Part Numbers. 9007A and 9007C Basic snap switch without enclosures with or without operators 21-6

Size: px
Start display at page:

Download "Part Numbers. 9007A and 9007C Basic snap switch without enclosures with or without operators 21-6"

Transcription

1 Table of Contents Section Limit Switches Encapsulated Miniature Industrial Snap Switches 9007MS, A, p. - Modular, Miniature and Compact Part Numbers 9007A and 9007C Basic snap switch without enclosures with or without operators MS and 9007ML Encapsulated switches with NEMA P rating and 0 A contacts -8 XCMD Osisense miniature metal modular - XCMN Osisense compact non-modular - XCKD Osisense compact metal modular - XCKP Osisense compact plastic modular - XCMD, - XCKD, - XCKT Osisense compact plastic with side-cable entries and modular head - XCDR Osisense compact metal with manual reset - XCPR Osisense compact plastic with manual reset - XCKP, - XCKT, - ZCE, ZCY Osisense component heads and lever arms - Compact General Duty ZCD, ZCMC, ZCMD, ZCP, ZCPE Osisense component bodies, cable plug assemblies, and conduit entries -7 XCKN, XCNR Osisense compact, plastic, non-modular -8 XCKS Standard body, plastic, double insulated -9 XCKL, 9007C, p. - XCKL Compact general duty, metal, with direct opening contacts Heavy Duty Industrial XCKJ Precision switches with direct acting contacts to meet most international standards C Heavy duty, oiltight, watertight switches, with compact types available T and 9007FT Severe duty, oiltight mill and foundry switches with 0 A contacts C, p. - XCKJ, -0 L00/L00 Severe duty, oiltight mill and foundry switches with up to circuits -9 Severe Duty 9007T, -7 L00, -9 0 Schneider Electric -

2 Limit Switches Product Panorama Refer to Catalog 900CT007 Design Miniature Compact Catalog number 9007 A/O 9007 MS/ML XCMN XCMD XCKP XCKD XCKL Page Enclosure Open, plastic Metal body, metal head Features A variety of operators are available. Bottom or side cable entry. Full range of operating heads. See page -8. v Plastic, double insulated Mounting by the body or by the head Metal Plastic, double insulated Metal Metal conduit entry Modularity Selected operators Operator Head, body, lever, and connector Head, body, and lever Conforming to standards CENELEC: EN 5007 Body dimensions (w x h x d), mm (in.) 9.0 x.5 x.0 (. x.5 x 0.8) 0. x. x.8 (8 x.75 x 0.) Head Linear Linear or rotary Contact blocks 0 x 50 x (.8 x.97 x 0.) snap action contacts N.C. + N.O. snap action contacts N.C. + N.O. x 5 x 0 (. x.5 x.8) Linear movement, plunger Rotary movement, lever Rotary movement, multi-directional a Same heads for ranges XCMD, XCKD, XCKP and XCKT N.C. + N.O.; N.C. + N.C. N.C. + N.O.; N.C. + N.C. snap action contacts N.C. + N.C. + N.O. snap action contacts N.C. + N.C. + N.O. snap action contacts snap action contacts slow break contacts break before make slow break contacts break before make slow break contacts make before break slow break contacts make before break slow break contacts simultaneous slow break contacts simultaneous slow break contacts break before make slow break contacts break before make snap action contacts snap action contacts Insulation voltage (Ui) / thermal current (Ithe) N.C. + N.C. + N.O. + N.O. N.C. + N.C. + N.O. + N.O. N.C. + N.O.; N.C. + N.C. N.C. + N.O.; N.C. + N.C. N.C. + N.C. + N.O.; N.C. + N.C. + N.O.; N.C. + N.O.; N.C. + N.C. N.C. + N.O.; N.C. + N.C. N.C. + N.C. + N.O.; N.C. + N.C. + N.O.; 5 x 7 x 0 (.05 x.8 x.8) Linear movement, plunger Rotary movement, lever Rotary movement, multi-directional a N.C. + N.O. N.C. + N.O. N.C. + N.C. + N.O.; N.C. + N.C. + N.O.; N.C. + N.O. N.C. + N.O. N.C. + N.O. N.C. + N.O. N.C. + N.O. N.C. + N.O. N.C. + N.O. N.C. + N.O. N.O. + N.C. N.O. + N.C. N.O. + N.C. N.O. + N.C. N.O. + N.C. N.O. + N.C. N.C. + N.C. N.C. + N.C. N.C. + N.C. N.O. + N.O. N.O. + N.O. N.O. + N.O. N.C. + N.C. + N.O. N.C. + N.C. + N.O. N.C. + N.O., N.O. + N.O. N.C. + N.C., N.O. + N.O. Enclosure rating IP = IEC enclosure rating None IK = EN shock test standard Electrical connection a See page - Screw terminal or Faston connector N.C. + N.C. + N.O.; N.C. + N.C. + N.O.; N.C. + N.C. + N.O.; N.C. + N.C. + N.O.; N.C. + N.O. 00 Vac/Vdc 0 A (standard) NEMA Types,,,, P,, IP7 Pre-wired cable or M connector Flexible operators do not guarantee direct (positive) opening operation. Screw terminal contacts: 00 V/ A NEMA Types,, IP 5, IK 0 Pre-wired cable Pre-cabled contacts: 00 V/ A contacts: 00 V/ A contacts: 00 V/ A NEMA Types,, X,, IP, IP 7, IP 8, IK 0 Pre-cabled. Connector: Integral or remote M or remote 7/8" UN Screw terminal: contacts: 500 V/0 A contacts: 00 V/ A Connector: Integral M, -pin: 50 V/ A NEMA Types,,,, P,, IP, IP 7, IK 0 Screw terminal: contacts: 500 V/0 A contacts: 00 V/ A Connector: Integral M, 5-pin: 0 V/ A NEMA Types,,,,, IP, IP 7, IK 0 Screw terminal: M, M0, Pg, PG, /" NPT, or PF / Connector: Integral M N.C. + N.C. + N.O.; N.C. + N.C. + N.O.; Screw terminal: contacts: 500 V/0 A contacts: 00 V/ A NEMA Types,,,, P,, IP, IK 0 Screw terminal: M0 or /" NPT - 0 Schneider Electric

3 Limit Switches Product Panorama Refer to Catalog 900CT007 Design Standard Duty Industrial Severe Duty Mill and Foundry Catalog number 9007C XCKJ XCKS 9007T/FT L00/L00 Page Enclosure Metal, diecast, zinc alloy Metal Plastic, double insulated Metal Metal Features Plug-in body Fixed or plug-in body, -0 C (-0 F) or + C (+8 F) versions Modularity Head, body, and lever Lever Conforming to standards / Product certifications Body dimensions (w x h x d), mm (in.) Head UL 508, C---95, NEMA 50, IEC 097, EN 097-, EN Standard: 9 x 0 x 5 ( x.0 x.77) Compact: 9 x 80 x 5 ( x. x.77) Linear movement, plunger Rotary movement, lever Multi-directional movement (wobble stick, cat whisker) c CENELEC: EN x 77 x (7 x.0 x.7).5 x 8 x (.7 x. x.) Linear movement, plunger Rotary movement, lever Rotary movement, multi-directional c CENELEC: EN x 7.5 x (7 x.85 x.) Linear movement, plunger Rotary movement, lever Rotary movement, multi-directional c Extra heavy duty contact ratings NEMA A00 UL508 UL Listed, CSA Certified 58.7 x. x.5 (. x.5 x.5) Rotary movement, lever Extra heavy duty contact ratings High temperature option, unique in the marketplace NEMA A00 UL508 UL Listed, CSA Certified 58.7 x x 5. (. x.95 x.0) Rotary movement, lever Contact blocks Various options available for L00, - and -pole devices. snap action contacts N.C. + N.O.; N.C. + N.C. N.C. + N.O.; N.C. + N.C. snap action contacts N.C. + N.O.; N.C. + N.C. N.C. + N.O.; N.C. + N.C. snap action contacts snap action contacts 0 Schneider Electric N.C. + N.C. + N.O.; N.C. + N.C. + N.O.; N.C. + N.C. + N.O.; N.C. + N.C. + N.O.; snap action contacts snap action contacts slow break contacts break before make slow break contacts break before make slow break contacts make before break slow break contacts make before break slow break contacts simultaneous slow break contacts simultaneous slow break contacts break before make slow break contacts break before make slow break contact Form Y a N.C. + N.O. N.C. + N.O. N.O. + N.C. N.O. + N.C. N.C. + N.C. N.O. + N.O. N.O. + N.O. N.C. + N.C. + N.O. ; N.C. + N.C. + N.O. ; N.C. + N.C. + N.O.; N.C. + N.C. + N.O.; N.C snap action contacts N.O. + N.C. C/O C/O snap action contacts Insulation voltage (Ui) and thermal current (Ithe) Enclosure rating IP = IEC enclosure rating IK = EN shock test standard Electrical connection a b c N.O. + N.C. ; N.O. + N.C., neutral position; N.O. + N.C., two stage Ui = 00 V, except: 9007C, 9007C, 9007C8 (Ui = 50 V) and 9007C8, 9007C8 (Ui = V) Ithe = 0 A, except: 9007C8, 9007C8 (Ithe =.5 A) IP 7 conforming to IEC 059, NEMA Types,,, P,, Cable entry /"- NPT, M0 x ISO cable entry Connector Integral 5-pin mini-connector Single pole only. Refer to page -9 for details. For other contact options, see catalog 900CT007. Flexible operators do not guarantee direct (positive) opening operation. N.C. + N.O.b convertible sequence Screw terminal contacts: 500 V/0 A contacts: 00 V/ A Connector Integral M, 5-pin: 0 V / A Integral 7/8" UN: 50 V / A NEMA Types,,, IP, IK 07 Screw terminal M0 x, PG, or /" PT Connector Integral M or 7/8" UN Screw terminal contacts: 500 V/0 A contacts: 00 V/ A IP 5, IK 0 Screw terminal M0 x or PG 00 V 0 A (AC/DC) NEMA Types,,,, IP5,, 7 Cable entry /" NPT or PG N.C. + N.O.b Some conversions possible 00 V 0 A (AC), 5 A (DC) NEMA Types,, IP5, Cable entry /" NPT or /" NPT Other options available Connector 7/8" UN or Cannon MS0E0-AP or equal; other options available -

4 Application Data Table.: a b c Type Enclosure Ratings NEMA Style IEC Style X P 7 9 IP5 IP IP7 9007C a a a a a a a a a a 9007CR a a a a a a a a a 9007FT a a a a a a a a L00/L00 a a a a a 9007MS/ML c a a a a a a a a a 9007T a a a a a a a a XCKJ a a a a a a XCKL a a a a a a XCKN & XCNR a a a XCKP & XCKT b a a a a XCKS, XCMN XCMD, XCKD a a a a a a Indicates NEMA or IEC Type Rating available for each product. For indoor use onlynot UV protected. Enclosure ratings are NEMA,,,,, P,, and except for option (low force) which is NEMA only. The 9007 MS/ML05 (omni-directional operation) enclosure ratings are NEMA,,, and Table.: 9007C, CR R.B.Denison L 9007T and FT Sealing Type Standard shaft seals on lever types Plunger and wobble stick boots All other seals a Material Fluorocarbon rubber (FKM) Neoprene; Fluorocarbon optional Nitrile (Buna N); Fluorocarbon optional PVC Shaft seal Nitrile (Buna N) Cover gasket Nitrile (Buna N) Base plate gasket Cellulose fiber laminate XCKJ, XCKL, XCKS Nitrile (Buna N) XCMD, XCKD, XCKP, XCKT, XCKN, XCNR Nitrile (Buna N) and silicon All Limit Switch Types Refer to Catalog 900CT007 Table.: Ambient Temperature Ranges The low temperatures listed below are based on the absence of freezing moisture or water. Care should be taken to avoid sub-freezing temperatures where dripping or splashing water is present and to avoid bringing a cold switch into a warm humid atmosphere and then back into sub-freezing temperatures. The water or moisture can freeze around the switch lever arm or plunger and cause jamming. Type Low Temperature High Temperature at Full Rated Load 9007 C Lever Type -0 F (-8.9 C) +85 F (+85 C) Plunger & Wobble Stick Type 0 F (-7.8 C) +85 F (+85 C) 9007 FTd, T -0 F (- C) +85 F (+85 C) HL00/HL00 0 F (-7.8 C) +50 F (+77 C) L00/L00 0 F (-7.8 C) +00 F (+9 C) 9007 MS/ML - F (-0 C) + F (+05 C) XCKJ, XCKL, XCKP, XCKT - F (-5 C) +8 F (+70 C) XCMN, XCKN, XCNR - F (-5 C) +8 F (+70 C) XCKS - F (-5 C) +8 F (+70 C) XCMD - F (-5 C) +8 F (+70 C) d The Type FT will withstand hot falling sand up to +00 F (+9 C); however, ambient temperature for the FT switch is the same as the Type T above (+85 F, +85 C). Do not use in higher temperature ambients. Some switches are available with higher or lower temperature limits, by selecting special versions or special options. Refer to the respective product sections for further information. (Ex.: 9007MS/ML, see page -9.) Table.: Volts Electrical Contact Ratings ACNEMA A00 Max. Current5% Power Factor 0 0./0.55 e 8/9 e 5/.5 e e Type C5 compact unit ratings at Vdcsame ratings as C5, CF5 and CR5 at other voltages. DC Maximum Current Make Break Continuous Volts Make or Break Carrying A VA A VA Amperes A VA Continuous Carrying Amperes Table.5: B C D Contact Function Diagrams A P tripping resetting A=Maximum travel of the operator in mm or degrees. B=Tripping travel of the contact. C=Reset travel. D=B-C=Differential travel. P=Point from which positive opening is assured Make-before-break (overlapping) SPDT The normally open contact closes before the normally closed contact opens. Break-before-make (offset) SPDT The normally closed contact opens before the normally open contact closes. Simultaneous make and breakspdt The normally closed contact opens at the same time as the normally open contact closes. Table.: Wiring Diagrams Form A Form B Form C Form AA Form BB Form CC SPST-NO SPST-NC SPDT DPST-NO DPST-NC DPDT Form X SPST- NO-DB Form Y Form Zb Form Z Form XX Form YY Form ZZ SPST- NC-DB SPDT-DB Isolated Contacts SPDT-DB DPST- NO-DB DPST- NC-DB DPDT-DB - 0 Schneider Electric

5 Current Ratings All Limit Switch Types Refer to Catalog 900CT007 Contact ConfigurationsDirect opening contacts meet IEC requirements. For contacts used in safety applications (end of travel, emergency stop device, etc.) the assurance of direct opening is required (see IEC 0, EN 00 or NF C 79-0) after each test. The opening of the contact must be verified by testing with an impulse voltage (500 V). Table.7: Switch Type L00/L00 XCKD Contacts XCKD Contacts XCKJ Plug-in XCKJ Non-plug-in XCKL Maximum Current Ratings for Control Circuit ContactsAll Types Contacts SPDT with or Contacts Form Z SPDT Form Zb Direct Opening Contacts Meet IEC Requirements No Yes Pole Form Zb Yes SPDT Form Z SPDT Form ZZ SPDT Form Zb No No Yes SPDT Form ZZ No SPDT Form Zb Yes XCKN Pole Yes XCKP Contacts XCKP Contacts XCKT Contacts XCKT Contacts XCMD - Contacts XCMN Contacts SPDT Form Zb Yes Pole Form Zb Yes SPDT Form Zb Yes Pole Form Zb Yes, or Pole Form Zb SPDT Form Zb Yes Yes XCNR Pole Yes 9007AO, AC 9007AO, AO, AB, AP 9007CO, CO, CB, CC, CP 9007C 9007MS 9007ML 9007T and FT SPST, Form X or Y (rated and 00 Vac) SPDT, Form Z SPST, Form X or Y (rated and 00 Vac) SPDT, Form Z DPST Form AA or BB DPDT Form ZZ SPST Form Y Slow break SPDT Form Z DPDT Form ZZ SPDT Form C SPDT Form Z SPDT Quick Make and Break Form Z All Slow Make and Break Form Z No No No Yes No No No No No No V AC50 or 0 Hz DC AC/DC Inductive 5% Power Factor Resistive 75% Power Factor Inductive and Resistive Continuous Make Break V Carrying Make and Make and Break Amperes Amperes A VA A VA Break Amperes Single Pole Double Pole /5 0/.5 5/ /.5 0 0/ /.5 0/.5 5/.0 0/.5 5/.0 5/.0 5/.0 0/ / /.5 0/.0 0 (AC) / 5 8 Vdc) 0 (AC) / 5 8 Vdc) 0 0 Electrical Symbols For Contacts Form Za: the contacts are the same polarity. Form Zb: the contacts are electrically separate. Symbols for Direct Opening Simplified Version Complete symbol Note: Alternate Current RatingsSeveral product lines offer special versions or options with alternate contact configurations or contact materials, which may result in current ratings that differ from those listed above. Refer to the respective product sections for further information. 0 Schneider Electric -5

6 Industrial Snap Switches Type AO 9007AO, 9007CO Class 9007 / Refer to Catalog 900CT007 Industrial Snap Switches Without Enclosures Industrial snap switches have been incorporated in many Square D products such as timers, specialty push buttons, foot switches, operating mechanisms, door interlocks, motor control centers, limit switches, and many other control products. Recommended Actuator: An adjustable actuator is recommended. If nonadjustable actuator is used, a resilient type or a mechanical stop should be used to prevent bottoming of button mechanism. Adjustable Actuator Overtravel: Minimum recommended overtravel in both trip and reset directions is 0.0 in. Adjustable Actuator Total Travel: Maximum differential limit plus 0.00 in. (Example: 0.07 in. for Type AO.) Nonadjustable Actuator Total Travel: Fully retractedat least 0.9 in. for Type AO and 0.0 in. for Types AO and CO from mounting surface. Fully engagedat least 0.0 in. but not closer than 0.05 in. from mounting surface. Contact Configurations: Single-pole snap switches that contain two double-break contact elements ( N.O. and N.C.) must be used on circuits of the same polarity. Double-pole snap switches contain two electrically separated sets of contact elements allowing use on circuits of opposite polarity. Each set contains two double-break contact elements ( N.O. and N.C.) that must be used on circuits of the same polarity. Type AB Type AP with 58CG mushroom button Table.8: Quick Make and Break00 Volts Max. AC and DC Operator Style Contact Arrangement Type Operator Style Contact Arrangement Type N.O. N.C. AO N.O. N.C. AC N.C. AOA Cabinet Door Style N.O. N.C. CC N.O. AOB N.O. AO N.O. N.C. AO (Plug-in) N.C. AP Basic Snap Switch N.C. AOA Plunger Style N.O. AOB Panel Mounting N.O. N.C. CP N.O. N.C. CO Operator Only AP0 g N.O. CO (Plug-in) N.O. N.C. AP Two Stage N.O. N.C. Rigid Roller Lever Style Rigid Roller Lever Style One Way Roller N.O. N.C. 7/" width roller N.O. N.C. /" width roller N.O. N.C. 7/" width roller N.O. N.C. /" width roller N.O. N.C. N.O. N.C. CO7 Roller Plunger Style N.O. CP Panel Mounting N.C. AB (RH) Non-Oiltight CP f AB (LH) AP0 g Operator Only AB (without side mtg. bracket) AP0 fg AB (RH) N.O. AP AB (LH) N.C. AP5 f CB (RH) Roller Plunger Style N.O. CP Panel Mounting CB (without side mtg. bracket) N.C. CP5 f Oiltight CB (RH) AP0 g CB (LH) Operator Only AP05 fg AB5 (RH) N.O. N.C. AP AB (LH) CB5 (RH) CB (LH) Mushroom Button Style Panel Mounting f g N.O. N.C. CP Operator Only AP0 g Roller turned 90 from standard (perpendicular to mounting holes). For use with Type AO and CO basic switches. Table.9: Switch Type AO, AC AW, AO, and AO, AB, AP AW, CO, and CO, CB, CC, CP h Maximum Current Ratings For Control ContactsAll Types Contacts h SPDT Form Z SPST Form X or Y SPDT Form Z SPST Form X or Y DPDT Form ZZ DPST Form AA or BB Voltage AC50 or 0 Hz Inductive 5% Power Factor Resistive 75% Power Factor Make Break Make and Break A VA A VA Amperes Do not meet IEC requirements for direct opening contacts Voltage DC Inductive and Resistive Make and Break Amperes Single Pole Double Pole AC or DC Continuous Carrying Amperes Acceptable Wire Size AWG Recommended Terminal Clamp Torque lb-in (0.7.0 N m) File E59 CCN NKCR File LR590 Class -0-0 Schneider Electric

7 Industrial Snap Switches 9007AO, CO, AP, CP Dimensions Refer to Catalog 900CT007 Approximate Dimensions and Operating Data, 9007AO, CO, AP, and CP 9007AO, Single-Pole Snap Switch 9007CO, Two-Pole Snap Switch 0.5 R R Mounting Surface Holes for # Mounting Screws B A -# Binder head Terminal Screws 0.5 Dia..5 Operating Button Max..0. A B Must Be Same Polarity -D Mounting Surface Holes for # Mounting Screws 0.5 Dia. Operating Button Max B A A B Pole Pole Dual Dimensions inches mm Pre-travel Differential Total travel Operating force Shipping weight Operating Data, in. (mm) Operating Data, in. (mm) AO, A, B AO, A, B CO C (..8) (0. 0.) ) 7 oz ( N) 0.5 lb (0. kg) (..8) (0.9.) (..) 0 oz ( N) 0.5 lb (0. kg) a Separation between first and second stage trip points is (0.5 0.). Pre-travel st stage Pre-travel nd stage Differential Total travel Operating force Shipping weight (..8) (0..) (..) 7 oz ( N) 0.5 lb (0. kg) (0.9 ) (.) a ( ) 7 oz ( N) 0.5 lb (0. kg) 9007AP0,, and CP 9007AP0, 0, 0, 05,,,, 5, and CP,,, AP0 9007AP Type Dimension A Type Dimension A AP 0.70 (7.8) AP,,, (7.8) CP 0.80 (0.) CP,,, (0.) Operating Data, in. (mm) Operating Data, in. (mm) Pretravel Differential Overtravel Total travel Operating force Shipping weight AP *- Mtg. Screw 0.7" x thread A.0 AP CP AP, AP, 5 CP, CP, (.8.) (0.9.) (..) (5.8.8) 0 oz ( N) 0.5 lb (0. kg) Plunger to mount in /" Dia. Hole in panels up to 0.8" (9.mm) thick (.8.) (0.9.) (..) (5.8.8) 7 oz ( N) 0.5 lb (0. kg) Pretravel Differential Total travel Operating force *- Mtg. Screw Plunger to mount in /" Dia. Hole in panels up to 0.8" (9.mm) thick AP " x thread A (.8) (0.9.) (5. 8.) 0 oz (0. N) (.8) (0.9.) (5. 8.) 8 oz (0. N) (.8) (0.9.) (5. 8.) oz (0.8 N) (.8) (0.9.) (5. 8.) 8 oz (0. N) 0 Schneider Electric -7

8 Encapsulated Miniature 9007MS The heavy-duty, miniature MS limit switch is completely encapsulated and intended for difficult applications such as machine tools, earth moving equipment, and general transportation. 9007MS0S008 The switch has 0 mm mtg hole centers. Table.0: Specifications Temperature range (The minimum temperatures - F to + F (-0 C to +05 C) listed are based on the For -0 F / -0 C minimum temperature, see absence of freezing moisture or Forms and 80 in Table. on page -9. water.) Enclosure rating NEMA,,,, P,,, IP7 Vibration resistance 0 G (75 0 Hz) Shock resistance 5 G Contact Characteristics Rated thermal current 0 A (standard) Rated insulation voltage 00 Vac and Vdc (standard) Gold contact switching ratings 0.A, Vdc; 0. VA Cable #8 AWG SJTO Table.: Selection (append prefix 9007 to the catalog number) Description / Functional Diagramb MS ML Top plunger Parallel roller plunger Cross roller plunger Rotary lever, CW and CCW Not included (see Table. on page -9) Omnidirectionalwire whisker (NEMA,,, only).070" max..080" max. 0.00".9" 0.0".9" max. min. max. min..070" max..080" max. 0.00".9" 0.0".9" max. min. max. min..070" max..080" max. 0.00".9" 0.0".9" max. min. max. min MS/ML Miniature Class 9007 / Refer to Catalog 900CT00 Operating Force/Torque Electrical Ratings/SPDT Form C (MS Type) MS CircuitForm C Silver Contacts Gold Contacts N.O. N.C. Vac Make Break 0 A A A A Vac 0.0 Amperes Continuous 0 ma 8 Vdc DC Contact Rating: 5 A (Res), 8 Vdc Electrical Ratings/SPDT-DB Form Z ML CircuitForm Z (ML Type) Silver Contacts N.O. N.C. Vac Make Break 0 A A 0 0 A A 0.0 Amperes, Continuous DC Contact Rating: 5 A (Res), 8 Vdc Contact Form Contact Type Catalog Number a 80 oz SPDT Form C Silver MS0S oz SPDT Form C Gold MS0G oz SPDT Form Z Silver ML0S oz SPDT Form C Silver MS0S oz SPDT Form C Gold MS0G oz SPDT Form Z Silver ML0S oz SPDT Form C Silver MS0S oz SPDT Form C Gold MS0G oz SPDT Form Z Silver ML0S000 8 oz-in SPDT Form C Silver MS0S000 8 oz-in SPDT Form C Gold MS0G000 8 oz-in SPDT Form Z Silver ML0S000 5 oz-in SPDT Form C Silver MS05S000 oz-in SPDT Form C Gold MS05G000 Bushing mountedtop plunger Bushing mountedparallel roller plunger Bushing mountedcross roller plunger Adjustable top plunger.070" max..080" max. 0.00".9" 0.0".9" max. min. max. min..070" max..080" max. 0.00".9" 0.0".9" max. min. max. min..070" max..080" max. 0.00".9" 0.0".9" max. min. max. min..070" max..080" max. 0.00".9" 0.0".9" max. min. max. min. 80 oz SPDT Form C Silver MS0S oz SPDT Form C Gold MS0G oz SPDT Form Z Silver ML0S oz SPDT Form C Silver MS07S oz SPDT Form C Gold MS07G oz SPDT Form Z Silver ML07S oz SPDT Form C Silver MS08S oz SPDT Form C Gold MS08G oz SPDT Form Z Silver ML08S oz SPDT Form C Silver MS09S oz SPDT Form C Gold MS09G oz SPDT Form Z Silver ML09S000 a For available options and part number explanations, see page -9. Add options to the end of the catalog number. Up to three options may be added, if applicable. b If the application includes oil, booted switches are recommended. See page -9. File CCN E59 NKCR File Class LR Schneider Electric

9 Encapsulated Miniature, Lever Arms and Options Table.: SelectionBooted Devices (append prefix 9007 to the catalog number) Description / Functional Diagram Booted top plunger Booted parallel roller plunger Booted cross roller plunger a b MS ML.070" max..080" max. 0.00".9" 0.0".9" max. min. max. min..070" max..080" max. 0.00".9" 0.0".9" max. min. max. min..070" max..080" max. 0.00".9" 0.0".9" max. min. max. min. Operating Force/Torque 9007MS/ML Miniature Class 9007 / Refer to Catalog 900CT007 Contact Form Contact Type Cataloga Number b 80 oz SPDT Form C Silver MS0S oz SPDT Form C Gold MS0G oz SPDT Form Z Silver ML0S oz SPDT Form C Silver MSS oz SPDT Form C Gold MSG oz SPDT Form Z Silver MLS oz SPDT Form C Silver MSS oz SPDT Form C Gold MSG oz SPDT Form Z Silver MLS000 See available options below. Add to the end of the catalog number. Up to three options may be added, if applicable. This catalog number is for devices with a standard cable and no options.see Table. for other cable length selections and general options. Table.: Cable Length and General Options Designators: 9007MS0Sxxyy Replace xx and yy in the catalog number above with the designators in the tables below. Some combinations of cable lengths and options are unavailable; consult Schneider Electric. Shown with side entrance cable, option 0 Cable Length (xx)a Designator General Options (yy) a Designator No cable c 00 # AWG SJTO cable (MS only) 0 ftstandard 0 Side entrance #8 AWG SJTO cable 0 ft 0 Gray #8 AWG SJTO cable 0 9 ft 0 #8 AWG individual conductors ft 0 Male pin mini-connector with ft cable (MS only) 8 ft 05 Low force (8 oz), low temp (-0 F / -0 C ), NEMA only ft High Pre-traveladds c Use with options 5, 55, and 8. Male pin micro-connector in housing (DC type) (MS only) 5 Male 5 pin micro-connector (DC type) (ML only) 55 Low temperature (-0 F / -0 C), 9007MS0 (NEMA only) 80 Tapped holes in top of plunger housing (MS and ML) 8 Male pin micro-connector in housing (AC type) (MS only) 8 Black #8 AWG SJTO cable (ML only) 8 Male -pin micro-connector in housing (AC type) (no cable 8 Table.: Style 7 Levers0.75 in. (9 mm) diameter, nylon or steel roller (9007 prefix is not required on lever catalog numbers) Lever Length Catalog Number / in. ( mm) Wide Catalog Number / in. ( mm) Wide Catalog Number / in. (9 mm) Wide Catalog Number in. (5 mm) Wide inch (mm) Nylon Steel Nylon Steel Nylon Nylon (.) 7AN 7A 7BN 7B 7FN 7JN.75 (.9) 7AN 7BN 7FN 7JN (8.0) 7AN 7A 7BN 7FN 7JN.75 (.5) 7A7N 7B7N 7F7N 7J7N.00 (50.8) 7AN 7BN 7FN 7JN Note: Lever tightening torque for mounting the lever on the shaft: minimum 7 lb-in. Other levers available. See catalog 900CT007. For inside (reverse) roller option at no charge, replace 7 with 7X. (Ex: 7AN changes to 7XAN.) Table.: Specialty Arms (9007 prefix is not required on lever catalog numbers) Description Style 7D adjustable length -/8" to -/8"0.75" diameter, /" wide, metal roller Style 7DN adjustable length -/8" to -/8"0.75" diameter, /" wide, nylon roller Style 7S spring nylon, " rod, 0." diameter Style 7N nylon rod, 5" long, 0." diameter Note: Lever tightening torque for mounting the lever on the shaft: minimum 7 lb-in. Catalog Number 7D 7DN 7S 7N Male plug (face) pin-outs 9007MS0S008 C N.C. # # N.O. # N.O. #5 N.C. # # C # GND G # N.C. # Keys N.O. # G # GND N.O. # KEY # GND N.C. # KEY # N.O. N.C. # # Option 5 (MS only)dc Option 55 (ML only)dc Option (MS only)ac or DC ( Amps) Note: DC connectors are rated A, 50 Vac/Vdc. C # N.O. # Option 8 (MS only)ac C # Key N.C. # Option 8 (MS only)ac 0 Schneider Electric -9

10 Osisense Limit Switches Miniature, Metal XCMD Modular Refer to Catalog 900CT007 Thermoplastic roller lever plunger, horizontal actuation ZCE ZCE 7 ZCE 8 ZCE Side metal plunger, adjustable ZCE Thermoplastic roller lever plunger, vertical actuation Side metal plunger Thermoplastic roller lever plunger, horizontal or vertical actuation Side steel roller plunger, horizontal Retractable steel roller lever plunger Side steel roller plunger, vertical Side steel ball bearing plunger ZCE ZCE ZCE 5 ZCE M with metal end plunger M with steel roller plunger M with steel end plunger with elastomer boot ZCE F0 ZCE F ZCE G Steel roller plunger Steel roller plunger with elastomer boot Spring rod with thermoplastic end Spring rod Cat s whisker ZCE 0 ZCE 9 available with silicon boot ZCE A ZCE 07 ZCE 08 ZCE 0 Metal end plunger Metal end plunger with elastomer boot Steel ball bearing plunger ZCE 0 ZCE ZCE ZCE Metal end plunger, adjustable Side cat s whisker ZCE 7 Body with -pole N.C. + N.O. snap action contact Body with -pole N.C. + N.C. snap action contact Body with -pole N.C. + N.O. break before make, slow break contact Body with -pole N.C. + N.C. + N.O. break before make, slow break contact Body with -pole N.C. + N.C. + N.O. snap action contact ZCM D ZCM D9 ZCM D5 ZCM D7 ZCM D9 Bodies with precabled contacts ZCM DL ZCM DL ZCM DL5 Bodies with precabled contacts ZCM D9L ZCM D9L ZCM D9L5 Bodies with precabled contacts ZCM D5L ZCM D5L ZCM D5L5 Bodies with precabled contacts ZCM D7L ZCM D7L ZCM D7L5 Bodies with precabled contacts ZCM D9L ZCM D9L ZCM D9L5 () () () () (). Pre-cabled connection components: replace the in the catalog number with the required cable length in meters, either,,, 5, 7 or 0. Example: ZCMCL becomes ZCMCL7 for a 7 m (.0 ft) cable. Note: only cable lengths of, and 5 m (.,., and. ft) are available for pre-cabled connection components ZCMC7L and ZCMC9L Schneider Electric

11 Osisense Limit Switches Miniature, Metal XCMD Modular Refer to Catalog 900CT007 Dimensions: mm (in.) Round rod lever, steel, Ø (0.) L = (.9) ZCY 5 Ceramic roller lever Spring lever with thermoplastic end Square rod lever, steel, U (0.) L = (.9) ZCY 5 ZCY 55 ZCY 59 Spring rod lever, metal Round rod lever, glass fiber, Ø (0.) L = (.9) Round rod lever, thermoplastic, Ø (0.) L = 00 (7.87) ZCY ZCY 8 ZCY 9 Spring return for actuation from left AND right ZCE 0 Variable length thermoplastic roller lever, with pliable lever ZCY ZCY 5 ZCY ZCY 8 Thermoplastic roller lever, track 0/ (0.79/.) Variable length thermoplastic roller lever Steel roller lever, track 0/ (0.79/.) Variable length steel roller lever Steel ball-bearing mounted roller lever, track 0/ (0.79/.) Variable length steel roller lever, with pliable lever Thermoplastic roller lever, track / (0.9/.) Steel roller lever, track / (0.9/.) ZCY 8 ZCY 9 ZCY ZCY ZCY Stay put for actuation from left AND right ZCE 09() Steel ball-bearing mounted roller lever, track / (0.9/.) Thermoplastic roller lever, track /9 (0./) ZCY 7 ZCY 5 ZCY ZCY Forked arm with rollers, track, track /5 (0.8/.8) Steel roller lever, track /9 (0./) Steel ball-bearing mounted roller lever, track /9 (0./) Forked arm with rollers, track, track 8 (.0) ZCY ZCY 7 Pre-cabled bodies with -pole, N.C. + snap action contact ZCM DL ZCM DL ZCM DL5 Bodies with integral connector, with -pole snap action contact: N.C. + N.O., M 5-pin connector ZCM DC N.C. + N.C., M 5-pin connector ZCM D9C C/O, M -pin connector ZCM DM Body with 7/8" UN 5-pin connector on 0.8 m (. ft) flying lead, with -pole N.C. + N.O. snap action contact ZCM DL08U78 Body with M 5-pin connector on 0.8 m (. ft) flying lead, with -pole N.C. + N.O. snap action contact ZCM DL08R. Can only be used on ZCMD5 bodies. 0 Schneider Electric -

12 Osisense Limit Switches Metal and Plastic XCK Modular Refer to Catalog 900CT007 Thermoplastic roller lever plunger, horizontal actuation ZCE ZCE 7 ZCE 8 ZCE Side metal plunger, adjustable ZCE Thermoplastic roller lever plunger, vertical actuation Side metal plunger Thermoplastic roller lever plunger, horizontal or vertical actuation Side steel roller plunger, horizontal Retractable steel roller lever plunger Side steel roller plunger, vertical Side steel ball bearing plunger ZCE ZCE ZCE 5 ZCE M8 with metal end plunger M8 with steel roller plunger ZCE H0 ZCE H Steel roller plunger Steel roller plunger with elastomer boot Spring rod with thermoplastic end Spring rod Cat s whisker ZCE 0 ZCE 9 ZCE 07 ZCE 08 ZCE 0 Metal end plunger Metal end plunger with elastomer boot Steel ball bearing plunger Metal end plunger, adjustable Side cat s whisker ZCE 0 ZCE ZCE ZCE ZCE 7 Plastic bodies with integral M connector, with N.C. + N.O. snap action contact ZCP M N.C. + N.C. snap action contact ZCP 9M Plastic bodies with contacts () for use with cable entry (see below) Plastic bodies with contacts () with cable entries ISO M x Pg / NPT Pg conduit entries convert to /" NPT using adapter DE9RA0 (included) Conduit entry, plastic: ZCP EP ISO M x ZCP EP0 ISO M0 x ZCP EG Pg ZCP EG Pg ZCP EN /" NPT ZCP EF PF / (G /). For further details, see catalog 900CT Schneider Electric

13 Osisense Limit Switches Metal and Plastic XCK Modular Refer to Catalog 900CT007 Dimensions: mm (in.) Round rod lever, steel, Ø (0.) L = (.9) ZCY 5 Ceramic roller lever Spring lever with thermoplastic end Square rod lever, steel, U (0.) L = (.9) ZCY 5 ZCY 55 ZCY 59 Spring rod lever, metal Round rod lever, glass fiber, Ø (0.) L = (.9) Variable length thermoplastic roller lever, Ø 50 (.97) Round rod lever, thermoplastic, Ø (0.) L = 00 (7.87) Variable length thermoplastic roller lever, Ø 50 (.97), with adjustable track ZCY ZCY 8 ZCY 9 ZCY 9 ZCY 9 Spring return, for actuation from left AND right ZCE 0 Variable length thermoplastic roller lever, with pliable lever ZCY ZCY 5 ZCY ZCY 8 Thermoplastic roller lever, track: /0 (0.9/7) Variable length thermoplastic roller lever Steel roller lever, track: /0 (0.9/7) Variable length steel roller lever Steel ball-bearing mounted roller lever, track: /0 (0.9/7) Variable length steel roller lever, with pliable lever Thermoplastic roller lever, track: 9/ (./.) Thermoplastic roller lever, Ø 50 (.97) ZCY 9 Steel roller lever, track: 9/ (./.) ZCY 8 ZCY 9 ZCY ZCY ZCY Stay put, for actuation from left AND right () ZCE 09 Steel ball-bearing mounted roller lever, track: 9/ (./.) Thermoplastic roller lever, track: / (0.8/.7) ZCY 7 ZCY 5 ZCY ZCY Forked arm with rollers, track, track: 5/9 (0.98/) Steel roller lever, track: / (0.8/.7) Steel ball-bearing mounted roller lever, track: / (0.8/.7) Forked arm with rollers, track, track: (.) ZCY ZCY 7 Metal bodies with integral M connector, with: N.C. + N.O. snap action contact ZCD M N.C. + N.C. snap action contact ZCD 9M Metal bodies with contacts () for use in conjunction with cable entry (see below) ZCD Conduit entry, metal: ZCD EP ISO M x ZCD EP0 ISO M0 x ZCD EG Pg ZCD EG Pg ZCD EN /" NPT ZCD EF PF / (G/). For further details, see catalog 900CT Schneider Electric -

14 Modular, Miniature and Compact Miniature, Precabled Limit Switches, Metal Table.: XCMD Modular and XCMN Non-Modular OsiSense XCMD, XCMN BK BK WH BK BK WH BU BN BU BN GN-YE GN-YE -pole contact N.C. + N.O. snap action -pole contact N.C. + N.O. slow break Steel Roller Plunger XCMD, XCMN, XCKD, XCKP Complete Switches Refer to Catalog 900CT007 Plastic Roller Lever Variable Length Plastic Roller Lever M Head Steel Roller Plunger Cat Whisker End Plunger (non-modular) Actuation speed (m/s) Switches conforming to IEC section yes yes yes yes no yes Degree of protection conforming to IEC 059 IP and IP7 IP and IP7 IP and IP7 IP and IP7 IP and IP7 IP5 Rated operational characteristics Vac ; B 00 (Ue = 0 V, Ie = A) / Vdc ; R 00 (Ue = 50 V, Ie = 0. A) Cable entry pre-cabled, adjustable direction, length = m (other lengths available on request) pre-cabled length = m Mounting holesin. (mm) 0.79 (0) 0.79 (0) 0.79 (0) 0.79 (0) 0.79 (0) 0.79 (0) Body dimensionsin. (mm), W x D x H.8 x 0. x. (0 x x 59).8 x 0. x. (0 x x 59).8 x 0. x. (0 x x 59).8 x 0. x. (0 x x 59).8 x 0. x. (0 x x 59).8 x 0. x. (0 x x 59) Ordering information Cat. No. Cat. No. Cat. No. Cat. No. Cat. No. Cat. No. -pole, N.C. + N.O. snap action XCMD0L XCMDL XCMD5L XCMDFL XCMD0L XCMN0L -pole, N.C. + N.O. break before make, slow break XCMD50L XCMD5L XCMD55L XCMD5FL XCMD50L Exploded view page -0 Compact, Modular Limit Switches, Metal or Plastic Table.7: XCKD and XCKP Compact, 0 mm Wide, Conforming to Standard EN 5007 OsiSense XCKP Metal End Plunger Plastic Roller Lever Horizontal Actuation M8 Head Metal End Plunger Plastic Roller Lever Variable Length Plastic Roller Lever Rubber Roller Lever Ø 50 mm Cat Whisker -pole contact N.C. + N.O. snap action -pole contact N.C. + N.O. slow break Actuation speed (m/s) Switches conforming to IEC yes yes yes yes yes yes no section Degree of protection conforming to IEC IP and IP7 IP and IP7 IP and IP7 IP and IP7 IP and IP7 IP and IP7 IP and IP7 Rated operational characteristics Vac ; A 00 (Ue = 0 V, Ie = A) / Vdc ; Q 00 (Ue = 50 V, Ie = 0.7 A) Cable entry tapped entry for /" NPT Mounting holes (mm) 0 0 M8 x Body dimensions (mm) W x D x H 0 x 0 x 7 0 x 0 x 7 0 x 0 x 7 0 x 0 x 7 0 x 0 x 7 0 x 0 x 7 0 x 0 x 7 Ordering information Cat. No. Cat. No. Cat. No. Cat. No. Cat. No. Cat. No. Cat. No. XCKD Metal, 0 mm Wide -pole, N.C.+ N.O. XCKD0N XCKDN XCKDH0N XCKD8N XCKD5N XCKD9N XCKD0N snap action -pole, N.C.+ N.O. break before make, slow break XCKD50N XCKD5N XCKD5H0N XCKD58N XCKD55N XCKD59N XCKD50N XCKP Plastic, 0 mm Wide, Double Insulated -pole, N.C.+ N.O. XCKP0N XCKPN XCKPH0N XCKP8N XCKP5N XCKP9N XCKP0N snap action -pole, N.C.+ N.O. break before make, slow break XCKP50N XCKP5N XCKP5H0N XCKP58N XCKP55N XCKP59N XCKP50N Exploded view page Schneider Electric

15 Modular, Miniature and Compact Compact Limit Switches with Cable Entries and Modular Head XCKT, XCDR, XCPR Complete Switches Refer to Catalog 900CT007 Table.8: XCKT Compact, Plastic, Cable Entries, Standard, 0 mm OsiSense Metal End Plunger Metal Roller Plunger Plastic Roller Lever XCKT -pole contact N.C. + N.O. snap action Actuation speed (m/s) Switches conforming to IEC section yes yes yes Degree of protection conforming to IEC 059 IP and IP7 IP and IP7 IP and IP7 Rated operational characteristics Vac ; A 00 (Ue = 0 V, Ie = A) / Vdc ; Q 00 (Ue = 50 V, Ie = 0.7 A) Cable entry Two Pg cable entries. One /" NPT adapter, DE9RA0, is included. Mounting holesin. (mm) 0.79 or 7 (0 or 0) 0.79 or 7 (0 or 0) 0.79 or 7 (0 or 0) Body dimensionsin. (mm), W x D x H. x.8 x. (0 x 0 x ). x.8 x. (0 x 0 x ). x.8 x. (0 x 0 x ) Ordering information Cat. No. Cat. No. Cat. No. Complete switch -pole, N.C. + N.O. snap action XCKT0N XCKT0N XCKT8N Modular, Compact Limit Switches with Manual Reset Table.9: XCDR and XCPR Compact, Metal or Plastic, with Manual Reset, 0 mm OsiSense Plastic Roller Lever Metal End Plunger XCDR and XCPR Horizontal Actuation Plastic Roller Lever Vertical Actuation Actuation speed (m/s) 0.5 Switches conforming to IEC section yes yes yes Degree of protection conforming to IEC 059 IP and IP7 IP and IP7 IP and IP7 Rated operational characteristics Vac ; A 00 (Ue = 0 V, Ie = A) / Vdc ; Q 00 (Ue = 50 V, Ie = 0.7 A) Cable entry tapped entry for /" NPT Mounting holesin. (mm) 0.79 (0) 0.79 (0) 0.79 (0) Body dimensionsin. (mm), W x D x H.8 x.8 x.7 (0 x 0 x 95).8 x.8 x.7 (0 x 0 x 95).8 x.8 x.7 (0 x 0 x 95) Ordering information Cat. No. Cat. No. Cat. No. XCDR Metal -pole, N.C. + N.O. snap action XCDR0N XCDRN XCDR7N Complete switch -pole, N.C. + N.O. break before make, slow break XCDR50N XCDR5N XCDR57N XCPR Plastic, Double Insulated Complete switch -pole, N.C. + N.O. snap action XCPR0N XCPRN XCPR7N -pole, N.C. + N.O. break before make, slow break XCPR50N XCPR5N XCPR57N 0 Schneider Electric -

16 Modular, Miniature and Compact Common Head and Levers for XCMD, XCKD, XCKP, XCKT Table.0: Metal Plunger and Multi-Directional Heads Metal End Plunger Metal End Plunger with Elastomer Protective Boot Steel Roller Plunger Common Heads and Levers Refer to Catalog 900CT007 Retractable Steel Roller Lever Plastic Roller Lever, Horizontal Actuation Plastic Roller Lever, Vertical Actuation Cat. No. Cat. No. Cat. No. Cat. No. Cat. No. Cat. No. ZCE0 ZCE ZCE0 ZCE ZCE ZCE7 Bushing Mounted Bushing Mounted Bushing Mounted Bushing Mounted M Head Metal Plungerb M8 Head Metal Plungera M Head Steel Roller Plungera M8 Head Steel Roller Plungera Spring Lever Spring Lever with Plastic End Cat Whisker Cat. No. Cat. No. Cat. No. Cat. No. Cat. No. Cat. No. Cat. No. ZCEF0 ZCEH0 ZCEF ZCEH ZCE08 ZCE07 ZCE0 Table.: Metal Rotary Heads and Levers Rotary Head without Lever, Spring Return, for Actuation from RH or LH Side Rotary Head without Lever, Stay Put, for Actuation from RH or LH Side c Plastic Roller Lever, Track: / mm (ZCMD) 9/ mm (ZCD/P/T)b Steel Roller Lever, Track: / mm (ZCMD) 9/ mm (ZCD/P/T)b Plastic Roller Lever, Track: /9 mm (ZCMD) / mm (ZCD/P/T)b Steel Roller Lever, Track: /9 mm (ZCMD) / mm (ZCD/P/T)b Plastic, Roller Lever, Track: 0/ mm (ZCMD) /0 mm (ZCD/P/T)a Cat. No. Cat. No. Cat. No. Cat. No. Cat. No. Cat. No. Cat. No. ZCE0 ZCE09 ZCY ZCY ZCY5 ZCY ZCY8 Steel Roller Lever, for Track: 0/ mm (ZCMD) /0 mm (ZCD/P/T)a Ceramic Roller Lever Variable Length, Rigid Plastic Roller Lever Variable Length, Bendable Plastic Roller Lever Variable Length, Rigid Steel Roller Lever Variable Length, Bendable Steel Roller Lever Metal Spring Lever Cat. No. Cat. No. Cat. No. Cat. No. Cat. No. Cat. No. Cat. No. ZCY9 ZCY ZCY5 ZCY ZCY ZCY8 ZCY9 Recommended for Use with ZCE09 Head Recommended for Use with ZCE09 Head Plastic Roller Lever Ø 50 mm Adjustable Plastic Roller Lever Ø 50 mm Square Steel Rod Lever, U mm, length = mm Round, Glass Fiber Rod Lever, Ø mm length = mm Round Plastic Rod Lever, Ø mm, length = 00 mm Forked Lever Arm with Tracks: 5/9 mm Forked Lever Arm with Track: mm Cat. No. Cat. No. Cat. No. Cat. No. Cat. No. Cat. No. Cat. No. ZCY9 ZCY9 ZCY5 ZCY55 ZCY59 ZCY ZCY7 a Recommended for use with body ZCD... / ZCP... / ZCT... b Recommended for use with body: ZCMD... c Can only be used on ZCMD5 bodies. - 0 Schneider Electric

17 Modular, Miniature and Compact Bodies Body/Contact Assemblies and Connection Components Refer to Catalog 900CT007 NOTE: Metal components must be used with metal bodies. Plastic components must be used with plastic bodies. Table.: Miniature, Metal Body/Contact Assemblies Type of contact -pole N.C. + N.O. Snap action BK BK WH BU BN -pole N.C. + N.C. Snap action GN-YE -pole N.C. + N.C. + N.O. Snap action BK RD BU BK WH RD WH BN -pole N.C. + N.C. + N.O. + N.O. Snap action GN-YE BK BK WH -pole N.C. + N.O. Slow break BU BN GN-YE BK -pole N.C. + N.C. + N.O. Slow break RD BU BK WH RD WH BN GN-YE -pole N.C. + N.O. Snap action 5-pin connector BK BK WH BU BN GN-YE SPDT contact Snap action -pin connector BK BK WH BU BN GN-YE Cat. No. Cat. No. Cat. No. Cat. No. Cat. No. Cat. No. Cat. No. Cat. No. Metal body ZCMD ZCMD9 ZCMD9 ZCMD ZCMD5 ZCMD7 ZCMDC ZCMDM Table.: Connection of Miniature Body/Contact Assemblies Specific pre-cabled connection components Length (m) Cat. No. Cat. No. Cat. No. Cat. No. Cat. No. ZCMCL ZCMC9L ZCMC9L ZCMC5L ZCMC7L ZCMCL ZCMC9L ZCMC9L ZCMC5L ZCMC7L 5 ZCMCL5 ZCMC9L5 ZCMC9L5 ZCMC5L5 ZCMC7L5 Exploded view page -0 = N.C. = N.O. 5 = Ground = Common = N.C. = Ground = N.O. Table.: Compact, Metal or Plastic Body/Contact Assemblies Type of contact -pole N.C. + N.O. Snap action -pole N.C. + N.O. Snap action -pole N.C. + N.C. + N.O. Snap action -pole N.C. + N.O. Slow break -pole N.C. + N.O. Snap action -pole N.C. + N.O. Snap action -pole N.C. + N.O. Snap action -pole N.C. + N.O. Snap action -pole N.C. + N.O. Slow break Cat. No. Cat. No. Cat. No. Cat. No. Cat. No. Cat. No. Cat. No. Cat. No. Cat. No. Metal ZCD ZCD9 ZCD9 ZCD5 ZCDM Plastic ZCP ZCP9 ZCP9 ZCP5 ZCPD ZCPM ZCTP ZCT5P Table.5: Connection of Compact Body/Contact Assemblies Interchangeable cable entry ISO M ISO M0 Pg Pg / NPT PF / NPSF Deutsch Connector Cat. No. Cat. No. Cat. No. Cat. No. Cat. No. Cat. No. Cat. No. Metal ZCDEP ZCDEP0 ZCDEG ZCDEG ZCDEN ZCDEF Plastic ZCPEP ZCPEP0 ZCPEG ZCPEG ZCPEN ZCPEF ZCPED Note: Plastic conduit entries shown. Order plastic conduit entries for plastic bodies (XCKP/ZCP). Order metal conduit entries (chrome color) for metal bodies (XCKD/ZCD). Metal conduit entries do not fit on plastic bodies. Exploded view page - 0 Schneider Electric -7

18 Light Duty Compact, Plastic, Non-Modular Table.: XCKN Compact Plastic, Non-Modular, 0 mm Wide Osisense Limit Switches pole snap action pole break before make, slow break Metal end plunger XCKN and XCNR Complete Switches Refer to Catalog 9007CT007 Plastic roller plunger for lateral cam approach Switch actuation On end By 0 cam Type of actuation Plastic roller plunger for cross cam approach Thermoplastic roller-lever plunger Horizontal actuation in direction Vertical actuation in direction Maximum actuation speed 0.5 m/s (. ft/s) 0. m/s (0.99 ft/s) 0. m/s (.8 ft/s) For tripping N (.7 lb) N (.70 lb) N ( lb) Minimum force of torque For positive opening 0 N (.75 lb) 0 N (.50 lb) 0 N (.5 lb) Weight, kg (lb) 0.05 (0.) 0.05 (0.) 0.05 (0.) (0.) (0.) Ordering Information (sold in packs of 0) Cat. No. Cat. No. Cat. No. Cat. No. Cat. No. pole N.C. + N.O. snap action XCKN0P0 XCKN0P0 XCKN0P0 XCKNP0 XCKN7P0 pole N.C. + N.O., break before make, slow break XCKN50P0 XCKN50P0 XCKN50P0 XCKN5P0 XCKN57P0 pole N.C. + N.C. snap action XCKN90P0 XCKN90P0 XCKN90P0 XCKN9P0 XCKN97P0 pole snap action pole break before make, slow break Rotary, thermoplastic roller-lever Rotary, variable length thermoplastic roller-lever Rotary, thermoplastic roller-lever, Ø 50 mm Rotary, variable length, thermoplastic roller-lever, Ø 50 mm Multi-directional, spring rod Switch actuation By 0 cam By any moving part Multi-directional, cat s whisker Type of actuation Maximum actuation speed m/s (.9 ft/s) m/s (.8 ft/s), any direction Minimum force For tripping 0. N m (0.89 lb-in) 0. N m (0. lb-in) of torque For positive opening 0. N m (. lb-in) Weight, kg (lb) (0.87) (0.98) 0.0 (0.) 0. (0.5) (0.87) (0.) Ordering Information (sold in packs of 0) Cat. No. Cat. No. Cat. No. Cat. No. Cat. No. Cat. No. pole N.C. + N.O. snap action XCKN8P0 XCKN5P0 XCKN9P0 XCKN9P0 XCKN08P0 XCKN0P0 pole N.C. + N.O., break before make, slow break XCKN58P0 XCKN55P0 XCKN59P0 XCKN59P0 XCKN508P0 XCKN50P0 pole N.C. + N.C. snap action XCKN98P0 XCKN95P0 XCKN99P0 XCKN99P0 XCKN908P0 XCKN90P0 Table.7: XCNR Compact Plastic, Non-Modular, with Manual Reset, 0 mm Wide pole N.C. + N.O. pole N.C. + N.C. Metal end plunger Plastic roller plunger Switch actuation On end By 0 cam Thermoplastic roller-lever plunger Horizontal actuation in Vertical actuation in direction direction Rotary head, thermoplastic roller-lever plunger Type of actuation Maximum actuation speed 0.5 m/s (. ft/s) 0. m/s (0.99 ft/s) 0. m/s (.8 ft/s) m/s (.9 ft/s) For tripping N (.7 lb) N (.70 lb) N ( lb) 0. N m (0.89 lb-in) Minimum force of torque For positive opening 0 N (.7 lb) 0 N (.50 lb) 0 N (.5 lb) 0. N m (. lb-in) Weight, kg (lb) (0.8) (0.8) (0.9) (0.0) 0.00 (0.) Ordering Information (sold in packs of 0) Cat. No. Cat. No. Cat. No. Cat. No. Cat. No. pole N.C. + N.O.snap action XCNR0P0 XCNR0P0 XCNRP0 XCNR7P0 XCNR8P0 pole N.C. + N.O. break before make, slow break XCNR50P0 XCNR50P0 XCNR5P0 XCNR57P0 XCNR58P0 pole N.C. + N.C. snap action XCNR90P0 XCNR90P0 XCNR9P0 XCNR97P0 XCNR98P0 Table.8: Cable Entries and Contact Configurations M0 Order with suffix P0 for entry tapped to M0 x mm for ISO cable entry. Clamping capacity 7 to mm (0.8 to 0.5 in.) Cable entry Pg Replace P0 suffix with Gsuffix, 8. x. / NPT Replace P0 suffix with G suffix. Order /" NPT adapter DE90 Other cable entries For other cable entries, including complete switches with ISO M x or PF / (G /) cable entry, please consult your local sales office. Other contact configurations For other - and -pole configurations, please consult your local sales office. Function diagrams See catalog 900CT Schneider Electric

19 Light Duty Industrial, Standard Body, Plastic XCKS Standard Body, Plastic, Double Insulated XCKS, Double Insulated Refer to Catalog 900CT007 Table.9: Environmental Specifications Conforming to standards Products IEC , EN , UL 508, CSA C- n Machine assemblies IEC 00-, EN 00- Approvals UL, CSA, CCC Ambient air temperature For operation - 5 to +70 C (- to +8 F) For storage - 0 to +70 C (-0 to +8 F) Vibration resistance Conforming to IEC gn (0 500 Hz) Shock resistance Conforming to IEC gn ( ms) Electric shock protection Class II conforming to IEC 0 and NF C 0-00 Degree of protection IP 5 conforming to IEC 059; IK 0 conforming to EN 500 Repeat accuracy 0.05 mm on the tripping points, with million operating cycles for head with end plunger Cable entry Depending on model Tapped entry for PG conduit thread. To convert to /" NPT, use adapter DE9RA. For ISO M0 x, add H9 to the end of the catalog number. Example: XCKS0 becomes XCKS0H9. Materials Plastic (body and head) Table.0: Selection, Plunger and Rotary Heads -pole N.C. + N.O. snap action Form B a Form C a Form A a Form D a -pole N.C. + N.O. break before make, slow break -pole N.C. + N.C. Metal end plunger Steel roller plunger Thermoplastic roller lever c Elastomer roller lever, Ø 50 mm (.97 in.) c Variable length thermoplastic roller lever c Variable length elastomer roller lever, Ø 50 mm (.97 in.) c Round thermoplastic rod lever, Ø mm (0. in.) d e Ordering Informationb Cat. No. Cat. No. Cat. No. Cat. No. Cat. No. Cat. No. Cat. No. -pole N.C. + N.O. snap action XCKS0 XCKS0 XCKS XCKS9 XCKS XCKS9 XCKS9 (XESP5) -pole N.C. + N.O. break before make, slow break (XENP5) XCKS50 XCKS50 XCKS5 XCKS59 XCKS5 XCKS59 XCKS559 -pole N.C. + N.C. snap action (XESP) -pole N.C. + N.C. simultaneous, slow break (XENP) ZCKS9 + ZCKD0 ZCKS7 + ZCKD0 ZCKS9 + ZCKD0 ZCKS7 + ZCKD0 ZCKS9 + ZCKD ZCKS7 + ZCKD ZCKS9 + ZCKD9 ZCKS7 + ZCKD9 ZCKS9 + ZCKD ZCKS7 + ZCKD ZCKS9 + ZCKD9 ZCKS7 + ZCKD9 Weight, kg (lb) (0.09) 0.05 (0.) 0. (0.0) 0.0 (0.) 0.5 (0.) 0.5 (0.) 0.0 (0.) Contact operation N.C. contact with positive opening operation, when properly mounted and using a conforming operator. Table.: Specifications ZCKS9 + ZCKD59 ZCKS7 + ZCKD59 Switch actuation On end By 0 cam By any moving part Type of actuation Maximum actuation speed 0.5 m/s (. ft/s) m/s (.9 ft/s) m/s (.8 ft/s) Minimum For tripping N (.7 lb) N (.70 lb) 0. N m (. lb-in) force or For positive torque opening 5 N (0. lb) N (8.09 lb) 0. N m (. lb-in) Cable entry entry tapped M0 x mm for ISO cable entry, clamping capacity 7 to mm (0.8 to 0.5 in.) To convert PG to /" NPT, use adapter DE9RA. For ISO M0 x, add H9 to the end of the catalog number. Example: XCKS0 becomes XCKS0H9. a Form conforming to EN 500. See page /9 of catalog 900CT007. b Switches with gold contacts or eyelet type connections: please consult your local sales office. c Adjustable throughout 0 in 5 steps, or in 90 steps by reversing the notched washer. d Adjustable throughout 0 in 5 steps, or in 5 steps by reversing the lever mounting. e Value taken with actuation by moving part at 00 mm (.9 in.) from the mounting. 0 Schneider Electric -9

20 Osisense Limit Switches XC Standard, Classic XCKM and XCKL, Metal, Variable Composition Refer to Catalog 900CT007 Spring-rod lever with thermoplastic end () Spring-rod lever, metal () Variable-length thermoplastic roller lever () ZCKD8 ZCKD9 ZCKD ZCKD59 Round rod lever, thermoplastic,ø mm() Cat s whisker Spring rod ZCKD0 ZCKD08 Thermoplastic roller lever () Steel roller lever () Steel ball bearing mounted roller lever () ZCKD ZCKD ZCKD7 Thermoplastic roller lever, direction of actuation Thermoplastic roller lever plunger with protective boot, direction of actuation Steel roller lever plunger, direction of actuation Steel roller lever plunger with protective boot, direction of actuation ZCKD ZCKD9 ZCKD ZCKD9 Metal end plunger Metal end plunger with protective boot Steel roller plunger Steel roller plunger with protective boot ZCKD0 ZCKD09 ZCKD0 ZCKD09 Body with -pole contact and one /" NPT cable entry using the included adapter, DE9RA0 ZCKL / L5 / L / L7 ZCKL8H7-0 0 Schneider Electric

21 Osisense Limit Switches XC Standard, Classic XCKM and XCKL, Metal, Variable Composition Refer to Catalog 900CT007 Square-rod lever, steel, Ø mm L = mm () ZCKY5 Round rod lever, glass fibre, Ømm L = mm () ZCKY55 Round rod lever, thermoplastic,ø mm L = 00 mm () ZCKY59 Spring-rod lever, with thermoplastic end () Spring-rod lever, metal() ZCKY8 ZCKY9 Variable length elastomer roller lever, Ø 50 mm () Elastomer roller lever, Ø 50 mm () Variable length thermoplastic roller lever () Variable length steel roller lever () ZCKY ZCKY ZCKY9 ZCKY9 Thermoplastic roller lever () Steel roller lever () Steel ball bearing mounted roller lever () ZCKY ZCKY ZCKY For actuation from left AND right or from left OR right ZCKG00 ZCKD05 Head assuring positive opening operation when used with a conforming lever. () Adjustable throughout 0 in 5 steps, or in 90 steps by reversing the notched washer. () Adjustable throughout 0 in 5 steps, or in 5 steps by reversing the lever mounting. 0 Schneider Electric -

22 Compact General Duty XCKL Complete Switches Refer to Catalog 900CT007 XCKL0H7 XCKL XCKL is a compact, general-duty limit switch for applications such as machine tools and material handling. Table.: Specifications Rated Power (conforms to IEC 97-5-, duty categories AC and DC) Temperature range - to +8 F (-5 to +70 C) The minimum temperatures listed are based on the absence of freezing moisture or water. Enclosure rating NEMA Type,,,, IP Vibration resistance 5 G (0 500 Hz), conforming to IEC 8-- Shock resistance 50 G, conforming to IEC 8--7 Repeatability 0.00 in. (0.05 mm) Cable entry Standard: Pg with DE9RA0 adapter for /" NPT conduit entry Contact Characteristics Rated thermal current 0 A Rated insulation voltage 00 Vac and dc (A00 and Q00) Contact resistance (max.) 5 mω Cable (max.) x # AWG ( mm ) per terminal Short circuit protection (customer supplied) 0 A fuse type SC. Outside U.S. use gl or N. Complete Switches Table.: Lever Operated Description a Functional Diagram Operating Torque/Force Contact Configuration Catalog Number Programmable head CW and/or CCW snap action Delrin roller lever adjustable in 5 or 5 in increments (reversible mounting). 58 (P) oz-in SPDT (N.O. + N.C.) snap XCKL00H7. oz-in SPDT (N.O. + N.C.) slow XCKL500H7 XCKL00H7 Adjustable length roller lever adjustable in 5 or 5 increments (reversible mounting). 58 (P) oz-in SPDT (N.O. + N.C.) snap XCKL00H7. oz-in SPDT (N.O. + N.C.) slow XCKL500H7 CW and CCW, Delrin roller lever 58 (P) oz-in SPDT (N.O. + N.C.) snap XCKLH7. oz-in SPDT (N.O. + N.C.) slow XCKL5H7 One way lever-delrin roller (P) oz-in SPDT (N.O. + N.C.) snap XCKLH7 5. oz-in SPDT (N.O. + N.C.) slow XCKL5H7 Table.: Omnidirectional XCKLH7 Description a Functional Diagram Operating Torque/Force Contact Configuration Catalog Number Wobble stick-steel rod oz-in SPDT (N.O. + N.C.) snap XCKL0H7.8 oz-in SPDT (N.O. + N.C.) slow XCKL50H7 Table.5: Plunger Operated Description a Functional Diagram Operating Torque/Force Contact Configuration Catalog Number XCKL0H7 Rod plunger.07.8(p) oz SPDT (N.O. + N.C.) snap XCKL0H7 5. oz SPDT (N.O. + N.C.) slow XCKL50H7 Roller plunger (P).0 5. oz SPDT (N.O. + N.C.) snap XCKL0H7 5. oz SPDT (N.O. + N.C.) slow XCKL50H7 a Diagrams shown are for XCKL. Exploded view page -0 Lever arms page - XCKL0H7 File CCN E98 NKCR File Class LR087-0 Acceptable Wire Sizes: AWG Recommended Terminal Clamp Torque: lb-in 0 Schneider Electric

23 Compact General Duty XCKL Components Refer to Catalog 900CT00 ZCKLH7, ZCKL5H7 ZCKG00H7 ZCKD,,7H7 ZCKD0H7 ZCKD0H7 ZCKD,H7 ZCKYH7 ZCKYH7 Table.: BodiesElectric Components Contacts Catalog Number Body: Single pole, double break, N.O. + N.C. Silver ZCKLH7 Snap action, positive opening, same polarity Gold Flashed ZCKL8H7 Body: Single pole, double break, N.O. + N.C. Slow make, slow break isolated Silver ZCKL5H7 Table.7: Rotary Heads Components Catalog Number Programmable headb CW and/or CCW Select lever arm separately ZCKG00 Offset Delrin roller levera ZCKD Offset steel roller levera ZCKD Offset ball-bearing roller levera ZCKD7 a Replacement arms are not available separately. Order complete head as a replacement. b See page. Table.8: Plunger Heads Description Rod plunger Booted rod plunger Roller plunger Booted roller plunger One-way leverdelrin roller Steel roller Catalog Number ZCKD0 ZCKD09 ZCKD0 ZCKD09 ZCKD ZCKD Table.9: Omnidirectional Heads Description Catalog Number Cat whiskersteel rodc ZCKD0 Wobble springsteel springc ZCKD08 c Replacement cat whiskers and wobble extensions are not available separately. Order complete head as a replacement. Table.0: Replacement Parts Description Contact block for ZCKL Contact block for ZCKL5 Gold flashed contact block for ZCKL8 Pg to /" NPT conduit entry adapter Catalog Number XESP5 XENP5 XESP58 DE9RA0 Building a Complete Switch Complete Switch = Body (with contact assembly) + Head + Lever Examples: Body ZCKLH7 + Head ZCKD = XCKLH7 Body ZCKL5 H7+ Head ZCKD0 = XCKL50H7 Body ZCKLH7 + Head ZCKG00 + Lever ZCKY = Note: XCKL00H7 Some combinations are not available as complete switches. ZCKY5H7 ZCKY8H7 ZCKY7H7 ZCKY9H7 Table.: Levers (for use with ZCKG00 heads onlythese arms will not fit ZCKD heads) Description Size Adjustmente Increments Catalog Number Delrin roller 0.9 in. diameter, 0. in. wide,. in. long 5 or 5 ZCKY Steel roller 0.9 in. diameter, 0. in. wide,. in. long 5 or 5 ZCKY Ball bearing roller 0.9 in. diameter, 0. in. wide,. in. long 5 or 5 ZCKY Adjustable length Delrin rollerd 0.7 in. diameter, 0. in. wide,. in. long (max.) 5 or 90 ZCKY Steel roller 0.7 in. diameter, 0. in. wide,. in. long (max.) 5 or 90 ZCKY Steel rod, squared /8 in. side, 5. in. long (max.) 5 or 5 ZCKY5 Fiberglass rod, roundd /8 in. diameter, 5. in. long (max.) 5 or 5 ZCKY5 Steel rod, roundd /8 in. diameter, 5. in. long (max.) 5 or 5 ZCKY5 Plastic rod, roundd / in. diameter, 8. in. long (max.) 5 or 5 ZCKY59 Fork, track Delrin roller 0.9 in. diameter, 0. in. wide for ZCKE09 5 or 5 ZCKY7 Coil spring lever d. in. ( mm) 5 or 5 ZCKY8 Spring rod leverd 7.05 in. (79 mm) 5 or 5 ZCKY9 d Flexible operators do not guarantee positive opening operation. e Reverse mounting (for ZCKG00 head)the higher increment (5 or 90 ) is a positive opening contact feature which ensures no loss of mechanical effort between the actuation point and the moving contact bridge of the N.C. contact even if the lever is loosely mounted on the head shaft. Acceptable Wire Sizes: AWG Recommended Terminal Clamp Torque: lb-in ZCKG00 Programming The ZCKG00 head is field convertible to CW, CCW, or CW/CCW. Reverse Lever Mounting File CCN 59 NKCR File Class LR Schneider Electric -

24 Osisense Limit Switches Standard Industrial, Metal XCKJ Industrial Format EN 500, Fixed or Plug-in Body Refer to Catalog 900CT007 Thermoplastic roller lever plunger, direction of actuation ZCKE Side metal plunger Side steel roller plunger, horizontal () Steel roller lever plunger, direction of actuation ZCKE Side steel roller plunger, horizontal () ZCKE ZCKE ZCKE5 Spring rod Cat s whisker ZCKE08 ZCKE0 End reinforced steel roller plunger End steel roller plunger with protective boot End steel roller plunger ZCKE7 ZCKE9 ZCKE End metal plunger End steel ball bearing plunger End metal plunger with protective boot ZCKE ZCKE ZCKE9 Body with -pole contact, fixed, step, M connector () ZCKJD / J5D / JD / J7D ZCKJ8D Body with contact, cable entry for / NPT fixed, step () () ZCKJDp ZCKJ / J5 / J / J7 / J9H7 Body with contact, cable entry for / NPT fixed, step () () Body with contact, cable entry for / NPT plug-in, or step () () ZCKJ / J / JH7 ZCKJ / J8H7 Body with contact, cable entry for / NPT fixed, step () () ZCKJH7 CO snap action () Cannot be used with bodies ZCKJH7 and ZCKJH7. () For further information, see page -7. () For a cable entry tapped ISO M0 x, change H7 to H9. Example: ZCKJH7 becomes ZCKJH9. For a cable entry tapped Pg, delete H7 from the catalog number. Example: JCKJH7 becomes ZCKJ. - 0 Schneider Electric

25 Osisense Limit Switches Standard Industrial, Metal XCKJ Industrial Format EN 500, Fixed or Plug-in Body Refer to Catalog 900CT007 Square-rod lever, steel, Ø mm L = mm (5) ZCKY5 Spring lever with thermoplastic end () Round rod lever, steel, Ø mm L = mm (5) ZCKY5 ZCKY5 ZCKY59 Spring-rod lever, metal () Round rod lever, glass fibre, Ømm L = mm (5) Round rod lever, thermoplastic, Ømm L = 00 mm (5) ZCKY8 ZCKY9 Variable length thermoplastic roller lever () Variable length steel roller lever () Spring return, for actuation from left AND right or from left OR right ZCKY ZCKY ZCKE05 Thermoplastic roller lever (5) Steel roller lever (5) Steel ball bearing mounted roller lever (5) ZCKY ZCKY ZCKY Body with double-pole CO, neutral position, snap action contact cable entry for / NPT, fixed () CW, CCW (see page -) Body with double-pole CO, neutral position, snap action contact cable entry for / NPT, plug-in () CW, CCW (see page -) ZCKJ0H7 ZCKJ0H7 Stay put, for actuation from left AND right () Forked arm with thermoplastic rollers, track (5) Forked arm with thermoplastic rollers, track (5) ZCKE09 ZCKY7 ZCKY Head assuring positive opening operation when used with a conforming lever. () Adjustable throughout 0 in 5 steps, or in 90 steps by reversing the notched washer. (5) Adjustable throughout 0 in 5 steps, or in 5 steps by reversing the lever mounting. () Suitable for bodies with contacts ZCKJ / J / J / J9H7. 0 Schneider Electric -5

26 Heavy Duty / Industrial Metal Body XCKJ05H7 XCKJ Complete Switches Refer to Catalog 900CT007 XCKJ fixed body type precision switches with an SPDT configuration have direct opening contacts to meet most international standards. Table.: Specifications Rated Power (conforms to IEC 97-5-, duty categories AC and DC) Temperature range to +8 F ( 5 to +70 C); optional 0 to +8 F ( 0 to + C). The minimum temperatures listed are based on the absence of freezing moisture or water. Enclosure rating NEMA,,,,; IEC Type IP Vibration resistance 5 G (0 500 Hz), conforming to IEC 8-- Shock resistance 50 G, conforming to IEC 8--7 Repeatability (max.) in. (0.0 mm) Cable entry /" NPT standard Contact Characteristics Rated thermal current 0 A, conforming to UL 508, CSA C- No., IEC 7-, NFC -0, VDE Rated insulation voltage Non-plug-in: 00 Vac (A00) and DC (Q00) Plug-in: 00 Vac (A00) and DC (Q00) Contact resistance (max) Non-plug-in: 5 m Ω Plug-in: 5 m Ω Cable (max.) x AWG ( mm ) per terminal x # AWG for SPDT ( N.O., N.C.) Short circuit protection 0 A fuse type SC; Form I Class J or equivalent. Outside US use type gl or N. Table.: Complete Switches, XCKJ XCKJ05H7 XCKJH7 Description and Functional Diagram Non-plug-in Housings Lever operated (P) 90 Operating Torque Contact Type Direct Opening Catalog Number Delrin roller lever adjustable in 5 or 5 increments (reversible mountings). oz-in SPDT (N.O. + N.C.) Y a XCKJ05H7. oz-in SPDT ( N.O. + N.C.) N XCKJ05H7 Adjustable lengthdelrin roller lever adjustable in 5 or 90 increments. oz-in SPDT (N.O. + N.C.) N XCKJ05H7. oz-in SPDT ( N.O. + N.C.) N XCKJ05H7 Adjustable length/8 in. diameter steel rod adjustable in 5 or 5 increments. oz-in SPDT (N.O. + N.C.) N XCKJ055H7 Adjustable length/ in. plastic rod adjustable in 5 or 5 increments. oz-in SPDT (N.O. + N.C.) N XCKJ0559H7 Neutral Position One SPDT contact switch per direction. Past 0 CW, contact (- / -) switches. Past 0 CCW, contact ( / -) switches. Levers not included " 0. oz-in SPDT ( N.O. + N.C.) N ZCKJ0H7 XCKJ05H7 Plunger Operated (P).05. Rod plunger 8 oz Steel roller plunger 8 oz SPDT (N.O. + N.C.) Y a XCKJH7 SPDT (N.O. + N.C.) Y a XCKJ7H7 Plug-in Housings Lever Operated Delrin roller lever adjustable in 5 or 5 increments (reversible mountings). oz-in SPDT (N.O. + N.C.) N XCKJ05H7 Adjustable length Delrin roller lever adjustable in 5 or 90 increments. oz-in SPDT (N.O. + N.C.) N XCKJ05H7 Neutral Position One SPDT contact switch per direction. Past 0 CW, contact (- / -) switches. Past 0 CCW, contact ( / -) switches. Levers not included. XCKJ7H " 0. oz-in SPDT ( N.O. + N.C.) N ZCKJ0H7 XCKJ7H7 Plunger Operated.08" Rod plunger 8 oz SPDT (N.O. + N.C.) N XCKJH Steel roller plunger - 8 oz SPDT (N.O. + N.C.) N XCKJ7H7 05" " a Direct opening contacts meet IEC requirements for positive opening contacts. Exploded view page Schneider Electric

27 Heavy Duty / Industrial Metal Body Table.: Non-plug-in XCKJ Bodies and Options Refer to Catalog 900CT007 ZCKJH7 Non-plug-in ZCKJH7 Plug-in Silver Contacts (0 A) Direct Opening Catalog Number Step SPDT (N.O. + N.C.) Snap action Ya ZCKJH7 Step SPDT (isolated N.O. + N.C.) Slow break-before-make Ya ZCKJ5H7 Step SPDT ( N.O. + N.C.) Snap action N ZCKJH7 Step SPDT ( N.O. + N.C.) Snap action N ZCKJH7 Gold Flashed Contacts (low power circuits max. V, 0. A) Step SPDT (N.O. + N.C.) Snap action Ya ZCKJ8H7 Step SPDT ( N.O. + N.C.) Snap action N ZCKJ8H7 High Temperature: +8 F (+ C) Step SPDT (N.O. + N.C.) Snap action Ya ZCKJH7 Step SPDT (N.O. + N.C.) Snap action N ZCKJ5H7 Neutral Position SPDT ( N.O. + N.C.) Snap action N ZCKJ05H7 Table.5: Plug-in Silver Contacts (0 A) Direct Opening Catalog Number Step SPDT (N.O. + N.C.) Snap action N ZCKJH7 Step SPDT ( N.O. + N.C.) Snap action N ZCKJH7 Step SPDT ( N.O. + N.C.) Snap action N ZCKJH7 High Temperature: +8 F (+ C) Step SPDT (N.O. + N.C.) Snap action N ZCKJH7 Step SPDT ( N.O. + N.C.) Snap action N ZCKJ5H7 Neutral Position SPDT ( N.O. + N.C.) Snap action N ZCKJ05H7 Table.: Wiring Options Catalog Number Pins Suffix Mini style male receptacle ZCKJ/J/J5H7 5 pins 57 (For example, to order a ZCKJH7 body with a mini-style connector option, the part number is ZCKJ7.) ZCKJ/J/J/JH7 9 pins 97 Table.7: Plug and Cable Assemblies Matching plug and cable assemblies for the mini style receptacle options may be ordered as follows: XZCPL* Cable Description Cable Length Pins Matches Receptacle Option Catalog Number ft BH05 ft 5 57 BH05 Plug and cable ft BH05 ft BH09 ft 9 97 BH09 ft BH09.5 ft XZCPL Pre-wired connector, female.0 ft XCSDMR L / XCSDMP L XZCPL5.8 ft XZCPL0 a Direct opening contacts meet IEC requirements for positive opening contacts when using head. Building a Complete Switch Complete Switch = Body (with contact assembly) + Head + Lever Example: Body Head Lever ZCKJH7 + ZCKE05 + ZCKY = XCKJ05H7 Non-Plug-in Body ZCKJH7 Rotary Head ZCKE05 with Operating Lever ZCKY ZCKJ*D () = = = NC - = NO 5 = A / V max. 0 File CCN E98 NKCR File Class LR087-0 Acceptable Wire Sizes: AWG Recommended Terminal Clamp Torque: lb-in 0 Schneider Electric -7

28 Heavy Duty / Industrial Metal Body Table.8: Lever-Operated Heads Contact Operation with Switch Bodies: Standard operation Step CW and/or CCW Step -, - first step, - second step XCKJ Operating Heads Refer to Catalog 900CT007 Step Step Step Operating ZCKJa / J / J / JH7 ZCKJ / JH7 ZCKJ5H7 a Force/Torque (P) (P) Catalog Number oz-in, 0.5 N ZCKE05 ZCKE05 Programming CW and CCW CW CW and CCW CCW Maintained operation oz-in, 0.5 N ZCKE Note: Neutral position head ZCKE0 is not available separately. Order the head and body subassemblies from page -. Table.9: Plunger-Operated Heads Contact Operation with Switch Bodies: Step Step Step Operating ZCKJa / J / J / J / H7 ZCKJ / JH7 ZCKJ5H7 a Force/Torque Catalog Number Top rod plunger (P) " ".".08.(P) - 0.." 8 oz 8 N ZCKE Ball-bearing top plunger Steel roller plunger." "." 8 oz 8 N 8 oz 8 N ZCKE ZCKE7 One-way Delrin roller based on actuation by 0 cam One way steel roller based on actuation by 0 cam (P).05"..9(P) oz 8 N 8 oz 8 N ZCKE ZCKE Side rod plunger.0" ".05".. (P) oz 8 N ZCKE Side steel roller-plunger, horizontal based on actuation by 0 cam Side steel roller-plunger, vertical based on actuation by 0 cam (P)..07(P) oz 8 N 8 oz 8 N ZCKE ZCKE5 a Direct opening when used with any head on this page except ZCKE09 (maintained operation) Schneider Electric

29 Heavy Duty / Industrial Metal Body Table.50: Omnidirectional Heads Contact Operation with Switch Bodies: XCKJ Operating Heads, Replacement Parts, and Levers Refer to Catalog 900CT007 Step Step Step ZCKJ, J,J,J ZCKJ, J ZCKJ5 Operating Force/Torque Catalog Number Non-plug-in Style Contact Block XESP5 ZCKY// ZCKY/ ZCKY5/5/5/59 ZCKY Cat whisker-steela Wobble coil springsa a Flexible operators do not guarantee direct (positive) opening operation. Table.5: Operating Headsfor extended temperature ranges Description Low temperatureb -0 F to +8 F (-0 C to +70 C) Catalog Number 8. oz-in, 0. N 8. oz-in, 0. N ZCKE0 ZCKE08 High temperature b - F to +8 F (-5 C to + C) Lever operated Standard operations ZCKE05 ZCKE055 Maintained operations ZCKE09 ZCKE095 Top rod plunger ZCKE ZCKE Ball-bearing top plunger ZCKE ZCKE5 Top roller plunger ZCKE7 ZCKE75 Plunger operated One way Delrin roller ZCKE ZCKE5 One way steel roller ZCKE ZCKE5 Side rod plunger ZCKE ZCKE5 Side steel roller plunger-horizontal ZCKE ZCKE5 Side steel roller plunger-vertical ZCKE5 ZCKE55 Omnidirectional Cat whisker ZCKE0 ZCKE05 Wobble coil spring ZCKE08 ZCKE085 b The minimum temperatures listed are based on the absence of freezing moisture or water. Table.5: Replacement Parts Description (see page -7 for contact description) Direct Opening Catalog Number Contact block for ZCKJH7 Y XESP5 Contact block for ZCKJH7 N XESP0 Contact block for ZCKJH7 N XESP0 Contact block for ZCKJ5H7 Y XENP5 Contact block for ZCKJ8H7 (gold flashed) Y XESP58 Contact block for ZCKJ8H7 (gold flashed) N XESP08 Plug-in module for ZCKJH7 (includes contact block) N ZCKJ0H7 Plug-in module for ZCKJ (includes contact block) N ZCKJ0H7 Plug-in module for ZCKJ (includes contact block) N ZCKJ0H7 Base receptacle for ZCKJH7 ZCKJ09H7 Base receptacle for ZCKJH7 ZCKJ09H7 Base receptacle for ZCKJH7 ZCKJ09H7 ZCKY7 ZCKY8 ZCKY9 Table.5: Lever Arms Description Adjustment Increments Catalog Number Adjustable or Flexible Operators c Adjustable Delrin roller, 0.7 in. diameter, 0. in. wide, in. long (max.) 5 or 90 ZCKY Adjustable steel roller, 0.7 in. diameter, 0. in. wide, in. long (max.) 5 or 90 ZCKY Adjustable rod-square, steel, /8 in. side, 5. in. long (max.) 5 or 5 ZCKY5 Adjustable rod-round, fiberglass, /8 in. diameter, 5. in. long (max.) 5 or 5 ZCKY5 Adjustable rod-round, steel, /8 in. diameter, 5. in. long (max.) 5 or 5 ZCKY5 Adjustable rod-round, plastic, / in. diameter, 8. in. long (max.) 5 or 5 ZCKY59 Coil spring lever 5 or 90 ZCKY8 Spring rod lever 5 or 90 ZCKY9 Reverse Mounting Delrin roller 0.9 in. diameter, 0. in. wide,. in. long 5 or 5 d ZCKY Steel roller 0.9 in. diameter, 0. in. wide,. in. long 5 or 5 d ZCKY Ball bearing roller 0.9' diameter, 0. in. wide,. in. long 5 or 5 d ZCKY Fork, track, Delrin roller, 0.9 in.diameter, 0. in. wide for ZCK-E09 5 or 5 d ZCKY Fork, track, Delrin roller, 0.9 in. diameter, 0. in. wide for ZCK-E09 5 or 5 d ZCKY7 c Adjustable and flexible operators do not guarantee positive opening operation. d Reverse mounting: The higher increment (5 ) is a direct (positive) opening contact feature which ensures no loss of mechanical effort between the actuation point and the moving contact bridge of the direct (positive) contact (N.C.) even if the lever is loosely mounted. 0 Schneider Electric -9

30 Heavy Duty Industrial Metal Plug-in Body 9007C Adaptable Sub-Assemblies Class 9007 / Refer to Catalog 900CT H 9007 G 9007 K 9007 L 9007 R + mushroom button 9007 GD 9007 E 9007 ED 9007 J 9007 D 9007 F 9007 JKC 9007 KC 9007 CT CT 9007 CT CO CO 9007 CO5 NOTE: Order the mushroom operator cap from Table.5 on page Schneider Electric

31 Heavy Duty Industrial Metal Plug-in Body 9007C Adaptable Sub-Assemblies Class 9007 / Refer to Catalog 900CT MA 9007 HA 9007 FA 9007 EA 9007 FA 9007 LA AA 9007 LA 9007 KB 9007 CA 9007 A, B, C, N, T5, T BA 9007 KA 9007 HA 9007 RA 9007 HA NOTE: Head 9007C is for use with levers LA9 and LA. 0 Schneider Electric -

32 Heavy Duty Industrial Single- and Two-Pole 9007C Limit Switches Class 9007 / Refer to Catalog 900CT007 Oiltight, Watertight SwitchesStandard and Compact Bodies Table.5: All Type C Switches Rated NEMA P and UL Type P Select Turret Head Standard Pre-travel Spring Return CW & CCW a Low Differential Spring Return CW & CCW a Rotary Lever Arm Neutral Position Standard Pre-travel Spring Return CW & CCW Low Differential Spring Return CW & CCW Light Operating Torque Spring Return CW & CCW a Maintained Contact CW (Trip) CCW (Reset) Side Roller- Plunger Spring Return Vertical Roller b Type Side Plunger Side Push- Rod Plunger Spring Return Side Push- Rod Plunger Adjustablec Spring Return Side Push- Rod Plunger Maintained Contact Select Basic Switch Standard Box Plug-in Compact Box Plug-in UL Listed for Hazardous Location Division I Class I Groups B, C, D Class II Groups E, F, G Contacts Type Type Type Type Type Type Type Type Type Type N.O. N.C. N.O. N.C. N.O. N.C. Neutral Position N.O. N.C. Two Stage N.O. N.C. N.O. N.C. N.O. N.C. N.O. N.C. Neutral Position N.O. N.C. Two Stage C5B C5A C5N C5C C5F C5G C5GD C5H CB CA CN CC CF CG CGD CH C8T0 C8T5 CB CA CN CF CG CGD C5B C5A C5N C5C C5F C5G C5GD C5H CR5B CR5A CR5N CR5C CR5F CR5G CR5GD CR5H CRB CRA CRN CRC CRF CRG CRGD CRH CR7T0 CR7T5 CR5B CR5A CR5N CR5F CR5G CR5GD Head Only (Example: 9007B) B A T0 T5 N C F G GD H Pre-travel in. ( mm) 0. in. (. mm) Nominal Operating Data Pretravel Two Stage Plug-in Replacement Units First Stage First to Second Stage in. ( mm) -/ -/ -/ 0.0 in. (0.5 mm) Total Travel in. (. mm) 0.5 in. (. mm) Differential 0.0 in. (0.8 mm) Reverse Overtravel Operating Torque/Force Pole & Pole Repeat Accuracy Linear travel of cam (-/ in. lever arm) Acceptable Wire Sizes: AWG Recommended Terminal Clamp Torque: 7 lb-in (0.80 N m) lb-in (0.5 N m) ± 0.00 in. (0.05 mm) lb-in (0.5 N m) ± 0.00 in. (0.0 mm) lb-in (0.5 N m) ± 0.00 in. (0.05 mm) lb-in (0.5 N m) ± 0.00 in. (0.05 mm) 5 oz-in (0.8 N m) ± 0.00 in. (0.05 mm) lb-in (0. N m) ± 0.00 in. (0.05 mm) lb (0.5 N m) 7 lb (0.80 N m) 0.00 in. (0. mm) To order the basic switch and head without the plug-in receptacle base, substitute the letters CO for the first C in the type number. Example: Open type replacement for Type C5B is Type CO5B. a These devices are factory set to operate the contacts in both the CW and CCW directions. Mode of operation is field convertible to CW only or CCW only. To order factory converted devicesfor CCW only operation, change the at the end of the type number to (Example: C5B becomes C5B); for CW only operation, delete the at the end of the type number (Example: C5B becomes C5B). b Can be converted to horizontal roller type in the field. To order horizontal roller version add the letter H at the end of the equivalent vertical roller version type number (Example: C5F would become C5FH). c To lock the nut in the desired position, crimp the slot near the bottom of the nut. Selection Mode Arrow CW/CCW Mode ChangeLever Arm Type Mode of operation is easily convertible to clockwise, counterclockwise, or both. Simply point the arrow to the letters representing the desired directioncw, CCW, or CW/CCW. All parts are captive. CW C W/ W CC CCW Exploded view page -0 Lever arms page -, -5 Electrical ratings page -5 Special features page -5, Schneider Electric

33 Heavy Duty Industrial Single- and Two-Pole Table.55: All Type C Switches Rated NEMA P And UL Type P 9007C Limit Switches Class 9007 / Refer to Catalog 900CT007 Select Turret Head Top Plunger Wobble Stick Plug-In Select Basic Switch Standard Box Plug-in Compact Box Plug-in UL Listed for Hazardous Location Division I Class I Groups B, C, D Class II Groups E, F, G Top Roller- Plunger Spring Return Top Push- Rod Plunger Spring Return Top Push-Rod Plunger Adjustable b Spring Return Palm Operated a Wobble Stick Universal d Delrin c Extension d Wobble Stick Wire Extension d Wobble Stick Coil Spring Extension d Cat Whisker Plug-in Unit without Head Plug-in Receptacle Only Contacts Type Type Type Type Type Type Type Type Type Type Type N.O. N.C. N.O. N.C. N.O. N.C. Neutral Position N.O. N.C. Two Stage N.O. N.C. N.O. N.C. N.O. N.C. N.O. N.C. Neutral Position N.O. N.C. Two Stage C5D C5E C5ED C5Ra C5JKC C5J C5K C5KC C5L CO5 CT5 CD CE CED CRa CJKC CJ CK CKC CL CO CT CO8 CT CD CE CED CRa CJKC CJ CK CKC CL CO CT C5D C5E C5ED C5Ra C5JKC C5J C5K C5KC C5L CO5 CT5 CR5D CR5E CR5ED CR5Ra CR5JKC CR5J CR5K CR5KC CR5L CRD CRE CRED CRRa CRJKC CRJ CRK CRKC CRL CR5D CR5E CR5ED CR5Ra CR5JKC CR5J CR5K CR5KC CR5L Head Only D E ED R a JKC J K KC L Pre-travel 0.08 in. ( mm) 0 (Any Direction) 0 Nominal Operating Data Pretravel Two Stage Plug-in Replacement Units First Stage First to Second Stage 0.08 in. ( mm) 0 (Any Direction) in. (0.0 mm) 5 Total Travel 0.5 in. (. mm) Differential 0.0 in. (0.5 mm) Reverse Overtravel Operating Torque/ Force Pole and Pole Repeat Accuracy Linear travel of cam Acceptable Wire Sizes: AWG Recommended Terminal Clamp Torque: 7 lb-in (0.80 N m) lbs. (0. N m) lb-in (0. N m) 7 oz-in (0.05 N m) ± 0.00 in. (0.0 mm) To order the basic switch and head without the plug-in receptacle base, substitute the letters CO for the first C in the Type number. Example: Open type replacement for Type C5D is Type CO5D. a Mushroom button must be ordered separately. See Table.5. b To lock the nut in the desired position, crimp the slot near the bottom of the nut. c Delrin is a registered trademark of DuPont. Not for use outdoors. d Wobble stick extensions are available separately for the universal head or as replacements for complete devices. See Table.57. Table.5: Mushroom Button For Palm Operated Turret Head Color -/8 in. Dia. Button Type No. -/ in. Dia. Button Type No. Black 58CG 58CG Red 58CG 58CG Green 58CG 58CG Yellow 58CG8 58CG8 Table.57: Wobble Stick Extensions Description Delrin extension Wire extension Coil spring extension Catalog Number 9007WJ 9007WK 9007WKC Type C File CCN E59 NKCR File Class LR590-0 Type CR File CCN E005 NOIV File Class LR Compact Body Hazardous Location Standard Body 0 Schneider Electric -

34 Heavy Duty Industrial Single- and Two-Pole 9007AW and 9007C Lever Arms Class 9007 / Refer to Catalog 900CT007 Lever Arms for 9007AW and 9007C Heavy Duty / Industrial Limit Switches Standard roller is hardened oil-impregnated sintered iron. Bold-face Type numbers indicate the most commonly used lever arms. Table.58: Cast Zinc Lever Arms Roller a Cast Lever Arm Length of Arm (A) 7/8" -/8" -/" " -/" " Length of Arm (A) 7/8" -/8" -/" " -/" " Standard /" Dia. (B) /" Wide (C) Standard /" Dia. (B) 5/8" Wide (C) Standard 5/8" Dia. (B) /" Wide (C) Standard 5/8" Dia. (B) 5/8" Wide (C) Nylon /" Dia. (B) /" Wide (C) Nylon 5/8" Dia. (B) /" Wide (C) Nylon 5/8" Dia. (B) 5/8" Wide (C) 90 Forked Rod -/" Spring Rods, Steel LA9 Dimensions page -5 For more information on LA9, refer to catalog 900CT007. Nylon a " Dia. (B) 5/8" Wide (C) Type Type Type Type Type Type Type Type BA MA CA DA EA Nylon " Dia. (B) /" Wide (C) BA MA CA DA EA Ball Bearing /" Dia. (B) /" Wide (C) AA BA MA CA DA EA Standard /" Dia. (B) /" Wide (C) Roller on Opposite Side to Standard AA BA MA CA DA EA Standard 5/8" Dia. (B) /" Wide (C) Roller on Opposite Side to Standard BA8 MA8 CA8 DA8 EA8 Standard 5/8" Dia. (B) 5/8" Wide (C) Roller on Opposite Side to Standard AA8 BA8 MA8 CA8 DA8 EA8 Without Roller AA7 BA7 MA7 CA7 DA7 EA7 Standard /" Dia. (B) /" Wide (C) (Countersunk Roller Pin) BA MA CA DA EA Cable Operated With Eyebolt (/8" I.D.) Instead of Roller Type Type Type Type Type Type Type Type BA MA CA DA EA AA9 BA9 MA9 CA9 DA9 EA9 BA MA CA DA EA AA5 BA5 MA5 CA5 DA5 EA5 AA BA MA CA DA EA AA0 BA0 MA0 CA0 DA0 EA0 MA CA DA Recommended in place of Types BA7, CA7, DA7, EA7 and MA7 lever arms with steel rollers. If necessary, the latter arms can be furnished at an additional cost. Table.59: Flat Steel Lever Arms Flat Steel Lever Arm Length of Arm (A) 7/8" -/8" -/" " -/" " Standard Roller 5/8" Dia. (B) /" Wide (C) Standard Roller 5/8" Dia. (B) 5/8" Wide (C) Nylon Roller /" Dia. (B) /" Wide (C) Nylon Roller " Dia. (B) /" Wide (C) No Roller Type Type Type Type Type AAS BAS CAS DAS EAS AAS BAS CAS DAS EAS Table.0: 90 Forked Cast Zinc Lever Arms Roller Position Rollers on Same Side Standard Rollers /" Dia. (B) /" Wide (C) Standard) Rollers 5/8" Dia. (B) /" Wide (C MA8S Nylon Rollers /" Dia. (B) /" Wide (C) BAS CAS DAS EAS Nylon Rollers /" Dia. (B) " Wide (C) R.H. Roller on Opposite Side LA5 LA LA7 LA LA8 90 Forked Arm L.H. Roller on -/" Length Opposite Side LA LA LA8 LA LA9 Approximate shipping weights range from /8 to / lb. Table.: One-Way Cast Zinc Roller Lever Arm One-Way Roller Lever Arm -/8" -/" " -/" " Length of Arm Table.: One-Way Lever Arms One-Way Lever Arm Length of Arm AA0S BA0S CA0S DA0S EA0S Ball Bearing Rollers /" Dia. (B) /" Wide (C) Type Type Type Type Type LA LA LA LA0 LA7 Roller, -/" Dia. (B) /" Wide (C) Cast Arm Flat Steel Arm Type Type BA MA CA DA EA BAS CAS DAS EAS Roller Standard /" Dia. (B) /" Wide (C) Nylon /" Dia. (B) /" Wide (C) Ball Bearing -/" Dia. (B) /" Wide (C) Rod Type Type Type Type Type -/" RA RA8 RA9 5" FA in. mm D 0..9 Table.: Offset-style Cast Zinc Lever Arms b A MA Cast Zinc Lever Arm Dimensions A = Length of Lever Arm B = Roller Diameter C = Roller Width D = C + 5/" B C See the tables on this page for A, B, and C dimensions. Offset Lever Arm Dia. (B) Width (C) Type Roller inside. " Length 7/" Offset -/" Length 7/8" Offset Table.: Rod Type Lever Arms Rod, in. (mm) 0 (5) Stainless Steel Rod (0) Spring Rod, Steel 8 (0) Spring Rod, Steel Spring Rod, Delrin Looped Delrin Rod Standard Roller 5/8 5/8 / / / 5/8 / 5/8 KA KA KA KA Ball Bearing / / KA9 Nylon / / / / / KA8 KA Standard Roller / / Type FA FA FA FA5 FA KB KB b - 0 Schneider Electric

35 Heavy Duty Industrial Single- and Two-Pole Lever Arms Standard roller is hardened oil-impregnated sintered iron. Bold-face type numbers indicate the most commonly used lever arms. Table.5: Adjustable Length Lever Arms Description Without Roller Standard 5/8" Dia. /" Wide Lever Arm, Length Adjustable from 7/8" to " Standard 5/8" Dia. 5/8" Wide Nylon 5/8" Dia. /" Wide Type Type Type Type Type Type Type Type Type Non-bendable HA0 HA HA HA HA HA Bendable HA9 HA5 HA HA8 HA5 HA HA0 HA HA a Recommended in place of Types HA and HA7 lever arms with steel rollers. If necessary these arms can be furnished at an additional cost. Table.: 0 Angular Adjustable Lever Arms 7/8" -/8" -/" " -/" " Note: Length of Arm Standard 5/8" Dia. /" Wide Standard /" Dia. /" Wide Roller Ball Brg. /" Dia. /" Wide Nylon 5/8" Dia. /" Wide Nylon a " Dia. 5/8" Wide Nylon /" Dia. /" Wide 9007AW and 9007C Lever Arms and Special Features Class 9007 / Refer to Catalog 900CT007 Delrin -5/8" Dia. /" Wide Ball Bearing /" Dia. /" Wide Roller Outside Roller Inside Roller Outside Roller Outside Type Type Type Type Type Type AAM BAM MAM CAM DAM EAM AA5M BA5M MA5M CA5M DA5M EA5M AAM BAM MAM CAM DAM EAM AA8M BA8M MA8M CA8M DA8M EA8M AA8M BA8M MA8M CA8M DA8M EA8M Roller can be changed in the field from roller outside to roller inside position or vice versa. Approximate shipping weights range from /8 to / lb. AA9M BA9M MA9M CA9M DA9M EA9M Nylon " Dia. /" Wide Rubber Tire -/8" Dia. /" Wide E A C B F A D A = Length of Lever Arm B = Roller Diameter C = Roller Width B C Special Features Table.7: Special Features (do not apply to Type CR unless noted)field Installable Description Conduit Seal Only Conduit seal fits in conduit entrance and excludes liquids Adapters Switch with adapter plate permitting substitution of any Type C switch with standard box for any Type T switch with Style B baseplate Adapter plate kit only (plate plus mounting screws) for above Adapter plate to allow direct substitution of Type C plunger switches for Type B plug-in plunger switches use only if there is a problem in lining up cam tracks Adapter plate kit permitting direct substitution of any Type C lever arm switch with standard box for ANY Type AW lever arm switch Metric conduit-connection adaptermale /" NPT on one end, female 0 mm on the other end b c Dimensions: 0. x.9 x in. Dimensions: 0. x.07 x in. 5 hole seal 9 hole seal Standard Box Compact Box Part Number Form Y7 Class 9007 Type BT Class 9007 Type CT0 b Type CT c Class 9007 Type CT Class 9007 Type CT Rotary lever arms Rod type lever arms 9007C A, B, C, N, T5, T0 9007FA 9007FA Dual dimensions: () () in. mm Ø 0.. x 0.0/5 x 0./ HLS.. x 0- Tapped HLS Back Mtg 0.9/7 DP.. / NPT. () (max) Ø Schneider Electric -5

36 Heavy Duty Industrial Single- and Two-Pole 9007C Factory Modifications (Forms) Class 9007 / Refer to Catalog 900CT007 Table.8: Special Features (do not apply to Type CR unless noted)not Field Installable, Except Where Noted Special Features Optional Shaft Equipped With 9007T / 9007FT Hub: Any lever arm Type C, CF or CR switch can be furnished with an optional shaft and hub combination which will accept the lever arms normally used with Type T and FT limit (position) switches. To order, add S9 as suffix to the device type number. For example, to order a 9007 C5B with this modification, order as a 9007 C5B-S9. For details about the switches and lever arms that can be furnished with this modification, see catalog 9007CT007. Hub Only: Can be field installed on any Type C lever type switch. LED Pilot Light, - Volts AC or DC on Plug-In Type Switch (Type C5, C5, C, C, C, or C8): Addition of LED pilot light in parallel with N.O. contact (light normally on) Form P5 Thru P9 Form P0 L L Addition of LED pilot light in parallel with N.C. contact (light normally off) L B A Light Normally On Light Normally Off Pre-Wired Receptacle CR CR L *Customer Installed Jumper CR CR *Only one of the jumpers may be used Pilot Light is ON when load is energized Addition of two LED pilot lights, one in parallel with N.O. contact (light normally on), one in parallel with N.C. contact (light normally off) Addition of two LED pilot lights in parallel with N.O. contacts (lights normally on) (Types C, C, C or C8 only) Addition of two LED pilot lights in parallel with N.C. contacts (lights normally off) (Types C, C, C, or C8 only) Addition of one isolated LED pilot light (light on when load is energized) (Type C5 only. Not available with Y90.) Plug-in limit (position) switch furnished with pre-wired mini 5 pin male receptacle. For use with Brad Harrison female portable plug No. 0, 07, or 08 (or equal). (Not available with P0 or for hazardous locations.) Form Add S9 as a suffix to the catalog number Single Pole Same as Y90 but with different wire color coding Y905 Tamperproof ScrewsComplete Switch Only Same as Y90 but with tamperproof screws on head and body Y90 Other versions with different wiring diagrams per automotive requirements are available. Contact your local Schneider Electric field office. Cat. No. 9007S9 P5 P P7 P8 P9 P0 Y90 Wiring Diagrams Form Y90 Forms Y90 and Y90 Form Y905 Mating plug and cables available. Green- Orange- -Red White- -Black White- -Black Orange- -Red Green- Potted Limit (Position) Switch Or Plug-In Receptacle Only: With Individual Wires Single pole plug-in limit (position) switch or receptacle pre-wired with five # wires 5 ft long and wire entry completely sealed with epoxy resin Double pole plug-in limit (position) switch or receptacle pre-wired with nine # wires 5 ft long and wire entry completely sealed with epoxy resin With STOWA Cord Single pole plug-in limit (position) switch or receptacle pre-wired with five conductor # STOWA cord 8 ft long and wire entry completely sealed with epoxy resin Same as Y85 but with different wire color coding Double pole plug-in limit (position) switch or receptacle pre-wired with nine conductor # STOWA cord 8 ft long and wire entry completely sealed with epoxy resin Same as Y85 but with different wire color coding Tamperproof ScrewsComplete Switch Only With Individual Wires Same as Y8 but with tamperproof screws on head and body Same as Y8 but with tamperproof screws on head and body With STOWA Cord Same as Y85 but with tamperproof screws on head and body Same as Y85 but with tamperproof screws on head and body Same as Y855 but with tamperproof screws on head and body Same as Y85 but with tamperproof screws on head and body Other versions with different wiring diagrams for automotive requirements are available. Y8 Y8 Y85 Y855 Y85 Y85 Y8 Y8 Y85 Y85 Y857 Y858 Forms Y85 and Y85 Forms Y85 and Y85 Forms Y855 and Y857 Forms Y85 and Y858 -Orange -Black Red- White- Orange- 8 Red- 7 -Brown -Yellow White- Orange- -Black -Red Yellow- 8 Brown- 7 -Black -White Green- Black- -Blue Green- Red- -Blue White- 5 -Pink Green- Orange- 5 -Pink Green- Low TemperatureLever Types Only: Limit (Position) switch will operate in an ambient temperature range of -0 to +85 F (standard limit switch ambient temperature range is -0 to +85 F). Minimum temperature is based on the absence of freezing moisture or water. Fluorocarbon Rubber (FKM) Gaskets And Seals Substitute fluorocarbon rubber gaskets and seals on: Lever arm type, standard box (shaft seals on lever arm types are fluorocarbon rubber as standard) Lever arm type, compact box (shaft seals on lever arm types are fluorocarbon rubber as standard) Plunger type, standard box Plunger type, compact box Substitute fluorocarbon rubber boot only on plunger type switches Note: Fluorocarbon rubber has been shown to resist sunlight aging problems. Direct Acting Contacts Substitution of direct acting contact unit for snap switch of single-pole switch: One pole, normally closed, slow-make slow-break, direct acting contact mechanism substituted for standard snap switch on Types C5, C5, CF5, and CR5 devices. This mechanism was designed for use in emergency overtravel applications. The movable contact of this basic switch unit is acted upon directly by the actuating mechanism of the limit switchit does not depend on the force exerted by a snap-switch blade or a spring to open the circuit. Because these contacts are slow-make slow-break, they are best suited for applications where they are not actuated during normal operation, but only if abnormal overtravel is encountered. d The direct acting contacts described above come standard on the 9007CLS hoist overtravel switch. Direct Acting Contact Mechanism (shown without cover) Y8 Y0 Y0 Y0 Y0 Y0 Y - 0 Schneider Electric

37 Severe Duty, Oiltight, Mill and Foundry 9007T, 9007FT Class 9007 / Refer to Catalog 900CT007 Table.9: Select the Operating Sequence Select the Basic Switch Surface Mounting Complete with Base Plate, Without Lever Arm (bold type numbers indicate the most commonly used switches) Base Plate A B C D Universal Type No. No. No. d No. No. 5 No. No. 7d Single-Pole Double-Throw Spring-Return CW Only Initial Position and CCW CW Single-Pole Double-Throw Spring-Return CW Only Single-Pole Double-Throw Maintained Contact Single-Pole Double-Throw Spring-Return Neutral Position Initial Position Single-Pole Double-Throw Spring-Return CCW Only Initial Position and CW Single-Pole Double-Throw Spring-Return CCW Only Single-Pole Double-Throw Maintained Type Type Type Type Type Type Type TUA TUB TUC TUD Initial Position and CCW Initial Position and CCW A B Intermediate Final Pos. CW Pos. CW TUA TUB TUC TUD Spring return of arm to initial position, contact position maintained until operated in reverse direction CCW CW If high speed cam or snap-back is present use No. TUA TUB TUC TUD Pre-travel Int. Pos. 9, Final 7 Int. Pos. 9, Final 0 Nominal Total-travel Operating Differential Data Oper. Torque lb-in lb-in lb-in lb-in lb-in lb-in.5 lb-in Repeat Accuracy b ±0.00 in. ±0.00 in. ±0.00 in. ±0.00 in. ±0.00 in. ±0.00 in. ±0.00 in. To convert sequences, remove the base plate, positioning plate and latches. Reassemble c B B the positioning plate and latches as shown. A A CCW TUA TUB TUC TUD CW CCW TUA5 TUB5 TUC5 TUD5 Initial Position and CW Intermediate Position CCW TUA TUB TUC TUD Final Position CCW If high speed cam or snapback is present use No. CW TUA7 TUB7 TUC7 TUD7 Select Operating Sequence Universal Type Standard Type No. 8d No. 9 No. 0 No. No. No. No. No. Single-Pole Maintained Double-Throw Neutral Position Initial Position If high speed cam or snap-back is present use No. Single-Pole Double-Throw Spring-Return Slow Make Slow Break Initial Position and CCW Single-Pole Double-Throw Spring-Return Slow Make Slow Break Initial Position Single-Pole Double-Throw Spring-Return Slow Make Slow Break Initial Position and CW Single-Pole Double-Throw Maintained CCW Single-Pole Double-Throw Spring-Return CW & CCW Initial Position Single-Pole Double-Throw Spring-Return CW & CCW Initial Position Single-Pole Double-Throw Spring-Return CW & CCW Slow Make Slow Break Initial Position Select Basic Switch CCW CW CW CCW CW CCW CW CCW & CW CW & CCW Intermediate Final Position Position CW & CCW Surface Mounting Base Plate A B C D Type Type Type Type Type Type Type Type TUA8 TUB8 TUC8 TUD8 TUA9 TUB9 TUC9 TUD9 TUA0 TUB0 TUC0 TUD0 TUA TUB TUC TUD TUA TUB TUC TUD Pre-travel 5 Int. Pos. 9, Final 9 Nominal Total-travel Operating Differential Int. Pos. 5.5, Final Data Oper. Torque.5 lb-in lb-in lb-in lb-in 8 lb-in 0 lb-in 0 lb-in 0 lb-in Repeat Accuracy b ±0.00 in. ±0.00 in. ±0.00 in. ±0.00 in. ±0.00 in. ±0.00 in. ±0.00 in. ±0.00 in. To convert sequences, remove the base plate, positioning plate and latches. Reassemble c A B Not Adjustable A A A the positioning plate and latches as shown. a Pre-travel listed may vary up to 5 additional for universal switches or up to additional for standard switches due to the free travel of the lever arm at the initial position. b Linear travel of cam on -/ in. lever arm. c Remove the spring from the positioning plate. d Sequence, 7, and 8 devices are available but are not recommended where high speed cams or lever arm snap-back is present. The application should be checked and No. sequence substituted where possible. Note: To obtain a Type FT Foundry Switch, change the T at the beginning of the equivalent Type number to FT (for example, TUB changes to FTUB). TSA TSB TSC TSD TSA TSB TSC TSD TSA TSB TSC TSD Lever arms page -8 0 Schneider Electric -7

38 Severe Duty, Oiltight Mill and Foundry 9007TUB 9007T, 9007FT Class 9007 / Refer to Catalog 900CT007 Class 9007 Type T and FT, Oiltight Table.70: Lever Arms for Types T and FT Limit Switches or Type C with S9 Hub Type of Arm Straight Offset Forked 90 Forked Cable Operated Rod Length of Arm (in.) Roller Position Description Roller Width Type Roller Dia. (in.) / -/8 -/ Front or Back / B B B -/ Front or Back / B B B -/ Front or Back / B7 B8 B9 -/ Front or Back / B B B -7/8 None None Without Roller B 5 Front or Back / B9 Adj. Does not include a lever arm clamp or rod. Lever arm clamp is requireduse 9007 R or R7, plus a customer-supplied rod. / R8 R9 R0 -/ Inside Offset / C C C Outside Offset / D D D -7/8 Outside Offset / E E5 E Inside Offset / F F5 F -/ Rollers on Same Side / J J -/ LH Roller on Opposite Side / K K -/ RH Roller on Opposite Side / N N -/ Rollers on Same Side / X X -/ RH Roller on Opposite Side / Y Y -/ LH Roller on Opposite Side / Z Z -/ None None Y -/ With eyebolt (/ in. I.D.) instead of roller None B7 Adj. Clamp for / in. Rod (rod not included) None R Adj. Clamp for / in. Key Stock (key stock not included) None R7 Weld-On -/ None None G0 -Way Roller -/ Outside Offset / D Conveyor -/ in. dia. -/ in. Delrin roller. For use with Type T and FT only. R Side Guide 8-7/ 7/8 in. dia. -/ in. Delrin roller. For use with Type T, FT, or C with S9. R 9007FTUB Table.7: Separate Base Plates Style Mounting Holes Part Number A Nonea 9DG B End 9DG C Side 9DG D End 9DG a No mounting holes in base plate. Side mounting holes in switch case must be used. For all Type T and FT: Acceptable Wire Sizes: 8 AWG Recommended Terminal Clamp Torque: lb-in /" NPT Style aseplate Shown Center of Shaft Center of Shaft Mtg. Holes.57 Dia Center of Shaft.5 57 Style B Style C Style D File 59 CCN NKCR File LR590 Class Schneider Electric

39 Severe Duty, Oiltight Mill and Foundry R.B.Denison Lox-Switch L L00/00 Refer to Catalog 900CT007 Table.7: General Specifications Temperature range 0 to +00 F (-7 to +9 C) standard. For high and low temperature options, see Table.79 on page -0. Minimum temperatures are based on the absence of freezing moisture or water. Enclosure rating NEMA,, and ; IP 5, Vibration resistance 0G max. (0 55Hz) Repeatability.0 Cable entry /" NPT standard double circuit, /" NPT triple circuit Contact Characteristics Rated thermal current 0 A Rated insulation voltage 00 Vac and Vdc Wire (max.) x AWG or x AWG per screw terminal Table.7: Switching Ratings: A00 (AC), P00 (DC) Contact Rating Designation Maximum current (A) V V 0 V 50 V 80 V < 00 V Maximum VA L00WSM (M=Make, B=Break) M B M B M B M B M B M B M B A00 (AC) P00 (DC) Table.7: Type L Selection Other selections are available. Refer to catalog 900CT007. Mounting Plates, L00 and L00 Models Style Description Contact Diagram Operating Torque Cat. No. Snap-action CW Spring return 90 oz-in (. N m) 90 oz-in (. N m) L00WSM L00WSM Snap-action CCW Spring return 90 oz-in (. N m) 90 oz-in (. N m) L00WSM L00WSM Style Maintained contact a CW and CCW Snap action 5 oz-in (0. N m) 5 oz-in (0. N m) L00WSM L00WSM Snap action CW Spring return oz-in (. N m) 90 oz-in (. N m) L00WDRM L00WDRM Style Neutral position a N.O.-CW, N.O.-CCW Spring return Snap action Neutral position a N.O.-CW, N.O.-CCW Maintained in CW only 70 oz-in (. N m) 70 oz-in (. N m) 70 oz-in (. N m) 70 oz-in (. N m) L00WNSM L00WNSM L00WNSLM9 L00WNSLM9 Step Sequence CW Spring return, Snap action, N.O oz-in (.0 N m) L55WDRM5 Style Step Sequence CCW Spring return, Snap action, N.O oz-in (.0 N m) L55WDLM57 Step Sequence CW Spring return, Snap action, N.C oz-in (.0 N m) L55WDLM58 Step Sequence CCW Spring return, Snap action, N.C oz-in (.0 N m) L55WDRM59 Step Sequence CW Spring return Snap action N.O./N.C 0 oz-in (.0 N m) L00WS0SM0 a The lever must not be allowed to snap freely from any overtravel position. 0 Schneider Electric -9

40 Severe Duty, Oiltight Mill and Foundry L Style A L00/00 Refer to Catalog 900CT007 Interpreting the Catalog Numbers Use the table below to interpret the catalog numbers of the L00/L00 switches. Do not generate new catalog numbers from the table. If the required contact sequence is not listed, contact your local field office. The only modifications to the existing catalog numbers are: Mounting PlatesStyle,, or Front CoversMetal, transparent plastic, or transparent plastic with a neon light. Special FeaturesSelect from catalog 900CT007 and add to the type number. Style Housing Function Mounting Plate Front Cover Contact Arrangement L 0 0 W S P F Standard (mill) Extra heavy duty (foundry) Two circuit single operation Two circuit dual operation WS M Standard metal See catalog 900CT007 WD PF Transparent plastic Triple circuit WT GF Neutral WN Transparent plastic with neon light Rolling Pin.0 0 Adjustable Roller.9.8 Table.75: Steel Roller Lever Arms (0.5 in. wide, 0.75 in. dia.) Table.7: Lever Arm Options Length (L) in. mm Lever Number Description Suffix 0 (8.) AA in. diameter roller.00 (50.8) AH -/ in. diameter roller.50 (.5) AO -/ in. diameter roller.75 (9.8) AK Nylon roller N.00 (7.) AB Ball bearing roller (/ in. diameter) R.00 (0.) AM Stainless steel roller pin nylon roller NS.00 (.) AR Ex: AB; ABR Table.77: Rolling Pin For use with step switches for conveyor or belt applications Table.78: Roller, Adjustable from to in. (0.5 in. wide, 0.75 in. diameter) Length (L), In. (mm) Lever Number Length (L), In. (mm) Lever Number.5 (75.) AL0 Adjustable AL80.5 (75.) (Teflon for high temperature applications) AL0 to (50.8 to 0.) (50.8) AL80 Ministyle male receptacle Straight male receptacle Table.79: Housing options a Description Examples Prefix Adder or Modifier /" conduit opening: Available on circuit switches. Standard on circuit switches. L00WSM changes to GL00WSM G High temperature 0 to +50 F d Metal front cover only L00WSM changes to HL00WSM H Low temperature -0 to +00 F d L00WSM changes to TL00WSM T High shock. Available only on operating sequences,,, 5, 7-,,. L00WSM changes to L5WSM L00WSM changes to LWSM 5/ Gold contacts L00WSM changes to L5WSM L00WSM changes to LWSM 5/ Table.80: Wiring Description Examples Prefix Adder or Modifier Straight male receptacle pin b Factory prewired L00WSM changes to PL00WSM P 90 Angle male receptacle pin b Factory prewiredfacing right L00WSM changes to APL00WSM AP Ministyle male receptacle c 8 A max., 5 pin (double circuit) 7 A max., 7 pin (triple circuit) L00WSM changes to BL00WSM B B Potted and prewired 5 wires, ft long 5 wires, ft long 5 wires 8 ft long L00WSM changes to L00WSMP L00WSM changes to L00WSMP L00WSM changes to L00WSMP8 P P P8 Table.8: Accessories Table.8: Front covers Description Catalog Number Description Designator Sealed female plug and cable for P and AP receptacles Standard metal M ft 0000 pins, AWG STO cable, 0 C ft 0000 Transparent plastic cover with metal frame PF 0 ft Sealed female plug and cable for ministyle receptacle (B) Transparent plastic cover with metal frame and Neon indicator light (not connected) ft cable BH05 GF 5 pins, AWG STO cable, 05 C ft cable BH05 Example: L00WSM changes to L00WSPF ft cable BH05 a b c d Other options availablecontact your Schneider Electric representative for details. Receptacle is a pin male APL/PL-SWTS, Cannon part # MS0E0-P-F79 or equal. Ministyle male receptacles are: 5-pin, Brad Harrison #0 (or equal); 7-pin, Brad Harrison #805 (or equal) The minimum temperatures listed are based on the absence of freezing moisture or water. 90 angle male receptacle -0 0 Schneider Electric

OsiSense. XC Basic Limit Switches XCMN, XCKN, XCNT

OsiSense. XC Basic Limit Switches XCMN, XCKN, XCNT OsiSense XC Basic Limit Switches XCMN, XCKN, XCNT Courtesy of Steven Engineering, Inc. - () - - sales@steveneng.com - www.stevenengineering.com Courtesy of Steven Engineering, Inc. - () - - sales@steveneng.com

More information

Limit switches. 7 Page 71. Presentation. OsiSense XC Basic Compact design, plastic, with reset knob, types XCNR and XCNTR. b XCNR.

Limit switches. 7 Page 71. Presentation. OsiSense XC Basic Compact design, plastic, with reset knob, types XCNR and XCNTR. b XCNR. Presentation Compact design, plastic, with reset knob, types XCNR and XCNTR b XCNR with cable entry v With head for linear movement (plunger) Page v With head for rotary movement (lever) Page b XCNTR with

More information

Limit switches 3. Page 92. Page 92

Limit switches 3. Page 92. Page 92 Presentation, general characteristics b XCKS with cable entry v With head for linear movement (plunger) Page v With head for rotary movement (lever) Page Environment characteristics Conformity to standards

More information

Limit switches. Steel roller plunger. Metal end plunger with elastomer boot 4.6(P) mm

Limit switches. Steel roller plunger. Metal end plunger with elastomer boot 4.6(P) mm characteristics Complete switches with cable entry Type of head Plunger (fixing by the body) Form B () Form C () Form E () with elastomer boot Steel roller References of complete switches with ISO M x

More information

Double insulated, types XCK-P and XCK-T. With head for linear movement (plunger) operators

Double insulated, types XCK-P and XCK-T. With head for linear movement (plunger) operators Double insulated, types XCK-P and XCK-T Presentation XCK-P with 1 cable entry, conforming to CENELEC EN 57 With head for linear movement (plunger) operators Page 18 With head for rotary movement (lever)

More information

Limit switches. 6 Thermoplastic roller lever 1 direction of actuation SEN TRONIC AG. Presentation

Limit switches. 6 Thermoplastic roller lever 1 direction of actuation SEN TRONIC AG. Presentation Presentation Variable composition Spring-rod lever with thermoplastic end () Spring-rod lever, metal () Variable length thermoplastic roller lever () Round rod lever, thermoplastic, Ø mm L = mm () ZCK

More information

Safety Limit Switch

Safety Limit Switch Safety Limit Switch D4B-@N CSM_D4B-_N_DS_E_5_1 Snap-action contact with certified direct operation certification. Maintenance, seal, and resistance to shock increased and direct mechanism added. Three-conduit

More information

XCKP2145P16 limit switch XCKP - th.plastic roller lever var.length - 1NC+1NO - snap - M16

XCKP2145P16 limit switch XCKP - th.plastic roller lever var.length - 1NC+1NO - snap - M16 Characteristics limit switch XCKP - th.plastic roller lever var.length - 1NC+1NO - snap - M16 Product availability : Non-Stock - Not normally stocked in distribution facility Price* : 47.90 USD Main Range

More information

LK Position Switches TECHNICAL DATASHEET.

LK Position Switches TECHNICAL DATASHEET. LK Position Switches Technopolymer housing, one conduit entry Protection degree IP6 according to EN 60529 contact blocks available 46 actuators available Versions with stainless steel external parts Versions

More information

Compact plastic limit switches with positive opening mechanism

Compact plastic limit switches with positive opening mechanism Compact limit switches with positive opening mechanism LJK-N Series Positive opening mechanism Positive opening mechanism meets standards worldwide. A wide variety of actuators is available. The LJK-N

More information

Compact plastic limit switches with positive opening mechanism

Compact plastic limit switches with positive opening mechanism Compact limit switches with positive opening mechanism LJK-NSeries Positive opening mechanism Positive opening mechanism meets standards worldwide. A wide variety of actuators is available. The LJK-N conforms

More information

Position switches FR series

Position switches FR series Position switches FR series Selection diagram 01 A1 08 14 01-7 0 A 05 A5 external rubber gasket external rubber gasket for electrical panels external rubber gasket external rubber gasket 0 1 5 34 50 33

More information

D4B- N. Safety Interlock Switches. Safety Limit Switch. Specifications. Standards and EC Directives. Certified Standard Ratings D4BN

D4B- N. Safety Interlock Switches. Safety Limit Switch. Specifications. Standards and EC Directives. Certified Standard Ratings D4BN Safety Interlock Switches D4B- N D4BN Safety Limit Switch Snap-action contact with certified direct operation. mechanism (NC contacts only) added to enable contacts when faults occur, such as fused contacts.

More information

International, LLC. HMS/HLS/HNS Series Heavy Duty Limit Switches. Specifications. Features. Electrical Ratings HNS HLS HMS. Non-plug-in.

International, LLC. HMS/HLS/HNS Series Heavy Duty Limit Switches. Specifications. Features. Electrical Ratings HNS HLS HMS. Non-plug-in. HMS/HLS/HNS Series Heavy Duty Limit Switches Features Heavy duty zinc die cast body Conform to EN 6097-5-1, IEC 6097-5-1, UL508, NEMA250, CSA22.2 Standards Wide range of actuator available High repeatability

More information

Position switches FR series

Position switches FR series Position switches FR series Selection diagram 0 A 08 0-0 A A 0 A external rubber gasket external rubber gasket for electrical panels external rubber gasket external rubber gasket external rubber gasket

More information

Position switches FD series

Position switches FD series Position switches FD series Selection diagram 01 08 11 18 19 02 04 05 Ø 8 mm Ø, mm external rubber stainless steel stainless steel fibber glass rod gasket sphere sphere 51 52 5 56 41 42 adjustable lever

More information

Miniaturized limit switches

Miniaturized limit switches Miniaturized limit switches Selection diagram Actuators 04 0 06 Thermoplastic Bodies M3 Contact blocks NONC 1NO+1NC snap action Cable entry With screw 290 GENERAL CATALOGUE miniaturized limit switches

More information

Position switches FC series

Position switches FC series A Position switches FC series Selection diagram 0 08 8 9 0 0 0 Ø 8 mm Ø, mm external rubber stainless steel stainless steel fiber glass rod gasket sphere sphere 6 adjustable lever safety adjustable lever

More information

Applications Mill Mill Mill Mill. 9007T Convertible sequence. L100 Fixed sequence. Extra heavy duty contact ratings. Extra heavy duty contact ratings

Applications Mill Mill Mill Mill. 9007T Convertible sequence. L100 Fixed sequence. Extra heavy duty contact ratings. Extra heavy duty contact ratings Selection Guide Severe Duty Mill and Foundry Switches pplications Mill Mill Mill Mill Design 9007T Convertible sequence L0 Fixed sequence L14 Single Cable Pulls Fixed sequence L525 elt Conveyor Fixed sequence

More information

FL series position switches

FL series position switches FL series position switches Selection diagram 0 08 0 9 0 0 0 Ball Ø. External rubber Ball Ø 8 mm, mm, stainless Glass fibre rod gasket stainless steel steel Adjustable lever Adjustable safety lever Bistable

More information

3SE03 North American Limit Switches

3SE03 North American Limit Switches General Information Features Modular plug-in Prewired receptacle with pin connector Prewired cable Features UL Listed, CSA Certified. UL File: E47512 All Metal Captive Screws. Keyed, Four-Directional Head.

More information

ZCK-Y39 ZCK-Y49 ZCK-Y33 ZCK-Y34 ZCK-Y31 ZCK-D109 ZCK-D41 ZCK-D06 ZCK-M2H29 ZCK-M2H29

ZCK-Y39 ZCK-Y49 ZCK-Y33 ZCK-Y34 ZCK-Y31 ZCK-D109 ZCK-D41 ZCK-D06 ZCK-M2H29 ZCK-M2H29 ZCK-Y39 ZCK-Y43 ZCK-Y49 ZCK-Y41 ZCK-D239 ZCK-D23 ZCK-D59 ZCK-Y55 ZCK-Y54 ZCK-Y59 ZCK-D219 ZCK-D21 ZCK-D81 ZCK-D91 ZCK-Y91 ZCK-Y31 ZCK-Y33 ZCK-Y34 ZCK-Y81 ZCK-D029 ZCK-D02 ZCK-D05 ZCK-D109 ZCK-D41 ZCK-D06

More information

2.11. Limit Switches. Contents Description. Special Purpose Limit Switches. Special Purpose Limit Switches

2.11. Limit Switches. Contents Description. Special Purpose Limit Switches. Special Purpose Limit Switches Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800) 46-5480 www.cmafh.com.11 Product Description Features Special Purpose (Type F), Rotating Shaft (Type J),

More information

Heavy Duty, Industrial General Specifications XCKJ. Electrical Ratings Non-plug-in: A300 (AC), Q300 (DC)

Heavy Duty, Industrial General Specifications XCKJ. Electrical Ratings Non-plug-in: A300 (AC), Q300 (DC) Heavy Duty, Industrial General Specifications Rated Power Conforms to IEC 947-5-1, duty categories AC15 and DC13. emperature range -13 F to 158 F (-25 C to 7 ); optional -4 F (-4 C); +248 F (12 C). he

More information

Limit switches 0 ZCK E67 ZCK E23 ZCK E62. with contact, cable. entry for Pg 13, fi xed, 1 step (2) (3) ZCK JD3p, ZCK J1, J5, J6, J7, J9

Limit switches 0 ZCK E67 ZCK E23 ZCK E62. with contact, cable. entry for Pg 13, fi xed, 1 step (2) (3) ZCK JD3p, ZCK J1, J5, J6, J7, J9 Presentation Variable composition: standard bodies Thermoplastic roller lever plunger, 1 direction of actuation Steel roller lever plunger, 1 direction of actuation ZCK E1 ZCK E3 Side metal plunger Side

More information

Limit switches. Flameproof - Group IIC XCWD series. from the latest developments: modularity, compactness, a very broad range of actuators.

Limit switches. Flameproof - Group IIC XCWD series. from the latest developments: modularity, compactness, a very broad range of actuators. Sensors Limit switches Flameproof - Group IIC XCWD series from the latest developments: modularity, compactness, a very broad range of actuators. They are designed for intensive use and a very good repeatability.

More information

Safety Limit Switch

Safety Limit Switch Safety Limit Switch D4B-@N CSM_D4B-_N_DS_E_4_1 Snap-action contact with certified direct operation certification. Maintenance, seal, and resistance to shock increased and direct mechanism added. Three-conduit

More information

IEC Limit Switches Selection Guide

IEC Limit Switches Selection Guide IEC Limit Switches Selection Guide Limit Switches Selection Guide ABM Series ABP Series AAP Series Series ABM Series ABP Series AAP Series Prices start at Description Heavy duty IEC Double-insulated,

More information

XCKJ390559H29EX limit switch XCKJ - round rod Ø 6 mm - 2NC + NO - ATEX/IECEx

XCKJ390559H29EX limit switch XCKJ - round rod Ø 6 mm - 2NC + NO - ATEX/IECEx Characteristics limit switch XCKJ - round rod Ø 6 mm - 2NC + NO - ATEX/IECEx Main Range of product OsiSense ATEX D Series name Standard format Product or component type Limit switch Device short name XCKJ

More information

Contents. Limit Switches. Quick Selection Guide... page 6 2. Technical Definitions and Terminology... page 6 6

Contents. Limit Switches. Quick Selection Guide... page 6 2. Technical Definitions and Terminology... page 6 6 Contents.............. page 6 2 Technical Definitions and Terminology......................... page 6 6 Bulletin 801 General Purpose....... page 6 7 Bulletin 802A International Style Position Switches..................

More information

Limit Switch - Safety Type with pull button reset Plastic Body IP65 and Metal Body IP66

Limit Switch - Safety Type with pull button reset Plastic Body IP65 and Metal Body IP66 Limit Switch - Safety Type with pull button reset Plastic Body IP65 and Metal Body IP66 Double Insulation (for thermoplastic type) High mechanical resistant Degree of protection IP65 (thermoplastic) IP66

More information

3SE03 North American Limit Switches

3SE03 North American Limit Switches General Information Features Modular plug-in Prewired receptacle with pin connector Prewired cable Features UL Listed, CSA Certified. UL File: E47512 All Metal Captive Screws. Keyed, Four-Directional Head.

More information

9012G Pressure and 9016G Vacuum Switches

9012G Pressure and 9016G Vacuum Switches Selection Guide 90G and 906G Vacuum Switches Type of installation Control circuits Power circuits Applications Media controlled Type of operation Air, water, hydraulic oils, () gases, steam Fixed differential:

More information

IEC Limit Switches Selection Guide

IEC Limit Switches Selection Guide IEC Limit Switches Selection Guide Limit Switches Selection Guide ABM Series ABP Series AAP Series Series ABM Series ABP Series AAP Series Prices start at Description Heavy duty IEC Double-insulated,

More information

Switches with manual reset

Switches with manual reset Switches with manual reset Selection diagram 01-W 02-W 05-W 0-W -W -H0W 16-W 16-H0W Ø mm roller Ø mm roller Ø mm roller Ø mm roller 0-W 1-W 51-W 52-W 5-W 55-W -W adjustable lever safety adjustable lever

More information

Prewired position switches FF series

Prewired position switches FF series 2 Prewired position switches FF series Distributed buy Selection diagram 01 08 10 11 1 15 1 02 external rubber gasket external rubber gasket 1 52 54 55 56 5 ACTUATORS adjustable lever safety adjustable

More information

Selection diagram. Actuators. Body. Contact blocks. Cable entry A A S1 B B 13. Thermoplastic

Selection diagram. Actuators. Body. Contact blocks. Cable entry A A S1 B B 13. Thermoplastic Limit switches Selection diagram Actuators A A S B B 3 H G L LP LS Thermoplastic Body E I E2 I E4 I Contact blocks (standard) M2 ½ NPT NO+NC snap action NO+NC slow action 2 NO+NC slow action with overlapping

More information

Environment-Sealed Basic Switches

Environment-Sealed Basic Switches HoneywellSensing and Control 1-800-537-6945 USA 1-815-235-6847International 1-416-293-8111Canada 13 Environment-Sealed Basic Switches GENERAL INFORMATION SE and XE switches are the smallest environment-sealed

More information

Robust General-Purpose Limit Switch WL

Robust General-Purpose Limit Switch WL Robust General-Purpose Limit Switch WL Wide Selection of Two-Circuit Double-Break Limit Switches Rugged diecast housing High mechanical strength Oiltight, waterproof, dustproof construction Overtravel

More information

Safety switches for hinged doors

Safety switches for hinged doors 4 Safety switches for hinged doors Selection diagram FR FM FX FZ FK 5 18 7 9 snap action overlapped CONTACT BLOCKS 20 21 22 33 34 1NO+ CONDUIT ENTRIES Threaded conduit entries (standard) With cable gland

More information

Limit Switch - Prewired Type Metal Body

Limit Switch - Prewired Type Metal Body Limit Switch - Prewired Type Metal Body Sealed with epoxy resin al the base of the box Degree of protection IP67 Thermoplastic material or diecast zinc alloy body Positive Opening Operation Minimum Actuation

More information

the Interactive Catalog

the Interactive Catalog Interactive Catalog Supplements Catalog PDFs If you need detailed product information, or help choosing the right product for your application, see our Interactive Catalog Use the Interactive Catalog to

More information

LS Series Limit Switches. Short Form Catalogue AC1300 ABB

LS Series Limit Switches. Short Form Catalogue AC1300 ABB Short Form Catalogue LS Series Limit Switches AC ABB LS Series Limit Switches Foot Switches Contents Panorama... 2 Limit Switches - Plastic Casing and Metal Casing... 12 Safety Limit Switches - Plastic

More information

Safety Switches & Operator Controls

Safety Switches & Operator Controls Safety Switches & Operator Controls Contents Selection Guide H-2 Safety Limit Switches Plastic D4N H-4 D4N- R H-12 Safety Limit Switches Metal D4B- N H-13 D4F H-13 Safety Selector Switch A22TK H-14 Enabling

More information

MICRO SWITCH Heavy-Duty Limit Switch (Stainless Steel) HDLS LS2 Series

MICRO SWITCH Heavy-Duty Limit Switch (Stainless Steel) HDLS LS2 Series MICRO SWITCH Heavy-Duty Limit Switch (Stainless Steel) HDLS LS2 Series DESCRIPTION When the application requires an industrial grade limit switch where wet, dust, or corrosive environments may be present,

More information

Limit switches. Presentation. OsiSense XC Special For hoisting and material handling applications XCR. b XCR

Limit switches. Presentation. OsiSense XC Special For hoisting and material handling applications XCR. b XCR Presentation For hoisting and material handling applications XCR b XCR v With head for rotary movement operators, spring return to off position 1 contact actuation position per direction Page 326/6 v With

More information

Limit Switches - Limit Type (PS31L) Plastic Body IP65

Limit Switches - Limit Type (PS31L) Plastic Body IP65 Limit Switches - Limit Type (PSL) Plastic Body IP65 Double Insulation Degree of protection IP65 Reinforced UL-V thermoplastic fiber-glass body Positive Opening Operation Minimum Actuation Force/Torque

More information

Limit Switches 1-1 thru Safety Switches 2-1 thru Index 3-1

Limit Switches 1-1 thru Safety Switches 2-1 thru Index 3-1 Limit Switches - thru -6 Safety Switches - thru -0 Index 3-3 i Industrial Limit Switches Basic Technical Concepts / 8385 / 83853 Miniature Industrial Limit Switches, Positive Opening /4 8386 Industrial

More information

Presentation, Application Severe Duty Limit Switches Mill and Foundry Switches Conforming to NEMA A600 and UL508

Presentation, Application Severe Duty Limit Switches Mill and Foundry Switches Conforming to NEMA A600 and UL508 Presentation, pplication Severe uty Limit Switches 0 onforming to NEM 600 and UL508 escription 9007T Mill Switches Use the 9007T Mill switches instead of other limit switches in the following applications:

More information

Selection diagram. Actuators. Body. Contact blocks. Cable entry A A S1 B B 13. Thermoplastic

Selection diagram. Actuators. Body. Contact blocks. Cable entry A A S1 B B 13. Thermoplastic Limit switches Selection diagram Actuators A A S B B G L LP LS Thermoplastic Body E0 I E20 I E40 I Contact blocks (standard) M20 ½ NPT 00 NO+NC snap action 0 NO+NC slow action 02 NO+NC slow action with

More information

SPECIAL DUST EXPLOSIVES ATMOSPHERES

SPECIAL DUST EXPLOSIVES ATMOSPHERES SPECIAL DUST EXPLOSIVES ATMOSPHERES Explosive atmospheres Main sectors of activity subject to a higher risk of explosion or fire Flour mills Wood and aluminium workshops A reference for installations in

More information

Limit switches Osiswitch Classic Metal, conforming to CENELEC EN 50041, type XCK J Fixed or plug-in body Variable composition: standard bodies

Limit switches Osiswitch Classic Metal, conforming to CENELEC EN 50041, type XCK J Fixed or plug-in body Variable composition: standard bodies Presentation Metal, conforming to CENELEC EN 41, type XCK J Variable composition: standard bodies ZCKE1 ZCKE ZCKE63 ZCKE64 ZCKE6 ZCKE8 ZCKE6 ZCKE67 ZCKE69 ZCKE61 ZCKE66 ZCKE619 ZCKJ1D, JD, J6D, J7D ZCKJ8D

More information

Safety switches for hinged doors

Safety switches for hinged doors 4C Safety switches for hinged doors Selection diagram CONTACT BLOCKS 18 7 9 20 overlapped 1NO+ FD FL FC 21 22 33 34 2NO+1NC 3NC CONDUIT ENTRIES Threaded conduit entries (standard) With cable gland assembled

More information

D4B-N. uce. Safety Limit Switch. Positive Action Limit Switches with Direct Drive Contacts for Critical Switching Applications

D4B-N. uce. Safety Limit Switch. Positive Action Limit Switches with Direct Drive Contacts for Critical Switching Applications Safety Limit Switch Positive Action Limit Switches with Direct Drive Contacts for Critical Switching Applications H Snap-action contact for accurate switching with safe operation via direct drive positive

More information

Prewired position switches FF series

Prewired position switches FF series 2 Prewired position switches FF series Selection diagram 01 08 10 11 1 15 1 02 external rubber gasket external rubber gasket 1 52 54 55 56 5 ACTUATORS adjustable lever safety adjustable lever 41 45 46

More information

Presentation. Limit switches. b XC2J. v With head for linear movement (plunger) with 1 cable entry. v With head for rotary movement (lever)

Presentation. Limit switches. b XC2J. v With head for linear movement (plunger) with 1 cable entry. v With head for rotary movement (lever) Presentation b XCJ with cable entry v With head for linear movement (plunger) v With head for rotary movement (lever) General characteristics Environment characteristics Conformity to standards Standard

More information

Available as assembled switches or components. E50ANR1 with E50KL200 Lever. Conduit, cable and connector wiring options

Available as assembled switches or components. E50ANR1 with E50KL200 Lever. Conduit, cable and connector wiring options Modular Plug-In Limit Switches E50 Series Available as assembled switches or components E50KL200 Easy to Install High Reliability Low Maintenance Modular to Reduced Inventory E50ANR1 with E50KL200 Lever.

More information

Limit Switches - Limit Type Plastic Body IP65

Limit Switches - Limit Type Plastic Body IP65 Limit Switches - Limit Type Plastic Body IP65 Double Insulation Degree of protection IP65 Reinforced UL-V thermoplastic fiber-glass body Positive Opening Operation Minimum Actuation Force/Torque Minimum

More information

Non-illuminated Push Buttons

Non-illuminated Push Buttons Non-illuminated Push Buttons 3 Accessories for push buttons Lockout attachment Contact block kits Lens kits Wobblestick kit Push Button Cap Interchangeable, snap-in design Protective caps 9 colors: red,

More information

HL (AZH) LIMIT SWITCHES

HL (AZH) LIMIT SWITCHES COMPACT SIZE LIMIT SWITCHES LIMIT SWITCHES U L PRODUCT TYPE 1. Limit Switches Actuator Type Push plunger Roller plunger Cross roller plunger Panel mount push plunger Panel mount roller plunger Panel mount

More information

Model Number Structure

Model Number Structure Small Sealed Switch D4E-@N Slim and Compact Switch with Better Seal and Ensuring Longer Service Life than D4E Flat springs with an improved lever ratio of the built-in switch ensure smooth snap action

More information

Selection diagram. Actuators. Body. Contact blocks. Cable entry A A S1 B B 13. Thermoplastic

Selection diagram. Actuators. Body. Contact blocks. Cable entry A A S1 B B 13. Thermoplastic Limit switches Selection diagram Actuators A A S B B G L LP LS Thermoplastic Body E I E2 I E4 I Contact blocks (standard) M2 ½ NPT NO+NC snap action NO+NC slow action 2 NO+NC slow action with overlapping

More information

Safety switches with separate actuator

Safety switches with separate actuator Safety switches with separate actuator Selection diagram VF KEYD VF KEYD1 VF KEYD VF KEYD VF KEYD5 ACTUATORS VF KEYD6 VF KEYD7 VF KEYD8 VF KEYD10 VF KEYD11 FR FX FK FW 5 6 7 11 1 14 NC NC slow action slow

More information

Limit Switches - Limit Type (PS42L) Plastic Body IP65

Limit Switches - Limit Type (PS42L) Plastic Body IP65 Limit Switches - Limit Type (PS42L) Plastic Body IP65 Double Insulation Degree of protection IP65 Reinforced UL-V thermoplastic fiber-glass body Positive Opening Operation Minimum Actuation Force/Torque

More information

Commercial Pressure and Float Switches for Power Circuits Catalog 9034CT9701R01/11 Class 9013, 9036, 9037, 9038

Commercial Pressure and Float Switches for Power Circuits Catalog 9034CT9701R01/11 Class 9013, 9036, 9037, 9038 Commercial Pressure and Float Switches for Power Circuits Catalog 9034CT9701R01/11 Class 9013, 9036, 9037, 9038 TM Table of Contents Table of Contents SELECTION GUIDE PUMPTROL COMMERCIAL PRESSURE SWITCHES...

More information

Limit Switches - Limit Type Plastic Body IP65

Limit Switches - Limit Type Plastic Body IP65 Limit Switches - Limit Type Plastic Body IP65 Double Insulation Degree of protection IP65 Reinforced UL-V thermoplastic fiber-glass body Positive Opening Operation Minimum Actuation Force/Torque Minimum

More information

Compact Limit Switches

Compact Limit Switches Compact AEMG Series Compact Die-cast metal housings 3-meter cable on all units N.O. and N.C. contact on all units Compact size with standard 5 mm hole spacing Wide offering of head actuators Epoxy resin-filled

More information

ED SERIES SAFETY LIMIT SWITCH

ED SERIES SAFETY LIMIT SWITCH Description The ED series safety limit switches conform to EN 547 and have been developed to provide a range of options including plastic cases in various sizes, a choice of snap acting, slow break/make

More information

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

For full product information, visit  Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page. Safety Interlock Switches D4S-N D4SN For full product information, visit www.sti.com. Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page. Slim Safety Door Switches with

More information

Pre wired limit switches

Pre wired limit switches Pre wired limit switches Selection diagram Actuators A B B 9 BL Thermoplastic Bodies E7 I s NO+NC snap action NO+NC slow action Cable entry 4 or 5 pole PVC sheath cable (standard) M connector AMP connector

More information

Gross Automation (877)

Gross Automation (877) Limit Switches Carlo Gavazzi broadens its leading range of products for the industrial automation world, with the new and complete range of mechanical limit and safety switches. These robust switches provide

More information

Class 9038 Type A Mechanical Alternator, Open Tank

Class 9038 Type A Mechanical Alternator, Open Tank Selection Guide Float Switches Class 9038 Type A Mechanical Alternator, Open Tank Type of Installation Product Features Horsepower rated 4-pole switch Standard action contacts close on liquid rise Reverse

More information

Safety rope switch with reset for emergency stop

Safety rope switch with reset for emergency stop Safety rope switch with reset for emergency stop Selection diagram 8 8 83 ACTUATORS ACTUATORS CONTACT BLOCKS 18 9 21 1NO+,, FP FD FL FC 22 33 34,, CONDUIT ENTRIES Threaded conduit entries (standard) With

More information

MICRO SWITCH Solenoid Safety Interlock Switches GKL/R Series Issue 2. Datasheet

MICRO SWITCH Solenoid Safety Interlock Switches GKL/R Series Issue 2. Datasheet MICRO SWITCH Solenoid Safety Interlock Switches GKL/R Series DESCRIPTION MICRO SWITCH GKL/R Series switches are a heavy-duty key operated solenoid safety interlock switch incorporating a key trapping mechanism.

More information

SL1Series. Compact Horizontal Limit Switches

SL1Series. Compact Horizontal Limit Switches Compact Horizontal Limit Switches SL1Series Mechanical life of 0 million operations. Robust long-life and maintenance-free compact horizontal-type limit switches with IP67 seal. Mechanical life exceeds

More information

Safety-door Switch D4NS. Model Number Structure. Model Number Legend

Safety-door Switch D4NS. Model Number Structure. Model Number Legend Safety-door Switch D4NS Multi-contact, Labor-saving, Environmentfriendly, Next-generation Safety-door Switch Lineup includes MBB models and three contact models with 2NC/1NC and 3NC contact forms in addition

More information

Selector Push Button Cat. No. 800T-K2AAXX. a b c d e f g Right Left Right Left. d, e, f, g. Contact Blocks. No contacts on operator

Selector Push Button Cat. No. 800T-K2AAXX. a b c d e f g Right Left Right Left. d, e, f, g. Contact Blocks. No contacts on operator NEMA Push Specifications 800T/H 30.5 mm Push s Selector Push Devices (Bul. 800T only) Selector Push Cat. No. 800T-K2AAXX 800T KD 2 G J D E a b c d e f g Right Left Right Left Blank C K KA KB KC KD KE a

More information

D4BS. Safety-door Switch. Model Number Structure. Switch D4BS - S Operation Key D4BS - K. Ordering Information

D4BS. Safety-door Switch. Model Number Structure. Switch D4BS - S Operation Key D4BS - K. Ordering Information Safety-door Switch Safety-door Switch s Special Operation Key Directly Pulls Apart the Contacts from Each Other and Contributes to the Safety of the Production Site Conforms to EN (TÜV) standards corresponding

More information

the Interactive Catalog

the Interactive Catalog Interactive Catalog Supplements Catalog PDFs If you need detailed product information, or help choosing the right product for your application, see our Interactive Catalog Use the Interactive Catalog to

More information

Position Switches Series 8074/2

Position Switches Series 8074/2 www.stahl.de > Ex e metal enclosure > Operating temperature range -40 C... +70 C > Dimensions and characteristic values according to EN 50041 > Degree of protection IP66 > Extensive assortment of actuators,

More information

Limit Switches Schneider Electric All Rights Reserved. Limit Switches 10/02

Limit Switches Schneider Electric All Rights Reserved. Limit Switches 10/02 Steven Engineering-0 Ryan Way-South San Francisco, CA 9080-70-Main Office:(0)88-900-Outside ocal Area:(800)8-900-www.stevenengineering.com 00/00 Severe Duty Mill and Foundry and Specifications 00/00 Severe

More information

Valve Position Monitors

Valve Position Monitors CONTROLS Valve Position Monitors EX Series for Hazardous Locations APL Series NEMA 4, 4X CONTROLS Triac APL Series Limit Switches The Triac APL Series Limit Switches feature high quality, easy to use multiple

More information

Limit Switches with Positive Opening Mechanism

Limit Switches with Positive Opening Mechanism Limit Switches with Positive Opening Mechanism LJA Series Positive opening mechanism Snap action limit switches with positive opening mechanism enables general industrial machines to comply with EC directives

More information

Switches. SERIES FEATURE ACTUATION MAX RATING SEAL RATING MOUNTING CIRCUITRY 115VAC, 28VDC)

Switches. SERIES FEATURE ACTUATION MAX RATING SEAL RATING MOUNTING CIRCUITRY 115VAC, 28VDC) SWITCH SELECTION GUIDE Toggle Switches SERIES FEATURE ACTUATION MAX RATING SEAL RATING MOUNTING CIRCUITRY (Resistive @ 115VAC, 28VDC) T1 2 or 3 Position, Momentary, 8A MIL-PRF-83731 15/32" or 1/4" dia.

More information

O bloco de contato XESP2031 é utilizado no corpo ZCKJ4* / ZCKJ404 é tem o seu acionamento escalonado, ou seja:

O bloco de contato XESP2031 é utilizado no corpo ZCKJ4* / ZCKJ404 é tem o seu acionamento escalonado, ou seja: O bloco de contato XESP1 é utilizado no corpo ZCKJ é tem o acionamento instantâneo de todos os seus contato (NA+NF) ao mesmo tempo independente do lado de atuação do cabeçote. O bloco de contato XESP31

More information

Square D General Purpose Relays

Square D General Purpose Relays Square D General Purpose Relays Class 0R plug-in relays 0RS (SPDT) 0RS (DPDT) 0RS3 (3PDT) 0RS (PDT) Catalog 0 Contents Class 0R plug-in relays bbspecifications....................................................

More information

Limit Switch D4D- N. Small, Economical Switch Featuring a Positive Opening Mechanism and Conforming to the CE Mark

Limit Switch D4D- N. Small, Economical Switch Featuring a Positive Opening Mechanism and Conforming to the CE Mark Limit Switch Small, Economical Switch Featuring a Positive Opening Mechanism and Conforming to the CE Mark Features positive opening mechanism (NC contacts only) that opens contacts, thus preventing faulty

More information

Microswitches MK series

Microswitches MK series D Microswitches MK series Introduction Microswitches of MK series have been developed in order to add new features to traditional and tested microswitches of Pizzato Elettrica (cross-reference at page

More information

Microswitches M series

Microswitches M series Microswitches M series Technical data Housing Made of glass-reinforced polymer, self-extinguishing, shock-proof thermoplastic resin. Protection degree: IP40 (with protection art. VF C0) IP0 (with protection

More information

Limit switches. Presentation. OsiSense XC Special For hoisting and material handling applications, type XCR. b XCR

Limit switches. Presentation. OsiSense XC Special For hoisting and material handling applications, type XCR. b XCR Presentation type XCR b XCR v With head for rotary movement operators, spring return to off position contact actuation position per direction Page / v With head for rotary movement operators, stay put

More information

LJASeries. Limit Switches with Positive Opening Mechanism

LJASeries. Limit Switches with Positive Opening Mechanism Limit Switches with Positive Opening Mechanism LJASeries Snap action limit switches with positive opening mechanism enables general industrial machines to comply with EC directives and to acquire CE marking.

More information

LR-LX-LK-LW Safety Switches with separate actuator

LR-LX-LK-LW Safety Switches with separate actuator LR-LX-LK-LW Safety Switches with separate actuator Technopolymer housing, from one to three conduit entries Protection degree IP67 15 contact blocks available 8 stainless steel actuators available Versions

More information

Mipco Connections for Refrigerated Containers. No One Does It Like Mipco. The Mipco. Advantage. Reliability. Safety. Easy Installation & Service

Mipco Connections for Refrigerated Containers. No One Does It Like Mipco. The Mipco. Advantage. Reliability. Safety. Easy Installation & Service No One Does It Like Mipco Mipco Interlocked Reefer Power Outlets are used extensively in port terminals and shipboard applications to provide a safe, watertight electrical connection for refrigerated containers.

More information

Miniature microswitches - Positive break

Miniature microswitches - Positive break 1 Miniature microswitches - Positive break 81607 Coil spring snap-action mechanism with wiping contacts Positive opening action according to IEC 6097-5-1 Annex K atings from 10 ma Vc to 6 A 250 Va Very

More information

Operation Key D4BS - K Head Mounting Direction F: Four mounting directions possible (front-side mounting at shipping)

Operation Key D4BS - K Head Mounting Direction F: Four mounting directions possible (front-side mounting at shipping) Safety-door Switch D4BS The Special Activates a Direct Opening Mechanism to Open the Contacts and Shut Off Control Circuits when Protective Doors Are Opened on Machine Tools or Other Equipment CSM_D4BS_DS_E_6_1

More information

800 T FX 1 A1. Color Cap. No cap 1 Green 2 Black 3 Orange 4 Grey 5 White 6 Red 7 Blue 9 Yellow. Contact Block(s) Operator Position.

800 T FX 1 A1. Color Cap. No cap 1 Green 2 Black 3 Orange 4 Grey 5 White 6 Red 7 Blue 9 Yellow. Contact Block(s) Operator Position. 2-Position Push-Pull and Push-Pull/Twist Release Devices, Non-Illuminated Note: A jumbo or large legend plate is recommended, if space allows. 2-Position Push-Pull Cat. No. 800T-F6D4 2-Position Metal Push-Pull

More information

Limit Switches - Safety Type Plastic Body IP65 and Metal Body IP66

Limit Switches - Safety Type Plastic Body IP65 and Metal Body IP66 Limit Switches - Safety Type Plastic Body IP65 and Metal Body IP66 Product Description They are developed in order to be used for following operations: For monitoring and protection of industrial machines,

More information

Limit Switches - Limit Type (PS21L) Metal Body IP66

Limit Switches - Limit Type (PS21L) Metal Body IP66 Limit Switches - Limit Type (PS21L) Metal Body IP66 High mechanical resistance Degree of protection IP66 Zinc alloy (Zamack) or aluminium body Positive Opening Operation Minimum Actuation Force/Torque

More information

HL (AZH) Limit Switches

HL (AZH) Limit Switches COMPACT SIZE LIMIT SWITCHES HL (AZH) Limit Switches Wide selections of actuators, terminals and bodies to meet any application Excellent environmental resistance Die casting caseiec IP67 Plastic caseiec

More information

XMLB300D2C11 pressure switch XMLB 300 bar - adjustable scale 2 thresholds - 1 C/O

XMLB300D2C11 pressure switch XMLB 300 bar - adjustable scale 2 thresholds - 1 C/O Characteristics pressure switch XMLB 300 bar - adjustable scale 2 thresholds - 1 C/O Complementary Possible differential minimum at low setting Possible differential minimum at high setting Maximum permissible

More information