NOT RELY ON ANYONE MAKING ANY SUCH WARRANTY. (over) D:\Shared\Greg\Word\Limited Warranty R5.doc
7 Additional Exclusions: Improper application Use of the VT Pack on burdens and voltages that exceed the nameplate ratings and specifications. Failure of a 2:1 VT Pack on 480 volt three wire delta applications as the result of the ungrounded wye-delta phenomena and/or ferro-resonance IS warranted. In addition, either the 2:1 or the 2.5:1 VT Pack IS warranted due to failures caused by lightning. Flooding Submersion in water or water based liquid while energized. Submersion in saltwater or seawater at anytime. Improper wiring Including reversal of primary and secondary connections Vandalism Including damage to externally mounted units caused by livestock Physical damage Including impact with moving vehicles and structural collapse This limited warranty only covers products shipped or thereafter. Limited warranty terms and conditions are subject to change without notice. All warranty claims must be submitted in writing within the limited warranty period to Two Sockets-Two-Meters Inc., for approval, at 2900 West Sencore Drive, Suite 100, Sioux Falls, South Dakota The following information must be submitted with the warranty claim: Name and address of claimant, product serial number, date of purchase, date defect/damage was discovered, and description of defect/damage. TS will advise the claimant, within a reasonable time, of its position with respect to the warranty claim. In the event a VT Pack is to be returned to TS under this limited warranty, the VT Pack returned must be suitably packed and shipped. The claimant will be responsible for paying the cost of transporting the VT Pack to TS. Upon receipt of the VT Pack, TS will replace the defective/damaged VT Pack, return shipping prepaid and allowed, or refund the purchase price of the defective/damaged VT Pack, if found to be covered under the terms of this limited warranty. Upon request, any defective/damaged VT Pack that has been returned to TS as a warranty claim will be returned by TS, to the purchaser, freight prepaid and allowed, within a reasonable time after it is received from the claimant. D:\Shared\Greg\Word\Limited Warranty R5.doc
8 Catalog # : TS-SCH-1 This meter cabinet is designed for the Form 9S Class 200 solid-state meter. By installing the appropriate application jack (located between the VT Pack and the neutral connector), this socket can be configured for 3-wire or 4-wire services. The KYZ terminals on the socket block are also brought out to a separate terminal strip for easy installation of AMR devices or other applications requiring a pulse initiator. Shipping weight: 28 pounds (w/o VT Pack)
9 Catalog # : TS-TR-L-1 Proven Siemens lever bypass, jaw release type HQ-13T block assembly for safe and reliable shorting of CT secondaries for meter removal. Insulated, effectively dead front, 600V, four pole terminal strip for easy termination of voltage inputs. No need to access a distribution transformer s secondary to troubleshoot the metering installation. Pre-wired, color-coded wire harness with connector minimizes the likelihood of wiring errors. AMR-ready design makes field installation quick and easy. Compact pre-wired design eliminates need for VT mounting brackets, expensive transformer cabinets, and wiring of VTs. VT Pack is optional; refer to photos and captions for details. Dimensions: 5 x 16 x 20 inches Shipping weight: 24 pounds (w/o VT Pack) Optional # (2.5:1) VT Packs: # (2:1)
10 Catalog # : TS-PTS-13 TS-PTS-13 with WH-JP jumper plug installed (non-480v applications) TS-PTS-13 with 2.5:1 VT Pack installed (480/277V 4-wire wye applications). For 480V 3-wire and 480/240 4-wire, use 2:1 VT Pack. Insulated 600V, four pole terminal strip for easy termination of voltage inputs. No need to access a distribution transformer s secondary to troubleshoot the metering installation. Pre-wired, color-coded wire harness with connector minimizes the likelihood of wiring errors. Custom test switch configuration, color coding, test switch cover, and other options are available for larger requirements. Wiring from top of test switches to the block assembly is pre-wired, further minimizing potential wiring errors and reducing installation time. AMR-ready design makes field installation quick and easy. Compact pre-wired design eliminates need for VT mounting brackets, expensive transformer cabinets, and wiring of VTs. VT Pack is optional; refer to photos and captions for details. Dimensions: 5 x 16 x 20 inches Shipping weight: 25 pounds (w/o VT Pack) Optional # (2.5:1) VT Packs: # (2:1)
11 Catalog # : TS-ITH-1 Proven Siemens lever bypass, jaw release type HQ-13T block assembly for safe and reliable shorting of CT secondaries for meter removal. This socket is for applications where it is desirable to mount the VT Pack separately, or locations where space may not permit mounting one of our other transformer-rated meter sockets (pad-mount installations, for example). Shipping weight: 20 pounds
12 Catalog # : 12S-480:120-6/9-2 Adapter interior showing jaws in both the 6 o clock and 9 o clock positions. Adapter base shown with 5 th terminal in the 6 o clock position. Adapter is available with the 5 th terminal in either the 6 o clock or 9 o clock position as it is field changeable. This adapter is designed to work with a modified Form 12S GE kv2c+ meter to enable any under-glass AMR device to be powered at a reduced 120 volts instead of the 480 volt service voltage. Reduced voltage is accomplished by the use of a field proven 200 VA 480:120 volt toroidal autotransformer housed in the adapter body. Shipping weight: 5 pounds Patent Applied for Revised
13 Catalog # : WH-STD-X This harness is used for external mounting of the VT Pack in transformer-rated applications and is available in our standard 6-foot, 12- foot, or 20 foot lengths and color code. For ordering, replace X in catalog number with either 6, 12, or 20 to denote length. The harness can also be custom made to any length or color code to conform to your Company's requirements. However, if the desired length exceeds 20 feet, we recommend our #4-#10-TS-B Block Assembly to extend either the primary or the secondary. Shipping weight: 1-3 pounds, depending on length.
14 Catalog # : WH-AUX-1 This auxiliary power harness is used where it is necessary to provide power to a Turtle transmitter or other auxiliary device when the socket is used on 480-volt, 3-wire delta applications. This is accomplished by accessing the third, unused VT, not required for 3-wire delta applications. Power supplied through this harness is drawn from the VT Pack s secondary, and is therefore limited to 125VA. Shipping weight: 1 pound
15 Catalog # : WH-JP This jumper plug is used in place of the VT Pack only when installing one of our sockets in non-480v applications. Shipping weight: 1 pound
16 Catalog # : 4-#10-TS-B This insulated 600V, 4-pole terminal block and backer strip assembly is the same as the one used in our TS-TR-L-1 and TS-PTS-13 sockets and is for installation into existing transformer-rated sockets or where alternate mounting of the terminal block is desired. A pair of self-drilling Phillips screws is supplied to aid in installation. Shipping weight: 1 pound
17 Catalog # : CK-ST-1 This kit contains all the needed hardware to mount a VT Pack on the outside of an existing meter socket through a 2 knockout or punched hole: 1 foam gasket (fits around collar on VT Pack) 4 self-drilling screws for mounting VT Pack 2 screw seals to prevent unauthorized removal of VT Pack 4 vinyl caps to cover self-drilling screw ends inside socket Shipping weight: 1 pound
18 Catalog # : 4824-Aux * 4824-Aux not intended for use as a revenue metering VT. Ratio: 2:1 (480:240 volts) Primary Voltage: volts Over voltage withstand: 900 volts for 1 minute VA rating: C; C BIL: 10kV Dimensions: Diameter: 3.5 inches Height: 2.6 inches Lead lengths: 24 inches Lead wire size: # 14 stranded Weight: ~ 3 pounds Mounting: Internal Limited Warranty: 5 years from date of installation.** This transformer is designed to provide auxiliary power where the application is 480V 3- wire delta. Applications include, but are not limited to, under-glass TWACS transmitters or external three-phase Turtle transmitters. This transformer is identical in its basic design* to the ones used in our 2:1 VT Pack (Cat.# ). The 4824-Aux provides the same protection against failure of the TWACS transmitter or the Turtle transmitter as the VT Pack provides against failure of the new wide voltage range solid state meters. For external mounting, see: Cat.# 4824-Aux-Ext. Shipping weight: 4 Pounds
19 Catalog # : 4824-Aux-Ext Ratio: 2:1 (480:240 volts) Primary Voltage: volts Over voltage withstand: 900 volts for 1 minute VA rating: C; C BIL: 10kV Dimensions: Diameter: 3.5 inches Height: 2.6 inches Lead lengths: 24 inches Lead wire size: # 14 stranded Weight: ~ 3 pounds Mounting: External or internal Limited Warranty: 5 years from date of installation.** This transformer is designed to provide auxiliary power where the application is 480V 3- wire delta. Applications include, but are not limited to, under-glass TWACS transmitters or external three-phase Turtle transmitters. This transformer is identical in its basic design* to the ones used in our 2:1 VT Pack (Cat.# ). The 4824-Aux provides the same protection against failure of the TWACS transmitter or the Turtle transmitter as the VT Pack provides against failure of the new wide voltage range solid state meters. For applications where the transformer is to be inside the socket, see: Cat.# 4824-Aux. Shipping weight: 4 Pounds
20 Catalog # : 4812-Aux-Ext Ratio: 4:1 (480:120 volts) Primary Voltage: volts Over voltage withstand: 900 volts for 15 seconds VA rating: C; C BIL: 10kV Dimensions: Diameter: ~ 4 inches Height: ~ 3 inches Lead length: 24 inches Lead wire size: # 14 stranded Weight: ~ 5 pounds Mounting: External or internal Limited Warranty: 5 years from date of installation (Contact Two Sockets-Two Meters, Inc. for warranty details). This transformer is designed to provide auxiliary power where the application is 480V 3- wire delta. Applications include, but are not limited to, under-glass TWACS transmitters or Hunt Technologies internal or external TS1 or TS2 endpoints. This transformer is identical in its basic design to the ones used in our 4:1 VT Pack (Cat.# A ). The 4812-Aux-Ext provides the same protection against failure of the TWACS or Hunt Technologies endpoints as the VT Pack provides against failure of the new wide voltage range solid state meters. Shipping weight: 6 Pounds Revised
21 Catalog # : 277/240/120-Aux-Ext 277V 240V 120V * 277/240/120-Aux-Ext not intended for use as a revenue metering VT. Ratio: Variable depending on connection Primary Voltage: 277, 240, or 120 volts VA rating: C; C BIL: 10kV Dimensions: Diameter: 3.5 inches Height: 2.6 inches Lead length: 24 inches Specifications 277 / 240 / 120 Autotransformer Lead wire size: # 14 stranded Weight: ~ 3 pounds Mounting: Internal or External not UV resistant Limited Warranty: 5 years from date of installation. (Contact Two Sockets-Two Meters, Inc. for warranty details.) Shipping weight: 4 pounds This transformer is designed to provide a combination of voltages for a variety of applications. For example: With 120V input, 240V or 277V is available With 240V input, 120V or 277V is available. With 277V input, 120V or 240V is available. Applications for this transformer include but are not limited to SCADA, load management, modems or AMR devices. The 277/240/120-Aux-Ext is similar in its basic design* to the ones used in our 2:1 VT Pack ( ) and provides the same protection against failure of the equipment as the VT Pack provides against failure of the new wide voltage range solid state meters. Note: Once installed, the unused lead MUST be taped off or otherwise isolated! Revised
22 Catalog # : Aux * Aux not intended for use as a revenue metering VT. Ratio: 1.73:1 (208:120 volts) Primary Voltage: 208 volts VA rating: C; C BIL: 10kV Dimensions: Diameter: 2.7 inches Height: 1.4 inches Lead lengths: 24 inches Lead wire size: # 16 stranded Specifications 208:120V Auto Transformer Weight: ~ 2 pounds Mounting: Internal Limited Warranty: 5 years from date of installation.** ** Contact Two Sockets-Two Meters, Inc. for warranty details. This transformer is designed to provide auxiliary power to a 208V or 240V external threephase Turtle transmitter where the transmitter would normally be connected phase-tophase on a 208/120 network, 208/120 4-wire Y, or a 240/120 4-wire delta service. Using this transformer allows the transmitter to use only one phase resulting in a much stronger signal sent to the receiver. This transformer is identical in its basic design* to the ones used in our 2:1 VT Pack (Cat.# ). The Aux provides the same protection against failure of the Turtle transmitter as the VT Pack provides against failure of the new wide voltage range solid state meters. Shipping weight: 3 Pounds
23 Catalog #: Connector Cover The Connector Cover is a UV resistant boot made with LTV-9400 material, specifically designed for high voltage outdoor wildlife guards to provide protection when the VT Pack is externally mounted such that the connector and harness would otherwise be exposed to the elements. To provide security we recommend that one uses a very small amount of Gorilla Glue to secure the cover to the VT Pack collar. Shipping weight: 1 lb. Revised
II DISTRIBUTION & SUBSTATION TYPE C
CapCheckIII DISTRIBUTION & SUBSTATION TYPE Ca p a c i t o r C h e c ke r Operating & Instruction Manual 1475 Lakeside Drive Waukegan, Illinois 60085 U.S.A. 847.473.4980 f a x 8 4 7. 4 7 3. 4 9 8 1 w e
More informationAD-7 THERMAL INDICATING AMMETER
AD-7 THERMAL INDICATING AMMETER a nd ACCESSORIES Operating & Instruction Manual HD ELECTRIC COMPANY 1 4 7 5 L A K E S I D E D R I V E W A U K E G A N, I L L I N O I S 6 0 0 8 5 U. S. A. P H O N E 8 4 7.
More informationHIGH VOLTAGE DIGITAL AMMETER
HIGH VOLTAGE DIGITAL AMMETER Operating & Instruction Manual HVA-2000 Making the Invisible Visible TM 1475 Lakeside Drive Waukegan, Illinois 60085 U.S.A. 847.473.4980 f a x 8 4 7. 4 7 3. 4 9 8 1 w e b s
More informationSafety Sentry Electronic Breakaway Switch
Safety Sentry Electronic Breakaway Switch P-616-WE 819-0454 Installation Instructions An Altra Industrial Motion Company Parts List Mounting hardware included with the Safety Sentry Breakaway Switch kit:
More informationLED Auxiliary Devices
LED Auxiliary Devices 30 YEARS OF EXCELLENCE 1985-2015 Incorporated in the state of California in 1985, McWong International, Inc. has grown to become a strategic supplier of high-quality lighting control
More informationMANUAL NO CREATED: 08/08/2012 MMH REV A STEEL COMPANY R 65 BUSHEL MINI-BIN PARTS AND ASSEMBLY MANUAL
MANUAL NO. 195988 CREATED: 08/08/2012 MMH REV A STEEL COMPANY R 65 BUSHEL MINI-BIN PARTS AND ASSEMBLY MANUAL TABLE OF CONTENTS SAFETY AND STATEMENTS OF IMPORTANCE... 2 GENERAL INFORMATION... 3 ASSEMBLY
More informationUtility Controller Hand Air Operated
Utility Controller Hand Air Operated P-1395 819-0288 Installation Instructions Introduction The Warner Electric air/manual Utility Controller combines manual and automatic (air) actuation for the operation
More informationMAINFRAME HOT RUNNER TEMPERATURE CONTROL SYSTEMS. Instruction Manual
MAINFRAME HOT RUNNER TEMPERATURE CONTROL SYSTEMS Instruction Manual Copyright, Athena Controls, Inc., 2006 Printed in USA CompuStep is a registered trademark of Athena Controls, Inc. SafeChange is a trademark
More informationSPORT COIL SPRINGS Scion xa & xb Part #19412 INSTALLATION OF HOTCHKIS FRONT COIL SPRINGS
SPORT COIL SPRINGS 2004+ Scion xa & xb Part #19412 Thank you for your purchase from our new line of Scion xa / xb parts. Please call us at (877) 4NO-ROLL if you have any questions regarding the service
More informationAGM. I-Lux MR 16 Style 2 & 5, Coil & Shunt. 108 Fairgrounds Drive Suite 8 Manlius, NY Phone: Fax:
AGM I-Lux MR 16 Style 2 & 5, Coil & Shunt Revision 7.5 Pg 2 I-Lux Catalog / Item Numbers Catalog Code XXX.XXF Sign Size 1 ~ Size 1 2 ~ Size 2 3 ~ Size 3 5 ~ Size 5 Sign Style 2 ~ Style 2 (3 step 4.8A -
More informationPro-Series/ Electromechanical Linear Actuator
Pro-Series/ Electromechanical Linear Actuator Installation and Operation Manual P-264-PROSERIES (08/10) Keep all product manuals as a product component during the life span of the product. Pass all product
More informationINSTRUCTION MANUAL. Rotary Unidirectional Piezoelectric Motor Evaluation Kit. (Model: UPM-28) Made in USA
www.dtimotors.com INSTRUCTION MANUAL Rotary Unidirectional Piezoelectric Motor Evaluation Kit (Model: UPM-28) Made in USA Rev. 6/2/2017 Table of Contents 1.0 Introduction... 2 2.0 Properties... 3 3.0 Unpacking
More informationTRINETICS CSD SERIES OIL SWITCH INSTALLATION INSTRUCTIONS
TRINETICS CSD SERIES OIL SWITCH INSTALLATION INSTRUCTIONS 33220900 DECEMBER 2011 Caution: The equipment covered by these installation instructions should be installed and serviced only by properly trained
More informationSUPREME FEEDER MANUAL NO REV A / 09/02/ DOOR HOG FEEDER ASSEMBLY INSTRUCTIONS
STEEL COMPANY R SUPREME FEEDER MANUAL NO. 166156 REV A / 09/02/2009 12 DOOR HOG FEEDER ASSEMBLY INSTRUCTIONS This feeder is designed for feeding an average hog from about 40 pounds up to about 250 pounds.
More informationFCB-450, LCB-600, MCB-800
AIR CHAMP PRODUCTS User Manual FCB-450, LCB-600, MCB-800 Clutch-Brakes (i) In accordance with Nexen s established policy of constant product improvement, the specifications contained in this manual are
More informationCBC-802 Plug-In Clutch/Brake Control with Solid State Switching
DIST. AUTORIZADO Plug-In Clutch/Brake Control with Solid State Switching P-29-5 19-0409 Service & Installation Instructions An Altra Industrial Motion Company DIST. AUTORIZADO Brake (Red) and clutch (Green)
More informationInstruction Sheet. SFR Series. Swing Frame rack
Instruction Sheet SFR Series Swing Frame rack THANK YOU Thank you for purchasing the SFR Series Swing Frame Rack. Please read these instructions thoroughly before installing/assembling this product. PRODUCT
More informationPVI 1800/PVI Residential/Commercial Grid-Tied Photovoltaic Inverter WARRANTY MANUAL. Subject to Change REV , Solectria Renewables
PVI 1800/PVI 2500 WARRANTY MANUAL Residential/Commercial Grid-Tied Photovoltaic Inverter 2009, Solectria Renewables Subject to Change REV 10.09 1 Product Warranty & RMA Policy 1.1 Warranty Policy The Solectria
More information10 Year Limited Warranty
Power. On Your Terms. 10 Year Limited Warranty PHI 2.7 TM PHI 3.5 TM 60A SIMPLIPHI POWER, INC. REV020618 10 Year Limited Warranty: PHI 2.7 TM PHI 3.5 TM 60A 24V 48V Limited Pro-Rated Warranty Coverage
More informationSUNTURA SOLAR TRACKER
WindyNation SUNTURA SOLAR TRACKER SOT-TRKS-NF User s Manual Page 1 of 10 WindyNation 08/09/2012 Table of Contents 1 Introduction... 3 1.1 Limited Warranty... 3 1.2 Restrictions... 3 1.3 Warranty Claims
More informationCUSTOMER SERVICE: 800-973-8374 Frame Assembly Instructions Headboard Installation E 1. Use the remote control to raise the head of the adjustable foundation in order to gain access to the foundation
More informationPVI 60KW, PVI 82KW, PVI 95KW
PVI 60KW PVI 82KW PVI 95KW WARRANTY MANUAL Commercial, Grid-Tied Photovoltaic Inverters 2008, Solectria Renewables LLC Subject to Change DOC-020099 rev 024 1 1 Product Warranty & RMA Policy Warranty Policy
More informationInstallation & Operation Manual. Electrak 100 Series / Electromechanical Linear Actuator
www..c Installation & Operation Manual Electrak 100 Series / Electromechanical Linear Actuator Thomson has many years of experience designing and manufacturing linear actuators for a wide variety of applications
More informationHBC-20 - LED HIGH BAY
To prevent death, injury or damage to property, this product must be installed in accordance to National Electrical Code (NFPA70) in the US or Canadian Electrical Code (CSA.) in Canada. Risk of fire or
More informationDM1016S INSTALLATION/OWNER'S MANUAL 10" Marine DVC Subwoofer
DM1016S INSTALLATION/OWNER'S MANUAL 10" Marine DVC Subwoofer DM1016S INSTALLATION Preparation/Installation Please read entire manual before installation. Before You Start Disconnect negative battery terminal.
More informationEZ-R7 T-Plug. Universal 7-Pin Heavy Duty Plug For Vehicles equipped with 7-Way Trailer Connectors. Installation Instructions and Product Warranty
EZ-R7 T-Plug Universal 7-Pin Heavy Duty Plug For Vehicles equipped with 7-Way Trailer Connectors Installation Instructions and Product Warranty Professional Installation Required Thank you for purchasing
More informationi400s Calibration Information Introduction
i400s AC Current Clamp Introduction XWWarning To avoid electric shock or injury, do not perform the performance tests or calibration procedures unless you are qualified to do so. The information provided
More informationSUNTURA HD SOLAR TRACKER
WindyNation SUNTURA HD SOLAR TRACKER SOT-TRKS-NFHD User s Manual Page 1 of 11 WindyNation 08/09/2012 Table of Contents 1! Introduction... 3! 1.1! Limited Warranty... 3! 1.2! Restrictions... 3! 1.3! Warranty
More informationRANGE HOODS USER INSTRUCTIONS
RANGE HOODS USER INSTRUCTIONS Model: Advanta Pro III 30 & 36 IMPORTANT SAFETY INSTRUCTIONS Carefully read the following important information regarding installation safety and maintenance. Keep these instructions
More informationFranklin Fueling Systems
Submersible Pumping and Fuel Management Systems Limited Warranty - FE Petro and INCON Fueling Systems Limited Warranties. 90-Day Warranty Coverage (Applicable Only to Tank Gauge Software, OEM Equipment
More informationRig Master Power by Mobile Thermo Systems Inc.
RigMaster Power Dealer Warranty Policy The Limited Warranty This limited warranty applies to the RigMaster Auxiliary Power Unit (RigMaster APU) which consists of the following components: 1. The generator
More informationGORE TRAILER MANUFACTURING INCORPORATED 305 Gore Trailer Road Whiteville, North Carolina 28472
(Revised September, 2005) GORE TRAILER MANUFACTURING INCORPORATED 305 Gore Trailer Road Whiteville, North Carolina 28472 WARRANTY TEN YEAR WARRANTY Subject to the requirements, exclusions and limitations
More informationInstruction Sheet DWRSR-ZL. Zero Clearance Latch
Instruction Sheet DWRSR-ZL Zero Clearance Latch US Patent 7,188,570 B2 THANK YOU Thank you for purchasing the DWRSR-ZL Zero Clearance Latch. Please read these instructions thoroughly before installing
More informationPower. On Your Terms.
Power. On Your Terms. 10 YEAR LIMITED WARRANTY PHI 1310 TM 1 SIMPLIPHI POWER, INC. REV102016 10 YEAR LIMITED WARRANTY: PHI 1310 TM LIMITED PRO-RATED WARRANTY COVERAGE The SimpliPhi Power PHI 1310 as supplied
More informationTiller Lock Assembly
2 1 4 1 2 4 1 2 4 1 7 6 7 8 Positioning Pin Assembly 1 Positioning Pin 2 Spring Black Knob 5 4 1 2 2 1 Tiller Lock Assembly 1 2 4 Threaded Rod Rotating Rod Spring Flat Washer 5 6 7 8 C Type Plastic Washer
More informationAir Curtain. Installation, Operating and Maintenance Instructions
Installation, Operating and Maintenance Instructions Save this manual for future reference. Air Curtain Model Numbers: ES026, ES036, ES042, ES048, ES060, ES072 READ THIS OWNER S MANUAL CAREFULLY BEFORE
More information24/3000H-3PH 24/4500H-3PH 24/6000H-3PH
Manufacturer of Dimensions TM Inverters 4467 White Bear Parkway St. Paul, MN 55110 Phone: 651-653-7000 Fax: 651-653-7600 E-mail: inverterinfo@sensata.com Web: www.dimensions.sensata.com 120015D OWNERS
More informationMaxLite LED Enclosed & Sealed Jelly Jars
General Safety Information To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/abrasions, and other hazards read all warnings and instructions
More information12 Volt Utility Controller for 4, 6 or 8 Brakes No P
12 Volt Utility Controller for 4, 6 or 8 Brakes No. 1300-77 P-1379 819-0094 Installation Instructions Introduction The Warner Electric manually operated Utility Controller operates 4, 6, or 8 twelve-volt
More informationDIGITAL EARTH RESISTANCE Model KM 2030
An ISO 9001:2008 Company GENERAL SPECIFICATIONS : DIGITAL EARTH RESISTANCE Model KM 2030 Display : 3½ Digit LCD display. Ground resistance measurements from 0 ~ 01Ω to 2000Ω with 0.01Ω resolution. Earth
More informationV2M1200/1290 Series Maglock Installation Instructions
Securitron Phoenix, AZ 85044 Tel: 1-800-624-5625 Mon-Fri: 6:00am - 4:00pm PDT Fax: 1-800-232-7329 www.securitron.com V2M1200/1290 Series Maglock Installation Instructions 1 Table of Contents Product Information...
More informationStraight-Bore Clutch LSCC-32, 44, 54
Straight-Bore Clutch LSCC-32, 44, 54 1 In accordance with Nexen s established policy of constant product improvement, the specifications contained in this manual are subject to change without notice. Technical
More information½ DODGE CUMMINS OEM BYPASS LIFT PUMP KIT Installation Instructions Part #
29 July 2005 2003-04.5 Dodge Cummins OEM Bypass Lift Pump Kit # 1050227-1 - 2003-04½ DODGE CUMMINS OEM BYPASS LIFT PUMP KIT Installation Instructions Part # 1050227 PLEASE READ ALL INSTRUCTIONS CAREFULLY
More informationCBC-802 Plug-In Clutch/Brake Control with Solid State Switching
CBC-02 Plug-In Clutch/Brake Control with Solid State Switching P-2104-WE 19-054 Service & Installation Instructions An Altra Industrial Motion Company Brake (Red) and clutch (Green) indicator lights When
More informationThree-Phase Pole Mounted Recloser
Three-Phase Pole Mounted Recloser Page 1 of 8 Table of Contents 1 GENERAL... 3 2 CONSTRUCTION... 3-5 3 BUSHINGS... 5 4 LINE CONNECTOR... 5 5 TOOLS....5 6 NAMEPLATES..6 7 PAINT... 6 8 EXTERNAL HARDWARE
More informationHPx-JDx3-xx HARNESS INSTALLATION
HPx-JDx3-xx HARNESS INSTALLATION Conversion Manual 09040106b HEADSIGHT.COM 574.546.5022 About Headsight Headsight Contact Info Headsight, Inc. 4845 3B Road Bremen, IN 46506 Phone: 574-546-5022 Fax: 574-546-5760
More informationInstruction Manual. Model HC1 Series Electrodless Conductivity Sensors
Instruction Manual Anderson Instrument Co. Inc. 156 Auriesville Road Fultonville, NY 12072 1-800-833-0081 Fax 518-922-8997 www.anderson-negele.com Instrument Model Number Instrument Serial Number Model
More informationLIGHTSTICK / LIGHTSTICK PLUS Germicidal Ultraviolet Light
LIGHTSTICK / LIGHTSTICK PLUS Germicidal Ultraviolet Light Installation & Operation Manual This manual covers the following models: LightStick #19300 LightStick Plus #19301 GENERAL This product emits germicidal
More informationELECTRONIC FIREPLACE DAMPER
ELECTRONIC FIREPLACE DAMPER Model: FSE Low Profile Series The Flue Sentinel Electronic Fireplace Damper is designed to increase the comfort and energy efficiency of residential homes with gas-fired fireplaces.
More informationDC to AC Power Inverters
Manufacturer of Dimensions TM Inverters 4467 White Bear Parkway St. Paul, MN 55110 Phone: 651-653-7000 Fax: 651-653-7600 E-mail: inverterinfo@sensata.com Web: www.dimensions.sensata.com ISO 9001:2000 Certified
More informationMEX (55) QRO (442) Web Controls
Web Controls SINGLE AND DUAL ROTOR TENSION CONTROL BRAKES MODELS:,,,, AND INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS Read this manual carefully, making full use of its explanations and instructions.
More information24V Solar Charger. Instructions READ CAREFULLY Garrymore Ln Missoula, MT
24V Solar Charger 9889 Garrymore Ln Missoula, MT 59808 888-687-3552 +1-406-549-0769 www.aquacreek.com Instructions PART #: F-045SCH (For use with Revolution, Scout, Titan, Spa Lift Ultra and Spa Lift Elite)
More informationDC to AC Power Inverters
Manufacturer of Dimensions TM Inverters 4467 White Bear Parkway St. Paul, MN 55110 Phone: 651-653-7000 Fax: 651-653-7600 E-mail: inverterinfo@sensata.com Web: www.dimensions.sensata.com 121114C OWNERS
More informationDANGER. See Wiring Diagrams on page 7 for illustrations of both internal and connection wiring diagrams. WARNING
January 009 I4-403C A1800 APHA Meter Installation Instructions General This leaflet contains general installation instructions for 4-wire and 3-wire applications of the A1800 APHA meters. All meters are
More informationInstallation Power Management Unit Battery Cables and Battery Harness
Installation Power Management Unit Battery Cables and Battery Harness Important Safety Messages SAVE THESE INSTRUCTIONS - This manual contains important instructions that should be followed during installation
More informationInstallation and Operation Guide
Bus-Scan CR2 RF Installation and Operation Guide All Content and Information are Copyright 2018 Robotics Technologies, Inc. Features and Information are subject to change without notice. All Rights Reserved.
More informationADI-125/750 ADI-125/1500 ADI-125/2500
Manufacturer of Dimensions TM Inverters 4467 White Bear Parkway St. Paul, MN 55110 Phone: 651-653-7000 Fax: 651-653-7600 E-mail: inverterinfo@sensata.com Web: www.dimensions.sensata.com 121094B OWNERS
More informationSYSTEM MANUAL. Automated Motorized Hydraulic Traffic Controller. Revision CS72-HTC
CS72-HTC SYSTEM MANUAL Automated Motorized Hydraulic Traffic Controller Revision 2002.01 Spike Systems 3623 S. Seventh Street Phoenix, Arizona 85040 Phone: (602) 243-0291 Fax: (602) 243-0294 Hydraulic
More informationXPC-EBP64 External Battery Pack User & Installation Manual Xtreme Power Conversion Corporation. All rights reserved.
XPC-EBP64 User & Installation Manual www.xpcc.com 2015. All rights reserved. (Rev 9/28/15) Table of Contents Introduction...5 Product Description...5 Extended Battery Pack Configurations...6 Safety Information...7
More informationDISCONTINUED VERSION Parts listed in this catalog may no longer be available. ILLUSTRATED PARTS CATALOG
BUNN WL WARMER DISCONTINUED VERSION Parts listed in this catalog may no longer be available. FRONT REAR ILLUSTRATED PARTS CATALOG Designs, materials, weights, specifications, and dimensions for equipment
More informationLEXION SINGLE FUNCTION HYDRAULIC VALVE KIT
LEXION SINGLE FUNCTION HYDRAULIC VALVE KIT Conversion Manual 09062010b HEADSIGHT.COM 574.546.5022 About Headsight Headsight Contact Info Headsight, Inc. 4845 3B Road Bremen, IN 46506 Phone: 574-546-5022
More informationAir-Boss VP Intake Plenum
Installation Manual P/N 98502-ABIP 98.5-02 DODGE CUMMINS Air-Boss VP Intake Plenum Installation Instructions P/N 98502-ABIP GDP Air-Boss VP Plenum Installation PLEASE READ ALL INSTRUCTIONS BEFORE BEGINNING
More informationSubmersible Pump Model FA10.78Z with 4 Pole, 1740 RPM Motor and Two Vane Impeller
Submersible Pump Model FA10.78Z with 4 Pole, 1740 RPM Motor and Two Vane Impeller Project Name: Project Manager: Chris Harnevious, Order Management Prepared By: Ray Herndon, Order Management FA 10.78Z,
More informationInstallation and Operation Guide
Bus-Scan 500 RF Installation and Operation Guide All Content and Information are Copyright 2018-2019 Robotics Technologies, Inc. Features and Information are subject to change without notice. All Rights
More informationRV-10 Center Arm Rest Console
RV-10 Center Arm Rest Console Important Notice: This manual contains important information that may affect the safety of your aircraft. Read the Warranty / Agreement below. There is information in the
More informationDODGE CUMMINS 24V ISB OEM BYPASS LIFT PUMP KIT Installation Instructions Part #
2/15/2006 2000-2002 Dodge Cummins OEM Bypass Lift Pump Kit # 1050229-1 - 2000-02 DODGE CUMMINS 24V ISB OEM BYPASS LIFT PUMP KIT Installation Instructions Part # 1050229 PLEASE READ ALL INSTRUCTIONS CAREFULLY
More informationCBC-160-1N and CBC-160-2N Clutch/Brake Controls
P-239-36 819-04 CBC-160-1N and Clutch/Brake Controls Installation Instructions An Altra Industrial Motion Company Contents Introduction...2 Specifications........................... 2 Installation...3
More informationWiFi Tank Level Monitor Installation Instructions
WiFi Tank Level Monitor Installation Instructions COMPATIBILITY To install the Tank Utility remote level monitor, you will need the following: A WiFi connection at your tank site An Apple or Android smartphone
More informationDODGE CUMMINS Arctic-Heat Grid Relocation Kit
Installation Manual P/N 07509-350-GRK 2007.5-09 DODGE CUMMINS Arctic-Heat Grid Relocation Kit Installation Instructions P/N 07509-350-GRK GDP Arctic-Heat Grid Heater Installation PLEASE READ ALL INSTRUCTIONS
More informationDIGITAL VOLTAGE INDICATORS
DIGITAL VOLTAGE INDICATORS a nd ACCESSORIES Operating & Instruction Manual DVI-100 DVI-500 1475 Lakeside Drive Waukegan, Illinois 60085 U.S.A. 847.473.4980 f a x 8 4 7. 4 7 3. 4 9 8 1 w e b s i t e : w
More information(L 70 ) 3000K / 4000K / 5000K 12 50,000 50, K / 4000K / 5000K 15 50, K / 4000K / 5000K 18 50,000
Applicable Cooler Door Models: WATTS (NOMINAL) MODEL LIFE (L 70 ) DIMENSIONS (L x W x H) Nom CCT 9 36RDLxx 3ft x 1in x ¾ H 12 48RDLxx 4ft x 1in x ¾ H 15 60RDLxx 5ft x 1in x ¾ H 18 72RDLxx 6ft x 1in x ¾
More informationTROUBLESHOOTING For assistance with your machine, visit our website at www.deltamachinery.com for a list of service centers or call the DELTA Machinery help line at 1-800-223-7278 (In Canada call 1-800-463-3582).
More informationHP30 Slab Saw Owner s Manual and Operating Instructions
HP30 Slab Saw Owner s Manual and Operating Instructions MADE IN USA Revision 07 09.0 Manual Part No. 67 Caution: Read all safety and operating instructions before using this equipment. This manual MUST
More informationIllustrations on the manual are for installation purposes only. It may not be identical to the fixture purchased.
General Safety Information To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/abrasions, and other hazards read all warnings and instructions
More informationBP1204 INSTALLATION/OWNER'S MANUAL
BP1204 INSTALLATION/OWNER'S MANUAL BP1204 PREPARATION Getting Started Thank you for purchasing the Dual Electronics BP1204 Bandpass Subwoofer System. Although Dual has attempted to ensure the information
More informationMANUAL Model: PT 12/24-60 Solar Converters Inc. - Rev. F
1.0 Specification MANUAL Model: PT 12/24-60 Solar Converters Inc. - Rev. F Note: This unit is a Multi - Voltage unit with adjustable input panel and output battery adjustment. Please review the section
More informationJOHN DEERE 9970 COTTON PICKERS
PARTS CATALOG FOR Mud Hog System II Rear Wheel Drive FOR JOHN DEERE 9970 COTTON PICKERS Mud Hog Model Numbers Tread Center OEM Aftermarket JD40005 JD47655 82, 90, 94, 106 TUTHILL Drive Systems 9098 West
More informationSurface or Pedestal Mount Viking Products While Maintaining Weather and Vandal Resistance
Designed, Manufactured and Supported in the USA VIKING PRODUCT MANUAL SECURITY & COMMUNICATION SOLUTIONS VE-Series Surface Mount Boxes and Pedestals January 29, 2018 Surface or Pedestal Mount Viking Products
More informationLX-80 COMMERCIAL POOL & SPA CONTROL INSTALLATION INSTRUCTIONS
LX-80 COMMERCIAL POOL & SPA CONTROL INSTALLATION INSTRUCTIONS IMPORTANT SAFETY PRECAUTIONS: All wiring must be performed by a qualified electrician. Basic safety precautions and local codes should be observed
More informationFlo-Way. Measure Granular or Powdered Material. Stand Alone or Connect to Other Devices for Blending. Used by Successful Producers World-Wide
Flo-Way R Solids Impact Flow Meter Measure Granular or Powdered Material Stand Alone or Connect to Other Devices for Blending Used by Successful Producers World-Wide Visit our website: www.beltwayscales.com
More informationThrough-Shaft Clutch-Brake LSCB-32HT, LSCB-32HT, LSCB-44, LSCB-44HT, LSCB-54HT FORM NO. L D-0606 MEX (55) QRO (442)
Through-Shaft Clutch-Brake LSCB-HT, LSCB-HT, LSCB-, LSCB-HT, LSCB-5HT In accordance with Nexen s established policy of constant product improvement, the specifications contained in this manual are subject
More informationADJUSTABLE COMFORT ASSEMBLY INSTRUCTIONS
ASSEMBLY INSTRUCTIONS ASSEMBLY INSTRUCTIONS For customer service call 1-877-707-7533 or email azcustomerservice@classicbrands.org STEP 1: Carefully open the carton and remove all boxes then lay out the
More informationInstallation Instructions. Fog Lights. The lamps get very hot when they have been in use. Do not touch them as they may cause burns.
2100X Installation Instructions Thank you very much for purchasing PIAA product. Please read this entire manual before installation and use of this product. Fog Lights For Installers Please give this Installation
More informationDual Phase Extraction Inlet. Patent No Installation Manual. P/N Rev
Patent No. 6520259 Installation Manual P/N 95232 Rev 6-16-11 Table of Contents ing Extraction Inlets track changing water levels to maintain optimum performance 1.Component Identification Page 1 2. How
More informationManufacturing Facility is ISO9001:2000. Welded Steel Pipe Conform to ASTM A53. Threads Conform to ASME B1.20.1
STEEL NIPPLES S40 & S80 Steel Nipple Product Specifications Manufacturing Facility is ISO9001:2000 Welded Steel Pipe Conform to ASTM A53 Threads Conform to ASME B1.20.1 800-678-2544 800-678-0857 www.msi-products.com
More informationCORN HEADER MANUAL: CNH PRE-2012
CORN HEADER MANUAL: CNH PRE-2012 09020201c HEADSIGHT.COM 574.546.5022 About Headsight Headsight Contact Info Headsight, Inc. 4845 3B Road Bremen, IN 46506 Phone: 574-546-5022 Fax: 574-546-5760 Email:
More informationINSTALLATION/OWNER'S MANUAL DP " Woofer in Enclosure
INSTALLATION/OWNER'S MANUAL DP1000 10" Woofer in Enclosure Installation Thank you for purchasing the DP1000 10" Woofer with enclosure. Although Dual has attempted to make sure all of the information contained
More information20250 Module Installation Guide
20250 Module Installation Guide 2013.5-2017 RAM 6.7L Cummins Up to 90HP Gain 1-3 MPG Fuel Savings AgDieselSolutions.com Adjustable switch connector Power +12 volts (Red wire) & Ground (Black wire) Injector
More informationSINGLE STICK DIGITAL VOLTMETER
SINGLE STICK DIGITAL VOLTMETER a n d A C C E S S O R I E S Operating & Instruction Manual 1475 Lakeside Drive Waukegan, Illinois 60085 U.S.A. 847.473.4980 f a x 8 4 7. 4 7 3. 4 9 8 1 w e b s i t e : w
More informationCompressor Clutch Replacement Procedure
P-1411 819-0361 Compressor Clutch Replacement Procedure Installation Instructions World Clutch with Unidamp Armature for Ford FX-15 and FS-10 Compressors and all Denso Models with 30mm bearing fit. Keep
More informationGuardian NV Flywheel Coupling
Guardian NV Flywheel Coupling P-8605-GC GUA-MRK-DOC-014 Service & Installation Instructions TABLE OF CONTENTS NOTICES AND WARNINGS PAGE 2 SECTION 1 COUPLING OVERVIEW PAGE 3 SECTION 2 TOOLS/MATERIALS REQUIRED
More informationSLAB SAW SERIES PARTS LIST
SLAB SAW SERIES PARTS LIST MODELS: HP Part# 020 HP20 Part# 02020 HP2 Part# 0202 MADE IN USA MADE IN USA Revision 09.20 Manual Part No. 6269 Caution: Read all safety and operating instructions before using
More informationGuardian FBA Flywheel Coupling
Guardian FBA Flywheel Coupling P-8602-GC GUA-MRK-DOC-010 Service & Installation Instructions TABLE OF CONTENTS NOTICES AND WARNINGS PAGE 2 SECTION 1 COUPLING OVERVIEW PAGE 3 SECTION 2 TOOLS/MATERIALS REQUIRED
More informationManual Transfer Switch
Manual Transfer Switch Instruction Manual 30 1200 Amp 2, 3 & 4 Pole Page 1 WARNING Before Installation READ THIS MANUAL carefully to learn how to properly install, operate and maintain this unit. Personal
More informationWeb Volume Control Model WV220
WEB CONTROL PRODUCTS User Manual Web Volume Control Model WV220 1 In accordance with Nexen s established policy of constant product improvement, the specifications contained in this manual are subject
More informationMaxLite LED UTILITY WRAP FIXTURES
General Safety Information To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/abrasions, and other hazards read all warnings and instructions
More informationINSTALLATION AND OPERATION MANUAL
INSTALLATION AND OPERATION MANUAL Models S120U & S240U Read all instructions before assembling or using the SunHeater system. Retain this manual for future use. TABLE OF CONTENTS Important Safety Information...2
More informationDODGE CUMMINS GDP Twin CP-3 Big Line Kit
Installation Manual P/N 0306-TCP3 2003-07 DODGE CUMMINS GDP Twin CP-3 Big Line Kit Installation Instructions P/N 0306-TCP3 GDP Twin CP-3 Big Line Kit Installation PLEASE READ ALL INSTRUCTIONS BEFORE BEGINNING
More informationBEAMER Tilt Beam Sensor
User s Manual BEAMER Tilt Beam Sensor Serial No. 140 Chestnut Street San Francisco, CA 94111 Phone: 415 364 3200 Fax: 415 861 1448 www.geomechanics.com CAUTION: Never measure the sensor inside your Beamer
More information6-TON DOUBLE LOCKING JACK STANDS OWNER S MANUAL
6-TON DOUBLE LOCKING JACK STANDS OWNER S MANUAL WARNING: Read carefully and understand all ASSEMBLY AND OPERATION INSTRUCTIONS before operating. Failure to follow the safety rules and other basic safety
More information